HomeMy WebLinkAboutSEPTIC PERMIT - 23-00089 - Manufab - New Commercial ShopPERMIT-Subsurface Sewage Disposal
EASTERN IDAHO PUBLIC HEALTH
'1250 HOLLIPARK DRIVE permir#:
IDAHO FALLS lD 83401 Dare:
(208) 523-5382 Parcet #:
3324047
06111 t2024
Public flealttr
Idaho tublic Health Dishicts
Justin Rasmussen
RP05TS80020020
Justin Rasmussen
2959 Grizzly Lane Rexburg lD 83440
Township 5N Range 39E Section 23
Subdivision: TEXAS SIDING BUSINESS PARK Lot 2 Block 2 Size(ecres): 4.74
T),pe oflnstallation Type ofSystem (check all that apply)Water Supply
C Tank Only
E New System
E Expansion
tr Repair
E ISAS Repair
D LSAS New
E Absorption Bed
tr Capping Fill
E Central System
tr Composting Toilet
E Drip Distribution
f] ETPS
E Experimental
D Extra Drainrock
E Evapotranspiration
E Gravcl Drainfield
E Gravelless Drainfield
E Gray Water Sump
E GIay Water System
tr Holding Tank
D Incinerator Toilet
D Individual l-agoon
E Intermittcnt SF
E lntrcnch SF
tr Tank Only
tr Pit Privy
E Pressurized DF
E Recirculating GF
E RV Dump Station
E Sand Mound
E Seepage Pit
tr Steep Slope Drainfield
E Two Cell Lagoon
E Vault Priry
E Other (see below)
E Private
tr Shared
E Public
Water Source
E Basic System
E Complex System
E Well
tr Spring
Conditions of ADproval:
lnsDection required before cover 48 Hours advanced notice required for inspection
48 Eljen module units required
This permitted system requires the use of an a pproved medium grade sand (ASTM C-33)
Eljen system requires outlet baffle filter to be inslalled
Maximum depth of excavation 36 inches
System will need a vent pipe if 4" system pipe is more than 18" below grade
Downgraded two soil subgroup for sizing due to rock content, equals a 81
E Residential permit
E Non-residential permit
Soil Type:
0 Bedrooms
Gallons Pet Day
Galloas Per Day
USDA
Gallons
Squarr Fcet
Feet
600
A-2a
The minimum septic tank capacity is:1200
The minimum effective drainfield absorption area is:750
The drainfeld can be no closer to permanent/intermittent surface water than 300
Note: Final approval of this permit requires inspection of the uncovered system.
See page 2 for additional terms and conditions.
CA,rrt'
EHS Signaturc
06t1112024
Revision Date 0310512021
Date lssued
Applicant's Name:
O*"nen Name:
Property Address :
Legal Description:
PERMIT-Subsurface Sewage Disposal
EASTERN IDAHO PUBLIC HEALTH
1250 HOLLIPARK DRIVE permir # :
IDAHO FALLS lD 83401 D€te:
(208) 523-5382 P..rrl l:0611112024
RP05TS80020020hrhlicHcalth
ldaho htblic Hcalth Districts
Justin Rasmussen
Justin Rasmussen
Applicart'* Notttc:
Ownr'rs Nanr::
Pm;rrty Addrcss:
Lf,lnl Dcscripioo:
2959 G(izzly Lane Rexburg lO 83440
Tou nship 5N Rontc 39E S'x1ioo 23
Subdivision: TEXAS SIDING BUSINESS PARK LoI 2 Block 2 Sizcr*'.'r 4.74
Thir permit expires if the system is not constructed as approved within two years from the date issued.
Once the eystem is conetructed and approved by the Health Olstrkt, all requirements of the approved
plans and speci{ications, perrnit and permit application {including operations, maintEnance, monitoring
and reporling) are eppllceble Indefinitely and convey through transfer ol property ownership unless the
iystem is abandoned, remwed, replaced, or the permit is renewed. A permit may be renewed if the
permit application is received on or before the expiration date of the previous Fermit. Prior io a tranefe.
of property, the transferor murt inform the transferee of all applicable requirementt of the permit and
application- Feilurp to satisly the permit or application requirements may result in enlorcement action.
3324047