HomeMy WebLinkAboutARCHITECTUAL PLANS - 22-00821 - Shelfology - Addition© Two Crows Collaboratve Date Description Project Name Project Number Description Scale Seal / Signature 2022 Tel 854.429.335530 STEPPING STONE WAY BLUFFTON, SC 29910 7/22/2023 12:51:15 PM C:\Users\hillm\Documents\WORK\PROJECTS\2022_03_SHELFOLOGY SHOP EXTENSION\REVIT\2022_03_SHELFOLOGY SHOP EXPANSION_v22_2023 07 22.rvt A001 GENERAL INFORMATION 2022_03 SHELFOLOGY SHOP EXPANSION - PHASE 2 156 N 2ND E REXBURG, ID 83440 SHEET INDEX -ARCHITECTURAL ADDRESS: FLOOR, SUITE: AREA OF WORK: 156 N 2ND E REXBURG, ID 83440 CONSTRUCTION TYPE: NUMBER OF STORIES: OCCUPANCY: CODES / REGULATIONS: VB -FULLY SPRINKLED 1 NEW: F2 (OCCUPANT LOAD: SHIPPING (300 GROSS) = 4 ; EXISTINGS: F-2 (OCCUPANTS = 80); TOTAL = 84 2018 IBC, 2017 NEC, 2018 IMC, 2018 IECC, 2018 EBC PROJECT INFORMATION PROJECT TEAM LOCATION MAP 1 REVIEW OF CONTRACT DOCUMENTS AND FIELD CONDITIONS BY CONTRACTOR. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS WITH EACH OTHER AND WITH AS-BUILT DRAWINGS PROVIDED BY THE OWNER AND SHALL AT ONCE REPORT TO THE ARCHITECT ERRORS, INCONSISTENCIES, OR OMISSIONS. THE CONTRACTOR SHALL TAKE FIELD MEASUREMENTS AND VERIFY FIELD CONDITIONS. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR AND HAS CONTROL OVER CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES, AND FOR COORDINATING ALL PORTIONS OF THE WORK. 2 INTENT OF CONTRACT DOCUMENTS. THE INTENT OF THE CONTRACT DOCUMENTS IS TO ALLOW FOR THE PERFORMANCE OF THE WORK. EVERY ITEM NECESSARILY REQUIRED MAY NOT BE SPECIFICALLY MENTIONED OR SHOWN. UNLESS EXPRESSLY STATED, ALL SYSTEMS AND EQUIPMENT SHALL BE COMPLETED AND APPROPRIATELY OPERABLE. FURNISH AND INSTALL ALL SPECIFIED AND APPROPRIATE ITEMS, AND ALL INCIDENTAL, ACCESSORY, AND OTHER ITEMS NOT SPECIFIED BUT REQUIRED FOR A COMPLETE AND FINISHED ASSEMBLY. 3 DEFECTIVE WORK. NO WORK DEFECTIVE IN WORKMANSHIP OR QUALITY OR DEFICIENT IN ANY REQUIREMENTS OF THE CONTRACT DOCUMENTS WILL BE ACCEPTABLE DESPITE THE ARCHITECT'S FAILURE TO DISCOVER OR POINT OUT DEFECTS OR DEFICIENCIES DURING CONSTRUCTION. DEFECTIVE WORK REVEALED WITHIN THE TIME REQUIRED BY GUARANTEES SHALL BE REPLACED BY WORK CONFORMING TO THE INTENT OF THE CONTRACT. NO PAYMENT, EITHER PARTIAL OR FINAL, SHALL BE CONSTRUED AS AN ACCEPTANCE OF DEFECTIVE WORK OR IMPROPER MATERIALS. 4 FIREPROOFING. PATCH AND REPAIR ALL FIREPROOFING DAMAGE INCURRED DURING DEMOLITION AND/OR CONSTRUCTION. FIREPROOF AS REQUIRED BY CODE ALL NEW PENETRATIONS GENERATED BY THE WORK DESCRIBED IN THESE DOCUMENTS. 5 AS-BUILT DRAWINGS. DURING THE COURSE OF CONSTRUCTION, ACTUAL LOCATIONS OF CONSTRUCTION ITEMS DENOTED IN THE CONSTRUCTION DOCUMENTS SHALL BE INDICATED TO SCALE IN CONTRASTING INK ON THE DRAWINGS FOR ALL RUNS OF MECHANICAL, SPRINKLER, PLUMBING, AND ELECTRICAL WORK; INCLUDING SITE UTILITIES AND CONCEALED DEVIATIONS FROM THE DRAWINGS. UPON COMPLETION OF THE PROJECT, THE ARCHITECT WILL PROVIDE THE CONTRACTOR WITH A REPRODUCIBLE SET OF ORIGINAL DOCUMENTS FOR "AS-BUILT" DOCUMENTATION. THIS SET SHALL BE CONSPICUOUSLY MARKED "AS-BUILTS" AND DELIVERED TO THE ARCHITECT. 6 CONTRACTOR RESPONSIBILITY. IT IS INTENDED THAT THE CONTRACTOR PROVIDE A COMPLETE JOB AND ANY OMISSIONS IN THESE NOTES OR IN THE OUTLINE OF WORK SHALL NOT BE CONSTRUED AS RELIEVING THE CONTRACTOR OF SUCH RESPONSIBILITIES IMPLIED BY SCOPE OF WORK EXCEPT FOR ITEMS SPECIFICALLY NOTED. 7 UNENFORCEABLE WORK. SHOULD ANY PORTION OF THE CONTRACT DOCUMENTS PROVE TO BE, FOR WHATEVER REASONS, UNENFORCEABLE, SUCH UNENFORCEABILITY SHALL NOT EXTEND TO THE REMAINDER OF THE CONTRACT NOR SHALL IT VOID ANY OTHER PROVISIONS OF THE CONTRACT. 8LIENS. THROUGHOUT THE DURATION OF THE PROJECT, THE CONTRACTOR SHALL REFRAIN FROM ACTIONS THAT COULD LEAD TO THE FILING OF CLAIMS OF LIEN BY SUBCONTRACTORS, SUPPLIERS OF MATERIALS, LABOR, SERVICE, EQUIPMENT, OR ANY OTHER INDIVIDUAL OR COMPANY SO ENTITLED UNDER GOVERNING LAWS AND REGULATIONS, UNLESS REASONABLE AND JUSTIFIABLE CAUSE CAN BE SHOWN. APPROVAL FOR PAYMENT SHALL BE CONTINGENT UPON THE CONTRACTOR'S OBTAINING AND FURNISHING TO THE ARCHITECT SIGNED RELEASES FROM SUCH INDIVIDUALS OR COMPANIES. 9 COORDINATION OF THE WORK. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW AND VERIFICATION OF CONTRACT DOCUMENTS, FIELD CONDITIONS, AND DIMENSIONS FOR ACCURACY AND CONFIRMING THAT WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY QUESTIONS REGARDING THESE OR OTHER COORDINATION ISSUES, THE CONTRACTOR SHALL SUBMIT THEM IN WRITING TO THE ARCHITECT AND IS RESPONSIBLE FOR OBTAINING A WRITTEN CLARIFICATION FROM THE ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION, OR RELATED WORK. 10 WORK SHOULD COMPLY WITH APPLICABLE CODES. EXECUTE WORK IN ACCORDANCE WITH ANY AND ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES, MANUFACTURER'S RECOMMENDATIONS, AND TRADE AND REFERENCE STANDARDS, INCLUDING BUT NOT LIMITED TO: FEDERAL, STATE, LOCAL/MUNICIPAL CODES, IBC, UBC, SEISMIC CODES, NEC, NFPA, ASMC, AND UMC (LATEST ENFORCED EDITIONS). 11 DIMENSIONS. DO NOT SCALE DRAWINGS; DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN OVER PLANS AND ELEVATIONS. LARGE SCALE DETAILS SHALL GOVERN OVER SMALL SCALE DETAILS. WRITTEN SPECIFICATIONS SHALL GOVERN OVER ALL. 12 CLARIFICATIONS. CLARIFY ALL DISCREPANCIES RELATIVE TO CONSTRUCTION DOCUMENTS, SPECIFICATIONS, AND FIELD CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. 13 SUBSTITUTIONS. THERE SHALL BE NO SUBSTITUTION OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED. WHERE THE TERM "OR EQUAL" IS USED, THE ARCHITECT ALONE SHALL DETERMINE EQUALITY BASED UPON INFORMATION SUBMITTED BY THE CONTRACTOR, CLEARLY IDENTIFIED AS A "REQUEST FOR SUBSTITUTION". CONTRACTOR SHALL ALSO LIST CREDIT TO THE CLIENT FOR USE OF SUBSTITUTION. CONSENT OF THE ARCHITECT/OWNER. 14 DRAWING DISTRIBUTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISTRIBUTION OF DRAWINGS TO ALL TRADES UNDER THEIR JURISDICTION. 15 CHANGES IN THE WORK. DO NOT PROCEED WITH ANY WORK REQUIRING ADDITIONAL COMPENSATION BEYOND THE CONTRACT AMOUNT WITHOUT WRITTEN AUTHORIZATION FROM THE OWNER. FAILURE TO OBTAIN AUTHORIZATION SHALL INVALIDATE ANY CLAIM FOR EXTRA COMPENSATION. 16 EXISTING WORK. ALL INSTALLED PLUMBING, MECHANICAL, AND ELECTRICAL EQUIPMENT SHALL OPERATE QUIETLY AND FREE OF VIBRATION. 17 PUNCH LIST. UPON COMPLETION OF THE WORK BY THE CONTRACTOR, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF SUCH COMPLETION. THE ARCHITECT SHALL ATTEND THE PUNCH LIST WALK THROUGH CONDUCTED BY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR SHALL PREPARE AND DISTRIBUTE A LIST OF ITEMS TO BE FINISHED OR COMPLETED PRIOR TO THIS WALK THROUGH. THE GENERAL CONTRACTOR SHALL TAKE NOTES AND PREPARE A LIST OF FINAL PUNCH ITEMS TO BE COMPLETED OR CORRECTED AS A RESULT OF THIS WALK THROUGH. THIS PUNCH LIST IS TO BE PROMPTLY DISTRIBUTED BY THE GENERAL CONTRACTOR TO THE TENANT, OWNER AND ARCHITECT. 18 MATERIALS. ALL MATERIALS SHALL BE NEW, UNUSED, AND OF THE HIGHEST QUALITY IN EVERY RESPECT, UNLESS NOTED OTHERWISE. MANUFACTURED MATERIALS AND EQUIPMENT SHALL BE INSTALLED AS PER MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS, UNLESS NOTED OTHERWISE. 19 INSURANCE. THE CONTRACTOR AND SUBCONTRACTORS SHALL PURCHASE AND MAINTAIN CERTIFICATIONS OF INSURANCE WITH RESPECT TO WORKERS COMPENSATION, PUBLIC LIABILITY, AND PROPERTY DAMAGE FOR THE LIMITS AS REQUIRED BY LAW, IN ADDITION TO THE TERMS OF THE OWNER'S CONTRACT, WHICHEVER IS GREATER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS IN CONNECTION WITH THE WORK. 20 EXISTING TENANTS. COORDINATE ALL WORK WITH BUILDING OWNER SO AS NOT TO DISTURB OR CAUSE DAMAGE TO ANY TENANT 21 COORDINATION. VERIFY IN THE FIELD THAT NO CONFLICTS EXIST WHICH WOULD PROHIBIT THE LOCATION OF ANY AND ALL MECHANICAL, TELEPHONE, ELECTRICAL, LIGHTING, PLUMBING, AND SPRINKLER EQUIPMENT (TO INCLUDE ALL REQUIRED PIPING, DUCTWORK, AND CONDUIT), AND THAT ALL REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE OF ABOVE EQUIPMENT ARE PROVIDED. 22 PROTECTION OF EXISTING WORK. PROVIDE PROTECTION TO ALL EXISTING FINISHES IN ALL SPACES WITHIN OR ADJACENT TO THE SCOPE OF WORK AND THE TENANT'S SPACE. THE CONTRACTOR SHALL PATCH, REFINISH, AND REPAIR ANY DAMAGE CAUSED BY HIM OR HIS SUBCONTRACTORS. MATCH EXISTING ADJACENT FINISH, OR AS NOTED HEREIN. 23 EXISTING DEFECTS. CORRECT ANY DEFECTS FOUND IN EXISTING BUILDING CONSTRUCTION WHICH AFFECTS THE SCOPE OF WORK. THIS INCLUDES BUT IS NOT LIMITED TO UNEVEN SURFACES AND FINISHES AT GYPSUM BOARD OR DAMAGED FIREPROOFING. PATCH AND REPAIR SURFACES TO MATCH ADJACENT, ADJOINING SURFACES. 1 OWNER ACKNOWLEDGES THAT GENSLER SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, PRESENCE HANDLING, REMOVAL, DISPOSAL, OR EXPOSURE OF PERSONS TO HAZARDOUS SUBSTANCES, MATERIALS, AND WASTES IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO: ASBESTOS, ASBESTOS PRODUCTS, PCB MOLD, OR OTHER TOXIC SUBSTANCES. 2 THE OWNER ACKNOWLEDGES THAT IT ACCEPTS RESPONSIBILITY FOR NOTIFYING THE APPROPRIATE FEDERAL, STATE, AND AUTHORITIES HAVING JURISDICTION FOR ANY DEMOLITION, CONSTRUCTION, OR REPAIR WORK. 3 ANY QUESTIONS THAT ARISE RELATED TO ASBESTOS SHALL BE REFERRED TO THE OWNER FOR RESOLUTION. GENSLER SHALL NOT BE REQUIRED TO DO ANY WORK NO RENDER ANY OPINIONS RELATED TO ASBESTOS. 4 THE OWNER SHALL RETAIN AN INDEPENDENT CONSULTANT WHO IS TRAINED AND EXPERIENCED IN IDENTIFICATION AND SURVEY OR EXISTING SITES PRIOR TO START OF DEMOLITION CONSTRUCTION. 5 ALL CONTRACTORS AND SUBCONTRACTORS SHALL REPORT THE PRESENCE OF ANY MATERIAL OR ASSEMBLY SUSPECTED TO CONTAIN ASBESTOS UPON DISCOVERY. THE WORK SHALL BE CARRIED OUT PER THE CONSULTANTS RECOMMENDATIONS. GENERAL NOTES HAZARDOUS MATERIALS NOTES OWNER / TENANT ADDRESS: TELEPHONE/FAX: CONTACT: EMAIL: ARCHITECT ADDRESS: TELEPHONE/FAX: CONTACT: EMAIL: GENERAL CONTRACTOR ADDRESS: TELEPHONE/FAX: CONTACT: EMAIL: MECHANICAL ENGINEER ADDRESS: TELEPHONE/FAX: CONTACT: EMAIL: 156 N 2ND E REXBURG, ID 83440 949.244.1083 KEVIN ANDERSON KEVIN@SHELFOLOGY.COM SHELFOLOGY 30 STEPPING STONE WAY BLUFFTON, SC 29910 (435)764-3169 MIKE HILL MIKE@TWOCROWSCOLLAB.COM TWO CROS COLLABORATIVE - - - - - 5257 WILD DUNES LN IDAHO FALLS, ID 83404 (208)709-3111 MARK OWENS MOWENS@XLENGINEERING.NET XL ENGINEERING PLUMBING ENGINEER ADDRESS: TELEPHONE/FAX: CONTACT: EMAIL: - - - - - NEW: 908 SF; EXISTING BUILDING: 15,113 = TOTAL: 16,021 (18,000 SF ALLOWED) Sheet Number Sheet Name PL A N C H E C K - 1 0 / 2 2 / 2 0 2 2 PL A N C H E C K C O R R E C T I O N S - 1 2 / 1 2 / 2 0 2 2 1_GENERAL PROJECT INFORMATION A000 COVER SHEET O A001 GENERAL INFORMATION O O A002 GENERAL NOTES O A003 SYMBOLS O A004 ABBREVIATIONS O A005 ACCESSIBILITY DETAILS O A006 ACCESSIBILITY DETAILS O A007 COM CHECK O 2_ARCHITECTURAL A100 SITE PLAN O A103 FLOOR PLAN - LVL 1 FULFILLMENT O A203 REFLECTED CEILING PLAN - LVL 1 FULFILLMENT O A301 SECTIONS - FULFILLMENT O A401 ELEVATIONS O A501 DETAILS O O A502 CEILING DETAILS O O 3_STRUCTURAL S1.0 GENERAL STRUCTURAL NOTES O S1.1 TYPICAL DETAILS O S1.2 TYPICAL DETAILS O S2.0A FULFILLMENT FOUNDATION O S2.1A FULFILLMENT ROOF FRAMING O S3.0 FOUNDATION DETAILS O S4.0 FRAMING DETAILS O S5.0 WALL ELEVATION DETAILS O 4_ELECTRICAL E00 ELECTRICAL SYMBOLS AND ABBREVIATIONS O E01 ENERGY COMPLIANCE FORMS O E11 LIGHTING POWER PLANS - FULFILLMENT O STRUCTURAL ADDRESS: TELEPHONE/FAX: CONTACT: EMAIL: 1020 E. LINCOLN ROAD IDAHO FALLS, ID 83404 (208)227-8404 BRIGHAM CHRISTENSEN BRIGHAMC@FROSTSTRUCTURAL .COM FROST STRUCTURAL ENGINEERING SCOPE OF WORK:FULLFILLMENT EXPANSION. SITE LOCATION 24 TERMINOLOGY. TYPICAL OR TYP MEANS IDENTICAL FOR ALL SIMILAR CONDITIONS, UNLESS NOTED OTHERWISE. SIMILAR OR SIM MEANS COMPARABLE CHARACTERISTICS TO THE CONDITION NOTED. VERIFY DIMENSIONS AND ORIENTATION ON PLAN. VERIFY OR VER MEANS TO ASCERTAIN AND CONFIRM APPLICATION WITH ARCHITECT. 25 FURNITURE. FURNITURE SHOWN IS FOR REFERENCE ONLY AND INSTALLED BY OTHERS, UNLESS NOTED OTHERWISE. 26 FILE CABINETS. FILE CABINETS, AS SHOWN ON DRAWINGS, ARE SUPPLIED BY OTHERS. COORDINATE FILE SIZE(S) WITH FURNITURE INSTALLER FOR REQUIRED CLEARANCES. 27 CLEANING. PROVIDE STRICT CONTROL OF JOB CLEANING AND PREVENT DUST AND DEBRIS FROM MIGRATING FROM CONSTRUCTION AREA. 28 ADJACENT SPACES. CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING OF ACCESS INTO ADJACENT TENANT SPACES WITH THE BUILDING MANAGEMENT AS REQUIRED FOR PRICING AND EXECUTION OF THE WORK. 29 EXISTING CONDITIONS. CONTRACTOR SHALL THOROUGHLY EXAMINE THE PREMISES AND SHALL BASE HIS BID ON THE EXISTING CONDITIONS, NOTWITHSTANDING ANY INFORMATION SHOWN OR NOT INDICATED ON THE CONTRACT DOCUMENTS. 30 CONTRACT DOCUMENTS. ALL CONTRACT DOCUMENTS ARE COMPLEMENTARY AND WHAT IS CALLED FOR BY ANY WILL BE AS BINDING AS IF CALLED FOR BY ALL. ALL WORK SHOWN OR REFERRED TO ON ANY CONTRACT DOCUMENT SHALL BE PROVIDED AS THOUGH THEY ARE ON ALL RELATED DOCUMENTS. 31 CONTRACTOR RESPONSIBILITY TO NOTIFY ARCHITECT. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE ARCHITECT OF ANY CONFLICTS HEREIN - EITHER APPARENT OR OBVIOUS - PRIOR TO THE START OF NEW WORK ON THAT ITEM, OR BEAR THE RESPONSIBILITY OF CORRECTING SUCH WORK AS DIRECTED BY THE ARCHITECT. 32 DUPLICATION OF DOCUMENTS. ALL DRAWINGS AND WRITTEN MATERIAL HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT/OWNER AND THE SAME MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT/OWNER. 33 DETAIL REFERENCE. REFER TO A12 SHEETS SERIES FOR DETAILS NOT CROSS REFERENCED FOR ALL THE CONDITIONS OF PENETRATION THROUGH FIRE RATED ASSEMBLIES AND ACOUSTICAL PARTITIONS. 34 EXISTING PENETRATIONS. ALL PENETRATIONS TO THE FLOOR/CEILING ASSEMBLY SHALL BE GROUTED SOLID WITH A QUICK-SET CONCRETE FILLER. THE SLAB BETWEEN THE MECHANICAL EQUIPMENT ROOM AND THE TENANT SPACE SHALL BE ACOUSTICALLY SEALED AIRTIGHT. 35 SHOP DRAWINGS AND SUBMITTALS. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO REVIEW ALL SUBMITTALS AND SHOP DRAWINGS FOR APPROPRIATENESS AND COMPLIANCE WITH THE CONTRACT DOCUMENTS PRIOR TO SENDING SHOP DRAWINGS TO THE ARCHITECT OR ENGINEER FOR REVIEW. A STAMP OR STATEMENT TESTIFYING THE CONTRACTOR HAS REVIEWED THE SHOP DRAWINGS, INCLUDING THE DATE REVIEWED, MUST BE AFFIXED TO THE FIRST PAGE OF EACH SUBMITTAL. 36 IF ANY WORK IS PERFORMED PRIOR TO PROPER CLARIFICATION, CONTRACTOR SHALL CORRECT CONFLICTING WORK AT CONTRACTORS EXPENSE AT NO ADDITIONAL COST TO THE OWNER, TENANT OR ARCHITECT. 37 LANDINGS AND CROSS SLOPE OF SIDEWALK NOT TO EXCEED 2% CROSS SLOPE. 38 ALL EXIT SIGNS TO COMPLY SECCTION 1008 AND 1013. 39 ALL WELDS AND BOLTED STEEL CONNECTION REQUIRE SPECIAL INSPECTIONS. A 12/08/2020 PLAN CHECK CORRECTIONS 1 7/20/2022 REVISION 1 PLUMBING FIXTURES TOILETS 1:100 M/F LAVATORIES 1:100 M/F UTILITY SINKS 2 REQ (M=1 F=1) 2 REQ (M=1 F=1)1 REQ 5 EXISTING UNISEX 5 EXISTING UNISEX 1 EXISTING HAZARDOUS MATERIALS NOTES 1 IT IS UNDERSTOOD THAT PLANS FOR THE PROJECT HAVE, AT THIS TIME, BEEN REVIEWED FOR COMPLIANCE WITH ALL APPLICABLE STATE AND CITY REGULATIONS, AND THAT THE PROJECT AS A WHOLE HAS BEEN APPROVED BY THE CITY, WITH THE EXCEPTION OF THE DEFERRED ITEMS LISTED. 2 I/WE UNDERSTAND THAT I/WE WILL NOT BE AUTHORIZED ANY INSPECTION OF THE DEFERRED ITEMS PROPOSED PRIOR TO THE SUBMITTAL AND APPROVAL OF PLANS AND/OR CALCULATIONS FOR THOSE DEFERRED ITEMS. 3 COMPLETE PLANS AND SPECIFICATIONS FOR ALL FIRE EXTINGUISHING SYSTEMS, INCLUDING AUTOMATIC SPRINKLER AND STANDPIPE SYSTEMS AND OTHER SPECIAL FIRE EXTINGUISHING SYSTEMS AND RELATED APPURTENANCES SHALL BE SUBMITTED TO THE CITY OF SANTA ANA FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION 4 COMPLETE PLANS AND SPECIFICIATIONS FOR ALL FIRE ALARM SYSTEMS SHALL BE SUBMITTED TO THE CITY OF---UPDATE--- DEVELOPMENT SERVICES FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 1 1 TYPE "A" SEE SCHEDULE SE E S C H E D U L E SOLID CORE WOOD DOOR HARDWARE SET - 1: LOCKSET A. HAGAR MORTISE LOCKSET, #3410 FINISH TO MATCH BLDG STD. 40" A.F.F. TO CENTERLINE OF LEVER. B. 4 1/2" X 4 1/2" HAGER BB-1279 FINISH TO MATCH LEVER, BUTT HINGES TWO PAIR. 3' - 0 " 2'-0" 4' - 0 " TYPE "AA" FIXED WINDOW 1- 2- Level 1 0' -0" A 3" SPRAY INSULATION R-18 CORRUGATED MTL PANEL TO MATCH EXISTING STRUCTURAL WOOD FRAMING, REFER TO STRUCTURAL MTL BASE ANGLE FLASHING 5/8" TYPE GYPSUM Level 1 0' -0" 5/8" GYPSUM BOARD 2X6 SILL PLATE 2X6 STUD WALL 11/2" PLYWOOD 2X6 JOIST 16" OC 2X6 JOIST RIM JOIST 2X6 DOUBLE HEADER 2X6 STUD FRAMING 16" OC 5/8" GYPSUM BOARD STEEL SUPPORT ANGLE 2X6 JOIST RIM JOIST 3" SPRAY INSULATION R-18 STRUCTURAL WOOD FRAMING, REFER STRUCTURAL CORRUGATED METAL PANELS TO MATCH EXISTING A CORRUGATED MTL PANEL TO MATCH EXISTING 3" SPRAY INSULATION R-18 CORRUGATED MTL PANEL TO MATCH EXISTING STRUCTURAL WOOD FRAMING, REFER TO STRUCTURAL GLULAM BEAM REFER TO STRUCTURAL 4" SPRAY INSULATION R-24 5/8" TYPE GYPSUM 0' - 2" 0' - 0 5 / 8 " 0' - 2"VARIES 0' - 0 1/2" 0' - 2 " 08 11 13.B00 STEEL FRAME 08 11 13.A00 STEEL DOOR EXTERIORINTERIOR 5/8" TYPE C GYPSUM (4HR FIRE RATED) STANDARD 2X4 WOOD STUD 0' - 2"0' - 2"VARIES 1/2" TRANSITION MUST COMPLY WITH ACCESSIBLE TRANSITION REQUIREMENTS. SEE ACCESSIBILITY DETAILS. DOOR AND JAMB BEYOND EXTERIORINTERIOR 08 11 13.A00 STEEL DOOR 08 41 13.O00 WEATHER SWEEP 08 41 13.N00 THRESHOLD 07 27 26.A00 ? 09 24 00.A00 PORTLAND CEM PLAS 05 40 00.L01 GLASS-MAT GYP SHEATHING BOARD 05 40 00.C00 STEEL STUD 1" T Y P 0' - 0 7 / 8 " 0' - 2 " 0' - 0 5/8" 0' - 2 " VA R I E S 0' - 0 1 / 2 " 0' - 2"COORD WITH EXTERIOR WALL +/- 0' - 5 1/4" 08 11 13.B00 STEEL FRAME 08 11 13.A00 STEEL DOOR EXTERIOR INTERIOR © Two Crows Collaboratve Date Description Project Name Project Number Description Scale Seal / Signature 2022 Tel 854.429.335530 STEPPING STONE WAY BLUFFTON, SC 29910 As indicated 7/22/2023 12:53:05 PM C:\Users\hillm\Documents\WORK\PROJECTS\2022_03_SHELFOLOGY SHOP EXTENSION\REVIT\2022_03_SHELFOLOGY SHOP EXPANSION_v22_2023 07 22.rvt A501 DETAILS 2022_03 SHELFOLOGY SHOP EXPANSION - PHASE 2 156 N 2ND E REXBURG, ID 83440 DOOR ASSEMBLY DOOR MATERIAL FRAME MATERIAL HARDWAR E GROUP REMARKSNU M B E R LOCATION TY P E DIMENSIONS FI N I S H MA T E R I A L FI N I S H WI D T H HE I G H T TH I C K N E S S 110-A FULFILLMENT H 3' - 0" 7' - 0" 0' - 1 3/4" 110-B FULFILLMENT B 10' - 0" 10' - 0" 0' - 1 1/2" 111 FULFILLMENT H 3' - 0" 7' - 0" 0' - 1 3/4" SCALE:1" = 1'-0" EXTERIOR WALL CONNECTION 1 SCALE:1" = 1'-0" PARTION BASE CONDITION 2 SCALE:1" = 1'-0" PARTION TOP CONDITION 3 SCALE:1" = 1'-0" ROOF CONNECTION 4 1. CONTRACTOR TO PROVIDE COMPLETE DOOR/HARDWARE PACKAGE TO FUNCTION AS INDICATED. 2. ALL HARDWARE TO MEET TITLE 24 AND ACCESSIBILITY REQUIREMENTS. 3. CONTRACTOR TO FIELD VERIFY CONDITION, HAND, THROAT SIZE AND WORKABILITY OF ALL DOORS AND HARDWARE; REPAIR OR REPLACE AS REQUIRED. 4. HINGES AT RATED ASSEMBLIES SHALL BE BALL BEARING. 5. DOOR AND GATE OPENING FORCE. THE FORCE FOR PUSHING OR PULLING OPEN A DOOR OR GATE OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS (11B-404.2.9): 1. INTERIOR HINGED DOORS AND GATES: 5 LBS MAX 2. SLIDING OR FOLDER DOORS: 5 LBS MAX 3. REQUIRED FIRE DOORS: THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY, NOT TO EXCEED 15 LBS 4. EXTERIOR HINGED DOORS: 5 LBS MAX 6. LOCK CYLINDERS AND KEYS SHALL BE COORDINATED WITH TENANT AND BUILDING OWNER. 7. SWINGING DOOR AND GATE SURFACES WITHIN 10 INCHES OF THE FLOOR OR GROUND MEASURED VERTICALLY SHALL HAVE A SMOOTH SURFACE ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE (11B-404.2.10) 8. ALL GLAZING SHALL BE TEMPERED, ALL EXPOSED EDGES SHALL BE POLISHED. GLAZING WITHIN A 24" ARC OF EITHER SIDE OF DOORS MUST BE OF SAFETY GLAZING MATERIAL (CBC SEC. 2406). 9. OPERABLE PARTS OF DOOR HARDAWRE SHALL BE 34 INCHES MINIMUM AND 44 INCHES MAXIMUM ABOVETHE FINISH FLOOR OR GROUND. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 LBS (11B-309.4, 11B-404.2.7) 10. TRIM THE BOTTOMS OF DOORS TO CLEAR THE TOP OF FINISHED FLOOR, AS APPLICABLE, BY 1/4" INCH MINIMUM UON. VERIFY SLAB CONDITIONS. TRIM EACH DOOR TO FIT CONDITION. WHERE VARIATIONS IN FLOOR ELEVATION EXIST, DOORS SHALL BE ORDERED WITH BOTTOM STILE SIZED TO ACCOMMODATE THESE UNDERCUT CONDITIONS. 11. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES. 12. DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MAXIMUM DOOR NOTES SCALE:3" = 1'-0" EXTERIOR HM DOOR HEAD 6 SCALE:3" = 1'-0" EXTERIOR HM DOOR SILL 7 QUANTITY DESCRIPTION MODEL NUMBER FINISH MFR HARDWARE GROUP NO. 1 6 HINGE 3CB1 4.5 X 4.5 652 IVE 1 LOCKSET L9050-03N 626 SCH 2 SURFACE CLOSER 4040XP 689 LCN 1 THRESHOLD 325 AL NGP 2 KICKPLATE 8400 10" X 2" LDW B-CS 630 IVE 2 FLOOR STOP FS436 626 IVE 2 GASKETING 188S-BK S-BK ZER SCALE:3" = 1'-0" DOOR JAMB/ TYPICAL 8 A 12/08/2020 PLAN CHECK CORRECTIONS 1 7/20/2022 REVISION 1 1 4" CONCRETE SLAB ON GRADE (W/ #4 AT 36" O.C. EACH WAY CENTERED IN SLAB THICKNESS AT CONTRACTOR'S OPTION) OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME CONCRETE SLAB ON GRADE WF18/W1 EX I S T I N G F O O T I N G WF 1 8 / W 1 F30 F30 51'-9" 5'-3"10'-0"1'-8"2'-6"2'-2"2'-8"27'-6" 19 ' - 0 " 16'-103 4"16'-0"18'-03 4" 18'-6"16'-0"17'-3" 41 4"51 4" SC2 SC2 SC2 F48A SC2 SC2 SC2 1 1 SC2 F48A 2 2 SC2 F36 102 102 106 106 403 107107109 402 402 108 108 109 108 SCALE: FULFILLMENT FOUNDATION PLAN 1/4" = 1'-0" 109 STEEL COLUMN AT FOUNDATION NO SCALE KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.CONT 2x PT SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 9.EDGE NAILING, SEE SHEARWALL SCHEDULE 10.WALL SHEATHING AS OCCURS, SEE PLAN 3" CLR 3" CL R 7 6 2 5 4 3 10 9 1 8 208 NO SCALE KEYNOTES: 1.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 2.WOOD STUD WALL, SEE PLAN 3.WOOD BEAM, SEE PLAN 4.WOOD JOIST, SEE PLAN 5.ROOF SHEATHING, SEE PLAN 6.BOUNDARY NAILING, SEE PLAN 7.2x6 LADDER FRAMING AT 16" O.C. 8.(2) 16d NAILS AT 16" O.C. 9.NO SHEATHING SPLICE TO OCCUR IN THIS AREA 10.TJI BLOCKING AT 24" O.C. W/ 16d TOE NAILS AT BOTTOM 11.(4) 8d NAILS INTO EACH BLOCK 12.WALL SHEATHING AS OCCURS, SEE PLAN 13.EDGE NAILING, SEE SHEARWALL SCHEDULE 7 6 4 6 8 5 8 2'-0" MAX 9 10 8 11 3 1 2 1313 12 209 NO SCALE KEYNOTES: 1.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 2.WOOD STUD WALL, SEE PLAN 3.WOOD BEAM, SEE PLAN 4.WOOD JOIST W/ CLIP, SEE PLAN 5.ROOF SHEATHING, SEE PLAN 6.BOUNDARY NAILING, SEE PLAN 7.2x6 TAIL AT EACH JOIST W/ (2) 16d NAILS AT 6" O.C. STAGGERED 8.WEB STIFFENER TO RECEIVE 2x TAIL 9.2x4 BEVELED BLOCK W/ (6) 16d NAILS 10.2x BLOCKING BETWEEN EACH JOIST W/ A35 CLIP 11.WALL SHEATHING AS OCCURS, SEE PLAN 12.EDGE NAILING, SEE SHEARWALL SCHEDULE 7 4 65 2'-0" MAX 3 8 6 10 9 3'-0" 1 2 1212 11 212 NO SCALE 6 4 685 8 9 8 KEYNOTES: 1.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 2.WOOD STUD WALL, SEE PLAN 3.WOOD BEAM, SEE PLAN 4.WOOD JOIST, SEE PLAN 5.ROOF SHEATHING, SEE PLAN 6.BOUNDARY NAILING, SEE PLAN 7.2x6 LADDER FRAMING AT 16" O.C. 8.(2) 16d NAILS AT 16" O.C. 9.NO SHEATHING SPLICE TO OCCUR IN THIS AREA 10.WOOD JOIST W/ HANGER AND CLIP, SEE PLAN 11.TJI BLOCKING AT 24" O.C. W/ 16d TOE NAILS AT BOTTOM 12.(4) 8d NAILS INTO EACH BLOCK 13.2x BLOCKING W/ A35 CLIP BETWEEN EACH JOIST 14.2x BLOCKING W/ (4) 16d NAILS BETWEEN EACH JOIST 15.WALL SHEATHING AS OCCURS, SEE PLAN 16.EDGE NAILING, SEE SHEARWALL SCHEDULE 17.2x BOTTOM PLATE W/ 16d NAILS AT 6" O.C. 3 3 10 7 11 12 3 65 6 13 14 2'-0" MAX 1 2 16 15 1 1616 17 THE CONTRACTOR WANTS TO REMOVE THE WALL GIRTS AND CROSS BRACING AND FRAME WALLS WITH STUDS AND WALL SHEATHING. ALL SHEATHING TO BE 7/16" THICK AND NAILED AT 6" O.C. AT PANEL EDGES AND AT 12" O.C. IN THE FIELD. ALL NAILS TO BE 8d. UPDATE DETAILS THAT ARE AFFECTED BY FRAMING CHANGE 07/19/2023 15/32" APA RATED ROOF SHEATHING W/ 8d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. TYPICAL ROOF SHEATHING: 15/32" APA RATED ROOF SHEATHING W/ 8d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. TYPICAL ROOF SHEATHING: P4 P4 SC2 SC2SC2 1 1 3 2 4 4 WJ 2 WJ 2 WJ 2 WJ3 B4 B4 B6 (CONT) B4 B4 B8 HIGHB8 B8 LOW B8 HIGH B8 LOW 210 208 209 213 213 211 212 5 TYP 214 SC2 SC2 SC2 SC2 302 6TYP 301 B8B8 B8 55 TYP 214 6TYP 5 SC2 SCALE: FULFILLMENT ROOF FRAMING PLAN 1/4" = 1'-0" THE CONTRACTOR WANTS TO REMOVE THE WALL GIRTS AND CROSS BRACING AND FRAME WALLS WITH STUDS AND WALL SHEATHING. ALL SHEATHING TO BE 7/16" THICK AND NAILED AT 6" O.C. AT PANEL EDGES AND AT 12" O.C. IN THE FIELD. ALL NAILS TO BE 8d. 07/19/2023