Loading...
HomeMy WebLinkAboutSITE OBSERVATION REPORT - 23-00089 - Manufab - New Commercial ShopFROST Structural Engineering 1020 Lincoln Road Phone: 208.227.8404 Idaho Falls, ID 83401 Fax: 208.227.8405 www.frost-structural.com Report No. : Project : Visit Date: Report Date: To : By : Reference:Observation: FSE Note: Many of the items noted here-in may not have been completed at the time of observation due to phase of construction. These items are solely observations made and do not supersede the intent of the original construction documents, unless specifically noted above. Two areas of floor framing were observered over the restrooms in the main shop area that cantilever out past the edge of the wall. Please see the construction set labeled Rev 3 for for the framing requirements that must be met for this floor framing system. All foundations are acceptable for this, assuming the slab was poured as noted on the plans. S2.1 It was observed that no protective coatings were applied to the steel on the exterior of the building that is exposed to the elements. It is the contractor's responsibility to ensure a protective coating is applied to all exposed exterior steel that is suitable to protect the steel against the elements. This coating can be clear if desired. S2.1, S2.2 The exterior steel trellis framing on the front of the building is not anticipated to be built until a later date. It is recommended that all steel that has been installed for this roof be sufficiently protected from corrosion until the structure is installed per the construction documents and then appropriately finished afterwards as noted above S2.1 All other elements that were observed and visible during the time of visit appears to be installed per the construction documents, see the attached photos. Justin Rasmussen Cody Brian SITE OBSERVATION REPORT 1 (Site Visit) Manufab Building March 11, 2025 March 20, 2025 FROST Structural Engineering FSE Photo #1 - Exterior view of northeast corner of building (Structural beam tails and corner support) FROST Structural Engineering FSE Photo #2 - Exterior view of northeast corner of front office(Structural beams with large cantilever) FROST Structural Engineering FSE Photo #3 - Exterior view of northwest corner of sandblasting cabinet (no structural elements visible) FROST Structural Engineering FSE Photo #4 - Exterior view of west wall of shop (Structural beam tails) FROST Structural Engineering FSE Photo #5 - Exterior view of southeast corner of building (Structural beam tails) FROST Structural Engineering FSE Photo #6 - Interior view of east wall of shop (Angle kickers, cable bracing, exposed structural beam visible) FROST Structural Engineering FSE Photo #7 - Interior view of ceiling in east wing of shop (Cable bracing, exposed structural beams visible) FROST Structural Engineering FSE Photo #8 - Interior view of office space with cantilevered floor framing (Cable bracing, exposed structural beams visible) FROST Structural Engineering FSE Photo #9 - Interior view of ceiling of east wing of shop (Angle kickers, cable bracing, exposed structural beams visible) FROST Structural Engineering FSE Photo #10 - Interior view of southeast corner of building (Cable bracing, exposed structural beams, steel column between beams visible) FROST Structural Engineering FSE Photo #11 - Interior view of south wall of building (Steel angle kickers, cable bracing, exposed structural beams visible) FROST Structural Engineering FSE Photo #12 - Interior view of ceiling in office on second floor (Exposed structural beam visible) FROST Structural Engineering FSE Photo #13 - Interior view of ceiling in office on main floor (Exposed structural beam visible)