Loading...
HomeMy WebLinkAboutMadison Square Building Plans (1) (1)STRUCTURALCIVIL MECHANICAL PLUMBING ELECTRICALARCHITECTURAL A NEW PROJECT: REXBURG, IDAHO ARCHITECT HARRIS ARCHITECTURE OREM, UTAH 801.377.6303 STRUCTURAL ENGINEER ACUTE ENGINEERING OREM, UTAH 801.229.9020 ELECTRICAL ENGINEER PAYNE ENGINEERING INC. POCATELLO, IDAHO 208.232.4439 CIVIL ENGINEER EAGLE ROCK ENGINEERING REXBURG, IDAHO 208.359.2665 COVER - VACINITY MAP/ NOTES/ INDEX/ ABBREVIATIONS/ CONTACTS C-1 - EXISTING CONDITIONS/ DEMOLITION PLAN C-2 - OVERALL UTILITY SITE PLAN/ GRADING PLAN C-3 - STORM PLAN SN1 - GENERAL STRUCTURAL NOTES S0.0 - FOOTING & FOUNDATION PLAN S0.1 - BASEMENT SHEAR WALL PLAN S1.0 - MAIN FLOOR FRAMING PLAN S1.1 - MAIN FLOOR SHEAR WALL PLAN S2.0 - SECOND FLOOR FRAMING PLAN S2.1 - SECOND FLOOR SHEAR WALL PLAN S3.0 - THIRD FLOOR/ LOWER ROOF FRAMING PLAN S3.1 - THIRD FLOOR SHEAR WALL PLAN S4.0 - UPPER ROOF FRAMING PLAN SD1 - STRUCTURAL DETAILS SD2 - STRUCTURAL DETAILS M1.0 - BASEMENT MECHANICAL PLAN M1.1 - 1ST & 2ND LEVEL MECHANICAL PLANS M1.2 - 3RD LEVEL MECHANICAL PLAN M1.3 - LARGE SCALE MECHANICAL PLANS M1.4 - LARGE SCALE MECHANICAL PLANS P1.0 - FOUNDATION PLUMBING PLAN P1.1 - 1ST & 2ND LEVEL PLUMBING PLANS P1.2 - 3RD LEVEL PLUMBING PLANS P1.3 - LARGE SCALE PLUMBING PLANS P1.4 - LARGE SCALE PLUMBING PLANS P2.0 - PLUMBING DETAILS & SCHEDULES E1.0 - ELECTRICAL NOTES, DETAILS & SCHEDULES E1.1 - ELECTRICAL NOTES, DETAILS & SCHEDULES E1.2 - HOUSE ELECTRICAL PLANS E1.3 - HOUSE ELECTRICAL PLANS E2.0 - TOWN HOME #1 ELECTRICAL PLANS E2.1 - TOWN HOME #2 ELECTRICAL PLANS E2.2 - TYPICAL APARTMENT ELECTRICAL PLANS E3.0 - TYPICAL APARTMENT ELECTRICAL PLANS A0.0 - COVER / SHEET INDEX A0.1 - PROJECT INFORMATION A1.0 - BASEMENT LEVEL FLOOR PLAN A1.1 - LEVEL 1 FLOOR PLAN A1.2 - LEVEL 2 FLOOR PLAN A1.3 - LEVEL 3 FLOOR PLAN A1.4 - ROOF PLAN A2.0 - FRONT EXTERIOR ELEVATION A2.1 - REAR EXTERIOR ELEVATION A2.2 - LEFT & RIGHT SIDE EXTERIOR ELEVATIONS A3.0 - CUT SECTIONS & DETAILS A3.1 - CUT SECTIONS & DETAILS A3.4 - WALL TYPE DETAILS A4.0 - WINDOW / DOOR TYPES A4.1 - DOOR SCHEDULE A4.2 - DOOR / WINDOW DETAILS A4.3 - TYPICAL PENETRATIONS DETAILS A4.4 - TYPICAL PENETRATIONS DETAILS A4.5 - TYPICAL PENETRATIONS DETAILS A4.6 - TYPICAL PENETRATIONS DETAILS A4.7 - TYPICAL PENETRATIONS DETAILS A5.1 - MISCELLANEOUS FINISH DETAILS MECH. & PLUMBING ENGINEER ENGINEERED SYSTEMS ASSOCIATES POCATELLO, IDAHO 208.233.0501 MADISON SQUARE APARTMENTS PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 0 - 0 - C O V E R . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 TI T L E S H E E T / S H E E T I N D E X - PP-1 -STORM PLAN D-1 -DETAILS SHEET MADISON SQUARE Rexburg, Idaho PROJECT NO. 20123 CIVIL SITEWORK FOR: BEING PART OF LOTS 3 AND 4, BLOCK 29 OF THE ORIGINAL REXBURG TOWNSITE, LOCATED IN SECTION 19, TOWNSHIP 6 NORTH, RANGE 40 EAST OF THE BOISE MERIDIAN, MADISON COUNTY, IDAHO VICINITY MAP 1.UNLESS OTHERWISE SHOWN ON THESE PLANS ALL WORK IS TO BE IN ACCORDANCE WITH THE CURRENT CITY OF REXBURG STANDARD DRAWINGS AND SPECIFICATIONS - (ISPWC STANDARDS IF APPLICABLE) . THE CONTRACTOR IS REQUIRED TO HAVE A CURRENT COPY OF SAID STANDARDS ON SITE AT ALL TIMES. 2.ALL DISTANCES AND DATA SHALL BE CHECKED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. IN THE EVENT OF CONFLICT THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY SO CLARIFICATION MAY BE MADE PRIOR TO THE START OF CONSTRUCTION. 3.ELEVATIONS SHOWN ARE 2004 CITY DATUM AND ALL ELEVATIONS AND ARE TO FINISHED SURFACE OR PIPE INVERT UNLESS OTHERWISE NOTED. 4.THE CONTRACTOR SHALL PROVIDE REQUIRED TRAFFIC CONTROL IN ACCORDANCE WITH THE LATEST EDITION OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). 5.GENERAL LOCATIONS AND SIZES OF UTILITIES ARE SHOWN ON THE PLANS. THEY ARE TO BE USED FOR GENERAL INFORMATION ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE APPROPRIATE UTILITY COMPANIES WHEN CONSTRUCTION MIGHT INTERFERE WITH NORMAL OPERATION OF ANY UTILITIES. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO HAVE THE APPROPRIATE UTILITY COMPANY FIELD LOCATE ANY UTILITY INSTALLATIONS WHICH MIGHT BE AFFECTED BY CONSTRUCTION PRIOR TO BEGINNING WORK IN THAT AREA. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING SERVICE OF EXISTING UTILITIES AND FOR RESTORING ANY UTILITIES DAMAGED DUE TO CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER. 6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING SOURCES FOR GRANULAR MATERIAL, DISPOSAL SITES, AND ANY ADDITIONAL MATERIALS THAT MAY BE NECESSARY FOR PROPER CONSTRUCTION OF THIS PROJECT. 7.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE ARRANGEMENTS FOR WATER REQUIRED FOR TESTING, COMPACTION AND DUST CONTROL MEASURES. 8.A CITY OF REXBURG PUBLIC WORKS LICENSE IS REQUIRED FOR ANY/ALL CONTRACTORS WORKING WITHIN THE PUBLIC RIGHT-OF-WAY OR EASEMENT. 9.APPROVAL OF THE CITY ENGINEER IS REQUIRED FOR ANY PROPOSED CONSTRUCTION WITHIN A PUBLIC RIGHT-OF-WAY OR EASEMENT. 10.ALL CONSTRUCTION INCLUDING CONCRETE/ASPHALT PLACED WITHIN THE RIGHT-OF-WAY REQUIRES INSPECTION AND APPROVAL OF THE CITY ENGINEERING DEPARTMENT. THE DEPARTMENT SHALL BE NOTIFIED AT LEAST FOUR (4) HOURS PRIOR TO PLACEMENT (359-3020). 11.A PUBLIC RIGHT-OF-WAY USE PERMIT IS REQUIRED FOR ANY WORK WITHIN ANY PUBLIC RIGHT-OF-WAY OR EASEMENT. THE CITY OF REXBURG ENGINEERING DEPARTMENT SHALL BE NOTIFIED AT LEAST TWO (2) DAYS PRIOR TO ANY EXCAVATION UNDER THIS PERMIT (359-3020). 12.THE CONTRACTOR SHALL RETAIN AND PROTECT OR REMOVE AND REPLACE ALL LANDSCAPING, TREES, UTILITIES, DITCHES, CULVERTS, FENCES, MAILBOXES, SIGNS, LIGHT POLES, HEAD GATES, AND ALL OTHER MISCELLANEOUS ITEMS AS CALLED FOR IN THE PLANS. ANY DAMAGE DONE BY THE CONTRACTOR TO EXISTING STRUCTURES TO REMAIN SHALL BE REPAIRED OR REPLACED AT CONTRACTOR'S EXPENSE. 13.CONTRACTOR TO BE RESPONSIBLE FOR FILING THE OFFICIAL SWPP PLAN AND NOI IN ACCORDANCE WITH EPA STANDARDS AND MAINTAINING THESE STANDARDS INCLUDING STORM WATER POLLUTION AND DUST CONTROL PER THE STATE OF IDAHO CATALOG FOR BEST MANAGEMENT PRACTICES (BMP'S). 14.SITE ADDRESS: ,REXBURG, IDAHO (CITY OF REXBURG TO PROVIDE). APPROVED BY: CITY OF REXBURG ENGINEERING DEPARTMENT APPROVED BY: ROCKY MOUNTAIN POWER APPROVED BY: CITY OF REXBURG FIRE DEPARTMENT APPROVED BY: CENTURY LINK APPROVED BY: INTERMOUNTAIN GAS 1.ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE CURRENT CITY OF REXBURG STANDARD SPECIFICATIONS AND DRAWINGS. 2.ALL WATER MAIN PIPING WITHIN CITY RIGHT-OF-WAY SHALL BE DUCTILE IRON CLASS 50 MEETING CITY OF REXBURG STANDARDS. 3.ALL WATER MAIN PIPING WITHIN THE PROJECT SITE SHALL BE PVC C900 DR 18 MEETING ANSI/AWWA STANDARDS (OR EQUAL UPON APPROVAL OF ENGINEER). 4.SERVICE LINE PIPING SHALL BE ONE INCH AWWA C-901 CLASS 200 SDR 7 IPS PE. CONSTRUCT WATER SERVICE CONNECTIONS PER APPLICABLE ISPWC STANDARD DETAIL SD-401 AND SD-402 INCLUDING METER BOX, PIPING AND ALL FITTINGS. 5.WATER MAIN VALVES SHALL BE RESILIENT WEDGE GATE VALVES FOR 10” AND SMALLER PIPES AND BUTTERFLY VALVES FOR LARGER DIAMETER PIPES RATED AT 250 PSI OR GREATER. 6.MINIMUM COVER OVER ALL WATER LINES SHALL BE 6 FEET. 7.THRUST BLOCKS SHALL BE PLACED AT ALL DIRECTION CHANGES INCLUDING BUT NOT LIMITED TO ALL TEES, CROSSES, BENDS, AND END OF LINES. CONTRACTOR SHALL PROVIDE TEMPORARY CAPS AND THRUST BLOCKS AT ALL TEMPORARY WATERLINE TERMINATION POINTS AS REQUIRED DUE TO PHASED DEVELOPMENT. 8.FIRE HYDRANTS SHALL BE WATEROUS WB 67-250, PAINTED RED, INSTALLED WITH A 5” STORZ FITTING AND CAP. HYDRANTS SHALL HAVE TWO 2-1/2 INCH DIAMETER HOSE NOZZLES AND ONE 4-1//2 INCH DIAMETER HOSE NOZZLE. 9.COORDINATE ALL WATER METER INSTALLATIONS WITH THE CITY OF REXBURG. WATER METERS SHALL BE INSTALLED IN ACCORDANCE WITH THE CITY OF REXBURG (BY OTHERS). 10.COORDINATE LOCATION OF WATER METERS FOR LANDSCAPING/SPRINKLER SYSTEMS WITH OWNER'S IRRIGATION PLAN. 11.HOT TAP CONNECTIONS SHALL BE PER CITY OF REXBURG STANDARDS. 12.BED PIPE IN NATIVE MATERIAL FREE OF ROCKS LARGER THAN 1 INCH IN DIAMETER AS BEDDING. IF ROCKS LARGER THAN 1 INCH ARE PRESENT, USE CRUSHED AGGREGATE OR SAND AS APPROVED BY THE ENGINEER. 13.EXTEND WATERLINES 5 FEET OUTSIDE OF PHASING LIMITS. PLACE TEMPORARY BLIND FLANGE AND THRUST RESTRAINT AT TEMPORARY END. IF MECHANICAL THRUST RESTRAINTS ARE USED (SUCH AS EBAA IRON MEGALUGS) RESTRAIN 3 PIPE BELL JOINTS FROM THE TEMPORARY END. MARK ALL END LOCATIONS WITH A POST. 14.WATER PIPE SHALL HAVE A MINIMUM HORIZONTAL SEPARATION DISTANCE OF 10 FEET AND VERTICAL DISTANCE OF 18 INCHES FROM ALL SANITARY/STORM SEWERS MEASURED FROM THE EDGE OF EACH PIPE IN ACCORDANCE WITH IDAPA 58.01.08 AND AS OUTLINED IN THE CURRENT EDITION OF THE ISPWC STANDARD DRAWING SD-407. 15.COMPLY STRICTLY TO MANUFACTURER INSTALLATION REQUIREMENTS IN ALL CONSTRUCTION AND IN REGARDS WITH PULLED JOINTS AND DEFLECTION TOLERANCES. USE STANDARD ELBOWS, WHEREVER POSSIBLE, IN LIEU OF PULLING JOINTS EVEN IF THE JOINT PULLS ARE WITHIN MANUFACTURER INSTALLATION TOLERANCES. 16.ALL WATER PIPE SHALL INCLUDE ALL APPURTENANCES INCLUDING BUT NOT LIMITED TO TEES, CROSSES, VALVES, ELBOWS, ETC.… 17.TEST, FLUSH, AND DISINFECT CONSTRUCTED PIPE IN ACCORDANCE WITH THE CURRENT EDITION OF ISPWC SECTIONS 401.3.6 AND 401.3.9. 1.ALL CONSTRUCTION SHALL BE PER THE CURRENT CITY OF REXBURG STANDARD DRAWINGS AND SPECIFICATIONS AND/OR CURRENT EDITION OF THE ISPWC IF APPLICABLE. 2.ALL SANITARY SEWER MAIN LINE PIPING SHALL BE PVC SDR 35 IN ACCORDANCE WITH ASTM D-3034. 3.ALL STORM SEWER MAIN LINE PIPING SHALL BE ADS N-12 WT IB PIPE MEETING AASHTO M252, AASHTO M294 TYPE S AND ASTM F2306 WITH SMOOTH INTERIOR AND ANNULAR EXTERIOR CORRUGATIONS (OR EQUAL UPON APPROVAL OF ENGINEER). 4.ALL SEWER SERVICE LINES SHALL BE 4 INCH PVC SDR 35 AND SHALL EXTEND 15 FEET INTO THE PROPERTY (EASEMENT LINE) AND MARKED WITH A 2X4 POST. SERVICE LINE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE APPLICABLE ISPWC STANDARD DRAWING SD-511, SD-511A, SD-511B AND SD-512. 5.MANHOLES SHALL BE IN ACCORDANCE WITH CITY OF REXBURG STANDARDS AND ISPWC STANDARD DRAWING SD-501. 6.PIPE BEDDING SHALL BE IN ACCORDANCE WITH ISPWC STANDARD DRAWING SD-301 AND SD-302. 7.GRADE, SLOPE, AND FINISH SURFACES AWAY FROM MANHOLE LIDS. 8.DO NOT ALLOW MORE THAN 12 INCHES OF GRADE RINGS ON MANHOLES BEING RAISED TO FINAL GRADE. 9.TEST GRAVITY SEWER PIPE IN ACCORDANCE WITH ISPWC SECTION 501.3.4. WATER NOTES: SEWER NOTES: 1.LANDSCAPING REQUIRED OVER 10% OF TOTAL AREA AND 10% OF TOTAL SNOW STORAGE PLOWED AREA. LANDSCAPE/GREEN SPACE/ SNOW STORAGE CITY OF REXBURG ENGINEERING DEPARTMENT KEITH DAVIDSON (208) 359-3020 DEQ GREG EAGER, PE (208) 528-2650 DIGLINE (CALL BEFORE YOU DIG)811 OR (800) 342-1585 EAGLE ROCK ENGINEERING PROJECT ENGINEER PAUL SNARR (208) 542-2665 PROJECT MANAGER PAUL SNARR (208) 542-2665 COVER VICINITY MAP/LOCATION MAP/NOTES/INDEX/ABBREVIATIONS/CONTACTS C-1 EXISTING SITE CONDITIONS/DEMOLITION PLAN C-2 SITE PLAN/UTILITY C-3 STORM WATER RETENTION PLAN/GRADING PLAN PP-1 PLAN & PROFILE D-1 DETAILS EL ELEVATION FF FINISHED FLOOR INV INVERT O.C.ON CENTER REQ'D REQUIRED STD STANDARD TEMP TEMPORARY TYP TYPICAL TBC TOP BACK OF CURB DWG DRAWING FL FLOW LINE OF CURB X-TBC EXISTING TOP BACK OF CURB X EXISTING BTM BOTTOM FO FINISHED OIL GRADE EO EDGE OF OIL MH MANHOLE SSMH SANITARY SEWER MANHOLE CB CATCH BASIN FW FRONT OF SIDEWALK BW BACK OF SIDEWALK GB GRADE BREAK TOW TOP OF WALL HP HIGH POINT LP LOW POINT ABBREVIATIONS PROJECT CONTACTS INDEX AG L E R O C K N G I N E E R I N G DE S I G N E D B Y : DR A W N B Y : PR O J E C T N O . AP P R O V E D B Y : CA D N A M E : RE V I S I O N : DA T E : SC A L E : KU R T R O L A N D PA U L S N A R R N/ A DE S C R I P T I O N DA T E RE V I S I O N S 1 2 3 4 5 6 SH E E T N O . 1 CO V E R SH E E T N A M E AT T E N T I O N Th i s d o c u m e n t o r a n y p a r t th e r e o f i n d e t a i l o r d e s i g n co n c e p t i s t h e p r o p e r t y o f Ea g l e R o c k E n g i n e e r i n g a n d sh a l l n o t b e c o p i e d i n a n y fo r m w i t h o u t t h e w r i t t e n au t h o r i z a t i o n o f E a g l e R o c k En g i n e e r i n g . JU L I E L E H M A N N E GENERAL NOTES W E S N PROJECT LOCATION 16 4 1 0 S 3 R D W W MAIN ST 1.ALL NEW ELECTRICAL FACILITIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENT ROCKY MOUNTAIN POWER SERVICE POLICY. 2.ALL PVC ELECTRIC CONDUITS SHALL BE PVC SCHEDULE 40. ALL FIBERGLASS CONDUITS SHALL MEET ROCKY MOUNTAIN POWER'S MARKING AND STRENGTH RATINGS REQUIREMENTS. CONDUIT DIAMETERS SHALL MEET ROCKY MOUNTAIN POWER'S DESIGN. ALL ELBOWS SWEEP RADII SHALL BE 36”, 48” OR 60” DEPENDING ON ROCKY MOUNTAIN POWER'S DESIGN. 3.TRENCH EXCAVATION AND CONDUIT PLACEMENT SHALL BE IN ACCORDANCE WITH ROCKY MOUNTAIN POWER SERVICE POLICY SPECIFICATIONS AND IN ACCORDANCE WITH OSHA STANDARDS. CONDUIT TRENCH DEPTHS SHALL BE BETWEEN 36” AND 48” (NOT TO EXCEED 60”) AND INCLUDE THE REQUIRED SAND PLACEMENT BELOW AND ABOVE THE PLACED CONDUIT. 4.THE DEVELOPER/ENGINEER SHALL PROVIDE ALL STAKING AND LAYOUT OF NEW ELECTRICAL FACILITIES INCLUDING POWER POLES. 5.THE CONTACTOR SHALL RETAIN AND PROTECT ALL EXISTING POWER POLES AND ELECTRICAL FACILITIES DURING CONSTRUCTION. 6.THE DEVELOPER AND ENGINEER SHALL COORDINATE ALL ELECTRICAL CONSTRUCTION WITH ROCKY MOUNTAIN POWER. 7.CLEARANCE BETWEEN OVERHEAD POWER AND NEW BUILDING STRUCTURES SHALL BE MAINTAINED MEETING THE CURRENT ROCKY MOUNTAIN POWER SERVICE POLICY. 8.SEE ROCKY MOUNTAIN POWER ELECTRICAL SITE PLAN FOR OFF-SITE AND ON-SITE ELECTRICAL , LAYOUT, AND INSTALLATION DETAILS. 9.OWNER SHALL BEAR ALL COSTS TO RELOCATE OR REMOVE EXISTING POWER POLES, LIGHT POLES, ANCHOR GUYS AND MISCELLANEOUS ELECTRICAL FACILITIES. 10.A 15 FOOT WIDE PUBLIC UTILITY EASEMENT IS PERPETUALLY RESERVED WITHIN EACH LOT ALONG ALL ROAD FRONTAGES FOR THE USE OF PUBLIC UTILITIES OR ANY OTHER USES AS DESIGNATED IN ACCORDANCE WITH THE PLAT FOR THIS SUBDIVISION. ELECTRICAL NOTES: MA D I S O N S Q U A R E VI C I N I T Y M A P / N O T E S / I N D E X / A B B R E V I A T I O N S / CO N T A C T S PR E P A R E D F O R : C O R Y S O R E N S O N 2/ 2 / 2 1 N 3 R D W N 4 T H W S 4 T H W SALEM AVE 20 1 2 3 20 1 2 3 M A D I S O N S Q U A R E P & P JA N U A R Y 2 2 , 2 0 2 1 CAT CAT GA S GASGAS W W W ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD CAT EXISTING 30' X 84' FOUR-PLEX TO BE REMODELED EXISTING SHED EXISTING SSMH RIM=4864.72 E INV=4846.27 EXISTING SSMH RIM=4863.78 E INV=4846.28 W INV=4846.18 EXISTING SSMH RIM=4864.41 W INV=4846.96 EXISTING SDMH RIM=4864.66 INV=4846.46 EXISTING SDMH RIM=4864.92 INV=4845.99 CAT CAT CAT CAT CAT CAT CAT 6.5' GA S GAS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD CAT CAT CAT CAT CAT CAT CATCAT CAT CAT W W W GAS EXISTING SHED EXISTING 30' X 84' FOUR-PLEX N0 0 ° 1 5 ' 0 2 " W 1 8 0 . 0 0 ' N89° 44' 58"E 179.49' S0 0 ° 1 5 ' 0 2 " E 1 8 0 . 0 0 ' S89° 44' 58"W 194.00' W W E S N 10' SCALE: 1" = 20' 20'0 20' DE S I G N E D B Y : DR A W N B Y : PR O J E C T N O . SU R V E Y E D B Y : CA D N A M E : RE V I S I O N : DA T E : SC A L E : KU R T R O L A N D TE R R Y H A N S E N 1" = 2 0 ' DE S C R I P T I O N DA T E RE V I S I O N S 1 2 3 4 5 6 SH E E T N O . 2 C- 1 SH E E T N A M E AT T E N T I O N Th i s d o c u m e n t o r a n y p a r t th e r e o f i n d e t a i l o r d e s i g n co n c e p t i s t h e p r o p e r t y o f Ea g l e R o c k E n g i n e e r i n g a n d sh a l l n o t b e c o p i e d i n a n y fo r m w i t h o u t t h e w r i t t e n au t h o r i z a t i o n o f E a g l e R o c k En g i n e e r i n g . JU L I E L E H M A N N EAG L E R O C K N G I N E E R I N G CI V I L P L A N N I N G S U R V E Y I N G ID A H O F A L L S ( 2 0 8 ) 5 4 2 - 2 6 6 5 R E X B U R G ( 2 0 8 ) 3 5 9 - 2 6 6 5 MA D I S O N S Q U A R E EX I S T I N G C O N D I T I O N S / D E M O L I T I O N P L A N PR E P A R E D F O R : C O R Y S O R E N S O N 16 4 1 0 2/ 2 / 2 1 EXISTING GROUND CONTOUR4727 EXISTING TREE TO BE REMOVED REMOVE EXISTING FRENCH DRAIN IN ACCORDANCE WITH STATE STANDARDS (REMOVE/FILL & COMPACT PER STD.) TREES TO BE REMOVED TREES TO BE REMOVED TREES TO BE REMOVED FENCES TO BE REMOVED FENCES TO BE REMOVED ASPHALT TO BE REMOVED AND NEW CURB CUT EXISTING STORM DRAIN MAIN EXISTING SANITARY SEWER MAIN EXISTING GAS LINE PROJECT BOUNDARY LINE OVERHEAD POWER LINE EXISTING WATER MAIN EXISTING FENCE EXISTING UNDERGROUND CABLECAT ( 8''SS W POWER LINE EXISTING WATER VALVE EXISTING HYDRANT EXISTING WATER METER EXISTING WATER SPIGOT EXISTING MANHOLE EXISTING POWER POLE 8" SEWER MAIN( 8''SS 4" SEWER SUPPLY 6" WATER MAIN6''W EXISTING CURB AND GUTTER PROPOSED ASPHALT DRAINAGE FLOW ARROW0.75% PROPOSED CONCRETE 62.80 TBC PROPOSED ELEVATION 1-1/2" WATER SUPPLY1-1/2''W 2" WATER SUPPLY2''W 4" WATER SUPPLY4''W4''W 20 1 2 3 20 1 2 3 M A D I S O N S Q U A R E P & P JA N U A R Y 2 2 , 2 0 2 1 EXISTING SIDEWALK AND STAIRS TO BE REMOVED EXISTING CURB TO BE REMOVED EXISTING CONCRETE TO BE REMOVED EXISTING CONCRETE TO BE REMOVED MAIN STREET MOVE UNKNOWN RISER. WATER METER AND WATER VALVE DESCRIPTIONLINETYPE LEGEND N0 0 ° 1 4 ' 5 1 " W 26 3 9 . 9 3 ' SOUTHWEST CORNER SECTION 19, TOWNSHIP 6 NORTH, RANGE 40 EAST, BOISE MERIDAIN CPF INSTRUMENT NUMBER____________ SOUTHEAST CORNER SECTION 19, TOWNSHIP 6 NORTH, RANGE 40 EAST, BOISE MERIDAIN CPF INSTRUMENT NUMBER____________ NORTHWEST CORNER SECTION 19, TOWNSHIP 6 NORTH, RANGE 40 EAST, BOISE MERIDAIN CPF INSTRUMENT NUMBER____________ 1666.86' N89°44'58"E 2637.10' SECTION LINE BASIS OF BEARING N0 0 ° 1 5 ' 0 2 " W 65 . 9 9 ' 970.24' SECTION LINE EXISTING SIDEWALK TO BE REMOVED AND REPLACED BY 8' SIDEWALK AS PER CITY OF REXBURG EXISTING SIDEWALK TO BE REMOVED GA S GASGAS W W W ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS EXISTING 30' X 84' FOUR-PLEX TO BE REMODELED EXISTING SHED 6.5' 6.25'± 27.66' 1 27 26 25 24 23 21' 39 40 5-9'X22' 2-9'X20' 24' 14 - 9'X16' 2 3 4 6 7 8 9 10 12 13 28 11 - 9'X20' 34 35 37 9'24'16' 151617181920 29 30 31 8 - 9'X20' 21 32 36 15 UNITS 2 UNITS 4 UNITS 21.5' 20' 5 11 14 22 33 38 41 42 GA S GAS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD EXISTING SSMH RIM=4864.72 E INV=4846.27 EXISTING SSMH RIM=4863.78 E INV=4846.28 W INV=4846.18 EXISTING SSMH RIM=4864.41 W INV=4846.96 EXISTING SDMH RIM=4864.66 INV=4846.46 EXISTING SDMH RIM=4864.92 INV=4845.99 6"X 4" TEE W/THRUST BLOCK INSTALL DOG HOUSE MH RIM=4864.1 ( MATCH EXISTING) N INV = 4846.75 E & W INV=4846.65 (FIELD VERIFY) ( 4''SS ( 4''SS ( 4''SS ( 4''SS ( 4''SS ( 4''SS INSTALL SSMH RIM=4862.50 INV OUT = 4847.48 24' PLUG & THRUST BLOCK INSTALL 2 - 2" X 1" TEES ( 4''SS ( 4''SS 2' ' W 4''SS )4''SS ) 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W 4''W ( 4''SS ( 4''SS 6"X4" TEE & 6" X 2" REDUCER & THRUST BLOCK 1-1/2''W 1-1/2''W 1-1/2''W 9' ( 4''SS ( 4''SS9' ( 4''SS ( 4''SS 1-1/2''W 1-1/2''W 1-1/2''W 1-1/2''W 6' ' W 1''W 1''W1''W 1''W TRASH W/ ENCLOSURE 4''SS )4''SS ) IRR ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S WATERLINES TO BE PLACED AS FAR AWAY FROM THE BUILDING AS POSSIBLE. DECK INSTALL CB #1 GRATE=62.50 S INV=59.50 W W W GAS EXISTING SHED INSTALL CB #3 GRATE=62.40 S INV=59.12 N INV OUT=59.02 EXISTING 30' X 84' FOUR-PLEX 12 ' ' S D ) INSTALL CB #2 GRATE=62.50 S INV IN=59.36 N INV OUT=59.26 12 ' ' S D ) 6.5' MIN. LANDSCAPE COMPANY TO CONNECT AND COMPLETE THE WATER SYSTEM FOR LANDSCAPING 10' 0.73' 6.25'± 14'± LANDSCAPE COMPANY TO CONNECT AND COMPLETE THE WATER SYSTEM FOR LANDSCAPING 6 ' RAMP 4 8 6 4 4 8 6 4 4 8 6 4 4864 4862 4864 4864 4868 THICKENED EDGE SIDEWALK SEE SHEET D-1 (TYP) NYLOPLAST SDMH (SEE TABLE 1) W INSTALL NEW SIDEWALK INSTALL NEW SIDEWALK THICKENED EDGE SIDEWALK SEE SHEET D-1 (TYP) W E S N 10' SCALE: 1" = 20' 20'0 20' DE S I G N E D B Y : DR A W N B Y : PR O J E C T N O . SU R V E Y E D B Y : CA D N A M E : RE V I S I O N : DA T E : SC A L E : KU R T R O L A N D TE R R Y H A N S E N 1" = 1 0 ' DE S C R I P T I O N DA T E RE V I S I O N S 1 2 3 4 5 6 SH E E T N O . 3 C- 2 SH E E T N A M E AT T E N T I O N Th i s d o c u m e n t o r a n y p a r t th e r e o f i n d e t a i l o r d e s i g n co n c e p t i s t h e p r o p e r t y o f Ea g l e R o c k E n g i n e e r i n g a n d sh a l l n o t b e c o p i e d i n a n y fo r m w i t h o u t t h e w r i t t e n au t h o r i z a t i o n o f E a g l e R o c k En g i n e e r i n g . JU L I E L E H M A N N EAG L E R O C K N G I N E E R I N G CI V I L P L A N N I N G S U R V E Y I N G ID A H O F A L L S ( 2 0 8 ) 5 4 2 - 2 6 6 5 R E X B U R G ( 2 0 8 ) 3 5 9 - 2 6 6 5 MA D I S O N S Q U A R E OV E R A L L U T I L I T Y S I T E P L A N / G R A D I N G P L A N PR E P A R E D F O R : C O R Y S O R E N S O N 16 4 1 0 NOTES: 1. CURRENT ZONING: MIXED USE (MU) MIN. FRONT BUILDING SET BACK = 0' - 10' MIN. SIDE YARD SETBACK: 6' BACKYARD SETBACK: 6' LANDSCAPING = 21% LOT AREA: 0.594 ACRES (25,895 SF) REQUIRED PARKING = 2 STALLS PER UNIT/42 PARKING = 42 STALLS INCLUDING 2 GARAGES LANDSCAPING REQUIRED: 10% BUILDING AREA: 10,765 SF BUILDING HEIGHT = 24' 2.6" WL SHALL BE DI CLASS 50 AND SHALL INCLUDE ALL APPURTENANCES & THRUST BLOCKS REQUIRED FOR COMPLETE INSTALLATION MEETING CITY STANDARDS. THE WATER SERVICES SHALL BE POLY PIPE AND SHALL INCLUDE ALL APPURTENANCES & THRUST BLOCKS REQUIRED FOR COMPLETE INSTALLATION. 3.CONTRACTOR TO BE AWARE THERE ARE NUMEROUS UTILITIES WITHIN AND SHALL CALL FOR LOCATES PRIOR TO EXCAVATION. THERE WERE NO RECORDED EASEMENTS FOUND ON SAID UTILITIES; HOWEVER EASEMENTS ARE NOW WRITTEN FOR THE SANITARY SEWER AND WATER MAINS WITHIN THIS SITE PLAN. 4.FIRE PROTECTION TO MEET NFPA 13R. 2/ 2 / 2 1 REPLACE EXISTING SIDEWALK WITH 8' SIDEWALK AS PER CITY OF REXBURG NEW CURB CUT 62.80 TBC PROPOSED ELEVATION EXISTING GROUND CONTOUR4727 EXISTING STORM DRAIN MAIN EXISTING SANITARY SEWER MAIN EXISTING GAS LINE PROJECT BOUNDARY LINE OVERHEAD POWER LINE EXISTING WATER MAIN EXISTING FENCE EXISTING UNDERGROUND CABLECAT ( 8''SS W POWER LINE EXISTING WATER VALVE EXISTING HYDRANT EXISTING WATER METER EXISTING MANHOLE EXISTING POWER POLE 8" SEWER MAIN( 8''SS 4" SEWER SUPPLY 6" WATER MAIN6''W 1-1/2" WATER SUPPLY1-1/2''W EXISTING CURB AND GUTTER PROPOSED ASPHALT DRAINAGE FLOW ARROW0.75% PROPOSED CONCRETE NEW TREE NEW BUSH 2" WATER SUPPLY2''W 4" WATER SUPPLY4''W ( 12"SD G 1" WATER SUPPLY1''W 20 1 2 3 20 1 2 3 M A D I S O N S Q U A R E P & P JA N U A R Y 2 2 , 2 0 2 1 STORM POND STORM POND STORM POND STORM POND SEE SHEET C-3 FOR GRADES STORM POND SEE SHEET C-3 FOR GRADES STORM POND SEE SHEET C-3 FOR GRADES BLDG 1 BLDG 2 FF 64.19 FF 65.14 4" FIRE LINE 4" POTABLE WATER LINE 1 1/2" IRRIGATION LINE 1 1/2" IRRIGATION LINE LINETYPE LEGEND NEW 18" LIP UP CURB & GUTTER NEW 18" LIP DOWN CURB & GUTTER REPLACE EXISTING SIDEWALK WITH 8' SIDEWALK AS PER CITY OF REXBURG INSTALL NEW SIDEWALK CAT CAT GA S GASGAS W W W ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS CAT EXISTING 30' X 84' FOUR-PLEX TO BE REMODELED EXISTING SHED EXISTING SSMH RIM=4864.72 E INV=4846.27 EXISTING SSMH RIM=4863.78 E INV=4846.28 W INV=4846.18 EXISTING SSMH RIM=4864.41 W INV=4846.96 EXISTING SDMH RIM=4864.66 INV=4846.46 EXISTING SDMH RIM=4864.92 INV=4845.99 CAT CAT CAT CAT CAT CAT CAT 6.25'± 0+ 0 0 1+ 0 0 2+ 0 0 2+ 2 0 0+ 5 0 1+ 5 0 1 27 26 25 24 23 39 40 5-9'X22' 2-9'X20' 14 - 9'X16' 2 3 4 6 7 8 9 10 12 13 28 11 - 9'X20' 34 35 37 151617181920 29 30 31 8 - 9'X20' 21 32 36 15 UNITS 2 UNITS 4 UNITS 5 11 14 22 33 38 41 42 GA S GAS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 8''SS ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD ( 12''SD 24' TBC 64.28 1.5% 63.00 DECK 64.00 64.00 63.00 OIL 63.30 OIL 63.25 OIL 63.70 TBC 64.28 TBW 63.78 OIL 63.40 OIL 63.27 OIL 62.98 OIL 62.80 TBC 63.72 TFW/OIL 63.20 2. 0 % 2.0% FRONT OF GARAGE = 63.36 58 L . F . 1 2 " S D @ 0 . 2 4 % 62.00 61.00 INSTALL CB #1 GRATE=62.50 S INV=59.50 W W W GAS EXISTING SHED INSTALL CB #3 GRATE=62.40 S INV=59.12 N INV OUT=59.02 TFW 63.78 TFW 63.70 EO 63.20 OIL 63.10GRADE BREAK 1. 5 % 1.5% 2. 0 % 2. 0 % STORM POND STAIRWELL 64.00 58 L . F . 1 2 " S D @ 0 . 2 4 % 61.00 ADS STORM TECH INFILTRATION SYSTEM - SEE TABLE 1 TFW/TBC 64.20 OIL 63.70 OIL 63.70 TFW 63.70 EO 63.20 OIL 63.10 BASEMENT=60.79 TOP FLOOR=69.91 GRADE BREAK 1. 5 % 1.5% 2.0% STAIRWELL OIL 63.10 64.00 62.00 OIL 63.40 EXISTING 30' X 84' FOUR-PLEX 12 ' ' S D ) INSTALL CB #2 GRATE=62.50 S INV IN=59.36 N INV OUT=59.26 STORM AREA 1 34,920 SF GRADE BREAK 1. 5 % 1.5% STAIRWELL 62 . 0 0 60 . 0 0 OIL 63.70 OIL 63.70 OIL 63.10GRADE BREAK 1. 5 % 1.5%2. 0 % 2. 0 % STAIRWELL TBW 63.28 TFW/OIL 63.20 FRONT OF GARAGE = 63.36 12 ' ' S D ) 6.5' MIN. 10' 0.73' 6.25'± 14'± TBC 63.45 TBW 63.78 1. 5 % 2. 0 % TFW 63.70 TFW/OIL 63.20 TBW 63.78 TBW 63.28 OIL 62.92 OIL 62.92 OIL 62.75 TBW 63.28 TBW 63.28 OIL 63.12 OIL 63.00 TBC 63.60 OIL 62.80 TBW 63.87 TBW 65.00 TBC 63.85 TBC 63.90 4 8 6 4 4 8 6 4 4 8 6 4 4864 4862 4864 4864 4868 64 . 0 0 64 . 0 0 64 . 0 0 OIL 63.20 TBW 63.78 THICKENED EDGE SIDEWALK SEE SHEET D-1 (TYP) TFW 64.20 TBW 64.30 TFW 64.20 TBW 64.30 TFW 64.20 TBW 64.30 TFW 64.20 TBW 64.30 TFW 64.20 TBW 64.30 OIL 63.70 TBW 64.30 TBC 63.60 64 . 0 0 63 . 0 0 64 . 0 0 63 . 0 0 NYLOPLAST SDMH (SEE TABLE 1) 2.0% W INSTALL NEW SIDEWALK INSTALL NEW SIDEWALK 62.00 61.00 61 . 0 0 THICKENED EDGE SIDEWALK SEE SHEET D-1 (TYP) W E S N 10' SCALE: 1" = 20' 20'0 20' DE S I G N E D B Y : DR A W N B Y : PR O J E C T N O . SU R V E Y E D B Y : CA D N A M E : RE V I S I O N : DA T E : SC A L E : KU R T R O L A N D TE R R Y H A N S E N 1" = 1 0 ' DE S C R I P T I O N DA T E RE V I S I O N S 1 2 3 4 5 6 SH E E T N O . 4 C- 3 SH E E T N A M E AT T E N T I O N Th i s d o c u m e n t o r a n y p a r t th e r e o f i n d e t a i l o r d e s i g n co n c e p t i s t h e p r o p e r t y o f Ea g l e R o c k E n g i n e e r i n g a n d sh a l l n o t b e c o p i e d i n a n y fo r m w i t h o u t t h e w r i t t e n au t h o r i z a t i o n o f E a g l e R o c k En g i n e e r i n g . JU L I E L E H M A N N EAG L E R O C K N G I N E E R I N G CI V I L P L A N N I N G S U R V E Y I N G ID A H O F A L L S ( 2 0 8 ) 5 4 2 - 2 6 6 5 R E X B U R G ( 2 0 8 ) 3 5 9 - 2 6 6 5 MA D I S O N S Q U A R E ST O R M P L A N PR E P A R E D F O R : C O R E Y S O R E N S O N 16 4 1 0 NOTES: SEE NOTES IN STORM TABLES FOR STORM DRAINAGE AND ROOF DRAIN GUTTERS. CONTRACTOR TO INSTALL A STORM TECH MC3500 SYSTEM WITH NYLOPLAST INLET AND OUTLET PER MANUFACTURERS DRAWINGS AND SPECIFICATIONS TO BE SUBMITTED TO EAGLE ROCK ENGINEERING FOR APPROVAL PRIOR TO CONSTRUCTION. MINIMUM REQUIRED STORAGE: 3050 CF. (SEE TABLE 1) 20 1 2 3 20 1 2 3 M A D I S O N S Q U A R E P & P JA N U A R Y 2 2 , 2 0 2 1 FF 64.19 FF 65.47 NORTHEAST STORM POND (SEE TABLE 2) WEST STORM POND (SEE TABLE 2) SOUTHEAST STORM POND (SEE TABLE 2) 2/ 2 / 2 1 4846 4848 4850 4852 4854 4856 4858 4860 4862 4864 4866 4868 4846 4848 4850 4852 4854 4856 4858 4860 4862 4864 4866 4868 0+00 1+00 2+00 2+40 INSTALL SSMH #2 STA:1+87.47 RIM=4862.50 S INV OUT=4847.48 182 LF OF 12" PVC @ 0.40% INSTALL SSMH #1 (IN EXISTING LINE - DOG HOUSE MH) STA:0+05.40 RIM=4864.10 N INV IN=4846.75 E & W INV=4846.65 (FIELD VERIFY) OI L S T A : 0 + 5 0 . 9 0 EL E V : 4 8 6 3 . 0 4 ' OI L S T A : 0 + 5 6 . 8 5 EL E V : 4 8 6 2 . 9 4 ' GR A T E S T A : 0 + 7 6 . 0 1 EL E V : 4 8 6 2 . 5 0 ' OI L S T A : 1 + 0 2 . 8 7 EL E V : 4 8 6 3 . 1 0 ' OI L S T A : 1 + 6 0 . 4 1 EL E V : 4 8 6 3 . 1 0 ' GR A T E S T A : 1 + 3 2 . 3 8 EL E V : 4 8 6 2 . 5 0 ' GR A T E S T A : 1 + 9 0 . 3 8 EL E V : 4 8 6 2 . 4 0 ' -1.68% -2.30%2.23%-2.03%2.14%-2.34% 57 LF OF 12" PVC @ 0.25% 58 LF OF 12" PVC @ 0.24% INSTALL 24.32' OF 6" WATERLINE 24.02' OF EXISTING 2" WATERLINE INSTALL CB #2 GRATE=62.50 S INV IN=59.36 N INV OUT=59.26 INSTALL CB #3 GRATE=62.40 12" INV IN=59.12 12" INV OUT=59.02 TB W S T A : 0 + 3 6 . 3 9 EL E V : 4 8 6 3 . 6 9 ' EO S T A : 2 + 1 6 . 3 2 EL E V : 4 8 6 3 . 1 0 ' -4.4 8 % INSTALL 2 - 1" WATER SERVICES WITH ALL APPURTENANCES AND THRUST BLOCK HOT TAP CONNECTION TO EXISTING WATER MAIN AND THRUST BLOCK INSTALL 6" X 4" TEE FOR FIRELINE W/THRUST BLOCK INSTALL 6" X 4" TEE W/THRUST BLOCK (POTABLE WATER LINE) INSTALL 6" X 2" REDUCER & THRUST BLOCK ASPHALT INSTALL CB #1 GRATE=62.50 N INV OUT=59.50 6' MIN BURY 1 1 2" WATER SERVICE CONNECTION EAST & WEST PER CITY STANDARDS (LANDSCAPE WATER) INSTALL NYLOPLAST MH STATION: 1+93.37 RIM=62.40 12" INV IN=59.01 24" INV OUT=58.01 TO ADS CHAMBER SYSTEM ADS STORM TECH INFILTRATION SYSTEM - SEE TABLE 1 5 LF 24" PVC @ 0.08% 5 LF 12" PVD @ 0.22% 2.69% GAS GA S W W W ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S CA T EX I S T I N G 30 ' X 8 4 ' FO U R - P L E X TO B E RE M O D E L E D EX I S T I N G S D M H RI M = 4 8 6 4 . 6 6 IN V = 4 8 4 6 . 4 6 CA T CA T CA T CA T CA T CA T 0+00 1+00 2+00 2+200+50 1+50 1 27 26 25 24 23 39 40 5- 9 ' X 2 2 ' 2- 9 ' X 2 0 ' 1 4 - 9 ' X 1 6 ' 2 3 4 6 7 8 9 10 12 13 28 11 - 9 ' X 2 0 ' 34 35 37 15 16 17 18 19 20 293031 8 - 9 ' X 2 0 ' 21 32 36 15 U N I T S 2 U N I T S 4 U N I T S 5 11 14 22 33 38 4142 GAS ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 8 ' ' S S ( 1 2 ' ' S D ( 1 2 ' ' S D ( 1 2 ' ' S D ( 1 2 ' ' S D ( 4 ' ' S S ( 4 ' ' S S ( 4 ' ' S S ( 4 ' ' S S ( 4 ' ' S S ( 4 ' ' S S IN S T A L L S S M H RI M = 4 8 6 2 . 5 0 IN V O U T = 4 8 4 7 . 4 8 24 ' ( 4 ' ' S S ( 4 ' ' S S 2''W 4' ' S S ) 4' ' S S ) 4' ' W 4' ' W 4' ' W 4' ' W 4' ' W 4' ' W 4' ' W 4' ' W 4' ' W 4' ' W 4' ' W 4' ' W ( 4 ' ' S S ( 4 ' ' S S 1- 1 / 2 ' ' W 1- 1 / 2 ' ' W 1- 1 / 2 ' ' W ( 4 ' ' S S ( 4 ' ' S S ( 4 ' ' S S ( 4 ' ' S S 1- 1 / 2 ' ' W 1- 1 / 2 ' ' W 1- 1 / 2 ' ' W 1- 1 / 2 ' ' W 6''W 1' ' W 1' ' W 1' ' W 1' ' W 4' ' S S ) 4' ' S S ) IR R ( 8''SS( 8''SS( 8''SS( 8''SS( 8''SS( 8''SS( 8''SS( 8''SS( 8''SS TB C 64 . 2 8 1 . 5 % 63 . 0 0 DE C K 64 . 0 0 64 . 0 0 63 . 0 0 OI L 63 . 3 0 OI L 63 . 2 5 OI L 63 . 7 0 TB C 64 . 2 8 TB W 63 . 7 8 OI L 63 . 4 0 OI L 63 . 2 7 OI L 62 . 9 8 OI L 62 . 8 0 TB C 63 . 7 2 TF W / O I L 63 . 2 0 2.0% 2.0% FR O N T O F GA R A G E = 6 3 . 3 6 58 L.F. 12" SD @ 0.24%62 . 0 0 61 . 0 0 IN S T A L L C B # 1 GR A T E = 6 2 . 5 0 S I N V = 5 9 . 5 0 W W W GA S IN S T A L L C B # 3 GR A T E = 6 2 . 4 0 S I N V = 5 9 . 1 2 N I N V O U T = 5 9 . 0 2 TF W 63 . 7 8 TF W 63 . 7 0 EO63 . 2 0 OI L 63 . 1 0 GR A D E BR E A K 1.5% 1 . 5 % 2.0%2.0% ST O R M P O N D ST A I R W E L L 64 . 0 0 58 L.F. 12" SD @ 0.24% 61 . 0 0 AD S S T O R M T E C H I N F I L T R A T I O N SY S T E M - S E E T A B L E 1 TF W / T B C 64 . 2 0 OI L 63 . 7 0 OI L 63 . 7 0 TF W 63 . 7 0 EO63 . 2 0 OI L 63 . 1 0 BA S E M E N T = 6 0 . 7 9 TO P F L O O R = 6 9 . 9 1 GR A D E BR E A K 1.5% 1 . 5 % 2 . 0 % ST A I R W E L L OI L 63 . 1 0 64 . 0 0 62 . 0 0 OI L 63 . 4 0 EX I S T I N G 30 ' X 8 4 ' FO U R - P L E X 12''SD ) IN S T A L L C B # 2 GR A T E = 6 2 . 5 0 S I N V I N = 5 9 . 3 6 N I N V O U T = 5 9 . 2 6 GR A D E BR E A K 1.5% 1 . 5 % ST A I R W E L L 62.00 OI L 63 . 7 0 OI L 63 . 7 0 OI L 63 . 1 0 GR A D E BR E A K 1.5% 1 . 5 % 2.0%2.0% ST A I R W E L L TB W 63 . 2 8 TF W / O I L 63 . 2 0 FR O N T O F GA R A G E = 6 3 . 3 6 12''SD ) 10 ' 0. 7 3 ' 14 ' ± TB C 63 . 4 5 TB W 63 . 7 8 1.5% 2.0% TF W 63 . 7 0 TF W / O I L 63 . 2 0 TB W 63 . 7 8 TB W 63 . 2 8 OI L 62 . 9 2 OI L 62 . 9 2 OI L 62 . 7 5 TB W 63 . 2 8 TB W 63 . 2 8 OI L 63 . 1 2 OI L 63 . 0 0 TB C 63 . 6 0 OI L 62 . 8 0 TB W 63 . 8 7 TB W 65 . 0 0 TB C 63 . 8 5 TB C 63 . 9 0 OI L 63 . 2 0 TB W 63 . 7 8 TH I C K E N E D E D G E SI D E W A L K S E E SH E E T D - 1 ( T Y P ) TF W 64 . 2 0 TB W 64 . 3 0 TF W 64 . 2 0 TB W 64 . 3 0 TF W 64 . 2 0 TB W 64 . 3 0 TF W 64 . 2 0 TB W 64 . 3 0 TF W 64 . 2 0 TB W 64 . 3 0 OI L 63 . 7 0 TB W 64 . 3 0 TB C 63 . 6 0 NY L O P L A S T S D M H (S E E T A B L E 1 ) 2 . 0 % W IN S T A L L N E W SI D E W A L K 62 . 0 0 61 . 0 0 61.00 TH I C K E N E D E D G E SI D E W A L K S E E SH E E T D - 1 ( T Y P ) W E S N 10' SCALE: 1" = 20' 20'0 20' DE S I G N E D B Y : DR A W N B Y : PR O J E C T N O . SU R V E Y E D B Y : CA D N A M E : RE V I S I O N : DA T E : SC A L E : KU R T R O L A N D TE R R Y H A N S E N 1" = 2 0 ' DE S C R I P T I O N DA T E RE V I S I O N S 1 2 3 4 5 6 SH E E T N O . 5 PP - 1 SH E E T N A M E AT T E N T I O N Th i s d o c u m e n t o r a n y p a r t th e r e o f i n d e t a i l o r d e s i g n co n c e p t i s t h e p r o p e r t y o f Ea g l e R o c k E n g i n e e r i n g a n d sh a l l n o t b e c o p i e d i n a n y fo r m w i t h o u t t h e w r i t t e n au t h o r i z a t i o n o f E a g l e R o c k En g i n e e r i n g . JU L I E L E H M A N N EAG L E R O C K N G I N E E R I N G CI V I L P L A N N I N G S U R V E Y I N G ID A H O F A L L S ( 2 0 8 ) 5 4 2 - 2 6 6 5 R E X B U R G ( 2 0 8 ) 3 5 9 - 2 6 6 5 MA D I S O N S Q U A R E PA R K I N G L O T P L A N & P R O F I L E PR E P A R E D F O R : C O R E Y S O R E N S O N 16 4 1 0 LANDSCAPE COMPANY TO CONNECT AND COMPLETE THE WATER SYSTEM FOR LANDSCAPING LANDSCAPE COMPANY TO CONNECT AND COMPLETE THE WATER SYSTEM FOR LANDSCAPING PLUG & THRUST BLOCK INSTALL 2 - 2" TEES 6" TEE & 6"X2" REDUCER & THRUST BLOCK 4" FIRELINE 4" DOMESTIC INSTALL "ONE WAY - DO NOT ENTER" SIGNS 20 1 2 3 20 1 2 3 M A D I S O N S Q U A R E P & P JA N U A R Y 2 2 , 2 0 2 1 THICKENED EDGE SIDEWALK (TYP.) INSTALL DOG HOUSE MH RIM=4864.1 ( MATCH EXISTING) N INV = 4846.75 E & W INV=4846.65 (FIELD VERIFY) 2/ 2 / 2 1 #4 REBAR, 12" OVERLAP VALVE BOX CONC. COLLAR OR EXISTING ROAD ASPHALT PAVEMENT TO BE ENGRAVED THE WORD "WATER" 4 PLACES SCORE CONTROL JOINT ON COVER CUT LINE WATER #4 REBAR, 12" OVERLAP VALVE BOX CONC. COLLAR OR EXISTING ROAD ASPHALT PAVEMENT TO BE ENGRAVED THE WORD "WATER" 4 PLACES SCORE CONTROL JOINT ON COVER CUT LINE WATER -3/4" BEDDING 5' - 0 " M I N 6" M I N 6" M I N PLACE SAFETY FLANGE OR FLANGE WITH BREAK AWAY BOLTS 2" MIN. 8" MAX. ABOVE GRADE DO NOT COVER DRAIN HOLES WITH CONCRETE (2"x8"x12") CONCRETE BLOCK FLANGED JOINT DI LINE TO CITY THRUST BLOCK THRUST BLOCK TO FINISHED GRADE VALVE FINISHED GRADE VALVE BOX SET HYDRANT TEE MJ JOINT VALVE NUT EXTENSION TO WITHIN 6" OF SURFACE MAINLINE 1 CUBIC YARD OF WASHED GRAVEL SURROUNDING DRAIN HOLES 2' SPOOL CONCRETE COLLAR 6" M I N 2' MIN. -3/4" BEDDING 5' - 0 " M I N 6" M I N 6" M I N PLACE SAFETY FLANGE OR FLANGE WITH BREAK AWAY BOLTS 2" MIN. 8" MAX. ABOVE GRADE DO NOT COVER DRAIN HOLES WITH CONCRETE (2"x8"x12") CONCRETE BLOCK FLANGED JOINT DI LINE TO CITY THRUST BLOCK THRUST BLOCK TO FINISHED GRADE VALVE FINISHED GRADE VALVE BOX SET HYDRANT TEE MJ JOINT VALVE NUT EXTENSION TO WITHIN 6" OF SURFACE MAINLINE 1 CUBIC YARD OF WASHED GRAVEL SURROUNDING DRAIN HOLES 2' SPOOL CONCRETE COLLAR 8 6" M I N 2' MIN. B/ 3 MI N . A B REDUCER 12" 14"5'-5" 4'-0" 6" 4" 8" 10"3'-4" 2'-8" 2'-0" 1'-7" 3'-10" 3'-10" 6'-6" 4'-8" 3'-3" 2'-6" 1'-11" 1'-2" 3'-2" 4'-0" 2'-5" 1'-9" 1'-6" 1'-11" 0'-10" 0'-6" 2'-5" 2'-3" 1.WRAP ALL FITTINGS WITH 8 MIL POLYETHYLENE ENCASEMENT TO PREVENT CONCRETE FROM ADHERING TO THE FITTINGS. 2.THRUST BLOCKING CONCRETE TO BE MINIMUM 3000PSI MIX. 3.ALL THRUST BLOCKS ARE TO BE FORMED ON THE VERTICAL PLANES. 4.PLACE THRUST BLOCKS ON ALL WATERLINE BENDS AND TEES. 4'-11" 4'-8" 4'-9" THRUST BLOCK NOTES: 3'-8" 3'-0" 3'-10" 2'-2" 1'-6" 3'-0" 2'-5" 1'-10" 1'-8" 3'-5" 2'-7" 3'-5" 3'-3" 2'-2"2'-9" 2'-1" 1'-7" 0'-10" 1'-9" 1'-9" 1'-7" 90° BEND DIMENSION FOR THRUST BLOCKING TEE TEES & PLUGS A B A 45° BEND & WYES B A B A B REDUCERS & 22° BENDFITTING SIZES BEND B/ 3 MI N . A B REDUCER 12" 14"5'-5" 4'-0" 6" 4" 8" 10"3'-4" 2'-8" 2'-0" 1'-7" 3'-10" 3'-10" 6'-6" 4'-8" 3'-3" 2'-6" 1'-11" 1'-2" 3'-2" 4'-0" 2'-5" 1'-9" 1'-6" 1'-11" 0'-10" 0'-6" 2'-5" 2'-3" 1.WRAP ALL FITTINGS WITH 8 MIL POLYETHYLENE ENCASEMENT TO PREVENT CONCRETE FROM ADHERING TO THE FITTINGS. 2.THRUST BLOCKING CONCRETE TO BE MINIMUM 3000PSI MIX. 3.ALL THRUST BLOCKS ARE TO BE FORMED ON THE VERTICAL PLANES. 4.PLACE THRUST BLOCKS ON ALL WATERLINE BENDS AND TEES. 4'-11" 4'-8" 4'-9" THRUST BLOCK NOTES: 3'-8" 3'-0" 3'-10" 2'-2" 1'-6" 3'-0" 2'-5" 1'-10" 1'-8" 3'-5" 2'-7" 3'-5" 3'-3" 2'-2"2'-9" 2'-1" 1'-7" 0'-10" 1'-9" 1'-9" 1'-7" 90° BEND DIMENSION FOR THRUST BLOCKING TEE TEES & PLUGS A B A 45° BEND & WYES B A B A B REDUCERS & 22° BENDFITTING SIZES BEND 4" M I N 6" M I N 6' - 0 " M I N . B U R Y ( T Y P . ) PIPE BEDDING 4" M I N 6" M I N 6' - 0 " M I N . B U R Y ( T Y P . ) 10 D-1 PIPE BEDDING NATIVE MATERIAL COMPACTED AS PER CITY REQUIREMENTS AND ISPWC TYPICAL STREET/OPEN FIELD ZONE 4 REFER TO IDAPA 58.01.08 IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEM. SITE SPECIFIC APPROVAL FROM DEQ MUST BE SECURED BEFORE ZONE 2 OR 3 INSTALLATIONS ARE MADE. SAME REQUIREMENTS AS ZONE 1 EXCEPT THE SEWER MAIN MUST ALSO BE SUPPORTED ABOVE THE CROSSING TO PREVENT SETTLING. SANITARY SEWER OR STORM DRAIN SEWER LINE ZONE 1 ZONE 2 ZONE 3 SAME REQUIREMENTS AS ZONE 2 EXCEPT THE SEWER MAIN MUST ALSO BE SUPPORTED ABOVE THE CROSSING TO PREVENT SETTLING. A)ONE FULL, UNCUT LENGTH OF WATER PIPE MUST BE CENTERED OVER THE CROSSING SO THAT THE JOINTS ARE AS FAR AS POSSIBLE FROM THE SEWER, AND EITHER; B)SEWER MAIN MUST BE CONSTRUCTED TO WATER MAIN STANDARDS AND PRESSURE TESTED FOR WATER TIGHTNESS FOR A HORIZONTAL DISTANCE OF 10 FEET ON BOTH SIDES OF THE CROSSING, OR; C)EITHER THE SEWER LINE OR THE WATER LINE OR BOTH MUST BE ENCASED IN AT LEAST 4 INCHES OF CONCRETE MEASURED AT THE BELL FOR A HORIZONTAL DISTANCE OF 10 FEET ON BOTH SIDES OF THE CROSSING. A)WATER AND SEWER MUST BE B)SEPARATED BY 18 INCHES, AND ONE FULL, UNCUT LENGTH OF WATER PIPE MUST BE CENTERED OVER THE CROSSING SO THAT THE JOINTS ARE AS FAR AS POSSIBLE FROM THE SEWER. (WATER<18" ABOVE TOP OF SEWER) WATER LINE ZONE 4 REFER TO IDAPA 58.01.08 IDAHO RULES FOR PUBLIC DRINKING WATER SYSTEM. SITE SPECIFIC APPROVAL FROM DEQ MUST BE SECURED BEFORE ZONE 2 OR 3 INSTALLATIONS ARE MADE. SAME REQUIREMENTS AS ZONE 1 EXCEPT THE SEWER MAIN MUST ALSO BE SUPPORTED ABOVE THE CROSSING TO PREVENT SETTLING. SANITARY SEWER OR STORM DRAIN SEWER LINE ZONE 1 ZONE 2 ZONE 3 SAME REQUIREMENTS AS ZONE 2 EXCEPT THE SEWER MAIN MUST ALSO BE SUPPORTED ABOVE THE CROSSING TO PREVENT SETTLING. A)ONE FULL, UNCUT LENGTH OF WATER PIPE MUST BE CENTERED OVER THE CROSSING SO THAT THE JOINTS ARE AS FAR AS POSSIBLE FROM THE SEWER, AND EITHER; B)SEWER MAIN MUST BE CONSTRUCTED TO WATER MAIN STANDARDS AND PRESSURE TESTED FOR WATER TIGHTNESS FOR A HORIZONTAL DISTANCE OF 10 FEET ON BOTH SIDES OF THE CROSSING, OR; C)EITHER THE SEWER LINE OR THE WATER LINE OR BOTH MUST BE ENCASED IN AT LEAST 4 INCHES OF CONCRETE MEASURED AT THE BELL FOR A HORIZONTAL DISTANCE OF 10 FEET ON BOTH SIDES OF THE CROSSING. A)WATER AND SEWER MUST BE B)SEPARATED BY 18 INCHES, AND ONE FULL, UNCUT LENGTH OF WATER PIPE MUST BE CENTERED OVER THE CROSSING SO THAT THE JOINTS ARE AS FAR AS POSSIBLE FROM THE SEWER. (WATER<18" ABOVE TOP OF SEWER) WATER LINE ZO N E 1 ZO N E 2 1' - 6 " 1' - 6 " ZO N E 4 ZO N E 3 FORD S91-607 SADDLE OFFSET CORP. STOPS 15° 12" MIN. RADIUS 45° M I N 60° M A X (PVC) FOR PE PIPE USE SYSTEM THAT DELIVERS AN EQUIVALENT PE CORP STOP FB 1100 SERIES CORPORATION STOP DIRECT TAP W/ CC THREADS SERVICE LINE -3/4 BEDDING 6" M I N 6" M I N MATCH EXISTING LINE SIZE FORD S91-607 SADDLE OFFSET CORP. STOPS 15° 12" MIN. RADIUS 45° M I N 60° M A X (PVC) FOR PE PIPE USE SYSTEM THAT DELIVERS AN EQUIVALENT PE CORP STOP FB 1100 SERIES CORPORATION STOP DIRECT TAP W/ CC THREADS SERVICE LINE -3/4 BEDDING 6" M I N 6" M I N MATCH EXISTING LINE SIZE 4 FT. OR GREATER DEPTH, PIPE DIA. < 24"7 11 A A7 7 LEGEND 1 CONCRETE COLLAR IN PAVED STREET SECTIONS PER SD-508. 2 GRADE RINGS GROUTED WATERTIGHT IN PLACE, NOT TO EXCEED 21" FROM FINISHED SURFACE TO TOP OF CONE. 3 PRECAST MONOLITHIC ECCENTRIC CONE SECTION. (REBAR NOT SHOWN). 4 RAMNEK OR APPROVED GASKETS ALL JOINTS. 5 PROPERLY ALIGN ALL INTERIOR JOINTS. 6 PRECAST CONCRETE MANHOLE-BARREL SECTION (REBAR NOT SHOWN). 7 PRECAST GASKETED HUB RING OR RUBBER GASKETED COLLAR-FLEXIBLE AND WATER TIGHT. 8 REPLACEMENT SURFACING TO MATC FLUSH WITH EXISTING SURFACING (AC SHOWN). 9 FRAME TO BE GROUTED TO GRADE RINGS. 10 FRAME AND COVER PER SD-507. 11 MANHOLE STEPS, SEE NOTE H. 12 CAST IN PLACE MANHOLE BASE. SEE SD-501A FOR PREFABRICATED BASE. 45° SHE L F SHE L F SHE L F FL O W PLAN N.T.S. 891012" 6" ( M I N ) 1 2 3 4 5 6 7 12 11 12 " ( M A X ) 36 " ( M A X ) 24" (MIN) 24 " ( M I N ) 6" (MIN) 4" (MIN) 12 " 48" 16 " ( M A X ) 6 SHELF SLOPE 1" PER FOOT D< 2 4 " 9" (MIN) 4" TYPE 1 BEDDING SECTION A-A N.T.S. NOTES: A OPTIONAL PREFABRICATED MANHOLE BASE WITH APPROVED PIPE CONNECTIONS MAY BE USED WITH ENGINEERS APPROVAL, SEE SD-501A. B PLACE VERTICAL WALL ON UPSTREAM SIDE OF MANHOLE, ROTATED 45 DEGREES. C FOR DIAMETER, D, GREATER THAN 24", SEE SD-502 OR SD-503. D MANHOLE FRAME AND COVER: A.REFER TO DRAWING NO. SD-507. B.FRAME AND COVER SHALL BE FLUSH WITH SLOPE OF PAVEMENT. E WHERE PVC PIPE IS UTILIZED, INSTALL A RUBBER RING OR GASKET COLLAR WHERE THE PIPE IS IN CONTACT WITH MANHOLE BASE AND/OR MANHOLE CHANNEL, IN ORDER TO INSURE A WATERTIGHT SEAL. F EITHER BASE ON SD-501 OR SD-501A MAY BE USED WITH ANY MANHOLE DESIGN. G PROVIDE MANHOLE CONCRETE REINFORCING TO ACCOMMODATE TRAFFIC LOADINGS. H VERIFY WITH ENGINEER REGARDING LOCAL PREFERENCE ON INSTALLATION OF MANHOLE STEPS PRIOR TO ORDERING MATERIALS OR INSTALLATION. 4 FT. OR GREATER DEPTH, PIPE DIA. < 24"7 11 A A7 7 LEGEND 1 CONCRETE COLLAR IN PAVED STREET SECTIONS PER SD-508. 2 GRADE RINGS GROUTED WATERTIGHT IN PLACE, NOT TO EXCEED 21" FROM FINISHED SURFACE TO TOP OF CONE. 3 PRECAST MONOLITHIC ECCENTRIC CONE SECTION. (REBAR NOT SHOWN). 4 RAMNEK OR APPROVED GASKETS ALL JOINTS. 5 PROPERLY ALIGN ALL INTERIOR JOINTS. 6 PRECAST CONCRETE MANHOLE-BARREL SECTION (REBAR NOT SHOWN). 7 PRECAST GASKETED HUB RING OR RUBBER GASKETED COLLAR-FLEXIBLE AND WATER TIGHT. 8 REPLACEMENT SURFACING TO MATC FLUSH WITH EXISTING SURFACING (AC SHOWN). 9 FRAME TO BE GROUTED TO GRADE RINGS. 10 FRAME AND COVER PER SD-507. 11 MANHOLE STEPS, SEE NOTE H. 12 CAST IN PLACE MANHOLE BASE. SEE SD-501A FOR PREFABRICATED BASE. 45° SHE L F SHE L F SHE L F FL O W PLAN N.T.S. 891012" 6" ( M I N ) 1 2 3 4 5 6 7 12 11 12 " ( M A X ) 36 " ( M A X ) 24" (MIN) 24 " ( M I N ) 6" (MIN) 4" (MIN) 12 " 48" 16 " ( M A X ) 6 SHELF SLOPE 1" PER FOOT D< 2 4 " 9" (MIN) 4" TYPE 1 BEDDING SECTION A-A N.T.S. NOTES: A OPTIONAL PREFABRICATED MANHOLE BASE WITH APPROVED PIPE CONNECTIONS MAY BE USED WITH ENGINEERS APPROVAL, SEE SD-501A. B PLACE VERTICAL WALL ON UPSTREAM SIDE OF MANHOLE, ROTATED 45 DEGREES. C FOR DIAMETER, D, GREATER THAN 24", SEE SD-502 OR SD-503. D MANHOLE FRAME AND COVER: A.REFER TO DRAWING NO. SD-507. B.FRAME AND COVER SHALL BE FLUSH WITH SLOPE OF PAVEMENT. E WHERE PVC PIPE IS UTILIZED, INSTALL A RUBBER RING OR GASKET COLLAR WHERE THE PIPE IS IN CONTACT WITH MANHOLE BASE AND/OR MANHOLE CHANNEL, IN ORDER TO INSURE A WATERTIGHT SEAL. F EITHER BASE ON SD-501 OR SD-501A MAY BE USED WITH ANY MANHOLE DESIGN. G PROVIDE MANHOLE CONCRETE REINFORCING TO ACCOMMODATE TRAFFIC LOADINGS. H VERIFY WITH ENGINEER REGARDING LOCAL PREFERENCE ON INSTALLATION OF MANHOLE STEPS PRIOR TO ORDERING MATERIALS OR INSTALLATION. 2-45° BENDS MIN. GRADE 1/4"/FT.(2%) "E" "D" CAP OR PLUG AND INSTALL SERVICE LINE MARKER PER SD-512 (TYP.) ABSOLUTE MIN. GRADE 1/8"/FT.(1%) 4"-1/8 OR 1/16 BEND AS NEEDED MIN. GRADE 1/4"/FT.(2%) "C" "B" "A" FINISH GRADE (SEE NOTE 2) TYPE C TEE OR APPROVED CONNECTION USE 6" OF TYPE I BEDDING ALL AROUND EACH SERVICE. TYPE "E" ALLOWABLE FOR TRENCHES 15 FT. DEEP OR GREATER WITH PRE-APPROVAL BY THE ENGINEER. TYPE "C" SERVICE WILL ONLY BE ALLOWED IF SPECIFICALLY APPROVED BY THE ENGINEER. ALL SERVICE LINES TO BE 4" INSIDE DIAMETER UNLESS OTHERWISE NOTED. 4. 3. 2. 1. NOTES: TYPE E (SEE NOTE 3) 45° TYPE A & D TEE OR APPROVED CONNECTION MIN. GRADE 1/4"/FT.(2% ) LP FINISH GRADE 45 ° M A X . 1/8 LONG RADIUS BEND TYPE B 45 ° M A X . 2-45° BENDS MIN. GRADE 1/4"/FT.(2%) "E" "D" CAP OR PLUG AND INSTALL SERVICE LINE MARKER PER SD-512 (TYP.) ABSOLUTE MIN. GRADE 1/8"/FT.(1%) 4"-1/8 OR 1/16 BEND AS NEEDED MIN. GRADE 1/4"/FT.(2%) "C" "B" "A" FINISH GRADE (SEE NOTE 2) TYPE C TEE OR APPROVED CONNECTION USE 6" OF TYPE I BEDDING ALL AROUND EACH SERVICE. TYPE "E" ALLOWABLE FOR TRENCHES 15 FT. DEEP OR GREATER WITH PRE-APPROVAL BY THE ENGINEER. TYPE "C" SERVICE WILL ONLY BE ALLOWED IF SPECIFICALLY APPROVED BY THE ENGINEER. ALL SERVICE LINES TO BE 4" INSIDE DIAMETER UNLESS OTHERWISE NOTED. 4. 3. 2. 1. NOTES: TYPE E (SEE NOTE 3) 45° TYPE A & D TEE OR APPROVED CONNECTION MIN. GRADE 1/4"/FT.(2% ) LP FINISH GRADE 45 ° M A X . 1/8 LONG RADIUS BEND TYPE B 45 ° M A X . SECTION AA - - A -B 3' - 3 " C1 C1 C3 #4 REBAR BY MANUFACTURER 3 1 / 2 " 2" 3 1/2" 3' - 0 " M I N . 30" INSIDE DIA. BARREL SECTION KNOCKOUTS TYPICAL (4) SIDES 18" DIA. TO RECEIVE UP TO 15" DIA. PIPE 3'-3"2'-0"2'-0" 23 1/2"#4 REBAR BY MANUFACTURER 1 3 / 4 " 6" 6" 7 1 / 4 " REBAR SCHEDULE MARK LOCATION SIZE LENGTH QUANTITY C3 CURB AND BOX 4 2'-0"4 TBC CURB LIP GRATE 9'-6" 3'-3" 90° PIPE BEDDING FOR RIGID PIPE GRANULAR FOUNDATION 90° SHAPED SUBGRADE GRANULAR FOUNDATIONSHAPED SUBGRADE PIPE BEDDING DETAIL FOR FLEXIBLE PIPE COMPACT 1" MAC. BACKFILL IN 6" LAYERS TO 95% OF ASTM D-698 COMPACT APPROVED BEDDING MATERIAL TO 95% OF ASTM D-69812" MAX 6" M I N SHAPED UNDISTURBED SOIL. EXCAVATE FOR BELL HOLES. 3" 6" M I N 12" MAX 90°90° COMPACT 1" MAC. TO 95% OF ASTM D-698 COMPACT APPROVED BEDDING MATERIAL TO 95% OF ASTM D-69812" MAX 6" M I N SHAPED UNDISTURBED SOIL. EXCAVATE FOR BELL HOLES. 3" 6" M I N 12" MAX DE S I G N E D B Y : DR A W N B Y : PR O J E C T N O . SU R V E Y E D B Y : CA D N A M E : RE V I S I O N : DA T E : SC A L E : KU R T R O L A N D TE R R Y H A N S E N DE S C R I P T I O N DA T E RE V I S I O N S 1 2 3 4 5 6 SH E E T N O . 6 D- 1 SH E E T N A M E AT T E N T I O N Th i s d o c u m e n t o r a n y p a r t th e r e o f i n d e t a i l o r d e s i g n co n c e p t i s t h e p r o p e r t y o f Ea g l e R o c k E n g i n e e r i n g a n d sh a l l n o t b e c o p i e d i n a n y fo r m w i t h o u t t h e w r i t t e n au t h o r i z a t i o n o f E a g l e R o c k En g i n e e r i n g . JU L I E L E H M A N N EAG L E R O C K N G I N E E R I N G CI V I L P L A N N I N G S U R V E Y I N G ID A H O F A L L S ( 2 0 8 ) 5 4 2 - 2 6 6 5 R E X B U R G ( 2 0 8 ) 3 5 9 - 2 6 6 5 MA D I S O N S Q U A R E ST O R M P L A N PR E P A R E D F O R : C O R E Y S O R E N S O N 16 4 1 0 GI DUOYEROFEB LLA C GI DUOYEROFEB LLA C 6" 2" ASPHALT 3" 3/4 CRUSHED GRABEL 9" PIT RUN GRAVEL THICKENED EDGE SIDEWALK 6' SIDEWALK 4" 3/4 GRAVEL 4" CONCRETE 11 2-1/2" OF PLANT MIX PAVEMENT UNDISTURBED EARTH 12" OF GRANULAR BORROW/PITRUN 4" OF 3/4" GRAVEL ROADBASE TYPICAL PARKING LOT SECTION13 SANITARY SEWER14 SERVICE LINES 9 STANDARD MANHOLE TYPE A SD-501 12 CATCH BASIN - TYPE 2 6 VALVE & HYDRANT 7 WATER SERVICE LINE CONNECTION 1 TYPICAL WATER LINE PLACEMENT 2 STANDARD TRENCH DETAIL 3 THRUST BLOCKING DETAIL 4 LIP DOWN CURB & GUTTER DETAIL 8 CONCRETE COLLAR FOR VALVE BOX 10 PIPE BEDDING DETAILS 20 1 2 3 20 1 2 3 M A D I S O N S Q U A R E P & P JA N U A R Y 2 2 , 2 0 2 1 5 LIP UP CURB & GUTTER DETAIL 6" 1' 6" AGGREGATE BASE 1'-0" 1'-6" 6" 4"6" 6" 1' 6" AGGREGATE BASE 1'-0" 1'-6" 6" 4" 6" 2/ 2 / 2 1 PR O J E C T I N F O R M A T I O N A0.1 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 0 - 0 1 - C O D E . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 STOR. BEDROOM FAMILY ROOM BATH WIC FAMILY ROOM BATH WIC BEDROOM BEDROOM UNEXCAVATED STORAGE UTILITY STOR. STAIR STAIR STOR. BEDROOM FAMILY ROOM BATH WIC FAMILY ROOM BATH WIC BEDROOMBEDROOM STORAGE UTILITY STOR. UNEX.UNEX. UNIT 102UNIT 101 UNIT 103 UNIT 104 UNIT 105 UNIT 106 UNIT 107 STOR. BEDROOM FAMILY ROOM BATH WIC FAMILY ROOM BATH WIC BEDROOMBEDROOM UNEXCAVATED STORAGE UTILITY STOR. FAMILY ROOM BATH WIC BEDROOM BEDROOM STORAGE UTILITY STOR. UNEX. UNEX. STAIRSTAIR STAIRSTAIRSTAIR BA S E M E N T L E V E L F L O O R P L A N A1.0 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 1 - 0 0 - B F P . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 GENERAL NOTES: BASEMENT LEVEL FLOOR PLAN1 ENTRY ENTRY LIVING ROOM LIVING ROOM DINE KITCHEN KITCHEN UTILITY 1/2 BATH BATHLAUND. BEDROOM MASTER BEDROOM STAIR EXTERIOR STAIR #1 EXTERIOR STAIR #2 WIC PORCH STAIR UNIT 102UNIT 101 UNIT 103 UNIT 104 UNIT 105 UNIT 106 UNIT 107 ENTRY ENTRY LIVING ROOMLIVING ROOM DINE KITCHEN KITCHEN UTILITY 1/2 BATH BATH LAUND. BEDROOM MASTER BEDROOM STAIR WIC PORCH STAIR ENTRY LIVING ROOM DINE KITCHEN UTILITY 1/2 BATH STAIR PORCH ENTRY LIVING ROOM KITCHEN BATHLAUND. BEDROOM MASTER BEDROOM WIC STAIR ENTRY LIVING ROOM KITCHEN BATH LAUND. BEDROOM MASTER BEDROOM WIC STAIR FIRE RISER COVERED PORCH COVERED PORCH PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 1 - 0 1 - L V L 1 . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 LE V E L 1 F L O O R P L A N A1.1 GENERAL NOTES: LEVEL 1 FLOOR PLAN1 STAIR EXTERIOR STAIR #1 EXTERIOR STAIR #2 MASTER BEDROOM LAUN. BEDROOM BEDROOM WIC BATH HALL M. BATH WIC ENTRY LIVING ROOM KITCHEN BATH BEDROOM MASTER BEDROOM WIC UTILITY/ LAUNDRY STAIR MASTER BEDROOM LAUN. BEDROOMBEDROOM WIC BATH HALL M. BATH WIC ENTRY LIVING ROOM KITCHEN BATH BEDROOMMASTER BEDROOM WIC UTILITY/ LAUNDRY UNIT 202UNIT 101 UNIT 203 UNIT 104 UNIT 205 UNIT 206 UNIT 107 STAIR MASTER BEDROOM LAUN. BEDROOMBEDROOM WIC BATH HALL M. BATH WIC ENTRY LIVING ROOM KITCHEN BATH BEDROOMMASTER BEDROOM WIC UTILITY/ LAUNDRY ENTRY LIVING ROOM KITCHEN BATH BEDROOM MASTER BEDROOM WIC UTILITY/ LAUNDRY LE V E L 2 F L O O R P L A N A1.2 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 1 - 0 2 - L V L 2 . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 LEVEL 2 FLOOR PLAN1 GENERAL NOTES: ENTRY LIVING ROOM KITCHEN BATH BEDROOM MASTER BEDROOM WIC UTILITY/ LAUNDRY ENTRY LIVING ROOM KITCHEN BATH BEDROOMMASTER BEDROOM WIC UTILITY/ LAUNDRY EXTERIOR STAIR #1 ENTRY LIVING ROOM KITCHEN BATH BEDROOM MASTER BEDROOM WIC UTILITY/ LAUNDRY ENTRY LIVING ROOM KITCHEN BATH BEDROOMMASTER BEDROOM WIC UTILITY/ LAUNDRY UNIT 302 UNIT 303 UNIT 305 UNIT 306 EXTERIOR STAIR #2 LE V E L 3 F L O O R P L A N A1.3 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 1 - 0 3 - L V L 3 . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 GENERAL NOTES: LEVEL 3 FLOOR PLAN1 ROOF PLAN KEYNOTESROOF NOTES ATTIC VENTILATION CALCULATIONS RO O F P L A N A1.4 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 1 - 0 4 - R P . D W G TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 2 - 0 1 - E L E V . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 FR O N T E X T E R I O R E L E V A T I O N A2.0 WOOD AND PLASTICS THERMAL & MOISTURE DOORS AND WINDOWS FINISHES CONCRETE SITE CONSTRUCTION MASONRY METALS FRONT ELEVATION1 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 2 - 0 1 - E L E V . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 RE A R E X T E R I O R E L E V A T I O N A2.1 WOOD AND PLASTICS THERMAL & MOISTURE DOORS AND WINDOWS FINISHES CONCRETE SITE CONSTRUCTION MASONRY METALS REAR ELEVATION1 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 2 - 0 1 - E L E V . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 LE F T & R I G H T S I D E E X T . E L E V A T I O N S A2.2 WOOD AND PLASTICS THERMAL & MOISTURE DOORS AND WINDOWS FINISHES CONCRETE SITE CONSTRUCTION MASONRY METALS LEFT SIDE ELEVATION1 RIGHT SIDE ELEVATION2 ATTIC ATTIC ATTIC ATTIC ATTIC PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 3 - 0 1 - C S . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 CU T S E C T I O N S & D E T A I L S A3.0 WOOD AND PLASTICS THERMAL & MOISTURE DOORS AND WINDOWS FINISHES CONCRETE SITE CONSTRUCTION MASONRY METALS FRONT ELEVATION1 STAIR ATTIC ATTIC ATTIC EXTERIOR STAIR PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 3 - 0 1 - C S . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 CU T S E C T I O N S & D E T A I L S A3.1 WOOD AND PLASTICS THERMAL & MOISTURE DOORS AND WINDOWS FINISHES CONCRETE SITE CONSTRUCTION MASONRY METALS CUT SECTION1 CUT SECTION2 TYP. 2 x 6 WALL TYP. 2 x 6 WALL TYPICAL EXTERIOR WALL TYP. HORIZONTAL SEPARATION SYSTEM: ROOF - CEILING SYSTEM TYP. 2 x 4 WALL TYP. 2 x 6 WALL TYP. HORIZONTAL SEPARATION SYSTEM: ROOF - CEILING SYSTEM1 HR RATED EXTERIOR WALL TYP. DEMISING WALL A3.4 WA L L T Y P E D E T A I L S PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 3 - 0 4 - W A L L . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 1 WALL TYPE DETAILS DOOR AND WINDOW NOTES GLAZING PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 4 - 0 1 - D O O R . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 WI N D O W / D O O R T Y P E S A4.0 NOTE: ALL DOOR HARDWARE TO BE MEDIUM GRADE SCHLAGE OR EQUAL. NOTE: SEE FLOOR PLANS FOR DIRECTION OF DOOR SWINGS. A HINGES B LOCK SET C PASSAGE SET D PRIVACY SET E DEAD BOLT F CLOSER G WEATHERSTRIP & SILL H STOP J SMOKESEAL & SWEEP K L SLIDING DOOR HARDWARE (PRIVACY LATCH ON BATHS) PULLS & BALL CATCH HARDWARE CODE LEVEL 1 DOOR SCHEDULE - UNITS 101, 104, 107 BASEMENT LEVEL DOOR SCHEDULE - UNITS 101, 104, 107 LEVEL 2 DOOR SCHEDULE - UNITS 101, 104, 107 LEVEL 3 DOOR SCHEDULE - UNITS 302, 303, 305, 306 LEVEL 1 DOOR SCHEDULE - UNITS 102, 103, 105, 106 BASEMENT LEVEL DOOR SCHEDULE - UNITS 102, 103, 105, 106 LEVEL 2 DOOR SCHEDULE - UNITS 202, 203, 205, 206 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 4 - 0 1 - D O O R . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 DO O R S C H E D U L E A4.1 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 4 - 0 2 - D E T A I L S . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 DO O R / W I N D O W D E T A I L S A4.2 1. Floor-Ceiling Assembly - The 1 hr fire rated wood joist floor ceiling assembly shall be constructed of the materials and in the manner specified in the individual L500 series Floor-Ceiling Design in the UL Fire Resistance Directory and shall include the following features. A. Floor System - Lumber or plywood sub-floor with finish floor of lumber, plywood or Floor Topping Mixture* as specified in the individual Floor-Ceiling Design. Max diam. of floor opening is 5 in. B. Wood Joist - Nom 10 in. diam. (or deeper) lumber, steel or combination lumber and steel joist, trusses or structural Wood Members* with bridging as required with ends firestopped. 2. Through Penetrants - Max one metallic pipe or tubing to be installed either concentrically or eccentrically within the firestop system. Pipe or tubing to be rigidly supported on both sides of floor-ceiling assembly. The following types and sizes of metallic pipes or tubing may be used: A. Steel Pipe - Nom 2 in. diam. (or smaller) Schedule 40 (or heavier) steel pipe. B. Iron Pipe - Nom 2 in. diam. (or smaller) cast or ductile iron pipe. C. Copper Tube - Nom 2 in. diam. (or smaller) Type L (or heavier) copper tubing. D. Copper Pipe - Nom 2 in. diam. (or smaller) Regular (or heavier) copper pipe. 3. Pipe Covering - The annular space between the insulated penetrants and periphery of the opening to be min 0 in. (pointed contact) to max 7/8 in. The following types and sizes of pipe coverings may be used with the metallic pipes or tubes. A. Pipe Covering*- Nom 1 in thick hollow cylindrical heavy density (min 3.5 pcf) glass fiber units jacketed on the outside with an all service jacket. Longitudinal joints sealed with metal fasteners or factory-applied self-ceiling lap type. Transverse joints secured with metal fasteners or with butt type supplied with the product. See Pipe and Equipment Covering- Materials (BRGU) category in the Building Materials Directory for names of manufacrurers. Any pipe covering material meeting the aboved specification and bearing the UL Classification Marking with a Flame spread index of 50 or less may be used. B. Tube Insullation-Plastics*- Nom 1/2 in thick acrylonitrile butadiene/polyvinyl chloride (AB/PVC) flexible foam furnished in the form of tubing. See Plastics+++ (QMFZ2) category in the Plastic Recognized Component Directory for names of manufacturers. Any Recognized component tube insulation material meeting the above specification and having a UL 94 Flammability Classification of 94-5VA may be used. 4. Fill, Void or Cavity Materials*-Sealant- Min 3/4 in thickness of sealant app- lied within the annular spaced, flush with top surface of plywood floor. Min 5/8 in thickness of sealant applied within the annular diam. bead of sealant shall be applied at the pipe covering/plywood and pipe covering/gypsum board interface on the top and bottom surfaces of the floor-ceiling assembly. PASSIVE FIRE PROTECTION PARTNERS-4800 DW, 4100NS, 3600EX. + Bearing the UL Recognized Component Mark * Bearing the UL Classification Mark. C. Gypsum Board*- Thickness, type, number of layers and fasteners shall be specified in the individual Floor-Ceiling Design Max diam. of ceiling opening is 5 in. UL System NO. F-C-5053 F Rating - 1 Hr T Rating - 1 Hr Nov. 03, 2017 SECTION A-A PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 4 - 0 3 - P E N . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 TY P I C A L P E N E T R A T I O N D E T A I L S A4.3 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 4 - 0 3 - P E N . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 TY P I C A L P E N E T R A T I O N D E T A I L S A4.4 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 4 - 0 3 - P E N . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 TY P I C A L P E N E T R A T I O N D E T A I L S A4.5 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 4 - 0 3 - P E N . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 TY P I C A L P E N E T R A T I O N D E T A I L S A4.6 PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 4 - 0 3 - P E N . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 TY P I C A L P E N E T R A T I O N D E T A I L S A4.7 TYPICAL TILE INSTALLATION DETAILS NOT TO SCALE W243Gypsum Board Dry-Set Mortar or Latex Portland Cement Mortar Metal Lath Cement Mortar F145Thin-Set DETAIL F122 DETAIL DETAIL STUDS WOOD OR METAL DRY-SET OR LATEX- PORTLAND CEMENT CERAMIC TILE MORTAR BOND COAT • dry interiors over gypsum board. • for dry areas only. • over dry, well-braced wood studs or furring. • over well-braced metal studs. Limitations: • in wet areas such as tub enclosures, use Method B413. • do not use in areas where gypsum board is exposed to temperatures above 125°F. Requirements: • maximum stud spacing—16" o.c. • minimum recommended metal stud depth— 3-5/8". • metal studs—20 gauge (0.039") or heavier. Materials: • gypsum board—ASTM C-36 or C-630. • dry-set mortar—ANSI A118.1. • latex-portland cement mortar— ANSI A118.4. • grout—ANSI A118.6 or A118.7. Preparation by Other Trades: • max. variation in the gypsum board surface—1/4" in 10'-0" from the required plane. • gypsum board joints—treated with tape and joint compound, bedding coat only (no finish coats). Nail heads, one coat only. Installation Specifications: • gypsum board—GA-216. • tile—ANSI A108.5. • grout—ANSI A108.10. CERAMIC TILE MORTAR BED METAL LATH BOND COAT SUBFLOOR CLEAVAGE MEMBRANE Recommended Uses: • for residential use over wood floors that are structurally sound. • where waterproof floor is required, use waterproof membrane meeting A118.10. Contact membrane manufacturer for specific detail. Limitations: • 3/4" min. mortar thickness Requirements: • cleavage membrane • 2.5 lbs/yd2 metal lath (min.), nailed or stapled. • design floor areas over which tile is to be applied to have a deflection not greater than 1/360 of the span when measured under 300 lb. concentrated load (see ASTM C627). Materials: • mortar bed, metal lath, and cleavage membrane—ANSI A108.1A. • bond coat—portland cement paste on a mortar bed that is still workable, or dry-set mortar or latex-portland cement mortar on a cured bed. • grout—ANSI A118.6 or A118.7. Preparation by Other Trades: • subfloor—23/32" exterior glue plywood on joists at 16" o.c. • max. variation in plywood surface shall not exceed 1/4" in 10'-0" from the required plane. Movement Joint (architect must specify type of joint and show location and details on drawings): • movement joints—mandatory according to Method EJ171, page 44. Installation Specifications: • tile—ANSI A108.1A, .1B or .1C. • grout—ANSI A108.10. GYPSUM BOARD CERAMIC TILE WATERPROOF MEMBRANE: SHEET MORTAR BED LATEX-PORTLAND CEMENT MORTAR BOND COAT MAPEILASTIC MEMBRANE CONC. OR CURED Recommended Uses: • wherever a waterproof interior floor is required in conjunction with ceramic tile installed in a thin-set method. • see page 14 NOTE for exterior uses. Limitations: • deflection not to exceed 1/360 of span. • not recommended for severe chemical exposure. Requirements: • design floor areas over which tile is to be applied to have deflection not greater than 1/360 of the span. Make allowance for live load and impact as well as all dead load, including weight of the tile and setting bed. Materials: • specify type of waterproofing; e.g., sheet or liquid applied—ANSI A118.10. • latex-portland cement mortar— ANSI A118.4. • polymer modified tile grout—ANSI A118.7. Preparation by Other Trades: • maximum variation in subfloor—1/4" in 10'-0" from the required plane. • slope subfloor 1/4" per foot to drain. Preparation by Tile Trade: • waterproof membrane—install to comply with pertinent codes and manufacturer's directions. Membrane Installation: • membrane manufacturer's directions. • membrane—ANSI A108.13. Installation Specifications: • tile—ANSI A108.5. Movement Joint (architect must specify type of joint and show location and details on drawings): • movement joints—mandatory according to Method EJ171, page 44. OR LIQUID APPLIED PL O T D A T E : 10 / 1 9 / 2 0 2 0 Q: \ A C A D F i l e \ S O R E N S E N A P A R T M E N T S 2 0 2 0 \ W o r k i n g \ S O R E N S E N _ A P T S _ A 5 - 0 1 - F I N I S H D E T A I L S . d w g TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY REXBURG, ID MA D I S O N S Q U A R E A P A R T M E N T S A N E W P R O J E C T F O R - AUG. - 2020 CITY SUBMITTAL SET 08/2020 MI S C E L L A N E O U S F I N I S H D E T A I L S A5.1 GENERAL STRUCTURAL NOTES GENERAL 1.Construction documents are valid for a single use at the project location and shall not be reused, copied, or reproduced without written approval of the registered design professional in responsible charge. 2.General notes and typical details are provided as a supplement to the construction documents and apply where specific notes and details are not available. Specific notes and structural details shall take precedence over general notes and typical details. Structural requirements shown in the framing plans and in structural details shall take precedence over structural notes indicated in architectural sections. 3.Printed dimensions shall take precedence over scales shown on construction documents. The registered design professional in responsible charge does not warrant the accuracy of scaled dimensions. 4.Approval by the inspector does not imply approval by the registered design professional in responsible charge. Structural specifications that are unclear or ambiguous shall be referred to the registered design professional in responsible charge for interpretation or clarification. 5.The registered design professional in responsible charge assumes no liability for the accuracy, completeness, or code compliance of architectural, electrical, mechanical, drainage, or other non-structural specifications. 6.Omissions in and conflicts between the various elements of the construction documents shall be brought to the immediate attention of the registered design professional in responsible charge and shall be resolved by the same before proceeding with any work involved. 7.Requests for substitutions shall be submitted in writing to the registered design professional in responsible charge and shall include the reasons for the request and any cost differentials. Substitutions are not allowed unless approved in writing by the registered design professional in responsible charge. 8.The contractor shall become familiar with all portions of the construction documents and shall ensure that all subcontractors are familiar with those portions pertaining to their area of work. The contractor shall verify all site conditions, dimensions, elevations, coordinate all doors, windows, non-bearing interior and exterior walls, elevations, slopes, stairs, curbs, drains, recesses, depressions, railings, waterproofing, finishes, chamfer, kerfs, and so forth, and immediately notify the registered design professional in responsible charge regarding actual conditions which are not in agreement with the construction documents. 9.The contractor is responsible for the method, means, and sequence of all structural erection except when specifically noted otherwise in the construction documents. The contractor shall provide temporary shoring and bracing, providing adequate vertical and lateral support during erection. Shoring and bracing shall remain in place until all permanent members are placed and all final connections are completed. 10.The contractor is responsible for standard connections, unless noted otherwise. The contractor shall obtain additional assistance from the registered design professional in responsible charge for non-standard connections. SOIL AND FOUNDATIONS 1.Geotechnical investigations shall conform to 2018 IBC 1803. Excavation, grading and fill shall conform to 2018 IBC 1804. Footings and foundations shall be constructed in accordance with 2018 IBC 1807 through 1810. 2.Where required, the owner shall submit a geotechnical investigation report to the building official in accordance with 2018 IBC 1803. The contractor shall inform the registered design professional in responsible charge if the soil conditions are not consistent with the investigation report and the foundation design data. 3.Excavations for any purpose shall not remove lateral support from any footing or foundation without first underpinning or protecting the footing or foundation against settlement or lateral translation (2018 IBC 1804.1). 4.Excavation outside the foundation shall be backfilled with soil that is free of organic material, construction debris, cobbles and boulders or with a controlled low-strength material (CLSM). The backfill shall be placed in lifts and compacted, in a manner that does not damage the foundation or the waterproofing or dampproofing material (2018 IBC 1804.3). 5.The ground immediately adjacent to the foundation shall have a 5-percent slope away from the building for a minimum distance of 10 feet measured perpendicular to the face of the foundation wall. If physical obstructions or lot lines prohibit 10 feet of horizontal distance, a 5-percent slope shall be provided to an approved alternative method of diverting water away from the foundation. Impervious surfaces within 10 feet of the building foundation shall have a minimum 2-percent slope (2018 IBC 1804.4). 6.Footings and foundations shall be built on undisturbed soil, compacted fill material or CLSM. Compacted fill material and CLSM shall conform to 2018 IBC 1804.6 and 2018 IBC 1804.7, respectively (2018 IBC 1809.2). 7.The top surface of the footings shall be level. The bottom surface of footings is permitted to have a maximum 10-percent slope. Footings shall be stepped where it is necessary to change the elevation of the top surface of the footing or where the surface of the ground has more than a 10-percent slope (2018 IBC 1809.3). 8.The minimum depth of footings below the undisturbed ground surface shall be 12 inches (2018 IBC 1809.4). Foundation walls, piers and other permanent supports shall be extended below the frost line, except where otherwise protected from frost (2018 IBC 1809.5). 9.The placement of footings on or adjacent to 33-percent slopes and steeper shall conform to 2018 IBC 1808.7. 10.Floors of basements shall be placed over base course not less than 4 inches in thickness and a drain shall be installed around the foundation perimeter that consists of gravel or crushed stone containing not more than 10-percent material that passes through a No. 4 sieve (2018 IBC 1805.4.1, 1805.4.2). 11.Backfill shall not be placed against a foundation wall until the wall has sufficient strength and is anchored to the floor above, or is sufficiently braced to prevent damage by the backfill, except bracing is not required for walls supporting less than 4 feet of unbalanced backfill (R404.1.7). CONCRETE 1.Concrete materials, quality control, and construction shall comply with 2018 IBC Chapter 19 and ACI 318-14. 2.Compressive strength (minimum specified at 28 days) 2.1.Footings: 3,000 psi (2018 IBC 1808.8.1) (2,500 psi used in design) 2.2.Interior floor slabs on grade:4,000 psi 2.3.Exterior floor slabs on grade:4,000 psi 2.4.Suspended slabs: 4,000 psi 2.5.Walls: 3,000 psi (2018 IBC 1904.1) for R-2, R-3 occupancies and appurtenances 4,000 psi for other occupancies 3.Materials 3.1.Cements (ASTM C 150). Concrete exposed to freezing and thawing or deicing chemicals shall conform to the maximum water-cementitious material ratios and minimum compressive strength requirements of ACI 318-14 table 19.3.1.1 & 19.3.2.1 3.2.Aggregates (ASTM C 33): nominal maximum size of coarse aggregate shall not be larger than 1/5 the narrowest dimension between forms, nor 1/3 the depth of slabs, nor 3/4 the minimum clear spacing between reinforcing bars or wires, tendons, or ducts (ACI 318-14 26.4.2.1). 3.3.Water used in mixing concrete shall be potable, clean and free from injurious amounts of oils, acids, alkalis, salts, organic materials, or other substances deleterious to concrete or reinforcement (ACI 318-14 26.4.1.3.1.b). 3.4.Admixtures shall be subject to prior approval by the registered design professional in responsible charge (ACI 318-14 26.4.1.4.1.b). 3.5.Concrete exposed to freezing and thawing or deicing chemicals shall be air-entrained with air content indicated in ACI 318-14 Table 19.3.3.1. Tolerance on air content as delivered shall be plus/minus 1.5 percent (ACI 318-14 R26.4.2.1(a)(5)). 4.Steel Reinforcement 4.1.Deformed bars: fy = 60 ksi (ASTM A615) 4.2.Welded plain wire: fy = 60 ksi (ASTM A1064) 4.3.Deformed Bar Anchors (DBA) (ASTM A1064) 4.4.Headed Stud Anchors (HSA) (ASTM A108) 4.5.At the time concrete is placed, reinforcement shall be free from ice, mud, oil, or other nonmetallic coatings that decrease bond (ACI 318-14 26.6.1.2). 4.6.Reinforcement shall be accurately placed and adequately supported before concrete is placed, and shall be secured against displacement (ACI 318-14 26.6.2.2). 4.7.Details of reinforcement shall conform to ACI 318-14 Chapter 25. 5.Minimum concrete cover (ACI 318-14 Table 20.6.1.3.1) 5.1.Concrete cast against and exposed to earth:3 inches 5.2.Concrete exposed to earth or weather: 5.2.1.No. 6 through No. 18 bars: 2 inches 5.2.2.No. 5 bar, W31 wire, and smaller:1.5 inches 5.3.Concrete not exposed to earth or weather: 5.3.1.Slabs, walls, joists No. 11 bar and smaller:0.75 inches 5.3.2.Beams, columns primary reinf., ties, stirrups:1.5 inches 6.Formwork shall conform to ACI 318-14 Sections 26.11 and 26.12 and ACI 347. Forms shall be removed in a manner as not to impair safety and serviceability of the structure. Concrete exposed by form removal shall have sufficient strength not to be damaged by removal operation (ACI 318-14 26.11.2). 7.Conduits, pipes, and sleeves of any material not harmful to concrete and within the limitations of ACI 318-14 20.7 shall be approved by the registered design professional in responsible charge (ACI 318-14 20.7). 8.Construction joints shall be so made and located as not to impair the strength of the structure (ACI 318-14 18.10.9). 9.The thickness of concrete floor slabs on grade shall not be less than 3.5 inches. A 6-mil polyethylene vapor retarder with joints lapped not less than 6 inches (or an equivalent material) shall be placed between the base course or subgrade and the concrete floor slab, except a vapor retarder is not required in detached utility buildings or other unheated facilities (2018 IBC 1907). MASONRY 1.Masonry materials, construction, and quality shall conform to 2018 IBC 2103-2105, TMS 402/602-16 1.1.Compressive strength: f'c = 2,000 psi (TMS 602-16 1.4B.2 TABLE 2) 2.Concrete masonry units (CMU) (ASTM C 90) 2.1.Grade N 2.2.Compressive strength: f'm = 2,000 psi (TMS 602-16 1.4B.2 TABLE 2) 3.Mortar (ASTM C 270) 3.1.Type S Portland cement (TMS 402-16 7.4.4.2.2) 3.2.Compressive strength: f'c = 2,000 psi (TMS 602-16 1.4B.2 TABLE 2) 4.Grout (ASTM C 476) 4.1.Type: fine or coarse (2018 IBC 2103.3) 4.2.Compressive strength (minimum specified at 28 days): f'c = 2,000 psi (ASTM C 1019) 5.Steel reinforcement 5.1.Deformed bars: fy = 60 ksi (ASTM A 615 Gr. 60) 5.2.Deformed Bar Anchors (DBA) (ASTM A1064) 5.3.Headed Stud Anchors (HSA) (ASTM A108) 6.Bed joint thickness shall be 5/8 inch maximum (TMS 602-16 1.4B.2) 7.Grout shall have an 8”-11” slump using a 3/8” maximum aggregate. Grout lifts shall not exceed 5 feet in height unless noted otherwise. Consolidate by mechanical vibration pours that exceed 12 inches in height. 8.The clear distance between parallel bars shall not be less than the nominal diameter of the bars, nor less than 1 inch (TMS 402-16 6.1.3). Joint reinforcement shall have cover not less than 5/8". (TMS 402-16 6.1.4.2) 9.The diameter of bend measured on the inside of reinforcing bars, other than for stirrups and ties, shall not be less than specified in table 6.1.8 (TMS 402-16 6.1.8.2) 10.All masonry below grade shall be solid grouted. 11.Control joint spacing not to exceed 30'-0". See Architectural for locations. MASONRY AND STONE VENEER 1.Masonry veneer materials, construction, and quality shall conform to 2018 IBC 2103-2105 and TMS 402-16 Chap. 6. 2.Lintels 2.1.Veneer shall not support any vertical load other than the dead load of the veneer above. Veneer above openings shall be supported on lintels of noncombustible materials. Lintels shall have 1 inch of bearing for each 1 foot of span, but not less than 4 inches of bearing. 3.Anchorage 3.1.Veneer shall be anchored to the supporting wall framing with hot-dipped galvanized metal ties. (Strand wire or corrugated sheet metal) 3.2.Engage all anchor ties with a No. 9 gage wire in the center of the veneer and embedded in the mortar joint. (R703.8.4.1) 3.3.Each tie shall be spaced not more than 16 inches on center horizontally and vertically and shall support not more than 2 square feet of wall area. Additional metal ties shall be provided around all wall openings greater than 16 inches in either dimension. (R703.8.4.1) WOOD 1.Wood materials, quality, and construction shall conform to 2018 IBC Chapter 23 and Table 2304.10. 2.Structural lumber (2018 IBC 2303.1.1-9, 2018 NDS) 2.1.Bearing walls: Douglas-Fir Larch (DF) Stud (ASTM D 1990, DOC PS 20) 2.2.Posts: Douglas-Fir Larch (DF) Stud (ASTM D 1990, DOC PS 20) 2.3.Beams and headers:Douglas-Fir Larch (DF) No. 2 (ASTM D 1990, DOC PS 20) 2.4.Heavy timber: Douglas-Fir Larch (DF) No. 1 (ASTM D 1990, DOC PS 20) 2.5.Sill plates: Preservative-treated wood, redwood (AWPA U1 M4) 2.6.Naturally durable or preservative-treated wood shall be used where structural lumber is 18 inches or closer to exposed ground; where structural lumber is in contact with exterior masonry or concrete walls below grade; where sleepers, sills, posts, and columns are on a concrete or masonry slab or footing that is in direct contact with earth; and where structural lumber is attached directly to exterior masonry or concrete walls, unless a 0.5 inch air space on top, sides, and end is provided (2018 IBC 2304.12). 3.Structural logs (ASTM D 3957) - ICC - 400 standard for the design and construction of log structures 4.Structural glued-laminated timber (2018 IBC 2303.1.3, 2018 NDS 5.1.1) 4.1.Single span: 24F-1.8E (24F-V4) (ASTM D 3737, ANSI/AITC A190.1) 4.2.Multiple span: 24F-1.8E Balanced layup (24F-V8) (ASTM D 3737, ANSI/AITC A190.1) 4.3.Cantilever span: 24F-1.8E Balanced layup (24F-V8) (ASTM D 3737, ANSI/AITC A190.1) 5.Structural composite lumber and engineered wood (2018 IBC 2303.1.10, 2018 NDS 8.1.1) 5.1.Laminated strand lumber (LSL) 5.1.1.Ex = 1.3E (ASTM D 5456) 5.1.2.Ex = 1.5E (ASTM D 5456) 5.1.3.Ex = 1.55E (ASTM D 5456) 5.1.4.1.125 inch APA Performance-Rated (or equivalent) rim board - (2018 IBC 2303.1.13, ASTM 7672, ANSI/APA PRR410) 5.2.Laminated veneer lumber (LVL) 5.2.1.Ex = 2.0E (ASTM D 5456) 5.3.Parallel strand lumber (PSL) 5.3.1.Ex = 2.0E (beams) (ASTM D 5456) 5.3.2.Ex = 1.8E (columns) (ASTM D 5456) 5.4.Prefabricated wood I-joist (2018 IBC 2303.1.2, 2018 NDS 7.1.1) (ASTM D 5055) 6.Wood structural panels (2018 IBC 2304.8, 2018 NDS 9.1.3) 6.1.Roof, floor, and wall sheathing: oriented strand board (OSB) (DOC PS 1,2). 6.2.Sheathing shall be manufactured with exterior glue and not less than 4X8 feet, except at boundaries and at changes in framing (2018 IBC 2305.1, AWC SDPWS-2015). 6.3.Wall sheathing 6.3.1.Oriented strand board (OSB) (DOC PS 1,2) 6.3.2.All panel joints in walls shall occur over studs or blocking using a minimum of 8d common nails spaced a maximum of 6 inches at panel edges and 12 inches at intermediate framing (2018 IBC 2306.3). 6.4.Roof and floor sheathing shall be placed perpendicular to supporting framing. Stagger sheathing joints. 7.Fasteners 7.1.Nails (2018 IBC 2303.6, 2018 NDS Table L4) (ASTM F 1667) Pennyweight Common Box Sinker 7.1.1.8d =0.131" X 2.5"0.113" X 2.5"0.113" X 2.375" 7.1.2.10d =0.148" X 3.0"0.128" X 3.0"0.120" X 2.875" 7.1.3.16d =0.162" X 3.5"0.135" X 3.5" 0.148" X 3.250" 7.1.4.20d =0.192" X 4.0"0.148" X 4.0"0.177" X 3.750" 7.1.5.30d =0.207" X 4.5"0.148" X 4.5"0.192" X 4.250" 7.2.Staples (2018 IBC 2303.6) 7.2.1.16 gage = 1.5X0.4375 inch crown (ASTM F 1667) 7.3.Bolts (2018 NDS 12.1.3, Table L1) 7.3.1.Connector bolts (A307) 7.3.2.Anchor bolts (A307) with a 3X3X0.229 inch washer (2018 IBC 2308.3.1) and 7" min embedment. 7.3.3.Bolt holes shall be drilled with a bit 1/32 inch to 1/16 inch larger than the nominal bolt diameter. 7.4.Lag Screws (2018 NDS 12.1.4, Table L2) (A307) 7.4.1.Lag screws shall be inserted in a drilled pilot hole that is 60%-75% of the shank diameter by turning with a wrench. Do not drive screws with a hammer. Lag screws shall be provided with an oversized washer . 7.5.Fasteners in preservative-treated and fire-retardant-treated wood shall be of hot dipped zinc-coated galvanized steel, silicon bronze or copper (2018 IBC 2304.10.5). 7.6.Sheathing fasteners shall be driven so the head or crown is flush with the sheathing surface (2018 IBC 2304.10.2). 8.Joist hangers and connectors (2018 IBC 2303.5) 8.1.Hanger hardware and other wood connections shall be designed to carry the capacity of the supporting members. 9.Floor framing (2018 IBC 2308.4.2) 9.1.Joists shall not have less than 1.5 inches of bearing on wood or metal, or less than 3 inches on masonry (2018 IBC 2308.4.2.2). Pre-fabricated wood I-joists shall have minimum bearing according to the manufacturer's recommendations and specifications. 9.2.Joists shall be supported laterally at the ends and at each support by full-depth solid blocking, except where nailed to a header or band or rim joist. Solid blocking shall not be less than 2 inches thick (2018 IBC 2308.4.2.3). 9.3.Where the nominal depth-to-thickness ratio of the framing member exceeds 6:1, there shall be one line of bridging for each 8 feet of span. Bridging shall consist of not less than 1X3 inch lumber, metal bracing, or full-depth solid blocking (2018 IBC 2308.4.6). 9.4.Notches on the ends of joists shall not exceed one-fourth the joist depth. Holes bored in joists shall not be within 2 inches of the top or bottom of the joist. Notches in the top or bottom of joists shall not exceed one-sixth the depth and shall not be located in the middle third of the span (2018 IBC 2308.4.2.4). 9.5.The diameter of holes bored or cut into structural floor members shall not exceed one-third the depth of the member. Holes shall not be closer than 2 inches to the top or bottom of the member, or to any other hole located in the member. Where the member is also notched, the hole shall not be closer than 2 inches to the notch (R502.8.1). 10.Wall construction (2018 IBC 2308.5) 10.1.Studs shall be placed with their wide dimension perpendicular to the wall. Not less than three studs shall be installed at each corner of an exterior wall (2018 IBC 2308.5.2). 10.2.Bearing and exterior wall studs shall be capped with 2-inch thick nominal double top plates, have a width at least equal to the width of the studs, and shall be installed to provide overlapping at corners and intersections with other partitions. End joints in partitions shall be offset at least 48 inches, and shall be nailed with not less than eight 16d common face nails on each side of the joint. (2018 IBC 2308.5.3.2). 10.3.In nonbearing walls and partitions studs shall be capped with no less than a single top plate installed to provide overlapping at corners and at intersections with other walls and partitions. The plate shall be continuously tied at joints by solid blocking at least 16 inches in length and equal in size to the plate or metal ties with spliced sections fastened on each side of the joint (2018 IBC 2308.5.4). 10.4.Studs shall have full bearing on a 2-inch thick nominal (or larger) bottom plate or sill having a width at least equal to the width of the stud (2018 IBC 2308.5.3.1). 10.5.Bearing partitions parallel to joists shall be supported on beams, girders, doubled joists, walls or other bearing partitions. Bearing partitions perpendicular to joists shall not be offset from supporting girders, walls or partitions more than the joist depth unless noted otherwise (2018 IBC 2308.4.5). 10.6.In exterior walls and bearing partitions, any wood stud is permitted to be cut or notched to a depth not exceeding 25 percent of its width. In nonbearing partitions, cutting or notching of studs to a depth of not greater than 40 percent of the width is permitted (2018 IBC 2308.5.9). 10.7.A hole with a diameter not greater than 40 percent of the stud width is permitted to be bored in any wood stud. In no case shall the edge of the bored hole be nearer than 0.625 inches to the edge of the stud. Bored holes shall not be located at the same section of stud as a cut or notch (2018 IBC 2308.5.10). 10.8.Bearing walls without wood sheathing or gypsum wall board on either side shall have blocking between wall studs at mid-height. 10.9.Studs shall be spaced at 16 inches on center for exterior walls, interior bearing walls, and shear walls, unless noted otherwise on the plans. 11.Posts and columns 11.1.Columns shall be as wide as the member they support, laterally supported at all floor levels, and extend down through the structure to the foundation. Provide squash blocking at rim joist below all columns, trimmers, and posts. 11.2.Wood columns and posts shall be framed to provide full end bearing (2018 IBC 2304.10.7). 11.3.Posts and columns shall be supported by concrete piers or metal pedestals projecting above concrete or masonry floors or decks exposed to weather or water splash, or in basements, and which support permanent structures, unless naturally durable or preservative-treated wood is used. The pedestal shall project at least 6 inches above exposed earth and at least 1 inch above floors. 12.Roof and ceiling framing (2018 IBC 2308.7). 12.1.Roof rafters and ceiling joists shall be supported laterally to prevent rotation and lateral displacement in accordance with 2018 IBC 2308.7.8. 12.2.Rafters and joists over three feet long shall be supported using hanger hardware if not supported by bearing. PREFABRICATED METAL PLATE WOOD TRUSSES 1.Prefabricated metal plate wood trusses shall be designed in accordance with 2018 IBC 2303.4 and shall conform to the structural specifications and design criteria. 2.The truss designer shall provide a truss package that includes the following items: 2.1.Design drawings of each individual truss (2018 IBC 2303.4.3). 2.2.Truss placement diagram for the project (2018 IBC 2303.4.2). 2.3.Truss member permanent bracing specification (2018 IBC 2303.4.1.2). 3.Transfer of loads and anchorage of each truss to the supporting structure shall be approved by the registered design professional in responsible charge (2018 IBC 2303.4.4). 4.Truss members and components shall not be cut, notched, drilled, spliced or otherwise altered in any way without written concurrence and approval of the registered design professional in responsible charge. Alterations resulting in the addition of loads to any member (e.g. HVAC equipment) shall not be permitted without verification that the truss is capable of supporting such additional loading (2018 IBC 2303.4.5). STEEL 1.Structural steel work shall conform to 2018 IBC 2205, AISC 341-16, AISC 358-16, and AISC 360-16. 2.Structural shapes 2.1.W: fy = 50 ksi (ASTM A992) 2.2.M,S,C,MC, and L: fy = 36 ksi (ASTM A36) 2.3.HP: fy = 50 ksi (ASTM A572 Gr. 50) 2.4.HSS Rectangular: fy = 46 ksi (ASTM A500 Gr.B) 2.5.HSS Round: fy = 42 ksi (ASTM A500 Gr.B) 2.6.Pipe: fy = 35 ksi (ASTM A53 Gr.B) 2.7.All structural steel shall be properly primed and painted. 3.Plates and bars: fy = 36 ksi (ASTM A36) 4.Structural fasteners 4.1.High-strength bolts: fu = 120-150 ksi (ASTM F3125) 4.2.Common bolts:fu = 60 ksi (ASTM A307 Gr. A) 4.2.1.Nuts (ASTM A563) 4.2.2.Washers (ASTM F436) 4.2.3.Steel to steel bolted connections shall be made with high strength-bolts, unless noted otherwise. Bolts shall carry the identifying mark of three radial lines. All other bolted connections shall be made with bolts and nuts conforming to ASTM A307 unless note otherwise. Bolted connections shall be tightened and shall have washers as required by AISC unless noted otherwise. Enlarging holes shall be accomplished by means of reaming. Do not use a torch on any bolt holes. 4.3.Shear studs: fu = 65 ksi (ASTM A108) 4.4.Threaded rods: fy = 36 ksi (ASTM A36) 4.5.Anchor rods: fy = 36 ksi (ASTM F1554 Gr. 36) 5.Steel deck fy = 36 ksi (ASTM A1008) 6.Welding fu = 70 ksi. 6.1.Welding work shall comply with the American Welding Society (AWS) “Structural Welding Code,” excluding items conflicting with AISC requirements. POST-INSTALLED ANCHORS 1.Epoxy adhesive anchoring systems: 1.1.Concrete: Hilti HIT-RE 500 V3 (ICC ES ESR-3814) or Simpson SET-XP (ICC ES ESR-2508) or USP/Mitek CIA-GEL 7000-C (IAMPO ER-473) 1.2.Masonry (grouted): Hilti HIT RE100 (ICC ES ESR-3829) or Simpson SET (ICC ES ESR-1772) or USP/Mitek CIA-GEL 7000 (ICC ES ESR-1702) 1.3.The calculated strength of anchorage assumes the following conditions for installation: 21 day minimum age of concrete, maximum short term concrete temperature= 150° F, maximum long term concrete temperature= 110° F, dry concrete surface, and normal weight concrete. See adhesive manufacturer notes for minimum temperature requirements. If conditions are otherwise, contact engineer for anchor specifications. 1.4.Steel reinforcement and rods shall be embedded 10 bar diameters unless noted otherwise in the structural drawings and details. Where 10 bar diameters exceeds the member thickness minus minimum cover, steel reinforcement shall be embedded the member thickness minus minimum cover with a standard hook. 1.5.Embedded portions of steel reinforcement and rods shall be clean, straight, and free of mill scale, rust and other coatings that impair the bond with the adhesive. Reinforcement must not be bent after installation (ICC ES ESR-3829). 1.6.Installation of adhesive anchors shall be performed by personnel trained to install adhesive anchors. 2.Mechanical expansion anchors: 2.1.Concrete: Hilti KWIK BOLT TZ (ICC ES ESR-1917) 2.2.Masonry: Hilti KWIK BOLT 3 (ICC ES ESR-1385) 2.3.Expansion anchors shall not be used in tensile load applications (e.g. hold-downs, moment frames). 3.Post-installed anchoring systems shall be installed according to the Manufacturer’s Printed Installation Instructions (MPII). Hole cleaning method shall be based on drilling method and borehole conditions and shall conform to the manufacturer’s instructions. STRUCTURAL OBSERVATIONS 1.Where required by the Provisions of Section 1704.6.1 or 1704.6.2, the owner shall employ a registered design professional to perform structural observations as defined in 2018 IBC 202. Prior to the commencement of observations, the structural observer shall submit to the building official a written statement identifying the frequency and extent of the structural observations. At the conclusion of the work, the structural observer shall submit to the building official a written statement that the site visits have been made and identify any reported deficiencies which have not been resolved (2018 IBC 1704.6). DESIGN CRITERIA Harris Architecture Madison Square Apartments (Rexburg) 1810720 1. Building code: Idaho Administrative Code (IDAPA) 07.03.01.004 1.1 Model building code: 2012 IBC 1.2 Use and occupancy classification: R-2 (Residential - permanent) 1.3 Risk Category: II (Not occupancy categories I, III, IV) 2. Dead loads 2.1 Roof = 15 psf (10 psf top chord, 5 psf bottom chord) 2.2 Floor = 20 psf 2.3 Walls = 10 psf (interior walls), 12 psf (exterior walls) 3. Live loads -- Roofs (ordinary construction) = 20 psf (or 300 lb point load) -- Residential (1-2 unit dwelling) = 40 psf -- Stairs and exits (residential 1-2 unit dwelling) = 40 psf (or 300 lb point load) -- Stairs and exits = 100 psf (or 300 lb point load) 4. Rain load 4.1 Median 15-minute duration rainfall intensity = in/hr 4.2 Median 60-minute duration rainfall intensity = in/hr 5. Snow load 5.1 Ground snow load, Pg = 50 psf (elevation 4865 ft) 5.2 Exposure factor, Ce = 1 5.3 Thermal factor, Ct = 1 5.4 Snow importance factor, Is = 1 5.5 Flat roof snow load, Pf = 35 psf 5.6 Roof slope factor, Cs = 1 6. Earthquake design data 6.1 Mapped acceleration parameters 6.1.1 Latitude, Longitude: 43.826, -111.794 6.1.2 MCE short period Ss = 0.37 SDS = 0.37 6.1.3 MCE 1.0 sec. period S1 = 0.14 SD1 = 0.22 6.2 Seismic design category: D 6.3 Seismic importance factor, Ie = 1 6.4 Basic structural system: Building frame systems 6.5 Seismic force-resisting system: Light-frame wood walls (wood sheathing) 6.5.1 Response modification factor R = 7 6.5.2 System overstrength factor Omega = 2.5 6.5.3 Deflection amplification factor Cd = 4.5 6.6 Equivalent Lateral Force Procedure 6.6.1 Seismic response coefficient Cs = 0.05 6.6.2 Seismic base shear (LRFD)V = 33946 lb 7. Wind design data 7.1 Exposure category: C 7.2 Basic design wind speed, V = 105 mph 7.3 Components and cladding pressure = 29 psf (end), 24 psf (interior) 7.4 Internal pressure coeff., Gcpi = 0.18 8. Geotechnical design basis: - Presumptive values, 2018 IBC Table 1806.2 8.2 Site class = D-Default 8.3 Soil notes: None 8.4 Lateral earth pressure 8.4.1 Active = 30 psf/ft 8.4.2 At-rest = 60 psf/ft 8.5 Allowable foundation parameters 8.5.1 Allowable soil bearing, Qa = 1500 psf 8.5.2 Allowable lateral bearing = 150 psf/ft 8.5.3 Coefficient of friction = 0.25 8.6 Minimum frost cover = 36 in. DEFERRED SUBMITTALS 1. The following items are to submitted subsequent to the time of application (deferred submittals): -- Prefabricated metal plate wood trusses - roof (truss manufacturer) -- Steel stairs (stair manufacturer) 2. Deferred submittals shall have the prior approval of the building official (2018 IBC 107.3.4.1). 3. Deferred submittal documents shall be submitted to the registered design professional in responsible charge who shall review and forward them to the building official with a notation indicating that the documents have been reviewed and found to be in general conformance to the design of the building (2018 IBC 107.3.4.1). 4. Deferred submittal items shall not be installed until the design and submittal documents have been approved by the building official (2018 IBC 107.3.4.1). 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS HA R R I S A R C H I T E C T U R E M A D I S O N S Q U A R E AP A R T M E N T S ( R E X B U R G ) -- - -- - -- -- 01 SEP 2020 1810720 KZG MCW - - - - - -- - GE N E R A L S T R U C T U R A L N O T E S NTS SN1 P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/20/2020 FW3 FW3 FT24 FW 3 FW 3 FW 1 0 FT 2 0 TY P . F O R A L L F O U N D A T I O N WA L L S ( U . N . O . ) TY P . F O R A L L F O O T I N G S B E L O W FO U N D A T I O N W A L L S ( U . N . O . ) FT28 FT28 FT22 FT22FT22 FT30 FT30 FT28 FT26 HITYP. FT26 FT28 FT28 FT28 FT22 FT22 FT22 FT28 FT26 FT28 FT26 FT28 FT26 FT26 FT26 SF36 FT18 SF36 FT18 FT 1 8 FT 1 8 FT18 FT18 SF42 SF30 FT18 SF36 SF36 FT20 FT 2 8 T FT 2 8 T SF36 FT18 SF36 FT18 FT 1 8 FT 1 8 FT18 FT18 SF42 SF30FT18 SF36 SF36 FT20 FT 2 8 T FT 2 8 T SF36 FT18 SF36 FT18 FT 1 8 FT 2 8 T FT 1 8 FT18 FT18 SF42 SF30FT18 SF36 SF36 FT20 FT 2 8 T FT 1 8 FT18 FT18 SF42 SF30 FT18 FT20FT 2 8 T FT 2 8 T SF36 SF36 V TYP. CW TYP. FW 3 FW 3 SF54 SF 5 4 SF54 SF 5 4 SF54 SF 5 4 SF54 SF 5 4 ZE 7"X9"X1/2" A36 STEEL BASE PLATE ZE 7"X10-1/2"X1/2" A36 STEEL BASE PLATE ZE 7"X10-1/2"X1/2" A36 STEEL BASE PLATE ZE 7"X9"X1/2" A36 STEEL BASE PLATE ZE 7"X10-1/2"X1/2" A36 STEEL BASE PLATE ZE 7"X10-1/2"X1/2" A36 STEEL BASE PLATE ZE 7"X9"X1/2" A36 STEEL BASE PLATE ZE 7"X10-1/2"X1/2" A36 STEEL BASE PLATE ZE 7"X10-1/2"X1/2" A36 STEEL BASE PLATE ZE 7"X9"X1/2" A36 STEEL BASE PLATE ZE 7"X10-1/2"X1/2" A36 STEEL BASE PLATE ZE 7"X10-1/2"X1/2" A36 STEEL BASE PLATE J J J J N N K K N N K K N N K K N N K K J J J J B B B B BBBB AA L L L A A LLL A A LLL AA L L L AA AA A A A A D FT 1 8 FT 1 8 SF 3 0 SF 3 0 SF 3 6 SF 3 6 SF 3 6 SF 3 6 FT26 E TYP. FW 3 FW3 FW 3 A AAAAA A A STYP. FOOTING SCHEDULE MARK WIDTH LENGTH THICKNESS REINFORCEMENT TRANSVERSE LENGTHWISE FT18 18 "CONT.10 "-(2) #4 FT20 20 "CONT.10 "-(2) #4 FT22 22 "CONT.10 "-(2) #4 FT26 26 "CONT.10 "-(3) #4 FT28 28 "CONT.10 "-(3) #4 FT30 30 "CONT.10 "-(3) #4 FT28T 28 "CONT.14 "#4 @ 7 "(4) #4 SF30 30 "30 "10 "(3) #4 (3) #4 SF36 36 "36 "12 "(4) #4 (4) #4 SF42 42 "42 "12 "(5) #4 (5) #4 SF54 54 "54 "12 "(6) #4 (6) #4 1. CONTINUOUS FOOTINGS SHALL BE CENTERED UNDER WALLS AND SPOT FOOTINGS SHALL BE CENTERED UNDER COLUMNS UNLESS NOTED OTHERWISE. 2. FOOTINGS AND FOUNDATIONS, EXCAVATIONS, GRADING, AND FILL SHALL COMPLY WITH THE PROVISIONS OF THE GEOTECHNICAL REPORT (SEE GSN) FOUNDATION WALL SCHEDULE MARK HEIGHT WIDTH REINFORCEMENT VERTICAL HORIZONTAL PLACEMENT FW3 3'8"#4 @ 18"(3) #4 CENTER FW10 10'8"#5 @ 10"(10) #4 CENTER 1. DOWEL VERTICAL BARS INTO FOOTING. 2. PLACE TOP AND BOTTOM BARS WITHIN 4" OF TOP AND BOTTOM OF WALL. 3. PLACE REINFORCEMENT IN CENTER OF WALL OR NEAR EACH FACE, AS NOTED. HOLD-DOWN SCHEDULE MARK HOLD-DOWN MINIMUM FASTENERS ANCHOR POST A LSTHD8 10d X 2-1/2" (.148 X 2-1/2")STRAP 8" EMBED.(2) 2X POST B STHD10 10d X 2-1/2" (.148 X 2-1/2")STRAP 10" EMBED.(2) 2X POST D CS16 (11" END LENGTHS) 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST E MST37 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST F MST48 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST J HDU2-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)5/8" A.B. 5" EMBED.(2) 2X POST K HDU4-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)5/8" A.B. 5" EMBED.(2) 2X POST L HDU5-SDS2.5 SDS1/4" X 2-1/2" (SDS25212) FOUNDATION WALL: SB5/8X24 FOOTING: 5/8" A.B. 7" EMBED. (2) 2X POST N HDU11-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)1" A.B. 9" EMBED.4 X 6 POST 1. HOLD-DOWNS SHALL BE SIMPSON STRONG-TIE OR EQUIVALENT. 2. SHEAR WALL EDGE NAILING SHALL BE TO HOLD-DOWN POST. 3. STHD STRAPS SHALL BE "RJ" TYPE AT RIM JOIST LOCATIONS. LLLL 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS HA R R I S A R C H I T E C T U R E M A D I S O N S Q U A R E AP A R T M E N T S ( R E X B U R G ) -- - -- - -- -- 01 SEP 2020 1810720 KZG MCW - - - - - -- - FO O T I N G A N D F O U N D A T I O N P L A N 3/16" = 1'-0" S0-0 FOOTING AND FOUNDATION PLAN 3/16" = 1'-0" P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/20/2020 CQTYP. GX TYP. SW 1 J J SW 1 J J SW 2 N N SW 1 K K SW 2 N N SW 1 K K SW 2 N N SW 1 K K SW 2 N N SW 1 K K SW 1 J J SW 1 J J GTTYP. BLTYP. 2X4 DF #2 @ 8" O.C. OR 2X6 DF STUD @ 12" O.C. 2X6 DF #2 @ 8" O.C.2X6 DF #2 @ 8" O.C. 2X4 DF #2 @ 8" O.C. OR 2X6 DF STUD @ 12" O.C. 2X6 DF #2 @ 8" O.C.2X6 DF #2 @ 8" O.C. 2x4 DF STUD @ 12" O.C. 2x4 DF STUD @ 12" O.C. 2x4 DF STUD @ 12" O.C. 2x4 DF STUD @ 12" O.C. 2x4 DF STUD @ 12" O.C. 2x4 DF STUD @ 12" O.C. HI TYP. SHEAR WALL SCHEDULE MARK SHEATHING EDGE NAILING ABUTTING PANEL EDGE FRAMING ANCHORAGE SOLE PLATE SILL PLATE SW1 7/16"8d @ 6"2X 10d @ 6"5/8" A.B. @ 32" SW2 7/16"8d @ 4"2X 10d @ 8"5/8" A.B. @ 32" SW3 7/16"8d @ 3"3X or (2)2X 10d @ 12"5/8" A.B. @ 32" 1. SHEATHING SHALL CONSIST OF WOOD STRUCTURAL PANELS (SEE GSN). 2. UNLESS NOTED ON DRAWINGS, EXTERIOR STUDS SHALL BE SPACED AT 16" O.C. 3. SHEATHING NAILS SHALL BE COMMON OR GALVANIZED BOX NAILS. - FIELD NAIL SPACING SHALL BE 12" FOR STUDS SPACED 16" O.C. OR LESS AND 6" O.C. FOR STUDS SPACED AT 24" O.C. 4. FOR SW1 ONLY, EDGE NAILS MAY BE SUBSTITUTED WITH 1-1/2" 16 GAGE STAPLES SPACED AT 3" O.C. AND FIELD NAILS MAY BE SUBSTITUTED WITH 16 GAGE STAPLES AT 12" O.C. 5. ANCHORAGE NAILS SHALL BE COMMON NAILS. 6. ANCHOR BOLTS SHALL HAVE A 3X3X0.229" WASHER AND 7" MIN EMBEDMENT. THE WASHER SHALL EXTEND TO WITHIN 1/2" FROM THE SHEATHING. 7. FOR SW3, SW4, SW7, AND SW8, (2) 2" NOMINAL FRAMING STITCH-NAILED TOGETHER WITH (2) 10d NAILS @ 6" MAY BE USED AT ABUTTING PANEL EDGES IN PLACE OF 3" NOMINAL FRAMING. HOLD-DOWN SCHEDULE MARK HOLD-DOWN MINIMUM FASTENERS ANCHOR POST A LSTHD8 10d X 2-1/2" (.148 X 2-1/2")STRAP 8" EMBED.(2) 2X POST B STHD10 10d X 2-1/2" (.148 X 2-1/2")STRAP 10" EMBED.(2) 2X POST D CS16 (11" END LENGTHS) 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST E MST37 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST F MST48 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST J HDU2-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)5/8" A.B. 5" EMBED.(2) 2X POST K HDU4-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)5/8" A.B. 5" EMBED.(2) 2X POST L HDU5-SDS2.5 SDS1/4" X 2-1/2" (SDS25212) FOUNDATION WALL: SB5/8X24 FOOTING: 5/8" A.B. 7" EMBED. (2) 2X POST N HDU11-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)1" A.B. 9" EMBED.4 X 6 POST 1. HOLD-DOWNS SHALL BE SIMPSON STRONG-TIE OR EQUIVALENT. 2. SHEAR WALL EDGE NAILING SHALL BE TO HOLD-DOWN POST. 3. STHD STRAPS SHALL BE "RJ" TYPE AT RIM JOIST LOCATIONS. 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS HA R R I S A R C H I T E C T U R E M A D I S O N S Q U A R E AP A R T M E N T S ( R E X B U R G ) -- - -- - -- -- 01 SEP 2020 1810720 KZG MCW - - - - - -- - BA S E M E N T S H E A R W A L L P L A N 3/16" = 1'-0" S0-1 BASEMENT SHEAR WALL PLAN 3/16" = 1'-0" P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/20/2020 CQTYP. F J 0 2 F J 0 2 FJ 01 FJ 01 FJ 01 ZA TYP. R TYP. MB 01 MB 01 (FLUSH) (FLUSH) MB 0 2 (F L U S H ) BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALLBEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL P 0 4 MB 03 (FLUSH) MB 04 P 06 MB 05 MB 0 6 (F L U S H ) (DROPPED) MB 07 (FLUSH) ITS1.81/11.88 HANGER OR EQUIVALENT MB 01 MB 01 (FLUSH) (FLUSH) MB 0 2 (F L U S H ) P 0 4 MB 03 (FLUSH) MB 04 P 0 6 MB 05 MB 0 6 (F L U S H ) (DROPPED) ITS1.81/11.88 HANGER OR EQUIVALENT MB 07 (FLUSH) MB 01 MB 01 (FLUSH) (FLUSH) MB 0 2 (F L U S H ) P 0 4 MB 03 (FLUSH) MB 04 P 0 6 MB 05 MB 0 6 (F L U S H ) (DROPPED) MB 07 (FLUSH) ITS1.81/11.88 HANGER OR EQUIVALENT MB 08 (FLUSH)MB 09 MB 1 0 MB 11 P 03 P 0 3 MB 12 (FLUSH) MB 13 MB 08 (FLUSH)MB 09 MB 1 0 MB 11 P 0 3 P 03 MB 12 (FLUSH) MB 13 MB 08 (FLUSH)MB 09 MB 1 0 MB 11 P 0 3 P 03 MB 12 (FLUSH) MB 13 MB 08 (FLUSH)MB 09 MB 1 0 MB 11 P 0 3 P 0 3 MB 12 (FLUSH) MB 13 IA TYP. GU TYP. FJ 0 2 P 0 4 P 0 4 (DROPPED)(DROPPED)(DROPPED)(DROPPED) MB 14 MB 14 MB 14 MB 15 MB 15 MB 15 MB 15 MB 15 MB 15 MB 15 MB 15 P 04 MB 14 MB 14MB 14 MB 14 MB 14MB 14 MB 14 SHEATHING SCHEDULE TYPE THICKNESS FLOOR 3/4" OSB (48/24 SPAN RATING) ROOF 7/16" OSB (24/16 SPAN RATING) 1. SHEATHING PERPENDICULAR TO SUPPORTS. 2. FLOOR SHEATHING NAILED & GLUED TO SUPPORT 3. 8d COMMON NAILS 6" O.C. (EDGES) 12" O.C. (FIELD) 4. NAILING NO CLOSER THAN 3/8" FROM PANEL EDGE FLOOR JOIST SCHEDULE MARK TYPE FJ 01 11-7/8" TJI 210 @ 16" O.C. FJ 02 11-7/8" TJI 210 @ 12" O.C. 1. DIMENSIONAL LUMBER DF #2 U.N.O. 2. SUFFIXES (A, B, ETC.) DENOTE ALTERNATIVES FOR THE SPECIFIED JOIST POST SCHEDULE MARK TYPE P 03 (3) 2X POST P 04 (4) 2X POST P 06 4 X 6 POST P 16 W10X26 P 17 W8X18 T 02 (2) TRIM 1. PARALLEL STRAND LUMBER (PSL) 1.8E 2. STEEL PIPE (PIPE STD) A53 3. STEEL HOLLOW SECTION (HSS) A500 4. STEEL COLUMNS REQUIRE BEARING PLATES 5. CONTINUE POSTS TO FDN / STRUCT MEMBER BEAM SCHEDULE MARK TYPE MB 01 1-3/4 X 11-7/8 LVL MB 02 1-3/4 X 11-7/8 LVL MB 03 (2) 1-3/4 X 11-7/8 LVL MB 04 (2) 2 X 6 MB 05 (2) 1-3/4 X 9-1/2 LVL MB 06 1-3/4 X 11-7/8 LVL MB 07 1-3/4 X 11-7/8 LVL MB 08 1-3/4 X 11-7/8 LVL MB 09 (2) 1-3/4 X 9-1/2 LVL MB 10 (2) 2 X 6 MB 11 (2) 2 X 6 MB 12 (2) 1-3/4 X 11-7/8 LVL MB 13 (2) 2 X 6 MB 14 (3) 2 X 6 MB 15 (2) 2 X 6 1. DIMENSIONAL LUMBER DF #2 U.N.O. 2. LAMINATED VENEER LUMBER (LVL) 2.0E 3. GLUED-LAMINATED TIMBER (GLB) 24F-1.8E 4. STEEL W-SHAPES A992-50 5. SUFFIXES (A, B, ETC.) DENOTE ALTERNATIVES FOR THE SPECIFIED BEAM 6. ALL HEADERS IN BEARING WALLS TO HAVE MIN. (1) TRIMMER & (1) KING STUD U.N.O. ALL OTHER BEAMS AND GIRDER TRUSSES TO HAVE MIN. (2) 2X SUPPORTS U.N.O. 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS HA R R I S A R C H I T E C T U R E M A D I S O N S Q U A R E AP A R T M E N T S ( R E X B U R G ) -- - -- - -- -- 01 SEP 2020 1810720 KZG MCW - - - - - -- - MA I N F L O O R F R A M I N G P L A N 3/16" = 1'-0" S1-0 MAIN FLOOR FRAMING PLAN 3/16" = 1'-0" P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/20/2020 CQTYP. SW1 A A SW 1 D D SW2 B B SW2 B B NO H O L D - D O W N S R E Q U I R E D SW 1 SW2 AA SW1 AA SW 1 D D SW2 BB SW2 BB SW 1 B F SW 1 E E NO HOLD-DOWNS REQUIRED SW1 FH SW3 L L SW2 L L SW 1 B F SW 1 D D NO HOLD-DOWNS REQUIRED SW1 FH SW3 LL SW2 LL SW 1 B F SW 1 D D NO HOLD-DOWNS REQUIRED SW1 FH SW3 LL SW2 LL SW 1 B F SW 1 E E NO HOLD-DOWNS REQUIRED SW1 FH SW3 L L SW2 L L SW1 AA SW1 AA GX TYP. SW2 B B SW2 B B SW 1 D D SW 1 D D GTTYP. ADTYP. BSTYP.BLTYP. HTYP. SW1 A A NO H O L D - D O W N S R E Q U I R E D SW 1 SHEAR WALL SCHEDULE MARK SHEATHING EDGE NAILING ABUTTING PANEL EDGE FRAMING ANCHORAGE SOLE PLATE SILL PLATE SW1 7/16"8d @ 6"2X 10d @ 6"5/8" A.B. @ 32" SW2 7/16"8d @ 4"2X 10d @ 8"5/8" A.B. @ 32" SW3 7/16"8d @ 3"3X or (2)2X 10d @ 12"5/8" A.B. @ 32" 1. SHEATHING SHALL CONSIST OF WOOD STRUCTURAL PANELS (SEE GSN). 2. UNLESS NOTED ON DRAWINGS, EXTERIOR STUDS SHALL BE SPACED AT 16" O.C. 3. SHEATHING NAILS SHALL BE COMMON OR GALVANIZED BOX NAILS. - FIELD NAIL SPACING SHALL BE 12" FOR STUDS SPACED 16" O.C. OR LESS AND 6" O.C. FOR STUDS SPACED AT 24" O.C. 4. FOR SW1 ONLY, EDGE NAILS MAY BE SUBSTITUTED WITH 1-1/2" 16 GAGE STAPLES SPACED AT 3" O.C. AND FIELD NAILS MAY BE SUBSTITUTED WITH 16 GAGE STAPLES AT 12" O.C. 5. ANCHORAGE NAILS SHALL BE COMMON NAILS. 6. ANCHOR BOLTS SHALL HAVE A 3X3X0.229" WASHER AND 7" MIN EMBEDMENT. THE WASHER SHALL EXTEND TO WITHIN 1/2" FROM THE SHEATHING. 7. FOR SW3, SW4, SW7, AND SW8, (2) 2" NOMINAL FRAMING STITCH-NAILED TOGETHER WITH (2) 10d NAILS @ 6" MAY BE USED AT ABUTTING PANEL EDGES IN PLACE OF 3" NOMINAL FRAMING. HOLD-DOWN SCHEDULE MARK HOLD-DOWN MINIMUM FASTENERS ANCHOR POST A LSTHD8 10d X 2-1/2" (.148 X 2-1/2")STRAP 8" EMBED.(2) 2X POST B STHD10 10d X 2-1/2" (.148 X 2-1/2")STRAP 10" EMBED.(2) 2X POST D CS16 (11" END LENGTHS) 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST E MST37 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST F MST48 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST J HDU2-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)5/8" A.B. 5" EMBED.(2) 2X POST K HDU4-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)5/8" A.B. 5" EMBED.(2) 2X POST L HDU5-SDS2.5 SDS1/4" X 2-1/2" (SDS25212) FOUNDATION WALL: SB5/8X24 FOOTING: 5/8" A.B. 7" EMBED. (2) 2X POST N HDU11-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)1" A.B. 9" EMBED.4 X 6 POST 1. HOLD-DOWNS SHALL BE SIMPSON STRONG-TIE OR EQUIVALENT. 2. SHEAR WALL EDGE NAILING SHALL BE TO HOLD-DOWN POST. 3. STHD STRAPS SHALL BE "RJ" TYPE AT RIM JOIST LOCATIONS. 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS HA R R I S A R C H I T E C T U R E M A D I S O N S Q U A R E AP A R T M E N T S ( R E X B U R G ) -- - -- - -- -- 01 SEP 2020 1810720 KZG MCW - - - - - -- - MA I N F L O O R S H E A R W A L L P L A N 3/16" = 1'-0" S1-1 MAIN FLOOR SHEAR WALL PLAN 3/16" = 1'-0" P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/20/2020 BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALL BEARING WALLBEARING WALLBEARING WALLBEARING WALL CQTYP. DO U B L E R A F T E R DO U B L E R A F T E R DO U B L E R A F T E R DO U B L E R A F T E R DO U B L E R A F T E R DO U B L E R A F T E R FJ 0 2 FJ 02 FJ 02 F J 0 2 F J 0 1 FJ 01 FJ 01 FJ 01 FJ 01 FJ 0 1 FJ 0 1 FJ 0 1 FJ 0 1 FJ 0 1 FJ 01 R TYP. PTYP. UB 29 UB 10 (FLUSH)P 0 3 P 0 3 UB 01 UB 01 IY USE (2) ROWS SDW22500 SCREWS @ 16" O.C. UB 02 (FLUSH) UB 03 UB 0 4 UB 0 5 UB 06 UB 09 UB 09 UB 11 T 0 2 UB 12 P 0 3 IYUSE (2) ROWS SDW22500 SCREWS @ 16" O.C. UB 02 (FLUSH) UB 03 UB 0 4 UB 0 5 UB 10 UB 09UB 09 UB 11 T 02 (FLUSH) UB 12 P 03 UB 01 UB 01 IY USE (2) ROWS SDW22500 SCREWS @ 16" O.C. UB 02 (FLUSH) UB 03 UB 0 4 UB 0 5 UB 06 UB 09 UB 09 UB 11 T 0 2 UB 12 P 0 3 IYUSE (2) ROWS SDW22500 SCREWS @ 16" O.C. UB 02 (FLUSH) UB 03 UB 0 4 UB 0 5 UB 10 UB 09 UB 09 UB 11 T 02 (FLUSH) UB 12 P 0 3 CU2X6 LEDGER W/ (2) ROWS 16d NAILS @ 16" O.C. CU 2X6 LEDGER W/ (2) ROWS 16d NAILS @ 16" O.C. CU 2X6 LEDGER W/ (2) ROWS 16d NAILS @ 16" O.C. RB 1 8 RB 20 RB 19 STRAP DOUBLE RAFTER TO SUPPORT WITH (1) 24" LONG CS16 STRAP UPSIDE DOWN LUS26-2 HANGER OR EQUIVALENT RB 1 8 RB 20 RB 19 STRAP DOUBLE RAFTER TO SUPPORT WITH (1) 24" LONG CS16 STRAP UPSIDE DOWN LUS26-2 HANGER OR EQUIVALENT RB 1 8 RB 20 RB 19 STRAP DOUBLE RAFTER TO SUPPORT WITH (1) 24" LONG CS16 STRAP UPSIDE DOWN LUS26-2 HANGER OR EQUIVALENT (FLUSH) T 02 T 0 2 T 0 2 T 0 2 T 0 2 T 0 2 T 02 T 0 2 P 03 P 0 3 P 06 UB 13 (FLUSH) UB 29 (FLUSH)P 0 6 UB 13 (FLUSH) UB 29 (FLUSH) P 0 6 UB 13 (FLUSH) UB 29 (FLUSH)P 06 UB 13 (FLUSH) PROVIDE 1.5" BEARING FOR UB13 P 0 3 P 0 3 P 0 3 P 0 3 PROVIDE 1.5" BEARING FOR UB13 PROVIDE 1.5" BEARING FOR UB13 PROVIDE 1.5" BEARING FOR UB13 UB 14 UB 15 UB 1 6 (FLUSH) (F L U S H ) UB 17 UB 14 UB 15 UB 1 6 (FLUSH) (F L U S H ) UB 18 UB 15 UB 1 6 (FLUSH) (F L U S H ) UB 17 P 0 4 UB 19 QO UB 2 0 UB 21 QO P 0 4 UB 19 QO UB 2 0 UB 21 QO P 0 3 P 0 4 UB 19 QO UB 2 0 UB 21 QO P 0 3 UB 23 UB 24UB 23 UB 23UB 24UB 25 UB 26 UB 27 IA TYP.AP TYP. GU TYP. UB 07 UB 28 UB 07 UB 28 P 0 3 P 0 3 P 0 3 P 0 3 P 0 3 P 0 3 ZBZB ZC ZC ZCZC ZCZC ZG ZG ZG ZG STEEL STAIRS BY OTHERS STEEL STAIRS BY OTHERS ZD ZD ZD ZD ZD ZD ZD ZD ZD ZD ZD ZD R R 0 1 RR 0 1 RR 0 1 UB 10 (FLUSH) UB 2 2 (F L U S H ) RB 23 RB 2 2 (BELOW) (B E L O W ) (BE L O W ) DROPPED BELOW STAIR LANDING DROPPED BELOW STAIR LANDING (BELOW) (B E L O W ) (BE L O W ) DROPPED BELOW STAIR LANDING DROPPED BELOW STAIR LANDING IE IE IEIE IE IE IEIEP 03 (BELOW) P 0 3 ( B E L O W ) P 0 3 P 0 3 P 0 3 P 0 3 P 0 3 IY (2) ROWS SDW22500 SCREWS @ 16" O.C. IY (2) ROWS SDW22500 SCREWS @ 16" O.C. IY (2) ROWS SDW22500 SCREWS @ 16" O.C. IY (2) ROWS SDW22500 SCREWS @ 16" O.C. LF LF QTYP. XH TYP. P 1 7 P 1 7 P 1 7 P 1 7 P 1 6 P 16 P 1 6 P 1 6 P 1 6 P 16 P 1 6 P 1 6 BEAM SCHEDULE MARK TYPE UB 01 (2) 2 X 6 UB 02 (3) 1-3/4 X 11-7/8 LVL UB 03 (3) 2 X 6 UB 04 W10X26 UB 05 W10X26 UB 06 W10X26 UB 07 W10X26 UB 08 (3) 2 X 6 UB 09 (2) 2 X 6 UB 10 (2) 1-3/4 X 11-7/8 LVL UB 11 (3) 2 X 6 UB 12 (3) 2 X 6 UB 13 (3) 1-3/4 X 11-7/8 LVL UB 14 (3) 2 X 8 UB 15 1-3/4 X 11-7/8 LVL UB 16 1-3/4 X 11-7/8 LVL UB 17 (2) 2 X 6 UB 18 (2) 2 X 6 UB 19 (2) 1-3/4 X 11-7/8 LVL UB 20 (2) 2 X 6 UB 21 (2) 1-3/4 X 11-7/8 LVL UB 22 (2) 1-3/4 X 11-7/8 LVL UB 23 (3) 2 X 6 UB 24 (3) 2 X 8 UB 25 (3) 2 X 8 UB 26 (3) 2 X 8 UB 27 (2) 2 X 6 UB 28 W10X26 UB 29 (2) 1-3/4 X 11-7/8 LVL 1. DIMENSIONAL LUMBER DF #2 U.N.O. 2. LAMINATED VENEER LUMBER (LVL) 2.0E 3. GLUED-LAMINATED TIMBER (GLB) 24F-1.8E 4. STEEL W-SHAPES A992-50 5. SUFFIXES (A, B, ETC.) DENOTE ALTERNATIVES FOR THE SPECIFIED BEAM 6. ALL HEADERS IN BEARING WALLS TO HAVE MIN. (1) TRIMMER & (1) KING STUD U.N.O. ALL OTHER BEAMS AND GIRDER TRUSSES TO HAVE MIN. (2) 2X SUPPORTS U.N.O. PRE- M A N U F A C T U R E D R O O F T R U S S E S @ 2 4 " O . C . W PR E - M A N U F A C T U R E D T R U S S E S @ 2 4 " O . C . SHEATHING SCHEDULE TYPE THICKNESS FLOOR 3/4" OSB (48/24 SPAN RATING) ROOF 7/16" OSB (24/16 SPAN RATING) 1. SHEATHING PERPENDICULAR TO SUPPORTS. 2. FLOOR SHEATHING NAILED & GLUED TO SUPPORT 3. 8d COMMON NAILS 6" O.C. (EDGES) 12" O.C. (FIELD) 4. NAILING NO CLOSER THAN 3/8" FROM PANEL EDGE FLOOR JOIST SCHEDULE MARK TYPE FJ 01 11-7/8" TJI 210 @ 16" O.C. FJ 02 11-7/8" TJI 210 @ 12" O.C. 1. DIMENSIONAL LUMBER DF #2 U.N.O. 2. SUFFIXES (A, B, ETC.) DENOTE ALTERNATIVES FOR THE SPECIFIED JOIST POST SCHEDULE MARK TYPE P 03 (3) 2X POST P 04 (4) 2X POST P 06 4 X 6 POST P 16 W10X26 P 17 W8X18 T 02 (2) TRIM 1. PARALLEL STRAND LUMBER (PSL) 1.8E 2. STEEL PIPE (PIPE STD) A53 3. STEEL HOLLOW SECTION (HSS) A500 4. STEEL COLUMNS REQUIRE BEARING PLATES 5. CONTINUE POSTS TO FDN / STRUCT MEMBER WOOD TRUSS LOADS GROUND SNOW LOAD, Pg = 50 PSF FLAT ROOF SNOW LOAD = 35 PSF TOP CHORD DEAD LOAD = 10 PSF BOTTOM CHORD DEAD LOAD = 5 PSF 1. DESIGN SNOW LOADS SHALL BE IN ACCORDANCE WITH ASCE 7-16 CHAP.7 (2018 IBC 1608.1) ROOF RAFTER SCHEDULE MARK TYPE RR 01 2 X 6 @ 24" O.C. RR 02 2 X 10 @ 24" O.C. 1. DIMENSIONAL LUMBER DF #2 U.N.O. 2. SUFFIXES (A, B, ETC.) DENOTE ALTERNATIVES FOR THE SPECIFIED RAFTER BEAM SCHEDULE MARK TYPE RB 01 (2) 2 X 6 RB 02 (3) 1-3/4 X 9-1/2 LVL RB 03 (3) 2 X 6 RB 04 (2) 2 X 8 RB 05 W10X26 RB 06 (2) 2 X 6 RB 07 (3) 2 X 6 RB 08 W10X26 RB 09 (2) 2 X 6 RB 10 (3) 2 X 10 RB 11 (2) 2 X 6 RB 12 (3) 2 X 6 RB 13 (3) 2 X 6 RB 14 (2) 2 X 6 RB 15 (2) 2 X 6 RB 16 (2) 2 X 6 RB 17 (3) 2 X 8 RB 18 (2) 2 X 6 RB 19 (2) 2 X 6 RB 20 (2) 2 X 6 RB 21 (3) 2 X 6 RB 22 (2) 2 X 6 RB 23 (2) 2 X 6 1. DIMENSIONAL LUMBER DF #2 U.N.O. 2. LAMINATED VENEER LUMBER (LVL) 2.0E 3. GLUED-LAMINATED TIMBER (GLB) 24F-1.8E 4. STEEL W-SHAPES A992-50 5. SUFFIXES (A, B, ETC.) DENOTE ALTERNATIVES FOR THE SPECIFIED BEAM 6. ALL HEADERS IN BEARING WALLS TO HAVE MIN. (1) TRIMMER & (1) KING STUD U.N.O. ALL OTHER BEAMS AND GIRDER TRUSSES TO HAVE MIN. (2) 2X SUPPORTS U.N.O. 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS HA R R I S A R C H I T E C T U R E M A D I S O N S Q U A R E AP A R T M E N T S ( R E X B U R G ) -- - -- - -- -- 01 SEP 2020 1810720 KZG MCW - - - - - -- - SE C O N D F L O O R F R A M I N G P L A N 3/16" = 1'-0" S2-0 SECOND FLOOR FRAMING PLAN 3/16" = 1'-0" P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/20/2020 NO H O L D - D O W N S R E Q U I R E D SW 1 NO H O L D - D O W N S R E Q U I R E D SW 1 NO H O L D - D O W N S R E Q U I R E D SW 1 NO H O L D - D O W N S R E Q U I R E D SW 1 NO HOLD-DOWNS REQUIRED SW1 Y NO HOLD-DOWNS REQUIRED SW1 Y SW 1 D D SW 1 D D SW 1 D D SW 1 D D NO HOLD-DOWNS REQUIRED SW1 FH SW1 D D SW1 D D SW2 F F SW2 F F SW2 F F SW2 F F SW1 D D SW1 D D SW 1 D D SW 1 D D NO HOLD-DOWNS REQUIRED SW1 FH NO HOLD-DOWNS REQUIRED SW1 Y SW1 DD SW1 DD SW 1 D D SW 1 D D NO HOLD-DOWNS REQUIRED SW1 FH SW2 FF SW2 FF SW2 FF SW2 FF SW 1 D D SW 1 D D NO HOLD-DOWNS REQUIRED SW1 FH HTYP. GTTYP. CQTYP. GX TYP. EM EM EM EM ALIGN HOLD-DOWN WITH WALL BELOW ALIGN HOLD-DOWN WITH WALL BELOW ALIGN HOLD-DOWN WITH WALL BELOW ALIGN HOLD-DOWN WITH WALL BELOWCT CI SHEAR WALL SCHEDULE MARK SHEATHING EDGE NAILING ABUTTING PANEL EDGE FRAMING ANCHORAGE SOLE PLATE SILL PLATE SW1 7/16"8d @ 6"2X 10d @ 6"5/8" A.B. @ 32" SW2 7/16"8d @ 4"2X 10d @ 8"5/8" A.B. @ 32" SW3 7/16"8d @ 3"3X or (2)2X 10d @ 12"5/8" A.B. @ 32" 1. SHEATHING SHALL CONSIST OF WOOD STRUCTURAL PANELS (SEE GSN). 2. UNLESS NOTED ON DRAWINGS, EXTERIOR STUDS SHALL BE SPACED AT 16" O.C. 3. SHEATHING NAILS SHALL BE COMMON OR GALVANIZED BOX NAILS. - FIELD NAIL SPACING SHALL BE 12" FOR STUDS SPACED 16" O.C. OR LESS AND 6" O.C. FOR STUDS SPACED AT 24" O.C. 4. FOR SW1 ONLY, EDGE NAILS MAY BE SUBSTITUTED WITH 1-1/2" 16 GAGE STAPLES SPACED AT 3" O.C. AND FIELD NAILS MAY BE SUBSTITUTED WITH 16 GAGE STAPLES AT 12" O.C. 5. ANCHORAGE NAILS SHALL BE COMMON NAILS. 6. ANCHOR BOLTS SHALL HAVE A 3X3X0.229" WASHER AND 7" MIN EMBEDMENT. THE WASHER SHALL EXTEND TO WITHIN 1/2" FROM THE SHEATHING. 7. FOR SW3, SW4, SW7, AND SW8, (2) 2" NOMINAL FRAMING STITCH-NAILED TOGETHER WITH (2) 10d NAILS @ 6" MAY BE USED AT ABUTTING PANEL EDGES IN PLACE OF 3" NOMINAL FRAMING. HOLD-DOWN SCHEDULE MARK HOLD-DOWN MINIMUM FASTENERS ANCHOR POST A LSTHD8 10d X 2-1/2" (.148 X 2-1/2")STRAP 8" EMBED.(2) 2X POST B STHD10 10d X 2-1/2" (.148 X 2-1/2")STRAP 10" EMBED.(2) 2X POST D CS16 (11" END LENGTHS) 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST E MST37 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST F MST48 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST J HDU2-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)5/8" A.B. 5" EMBED.(2) 2X POST K HDU4-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)5/8" A.B. 5" EMBED.(2) 2X POST L HDU5-SDS2.5 SDS1/4" X 2-1/2" (SDS25212) FOUNDATION WALL: SB5/8X24 FOOTING: 5/8" A.B. 7" EMBED. (2) 2X POST N HDU11-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)1" A.B. 9" EMBED.4 X 6 POST 1. HOLD-DOWNS SHALL BE SIMPSON STRONG-TIE OR EQUIVALENT. 2. SHEAR WALL EDGE NAILING SHALL BE TO HOLD-DOWN POST. 3. STHD STRAPS SHALL BE "RJ" TYPE AT RIM JOIST LOCATIONS. 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS HA R R I S A R C H I T E C T U R E M A D I S O N S Q U A R E AP A R T M E N T S ( R E X B U R G ) -- - -- - -- -- 01 SEP 2020 1810720 KZG MCW - - - - - -- - SE C O N D F L O O R S H E A R W A L L P L A N 3/16" = 1'-0" S2-1 SECOND FLOOR SHEAR WALL PLAN 3/16" = 1'-0" P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/20/2020 GIRDER TRUSS GIRDER TRUSS GIRDER TRUSS GIRDER TRUSS GIRDER TRUSS GIRDER TRUSSGIRDER TRUSS BEARING WALL BEARING WALLBEARING WALL CQTYP. BEARING WALL FJ 02 FJ 0 2 FJ 0 1 FJ 01 P R E - M A N U F A C T U R E D R O O F T R U S S E S @ 2 4 " O . C . PR E - M A N U F A C T U R E D R O O F T R U S S E S @ 2 4 " O . C . P R E - M A N U F A C T U R E D R O O F T R U S S E S @ 2 4 " O . C . R TYP. P TYP. RR 01 RR 0 1 RR 0 1 FJ 01 FJ 01 FJ 01 FJ 01 RB 11 RB 11 RB 1 2 RB 1 2 RB 1 3 RB 14 HANG RB13 FROM GIRDER TRUSS WITH UPSIDE DOWN HUC26-3 (MAX 10d NAILING) HANGER OR EQUIVALENT. DESIGN FOR POINT LOAD: SNOW: 55# DEAD: -350# (MAX UPLIFT: 1340#) HANG RB12 FROM GIRDER TRUSS WITH UPSIDE DOWN HUC26-3 (MAX 16d NAILING) HANGER OR EQUIVALENT. DESIGN FOR POINT LOAD: SNOW: 55# DEAD: -350# (MAX UPLIFT: 1730#) HUC26-2 HANGER OR EQUIVALENT HANG RB12 FROM GIRDER TRUSS WITH UPSIDE DOWN HUC26-3 (MAX 16d NAILING) HANGER OR EQUIVALENT. DESIGN FOR POINT LOAD: SNOW: 55# DEAD: -350# (MAX UPLIFT: 1730#) UPSIDE DOWN HUC26-3 HANGER OR EQUIVALENT UPSIDE DOWN HUC26-3 HANGER OR EQUIVALENT RB 15 RB 11RB 11 RB 1 2 RB 1 2 RB 1 3 RB 14 HANG RB12 FROM GIRDER TRUSS WITH UPSIDE DOWN HUC26-3 (MAX 16d NAILING) HANGER OR EQUIVALENT. DESIGN FOR POINT LOAD: SNOW: 55# DEAD: -350# (MAX UPLIFT: 1730#) HUC26-2 HANGER OR EQUIVALENT HANG RB12 FROM GIRDER TRUSS WITH UPSIDE DOWN HUC26-3 (MAX 16d NAILING) HANGER OR EQUIVALENT. DESIGN FOR POINT LOAD: SNOW: 55# DEAD: -350# (MAX UPLIFT: 1730#) UPSIDE DOWN HUC26-3 HANGER OR EQUIVALENT UPSIDE DOWN HUC26-3 HANGER OR EQUIVALENT RB 21 RB 11 RB 1 2 RB 1 2 RB 14 HANG RB13 FROM GIRDER TRUSS WITH UPSIDE DOWN HUC26-3 (MAX 10d NAILING) HANGER OR EQUIVALENT. DESIGN FOR POINT LOAD: SNOW: 55# DEAD: -350# (MAX UPLIFT: 1340#) HANG RB12 FROM GIRDER TRUSS WITH UPSIDE DOWN HUC26-3 (MAX 16d NAILING) HANGER OR EQUIVALENT. DESIGN FOR POINT LOAD: SNOW: 55# DEAD: -350# (MAX UPLIFT: 1730#) HANG RB12 FROM GIRDER TRUSS WITH UPSIDE DOWN HUC26-3 (MAX 16d NAILING) HANGER OR EQUIVALENT. DESIGN FOR POINT LOAD: SNOW: 55# DEAD: -350# (MAX UPLIFT: 1730#) UPSIDE DOWN HUC26-3 HANGER OR EQUIVALENT UPSIDE DOWN HUC26-3 HANGER OR EQUIVALENT RB 15 HUC26-2 HANGER OR EQUIVALENT RB 16 RB 16 RB 16 RB 16RB 17 RB 17 Q TYP. GU TYP. AP TYP.IA TYP. F TYP. UB 01 UB 01 IY USE (2) ROWS SDW22500 SCREWS @ 16" O.C. UB 02 (FLUSH) UB 03 UB 0 4 UB 0 5 UB 06 UB 08 (DROPPED) UB 10UB 09 UB 09 BEARING WALL UB 11 T 0 2 (FLUSH) UB 12 IYUSE (2) ROWS SDW22500 SCREWS @ 16" O.C. UB 02 (FLUSH) UB 03 UB 0 4 UB 0 5 UB 08 (DROPPED) UB 10 UB 09UB 09 UB 11 T 02 (FLUSH) UB 12 BEARING WALL UB 01UB 01 IYUSE (2) ROWS SDW22500 SCREWS @ 16" O.C. UB 02 (FLUSH) UB 03 UB 0 4 UB 0 5 UB 06 UB 08 (DROPPED) UB 10 UB 09UB 09 BEARING WALL UB 11 T 02 (FLUSH) UB 12 P 04 IY USE (2) ROWS SDW22500 SCREWS @ 16" O.C. UB 02 (FLUSH) UB 03 UB 0 4 UB 0 5 UB 08 (DROPPED) UB 10UB 09 UB 09 UB 11 T 0 2 (FLUSH) UB 12 P 0 4 BEARING WALL HANG RB13 FROM GIRDER TRUSS WITH UPSIDE DOWN HUC26-3 (MAX 10d NAILING) HANGER OR EQUIVALENT. DESIGN FOR POINT LOAD: SNOW: 55# DEAD: -350# (MAX UPLIFT: 1340#) UB 07 UB 28 UB 07 UB 28 P 0 3 P 0 3 P 0 3 P 0 3 P 0 3 P 0 3 ZBZB ZC ZC ZCZC ZC ZC ZG ZG ZG ZG STEEL STAIRS BY OTHERS STEEL STAIRS BY OTHERS ZD ZD ZD ZD ZD ZD ZD ZD ZD ZD ZD ZD ZF ZF ZF XH TYP. EM EMEMEM (STRUCTURAL FASCIA)(STRUCTURAL FASCIA)(STRUCTURAL FASCIA)(STRUCTURAL FASCIA)(STRUCTURAL FASCIA) RB 11 (STRUCTURAL FASCIA)RB 1 3 BETWEEN BOTTOM AND MIDDLE MOMENT FRAME BEAMS BETWEEN BOTTOM AND MIDDLE MOMENT FRAME BEAMS DROPPED BELOW STAIR LANDING DROPPED BELOW STAIR LANDING BETWEEN BOTTOM AND MIDDLE MOMENT FRAME BEAMS BETWEEN BOTTOM AND MIDDLE MOMENT FRAME BEAMS DROPPED BELOW STAIR LANDING DROPPED BELOW STAIR LANDING P 03 IE IE IEIE IE IE IEIE P 03 P 1 7 P 1 7 P 17 P 1 7 P 1 6 P 16 P 1 6 P 1 6 P 1 6 P 16 P 1 6 P 1 6 BEAM SCHEDULE MARK TYPE UB 01 (2) 2 X 6 UB 02 (3) 1-3/4 X 11-7/8 LVL UB 03 (3) 2 X 6 UB 04 W10X26 UB 05 W10X26 UB 06 W10X26 UB 07 W10X26 UB 08 (3) 2 X 6 UB 09 (2) 2 X 6 UB 10 (2) 1-3/4 X 11-7/8 LVL UB 11 (3) 2 X 6 UB 12 (3) 2 X 6 UB 13 (3) 1-3/4 X 11-7/8 LVL UB 14 (3) 2 X 8 UB 15 1-3/4 X 11-7/8 LVL UB 16 1-3/4 X 11-7/8 LVL UB 17 (2) 2 X 6 UB 18 (2) 2 X 6 UB 19 (2) 1-3/4 X 11-7/8 LVL UB 20 (2) 2 X 6 UB 21 (2) 1-3/4 X 11-7/8 LVL UB 22 (2) 1-3/4 X 11-7/8 LVL UB 23 (3) 2 X 6 UB 24 (3) 2 X 8 UB 25 (3) 2 X 8 UB 26 (3) 2 X 8 UB 27 (2) 2 X 6 UB 28 W10X26 UB 29 (2) 1-3/4 X 11-7/8 LVL 1. DIMENSIONAL LUMBER DF #2 U.N.O. 2. LAMINATED VENEER LUMBER (LVL) 2.0E 3. GLUED-LAMINATED TIMBER (GLB) 24F-1.8E 4. STEEL W-SHAPES A992-50 5. SUFFIXES (A, B, ETC.) DENOTE ALTERNATIVES FOR THE SPECIFIED BEAM 6. ALL HEADERS IN BEARING WALLS TO HAVE MIN. (1) TRIMMER & (1) KING STUD U.N.O. ALL OTHER BEAMS AND GIRDER TRUSSES TO HAVE MIN. (2) 2X SUPPORTS U.N.O. SHEATHING SCHEDULE TYPE THICKNESS FLOOR 3/4" OSB (48/24 SPAN RATING) ROOF 7/16" OSB (24/16 SPAN RATING) 1. SHEATHING PERPENDICULAR TO SUPPORTS. 2. FLOOR SHEATHING NAILED & GLUED TO SUPPORT 3. 8d COMMON NAILS 6" O.C. (EDGES) 12" O.C. (FIELD) 4. NAILING NO CLOSER THAN 3/8" FROM PANEL EDGE FLOOR JOIST SCHEDULE MARK TYPE FJ 01 11-7/8" TJI 210 @ 16" O.C. FJ 02 11-7/8" TJI 210 @ 12" O.C. 1. DIMENSIONAL LUMBER DF #2 U.N.O. 2. SUFFIXES (A, B, ETC.) DENOTE ALTERNATIVES FOR THE SPECIFIED JOIST POST SCHEDULE MARK TYPE P 03 (3) 2X POST P 04 (4) 2X POST P 06 4 X 6 POST P 16 W10X26 P 17 W8X18 T 02 (2) TRIM 1. PARALLEL STRAND LUMBER (PSL) 1.8E 2. STEEL PIPE (PIPE STD) A53 3. STEEL HOLLOW SECTION (HSS) A500 4. STEEL COLUMNS REQUIRE BEARING PLATES 5. CONTINUE POSTS TO FDN / STRUCT MEMBER WOOD TRUSS LOADS GROUND SNOW LOAD, Pg = 50 PSF FLAT ROOF SNOW LOAD = 35 PSF TOP CHORD DEAD LOAD = 10 PSF BOTTOM CHORD DEAD LOAD = 5 PSF 1. DESIGN SNOW LOADS SHALL BE IN ACCORDANCE WITH ASCE 7-16 CHAP.7 (2018 IBC 1608.1) ROOF RAFTER SCHEDULE MARK TYPE RR 01 2 X 6 @ 24" O.C. RR 02 2 X 10 @ 24" O.C. 1. DIMENSIONAL LUMBER DF #2 U.N.O. 2. SUFFIXES (A, B, ETC.) DENOTE ALTERNATIVES FOR THE SPECIFIED RAFTER BEAM SCHEDULE MARK TYPE RB 01 (2) 2 X 6 RB 02 (3) 1-3/4 X 9-1/2 LVL RB 03 (3) 2 X 6 RB 04 (2) 2 X 8 RB 05 W10X26 RB 06 (2) 2 X 6 RB 07 (3) 2 X 6 RB 08 W10X26 RB 09 (2) 2 X 6 RB 10 (3) 2 X 10 RB 11 (2) 2 X 6 RB 12 (3) 2 X 6 RB 13 (3) 2 X 6 RB 14 (2) 2 X 6 RB 15 (2) 2 X 6 RB 16 (2) 2 X 6 RB 17 (3) 2 X 8 RB 18 (2) 2 X 6 RB 19 (2) 2 X 6 RB 20 (2) 2 X 6 RB 21 (3) 2 X 6 RB 22 (2) 2 X 6 RB 23 (2) 2 X 6 1. DIMENSIONAL LUMBER DF #2 U.N.O. 2. LAMINATED VENEER LUMBER (LVL) 2.0E 3. GLUED-LAMINATED TIMBER (GLB) 24F-1.8E 4. STEEL W-SHAPES A992-50 5. SUFFIXES (A, B, ETC.) DENOTE ALTERNATIVES FOR THE SPECIFIED BEAM 6. ALL HEADERS IN BEARING WALLS TO HAVE MIN. (1) TRIMMER & (1) KING STUD U.N.O. ALL OTHER BEAMS AND GIRDER TRUSSES TO HAVE MIN. (2) 2X SUPPORTS U.N.O. 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS HA R R I S A R C H I T E C T U R E M A D I S O N S Q U A R E AP A R T M E N T S ( R E X B U R G ) -- - -- - -- -- 01 SEP 2020 1810720 KZG MCW - - - - - -- - TH I R D F L O O R / L O W E R R O O F F R A M I N G P L A N 3/16" = 1'-0" S3-0 THIRD FLOOR/LOWER ROOF FRAMING PLAN 3/16" = 1'-0" P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/20/2020 SW 1 D D SW 1 D D NO H O L D - D O W N S R E Q U I R E D SW 1 SW 1 D D SW1 D D SW1 D D SW1 D D SW1 D D NO HOLD-DOWNS REQUIRED SW1 FH NO HOLD-DOWNS REQUIRED SW1 FH EM EM SW 1 D D SW 1 D D NO H O L D - D O W N S R E Q U I R E D SW 1 SW 1 D D SW1 D D SW1 D D SW1 D D SW1 D D NO HOLD-DOWNS REQUIRED SW1 FH NO HOLD-DOWNS REQUIRED SW1 FH EM EM GT TYP. HTYP. GX TYP. SHEAR WALL SCHEDULE MARK SHEATHING EDGE NAILING ABUTTING PANEL EDGE FRAMING ANCHORAGE SOLE PLATE SILL PLATE SW1 7/16"8d @ 6"2X 10d @ 6"5/8" A.B. @ 32" SW2 7/16"8d @ 4"2X 10d @ 8"5/8" A.B. @ 32" SW3 7/16"8d @ 3"3X or (2)2X 10d @ 12"5/8" A.B. @ 32" 1. SHEATHING SHALL CONSIST OF WOOD STRUCTURAL PANELS (SEE GSN). 2. UNLESS NOTED ON DRAWINGS, EXTERIOR STUDS SHALL BE SPACED AT 16" O.C. 3. SHEATHING NAILS SHALL BE COMMON OR GALVANIZED BOX NAILS. - FIELD NAIL SPACING SHALL BE 12" FOR STUDS SPACED 16" O.C. OR LESS AND 6" O.C. FOR STUDS SPACED AT 24" O.C. 4. FOR SW1 ONLY, EDGE NAILS MAY BE SUBSTITUTED WITH 1-1/2" 16 GAGE STAPLES SPACED AT 3" O.C. AND FIELD NAILS MAY BE SUBSTITUTED WITH 16 GAGE STAPLES AT 12" O.C. 5. ANCHORAGE NAILS SHALL BE COMMON NAILS. 6. ANCHOR BOLTS SHALL HAVE A 3X3X0.229" WASHER AND 7" MIN EMBEDMENT. THE WASHER SHALL EXTEND TO WITHIN 1/2" FROM THE SHEATHING. 7. FOR SW3, SW4, SW7, AND SW8, (2) 2" NOMINAL FRAMING STITCH-NAILED TOGETHER WITH (2) 10d NAILS @ 6" MAY BE USED AT ABUTTING PANEL EDGES IN PLACE OF 3" NOMINAL FRAMING. HOLD-DOWN SCHEDULE MARK HOLD-DOWN MINIMUM FASTENERS ANCHOR POST A LSTHD8 10d X 2-1/2" (.148 X 2-1/2")STRAP 8" EMBED.(2) 2X POST B STHD10 10d X 2-1/2" (.148 X 2-1/2")STRAP 10" EMBED.(2) 2X POST D CS16 (11" END LENGTHS) 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST E MST37 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST F MST48 10d X 2-1/2" (.148 X 2-1/2")(FLOOR STRAP)(2) 2X POST J HDU2-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)5/8" A.B. 5" EMBED.(2) 2X POST K HDU4-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)5/8" A.B. 5" EMBED.(2) 2X POST L HDU5-SDS2.5 SDS1/4" X 2-1/2" (SDS25212) FOUNDATION WALL: SB5/8X24 FOOTING: 5/8" A.B. 7" EMBED. (2) 2X POST N HDU11-SDS2.5 SDS1/4" X 2-1/2" (SDS25212)1" A.B. 9" EMBED.4 X 6 POST 1. HOLD-DOWNS SHALL BE SIMPSON STRONG-TIE OR EQUIVALENT. 2. SHEAR WALL EDGE NAILING SHALL BE TO HOLD-DOWN POST. 3. STHD STRAPS SHALL BE "RJ" TYPE AT RIM JOIST LOCATIONS. 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS HA R R I S A R C H I T E C T U R E M A D I S O N S Q U A R E AP A R T M E N T S ( R E X B U R G ) -- - -- - -- -- 01 SEP 2020 1810720 KZG MCW - - - - - -- - TH I R D F L O O R S H E A R W A L L 3/16" = 1'-0" S3-1 THIRD FLOOR SHEAR WALL 3/16" = 1'-0" P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/20/2020 GIRDER TRUSS GI R D E R T R U S S GI R D E R T R U S S GIRDER TRUSS GI R D E R T R U S S GI R D E R T R U S S GIRDER TRUSS PRE - M A N U F A C T U R E D R O O F T R U S S E S @ 2 4 " O . C . P R E - M A N U F A C T U R E D R O O F T R U S S E S @ 2 4 " O . C . RR 0 1 RR 01 RR 02 RB 01 RB 01 RB 01RB 01 RR 0 2RR 02 RR 0 2 RB 02 (BOTTOM OF BEAM FLUSH WITH BOTTOM OF TRUSSES) RB 02 (BOTTOM OF BEAM FLUSH WITH BOTTOM OF TRUSSES) RB 02 (BOTTOM OF BEAM FLUSH WITH BOTTOM OF TRUSSES) RB 02 (BOTTOM OF BEAM FLUSH WITH BOTTOM OF TRUSSES)RB 03 RB 03 RB 03 RB 03 RB 0 4 RB 0 4 RB 0 4 RB 0 4 RB 0 5 RB 0 5 RB 06 RB 0 7 RB 0 7 (A B O V E ) (A B O V E ) RB 06 DO U B L E R A F T E R DO U B L E R A F T E R RB 0 5 RB 0 5 RB 06 RB 0 7 RB 0 7 (A B O V E ) (A B O V E ) RB 06 HANG RB07 FROM GIRDER TRUSS WITH HUC26-3 HANGER OR EQUIVALENT. DESIGN GIRDER TRUSS FOR POINT LOAD: SNOW: 160# DEAD: -80# (MAXIMUM UPLIFT: 405#) HANG RB07 FROM GIRDER TRUSS WITH HUC26-3 HANGER OR EQUIVALENT. DESIGN GIRDER TRUSS FOR POINT LOAD: SNOW: 160# DEAD: -80# (MAXIMUM UPLIFT: 405#) HANG RB07 FROM GIRDER TRUSS WITH HUC26-3 HANGER OR EQUIVALENT. DESIGN GIRDER TRUSS FOR POINT LOAD: SNOW: 160# DEAD: -80# (MAXIMUM UPLIFT: 405#) HANG RB07 FROM GIRDER TRUSS WITH HUC26-3 HANGER OR EQUIVALENT. DESIGN GIRDER TRUSS FOR POINT LOAD: SNOW: 160# DEAD: -80# (MAXIMUM UPLIFT: 405#) HANG DOUBLE RAFTERS FROM GIRDER TRUSS WITH HUC26-2 HANGER OR EQUIVALENT. DESIGN GIRDER TRUSS FOR POINT LOAD: SNOW: 160# DEAD: 35# (MAXIMUM UPLIFT: 100#) HANG DOUBLE RAFTERS FROM GIRDER TRUSS WITH HUC26-2 HANGER OR EQUIVALENT. DESIGN GIRDER TRUSS FOR POINT LOAD: SNOW: 160# DEAD: 35# (MAXIMUM UPLIFT: 100#) RB 08 T 0 2 T 0 2 RB 09RB 09 RB 10 RB 10 T 0 2 T 0 2 RB 09RB 09 RB 10 RB 10 IA TYP.Q TYP.AP TYP. F TYP. GU TYP. RB 08 DO U B L E R A F T E R DO U B L E R A F T E R HUC26-2 HANGER OR EQUIVALENT UPSIDE DOWN HUC26-2 HANGER OR EQUIVALENT UPSIDE DOWN LUS26-3 HANGER OR EQUIVALENT UPSIDE DOWN LUS26-3 HANGER OR EQUIVALENT UPSIDE DOWN LUS26-3 HANGER OR EQUIVALENT UPSIDE DOWN LUS26-3 HANGER OR EQUIVALENT HUC26-2 HANGER WITH (4) 1" LAP JOINT FILLET WELDS OR EQUIVALENT. HUC26-2 HANGER WITH (4) 1" LAP JOINT FILLET WELDS OR EQUIVALENT. HUC26-2 HANGER WITH (4) 1" LAP JOINT FILLET WELDS OR EQUIVALENT. HUC26-2 HANGER WITH (4) 1" LAP JOINT FILLET WELDS OR EQUIVALENT. ZDZD ZDZD ZD ZDZDZD ZFZF XHTYP. PRE - M A N U F A C T U R E D R O O F T R U S S E S @ 2 4 " O . C . P R E - M A N U F A C T U R E D R O O F T R U S S E S @ 2 4 " O . C . EM EM EM EM IY (3) ROWS SDW22500 SCREWS @ 12" O.C. IY (3) ROWS SDW22500 SCREWS @ 12" O.C. IY (3) ROWS SDW22500 SCREWS @ 12" O.C. IY (3) ROWS SDW22500 SCREWS @ 12" O.C. (STRUCTURAL FASCIA)(STRUCTURAL FASCIA) P 1 7 P 1 7 P 1 7 P 1 7 P 1 6 P 16 P 16 P 1 6 P 1 6 P 16 P 16 P 1 6 WOOD TRUSS LOADS GROUND SNOW LOAD, Pg = 50 PSF FLAT ROOF SNOW LOAD = 35 PSF TOP CHORD DEAD LOAD = 10 PSF BOTTOM CHORD DEAD LOAD = 5 PSF 1. DESIGN SNOW LOADS SHALL BE IN ACCORDANCE WITH ASCE 7-16 CHAP.7 (2018 IBC 1608.1) SHEATHING SCHEDULE TYPE THICKNESS FLOOR 3/4" OSB (48/24 SPAN RATING) ROOF 7/16" OSB (24/16 SPAN RATING) 1. SHEATHING PERPENDICULAR TO SUPPORTS. 2. FLOOR SHEATHING NAILED & GLUED TO SUPPORT 3. 8d COMMON NAILS 6" O.C. (EDGES) 12" O.C. (FIELD) 4. NAILING NO CLOSER THAN 3/8" FROM PANEL EDGE ROOF RAFTER SCHEDULE MARK TYPE RR 01 2 X 6 @ 24" O.C. RR 02 2 X 10 @ 24" O.C. 1. DIMENSIONAL LUMBER DF #2 U.N.O. 2. SUFFIXES (A, B, ETC.) DENOTE ALTERNATIVES FOR THE SPECIFIED RAFTER POST SCHEDULE MARK TYPE P 03 (3) 2X POST P 04 (4) 2X POST P 06 4 X 6 POST P 16 W10X26 P 17 W8X18 T 02 (2) TRIM 1. PARALLEL STRAND LUMBER (PSL) 1.8E 2. STEEL PIPE (PIPE STD) A53 3. STEEL HOLLOW SECTION (HSS) A500 4. STEEL COLUMNS REQUIRE BEARING PLATES 5. CONTINUE POSTS TO FDN / STRUCT MEMBER BEAM SCHEDULE MARK TYPE RB 01 (2) 2 X 6 RB 02 (3) 1-3/4 X 9-1/2 LVL RB 03 (3) 2 X 6 RB 04 (2) 2 X 8 RB 05 W10X26 RB 06 (2) 2 X 6 RB 07 (3) 2 X 6 RB 08 W10X26 RB 09 (2) 2 X 6 RB 10 (3) 2 X 10 RB 11 (2) 2 X 6 RB 12 (3) 2 X 6 RB 13 (3) 2 X 6 RB 14 (2) 2 X 6 RB 15 (2) 2 X 6 RB 16 (2) 2 X 6 RB 17 (3) 2 X 8 RB 18 (2) 2 X 6 RB 19 (2) 2 X 6 RB 20 (2) 2 X 6 RB 21 (3) 2 X 6 RB 22 (2) 2 X 6 RB 23 (2) 2 X 6 1. DIMENSIONAL LUMBER DF #2 U.N.O. 2. LAMINATED VENEER LUMBER (LVL) 2.0E 3. GLUED-LAMINATED TIMBER (GLB) 24F-1.8E 4. STEEL W-SHAPES A992-50 5. SUFFIXES (A, B, ETC.) DENOTE ALTERNATIVES FOR THE SPECIFIED BEAM 6. ALL HEADERS IN BEARING WALLS TO HAVE MIN. (1) TRIMMER & (1) KING STUD U.N.O. ALL OTHER BEAMS AND GIRDER TRUSSES TO HAVE MIN. (2) 2X SUPPORTS U.N.O. 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS HA R R I S A R C H I T E C T U R E M A D I S O N S Q U A R E AP A R T M E N T S ( R E X B U R G ) -- - -- - -- -- 01 SEP 2020 1810720 KZG MCW - - - - - -- - UP P E R R O O F F R A M I N G 3/16" = 1'-0" S4-0 UPPER ROOF FRAMING 3/16" = 1'-0" P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/20/2020 DE T A I L S H E E T S A N D N O T E S FOUNDATION WALL - CONCRETE LINTEL NO SCALEE NOTE: EXTEND REINFORCEMENT 24" BEYOND OPENING ON EACH SIDE. WHERE SPACE IS LIMITED, EXTEND 12" BEYOND OPENING WITH 90° HOOK. 6'-0" MAX OPENING 24" (SEE NOTE) (1) #4 BAR (2) #4 BARS 2" COVER 2" C O V E R 8" MIN. 2" F O R E A C H FO O T O F OP E N I N G (6 " M I N . ) 3" M I N . (1) #4 BAR SUPPORT OVER-BUILD ON FULL WIDTH OR MULTIPLE 2X LEDGER FASTEN TO LOWER FRAMING WITH (4) 10dX3" NAILS @ EACH TRUSS OR RAFTER BELOW LOWER ROOF FRAMING OR WOOD TRUSSES RIDGE OR HIP BEAM (SEE TABLE) OVER-BUILD RAFTERS (SEE TABLE) OR WOOD TRUSS @ 24" O.C. U.N.O. PROVIDE ROOF SHEATHING ON LOWER ROOF (SEE SHEATHING SCHEDULE) FLAT ROOF SNOW LOAD KICKER SIZE RAFTER SIZE RIDGE BEAM SIZE 0-40 PSF 2X4 2X4 2X6 40-80 PSF 2X6 2X4 2X6 80-120 PSF*(2) 2X4 2X6 2X8 1.SUPPORT ALL RAFTERS AND RIDGE BEAMS WITH KICKERS SPACED AT 48" O.C. MAX. SUPPORT KICKERS ON FRAMING BELOW. *2. FOR SNOW LOADS OF 80-120PSF, ATTACH EACH KICKER TO FRAMING BELOW WITH (1) A35 CLIP. ATTACH RAFTER TO LEDGER WITH (3) 10d TOE NAILS ROOF FRAMING - OVER BUILD FRAMING NO SCALEF 2X KICKERS (SEE TABLE) ATTACH KICKERS TO FRAMING BELOW WITH (3) 10d TOE NAILS HOLD-DOWN - FLOOR STRAP EN D L E N G T H EN D L E N G T H CL E A R S P A N POST (SEE HOLD-DOWN SCHEDULE) FLOOR-TO-FLOOR STRAP (SEE HOLD-DOWN SCHEDULE) PROVIDE MINIMUM 1-5/8" TO FIRST NAIL PROVIDE MAX NAILING IN EACH END LENGTH (SEE HOLD-DOWN SCHEDULE FOR FASTENER TYPE) NAILS NOT REQUIRED IN CLEAR SPAN PROVIDE EQUAL END LENGTHS NO SCALEH BEARING WALL - EXTERIOR TO FLOOR(150 PLF UNIT SHEAR) NO SCALEP SOLID BLOCKING AT WALL SHEATHING PANEL EDGES 2X DOUBLE TOP PLATE (2) 8d NAILS EACH JOIST 10dX3" @ 6" O.C. PANEL EDGE NAILING TO RIM BOARD RIM BOARD SHEATHING CONTINUOUS ACROSS JOISTS OR LTP4 PLATE EVERY 24" O.C. ALONG PANEL JOINTS 2X STUD WALL SOLE PLATE (BOTTOM PLATE) SOLE PLATE NAILING PROVIDE FULL-HEIGHT BLOCKING @ 48" O.C. IN FIRST TWO BAYS WHEN JOISTS ARE PARALLEL TO WALL OR PROVIDE GYPSUM BOARD TO FLOOR ASSEMBLY PROVIDE MINIMUM JOIST BEARING (SEE MANUFACTURER) FLOOR JOISTS (SEE STRUCTURAL) FLOOR SHEATHING ROOF RAFTER WOOD TRUSS H2.5A AT EACH RAFTER BEARING ROOF RAFTER (SEE STRUCTURAL) DIAPHRAGM BOUNDARY NAILING FULL-HEIGHT SOLID BLOCKING (EVERY THIRD BLOCK MAY BE TURNED FLATWISE FOR VENTILATION) NO SCALE ROOF FRAMING - BLOCKING (150 PLF UNIT SHEAR)Q MULTI-PLY TRUSS TO TOP PLATE CONNECTION TRUSS UPLIFT TIE-DOWN <520 LB (2) H2.5A <650 LB SDWC15600 SCREW <1040 LB H10A OR H10A-2 <1310 LB HTS16 UPLIFTS TO BE PROVIDED BY TRUSS MANUFACTURER UPLIFT CAPACITIES ARE BASED ON DOUGLAS FIR H1 OR SDWC15600 AT EACH SINGLE TRUSS BEARING (SEE TABLE FOR MULTI-PLY TRUSSES.) WOOD TRUSS DIAPHRAGM BOUNDARY NAILING 10dx3" @ 6" O.C. FULL-HEIGHT SOLID BLOCKING OR PREFABRICATED TRUSS BLOCKING (FOR SOLID BLOCKS, EVERY THIRD BLOCK MAY BE TURNED FLATWISE FOR VENTILATION) VPA CONNECTOR OR ATTACH RAFTER TO BEVELED PLATE WITH (3) 10d NAILS AT EACH RAFTER (BEVELED PLATE TO TOP PLATE NAILING TO MATCH DOUBLE TOP PLATE NAILING) WEB STIFFENERS REQUIRED FOR I-JOIST RAFTERS A35 OR RBC CLIP AT EACH BLOCK FLOOR SHEATHING (SEE FLOOR SHEATHING SCHEDULE) FLOOR JOISTS (SEE STRUCTURAL) FULL-HEIGHT BLOCKING BETWEEN JOISTS OR WOOD TRUSSES DOUBLE TOP PLATE NO SCALER BEARING WALL - INTERIOR TO FLOOR NO SCALES FOUNDATION WALL CORNER DOWELS TYP. @ FOOTINGS & FOUNDATION CORNER INTERSECTION REQUIRED LAP LENGTH CONCRETE 12 BAR DIA. 40 BAR DIA. HORIZONTAL REINFORCING AS CALLED OUT IN GENERAL STRUCTURAL NOTES OR STRUCTURAL DRAWINGS HOOK TYPE SPLICE HO O K 12" 24" MASONRY 20 BAR DIA. 48 BAR DIA. MIN. SPLICE FOUNDATION WALL - CORNER & INTERSECTION REINFORCING SE E G E N E R A L S T R U C T U R A L N O T E S MI N . F R O S T D E P T H 3" C L R . 3" 2X STUD WALL ANCHOR BOLT (SEE SHEAR WALL SCHEDULE FOR SPACING) WITH 3X3X0.229" PL WASHER CONCRETE SLAB ROUGHENED SURFACE WITH 1/4" MIN. IRREGULARITIES DOWELS TO MATCH VERTICAL WALL REINFORCING CONCRETE FOOTING (SEE STRUCTURAL) SHEATHING (SEE SHEAR WALL SCHEDULE) 2X TREATED SILL PLATE FOUNDATION WALL - SLAB ON GRADE NO SCALEV CONCRETE FOUNDATION WALL (SEE STRUCTURAL) TRUSSES A35 CLIPS WALL SHEATHING 2X BLOCKING (A35 AND 2X BLOCKING NOT REQUIRED WHERE HANGER ATTACHES TO RIM BOARD OR 2X MEMBER) 2X WALL STUD 2X STUD WALL A35 CLIP 2X BLOCKING (NOT REQUIRED WHERE HANGER ATTACHES TO BEAM OR RIM BOARD) TRUSS HANGER (SEE MANUFACTURER) TRUSS BOTTOM CHORD 2X BLOCKING BETWEEN TRUSSES ROOF SHEATHING (SEE STRUCTURAL) TRUSS TOP CHORD WOOD TRUSS - WALL/BEAM NO SCALEW PLAN VIEW SECTION HOLD-DOWN (SEE STRUCTURAL) SEE SHEAR WALL SCHEDULE FOR ANCHOR BOLTS SIZE AND SPACING ADDITIONAL STRAPPING AND BLOCKING AROUND OPENINGS ARE NOT REQUIRED. WINDOW OPENING (WHERE OCCURS) DOOR OPENING (WHERE OCCURS) PROVIDE EDGE NAILING ALONG FULL HEIGHT OF HOLD-DOWN POST SEE STRUCTURAL PLAN FOR SHEAR WALL EXTENT AND REQUIREMENTS SHEAR WALL - PERFORATED NO SCALEY POST (SEE HOLD-DOWN SCHEDULE) EMBEDDED FOUNDATION STRAP (SEE HOLD-DOWN SCHEDULE) RIM BOARD WHERE OCCURS CL E A R S P A N 17 " M A X I M U M NA I L E D P O R T I O N HORIZONTAL REINFORCEMENT AT TOP OF FOUNDATION (SEE FOUNDATION WALL SCHEDULE) 1/2" MIN. FROM CORNER HOLD-DOWN - FOUNDATION STRAP NO SCALEAD 4" TYP. 1" T Y P . 4'-0" MINIMUM BETWEEN SPLICES TOP PLATE TO LOWER PLATE: 12 - 16d NAILS (2 ROWS OF 6) LOWER PLATE TO TOP OF STUDS: 2 - 16d NAILS AT EACH STUD 8'-0" MINIMUM TO NEXT LAP NOTE: WHERE DOUBLE TOP PLATE IS CUT DUE TO INTERSECTING BEAMS, WALLS, ETC. PROVIDE (2) CS16 STRAPS ACROSS CUT WITH 12" END LENGTHS DIAPHRAGM - TOP PLATE SPLICE NO SCALEAP NOTE: FASTENERS IN PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED WOOD SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER ANCHORAGE DEVICE (SEE HOLD-DOWN SCHEDULE) ANCHOR BOLT (SEE HOLD-DOWN SCHEDULE FOR BOLT DIAMETER AND EMBEDMENT LENGTH) POST (SEE HOLD-DOWN SCHEDULE) HOLD-DOWN NO SCALEBL LE N G T H 8" MIN. MINIMUM EDGE DISTANCE HOLD-DOWN (MAY BE PLACED ABOVE FLOOR JOISTS USING COUPLER NUT AND EXTENSION ROD) DRILL AND EPOXY A36 THREADED ROD (SEE TABLE FOR DIAMETER, EMBEDMENT LENGTH AND MINIMUM EDGE DISTANCE) FOUNDATION WALL NOTES: 1. EPOXY SHALL BE SIMPSON SET-XP OR EQUIVALENT. SEE MANUFACTURER FOR INSTALLATION REQUIREMENTS. 2. ALL PRODUCTS ARE SIMPSON DESIGNATIONS, EQUIVALENT ANCHORS AND HOLD-DOWNS ARE PERMITTED. EPOXY RETROFIT FOR MISPLACED STHD REPLACEMENT EPOXY ANCHORREPLACEMENT HOLD-DOWN SPECIFIED STRAP DIA.LENGTH MIN. EDGE DIST. HDU2 5/8"8"1-3/4"LSTHD8 HDU4 5/8"12"1-3/4"STHD10 HDU5 5/8"16"1-3/4"STHD14 NO SCALEBSRETROFIT EPOXY ANCHOR IN FOUNDATION WALL 8d @ 4" O.C. BLOCKING BETWEEN TRUSSES MONO TRUSSES SET-BACK GABLE TRUSS PROVIDE 2X BLOCKING IN TRUSS 10d @ 4" O.C. FLOOR SYSTEM (SEE STRUCTURAL) 8d @ 4" O.C. BLOCKING OR LEDGER REQUIRED MONO TRUSSES OR RAFTERS 2X STUD WALL BLOCKING REQUIRED BETWEEN STUDS FLOOR SHEATHING CONTINUOUS SHEATHING REQUIRED 10d @ 4" O.C. NO SCALECISHEAR TRANSFER - SET-BACK WALL/GABLE - LOWER ROOF SET-BACK WALL SET-BACK GABLE SHEAR WALL AT PARTY WALL - JOISTS NO SCALECQ 2X SOLE PLATE 2X STUD WALL RIM BOARD 2X DOUBLE TOP PLATE FLOOR SHEATHING (SEE SHEATHING SCHEDULE) FLOOR JOIST (SEE STRUCTURAL) PROVIDE FULL-HEIGHT BLOCKING @ 48" O.C. IN FIRST TWO BAYS WHEN JOISTS ARE PARALLEL TO WALL OR PROVIDE GYPSUM BOARD TO FLOOR ASSEMBLY SHEATHING (SEE SHEAR WALL SCHEDULE) TO BE APPLIED TO EITHER SIDE OF FRAMED WALL A35 CLIPS (OR EQUIVALENT) REQUIRED IF SHEATHING NOT CONTINUOUS ACROSS JOISTS (SEE SCHEDULE ABOVE FOR SPACING) SW1 SW2 SW3 A35 @ 24" O.C. A35 @ 16" O.C. A35 @ 12" O.C. SW4 A35 @ 9" O.C. (3) 8d NAILS EACH JOIST/BLOCK SOLE PLATE NAILING NOTE: SELECT SPACING BASED ON SHEAR WALL OF LOWER FLOOR FLOOR SYSTEM (WHERE OCCURS) 8d @ 4" O.C. 2X STUD WALL 2X BLOCKING REQUIRED BETWEEN STUDS PARALLEL WITH THE SLOPE OF THE ROOF TRUSSES CONTINUOUS SHEATHING (WHERE FLOOR SYSTEM OCCURS) ROOF SHEATHING ROOF TRUSSES 10d @ 4" O.C. SHEAR WALL - DIAPHRAGM TRANSFER (TRUSS PARALLEL) NO SCALECT LEDGER (SEE STRUCTURAL) 2X STUD WALL SCREWS OR NAILS (SEE STRUCTURAL) 2X BLOCKING TO MATCH LEDGER SIZE. A35 CLIPS AND BLOCKING NOT REQUIRED WHERE LEDGER IS ATTACHED TO RIM BOARD OR 2X MEMBER A35 CLIPS ROOF RAFTER SLOPE TO MATCH ARCHITECTURAL (SEE STRUCTURAL)RAFTER HANGER SCREWS OR NAILS (SEE STRUCTURAL) RAFTERS A35 CLIP BLOCKING NO SCALECULEDGER - RAFTER TO FRAMED WALL PLAN VIEW SECTION FO O T I N G D E P T H (S E E S T R U C T U R A L ) 4" FOOTING WIDTH (SEE STRUCTURAL) 3" 3" 3" 3" NOTE: FASTENERS IN PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED WOOD SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE, OR COPPER. LENGTHWISE REINFORCEMENT (SEE STRUCTURAL) CONCRETE NAILS @ 16" O.C. (ANCHOR BOLTS REQUIRED AT SHEAR WALLS PER SHEAR WALL SCHEDULE) 2X STUD WALL CONCRETE SLAB (WHERE OCCURS) 1 1 AT OPTIONAL MONOLITHIC FOOTING NO SCALECWBEARING WALL - INTERIOR FOOTING SHEAR WALL - ROOF DIAPHRAGM CONNECTION NO SCALEEM SHEAR WALL PRE-FABRICATED TRUSS BLOCKING OR SHEAR WALL PERPENDICULAR TO TRUSSES PARALLEL TO TRUSSES DOUBLE TOP PLATE SIMPSON LTP4 @ 16" O.C. OR A35 @ 12" O.C. 2X FRAMING NAILING - SAME AS SHEAR WALL BELOW NAIL BLOCKING TO TRUSSES WITH 16d NAILS @ 6" O.C. SHEATHING ROOF SHEATHING 10d @ 3" O.C. SHEATHING ROOF SHEATHING DRAG TRUSS OR FRAMED WALL WITH SHEATHING AND NAILING SAME AS SHEAR WALL ALIGNED BELOW DOUBLE TOP PLATE 10d @ 3" O.C. SIMPSON A35 @ 12" O.C. OR LTP4 @ 16" O.C. SHEAR WALL (SEE STRUCTURAL) 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS HA R R I S A R C H I T E C T U R E M A D I S O N S Q U A R E AP A R T M E N T S ( R E X B U R G ) -- - -- - -- -- 01 SEP 2020 1810720 KZG MCW - - - - - -- - ST R U C T U R A L D E T A I L S NTS SD1 P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/20/2020 DE T A I L S H E E T S A N D N O T E S FLOOR INSIDE FOUNDATION NO SCALEZA 6" MI N . SEE FLOOR FRAMING PLAN FOR SIZE AND SPACING RIM BOARD OR FULL HEIGHT SOLID BLOCKING BETWEEN JOISTS PRESSURE TREATED DOUBLE SILL PLATE FIN. GRADE 2X STUD WALL P.T. SILL PLATE 1/2" AIR GAP OR MOISTURE BARRIER DOUBLE TOP PLATE CONCRETE FOUNDATION WALL (SEE STRUCTURAL) CONCRETE FOOTING (SEE STRUCTURAL) ROUGHEN SURFACE W/ AT LEAST 1/4" IRREGULARITIES GW, GP, SW AND SP SOILS MI N . F R O S T D E P T H (S E E S T R U C T U R A L ) 3" C L R . 3" CLR. CONCRETE SLAB (WHERE OCCURS) ANCHOR BOLT (SEE SHEAR WALL SCHEDULE FOR SIZE AND SPACING) WITH A 3X3X0.229" FLAT WASHER AND 7" MINIMUM EMBEDMENT SOLE PLATE BREEZEWAY TO WOOD WALL NO SCALEZB SOLE PLATE NAILING 4000PSI CONCRETE 6" CONCRETE DECK SLOPING TO 5" (MIN.) 20 GAGE W2 FORMLOK DECKING #4@18" O.C. EACH DIRECTION (4) 1/2" DIA PUDDLE WELDS PER PANEL 1/2" DIA. BOLTS @ 16" O.C. L8X4X1/2 (LONG-LEG UP) NOTE: PROVIDE TEMPORARY SHORING AT MID SPAN CONTINUOUS (2) 1.75X 11-7/8" LVL BLOCKING A35 @ 12" O.C. PROFILE 2" (2) ROWS 1/2" DIA. BOLTS @ 16" O.C. STEEL COLUMN - BASE PLATEZE 5" 2" MIN. SEE STRUCTURAL FOR BASE PLATE DIMENSIONS W-SHAPED COLUMN (SEE STRUCTURAL) 3/4" DIA. F1554 GR. 36 THREADED ROD MIN. 7" EMBEDMENT WITH SIMPSON SET-XP EPOXY OR EQUIVALENT NO SCALE 1/4" SHEAR PLATE CONNECTION - COLUMN FLANGE NO SCALEZG W-SHAPE BEAM (SEE STRUCTURAL) W-SHAPE COLUMN (SEE STRUCTURAL) E701/4 3/4" DIA. BOLTS @ 3" O.C. FULL WEB HEIGHT (1 1/2" EDGE DIST.) 1/4 3/8" THICK PLATE 3" 3" 1 1 2" DROPPED TOP CHORD WOOD TRUSSES SIMPSON OR USP EQUIVALENT H1, H2.5 OR H2.5A ANCHORS EVERY RAFTER EACH BEARING END. USE (2) ANCHORS WHERE UPLIFT EXCEEDS 415# (SEE TRUSS MANUFACTURER). FRAMED WALL SHEATHING FASCIA BEAM (SEE STRUCTURAL) RAFTERS (SEE STRUCTURAL) 2X BLOCKING BETWEEN OUTRIGGERS WOOD TRUSS - WOOD WALL OUTRIGGER NO SCALEZF 2" CLEAR STEEL BEAM TO CONCRETE DECK NO SCALEZC CONCRETE DECK #4 BARS @ 18" O.C. EACH DIRECTION CONSULT WITH STAIR MANUFACTURER FOR CONNECTION STAIR STRINGER WHERE OCCURS (BY OTHERS) MINIMUM OF (4) SHEAR STUDS ALONG LENGTH OF BEAM L6X4X1/4 (LONG-LEG UP) (4) 1/2" DIA PUDDLE WELDS PER PANEL W-SHAPE BEAM - SHEAR CONNECTION NO SCALEZD W-SHAPE BEAM (SEE STRUCTURAL) (4) 3/4" DIA. A325 BOLTS 3" SPACING (1-1/2" EDGE DISTANCE), TOP AND BOTTOM E70 3/16 3/16 E70 3/16 3/16 1/4"X4"X6" A36 PLATE (2) 3/4" DIA. A325 BOLTS SPACED 3" SPACING (1-1/2" EDGE DIST.) W-SHAPE COLUMN (SEE STRUCTURAL) 1/4"X5"X6-1/2" A36 PLATE, TOP AND BOTTOM E70 3/16 3/16 SEE STRUCTURAL PLAN FOR SHEAR WALL EXTENT AND REQUIREMENTS SEE SHEAR WALL SCHEDULE FOR ANCHOR BOLTS SIZE AND SPACING HOLD-DOWN IF REQUIRED (SEE STRUCTURAL) WINDOW OPENING (WHERE OCCURS) DOOR OPENING (WHERE OCCURS) CS16 (32" LONG) WITH SOLID BLOCKING AT TOP OF OPENING CS16 (32" LONG) WITH SOLID BLOCKING AT BOTTOM OF OPENING CS16 (32" LONG) WITH SOLID BLOCKING AT TOP OF OPENING PROVIDE EDGE NAILING ALONG FULL HEIGHT OF HOLD-DOWN POST SHEAR WALL - FORCE TRANSFER AROUND OPENINGS NO SCALEFH SHEAR WALL - ROOF DIAPHRAGM CONNECTION NO SCALEGT E.N. = EDGE NAILING REQUIRED WOOD STRUCTURAL PANELS (SEE SCHEDULE) 2X WALL DOUBLE TOP PLATE ABUTTING PANEL EDGE FRAMING MEMBER (SEE SCHEDULE FOR SIZE) 2X BLOCKING REQUIRED AT ALL PANEL SPLICES FIELD NAILING AT ALL INTERMEDIATE WALL STUDS (SEE SCHEDULE) EDGE NAILING AT ALL PANEL EDGES (SEE SCHEDULE) NAILS SHALL BE LOCATED AT LEAST 3/8" FROM PANEL EDGE 2X WALL SILL/SOLE PLATE (SEE SCHEDULE FOR ANCHORAGE) PROVIDE STAGGERED EDGE NAILING AT DOUBLE TOP PLATE REGARDLESS OF PANEL EDGE LOCATION E.N. E.N. E.N. E. N . E. N . E. N . ROOF OR FLOOR FRAMING CONTINUOUS PANEL JOINT EDGE NAILING AT PANEL EDGES (SEE SHEATHING SCHEDULE) DIAPHRAGM BOUNDARY NAILING (MATCH PANEL EDGE NAILING) 4'X8' WOOD STRUCTURAL PANEL (SEE SHEATHING SCHEDULE) FIELD NAILING AT INTERMEDIATE FRAMING (SEE SHEATHING SCHEDULE) WOOD STRUCTURAL PANEL DIAPHRAGM - UNBLOCKED NO SCALEGU SHEAR WALL TRANSFER - WALL INTERSECTION NO SCALEGX 2X STUDS (SEE STRUCTURAL) FULL HEIGHT 2X STUDS; STITCH NAIL TOGETHER WITH (1) ROW OF 10d NAILS @ 3" O.C. SHEAR WALL EDGE FASTENING (SEE SCHEDULE) SHEATHING (SEE STRUCTURAL) FULL HEIGHT 2X STUDS; STITCH NAIL TOGETHER WITH (2) ROWS OF 10d NAILS @ 6" O.C. SHEATHING (SEE STRUCTURAL) SHEAR WALL EDGE FASTENING (SEE SCHEDULE) 2X STUDS (SEE STRUCTURAL) OPTION 1 OPTION 2 WOOD WALL - PARTY WALL TO CONCRETE FOOTING NO SCALEHI NOTE: FASTENERS IN PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED WOOD SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. CONCRETE NAILS @ 16" O.C. (ANCHOR BOLTS REQUIRED AT SHEAR WALLS PER SHEAR WALL SCHEDULE) 3" 3"CONCRETE FOOTING (SEE STRUCTURAL) DAMPROOF WHERE REQUIRED (SEE ARCHITECTURAL) 2X STUD WALL SHEATHING (SEE SHEAR WALL SCHEDULE) CONCRETE SLAB HEADER (SEE STRUCTURAL) TWO PLIES: 10d COMMON (0.148X3") NAILS @ 24" O.C. THREE OR MORE PLIES: FACE NAILING 10d COMMON (0.148X3") NAILS @ 6" O.C. STAGGERED KING STUD MIN. (1) PLY U.N.O. TRIMMER(S) (SEE STRUCTURAL) (4)16d END NAILS OR (4) 8d TOE NAILS WOOD BEAM - WALL HEADER FRAMING NO SCALEIA (2) 5/8" DIA. LAG SCREWS WOOD STRUCTURAL MEMBER (SEE STRUCTURAL) W-SHAPE A992-50 WITH 3/8" WEB STIFFENERS AT EACH BEARING END WHERE REQUIRED 2X NAILER (RIP TO MATCH) WITH 1/2" A307 BOLTS @ 32" O.C. STAGGERED. STEEL BEAM TO WOOD COLUMN CONNECTION NO SCALEIE 10d (3")2 12" O.C. SDW22500 2 3 2 12" O.C. 24" O.C. 16" O.C. 2 12" O.C. 3 PLY FASTENER ROWS SPACING 10d (3") 2 12" O.C. SDW22338 2 3 2 12" O.C. 24" O.C. 16" O.C. 2 12" O.C. 2 PLY SDW22634 2 2 24" O.C. 16" O.C. 2 12" O.C. 4 PLY LOAD (PLF)* ALLOWABLE 280 415 450 675 900 370 550 800 1200 1600 400 600 800 * ALLOWABLE SIDE LOAD APPLIED TO EXTERIOR PLY MULTIPLE PLIES (SEE STRUCTURAL) (EACH SIDE) 16" O.C. 12" O.C. 900 1200 3 3 1015 1350 16" O.C. 12" O.C. 3 3 WOOD BEAM - MULTIPLE PLIES (SIDE LOADED) NO SCALEIY SEE STRUCTURAL PLAN FOR FASTENER SIZE AND SPACING BEAM OR GIRDER TRUSS (SEE STRUCTURAL PLANS) BEAM OR GIRDER TRUSS (SEE STRUCTURAL PLANS) DOUBLE TOP PLATE DOUBLE TOP PLATE DOUBLE TOP PLATE (2) CS16 STRAPS 24" LONG (2) CS16 STRAPS 24" LONG SLIDE STRAP BETWEEN BEAM AND WALL BEAM OR GIRDER TRUSS (SEE STRUCTURAL PLANS) (2) CS16 STRAPS (10) -10d NAILS EACH END OF EACH CS16 (CUT TO REQUIRED LENGTH) OR DSC OR EQUIVALENT DIAPHRAGM - CHORD / COLLECTOR STRAP NO SCALELF FLUSH DROPPED OFFSET BEAM (SEE STRUCTURAL) JOIST HANGER (3) 2x NAILER (RIP TO MATCH) STITCH NAILED TO BEAM W/ (2) ROWS 10d NAILS @ 6" O.C. (BLOCKING CAN BE REMOVED AS NECESSARY FOR DUCTWORK)FLOOR SHEATHING (SEE STRUCTURAL) FLOOR JOIST (SEE STRUCTURAL) FLANGES OF HANGER TO BE FULLY SUPPORTED BY BLOCKING OR BEAM PARTIALLY DROPPED BEAM WITH NAILER NO SCALEQO SHEATHING CONTINUOUS ACROSS JOINT OR ATTACH GABLE END TRUSS TO TOP PLATE WITH 10dX3" @ 6" O.C. TOE NAILING END WALL 2X6 BRACE @ 48" O.C. WOOD TRUSS ROOF SHEATHING GABLE END WOOD TRUSS ATTACH BRACE TO BLOCKING WITH (5) 10d NAILS 2X4 BLOCKING WITH (2) 10d NAILS @ EACH END 8d NAILS @ 6" O.C. WOOD TRUSS - WOOD WALL GABLE END BRACING NO SCALEXH 1 (MAX.) 1 (2) A34 OR (2) GBC @ EACH BRACE 2X BLOCKING FOR TWO BAYS AT TOP OF DIAGONAL BRACE 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS HA R R I S A R C H I T E C T U R E M A D I S O N S Q U A R E AP A R T M E N T S ( R E X B U R G ) -- - -- - -- -- 01 SEP 2020 1810720 KZG MCW - - - - - -- - ST R U C T U R A L D E T A I L S NTS SD2 P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/20/2020 TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY A N E W P R O J E C T F O R MA D I S O N S Q U A R E A P A R T M E N T S AUG. - 2020 STAFF REXBURG, ID Engineered Systems Associates OCT. 19, 2020 BA S E M E N T M E C H A N I C A L P L A N M1.0 BASEMENT MECHANICAL PLAN SCALE: 1/8" = 1'-0" PLAN NOTES: 2 F 2 F 2 F 2 F UNIT 101 UNIT 102 UNIT 103 UNIT 104 UNIT 105 UNIT 106 UNIT 107 1 EF 1 EF 1 EF 1 EF 1 EF 1 EF 1 EF ELECTRONIC THERMOSTAT EQUIPMENT SYMBOLF 1 T INSULATED FLEXIBLE DUCT RECTANGULAR SUPPLY AND RETURN AIR DUCT TAKE-OFF TURNING VANES DUCT TRANSITION MECHANICAL LEGEND DESCRIPTIONSYMBOL CEILING SUPPLY REGISTER EXHAUST FAN CEILING MOUNTED CEILING RETURN AIR GRILLE COIL GAS FURNACE WITH DX COOLING S.P.E. 1 EF SYM.TYPE C.F.M. EXHAUST FAN SCHEDULE CONTROLCHAR.H.P.R.P.M.REMARKS CEILING MOUNTED 100 1/60.25 120/60/1 760 SEE ELEC. * SEE FLOOR PLANS FOR EXHAUST FANS TO HAVE 1 HR FIRE DAMPER AT GRILLE ELECTRIC HEATER SCHEDULE EH 1 SYM.TYPE SEMI-RECESSED WALL MTD 6824 BTU 2.0 KW 240/60/1 CHAR CONTROL INTEGRAL REMARKS QMARK MODEL GFR2004T2 WITH SEMI-RECESSED MOUNTING FRAME AIR KING FRAK 130 WITH 4"Ø DUCT & BACKDRAFT DAMPER, CEILING MOUNTED EXHAUST GRILLE AND WALL CAP. SYM.TYPE REMARKS FURNACE AND DX COOLING COIL SCHEDULE CHAR.MCASPE NATURAL GAS INPUT OUTPUT L.A.T.E.A.T.GAS TYPE LIQUID SUCTION C.D.NAT GAS INTAKE EXHAUST PIPING SIZESDX COOLING COIL B.T.U.E.A.T.L.A.T.C.F.M.MAX. P.D.SPEED @ ELEV. 1 F MOCP 2 F 3 F CONDENSING UNIT SCHEDULE 1 CU CHAR.SYM.BTU EAT MCA REMARKS 24,000 2 CU 95°F 17.5 3 CU 240/60/1 MOCP 30.0 LENNOX MODEL 13AXC-024 WITH 0°F LOW AMBIENT KIT UPFLOW LENNOX EL195UH045P24B WITH FULLY CASED R-410A DX COIL TO MATCH FURNACE AND HORIZ. VENT TERMINAL ASSEMBLY. UPFLOW 24,000 2"Ø2"Ø55°FNAT 3/4"34,44042,00044,000 1/3 65°F120/60/1 105°F0.6"800 75°F .25"55°FM-HIGH 3/4"NAH.P. C. UNIT SEE SCHED. C. UNIT SEE SCHED. UPFLOW SEE SEE LENNOX EL195UH090P48C WITH FULLY CASED R-410A DX COOLING COIL TO MATCH FURNACE & VERTICAL VENT TERMINAL ASSEMBLY. 48,000 3"Ø3"Ø55°FNAT 3/4"67,24082,00088,000 3/4 65°F120/60/1 105°F0.6"1600 75°F .25"55°FM-HIGH 3/4"NAH.P. C. UNIT SCHED. C. UNIT SCHED. 48,000 95°F 28.9240/60/1 50.0 LENNOX MODEL 13AXC-048 WITH 0°F LOW AMBIENT KIT 60,000 95°F 34.6240/60/1 60.0 LENNOX MODEL 13AXC-048 WITH 0°F LOW AMBIENT KIT SEE SEE LENNOX EL195UH110P60C WITH FULLY CASED R-410A DX COOLING COIL TO MATCH FURNACE & VERTICAL VENT TERMINAL ASSEMBLY. 60,000 3"Ø3"Ø55°FNAT 3/4"86,920106,000110,000 3/4 65°F120/60/1 105°F0.6"1995 75°F .25"55°FM-HIGH 3/4"NAH.P. C. UNIT SCHED. C. UNIT SCHED. * REF. LINE SIZES TO BE SIZED IN THE FIELD AS PER MFGR. INSTRUCTIONS FOR ACTUAL LENGTHS INSTALLED. SEE LARGE SCALE PLANS ON SHEETS M1.3 & M1.4 FOR TYPICAL DUCTWORK AND MECHANICAL EQUIPMENT LAY-OUT FOR INDIVIDUAL APARTMENT / TOWN HOME TYPES. SPECIAL NOTE:North THROWSYM.SIZE GRILLE AND REGISTER SCHEDULE CONSTR.CFM FINISH F.D.O.B.REMARKS SR-1 SR-2 R-1 ACCORD MODEL 222 WITH 2-WAY DEFLECTION. MOUNT IN SIDEWALL, REFER TO PLANS FOR HEIGHT. PROVIDE TRANSITION BOOT. A A PROVIDE TRANSITION BOOT BEHIND GRILLE AS REQUIRED TO CONNECT TO BRANCH DUCT. 12 x 4 100-199 STEEL WHITE NO YES2 WAY 24 x 10 700-900 STEEL WHITE NO NO---ACCORD MODEL 500. MOUNT IN SIDEWALL IN LOCATION SHOWN ON PLANS. CD-1 10 x 4 50-120 STEEL WHITE NO YES ACCORD MODEL 222 WITH 2-WAY DEFLECTION. MOUNT IN CEILING. PROVIDE TRANSITION BOOT.2 WAY FR-1 12 x 6 200-250 STEEL WHITE NO YES ACCORD FLOOR REGISTER WITH 2-WAY DEFLECTION. PROVIDE TRANSITION BOOT AS REQUIRED. 2 WAY TG-1 12x8 100-200 STEEL WHITE NO NO---ACCORD MODEL 500. MOUNT ABOVE DOOR HEADER AS SHOWN ON PLANS 10 x 4 50-125 STEEL WHITE NO YES2 WAY ACCORD MODEL 222 WITH 2-WAY DEFLECTION. MOUNT IN SIDEWALL, REFER TO PLANS FOR HEIGHT. PROVIDE TRANSITION BOOT. R-2 24 x 14 1600 STEEL WHITE NO NO---ACCORD MODEL 500. MOUNT IN SIDEWALL IN LOCATION SHOWN ON PLANS. R-3 18 x 36 1995 STEEL WHITE NO NO---ACCORD MODEL 500. MOUNT IN SIDEWALL IN LOCATION SHOWN ON PLANS. TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY A N E W P R O J E C T F O R MA D I S O N S Q U A R E A P A R T M E N T S AUG. - 2020 STAFF REXBURG, ID Engineered Systems Associates OCT. 19, 2020 1S T & 2 N D L E V E L M E C H . P L A N S M1.1 LEVEL 1 MECH. FLOOR PLAN SCALE: 1/8" = 1'-0" FA V PRV LEVEL 2 MECH. FLOOR PLAN SCALE: 1/8" = 1'-0" PLAN NOTES: 3 F UNIT 101 UNIT 102 UNIT 103 UNIT 104 UNIT 105 UNIT 106 UNIT 107 3 F UNIT 101 UNIT 201 UNIT 203 UNIT 104 UNIT 205 UNIT 206 UNIT 107 3 F 1 F 1 F 1 F 1 F 2 CU 1 CU 2 CU 1 CU 1 CU 3 CU 2 CU 1 CU 2 CU 1 CU 1 CU 1 CU 3 CU SEE LARGE SCALE PLANS ON SHEETS M1.3 & M1.4 FOR TYPICAL DUCTWORK AND MECHANICAL EQUIPMENT LAY-OUT FOR INDIVIDUAL APARTMENT / TOWN HOME TYPES. SPECIAL NOTE: 1 EF 1 EF 1 EF 1 EF 1 EF 1 EF 1 EF 1 EF 1 EF 1 EF 1 EF 1 EF 1 EF GAS METERS (SEE PLUMBING DWGS.) North North 1 EHFIRE RISER RM. 3 CU 1 CU 12 ' - 0 " 11'-0" 8' - 0 " 5'-0" 5'-0" 29 ' - 0 " 1 INSTALL CONDENSING UNITS ON 4" THICK CONCRETE PAD (BY GENERAL CONTRACTOR). SEE ARCH. DWGS. MECH. CONTRACTOR TO ROUTE REFR. LINE SETS FROM CONDENSING UNITS TO FURNACE DX COOLING COIL USING THE SHORTEST ROUTE POSSIBLE. FIELD VERIFY EXACT LENGTHS OF PIPING AND SIZE ACCORDING TO MFGR. SIZING INSTRUCTIONS. 2 1 1 1 1 2 2 2 2 2 2 2 1 EF W/ FD W/ FD W/ FD W/ FD TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY A N E W P R O J E C T F O R MA D I S O N S Q U A R E A P A R T M E N T S AUG. - 2020 STAFF REXBURG, ID Engineered Systems Associates OCT. 19, 2020 3R D L E V E L M E C H . F L O O R P L A N M1.2 LEVEL 3 MECH. FLOOR PLAN SCALE: 1/8" = 1'-0" PLAN NOTES: ATTIC SPACE UNIT 301 UNIT 303 UNIT 305 UNIT 306 1 F 1 F ATTIC SPACEATTIC SPACE 1 F 1 F SEE LARGE SCALE PLANS ON SHEETS M1.3 & M1.4 FOR TYPICAL DUCTWORK AND MECHANICAL EQUIPMENT LAY-OUT FOR INDIVIDUAL APARTMENT / TOWN HOME TYPES. SPECIAL NOTE: 1 EF 1 EF 1 EF 1 EF NO SCALE (DETAIL ONLY APPLIES TO TOP LEVEL TOWN HOMES) CONCENTRIC VENT TERMINATION DETAIL APPROX. 6" SCREW SLEEVE SECURELY TO 2x4 BRACING. SCREW HEAD TO BE INSTALLED INSIDE OF SLEEVE (TYPICAL OF 4) ROOF FLASHING ACCUMULATION 18" MINIMUM ABOVE AVERAGE SNOW INTAKE EXHAUST CLAMP SHEET METAL STRAP 20 GA GALVANIZED SLEEVE. ALLOW PIPING TO MOVE 20 GA GALVANIZED FREELY THRU SLEEVE INTAKEEXHAUST NO SCALE DRYER VENT DETAIL A FLOOR CEILING 4" HOSE CLAMP DRYER 4" FLEXIBLE DRYER VENT HOSE DRYER VENT HOSE A PLAN VIEW 4" FLEXIBLE DUCT UP IN WALL 4" HOSE CLAMP 4"Ø RISE 4"Ø DUCT UP IN WALL NOTE: 1- 2- NO PROJECTIONS SUCH AS SCREWS OF SHEET METAL CORNERS IN DUCTWORK OR AT ELBOWS ARE ALLOWED. MAXIMUM DUCT LENGTH IS 25'-0" INCLUDING 5'-0" REDUCTION FOR EACH 90Ø ELBOW. PROVIDE 4"Ø HOSE CONNECTION AT 4" AFF. EXTEND THRU WALL 2" MINIMUM FOR DRYER CONNECTION. PROVIDE MODEL DB425 "DRYERBOX" IN WALL WITH 4"Ø DUCT THRU ROOF. CONNECT 4"Ø FLEXIBLE DRYER VENT TO EXHAUST DUCT4" HOSE CLAMP RUN 4"Ø DUCT IN CEILING SPACE TO WALL CAP WALL CAP CEILING GRILLE CEILING EXHAUST FAN (SEE PLAN FOR SIZE) EXHAUST DUCT DAMPER BACK-DRAFT CABINET INSULATED FAN ASSEMBLY NO SCALE CEILING MOUNTED EXHAUST FAN DETAIL 1 HR. FIRE DAMPER North WHERE APPLICABLE (SEE FLOOR PLANS) ROOF SHINGLES AND SEAL WATERTIGHT FLASH INTO SHINGLES ROOF CAP (SLOPED ROOF) EXHAUST DUCT (SEE PLAN FOR SIZE) DAMPER BACK-DRAFT CEILING GRILLE CEILING EXHAUST FAN FAN ASSEMBLY CABINET INSULATED NO SCALE CEILING MOUNTED EXHAUST FAN DETAIL TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY A N E W P R O J E C T F O R MA D I S O N S Q U A R E A P A R T M E N T S AUG. - 2020 STAFF REXBURG, ID Engineered Systems Associates OCT. 19, 2020 LA R G E S C A L E M E C H A N I C A L P L A N S M1.3 LEVEL APT. MECHANICAL PLAN SCALE: 1/4" = 1'-0" APTS. 201,203,205,206,301,303,305 & 306 PLAN NOTES: 1 FIELD COORDINATE SPACE AVAILABLE FOR DUCTWORK. PROVIDE DUCT TRANSITIONS AS REQUIRED TO RUN DUCTS THRU STRUCTURE. UTILIZE JOIST SPACE WHERE POSSIBLE. PROVIDE AND INSTALL DRYER WALL BOX IN WALL. DRYER BOX TO BE COMPLETE WITH 4"Ø DUCT UP IN WALL TO WALL CAP. REFER TO DETAIL ON SHEET M1.2 FOR TYPICAL DRYER BOX INSTALLATION. NO FLEX DUCT ALLOWED. MOUNT PROGRAMMABLE THERMOSTAT ON WALL AND RUN 5 CONDUCTOR THERMOSTAT WIRE TO FURNACE & CONDENSING UNIT. INSTALL 4"Ø OUTSIDE AIR DUCT FROM 6x6 LOUVER ON EXTERIOR WALL TO MECH ROOM AS SHOWN. DROP THRU CEILING OF MECH. ROOM AND CONNECT TO RETURN AIR DUCT NEAR FLOOR. INSTALL HAND DAMPER IN 4"Ø DUCT AND BALANCE TO 75 CFM. RISE (2) 3"Ø FURNACE FLUES UP IN WALL TO VERTICAL VENT TERMINATION ASSEMBLY ON ROOF. SEAL ROOF PENETRATION WEATHERTIGHT. SEE DETAIL ON SHEET M1.2. PROVIDE AND INSTALL SHEET METAL BOOT UP TO FLOOR REGISTER ABOVE. RISE DUCT UP THRU CEILING INTO JOIST SPACE ABOVE AND RUN TO FLOOR REGISTER AS SHOWN. RISE 10x3 SA DUCT UP IN STUD SPACE OF WALL TO SERVE HIGH SIDEWALL SUPPLY REGISTER ON BATHROOM WALL ABOVE. RISE 14x3 SA DUCT UP IN STUD SPACE OF WALL TO SERVE HIGH SIDEWALL SUPPLY REGISTER ON WALL ABOVE. RISE 10x8 SA DUCT UP IN THICKENED WALL TO SERVE UPPER LEVEL SUPPLY REGISTERS IN LIVING ROOM 2 3 4 LARGE SCALE SINGLE 1 F BASEMENT MECHANICAL PLAN SCALE: 1/4" = 1'-0" APTS. 102,103,105,106 LARGE SCALE 2 LEVEL APT. LEVEL 1 MECHANICAL PLAN SCALE: 1/4" = 1'-0" APTS. 102,103,105,106 LARGE SCALE 2 LEVEL APT. 2 F BEDROOM MASTER BEDROOM W.I.C. BATH UTIL. KITCHEN LIVING ROOM ENTRY BEDROOM W.I.C. BATH UTIL. BEDROOM STOR. FAMILY ROOM STOR. STAIR UP STAIR DN. BEDROOM LAUNDRY W.I.C. MASTER BEDROOM KITCHEN LIVING ROOM ENTRY 1 EF 1 EF 1 EF WALL CAP (TYPICAL) 4" Ø E A 4" Ø E A WALL CAP (TYPICAL) 4" Ø E A 4" Ø E A WALL CAP (TYPICAL) 4" Ø E A 4" Ø E A BATH 4" Ø D R Y E R V E N T 4" Ø D R Y E R V E N T 1 1 1 1 1 1 1 1 1 1 1 1 2 2 T 3 T 3 F-2 F-1 TG-1(2) TG-1(2) TG-1(2) TG-1(2) TG-1(2) TG-1(2) R-1 16 x 1 0 R A 4" Ø O U T S I D E A I R D U C T HD 4 4 16 x 1 0 R A ( I N D R O P C L G . ) CD-1 60 CLG. FURR-DOWN SR-1 125 SR-1 1608"Ø SA 8"Ø SA 8" Ø S A SR-2 200 SR-2 255 10 x 8 S A ( I N F U R R - D O W N ) 10x8 SA 5 5 5 6"Ø 8"Ø SA IN FURR-DOWN 4" Ø O U T S I D E A I R D U C T SR-2 125 8"Ø SA 8"Ø SA (IN DROP CLG.) 8" Ø S A SR-2 160 4 R-216 x 1 4 R A FR-1 125 8" Ø S A I N J O I S T S P A C E 6 6 8" Ø S A I N J O I S T S P A C E 6 7 7 7 8" Ø S A FR-1 160 CD-1 60 6"Ø 20 x 1 0 S A ( I N D R O P C L G . ) SR-1 60 8 8 (6" BELOW CLG.) 8 16x10 RA (IN DROP CLG.) SR-2 200 9 9 9 SR-2 200 8"Ø SA IN FURR DOWN CLG. SR-2 200 TG-1(2) 6" Ø S A 8"Ø SA IN FURR DOWN CLG. CD-1 55 SR-2 255 10 x 8 S A ( I N F U R R - D O W N ) 8"Ø SA IN FURR-DOWN 10 1010 North North North 5 W/FD W/FD FURR-DOWN 8"Ø SA TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY A N E W P R O J E C T F O R MA D I S O N S Q U A R E A P A R T M E N T S AUG. - 2020 STAFF REXBURG, ID Engineered Systems Associates OCT. 19, 2020 LA R G E S C A L E M E C H A N I C A L P L A N S M1.4 BASEMENT LEVEL MECHANICAL PLAN SCALE: 1/4" = 1'-0" TOWN HOMES 101,104 & 107 PLAN NOTES: LARGE SCALE TOWN HOME LEVEL 1 MECHANICAL PLAN LARGE SCALE TOWN HOME LEVEL 2 MECHANICAL PLAN LARGE SCALE TOWN HOME 3 F BEDROOM BEDROOM KITCHEN STAIR UP STAIR W.I.C. W.I.C. BEDROOM FAMILY ROOM BATH LIVING ROOM 1/2 BATH UTIL. W.I.C. LAUNDRY ATTIC ACCESS 1 FIELD COORDINATE SPACE AVAILABLE FOR DUCTWORK. PROVIDE DUCT TRANSITIONS AS REQUIRED TO RUN DUCTS THRU STRUCTURE. UTILIZE JOIST SPACE WHERE POSSIBLE. PROVIDE AND INSTALL DRYER WALL BOX IN WALL. DRYER BOX TO BE COMPLETE WITH 4"Ø DUCT UP IN WALL TO ROOF CAP. REFER TO DETAIL ON SHEET M1.2 FOR TYPICAL DRYER BOX INSTALLATION. MOUNT PROGRAMMABLE THERMOSTAT ON WALL AND RUN 5 CONDUCTOR THERMOSTAT WIRE TO FURNACE. INSTALL 4"Ø OUTSIDE AIR DUCT FROM 6x6 LOUVER ON EXTERIOR WALL TO MECH ROOM AS SHOWN. DROP THRU CEILING OF MECH. ROOM AND CONNECT TO RETURN AIR DUCT NEAR FLOOR. INSTALL HAND DAMPER IN 4"Ø DUCT AND BALANCE TO 75 CFM. PROVIDE AND INSTALL SHEET METAL BOOT UP TO FLOOR REGISTER ABOVE. DROP 10x3 SA DUCT DOWN IN STUD SPACE OF WALL TO SERVE LOW SIDEWALL SUPPLY REGISTER BELOW. DROP 14x3 SA DUCT DOWN IN STUD SPACE OF WALL TO SERVE LOW SIDEWALL SUPPLY REGISTER BELOW. RISE 10x3 SA DUCT UP IN STUD SPACE OF WALL TO SERVE HIGH SIDEWALL SUPPLY REGISTER ON BATHROOM WALL ABOVE. RUN (2) 3"Ø FURNACE FLUES ACROSS CEILING OF UTILITY ROOM AND RISE UP IN CHASE ABOVE. RISE FLUES UP THRU ROOF TO VERTICAL VENT TERMINATION ASSEMBLY. SEAL ROOF PENETRATION WEATHERTIGHT. SEE DETAIL ON SHEET M1.2 2 3 4 T F-3 1 EF 4"Ø EA UP THRU FLOOR 1 EF 1 EF 1 EF 4" Ø E A 4"Ø EA THRU ROOF 4"Ø EA DN. THRU FLOOR WALL CAP (TYPICAL) 1 1 1 1 1 1 1 1 1 2 3 FR-1 125 FR-1 125 SR-1 60 (6" BELOW CLG.) SR-1 125 TG-1(2) TG-1(2)TG-1(2) TG-1(2) North North North SR-1 125 SR-1 50 R-3 18 x 1 6 R A (+6" A.F.F) FR-1 125 FR-1 125 SR-1 65 8x6 SA (IN FURR DOWN) CLG. FURR DOWN 8x 6 S A ( I N D R O P P E D C L G . ) 8x6 SA DN. IN CHASE 4" Ø E A (+6" A.F.F) (+6" A.F.F) (+6" A.F.F) 8x6 SA UP IN CHASE 18x16 SA AT CLG. 12x8 SA DN. THRU FLOOR12x8 SA UP THRU FLOOR ABOVE SR-1 180 SR-1 180 12x8 SA (IN DROPPED CLG.) 8x6 SA (IN FURR DOWN) CD-1 50 16 x 1 0 S A I N D R O P P E D C L G . 6"Ø 10 x 8 S A 4"Ø OUTSIDE AIR DUCT (IN FURR DOWN) 4 CLG. FURR DOWN SR-1 130 SR-1 130 8"Ø 8"Ø 14 x 1 0 S A ( I N F U R R D O W N ) 14 x 1 0 S A ( I N F U R R D O W N ) SR-2 200 SR-2 200 4 5 5 5 8 5 5 6 6 7 7 7 7 7 6 88 99 9 1 SCALE: 1/4" = 1'-0" TOWN HOMES 101,104 & 107 SCALE: 1/4" = 1'-0" TOWN HOMES 101,104 & 107 BEDROOM TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY A N E W P R O J E C T F O R MA D I S O N S Q U A R E A P A R T M E N T S AUG. - 2020 STAFF REXBURG, ID Engineered Systems Associates OCT. 19, 2020 FO U N D A T I O N P L U M B I N G P L A N P1.0FOUNDATION PLUMBING PLAN SCALE: 1/8" = 1'-0" BALL TYPE ISOLATION VALVE PIPE RISE PIPE DROP SYMBOL CO WCO COTG VTR V VENT VENT THRU ROOF CLEANOUT WALL CLEANOUT CLEANOUT TO GRADE DESCRIPTION PLUMBING LEGEND SOIL OR WASTE PIPING VENT LINE PIPING GAS PIPINGG DOMESTIC HOT WATER PIPING DOMESTIC COLD WATER PIPING CONDENSATE DRAIN PIPINGCD BASEMENT PLUMBING PLAN North SCALE: 1/8" = 1'-0" PLAN NOTES: 1 SEE CIVIL SITE PLAN FOR CONTINUATION OF 4" SEWER MAIN. SEE CIVIL SITE PLAN FOR CONTINUATION OF 4" FIRE LINE. 4" VENT STACK UP. SEE BASEMENT PLUMBING FLOOR PLAN ON THIS SHEET FOR CONTINUATION OF PIPING. 4" WASTE STACK UP. SEE BASEMENT PLUMBING FLOOR PLAN ON THIS SHEET FOR CONTINUATION OF PIPING. SEE CIVIL SITE PLAN FOR CONTINUATION OF 2" DOMESTIC CW LINE. RISE 2" DOMESTIC COLD WATER UP THRU SLAB INTO RISER ROOM TO SERVE WATER PRESSURE REDUCING VALVE ASSEMBLY. SEE SHEET P1.1 FOR RISER LOCATION ABOVE. 4" FIRE LINE UP THRU SLAB FLOOR TO FIRE RISER IN ROOM. SEE DETAIL ON SHEET P2.0 FOR RISER INFORMATION. INSTALL COMPLETE FIRE SPRINKLER SYSTEM FOR ALL LEVELS OF APTS. AS PER NFPA 13R REQUIREMENTS. 3" WASTE UP IN WALL ABOVE. SEE BASEMENT PLUMBING PLAN ON THIS SHEET FOR CONT. OF PIPING. RISE 1-1/4" LAWN SPRINKLER LINE UP THRU SLAB INTO RISER ROOM TO WATER PRESSURE REDUCING VALVE ASSEMBLY. SEE SHEET P1.1 FOR RISER LOCATION ABOVE. RISE 1" CW MAIN SERVING TOWN HOME UP IN WALL TO MECH. ROOM ABOVE. SEE SHEET P1.1 FOR CONT. OF PIPING. DROP 1" CW LINE DOWN IN WALL TO SERVE (2) LEVEL APT. AND RISE (2) 3/4" CW LINES UP IN WALL TO SERVE SINGLE LEVEL APTS. ABOVE. SEE SHEET P1.1 FOR CONT. OF PIPING. RISE (3) 1" CW MAIN LINES AND (4) 1-1/4" CW MAIN LINES UP THRU SLAB INTO RISER ROOM. REFER TO PRESSURE REDUCING VALVE DETAIL ON SHEET P2.0 FOR INDIVIDUAL WATER METERS LOCATED IN RISER ROOM. RISE 14 TOTAL GAS LINES (8) 3/4" & (6) 1" LINES UP TO METER TREE ABOVE GRADE. SEE SHEET P1.1 FOR METER LOCATIONS. RISE (2) 3/4" GAS LINES UP IN WALL TO SERVE SINGLE LEVEL APTS. ABOVE. SEE SHEET P101 FOR CONT. OF GAS PIPING. RISE 1" GAS LINE UP IN WALL TO SERVE TOWN HOME FURNACE ABOVE. SEE SHEET P101 FOR CONTINUATION OF GAS PIPING. CONNECT 1" (OZ.) GAS LINE TO FURNACE COMPLETE WITH SHUT-OFF VALVE, FLEXIBLE CONNECTION AND DIRT LEG. SEAL FOUNDATION WALL PENETRATION WEATHERTIGHT ALL AROUND PIPING. 2 3 4 5 6 7 8 8 88 8 88 8 8 8 8 8 8 8 8 T-1 WC-1 L-1 FD-1 WH-1 2 F WC-1L-1 T- 1 FD-12 F WC-1 L-1T- 1 WC-1 T-1 L-1 FD-1 WH-1 2 F WC-1L-1 T- 1 WC-1 L-1T- 1 FD-1 WH-1 2 F L-1 WC-1 T-1 34 3 4 34 3 4 34 3 4 UNIT 101 UNIT 102 UNIT 103 UNIT 104 UNIT 105 UNIT 106 UNIT 107 3 3 4 4 9 9 9 9 9 9 9 3 3 4 4 3 4 SEE SHEETS P1.3 & P1.4 FOR PIPING SERVING INDIVIDUAL APT. / TOWN HOMES. SPECIAL NOTE: 4" T-1 WC-1 2" V. L-1 2" V. 2" V. 2"2" 4" 3 4T-1 WC-1 2" V. FD-1 FD-1 T-1 WC-1 2" V. L-1 L-1 L-1 2" V . T-1WC-1 L-1 WC-1 4" North 4"4"4"4"2" 4" 4" 4" 4" 4" 5 2 7 6 2" DOMESTIC CW 4" FIRE LINE 2" V. UP FS-1 4" 2" V. UP 10 10 1 3" 4" 4" 4" 1 4" COTG INV. ELEV. -23" BELOW SLAB 4" 4" COTG INV. ELEV. -23" BELOW SLAB 1 4" 4" 4" COTG INV. ELEV. -23" BELOW SLAB 1 4" 2" V . 4" COTG INV. ELEV. -23" BELOW SLAB 3" 34 3 4 2" V. 2" V. 2"2" FD-1 FD-1 L-1 2" V . T-1WC-1 L-1 WC-1 4"4"4"2"4" 4" COTG INV. ELEV. -23" BELOW SLAB 1 4" 4" 4" COTG INV. ELEV. -23" BELOW SLAB 1 4" 2" V . 4" 1 4" COTG INV. ELEV. -23" BELOW SLAB 4" 3" 4" WH-1 1-1/4" LAWN SPRINKLER 1" (IN JOIST SPACE) DROP 1" (UNDERGROUND) 11 11 11 1" (IN JOIST SPACE) DROP DROPDROP DROP DROP DROP 1" (IN JOIST SPACE) 11 1" (UNDERGROUND) 1-1/4" (IN JOIST SPACE) 1-1/4" (IN JOIST SPACE) 1-1/4" (IN JOIST SPACE) 1-1/4" (IN JOIST SPACE) 12 12 12 12 12 1-1/4" (UNDERGROUND) 1" (UNDERGROUND) (2) 1-1/4" (UNDERGROUND) 1" (UNDERGROUND) (2) 1-1/4" (UNDERGROUND) (2) 1" (UNDERGROUND) (3) 1-1/4" (UNDERGROUND) (2) 1" (UNDERGROUND) (4) 1-1/4" (UNDERGROUND) (2) 1" (UNDERGROUND) 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1" (UNDERGROUND) 13 13 G G G G G G G G G G G G G G 14 14 (6) 1" GAS LINES UNDERGROUND (8) 3/4" GAS LINES & (5) 1" GAS LINES UNDERGROUND (6) 3/4" GAS LINES & (1) 1" (2) 3/4" (1) 1" (2) 3/4" (4) 1" GAS LINES UNDERGROUND (4) 3/4" GAS LINES & (1) 1" (2) 3/4" (2) 1" GAS LINES UNDERGROUND (2) 3/4" GAS LINES & (1) 1" (2) 3/4" 1" (IN JOIST SPACE) 1" (IN JOIST SPACE) G G 1" (IN JOIST SPACE) 1" (IN JOIST SPACE) (1) 1" (2) 1" GAS LINES UNDERGROUND (2) 3/4" GAS LINES & (1) 1" GAS LINES UNDERGROUND 15 15 15 15 15 16 16 16 17 17 17 17 17 18 18 18(TYP.)18 (TYP.)18 (TYP.)18(TYP.) 18 1818 (1) 1" (2) 3/4" (1) 1" (2) 3/4" (1) 1" (2) 3/4" (1) 1" (2) 3/4" TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY A N E W P R O J E C T F O R MA D I S O N S Q U A R E A P A R T M E N T S AUG. - 2020 STAFF REXBURG, ID Engineered Systems Associates OCT. 19, 2020 1S T & 2 N D L E V E L P L U M B I N G P L A N S P1.1 LEVEL 1 PLUMBING PLAN SCALE: 1/8" = 1'-0" FA V PRV LEVEL 2 PLUMBING PLAN SCALE: 1/8" = 1'-0" PLAN NOTES: 1 2" WATER RISER ASSEMBLY FOR ENTIRE BUILDING CW SERVICE. PROVIDE MANIFOLD WITH (15) INDIVIDUAL SHUT-OFF VALVES FOR EACH TOWN HOME / APT. SEE DETAIL ON SHEET P2.0 4" FIRE RISER ASSEMBLY. SEE DETAIL ON SHEET P2.0 FOR RISER INFORMATION. INSTALL COMPLETE FIRE SPRINKLER SYSTEM FOR ALL LEVELS OF APTS. AS PER NFPA 13R REQUIREMENTS. GAS METER TREES (1) 12 METER TREE & (1) 3 METER TREE (15 METERS TOTAL). SIZE OF GAS METERS TO MATCH LOADS OF INDIVIDUAL APT. GAS LOADS FOR FURNACE. SEE MECH. SCHEDULE FOR BTU INFORMATION. DELIVERY PRESSURE TO BE IN OUNCES. SEE LARGE SCALE PLANS ON SHEETS P1.3 & P1.4 FOR PIPING TO FURNACES. CONNECT 2" VENT SERVING FLOOR SINK TO NEAREST APARTMENT VENT SYSTEM LINE THAT IS 2" OR LARGER. CONNECT 3/4" CW LINE TO NEAREST 3/4" OR LARGER CW LINE SERVING ADJACENT TOWN HOME / APT. 1" CW MAIN FOR TOWN HOME. SEE LARGE SCALE PLUMBING PLANS ON SHEETS P1.3 FOR CONTINUATION OF PIPING SERVING TOWN HOME FIXTURES. CONNECT 1" (OZ.) GAS LINE TO FURNACE COMPLETE WITH SHUT-OFF VALVE, FLEXIBLE CONNECTION AND DIRT LEG. CONNECT 3/4" GAS LINE TO FURNACE COMPLETE WITH SHUT-OFF VALVE, FLEXIBLE CONNECTION AND DIRT LEG. RISE (2) 3/4" GAS LINES UP IN WALL TO SERVE (2) LEVELS OF APTS. ABOVE. 3/4" GAS LINE UP IN WALL TO SERVE LEVEL 3 APT. ABOVE. SEE SHEET P1.2 FOR CONT. OF PIPING CONNECTING TO FURNACE. RISE (2) 3/4" CW MAIN LINES UP IN WALL TO SERVE (2) LEVELS OF APTS. ABOVE. 3/4" CW MAIN TO SERVE APT. ON THIS LEVEL. SEE LARGE SCALE PLUMBING PLANS ON SHEET P1.4 FOR CW PIPING SERVING APT. FIXTURES. RISE 3/4" CW MAIN UP TO SERVE LEVEL 3 APT. ABOVE. SEE SHEET P1.2 FOR CONT. OF PIPING. REFER TO SHEET P1.0 FOR DOMESTIC CW LINES RUNNING UNDERGROUND TO SERVE EACH TOWN HOME AND APT. DROP 14 TOTAL GAS LINES (8) 3/4" & (6) 1" LINES UNDERGROUND TO SERVE EACH TOWN HOME AND APT. REFER TO SHEET P1.0 FOR PIPING. 4" VENT STACK UP. 4" WASTE STACK UP. 2 3 4 5 3 33 3 33 3 3 3 3 3 3 WC-1 L-1 WH-1 3 F WC-1 L-1 T- 1 WC-1 L-1T- 1 WC-1 L-1 WC-1 L-1 17 18 UNIT 101 UNIT 102 UNIT 103 UNIT 104 UNIT 105 UNIT 106 UNIT 107 FD-1 DW-1 KS-1 RB-1 WB-1 DW-1 KS-1 17 18 DW-1 KS-1 RB-1 RB-1 WB-1 RB-1 WC-1 L-1 WH-1 3 F FD-1 DW-1KS-1 17 18 WB-1 DW-1 KS-1 17 18 DW-1 KS-1 RB-1 RB-1 WB-1 RB-1 WC-1 L-1 WH-1 FD-1 DW-1KS-1 UNIT 101 UNIT 201 UNIT 203 UNIT 104 UNIT 205 UNIT 206 UNIT 107 3 F 3333 WC-1L-1 T- 1 WC-1 L-1T- 1 WC-1L-1 WC-1 L-1 17 18DW-1 KS-1 17 18 DW-1 KS-1 RB-1 RB-1 17 18DW-1 KS-1 17 18 DW-1 KS-1 RB-1 RB-1 L-1 WC-1 T-1 WB-1 L-1 WC-1 T-1 WB-1 WH-1 FD-1 1 F WB-1 WH-1 FD-1 1 F 3 3 L-1 WC-1 T-1 WB-1 L-1 WC-1 T-1 3 3 WB-1 WH-1 1 F WB-1 WH-1 FD-1 1 F L-1 WC-1 T-1 WB-1 L-1 WC-1 T-1 3 3 HB-1 6 6 HB-1 6 HB-1 6 3/4" SEE SHEETS P1.3 & P1.4 FOR PIPING SERVING INDIVIDUAL APT. / TOWN HOMES. SPECIAL NOTE: HB-1 6 3/4" 2 1 4 7 7 7 7 8 8 8 8 9 9 9 9 9 10 10 10 10 10 11 11 11 11 11 12 12 12 13 13 13 13 14 14 14 14 14 15 16 16 12 METER GAS TREE 3 METER GAS TREE 4 5 FS-1 17 18 FD-1 13 FIRE RISER RM. North North 12 12 T- 1 T- 1 T- 1 T- 1 1" GAS TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY A N E W P R O J E C T F O R MA D I S O N S Q U A R E A P A R T M E N T S AUG. - 2020 STAFF REXBURG, ID Engineered Systems Associates OCT. 19, 2020 3R D L E V E L P L U M B I N G P L A N P1.2 LEVEL 3 PLUMBING PLAN SCALE: 1/8" = 1'-0" PLAN NOTES: 1 INSTALL COMPLETE FIRE SPRINKLER SYSTEM FOR ALL LEVELS OF APTS. AS PER NFPA 13R REQUIREMENTS. CONNECT 3/4" GAS LINE TO FURNACE COMPLETE WITH SHUT-OFF VALVE, FLEXIBLE CONNECTION AND DIRT LEG. 3/4" CW MAIN TO SERVE APT. ON THIS LEVEL. SEE LARGE SCALE PLUMBING PLANS ON SHEET P1.4 FOR CW PIPING SERVING APT. FIXTURES. 4" VENT THRU ROOF. 2 3 ATTIC SPACE UNIT 301 UNIT 303 UNIT 305 UNIT 306 1111 WC-1L-1 T- 1 WC-1 L-1T- 1 WC-1L-1 WC-1 L-1 4DW-1 KS-1 4 DW-1 KS-1 RB-1 RB-1 4DW-1 KS-1 4 DW-1 KS-1 RB-1 RB-1 WB-1 WH-1 FD-1 1 F WB-1 WH-1 FD-1 1 F WB-1 WB-1 SEE SHEETS P1.3 & P1.4 FOR PIPING SERVING INDIVIDUAL APT. / TOWN HOMES. SPECIAL NOTE: 2 2 3 3 ATTIC SPACEATTIC SPACE DROP WH-1 FD-1 1 F 2 3 DROP WH-1 FD-1 1 F 2 3 DROP DROP 4 T- 1 T- 1 4 4 4" V. DN IN CHASE 4 4" V. DN IN CHASE North TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY A N E W P R O J E C T F O R MA D I S O N S Q U A R E A P A R T M E N T S AUG. - 2020 STAFF REXBURG, ID Engineered Systems Associates OCT. 19, 2020 LA R G E S C A L E P L U M B I N G P L A N S P1.3 LEVEL APT. PLUMBING PLAN PLAN NOTES: 1 4" WASTE STACK UP IN WALL. 4" VENT STACK UP IN WALL. RUN 3/4" CONDENSATE DRAIN LINE FROM FURNACE AND DX COOING COIL TO FLOOR DRAIN IN MECH. ROOM AND TERMINATE WITH 90° DOWNTURNED ELBOW WITH AIRGAP. CONNECT 3/4" GAS LINE TO FURNACE COMPLETE WITH SHUT-OFF VALVE, FLEXIBLE CONNECTION AND DIRT LEG. SEE DETAIL ON SHEET P2.0. INSTALL BALL TYPE SHUT OFF VALVE BELOW CEILING OF MECH. ROOM IN ACCESSIBLE LOCATION FOR 3/4" CW SERVING APT. CONNECT 1" GAS LINE TO FURNACE COMPLETE WITH SHUT-OFF VALVE, FLEXIBLE CONNECTION AND DIRT LEG. SEE DETAIL ON SHEET P2.0. INSTALL BALL TYPE SHUT OFF VALVE BELOW CEILING OF MECH. ROOM IN ACCESSIBLE LOCATION FOR 1" CW SERVING APT. 2 3 4 LARGE SCALE SINGLE 1 F FD - 1 WH-1 WB-1 WC-1 L-1 T-1 DW-1 KS-1 RB-1 BASEMENT PLUMBING PLAN LARGE SCALE 2 LEVEL APT. LEVEL 1 PLUMBING PLAN LARGE SCALE 2 LEVEL APT. WC-1 L-1 T-1 2 F FD - 1 WH-1 WB-1 WB-1 (ABOVE) SEE SHEET P1.0 FOR WASTE PIPING SERVING BASEMENT LEVEL FIXTURES. ALL WASTE PIPING SHOWN ON THIS PLAN SERVES 2ND LEVEL FIXTURES ABOVE. NOTE: WC-1 L-1 T-1 DW-1 KS-1 RB-1 RB-1 (ABOVE) L-1 (ABOVE) (ABOVE) WC-1 T-1 (ABOVE) 2 1 21 21 KS-1 (ABOVE) 3 3 4 3/4" GAS ALL WATER PIPING FOR SINGLE LEVEL APTS. TO BE RUN ABOVE CEILING FOR 2ND LEVEL APTS. AND BETWEEN 2ND AND 3RD LEVELS FOR 3RD LEVEL APT. NO WATER PIPING ALLOWED IN COLD ATTIC SPACE. NOTE: 5 5 2" V. 3/4" 2" 3/4" 3/4" 2" 2" 1/2" 3/4"1/2" 2" 2" 1/2" 3" 2"2" BEDROOM MASTER BEDROOM W.I.C. BATH UTIL. KITCHEN LIVING ROOM ENTRY BEDROOM W.I.C. BATHUTIL. BEDROOM STOR. FAMILY ROOM STOR. STAIR UP STAIR DN. BEDROOM LAUNDRY W.I.C. MASTER BEDROOM KITCHEN LIVING ROOM ENTRY 6 6 1" GAS 7 7 3/4" 2"1" 3/4" 2"3/4" 1" 2" 2"2" 2"2"2" 2" 3"2" 2" 2" V. 1" 2"2" 2" 2"2"2" 1/2" North North North SCALE: 1/4" = 1'-0" APTS. 201,203,205,206,301,303,305 & 306 SCALE: 1/4" = 1'-0" APTS. 102,103,105,106 SCALE: 1/4" = 1'-0" APTS. 102,103,105,106 TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY A N E W P R O J E C T F O R MA D I S O N S Q U A R E A P A R T M E N T S AUG. - 2020 STAFF REXBURG, ID Engineered Systems Associates OCT. 19, 2020 LA R G E S C A L E P L U M B I N G P L A N S P1.4 BASEMENT LEVEL PLUMBING PLAN PLAN NOTES: 1 4" WASTE STACK UP IN WALL. 4" VENT STACK UP IN WALL. RUN 3/4" CONDENSATE DRAIN LINE FROM FURNACE AND DX COOING COIL TO FLOOR DRAIN IN MECH. ROOM AND TERMINATE WITH 90° DOWNTURNED ELBOW WITH AIRGAP. CONNECT 1" GAS LINE TO FURNACE COMPLETE WITH SHUT-OFF VALVE, FLEXIBLE CONNECTION AND DIRT LEG. SEE DETAIL ON SHEET P2.0. INSTALL BALL TYPE SHUT OFF VALVE BELOW CEILING OF MECH. ROOM IN ACCESSIBLE LOCATION FOR 1" CW SERVING APT. 2 3 4 LARGE SCALE TOWN HOME SEE SHEET P1.0 FOR WASTE PIPING SERVING BASEMENT LEVEL FIXTURES. ALL WASTE PIPING SHOWN ON THIS PLAN SERVES 2ND LEVEL FIXTURES ABOVE. NOTE: 5 LEVEL 1 PLUMBING PLAN LARGE SCALE TOWN HOME LEVEL 2 PLUMBING PLAN LARGE SCALE TOWN HOME NO WATER PIPING ALLOWED IN COLD ATTIC SPACE. ALL 2ND LEVEL FIXTURES TO BE SERVED FROM BELOW. SEE LEVEL 1 LARGE SCALE TOWN HOME PLUMBING PLAN ON THIS SHEET. NOTE: 4" V. DOWN EXPOSED ON WALL 4" V. UP 4" VTR 1 2 3" WASTE DN. IN WALL 3" WASTE UP IN WALL 1/2" HW UP IN WALL 3/4" CW UP IN WALL 3/4" CW DN. IN WALL 1/2" HW DN. IN WALL 3 3 F WH-1 FD-1 4 1" GAS 5 2" V. WC-1 (ABOVE) 2" V. T-1 (ABOVE) 2" V. 1/2" 2" 3/4" 3/4" 3/4" 2" 2" WB-1 (ABOVE) 3/4" 1/2" 1/2"2" 3/4"2" L-1 (ABOVE) WC-1 (ABOVE) 2" V. 1/2" 2"3" 3" 3" DN IN WALL 1/2" T-1 (ABOVE) 2" V. L-1 (ABOVE)1/2" 1-1/2" 1/2" DN. IN WALL1/2" UP IN WALL KS-1 DW-1KS-1 (ABOVE) 2" V. UP 3/4" 3/4" 1/2" 2" 2" 2" WC-1 L-1 L-1 L-1 WC-1 T-1 T-1 T-1 WC-1 L-1 WC-1 FD-1 (ABOVE) 2" V. WC-1 (ABOVE) 2" V. L-1 (ABOVE) 2"2"1/2" 3" 3" 1/2" 1/2" 1/2" 2"3" 1/2" 1/2" 2" V. 1/2" 2" V. 1-1/2" 2"2"2" 2" 2" 2" 2" 3" 2" 2" 3" WB-1 BEDROOM BEDROOM KITCHEN STAIR UP STAIR W.I.C. W.I.C. BEDROOM FAMILY ROOM BATH LIVING ROOM 1/2 BATH UTIL. W.I.C. LAUNDRY ATTIC ACCESS North North North BEDROOM SCALE: 1/4" = 1'-0" TOWN HOMES 101,104 & 107 SCALE: 1/4" = 1'-0" TOWN HOMES 101,104 & 107 SCALE: 1/4" = 1'-0" TOWN HOMES 101,104 & 107 TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY A N E W P R O J E C T F O R MA D I S O N S Q U A R E A P A R T M E N T S AUG. - 2020 STAFF REXBURG, ID Engineered Systems Associates OCT. 19, 2020 PL U M B I N G D E T A I L S & S C H E D U L E S P2.0 TRAP 1-1/2"LAVATORY WATER CLOSET FLOOR DRAIN L-1 FD-1 SYM. WC-1 DESCRIPTION PLUMBING FIXTURE SCHEDULE 1-1/2" 2" 1-1/2" 2"2"- 1/2" - 1/2" PIPE SIZE 2" VENTWASTE INT.3" C.W. 1/2" H.W. - WITH DEEP SEAL P-TRAP COUNTERTOP MOUNT FLUSH TANK (RESIDENTIAL) REMARKS WATER HEATERWH-1 ---3/4"3/4" 50 GALLON ELEC. WATER HEATER WITH T&P VALVE & EXP. TANK. 4500 WATT ELEMENTS NON-SIMULTANEOUS AT 240/60/1 POWER -DISHWASHERDW-1 -3/4"-1/2"UNDER COUNTER - CONNECT TO ADJACENT SINK 1-1/2"TUB / SHOWERT-1 1-1/2"1-1/2"1/2"1/2" 1-1/2"KITCHEN SINKKS-1 1-1/2"1-1/2"1/2"1/2"S.S. COUNTERTOP DOUBLE COMPARTMENT SINK WITH DISPOSER 4" 1" 4" 2" 4" 4"20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 SHUT-OFF VALVE WITH TAMPER SWITCH ANCHOR AT FLOOR OR WALL PENETRATION MAIN DRAIN ALARM TEST VALVE MAIN DRAIN VALVE WET PIPE ALARM VALVE 2" SPACE - CAULK WATER-TIGHT THRUST BLOCK ELECTRIC BELL FLOW ALARM SWITCH DOUBLE CHECK (ASSE1015) BLDG. EXTERIOR WALL PRESSURE GAUGE (2 REQ'D) PRESSURE SWITCH SPLASH BLOCK RETARDING CHAMBER SIAMESE F.D. CONNECTION BALL DRIP RETARDING CHAMBER DRAIN CHECK VALVE ITEM DESCRIPTION NO SCALE FIRE SPRINKLER RISER & VALVE DETAIL 6 4 9 3 1 2 18 16 15 10 11 8 12 5 7 1 17 20 19 14 13 20 * * * * * SEE ELECTRICAL PLANS FOR CONNECTION TO ELECTRICAL DEVICE. COORDINATE WITH ELECTRICAL CONTRACTOR. ALL PIPING THIS DETAIL TO BE INSTALLED BY FIRE SPRINKLER CONTRACTOR UNLESS NOTED.FROM CITY WATER SYSTEM GRADE FLOOR 4" TO SPRINKLER SYSTEM RIGHT OR LEFT HAND AS PER FLOOR PLAN 6" V E R T I C A L 18" MAX. DRIP LEG SAME SIZE AS DROP GAS LINE CONNECTION DETAIL NO SCALE GROUND JOINT MANUAL MAIN SHUT-OFF VALVE GAS FURNACE FLEXIBLE GAS CONNECTOR. UNION 3/4" MAIN. SEE DROP FROM PLAN FOR SIZE WASHER BOX PIPING DETAIL NO SCALE 42 " T O 2" WASTE LINE 2" VENT LINE UP 1/2" HOT WATER LINE 1/2" COLD WATER LINE STUD WALL AT 16" O.C. 2x4 WOOD HEADER ABOVE UTILITY BOX FINISHED FLOOR DROP 2" WASTE LINE DOWN BELOW FLOOR SHUT-OFF VALVES 2" P-TRAP FL O O R WASHER BOXWB-1 2"2"2"1/2"1/2"POLY WASHER BOX WITH 1/2" HW AND CW STOP VALVES 2" STANDPIPE WITH P-TRAP (SEE DETAIL THIS SHEET) FLOOR DRAIN IN CONCRETE FLOOR 2" WASTE LINE TO WASTE AND VENT NO SCALE SYSTEM 2" DEEP SEAL P-TRAP TO FINISH FLOOR LEVEL STRAINER ADJUST FLOOR DRAIN BODY TILE AND GROUT CONCRETE FLOOR CLEAN OUT DETAILS NO SCALE CLEANOUT TO GRADE (COTG) WASTE LINE FINISH GRADE 1'-0" WALL CLEANOUT (WCO) 1/8 C.I. BEND FLOOR LINE WALL BRASS CLEANOUT PLUG WITH COUNTER SUNK HEAD 16" SQUARE CONC PAD TROWEL SMOOTH 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE. CAST IRON WASTE LINE. LENGTH TO SUIT. CHROME WALL COVER AND SCREW MAY EXTEND AS A WASTE OR VENT PLUGGED TEE WITH CLEANOUT BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. 1/8 CAST IRON BEND NO SCALE WATER HEATER PIPING DIAGRAM UNION (TYP) BALL VALVE (TYP) WATER HEATER HEAT TRAP FITTING COLD WATER LINE HOT WATER LINE PIPE FULL SIZE TO FLOOR DRAIN ASME T&P RELIEF VALVE SEISMIC BRACING STRAPS ANCHORED TO WALL 2" DEEP DRAIN PAN UNDER HEATER DRAIN VALVE WITH THREADED HOSE CONNECT. COLD WATER INLET FLOOR SINKFS-1 2"4"4"--WITH DEEP SEAL P-TRAP AND 3/4 GRATE EXTERIOR HOSE BIBBHB-1 ---3/4"-FREEZEPROOF EXTERIOR HOSE BIBB WITH REMOVABLE KEY. LENGTH TO SUIT WALL THICKENESS REFR. SUPPLY BOXRB-1 ---1/2"-RECESSED REFRIGERATOR WATER SUPPLY BOX WITH 3/8" SHUT-OFF VALVE. (TYPICAL) BALL VALVE DIRT LEG TYP. UNION 3/4" DRAIN VALVE 5'-0" CONTRACTOR BY PLUMBING CONTRACTOR BY SITE UTILITIES CAP GRADE EXT WALL 36" NO SCALE WATER PRESSURE REDUCING STATION DETAIL COMBINATION PRESSURE REDUCING VALVE AND STRAINER. SET DISCHARGE AT 50 PSIG TRERICE 3-1/2" NO. 800, RANGE 0-TO-100 PSI 1'-0" MINIMUM CLEARANCE DOUBLE CHECK VALVE ASSEMBLY DRAIN VALVE 1-1/4" CW LINE OUT FOR SPRINKLER SYSTEM 2" WATER SUPPLY TO BUILDING DOUBLE CHECK VALVE BACKFLOW PREVENTER WITH BALL VALVES AND STRAINER 7 TOTAL CW LINES (3) 1" & (4) 1-1/4" LINES HOUSE WATER METER AS REQ'D BY CITY OF REXBURG REMOTE READOUT DEVICE FOR METER NO SCALE PIPING IN OUTSIDE WALL DETAIL VENT PIPING FINISHED WALL 1/2" COLD WATER 1/2" HOT WATER RUN BUILDING VAPOR BARRIER ON OUTSIDE OF PIPING. STUD SPACE WITH BATT INSULATION 1-1/2" RIGID INSULATION EXTERIOR WALL FINISH AS INDICATED ON DRAWINGS. TYPICAL PLUMBING FIXTURE FLOOR DRAIN IN WOOD FLOOR DETAIL EACH SIDE OF DRAIN LINE 2x4 SUPPORT MEMBERS ON WOOD SUBFLOOR MEMBER JOIST HANGER NEW 2x8 CROSS SEAL PIPE PENETRATION2" WASTE LINE TO WASTE AND VENT FLOOR JOISTS NO SCALE SYSTEM 2" DEEP SEAL P-TRAP WATER TIGHT. UNDER METAL PAN. NEW 20 GA GALVANIZED SHEET METAL PAN. SOLDER TO FINISH FLOOR LEVEL STRAINER ADJUST WATERTIGHT. FLOOR DRAIN BODY TILE AND GROUT FILL PAN WITH GROUT (1) FOR EACH TOWER 7 INDIVIDUAL WATER METERS (TYPICAL) BALL VALVE 2" CW MAIN RUNNING UNDERGROUND AT A MINIMUM DEPTH OF 4'-0" SEE SHEET P1.0 FOR ROUTING OF LINES. NO JOINTS ALLOWED UNDERSLAB OR UNDERGROUND TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY MA D I S O N S Q U A R E 05-2020 STAFF P.E. JOB #2020 Pocatello, Idaho 83201 1823 E. Center tel (208) 232-4439 www.payneengineeringinc.com REXBURG, ID AP A R T M E N T S RECEPTACLE MOUNTING DETAIL NO SCALE TO SUIT WALL RAISED RING CONDUIT(S) ENTRANCE 4'' SQUARE BOX BACK OF COVER W/FELT-TIP MARKER TO BE AS PER SPECIFICATIONS. COVER PLATES - STYLE & COLOR CIRCUIT NUMBER TO BE WRITTEN ON NORMAL POWER COLOR - (SEE SPECS) RECEPTACLE - 15 OR 20 AMP RATED - SEE SPECIFICATIONS. GROUND CONDUCTOR GREEN INSULATED DUPLEX RECEPTACLE WALL MOUNTED FIXTURE CEILING MOUNTED FIXTURE FLUORESCENT FIXTURE ELECTRICAL SYMBOL SCHEDULE BRANCH CIRCUIT - HOME-RUN TO PANEL BRANCH CIRCUIT - IN FLOOR OR UNDERGROUND MECHANICAL EQUIPMENT OR DETAIL SYMBOL DRAWING NOTE (ON THE SHEET WHERE SHOWN) THERMOSTAT W/ 3/4"CONDUIT W/PULL CORD TO MECH. UNIT FAN MOTOR CONNECTION POINT BRANCH CIRCUIT - CONCEALED * SEE MECHANICAL DRAWINGS FOR CONDUIT DESTINATION AND M.C. V.I.F. A.F.F. B.F.G. NL E.C. ABOVE FINISHED FLOOR BELOW FINISHED GRADE VERIFY IN FIELD NIGHT LIGHT (CONNECT TO UNSWITCHED LEG OF LTG CIRCUIT) MECHANICAL CONTRACTOR ELECTRICAL CONTRACTOR MOTOR CONNECTION POINT T EF TELEPHONE / DATA BOARD (GRND AS PER UTIL. CO) TIME CLOCK SWITCHT 1 1 A-1,3 DOUBLE DUPLEX OUTLET (4-PLEX) JUNCTION BOX BRANCH PANELBOARD J EMERGENCY WALL LIGHT WITH 90MIN. BATTERY PHOTOELECTRIC CELL/SWITCH HVAC SYSTEM SENSOR - SEE MECHANICAL E S WALL BOX DIMMER SWITCH. (SWITCH TO BE COMPAT. W/LOAD SERVED) SINGLE POLE SWITCH (SEE SUBSCRIPTS) RECESSED CAN FIXTURE MAIN/DISTRIBUTION PANELBOARD TRAC LIGHT SYSTEM * * PUSHBUTTON (AS INDICATED ON DRAWINGS) ROUGH-IN BOX MUD RING ORIENTATION. RECPT. SUB- SCRIPTS AC=ABOVE COUNTER GFI=GROUND-FAULT IG=ISOLATED GROUND S=SURGE SUPPRESSION TR=UL TAMPER RESISTANT WP=WEATHERPROOF COVER W/GFCI RECEPT. TV= RECPT. FOR TV, SEE ARCH. ELEVATION DWGS FOR MTG. HEIGHT USB=RECEPTACLE W/USB CHARGER CR=CORD REEL (SEE DETAIL) F=FUSED DISCONNECT (FUSE PER EQUIP. NAMEPLATE) DISCONNECT SWITCH (SIZE AND TYPE AS INDICATED) B=ENCLOSED CIRCUIT BREAKER CEILING MOUNTED DUPLEX RECEPTACLE FLOORBOX - POWER ONLY (2-DUPLEX RECEPTACLES) FLOORBOX - MULTISERVICE DUAL-LEVEL SWITCHES; IN-BOARD AND OUT-BOARD LAMPS SHALL BE SWITCHED SEPARATELY. (SUBSCRIPT APPLIES TO BOTH SWITCHES) SWITCH SUB- SCRIPTS 3 = 3-WAY 4 = 4-WAY F = EXHAUST FAN TIMER (INTERMATIC MODEL EI400 SERIES) T = THERMAL OVERLOAD SWITCH W/PILOT LIGHT P = 1-POLE SWITCH WITH PILOT LIGHT. (SEE SPECS) M = SWITCH SUPPLIED W/ EQUIPMENT (INSTALLED BY E.C.) WP = WEATHERPROOF EXIT SIGN, WALL OR CEILING MOUNT & DIRECTIONAL ARROWS AS INDICATED ON DRAWINGS. CONNECT TO UNSWITCHED LEG OF NEAREST LIGHTING CIRCUIT. EMERG. FIXTURE WITH EMERG. BATTERY PACK, CONNECTED TO UNSWITCHED LEG OF LIGHTING CIRCUIT. G.C.GENERAL CONTRACTOR N.T.S.NOT TO SCALE V=VFD (PROVIDED BY M.C. CONNECTED AND INSTALLED BY E.C.) COMBINATION STARTER & FUSED DISCONNECT SWITCH; 2-SETS OF NO/NC CONTACTS, CONTROL XFMR, FUSE PER EQUIP. NAMEPLATE CROSS LINES SHOW # OF PHASE/NEUTRAL CONDUCTORS IF MORE THAN TWO. EQUIPMENT/ISOLATED GROUNDING CONDUCTORS ARE NOT SHOWN. PROVIDE 'GREEN' EQUIP. GROUNDING CONDUCTOR FOR ALL CIRCUITS AND ADDITIONAL ISOLATED GROUND WHERE INDICATED. F M LED 0-10V: LEVITON RENOIR II #AWSMG-7D* W/MATCHING WALL PLATE (* COLOR TO MATCH WIRING DEVICES)S SS S F#E NIGHT LIGHT FIXTURE, CONNECTED FIXTURE TO UNSWITCHED LEG OF LIGHTING CIRCUIT. NL S P SWITCH MOUNTED OCCUPANCY SENSOR, LINE VOLTAGE, W/ COVERPLATE, (COLOR TO MATCH WIRING DEVICES) P = PASSIVE INFRARED,1-POLE [WATTSTOPPER # PW-301] P2 = PASSIVE INFRARED,2-POLE [WATTSTOPPER # PW-302] D = DUAL TECHNOLOGY,1-POLE [WATTSTOPPER # DSW-100] D2 = DUAL TECHNOLOGY,2-POLE [WATTSTOPPER # DSW-200] S CEILING DATA WITH 1" ENT CONDUIT (1) CAT 6 CABLE TO MDF. TERMINATE BOTH ENDS, SEE SPECS. CEILING MOUNTED OCCUPANCY SENSOR BLANK = DUAL TECH., LINE VOLTAGE [WATTSTOPPER #DT-355] L = LARGE AREA, ULTRASONIC LOW VOLTAGE [WATTSTOPPER #WT-2205] H = HALLWAY, ULTRASONIC LOW VOLTAGE [WATTSTOPPER #WT-2255] R = RESTROOM, DUAL TECH., LINE VOLTAGE, 2-POLE [SENSOR SWITCH #CMR-PDT-9-2P], (1) RELAY FOR LTG, (1) RELAY FOR EXHAUST FAN (30 MIN. DELAY) *PROVIDE LOW VOLTAGE SENSORS WITH POWER/RELAY PACK(S) AS REQUIRED FOR OPERATION. [WATTSTOPPER #BZ-50] TO BE MOUNTED AS CLOSE TO TYPICAL DEVICE MOUNTING HEIGHTS DIAGRAM NO SCALE FINISHED FLOOR ARCHITECTURAL PLANS AND DETAILS. DOOR JAMBS AS POSSIBLE. COORDINATE ALL DEVICES WITH 18" T.V. OUTLET ALL MOUNTING HEIGHTS TYPICAL UNLESS NOTED OTHERWISE. ALL SWITCHES AND THERMOSTATS NOTES: THERMOSTAT OR MECHANICAL SWITCH LIGHT SWITCH CONVENIENCE OUTLET TELEPHONE / DATA OUTLET S T T (OR AS NOTED) 5' - 0'' 4' - 0'' 3' - 8'' 50 60 70 80 S A. COORDINATE OUTLET HEIGHTS WITH ARCHITECTS MILLWORK DWGS. TO INSURE THAT OUTLETS WILL NOT FALL BEHIND CABINETS, BACKSPLASHES, OR INTERFERE WITH WAINSCOTING, ETC. (OR AS NOTED) @ MILLWORK XX" * B. D. *COORDINATE LIGHT SWITCH & OUTLET HEIGHTS WITH ARCHITECTURAL WAINS- COTING AND OR TILE WORK SO AS NOT TO FALL MIDWAY IN THESE FINISHES. * VERIFY WITH MECH. MUD RING ORIENTATION. VOLTAGE DROP SCHEDULE CONDUCTOR SIZE IS TO BE DETERMINED FROM THE FOLLOWING SCHEDULE 120 VOLT, 20A. CIRCUITS #12 CONDUCTOR FOR CIRCUITS WITH A MAXIMUM LENGTH OF 136' #10 CONDUCTOR FOR CIRCUITS WITH A MAXIMUM LENGTH OF 216' #8 CONDUCTOR FOR CIRCUITS WITH A MAXIMUM LENGTH OF 343' 1.ELECTRICAL CONTRACTOR SHALL REFER TO THE MECHANICAL DRAWINGS FOR EXACT LOCATION OF ALL MECHANICAL EQUIPMENT AND ELECTRICAL CONNECTIONS. 2.ELECTRICAL CONTRACTOR SHALL PROVIDE MINIMUM WORKING CLEARANCE AS PER NEC BEFORE INSTALLING ANY ELECTRICAL PANELS FOR CABINETS. 3.INSTALL ALL LIGHT FIXTURES IN MECHANICAL ROOM AFTER THE MECHANICAL EQUIPMENT IS IN PLACE, ADJUST AS NECESSARY. PROVIDE CHAIN SUSPENSION KITS AS REQUIRED. 4.REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FIXTURE LOCATIONS, CEILING TYPES, ETC. 5.ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONCRETE PADS AS REQUIRED ON ALL ELECTRICAL EQUIPMENT. 6.CONFIRM EXACT LOCATIONS OF ALL TELEPHONE / DATA OUTLETS WITH OWNER PRIOR TO ROUGH - IN. 7.LOCATE SWITCHES, OUTLETS, ETC., SHOWN AT ROOM ENTRY DOORWAYS, AS CLOSE TO DOOR FRAME AS POSSIBLE, SO AS NOT TO INTERFERE WITH ROOM CABINETS, ETC. 8.SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING. 9.ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR THIS WORK AND PAY ASSOCIATED FEES. 10.MAINTAIN 24" MIN. CLEARANCE FROM ALL COMMUNICATIONS CABLES AND ELECTRONIC BALLASTS. 11.ALL BATTERY EXIT AND EMERGENCY LIGHTING TO BE CONNECTED TO THE UNSWITCHED LEG OF THE LIGHTING CIRCUIT IN THE AREA AS PER CODE. 12.UNLESS SPECIFICALLY INDICATED OTHERWISE, THE ELECTRICAL CONTRACTOR TO COORDINATE WITH ANY SPECIAL SYSTEMS SUPPLIER /CONTR., EX. DENTAL, MEDICAL, KITCHEN,EQUIPMENT ETC. THE EXACT ROUGH-IN REQUIREMENTS FOR THERE EQUIPMENT. ALSO UNLESS INDICATED OTHERWISE, THE ELECTRICAL CONTR. TO BE RESPONSIBLE FOR FINAL CONNECTIONS TO ALL SPECIAL EQUIPMENT. 13.ALL CONDUIT /RACEWAY /CABLES, TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. IF ANY SURFACE WORK IS NECESSARY, IT SHALL BE APPROVED BY THE ARCHITECT /ENGINEER PRIOR TO DOING ANY WORK. 14.E.C. SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE EXISTING CONDITIONS, AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED. MAKE NECESSARY PROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS. 15.JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY. THE E.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTED FOR "THROUGH-BRANCH CIRCUIT WIRING". 16.ALL LIGHTING CONTROLS SHALL BE PROVIDED AND INSTALLED BY E.C. 17.THE BRANCH CIRCUITRY SHALL BE DESIGN/BUILD BY THE E.C. INSTALLATION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, 2014 NEC AND GOOD ELECTRICAL PRACTICES. WIRING SHALL BE INSTALLED TO MAINTAIN A MINIMUM OF 3% VOLTAGE DROP. PROJECT GENERAL NOTES: WALL ROUGH-IN FOR DATA AND CATV WITH 1" ENT CONDUIT (1) CAT 6A CABLE TO MDF. TERMINATE BOTH ENDS, SEE SPECS. E1.0 EL E C T R I C A L N O T E S , D E T A I L S A N D SC H E D U L E S Visit the site and become acquainted with conditions to be encountered. Extra funds will not be allowed due to failure to examine site and to standard practices of the trade. All materials shall, unless otherwise all work and pay all costs for complete and operating systems, as contractor shall verify the exact requirements for the electric and be of the same type, material and manufacture for ease of future cutting and driling of structure only with prior approval of the owner. Where cutting and patching of work is necessary, use same materials proper functioning and shall be left in first class operating condition. ducts installed by other trades. Install conduit runs exposed to view All materials, fixtures and equipment shall be covered or sealed upon All equipment shall be readily accessible for maintenance and repairs. workmanship and finish to neatly match all surrounding work. 4" minimum horizontally, 12" minimum from other utility lines. Minimum conduit Each piece of equipment and all of the systems shall be adjusted to insure to final completion and acceptance of the work. Such preliminary operation The owner reserves the right to operate any systems of equipment prior Support conduit with one-hole malleable factory made pipe straps, fastened Raceway Installation: Separate underground conduits in a common trench installation so as to provide for safety and to insure that operation and noted, be new and in perfect condition. All material for similar uses shall Do all drilling and cutting as necessary for installation of equipment. Do depth shall be 18". Coordinate conduit installation with pipes, steel and parallel or at right angles to structural members, walls or building lines. appearance will be maintained after subsequent construction operations. telephone services with the utility company representatives and provide These plans have been prepared without utility company comments. The All workmanship shall be performed by skilled mechanics using the best CUTTING AND PATCHING: OPERATING AND ADJUSTING: shall not be construed as an acceptance of any work. 9. with screws. EXECUTION: 8. directed by the governing utilities. include existing conditions in bid price. MATERIALS AND WORKMANSHIP: COORDINATION WITH UTILITIES: maintenance. 7. 6. Panelboards: Circuit breakers shall be 10,000 AIC minimum. All locks keyed alike and typewritten directories. All panels shall have a minimum of 36" working in neat, clean and usable condition. Remove all cement, paint, grease, oil all exposed fixtures, trim and equipment, and leave the entire installation Upon completion of the work, prior to final inspection, thoroughly clean Prior to final acceptance of the project, deliver to the owner a written any defective work. Demonstrate continuous satisfactory operation of Test all wire for shorts, opens, grounds, or other defects. Correct damaged due to faulty work and materials furnished under this section. this period, including repair or replacement of the premises that may be repair or replace all such defective items promptly that may occur during one year guarantee on all workmanship, materials and equipment and agree to Selected by owner, installed by electrical contr. 17.CLEAN-UP: GUARANTEE: all electrical equipment. and other foreign substances. 19. 18.TEST: LIGHTING FIXTURES: DEVICE PLATES: SERVICE EQUIPMENT: clearance in front of panel. All dimensions to be field verified. 16. 15. 14. required, including all conduits and wires indicated, including control conduits Complete and operable systems of electrical lighting, power and receptacles. Alterations and additions including conduit, wiring, outlets, fixtures, devices All work and materials shall comply with all applicable codes, safety orders, detailed as specified to a more restrictive standard or higher requirement. having jurisdiction including regulations of the State Fire Marshall, unless laws, ordinances and regulations of governing authorities and other agencies The electrical drawings are essentially diagrammatic in that all provisions All work, material and equipment called for by notes, schedules or otherwise indicated on the drawings shall be furnished and installed as though fully to conform and to avoid obstructions, without additional cost to the owner. systems can not be shown. All installations shall be adjusted as necessary necessary to conform to structural, architectural, mechanical and plumbing ELECTRICAL SPECIFICATIONS COMPLIANCE WITH CODES: INTERPRETATION OF DRAWINGS: VISITING THE SITE: set forth in these specifications. 5. 4. 3. Connections to all A.C. equipment as indicated and and outlets. 2. INTENT: and lamps. 1. All conduit shall be continuous for grounding. All grounding conductors As required by code and as directed by owner. pressure connectors for larger wire. All wiring shall be copper. #14 AWG unless noted. Use "Ideal Yellow" pulling compound for all pulls. Use Scotchlock connectors for all splices in #12 wire and taped bolted Type THWN or THHN copper wire insulated for 600V. Smallest wire shall be CONDUCTORS: DEVICES: GROUNDING: shall be insulated green copper, sized as shown. 12. 13. 11. CONDUIT AND WIRING METHODS:10. As required by code and as directed by owner. ·All wiring methods shall be installed in accordance with the 2014 NEC. ·Type NM and SER Cable is allowed in R-2 areas in accordance with local AJH and NEC. ·MC cable is allowed where concealed in walls, ceilings or floors. ·All surface/exposed feeders and branch circuits shall be: Conductors in Raceway. ·All wiring within finished spaces shall be concealed; surface mounted raceway is prohibited. ·All underground wiring shall be: Conductors in Raceway. Direct Bury cable is prohibited. TELEPHONE/DATA SYSTEMS 1.1 Summary A.Includes But Not Limited To 1.Furnish and install all the equipment, materials, terminations and labor necessary to provide a complete CAT6 Telephone/Data and Television cabling system as described in Contract Documents including, but not limited to, raceway, outlets, modular jacks, device plates, cables, punch down blocks, backboards, cabinets, patch panels, grounding and other miscellaneous items required for a complete system. 2.Furnish and install main service raceway as described in Contract Documents and to comply with local telephone company requirements. 3.Refer to Drawings for conduit sizes and quantity of cables/jacks at each outlet location. 1.2 Warranty A.A Lifetime product warranty covering all components, equipment and workmanship shall be submitted in writing with system documentation. The warranty period shall begin on the system's first use by the owner. Warranty shall be vendor supplied. Contractor warranty alone is unacceptable. B.The project must be pre-registered with Manufacturer before installation has begun. 2.1 Components A.Boxes shall be a 4 square deep box with single-gang mudring. B.Telephone and Computer Network System Cable 1.23 gauge, solid annealed copper, 4-pairs. CAT6A 2.Use plenum-rated cable in ceilings and areas used for plenum air return 3.Provide Owner with patch panels, quantity as required. 4.Different colors of cabling shall be used; (Yellow - Telephone, Blue - Network) 5.Manufacturers: a.Superior Essex b.Alternate manufacturer with equivalent performance standard. C.Equipment Racks 1.Provide a minimum of (1) 19" wall mounted rack at each comm. board location 2.Provide with 20A power strip, wire management and rack mounting kits. 3.Manufacturers: a.Cooper B-line b.Alternate manufacturer with equivalent performance standard. D.Telephone Termination Blocks 1.UL verified CAT6. 2.66 termination with tin lead plated IDC D.Telephone & Network Patch Panels 1.UL verified CAT6A. 2.110 termination with tin lead plated IDC 3.19" rack mount with backboard mounting frame. 4.48 Ports 5.Manufacturers: a.Leviton b.Alternate manufacturer with equivalent performance standard. E.Telephone/Network Jacks & Faceplates 1.Wall Jacks a.CAT6A - Color to match cable color. 2.Faceplates a.Color to be as specified by Owner. b.Provide and install Blank inserts as needed. 3.Manufacturers: a.Leviton b.Alternate manufacturer with equivalent performance standard. F.Cables shall be installed in conduit from outlet to above nearest accessible ceiling space, install J-hooks above accessible ceiling space 3ft on center for supporting cable. Install cable from terminal board/data rack to each telephone/network outlet. G.Terminate cables at each outlet with specified modular jack assembly. H.Terminate cables on punch down blocks or patch panels at terminal board. I.All Faceplates, patch panels and cables shall be labeled depicting location, Cables shall be labeled on both ends. J.Terminate cabling according to EIA/TIA 568B.1 Standards. K. Installation of all materials shall be as recommended by manufacturer. 3.2 Quality Assurance A.Comply with applicable portions of NEC ANSI/EIA/TIA 568 as to type products used and installation of components. Provide products and materials which have been UL-listed and labeled. B.Cabling system shall meet the performance requirements of the ANSI/TIA/EIA-568-B Standards (Annex E). C.Each cable and patch cable shall be tested from the outlet location to the patch panel, the system shall be tested to Category 6 Level II compliance. The test path shall include workstation jacks, Horizontal cabling and patch panels. Contractor shall replace any equipment or cabling that fails and retest. Provide Owner with complete test reports of cabling system. TV WALL ROUGH IN FOR DATA AND CATV WITH 1" ENT CONDUIT WITH (1) CAT 6A CABLE AND (1) RG6 COAX CABLE TO APT DISTRIBUTION. TERMINATE BOTH ENDS, SEE SPECS. 6" 3/4" C., 1#6 B.C. GRND. CONNECT TO BLDG. GROUND SYSTEM FINISH FLOOR TYPICAL CONDUITS OUT TO VOICE/ DATA OUTLETS. SEE PLAN FOR SIZE, ETC. (TYPICAL TOP & OR BOTTOM OF BOARD) SCALE: NONE TELEPHONE / DATA TERMINAL BOARD - DETAIL 4'X8'X3/4" PLYWOOD PRIME & PAINT W/TWO COATS GREY ENAMEL (INSTALL ON WALLS AS INDICATED ON PLANS) ANCHOR SECURELY TO WALL W/ CONST. ADHESIVE. DOUBLE-DUPLEX OUTLET(S) PER PLANS 120V CIRCUIT PER PLANS PULL CORD UNISTRUT ANCHOR INCOMING UTILITY SERVICE CONDUIT(S) WITH INSULATED BUSHING. SEE SITE PLAN FOR SIZE, QUANTITY, ETC. GROUND BAR (SQ. D #PK27GTA) TELEPHONE, DATA, TV EQUIPMENT (TYP) INSTALL INSULATED BUSHING ON ALL CONDUIT ENDS. (TYP) UNISTRUT ANCHOR M M MM M M M M M MM M M M M M TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY MA D I S O N S Q U A R E 05-2020 STAFF P.E. JOB #2020 Pocatello, Idaho 83201 1823 E. Center tel (208) 232-4439 www.payneengineeringinc.com REXBURG, ID AP A R T M E N T S E1.1 EL E C T R I C A L N O T E S , D E T A I L S A N D SC H E D U L E S SCALE: FRONT ELEVATION - LIGHTING 1/8" = 1' - 0"16'8'0" SCALE: RIGHT ELEVATION - LIGHTING 1/8" = 1' - 0"16'8'0"SCALE: LEFT ELEVATION - LIGHTING 1/8" = 1' - 0"16'8'0" SCALE: BACK ELEVATION - LIGHTING 1/8" = 1' - 0"16'8'0" SPECIAL NOTES: 1. CONTROL EXTERIOR LIGHTING PHOTO-CELL ON TIME CLOCK OFF. 2. CONNECT EXTERIOR LIGHTING TO HOUSE PANEL CIRCUIT. 2 CU 1 CU 2 CU 1 CU 1 CU 3 CU 2 CU 1 CU 2 CU 1 CU 1 CU 1 CU 3 CU 3 CU 1 CU 1 EH METER PACK 1 COMMUNICATION BOARD TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY MA D I S O N S Q U A R E 05-2020 STAFF P.E. JOB #2020 Pocatello, Idaho 83201 1823 E. Center tel (208) 232-4439 www.payneengineeringinc.com REXBURG, ID AP A R T M E N T S E1.2 HO U S E E L E C T R I C A L PL A N S SCALE: LEVEL 1 - HOUSE ELECTRICAL 1/8" = 1' - 0"16'8'0" SCALE: LEVEL 2 - HOUSE ELECTRICAL 1/8" = 1' - 0"16'8'0" SPECIAL NOTES: 1. CONTROL EXTERIOR LIGHTING PHOTO-CELL ON TIME CLOCK OFF. 2. CONNECT EXTERIOR LIGHTING TO HOUSE PANEL CIRCUIT. KEY NOTES 1 PROVIDE AND INSTALL (1) 4" AND (1) 2" CONDUIT TO PROPERTY LINE FROM COMM. SERVICES CABLING. COORDINATE EXACT POINT OF ENTRY WITH SERVICE PROVIDER. TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY MA D I S O N S Q U A R E 05-2020 STAFF P.E. JOB #2020 Pocatello, Idaho 83201 1823 E. Center tel (208) 232-4439 www.payneengineeringinc.com REXBURG, ID AP A R T M E N T S E1.3 HO U S E E L E C T R I C A L PL A N SCALE: LEVEL 3 - HOUSE ELECTRICAL 1/8" = 1' - 0"16'8'0" SPECIAL NOTES: 1. CONTROL EXTERIOR LIGHTING PHOTO-CELL ON TIME CLOCK OFF. 2. CONNECT EXTERIOR LIGHTING TO HOUSE PANEL CIRCUIT. 3 F F F F 3 3 F F SS 3SS 3 SS F SS F TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY MA D I S O N S Q U A R E 05-2020 STAFF P.E. JOB #2020 Pocatello, Idaho 83201 1823 E. Center tel (208) 232-4439 www.payneengineeringinc.com REXBURG, ID AP A R T M E N T S E2.0 TO W N H O M E # 1 EL E C T R I C A L P L A N S WIRE THIS OUTLET SUCH THAT THE TOP POWERS THE DISHWASHER, THE BOTTOM POWERS THE DISPOSAL. MICROWAVE ABOVE PROVIDE 120V. TO HOOD ABOVE RANGE ALL RECEPTACLES IN KITCHEN SHALL BE GFCI. SCALE: TOWN HOME #1 BASEMENT - POWER 1/8" = 1' - 0"16'8'0" SCALE: TOWN HOME #1 BASEMENT - LIGHTING 1/8" = 1' - 0"16'8'0" SCALE: TOWN HOME #1 1ST LEVEL - POWER 1/8" = 1' - 0"16'8'0" SCALE: TOWN HOME #1 1ST LEVEL - LIGHTING 1/8" = 1' - 0"16'8'0" SCALE: TOWN HOME #1 2ND LEVEL - POWER 1/8" = 1' - 0"16'8'0" SCALE: TOWN HOME #1 2ND LEVEL - LIGHTING 1/8" = 1' - 0"16'8'0" (TYPICAL)(TYPICAL)(TYPICAL) (TYPICAL)(TYPICAL)(TYPICAL) LIGHTING/RECEPTS -- 120/240V. 1PH. 3W. SQ D QO LOAD CENTER - TOWN HOME #1 PANEL 20 1 - - 1 20 125 14"X24"X4" SEE LOAD CALCULATIONS - -- - - SPARE PREPARED SPACE WASHER DRYER 30 2 - LIGHTING/RECEPTS SPARE PREPARED SPACE 20 1 2 - 40 RANGE -- 2 - 60 COND. UNIT * -- FIRE ALARM SYSTEM NOTE: E.C. SHALL PROVIDE AND INSTALL A COMPLETE BUILDING FIRE ALARM SYSTEM TO MEET NFPA 72, 2012 IFC AND ANY LOCAL CITY REQUIREMENTS. PROVIDE ALL DOCUMENTATION, DRAWINGS, CALC'S AND ETC. TO CITY FOR PERMITTING AND INSTALLATION. SPECIAL NOTES A.PROVIDE ARC-FAULT BREAKERS ON ALL NEC REQUIRED CIRCUITS. REFER TO NEC CODE SECTION 210.12 B. D.EVEN IF SPECIFICALLY INDICATED ON DRAWINGS, ALL DEVICES SHOWN AT OR NEAR MILLWORK / CASEWORK, SHALL BE COORDINATED WITH THE ARCHITECTURAL CASEWORK ELEVATION DWGS., TO INSURE PROPER MOUNTING HEIGHTS, ETC. ADJUST AS NECESSARY, TO POSITION DEVICES SUCH THAT THEY WILL NOT FALL BEHIND MILLWORK, CABINETS, OR BE DIRECTLY ABOVE SINKS, OR MIDWAY BETWEEN TILEWORK / WALL OR WAINSCOATING, ETC. C.PROVIDE TAMPER-PROOF TYPE RECEPTACLES IN ALL REQUIRED AREAS AS PER CODE. REFERENCE NEC CODE SECTION 406.11. PROVIDE AND INSTALL ALL REQUIRED DEVICES AND CIRCUITS REQ'D IN DWELLING UNITS AS DESCRIBED IN ART. 210 NEC. GENERAL LOADS 2,600 SQ FT X 3 VA PER SQ FT SUB-TOTAL (HVAC LOAD) HVAC LOADS APPLICATION OF DEMAND FACTORS SERVICE SIZE RECOMMENDED SERVICE SIZE IN AMPS MIN. SERVICE SIZE IN AMPS (27,620VA @ 120/240 1PH. 3W) REMAINDER (17,800) @ 40% WIRING: #1cu in conduit or #1/0 Al 3-Conductor SER cable HVAC LOAD @ 100% PER NEC BREAKER FIRST 10000 @ 100% TOTAL DEMAND GENERAL LOAD PER NEC 220.82 HVAC F/1 GENERAL LIGHTING/POWER SMALL APPLIANCE (KITCHEN) 2-CIRCUITS 10,000 VA 27,620 VA 115 AMPS 125 AMPS 125A-2P = = = =1,000 VA 7,800 VA 3,000 VA= = 27,800VASUB-TOTAL (GENERAL LOADS) RANGE LOAD DRYER DISHWASHER = = = 8,000 VA 5,000 VA 1,000 VA 10,500 VA 7,120 VA 10,500 VA SMALL APPLIANCE (LAUNDRY) 1-CIRCUITS SMALL APPLIANCE (BATH) 1-CIRCUITS 1,500 VA= 1,500 VA= E.E.C. SHALL COORDINATE THE EXACT PLACEMENT OF ALL WALL DEVICES WITH OWNER PRIOR TO ROUGH-IN. WATER HEATER =4,500 VA FURNACE 2 - 30 WATER HEATER -- COND. UNIT =5,000 VA 1 20 * E.C. SHALL COORDINATE COND. UNIT BREAKER SIZE WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING. 3 SS3 3 F F 3 F F 3 3 TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY MA D I S O N S Q U A R E 05-2020 STAFF P.E. JOB #2020 Pocatello, Idaho 83201 1823 E. Center tel (208) 232-4439 www.payneengineeringinc.com REXBURG, ID AP A R T M E N T S E2.1 TO W N H O M E # 2 EL E C T R I C A L P L A N S WIRE THIS OUTLET SUCH THAT THE TOP POWERS THE DISHWASHER, THE BOTTOM POWERS THE DISPOSAL. ALL RECEPTACLES IN KITCHEN SHALL BE GFCI. SCALE: TOWN HOME #2 BASEMENT - POWER 1/8" = 1' - 0"16'8'0" SCALE: TOWN HOME #2 BASEMENT - LIGHTING 1/8" = 1' - 0"16'8'0" SCALE: TOWN HOME #2 1ST LEVEL - POWER 1/8" = 1' - 0"16'8'0" SCALE: TOWN HOME #2 1ST LEVEL - LIGHTING 1/8" = 1' - 0"16'8'0" LIGHTING/RECEPTS -- 120/240V. 1PH. 3W. SQ D QO LOAD CENTER - TOWN HOME #2 PANEL 20 1 - - 1 20 125 14"X24"X4" SEE LOAD CALCULATIONS - -- - - SPARE PREPARED SPACE WASHER DRYER 30 2 - LIGHTING/RECEPTS SPARE PREPARED SPACE 20 1 2 - 40 RANGE -- 2 - 50 COND. UNIT * -- FIRE ALARM SYSTEM NOTE: E.C. SHALL PROVIDE AND INSTALL A COMPLETE BUILDING FIRE ALARM SYSTEM TO MEET NFPA 72, 2012 IFC AND ANY LOCAL CITY REQUIREMENTS. PROVIDE ALL DOCUMENTATION, DRAWINGS, CALC'S AND ETC. TO CITY FOR PERMITTING AND INSTALLATION. SPECIAL NOTES A.PROVIDE ARC-FAULT BREAKERS ON ALL NEC REQUIRED CIRCUITS. REFER TO NEC CODE SECTION 210.12 B. D.EVEN IF SPECIFICALLY INDICATED ON DRAWINGS, ALL DEVICES SHOWN AT OR NEAR MILLWORK / CASEWORK, SHALL BE COORDINATED WITH THE ARCHITECTURAL CASEWORK ELEVATION DWGS., TO INSURE PROPER MOUNTING HEIGHTS, ETC. ADJUST AS NECESSARY, TO POSITION DEVICES SUCH THAT THEY WILL NOT FALL BEHIND MILLWORK, CABINETS, OR BE DIRECTLY ABOVE SINKS, OR MIDWAY BETWEEN TILEWORK / WALL OR WAINSCOATING, ETC. C.PROVIDE TAMPER-PROOF TYPE RECEPTACLES IN ALL REQUIRED AREAS AS PER CODE. REFERENCE NEC CODE SECTION 406.11. PROVIDE AND INSTALL ALL REQUIRED DEVICES AND CIRCUITS REQ'D IN DWELLING UNITS AS DESCRIBED IN ART. 210 NEC. GENERAL LOADS 1900 SQ FT X 3 VA PER SQ FT SUB-TOTAL (HVAC LOAD) HVAC LOADS APPLICATION OF DEMAND FACTORS SERVICE SIZE RECOMMENDED SERVICE SIZE IN AMPS MIN. SERVICE SIZE IN AMPS (26,780VA @ 120/240 1PH. 3W) REMAINDER (15,700) @ 40% WIRING: #1cu in conduit or #1/0 Al 3-Conductor SER cable HVAC LOAD @ 100% PER NEC BREAKER FIRST 10000 @ 100% TOTAL DEMAND GENERAL LOAD PER NEC 220.82 HVAC F/1 GENERAL LIGHTING/POWER SMALL APPLIANCE (KITCHEN) 2-CIRCUITS 10,000 VA 26,780 VA 111 AMPS 125 AMPS 125A-2P = = = =1,000 VA 5,700 VA 3,000 VA= = 25,700VASUB-TOTAL (GENERAL LOADS) RANGE LOAD DRYER DISHWASHER = = = 8,000 VA 5,000 VA 1,000 VA 10,500 VA 6,280 VA 10,500 VA SMALL APPLIANCE (LAUNDRY) 1-CIRCUITS SMALL APPLIANCE (BATH) 1-CIRCUITS 1,500 VA= 1,500 VA= E.E.C. SHALL COORDINATE THE EXACT PLACEMENT OF ALL WALL DEVICES WITH OWNER PRIOR TO ROUGH-IN. WATER HEATER =4,500 VA FURNACE 2 - 30 WATER HEATER -- (TYPICAL)(TYPICAL) (TYPICAL)(TYPICAL) COND. UNIT =5,000 VA 1 20 * E.C. SHALL COORDINATE COND. UNIT BREAKER SIZE WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING. F F TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY MA D I S O N S Q U A R E 05-2020 STAFF P.E. JOB #2020 Pocatello, Idaho 83201 1823 E. Center tel (208) 232-4439 www.payneengineeringinc.com REXBURG, ID AP A R T M E N T S E2.2 TY P I C A L A P A R T M E N T EL E C T R I C A L P L A N S ALL RECEPTACLES IN KITCHEN SHALL BE GFCI. WIRE THIS OUTLET SUCH THAT THE TOP POWERS THE DISHWASHER, THE BOTTOM POWERS THE DISPOSAL. SCALE: APARTMENT - POWER 1/8" = 1' - 0"16'8'0" LIGHTING/RECEPTS -- 120/240V. 1PH. 3W. SQ D QO LOAD CENTER - APT. PANEL 20 1 - - 1 20 125 14"X24"X4" SEE LOAD CALCULATIONS - -- - - SPARE PREPARED SPACE WASHER DRYER 30 2 - LIGHTING/RECEPTS SPARE PREPARED SPACE 20 1 2 - 40 RANGE -- 2 - 30 COND. UNIT * -- FIRE ALARM SYSTEM NOTE: E.C. SHALL PROVIDE AND INSTALL A COMPLETE BUILDING FIRE ALARM SYSTEM TO MEET NFPA 72, 2012 IFC AND ANY LOCAL CITY REQUIREMENTS. PROVIDE ALL DOCUMENTATION, DRAWINGS, CALC'S AND ETC. TO CITY FOR PERMITTING AND INSTALLATION. SPECIAL NOTES A.PROVIDE ARC-FAULT BREAKERS ON ALL NEC REQUIRED CIRCUITS. REFER TO NEC CODE SECTION 210.12 B. D.EVEN IF SPECIFICALLY INDICATED ON DRAWINGS, ALL DEVICES SHOWN AT OR NEAR MILLWORK / CASEWORK, SHALL BE COORDINATED WITH THE ARCHITECTURAL CASEWORK ELEVATION DWGS., TO INSURE PROPER MOUNTING HEIGHTS, ETC. ADJUST AS NECESSARY, TO POSITION DEVICES SUCH THAT THEY WILL NOT FALL BEHIND MILLWORK, CABINETS, OR BE DIRECTLY ABOVE SINKS, OR MIDWAY BETWEEN TILEWORK / WALL OR WAINSCOATING, ETC. C.PROVIDE TAMPER-PROOF TYPE RECEPTACLES IN ALL REQUIRED AREAS AS PER CODE. REFERENCE NEC CODE SECTION 406.11. PROVIDE AND INSTALL ALL REQUIRED DEVICES AND CIRCUITS REQ'D IN DWELLING UNITS AS DESCRIBED IN ART. 210 NEC. GENERAL LOADS 900 SQ FT X 3 VA PER SQ FT SUB-TOTAL (HVAC LOAD) HVAC LOADS APPLICATION OF DEMAND FACTORS SERVICE SIZE RECOMMENDED SERVICE SIZE IN AMPS MIN. SERVICE SIZE IN AMPS (23,580VA @ 120/240 1PH. 3W) REMAINDER (12,700) @ 40% WIRING: #1cu in conduit or #1/0 Al 3-Conductor SER cable HVAC LOAD @ 100% PER NEC BREAKER FIRST 10000 @ 100% TOTAL DEMAND GENERAL LOAD PER NEC 220.82 HVAC F/1 GENERAL LIGHTING/POWER SMALL APPLIANCE (KITCHEN) 2-CIRCUITS 10,000 VA 23,580 VA 98 AMPS 1250 AMPS 125A-2P = = = =1,000 VA 2,700 VA 3,000 VA= = 22,700VASUB-TOTAL (GENERAL LOADS) RANGE LOAD DRYER DISHWASHER = = = 8,000 VA 5,000 VA 1,000 VA 8,500 VA 5,080 VA 8,500 VA SMALL APPLIANCE (LAUNDRY) 1-CIRCUITS SMALL APPLIANCE (BATH) 1-CIRCUITS 1,500 VA= 1,500 VA= E.E.C. SHALL COORDINATE THE EXACT PLACEMENT OF ALL WALL DEVICES WITH OWNER PRIOR TO ROUGH-IN. WATER HEATER =4,500 VA FURNACE 2 - 30 WATER HEATER -- SCALE: APARTMENT - LIGHTING 1/8" = 1' - 0"16'8'0" (TYPICAL)(TYPICAL) COND. UNIT =3,000 VA 1 20 * E.C. SHALL COORDINATE COND. UNIT BREAKER SIZE WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING. TH E S E D R A W I N G S O R A N Y P A R T S T H E R E O F , A S I N S T R U M E N T S O F S E R V I C E , R E M A I N T H E P R O P E R T Y O F T H E A R C H I T E C T S A N D M A Y N O T B E R E P R O D U C E D O R U S E D O N O T H E R W O R K W I T H O U T T H E I R W R I T T E N C O N S E N T REVISIONS 35 2 0 N U N I V E R S I T Y A V E N U E # 2 0 0 , P R O V O U T 8 4 6 0 4 8 0 1 - 3 7 7 - 6 3 0 3 W W W . H A R R I S - A R C H I T E C T U R E . C O M DRAWN BY MA D I S O N S Q U A R E 05-2020 STAFF P.E. JOB #2020 Pocatello, Idaho 83201 1823 E. Center tel (208) 232-4439 www.payneengineeringinc.com REXBURG, ID AP A R T M E N T S E3.0 TY P I C A L A P A R T M E N T EL E C T R I C A L P L A N S APARTMENT LOADS APPLICATION OF DEMAND FACTORS SERVICE SIZE RECOMMENDED SERVICE SIZE IN AMPS MIN. SERVICE SIZE IN AMPS 207,720 VA @ 120/240 1Ø 3W) BREAKER 509,300 VA X .4 TOTAL DEMAND GENERAL LOAD PER NEC 220.84 APARTMENT: 8 UNITS X 31,200 VA 203,720 VA 207,720 VA 865 AMPS 1000 AMPS 1000A-2P = = SUB-TOTAL (DWELLING LOADS) 249,600 VA 509,300 VA NO SCALE 15 UNIT SERVICE M M MM M M M M M GROUND PER NEC 125A 2P BREAKER (TYPICAL) MM CONDUIT AND WIRE AS DIRECTED BY POWER COMPANY 23,158 AVAILABLE FAULT CURRENT 12,450 AVAILABLE FAULT CURRENT M TYPICAL UNIT OR HOUSE PANEL 1 1/2"C., 3-#1 + GROUND CU OR 1/0 SER AL CABLE M M M M * ENGINEERING OPINION OF PROBABLE DEMAND: 110KW 1000 AMP. MAIN BRKR. 1Ø, 3W 120/240V 120/240V 1Ø POWER CO. TRANSFORMER E.C. SHALL PROVIDE AND INSTALL A HOUSE PANEL WITH BREAKERS AS REQUIRED FOR ALL COMMON LOADS. TOWN HOME 2 STORY: 4 UNITS X 36,200 VA =144,800 VA TOWN HOME 3 STORY: 3 UNITS X 38,300 VA =114,900 VA HOUSE PANEL 4,000 VA=