24004SB10022024MS
Compressive Strength of Concrete Test Specimens
Project Number:
24004
Cumulative Test Load Amount:
30
Project Name:
Teton River Temple
Test Location:
Teton River Temple St, STA: 75+50 10' RCL
Client:
The Church of Jesus Christ of Latter-day Saints
Admixtures:
Air entrainment
Contractor:
Depatco
Supplier:
Walters Ready Mix
Mix Number:
526AP
Date:
9/4/2024
Cylinder Log #:
694
Set #:
1
Entrained Air (%):
4.9
Concrete Temperature (°F):
60
Ambient Temperature (°F):
52
Unit Weight (PCF):
140.5
Tested By:
Travis Hutmacher
Date:
9/4/2024
Picked Up By:
Michelle S.
Pick Up Date:
9/5/2024
Pick Up Time:
1:33 PM
Max, Min Temperature:
77,63
Compressive Strength Data
Previous Test Results:
Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
A 7 9/11/2024 12.57 47275 3761 4,000.00 4
PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its
content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby
notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately.
4A7044E6-88F6-4287-A9DD-D360C63047D8 2
Current Break Testing:
Cylinder
ID:
Break
Age:
Break
Date:
Diameter
(in):
Area
(in^2):
Maximum
Load
(lbs):
Compressive
Strength
(psi):
Required
28 day
Strength
(psi):
Break
Type:
B 28 10/2/2024 4.000 12.57 61,825.0 4918 4,000.0 Type 2
C 28 10/2/2024 4.000 12.57 62,900.0 5004 4,000.0 Type 1
D 28 10/2/2024 4.000 12.57 61,210.0 4870 4,000.0 Type 1
Second Break Average:
4931
Date:
10/03/2024
Reviewed By:
Luke Hammar
Signature: