HomeMy WebLinkAbout2 HOUR SEPARATION WALL - 22-00481 - Vorp Energy - Storage2X EXTERIOR WALL OF EXISTING BUILDING
NEW METAL WALL GIRTS
FURRING CHANNELS 24" O.C.
ATTACHED TO GIRTS WITH (2) 3/8"
LONG, TYPE S-12 PANHEAD
SCREWS AT EACH GIRT
BASE LAYER: 5/8" TYPE X GYPSUM PANEL
APPLIED AT RIGHT ANGLES TO EACH FURRING
STRIP W/ 1" TYPE S SCREWS @ 24" O.C.
FACE LATER: 5/8" TYPE X GYPSUM PANEL
APPLIED AT RIGHT ANGLES TO EACH FURRING
STRIP W/ 1-5/8" TYPE S SCREWS @ 12" O.C.
BASE LAYER: 5/8" TYPE X GYPSUM PANEL
APPLIED AT RIGHT ANGLES TO EXISTING
TUFF RIB METAL PANEL @ 24" O.C. W/ 1" TYPE
S SCREWS @ 24" O.C.
FACE LATER: 5/8" TYPE X GYPSUM PANEL
APPLIED AT RIGHT ANGLES TO EXISTING
TUFF RIB METAL PANEL @ 24" O.C. W/ 1-5/8"
TYPE S SCRES @ 12" O.C.
ASSEMBLY GA FILE
NO. WP9205
NEW STEEL EXTERIOR WALL PANEL GABLE
EXTEND GYPSUM PANELS MIN. 18" O.C.
BEYONE TOP OF EXISTING ROOF
2 HOUR
SEPARATION
WALL
EXISTING SIDENEW ADDITION SIDE