HomeMy WebLinkAboutFS PLANS - 22-00821 - Shelfology - AdditionN 2ND E. SRC IDAHO STATE FIRE MARSHAL'S OFFICE FIRE SPRINKLER PLAN REVIEW ACCEPTED 05/29/2024 8 6 24 0 8 16 24 S101 S102 S103 S104 S105 S106 S107 S108S109 S110 019 009 008 236 S201 S202 S203S204 S205 S206S207 S208 S209 004 055 056 016 8 6 24 0 8 16 24 Design Area Density: Calculations using Method Occupancy Classification: Design Area System Additional Outside Hose: Design Area Size: Notes: 1 Wet Fab Floor Demand Hazen-Williams OGII 0.2 250 1008 QR Modified This system as shown on company print no dated for at contract no is designed to discharge at a rate of a maximum area of when supplied with water at a rate of Occupancy classification: Commodity classification: Maximum storage height: Storage arrangement: Number of heads flowing: System Type: Maximum velocity: Flow from In-Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: Calculation results for Design Area gpm/ft² (L/min/m²) of floor area over - Surplus Pressure at Source: Pressure Required at Source: Pressure Available at Source: at at the base of the riser. Hose stream allowance of is included in the above. 1 Fab Floor Shelfology 5.1.2024 Shelfology 156 N 2nd E, Rexburg, ID 83440 24-201 0.2 1008 ft²307.9 gpm 67.9 psi OGII 10 Wet 22.31 ft/s 0 gpm 307.9 gpm 0 gpm 0 gpm 0 gpm 307.9 gpm 250 gpm 557.9 gpm 67.9 psi 77.6 psi 9.7 psi Design Area Density: Calculations using Method Occupancy Classification: Design Area System Additional Outside Hose: Design Area Size: Notes: 2 Wet Fab Floor Demand Hazen-Williams OGII 0.2 250 963 QR Modified This system as shown on company print no dated for at contract no is designed to discharge at a rate of a maximum area of when supplied with water at a rate of Occupancy classification: Commodity classification: Maximum storage height: Storage arrangement: Number of heads flowing: System Type: Maximum velocity: Flow from In-Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: Calculation results for Design Area gpm/ft² (L/min/m²) of floor area over - Surplus Pressure at Source: Pressure Required at Source: Pressure Available at Source: at at the base of the riser. Hose stream allowance of is included in the above. 2 Fab Floor Shelfology 5.1.2024 Shelfology 156 N 2nd E, Rexburg, ID 83440 24-201 0.2 963 ft²246.7 gpm 40.1 psi OGII 9 Wet 16.17 ft/s 0 gpm 246.7 gpm 0 gpm 0 gpm 0 gpm 246.7 gpm 250 gpm 496.7 gpm 40.1 psi 78.1 psi 38 psi IDAHO STATE FIRE MARSHAL'S OFFICE FIRE SPRINKLER PLAN REVIEW ACCEPTED 05/29/2024