HomeMy WebLinkAboutPLANS - 22-00292 - Chad Erikson - New Commercial BldgCIEI,jAD ERIKSON - TENANT IMPROVMENT REXBURG, VICIMTY MAP PROJECT SITE REXBURG BUINESS PARK PH2 BLK 2 LOT 3 REXBURG, IDAHO IBC 2018 ANALYSIS ORIGONAL REVIEW TYPE OF CONST. OCCUPANCY GROUP ALLOWABLE BLDG. SQFT ALLOWABLE BLDG. HT. ALLOWABLE BLDG. STORIES TENANT BUILDOUT TYPE OF CONST. OCCUPANCY GROUP TOTAL SQFT BUILD OUT = 11 B S-1 NON SPRINKLED 17,500 SQFT 40' 2 II-B S-1/B 3,682 Sq Ft NON SPRINKLED 1,444 SQFT STORAGE 1,428 SQFT MAIN FLOOR 810 SQFT UPPER FLOOR ID 0 ---------------------------------� i ----------------------------- GENERAL NOTES 1. ALL CONSTRUCTION TO BE TO CURRENT ADOPTED CODES AND REGULATION OF REXBURG. 2. PROVIDE BARRIERS, FLAGMEN, FLASHERS, ETC. FOR PROTECTION OF THE PUBLIC DURING CONSTRUCTION. 3. PRIOR TO ANY EXCAVATION, CONTRACTOR TO VERIFY AND LOCATE ALL UNDER GROUND UTILITIES. 4. PROVIDE FIRE BLOCKING IN STUD WALLS PER IBC SECTION 716.2. BOTH VERTICALLY AND HORIZONTALLY AND AT CEILING INTERSECTIONS. 6. ALL PROJECT CONSTRUCTION TO MEET CURRENT IBC REQUIRIMENTS, INCLUDING DOOR HARDWARE, CLEARANCES, AND OTHER REQUIREMENTS. 7. DO NOT SCALE DRAWINGS. 8. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF SUBCONTRACTORS AND WORK. DRAWING INDEX DRAWING No. A1.1 A3.1 A4.1 S1.1 /lr Al rl']AI ARCHITECTURAL FLOOR PLANS BUILDING SECTIONS DOOR AND WINDOW SCHEDULE STRUCTURAL FRAMING PLANS BRENT A. McFARLAND AR-2561 ,JANUARY -7, 2023 STATE OF IDAHO N M M co 00 O N 2 v Q � X Q L- � m M � N 0 rn M a> 0=v 'Cu! I w U ®A W O 0 o ZU O m 3 Q N � L CONSULTANTS: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Pocatello, Idaho 83204 (208) 233-0501 Fax (801) 233-0529 ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 E. Center St. Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 X a H Z Z O z Lu 11! � lu A vz �u 1~u lU m W zo V o REVISION: DRAWN BY: JOB NO: RSM C12-1 CHECKED BY: DATE: JRlN JAN. '23 PLOT DATE: 6-21-23 DRAWING NO. FILE: 927—G1.1—CS * G1.1 GI.I OF 2,--ro„ 21-6" 1 MIN GLR LGND MIN GLRf A3 41" MAX WIDTH A3 3a" MIN E D BRENT A. McFARLAND AR-2561 19"' WIDTH MAX „ 17 MIN 11-1 6 MAX Al ' 17" MIN B o F AI 36" GRAB BAR 36" MIN ti z I A2 ® o A2 42" GRAB BAR IL XX �j O G G z z INSULATE EXPOSED z z TO DISPENSING E A3 IS" GRAB BAR PIPES OUTLET - z z - - •t Q o JANUARY "1, 2023 m - - f - FORWARD _ B PAPER TOWEL DISPENSER r- m o: J m m m g N r = = r m REACH m o STATE OF IDAHO FIN. FLR � � ~ ❑G z z CLEARANCE EARANCE TOILET PAPER HOLDER CL 6" MAX TOE 8" MIN KNEE I'-6" X I'-6" 36" MAX CLEARANCE CLEARANCE H MIRROR N DRINKING ®IWAL.LR LAVATORY, MIRROR 4 TOILET SEAT ELECTRIC WATEE �E 50AP D15PEN5ER FOUNTAIN URINAL WATER CLOSET WATER CLOSET 50AP 2I5PENOR COVER DISPENSER HAND DRYER RECEPTACLE ❑ W o 0 F WASTE RECEPTACLE X STANDARD HE I GHT REOU I REMENTS Of SCALE: I/4"= I'-O" m o N GENERAL NOTES & U TI 12 min STANDARD ACCESSIBILITY 0 co 00 '^ j O 18 min v I. GRAB BARS MUST NOT ROTATE WITHIN THEIR FITTING5 v'A, Q 32 min 32 min 32 min 2. FLUSH VALVE HANDLE ® 44" MAX AFF (ON WIDE SIDE OF TOILET v, 0 3. 0 OE WHERE APPLICABLE) m 36 min E PROVIDE A MIN. CLEAR FLOOR SPACE OF 3OX48 WITH 14" MAX. EXTENDING UNDER LAVATORY/DRINKING FOUNTAIN TO INSULATED r' o Q0 4. 51 L55 MAX FORGE TO OPERATE FLUSH VALVE 8 ACTIVATE �O GONTROL5 5. ITEMS SHOWN HERE ARE FOR INFORMATION ONLY. GENERAL CONTRACTOR TO VERIFY ALL APPLICABLE ITEMS 8 MOUNT PER CONSULTANTS: ADA REQUIREMENT5 WHERE APPLICABLE. 6. FAUCETS MUST BE LEVER TYPE, ELECTRONICALLY ACTIVATED, OR APPROVED SELF - CL051N6 VALVES (MIN. 10 SEC OPEN FLO4, MECHANICAL ENGINEERING AND BE OPERABLE W/ONE HAND, NOT REQUIRING TIGHT GRASPING, ENGINEERED SYSTEMS ASSOC. PINGHING OR TH15TINC7 OF WRIST. 1355 East Center (A) (B) (C) (B) (C) (D) 7. ALL DOORS IN THE PUBLIC AND COMMON USE AREAS SHALL Pocatello, Idaho 83204 hinged door sliding door folding door front approach, pull side front approach, push side front approach, push side, door hinge approach, pull side COMPLY WITH AN51 AI17.1 INGLUDING NECESSARY MANEUVERING (208) 233-0501 provided with both closer latch CLEARANCES AND AGCE551BLE DOOR HARDWARE Fax (801) 233-0529 provoser an8. ALL DOORS SHALL HAVE 32" MIN. CLEAR WIDTH WHEN DOOR 15 ELECTRICAL ENGINEERING DOOR OFEN I NG A 1 DTH REOU I REMENTS CLEARANCE AT D9. ALL PLLUU DOOR APPROACH OPEN DEGREES PAYNE ENGINEERING INC. MBING FIXTURES 8 APPLIANCES SHALL HAVE MIN. 30 X 1823 E. Center St. 48 CLEAR FLOOR SPACE Pocatello, Idaho 83201 5GALE: N.T.5. 5GALE: N.T.5. 10. ALL PLUMBING FIXTURES, APPLIANCES 8 TELEPHONES IN PUBLIC AND COMMON USE AREAS SHALL COMPLY WITH A.D.A., IBG AND (208) 232-4439 AN51 111.1 Fax (208) 232-1435 E 60" MIN E 22 min E 22 min co N 16" MIN. 16" MIN. 42" MINe- L I6-18" 1424 min E 16" MIN. � � N 42 min E c OD 24 min 24 min L E E 00 N 1 F G (H) (I) J 0\\ = (E) ( ) ( ) () N hinge approach, pull side hinge approach, push side hinge approach, push side, door latch approach, pull side latch approach, pull side, latch approach, push side provided with both closer and latch door provided with closer to 6 7„ MIN CLEARANCE AT DOOR APPROACH � 4 z 50ALE: N.T.5. Q 145 30x48 lu 24 min E 00 18 min 0 z V E tu E (� A E o N 22 min E E 24 min co7 Z co CN L N 7e � '_=f X > 8 TYF I GAL ACCESS 15LE TOILET ROOM CLEARANCES 111 cn 5GALE: 1/2 -I -O u z (K) (M) (N) (0) (P) latch approach, push side, front approach side approach pocket or hinge approach stop or latch approach pull side v door provided with closer T_ CLEARANCE AT DOOR A1010ROAGH A 5GALE: N.T.5. L,-I Q m 7 12 min w Z E E 00 00 o X > 8 � X>g � 48 min 48 min r 48 min REVISION: DRAWN BY: JOB NO: (Q) (R) (A) (B) (C) push side push side, door provided with STAFF q27 both closer and latch I CHECKED BY: DATE: CLEARANCE AT DOOR APPROACH CLEARANCE BETAEEN DOORS JRW JAN. '23 SCALE: N.T.S. SCALE: N.T.S. PLOT DATE: 6-21-23 DRAWING NO. FILE: 927—G1.1—CODE * G1.2 G1.2 OF 2 MAIN FLOOR PLAN SCALE: 1/8" = I'-O" i. � i I I I III III MAIN FLOOR PLAN SCALE: 1/8" = 1'-0" UPPER FLOOR PLAN SCALE: 1/8N = 1:-0" 7 7 T vd d 8 UPPER FLOOR PLAN SCALE: 1/8" = 1'-0" 109 US 001 to] 051 W 0 a_ LJ Q H U LJ 2 U Q LJ _ F- 0 z W 0 Z O U Z LJ H Q' 3 a 3 Q W A 0 z W 6a (1 LO z 3 o' a a w V) D a W N_ O 2 H Q Z M Z Q J O Z U is Z Q a_ _ W z 3 a J Q F- H Z Q LJ w U LJ 2 U Q W A z Q a_ O U r oa a w U LJ H O a_ LJ Q Z l7 V) W A A Z l7 Z 3 w p U J J a_ (13 LJ H Q U O V) 0 Q 3 Cz 10 BRENT A. McFARLAND AR-2561 JANUARY -7, 2025 STATE OF IDAHO Fz N N 00 Lu 00 O N 2 v o x m 0� m N U' 0F3C4 F3C> � W W U wO o O Z U m � Q N 3 CONSULTANTS: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Pocatello, Idaho 83204 (208) 233-0501 Fax (801) 233-0529 ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 E. Center St. Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 0 Q Oz Of Q z Z V1 V 7- IL m JO "LLI ~O U Z D � I IL REVISION: DRAWN BY: JOB NO: RSM 92-1 CHECKED BY: DATE: JRW JAN. '25 PLOT DATE: 6-21-23 DRAWING NO. FILE: 927-A1.1-FP * A1.1 ALI OF WGJV I r r.L r. V^ I 1 Qo;N SCALE: 1/8" = I'-O" FINISHED FLOOR EAST ELEVATION SCALE: 1/8" = 1'-0" B A3.1 AEST ELEVATION FINISHED FLOOR SCALE: 1/8" = 1'-0" A3.1 A. ELEVATION 124'-0" TOP OF BAND roil TOP OF KALL =I Fm FE \,4F FINISHED FLOOR NORTH ELEVATION SCALE: 1/8" = I'-O" W pq H _ 0 0_ W ¢ H U w H U ¢ LJ 2 H L� 0 F-- z w z 0 U z W H I- 3 0 H 3 V) ¢ W 0 z V) w A V 0 z 3 Q 0 w V) D q w N H 0 _ D z D r z J 0 z 0 U Ca Z ¢ 0_ H 2 U W Z 3 0 J 0 z w U W 2 U ¢ W z ¢ 0_ 0 u r v4 q w U W H 0 0_ W ry V) z 2 V) w A ra z ¢ V) 0 z 3 ry q J J 0_ W I- ¢ U 0 V) V) 3 o' E BRENT A. McFARLAND AR-2561 JANUARY 7, 2023 STATE OF IDAHO N Co M M Lu O N 2 v a o x a CC O � m M Of N I rn Q :n M a> •� ao ® � o U) v I W W U W O >a tt®^^A M O ZO U m � Q N In ? CONSULTANTS: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Pocatello, Idaho 83204 (208) 233-0501 Fax (801) 233-0529 ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 E. Center St. Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 Q Z Oz w to - O 11� O _ F Q z � >,1, V O LLJ m U CD Z V LLI o REVISION: DRAWN BY: JOB NO: R5M Q27 CHECKED BY: DATE: JRYV JAN. '23 PLOT DATE: 6-21-23 DRAWING NO. FILE: 927-A2.1-XE * A2.1 A:2.1 4 OF ELEVATION 124'-0" TOP OF COLUMN ELEVATION 114' O" TOP OF COLUMN MAIN FRAME RAFTER ELEVATION•• • e 5U I Lip I NG SECTION 5GALE: 1/8" = 1'-0" 5GALE: I/8" = P-O" 12 COMP. MECH. 114'-O" ELEVATION 205 204 TOP OF GOLUMN 8 � HOTO STUD 10 104 � (p 5U I Ln I NG SECTION 5GALE: 1/8" = 1'-0" M 0 NOTES OI COMPACTED ENCG 1 NEERED FILL O2 6" FREE DRAINING 6RA1/EL O UNDER5LAB 1/APOR BARRIER O ASPHALT EMUL51ON O EXISTING FOOTING AND FOUNDATION O 4" GONG. SLAB - SEE 5TRUCT. O 11 J" TJ I FLOOR JO 15T5 O8 5/5" TYPE "X" GYPSUM WALL BOARD O CONCRETE STAIRS 10 1/2" CABLE HANDRAIL II 1/4" CONTINUOUS HAND RAIL 12 ACOU5TIC CEILING GRID IN OFFICES AND CORRIDOR UP STAIRS ra W PU 0 0_ w H U W H U ¢ Ld L� 0 F-- z W 0 z 0 u z w 3 0 3 V) ¢ W Q 0 V) z A w A V Lo z 3 ra W 0 W V) D q w N H 0 D z D r z J O H z 0 U n Z ¢ 0_ H 2 W z 3 0 J ¢ 0 z W U W 2 U ¢ W z ¢ 0_ 0 r v4 q W U W H 0 0_ W z A w A Q z ¢ V) 0 z 3 ry q J J 0_ W I- ¢ U 0 A V) 3 o' ME BRENT A. McFARLAND AR-2561 JANUARY -7, 2023 STATE OF IDAHO N N M CD O N 2 v Q � X u- ®mo � N Q� M •�� 00 ♦7 0 V v ® W W U ry� J O Q 0 Z� OQ m� N �n ? �3 CONSULTANTS: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Pocatello, Idaho 83204 (208) 233-0501 Fax (801) 233-0529 ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 E. Center St. Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 -- i07 Z � z tu Z Q z Z V • V Z l9 m wQ x W z Uf o REVISION: DRAWN BY: JOB NO: RSM Q27 CHECKED BY: DATE: JRW JAN. '25 PLOT DATE: 6-21-23 DRAWING NO. FILE: 927-A3.1-BS * A3.1 a I OF GLAZING LEGEND D 0 0 R S C H E D U L E 1. 1/4" TEMPERED, CLEAR D 0 0 R F R A M E HARDWARE LEGEND - Z CD 0 m m SIZE L`' w w w 0 >- J H J � w � 2 = Y Q = Z ILL]Q w_ w Q� = m Q CD � O � U LLJ (/) IV Q � Q � V)Lj p REMARKS Z � Z Z � Z 101A 0 0 — — — — — — — — — — — EXISTING DOOR NO WORK DARK DARK 102A ® 0 A3'—O" 6'-8" 13/4" ALUM ANOD. 0 B 2 ALUM ANOD. — — 105A 0 0 B 3'—O" 6'-8" 1 3/4" WOOD STAINED A I H.M. FAINT — — 1 j 104A 0 0 B 3'-0" 6'-8" 1-3/4" WOOD 5TA I NED A I H.M. FAINT — — } W —1 1045 0 0 G 3'-0" 6'-8" 1-3/4" METAL FAINT A I H.M. FAINT 45 MIN — z_ EXISTING DOOR NO WORK 105A 0 0 A 3'-0" (6'-8" 1 3/4" ALUM DARK ANOD.107A 0 B 2 ALUM DARKANOD — — ® 0 A 3'-0" 6'-8" 13/4" ALUM DARK ANOD. 0 B 2 ALUM DARK ANOD. — — 202A 0 0 A 3'-0" 6'-8" 1 3/4" ALUM DARK B 2 ALUM DARK ANOD. ANOD. 205A 0 0 B 3'-0" 6'-8" 1-3/4" WOOD 5TA I NED A I H.M. PAINT — — W 204A 0 0 B 3'-0" (6'-8" 1 3/4" WOOD. STAINED A I H.M. PAINT — — } W 205A 0 0 A 3'-0" 6'-8" 1-3/4" ALUM DARK B 2 ALUM DARK — — jDARK 206A 0 0 A 3'-0" (6'-8" 1-3/4" ALUM 0 B 2 ALUM DARK — — ANOD. ANOD. WINDOW SCHEDULE LLJ GLAZING TYPES 1 = 1/4" CLEAR H J Q 0 Z N REMARKS Q Q Z a J T= TEMPERED A ALUMINUM DARK ANOD. I T B ALUMINUM DARK ANOD. I T G ALUMINUM DARK ANOD. I T D ALUMINUM DARK ANOD. I T E ALUMINUM DARK ANOD. I T E ALUMINUM DARK ANOD. I T C7 ALUMINUM DARK ANOD. I T H ALUMINUM DARK ANOD. I T N$ N 12'-0" 41_2" 3'-O" 0 41_0 11 4'-0" 1 �V 3'-0" N 0 0 T ' m `r 0 iv DE DF AINPOA/DOOR TYPES SCALE: 1/4" - P-0" 8'-( 5'-011 31_OII N ID W Q v N w N SEE SGHED A ALUMINUM SEE 5GHED. SEE 5GHED. A � a w w C N B G WOOD METAL DOOR T'* fiFE9 SCALE: N.T.S. SEE SCHEDULE FRAME I TYFE5 SCALE: N.T.S. 4'-9" 4'-9" Ifl 4'-0" 4'-0" N I • H❑ 00 Ov' VA 10'-0" I. Al Al 0 2" U.N.O. N FIELD VERIFY ALL WALL v THICKNE55 PRIOR LTO ORDERING HOLLOW METAL A FRAME F R O F I L E 5 SCALE: N.T.S. P-301 Y J❑ WINDOW HEAD ELEV. 106-10" ELEV. 106'-10" WINDOW HEAD ALUMINUM STORE FRONT 5 ra w 0 tY a_ W ¢ H U W H H U tY ¢ W 2 H L� 0 F-- z w Z 0 u z w H 0 _ 3 ¢ w Q 0 z 0 V) w A V 0 z 3 Q 0 w V) q W N H 0 ¢ Z r z ¢ J O tY Z 0 U Ca Z ¢ 0_ H 2 U W Z 3 0 J ¢ 0 z w U W ¢ w Z ¢ a- 0 u r v4 W U w 0 a- w tY z 2 V) w A Q Z ¢ 0 z 3 q J J 0_ C1 W I— ¢ u 0 V) .6 3 BRENT A. McFARLAND AR-2561 ,JANUARY -7, 2023 STATE OF IDAHO N CD M M co 00 O N = v Q � X a LL ®mo a_ N Q � M ♦7 0 V v ® w W U O ry� JLd 0 m o oQ m< N �3 �3 CONSULTANTS: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Pocatello, Idaho 83204 (208) 233-0501 Fax (801) 233-0529 ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 E. Center St. Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 Q A z� Ot � � v V o Az Q Z _ v A Z m LL; ~O w � z O Uf � � o REVISION: DRAWN BY: JOB NO: R5M Q27 CHECKED BY: DATE: JRW JAN. '23 PLOT DATE: 6-21-23 DRAWING NO. FILE: 927-A4.1 DSWS * A4.1 A-4.1_ OF STRIXTURA . NOTES: 1. PROVIDE G' x 24' SHOVEL FOOT1N6 UNVER ALL BEAFUNS WALLS. PROVIDE 5W VIA. ANCHOR BOLTS • 46' OLe 2 TYPICAL DOOR OPBUNS, I TRII M • 1 KING STUD PER SIDE So TYPICAL WAl ATTACH 1/2' PIA. Abe YV V4S 50" "TE WASHERS AT 40' O.C. 4a FLOOR SHEATHINS, S/4' APA RATED FLOOR SHEATHMS W IOd COHMON NAILS AT b' OL, AT PANEL EPEES IO/ BOURY AND • I2' OL, IN THE FIELD _I m FOOT I NG PLAN 5GALE: 1/5" = 1'-0" UPPER FLOOR PRAM I NG PLAN 5GALE: 1/6" = 1'-0" Q W Pal H _ 0 a- L ry ¢ H U w H U ¢ Li 2 H L� 0 F-- z w z 0 U z W H F-- 3 0 3 V) ¢ W ca 0 z l7 V) L A Vi L3 z 3 Q 0 w V D q w N H 0 _ D z D r z J 0 z 0 U Ca Z ¢ CL H 2 V) W Z 3 0 J ¢ 0 z L IY U W 2 U ¢ W z ¢ 0 r v4 q L U W H 0 a- W V) z 2 V w A ca z V) 0 z 3 ry q J J CL C1 W F-- ¢ U 0 V) V, 3 E BRENT A. McFARLAND AR-2561 JANUARY -7, 2023 STATE OF IDAHO Iz: N M M Lu O N 2 v a o x a u— CC O � � m M � N rn 0I Q � Ih a> •� ao ® � o � v I W W U ®A W O 0 � O ZO U lT] � Q N � Hn ? CONSULTANTS: MECHANICAL ENGINEERING ENGINEERED SYSTEMS ASSOC. 1355 East Center Pocatello, Idaho 83204 (208) 233-0501 Fax (801) 233-0529 ELECTRICAL ENGINEERING PAYNE ENGINEERING INC. 1823 E. Center St. Pocatello, Idaho 83201 (208) 232-4439 Fax (208) 232-1435 Q Z z tu 11� � 1�1 � Q z cn Z V OL V Z l9 mw X � w z O a o REVISION: DRAWN BY: JOB NO: R5M Q27 CHECKED BY: DATE: JRYV JAN. '23 PLOT DATE: 6-21-23 DRAWING NO. FILE: 927-S1.1-FNTFND * S1.1 SI al OF