HomeMy WebLinkAboutSTRUCTURAL CALCS - 23-00848 - Bear World - Jurassic Creek Gift Shop
2023
estoddard@civilize.design
350 N 2nd East
Rexburg, ID 83440
208-206-6653
11/29/2023
Structural Calculations Package
Jurassic Creek, Madison County, Idaho
Brent E Crowther
11/29/23
Cy Hepworth Structural Calculations Package
Jurassic Creek Project No. 02-23-006
Civilize, PLLC 1 | P a g e
Jurassic Creek
Madison County, Idaho
Structural Calculations Package
Location Map
Figure 1: Location Map for Jurassic Creek
Cy Hepworth Structural Calculations Package
Jurassic Creek Project No. 02-23-006
Civilize, PLLC 1 | P a g e
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Calcs Package-
Hepworth.docx
Exhibit A
General Information
Project Analysis Worksheet
Structural Calculations
Design Loading
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek CHECKED
Project No.:02-23-006 DATE: 11/29/2023
Project Location
Risk Category per ASCE 7 =II Frost Depth =36 inches
Importance Factor (Is) = Unobstructed Slippery Surface =N
Ground Snow Load (Pg) =psf Roof Pitch =1 /12
Exposure Factor (Ce) = Roof Angle =4.8 degrees
Thermal Factor (Ct) = Slope Factor (Cs) =1.00
Flat Roof Snow Load, (Pf) = psf Sloped Roof Snow Load (Ps) =31.5 psf
Design Wind Speed (ultimate)MPH
Wind Exposure Zone 1 -6.9 psf
Enclosure Classification Zone 1 (net)4.26 psf
Internal Pressure Coefficient Zone 2 -11.7 psf
Zone 2 (net)-0.5 psf
Importance Factor =
Soil Site Class = SS =0.369 g
Seismic Design Category =S1 =0.141 g
Light-frame (wood) walls R =SDS =0.370 g
sheathed with wood structural Ωo =SD1 =0.218 g
panels rated for shear resistance Cd =
Cs =Seismic Weight =kips
Roof:4
1.7
1
3.5
2.2
0
12.4 psf
35 psf
20 psf
Floor:
5
2.5
3.5
1
2.2
0.8
15 psf
40 psf
60 psf
Wall:
4
1.7
1.2
1.5
2.8
3.8
15 psf
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/[PAW-Design Loads.xlsx]Design Loading
insulation .................................................
drywall ......................................................
miscellaneous ..........................................
Dead Load =
miscellaneous ..........................................
wood studs ..............................................
Floor Live Load =
Deck Live Load =
siding .......................................................
plywood ...................................................
Dead Load =
Mapped Spectral Response Accelerations
Design Spectral Response Accelerations
1.00
Seismic Loads:
C
Lateral Seismic Force Resisting System
3
4
0.084
D
6.5
Gravity Loads:
wood joists ...............................................
insulation .................................................
drywall ......................................................
miscellaneous ..........................................
shingles ...................................................
Dead Load =
covering ...................................................
plywood ...................................................
plywood ...................................................
wood truss at 24" o.c. ..............................
drywall ......................................................
insulation .................................................
Roof Live Load =
Snow Load =
0.18
Roof Uplift
Snow Loads:
1.0
50
0.9
1.0
31.5
Wind Loads:
Enclosed
C
90
USGS web services were down for some period of time and as a result this tool wasn't operational, resulting in timeout error.
USGS web services are now operational so this tool should work as expected.
Latitude, Longitude: 43.73823542, -111.86573197
Date 11/22/2023, 11:48:01 AM
Design Code Reference Document ASCE7-16
Risk Category II
Site Class D - Default (See Section 11.4.3)
Type Value Description
SS 0.369 MCER ground motion. (for 0.2 second period)
S1 0.141 MCER ground motion. (for 1.0s period)
SMS 0.556 Site-modified spectral acceleration value
SM1 0.327 Site-modified spectral acceleration value
SDS 0.37 Numeric seismic design value at 0.2 second SA
SD1 0.218 Numeric seismic design value at 1.0 second SA
Type Value Description
SDC D Seismic design category
Fa 1.505 Site amplification factor at 0.2 second
Fv 2.317 Site amplification factor at 1.0 second
PGA 0.158 MCEG peak ground acceleration
FPGA 1.485 Site amplification factor at PGA
PGAM 0.234 Site modified peak ground acceleration
TL 6 Long-period transition period in seconds
SsRT 0.369 Probabilistic risk-targeted ground motion. (0.2 second)
SsUH 0.394 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration
SsD 1.5 Factored deterministic acceleration value. (0.2 second)
S1RT 0.141 Probabilistic risk-targeted ground motion. (1.0 second)
S1UH 0.149 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration.
S1D 0.6 Factored deterministic acceleration value. (1.0 second)
PGAd 0.5 Factored deterministic acceleration value. (Peak Ground Acceleration)
PGAUH 0.158 Uniform-hazard (2% probability of exceedance in 50 years) Peak Ground Acceleration
CRS 0.937 Mapped value of the risk coefficient at short periods
CR1 0.951 Mapped value of the risk coefficient at a period of 1 s
CV 0.946 Vertical coefficient
DISCLAIMER
While the information presented on this website is believed to be correct, SEAOC /OSHPD and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in this web application should not be used or
relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. SEAOC / OSHPD do not intend that the use of this information replace the
sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the seismic data provided by this
website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the
building site described by latitude/longitude location in the search results of this website.
Cy Hepworth Structural Calculations Package
Jurassic Creek Project No. 02-23-006
Civilize, PLLC 1 | P a g e
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Calcs Package-
Hepworth.docx
Exhibit B
Structural Calculations
Cy Hepworth Structural Calculations Package
Jurassic Creek Project No. 02-23-006
Civilize, PLLC | P a g e
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Calcs Package-
Hepworth.docx
JURASSIC CREEK
GIFT SHOP
JURASSIC CREEK GIFT SHOP KEY PLAN
SCALE: NTS
B.1 Seismic = 1347.5
Wind = 1525
B.2 Seismic = 1347.5
Wind = 1525
A.
1
Se
i
s
m
i
c
=
1
3
4
7
.
5
Wi
n
d
=
3
2
5
6
.
5
A.
2
Se
i
s
m
i
c
=
1
3
4
7
.
5
Wi
n
d
=
3
2
5
6
.
5
7/
1
6
U
N
B
L
O
C
K
E
D
6 I
N
E
D
G
E
12
I
N
F
I
E
L
D
7/16 UNBLOCKED
6 IN EDGE
12 IN FIELD
7/
1
6
U
N
B
L
O
C
K
E
D
6 I
N
E
D
G
E
12
I
N
F
I
E
L
D
7/16 UNBLOCKED
6 IN EDGE
12 IN FIELD
B1 B2 B3
B4
B5
B6
B7
B8 B9 B10 B11 B12
B13B14
B1
5
B16B17
B1
8
B1
9
B20
J1 J1
J3
J2
P1
4X
4
D
F
#
2
2X6 DF #2 @ 24" O.C.
(2) 2X6 DF #2 (2) 2X6 DF #2 (2) 2X6 DF #2
(2
)
1
.
7
5
X
9
.
2
5
2.
0
E
L
V
L
(2
)
1
.
7
5
X
5
.
5
2.
0
E
L
V
L
(2
)
1
.
7
5
X
5
.
5
2.
0
E
L
V
L
(2
)
1
.
7
5
X
7
.
2
5
2.
0
E
L
V
L
(2) 2X6 DF #2 (2) 2X6 DF #2 (2) 2X10 DF #2 (2) 2X6 DF #2 (2) 2X6 DF #2
3.125x7.5
24F-V4 GLB
3.125x7.5
24F-V4 GLB
3.125x7.5
24F-V4 GLB
3.125x7.5
24F-V4 GLB
3.
1
2
5
x
7
.
5
24
F
-
V
4
G
L
B
3.
1
2
5
x
7
.
5
24
F
-
V
4
G
L
B
3.
1
2
5
x
7
.
5
24
F
-
V
4
G
L
B
3.125x7.5
24F-V4 GLB
2X
6
D
F
#
2
@
2
4
"
O
.
C
.
2X6 DF #2 @ 24" O.C.
2X6 DF #2 @ 24" O.C.
2X6 DF #2 @ 24" O.C.
P2
4X
4
D
F
#
2
P3
4X
4
D
F
#
2
P4
4X
4
D
F
#
2
P5
4X
4
D
F
#
2
P6
4X
4
D
F
#
2
P7
4X4 DF
#
2
P8
4X4 DF
#
2
P
9
4
X
4
D
F
#
2
P
1
0
4
X
4
D
F
#
2
Cy Hepworth Structural Calculations Package
Jurassic Creek Project No. 02-23-006
Civilize, PLLC | P a g e
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Calcs Package-
Hepworth.docx
JURASSIC CREEK
RESTROOM
GRAVITY DESIGN
Project Analysis Worksheet
Structural Calculations
Continuous Footing
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Gift Shop CHECKED EAS
Project No.:02-23-006 DATE: 11/22/2023
Description:
Soil Bearing Pressure (q) =1500 psf
Allowable Soil Bearing (qu) =2154 psf qmin =142.00 psf
Soil Bearing Pressure (qmax)=1704 psf OK
Tributary Length (ft) P Dead (lbs/ft) P Live (lbs/ft) Pu (lbs/ft)
Roof Loading:30 450.00 1050.00 2220.00
Floor Loading:0 0.00 0.00 0.00
Wall Loading:14 280.00 0.00 336.00
Total Loads(lbs/ft) =730.00 1050.00 2556.00
Ultimate Ratio = 1.44
Footing Dimensions
Width = inches Width =8 inches
Thickness = inches Height 0 inches
Max Point Load on Stem Wall (Pmax) =4,125.0 lbs
Max Point Load at opening (Pmax) =2,493.3 lbs
Continuous Reinforcing area of bar(in^2) =0.20 Min p =0.0018
Rebar Size =#4 fy = psi bar diameter(in) =0.50 Max p =0.0134
f'c = psi Total Bars =2 Use p =0.0018
B1 =0.85 As req(in^2)=0.2592
8 inches
Stemwall Height =0 Footing Thickness =8 inches
(2)#4
18 inches
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Gift Shop Calcs/[PAW Cont Foot - JURASSIC Gift Shop.xlsx]Footing 1 (2)
Soil Conditions:
Footing and Stem Wall Dimensions:
Loading:
Dead Load (lbs) Live Load (lbs)
15 35
2500
0 0
20 0
Stemwall Dimensions
18
8
Footing Rebar:
60000
Footing Design
Stemwall Width =
inches
Continuous Rebar
Footing Width =
Concrete Pad Footing
Strength Design per ACI 318-11
Mark: SonoTube:
inches
Material Data
P Self (k) =0.77 M DL (k-ft) =0.00 Allowable q (psf) =1500
P DL (k) =0.43 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85
P LL (k) =1.11 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40
Pu (k) =3.2 Mu (k-ft) =0.00 Bars #4 and bigger, Fy (ksi) = 60
e (ft) = 0.00
within middle 3rd
Footing Dimensions: Column/Pier Base: Shear Check:
Long (ft) =1.33 Long Direction (in) =12 Punching Vc (psi) = 170
Short (ft) =1.33 Short Direction (in)=12 Wide Bm Vc (psi) = 85
Thickness (in) =36 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in)
% in center band B=100% 2784 >-389 OK
Punching Shear Resistance (k) > Applied Force (k)
Bearing Pressures:997 >-22 OK
q min (psf) =1308 q max (psf) =1308 OK
qu-max (psf) =1821 qu at edge of base (psf) =1821
qu-min (psf) =1821 qu at edge of base (psf) =1821
Reinforcing:
Reinforcement Top and Bottom(Y/N) =N
Base As(min) on calc'd As(4/3) (Y/N) =Y
Check Development Length
L' long (ft) = 0.16 Bar size =#4 p =0.0000 Fy (psi) = 60000
Mu (k-ft) = 0.02 area of bar = 0.20 Min p =0.0000 Ld1 (in) =24.0
d (in)= 32.75 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12
As req(in^2/ft)= 0.00 Spacing (in) = 10746 Use p =0.0000 Ld3 (in) =12
Total Bars = 1 Less than pmax, OK Available Ld (in) = 43.7 OK
Check Development Length
L' short (ft) = 0.16 Bar size =#4 p =0.0000 Fy (psi) = 60000
Mu (k-ft) = 0.01 area of bar = 0.20 Min p =0.0000 Ld1 (in) =24.0
d (in)= 32.25 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12
As req(in^2/ft)= 0.00 Spacing (in) = 21491 Use p =0.0000 Ld3 (in) =12
Total Bars = 1 Less than pmax, OK Available Ld (in) = 43.2 OK
P1 - Gift Shop Use:
w/ 1 #4
1.3 feet long x 1.3 feet wide x 36'' thick Footing
Each Way
Short Direction Check p
P1 - Gift Shop 18
Loads: (U = 1.2DL + 1.6LL)
Long Direction Check p
Project Jurassic Creek 0.00
Job No.Gift Shop 0.00
By 0.00 0.00
Date 11/29/23 0.00
Sheet _____ of ______
NBSD-Software.Com
DRIFTS ON ROOF PROJECTIONS AND PARAPETS
ASCE 7-10 CHAPTER 7 - SNOW LOADS
COMMERCIAL BUILDING - SAMPLE PROJECT, ANYTOWN
1. Snow Parameter Data
Building Parameters
L =328.75 feet (Length of Building)
W =75.33 feet (Width of Building)
Hp =4.50 feet (Height of parapet)
Snow Design Parameters Note: Tables and Figures provided courtesy of American Society of Civil Engineers (ASCE).
Occupancy:II (ASCE 7-10 Table 1.5-1)
Fully
Exposed
Partially
Exposed Sheltered
pg =40 B 0.9 1.0 1.2
C 0.9 1.0 1.1
EXP =B (Exposure Category, ASCE 7-10 Chapt 26.7)D 0.8 0.9 1.0
Above the treeline in widswept mountainous areas 0.7 0.8 N/A
Note:
House Structure
Kept at
Room Temp
Kept Above
Freezing Unheated
Greenhous
e with
Insulation
Thermal
Condition x
Note:
Fully
Exposed
Partially
Exposed Sheltered
Roof Condition x
2. Determination of Flat Roof Snow Load, Pf (Section 7.3)
Pf = 0.7 Cs Ct Is Pg (7.3-1)Where Ce =0.9 lb/ft2 (Exposure Factor, from Figure 7-2)
Ct =1.10 (Thermal Factor, Table 7-3)
I =1.00 (Importance factor, from ASCE 7-10 Table 1.5-2)
pg =40 lb/ft2 (Ground Snow Load, from Figure 7-1)
Pf =27.72 psf
3. Determination of Drift Loads (7.7)
a) Determination of Snow Density
γ = 0.13 Pg + 14 < 30 pcf (7.7-1)
Where pg =40 psf
γ = 19.20 pcf
b) Determination of Clear Height, hc
hc = Hp - hb Where Hp =4.50 feet (Height of parapet)
hb = pf / γ and pf =27.72 psf (Flat roof snow load)
γ = 19.20 pcf
hb = 1.44 feet (height of balanced snow load)
hc =3.06 feet
Chapter 26.7
N Above the treeline in widswept mountainous areas
(Y or N) ?
In Alaska, in areas where trees do not exist within a 2-
mile radius of the site
Table 7-2 Exposure Factor, Ce
Terrain Category
lb/ft2 (Ground Snow Load, from
Figure 7-1)
Chapter 26.7
Chapter 26.7
Slippery Non-Slippery
0.7 0.8 N/A
N In Alaska, in areas where trees do not exist within a
2-mile radius of the site (Y or N) ?
Roof Surface
x
Metal, Slate, glass,
bituminous, rubber,
plastic surfaces with a
smooth surface.
Membranes with
imbedded aggregate or
mineral granule surface,
asphalt shingles, wood
shingles, shakes.
p s f 2 0 Pf o r 2 0 g
Hp
Page 1 of 2Snow Loads - Parapets - ASCE 7-10 Gravity Loads - JURASSIC Gift Shop 11/29/2023
Project Jurassic Creek 0.00
Job No.Gift Shop 0.00
By 0.00 0.00
Date 11/29/23 0.00
Sheet _____ of ______
NBSD-Software.Com
DRIFTS ON ROOF PROJECTIONS AND PARAPETS
ASCE 7-10 CHAPTER 7 - SNOW LOADS
COMMERCIAL BUILDING - SAMPLE PROJECT, ANYTOWN
1. Snow Parameter Data
Building Parameters
L =328.75 feet (Length of Building)
W =75.33 feet (Width of Building)
Hp =4.50 feet (Height of parapet)
Hp
d) Determine if Drift Loads are Required (7.7.1)
Note:If hc/hb < 0.2, drift loads are not required to be applied, where hc =3.06 feet
hb =1.44 feet
hc/hb =2.12
Drift loads must be considered!
a) Drift along Length of Building
4. Drift Loads on Roof Projections (Sect 7.7)
Pd = 86.40 psf Pf = 27.7 psf
a) Drift along Length of Building
4.50'
Lu = L =329 ft (Length of building)
pg =40 lb/ft2 (Ground Snow Load, from Figure 7-1)
0.75 hd =4.79 feet
w = 24.45'
Drift Width
Where hd =4.79 feet
hc =3.06 feet
<= Governs!
Thus, w =24.45 feet
hd =3.06 feet
Maximum Intensity of Drift Surcharge Load b) Drift along Width of Building
Pd = hd γ Where hd =4.50 feet Pd = 47.94 psf Pf = 27.7 psf
γ = 19.20 pcf
Pd =86.4 psf 2.50'
b) Drift along Width of Building
Lu = L =75 ft (Length of building)w = 9.99'
pg =40 lb/ft2 (Ground Snow Load, from Figure 7-1)
0.75 hd =2.50 feet
Drift Width
<= Governs! Where hd =2.50 feet
hc =3.06 feet
Thus, w =9.99 feet
hd =2.50 feet
Maximum Intensity of Drift Surcharge Load
Pd = hd γ Where hd =2.50 feet
γ = 19.20 pcf
Pd =47.9 psf
(7.7.1) 1.5 - 10 p L 0.43 0.75 h 0.75 4 g3ud
dddcdh 4 wand h h ,h h If
h 8 h
h 4 wand h h ,h h If c
c
2
d
cdcd
(7.7.1) 1.5 - 10 p L 0.43 0.75 h 0.75 4 g3ud
dddcdh 4 wand h h ,h h If
h 8 h
h 4 wand h h ,h h If c
c
2
d
cdcd
Page 2 of 2Snow Loads - Parapets - ASCE 7-10 Gravity Loads - JURASSIC Gift Shop 11/29/2023
Wall Height: 10'Member Height: 9' 7 1/2"O. C. Spacing: 16.00"
Design Results Actual Allowed Result LDF Load: Combination
Slenderness 21 50 Passed (42%)----
Compression (lbs)1880 7329 Passed (26%)1.15 1.0 D + 1.0 S
Plate Bearing (lbs)1880 6445 Passed (29%)--1.0 D + 1.0 S
Lateral Reaction (lbs)93 ----1.60 1.0 D + 0.6 W
Lateral Shear (lbs)84 1584 Passed (5%)1.60 1.0 D + 0.6 W
Lateral Moment (ft-lbs)223 @ mid-span 1342 Passed (17%)1.60 1.0 D + 0.6 W
Total Deflection (in)0.08 @ mid-span 0.48 Passed (L/1477)--1.0 D + 0.6 W
Bending/Compression 0.19 1 Passed (19%)1.60 1.0 D + 0.45 W + 0.75 L + 0.75 S
•Lateral deflection criteria: Wind (L/240)
•Input axial load eccentricity for the design is zero
•Applicable calculations are based on NDS.
•A bearing area factor of 1.25 has been applied to base plate bearing capacity.
•A 15% increase in the moment capacity has been added to account for repetitive member usage.
Supports Type Material
Top Dbl 2X Douglas Fir-Larch
Base 2X Douglas Fir-Larch
Max Unbraced Length Comments
1'
System : Wall
Member Type : Stud
Building Code : IBC 2018
Design Methodology : ASD
Lateral Connections
Supports Connector Type/Model Quantity Connector Nailing
Top Nails 8d (0.113" x 2 1/2") (Toe)2 N/A
Base Nails 8d (0.113" x 2 1/2") (Toe)2 N/A
•Nailed connection at the top of the member is assumed to be nailed through the bottom 2x plate prior to placement of the top 2x of the double top plate assembly.
Dead Snow
Vertical Load Spacing (0.90)(1.15)Comments
1 - Point (PLF)16.00"360.0 1050.0 Default Load
• ASCE/SEI 7 Sec. 30.4: Exposure Category (B), Mean Roof Height (19'), Topographic Factor (1.0), Wind Directionality Factor (0.85), Basic Wind Speed (115), Risk Category(II), Effective Wind Area
determined using full member span and trib. width.
• IBC Table 1604.3, footnote f: Deflection checks are performed using 42% of this lateral wind load.
Wind
Lateral Load Location Spacing (1.60)Comments
1 - Uniform (PSF)Full Length 16.00"24.1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
Drawing is Conceptual
MEMBER REPORT PASSED
Level, CENTER WALL
1 piece(s) 2 x 6 DF No.2 @ 16" OC
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ericalanstoddard@gmail.com
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)493 @ 10' 5 1/4"3828 (3.50")Passed (13%)--1.0 D + 1.0 L (All Spans)
Shear (lbs)247 @ 9' 10"1829 Passed (14%)1.00 1.0 D + 1.0 L (All Spans)
Moment (Ft-lbs)-567 @ 10' 5 1/4"2126 Passed (27%)1.00 1.0 D + 1.0 L (All Spans)
Live Load Defl. (in)0.459 @ 15' 7"0.343 Failed (2L/268)--1.0 D + 1.0 L (Alt Spans)
Total Load Defl. (in)0.469 @ 15' 7"0.515 Passed (2L/264)--1.0 D + 1.0 L (Alt Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Overhang deflection criteria: LL (2L/360) and TL (2L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ¹ See Connector grid below for additional information and/or requirements.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Floor Live Wind Factored Accessories
1 - Hanger on 5 1/2" DF beam 3.50"Hanger¹1.50"11 215/-41 97/-18 225/-30 See note ¹
2 - Stud wall - DF 3.50"3.50"1.50"32 461 207 493 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)15' 4" o/c
Bottom Edge (Lu)15' 4" o/c
Connector: Simpson Strong-Tie
Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories
1 - Face Mount Hanger HU1.81/5 2.50"N/A 12-10dx1.5 4-10dx1.5
•Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead Floor Live Wind
Vertical Loads Location (Side)Tributary Width (0.90)(1.00)(1.60)Comments
0 - Self Weight (PLF)3 1/2" to 15' 7"N/A 2.8 ----
1 - Uniform (PSF)0 to 15' 7" (Front)1'-40.0 18.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT
Level, Floor: Drop Beam
1 piece(s) 1 3/4" x 5 1/2" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)534 @ 0 2813 (1.50")Passed (19%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)387 @ 7"2277 Passed (17%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)567 @ 2' 1 1/2"1696 Passed (33%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.022 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.028 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"111 423 534 None
2 - Trimmer - DF 1.50"1.50"1.50"111 423 534 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 3" o/c
Bottom Edge (Lu)4' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 4' 3"N/A 4.2 --
1 - Uniform (PSF)0 to 4' 3"4'12.0 35.0 Default Load
2 - Uniform (PLF)0 to 4' 3"N/A -59.0 Drift Load (4'
*14.77 psf)
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B1
2 piece(s) 2 x 6 DF No.2
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ericalanstoddard@gmail.com
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)785 @ 0 2813 (1.50")Passed (28%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)638 @ 7"2277 Passed (28%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1226 @ 3' 1 1/2"1696 Passed (72%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.103 @ 3' 1 1/2"0.208 Passed (L/731)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.130 @ 3' 1 1/2"0.313 Passed (L/579)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"163 622 785 None
2 - Trimmer - DF 1.50"1.50"1.50"163 622 785 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 3" o/c
Bottom Edge (Lu)6' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 3"N/A 4.2 --
1 - Uniform (PSF)0 to 6' 3"4'12.0 35.0 Default Load
2 - Uniform (PLF)0 to 6' 3"N/A -59.0 Drift Load (4'
*14.77 psf)
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B2
2 piece(s) 2 x 6 DF No.2
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ericalanstoddard@gmail.com
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)534 @ 0 2813 (1.50")Passed (19%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)387 @ 7"2277 Passed (17%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)567 @ 2' 1 1/2"1696 Passed (33%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.022 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.028 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"111 423 534 None
2 - Trimmer - DF 1.50"1.50"1.50"111 423 534 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 3" o/c
Bottom Edge (Lu)4' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 4' 3"N/A 4.2 --
1 - Uniform (PSF)0 to 4' 3"4'12.0 35.0 Default Load
2 - Uniform (PLF)0 to 4' 3"N/A -59.0 Drift Load (4'
*14.77 psf)
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B3
2 piece(s) 2 x 6 DF No.2
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ericalanstoddard@gmail.com
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2300 @ 0 3938 (1.50")Passed (58%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1475 @ 7"4206 Passed (35%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1869 @ 1' 7 1/2"4889 Passed (38%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.035 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.048 @ 1' 7 1/2"0.162 Passed (L/816)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"594 1706 2300 None
2 - Trimmer - DF 1.50"1.50"1.50"594 1706 2300 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3' 3" o/c
Bottom Edge (Lu)3' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 3' 3"N/A 5.6 --
1 - Uniform (PSF)0 to 3' 3"30'12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B4
2 piece(s) 1 3/4" x 5 1/2" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ericalanstoddard@gmail.com
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)3726 @ 0 3938 (1.50")Passed (95%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)2454 @ 10 3/4"7074 Passed (35%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)4890 @ 2' 7 1/2"12884 Passed (38%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.052 @ 2' 7 1/2"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.070 @ 2' 7 1/2"0.262 Passed (L/901)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"970 2756 3726 None
2 - Trimmer - DF 1.50"1.50"1.50"970 2756 3726 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 3" o/c
Bottom Edge (Lu)5' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 5' 3"N/A 9.4 --
1 - Uniform (PSF)0 to 5' 3"30'12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B5
2 piece(s) 1 3/4" x 9 1/4" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ericalanstoddard@gmail.com
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2300 @ 0 3938 (1.50")Passed (58%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1475 @ 7"4206 Passed (35%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1869 @ 1' 7 1/2"4889 Passed (38%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.035 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.048 @ 1' 7 1/2"0.162 Passed (L/816)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"594 1706 2300 None
2 - Trimmer - DF 1.50"1.50"1.50"594 1706 2300 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3' 3" o/c
Bottom Edge (Lu)3' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 3' 3"N/A 5.6 --
1 - Uniform (PSF)0 to 3' 3"30'12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B6
2 piece(s) 1 3/4" x 5 1/2" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ericalanstoddard@gmail.com
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1786 @ 0 3938 (1.50")Passed (45%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1369 @ 8 3/4"5544 Passed (25%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)2790 @ 3' 1 1/2"8182 Passed (34%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.074 @ 3' 1 1/2"0.208 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.101 @ 3' 1 1/2"0.313 Passed (L/743)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"473 1313 1786 None
2 - Trimmer - DF 1.50"1.50"1.50"473 1313 1786 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 3" o/c
Bottom Edge (Lu)6' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 3"N/A 7.4 --
1 - Uniform (PSF)0 to 6' 3"12'12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B7
2 piece(s) 1 3/4" x 7 1/4" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ericalanstoddard@gmail.com
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)838 @ 0 2813 (1.50")Passed (30%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)608 @ 7"2277 Passed (27%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)890 @ 2' 1 1/2"1696 Passed (52%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.034 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.043 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"192 646 838 None
2 - Trimmer - DF 1.50"1.50"1.50"192 646 838 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 3" o/c
Bottom Edge (Lu)4' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 4' 3"N/A 4.2 --
1 - Uniform (PSF)0 to 4' 3"4'12.0 35.0 Default Load
2 - Uniform (PLF)0 to 4' 3"N/A -59.0 Drift Load (4'
*14.77 psf)
3 - Uniform (PSF)0 to 4' 3"3'12.6 35.0 Porch
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B8
2 piece(s) 2 x 6 DF No.2
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)838 @ 0 2813 (1.50")Passed (30%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)608 @ 7"2277 Passed (27%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)890 @ 2' 1 1/2"1696 Passed (52%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.034 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.043 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"192 646 838 None
2 - Trimmer - DF 1.50"1.50"1.50"192 646 838 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 3" o/c
Bottom Edge (Lu)4' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 4' 3"N/A 4.2 --
1 - Uniform (PSF)0 to 4' 3"4'12.0 35.0 Default Load
2 - Uniform (PLF)0 to 4' 3"N/A -59.0 Drift Load (4'
*14.77 psf)
3 - Uniform (PSF)0 to 4' 3"3'12.6 35.0 Porch
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B9
2 piece(s) 2 x 6 DF No.2
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1241 @ 0 2813 (1.50")Passed (44%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)885 @ 10 3/4"3830 Passed (23%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1938 @ 3' 1 1/2"4059 Passed (48%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.033 @ 3' 1 1/2"0.208 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.043 @ 3' 1 1/2"0.313 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"291 950 1241 None
2 - Trimmer - DF 1.50"1.50"1.50"291 950 1241 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 3" o/c
Bottom Edge (Lu)6' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 3"N/A 7.0 --
1 - Uniform (PSF)0 to 6' 3"4'12.0 35.0 Default Load
2 - Uniform (PLF)0 to 6' 3"N/A -59.0 Drift Load (4'
*14.77 psf)
3 - Uniform (PSF)0 to 6' 3"3'12.6 35.0 Porch
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B10
2 piece(s) 2 x 10 DF No.2
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)838 @ 0 2813 (1.50")Passed (30%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)608 @ 7"2277 Passed (27%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)890 @ 2' 1 1/2"1696 Passed (52%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.034 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.043 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"192 646 838 None
2 - Trimmer - DF 1.50"1.50"1.50"192 646 838 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 3" o/c
Bottom Edge (Lu)4' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 4' 3"N/A 4.2 --
1 - Uniform (PSF)0 to 4' 3"4'12.0 35.0 Default Load
2 - Uniform (PLF)0 to 4' 3"N/A -59.0 Drift Load (4'
*14.77 psf)
3 - Uniform (PSF)0 to 4' 3"3'12.6 35.0 Porch
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B11
2 piece(s) 2 x 6 DF No.2
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)838 @ 0 2813 (1.50")Passed (30%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)608 @ 7"2277 Passed (27%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)890 @ 2' 1 1/2"1696 Passed (52%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.034 @ 2' 1 1/2"0.142 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.043 @ 2' 1 1/2"0.213 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"192 646 838 None
2 - Trimmer - DF 1.50"1.50"1.50"192 646 838 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)4' 3" o/c
Bottom Edge (Lu)4' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 4' 3"N/A 4.2 --
1 - Uniform (PSF)0 to 4' 3"4'12.0 35.0 Default Load
2 - Uniform (PLF)0 to 4' 3"N/A -59.0 Drift Load (4'
*14.77 psf)
3 - Uniform (PSF)0 to 4' 3"3'12.6 35.0 Porch
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B12
2 piece(s) 2 x 6 DF No.2
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)816 @ 2"6836 (3.50")Passed (12%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)660 @ 11"4762 Passed (14%)1.15 1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)1820 @ 4' 9 1/2"6738 Passed (27%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.102 @ 4' 9 1/2"0.308 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.142 @ 4' 9 1/2"0.463 Passed (L/783)--1.0 D + 1.0 S (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 9' 3".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Stud wall - DF 3.50"3.50"1.50"229 587 816 Blocking
2 - Stud wall - DF 3.50"3.50"1.50"229 587 816 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)9' 7" o/c
Bottom Edge (Lu)9' 7" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 9' 7"N/A 5.7 --
1 - Uniform (PSF)0 to 9' 7" (Front)3' 6"12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B13
1 piece(s) 3 1/8" x 7 1/2" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)816 @ 2"6836 (3.50")Passed (12%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)660 @ 11"4762 Passed (14%)1.15 1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)1820 @ 4' 9 1/2"6738 Passed (27%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.102 @ 4' 9 1/2"0.308 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.142 @ 4' 9 1/2"0.463 Passed (L/783)--1.0 D + 1.0 S (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 9' 3".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Stud wall - DF 3.50"3.50"1.50"229 587 816 Blocking
2 - Stud wall - DF 3.50"3.50"1.50"229 587 816 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)9' 7" o/c
Bottom Edge (Lu)9' 7" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 9' 7"N/A 5.7 --
1 - Uniform (PSF)0 to 9' 7" (Front)3' 6"12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B14
1 piece(s) 3 1/8" x 7 1/2" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)875 @ 2"6836 (3.50")Passed (13%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)611 @ 11"4762 Passed (13%)1.15 1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)1189 @ 3' 1/2"6738 Passed (18%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.026 @ 3' 1/2"0.192 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.036 @ 3' 1/2"0.287 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 5' 9".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Stud wall - DF 3.50"3.50"1.50"236 639 875 Blocking
2 - Stud wall - DF 3.50"3.50"1.50"236 639 875 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 1" o/c
Bottom Edge (Lu)6' 1" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 1"N/A 5.7 --
1 - Uniform (PSF)0 to 6' 1" (Front)6'12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B15
1 piece(s) 3 1/8" x 7 1/2" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)816 @ 2"6836 (3.50")Passed (12%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)660 @ 11"4762 Passed (14%)1.15 1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)1820 @ 4' 9 1/2"6738 Passed (27%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.102 @ 4' 9 1/2"0.308 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.142 @ 4' 9 1/2"0.463 Passed (L/783)--1.0 D + 1.0 S (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 9' 3".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Stud wall - DF 3.50"3.50"1.50"229 587 816 Blocking
2 - Stud wall - DF 3.50"3.50"1.50"229 587 816 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)9' 7" o/c
Bottom Edge (Lu)9' 7" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 9' 7"N/A 5.7 --
1 - Uniform (PSF)0 to 9' 7" (Front)3' 6"12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B16
1 piece(s) 3 1/8" x 7 1/2" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)816 @ 2"6836 (3.50")Passed (12%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)660 @ 11"4762 Passed (14%)1.15 1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)1820 @ 4' 9 1/2"6738 Passed (27%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.102 @ 4' 9 1/2"0.308 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.142 @ 4' 9 1/2"0.463 Passed (L/783)--1.0 D + 1.0 S (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 9' 3".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Stud wall - DF 3.50"3.50"1.50"229 587 816 Blocking
2 - Stud wall - DF 3.50"3.50"1.50"229 587 816 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)9' 7" o/c
Bottom Edge (Lu)9' 7" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 9' 7"N/A 5.7 --
1 - Uniform (PSF)0 to 9' 7" (Front)3' 6"12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B17
1 piece(s) 3 1/8" x 7 1/2" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)875 @ 2"6836 (3.50")Passed (13%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)611 @ 11"4762 Passed (13%)1.15 1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)1189 @ 3' 1/2"6738 Passed (18%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.026 @ 3' 1/2"0.192 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.036 @ 3' 1/2"0.287 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 5' 9".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Stud wall - DF 3.50"3.50"1.50"236 639 875 Blocking
2 - Stud wall - DF 3.50"3.50"1.50"236 639 875 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 1" o/c
Bottom Edge (Lu)6' 1" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 6' 1"N/A 5.7 --
1 - Uniform (PSF)0 to 6' 1" (Front)6'12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B18
1 piece(s) 3 1/8" x 7 1/2" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)901 @ 2"6836 (3.50")Passed (13%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)745 @ 11"4762 Passed (16%)1.15 1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)2235 @ 5' 3 1/2"6738 Passed (33%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.154 @ 5' 3 1/2"0.342 Passed (L/799)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.214 @ 5' 3 1/2"0.512 Passed (L/575)--1.0 D + 1.0 S (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 10' 3".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Stud wall - DF 3.50"3.50"1.50"252 648 901 Blocking
2 - Stud wall - DF 3.50"3.50"1.50"252 648 901 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)10' 7" o/c
Bottom Edge (Lu)10' 7" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 10' 7"N/A 5.7 --
1 - Uniform (PSF)0 to 10' 7" (Front)3' 6"12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B19
1 piece(s) 3 1/8" x 7 1/2" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)901 @ 2"6836 (3.50")Passed (13%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)745 @ 11"4762 Passed (16%)1.15 1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)2235 @ 5' 3 1/2"6738 Passed (33%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.154 @ 5' 3 1/2"0.342 Passed (L/799)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.214 @ 5' 3 1/2"0.512 Passed (L/575)--1.0 D + 1.0 S (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 10' 3".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Stud wall - DF 3.50"3.50"1.50"252 648 901 Blocking
2 - Stud wall - DF 3.50"3.50"1.50"252 648 901 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)10' 7" o/c
Bottom Edge (Lu)10' 7" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 10' 7"N/A 5.7 --
1 - Uniform (PSF)0 to 10' 7" (Front)3' 6"12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B20
1 piece(s) 3 1/8" x 7 1/2" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)335 @ 2 1/2"3281 (3.50")Passed (10%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)261 @ 8 11/16"1139 Passed (23%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)483 @ 3' 3 1/2"975 Passed (50%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.076 @ 3' 3 1/2"0.325 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.110 @ 3' 3 1/2"0.433 Passed (L/706)--1.0 D + 1.0 S (All Spans)
System : Roof
Member Type : Joist
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 4/12
•Deflection criteria: LL (L/240) and TL (L/180).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•A 15% increase in the moment capacity has been added to account for repetitive member usage.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Beveled Plate - DF 3.50"3.50"1.50"104 230 335 Blocking
2 - Beveled Plate - DF 3.50"3.50"1.50"104 230 335 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)6' 11" o/c
Bottom Edge (Lu)6' 11" o/c
Dead Snow
Vertical Load Location (Side)Spacing (0.90)(1.15)Comments
1 - Uniform (PSF)0 to 6' 7"24"15.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.Member Length : 7' 1 1/8"
MEMBER REPORT PASSED
Level, J1
1 piece(s) 2 x 6 DF No.2 @ 24" OC
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)258 @ 2 1/2"3281 (3.50")Passed (8%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)184 @ 8 11/16"1139 Passed (16%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)277 @ 2' 6 1/2"975 Passed (28%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.025 @ 2' 6 1/2"0.246 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.036 @ 2' 6 1/2"0.328 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Roof
Member Type : Joist
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 4/12
•Deflection criteria: LL (L/240) and TL (L/180).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•A 15% increase in the moment capacity has been added to account for repetitive member usage.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Beveled Plate - DF 3.50"3.50"1.50"80 178 258 Blocking
2 - Beveled Plate - DF 3.50"3.50"1.50"80 178 258 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 4" o/c
Bottom Edge (Lu)5' 4" o/c
Dead Snow
Vertical Load Location (Side)Spacing (0.90)(1.15)Comments
1 - Uniform (PSF)0 to 5' 1"24"15.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.Member Length : 5' 6 1/8"
MEMBER REPORT PASSED
Level, J2
1 piece(s) 2 x 6 DF No.2 @ 24" OC
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)258 @ 2 1/2"3281 (3.50")Passed (8%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)184 @ 8 11/16"1139 Passed (16%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)277 @ 2' 6 1/2"975 Passed (28%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.025 @ 2' 6 1/2"0.246 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.036 @ 2' 6 1/2"0.328 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Roof
Member Type : Joist
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 4/12
•Deflection criteria: LL (L/240) and TL (L/180).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•A 15% increase in the moment capacity has been added to account for repetitive member usage.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Beveled Plate - DF 3.50"3.50"1.50"80 178 258 Blocking
2 - Beveled Plate - DF 3.50"3.50"1.50"80 178 258 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 4" o/c
Bottom Edge (Lu)5' 4" o/c
Dead Snow
Vertical Load Location (Side)Spacing (0.90)(1.15)Comments
1 - Uniform (PSF)0 to 5' 1"24"15.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.Member Length : 5' 6 1/8"
MEMBER REPORT PASSED
Level, J3
1 piece(s) 2 x 6 DF No.2 @ 24" OC
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Post Height: 9'
Design Results Actual Allowed Result LDF Load: Combination
Slenderness 31 50 Passed (62%)----
Compression (lbs)1691 5727 Passed (30%)1.15 1.0 D + 1.0 S
Base Bearing (lbs)1691 363825 Passed (0%)--1.0 D + 1.0 S
Bending/Compression 0.22 1 Passed (22%)1.15 1.0 D + 1.0 S
•Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
•Applicable calculations are based on NDS.
Supports Type Material
Base Beam Steel
Max Unbraced Length Comments
Full Member Length No bracing assumed.
Member Type : Free Standing Post
Building Code : IBC 2018
Design Methodology : ASD
Dead Snow
Vertical Loads (0.90)(1.15)Comments
1 - Point (lb)229 587 Linked from: B14, Support 1
2 - Point (lb)236 639 Linked from: B15, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
Drawing is Conceptual
MEMBER REPORT PASSED
Level, P4
1 piece(s) 4 x 4 DF No.2
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Post Height: 9'
Design Results Actual Allowed Result LDF Load: Combination
Slenderness 31 50 Passed (62%)----
Compression (lbs)900 5727 Passed (16%)1.15 1.0 D + 1.0 S
Base Bearing (lbs)900 363825 Passed (0%)--1.0 D + 1.0 S
Bending/Compression 0.08 1 Passed (8%)1.15 1.0 D + 1.0 S
•Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
•Applicable calculations are based on NDS.
Supports Type Material
Base Beam Steel
Max Unbraced Length Comments
Full Member Length No bracing assumed.
Member Type : Free Standing Post
Building Code : IBC 2018
Design Methodology : ASD
Dead Snow
Vertical Load (0.90)(1.15)Comments
1 - Point (lb)252 648 Linked from: B19, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
Drawing is Conceptual
MEMBER REPORT PASSED
Level, P7
1 piece(s) 4 x 4 DF No.2
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Post Height: 9'
Design Results Actual Allowed Result LDF Load: Combination
Slenderness 31 50 Passed (62%)----
Compression (lbs)900 5727 Passed (16%)1.15 1.0 D + 1.0 S
Base Bearing (lbs)900 363825 Passed (0%)--1.0 D + 1.0 S
Bending/Compression 0.08 1 Passed (8%)1.15 1.0 D + 1.0 S
•Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
•Applicable calculations are based on NDS.
Supports Type Material
Base Beam Steel
Max Unbraced Length Comments
Full Member Length No bracing assumed.
Member Type : Free Standing Post
Building Code : IBC 2018
Design Methodology : ASD
Dead Snow
Vertical Load (0.90)(1.15)Comments
1 - Point (lb)252 648 Linked from: B19, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
Drawing is Conceptual
MEMBER REPORT PASSED
Level, P8
1 piece(s) 4 x 4 DF No.2
ForteWEB Software Operator Job Notes 11/29/2023 11:34:32 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Gift Shop
Location:
Height (ft) =10.0 Gravity Loads to Wall:
Le/d = 21.8 < 50 OK DL(psf) trib(ft) w e(in)
deflection < L/240 roof snow 12 15 705 0
wind/seismic (W/S)W floor live load 0 0 0 0
wind load, w (psf) =30 (Due to Wind)wall weight 15 15 225
0.6 * w = (psf) 18.0 misc. live load 0 0 0 0
snow load? (Y/N)Y w (total uniform load) = 930 plf
Lumber Grade: (DF No. 2)
Load Cases:
CD =1.60 CD =1.60 CD =1.15
P (lbs) = 540 per stud P (lbs) = 525 P (lbs) = 1240 per stud
M (lb-ft) = 300 M (lb-ft) = 225 M (lb-ft) = 0
FcE (psi) =1002 FcE (psi) =1002 FcE (psi) =1002
Fc' (psi) = 894 Fc' (psi) = 894 Fc' (psi) = 839
fc (psi) = 65 < Fc'OK fc (psi) = 64 < Fc'OK fc (psi) = 150 < Fc'OK
Fb' (psi) = 2153 Fb' (psi) = 2153 Fb' (psi) = 1547
fb (psi) = 476 < Fb'OK fb (psi) = 357 < Fb'OK fb (psi) = 0 < Fb'OK
CSR = 0.24 < 1.0 OK CSR = 0.18 < 1.0 OK CSR = 0.03 < 1.0 OK
D (in.) =0.11 = L/1056 OK D (in.) =0.09 = L/1408 OK D (in.) =0.00 = L/5000 OK
USE:2 x 6
Framing at Openings:
Trimmers: King Studs:
Trimmer supports only vertical load ... King stud supports only bending ...
Pcap (lbs) = 6924 Mcap (lb-ft) = 1180
Rcap (lbs) = 5156
(bearing governs)trib width capacity (ft) = 5.24 for M < Mcap
(governs)
trib width capacity (ft) = 5.87 for D < L /240
(DF No. 2)Typical 10'-0" Plate
1
319'-7'' to 30'-1''
1
1
1
1
29'-1'' to 19'-7''
< 9'-1''
30'-1'' to 40'-7'' 4
3
1
1
4
2
1
11
1
Wood Stud Wall Design
Design based on NDS 2012
Trimmer Studs (TS) King Studs (KS)
at 16'' o.c.
D + S
Open Width (ft)
Typical 10'-0" Plate
0
LL(psf)
D + 0.6*W D + 0.75*(0.6*W + S + LL)
35
0
Location:
Height (ft) =10.0 Gravity Loads to Wall:
Le/d = 21.8 < 50 OK DL(psf) trib(ft) w e(in)
deflection < L/240 roof snow 12 15 705 0
wind/seismic (W/S)W floor live load 0 0 0 0
wind load, w (psf) =30 (Due to Wind)wall weight 15 15 225
0.6 * w = (psf) 18.0 misc. live load 0 0 0 0
snow load? (Y/N)Y w (total uniform load) = 930 plf
Lumber Grade: (2.0E - LVL)
Load Cases:
CD =1.60 CD =1.60 CD =1.15
P (lbs) = 405 per stud P (lbs) = 394 P (lbs) = 930 per stud
M (lb-ft) = 225 M (lb-ft) = 169 M (lb-ft) = 0
FcE (psi) =1755 FcE (psi) =1755 FcE (psi) =1755
Fc' (psi) = 1627 Fc' (psi) = 1627 Fc' (psi) = 1542
fc (psi) = 42 < Fc'OK fc (psi) = 41 < Fc'OK fc (psi) = 97 < Fc'OK
Fb' (psi) = 4811 Fb' (psi) = 4811 Fb' (psi) = 3458
fb (psi) = 306 < Fb'OK fb (psi) = 230 < Fb'OK fb (psi) = 0 < Fb'OK
CSR = 0.07 < 1.0 OK CSR = 0.05 < 1.0 OK CSR = 0.00 < 1.0 OK
D (in.) =0.06 = L/2054 OK D (in.) =0.04 = L/2738 OK D (in.) =0.00 = L/5000 OK
USE:1.75 x 5.5
Framing at Openings:
Trimmers: King Studs:
Trimmer supports only vertical load ... King stud supports only bending ...
Pcap (lbs) = 14842 Mcap (lb-ft) = 3401
Rcap (lbs) = 6016
(bearing governs)trib width capacity (ft) = #### for M < Mcap
trib width capacity (ft) = 8.56 for D < L /240 (governs)
35
Wood Stud Wall Design
Design based on NDS 2012
Typical 10'-0" Plate
LL(psf)
0
0
D + 0.6*W D + 0.75*(0.6*W + S + LL) D + S
Typical 10'-0" Plate at 12'' o.c.(2.0E - LVL)
Open Width (ft) Trimmer Studs (TS) King Studs (KS)
< 16'-1'' 2 1
16'-1'' to 33'-2'' 3 2
33'-2'' to 50'-4'' 4 3
50'-4'' to 67'-5'' 6 4
1 1 1
10 1 1
1 1 1
Cy Hepworth Structural Calculations Package
Jurassic Creek Project No. 02-23-006
Civilize, PLLC | P a g e
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Calcs Package-
Hepworth.docx
JURASSIC CREEK
GIFT SHOP
LATERAL DESIGN
Project JURASSIC CREEK
Job No.Gift Shop
By EAS
Date 11/29/23
Sheet _____ of ______
NBSD-Software.Com
MAIN WIND FORCE RESISTING SYSTEMS - WALLS AND ROOF
ASCE 7-10 WIND PROVISIONS - CHAPTER 28 - ENVELOPE PROCEDURE PART 2 - ENCLOSED SIMPLE DIAPHRAGM LOW-RISE BUILDINGS
ENCLOSED COMMERCIAL BUILDING - SAMPLE PROJECT, ANYTOWN
Requirements :- Building has Simple Diaphragms per Section 26.2
ASCE 7-10 Figure 28.6-1
1. Building Parameters Please note:
Risk Category:II (ASCE 7-10 Table 1.5-1) ASCE 7-10 Figure 28.6-1 data and information provided for reference courtesy of
Site Data American Society of Civil Engineers (ASCE) and Structural Engineering Institute (SEI).
EXP =C (Exposure Category per ASCE 26.7.3)
V =90 mph (Basic Wind Speed, ASCE 7-10 Fig 26.5-1A)
Building Dimensions
Vertical:Horizontal:
H1 = 15.00 feet m = 15.00 feet Roof Angle θ = 0.00 degrees (Windward Side)
H2 = 0.00 feet n = 15.00 feet = 7.59 degrees (Leeward Side)
H3 = 13.00 feet
H4 = 2.00 feet Mean Roof Height (ASCE 7-10 Section 26.2):
W = 30.00 feet (Transverse building dimension)
Hmr = AVERAGE (He,Hmax), for θ >10 degrees, otherwise He
L = 60.00 feet (Longitudinal building dimension)
Where Hmax =15.00 ft (maximum elevation)
Heave =15.00 ft (Max Eave Height)
Hmr =15.00 ft (Mean Roof Height)
2. Wind Velocity Pressure (ASCE 7-10 28.6.3)
ps = λ Kzt Ps30 (EQ 28.6-1)
Where λ =1.21 (Adjustment Factor for Building Height and Exposure, per Fig 6-2, Exp C, H = 15 feet)
Kzt =1.00 (Topographic Factor per Figure 6-4 - No info provided on topography)
ps =1.21 * ps30 psf (Wind Velocity Pressure)
3. Wind Pressure Values from ASCE 7-10 Figure 28.6-1, at Basic Wind Speed
a) Wind Pressures ps30 on MWFRS
For θ =7.59 degrees (Windward Side)
A B C D E F G H EOH GOH
90 0 to 5°1 19.2 -10.0 12.7 -5.9 -23.1 -13.1 -16.0 -10.1 -32.3 -25.3
10 1 21.6 -9.0 14.4 -5.2 -23.1 -14.1 -16.0 -10.8 -32.3 -25.3
15 1 24.1 -8.0 16.0 -4.6 -23.1 -15.1 -16.0 -11.5 -32.3 -25.3
20 1 26.6 -7.0 17.7 -3.9 -23.1 -16.0 -16.0 -12.2 -32.3 -25.3
25 1 24.1 3.9 17.4 4.0 -10.7 -14.6 -7.7 -11.7 -19.9 -17.0
2 -----4.1 -7.9 -1.1 -5.1 --
30 to 45° 1 21.6 14.8 17.2 11.8 1.7 -13.1 0.6 -11.3 -7.6 -8.7
2 21.6 14.8 17.2 11.8 8.3 -6.5 7.2 -4.6 -7.6 -8.7
1 20.45 -9.48 13.58 -5.54 -23.10 -13.62 -16.00 -10.46 -32.30 -25.30
2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
- building must be regular shaped low-rise building
as defined in Section 26.2
7.59
- Building is not sited at a location where
channeling effects or buffeting in the wake of
upwind obstructions need to be considered.
Simplified Design Wind Pressure, Ps30 (psf) (Exposure B at h = 30 ft., Kzt =1.0)
Basic Wind
Speed (mph)
Roof Angle
(degrees)Load Case
- Building does not have complex response
characteristics (vortex chedding, etc);
Zones
Horizontal Pressures Vertical Pressures Overhangs
H1
H2
H3
H4
m n
W
MWFRS Wind Pressures Page 1 of 2 ASCE 7-10 MWFRS - Envel Proced Part 2 - JURASSIC Gift Shop 11/29/2023
Project JURASSIC CREEK
Job No.Gift Shop
By EAS
Date 11/29/23
Sheet _____ of ______
NBSD-Software.Com
MAIN WIND FORCE RESISTING SYSTEMS - WALLS AND ROOF
ASCE 7-10 WIND PROVISIONS - CHAPTER 28 - ENVELOPE PROCEDURE PART 2 - ENCLOSED SIMPLE DIAPHRAGM LOW-RISE BUILDINGS
ENCLOSED COMMERCIAL BUILDING - SAMPLE PROJECT, ANYTOWN
Requirements :- Building has Simple Diaphragms per Section 26.2
ASCE 7-10 Figure 28.6-1
- building must be regular shaped low-rise building
as defined in Section 26.2
- Building is not sited at a location where
channeling effects or buffeting in the wake of
upwind obstructions need to be considered.
- Building does not have complex response
characteristics (vortex chedding, etc);
H1
H2
H3
H4
m n
W
3. Wind Pressure Values from ASCE 7-10 Figure 28.6-1, at Basic Wind Speed (Cont)
b) Wind Pressures ps on MWFRS
A B* C D* E F G H EOH GOH
1 24.74 -11.47 16.43 -6.70 -27.95 -16.48 -19.36 -12.66 -39.08 -30.61
2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
A B* C D* E F G H
EOH GOH
ps (Psf)1 23.23 -12.10 15.37 -7.14 -27.95 -15.85 -19.36 -12.22 -39.08 -30.61
Notes:1. For Longitudinal MWFRS, use θ = 0°, and locate Zone E/F and G/H boundary at mid length of building.
2. Horizontal and Vertical pressures shown represent the sum of internal and external pressures.
3*. Per Note 7, the total horizontal load must not be less than that determined by assuming p s = 0 in Zones B and D.
4. The minimum wind load case of 28.6.4 must also be considered, as follows:
A B*C D*E F G H
ps (Psf)16.00 8.00 16.00 8.00 0.00 0.00 0.00 0.00
Extent of Loading:
a = MAX { MIN (10% Least Dimension, 40% Eave Height), 4% Least Dimension or 3.0'}Where 10% Least Dimension = 3.00 feet
40% Eave Height = 0.40 Hmr =6.00 feet
Therefore a = 3.00 feet (See note 9 in Figure 28.6-1) 4% Least Dimension, or 3 ft = 3.00 feet
2a = 6.00 feet
Horizontal Pressures Vertical Pressures
Load Case Horizontal Pressures Vertical Pressures
Horizontal Pressures Vertical PressuresLoad Case
Overhangs
Transverse Loading (Case A)
Longitudinal Loading (Case B)
Overhangs
ps (Psf)
MWFRS Wind Pressures Page 2 of 2 ASCE 7-10 MWFRS - Envel Proced Part 2 - JURASSIC Gift Shop 11/29/2023
Project Analysis Worksheet
Structural Calculations
Lateral Distribution
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Gift Shop CHECKED EAS
Project No.:02-23-006 DATE: 11/22/2023
Project Location
Risk Category per ASCE 7 =II Exposure =C Site Class =D
Wind Speed =90 Importance Factor Iw =1.00 Roof DL =15 psf
Bldg/Area Length, L =60 ft Overall Structure Height =15.0 ft Ground Snow Load (Pg) =50 psf
Bldg/Area Width, W =30 ft Plate Height = 10.0 ft Percent Seismic (Pg) =20%
Edge Strip (a)=3 ft Wall Weight = 20.0 psf Ss =36.9%g
End Zone (2a)=6 ft R = 6.5 S1 =14.1%g
Roof Type (receiving wind) = Roof Type (receiving wind) =Gable End
Use Only End Zone Pressures = Use Only End Zone Pressures =N
Interior Pressure (psf) (T-H-C)= Interior Pressure (psf) (L-H-C) =15.4
Roof Interior Pressure (psf) (T-H-D)= Roof Interior Pressure (psf) =-6.7
End Zone Pressure (psf) (T-H-A) = End Zone Pressure (psf) (L-H-A)=23.2
Roof End Zone Pressure (psf) (T-H-B)= Roof End Zone Pressure (psf) =-11.5
Wind Lateral Load Vertical Distribution:
Transverse Force
Level hi (ft) di (ft) wx-end zone (plf) wx-min (plf) wx-avg (plf) Fx (kip)
1st 10 5 247 160 181 LRFD 10.9
Longitudinal Force
Level hi (ft) di (ft) wx-end zone (plf) wx-min (plf) wx-avg (plf) Fx (kip)
1st 10 5 232 160 169 LRFD 5.1
Seismic Lateral Loading:ASCE 7-16
SMS = 0.555g CS = 0.057 T = 0.133 T0 = 0.118
SDS = 0.370g Cs-max = 0.252 Ta = 0.133 TS = 0.589
SM1 = 0.33g Cs-min = 0.016 Tmax = 0.186 Sa = 0.370
SD1 = 0.218g CS (controls)= 0.057 CU = 1.4 k = 1.00
TL =6 Fv = 2.32 Roof Area = 1984
Ct =0.020 Fa = 1.50 Seismic Weight = 67.6
x =0.750 V = 3.8
Seismic Lateral Distribution:
Level hx (ft) wx (kip)wx hx
k (kip-ft)Cvx Fx (kip) Vx (kip)
1st 12.5 67.6 845 1.000 3.8 LRFD 3.8
Total Lateral Distribution: ASD
Wind = 3050
Seismic = 2695
Wind = Seismic =
6513 2695
pounds pounds
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Gift Shop Calcs/[PAW_Lateral Distribution - JURASSIC CGift Shop.xlsx]Lateral Distribution
-11.5
Lateral Loading:
Wind Lateral Pressures:
Longitudinal Direction (parallel to L):Transverse Direction (normal to L):
Gable End
N
16.4
-6.7
pounds 30 ft.
60 ft.
154
wx-interior (plf)
pounds
wx-interior (plf)
164
24.7
Project Analysis Worksheet
Structural Calculations
Shear Wall
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Gift Shop CHECKED EAS
Project No.:02-23-006 DATE: 11/22/2023
Project Location
Line = ASD Seismic =1347.5 lbs
ASD Wind =3256.5 lbs
Roof DL =15 psf
Wall DL = 15 psf
Sds =0.37 g
Seismic:
Wall Segment = 4
Height (ft) = total:
Length (ft) = 18.5
Roof Trib (psf) =
aspect ratio
aspect ratio factor total:
Effective Length 18.5
Seismic:
F =
shear =
Moment =
DL factor 1 =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wind:
F =
shear =
Moment =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wall Results:
Wall Length = ft ft ft ft
Max Seismic Shear = plf plf plf plf
Max Wind Shear = plf plf plf plf
Max Compression Seismic= lbs lbs lbs lbs
Max Compression Wind= lbs lbs lbs lbs
Max Uplift Seismic = lbs lbs lbs lbs
Max Uplift Wind = lbs lbs lbs lbs
Shear wall Type :D
APA Rated Sheating (in.): 7/16
Blocking: Unblocked
Edge Nailing (8d O.C.): 6 in.
Field Nailing (8d O.C.): 6 in.
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Gift Shop Calcs/[PAW_Shear Wall - JURASSIC Gift Shop.xlsx]A.1
12
18.5
A.1
1 2 3
1
18.5
12
0.6
16170.0
1.0518
1347.5
72.8
0.5482
197.352
378.648
2080.3
176.0
39078.0
0.0
3256.5
0.60
216
360
3221.3
72.8
OK
non req
18.5
3221.3
2080.3
176.0
OK
B D D
0.0
non req
6 in. 6 in. 6 in.
12 in. 6 in. 6 in.
7/16 7/16 7/16
Unblocked Unblocked Unblocked
Project Analysis Worksheet
Structural Calculations
Shear Wall
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Gift Shop CHECKED EAS
Project No.:02-23-006 DATE: 11/22/2023
Project Location
Line = ASD Seismic =1347.5 lbs
ASD Wind =3256.5 lbs
Roof DL =15 psf
Wall DL = 15 psf
Sds =0.37 g
Seismic:
Wall Segment = 4
Height (ft) = total:
Length (ft) = 30
Roof Trib (psf) =
aspect ratio
aspect ratio factor total:
Effective Length 30
Seismic:
F =
shear =
Moment =
DL factor 1 =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wind:
F =
shear =
Moment =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wall Results:
Wall Length = ft ft ft ft
Max Seismic Shear = plf plf plf plf
Max Wind Shear = plf plf plf plf
Max Compression Seismic= lbs lbs lbs lbs
Max Compression Wind= lbs lbs lbs lbs
Max Uplift Seismic = lbs lbs lbs lbs
Max Uplift Wind = lbs lbs lbs lbs
Shear wall Type :F
APA Rated Sheating (in.): 7/16
Blocking: Blocked
Edge Nailing (8d O.C.): 4 in.
Field Nailing (8d O.C.): 12 in.
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Gift Shop Calcs/[PAW_Shear Wall - JURASSIC Gift Shop.xlsx]A.2
12
30
A.1
1 2 3
1
30
18
0.4
16170.0
1.0518
1347.5
44.9
0.5482
246.69
473.31
2000.6
108.6
39078.0
0.0
3256.5
0.60
270
450
2667.4
44.9
OK
0.0
30
2667.4
2000.6
108.6
OK
B B F
0.0
0.0
6 in. 6 in. 4 in.
12 in. 12 in. 12 in.
7/16 7/16 7/16
Unblocked Unblocked Blocked
Project Analysis Worksheet
Structural Calculations
Shear Wall
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Gift Shop CHECKED EAS
Project No.:02-23-006 DATE: 11/22/2023
Project Location
Line = ASD Seismic =1347.5 lbs
ASD Wind =1525 lbs
Roof DL =15 psf
Wall DL = 15 psf
Sds =0.37 g
Seismic:
Wall Segment = 4
Height (ft) = total:
Length (ft) = 35
Roof Trib (psf) =
aspect ratio
aspect ratio factor total:
Effective Length 35
Seismic:
F =
shear =
Moment =
DL factor 1 =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wind:
F =
shear =
Moment =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wall Results:
Wall Length = ft ft ft ft
Max Seismic Shear = plf plf plf plf
Max Wind Shear = plf plf plf plf
Max Compression Seismic= lbs lbs lbs lbs
Max Compression Wind= lbs lbs lbs lbs
Max Uplift Seismic = lbs lbs lbs lbs
Max Uplift Wind = lbs lbs lbs lbs
Shear wall Type :D
APA Rated Sheating (in.): 7/16
Blocking: Unblocked
Edge Nailing (8d O.C.): 6 in.
Field Nailing (8d O.C.): 6 in.
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Gift Shop Calcs/[PAW_Shear Wall - JURASSIC Gift Shop.xlsx]B.1
6 in. 6 in. 6 in.
12 in. 6 in. 6 in.
7/16 7/16 7/16
Unblocked Unblocked Unblocked
B D D
0.0
0.0
1248.8
1241.5
43.6
OK
38.5
OK
0.0
35
0.60
144
240
1248.8
43.6
18300.0
0.0
1525.0
0.5482
131.568
252.432
1241.5
16170.0
1.0518
1347.5
38.5
1
35
4
0.3
12
35
B.1
1 2 3
Project Analysis Worksheet
Structural Calculations
Shear Wall
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Gift Shop CHECKED EAS
Project No.:02-23-006 DATE: 11/22/2023
Project Location
Line = ASD Seismic =1347.5 lbs
ASD Wind =1525 lbs
Roof DL =15 psf
Wall DL = 15 psf
Sds =0.37 g
Seismic:
Wall Segment = 4
Height (ft) =10 total:
Length (ft) =5 25
Roof Trib (psf) = 4
aspect ratio 2.0
aspect ratio factor 1 total:
Effective Length 5 23.33333333
Seismic:
F = 288.8
shear = 57.8
Moment = 2887.5
DL factor 1 = 1.0518
wDL = 220.878
Compression = 1291.1
DL factor 2 = 0.5482
wDL = 115.122
Uplift = non req
Wind:
F = 326.8
shear = 65.4
Moment = 3267.9
wDL = 210
Compression = 1219.2
DL factor 2 = 0.60
wDL = 126
Uplift = non req
Wall Results:
Wall Length = ft ft ft 5 ft
Max Seismic Shear = plf plf plf 57.8 plf
OK
Max Wind Shear = plf plf plf 65.4 plf
OK
Max Compression Seismic= lbs lbs lbs 1291.1 lbs
Max Compression Wind= lbs lbs lbs 1291.1 lbs
Max Uplift Seismic = lbs lbs lbs non req lbs
Max Uplift Wind = lbs lbs lbs non req lbs
Shear wall Type :B
APA Rated Sheating (in.): 7/16
Blocking: Unblocked
Edge Nailing (8d O.C.): 6 in.
Field Nailing (8d O.C.): 12 in.
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Gift Shop Calcs/[PAW_Shear Wall - JURASSIC Gift Shop.xlsx]B.2
15 15 10
10 5 5
B.2
1 2 3
1 0.66666667 1
10 3.33333333 5
4 4 4
1.5 3.0 2.0
8662.5 2887.5 2887.5
1.0518 1.0518 1.0518
577.5 192.5 288.8
57.8 38.5 57.8
0.5482 0.5482 0.5482
156.237 156.237 115.122
299.763 299.763 220.878
1883.2 1516.5 1291.1
65.4 43.6 65.4
9803.6 3267.9 3267.9
non req non req non req
653.6 217.9 326.8
0.60 0.60 0.60
171 171 126
285 285 210
1866.5 1413.2 1219.2
57.8 38.5 57.8
OK OK OK
non req non req non req
10 5 5
1883.2 1516.5 1291.1
1883.2 1516.5 1291.1
65.4 43.6 65.4
OK OK OK
B B B
non req non req non req
non req non req non req
6 in. 6 in. 6 in.
12 in. 12 in. 12 in.
7/16 7/16 7/16
Unblocked Unblocked Unblocked
Cy Hepworth Structural Calculations Package
Jurassic Creek Project No. 02-23-006
Civilize, PLLC | P a g e
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Calcs Package-
Hepworth.docx
JURASSIC CREEK
RESTROOMS
JURASSIC CREEK RESTROOM KEY PLAN
SCALE: NTS
A.
1
B.1
Se
i
s
m
i
c
=
9
6
1
.
5
Wi
n
d
=
2
0
2
0
Seismic = 961.5
Wind = 1944
A.
2
Se
i
s
m
i
c
=
9
6
1
.
5
Wi
n
d
=
2
0
2
0
B.2 Seismic = 949
Wind = 2271
7/
1
6
U
N
B
L
O
C
K
E
D
6 I
N
E
D
G
E
12
I
N
F
I
E
L
D
7/
1
6
U
N
B
L
O
C
K
E
D
6 I
N
E
D
G
E
12
I
N
F
I
E
L
D
7/16 UNBLOCKED
6 IN EDGE
12 IN FIELD
7/16 UNBLOCKED
6 IN EDGE
12 IN FIELD
B1
(2) 1.75X9.25 2.0E LVL
B2 B2
B3
P1
4X
4
D
F
#
2
P4
4X
4
D
F
#
2
2X6 DF #2 @ 24" O.C.
B3B4
J1
(2) 2X8 DF #2 (2) 2X8 DF #2
3.125X9 24F-V4 GLB
P3
4X
4
D
F
#
2
P2
4X
4
D
F
#
2
Cy Hepworth Structural Calculations Package
Jurassic Creek Project No. 02-23-006
Civilize, PLLC | P a g e
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Calcs Package-
Hepworth.docx
JURASSIC CREEK
RESTROOMS
GRAVITY DESIGN
Project Analysis Worksheet
Structural Calculations
Continuous Footing
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Restroom CHECKED EAS
Project No.:02-23-006 DATE: 11/22/2023
Description:
Soil Bearing Pressure (q) =1500 psf
Allowable Soil Bearing (qu) =2128 psf qmin =100.89 psf
Soil Bearing Pressure (qmax)=1211 psf OK
Tributary Length (ft) P Dead (lbs/ft) P Live (lbs/ft) Pu (lbs/ft)
Roof Loading:20 300.00 700.00 1480.00
Floor Loading:0 0.00 0.00 0.00
Wall Loading:14 280.00 0.00 336.00
Total Loads(lbs/ft) =580.00 700.00 1816.00
Ultimate Ratio = 1.42
Footing Dimensions
Width = inches Width =8 inches
Thickness = inches Height 36 inches
Max Point Load on Stem Wall (Pmax) =17,625.0 lbs
Max Point Load at opening (Pmax) =12,611.7 lbs
Continuous Reinforcing area of bar(in^2) =0.20 Min p =0.0018
Rebar Size =#4 fy = psi bar diameter(in) =0.50 Max p =0.0134
f'c = psi Total Bars =2 Use p =0.0018
B1 =0.85 As req(in^2)=0.2592
8 inches
Stemwall Height =36 Footing Thickness =8 inches
(2)#4
18 inches
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Restroom Calcs/[PAW Cont Foot - JURASSIC RR.xlsx]Footing 1
Soil Conditions:
Footing and Stem Wall Dimensions:
Loading:
Dead Load (lbs) Live Load (lbs)
15 35
2500
0 0
20 0
Stemwall Dimensions
18
8
Footing Rebar:
60000
Footing Design
Stemwall Width =
inches
Continuous Rebar
Footing Width =
Concrete Pad Footing
Strength Design per ACI 318-11
Mark: SonoTube:
inches
Material Data
P Self (k) =0.77 M DL (k-ft) =0.00 Allowable q (psf) =1500
P DL (k) =0.50 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85
P LL (k) =1.19 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40
Pu (k) =3.4 Mu (k-ft) =0.00 Bars #4 and bigger, Fy (ksi) = 60
e (ft) = 0.00
within middle 3rd
Footing Dimensions: Column/Pier Base: Shear Check:
Long (ft) =1.33 Long Direction (in) =12 Punching Vc (psi) = 170
Short (ft) =1.33 Short Direction (in)=12 Wide Bm Vc (psi) = 85
Thickness (in) =36 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in)
% in center band B=100% 2784 >-414 OK
Punching Shear Resistance (k) > Applied Force (k)
Bearing Pressures:997 >-24 OK
q min (psf) =1390 q max (psf) =1390 OK
qu-max (psf) =1937 qu at edge of base (psf) =1937
qu-min (psf) =1937 qu at edge of base (psf) =1937
Reinforcing:
Reinforcement Top and Bottom(Y/N) =N
Base As(min) on calc'd As(4/3) (Y/N) =Y
Check Development Length
L' long (ft) = 0.16 Bar size =#4 p =0.0000 Fy (psi) = 60000
Mu (k-ft) = 0.03 area of bar = 0.20 Min p =0.0000 Ld1 (in) =24.0
d (in)= 32.75 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12
As req(in^2/ft)= 0.00 Spacing (in) = 10100 Use p =0.0000 Ld3 (in) =12
Total Bars = 1 Less than pmax, OK Available Ld (in) = 43.7 OK
Check Development Length
L' short (ft) = 0.16 Bar size =#4 p =0.0000 Fy (psi) = 60000
Mu (k-ft) = 0.01 area of bar = 0.20 Min p =0.0000 Ld1 (in) =24.0
d (in)= 32.25 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12
As req(in^2/ft)= 0.00 Spacing (in) = 20200 Use p =0.0000 Ld3 (in) =12
Total Bars = 1 Less than pmax, OK Available Ld (in) = 43.2 OK
P1 - Restroom Use:
w/ 1 #4
1.3 feet long x 1.3 feet wide x 36'' thick Footing
Each Way
Short Direction Check p
P1 - Restroom 18
Loads: (U = 1.2DL + 1.6LL)
Long Direction Check p
Project Jurassic Creek 0.00
Job No.Restrooms 0.00
By 0.00 0.00
Date 11/29/23 0.00
Sheet _____ of ______
NBSD-Software.Com
DRIFTS ON ROOF PROJECTIONS AND PARAPETS
ASCE 7-10 CHAPTER 7 - SNOW LOADS
COMMERCIAL BUILDING - SAMPLE PROJECT, ANYTOWN
1. Snow Parameter Data
Building Parameters
L =35.00 feet (Length of Building)
W =35.00 feet (Width of Building)
Hp =4.00 feet (Height of parapet)
Snow Design Parameters Note: Tables and Figures provided courtesy of American Society of Civil Engineers (ASCE).
Occupancy:II (ASCE 7-10 Table 1.5-1)
Fully
Exposed
Partially
Exposed Sheltered
pg =50 B 0.9 1.0 1.2
C 0.9 1.0 1.1
EXP =B (Exposure Category, ASCE 7-10 Chapt 26.7)D 0.8 0.9 1.0
Above the treeline in widswept mountainous areas 0.7 0.8 N/A
Note:
House Structure
Kept at
Room Temp
Kept Above
Freezing Unheated
Greenhous
e with
Insulation
Thermal
Condition x
Note:
Fully
Exposed
Partially
Exposed Sheltered
Roof Condition x
2. Determination of Flat Roof Snow Load, Pf (Section 7.3)
Pf = 0.7 Cs Ct Is Pg (7.3-1)Where Ce =0.9 lb/ft2 (Exposure Factor, from Figure 7-2)
Ct =1.10 (Thermal Factor, Table 7-3)
I =1.00 (Importance factor, from ASCE 7-10 Table 1.5-2)
pg =50 lb/ft2 (Ground Snow Load, from Figure 7-1)
Pf =34.65 psf
3. Determination of Drift Loads (7.7)
a) Determination of Snow Density
γ = 0.13 Pg + 14 < 30 pcf (7.7-1)
Where pg =50 psf
γ = 20.50 pcf
b) Determination of Clear Height, hc
hc = Hp - hb Where Hp =4.00 feet (Height of parapet)
hb = pf / γ and pf =34.65 psf (Flat roof snow load)
γ = 20.50 pcf
hb = 1.69 feet (height of balanced snow load)
hc =2.31 feet
Chapter 26.7
N Above the treeline in widswept mountainous areas
(Y or N) ?
In Alaska, in areas where trees do not exist within a 2-
mile radius of the site
Table 7-2 Exposure Factor, Ce
Terrain Category
lb/ft2 (Ground Snow Load, from
Figure 7-1)
Chapter 26.7
Chapter 26.7
Slippery Non-Slippery
0.7 0.8 N/A
N In Alaska, in areas where trees do not exist within a
2-mile radius of the site (Y or N) ?
Roof Surface
x
Metal, Slate, glass,
bituminous, rubber,
plastic surfaces with a
smooth surface.
Membranes with
imbedded aggregate or
mineral granule surface,
asphalt shingles, wood
shingles, shakes.
p s f 2 0 Pf o r 2 0 g
Hp
Page 1 of 2 Snow Loads - Parapets - ASCE 7-10 Gravity Loads - JURASSIC RR 11/29/2023
Project Jurassic Creek 0.00
Job No.Restrooms 0.00
By 0.00 0.00
Date 11/29/23 0.00
Sheet _____ of ______
NBSD-Software.Com
DRIFTS ON ROOF PROJECTIONS AND PARAPETS
ASCE 7-10 CHAPTER 7 - SNOW LOADS
COMMERCIAL BUILDING - SAMPLE PROJECT, ANYTOWN
1. Snow Parameter Data
Building Parameters
L =35.00 feet (Length of Building)
W =35.00 feet (Width of Building)
Hp =4.00 feet (Height of parapet)
Hp
d) Determine if Drift Loads are Required (7.7.1)
Note:If hc/hb < 0.2, drift loads are not required to be applied, where hc =2.31 feet
hb =1.69 feet
hc/hb =1.37
Drift loads must be considered!
a) Drift along Length of Building
4. Drift Loads on Roof Projections (Sect 7.7)
Pd = 37.13 psf Pf = 34.7 psf
a) Drift along Length of Building
1.81'
Lu = L =35 ft (Length of building)
pg =50 lb/ft2 (Ground Snow Load, from Figure 7-1)
0.75 hd =1.81 feet
w = 7.24'
Drift Width
<= Governs! Where hd =1.81 feet
hc =2.31 feet
Thus, w =7.24 feet
hd =1.81 feet
Maximum Intensity of Drift Surcharge Load b) Drift along Width of Building
Pd = hd γ Where hd =1.81 feet Pd = 37.13 psf Pf = 34.7 psf
γ = 20.50 pcf
Pd =37.1 psf 1.81'
b) Drift along Width of Building
Lu = L =35 ft (Length of building)w = 7.24'
pg =50 lb/ft2 (Ground Snow Load, from Figure 7-1)
0.75 hd =1.81 feet
Drift Width
<= Governs! Where hd =1.81 feet
hc =2.31 feet
Thus, w =7.24 feet
hd =1.81 feet
Maximum Intensity of Drift Surcharge Load
Pd = hd γ Where hd =1.81 feet
γ = 20.50 pcf
Pd =37.1 psf
(7.7.1) 1.5 - 10 p L 0.43 0.75 h 0.75 4 g3ud
dddcdh 4 wand h h ,h h If
h 8 h
h 4 wand h h ,h h If c
c
2
d
cdcd
(7.7.1) 1.5 - 10 p L 0.43 0.75 h 0.75 4 g3ud
dddcdh 4 wand h h ,h h If
h 8 h
h 4 wand h h ,h h If c
c
2
d
cdcd
Page 2 of 2 Snow Loads - Parapets - ASCE 7-10 Gravity Loads - JURASSIC RR 11/29/2023
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2383 @ 1 1/2"11813 (3.00")Passed (20%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)2009 @ 1' 1/4"10611 Passed (19%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)7451 @ 6' 6"19327 Passed (39%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.238 @ 6' 6"0.425 Passed (L/643)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.332 @ 6' 6"0.637 Passed (L/460)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 3.00"3.00"1.50"677 1706 2383 None
2 - Trimmer - DF 3.00"3.00"1.50"677 1706 2383 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)13' o/c
Bottom Edge (Lu)13' o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 13'N/A 14.2 --
1 - Uniform (PSF)0 to 13'7' 6"12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B1
3 piece(s) 1 3/4" x 9 1/4" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 11/29/2023 11:52:17 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Restroom
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1449 @ 1 1/2"5625 (3.00")Passed (26%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)742 @ 10 1/4"3002 Passed (25%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)1093 @ 1' 9"2720 Passed (40%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.010 @ 1' 9"0.108 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.014 @ 1' 9"0.162 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 3.00"3.00"1.50"377 1072 1449 None
2 - Trimmer - DF 3.00"3.00"1.50"377 1072 1449 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3' 6" o/c
Bottom Edge (Lu)3' 6" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 3' 6"N/A 5.5 --
1 - Uniform (PSF)0 to 3' 6"17' 6"12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B2
2 piece(s) 2 x 8 DF No.2
ForteWEB Software Operator Job Notes 11/29/2023 11:52:17 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Restroom
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)565 @ 2"4648 (3.50")Passed (12%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)435 @ 1' 1/2"5714 Passed (8%)1.15 1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)1190 @ 4' 6 1/2"9703 Passed (12%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.034 @ 4' 6 1/2"0.292 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.048 @ 4' 6 1/2"0.438 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 8' 9".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Stud wall - SPF 3.50"3.50"1.50"167 397 565 Blocking
2 - Stud wall - SPF 3.50"3.50"1.50"167 397 565 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)9' 1" o/c
Bottom Edge (Lu)9' 1" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 9' 1"N/A 6.8 --
1 - Uniform (PSF)0 to 9' 1" (Front)2' 6"12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B3
1 piece(s) 3 1/8" x 9" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 11/29/2023 11:52:17 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Restroom
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)1124 @ 2"4648 (3.50")Passed (24%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)995 @ 1' 1/2"5714 Passed (17%)1.15 1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)4897 @ 9' 1/2"9703 Passed (50%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.572 @ 9' 1/2"0.592 Passed (L/372)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.813 @ 9' 1/2"0.887 Passed (L/262)--1.0 D + 1.0 S (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 17' 9".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Stud wall - SPF 3.50"3.50"1.50"333 791 1124 Blocking
2 - Stud wall - SPF 3.50"3.50"1.50"333 791 1124 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)18' 1" o/c
Bottom Edge (Lu)18' 1" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 18' 1"N/A 6.8 --
1 - Uniform (PSF)0 to 18' 1" (Front)2' 6"12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B4
1 piece(s) 3 1/8" x 9" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 11/29/2023 11:52:17 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Restroom
Post Height: 8'
Design Results Actual Allowed Result LDF Load: Combination
Slenderness 27 50 Passed (55%)----
Compression (lbs)564 7605 Passed (7%)1.15 1.0 D + 1.0 S
Base Bearing (lbs)564 363825 Passed (0%)--1.0 D + 1.0 S
Bending/Compression 0.03 1 Passed (3%)1.15 1.0 D + 1.0 S
•Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
•Applicable calculations are based on NDS.
Supports Type Material
Base Plate Steel
Max Unbraced Length Comments
Full Member Length No bracing assumed.
Member Type : Free Standing Post
Building Code : IBC 2018
Design Methodology : ASD
Dead Snow
Vertical Load (0.90)(1.15)Comments
1 - Point (lb)167 397 Linked from: B3, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
Drawing is Conceptual
MEMBER REPORT PASSED
Level, P1
1 piece(s) 4 x 4 DF No.1
ForteWEB Software Operator Job Notes 11/29/2023 11:52:17 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Restroom
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)258 @ 5' 3 1/2"1406 (1.50")Passed (18%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)214 @ 4' 10 5/16"1139 Passed (19%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)328 @ 2' 9"975 Passed (34%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.035 @ 2' 9"0.268 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.051 @ 2' 9"0.357 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Roof
Member Type : Joist
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 4/12
•Deflection criteria: LL (L/240) and TL (L/180).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•A 15% increase in the moment capacity has been added to account for repetitive member usage.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ¹ See Connector grid below for additional information and/or requirements.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Beveled Plate - DF 3.50"3.50"1.50"87 193 279 Blocking
2 - Hanger on 5 1/2" DF Ledger 3.50"Hanger¹1.50"89 198 287 See note ¹
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 7" o/c
Bottom Edge (Lu)5' 7" o/c
Connector: Simpson Strong-Tie
Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories
2 - Face Mount Hanger LRU26Z 1.94"N/A 4-10dx1.5 5-10d
•Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead Snow
Vertical Load Location (Side)Spacing (0.90)(1.15)Comments
1 - Uniform (PSF)0 to 5' 7"24"15.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.Member Length : 5' 8 3/4"
MEMBER REPORT PASSED
Level, J1
1 piece(s) 2 x 6 DF No.2 @ 24" OC
ForteWEB Software Operator Job Notes 11/29/2023 11:52:17 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Restroom
Post Height: 8'
Design Results Actual Allowed Result LDF Load: Combination
Slenderness 27 50 Passed (55%)----
Compression (lbs)1688 7605 Passed (22%)1.15 1.0 D + 1.0 S
Base Bearing (lbs)1688 363825 Passed (0%)--1.0 D + 1.0 S
Bending/Compression 0.15 1 Passed (15%)1.15 1.0 D + 1.0 S
•Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
•Applicable calculations are based on NDS.
Supports Type Material
Base Plate Steel
Max Unbraced Length Comments
Full Member Length No bracing assumed.
Member Type : Free Standing Post
Building Code : IBC 2018
Design Methodology : ASD
Dead Snow
Vertical Loads (0.90)(1.15)Comments
1 - Point (lb)167 397 Linked from: B3, Support 1
2 - Point (lb)333 791 Linked from: B4, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
Drawing is Conceptual
MEMBER REPORT PASSED
Level, P2
1 piece(s) 4 x 4 DF No.1
ForteWEB Software Operator Job Notes 11/29/2023 11:52:17 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Restroom
Post Height: 8'
Design Results Actual Allowed Result LDF Load: Combination
Slenderness 27 50 Passed (55%)----
Compression (lbs)1688 7605 Passed (22%)1.15 1.0 D + 1.0 S
Base Bearing (lbs)1688 363825 Passed (0%)--1.0 D + 1.0 S
Bending/Compression 0.15 1 Passed (15%)1.15 1.0 D + 1.0 S
•Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
•Applicable calculations are based on NDS.
Supports Type Material
Base Plate Steel
Max Unbraced Length Comments
Full Member Length No bracing assumed.
Member Type : Free Standing Post
Building Code : IBC 2018
Design Methodology : ASD
Dead Snow
Vertical Loads (0.90)(1.15)Comments
1 - Point (lb)167 397 Linked from: B3, Support 1
2 - Point (lb)333 791 Linked from: B4, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
Drawing is Conceptual
MEMBER REPORT PASSED
Level, P3
1 piece(s) 4 x 4 DF No.1
ForteWEB Software Operator Job Notes 11/29/2023 11:52:17 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Restroom
Post Height: 8'
Design Results Actual Allowed Result LDF Load: Combination
Slenderness 27 50 Passed (55%)----
Compression (lbs)564 7605 Passed (7%)1.15 1.0 D + 1.0 S
Base Bearing (lbs)564 363825 Passed (0%)--1.0 D + 1.0 S
Bending/Compression 0.03 1 Passed (3%)1.15 1.0 D + 1.0 S
•Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
•Applicable calculations are based on NDS.
Supports Type Material
Base Plate Steel
Max Unbraced Length Comments
Full Member Length No bracing assumed.
Member Type : Free Standing Post
Building Code : IBC 2018
Design Methodology : ASD
Dead Snow
Vertical Load (0.90)(1.15)Comments
1 - Point (lb)167 397 Linked from: B3, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
Drawing is Conceptual
MEMBER REPORT PASSED
Level, P4
1 piece(s) 4 x 4 DF No.1
ForteWEB Software Operator Job Notes 11/29/2023 11:52:17 PM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: Restroom
Location:
Height (ft) =10.0 Gravity Loads to Wall:
Le/d = 21.8 < 50 OK DL(psf) trib(ft) w e(in)
deflection < L/240 roof snow 12 15 705 0
wind/seismic (W/S)W floor live load 0 0 0 0
wind load, w (psf) =30 (Due to Wind)wall weight 15 15 225
0.6 * w = (psf) 18.0 misc. live load 0 0 0 0
snow load? (Y/N)Y w (total uniform load) = 930 plf
Lumber Grade: (DF No. 2)
Load Cases:
CD =1.60 CD =1.60 CD =1.15
P (lbs) = 540 per stud P (lbs) = 525 P (lbs) = 1240 per stud
M (lb-ft) = 300 M (lb-ft) = 225 M (lb-ft) = 0
FcE (psi) =1002 FcE (psi) =1002 FcE (psi) =1002
Fc' (psi) = 894 Fc' (psi) = 894 Fc' (psi) = 839
fc (psi) = 65 < Fc'OK fc (psi) = 64 < Fc'OK fc (psi) = 150 < Fc'OK
Fb' (psi) = 2153 Fb' (psi) = 2153 Fb' (psi) = 1547
fb (psi) = 476 < Fb'OK fb (psi) = 357 < Fb'OK fb (psi) = 0 < Fb'OK
CSR = 0.24 < 1.0 OK CSR = 0.18 < 1.0 OK CSR = 0.03 < 1.0 OK
D (in.) =0.11 = L/1056 OK D (in.) =0.09 = L/1408 OK D (in.) =0.00 = L/5000 OK
USE:2 x 6
Framing at Openings:
Trimmers: King Studs:
Trimmer supports only vertical load ... King stud supports only bending ...
Pcap (lbs) = 6924 Mcap (lb-ft) = 1180
Rcap (lbs) = 5156
(bearing governs)trib width capacity (ft) = 5.24 for M < Mcap
(governs)
trib width capacity (ft) = 5.87 for D < L /240
Wood Stud Wall Design
Design based on NDS 2012
Trimmer Studs (TS) King Studs (KS)
at 16'' o.c.
D + S
Open Width (ft)
Typical 10'-0" Plate
0
LL(psf)
D + 0.6*W D + 0.75*(0.6*W + S + LL)
35
0
1
1
29'-1'' to 19'-7''
< 9'-1''
30'-1'' to 40'-7'' 4
3
1
1
4
2
1
11
1
1
319'-7'' to 30'-1''
1
1
(DF No. 2)Typical 10'-0" Plate
Cy Hepworth Structural Calculations Package
Jurassic Creek Project No. 02-23-006
Civilize, PLLC | P a g e
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Calcs Package-
Hepworth.docx
JURASSIC CREEK
RESTROOMS
LATERAL DESIGN
Project JURASSIC CREEK
Job No.Bathrooms
By EAS
Date 11/29/23
Sheet _____ of ______
NBSD-Software.Com
MAIN WIND FORCE RESISTING SYSTEMS - WALLS AND ROOF
ASCE 7-10 WIND PROVISIONS - CHAPTER 28 - ENVELOPE PROCEDURE PART 2 - ENCLOSED SIMPLE DIAPHRAGM LOW-RISE BUILDINGS
ENCLOSED COMMERCIAL BUILDING - SAMPLE PROJECT, ANYTOWN
Requirements :- Building has Simple Diaphragms per Section 26.2
ASCE 7-10 Figure 28.6-1
1. Building Parameters Please note:
Risk Category:II (ASCE 7-10 Table 1.5-1) ASCE 7-10 Figure 28.6-1 data and information provided for reference courtesy of
Site Data American Society of Civil Engineers (ASCE) and Structural Engineering Institute (SEI).
EXP =C (Exposure Category per ASCE 26.7.3)
V =90 mph (Basic Wind Speed, ASCE 7-10 Fig 26.5-1A)
Building Dimensions
Vertical:Horizontal:
H1 = 15.00 feet m = 17.50 feet Roof Angle θ = 0.00 degrees (Windward Side)
H2 = 0.00 feet n = 17.50 feet = 6.52 degrees (Leeward Side)
H3 = 13.00 feet
H4 = 2.00 feet Mean Roof Height (ASCE 7-10 Section 26.2):
W = 35.00 feet (Transverse building dimension)
Hmr = AVERAGE (He,Hmax), for θ >10 degrees, otherwise He
L = 35.00 feet (Longitudinal building dimension)
Where Hmax =15.00 ft (maximum elevation)
Heave =15.00 ft (Max Eave Height)
Hmr =15.00 ft (Mean Roof Height)
2. Wind Velocity Pressure (ASCE 7-10 28.6.3)
ps = λ Kzt Ps30 (EQ 28.6-1)
Where λ =1.21 (Adjustment Factor for Building Height and Exposure, per Fig 6-2, Exp C, H = 15 feet)
Kzt =1.00 (Topographic Factor per Figure 6-4 - No info provided on topography)
ps =1.21 * ps30 psf (Wind Velocity Pressure)
3. Wind Pressure Values from ASCE 7-10 Figure 28.6-1, at Basic Wind Speed
a) Wind Pressures ps30 on MWFRS
For θ =6.52 degrees (Windward Side)
A B C D E F G H EOH GOH
90 0 to 5°1 19.2 -10.0 12.7 -5.9 -23.1 -13.1 -16.0 -10.1 -32.3 -25.3
10 1 21.6 -9.0 14.4 -5.2 -23.1 -14.1 -16.0 -10.8 -32.3 -25.3
15 1 24.1 -8.0 16.0 -4.6 -23.1 -15.1 -16.0 -11.5 -32.3 -25.3
20 1 26.6 -7.0 17.7 -3.9 -23.1 -16.0 -16.0 -12.2 -32.3 -25.3
25 1 24.1 3.9 17.4 4.0 -10.7 -14.6 -7.7 -11.7 -19.9 -17.0
2 -----4.1 -7.9 -1.1 -5.1 --
30 to 45° 1 21.6 14.8 17.2 11.8 1.7 -13.1 0.6 -11.3 -7.6 -8.7
2 21.6 14.8 17.2 11.8 8.3 -6.5 7.2 -4.6 -7.6 -8.7
1 19.93 -9.70 13.22 -5.69 -23.10 -13.40 -16.00 -10.31 -32.30 -25.30
2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
- building must be regular shaped low-rise building
as defined in Section 26.2
6.52
- Building is not sited at a location where
channeling effects or buffeting in the wake of
upwind obstructions need to be considered.
Simplified Design Wind Pressure, Ps30 (psf) (Exposure B at h = 30 ft., Kzt =1.0)
Basic Wind
Speed (mph)
Roof Angle
(degrees)Load Case
- Building does not have complex response
characteristics (vortex chedding, etc);
Zones
Horizontal Pressures Vertical Pressures Overhangs
H1
H2
H3
H4
m n
W
MWFRS Wind Pressures Page 1 of 2 ASCE 7-10 MWFRS - Envel Proced Part 2 - JURASSIC RR 11/29/2023
Project JURASSIC CREEK
Job No.Bathrooms
By EAS
Date 11/29/23
Sheet _____ of ______
NBSD-Software.Com
MAIN WIND FORCE RESISTING SYSTEMS - WALLS AND ROOF
ASCE 7-10 WIND PROVISIONS - CHAPTER 28 - ENVELOPE PROCEDURE PART 2 - ENCLOSED SIMPLE DIAPHRAGM LOW-RISE BUILDINGS
ENCLOSED COMMERCIAL BUILDING - SAMPLE PROJECT, ANYTOWN
Requirements :- Building has Simple Diaphragms per Section 26.2
ASCE 7-10 Figure 28.6-1
- building must be regular shaped low-rise building
as defined in Section 26.2
- Building is not sited at a location where
channeling effects or buffeting in the wake of
upwind obstructions need to be considered.
- Building does not have complex response
characteristics (vortex chedding, etc);
H1
H2
H3
H4
m n
W
3. Wind Pressure Values from ASCE 7-10 Figure 28.6-1, at Basic Wind Speed (Cont)
b) Wind Pressures ps on MWFRS
A B* C D* E F G H EOH GOH
1 24.11 -11.73 15.99 -6.88 -27.95 -16.22 -19.36 -12.48 -39.08 -30.61
2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
A B* C D* E F G H
EOH GOH
ps (Psf)1 23.23 -12.10 15.37 -7.14 -27.95 -15.85 -19.36 -12.22 -39.08 -30.61
Notes:1. For Longitudinal MWFRS, use θ = 0°, and locate Zone E/F and G/H boundary at mid length of building.
2. Horizontal and Vertical pressures shown represent the sum of internal and external pressures.
3*. Per Note 7, the total horizontal load must not be less than that determined by assuming p s = 0 in Zones B and D.
4. The minimum wind load case of 28.6.4 must also be considered, as follows:
A B*C D*E F G H
ps (Psf)16.00 8.00 16.00 8.00 0.00 0.00 0.00 0.00
Extent of Loading:
a = MAX { MIN (10% Least Dimension, 40% Eave Height), 4% Least Dimension or 3.0'}Where 10% Least Dimension = 3.50 feet
40% Eave Height = 0.40 Hmr =6.00 feet
Therefore a = 3.50 feet (See note 9 in Figure 28.6-1) 4% Least Dimension, or 3 ft = 3.00 feet
2a = 7.00 feet
Horizontal Pressures Vertical Pressures
Load Case Horizontal Pressures Vertical Pressures
Horizontal Pressures Vertical PressuresLoad Case
Overhangs
Transverse Loading (Case A)
Longitudinal Loading (Case B)
Overhangs
ps (Psf)
MWFRS Wind Pressures Page 2 of 2 ASCE 7-10 MWFRS - Envel Proced Part 2 - JURASSIC RR 11/29/2023
Project Analysis Worksheet
Structural Calculations
Lateral Distribution
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Restroom CHECKED EAS
Project No.:02-23-006 DATE: 11/22/2023
Project Location
Risk Category per ASCE 7 =II Exposure =C Site Class =D
Wind Speed =90 Importance Factor Iw =1.00 Roof DL =15 psf
Bldg/Area Length, L =35 ft Overall Structure Height =15.0 ft Ground Snow Load (Pg) =50 psf
Bldg/Area Width, W =35 ft Plate Height = 10.0 ft Percent Seismic (Pg) =20%
Edge Strip (a)=3.5 ft Wall Weight = 20.0 psf Ss =36.9%g
End Zone (2a)=7 ft R = 6.5 S1 =14.1%g
Roof Type (receiving wind) = Roof Type (receiving wind) =Gable End
Use Only End Zone Pressures = Use Only End Zone Pressures =N
Interior Pressure (psf) (T-H-C)= Interior Pressure (psf) (L-H-C) =15.4
Roof Interior Pressure (psf) (T-H-D)= Roof Interior Pressure (psf) =-6.9
End Zone Pressure (psf) (T-H-A) = End Zone Pressure (psf) (L-H-A)=23.2
Roof End Zone Pressure (psf) (T-H-B)= Roof End Zone Pressure (psf) =-11.7
Wind Lateral Load Vertical Distribution:
Transverse Force
Level hi (ft) di (ft) wx-end zone (plf) wx-min (plf) wx-avg (plf) Fx (kip)
1st 10 5 241 160 192 LRFD 6.7
Longitudinal Force
Level hi (ft) di (ft) wx-end zone (plf) wx-min (plf) wx-avg (plf) Fx (kip)
1st 10 5 232 160 185 LRFD 6.5
Seismic Lateral Loading:ASCE 7-16
SMS = 0.555g CS = 0.057 T = 0.133 T0 = 0.118
SDS = 0.370g Cs-max = 0.252 Ta = 0.133 TS = 0.589
SM1 = 0.33g Cs-min = 0.016 Tmax = 0.186 Sa = 0.370
SD1 = 0.218g CS (controls)= 0.057 CU = 1.4 k = 1.00
TL =6 Fv = 2.32 Roof Area = 1369
Ct =0.020 Fa = 1.50 Seismic Weight = 48.2
x =0.750 V = 2.7
Seismic Lateral Distribution:
Level hx (ft) wx (kip)wx hx
k (kip-ft)Cvx Fx (kip) Vx (kip)
1st 12.5 48.2 603 1.000 2.7 LRFD 2.7
Total Lateral Distribution: ASD
Wind = 3888
Seismic = 1923
Wind = Seismic =
4040 1923
pounds pounds
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Restroom Calcs/[PAW_Lateral Distribution - JURASSIC RR.xlsx]Lateral Distribution
pounds
wx-interior (plf)
160
24.1
pounds 35 ft.
35 ft.
154
wx-interior (plf)
-11.7
Lateral Loading:
Wind Lateral Pressures:
Longitudinal Direction (parallel to L):Transverse Direction (normal to L):
Gable End
N
16.0
-6.9
Project Analysis Worksheet
Structural Calculations
Shear Wall
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Restrooms CHECKED EAS
Project No.:02-23-006 DATE: 11/29/2023
Project Location
Line = ASD Seismic =961.5 lbs
ASD Wind =2020 lbs
Roof DL =15 psf
Wall DL = 15 psf
Sds =0.37 g
Seismic:
Wall Segment = 4
Height (ft) = total:
Length (ft) = 35
Roof Trib (psf) =
aspect ratio
aspect ratio factor total:
Effective Length 35
Seismic:
F =
shear =
Moment =
DL factor 1 =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wind:
F =
shear =
Moment =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wall Results:
Wall Length = ft ft ft ft
Max Seismic Shear = plf plf plf plf
Max Wind Shear = plf plf plf plf
Max Compression Seismic= lbs lbs lbs lbs
Max Compression Wind= lbs lbs lbs lbs
Max Uplift Seismic = lbs lbs lbs lbs
Max Uplift Wind = lbs lbs lbs lbs
Shear wall Type :D
APA Rated Sheating (in.): 7/16
Blocking: Unblocked
Edge Nailing (8d O.C.): 6 in.
Field Nailing (8d O.C.): 6 in.
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Restroom Calcs/[PAW_Shear Wall - JURASSIC RR.xlsx]A.1
12
35
A.1
1 2 3
1
35
4
0.3
11538.0
1.0518
961.5
27.5
0.5482
131.568
252.432
1106.7
57.7
24240.0
0.0
2020.0
0.60
144
240
1419.3
27.5
OK
0.0
35
1419.3
1106.7
57.7
OK
B D D
0.0
0.0
6 in. 6 in. 6 in.
12 in. 6 in. 6 in.
7/16 7/16 7/16
Unblocked Unblocked Unblocked
Project Analysis Worksheet
Structural Calculations
Shear Wall
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Restrooms CHECKED EAS
Project No.:02-23-006 DATE: 11/29/2023
Project Location
Line = ASD Seismic =961.5 lbs
ASD Wind =2020 lbs
Roof DL =15 psf
Wall DL = 15 psf
Sds =0.37 g
Seismic:
Wall Segment = 4
Height (ft) = total:
Length (ft) = 35
Roof Trib (psf) =
aspect ratio
aspect ratio factor total:
Effective Length 35
Seismic:
F =
shear =
Moment =
DL factor 1 =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wind:
F =
shear =
Moment =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wall Results:
Wall Length = ft ft ft ft
Max Seismic Shear = plf plf plf plf
Max Wind Shear = plf plf plf plf
Max Compression Seismic= lbs lbs lbs lbs
Max Compression Wind= lbs lbs lbs lbs
Max Uplift Seismic = lbs lbs lbs lbs
Max Uplift Wind = lbs lbs lbs lbs
Shear wall Type :F
APA Rated Sheating (in.): 7/16
Blocking: Blocked
Edge Nailing (8d O.C.): 4 in.
Field Nailing (8d O.C.): 12 in.
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Restroom Calcs/[PAW_Shear Wall - JURASSIC RR.xlsx]A.2
12
35
A.1
1 2 3
1
35
4
0.3
11538.0
1.0518
961.5
27.5
0.5482
131.568
252.432
1106.7
57.7
24240.0
0.0
2020.0
0.60
144
240
1419.3
27.5
OK
0.0
35
1419.3
1106.7
57.7
OK
B B F
0.0
0.0
6 in. 6 in. 4 in.
12 in. 12 in. 12 in.
7/16 7/16 7/16
Unblocked Unblocked Blocked
Project Analysis Worksheet
Structural Calculations
Shear Wall
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Restrooms CHECKED EAS
Project No.:02-23-006 DATE: 11/29/2023
Project Location
Line = ASD Seismic =961.5 lbs
ASD Wind =1944 lbs
Roof DL =15 psf
Wall DL = 15 psf
Sds =0.37 g
Seismic:
Wall Segment = 4
Height (ft) = total:
Length (ft) = 35
Roof Trib (psf) =
aspect ratio
aspect ratio factor total:
Effective Length 35
Seismic:
F =
shear =
Moment =
DL factor 1 =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wind:
F =
shear =
Moment =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wall Results:
Wall Length = ft ft ft ft
Max Seismic Shear = plf plf plf plf
Max Wind Shear = plf plf plf plf
Max Compression Seismic= lbs lbs lbs lbs
Max Compression Wind= lbs lbs lbs lbs
Max Uplift Seismic = lbs lbs lbs lbs
Max Uplift Wind = lbs lbs lbs lbs
Shear wall Type :D
APA Rated Sheating (in.): 7/16
Blocking: Unblocked
Edge Nailing (8d O.C.): 6 in.
Field Nailing (8d O.C.): 6 in.
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Restroom Calcs/[PAW_Shear Wall - JURASSIC RR.xlsx]B.1
6 in. 6 in. 6 in.
12 in. 6 in. 6 in.
7/16 7/16 7/16
Unblocked Unblocked Unblocked
B D D
0.0
0.0
2003.6
1757.3
55.5
OK
27.5
OK
0.0
35
0.60
265.5
442.5
2003.6
55.5
23328.0
0.0
1944.0
0.5482
242.5785
465.4215
1757.3
11538.0
1.0518
961.5
27.5
1
35
17.5
0.3
12
35
B.1
1 2 3
Project Analysis Worksheet
Structural Calculations
Shear Wall
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Restrooms CHECKED EAS
Project No.:02-23-006 DATE: 11/29/2023
Project Location
Line = ASD Seismic =961.5 lbs
ASD Wind =1944 lbs
Roof DL =15 psf
Wall DL = 15 psf
Sds =0.37 g
Seismic:
Wall Segment = 4
Height (ft) = total:
Length (ft) = 22
Roof Trib (psf) =
aspect ratio
aspect ratio factor total:
Effective Length 22
Seismic:
F =
shear =
Moment =
DL factor 1 =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wind:
F =
shear =
Moment =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wall Results:
Wall Length = ft ft ft ft
Max Seismic Shear = plf plf plf plf
Max Wind Shear = plf plf plf plf
Max Compression Seismic= lbs lbs lbs lbs
Max Compression Wind= lbs lbs lbs lbs
Max Uplift Seismic = lbs lbs lbs lbs
Max Uplift Wind = lbs lbs lbs lbs
Shear wall Type :B
APA Rated Sheating (in.): 7/16
Blocking: Unblocked
Edge Nailing (8d O.C.): 6 in.
Field Nailing (8d O.C.): 12 in.
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Restroom Calcs/[PAW_Shear Wall - JURASSIC RR.xlsx]B.2
15 15
11 11
B.2
1 2 3
1 1
11 11
20 20
1.4 1.4
7211.3 7211.3
1.0518 1.0518
480.8 480.8
43.7 43.7
0.5482 0.5482
287.805 287.805
552.195 552.195
2451.4 2451.4
88.4 88.4
14580.0 14580.0
0.0 0.0
972.0 972.0
0.60 0.60
315 315
525 525
2945.1 2945.1
43.7 43.7
OK OK
0.0 0.0
11 11
2945.1 2945.1
2451.4 2451.4
88.4 88.4
OK OK
B B B
0.0 0.0
0.0 0.0
6 in. 6 in. 6 in.
12 in. 12 in. 12 in.
7/16 7/16 7/16
Unblocked Unblocked Unblocked
Cy Hepworth Structural Calculations Package
Jurassic Creek Project No. 02-23-006
Civilize, PLLC | P a g e
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Calcs Package-
Hepworth.docx
JURASSIC CREEK
CAFE
JURASSIC CREEK CAFE KEY PLAN
SCALE: NTS
B1
B3
A.
1
B.1
Se
i
s
m
i
c
=
5
5
0
Wi
n
d
=
1
1
1
1
Seismic = 550
Wind = 1937.5
A.
2
Se
i
s
m
i
c
=
5
5
0
Wi
n
d
=
1
1
1
1
B.2 Seismic = 550
Wind = 1937.5
ST
H
D
1
4
ST
H
D
1
4
ST
H
D
1
4
ST
H
D
1
4
ST
H
D
1
4
ST
H
D
1
4
B2
B4
B5 B5
7/
1
6
U
N
B
L
O
C
K
E
D
6 I
N
E
D
G
E
12
I
N
F
I
E
L
D
7/16 BLOCKED
6 IN EDGE
12 IN FIELD
(2
)
2
X
6
D
F
#
2
(2
)
2
X
6
D
F
#
2
(2) 1.75X7.25 2.0E LVL (2) 1.75X7.25 2.0E LVL
3.125X6 24F-V4 GLB 3.125X6 24F-V4 GLB
P1
4X
4
D
F
#
2
P2
4X
4
D
F
#
2
P3
4X
4
D
F
#
2
J1 2X6 DF #2 @ 24" O.C.
7/
1
6
U
N
B
L
O
C
K
E
D
6 I
N
E
D
G
E
12
I
N
F
I
E
L
D
7/
1
6
U
N
B
L
O
C
K
E
D
6 I
N
E
D
G
E
12
I
N
F
I
E
L
D
7/16 UNBLOCKED
6 IN EDGE
12 IN FIELD
Cy Hepworth Structural Calculations Package
Jurassic Creek Project No. 02-23-006
Civilize, PLLC | P a g e
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Calcs Package-
Hepworth.docx
JURASSIC CREEK
CAFE
GRAVITY DESIGN
Project Analysis Worksheet
Structural Calculations
Continuous Footing
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Café CHECKED EAS
Project No.:02-23-006 DATE: 11/28/2023
Description:
Soil Bearing Pressure (q) =1500 psf
Allowable Soil Bearing (qu) =2136 psf qmin =111.17 psf
Soil Bearing Pressure (qmax)=1334 psf OK
Tributary Length (ft) P Dead (lbs/ft) P Live (lbs/ft) Pu (lbs/ft)
Roof Loading:22.5 337.50 787.50 1665.00
Floor Loading:0 0.00 0.00 0.00
Wall Loading:14 280.00 0.00 336.00
Total Loads(lbs/ft) =617.50 787.50 2001.00
Ultimate Ratio = 1.42
Footing Dimensions
Width = inches Width =8 inches
Thickness = inches Height 36 inches
Max Point Load on Stem Wall (Pmax) =17,625.0 lbs
Max Point Load at opening (Pmax) =12,122.1 lbs
Continuous Reinforcing area of bar(in^2) =0.20 Min p =0.0018
Rebar Size =#4 fy = psi bar diameter(in) =0.50 Max p =0.0134
f'c = psi Total Bars =2 Use p =0.0018
B1 =0.85 As req(in^2)=0.2592
8 inches
Stemwall Height =36 Footing Thickness =8 inches
(2)#4
18 inches
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Cafe Calcs/[PAW Cont Foot - JURASSIC CAFE.xlsx]Footing 1
Footing Design
Stemwall Width =
inches
Continuous Rebar
Footing Width =
Stemwall Dimensions
18
8
Footing Rebar:
60000
2500
0 0
20 0
Footing and Stem Wall Dimensions:
Loading:
Dead Load (lbs) Live Load (lbs)
15 35
Soil Conditions:
Concrete Pad Footing
Strength Design per ACI 318-11
Mark: SonoTube:
inches
Material Data
P Self (k) =0.77 M DL (k-ft) =0.00 Allowable q (psf) =1500
P DL (k) =0.43 M LL (k-ft) =0.00 f'c (psi) =2500 B 1 =0.85
P LL (k) =1.11 Accidental Eccentricity =N Bars #3 and smaller, Fy (ksi) = 40
Pu (k) =3.2 Mu (k-ft) =0.00 Bars #4 and bigger, Fy (ksi) = 60
e (ft) = 0.00
within middle 3rd
Footing Dimensions: Column/Pier Base: Shear Check:
Long (ft) =1.33 Long Direction (in) =12 Punching Vc (psi) = 170
Short (ft) =1.33 Short Direction (in)=12 Wide Bm Vc (psi) = 85
Thickness (in) =36 Wide Bm Shear Cap. (lb/in) > Shear Force (lb/in)
% in center band B=100% 2784 >-389 OK
Punching Shear Resistance (k) > Applied Force (k)
Bearing Pressures:997 >-22 OK
q min (psf) =1308 q max (psf) =1308 OK
qu-max (psf) =1821 qu at edge of base (psf) =1821
qu-min (psf) =1821 qu at edge of base (psf) =1821
Reinforcing:
Reinforcement Top and Bottom(Y/N) =N
Base As(min) on calc'd As(4/3) (Y/N) =Y
Check Development Length
L' long (ft) = 0.16 Bar size =#4 p =0.0000 Fy (psi) = 60000
Mu (k-ft) = 0.02 area of bar = 0.20 Min p =0.0000 Ld1 (in) =24.0
d (in)= 32.75 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12
As req(in^2/ft)= 0.00 Spacing (in) = 10746 Use p =0.0000 Ld3 (in) =12
Total Bars = 1 Less than pmax, OK Available Ld (in) = 43.7 OK
Check Development Length
L' short (ft) = 0.16 Bar size =#4 p =0.0000 Fy (psi) = 60000
Mu (k-ft) = 0.01 area of bar = 0.20 Min p =0.0000 Ld1 (in) =24.0
d (in)= 32.25 bar diameter = 0.5 Max p =0.0134 Ld2 (in) =12
As req(in^2/ft)= 0.00 Spacing (in) = 21491 Use p =0.0000 Ld3 (in) =12
Total Bars = 1 Less than pmax, OK Available Ld (in) = 43.2 OK
P1 - Café Use:
w/ 1 #4
Short Direction Check p
P1 - Café 18
Loads: (U = 1.2DL + 1.6LL)
Long Direction Check p
1.3 feet long x 1.3 feet wide x 36'' thick Footing
Each Way
Project Jurassic Creek 0.00
Job No.Café 0.00
By 0.00 0.00
Date 11/29/23 0.00
Sheet _____ of ______
NBSD-Software.Com
DRIFTS ON ROOF PROJECTIONS AND PARAPETS
ASCE 7-10 CHAPTER 7 - SNOW LOADS
COMMERCIAL BUILDING - SAMPLE PROJECT, ANYTOWN
1. Snow Parameter Data
Building Parameters
L =30.00 feet (Length of Building)
W =20.00 feet (Width of Building)
Hp =3.00 feet (Height of parapet)
Snow Design Parameters Note: Tables and Figures provided courtesy of American Society of Civil Engineers (ASCE).
Occupancy:II (ASCE 7-10 Table 1.5-1)
Fully
Exposed
Partially
Exposed Sheltered
pg =50 B 0.9 1.0 1.2
C 0.9 1.0 1.1
EXP =B (Exposure Category, ASCE 7-10 Chapt 26.7)D 0.8 0.9 1.0
Above the treeline in widswept mountainous areas 0.7 0.8 N/A
Note:
House Structure
Kept at
Room Temp
Kept Above
Freezing Unheated
Greenhous
e with
Insulation
Thermal
Condition x
Note:
Fully
Exposed
Partially
Exposed Sheltered
Roof Condition x
2. Determination of Flat Roof Snow Load, Pf (Section 7.3)
Pf = 0.7 Cs Ct Is Pg (7.3-1)Where Ce =0.9 lb/ft2 (Exposure Factor, from Figure 7-2)
Ct =1.10 (Thermal Factor, Table 7-3)
I =1.00 (Importance factor, from ASCE 7-10 Table 1.5-2)
pg =50 lb/ft2 (Ground Snow Load, from Figure 7-1)
Pf =34.65 psf
3. Determination of Drift Loads (7.7)
a) Determination of Snow Density
γ = 0.13 Pg + 14 < 30 pcf (7.7-1)
Where pg =50 psf
γ = 20.50 pcf
b) Determination of Clear Height, hc
hc = Hp - hb Where Hp =3.00 feet (Height of parapet)
hb = pf / γ and pf =34.65 psf (Flat roof snow load)
γ = 20.50 pcf
hb = 1.69 feet (height of balanced snow load)
hc =1.31 feet
Chapter 26.7
N Above the treeline in widswept mountainous areas
(Y or N) ?
In Alaska, in areas where trees do not exist within a 2-
mile radius of the site
Table 7-2 Exposure Factor, Ce
Terrain Category
lb/ft2 (Ground Snow Load, from
Figure 7-1)
Chapter 26.7
Chapter 26.7
Slippery Non-Slippery
0.7 0.8 N/A
N In Alaska, in areas where trees do not exist within a
2-mile radius of the site (Y or N) ?
Roof Surface
x
Metal, Slate, glass,
bituminous, rubber,
plastic surfaces with a
smooth surface.
Membranes with
imbedded aggregate or
mineral granule surface,
asphalt shingles, wood
shingles, shakes.
p s f 2 0 Pf o r 2 0 g
Hp
Page 1 of 2 Snow Loads - Parapets - ASCE 7-10 Gravity Loads - JURASSIC CAFE 11/29/2023
Project Jurassic Creek 0.00
Job No.Café 0.00
By 0.00 0.00
Date 11/29/23 0.00
Sheet _____ of ______
NBSD-Software.Com
DRIFTS ON ROOF PROJECTIONS AND PARAPETS
ASCE 7-10 CHAPTER 7 - SNOW LOADS
COMMERCIAL BUILDING - SAMPLE PROJECT, ANYTOWN
1. Snow Parameter Data
Building Parameters
L =30.00 feet (Length of Building)
W =20.00 feet (Width of Building)
Hp =3.00 feet (Height of parapet)
Hp
d) Determine if Drift Loads are Required (7.7.1)
Note:If hc/hb < 0.2, drift loads are not required to be applied, where hc =1.31 feet
hb =1.69 feet
hc/hb =0.77
Drift loads must be considered!
a) Drift along Length of Building
4. Drift Loads on Roof Projections (Sect 7.7)
Pd = 34.11 psf Pf = 34.7 psf
a) Drift along Length of Building
1.66'
Lu = L =30 ft (Length of building)
pg =50 lb/ft2 (Ground Snow Load, from Figure 7-1)
0.75 hd =1.66 feet
w = 8.46'
Drift Width
Where hd =1.66 feet
hc =1.31 feet
<= Governs!
Thus, w =8.46 feet
hd =1.31 feet
Maximum Intensity of Drift Surcharge Load b) Drift along Width of Building
Pd = hd γ Where hd =1.66 feet Pd = 26.88 psf Pf = 34.7 psf
γ = 20.50 pcf
Pd =34.1 psf 1.31'
b) Drift along Width of Building
Lu = L =20 ft (Length of building)w = 5.25'
pg =50 lb/ft2 (Ground Snow Load, from Figure 7-1)
0.75 hd =1.31 feet
Drift Width
Where hd =1.31 feet
hc =1.31 feet
<= Governs!
Thus, w =5.25 feet
hd =1.31 feet
Maximum Intensity of Drift Surcharge Load
Pd = hd γ Where hd =1.31 feet
γ = 20.50 pcf
Pd =26.9 psf
(7.7.1) 1.5 - 10 p L 0.43 0.75 h 0.75 4 g3ud
dddcdh 4 wand h h ,h h If
h 8 h
h 4 wand h h ,h h If c
c
2
d
cdcd
(7.7.1) 1.5 - 10 p L 0.43 0.75 h 0.75 4 g3ud
dddcdh 4 wand h h ,h h If
h 8 h
h 4 wand h h ,h h If c
c
2
d
cdcd
Page 2 of 2 Snow Loads - Parapets - ASCE 7-10 Gravity Loads - JURASSIC CAFE 11/29/2023
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)312 @ 0 2813 (1.50")Passed (11%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)200 @ 7"2277 Passed (9%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)254 @ 1' 7 1/2"1696 Passed (15%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.005 @ 1' 7 1/2"0.108 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.007 @ 1' 7 1/2"0.162 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"85 227 312 None
2 - Trimmer - DF 1.50"1.50"1.50"85 227 312 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)3' 3" o/c
Bottom Edge (Lu)3' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 3' 3"N/A 4.2 --
1 - Uniform (PSF)0 to 3' 3"4'12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B1
2 piece(s) 2 x 6 DF No.2
ForteWEB Software Operator Job Notes 11/30/2023 12:07:41 AM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: CAFE
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)504 @ 0 2813 (1.50")Passed (18%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)392 @ 7"2277 Passed (17%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)662 @ 2' 7 1/2"1696 Passed (39%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.036 @ 2' 7 1/2"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.049 @ 2' 7 1/2"0.262 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 1.50"1.50"1.50"137 367 504 None
2 - Trimmer - DF 1.50"1.50"1.50"137 367 504 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 3" o/c
Bottom Edge (Lu)5' 3" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 5' 3"N/A 4.2 --
1 - Uniform (PSF)0 to 5' 3"4'12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B2
2 piece(s) 2 x 6 DF No.2
ForteWEB Software Operator Job Notes 11/30/2023 12:07:41 AM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: CAFE
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2458 @ 1 1/2"7875 (3.00")Passed (31%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1694 @ 10 1/4"5544 Passed (31%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)3079 @ 2' 9"8182 Passed (38%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.063 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.083 @ 2' 9"0.262 Passed (L/762)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 3.00"3.00"1.50"598 1860 2458 None
2 - Trimmer - DF 3.00"3.00"1.50"598 1860 2458 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 6" o/c
Bottom Edge (Lu)5' 6" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 5' 6"N/A 7.4 --
1 - Uniform (PSF)0 to 5' 6"17' 6"12.0 35.0 Default Load
2 - Uniform (PSF)0 to 5' 6"10'-6.4 DRIFT LOAD hd
gamma sqt S
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B3
2 piece(s) 1 3/4" x 7 1/4" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 11/30/2023 12:07:41 AM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: CAFE
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)2458 @ 1 1/2"7875 (3.00")Passed (31%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)1694 @ 10 1/4"5544 Passed (31%)1.15 1.0 D + 1.0 S (All Spans)
Moment (Ft-lbs)3079 @ 2' 9"8182 Passed (38%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.063 @ 2' 9"0.175 Passed (L/999+)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.083 @ 2' 9"0.262 Passed (L/762)--1.0 D + 1.0 S (All Spans)
System : Wall
Member Type : Header
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Trimmer - DF 3.00"3.00"1.50"598 1860 2458 None
2 - Trimmer - DF 3.00"3.00"1.50"598 1860 2458 None
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 6" o/c
Bottom Edge (Lu)5' 6" o/c
Dead Snow
Vertical Loads Location Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 5' 6"N/A 7.4 --
1 - Uniform (PSF)0 to 5' 6"17' 6"12.0 35.0 Default Load
2 - Uniform (PSF)0 to 5' 6"10'-6.4 DRIFT LOAD hd
gamma sqt S
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B4
2 piece(s) 1 3/4" x 7 1/4" 2.0E Microllam® LVL
ForteWEB Software Operator Job Notes 11/30/2023 12:07:41 AM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: CAFE
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)770 @ 2"7109 (3.50")Passed (11%)--1.0 D + 1.0 S (All Spans)
Shear (lbs)655 @ 9 1/2"3809 Passed (17%)1.15 1.0 D + 1.0 S (All Spans)
Pos Moment (Ft-lbs)1912 @ 5' 3 1/2"4313 Passed (44%)1.15 1.0 D + 1.0 S (All Spans)
Live Load Defl. (in)0.258 @ 5' 3 1/2"0.342 Passed (L/478)--1.0 D + 1.0 S (All Spans)
Total Load Defl. (in)0.357 @ 5' 3 1/2"0.512 Passed (L/344)--1.0 D + 1.0 S (All Spans)
System : Floor
Member Type : Drop Beam
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
•Deflection criteria: LL (L/360) and TL (L/240).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•Critical positive moment adjusted by a volume/size factor of 1.00 that was calculated using length L = 10' 3".
•The effects of positive or negative camber have not been accounted for when calculating deflection.
•The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Snow Factored Accessories
1 - Column - DF 3.50"3.50"1.50"215 556 770 Blocking
2 - Column - DF 3.50"3.50"1.50"215 556 770 Blocking
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)10' 7" o/c
Bottom Edge (Lu)10' 7" o/c
Dead Snow
Vertical Loads Location (Side)Tributary Width (0.90)(1.15)Comments
0 - Self Weight (PLF)0 to 10' 7"N/A 4.6 --
1 - Uniform (PSF)0 to 10' 7" (Front)3'12.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.
MEMBER REPORT PASSED
Level, B5
1 piece(s) 3 1/8" x 6" 24F-V4 DF Glulam
ForteWEB Software Operator Job Notes 11/30/2023 12:07:41 AM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: CAFE
Post Height: 9'
Design Results Actual Allowed Result LDF Load: Combination
Slenderness 31 50 Passed (62%)----
Compression (lbs)771 5727 Passed (13%)1.15 1.0 D + 1.0 S
Base Bearing (lbs)771 363825 Passed (0%)--1.0 D + 1.0 S
Bending/Compression 0.07 1 Passed (7%)1.15 1.0 D + 1.0 S
•Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
•Applicable calculations are based on NDS.
Supports Type Material
Base Plate Steel
Max Unbraced Length Comments
Full Member Length No bracing assumed.
Member Type : Free Standing Post
Building Code : IBC 2018
Design Methodology : ASD
Dead Snow
Vertical Load (0.90)(1.15)Comments
1 - Point (lb)215 556 Linked from: B5, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
Drawing is Conceptual
MEMBER REPORT PASSED
Level, P1
1 piece(s) 4 x 4 DF No.2
ForteWEB Software Operator Job Notes 11/30/2023 12:07:41 AM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: CAFE
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern)
Member Reaction (lbs)205 @ 5' 3 1/2"1406 (1.50")Passed (15%)--1.0 D + 0.7 E (All Spans)
Shear (lbs)170 @ 4' 10 5/16"1584 Passed (11%)1.60 1.0 D + 0.7 E (All Spans)
Moment (Ft-lbs)260 @ 2' 9"1357 Passed (19%)1.60 1.0 D + 0.7 E (All Spans)
Live Load Defl. (in)0.000 @ 0 0.268 Passed (2L/999+)--1.0 D (All Spans)
Total Load Defl. (in)0.016 @ 2' 9"0.357 Passed (L/999+)--1.0 D (All Spans)
System : Roof
Member Type : Joist
Building Use : Residential
Building Code : IBC 2018
Design Methodology : ASD
Member Pitch : 4/12
•Deflection criteria: LL (L/240) and TL (L/180).
•Allowed moment does not reflect the adjustment for the beam stability factor.
•A 15% increase in the moment capacity has been added to account for repetitive member usage.
•Applicable calculations are based on NDS.
• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed.
• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger
• ¹ See Connector grid below for additional information and/or requirements.
Bearing Length Loads to Supports (lbs)
Supports Total Available Required Dead Seismic Factored Accessories
1 - Beveled Plate - DF 3.50"3.50"1.50"87 193/-193 222/-83 Blocking
2 - Hanger on 5 1/2" DF Ledger 3.50"Hanger¹1.50"89 198/-198 228/-85 See note ¹
•Maximum allowable bracing intervals based on applied load.
Lateral Bracing Bracing Intervals Comments
Top Edge (Lu)5' 7" o/c
Bottom Edge (Lu)5' 7" o/c
Connector: Simpson Strong-Tie
Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories
2 - Face Mount Hanger Connector not found N/A N/A N/A N/A
•Refer to manufacturer notes and instructions for proper installation and use of all connectors.
Dead Seismic
Vertical Load Location (Side)Spacing (0.90)(1.60)Comments
1 - Uniform (PSF)0 to 5' 7"24"15.0 35.0 Default Load
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.Member Length : 5' 8 3/4"
MEMBER REPORT PASSED
Level, J1
1 piece(s) 2 x 6 DF No.2 @ 24" OC
ForteWEB Software Operator Job Notes 11/30/2023 12:07:41 AM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: CAFE
Post Height: 9'
Design Results Actual Allowed Result LDF Load: Combination
Slenderness 31 50 Passed (62%)----
Compression (lbs)1542 5727 Passed (27%)1.15 1.0 D + 1.0 S
Base Bearing (lbs)1542 363825 Passed (0%)--1.0 D + 1.0 S
Bending/Compression 0.19 1 Passed (19%)1.15 1.0 D + 1.0 S
•Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
•Applicable calculations are based on NDS.
Supports Type Material
Base Plate Steel
Max Unbraced Length Comments
Full Member Length No bracing assumed.
Member Type : Free Standing Post
Building Code : IBC 2018
Design Methodology : ASD
Dead Snow
Vertical Loads (0.90)(1.15)Comments
1 - Point (lb)215 556 Linked from: B5, Support 1
2 - Point (lb)215 556 Linked from: B5, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
Drawing is Conceptual
MEMBER REPORT PASSED
Level, P2
1 piece(s) 4 x 4 DF No.2
ForteWEB Software Operator Job Notes 11/30/2023 12:07:41 AM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: CAFE
Post Height: 9'
Design Results Actual Allowed Result LDF Load: Combination
Slenderness 31 50 Passed (62%)----
Compression (lbs)771 5727 Passed (13%)1.15 1.0 D + 1.0 S
Base Bearing (lbs)771 363825 Passed (0%)--1.0 D + 1.0 S
Bending/Compression 0.07 1 Passed (7%)1.15 1.0 D + 1.0 S
•Input axial load eccentricity for this design is 16.67% of applicable member side dimension.
•Applicable calculations are based on NDS.
Supports Type Material
Base Plate Steel
Max Unbraced Length Comments
Full Member Length No bracing assumed.
Member Type : Free Standing Post
Building Code : IBC 2018
Design Methodology : ASD
Dead Snow
Vertical Load (0.90)(1.15)Comments
1 - Point (lb)215 556 Linked from: B5, Support 1
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties
related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is
responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at
Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387
and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to
www.weyerhaeuser.com/woodproducts/document-library.
The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator
Weyerhaeuser Notes
Drawing is Conceptual
MEMBER REPORT PASSED
Level, P3
1 piece(s) 4 x 4 DF No.2
ForteWEB Software Operator Job Notes 11/30/2023 12:07:41 AM UTC
Eric Stoddard
Civilize PLLC
(208) 206-6653
ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1
File Name: CAFE
Location:
Height (ft) =10.0 Gravity Loads to Wall:
Le/d = 21.8 < 50 OK DL(psf) trib(ft) w e(in)
deflection < L/240 roof snow 12 17 799 0
wind/seismic (W/S)W floor live load 0 0 0 0
wind load, w (psf) =30 (Due to Wind)wall weight 15 15 225
0.6 * w = (psf) 18.0 misc. live load 0 0 0 0
snow load? (Y/N)Y w (total uniform load) = 1024 plf
Lumber Grade: (DF No. 2)
Load Cases:
CD =1.60 CD =1.60 CD =1.15
P (lbs) = 572 per stud P (lbs) = 595 P (lbs) = 1365 per stud
M (lb-ft) = 300 M (lb-ft) = 225 M (lb-ft) = 0
FcE (psi) =1002 FcE (psi) =1002 FcE (psi) =1002
Fc' (psi) = 894 Fc' (psi) = 894 Fc' (psi) = 839
fc (psi) = 69 < Fc'OK fc (psi) = 72 < Fc'OK fc (psi) = 165 < Fc'OK
Fb' (psi) = 2153 Fb' (psi) = 2153 Fb' (psi) = 1547
fb (psi) = 476 < Fb'OK fb (psi) = 357 < Fb'OK fb (psi) = 0 < Fb'OK
CSR = 0.24 < 1.0 OK CSR = 0.19 < 1.0 OK CSR = 0.04 < 1.0 OK
D (in.) =0.11 = L/1056 OK D (in.) =0.09 = L/1408 OK D (in.) =0.00 = L/5000 OK
USE:2 x 6
Framing at Openings:
Trimmers: King Studs:
Trimmer supports only vertical load ... King stud supports only bending ...
Pcap (lbs) = 6924 Mcap (lb-ft) = 1180
Rcap (lbs) = 5156
(bearing governs)trib width capacity (ft) = 5.24 for M < Mcap
(governs)
trib width capacity (ft) = 5.87 for D < L /240
(DF No. 2)Typical 10'-0" Plate
1
319'-7'' to 30'-1''
1
1
1
1
29'-1'' to 19'-7''
< 9'-1''
30'-1'' to 40'-7'' 5
3
1
1
4
2
1
11
1
Wood Stud Wall Design
Design based on NDS 2012
Trimmer Studs (TS) King Studs (KS)
at 16'' o.c.
D + S
Open Width (ft)
Typical 10'-0" Plate
0
LL(psf)
D + 0.6*W D + 0.75*(0.6*W + S + LL)
35
0
Cy Hepworth Structural Calculations Package
Jurassic Creek Project No. 02-23-006
Civilize, PLLC | P a g e
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Calcs Package-
Hepworth.docx
JURASSIC CREEK
CAFE
LATERAL DESIGN
Project JURASSIC CREEK
Job No.CAFÉ
By EAS
Date 11/29/23
Sheet _____ of ______
NBSD-Software.Com
MAIN WIND FORCE RESISTING SYSTEMS - WALLS AND ROOF
ASCE 7-10 WIND PROVISIONS - CHAPTER 28 - ENVELOPE PROCEDURE PART 2 - ENCLOSED SIMPLE DIAPHRAGM LOW-RISE BUILDINGS
ENCLOSED COMMERCIAL BUILDING - SAMPLE PROJECT, ANYTOWN
Requirements :- Building has Simple Diaphragms per Section 26.2
ASCE 7-10 Figure 28.6-1
1. Building Parameters Please note:
Risk Category:II (ASCE 7-10 Table 1.5-1) ASCE 7-10 Figure 28.6-1 data and information provided for reference courtesy of
Site Data American Society of Civil Engineers (ASCE) and Structural Engineering Institute (SEI).
EXP =C (Exposure Category per ASCE 26.7.3)
V =90 mph (Basic Wind Speed, ASCE 7-10 Fig 26.5-1A)
Building Dimensions
Vertical:Horizontal:
H1 = 15.00 feet m = 10.00 feet Roof Angle θ = 0.00 degrees (Windward Side)
H2 = 0.00 feet n = 10.00 feet = 11.31 degrees (Leeward Side)
H3 = 13.00 feet
H4 = 2.00 feet Mean Roof Height (ASCE 7-10 Section 26.2):
W = 20.00 feet (Transverse building dimension)
Hmr = AVERAGE (He,Hmax), for θ >10 degrees, otherwise He
L = 30.00 feet (Longitudinal building dimension)
Where Hmax =15.00 ft (maximum elevation)
Heave =15.00 ft (Max Eave Height)
Hmr =15.00 ft (Mean Roof Height)
2. Wind Velocity Pressure (ASCE 7-10 28.6.3)
ps = λ Kzt Ps30 (EQ 28.6-1)
Where λ =1.21 (Adjustment Factor for Building Height and Exposure, per Fig 6-2, Exp C, H = 15 feet)
Kzt =1.00 (Topographic Factor per Figure 6-4 - No info provided on topography)
ps =1.21 * ps30 psf (Wind Velocity Pressure)
3. Wind Pressure Values from ASCE 7-10 Figure 28.6-1, at Basic Wind Speed
a) Wind Pressures ps30 on MWFRS
For θ =11.31 degrees (Windward Side)
A B C D E F G H EOH GOH
90 0 to 5°1 19.2 -10.0 12.7 -5.9 -23.1 -13.1 -16.0 -10.1 -32.3 -25.3
10 1 21.6 -9.0 14.4 -5.2 -23.1 -14.1 -16.0 -10.8 -32.3 -25.3
15 1 24.1 -8.0 16.0 -4.6 -23.1 -15.1 -16.0 -11.5 -32.3 -25.3
20 1 26.6 -7.0 17.7 -3.9 -23.1 -16.0 -16.0 -12.2 -32.3 -25.3
25 1 24.1 3.9 17.4 4.0 -10.7 -14.6 -7.7 -11.7 -19.9 -17.0
2 -----4.1 -7.9 -1.1 -5.1 --
30 to 45° 1 21.6 14.8 17.2 11.8 1.7 -13.1 0.6 -11.3 -7.6 -8.7
2 21.6 14.8 17.2 11.8 8.3 -6.5 7.2 -4.6 -7.6 -8.7
1 22.25 -8.74 14.82 -5.04 -23.10 -14.36 -16.00 -10.98 -32.30 -25.30
2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
- building must be regular shaped low-rise building
as defined in Section 26.2
11.31
- Building is not sited at a location where
channeling effects or buffeting in the wake of
upwind obstructions need to be considered.
Simplified Design Wind Pressure, Ps30 (psf) (Exposure B at h = 30 ft., Kzt =1.0)
Basic Wind
Speed (mph)
Roof Angle
(degrees)Load Case
- Building does not have complex response
characteristics (vortex chedding, etc);
Zones
Horizontal Pressures Vertical Pressures Overhangs
H1
H2
H3
H4
m n
W
MWFRS Wind Pressures Page 1 of 2 ASCE 7-10 MWFRS - Envel Proced Part 2 - JURASSIC CAFE 11/29/2023
Project JURASSIC CREEK
Job No.CAFÉ
By EAS
Date 11/29/23
Sheet _____ of ______
NBSD-Software.Com
MAIN WIND FORCE RESISTING SYSTEMS - WALLS AND ROOF
ASCE 7-10 WIND PROVISIONS - CHAPTER 28 - ENVELOPE PROCEDURE PART 2 - ENCLOSED SIMPLE DIAPHRAGM LOW-RISE BUILDINGS
ENCLOSED COMMERCIAL BUILDING - SAMPLE PROJECT, ANYTOWN
Requirements :- Building has Simple Diaphragms per Section 26.2
ASCE 7-10 Figure 28.6-1
- building must be regular shaped low-rise building
as defined in Section 26.2
- Building is not sited at a location where
channeling effects or buffeting in the wake of
upwind obstructions need to be considered.
- Building does not have complex response
characteristics (vortex chedding, etc);
H1
H2
H3
H4
m n
W
3. Wind Pressure Values from ASCE 7-10 Figure 28.6-1, at Basic Wind Speed (Cont)
b) Wind Pressures ps on MWFRS
A B* C D* E F G H EOH GOH
1 26.93 -10.57 17.93 -6.10 -27.95 -17.38 -19.36 -13.29 -39.08 -30.61
2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
A B* C D* E F G H
EOH GOH
ps (Psf)1 23.23 -12.10 15.37 -7.14 -27.95 -15.85 -19.36 -12.22 -39.08 -30.61
Notes:1. For Longitudinal MWFRS, use θ = 0°, and locate Zone E/F and G/H boundary at mid length of building.
2. Horizontal and Vertical pressures shown represent the sum of internal and external pressures.
3*. Per Note 7, the total horizontal load must not be less than that determined by assuming p s = 0 in Zones B and D.
4. The minimum wind load case of 28.6.4 must also be considered, as follows:
A B*C D*E F G H
ps (Psf)16.00 8.00 16.00 8.00 0.00 0.00 0.00 0.00
Extent of Loading:
a = MAX { MIN (10% Least Dimension, 40% Eave Height), 4% Least Dimension or 3.0'}Where 10% Least Dimension = 2.00 feet
40% Eave Height = 0.40 Hmr =6.00 feet
Therefore a = 3.00 feet (See note 9 in Figure 28.6-1) 4% Least Dimension, or 3 ft = 3.00 feet
2a = 6.00 feet
Horizontal Pressures Vertical Pressures
Load Case Horizontal Pressures Vertical Pressures
Horizontal Pressures Vertical PressuresLoad Case
Overhangs
Transverse Loading (Case A)
Longitudinal Loading (Case B)
Overhangs
ps (Psf)
MWFRS Wind Pressures Page 2 of 2 ASCE 7-10 MWFRS - Envel Proced Part 2 - JURASSIC CAFE 11/29/2023
Project Analysis Worksheet
Structural Calculations
Lateral Distribution
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Café CHECKED EAS
Project No.:02-23-006 DATE: 11/22/2023
Project Location
Risk Category per ASCE 7 =II Exposure =C Site Class =D
Wind Speed =90 Importance Factor Iw =1.00 Roof DL =15 psf
Bldg/Area Length, L =30 ft Overall Structure Height =15.0 ft Ground Snow Load (Pg) =50 psf
Bldg/Area Width, W =20 ft Plate Height = 10.0 ft Percent Seismic (Pg) =20%
Edge Strip (a)=3 ft Wall Weight = 20.0 psf Ss =36.9%g
End Zone (2a)=6 ft R = 6.5 S1 =14.1%g
Roof Type (receiving wind) = Roof Type (receiving wind) =Gable End
Use Only End Zone Pressures = Use Only End Zone Pressures =N
Interior Pressure (psf) (T-H-C)= Interior Pressure (psf) (L-H-C) =15.4
Roof Interior Pressure (psf) (T-H-D)= Roof Interior Pressure (psf) =-6.1
End Zone Pressure (psf) (T-H-A) = End Zone Pressure (psf) (L-H-A)=23.2
Roof End Zone Pressure (psf) (T-H-B)= Roof End Zone Pressure (psf) =-10.6
Wind Lateral Load Vertical Distribution:
Transverse Force
Level hi (ft) di (ft) wx-end zone (plf) wx-min (plf) wx-avg (plf) Fx (kip)
1st 10 5 269 160 215 LRFD 6.5
Longitudinal Force
Level hi (ft) di (ft) wx-end zone (plf) wx-min (plf) wx-avg (plf) Fx (kip)
1st 10 5 232 160 185 LRFD 3.7
Seismic Lateral Loading:ASCE 7-16
SMS = 0.555g CS = 0.057 T = 0.133 T0 = 0.118
SDS = 0.370g Cs-max = 0.252 Ta = 0.133 TS = 0.589
SM1 = 0.33g Cs-min = 0.016 Tmax = 0.186 Sa = 0.370
SD1 = 0.218g CS (controls)= 0.057 CU = 1.4 k = 1.00
TL =6 Fv = 2.32 Roof Area = 704
Ct =0.020 Fa = 1.50 Seismic Weight = 27.6
x =0.750 V = 1.6
Seismic Lateral Distribution:
Level hx (ft) wx (kip)wx hx
k (kip-ft)Cvx Fx (kip) Vx (kip)
1st 12.5 27.6 345 1.000 1.6 LRFD 1.6
Total Lateral Distribution: ASD
Wind = 2222
Seismic = 1100
Wind = Seismic =
3875 1100
pounds pounds
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Cafe Calcs/[PAW_Lateral Distribution - JURASSIC CAFE.xlsx]Lateral Distribution
-10.6
Lateral Loading:
Wind Lateral Pressures:
Longitudinal Direction (parallel to L):Transverse Direction (normal to L):
Gable End
N
17.9
-6.1
pounds 20 ft.
30 ft.
154
wx-interior (plf)
pounds
wx-interior (plf)
179
26.9
Project Analysis Worksheet
Structural Calculations
Shear Wall
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Café CHECKED EAS
Project No.:02-23-006 DATE: 11/28/2023
Project Location
Line = ASD Seismic =550 lbs
ASD Wind =1111 lbs
Roof DL =15 psf
Wall DL = 15 psf
Sds =0.37 g
Seismic:
Wall Segment = 4
Height (ft) = total:
Length (ft) = 30
Roof Trib (psf) =
aspect ratio
aspect ratio factor total:
Effective Length 30
Seismic:
F =
shear =
Moment =
DL factor 1 =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wind:
F =
shear =
Moment =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wall Results:
Wall Length = ft ft ft ft
Max Seismic Shear = plf plf plf plf
Max Wind Shear = plf plf plf plf
Max Compression Seismic= lbs lbs lbs lbs
Max Compression Wind= lbs lbs lbs lbs
Max Uplift Seismic = lbs lbs lbs lbs
Max Uplift Wind = lbs lbs lbs lbs
Shear wall Type :D
APA Rated Sheating (in.): 7/16
Blocking: Unblocked
Edge Nailing (8d O.C.): 6 in.
Field Nailing (8d O.C.): 6 in.
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Cafe Calcs/[PAW_Shear Wall - JURASSIC CAFE.xlsx]A.1
12
30
A.1
1 2 3
1
30
4
0.4
6600.0
1.0518
550.0
18.3
0.5482
131.568
252.432
998.1
37.0
13332.0
0.0
1111.0
0.60
144
240
1170.9
18.3
OK
0.0
30
1170.9
998.1
37.0
OK
B D D
0.0
0.0
6 in. 6 in. 6 in.
12 in. 6 in. 6 in.
7/16 7/16 7/16
Unblocked Unblocked Unblocked
Project Analysis Worksheet
Structural Calculations
Shear Wall
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Café CHECKED EAS
Project No.:02-23-006 DATE: 11/28/2023
Project Location
Line = ASD Seismic =550 lbs
ASD Wind =1111 lbs
Roof DL =15 psf
Wall DL = 15 psf
Sds =0.37 g
Seismic:
Wall Segment = 4
Height (ft) = total:
Length (ft) = 17.75
Roof Trib (psf) =
aspect ratio
aspect ratio factor total:
Effective Length 16.91666667
Seismic:
F =
shear =
Moment =
DL factor 1 =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wind:
F =
shear =
Moment =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wall Results:
Wall Length = ft ft ft ft
Max Seismic Shear = plf plf plf plf
Max Wind Shear = plf plf plf plf
Max Compression Seismic= lbs lbs lbs lbs
Max Compression Wind= lbs lbs lbs lbs
Max Uplift Seismic = lbs lbs lbs lbs
Max Uplift Wind = lbs lbs lbs lbs
Shear wall Type :F
APA Rated Sheating (in.): 7/16
Blocking: Blocked
Edge Nailing (8d O.C.): 4 in.
Field Nailing (8d O.C.): 12 in.
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Cafe Calcs/[PAW_Shear Wall - JURASSIC CAFE.xlsx]A.2
12 12
12.75 5
A.1
1 2 3
1 0.83333333
12.75 4.16666667
4 4
0.9 2.4
4974.4 1625.6
1.0518 1.0518
414.5 135.5
32.5 27.1
0.5482 0.5482
131.568 131.568
252.432 252.432
1206.6 1092.8
65.7 54.7
10048.3 3283.7
0.0 non req
837.4 273.6
0.60 0.60
144 144
240 240
1528.1 1300.1
32.5 27.1
OK OK
0.0 non req
12.75 5
1528.1 1300.1
1206.6 1092.8
65.7 54.7
OK OK
B B F
0.0 non req
0.0 non req
6 in. 6 in. 4 in.
12 in. 12 in. 12 in.
7/16 7/16 7/16
Unblocked Unblocked Blocked
Project Analysis Worksheet
Structural Calculations
Shear Wall
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Café CHECKED EAS
Project No.:02-23-006 DATE: 11/28/2023
Project Location
Line = ASD Seismic =550 lbs
ASD Wind =1937.5 lbs
Roof DL =15 psf
Wall DL = 15 psf
Sds =0.37 g
Seismic:
Wall Segment = 4
Height (ft) = total:
Length (ft) = 20
Roof Trib (psf) =
aspect ratio
aspect ratio factor total:
Effective Length 20
Seismic:
F =
shear =
Moment =
DL factor 1 =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wind:
F =
shear =
Moment =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wall Results:
Wall Length = ft ft ft ft
Max Seismic Shear = plf plf plf plf
Max Wind Shear = plf plf plf plf
Max Compression Seismic= lbs lbs lbs lbs
Max Compression Wind= lbs lbs lbs lbs
Max Uplift Seismic = lbs lbs lbs lbs
Max Uplift Wind = lbs lbs lbs lbs
Shear wall Type :D
APA Rated Sheating (in.): 7/16
Blocking: Unblocked
Edge Nailing (8d O.C.): 6 in.
Field Nailing (8d O.C.): 6 in.
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Cafe Calcs/[PAW_Shear Wall - JURASSIC CAFE.xlsx]B.1
6 in. 6 in. 6 in.
12 in. 6 in. 6 in.
7/16 7/16 7/16
Unblocked Unblocked Unblocked
B D D
0.0
0.0
2397.5
1659.8
96.9
OK
27.5
OK
0.0
20
0.60
243
405
2397.5
96.9
23250.0
0.0
1937.5
0.5482
222.021
425.979
1659.8
6600.0
1.0518
550.0
27.5
1
20
15
0.6
12
20
B.1
1 2 3
Project Analysis Worksheet
Structural Calculations
Shear Wall
Client:Cy Hepworth DESIGNED EAS
Project:Jurassic Creek - Café CHECKED EAS
Project No.:02-23-006 DATE: 11/28/2023
Project Location
Line = ASD Seismic =550 lbs
ASD Wind =1937.5 lbs
Roof DL =15 psf
Wall DL = 15 psf
Sds =0.37 g
Seismic:
Wall Segment = 4
Height (ft) = total:
Length (ft) = 10
Roof Trib (psf) =
aspect ratio
aspect ratio factor total:
Effective Length 6.8
Seismic:
F =
shear =
Moment =
DL factor 1 =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wind:
F =
shear =
Moment =
wDL =
Compression =
DL factor 2 =
wDL =
Uplift =
Wall Results:
Wall Length = ft ft ft ft
Max Seismic Shear = plf plf plf plf
Max Wind Shear = plf plf plf plf
Max Compression Seismic= lbs lbs lbs lbs
Max Compression Wind= lbs lbs lbs lbs
Max Uplift Seismic = lbs lbs lbs lbs
Max Uplift Wind = lbs lbs lbs lbs
Shear wall Type :B
APA Rated Sheating (in.): 7/16
Blocking: Unblocked
Edge Nailing (8d O.C.): 6 in.
Field Nailing (8d O.C.): 12 in.
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Cafe Calcs/[PAW_Shear Wall - JURASSIC CAFE.xlsx]B.2
10 10 10
3 4 3
B.2
1 2 3
0.6 0.8 0.6
1.8 3.2 1.8
17 17 17
3.3 2.5 3.3
1455.9 2588.2 1455.9
1.0518 1.0518 1.0518
145.6 258.8 145.6
48.5 64.7 48.5
0.5482 0.5482 0.5482
222.021 222.021 222.021
425.979 425.979 425.979
1420.1 1776.6 1420.1
171.0 227.9 171.0
5128.7 9117.6 5128.7
non req non req non req
512.9 911.8 512.9
0.60 0.60 0.60
243 243 243
405 405 405
2453.4 3223.7 2453.4
48.5 64.7 48.5
OK OK OK
1737.4 2161.5 1737.4
3 4 3
2453.4 3223.7 2453.4
1420.1 1776.6 1420.1
171.0 227.9 171.0
OK OK OK
E E E
non req non req non req
1737.4 2161.5 1737.4
6 in. 6 in. 6 in.
12 in. 12 in. 12 in.
7/16 7/16 7/16
Blocked Blocked Blocked
Cy Hepworth Structural Calculations Package
Jurassic Creek Project No. 02-23-006
Civilize, PLLC 1 | P a g e
https://civilize-my.sharepoint.com/personal/estoddard_civilize_design/Documents/Frost Reference/Civilize Marketing/Hepworth/Calcs Package-
Hepworth.docx
Exhibit C
Design Drawings