HomeMy WebLinkAboutREDLINED PLOT PLAN - 23-00089 - Manufab - New Commercial ShopAuthor Name Author Email Author Phone No.:
Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314
Description : Manufab - New Commercial Shop
Address : RP05TSB0020020
Application Type :
Document Filename : plot plan for manufab.pdf Array
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report
Revisions Required
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
Pg 1 Callout Stan Crittenden : Fire Open 1 IFC 2018 section 503.1.1 requires that a fire department access
road min. of 20 ft. wide, reach to with 150 ft. of all portions of
the building.
Pg 1 Free Text Stan Crittenden : Fire Open 1 County amended code requires
inside turning radius to be minimum
of 30 ft. and outside turning radius of
45 ft minimum.
Pg 1 Free Text Stan Crittenden : Fire Open 1 Access road to meet all weather driving and support
a 75,000 lb vehicle.
# 23-00089
Madison County - Commercial
Please digitally re-submit all pages of the plan set in response to requested revisions
for our next review cycle, with noted items resolved.
Report Date: 02.23.2023
Approval of plans does not constitute approval of variance from code
Page 1 of 1
Powered by TCPDF (www.tcpdf.org)
652'-1"
2
8
4
'
-
9
"
5
0
'
-
0
"
30'-0"
10'-0"
6
0
'
-
0
"
1
5
'
-
0
"
15'-0"
6
0
'
-
0
"
479'-6" 136
'
-
0
"
drain field
septic tankwell
concrete
plat plan for manufab shop
Legal Description: TEXAS SIDING BUSINESS PARKLOT 2 BLOCK 205N39E SEC. 23Parcel NumberRP05TSB0020020
east s
i
d
e
d
r
i
v
e
IFC 2018 section 503.1.1
requires that a fire
department access road
min. of 20 ft. wide, reach
to with 150 ft. of all
portions of the building.
A ccess road to meet all weather driv ing and support
a 7 5,000 lb v ehicle.County amended code requires
inside turning radius to be minimum
of 30 ft. and outside turning radius of