HomeMy WebLinkAboutSITE OBSERVATION REPORT - 23-00089 - Manufab - New Commercial ShopFROST Structural Engineering
1020 Lincoln Road Phone: 208.227.8404
Idaho Falls, ID 83401 Fax: 208.227.8405
www.frost-structural.com
Report No. :
Project :
Visit Date:
Report Date:
To :
By :
Reference:Observation:
FSE
Note: Many of the items noted here-in may not have been completed at the time of observation
due to phase of construction. These items are solely observations made and do not supersede
the intent of the original construction documents, unless specifically noted above.
Two areas of floor framing were observered over the restrooms in the
main shop area that cantilever out past the edge of the wall. Please
see the construction set labeled Rev 3 for for the framing requirements
that must be met for this floor framing system. All foundations are
acceptable for this, assuming the slab was poured as noted on the
plans.
S2.1
It was observed that no protective coatings were applied to the steel on
the exterior of the building that is exposed to the elements. It is the
contractor's responsibility to ensure a protective coating is applied to all
exposed exterior steel that is suitable to protect the steel against the
elements. This coating can be clear if desired.
S2.1, S2.2
The exterior steel trellis framing on the front of the building is not anticipated to be
built until a later date. It is recommended that all steel that has been installed for this
roof be sufficiently protected from corrosion until the structure is installed per the
construction documents and then appropriately finished afterwards as noted above
S2.1
All other elements that were observed and visible during the time of visit appears to
be installed per the construction documents, see the attached photos.
Justin Rasmussen
Cody Brian
SITE OBSERVATION REPORT
1 (Site Visit)
Manufab Building
March 11, 2025
March 20, 2025
FROST Structural Engineering
FSE
Photo #1 - Exterior view of northeast corner of building (Structural beam tails and corner support)
FROST Structural Engineering
FSE
Photo #2 - Exterior view of northeast corner of front office(Structural beams with large cantilever)
FROST Structural Engineering
FSE
Photo #3 - Exterior view of northwest corner of sandblasting cabinet (no structural elements visible)
FROST Structural Engineering
FSE
Photo #4 - Exterior view of west wall of shop (Structural beam tails)
FROST Structural Engineering
FSE
Photo #5 - Exterior view of southeast corner of building (Structural beam tails)
FROST Structural Engineering
FSE
Photo #6 - Interior view of east wall of shop (Angle kickers, cable bracing, exposed structural beam visible)
FROST Structural Engineering
FSE
Photo #7 - Interior view of ceiling in east wing of shop (Cable bracing, exposed structural beams visible)
FROST Structural Engineering
FSE
Photo #8 - Interior view of office space with cantilevered floor framing (Cable bracing, exposed structural beams visible)
FROST Structural Engineering
FSE
Photo #9 - Interior view of ceiling of east wing of shop (Angle kickers, cable bracing, exposed structural beams visible)
FROST Structural Engineering
FSE
Photo #10 - Interior view of southeast corner of building (Cable bracing, exposed structural beams, steel column between beams visible)
FROST Structural Engineering
FSE
Photo #11 - Interior view of south wall of building (Steel angle kickers, cable bracing, exposed structural beams visible)
FROST Structural Engineering
FSE
Photo #12 - Interior view of ceiling in office on second floor (Exposed structural beam visible)
FROST Structural Engineering
FSE
Photo #13 - Interior view of ceiling in office on main floor (Exposed structural beam visible)