C - 4.0 P Callout Joel Gray : PW Open 4 Secondary Irrigation can not be in street.
C - 4.0 P Free Text Joel Gray : PW Open 4 No streetlight shown.
C - 4.0 P Callout Joel Gray : PW Open 4 Entrance not allowed per Purchase Agreement. Only 4
connections allowed to University Blvd.
C - 4.0 P Callout Joel Gray : PW Open 4 Back of sidewalk must be at ROW Line.
C - 4.0 P Callout Joel Gray : PW Open 4 Bridge widening Street and sidewalk must be completed to
end east of Lot 2.
C - 4.0 P Callout Joel Gray : PW Open 4 Water line must be 12" line.
C - 4.0 P Callout Joel Gray : PW Open 4 Stub to East not required.
C - 4.0 P Callout Joel Gray : PW Open 4 Water line must be 12" line.
C - 4.0 P Callout Joel Gray : PW Open 4 8" water stub out for future looping.
C - 4.0 P Free Text Joel Gray : PW Open 4 No water or sewer stubs to this lot.
C - 4.0 P Free Text Joel Gray : PW Open 4 If known, insert sewer service for Lot 1.
C - 4.0 P Callout Joel Gray : PW Open 4 Fire hydrant must be protected from damage.
C - 4.0 P Callout Joel Gray : PW Open 4 Valve required.
# 26-00537
Plat
Please digitally re-submit all pages of the plan set in response to requested revisions
for our next review cycle, with noted items resolved.
Report Date: 05-27-2026 10:38:18
Approval of plans does not constitute approval of variance from code
Page 1 of 2
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
C - 4.0 P Callout Joel Gray : PW Open 4 How are others to continue this line safely?
C - 4.0 P Free Text Joel Gray : PW Open 4 TIS recommendations must be addressed..
C - 5.0 G Callout Joel Gray : PW Open 5 Must have slope.
C - 5.1 G Callout Joel Gray : PW Open 6 Minimum 1% slope.
C - 5.1 G Callout Joel Gray : PW Open 6 0.3% minimum.
Report Date: 05-27-2026 10:38:18