Loading...
HomeMy WebLinkAboutSITE PLAN - Westmark Credit Union - New Building (1)101 ROOM NAME A101 1 1 A101 1 ENLARGED DETAIL WALL SECTION BUILDING SECTION DETAIL SECTION 1 INTERIOR ELEVATION DOOR & INTERIOR WINDOW TAG WALL TAG ROOM IDENTIFICATION EXTERIOR WINDOW & LOUVER TAG EXISTING DOOR DOOR FULL HEIGHT PARTITION PARTIAL HEIGHT PARTITION NOTE KEY FLOOR ELEVATION 1001 1 REVISION CLOUD & TAG PLAN ELEVATION50'-6" WORKING POINTWP A101 SIM A1 A2 A3 A4 DIMENSION TO THE FACE OF FRAMING AT NEW CONSTRUCTION, TYP. DIMENSION TO THE FACE OF FINISH AT EXISTING CONSTRUCTION DIMENSION TO THE FACE OF FINISH 1 EXISTING PARTITION ASI-001 11/14/2025 1 A101 1 A101 NAME ELEVATION AAP AREA ALARM PANEL ACP ACOUSTICAL CEILING PANEL AFF ABOVE FINISH FLOOR CI CONTINUOUS INSULATION CJ CONTROL JOINT CL CENTERLINE CLL CONTRACT LIMIT LINE CLR CLEAR ETR EXISTING TO REMAIN EJ EXPANSION JOINT FEC FIRE EXTINGUISHER CABINET GA GAUGE HR HOUR MAX MAXIMUM MIN MINIMUM MIR MIRRORED ARCHITECTURAL SYMBOLS NIC NOT IN CONTRACT NPS NOMINAL PIPE SIZE NR NOT REQUIRED OC ON CENTER OD OUTSIDE DIAMETER OFCI OWNER FURNISHED CONTRACTOR INSTALLED OFOI OWNER FURNISHED OWNER INSTALLED OPP OPPOSITE RD ROOF DRAIN SF SQUARE FOOT SIM SIMILAR SQ IN SQUARE INCHES TYP TYPICAL UON UNLESS OTHERWISE NOTED VFCI VENDOR FURNISHED CONTRACTOR INSTALLED ZVB ZONE VALVE BOX ABBREVIATIONS CONTRACT LIMIT LINE MATCHLINE AREA NOT IN CONTRACT (NIC) ALTERNATE WORK SCOPE AS INDICATED DATE: JOB NUMBER: WARNING: IT IS A VIOLATION FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF A DOCUMENT BEARING THE SEAL OF AN ARCHITECT OR ENGINEER IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. STAMP CONSTRUCTION TYPE: OCCUPANCY TYPE: SPRINKLER PROTECTION: TOTAL AREA OF PROJECT (GSF): (T B D ) T R A P P E R ' S L O O P R O A D , R E X B U R G , I D 8 3 4 4 0 08/12/2026 2026-001 (TBD) TRAPPER'S LOOP ROAD, REXBURG, ID 83440 WESTMARK CREDIT UNION WE S T M A R K C R E D I T U N I O N NEW CONSTRUCTION FOR G001 V-B B-BUSINESS NON-SPRINKLERED 2,712 DRAWING LIST GENERAL G001 COVER SHEET G002 CODE COMPLIANCE CHARTS G003 CODE COMPLIANCE CHARTS G004 ENERGY CODE COMPLIANCE G005 CODE COMPLIANCE PLAN G006 ARCHITECTURAL SITE PLAN CIVIL C0.1 COVER SHEET C0.2 EXISTING CONDITIONS C1.1 SITE PLAN C2.1 UTILITY PLAN C3.1 GRADING & DRAINAGE PLAN C4.1 PAVING DETAILS C4.2 STORMWATER PLAN & MISC. DETAILS C4.3 UTILITY DETAILS LANDSCAPE L100 LANDSCAPE PLAN L150 NOTES & DETAILS STRUCTURAL S1.0 GENERAL STRUCTURAL NOTES S1.1 SPECIAL INSPECTIONS S1.2 TYPICAL DETAILS S1.3 TYPICAL DETAILS S2.0 FOUNDATION PLAN S2.1 ROOF FRAMING PLAN S2.2 ITM CANOPY FOUNDATION AND ROOF FRAMING PLAN S3.0 FOUNDATION DETAILS S4.0 ROOF FRAMING DETAILS S4.1 ROOF FRAMING PLAN ARCHITECTURAL A100 INTERIOR & EXTERIOR ASSEMBLIES A101 FLOOR PLANS A102 ITM CANOPY PLANS & DETAILS A151 REFLECTED CEILING PLANS A160 INTERIOR FINISH PLANS & SCHEDULE A200 EXTERIOR ELEVATIONS A250 TYPICAL MOUNTING HEIGHTS & ELEVATIONS A251 CASEWORK DETAILS A252 ENLARGED PLANS & INTERIOR ELEVATIONS A301 BUILDING SECTIONS A311 WALL SECTIONS A650 DOORS & BORROWED LITES A651 WINDOWS & STOREFRONTS A700 ROOF PLAN & DETAILS A900 FURNITURE & EQUIPMENT PLANS MECHANICAL M0.0 MECHANICAL COVER SHEET M0.1 MECHANICAL SCHEDULES M0.2 MECHANICAL SPECIFICATIONS M1.1 MECHANICAL PLAN - LEVEL 1 M5.0 MECHANICAL DETAILS PLUMBING P0.0 PLUMBING COVER SHEET P0.1 PLUMBING SCHEDULES P0.2 PLUMBING SPECIFICATIONS P1.1 WASTE & VENT PLAN - LEVEL 1 P2.1 WATER PLAN - LEVEL 1 P5.0 PLUMBING DETAILS AND DIAGRAMS ELECTRICAL E00 ELECTRICAL SYMBOLS & ABBREVIATIONS E01 RISER AND DETAILS E02 LIGHTING & PANEL SCHEDULES E03 ENERGY & COMPLIANCE FORMS E11 LIGHTING PLAN LEVEL 1 E21 POWER PLAN LEVEL 1 E31 MECHANICAL POWER PLAN LEVEL 1 E41 LOW VOLTAGE PLAN LEVEL 1 E51 POWER SITE PLAN 1 ALL WORK IS NEW UNLESS NOTED AS EXISTING. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 2 ANY DISCREPANCY CONTAINED WITHIN ANY OF THE DOCUMENTS SHALL BE UNDERSTOOD TO MEAN THAT THE GREATER QUANTITY AND OR THE BETTER QUALITY SHALL BE PROVIDED IN THE FAVOR OF THE OWNER. 3 DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. 4 NOTES ON ONE DETAIL OR DRAWING APPLY TO ALL SIMILAR DETAILS AND DRAWINGS. 5 DIMENSIONS NOTED "EQ" ARE EQUAL TO EACH OTHER ONLY IF THEY ARE ON THE SAME DIMENSION STRING AND IN THE SAME ROW. GENERAL ARCHITECTURAL NOTES NOTE: RENDERINGS ARE PROVIDED FOR REFERENCE ONLY AND ARE NOT CONSIDERED PART OF THE CONTRACT DOCUMENTS. REFER TO DRAWINGS AND SPECIFICATIONS FOR ALL CONSTRUCTION REQUIREMENTS. 8/14/2026 NOTE: NOT ALL MAY APPLY LOCATION OF EXITS EXIT ACCESS TRAVEL DISTANCE (EATD): DISTANCE TO EXITS FROM THE MOST REMOTE POINT IN THE MOST REMOTE ROOM ON THE FLOOR COMMON PATH OF EGRESS TRAVEL (CPET) E ENCLOSED EXIT/ EXIT TO EXTERIOR HE HORIZONTAL EXIT EA EXIT ACCESS REMOTENESS OF EXITS D2 = xxx FEET D1 = xxx FEET ED EXIT DISCHARGE EXIT TO EXIT (D1) BUILDING DIAGONAL (D2) EATD = xxx FEET CPET = xxx FEET FIRE EXTINGUISHER FEBRACKET CABINET CONTRACT LIMIT LINE DEAD END CORRIDOR (DE)DE = xxx FEET 2 HOUR FIRE WALL - EXISTING FW-2HR-E 2 HOUR FIRE WALL FW-2HR 2 HOUR FIRE BARRIER - EXISTING FB-2HR-E 2 HOUR FIRE BARRIER FB-2HR 3 HOUR FIRE BARRIER - EXISTING 3 HOUR FIRE BARRIER FB-3HR-E FB-3HR SE-2HR-E SE-2HR 2 HOUR SHAFT/STAIR ENCLOSURE - EXISTING 2 HOUR SHAFT/STAIR ENCLOSURE 1 HOUR FIRE BARRIER - EXISTING FB-1HR-E 1 HOUR FIRE BARRIER FB-1HR 1/2 HOUR FIRE PARTITION - EXISTING 0 HOUR SMOKE PARTITION - EXISTING SP-0HR 1/2 HOUR FIRE PARTITION FP-1/2HR-E SP-0HR-E 0 HOUR SMOKE PARTITION 1 HOUR SHAFT/STAIR ENCLOSURE - EXISTING 1 HOUR SHAFT/STAIR ENCLOSURE SE-1HR-E SE-1HR 1 HOUR FIRE PARTITION - EXISTING 1 HOUR FIRE PARTITION FP-1HR-E FP-1HR 1 HOUR SMOKE BARRIER - EXISTING 1 HOUR SMOKE BARRIER SB-1HR-E SB-1HR FP-1/2HR HORIZONTAL ASSEMBLY (HA) (SHOWN IN PLAN) GENERAL CODE NOTES 1. SPACES SHOWN WITHOUT SQUARE FOOTAGE IN ROOM TAG (BATHROOMS, CORRIDORS, ETC.) ARE NOT CONSIDERED REGULARLY OCCUPIED PER IBC 202. 2. OCCUPANT LOADS HAVE BEEN CALCULATED PER IBC TABLE 1004.5 EXCEPT WHERE NOTED BASED ON ACTUAL FURNITURE LAYOUT. OVERALL OCCUPANCY HAS BEEN CALCULATED BASED ON HIGHEST LOADS FOR EGRESS REQUIREMENTS AND PLUMBING FIXTURE COUNT. FEC 959 SF 6.39 150 SFP BANKING HALL 101 231 SF 1.54 150 SFP STAFF AREA 112 108 SF 0.72 150 SFP MANAGER 106 107 SF 0.71 150 SFP OFFICE 104 107 SF 0.71 150 SFP OFFICE 103 108 SF 0.72 150 SFP OFFICE 102 110 MEN 111 WOMEN 109 PASSAGE 29 SF 0.20 150 SFP SAFE 108 108 SF 0.72 150 SFP OFFICE 105 113 SF 0.75 150 SFP WORK ROOM 107 154 SF 0.51 300 SFP MECH/ EVS 114 58 SF 0.39 150 SFP RESPITE 113 45 SF 0.15 300 SFP IT/ DATA 115 100 VESTIBULE CP E T = 3 4 ' -8" D 2 = 7 8 '-5 " EX I T EX I T EX I T 13.58 OCCUPANTS, 1 EXIT REQUIRED 2 EXITS PROVIDED EX I T REQUEST TO EXIT BUTTON FOR CONTROLLED ACCESS DOOR EATD = 45'-7" EATD = 29'-0" D1 = 65'-9" 179 SF 1.19 150 SFP STAFF PATIO 116 FUNCTION/USE PROVIDED EXISTING (Y/N) SPRINKLERED (Y/N) AREA ALLOWABLE IBC 2018 NFPA 2012 FIRE AREA -1.1 2,712 SF NO NO B-OCCUPANCY N/A 9,000 SF BANK DOOR # WIDTH/CLEAR OPENING DOOR CAPACITY DOOR RATING EXISTING (Y/N) OCCUPANT LOAD N 100A 72"/68" 340 (0.2") 10 N/A FE UTILITY ENCLOSURE 4' - 0" MIN DOOR # WIDTH/CLEAR OPENING DOOR CAPACITY DOOR RATING EXISTING (Y/N) OCCUPANT LOAD N 100A 72"/68" 340 (0.2") 10 N/A FEC Scale Project number Date Drawn by COPYRIGHT NOTICE: IT IS A VIOLATION FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF A DOCUMENT BEARING THE SEAL OF AN ARCHITECT OR ENGINEER IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. PR O J E C T D E S I G N E D I N CO L L A B O R A T I O N W I T H As indicated G005 CODE COMPLIANCE PLAN 2026-001 (TBD) TRAPPER'S LOOP ROAD, REXBURG, ID 83440 WESTMARK CREDIT UNION 08/12/2026 KAS TOTAL PROVIDED 1 1 1 1 - 1 1 TOTAL REQUIRED 1 1 1 1 - 1 1 ADDITIONAL 1 PER 50 FOR REMAINDER 1 PER 50 FOR REMAINDER 1 PER 80 FOR REMAINDER 1 PER 80 FOR REMAINDER B-OCCUPANCY 7 7 BASELINE 1 PER 25 FOR FIRST 50 1 PER 25 FOR FIRST 50 1 PER 40 FOR FIRST 80 1 PER 40 FOR FIRST 80 NOT REQUIRED 1 PER 1,000 (DUAL HEIGHT ADA ACCESSIBLE) 1 SERVICE SINK MALE FEMALE MALE FEMALE MALE FEMALE OCCUPANCY OCCUPANT LOAD WATER CLOSETS LAVATORIES BATHTUBS/ SHOWERS DRINKING FOUNTAINS OTHER NUMBER OF PLUMBING FIXTURES PER IBC TABLE 2902.1 1/4" = 1'-0"A1 FIRST FLOOR CODE COMPLIANCE PLAN 4. SMOKE BARRIERS N/A 3. HORIZONTAL EXITS N/A 2. CORRIDORS NOT APPLICABLE OPENING PROTECTIVES: 1. STAIR DOORS NOT APPLICABLE CORRIDOR WALLS (IBC 2018 SECTION 1020)NOT APPLICABLE 3. CORRIDORS 0 HR 2. PASSAGEWAYS 1 HR (N/A)EXIT ENCLOSURES 1. STAIRS 1 HR (N/A) SHAFT ENCLOSURES 1 HR (N/A) FIRE WALLS/HORIZONTAL EXITS N/A ROOF CONSTRUCTION 0 HR FLOOR CONSTRUCTION 0 HR 2. NONBEARING 0 HR INTERIOR WALLS:1. BEARING 0 HR 2. NONBEARING 0 HR EXTERIOR WALLS:1. BEARING 0 HR PRIMARY STRUCTURAL FRAME SEE SECTION 201 0 HR FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS ( IBC 2018 TABLE 601) ALLOWABLE PER FLOOR 6,000 SF (MAX) BUILDING AREA (TABLE 506.2) PROVIDED (TOTAL) 2, 750 SF (GROSS) ALLOWABLE 1 STORY ABOVE GRADE PLANE BUILDING STORIES (TABLE 504.4) PROVIDED 1 STORY ABOVE GRADE PLANE ALLOWABLE 40'-0" MAXIMUM BUILDING HEIGHT (TABLE 504.3) PROVIDED APPROXIMATELY 24'-7" BUILDING HEIGHT & AREA REQUIREMENTS NEW CONSTRUCTION CLASSIFICATION OF WORK NOT SPRINKLERED SPRINKLER PROTECTION OCCUPANCY CLASSIFICATION B- BUSINESS CONSTRUCTION CLASSIFICATION TYPE VB IDAHO BUILDING CODE 2018 SUMMARY OF WORK: NEW CONSTRUCTION FOR BANKING FACILITY PROJECT SUMMARY 8/14/2026 (TBD) TRAPPER'S LOOP ROAD, REXBURG, ID 83440 WESTMARK CREDIT UNION Date 08/12/2026 MONUMENT SIGN WESTMARK CREDIT UNION 2,700 SF "RESERVED PARKING" SIGNAGE REMOTE ITM CANOPY "EXIT ONLY" SIGNAGE M A I N E N T R A N C E S T A F F E N T R A N C E ONE-WAY DRIVE THROUGH ON E - W A Y E X I T HIGHWAY 33 TRAPPER'S LOOP ROAD A200 S3 WAYFINDING SIGN 2 WAYFINDING SIGN 1 STAFF PATIO E L E C & M E C H EQUIPMENT ENCLOSURE STEEL RAILING DUMPSTER ENCLOSURE "STAFF PARKING ONLY" SIGNS ADA DOOR BUTTON N A102 A1 A101 A2 SITE LIGHTING, SEE ELECTRICAL DRAWINGS TYP NOTE: ARCHITECTURAL SITE PLAN IS DIAGRAMMATIC IN NATURE AND IS PROVIDED FOR GENERAL REFERENCE ONLY. REFER TO CIVIL, LANDSCAPE AND ELECTRICAL DRAWINGS FOR SITE DIMENSIONS, GRADING, DRAINAGE, UTILITIES, PAVING, LANDSCAPING, LIGHTING FIXTURES AND OTHER SITE-SPECIFIC INFORMATION. A200S2 A200S1 A200 S4 Scale Project number Date Drawn by COPYRIGHT NOTICE: IT IS A VIOLATION FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF A DOCUMENT BEARING THE SEAL OF AN ARCHITECT OR ENGINEER IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. PR O J E C T D E S I G N E D I N CO L L A B O R A T I O N W I T H 1" = 10'-0" G006 ARCHITECTURAL SITE PLAN 2026-001 (TBD) TRAPPER'S LOOP ROAD, REXBURG, ID 83440 WESTMARK CREDIT UNION 08/12/2026 KAS 8/14/2026 (TBD) TRAPPER'S LOOP ROAD, REXBURG, ID 83440 WESTMARK CREDIT UNION Date 08/12/2026