Loading...
HomeMy WebLinkAboutAPPROVED UPDATED PLANS - 23-00505 - Golden West Irrigation - InteriorDescription : Golden West Irrigation - Interior Address : 2300 S Hwy 191 Record Type : Madison County - Commercial Document Filename : UPDATED PLANS - 23-00505 - Golden West Irrigation - Interior-Reviewed-Corrections-Required.pdf Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Approved # 23-00505 Madison County - Commercial Approval of plans does not constitute approval of variance from code Powered by TCPDF (www.tcpdf.org) Author Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Don Allen Don.Allen@rexburg.org 208-372-2174 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Golden West Irrigation - Interior Address : 2256 S Hwy 191 Application Type : Document Filename : UPDATED PLANS - 23-00505 - Golden West Irrigation - Interior.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 1 Free Text Cody Jones : Building Open 1 2871 sq ft= 5.7 occupants Pg 1 Free Text Cody Jones : Building Open 1 1548 sq ft = 3.09 occupants Pg 1 Free Text Cody Jones : Building Open 1 3313 sq ft = 22 occupants Pg 1 Free Text Cody Jones : Building Open 1 Usable space under enclosed and unenclosed stairways to have minimum 1 hour fire resistance. Pg 1 Free Text Cody Jones : Building Open 1 VB Pg 1 Callout Cody Jones : Building Open 1 Handrails and Guards meet the requirements of IBC Sections 1014 and 1015 Pg 1 Free Text Alex Owens : Electrical Open 1 In conversation with Roy Jenkins on 8/10/23 he mentioned that the building will be fed from the subpanel of an adjacent building. The size of panel installed in this building will be 200 amps. This building will have receptacles for the office space. The rest of the building will be parts storage (mostly just lights). All electrical work must meet 2017 NEC standards. # 23-00505 Madison County - Commercial Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 08.21.2023 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments Pg 1 Callout Stan Crittenden : Fire Open 1 IFC 2018 903.2.9 (4) a S-1 fire area that stores commercial vehicle requires fire sprinklers after 5,000 sq. ft. Will this wall be a rated separation wall? Pg 2 Callout Kyle Baldwin : P&Z Open 2 6' wide sidewalks required between building and parking areas See development code section 6.00.090 Pg 2 Callout Kyle Baldwin : P&Z Open 2 Incorrect Street label Pg 2 Callout Kyle Baldwin : P&Z Open 2 Site Plan must include setback measurements Pg 2 Callout Kyle Baldwin : P&Z Open 2 Must provide parking stall dimensions Pg 2 Callout Kyle Baldwin : P&Z Open 2 Must show parcel lines Pg 2 Callout Kyle Baldwin : P&Z Open 2 Must provide distance between buildings Pg 2 Free Text Kyle Baldwin : P&Z Open 2 Please remove arial photo from background to make plan more legible Pg 2 Free Text Kyle Baldwin : P&Z Open 2 Must provide north indicator Pg 2 Free Text Kyle Baldwin : P&Z Open 2 Must show snow storage location/area calculations on Site Plan Report Date: 08.21.2023 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org) 3313 sq ft = 22 occupants V B H and rails and G uard s m e e t th e re quire m e nts of IB C S e ctions 10 14 and 10 15 IF C 20 18 9 0 3.2.9 (4 ) a S -1 fire are a th at store s com m e rcial v e h icle re quire s fire sprink le rs afte r 5 ,0 0 0 sq. ft. W ill th is w all b e a rate d se paration w all? 28 7 1 sq ft= 5 .7 occupants 15 4 8 sq ft = 3.0 9 occupants In conv e rsation w ith R oy J e nk ins on 8 /10 /23 h e m e ntione d th at th e b uild ing w ill b e fe d from th e sub pane l of an ad jace nt b uild ing . T h e siz e of pane l installe d in th is b uild ing w ill b e 20 0 am ps. T h is b uild ing w ill h av e re ce ptacle s for th e office space . T h e re st of th e b uild ing w ill b e parts storag e (m ostly just lig h ts). A ll e le ctrical w ork m ust m e e t 20 17 N E C stand ard s. U sab le space und e r e nclose d and une nclose d stairw ay s to h av e m inim um 1 h our fire re sistance . 6 ' w id e sid e w alk s re quire d b e tw e e n b uild ing and park ing are as S e e d e v e lopm e nt cod e se ction 6 .0 0 .0 9 0 M ust prov id e park ing stall d im e nsions S ite P lan m ust includ e se tb ack m e asure m e nts M ust prov id e d istance b e tw e e n b uild ing s P le ase re m ov e arial ph oto from b ack g round to m ak e plan m ore le g ib le M ust sh ow snow storag e location/are a calculations on S ite P lan M ust prov id e north ind icator Incorre ct S tre e t lab e l M ust sh ow parce l line s