Loading...
HomeMy WebLinkAboutCONCRETE SECOND BREAK - 23-00170 - Rexburg 10th Ward LDS MeetinghousePRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7F53AC33-A7B0-485F-95D3-52DBC693CE1F 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB0952023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 11.0 Project Name: Married Student Second Stake Test Location: Footings on North edge of building Client: The Church of Jesus Christ of Latter-day Saints Admixtures: MP 322 Contractor: Alpha Concrete Construction Supplier: Walters Ready Mix, Inc. Mix Number: W170-F 35 Date: 8/8/2023 Cylinder Log #: 445 Set #: 1 Entrained Air (%): 3.0 Concrete Temperature (°F): 72 Ambient Temperature (°F): 71 Unit Weight (PCF): 147.0 Tested By: Leland Stiener Date: 8/8/2023 Picked Up By: Jense Christensen Pick Up Date: 8/9/2023 Pick Up Time: 1:45 PM Max, Min Temperature: 80,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/15/2023 12.57 39360 3131 3,000.00 Type 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7F53AC33-A7B0-485F-95D3-52DBC693CE1F 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 9/5/2023 4.000 12.57 55195.0 4391 3000.0 Type 6 C 28 9/5/2023 4.000 12.57 54470.0 4333 3000.0 Type 3 D 28 9/5/2023 4.000 12.57 55995.0 4455 3000.0 Type 3 Second Break Average: 4393 Date: 09/05/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F39E3D37-D651-48D9-AA81-B8618D133D91 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB07032024MS Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 9 Project Name: Married Student Second Stake Test Location: Northeast corner of northeast utility pad. Client: The Church of Jesus Christ of Latter-day Saints Admixtures: N/A Contractor: Okland Construction Supplier: Walters Ready Mix, Inc. Mix Number: 4500AF Date: 6/4/2024 Cylinder Log #: 351 Set #: 1 Entrained Air (%): 4.9 Concrete Temperature (°F): 69 Ambient Temperature (°F): 71 Unit Weight (PCF): 140.6 Tested By: Tyler Jones Date: 6/4/2024 Picked Up By: Michelle S. Pick Up Date: 6/6/2024 Pick Up Time: 1:52 PM Max, Min Temperature: 75,63 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 6/12/2024 12.57 47595 3786 3,000.00 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. F39E3D37-D651-48D9-AA81-B8618D133D91 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 7/3/2024 4.000 12.57 61,975.0 4930 3,000.0 Type 1 C 28 7/3/2024 4.000 12.57 62,905.0 5004 3,000.0 Type 1 D 28 7/3/2024 4.000 12.57 62,770.0 4994 3,000.0 Type 1 Second Break Average: 4976 Date: 07/10/2024 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7277D0EA-A23F-4703-AE64-016DC631A399 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB07092024LSH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 9 Project Name: Married Student Second Stake Test Location: Curb on south west corner of building Client: The Church of Jesus Christ of Latter-day Saints Admixtures: Air entrainment Contractor: Rad Crete Supplier: Walters Ready Mix Mix Number: 4500AF Date: 7/2/2024 Cylinder Log #: 474 Set #: 1 Entrained Air (%): 5.0 Concrete Temperature (°F): 70 Ambient Temperature (°F): 61 Unit Weight (PCF): 141.6 Tested By: Leland Steiner Date: 7/2/2024 Picked Up By: Michelle S. Pick Up Date: 7/3/2024 Pick Up Time: 3:54 PM Max, Min Temperature: 74,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 5 7/7/2024 12.57 50035 3981 3,000.00 2 C 6 7/8/2024 12.57 53395 4248 3,000.00 2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7277D0EA-A23F-4703-AE64-016DC631A399 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: D 7 7/9/2024 4.000 12.57 54,965.0 4373 3,000.0 Type 1 Second Break Average: 4373 Date: 07/10/2024 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. FC40CD35-A38D-49A8-AF58-819AD79BAA87 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB07232024MS Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 10 Project Name: Married Student Second Stake Test Location: SE corner of lot curb Client: The Church of Jesus Christ of Latter-day Saints Admixtures: AE-90, 322 N Contractor: Radcrete Supplier: Walters Ready Mix Mix Number: 4500AF 10WC51 Date: 6/25/2024 Cylinder Log #: 443 Set #: 1 Entrained Air (%): 4.5 Concrete Temperature (°F): 72 Ambient Temperature (°F): 57 Unit Weight (PCF): 141.6 Tested By: James Russo Date: 6/25/2024 Picked Up By: Michelle S. Pick Up Date: 6/26/2024 Pick Up Time: 11:54 AM Max, Min Temperature: 75,61 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 7/2/2024 12.57 63855 5080 3,000.00 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. FC40CD35-A38D-49A8-AF58-819AD79BAA87 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 7/23/2024 4.000 12.57 77,960.0 6202 3,000.0 Type 3 C 28 7/23/2024 4.000 12.57 80,005.0 6365 3,000.0 Type 2 D 28 7/23/2024 4.000 12.57 78,065.0 6210 3,000.0 Type 2 Second Break Average: 6259 Date: 07/23/2024 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 90C33423-3580-4AEC-8874-BE9C3A9B926E 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB07242024MS Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 10 Project Name: Married Student Second Stake Test Location: Sidewalk curb 50 ft E of NE corner of bullding Client: The Church of Jesus Christ of Latter-day Saints Admixtures: Air Contractor: Alpha Concrete Construction Supplier: Walters Ready Mix Mix Number: 4500AF 10WC187 Date: 6/26/2024 Cylinder Log #: 451 Set #: 1 Entrained Air (%): 6.4 Concrete Temperature (°F): 77 Ambient Temperature (°F): 62 Unit Weight (PCF): 138 Tested By: James Russo Date: 6/26/2024 Picked Up By: Michelle S. Pick Up Date: 6/27/2024 Pick Up Time: 10:21 AM Max, Min Temperature: 78,62 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 7/3/2024 12.57 50525 4019 4,000.00 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 90C33423-3580-4AEC-8874-BE9C3A9B926E 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 7/24/2024 4.000 12.57 55,500.0 4415 4,000.0 Type 2 C 28 7/24/2024 4.000 12.57 54,750.0 4356 4,000.0 Type 1 D 28 7/24/2024 4.000 12.57 56,915.0 4528 4,000.0 Type 5 Second Break Average: 4279 Date: 07/24/2024 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. CEA3EDE2-7F27-45BC-9A38-63AE187928D0 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB07302024MS Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 9 Project Name: Married Student Second Stake Test Location: Curb on south west corner of building Client: The Church of Jesus Christ of Latter-day Saints Admixtures: Air entrainment Contractor: Rad Crete Supplier: Walters Ready Mix Mix Number: 4500AF Date: 7/2/2024 Cylinder Log #: 474 Set #: 1 Entrained Air (%): 5.0 Concrete Temperature (°F): 70 Ambient Temperature (°F): 61 Unit Weight (PCF): 141.6 Tested By: Leland Steiner Date: 7/2/2024 Picked Up By: Michelle S. Pick Up Date: 7/3/2024 Pick Up Time: 3:54 PM Max, Min Temperature: 74,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 5 7/7/2024 12.57 50035 3981 3,000.00 2 C 6 7/8/2024 12.57 53395 4248 3,000.00 2 D 7 7/9/2024 12.57 54965 4373 3,000.00 1 A 4 7/6/2024 12.57 0 3,000.00 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. CEA3EDE2-7F27-45BC-9A38-63AE187928D0 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: E 28 7/30/2024 4.000 12.57 68,080.0 5416 3,000.0 Type 1 F 28 7/30/2024 4.000 12.57 61,295.0 4876 3,000.0 Type 5 G 28 7/30/2024 4.000 12.57 64,585.0 5138 3,000.0 Type 2 Second Break Average: 5143 Date: 07/30/2024 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. FF2D923C-DC97-48C9-8215-2E74B7DD7927 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB08072023JPC Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 10 Project Name: Married Student Second Stake Test Location: Southern foundation walls Client: The Church of Jesus Christ of Latter-day Saints Admixtures: DELVO, MP322, MA AE 90 Contractor: Headwaters Construction Supplier: Walters Concrete Mix Number: 4500AF-45 Date: 8/1/2023 Cylinder Log #: 432 Set #: 1 Entrained Air (%): 5.0 Concrete Temperature (°F): 73 Ambient Temperature (°F): 87 Unit Weight (PCF): 140.6 Tested By: Mark Mansfield Date: 8/1/2023 Picked Up By: Pick Up Date: Pick Up Time: Max, Min Temperature: Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 3 8/4/2023 12.57 57040 4538 4,500.00 Type 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. FF2D923C-DC97-48C9-8215-2E74B7DD7927 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 6 8/7/2023 4.000 12.57 66,285.0 5273 4,500.0 Type 3 Second Break Average: 5273 Date: 08/08/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 612B66D8-5C11-4342-AFAA-1571F2451939 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB08082023JPC Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 10 Project Name: Married Student Second Stake Test Location: Southern foundation walls Client: The Church of Jesus Christ of Latter-day Saints Admixtures: DELVO, MP322, MA AE 90 Contractor: Headwaters Construction Supplier: Walters Concrete Mix Number: 4500AF-45 Date: 8/1/2023 Cylinder Log #: 432 Set #: 1 Entrained Air (%): 5.0 Concrete Temperature (°F): 73 Ambient Temperature (°F): 87 Unit Weight (PCF): 140.6 Tested By: Mark Mansfield Date: 8/1/2023 Picked Up By: Luke Hammar Pick Up Date: 8/2/2023 Pick Up Time: 8:19 AM Max, Min Temperature: 80,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 3 8/4/2023 12.57 57040 4538 4,500.00 Type 1 B 6 8/7/2023 12.57 66285 5273 4,500.00 Type 3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 612B66D8-5C11-4342-AFAA-1571F2451939 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: C 7 8/8/2023 4.000 12.57 70,860.0 5637 4,500.0 Type 1 Second Break Average: 5637 Date: 08/09/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8646AB0D-50FE-423A-861B-F59D79264536 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB08152023JPC Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 10.0 Project Name: Married Student Second Stake Test Location: Southern foundation walls Client: The Church of Jesus Christ of Latter-day Saints Admixtures: DELVO, MP322, MA AE 90 Contractor: Headwaters Construction Supplier: Walters Concrete Mix Number: 4500AF-45 Date: 8/1/2023 Cylinder Log #: 432 Set #: 1 Entrained Air (%): 5.0 Concrete Temperature (°F): 73 Ambient Temperature (°F): 87 Unit Weight (PCF): 140.6 Tested By: Mark Mansfield Date: 8/1/2023 Picked Up By: Luke Hammar Pick Up Date: 8/2/2023 Pick Up Time: 8:19 AM Max, Min Temperature: 80,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 3 8/4/2023 12.57 57040 4538 4,500.00 Type 1 B 6 8/7/2023 12.57 66285 5273 4,500.00 Type 3 C 7 8/8/2023 12.57 70860 5637 4,500.00 Type 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 8646AB0D-50FE-423A-861B-F59D79264536 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: D 14 8/15/2023 4.000 12.57 75,180.0 5981 4,500.0 Type 1 Second Break Average: 5981 Date: 08/16/2023 Reviewed By: E. Vail Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 42B23C25-95B2-4F4D-9A84-1B95F94A2881 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB08222023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 8.5 Project Name: Married Student Second Stake Test Location: F-1 Client: The Church of Jesus Christ of Latter-day Saints Admixtures: MP 322 Contractor: Alpha Concrete Construction Supplier: Walters Ready Mix Mix Number: W170-F 35 Date: 7/25/2023 Cylinder Log #: 418 Set #: 1 Entrained Air (%): 2.0 Concrete Temperature (°F): 80 Ambient Temperature (°F): 86 Unit Weight (PCF): 139.8 Tested By: Bryce Choffin Date: 7/25/2023 Picked Up By: B. Choffin Pick Up Date: 7/26/2023 Pick Up Time: 8:10 AM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/1/2023 12.57 44105 3509 3,000.00 Type 2 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 42B23C25-95B2-4F4D-9A84-1B95F94A2881 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 8/22/2023 4.000 12.57 51085.0 4064 3000.0 Type 1 C 28 8/22/2023 4.000 12.57 50185.0 3992 3000.0 Type 1 D 28 8/22/2023 4.000 12.57 52610.0 4185 3000.0 Type 2 Second Break Average: 4080 Date: 08/23/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EE41CFF8-50CB-400D-A902-F589695D4B79 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB08292023LSH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 10.0 Project Name: Married Student Second Stake Test Location: Southern foundation walls Client: The Church of Jesus Christ of Latter-day Saints Admixtures: DELVO, MP322, MA AE 90 Contractor: Headwaters Construction Supplier: Walters Concrete Mix Number: 4500AF-45 Date: 8/1/2023 Cylinder Log #: 432 Set #: 1 Entrained Air (%): 5.0 Concrete Temperature (°F): 73 Ambient Temperature (°F): 87 Unit Weight (PCF): 140.6 Tested By: Mark Mansfield Date: 8/1/2023 Picked Up By: Luke Hammar Pick Up Date: 8/2/2023 Pick Up Time: 8:19 AM Max, Min Temperature: 80,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 3 8/4/2023 12.57 57040 4538 4,500.00 Type 1 B 6 8/7/2023 12.57 66285 5273 4,500.00 Type 3 C 7 8/8/2023 12.57 70860 5637 4,500.00 Type 1 D 14 8/15/2023 12.57 75180 5981 4,500.00 Type 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EE41CFF8-50CB-400D-A902-F589695D4B79 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: E 28 8/29/2023 4.000 12.57 77060.0 6130 4500.0 Type 1 F 28 8/29/2023 4.000 12.57 80380.0 6395 4500.0 Type 1 G 28 8/29/2023 4.000 12.57 77800.0 6189 4500.0 Type 1 Second Break Average: 6238 Date: 08/30/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 0E4C995A-5AEB-4351-A237-07310BAF7332 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB08312023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 9.8 Project Name: Married Student Second Stake Test Location: Southwest corner of building, foundation walls Client: The Church of Jesus Christ of Latter-day Saints Admixtures: DELVO, MP 322, MA AE 90 Contractor: Alpha Concrete Construction Supplier: Walters Ready Mix, Inc. Mix Number: 4500AF-45 Date: 8/3/2023 Cylinder Log #: 434 Set #: 1 Entrained Air (%): 5.5 Concrete Temperature (°F): 80 Ambient Temperature (°F): 70 Unit Weight (PCF): 138.6 Tested By: Michael Hammar Date: 8/3/2023 Picked Up By: L. Steiner Pick Up Date: 8/4/2023 Pick Up Time: 11:31 AM Max, Min Temperature: 79.6,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/10/2023 12.57 46130 3670 4,500.00 Type 3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 0E4C995A-5AEB-4351-A237-07310BAF7332 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 8/31/2023 4.000 12.57 58115.0 4623 4500.0 Type 3 C 28 8/31/2023 4.000 12.57 57965.0 4611 4500.0 Type 1 D 28 8/31/2023 4.000 12.57 57445.0 4570 4500.0 Type 3 Second Break Average: 4601 Date: 09/01/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 83C84CDD-086F-4776-B4F3-A9082F4D48BD 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB09192023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 10.0 Project Name: Married Student Second Stake Test Location: Footings for interior of building on south half Client: The Church of Jesus Christ of Latter-day Saints Admixtures: MP 322 Contractor: Alpha Concrete Supplier: Walters Ready Mix, Inc. Mix Number: W170-F 35 Date: 8/22/2023 Cylinder Log #: 488 Set #: 1 Entrained Air (%): 1.4 Concrete Temperature (°F): 71 Ambient Temperature (°F): 80 Unit Weight (PCF): 145.0 Tested By: Leland Stiener Date: 8/22/2023 Picked Up By: Matthew Hammar Pick Up Date: 8/23/2023 Pick Up Time: 11:17 AM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/29/2023 12.57 41770 3323 3000 Type 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 83C84CDD-086F-4776-B4F3-A9082F4D48BD 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 9/19/2023 4.000 12.57 54910.0 4368 3000.0 Type 1 C 28 9/19/2023 4.000 12.57 55840.0 4442 3000.0 Type 1 D 28 9/19/2023 4.000 12.57 56045.0 4459 3000.0 Type 6 Second Break Average: 4423 Date: 09/22/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EFA7DA78-DBB8-425B-9BA2-0BF168AC6554 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB09192024MS Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 10 Project Name: Married Student Second Stake Test Location: 43.8032400, -111.7970208 Client: The Church of Jesus Christ of Latter-day Saints Admixtures: AE-90 171.0, 322 N 328.0 Contractor: Rad Crete Supplier: Walters Ready Mix, Inc. Mix Number: 4500AF Date: 8/22/2024 Cylinder Log #: 657 Set #: 1 Entrained Air (%): 5.0 Concrete Temperature (°F): 67 Ambient Temperature (°F): 58 Unit Weight (PCF): 142 Tested By: Nathaniel Speas Date: 8/22/2024 Picked Up By: Michelle S. Pick Up Date: 8/23/2024 Pick Up Time: 1:46 PM Max, Min Temperature: 75,62 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/29/2024 12.57 63150 5024 3,000.00 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. EFA7DA78-DBB8-425B-9BA2-0BF168AC6554 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 9/19/2024 4.000 12.57 76,060.0 6051 3,000.0 Type 2 C 28 9/19/2024 4.000 12.57 71,585.0 5695 3,000.0 Type 2 D 28 9/19/2024 4.000 12.57 74,660.0 5940 3,000.0 Type 1 Second Break Average: 5895 Date: 09/20/2024 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DD1D6409-2C8B-4187-90DC-425C09BC7EF6 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB09212023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 22.0 Project Name: Married Student Second Stake Test Location: Interior footing on west side of building Client: The Church of Jesus Christ of Latter-day Saints Admixtures: MP 322 Contractor: Alpha Concrete Supplier: Walters Ready Mix, Inc Mix Number: W170-F 35 Date: 8/24/2023 Cylinder Log #: 498 Set #: 1 Entrained Air (%): 1.8 Concrete Temperature (°F): 76 Ambient Temperature (°F): 99 Unit Weight (PCF): 146.0 Tested By: Leland Steiner Date: 8/24/2023 Picked Up By: L. Steiner Pick Up Date: 8/25/2023 Pick Up Time: 10:41 AM Max, Min Temperature: 70,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 8/31/2023 12.57 47570 3784 3000 Type 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. DD1D6409-2C8B-4187-90DC-425C09BC7EF6 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 9/21/2023 4.000 12.57 53565.0 4261 3000.0 Type 3 C 28 9/21/2023 4.000 12.57 56130.0 4465 3000.0 Type 3 D 28 9/21/2023 4.000 12.57 56780.0 4517 3000.0 Type 3 Second Break Average: 4414 Date: 09/22/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A46BE1FB-EBC2-4576-B746-DD5B8CB44140 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB09252023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 8.0 Project Name: Married Student Second Stake Test Location: Footings, north side of building Client: The Church of Jesus Christ of Latter-day Saints Admixtures: MP 322 Contractor: Alpha Concrete Construction Supplier: Walter's Ready Mix, Inc. Mix Number: W170-F 35 Date: 8/28/2023 Cylinder Log #: 504 Set #: 1 Entrained Air (%): 1.2 Concrete Temperature (°F): 77 Ambient Temperature (°F): 80 Unit Weight (PCF): 148.6 Tested By: Michael Hammar Date: 8/28/2023 Picked Up By: L. Steiner Pick Up Date: 8/29/2023 Pick Up Time: 4:17 PM Max, Min Temperature: 77,60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/4/2023 12.57 44460 3537 3000 Type 6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A46BE1FB-EBC2-4576-B746-DD5B8CB44140 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 9/25/2023 4.000 12.57 56180.0 4469 3000.0 Type 3 C 28 9/25/2023 4.000 12.57 54750.0 4356 3000.0 Type 6 D 28 9/25/2023 4.000 12.57 55350.0 4403 3000.0 Type 6 Second Break Average: 4409 Date: 09/28/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 72452B4E-FA8D-4270-AEC6-68F7FDEBB5E5 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB10042023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 33.0 Project Name: Married Student Second Stake Test Location: Interior subfloor Client: The Church of Jesus Christ of Latter-day Saints Admixtures: MP 322 Contractor: Alpha Concrete Supplier: Walters Ready Mix, Inc Mix Number: 170-3500 Date: 9/6/2023 Cylinder Log #: 523 Set #: 2 Entrained Air (%): 1.1 Concrete Temperature (°F): 67 Ambient Temperature (°F): 41 Unit Weight (PCF): 148.3 Tested By: Leland Steiner Date: 9/6/2023 Picked Up By: Matthew Hammar Pick Up Date: 9/7/2023 Pick Up Time: 11:01 AM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/13/2023 12.57 60895 4844 3500 Type 6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 72452B4E-FA8D-4270-AEC6-68F7FDEBB5E5 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/4/2023 4.000 12.57 71630.0 5698 3500.0 Type 2 C 28 10/4/2023 4.000 12.57 73265.0 5829 3500.0 Type 3 D 28 10/4/2023 4.000 12.57 72290.0 5751 3500.0 Type 3 Second Break Average: 5759 Date: 10/05/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A8491DD5-3D79-4659-A935-18BD5850DD43 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB10062023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 66 Project Name: Married Student Second Stake Test Location: But. Slab on grade Client: The Church of Jesus Christ of Latter-day Saints Admixtures: N/A Contractor: Headwaters Construction Supplier: Walters Mix Number: 170-3500 Date: 9/8/2023 Cylinder Log #: 535 Set #: 2 Entrained Air (%): 1.5 Concrete Temperature (°F): 72 Ambient Temperature (°F): 69 Unit Weight (PCF): 148.2 Tested By: Bryton Ferguson Date: 9/8/2023 Picked Up By: Matthew Hammar Pick Up Date: 9/9/2023 Pick Up Time: 12:46 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/15/2023 12.57 61320 4878 3,500.00 Type 3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A8491DD5-3D79-4659-A935-18BD5850DD43 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/6/2023 4.000 12.57 71,890.0 5719 3,500.0 Type 1 C 28 10/6/2023 4.000 12.57 72,105.0 5736 3,500.0 Type 1 D 28 10/6/2023 4.000 12.57 72,475.0 5766 3,500.0 Type 3 Second Break Average: 5740 Date: 10/09/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A8491DD5-3D79-4659-A935-18BD5850DD43 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB10062023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 66 Project Name: Married Student Second Stake Test Location: But. Slab on grade Client: The Church of Jesus Christ of Latter-day Saints Admixtures: N/A Contractor: Headwaters Construction Supplier: Walters Mix Number: 170-3500 Date: 9/8/2023 Cylinder Log #: 535 Set #: 2 Entrained Air (%): 1.5 Concrete Temperature (°F): 72 Ambient Temperature (°F): 69 Unit Weight (PCF): 148.2 Tested By: Bryton Ferguson Date: 9/8/2023 Picked Up By: Matthew Hammar Pick Up Date: 9/9/2023 Pick Up Time: 12:46 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/15/2023 12.57 61320 4878 3,500.00 Type 3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A8491DD5-3D79-4659-A935-18BD5850DD43 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/6/2023 4.000 12.57 71,890.0 5719 3,500.0 Type 1 C 28 10/6/2023 4.000 12.57 72,105.0 5736 3,500.0 Type 1 D 28 10/6/2023 4.000 12.57 72,475.0 5766 3,500.0 Type 3 Second Break Average: 5740 Date: 10/09/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A8491DD5-3D79-4659-A935-18BD5850DD43 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB10062023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 66 Project Name: Married Student Second Stake Test Location: But. Slab on grade Client: The Church of Jesus Christ of Latter-day Saints Admixtures: N/A Contractor: Headwaters Construction Supplier: Walters Mix Number: 170-3500 Date: 9/8/2023 Cylinder Log #: 535 Set #: 2 Entrained Air (%): 1.5 Concrete Temperature (°F): 72 Ambient Temperature (°F): 69 Unit Weight (PCF): 148.2 Tested By: Bryton Ferguson Date: 9/8/2023 Picked Up By: Matthew Hammar Pick Up Date: 9/9/2023 Pick Up Time: 12:46 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/15/2023 12.57 61320 4878 3,500.00 Type 3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. A8491DD5-3D79-4659-A935-18BD5850DD43 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/6/2023 4.000 12.57 71,890.0 5719 3,500.0 Type 1 C 28 10/6/2023 4.000 12.57 72,105.0 5736 3,500.0 Type 1 D 28 10/6/2023 4.000 12.57 72,475.0 5766 3,500.0 Type 3 Second Break Average: 5740 Date: 10/09/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9973F820-9B3B-4C1E-838C-9ED81E03FC72 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB10102023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 65 Project Name: Married Student Second Stake Test Location: Slab on grade: A-B:1-2 Client: The Church of Jesus Christ of Latter-day Saints Admixtures: MP 322 Contractor: Headwaters Supplier: Walters Mix Number: 170-3500 Date: 9/12/2023 Cylinder Log #: 550 Set #: 2 Entrained Air (%): 1.5 Concrete Temperature (°F): 69 Ambient Temperature (°F): 68 Unit Weight (PCF): 146.6 Tested By: Bryton Ferguson Date: 9/12/2023 Picked Up By: Matthew Hammar Pick Up Date: 9/13/2023 Pick Up Time: 1:26 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/19/2023 12.57 56275 4477 3500 Type 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9973F820-9B3B-4C1E-838C-9ED81E03FC72 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/10/2023 4.000 12.57 69,455.0 5525 3,500.0 Type 1 C 28 10/10/2023 4.000 12.57 68,910.0 5482 3,500.0 Type 1 D 28 10/10/2023 4.000 12.57 69,080.0 5496 3,500.0 Type 1 Second Break Average: 5501 Date: 10/14/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9973F820-9B3B-4C1E-838C-9ED81E03FC72 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB10102023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 65 Project Name: Married Student Second Stake Test Location: Slab on grade: A-B:1-2 Client: The Church of Jesus Christ of Latter-day Saints Admixtures: MP 322 Contractor: Headwaters Supplier: Walters Mix Number: 170-3500 Date: 9/12/2023 Cylinder Log #: 550 Set #: 2 Entrained Air (%): 1.5 Concrete Temperature (°F): 69 Ambient Temperature (°F): 68 Unit Weight (PCF): 146.6 Tested By: Bryton Ferguson Date: 9/12/2023 Picked Up By: Matthew Hammar Pick Up Date: 9/13/2023 Pick Up Time: 1:26 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/19/2023 12.57 56275 4477 3500 Type 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 9973F820-9B3B-4C1E-838C-9ED81E03FC72 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/10/2023 4.000 12.57 69,455.0 5525 3,500.0 Type 1 C 28 10/10/2023 4.000 12.57 68,910.0 5482 3,500.0 Type 1 D 28 10/10/2023 4.000 12.57 69,080.0 5496 3,500.0 Type 1 Second Break Average: 5501 Date: 10/14/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. CEB2FAAB-73CE-45BC-97DF-2245EE977927 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB10102023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 11 Project Name: Married Student Second Stake Test Location: Slab on grade: A-B:1-2 Client: The Church of Jesus Christ of Latter-day Saints Admixtures: MP 322 Contractor: Headwaters Supplier: Walters Mix Number: 170-3500 Date: 9/12/2023 Cylinder Log #: 549 Set #: 1 Entrained Air (%): 1.5 Concrete Temperature (°F): 73 Ambient Temperature (°F): 65 Unit Weight (PCF): 148.3 Tested By: Bryton Ferguson Date: 9/12/2023 Picked Up By: Matthew Hammar Pick Up Date: 9/13/2023 Pick Up Time: 1:12 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/19/2023 12.57 55900 4447 3500 Type 6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. CEB2FAAB-73CE-45BC-97DF-2245EE977927 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/10/2023 4.000 12.57 62,880.0 5002 3,500.0 Type 1 C 28 10/10/2023 4.000 12.57 67,285.0 5353 3,500.0 Type 3 D 28 10/10/2023 4.000 12.57 68,430.0 5444 3,500.0 Type 1 Second Break Average: 5266 Date: 10/14/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. FB16B15A-53EA-456E-B576-681B76ADF7E8 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB10122023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 11.0 Project Name: Married Student Second Stake Test Location: Referencing plans page S103. 11.5 - A6 Client: The Church of Jesus Christ of Latter-day Saints Admixtures: MP322 Contractor: ALPHA CONCRETE CONSTRUCTION Supplier: WALTERS READY MIX INC. Mix Number: 170-3500 Date: 9/14/2023 Cylinder Log #: 558 Set #: 1 Entrained Air (%): 2.0 Concrete Temperature (°F): 69 Ambient Temperature (°F): 42 Unit Weight (PCF): 147 Tested By: Matthew Hammar Date: 9/14/2023 Picked Up By: Matthew Hammar Pick Up Date: 9/15/2023 Pick Up Time: 5:39 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/21/2023 12.57 0 3500 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. FB16B15A-53EA-456E-B576-681B76ADF7E8 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/12/2023 4.000 12.57 69,135.0 5500 3,500.0 Type 3 C 28 10/12/2023 4.000 12.57 68,290.0 5433 3,500.0 Type 3 D 28 10/12/2023 4.000 12.57 68,365.0 5439 3,500.0 Type 1 Second Break Average: 5457 Date: 10/14/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7926E6CB-76E1-44F8-8A21-60922D7B5046 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB10122023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 66 Project Name: Married Student Second Stake Test Location: Referencing plans page S103. 8.5 - A6 Client: The Church of Jesus Christ of Latter-day Saints Admixtures: MP322 Contractor: ALPHA CONCRETE CONSTRUCTION Supplier: WALTERS READY MIX INC. Mix Number: 170-3500 Date: 9/14/2023 Cylinder Log #: 559 Set #: 2 Entrained Air (%): 2.0 Concrete Temperature (°F): 67 Ambient Temperature (°F): 45 Unit Weight (PCF): 147.4 Tested By: Matthew Hammar Date: 9/14/2023 Picked Up By: Matthew Hammar Pick Up Date: 9/15/2023 Pick Up Time: 5:45 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/21/2023 12.57 58330 4640 3500 Type 6 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 7926E6CB-76E1-44F8-8A21-60922D7B5046 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/12/2023 4.000 12.57 71,470.0 5686 3,500.0 Type 3 C 28 10/12/2023 4.000 12.57 71,670.0 5702 3,500.0 Type 3 D 28 10/12/2023 4.000 12.57 71,395.0 5680 3,500.0 Type 3 Second Break Average: 5689 Date: 10/14/2023 Reviewed By: Luke Hammar Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. CA3BC67C-D617-49A3-9933-DF527CD78E21 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB10172023EV Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 11.0 Project Name: Married Student Second Stake Test Location: Gridlines: 1.5-2:A-B. Reference plans Pg. S101 Client: The Church of Jesus Christ of Latter-day Saints Admixtures: Plasticizer Contractor: Headwaters Construction Supplier: Walters Ready Mix, Inc. Mix Number: 170-3500 Date: 9/19/2023 Cylinder Log #: 578 Set #: 1 Entrained Air (%): 2.0 Concrete Temperature (°F): 70 Ambient Temperature (°F): 55 Unit Weight (PCF): 146.6 Tested By: Bryton Ferguson Date: 9/19/2023 Picked Up By: Matthew Hammar Pick Up Date: 9/20/2023 Pick Up Time: 1:07 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 9/26/2023 12.57 62010 4933 3,500.00 Type 3 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. CA3BC67C-D617-49A3-9933-DF527CD78E21 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 10/17/2023 4.000 12.57 71,550.0 5692 3,500.0 Type 1 C 28 10/17/2023 4.000 12.57 73,650.0 5859 3,500.0 Type 2 D 28 10/17/2023 4.000 12.57 71,605.0 5696 3,500.0 Type 2 Second Break Average: 5749 Date: 10/18/2023 Reviewed By: E. Vail Signature: PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 805F104C-0EF3-41C2-AAE2-87808A8857F5 1 4103 E 605 N Suite 1 Rigby, ID 83442 208.932.4428 File name: 23255SB11092023MDH Compressive Strength of Concrete Test Specimens Project Number: 23-255 Cumulative Test Load Amount: 10 Project Name: Married Student Second Stake Test Location: Dumpster enclosure approximately south west corner of parking lot Client: The Church of Jesus Christ of Latter-day Saints Admixtures: HP 322, MA AE 90 Contractor: Alpha Supplier: Walters Mix Number: 4500-AF Date: 10/12/2023 Cylinder Log #: 649 Set #: 1 Entrained Air (%): 5.5 Concrete Temperature (°F): 63 Ambient Temperature (°F): 46 Unit Weight (PCF): 138.5 Tested By: Bryton Ferguson Date: 10/12/2023 Picked Up By: Matthew Hammar Pick Up Date: 10/13/2023 Pick Up Time: 4:41 PM Max, Min Temperature: 80, 60 Compressive Strength Data Previous Test Results: Cylinder ID:Break Age:Break Date:Area (in^2):Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: A 7 10/19/2023 12.57 47495 3778 3,000.00 Type 1 PRIVILEGED AND CONFIDENTIAL: This document and the information contained herein are confidential and protected from disclosure. This message and its content is intended only for the use of the addressee(s) and may contain sensitive, confidential information. If you are not the intended recipient, you are hereby notified that the use, dissemination, or copying of this information is strictly prohibited, please notify the sender immediately. 805F104C-0EF3-41C2-AAE2-87808A8857F5 2 Current Break Testing: Cylinder ID: Break Age: Break Date: Diameter (in): Area (in^2): Maximum Load (lbs): Compressive Strength (psi): Required 28 day Strength (psi): Break Type: B 28 11/9/2023 4.000 12.57 61,700.0 4909 3,000.0 Type 3 C 28 11/9/2023 4.000 12.57 55,500.0 4415 3,000.0 Type 1 D 28 11/9/2023 4.000 12.57 63,490.0 5051 3,000.0 Type 3 Second Break Average: 4792 Date: 11/13/2023 Reviewed By: Luke Hammar Signature: