Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WINDOW DETAIL - 22-00821 - Shelfology - Addition
AR 1553 LICENSED ARCHITECT ELMO JAY CHRISTOPHERSON STATE OF IDAHO TYPE "A" SEE SCHEDULE SE E S C H E D U L E SOLID CORE WOOD DOOR HARDWARE SET - 1: LOCKSET A. HAGAR MORTISE LOCKSET, #3410 FINISH TO MATCH BLDG STD. 40" A.F.F. TO CENTERLINE OF LEVER. B. 4 1/2" X 4 1/2" HAGER BB-1279 FINISH TO MATCH LEVER, BUTT HINGES TWO PAIR. 3' - 0 " 2'-0" 4' - 0 " TYPE "AA" FIXED WINDOW 1- 2- Level 1 0' -0" A 3" SPRAY INSULATION R-18 CORRUGATED MTL PANEL TO MATCH EXISTING STRUCTURAL WOOD FRAMING, REFER TO STRUCTURAL MTL BASE ANGLE FLASHING 5/8" TYPE GYPSUM Level 1 0' -0" 5/8" GYPSUM BOARD 2X6 SILL PLATE 2X6 STUD WALL 11/2" PLYWOOD 2X6 JOIST 16" OC 2X6 JOIST RIM JOIST 2X6 DOUBLE HEADER 2X6 STUD FRAMING 16" OC 5/8" GYPSUM BOARD STEEL SUPPORT ANGLE 2X6 JOIST RIM JOIST 3" SPRAY INSULATION R-18 STRUCTURAL WOOD FRAMING, REFER STRUCTURAL CORRUGATED METAL PANELS TO MATCH EXISTING A CORRUGATED MTL PANEL TO MATCH EXISTING 3" SPRAY INSULATION R-18 CORRUGATED MTL PANEL TO MATCH EXISTING STRUCTURAL WOOD FRAMING, REFER TO STRUCTURAL GLULAM BEAM REFER TO STRUCTURAL 4" SPRAY INSULATION R-24 5/8" TYPE GYPSUM 0' - 2" 0' - 0 5 / 8 " 0' - 2"VARIES 0' - 0 1/2" 0' - 2 " 08 11 13.B00 STEEL FRAME 08 11 13.A00 STEEL DOOR EXTERIORINTERIOR 5/8" TYPE C GYPSUM (4HR FIRE RATED) STANDARD 2X4 WOOD STUD 0' - 2"0' - 2"VARIES 1/2" TRANSITION MUST COMPLY WITH ACCESSIBLE TRANSITION REQUIREMENTS. SEE ACCESSIBILITY DETAILS. DOOR AND JAMB BEYOND EXTERIORINTERIOR 08 11 13.A00 STEEL DOOR 08 41 13.O00 WEATHER SWEEP 08 41 13.N00 THRESHOLD 07 27 26.A00 ? 09 24 00.A00 PORTLAND CEM PLAS 05 40 00.L01 GLASS-MAT GYP SHEATHING BOARD 05 40 00.C00 STEEL STUD 1" T Y P 0' - 0 7 / 8 " 0' - 2 " 0' - 0 5/8" 0' - 2 " VA R I E S 0' - 0 1 / 2 " 0' - 2"COORD WITH EXTERIOR WALL +/- 0' - 5 1/4" 08 11 13.B00 STEEL FRAME 08 11 13.A00 STEEL DOOR EXTERIOR INTERIOR 3" SPRAY INSULATION R-18 CORRUGATED MTL PANEL TO MATCH EXISTING WOOD FRAMING TO SUPPORT WINDOW. WINDOW TO BE HUNG FROM STRUCTURAL BEAMS WITH BLOCKING AS REQUIRED. 5/8" TYPE GYPSUM OSB SHEATHING PER STRUCTURAL DRAWINGS BUILDING WRAP WINDOWS TO BE TAPED WINDOW FRAME CORRUGATED MTL PANEL TO MATCH EXISTING STRUCTURAL WOOD FRAMING, REFER TO STRUCTURAL OSB SHEATHING PER STRUCTURAL DRAWINGS BUILDING WRAP WINDOWS TO BE TAPED WINDOW FRAME 5/8" TYPE GYPSUM CORRUGATED MTL PANEL TO MATCH EXISTING STRUCTURAL WOOD FRAMING, REFER TO STRUCTURAL OSB SHEATHING PER STRUCTURAL DRAWINGS BUILDING WRAP WINDOWS TO BE TAPED WINDOW FRAME 5/8" TYPE GYPSUM WOOD FRAMING TO SUPPORT WINDOW. WINDOW TO BE HUNG FROM STRUCTURAL BEAMS WITH BLOCKING AS REQUIRED. © Two Crows Collaboratve Date Description Project Name Project Number Description Scale Seal / Signature 2022 Tel 854.429.335530 STEPPING STONE WAY BLUFFTON, SC 29910 As indicated 8/23/2023 4:21:39 PM C:\Users\hillm\Documents\WORK\PROJECTS\2022_03_SHELFOLOGY SHOP EXTENSION\REVIT\2022_03_SHELFOLOGY SHOP EXPANSION_v22_2023 07 22.rvt A501 DETAILS 2022_03 SHELFOLOGY SHOP EXPANSION - PHASE 2 156 N 2ND E REXBURG, ID 83440 DOOR ASSEMBLY DOOR MATERIAL FRAME MATERIAL HARDWAR E GROUP REMARKSNU M B E R LOCATION TY P E DIMENSIONS FI N I S H MA T E R I A L FI N I S H WI D T H HE I G H T TH I C K N E S S 110-A FULFILLMENT H 3' - 0" 7' - 0" 0' - 1 3/4" 110-B FULFILLMENT B 10' - 0" 10' - 0" 0' - 1 1/2" 111 FULFILLMENT H 3' - 0" 7' - 0" 0' - 1 3/4" SCALE:1" = 1'-0" EXTERIOR WALL CONNECTION 1 SCALE:1" = 1'-0" PARTION BASE CONDITION 2 SCALE:1" = 1'-0" PARTION TOP CONDITION 3 SCALE:1" = 1'-0" ROOF CONNECTION 4 1. CONTRACTOR TO PROVIDE COMPLETE DOOR/HARDWARE PACKAGE TO FUNCTION AS INDICATED. 2. ALL HARDWARE TO MEET TITLE 24 AND ACCESSIBILITY REQUIREMENTS. 3. CONTRACTOR TO FIELD VERIFY CONDITION, HAND, THROAT SIZE AND WORKABILITY OF ALL DOORS AND HARDWARE; REPAIR OR REPLACE AS REQUIRED. 4. HINGES AT RATED ASSEMBLIES SHALL BE BALL BEARING. 5. DOOR AND GATE OPENING FORCE. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS (11B-404.2.9): 1. INTERIOR HINGED DOORS AND GATES: 5 LBS MAX 2. SLIDING OR FOLDER DOORS: 5 LBS MAX 3. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 LBS 4. EXTERIOR HINGED DOORS: 5 LBS MAX 6. LOCK CYLINDERS AND KEYS SHALL BE COORDINATED WITH TENANT AND BUILDING OWNER. 7. SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE (11B-404.2.10) 8. ALL GLAZING SHALL BE TEMPERED, ALL EXPOSED EDGES SHALL BE POLISHED. GLAZING WITHIN A 24" ARC OF EITHER SIDE OF DOORS MUST BE OF SAFETY GLAZING MATERIAL (CBC SEC. 2406). 9. OPERABLE PARTS OF DOOR HARDAWRE SHALL BE 34 INCHES MINIMUM AND 44 INCHES MAXIMUM ABOVETHE FINISH FLOOR OR GROUND. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 LBS (11B-309.4, 11B-404.2.7) 10. TRIM THE BOTTOMS OF DOORS TO CLEAR THE TOP OF FINISHED FLOOR, AS APPLICABLE, BY 1/4" INCH MINIMUM UON. VERIFY SLAB CONDITIONS. TRIM EACH DOOR TO FIT CONDITION. WHERE VARIATIONS IN FLOOR ELEVATION EXIST, DOORS SHALL BE ORDERED WITH BOTTOM STILE SIZED TO ACCOMMODATE THESE UNDERCUT CONDITIONS. 11. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES. 12. DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MAXIMUM DOOR NOTES SCALE:3" = 1'-0" EXTERIOR HM DOOR HEAD 6 SCALE:3" = 1'-0" EXTERIOR HM DOOR SILL 7 QUANTITY DESCRIPTION MODEL NUMBER FINISH MFR HARDWARE GROUP NO. 1 6 HINGE 3CB1 4.5 X 4.5 652 IVE 1 LOCKSET L9050-03N 626 SCH 2 SURFACE CLOSER 4040XP 689 LCN 1 THRESHOLD 325 AL NGP 2 KICKPLATE 8400 10" X 2" LDW B-CS 630 IVE 2 FLOOR STOP FS436 626 IVE 2 GASKETING 188S-BK S-BK ZER SCALE:3" = 1'-0" DOOR JAMB/ TYPICAL 8 A 12/08/2020 PLAN CHECK CORRECTIONS 1 7/20/2022 REVISION 1 1 SCALE:3" = 1'-0" WINDOW - JAMB 5 SCALE:3" = 1'-0" WINDOW - SILL AND HEAD 9