Loading...
HomeMy WebLinkAboutSummerfield14Cd1-2026T-) n t-N T T-1 r m VICINITY MAP LJ- PROJECT LIMITS SE 4 SECTION 26 TOWNSHIP 6 NORTH, RANGE 39 EAST OF THE BONE MERIDIAN, CITY OF REXBURG, MADISON COUNTY, IDAHO ISHEET ND SHEET INDEX SHEET NO. SHEET DESCRIPTION 1 INDEX SHEET 2 SUMMERFIELD/2350 WEST ROAD CONSTRUCTION 3 2530 WEST ROAD CONSTRUCTION PG1 4 2530 WEST ROAD CONSTRUCTION PG2 5 DRAINAGE PLAN 6 HYDROLOGY PLAN 7 DRAINAGE DETAILS OWNER/DEVELOPER KARTCHNER LAND MANAGEMENT INC. ATTN: CODY PUZEY 208-529-2116 CIVIL ENGINEER ALLIANCE CONSULTING ENGINEERS, INC. 150 EAST 200 NORTH SUITE P LOGAN, UTAH 84321 435-755-5121 GENERAL NOTES (APPLICABLE TO ALL CIVIL SHEETS): 1. ALL CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, AWWA STANDARDS, CITY OF REXBURG STANDARDS, ISPWC 2020, STATE OF IDAHO AND ANY OTHER APPLICABLE STANDARDS ISSUED BY THE CONTROLLING AGENCY. 2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS BEFORE CONSTRUCTION. ANY DISCREPANCIES BETWEEN CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE OWNER. 3. CONTRACTOR SHALL REPAIR AND/OR REPLACE ANY AREAS AND/OR MATERIALS DAMAGED DURING CONSTRUCTION. 4. CONTRACTOR SHALL MAINTAIN ALL ADJACENT PROPERTY (PUBLIC & PRIVATE) FROM ALL CONSTRUCTION DEBRIS. 5. CONTRACTOR SHALL PROVIDE SMOOTH TRANSITION FROM ALL NEW CONSTRUCTION TO EXISTING CONDITIONS. 6. CONTRACTOR SHALL PROVIDE ALL NECESSARY AUTOMOBILE AND PEDESTRIAN TRAFFIC CONTROL DEVICES REQUIRED BY LOCAL, STATE, AND FEDERAL CODES AND ORDINANCES. 7. CONTRACTOR SHALL REPLACE SURVEY MONUMENTS DAMAGED DURING CONSTRUCTION. SURVEY MONUMENTS TO BE REPLACED BY A REGISTERED, LICENSED LAND SURVEYOR. 8. DIMENSIONS SHOWN ARE TO THE CENTER OF THE PIPELINE UNLESS OTHERWISE NOTED. 9. DISTANCES SHOWN ALONG PIPELINES ARE HORIZONTAL DISTANCES AND NOT ACTUAL PIPE LENGTHS. MORE PIPE MAY BE REQUIRED TO COMPLETE CONSTRUCTION THAN IS DIMENSIONED IN THE PLANS. 10. THRUST BLOCKS SHALL BE PLACED ON WATERLINES AT ALL DIRECTION CHANGES, FITTINGS, BENDS, ELBOWS, FIRE HYDRANTS AND GATES VALVES AS SHOWN IN THE PROJECT PLANS. 11. ALL CONCRETE REQUIRED ON THIS PROJECT SHALL BE 4000 PSF (28 DAY) CONCRETE. 12. CONTRACTOR IS RESPONSIBLE FOR PROVIDING WATER NECESSARY FOR DUST ABATEMENTK, COMPACTION, ETC. 13. THE CONTRACTOR SHALL BE RESONSIBLE FOR SECURING SOURCES FOR GRANULAR MATERIALS, WATER, WASTE SITES, AND ANY OTHER MATERIALS SOURCES AS REQUIRED FOR PROJECT COMPLETION. 14. ANY WORK DONE WITHIN A PUBLIC RIGHT-OF-WAY SHALL BE COORDINATED WITH THE APPROPRIATE TRANSPORTATION AGENCY AND SHALL MEET THE REQUIREMENTS OF THAT AGENCY AND THE REQUIREMENTS OF ANY RIGHT-OF-WAY OR SPECIAL USE PERMITS. 15. THE CONTRACTOR SHALL COORDINATE ALL LIVE TAPS AND ANY OTHER WORK OR MANIPULATION OF THE EXISTING WATER SYSTEM WITH THE ENGINEER AND THE WATER SYSTEM OWNER/CITY. 16. ON SLOPING AREAS THE CONTRACTOR SHALL TAKE PRECAUTIONS TO MITIGATE ANY POSSIBLE EROSION PROBLEMS IN THE TRENCHES DUE TO STORM WATER THAT MIGHT OCCUR DURING OR AFTER CONSTRUCTION AS DIRECTED OR APPROVED BY ENGINEER. 17. THE CONTRACTOR SHALL INSTALL AND MAINTAIN ALL EROSION CONTROL MEASURES AS DETAILED IN THE PROJECT PLANS UNTILL FINAL ACCEPTANCE OF THIS PROJECT. 18. THE CONTRACTOR IS REQUIRED TO TAKE ALL PRECAUTIONS NECESSARY TO INSURE THAT NO STORM WATER/SEDIMENT AND/OR CONSTRUCTION DEBRIS ARE RELEASED FROM THE SITE. ANY RELEASES SHALL BE CLEANED AND MITIGATED AT THE CONTRACTOR'S EXPENSE. 19. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ACCESS AND RELATED TRAFFIC CONTROL WITH THE COUNTY, CITY, AND STATE ROADWAY DEPARTMENTS. THE ENGINEER SHALL REVIEW ALL TRAFFIC CONTROL PLANS. 20. ALL GATE VALVES SHALL BE LOCATED NEAR TO TEES OR CROSSES AND THEIR ASSOCIATED REDUCERS AS SHOWN ON THE PROJECT PLANS. 21. CONTRACTOR SHALL PROVIDE ALL NECESSARY FITTINGS, HARDWARE, LABOR, ETC. TO CONSTRUCT VERTICAL AND HORIZONTAL BENDS IN PIPE AS NEEDED TO MEET THE REQUIRED GRADES, ALIGNMENTS AND COVER REQUIREMENTS. 22. ALL AIR RELEASE VALVES SHALL BE INSTALLED AT THE CREST OF THE VERTICAL CURVATURE OF THE WATER LINE. CONTRACTOR SHALL RECORD ACTUAL LOCATION OF VALVES ON FIELD RECORD DRAWINGS. 23. THE CONTRACTOR SHALL COORDINATE WITH THE CITY OF REXBURG AND WITH THE ENGINEER FOR ALL UTILITY INSPECTIONS PRIOR TO BACKFILLING. 24. THE CONTRACTOR SHALL COORDINATE ALL INSPECTIONS WITH THE ENGINEER. AT A MINIMUM, THE ENGINEER SHALL BE NOTIFIED TO INSPECT: 1)SEWER PRIOR TO BACKFILLING, 2)WATER PRIOR TO BACKFILLING, 3)STORM SEWER PRIOR TO BACKFILLING, 4)CURB & GUTTER AND FORMS PRIOR TO POURING, 5)ROADWAY GRADES PRIOR TO PAVING, 6)ASPHALT DURING PAVING. 25. ALL WATER SYSTEM COMPONENTS SHALL BE INSTALLED, PRESSURE TESTED, AND CHLORINATED PRIOR TO COMPLETING ANY ROADWAY CONSTRUCTION PER AWWA STANDARD 651. 26. CHLORINATION SHALL BE DONE BY CONTRACTOR AT THE CONTRACTORS EXPENSE. CONTRACTOR TO DISPOSE OF CHLORINATED SOLUTION ACCORDING TO AWWA STANDARD C651. 27. ALL SEWER SYSTEM COMPONENTS SHALL BE INSTALLED AND VIDEO INSPECTIONS DONE AND APPROVED PRIOR TO ASPHALTING. IF NECESSARY, THE CONTRACTOR SHALL PAY FOR THIS EXPENSE AS IT IS CONSIDERED INCIDENTAL TO SEWER CONSTRUCTION. 28. SECONDARY WATER LINE MAIN TO BE 6" C-900 DR 14. SERVICES TO BE 1 " CTP POLY FOR SINGLE LOT AND 1-1/2" CTP POLY WITH TEE TO 1" CTP POLY FOR DOUBLE SERVICE. END EACH SERVICE WITH STOP AND WASTE. 29. DEVELOPER TO INSTALL REQUIRED FIBER CONDUITS. FIBER INFRASTRUCTURE WILL FOLLOW THE POWER PLAN. ADDITIONAL TRENCHING AND CONDUITS MAY BE REQURIED. DIG LINE 1-800-342-1585 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKER OF THE UNDERGROUND MEMBER UTILITIES. IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION I.S.P.W.C. 2020 CONSTRUCTION ON THIS PROJECT SHALL CONFORM TO THE I.S.P.W.C. STANDARDS AND CITY OF REXBURG STANDARDS SS\ONA L £Nc, G\SjF,poF�, MACKE\y z O W cr- z o o Q N N N o z o m W J U Q Q � c -pz;4 O pQ o W � �E-4 O E" 0 z z CL (I� w (n N N UW �0 I O �< U') O o _ .� N z Lo ro co O O Q W J O SHEET 1 OF 7 SHFFTS LEGEND SUMMERFIELD SUBDIVISION PROPERTY BOUNDARY E s PVC SEWER EXISTING PVC SANITARY SEWER LINE AS DIVISION 14 NOTED e-s EXISTING SEWER LATERAL SUMMERFIELD12350 NEST ROAD CONSTRUCTION SDR35 SANITARY SEWER s PVC SEWER-�rs} PINOPOSEDE ASOPEDC 4847.9 = 0 PROPOSED 4" PVC SDR 35 SEWER En io' PVI STA = 22+73.50 // ..�0 1 s LATERAL (S=2.0% min) \NAE L SS N� �c� / _ wv 8 WATER B� �' \ S j F� o- ° PVI ELEV = 4849.25 // E DI yo EXISTING WATER LINE -SIZE AS SHOWN 4847.8 / e-w EXISTING WATER LATERAL 4849.15 STA: 22+39.00 / / I PROPOSED DI CLASS 50 WATER LINE AS 10 Begin Road Construction / a 0 30 60 120 8 DI WATER NOTED 1V qTF �P' �6 N SCALE: 1 "= 60' (24X36 PLAN SET) w PROPOSED 1" SERVICE PER ISPWC SD-401 OF q� MA CKE�e�P + 0 4847.8 � "_ SCALE: 1 - 10 VERTICAL - 15 E ADS S EXISTING STORM LINE CB D--fi / 4848.92 O o = fi o 15 ADS SD NEW STORM LINE/CB o,co­jcn o- _ \\�� NOTES: 6 IRR PROPOSED 6" C-900 DR14 IRRIGATION �' 4847.7 0 0.00 a 4848 MAIN W/ VALVES 4848.70 0 All sewer laterals to be installed at 5' below PROPOSED IRRIGATION SERVICE W/ STOP & native ground 10 into property. WASTE (1" SINGLE/1-1/2" TO DOUBLE) z O CIO \ 4 All hydrants t0 be Waterous brand. # EXISTING STREET LIGHT o$887 D # NEW STREET LIGHT -PER CITY STANDARDS � 7 o 00 S W m _ + < Cn - ilk NEW ASPHALT Lr)CN O o morn 4847.? fi5 n 3 j 0 3 S - - - - .... EXISTING ASPHALT LLJ N z J N m PVI STA = 20+33.34 W MH5 �--� } '� I_ N Q Z 4848.25 � V N C % I 4848.`+.` + I O i PROPOSED CONCRETE .+'.y: a'`.i;•a�::.YY. ': :•. rz iv w c0 _ ts..':r PVI ELEV = 4848.17 vC gEWE, 0 a P EXISTING CONCRETE _ + 4847.6 o - j ;,, W Q 4848.32 0 W ��� J 01 o 4847.5 10 0 5, � w 4848.55 N En07. o O S S _ + 0 4847.E 4848.77 PVI STA = 18+62.98 co 4847.4 00° � o I PVI ELEV = 4848.94 w 0 90 6, ry S I� C� 1�.� O 4848.88 C� Ut O W :w C" v IL q I _ + 0 4847.5 _ 00 8 - S �' FL' CO �' O O 4848.66 r W 01 0 0 5 , 68' Q a cn' m zZ S 00 o 4 SIDEWALK C �P4 O L� 4847.4 W ' 30" q w w m D a_ m 5' 7' 19.5' 19.5' ROLLED CURB 4848.43 = F� 2% o 00 O '. :� 2% E-+ i 12" GRANULAR BORROW T^r� O + 4847.4 c� S W //\//\\/� \� \ \\\\/\\/ Lo 00 7 0 q 0 0 4848.21 m � D= I PVI STA = 16+84.59 - 2-1/2" ASPHALT PLANTMIX PAVEMENT 4» ►� �w •• ,-P PVI ELEV = 4848.14 S _ I 1 3-1/2" OF AGGREGATE BASE q 00 o 0 0 w 0 w �, : n USE 12" GRANULAR BORROW 12" � �' 4847.4 L' v, o is - ' - ai �_ �:..... GEOTEXTILE FABRIC BELOW 2.5 wO ~ 4848.28 o N o � � � ILI �: AND UP SIDES �+ S TF �, 484.4 0 (D I 'o \`� S i w ° . �•� 68' TYPICAL ROAD CROSS-SECTION 30 w '� � � W + 0 � 16 ODD O 4848.48 � W D 1 �^ m I \ 4847.2 V. 4848.68 PVI STA = 15+40.16 '�- \ S w PVI ELEV = 4848.72 \, i� oo W Cn 0 4847.1 m OD W 1 - 41:....... I I, 4848.55 0� o 17 O C � w i PVC SEV O 0 w w 8 4847.3 o F a S . y W °° `a o,00 \ S/ CO C N °° r U N Cd Ln 4847.1CL 0 ��� ���m W ;Cl I� ` II II o W U ' N� Q J 4848.15 I y I \\ S t J Q N w o cn w Q J + o w o� � w Z �� rno S\ W ;. > '; sv�=. + > �� a- a- Finish > > _'� � > 3 N c- 0 (Y "� N_ 4847.1 o m PVI STA = 13+50 W J � a grade a- a- Ex FH Q °' a- U) 00 `n / ... A. _..... - U) Original 9 _ O = 4847.95 Io PVI ELEV = 4847.95 __ .. � 4850 ground II Z Q LLO \ ` ° _ _ _ 0. % -0.40% 0 40% - �� L O - - - - - - - - - - - - - - - O oo S E Bop - -- --- ---- 5' min z � 484 I'�H1 E E EWER, ; 0 - Plug, cap 0 4848.37 0 0 \ _ I 0 : �� 10 8 "� block end O J mc°n � 8 PS$ pvC `S,EV�B-�,I � --- .:::,.�:: .•,- '+•=:• ,. 8 Pvc ER 1a DMLpNE �a 4840 Ti to O -E 1 E� -- _��...� < "' New 8" cross 4847.14 PVI STA = 12+50 ER� 1dM MIv1ERF'I _ _ 00 �_. - 8" sewer / O a isting w 4 valves VI ELEV = 4847.97 0 _ = -- . I_ _ _ -4847.0- _ force main MH1-exist 5'dia Drop STA: 8+54.31 7.95 L st b 4847.97 1 oD -+ S _ Rim: 4347.01 raise to 4848.30 _ i' + 4847.1 (A m � W W � I = �� - _ - - - E-in-N-S: 4836.0 IE-in-E: 4831.14 4848.19 = 0 o ` IE-out-W: 4830.99 0 o I DATUM ELEV Ti I CIj 4835.00 01 . t`. u7� con r-n� 00n O� N¢� ron OO�� OO � N� OD, °° °° (6 CO Co �n �'q- °�° 4�� �4847.2 � � ''t N D - �� �� �� �� �� �°° �� �°° � �� �004848.42 EET SH99 PVI STA = 11 +17.46 cn \ A I'1 w 6+00 7+00 8+00 9+00 10+00 1 1 +00 \ S I• SUMMERFIELD LANE U, LEGEND D SUMMERFIELD SUBDIVISION - _ - PROPERTY BOUNDARY .% / EXISTING PVC SANITARY SEWER LINE AS E 8 PVC SEWER 4848 68 PVI STA = 15+40.16 >_ S 00 DIVISION 14 NOTED CA PVI ELEV = 4848.72 \> W r y e-s EXISTING SEWER LATERAL o _ _ - O S ��� 0 WEST ROAD CONSTRUCTION PGA PROPOSED PVC SDR35 SANITARY SEWER i - ',77. 8 PVC SEWER LINE AS NOTED 0� + 0 4847.1 m ao = / W 1 - I 'fft PROPOSED 4" PVC SDR 35 SEWER s �pNAL 4848.55 o LATERAL (S=2.0% min) SS n y td PVC SI I wv E 8 DI WATER yro B� EXISTING WATER LINE -SIZE AS SHOWN �c G \ S L� 4847.3 o \ U > a S 4 " e-w EXISTING WATER LATERAL +' 04>.p \�8-3 �' �- W \\� -- PROPOSED DI CLASS 50 WATER LINE AS 8 DI WATER `� 1 -`� ` 6 4848.35 0 30 60 120 NOTED 9 Oq gTFOF W --- - / - // SCALE: 1 = 60 (24X36 PLAN SET) w PROPOSED 1" SERVICE PER ISPWC SD-401 '�' Q� MA C KEG + 4847.1 Q _0 - - - - - - SCALE: 1 "= 10'_VERTICAL 15 E ADS SD-- EXISTING STORM LINE/CB 4848.15 fi c M 0 - m 1� -] \ S 15 ADS SD NEW STORM LINE/CB FD oo CA o I \ Srn . NOTES: 6 1RR PROPOSED 6" C-900 DR14 IRRIGATION 4847.1 0 co PVI STA = 13+50 J W __; MAIN W/ VALVES 4847.95 to PVI ELEV = 4847.95 -- All sewer laterals t0 be Installed at 5 below PROPOSED IRRIGATION SERVICE W/ STOP & --- native ground 10 into property. WASTE (1" SINGLE/1-1/2" TO DOUBLE)p �... _ SE g�SEW E VC All hydrants to be Waterous brand. # EXISTING STREET LIGHT _ G' 484 " °o �...� P4H1 E E DER, \ o # NEW STREET LIGHT -PER CITY STANDARDS w 0 0 \ -- i o: Ia 9 4848.37 0 _ m 8 E g PVC SSE ! •- : M, . x - .:.. «n.. :.r E ADS NEW ASPHALT (D cn 8 8 Pvc ER- - DMLp`NE ; Ix00 i ... • . 15 C o z P E MMER,FIE� - - - < CI CN 4847.1 PVI STA = 12+50ER _0M _ °D%'� _ EXISTING ASPHALT Q VI ELEV = 4847.97 0 1 - -- = --4847.0- -' ,. r• _ ;r.},f PROPOSED CONCRETE 4847.97 EXISTING CONCRETE � 4847.1 00 z W 4848.19 r m I 0 o = -- oo I J Q :F_ Ln / I coo 9 V / I 4847.2 4848.42 s 4 I PVI STA = 11 +17.46 \ _ C\2 4847.0 PVI ELEV = 4848.56 \ .�, S I { 0 0 -� - W - - - - - - 4848.48 I (Yi P4 --- w -- 4847.1 �o � < � r Co O 4848.26 ° - �' N 0 go 0 4847.1 U' S- W S 0 4848.03 0 o k i W - '" -_ - - - \ ti (� E" 1.0 5 ___ 0D 0 a(n I �zT _ 4847.0 � � close wTesbvalve leave leg q� (� q 4847.81 yest � Suncharged w O PVI STA = 9+03.46 ��� �pl WATER �� ' MH6 W Cr 1 G `� 0 PVI ELEV = 4847.60 o ---- -� - - -4g4 j _ - - - W �w co 4847.61 - - ri "• (0-N -N00+a moo_No -. 4846.9 coc���° W v `�, \S )� (--- �- w w� O 4847.84 v v o c° F� 13 \W --- rncn 0 ao I = ----� _ - - - - i •-tilde E" _U aLLJ Qp _ _ _ --4847.0- > U w R R 4848.06 0 G 68' D o S o� W SIDEWALK 4846.9 I, - 5 7' 19.5' 19.5' 30" LA PVI STA = 7+35.31 MH / 2% _� �_ 2% ROLLED CURB 4848.29 ° !. - w _N w w -,J PVI ELEV = 4848.36 N 12 GRANULAR BORROW 9� S �\ \\���\� / / + 4847.1 rn rn .i r o / W 0 0 w �� 0 �• 4' / Close leave west valve leg 2-1/2" ASPHALT PLANTMIX PAVEMENT 4» 4848.20 N I O west _ -�� _ - _ ��� uncharged Ex gravel 3-1/2" OF �4" AGGREGATE BASE S S turn -around USE 12" GRANULAR BORROW 12" 4847.1 T o _� 0 . I; to be remove � C BELOW GEOTEXTILE FABAND 2.5 4847.97 / , SIDES D C/) I PVI STA = 6+11.46 I� f Fr, \� o� :,... 68' TYPICAL ROAD CROSS-SECTION Co + 4847.1 lCL rw PVI ELEV = 4847.80 D- 30» 4847.86 c j 0 (� >6 _ / .,. W \ - 000 000 ry Do I 0 m x \ ---- 0 (n N c- (Y n N Ill W N a in �l \ \ -_ ` -- DD Lo ci 4847.2 0 -N r- o 0 = c� = -�%`/ 1 . �� .. I 0 \� Cn - STA: 5+ 15.05 - - - --4847.0- - �� �� o N Z � r � a, End Road Construction - - - - - Q Nd- + 0 4847.4 m � '-` I (n o 4848.34 L� o h y 5o � I I o l o t- 4847.5 IN \�---------- a 4848.54 PVI STA = 4+33.75 - - - PVI ELEV = 4848.61 C-------- -------� SHEET 3 OF 7 SHFFTS LEGEND 4850 4840 DATUM ELEV 4835.00 N 17 c n o o m + r- U u u u u U Finish i _j _j Original 04 o grade N w N w ground + $ LOx > a > > U) 4850 cn w Plu91 cap 5' min block end 4840 8" DI waterline DATUM ELEV 4835.00 oo ao o' rn ,C°n o 5+00 6+00 7+00 860 SOUTH STREET � 0 m00 N .0) a)� .r- �� �O r) (O (D ,6 (0 r (D t � Cfl r 00 00 00 tb 00 OR 8+00 9+00 10+00 960 SOUTH STREET W_ 90 if[1100] 0 0 30 60 120 SCALE: 1 "= 60' (24X36 PLAN SET) SCALE: 1 "= 10'_VERTICAL NOTES: All sewer laterals to be installed at 5' below native ground 10' into property. All hydrants to be Waterous brand. - 5' 7' 2% —� i.X/ X�\ 19.5' -.-*— 2% 19.5' PROPERTY BOUNDARY E s PVC SEWER EXISTING PVC SANITARY SEWER LINE AS NOTED e-s EXISTING SEWER LATERAL PROPOSED PVC SDR35 SANITARY SEWER s PVC SEWER— 9 LINE AS NOTED PROPOSED 4" PVC SDR 35 SEWER S LATERAL (S=2.0% min) Wv E 8 DI WATER *Y�o EXISTING WATER LINE -SIZE AS SHOWN e-w EXISTING WATER LATERAL PROPOSED DI CLASS 50 WATER LINE AS 8 DI WATER NOTED w PROPOSED 1" SERVICE PER ISPWC SD-401 15 E ADS SD-- EXISTING STORM LINE/CB 15 ADS SD NEW STORM LINE/CB PROPOSED 6" C-900 DR14 IRRIGATION 6 IRR MAIN W/ VALVES PROPOSED IRRIGATION SERVICE W/ STOP & WASTE (1" SINGLE/1-1/2" TO DOUBLE) # EXISTING STREET LIGHT # NEW STREET LIGHT -PER CITY STANDARDS 2-1/2" ASPHALT PLANTMIX PAVEMENT 3-1 /2" OF i4" AGGREGATE BASE USE 12" GRANULAR BORROW — GEOTEXTILE FABRIC BELOW AND UP SIDES 68' TYPICAL ROAD CROSS-SECTION NEW ASPHALT EXISTING ASPHALT PROPOSED CONCRETE EXISTING CONCRETE u� _ 30" ROLLED CURB 4" 12" 2.5" 30" SIDEWALK 12" GRANULAR BORROW ��ONAL E c �Te Oq qTE OF SOP P� \MA CKE�ej z O W CC o z o LLJ Q N I N � N J Q z m LU Q J U Q � O W pq C\� �E rw o O o co W � �w O D_ D_ CL w V)C� n N L0 ry O �LLi 0 o o .� N z uo ro J O SHEET 4 OF 7 SHEETS SUMMERFIELD SUBDIVISION DIVISION NO.14 LEGEND Drainage Area to Pond: Weighted 'C' value for Pond Drainage Area Allowable Infiltration Rate: Soil Group A/B Pond Bottom Area: 25-Year Return Period AREA A 2.05 acres 0.44 6.0 inches/hr = 0.0083 ft/min 20 ft x 50 ft = 1000 sq. ft. Precip.* Precip. Accum. Allowable Accum. Required Interval Intensity Depth Area C CxAx3630 Inflow Discharge Discharge Storage (min) (in/hr) (in) (ac) Value (ft"3/in) (ft3/min) (ft"3/min) (ft'3) (ft'3) (ac-ft) 5 3.66 0.31 2.05 0.44 3274.26 998.6493 8 42 957 0.02 10 2.95 0.49 2.05 0.44 3274.26 1609.8445 8 83 1527 0.04 15 2.30 0.58 2.05 0.44 3274.26 1882.6995 8 125.00 1758 0.04 30 1.55 0.77 2.05 0.44 3274.26 2534.2772 8 250.00 2284 0.05 60 0.91 0.91 2.05 0.44 3274.26 2979.5766 8 500.00 2480 0.06 0.15 pervious Drainage Area to Pond: Weighted 'C' value for Pond Drainage Area: Allowable Infiltration Rate: Soil Group A/B Pond Bottom Area: 25-Year Return Period AREA D 59765 sf 0.95 impervious 34760 2.17 acres 10 ftx 0.44 6.0 inches/hr = 0.0083 ft/min 55 ft = Drainage Area to Pond: Weighted 'C' value for Pond Drainage Area: Allowable Infiltration Rate: Soil Group A/B Pond Bottom Area: 25-Year Return Period GRADING/DRAINAGE PLAN <t; 0 30 60 120 SCALE: 1 "= 60' (24X36 PLAN SET) AREA B 2.26 acres 0.41 6.0 inches/hr = 0.0083 ft/min 10 ftx 55 ft = 550 sq. ft. Precip.* Precip. Accum. Allowable Accum. Required Interval Intensity Depth Area C CxAx3630 Inflow Discharge Discharge Storage (min) (in/hr) (in) (ac) Value (ft"3/in) (ft3/min) (ft'3/min) (ft"3) (ft^3) (ac-ft) 5 3.66 0.31 2.26 0.41 3363.558 1025.8852 5 23 1003 0.02 10 2.95 0.49 2.26 0.41 3363.558 1653.7494 5 46 1608 0.04 15 2.30 0.58 2.26 0.41 3363.558 1934.0459 5 68.75 1865 0.04 30 1.55 0.77 2.26 0.41 3363.558 2603.3939 5 137.50 2466 0.06 60 0.91 0.91 2.26 0.41 3363.558 3060.8378 5 275.00 2786 0.06 sf AREA E 0.15 pervious 45530 sf 0.95 impervious 29393 sf Drainage Area to Pond: 1.72 acres Weighted 'C' value for Pond Drainage Area: 0.46 Allowable Infiltration Rate: 6.0 inches/hr = 0.0083 ft/min Soil Group A/B 550 sq. ft. Pond Bottom Area: 10 ftx 55 ft = 550 sq. ft. Precip.* Precip. Accum. Allowable Accum. Required Interval Intensity Depth Area C CxAx3630 Inflow Discharge Discharge Storage (min) (in/hr) (in) (ac) Value (ft"3/in) (ft3/min) (ft"3/min) (ft"3) (ft"3) (ac-ft) 5 3.66 0.31 2.17 0.44 3498.8958 1067.1632 5 23 1044 0.02 10 2.95 0.49 2.17 0.4441867 3498.8958 1720.2905 5 46 1674 0.04 15 2.30 0.58 2.17 0.4441867 3498.8958 2011.8651 5 68.75 1943 0.04 30 1.55 0.77 2.17 0.4441867 3498.8958 2708.1454 5 137.50 2571 0.06 60 0.91 0.91 2.17 0.4441867 3498.8958 3183.9952 5 275.00 2909 0.07 25-Year Return Period Precip.* Precip. Accum. Allowable Accum. Required Interval Intensity Depth Area C CxAx3630 Inflow Discharge Discharge Storage (min) (in/hr) (in) (ac) Value (ft^3/in) (ft3/min) (ft"3/min) (ft'3) (ft'3) (ac-ft) 5 3.66 0.31 1.72 0.46 2896.0708 883.3016 5 23 860 0.02 10 2.95 0.49 1.72 0.4638476 2896.0708 1423.9015 5 46 1378 0.03 15 2.30 0.58 1.72 0.4638476 2896.0708 1665.2407 5 68.75 1596 0.04 30 1.55 0.77 1.72 0.4638476 2896.0708 2241.5588 5 137.50 2104 0.05 60 0.91 0.91 1.72 0.4638476 2896.0708 2635.4245 5 275.00 2360 0.05 I 0.15 pervious Drainage Area to Pond: Weighted 'C' value for Pond Drainage Area Allowable Infiltration Rate: Soil Group A/B Pond Bottom Area: AREA C 87239 sf 0.95 impervious 51717 3.19 acres 10 ftx 0.45 6.0 inches/hr = 0.0083 ftimin 55 ft = sf 550 sq. ft. 15 E ADS SD 15 ADS SD PROPERTY BOUNDARY EXISTING STORM LINE/CB NEW STORM LINE/CB NEW MJR CONTOUR (2.5') NEW MNR CONTOUR (0.5') ORIGINAL MJR CONTOUR (5') ORIGINAL MNR CONTOUR (1') Neenah R-3067 or equivalent grates required on all catch basins. 25-Year Return Period Precip.* Precip. Accum. Allowable Accum. Required Interval Intensity Depth Area C CxAx3630 Inflow Discharge Discharge Storage (min) (in/hr) (in) (ac) Value (ft^3/in) (ft3/min) (ft"3/min) (ft^3) (ft"3) (ac-ft) 5 3.66 0.31 3.19 0.45 5184.75 1581.3488 5 23 1558 0.04 10 2.95 0.49 3.19 0.447746 5184.75 2549.1688 5 46 2503 0.06 15 2.30 0.58 3.19 0.447746 5184.75 2981.2313 5 68.75 2912 0.07 30 1.55 0.77 3.19 0.447746 5184.75 4012.9965 5 137.50 3875 0.09 60 0.91 0.91 3.19 0.447746 5184.75 4718.1225 5 275.00 4443 0.10 /TONAL E c 71,f,4�711 OF�MA CKE�ej z 0 W CC LO o z o Q NLLJ I N � N J Q z co W Q J U Q � a� ^ w EE-+ O O �E-" w O q �o -D 0 ry n SHEET 5 OF 7 SHEETS SUMMERFIELD SUBDIVISION DIVISION NO.14 LEGEND GRADING/DRAINAGE PLAN <t; 0 30 60 120 SCALE: 1 "= 60' (24X36 PLAN SET) tlo( H: 'K34U. U/ Volume: 3,103 cf 15 E ADS SD 15 ADS SD PROPERTY BOUNDARY EXISTING STORM LINE/CB NEW STORM LINE/CB NEW MJR CONTOUR (2.5') NEW MNR CONTOUR (0.5') ORIGINAL MJR CONTOUR (5') ORIGINAL MNR CONTOUR (1') Neenah R-3067 or equivalent grates required on all catch basins. /TONAL E c ��, S T 90 qTE 2 OFQ`c q� MA CKE�ej z 0 w CC LO o z o Q NLLJ I N � N J Q z 0o w Q J U Q � o w� w E" E-"_ 0 O �� �o - E" 0 ry n CL w V)C00 � N ry I O �LLi 0 o o .� N z Ln ro J 0 6 SHEET OF 7 SHEETS TOP VIEW R T SECTION A A ISOMETRIC GRATE TYPE II N.T.S. 3 WELD (4) 1/2" x 3" 30" STUDS 0 h SEE NOTES BELOW 0 0 1-3/4" x 1-3/4" x 1 /4" STEEL ANGLE TOP VIEW END VIEW GRATE FRAME DETAIL NOTES N.T.S. LEGEND O FOUR-SIDED FRAME IS REQUIRED. O1 1-1/2" x 3/4" STEEL BARS (TYP.). 1000NTRACTOR HAS THE OPTION OF WELDING THE BACK STEEL ANGLE BAR INTO PLACE AFTER SLIP FORMS FOR 20 1/4" FILLET WELD ALL BARS. BOX HAVE BEEN REMOVED. ENSURE GRATE FRAME IS 4 PLACES (TYP.) SQUARE BEFORE DOING A FULL PENETRATION WELD TO ATTACH BACK STEEL ANGLE BAR. 30 WELD (4) 1/2"x3" STUDS. 2005 IDAHO STANDARDS FOR PUBLIC WORKS CONSTRUCTION CATCH BASIN GRATE TYPE 11 STANDARD DRAWING NO. JU J O O° .r..: CD O Q Q . Q 0 0 0 Q CD Q Cj QQ °QQ°Q 0 Q QQQ ° Q_D Q Q .', PERFORARTED O ° ° PRECAST CONCRETE BARRELS Q O Q 0 Q CD Q Q Q Q QQ 4' ° 0 0 ° O Q Q Q 0 00 Q O O ° O Q Q Q Q 6' 6'-6" RAID. SUMP DETAIL NOT TO SCALE STANDARD SIZE "A" GRATE FOR 30" CATCH BASIN 11_%� , FRAME FOR 30 CATCH BASIN ,,—EXTEND POURED IN PLACE CURB & GUTTER AROUND FRAME & GRATE CATCH BASIN HEAD 30" CATCH BASIN BARREL ASTM C-478 111- •u I i IS IM11 I STIVE 4" OF T' 1' topsoil .� 0O0 0 00 000 00 0 0 O o00 0 0 o00 0 0 0 00 0 0 0 0 0 0 0 0 0 00 0 C-)0 000 SUMMERFIELD SUBDIVISION DIVISION NO.14 DRAINAGE DETAILS DRAINAGE DETAILS 20" DUI. TYPICAL PLAN VIEW NOTE: 1. THE USE OF THIN WALL KNOCKOUTS IN CATCH BASIN BARRELS IS NOT MANDATORY. FACTORY OR FIELD CORED HOLES IN A STD. 2'-6" DIA. REINFORCED CONCRETE PIPE DESIGNED FOR VERTICAL INSTALLATION & ALSO TO WITHSTAND HS-20 LOADING WILL ALSO BE APPROVED. 37" �30"� A SECTION A SIDE VIEW SD-5 30" CATCH BASIN PIPE ) 00 CD CD CD CD00 00 00 0 0 0 0 0 00 0 0 CD 0 0 CD 0 00CD ,. 0 Oo Oo Oo 0 0 0 CDC) COURSE ROCK CD 0 BACKFILL 2" 0 0 0 o MIN.-6" MAX 0 CD CD C) 0 CD 0 0 0 Oo o o 0 4' MIN. 6'-6" RAID. NOT TO SCALE WALL KNOCKOUTS NOTE POURED CONCRETE BASE N 30" DIA. CATCH BASIN A. � I B I e • SD-5 2'-0„ 3'-3" 1 30" DL4. CATCH BASIN SD-5 TYPE 1 THIS C.B. IS A MODIFIED ITD TYPE 1 C.B. PER ITD STD. DWG. E-6-A. APPROXIMATE WEIGHTS M,H. LID 540 LBS. 4' M.H. SECTION 1,470 LBS. (INCLUDES 4" BASE) REINFORCING NOTES: 1. REINF. TO BE CENTERED IN CONCRETE UNLESS OTHERWISE NOTED. 2. ALL LAPS TO BE A MINIMUM OF 48 BAR DIAMETERS. 3. CLEAR SPACING BETWEEN ANY PAR&L EL REINF. TO BE A MINIMUM OF 1 1 2 . 4. MANHOLE SECTIONS ARE DESIGNED TO MEET ASTM C478 LID DESIGN CRITERIA: CONCRETE STRENGTH (28-DAY)-5,000 PSI STEEL YIELD STRENGTH 60 000 PSI SOIL DENSITY 120 �CF EQUIV. SOIL FLUID PRESSURE 0 �45 PCF DEPTH OF FILL AASHTO LOADING HS20 W2 4 REBAR FLOW LINE OF CURB A C ORS - LOCATE 3 1/2" FROM EDGE TOP OF CURB OF OPENING (TYP.) 2'-0, .:. BOTTOM OF CURB t B SECTION B SD-5 SHOWN WITHOUT FRAME & GRATE D SECTION D SD-5 SUMP CONDITION SHOWN WITH FRAME & GRATE INLET CURB & GUTTER FRAME & GRATE CONCRETE APRON (2) #4 REBAR ANCHORS -LOCATE OFI12- FROM EDGEOPENING (TYP.) LOW LINE OF CURB .• TOP OF CURB ' 1 " 4 „ ic-"\ SECTION C SD-5 30" DIA. CATCH BASIN HEAD CURB & GUTTER STYLE BOTTOM OF CURB J D SECTION D SD-5 GRADE CONDITION SHOWN WITH FRAME & GRATE 30" CATCH BASIN CURB N STALATI ON NOT TO SCALE STANDARD MH RING & COVER FLUSH WITH GROUND SURFACE STANDARD MH CONE SECTION 12"-24" 15" INLET FROM CATCH INTOO INNBASIN. INFILTRATOR ERSEPARATOR RING � STD 4'dia MANHOLE 12" PVC TO SUMP SECURE PIPE TO FLE OPENING FLEXIBLE SEAL,, TYP. WALL W/ SS STRAP 2' AND HARDWARE. 2, T 1 1' 4" minus i �� • i LOWER 1' PRECAST SOLID FLOOR AND LOWER MH SECTION CROSS SECTION Invert per plan nn�,r..rniT /nnninr�rTE ADS 601 GEOTEXTI LE OR EQUAL MC-3500 CHAMBER 31, Bottom of Chambers (BoCH) J STORMTECH DETAIL SEE MANUFACTURER FOR INSTALLATION DETAILS NA L EN�i OFF Q �G\STEM, - 6 9�q qTE OF MAC K z O W z LO C) Q NLLJ I N N J Q � z o o m Lu J U Q Q � O W pq WO U) �O q �W O� �o _ O / ^ V / CL LLJ z T I- �- (n N N c00� o I U)� L0 o�� O Z Lo L0 C)Q W J O SHEET 7 M OF 7 SHFFTS