HomeMy WebLinkAboutPERSCRIPTIVE INSULATION REPORT - 23-00753 - Pebble Creek Townhomes - 6 Plex - Bldg 1City of Rexburg Building Department
Re: Prescriptive Insulation Path
Building Division
Office (208) 372-2166
Planning Division
Office(208)372-2167
To: City of Rexburg Building Department
From:
Contractor or Homeowner U
I will be following the prescriptive insulation path for climate zone 6 for the home located at
/-//r% 5r �1 �w��i i�i�� 64"?ram
Address
The prescriptive insulation values and u factors are shown below.
Table R402.1.2
Insulation and Fenestration Requirements by Components
R- Wood
Zone U-Factor U-FactoFrame
WallWall R-
Climate Fenestration Skylight749*
Floor R- Basement
Value WalValue l
Slab R-
&Value
Crawlspace
Value
Value
Depth
6 .30 .55 22 or
13+5*
30 15/19*
10, 4 ft
15/19*
*Notes : plus RS continuous insulation.
13-5, The first value is cavity and the second value is continuous. Therefore "13+5" means R13 cavity p
15119, The first value is continuous insulation and the second value is cavity insulation
R30 ceiling insulation may be used under certain conditions as per N1102.2.2
g=2Q -
Date
Signature