Loading...
HomeMy WebLinkAboutBOLT INSPECTION - 22-00207 - 2970 S Hwy 191 - Robison-Thompson ShopPRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. e0cc857338745243-1747341590441 1 245 N 1st E Rexburg, ID 83440 208.932.4428 File Name: 25085DFR05142025JPC Daily Field Report Date: 05/14/2025 Project Number: 25085 Project Name: Thompson Building Client: Steel Vision Start Time: 01:00 PM Contractor: Steel Vision Time on Project: 2 Current Weather Conditions: Partly Cloudy Wind: Calm Ambient Temperature (°F): 58 Results Inspection Type(s): Structural Steel and Bolting Location(s): Steel Frame Observations/ Remarks: I arrived on site and began my observations of the structural steel and bolting of the steel framing. This building has been up for approximately a year. No previous inspections have been done. I observed that the bolts of the columns to beams and beam to beam connections were tightened to the snug tight position. I observed that the faying surfaces were in contact with each other. No one was on site to notify of my observations. Inspector Information Truck: ODIN Mileage From Lab to Project (One Way) Inspector's Name: Jacob Christensen Inspector's Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. e0cc857338745243-1747341590441 2 Items observed are in general conformance with approved project documents and jurisdictional requirements. Items observed are NOT in general conformance with approved project documents and jurisdictional requirements. (Explanation given in Observations and/or Remarks.) Reviewer's Name: E. Vail Reviewer's Signature: Inspection Images: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. e0cc857338745243-1747341590441 3