Loading...
HomeMy WebLinkAboutSTRUCTURAL SUPPLEMENTAL INFO - 23-00089 - Manufab - New Commercial ShopFROST Structural Engineering 1020 Lincoln Road Phone: 208.227.8404 Idaho Falls, ID 83401 Fax: 208.227.8405 www.frost-structural.com SSI No. : Re : Project : Date:SEAL: To : From : Project No. : Reference:Instruction: FSE December 12, 2024 Add the H2.5a clips noted in the plan notes section of S2.4 and on details 321 and 324S2.4, S5.2 The splices in the walls as observed on site are okay as is with the beam framed aboveS2.4 STRUCTURAL SUPPLEMENTAL INFORMATION 3 Sandblasting cabinet framing Manufab Building Justin Rasmussen Cody Brian IF22-187 S2.3 See the attached marked up screenshot of page S2.3 S2.4 See the attached marked up screenshot of page S2.4 S5.2 See the attached marked up detail 324 12/12/2024 FROST Structural Engineering FSE 1 A 21'-65 8" 9' - 4 " 9' - 4 " SC1 SC1 SC1 WF18 / W3 WF 1 8 / W 3 110 110 110 111 111 112 5 6. SIMPSON HTT4 SIMPSON HTT4 PLACE HOLDOWN AT END OF WOOD STUD WALL NEXT TO DOOR. PROVIDE DOUBLE STUD TO ATTACH HOLDOWN TO DRILL AND EPOXY ANCHOR FOR HOLDOWN INTO EXISTING CONCRETE W/ SIMPSON SET 3G EPOXY AND 16" MINIMIM EMBEDMENT SNAPSHOT OF SANDBLASTING CABINET FOUNDATION FROST Structural Engineering FSE SNAPSHOT OF SANDBLASTING CABINET FRAMING A SC1 W14x26 W1 4 x 2 6 W1 4 x 2 6 SC1 323 322 2TYP 5 326 6. 326 SHEATHING INSIDE FACE OF WALL FROM BOTTOM TO UNDERSIDE OF BEAM W/ #5 TYP SHEARWALL IN ADDITION TO THE SHEATHING PROVIDED ON THE OUTSIDE 5 FROST Structural Engineering FSE 324 WOOD TRUSS AT WOOD BEAM NO SCALE 1 KEYNOTES: 1.WOOD TRUSS W/ CLIP, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ 14"Øx412" LONG SDS SCREW AT 12" O.C. INTO NAILER 3.EXISTING ICF CONCRETE WALL, SEE PLAN 4.ROOF SHEATHING, SEE PLAN 5.BOUNDARY NAILING, SEE PLAN 6.FULL-HEIGHT TRUSS BLOCKING BETWEEN EACH TRUSS W/ A35 CLIP 7.CONT 2x NAILER W/ 5 8"Ø THREADED STUD AT 24" O.C. 8.WOOD STUD WALL, SEE PLAN 9.STEEL BEAM, SEE PLAN NOTES: A.COORDINATE ROOF VENTILATION B.FASCIA PER ARCHITECTURAL DETAILS 3 4 5 6 2 8 7 7 9 CONT 2x W/ 1/2"øx8" LONG TITEN HD ANCHOR AT 24" O.C. INTO ICF BLOCK WALL