Information Request:
The contractor requests that the strapping detailed around the overhead doors on detail 2/S2.0 be removed on
this project.
Response to Request:
This change is approved. The cross bracing provides diaphragm action back to the mid-unit shearwall and the
shearwall has plenty of capacity to resolve this load. No further changes are necessary.
This RFI and any attachments are to serve as supplement to the original structural plan set. This does not permit
or allow any alterations to the original design.