Corrections in the following table need to be applied before a permit can be issued
Review Report
Revisions Required
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
E1.0 Callout Alex Owens : Electrical Open 10 Available fault current calculation needed
# 22-00292
New Commercial Building
As per Resolution 2022-07, adopted April 6, 2022, new development is required to follow standards for the installation of fiber conduit and distribution boxes. Location of conduit
and distribution boxes need to be identified and shown on plans.
Report Date: 07.14.2022
Approval of plans does not constitute approval of variance from code
Page 1 of 1
Powered by TCPDF (www.tcpdf.org)
Author Name Author Email Author Phone No.:
Alex Owens Alex.Owens@rexburg.org 208-372-2330
Cody Jones Cody.Jones@rexburg.org 208-372-2173
Don Allen Don.Allen@rexburg.org 208-372-2174
Description : Chad Erickson New Commercial Bldg
Address : 309 Profit St Suites 1101-1104 - Rexburg Business Park PH2 Blk 2 Lot 3
Application Type :
Document Filename : Building Plans.pdf Array
Comment Author Contact Information:
Corrections in the following table need to be applied before a permit can be issued
Review Report
Revisions Required
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
G1.1 Free text Cody Jones : Building Open 1 Need an Envelope COMM check or prescriptive insulation form
signed.
Exit lighting and Exit signs need to comply with Sections 1008
and 1013.
All if any concealed spaces need fire blocked and draft
stopped.
G1.1 Free text Cody Jones : Building Open 1 Construction type VB?
Building B occupancy?
Total occupant load 72?
A1.1 Free text Cody Jones : Building Open 2 Restrooms need to meet all ADA requirements.
Buildings with an occupant load of more than 15 requires a
drinking fountain.
A1.1 Free text Cody Jones : Building Open 2 If construction type is VB, areas exceeds allowable area as per
table 506.3, will need to install a listed assembly fire
separation.
# 22-00292
New Commercial Building
Report Date: 05.09.2022
Approval of plans does not constitute approval of variance from code
Page 1 of 2
See Com check attached
Acknowledged
Acknowledged
Building type to be IIB
warehouse occupancy 21
A portable water station will
be provided for the space
Construction type to be IIB
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
A3.1 Free text Cody Jones : Building Open 4 Damp proofing and water proofing needs to comply with
Section 1805
Site grading to meet requirements of Section 1804.4
A4.1 Free text Cody Jones : Building Open 5 Landings at doors to need to meet the requirements of section
1010.
C2 Free text Cody Jones : Building Open 7 Special inspector needs to be identified as per 1704.2.1.
G1.1 Free text Alex Owens : Electrical Open 1 No electrical plans provided. Please provide electrical plans
including service size, available fault current calculation for the
service, wiring method (whether nm cable, mc cable, or
conduit is required/acceptable). All work must comply with
2017 NEC requirements.
Report Date: 05.09.2022
Approval of plans does not constitute approval of variance from code
Page 2 of 2
Powered by TCPDF (www.tcpdf.org)
Acknowledged
Acknowledged
Acknowledged
See attached electrical riser
plan
Connect Engineering is under contract
COMcheck Software Version COMcheckWeb
Envelope Compliance Certificate
Project Title:
2018 IECC
Project Type:New Construction
Vertical Glazing / Wall Area:7%
Location:Rexburg, Idaho
Climate Zone:6b
Construction Site:Owner/Agent:Designer/Contractor:
Project Information
Energy Code:
Chad Erikson
Credits: 1.0 Required 1.0 Proposed
Enhanced Envelope Performance, 1.0 credit
Additional Efficiency Package(s)
Building Area Floor Area
1-Warehouse : Nonresidential 10800
Envelope Assemblies
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Roof: Metal Building, Standing Seam, Single Insulation Layer
with Thermal Blocks (e), [Bldg. Use 1 - Warehouse]
10800 0.0 36.0 0.027 0.031
Floor: Unheated Slab-On-Grade, Vertical 3 ft., [Bldg. Use 1 -
Warehouse] (d)
380 ---10.0 0.510 0.540
NORTH
Ext. Wall: Metal Building Wall, Single Layer Mineral Fiber
(compressed at girt), [Bldg. Use 1 - Warehouse]
8160 0.0 30.0 0.032 0.052
Window: Metal Frame with Thermal Break: Fixed, Perf. Specs.:
Product ID 550, SHGC 0.33, [Bldg. Use 1 - Warehouse] (c)
508 ------0.340 0.360
Door: Insulated Metal, Swinging, [Bldg. Use 1 - Warehouse]98 ------0.340 0.370
Door: Other (U-Factor option), Garage door 14% glazing, [Bldg.
Use 1 - Warehouse]
286 ------0.340 0.310
Door: Glass (over 50% glazing): Metal Frame, Entrance Door,
Perf. Specs.: Product ID 6060-T6, SHGC 0.33, [Bldg. Use 1 -
Warehouse] (c)
84 ------0.340 0.770
(a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b)'Other' components require supporting documentation for proposed U-factors.
(c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(d)Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
(e)Thermal spacer block with minimum R-3.5 must be installed above the purlin/batt, and the roof deck secured to the
purlins.
Project Title:
Data filename:
Chad Erikson 06/13/22Report date:
81 ofPage
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
designed to meet the 2018 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable
mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Envelope PASSES: Design 4% better than code
Project Title:
Data filename:
Chad Erikson 06/13/22Report date:
82 ofPage
Ryan Malm A.I.T.06/27/2022
CI
T
Y
R
E
V
I
E
W
6
/
2
7
/
2
0
2
2
CI
T
Y
R
E
V
I
E
W
6
/
2
7
/
2
0
2
2
CI
T
Y
R
E
V
I
E
W
6
/
2
7
/
2
0
2
2
CI
T
Y
R
E
V
I
E
W
6
/
2
7
/
2
0
2
2
3333
4
1
1 1 1
2
2 2 2
COMM BOARD
MULTI METER PACK. SEE
POWER RISER
MMP
CONSULTANTS:
TEP
889
JUNE 2022
11
5
2
B
O
N
D
A
V
E
N
U
E
-
S
u
i
t
e
A
RE
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
VO
I
C
E
(
2
0
8
)
3
5
9
-
2
3
0
9
FA
X
(
2
0
8
)
3
5
9
-
2
2
7
1
WW
W
.
J
R
W
A
.
C
O
M
E
D
L
R
E
E
N
I
G
NE
OHADIFOET
A
T
ENYAPDDOT
8270S
RETSIGER
ANOISSEFORP
RE
X
B
U
R
G
,
ID
A
H
O
MECHANICAL ENGINEERING
ELECTRICAL ENGINEERING
ORIGINAL SIGNED BY:
TODD E. PAYNE
DATED ORIGINAL SIGNED:
8-11-2022
ON FILE AT:
PAYNE ENGINEERING INC.
CH
A
D
E
R
I
K
S
O
N
NE
W
B
U
I
L
D
I
N
G
P.E. JOB #2285
Pocatello, Idaho 83201
Engineering Inc.
1823 E. Center
tel (208) 232-4439
Consulting Engineers
www.payneengineeringinc.com
E1.0
EL
E
C
T
R
I
C
A
L
P
L
A
N
KEY NOTES
1 2" CONDUIT FROM COMM BOARD TO EACH TENANT SPACE FOR IT SERVICES.
STUB 36" BEYOND DEMISING WALL.
3" CONDUIT STUBBED 3FT. BEYOND DEMISING WALL FOR FUTURE TENANT.
POWER (200A) FROM MULTI-METER PACK.
3/4" CONDUIT STUBBED THROUGH WALL FOR FUTURE POWER CONDUCTORS TO
RECEPTACLE.
PROVIDE AND INSTALL (1) 4" AND (2) 2" CONDUITS WITH PULL ROPE FROM
COMM. BOARD TO PROPERTY LINE FOR COMM. SERVICES. COORDINATE WITH
SITE.
2
3
4
SCALE:
MAIN PLAN - ELECTRICAL
1/8" = 1' - 0"16'8'0"
M
M
M
GROUND
PER NEC
600 AMP
MULTI-METER
PACK
(2) SETS 4"C., 3-#500 AL
POWER COMPANY
TRANSFORMER
3" CONDUIT TO EACH
TENANT SPACE
NO SCALE
POWER RISER DIAGRAM
CONC. PAD BY E.C.
200A
200A
200A
120/240V 1Ø 3W
CONDUIT TO EXTEND A MIN.
SERVICE GROUNDING DETAIL
OF 3" ABOVE MUD SILL
GRND. CLAMP & CONNECTOR
W/REVERSIBLE CONTACT PLATE
CONDUIT TO WATER
1" GRND. SERVICE
(20' MIN. LENGTH)
#2/O BARE COPPER WIRE
1" RIGID PVC CONDUIT
SERVICE GRND. CONDUCTOR
(CONTINUOUS)
TYPICAL CONCRETE
FOUNDATION FOOTING
2"
M
I
N
.
3"
M
A
X
.
CONDUIT TO GRND ROD
1" GRND SERVICE
MAIN
FINISHED FLOOR
COPPER GRND ROD
5/8" x 10"
1'
-
0
FLOOR (CONTINUOUS)
GRND CONDUCTOR
PANEL GRND LUGS
BLDG. GRND TO MAIN
WATER MAIN
M
200A
16,674 AFC