Loading...
HomeMy WebLinkAboutComments-response 7.28.2026Author Name Author Email Author Phone No.: Katie Saurey katie.saurey@rexburg.org 208-372-2167 Stan Crittenden stan.crittenden@rexburg.org 208-372-2314 Joel Gray joel.gray@rexburg.org 208-372-2331 Description : Address : Approx 601 University Blvd Application Type : Document Filename : INFRASTRUCTURE 5.7.26 - 26-00537 - Tamana Fields - Approx 600 University Blvd - Plat.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments C - 4.0 P Callout Joel Gray : PW Open 4 Secondary Irrigation can not be in street. C - 4.0 P Free Text Joel Gray : PW Open 4 No streetlight shown. C - 4.0 P Callout Joel Gray : PW Open 4 Entrance not allowed per Purchase Agreement. Only 4 connections allowed to University Blvd. C - 4.0 P Callout Joel Gray : PW Open 4 Back of sidewalk must be at ROW Line. C - 4.0 P Callout Joel Gray : PW Open 4 Bridge widening Street and sidewalk must be completed to end east of Lot 2. C - 4.0 P Callout Joel Gray : PW Open 4 Water line must be 12" line. C - 4.0 P Callout Joel Gray : PW Open 4 Stub to East not required. C - 4.0 P Callout Joel Gray : PW Open 4 Water line must be 12" line. C - 4.0 P Callout Joel Gray : PW Open 4 8" water stub out for future looping. C - 4.0 P Free Text Joel Gray : PW Open 4 No water or sewer stubs to this lot. C - 4.0 P Free Text Joel Gray : PW Open 4 If known, insert sewer service for Lot 1. C - 4.0 P Callout Joel Gray : PW Open 4 Fire hydrant must be protected from damage. C - 4.0 P Callout Joel Gray : PW Open 4 Valve required. # 26-00537 Plat Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 05-27-2026 10:38:18 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments C - 4.0 P Callout Joel Gray : PW Open 4 How are others to continue this line safely? C - 4.0 P Free Text Joel Gray : PW Open 4 TIS recommendations must be addressed.. C - 5.0 G Callout Joel Gray : PW Open 5 Must have slope. C - 5.1 G Callout Joel Gray : PW Open 6 Minimum 1% slope. C - 5.1 G Callout Joel Gray : PW Open 6 0.3% minimum. Report Date: 05-27-2026 10:38:18 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by PDF Generator API