Loading...
HomeMy WebLinkAboutTRUSS CONSTRUCTION SET - 23-00170 - Rexburg 10th Ward LDS MeetinghouseF02 (6) F0 1 F0 1 13'- 0" 11 ' - 0 " General Notes: 1. TCLL-TCDL-BCLL-BCDL: 25-10-0-10 (UNO). 2. Roof Slope: 5/12, Heel: 0-7-8, Tails: 2x4 (TYP). 3. 24" o.c. spacing (UNO). 4. Dimensions to outside of framing (UNO). 5. Trusses may be shifted in field as req'd without exceeding max tributary area. Storage Bldg. 5 5 P.O. Box 5787 17900 SE Wallace Rd Dayton, OR 97114 Tel: (503) 581-8787 Fax: (503) 399-8787 Re x b u r g 1 0 - W a r d L D S C h a p e l 41 1 U n i v e r s i t y B o u l e v a r d Re x b u r g Project Number: 2305309HWC Customer: Headwaters Constructi... Designer: Michael Jackson Salesperson ID: Yash Sakharkar Revision 1: Date: 07 / 11 / 23 THIS IS A TRUSS PLACEMENT DIAGRAM ONLY These trusses are designed as individual building components to be incorporated into the building design at the specification of the building designer. See individual design sheets for each truss design identified on the placement drawing. The building designer is responsible for temporary and permanent bracing of the roof and floor system and for the overall structure. The design of the entire truss support structure including, but not limited to headers, beams, walls, and columns is the responsibility of the building designer. For general guidance regarding bracing, consult ''Bracing of wood trusses'' available from the Truss Plate Institute, 218 N. Lee Street, Ste. 312, Alexandria, VA 22314. B06 (11) B06 (12) BK4 (54)BK4 (17)BK4 (8)BK4 (14) BK4 (54)BK4 (42) BK 1 ( 1 4 ) BK 1 ( 2 1 ) BK 1 ( 1 4 ) BK1 (18)BK1 (32)BK1 (8)BK1 (14)BK1 (18) BK1 (53)BK1 (16)BK1 (5)BK1 (18) E01 (66)E01 (45) PB1 (61)PB1 (44) D02 (2) D02 (2) B02 (7)B02 (8) B02 (7)B02 (7) A0 1 ( 1 8 ) A0 2 ( 2 ) A0 2 ( 2 ) B05 (2) B05 (2) B04 (40) B04 (35)B04 (5) B01 (19)B01 (14)B01 (6) B01 (25)B01 (7)B01 (6) C0 3 ( 8 ) C0 3 ( 8 ) C0 2 ( 2 ) C0 2 ( 2 ) GD R 3 GD R 3 GD R 2 C01 4'- 0" 4'- 0" GD R 4 D0 1 D0 2 GD R 5 D0 1 D0 2GDR6J26 J25 J24 J23 J22 J21 J20 J12 J11 J10 J09 J08 J07 J06 J05 J04 J03 J02 J01 J0 2 J0 1 J1 2 J1 1 J1 0 J0 9 J0 8 J0 7 J0 6 J0 5 J0 4 J0 3 J1 3 J1 4 J1 5 J1 6 J1 7 J1 8 J1 9 GD R 7 J03 J02 J0 1GDR6J26 J25 J24 J23 J22 J21 J20 J12 J11 J10 J09 J08 J07 J06 J05 J04 J01 J0 2 J1 2 J1 1 J1 0 J0 9 J0 8 J0 7 J0 6 J0 5 J0 4 J0 3 J1 3 J1 4 GD R 7 J1 5 J1 6 J1 7 J1 8 J1 9 4'- 0"4'- 0" D0 1 D 0 1 1' - 9 1 / 4 " 1'- 9 1/4" 24 " o . c . 24" o.c. 1' - 9 1 / 4 " 1'- 9 1/4" 24 " o . c . 24" o.c. C01 BK2 BK2 BK3 BK4 BK3 BK4 E0 2 P B 2 38'- 8 3/4"24" o.c. PB 3 PB 3 4'- 4" 2'- 0 3/4"2'- 0 3/4" 27'- 10"12'- 2"51'- 9 1/2"12'- 2"60'- 11 5/8"30'- 10"55'- 1 1/8" 3' - 0 7 / 1 6 " 2' - 6 1 / 2 " PB 4 55'- 5"30'- 10"74'- 1 1/4"12'- 2"27'- 10"12'- 2"38'- 4" 26 ' - 6 " 15 ' - 8 " 6' - 4 " 24 ' - 8 " 6' - 4 " 15 ' - 8 " 26 ' - 6 " 26 ' - 6 " 15 ' - 8 " 37 ' - 4 " 15 ' - 8 " 26 ' - 6 " 43 ' - 4 " General Notes: 1. TCLL-TCDL-BCLL-BCDL: 25-10-0-10 (UNO). 2. Roof Slope: 4.5/12, Heel: 1-8-13, Tails: 2x6 (TYP). 3. 24" o.c. spacing (UNO). 4. Dimensions to outside of framing (UNO). 5. Trusses may be shifted in field as req'd without exceeding max tributary area. GDR1 6' - 0 " 24 " o . c . GDR1 6' - 0 " Use Truss TR9 for perlin framing. Cut truss as required in field. Fasteners Key Model Qty Top Face Supported A MUS26 3 6-10d 6-10d B SUL26 12 C SUR26 12 D THA29 7 4-10d 6-10d 4-10d E THASL29 10 F THASR29 10 A A D D D A D D D C C C C C C C C C C C C B B B B B B B B B B B B F F F F F F E E E E E E F F E E F F E E D 4.5 4.5 4. 5 4. 5 0 4. 5 4. 5 4 4. 5 4. 5 4. 5 4. 5 4.5 4.5 4.5 4. 5 4. 5 4.5 4.5 4.5 4. 5 4. 5 4.5 4.5 4.5 4.5 4. 5 4. 5 2.5 2.5 0 P.O. Box 5787 17900 SE Wallace Rd Dayton, OR 97114 Tel: (503) 581-8787 Fax: (503) 399-8787 Re x b u r g 1 0 - W a r d L D S C h a p e l 41 1 U n i v e r s i t y B o u l e v a r d Re x b u r g Project Number: 2305309HWC Customer: Headwaters Construction Co Designer: Michael Jackson Salesperson ID: Yash Sakharkar Revision 1: Date: 08 / 29 / 23 THIS IS A TRUSS PLACEMENT DIAGRAM ONLY These trusses are designed as individual building components to be incorporated into the building design at the specification of the building designer. See individual design sheets for each truss design identified on the placement drawing. The building designer is responsible for temporary and permanent bracing of the roof and floor system and for the overall structure. The design of the entire truss support structure including, but not limited to headers, beams, walls, and columns is the responsibility of the building designer. For general guidance regarding bracing, consult ''Bracing of wood trusses'' available from the Truss Plate Institute, 218 N. Lee Street, Ste. 312, Alexandria, VA 22314. Prepared for: Job: Date: Ref. Number: Oregon Truss 2305309HWC - Rexburg 10-Ward LDS Chapel 8/7/2023 11:39 AM 199573 COMPONENT DESIGN DRAWINGS & DETAILS Simpson Strong-Tie Company, Inc. 5956 W. Las Positas Blvd. Pleasanton, CA 94588 (800) 999-5099 www.strongtie.com Notes: 1. The component design drawings referenced below have been prepared based on design criteria and requirements set forth in the Construction Documents, as communicated by the Component Manufacturer. 2. The engineer's signature on these drawings indicates professional engineering responsibility solely for the individual components to be able to resist the design loads indicated, utilizing all the design parameter and materials indicated or referenced on each individual design. 3. It is the Building Designer's responsibility to review the component design drawings to insure compatibility with the Building design, Refer to all notes on the individual component design drawings. 58 Component Design Drawing(s): 1 1-A01: SID 2341917 16-D02: SID 2341932 31-J04: SID 2341947 46-J19: SID 2341962 2 2-A02: SID 2341918 17-E01: SID 2341933 32-J05: SID 2341948 47-J20: SID 2341963 3 3-B01: SID 2341919 18-E02: SID 2341934 33-J06: SID 2341949 48-J21: SID 2341964 4 4-B02: SID 2341920 19-F01: SID 2341935 34-J07: SID 2341950 49-J22: SID 2341965 5 5-B04: SID 2341921 20-F02: SID 2341936 35-J08: SID 2341951 50-J23: SID 2341966 6 6-B05: SID 2341922 21-GDR1: SID 2341937 36-J09: SID 2341952 51-J24: SID 2341967 7 7-B06: SID 2341923 22-GDR2: SID 2341938 37-J10: SID 2341953 52-J25: SID 2341968 8 8-BK1: SID 2341924 23-GDR3: SID 2341939 38-J11: SID 2341954 53-J26: SID 2341969 9 9-BK2: SID 2341925 24-GDR4: SID 2341940 39-J12: SID 2341955 54-PB1: SID 2341970 10 10-BK3: SID 2341926 25-GDR5: SID 2341941 40-J13: SID 2341956 55-PB2: SID 2341971 11 11-BK4: SID 2341927 26-GDR6: SID 2341942 41-J14: SID 2341957 56-PB3: SID 2341972 12 12-C01: SID 2341928 27-GDR7: SID 2341943 42-J15: SID 2341958 57-PB4: SID 2341973 13 13-C02: SID 2341929 28-J01: SID 2341944 43-J16: SID 2341959 58-TR 9: SID 2341974 14 14-C03: SID 2341930 29-J02: SID 2341945 44-J17: SID 2341960 15 15-D01: SID 2341931 30-J03: SID 2341946 45-J18: SID 2341961 General Notes 1. Each Truss Design Drawing (TDD) provided with this sheet has been prepared in conformance with ANSI/TPI 1. Refer to ANSI/TPI 1 Chapter 2 for the responsibilities of all parties involved, which include but are not limited to the responsibilities listed on this sheet, and for the definitions of all capitalized terms referenced in this document. 2. TDDs should not be assumed to be to scale. 3. The Contractor and Building Designer shall review and approve the Truss Submittal Package. 4. The suitability and use of the component depicted on the TDD for any particular building design is the responsibility of the Building Designer. 5. The Building Designer is responsible for the anchorage of the truss at all bearing locations as required to resist uplift, gravity and lateral loads, and for all Truss-to-Structural Element connections except Truss-to-Truss connections. 6. The Building Designer shall ensure that the supporting structure can accommodate the vertical and/or horizontal truss deflections. 7. Unless specifically stated otherwise, each Design assumes trusses will be adequately protected from the environment and will not be used in corrosive environments unless protected using an approved method. This includes not being used in locations where the sustained temperature is greater than 150°F. 8. Trusses are designed to carry loads within their plane. Any out-of- plane loads must be resisted by the Permanent Building Stability Bracing. 9. Design dead loads must account for all materials, including self-weight. The TDD notes will indicate the min. pitch above which the dead loads are automatically increased for pitch effects. 10. Trusses installed with roof slopes less than 0.25/12 may experience (but are not designed for) ponding. The Building Designer must ensure that adequate drainage is provided to prevent ponding. 11. Camber is a non-structural consideration and is the responsibility of truss fabricator. Handling, Installing, Restraint & Bracing 1. The Contractor is responsible for the proper handling, erection, restraint and bracing of the Trusses. In lieu of job-specific details, refer to BCSI. 2. ANSI/TPI 1 stipulates that for trusses spanning 60' or greater, the Owner shall contract with any Registered Design Professional for the design and inspection of the temporary and permanent truss restraint and bracing. Simpson Strong-Tie is not responsible for providing these services. 3. Trusses require permanent lateral restraint to be applied to chords and certain web members (when indicated) at the locations or intervals indicated on the TDD. Web restraints are to be located at mid points, or third points of the member and chord purlins are not to exceed the spacing specified by the TDD. Chords shown without bracing indicated are assumed to be continuously braced by sheathing or drywall. Permanent lateral restraint shall be accomplished in accordance with: standard industry lateral restraint/bracing details in BCSI-B3 or BCSI-B7, supplemental bracing details referenced on the TDD, or as specified in a project-specific truss permanent bracing plan provided by the Building Designer. 4. Additional building stability permanent bracing shall be installed as specified in the Construction Documents. 5. Special end wall bracing design considerations may be required if a flat gable end frame is used with adjacent trusses that have sloped bottom chords (see BCSI-B3). 6. Do not cut, drill, trim, or otherwise alter truss members or plates without prior written approval of an engineer, unless specifically noted on the TDD. 7. Piggyback assemblies shall be braced as per BCSI-B3 unless otherwise specified in the Construction Documents. 8. For floor trusses, when specified, Strongbacking shall be installed per BCSI-B7 unless otherwise specified in the Construction Documents. 9. For IBC 2021 and newer, truss chords without a diaphragm require a project specific bracing design prepared by a registered design professional. Symbols and Nomenclature 5x7 Plate size; the first digit is the plate width (perp. to the slots) and the second digit is the plate length (parallel to the slots). 5x7-18 -18, -18S5, or -18S6 following the plate size indicates different 18 gauge plate types. These symbols following the plate size indicate the direction of the plate length (and tooth slots) for square and nearly square plates. 10-3-14 Dimensions are shown in feet-inches-sixteenths (for this example, the dimension is 10'-3 14/16"). Joints are numbered left to right, first along the top chord and then along the bottom chord. Mid-panel splice joint numbers are not shown on the drawing. Members are identified using their end joint numbers (e.g., TC 2-3). When this symbol is shown, permanent lateral restraint is required. Lateral restraint may be applied to either edge of the member. See Note 3 under Handling, Installing, Restraint & Bracing for more information. Bearing supports (wall, beam, etc.), locations at which the truss is required to have full bearing. Minimum required bearing width for the given reactions are reported on the TDD. Required bearing widths are based on the truss material and indicated PSI of the support material. The Building Designer is responsible for verifying that the capacity of the support material exceeds the indicated PSI, and for all other bearing design considerations. Truss-to-Truss or Truss-to-Structural Element connection, which require a hanger or other structural connection (e.g., toe-nail) that has adequate capacity to resist the maximum reactions specified in the Reaction Summary. Structural connection type is not limited by type shown on TDD. Toe- nails may be used where hanger type shown where allowed by detail or other connection design information. Design of the Structural Element and the connection of the Truss to a Structural Element is by others. Note: These symbols are for graphical interpretation only; they are not intended to give any indication of the geometry requirements of the actual item that is represented. Materials and Fabrication 1. Design assumes truss is manufactured in accordance with the TDD and the quality criteria in ANSI/TPI 1 Chapter 3, unless more restrictive criteria are part of the contract specifications. 2. Unless specifically stated, lumber shall not exceed 19% moisture content at time of fabrication or in service. 3. Design is not applicable for use with fire retardant, preservative treated or green lumber unless specifically stated on the TDD. 4. Plate type, size, orientation and location indicated are based on the specified design parameters. Larger plate sizes may be substituted in accordance with ANSI/TPI, Section 3.6.3. Plates shall be embedded within ANSI/TPI 1 tolerances on both faces of the truss at each joint, unless noted otherwise. 5. Truss plates shall be centered on the joint unless otherwise specified. Referenced Standards ANSI/TPI 1: National Design Standard for Metal Plate Connected Wood Truss Construction, a Truss Plate Institute publication (www.tpinst.org). BCSI: Guide to Good Practice for Handling, Installing, Restraining & Bracing Metal Plate Connected Wood Trusses, a joint publication of the Truss Plate Institute (www.tpinst.org ) and the Structural Building Components Association (www.sbcindustry.com ). DSB-89 Recommended Design Specification for Temporary Bracing of Metal Plate Connected Wood Trusses, a Truss Plate Institute publication (www.tpinst.org ). NDS: National Design Specification for Wood Construction published by American Forest & Paper Association and American Wood Council. ESR-2762 Simpson Strong-Tie® AS Truss Plates are covered under ESR-2762 published by the International Code Council Evaluation Service (www.icc-es.org ). TD-GEN-0003A 5/2019 Component SolutionsŒImportant Information & General Notes EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 18 Truss: A01 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341917 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x10 4x4 = 5x6 = 5x5 = 6x10-18 2x4 5x16 4x5 =2x42x4 2x4 4x5 = 6x10 4x4 = 5x8-18 5x6 = 8x12 6x12 2x4 1-6-0 14 - 4 - 4 1- 8 - 1 3 1- 1 0 - 1 4 16 - 3 - 2 1 7-2-13 7-2-13 2 7-2-13 14-5-9 3 7-2-13 21-8-6 5 7-3-12 29-0-2 6 4-2-4 33-2-6 7 4-4-2 37-6-8 9 1-2-4 38-8-12 10 11 7-2-13 7-2-13 13 7-2-13 14-5-9 14 7-2-13 21-8-6 16 7-3-12 29-0-2 17 8-6-6 37-6-8 18 1-2-4 38-8-12 19 4 8 12 15 38-8-12 10-1010-10 4.5/12 4.5/12 Truss Weight = 285.2 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-13 5-17 2x4 DFL #2 2-14 3-16 Member Forces Summary Max CSI in TC PANEL 2 - 3 0.96 Max CSI in BC PANEL 17 - 18 0.99 Max CSI in Web 7 - 18 0.89 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 1217 5799 0.84 2- 3 1258 6625 0.96 3- 4 463 3078 0.41 4- 5 482 2984 0.44 5- 6 4861 1126 0.82 6- 7 4761 1019 0.80 7- 8 23 92 0.12 8- 9 60 62 0.11 9-10 40 68 0.07 10-OH 0 12 0.00 BC OH-11 4 0 0.00 11-12 295 703 0.15 12-13 333 696 0.22 13-14 5709 1787 0.67 14-15 6509 1682 0.73 15-16 6520 1658 0.67 16-17 3013 812 0.52 17-18 385 2193 0.99 18-19 21 51 0.07 19-OH 1 9 0.00 Web 1-11 479 1557 0.19 1-13 5407 1036 0.47 2-13 311 923 0.11 2-14 802 50 0.15 3-14 196 39 0.08 3-16 844 3359 0.82 5-16 725 65 0.32 5-17 1612 7294 0.79 6-17 261 832 0.10 7-17 655 3020 0.49 7-18 2032 340 0.89 9-18 227 433 0.07 10-19 67 122 0.03 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 11 01-12 1646 0 05-08 01-12 DFL 625 17 29-00-02 3393 232 05-14 02-14 DFL 781 18 37-06-08 192 444 07-12 01-08 DFL 625 Max Horiz = -22 / +420 at Joint 11 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [38-08-12] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/496(-0.70) 13-14 Vert DL L/120 L/995(-0.35) 13-14 Vert CR L/240 L/331(-1.05) 13-14 Horz LL 0.75in ( 0.07) @Jt17 Horz CR 1.25in ( 0.10) @Jt17 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-04-00 -1-06-00 38-08-12 13 BC 6-03-00 0 38-08-12 7 ------- Web Bracing -- CLR ----------- Single: 3-16 5-17 17- 7 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(01-08,0), Jnt5(01-03,00-07), Jnt13(-01-03,-00-07), Jnt18(-01-13,-01-10) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: A02 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341918 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x10 4x4 = 5x6 = 5x5 = 6x10-18 2x4 5x16 4x5 =2x4 2x4 2x4 4x5 = 6x10 4x4 = 5x8-18 5x6 = 8x12 6x12 2x4 14 - 4 - 4 1- 8 - 1 3 1- 1 0 - 1 4 16 - 3 - 2 1 7-2-13 7-2-13 2 7-2-13 14-5-9 3 7-2-13 21-8-6 5 7-3-12 29-0-2 6 4-2-4 33-2-6 7 4-4-2 37-6-8 9 1-2-4 38-8-12 10 11 7-2-13 7-2-13 13 7-2-13 14-5-9 14 7-2-13 21-8-6 16 7-3-12 29-0-2 17 8-6-6 37-6-8 18 1-2-4 38-8-12 19 4 8 12 15 38-8-12 10-1010-10 4.5/12 4.5/12 Truss Weight = 282.0 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-13 5-17 2x4 DFL #2 2-14 3-16 Member Forces Summary Max CSI in TC PANEL 2 - 3 0.96 Max CSI in BC PANEL 17 - 18 1.00 Max CSI in Web 7 - 18 0.90 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 1333 5818 0.86 2- 3 1327 6633 0.96 3- 4 480 3079 0.44 4- 5 493 2932 0.39 5- 6 4867 1172 0.82 6- 7 4767 1064 0.80 7- 8 41 92 0.12 8- 9 60 57 0.08 9-10 40 68 0.07 10-OH 0 12 0.00 BC OH-11 4 0 0.00 11-12 283 681 0.15 12-13 321 674 0.22 13-14 5729 1918 0.67 14-15 6517 1749 0.73 15-16 6528 1726 0.67 16-17 3015 811 0.52 17-18 411 2197 1.00 18-19 21 51 0.07 19-OH 1 9 0.00 Web 1-11 402 1394 0.17 1-13 5426 1189 0.47 2-13 343 928 0.11 2-14 750 62 0.14 3-14 198 28 0.08 3-16 898 3365 0.82 5-16 726 75 0.32 5-17 1665 7301 0.79 6-17 261 832 0.10 7-17 678 3023 0.49 7-18 2035 364 0.90 9-18 227 433 0.07 10-19 67 122 0.03 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 11 01-12 1484 0 05-08 01-09 DFL 625 17 29-00-02 3396 232 05-14 02-14 DFL 781 18 37-06-08 191 445 07-12 01-08 DFL 625 Max Horiz = -30 / +405 at Joint 11 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [38-08-12] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/496(-0.70) 13-14 Vert DL L/120 L/990(-0.35) 13-14 Vert CR L/240 L/330(-1.05) 13-14 Horz LL 0.75in ( 0.07) @Jt17 Horz CR 1.25in ( 0.10) @Jt17 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-04-00 0 38-08-12 13 BC 6-03-00 0 38-08-12 7 ------- Web Bracing -- CLR ----------- Single: 3-16 5-17 17- 7 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(01-08,0), Jnt5(01-03,00-07), Jnt13(-01-03,-00-07), Jnt18(-01-13,-01-10) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 77 Truss: B01 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341919 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x10 4x4 = 5x6 = 5x5 = 6x10-18 2x4 4x74x5 =4x4 = 6x12 2x4 4x5 = 6x10 4x4 = 5x8-18 5x6 = 10x10 = 4x4 = 4x16 1-6-0 3-0-0 4- 6 - 7 14 - 5 - 7 1- 8 - 1 3 1- 1 0 - 1 4 17 - 9 - 5 1 7-3-9 7-3-9 2 7-3-9 14-7-2 3 7-3-9 21-10-11 5 7-4-9 29-3-4 6 3-4-1 32-7-5 7 3-2-7 35-9-12 9 3-11-8 39-9-4 10 11 7-3-9 7-3-9 13 7-3-9 14-7-2 14 7-3-9 21-10-11 16 7-4-9 29-3-4 17 4-9-14 34-1-2 18 4-10-14 39-0-0 19 9-4 39-9-4 4 8 12 15 39-9-4 4.5/12 4.5/12 Truss Weight = 318.0 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = No Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 2x6 DFL 2400/2.0 4-8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-13 5-17 2x4 DFL #2 2-14 3-16 BB 2x10 DFL SS Member Forces Summary Max CSI in TC PANEL 2 - 3 0.98 Max CSI in BC PANEL 17 - 18 0.97 Max CSI in Web 3 - 16 0.88 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 1339 5766 0.88 2- 3 1460 6459 0.98 3- 4 751 2736 0.38 4- 5 771 2647 0.32 5- 6 5520 1277 0.61 6- 7 5376 1169 0.60 7- 8 2402 1619 0.15 8- 9 2481 1615 0.28 9-10 1377 3045 0.12 10-OH 0 109 0.36 BC OH-11 4 0 0.00 11-12 328 808 0.16 12-13 364 799 0.22 13-14 5675 1854 0.67 14-15 6343 1710 0.71 15-16 6354 1686 0.64 16-17 2669 801 0.48 17-18 1817 3470 0.97 18-19 2557 1446 0.17 Web 1-11 499 1545 0.19 1-13 5376 1152 0.47 2-13 330 906 0.11 2-14 682 100 0.13 3-14 205 16 0.08 3-16 896 3542 0.88 5-16 763 65 0.33 5-17 1650 7579 0.84 6-17 260 881 0.10 7-17 431 2486 0.79 7-18 1120 151 0.49 9-18 356 1569 0.25 9-19 1076 136 0.47 10-19 876 432 0.38 BBK 10-19 330 299 0.79 10-19 276 392 0.77 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 11 01-12 1634 124 05-08 01-12 DFL 625 17 29-03-04 3477 229 05-14 02-15 DFL 781 19 39-05-10 299 330 07-04 01-08 DFL 625 Max Horiz = -11 / +484 at Joint 11 Max Horiz = -11 / +484 at Joint 19 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [39-09-04] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Lateral forces from the bearing wall, if applicable, have not been considered in the design of the web(s) extended down to a bearing below the bottom chord. This condition may require additional design considerations and must be approved by the Building Designer. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/503(-0.69) 13-14 Vert DL L/120 L/999(-0.35) 13-14 Vert CR L/240 L/334(-1.04) 13-14 Horz LL 0.75in ( 0.61) @Jt10 Horz CR 1.25in ( 0.64) @Jt10 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Ohng CR 2L/240 2L/999(-0.06) 10-10 DPL LL L/120 L/152(-0.38) 20-20 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-05-00 -1-06-00 42-09-04 14 BC 4-11-00 0 39-00-00 9 ------- Web Bracing -- CLR ----------- Single: 3-16 5-17 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(01-08,0), Jnt5(01-03,00-07), Jnt7(-00-06,-00-02), Jnt10(02-01,01-12), Jnt13(-01-03,-00-07), Jnt19(03-13,00-09) EngDrwg: 2021r5RGT_Eng 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 29 Truss: B02 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341920 TID:199573 Date:08 / 08 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x10 4x4 = 5x6 = 5x5 = 6x10-18 2x4 4x74x5 = 4x4 = 4x4 = 2x4 5x10 5x8-18 4x4 = 5x6 = 4x5 = 8x12 4x4 = 5x12 3-0-0 20 4- 6 - 7 14 - 5 - 7 1- 9 - 9 1- 1 0 - 1 5 17 - 8 - 1 1 7-2-4 7-2-4 2 7-2-4 14-4-8 3 7-2-4 21-6-12 5 7-3-4 28-10-0 6 3-4-8 32-2-8 7 3-7-3 35-9-11 9 3-6-5 39-4-0 10 11 7-2-4 7-2-4 12 7-2-4 14-4-8 14 7-2-4 21-6-12 15 7-3-4 28-10-0 17 5-2-8 34-0-8 18 5-3-8 39-4-0 19 4 8 13 16 39-4-0 4.5/12 4.5/12 Truss Weight = 304.9 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-12 5-17 2x4 DFL #2 2-14 3-15 2x10 2.0E Microllam LVL Truss Chord 20-10 Member Forces Summary Max CSI in TC PANEL 2 - 3 1.00 Max CSI in BC PANEL 17 - 18 0.97 Max CSI in Web 3 - 15 0.82 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 1412 5655 0.90 2- 3 1480 6377 1.00 3- 4 733 2799 0.42 4- 5 746 2649 0.37 5- 6 5192 1226 0.83 6- 7 5062 1122 0.81 7- 8 2028 1812 0.22 8- 9 2122 1808 0.23 9-10 1199 3182 0.43 10-OH 0 123 0.44 BC OH-11 4 0 0.00 11-12 349 913 0.21 12-13 5532 1818 0.62 13-14 5567 1809 0.65 14-15 6274 1733 0.70 15-16 2698 896 0.25 16-17 2734 888 0.48 17-18 1821 3166 0.97 18-19 2817 1221 0.19 Web 1-11 417 1370 0.16 1-12 5271 1265 0.46 2-12 358 907 0.11 2-14 661 93 0.12 3-14 201 14 0.08 3-15 895 3396 0.82 5-15 741 70 0.32 5-17 1642 7323 0.79 6-17 251 840 0.10 7-17 476 2460 0.80 7-18 1155 139 0.51 9-18 328 1412 0.23 9-19 1130 277 0.50 10-19 1448 671 0.54 19-20 486 326 0.52 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 11 01-12 1459 95 01-08 HGR DFL 625 17 28-10-00 3392 141 05-14 02-14 DFL 781 20 38-11-06 326 290 07-04 01-08 DFL 625 Max Horiz = -129 / +447 at Joint 11 Max Horiz = -129 / +447 at Joint 20 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [39-04-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Lateral forces from the bearing wall, if applicable, have not been considered in the design of the web(s) extended down to a bearing below the bottom chord. This condition may require additional design considerations and must be approved by the Building Designer. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/518(-0.66) 12-14 Vert DL L/120 L/999(-0.33) 12-14 Vert CR L/240 L/345(-1.00) 12-14 Horz LL 0.75in ( 0.61) @Jt17 Horz CR 1.25in ( 0.64) @Jt17 Ohng CR 2L/240 2L/926(-0.09) 10-10 DPL LL L/120 L/187(-0.31) 20-19 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-06-00 0 42-04-00 13 BC 5-02-00 0 38-06-12 8 ------- Web Bracing -- CLR ----------- Single: 3-15 5-17 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(01-08,0), Jnt5(01-03,00-07), Jnt12(-01-03,-00-07), Jnt19(00-10,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 80 Truss: B04 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341921 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x10 4x4 = 5x6 = 5x5 = 6x10-18 2x4 4x74x5 =4x4 = 6x12 2x4 4x5 = 6x10 4x4 = 5x8-18 5x6 = 10x10 = 4x4 = 4x16 1-6-0 3-0-0 4- 6 - 7 14 - 5 - 7 1- 8 - 1 3 1- 1 0 - 1 4 17 - 9 - 5 1 7-3-9 7-3-9 2 7-3-9 14-7-2 3 7-3-9 21-10-11 5 7-4-9 29-3-4 6 3-4-1 32-7-5 7 3-2-7 35-9-12 9 3-11-8 39-9-4 10 11 7-3-9 7-3-9 13 7-3-9 14-7-2 14 7-3-9 21-10-11 16 7-4-9 29-3-4 17 4-9-14 34-1-2 18 4-10-14 39-0-0 19 9-4 39-9-4 4 8 12 15 39-9-4 4.5/12 4.5/12 Truss Weight = 318.0 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = No Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 2x6 DFL 2400/2.0 4-8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-13 5-17 2x4 DFL #2 2-14 3-16 BB 2x10 DFL SS Member Forces Summary Max CSI in TC PANEL 2 - 3 0.98 Max CSI in BC PANEL 17 - 18 0.97 Max CSI in Web 3 - 16 0.88 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 1339 5766 0.88 2- 3 1459 6459 0.98 3- 4 751 2736 0.38 4- 5 771 2647 0.32 5- 6 5520 1276 0.61 6- 7 5376 1168 0.60 7- 8 2402 1614 0.15 8- 9 2481 1610 0.28 9-10 1377 3036 0.12 10-OH 0 109 0.36 BC OH-11 4 0 0.00 11-12 328 806 0.16 12-13 364 798 0.22 13-14 5675 1853 0.67 14-15 6343 1709 0.71 15-16 6354 1685 0.64 16-17 2669 799 0.48 17-18 1815 3470 0.97 18-19 2551 1446 0.17 Web 1-11 499 1545 0.19 1-13 5376 1152 0.47 2-13 330 906 0.11 2-14 682 100 0.13 3-14 205 16 0.08 3-16 896 3542 0.88 5-16 763 65 0.33 5-17 1650 7579 0.84 6-17 260 881 0.10 7-17 431 2486 0.79 7-18 1120 151 0.49 9-18 356 1569 0.25 9-19 1076 136 0.47 10-19 876 431 0.38 BBK 10-19 330 299 0.79 10-19 276 392 0.77 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 11 01-12 1634 124 05-08 01-12 DFL 625 17 29-03-04 3477 229 05-14 02-15 DFL 781 19 39-05-10 299 330 07-04 01-08 DFL 625 Max Horiz = -11 / +484 at Joint 11 Max Horiz = -11 / +484 at Joint 19 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [39-09-04] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Lateral forces from the bearing wall, if applicable, have not been considered in the design of the web(s) extended down to a bearing below the bottom chord. This condition may require additional design considerations and must be approved by the Building Designer. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/503(-0.69) 13-14 Vert DL L/120 L/999(-0.35) 13-14 Vert CR L/240 L/334(-1.04) 13-14 Horz LL 0.75in ( 0.61) @Jt10 Horz CR 1.25in ( 0.64) @Jt10 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Ohng CR 2L/240 2L/999(-0.06) 10-10 DPL LL L/120 L/152(-0.38) 20-20 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-05-00 -1-06-00 42-09-04 14 BC 4-11-00 0 39-00-00 9 ------- Web Bracing -- CLR ----------- Single: 3-16 5-17 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(01-08,0), Jnt5(01-03,00-07), Jnt7(-00-06,-00-02), Jnt10(02-01,01-12), Jnt13(-01-03,-00-07), Jnt19(03-13,00-09) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: B05 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341922 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 6x8 4x4 = 5x5 = 4x6 7x8-18 = 2x4 4x7 4x4 =4x5 =2x6 2x4 6x8 4x4 = 5x8-18 5x5 = 8x12 4x4 = 4x10 1-6-0 19 3- 7 - 5 13 - 6 - 5 1- 8 - 1 3 1- 1 0 - 1 4 15 - 7 - 1 4 1 6-9-1 6-9-1 2 6-9-1 13-6-2 3 6-9-1 20-3-3 5 6-10-1 27-1-4 6 3-3-7 30-4-117 3-4-6 33-9-2 8 3-4-6 37-1-810 11 6-9-1 6-9-1 12 6-9-1 13-6-2 13 6-9-1 20-3-3 15 6-10-1 27-1-4 16 4-11-10 32-0-14 17 5-0-10 37-1-8 18 4 9 14 37-1-8 4.5/12 4.5/12 Truss Weight = 272.9 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL #2 1-12 2x6 DFL 1800/1.8 5-16 2x8 DFL 2250/2.0 19-10 Member Forces Summary Max CSI in TC PANEL 2 - 3 0.99 Max CSI in BC PANEL 16 - 17 0.98 Max CSI in Web 1 - 12 0.87 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 1147 4879 0.85 2- 3 1254 5558 0.99 3- 4 633 2397 0.38 4- 5 646 2270 0.36 5- 6 4703 1104 0.74 6- 7 4584 1003 0.72 7- 8 1713 1142 0.20 8- 9 836 2241 0.08 9-10 846 2234 0.07 10-OH 0 12 0.00 BC OH-11 4 0 0.00 11-12 317 817 0.21 12-13 4794 1522 0.58 13-14 5453 1494 0.61 14-15 5464 1473 0.55 15-16 2337 747 0.42 16-17 1392 2733 0.98 17-18 1953 976 0.13 Web 1-11 471 1438 0.17 1-12 4525 972 0.87 2-12 307 839 0.10 2-13 667 64 0.29 3-13 173 28 0.07 3-15 757 2986 0.74 5-15 698 60 0.31 5-16 1425 6501 0.64 6-16 247 790 0.09 7-16 618 2328 0.72 7-17 1054 172 0.46 8-17 377 1328 0.21 8-18 899 91 0.39 10-18 844 344 0.75 18-19 349 199 0.73 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 11 01-12 1527 115 05-08 01-10 DFL 625 16 27-01-04 3216 163 05-14 02-12 DFL 781 19 36-09-14 199 349 05-08 01-08 DFL 625 Max Horiz = -99 / +386 at Joint 11 Max Horiz = -99 / +386 at Joint 19 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [37-01-08] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Lateral forces from the bearing wall, if applicable, have not been considered in the design of the web(s) extended down to a bearing below the bottom chord. This condition may require additional design considerations and must be approved by the Building Designer. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/585(-0.55) 12-13 Vert DL L/120 L/999(-0.28) 12-13 Vert CR L/240 L/389(-0.83) 12-13 Horz LL 0.75in ( 0.54) @Jt16 Horz CR 1.25in ( 0.56) @Jt16 Ohng CR 2L/240 2L/999(-0.01) 1- 1 DPL LL L/120 L/176(-0.27) 19-18 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-10-00 -1-06-00 37-01-08 11 BC 5-08-00 0 36-06-04 7 ------- Web Bracing -- CLR ----------- Single: 3-15 5-16 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(00-08,0), Jnt5(00-04,00-01), Jnt7(-00-01,0), Jnt12(-00-04,-00-01), Jnt18(00-10,0) EngDrwg: 2021r5RGT_Eng 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 23 Truss: B06 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341923 TID:199573 Date:08 / 08 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 4x4 = 5x5 = 1.5x34x4 = 4x4 = 4x4 = 3x4= 1.5x3 4x4 =4x5 = 6x8 4x4 = 4x12 3-0-0 14 4- 6 - 7 9- 5 - 6 1- 9 - 1 2 1- 1 0 - 1 4 12 - 8 - 2 1 7-8-5 7-8-5 2 7-9-5 15-5-10 3 3-0-15 18-6-9 5 3-8-8 22-3-2 6 3-8-8 25-11-10 7 8 7-8-5 7-8-5 9 7-9-5 15-5-10 11 5-2-8 20-8-2 12 5-3-8 25-11-10 13 4 10 25-11-10 4.5/12 4.5/12 Truss Weight = 189.2 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL #2 1-9 2-11 2x10 DFL SS 14-7 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.69 Max CSI in BC PANEL 10 - 11 0.38 Max CSI in Web 2 - 11 0.74 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 669 2187 0.69 2- 3 952 300 0.47 3- 4 776 197 0.46 4- 5 835 191 0.20 5- 6 274 1108 0.11 6- 7 848 2452 0.43 7-OH 0 123 0.45 BC OH- 8 4 0 0.00 8- 9 247 703 0.27 9-10 2069 915 0.27 10-11 2119 912 0.38 11-12 817 448 0.27 12-13 1832 547 0.12 Web 1- 8 279 710 0.10 1- 9 1973 554 0.38 2- 9 235 289 0.07 2-11 885 2721 0.74 3-11 237 759 0.09 5-11 139 904 0.25 5-12 634 45 0.20 6-12 149 563 0.06 6-13 965 453 0.30 7-13 1199 690 0.69 13-14 567 823 0.66 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 8 01-12 809 55 03-00 01-08 DFL 625 11 15-05-10 1842 29 05-14 01-13 DFL 667 14 25-07-00 823 184 07-04 01-08 DFL 625 Max Horiz = -129 / +344 at Joint 8 Max Horiz = -129 / +344 at Joint 14 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [25-11-10] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Lateral forces from the bearing wall, if applicable, have not been considered in the design of the web(s) extended down to a bearing below the bottom chord. This condition may require additional design considerations and must be approved by the Building Designer. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.15) 9-11 Vert DL L/120 L/999(-0.08) 8- 9 Vert CR L/240 L/808(-0.23) 8- 9 Horz LL 0.75in ( 0.49) @Jt11 Horz CR 1.25in ( 0.50) @Jt11 Ohng CR 2L/240 2L/926(-0.09) 7- 7 DPL LL L/120 L/240(-0.25) 14-13 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-01-00 0 28-11-10 7 BC 8-11-00 0 25-02-06 4 ------- Web Bracing -- CLR ----------- Single: 2-11 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt13(00-14,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 231 Truss: BK1 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341924 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 3x4 =1.5x3 1.5x4 3x5 5x8ns 1- 3 - 5 1- 8 - 1 3 1 1-10-6 1-10-6 2 3 1-10-6 1-10-6 4 Drag = 350 plf Truss Weight = 16.3 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary Block 2x6 DFL 1800/1.8 TC 2x4 DFL 1800/1.8 BC 2x4 DFL 1800/1.8 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 1 - 2 0.04 Max CSI in BC PANEL 3 - 4 0.03 Max CSI in Web 1 - 4 0.24 ...Mem... Ten Comp .CSI. TC OH- 1 0 0 0.00 1- 2 326 326 0.04 2-OH 0 0 0.00 BC OH- 3 0 0 0.00 3- 4 325 325 0.03 4-OH 0 0 0.00 Web 1- 3 408 408 0.13 1- 4 769 769 0.24 2- 4 0 108 0.01 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 3 01-12 408 408 01-08 01-08 DFL 625 4 1-08-10 408 408 01-08 01-08 DFL 625 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [11-03] using a 1.00 Full and 0.00 Reduced load factor. This truss has been designed for a 350.0 plf Drag Load distributed along the top chord rake in each direction and continuously resisted along the bottom chord by a shear wall. This design is for a Shear Panel(blocking) application only! See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. A "pm" next to the plate size indicates that the plate has been user modified; see Plate Offsets for any special positioning requirements. Less than 0.25/12 pitch requires adequate drainage to prevent ponding. This truss is not symmetric - proper orientation is critical. Not designed for upside-down installation! Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999( 0.00) 3- 4 Vert DL L/120 L/999( 0.00) 3- 4 Vert CR L/240 L/999( 0.00) 3- 4 Horz LL 0.75in ( 0.00) @Jt 4 Horz CR 1.25in ( 0.00) @Jt 4 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 1-10-00 0 1-10-06 2 BC 1-10-00 0 1-10-06 2 Web Bracing -- None End Verticals require bracing indicated or must be continuously attached to other components. Plate offsets (X, Y): (None unless indicated below) Jnt3(0,-00-08) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: BK2 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341925 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 3x5 4x5= 4x5=3x51- 3 - 5 1- 3 - 5 1 1-7-6 1-7-6 2 3 1-7-6 1-7-6 4 Drag = 350 plf Truss Weight = 12.8 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x4 DFL 1800/1.8 BC 2x4 DFL 1800/1.8 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 1 - 2 0.03 Max CSI in BC PANEL 3 - 4 0.02 Max CSI in Web 3 - 2 0.22 ...Mem... Ten Comp .CSI. TC OH- 1 0 0 0.00 1- 2 281 281 0.03 2-OH 0 0 0.00 BC OH- 3 0 0 0.00 3- 4 282 282 0.02 4-OH 0 0 0.00 Web 1- 3 0 93 0.01 2- 3 703 703 0.22 2- 4 419 419 0.13 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 3 01-12 419 419 01-08 01-08 DFL 625 4 1-05-10 419 419 01-08 01-08 DFL 625 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [09-11] using a 1.00 Full and 0.00 Reduced load factor. This truss has been designed for a 350.0 plf Drag Load distributed along the top chord rake in each direction and continuously resisted along the bottom chord by a shear wall. This design is for a Shear Panel(blocking) application only! See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Less than 0.25/12 pitch requires adequate drainage to prevent ponding. This truss is not symmetric - proper orientation is critical. Designed to allow upside-down and/or backward installation. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999( 0.00) 3- 4 Vert DL L/120 L/999( 0.00) 3- 4 Vert CR L/240 L/999( 0.00) 3- 4 Horz LL 0.75in ( 0.00) @Jt 4 Horz CR 1.25in ( 0.00) @Jt 4 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 1-07-00 0 1-07-06 2 BC 1-07-00 0 1-07-06 2 Web Bracing -- None End Verticals require bracing indicated or must be continuously attached to other components. Plate offsets (X, Y): (None unless indicated below) Jnt1(0,00-11), Jnt2(0,00-11) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: BK3 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341926 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 3x4 =1.5x3 3x5 4x5= 3x5 3x3 = 4- 0 - 0 5 2- 2 - 0 4- 0 - 0 6 2- 2 - 0 6- 2 - 0 6- 2 - 0 1 1-7-6 1-7-6 2 3 1-7-6 1-7-6 4 Drag = 350 plf Truss Weight = 32.0 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x4 DFL 1800/1.8 BC 2x4 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL 1800/1.8 3-1 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.03 Max CSI in BC PANEL 3 - 4 0.02 Max CSI in Web 3 - 5 0.88 ...Mem... Ten Comp .CSI. TC OH- 1 0 0 0.00 1- 2 281 281 0.03 2-OH 0 0 0.00 BC OH- 3 0 0 0.00 3- 4 282 282 0.02 4-OH 0 0 0.00 Web 1- 5 860 860 0.10 1- 6 1027 1027 0.32 2- 6 0 93 0.01 3- 5 2504 2504 0.88 4- 5 1738 1738 0.55 4- 6 860 860 0.32 5- 6 563 563 0.18 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 3 01-12 2504 2504 01-08 02-11** DFL 625 4 1-05-10 2504 2504 01-08 02-11** DFL 625 (**) indicates Reqd Width > actual Width; enhancement may be required. Building Designer to provide adequate bearing size or enhancement. Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [09-11] using a 1.00 Full and 0.00 Reduced load factor. This truss has been designed for a 350.0 plf Drag Load distributed along the top chord rake in each direction and continuously resisted along the bottom chord by a shear wall. This design is for a Shear Panel(blocking) application only! See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Less than 0.25/12 pitch requires adequate drainage to prevent ponding. This truss is not symmetric - proper orientation is critical. Not designed for upside-down installation! Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999( 0.00) 3- 4 Vert DL L/120 L/999( 0.00) 3- 4 Vert CR L/240 L/999( 0.00) 3- 4 Horz LL 0.75in ( 0.00) @Jt 4 Horz CR 1.25in ( 0.00) @Jt 4 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 1-07-00 0 1-07-06 2 BC 1-07-00 0 1-07-06 2 Web Bracing -- None End Verticals require bracing indicated or must be continuously attached to other components. Plate offsets (X, Y): (None unless indicated below) Jnt3(0,-00-09), Jnt4(0,-00-09) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 191 Truss: BK4 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341927 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 3x4 =1.5x3 3x5 3x6 3x6 3x3 = 4- 2 - 0 5 2- 0 - 0 4- 2 - 0 6 2- 0 - 0 6- 2 - 0 6- 2 - 0 1 1-8-14 1-8-14 2 3 1-8-14 1-8-14 4 Drag = 350 plf Truss Weight = 32.7 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x4 DFL 1800/1.8 BC 2x4 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL 1800/1.8 3-1 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.03 Max CSI in BC PANEL 3 - 4 0.03 Max CSI in Web 3 - 5 0.86 ...Mem... Ten Comp .CSI. TC OH- 1 0 0 0.00 1- 2 305 305 0.03 2-OH 0 0 0.00 BC OH- 3 0 0 0.00 3- 4 303 303 0.03 4-OH 0 0 0.00 Web 1- 5 780 780 0.08 1- 6 990 990 0.31 2- 6 0 100 0.01 3- 5 2466 2466 0.86 4- 5 1792 1792 0.57 4- 6 780 780 0.27 5- 6 608 608 0.19 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 3 01-12 2466 2466 01-08 02-10** DFL 625 4 1-07-02 2466 2466 01-08 02-10** DFL 625 (**) indicates Reqd Width > actual Width; enhancement may be required. Building Designer to provide adequate bearing size or enhancement. Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [10-07] using a 1.00 Full and 0.00 Reduced load factor. This truss has been designed for a 350.0 plf Drag Load distributed along the top chord rake in each direction and continuously resisted along the bottom chord by a shear wall. This design is for a Shear Panel(blocking) application only! See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Less than 0.25/12 pitch requires adequate drainage to prevent ponding. This truss is not symmetric - proper orientation is critical. Not designed for upside-down installation! Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999( 0.00) 3- 4 Vert DL L/120 L/999( 0.00) 3- 4 Vert CR L/240 L/999( 0.00) 3- 4 Horz LL 0.75in ( 0.00) @Jt 3 Horz CR 1.25in ( 0.00) @Jt 3 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 1-08-00 0 1-08-14 2 BC 1-08-00 0 1-08-14 2 Web Bracing -- None End Verticals require bracing indicated or must be continuously attached to other components. Plate offsets (X, Y): (None unless indicated below) Jnt3(0,-00-09) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: C01 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341928 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 Typical plate: 1.5x3 4x5 = 4x10 4x5 = 4x5 =3x4 =3x4 =4x7 4x5 = 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1-6-0 1-6-0 2- 6 - 1 3 2- 6 - 1 3 7- 9 - 7 1 6-11-8 6-11-8 2 6-11-8 13-11-0 3 6-11-8 20-10-8 4 6-11-8 27-10-0 5 6 9-3-5 9-3-5 9 9-3-5 18-6-11 10 9-3-5 27-10-0 14 7 8 11 12 13 27-10-0 4.5/12 -4.5/12 Truss Weight = 264.0 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 20-00-00 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL #2 3-10 4-14 6-2 9-3 Member Forces Summary Max CSI in TC PANEL 2 - 3 0.59 Max CSI in BC PANEL 7 - 8 0.26 Max CSI in Web 6 - 2 0.62 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 147 101 0.35 2- 3 482 1945 0.59 3- 4 481 1945 0.59 4- 5 147 101 0.33 5-OH 69 0 0.11 BC OH- 6 0 0 0.00 6- 7 1804 307 0.14 7- 8 1804 307 0.26 8- 9 1804 307 0.26 9-10 1471 159 0.25 10-11 1804 327 0.20 11-12 1804 327 0.26 12-13 1804 327 0.26 13-14 1804 327 0.14 14-OH 0 0 0.00 Web 1- 6 255 460 0.13 2- 6 379 2196 0.62 2- 9 231 381 0.17 3- 9 564 113 0.11 3-10 564 113 0.11 4-10 231 381 0.17 4-14 379 2196 0.62 5-14 255 460 0.13 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 6 01-12 1711 129 3-00-00 14 27-08-04 1711 129 3-00-00 Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 6- 8 41 0 3-00-00 (reduced) 12- 14 41 0 3-00-00 (reduced) Max Horiz = -156 / +156 at Joint 6 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [13-11-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Gable webs are attached with min. 1x3 20 ga.plates. The max.rake overhang = 1/2 the truss spacing. If this truss is exposed to wind loads perpendicular to the plane of the truss, it must be braced according to a standard detail matching the wind criteria shown, or according to the Construction Documents and/or BCSI - B3. Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. This truss is not symmetric - proper orientation is critical. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.09) 9-10 Vert DL L/120 L/999(-0.07) 9-10 Vert CR L/240 L/999(-0.17) 9-10 Horz LL 0.75in ( 0.03) @Jt14 Horz CR 1.25in ( 0.04) @Jt14 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Ohng CR 2L/240 2L/999(-0.01) 5- 5 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-05-00 -1-06-00 29-04-00 7 BC 9-03-00 0 27-10-00 4 ------- Web Bracing -- CLR ----------- Single: 6- 2 4-14 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt2(-00-11,-00-04), Jnt4(00-11,-00-04), Jnt11(0,-02-00) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: C02 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341929 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 1.5x3 4x5 = 4x5 = 4x5 = 1.5x3 4x5 =3x4 =3x4 =4x4 =4x5 = 1-6-0 1-6-0 3- 4 - 1 1 3- 4 - 1 1 8- 7 - 5 1 6-11-8 6-11-8 2 6-11-8 13-11-0 3 6-11-8 20-10-8 4 6-11-8 27-10-0 5 6 2-9-4 2-9-4 7 6-6-1 9-3-5 8 9-3-5 18-6-11 9 6-6-1 25-0-12 11 2-9-4 27-10-0 1210 27-10-0 4.5/12 -4.5/12 Truss Weight = 193.0 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 20-00-00 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL #2 3-9 4-12 6-2 8-3 Member Forces Summary Max CSI in TC PANEL 2 - 3 0.58 Max CSI in BC PANEL 8 - 9 0.28 Max CSI in Web 6 - 2 0.63 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 147 101 0.43 2- 3 455 1733 0.58 3- 4 454 1733 0.58 4- 5 147 101 0.40 5-OH 69 0 0.11 BC OH- 6 0 0 0.00 6- 7 1550 254 0.21 7- 8 1550 254 0.27 8- 9 1337 162 0.28 9-10 1550 296 0.27 10-11 1550 296 0.21 11-12 1550 296 0.21 12-OH 0 0 0.00 Web 1- 6 251 458 0.19 2- 6 352 2001 0.63 2- 8 160 282 0.17 3- 8 468 98 0.09 3- 9 468 98 0.09 4- 9 160 282 0.17 4-12 351 2001 0.63 5-12 251 458 0.19 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 6 01-12 1685 126 05-08 01-13 DFL 625 7 2-09-04 263 0 05-08 01-08 DFL 667 11 25-00-12 263 0 05-08 01-08 DFL 667 12 27-08-04 1685 126 05-08 01-13 DFL 625 Max Horiz = -183 / +183 at Joint 6 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [13-11-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. This truss is not symmetric - proper orientation is critical. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.10) 8- 9 Vert DL L/120 L/999(-0.07) 8- 9 Vert CR L/240 L/999(-0.17) 8- 9 Horz LL 0.75in ( 0.02) @Jt12 Horz CR 1.25in ( 0.03) @Jt12 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Ohng CR 2L/240 2L/999(-0.01) 5- 5 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-05-00 -1-06-00 29-04-00 7 BC 9-03-00 0 27-10-00 4 ------- Web Bracing -- CLR ----------- Single: 6- 2 4-12 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt2(-00-11,-00-04), Jnt4(00-11,-00-04), Jnt8(00-01,0), Jnt9(-00-01,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 16 Truss: C03 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341930 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 1.5x3 4x4 = 4x5 = 4x4 = 1.5x3 3x5 3x4 =4x4 =3x4 =3x5 4- 4 - 2 4- 4 - 2 8- 7 - 5 1 5-8-4 5-8-4 2 5-8-4 11-4-8 3 5-8-4 17-0-12 4 5-8-4 22-9-0 5 6 7-7-0 7-7-0 7 7-7-0 15-2-0 9 7-7-0 22-9-0 10 8 22-9-0 4.5/12 -4.5/12 Truss Weight = 165.1 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 20-00-00 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL #2 3-9 4-10 6-2 7-3 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.31 Max CSI in BC PANEL 6 - 7 0.22 Max CSI in Web 6 - 2 0.42 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 144 74 0.31 2- 3 349 1226 0.30 3- 4 349 1226 0.30 4- 5 144 74 0.29 5-OH 5 0 0.00 BC OH- 6 0 0 0.00 6- 7 1034 250 0.22 7- 8 931 164 0.20 8- 9 931 164 0.20 9-10 1034 250 0.22 10-OH 0 0 0.00 Web 1- 6 109 228 0.30 2- 6 322 1532 0.42 2- 7 242 127 0.10 3- 7 311 72 0.06 3- 9 311 72 0.06 4- 9 242 127 0.10 4-10 322 1532 0.42 5-10 109 228 0.30 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 6 01-12 1417 44 05-08 01-08 DFL 625 10 22-07-04 1417 44 05-08 01-08 DFL 625 Max Horiz = -194 / +194 at Joint 6 Max Horiz = -194 / +194 at Joint 10 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [11-04-08] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. This truss is not symmetric - proper orientation is critical. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.04) 7- 9 Vert DL L/120 L/999(-0.02) 7- 9 Vert CR L/240 L/999(-0.06) 7- 9 Horz LL 0.75in ( 0.01) @Jt10 Horz CR 1.25in ( 0.02) @Jt10 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-10-00 0 22-09-00 6 BC 7-07-00 0 22-09-00 3 ------- Web Bracing -- CLR ----------- Single: 6- 2 7- 3 3- 9 4-10 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt2(-00-05,-00-02), Jnt4(00-05,-00-02), Jnt7(-00-01,0), Jnt9(00-01,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: D01 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341931 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 Typical plate: 1.5x3 4x4 = 4x4 =4x4 = 1-6-0 1-6-0 10-15 10-153- 1 0 - 3 3- 1 1 - 1 4 1 7-10-0 7-10-0 2 7-10-0 15-8-0 3 1 7-10-0 7-10-0 5 7-10-0 15-8-0 3 4 6 15-8-0 4.5/12 -4.5/12 Truss Weight = 90.3 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 20-00-00 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard Wedge 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 1 - 2 0.38 Max CSI in BC PANEL 1 - 4 0.15 Max CSI in Web 5 - 2 0.08 ...Mem... Ten Comp .CSI. TC OH- 1 63 0 0.09 1- 2 265 1015 0.38 2- 3 263 1015 0.38 3-OH 63 0 0.09 BC 1- 4 820 138 0.15 3- 6 820 138 0.15 4- 5 820 138 0.14 5- 6 820 138 0.14 Web 2- 5 186 2 0.08 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 1 05-04 1012 81 3-00-00 3 15-02-12 1012 81 3-00-00 Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 4 84 0 3-00-00 (reduced) 6- 3 84 0 3-00-00 (reduced) Max Horiz = -57 / +57 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [7-10-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Gable webs are attached with min. 1x3 20 ga.plates. The max.rake overhang = 1/2 the truss spacing. If this truss is exposed to wind loads perpendicular to the plane of the truss, it must be braced according to a standard detail matching the wind criteria shown, or according to the Construction Documents and/or BCSI - B3. Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Lumber and plating have been applied symmetrically. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.02) 4- 5 Vert DL L/120 L/999(-0.02) 4- 5 Vert CR L/240 L/999(-0.04) 4- 5 Horz LL 0.75in ( 0.01) @Jt 3 Horz CR 1.25in ( 0.02) @Jt 3 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Ohng CR 2L/240 2L/999(-0.01) 3- 3 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-11-00 -1-06-00 17-02-00 5 BC 7-10-00 0 15-08-00 2 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Jnt1(03-08,01-00), Jnt3(-03-08,01-00) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 6 Truss: D02 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341932 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 4x4 = 4x5 = 4x4 = 1.5x3 4x7 1.5x3 1-6-0 1-6-0 1- 8 - 1 3 1- 8 - 1 3 4- 8 - 1 1 7-10-0 7-10-0 2 7-10-0 15-8-0 3 4 2-9-4 2-9-4 5 5-0-12 7-10-0 6 5-1-10 12-11-10 7 2-8-6 15-8-0 8 15-8-0 4.5/12 -4.5/12 Truss Weight = 102.0 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 20-00-00 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL #2 1-6 6-3 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.65 Max CSI in BC PANEL 4 - 5 0.09 Max CSI in Web 1 - 6 0.15 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 273 958 0.65 2- 3 273 958 0.65 3-OH 69 0 0.11 BC OH- 4 0 0 0.00 4- 5 0 74 0.09 5- 6 0 74 0.09 6- 7 0 12 0.09 7- 8 0 12 0.09 8-OH 0 0 0.00 Web 1- 4 363 1091 0.13 1- 6 789 145 0.15 2- 6 106 227 0.06 3- 6 789 145 0.15 3- 8 363 1091 0.13 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 4 01-12 1082 99 05-08 01-08 DFL 625 5 2-09-04 254 0 05-08 01-08 DFL 667 7 12-11-10 255 0 07-04 01-08 DFL 625 8 15-06-04 1080 99 05-08 01-08 DFL 625 Max Horiz = -82 / +82 at Joint 4 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [7-10-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Lumber and plating have been applied symmetrically. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.02) 5- 6 Vert DL L/120 L/999(-0.01) 5- 6 Vert CR L/240 L/999(-0.03) 5- 6 Horz LL 0.75in ( 0.00) @Jt 8 Horz CR 1.25in ( 0.00) @Jt 8 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Ohng CR 2L/240 2L/999(-0.01) 3- 3 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-11-00 -1-06-00 17-02-00 5 BC 7-10-00 0 15-08-00 2 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 111 Truss: E01 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341933 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 2x4 4x7 4x8 1.5x3 2x4 1.5x3 4x8 4x7 2x4 5x7 5x7 4x7 5x7 5x7 2x3= 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 2x3= 1x3 1x31x3 1.5x3 1.5x3 1.5x3 1.5x3 1 - 9 - 8 1-9 -8 10 4- 1 0 - 5 151- 7 - 1 2 1 14 4- 1 0 - 5 251- 7 - 1 2 9 2- 5 - 8 6- 6 - 1 6- 6 - 1 11 - 4 - 0 29 30 1 6-5-4 6-5-4 2 6-5-4 12-10-8 3 8-9-8 21-8-0 5 8-9-8 30-5-8 7 6-5-4 36-10-12 8 6-5-4 43-4-0 9 10 12-4-14 12-4-14 11 9-3-2 21-8-0 12 9-3-3 30-11-3 13 12-4-13 43-4-0 14 4 6 43-4-0 4.5/12 -4.5/12 2.5/12 -2.5/12 Truss Weight = 361.7 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 30-05-08 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL 1800/1.8 8-14 10-2 2x4 DFL #2 2-11 3-12 7-13 11-3 12-5 12-7 13-8 Member Forces Summary Max CSI in TC PANEL 3 - 5 0.99 Max CSI in BC PANEL 10 - 11 0.59 Max CSI in Web 10 - 2 0.94 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 188 87 0.46 2- 3 600 3094 0.71 3- 5 689 3397 0.99 5- 7 689 3397 0.99 7- 8 600 3094 0.71 8- 9 188 87 0.43 9-OH 5 0 0.00 BC OH-10 2 0 0.00 10-11 1976 458 0.59 11-12 2776 463 0.36 12-13 2779 464 0.36 13-14 1977 458 0.59 14-OH 2 0 0.00 Web 1-10 123 262 0.60 2-10 643 3241 0.94 2-11 1179 94 0.22 3-11 145 181 0.05 3-12 847 197 0.20 5-12 357 995 0.29 7-29 831 191 0.17 7-30 143 156 0.03 8-13 1178 94 0.22 8-14 643 3241 0.94 9-14 123 262 0.60 12-29 844 196 0.17 13-30 141 177 0.05 29-30 8 25 0.00 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 10 01-12 2599 84 07-04 02-12 DFL 625 14 43-02-04 2599 84 07-04 02-12 DFL 625 Max Horiz = -282 / +282 at Joint 10 Max Horiz = -282 / +282 at Joint 14 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [21-08-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. This truss is not symmetric - proper orientation is critical. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.29) 10-11 Vert DL L/120 L/999(-0.31) 10-11 Vert CR L/240 L/863(-0.60) 10-11 Horz LL 0.75in ( 0.13) @Jt14 Horz CR 1.25in ( 0.20) @Jt14 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-10-00 0 14-01-02 4 TC 2-00-00 14-01-02 29-02-14 8 TC 4-10-00 29-02-14 43-04-00 4 BC 8-09-00 0 43-04-00 6 ------- Web Bracing -- CLR ----------- Single: 10- 2 11- 3 12- 5 7-13 8-14 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt2(-01-07,-00-09), Jnt8(01-07,-00-09), Jnt11(00-06,-01-14), Jnt13(-00-06,-01-14) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 1 Truss: E02 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341934 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 Typical plate: 1.5x3 2x4 8x8 = 4x7 2x4 4x7 8x8= 2x4 6x6 = 5x7 4x7 5x7 6x6 = 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x31x3 1x3 1x3 1x3 1x3 1x3 1x3 1x31x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 1x3 2- 5 - 8 5- 8 - 3 5- 8 - 2 11 - 4 - 0 1 7-8-0 7-8-0 2 7-4-13 15-0-13 3 6-7-3 21-8-0 4 6-7-3 28-3-2 5 7-4-14 35-8-0 6 7-8-0 43-4-0 7 8 12-4-14 12-4-14 9 9-3-2 21-8-0 10 9-3-4 30-11-3 11 12-4-13 43-4-0 12 43-4-0 4.5/12 -4.5/12 2.5/12 -2.5/12 Truss Weight = 491.8 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 28-03-03 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL 1800/1.8 6-12 8-2 2x4 DFL #2 2-9 3-10 5-11 9-3 10-4 10-5 11-6 Member Forces Summary Max CSI in TC PANEL 2 - 3 0.98 Max CSI in BC PANEL 8 - 9 0.60 Max CSI in Web 8 - 2 0.87 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 197 103 0.45 2- 3 594 3389 0.98 3- 4 608 3354 0.22 4- 5 608 3354 0.22 5- 6 594 3390 0.98 6- 7 197 103 0.41 7-OH 5 0 0.00 BC OH- 8 2 0 0.00 8- 9 2544 482 0.60 9-10 2998 408 0.32 10-11 2998 408 0.32 11-12 2545 482 0.59 12-OH 2 0 0.00 Web 1- 8 158 310 0.45 2- 8 607 3642 0.87 2- 9 855 8 0.16 3- 9 395 57 0.07 3-10 633 115 0.12 4-10 262 713 0.20 5-10 633 115 0.12 5-11 395 57 0.07 6-11 855 8 0.16 6-12 607 3643 0.87 7-12 158 310 0.45 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 8 01-12 2599 84 07-04 02-12 DFL 625 12 43-02-04 2599 84 07-04 02-12 DFL 625 Max Horiz = -272 / +272 at Joint 8 Max Horiz = -272 / +272 at Joint 12 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [21-08-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Gable webs are attached with min. 1x3 20 ga.plates. The max.rake overhang = 1/2 the truss spacing. If this truss is exposed to wind loads perpendicular to the plane of the truss, it must be braced according to a standard detail matching the wind criteria shown, or according to the Construction Documents and/or BCSI - B3. Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.27) 8- 9 Vert DL L/120 L/999(-0.30) 8- 9 Vert CR L/240 L/898(-0.57) 8- 9 Horz LL 0.75in ( 0.15) @Jt12 Horz CR 1.25in ( 0.22) @Jt12 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-00-00 0 14-01-02 4 TC 2-00-00 14-01-02 29-02-14 8 TC 5-00-00 29-02-14 43-04-00 4 BC 8-09-00 0 43-04-00 6 ------- Web Bracing -- CLR ----------- Single: 3-10 10- 4 10- 5 ------- Web Bracing -- CLR ----------- Double: 8- 2 6-12 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt9(00-06,-01-14), Jnt11(-00-06,-01-14) EngDrwg: 2021r5RGT_Eng 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: F01 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341935 TID:199573 Date:08 / 08 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 Typical plate: 1.5x3 4x4 = 4x4 = 4x4 = 5x7 5x7 1-5-8 1-5-8 7-8 7-82- 1 1 - 0 3- 4 - 1 2 7- 8 4-11-12 1- 8 - 0 1 2-2-0 2 1-4-0 3 1-4-0 4 8-0 5-6-0 5 8-0 6 1-4-0 7 1-4-0 8 2-2-0 11-0-0 9 1 2-2-0 10 1-4-0 11 1-4-0 4-10-0 12 1-4-0 6-2-0 13 1-4-0 14 1-4-0 15 2-2-0 11-0-0 9 11-0-0 5/12 -5/12 Truss Weight = 69.6 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 20-00-00 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 13.0 ft B = 11.0 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 3-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x4 DFL 1800/1.8 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 1 - 1 0.13 Max CSI in BC PANEL 1 - 10 0.06 Max CSI in Web 12 - 4 0.03 ...Mem... Ten Comp .CSI. TC 1- 5 92 0 0.13 5- 9 92 0 0.13 BC 1- 9 90 47 0.06 Web 2-10 68 180 0.02 3-11 69 188 0.02 4-12 33 206 0.03 6-13 33 206 0.03 7-14 69 188 0.02 8-15 68 180 0.02 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 1 02-06 526 54 11-00-00 9 10-09-10 526 54 11-00-00 Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 9 55 8 11-00-00 (reduced) Max Horiz = -23 / +23 at Joint 13 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [5-06-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Gable webs are attached with min. 1x3 20 ga.plates. The max.rake overhang = 1/2 the truss spacing. If this truss is exposed to wind loads perpendicular to the plane of the truss, it must be braced according to a standard detail matching the wind criteria shown, or according to the Construction Documents and/or BCSI - B3. Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Lumber and plating have been applied symmetrically. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/240 L/999( 0.00) 1-10 Vert DL L/120 L/999(-0.00) 1-10 Vert CR L/180 L/999( 0.00) 1-10 Horz LL 0.75in ( 0.00) @Jt 9 Horz CR 1.25in ( 0.00) @Jt 9 Ohng CR 2L/180 2L/999(-0.01) 1- 1 Ohng CR 2L/180 2L/999(-0.01) 9- 9 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-01-00 -1-07-10 12-07-10 4 BC 5-06-00 0 11-00-00 2 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 6 Truss: F02 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341936 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 4x4 = 4x4 = 4x4 = 1.5x3 1-5-8 1-5-8 7-8 7-82- 1 1 - 0 3- 4 - 1 2 1 5-6-0 5-6-0 2 5-6-0 11-0-0 3 1 5-6-0 5-6-0 4 5-6-0 11-0-0 3 11-0-0 5/12 -5/12 Truss Weight = 50.2 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 20-00-00 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 13.0 ft B = 11.0 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 3-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x4 DFL 1800/1.8 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 1 - 2 0.23 Max CSI in BC PANEL 1 - 4 0.24 Max CSI in Web 4 - 2 0.11 ...Mem... Ten Comp .CSI. TC OH- 1 92 0 0.13 1- 2 185 874 0.23 2- 3 185 874 0.23 3-OH 92 0 0.13 BC 1- 4 709 64 0.24 3- 4 709 64 0.24 Web 2- 4 248 0 0.11 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 1 01-12 1024 102 03-08 01-08 DFL 625 3 10-10-04 1024 102 03-08 01-08 DFL 625 Max Horiz = -23 / +23 at Joint 1 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [5-06-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Lumber and plating have been applied symmetrically. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/240 L/999(-0.01) 4- 3 Vert DL L/120 L/999(-0.02) 4- 3 Vert CR L/180 L/999(-0.03) 4- 3 Horz LL 0.75in ( 0.01) @Jt 3 Horz CR 1.25in ( 0.01) @Jt 3 Ohng CR 2L/180 2L/999(-0.01) 1- 1 Ohng CR 2L/180 2L/999(-0.01) 3- 3 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-01-00 -1-07-10 12-07-10 4 BC 5-06-00 0 11-00-00 2 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: GDR1 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341937 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 1.5x3 5x10 4x6 4x6 5x6 =5x10 1.5x3 4x10 4x7 7x8-18 =3x4 =4x7 4x10 2- 2 - 5 2- 2 - 5 1 3-0-12 3-0-12 2 5-6-8 8-7-4 3 5-6-8 14-1-12 4 5-6-8 19-8-4 6 3-0-12 22-9-0 7 8 5-10-0 5-10-0 9 5-6-8 11-4-8 11 5-6-8 16-11-0 12 5-10-0 22-9-0 13 5 10 22-9-0 2-Ply Truss Weight = 307.9 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 2 Repetitive Member Increase: No Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL #2 2-9 12-6 Member Forces Summary Max CSI in TC PANEL 3 - 4 0.99 Max CSI in BC PANEL 10 - 11 0.86 Max CSI in Web 8 - 2 0.58 ...Mem... Ten Comp .CSI. TC OH- 1 0 0 0.00 1- 2 0 18 0.18 2- 3 370 11908 0.73 3- 4 515 15990 0.99 4- 5 370 11908 0.59 5- 6 370 11908 0.73 6- 7 0 18 0.18 7-OH 0 0 0.00 BC OH- 8 0 0 0.00 8- 9 7763 312 0.45 9-10 15927 572 0.83 10-11 15927 572 0.86 11-12 15927 567 0.86 12-13 7763 297 0.45 13-OH 0 0 0.00 Web 1- 8 29 507 0.03 2- 8 336 9032 0.58 2- 9 4890 85 0.47 3- 9 232 4741 0.31 3-11 952 782 0.21 4-11 952 782 0.21 4-12 232 4741 0.31 6-12 4890 85 0.47 6-13 335 9032 0.58 7-13 29 507 0.03 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 8 01-12 5232 173 05-08 02-13 DFL 625 13 22-07-04 5232 173 05-08 02-13 DFL 625 Max Horiz = -42 / +42 at Joint 8 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [11-04-08] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. User Distributed Loads (plf) Mbr Load Uplift Start Load Uplift End Dir Description TC 340.0 -11 0 340.0 -11 22-09-00 Vert b06 @ 90 Deg 2-PLY TRUSS Fastener Spacing Fasten each ply to the adjacent ply as follows(rows staggered): TC 2x6, 2-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c. BC 2x6, 2-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c. WB 2x4, 1-row(s) of 0.131" dia. x 3.0" Nails @ 9.0" o.c. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Less than 0.25/12 pitch requires adequate drainage to prevent ponding. This truss is not symmetric - proper orientation is critical. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/804(-0.33) 9-11 Vert DL L/120 L/999(-0.17) 9-11 Vert CR L/240 L/536(-0.50) 9-11 Horz LL 0.75in ( 0.07) @Jt13 Horz CR 1.25in ( 0.11) @Jt13 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-06-00 0 22-09-00 5 BC 7-07-00 0 22-09-00 3 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Jnt8(01-08,0), Jnt10(0,00-12), Jnt13(-01-08,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 1 Truss: GDR2 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341938 TID:199573 Date:08 / 07 / 23 Page:1 of 2 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 4x4 = 4x4 = 6x12 4x7 3x4=6x12 4x4 = 4x4 = 2x6 3x4 =4x7 4x5 =3x4 =4x5 =4x7 3x4 =2x6 6- 6 - 1 6- 6 - 1 11 - 4 - 0 1 6-5-4 6-5-4 2 6-5-4 12-10-8 3 5-10-5 18-8-13 4 5-10-5 24-7-3 5 5-10-5 30-5-8 6 6-5-4 36-10-12 7 6-5-4 43-4-0 8 9 6-5-4 6-5-4 10 6-5-4 12-10-8 11 8-9-8 21-8-0 13 8-9-8 30-5-8 15 6-5-4 36-10-12 16 6-5-4 43-4-0 1712 14 43-4-0 4-Ply 4.5/12 -4.5/12 Truss Weight = 1685.6 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 4 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 30-05-08 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x10 DFL SS BC 2x6 DFL 1800/1.8 Webs 2x4 DFL #2 2x4 DFL Standard 9-1 17-8 Member Forces Summary Max CSI in TC PANEL 4 - 5 0.06 Max CSI in BC PANEL 11 - 12 0.11 Max CSI in Web 11 - 4 0.48 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 2230 3605 0.03 2- 3 3572 5516 0.04 3- 4 3335 5152 0.05 4- 5 4968 7384 0.06 5- 6 3335 5152 0.05 6- 7 3572 5516 0.04 7- 8 2230 3605 0.03 8-OH 5 0 0.00 BC OH- 9 0 0 0.00 9-10 227 219 0.04 10-11 3352 2064 0.06 11-12 7370 4985 0.11 12-13 7370 4985 0.11 13-14 7370 4985 0.11 14-15 7370 4985 0.11 15-16 3352 2064 0.06 16-17 227 219 0.04 17-OH 0 0 0.00 Web 1- 9 2712 4485 0.21 1-10 4602 2834 0.16 2-10 2021 3075 0.15 2-11 2986 2108 0.16 3-11 1679 1180 0.09 4-11 3374 4537 0.48 4-13 4761 158 0.16 5-13 354 4567 0.40 5-15 3374 4537 0.48 6-15 1679 1180 0.09 7-15 2986 2108 0.16 7-16 2021 3075 0.15 8-16 4602 2834 0.16 8-17 2712 4485 0.21 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 9 01-12 4519 2679 05-08 01-08 DFL 625 17 43-02-04 4519 2679 05-08 01-08 DFL 625 Max Horiz = -268 / +268 at Joint 9 Max Horiz = -268 / +268 at Joint 17 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [21-08-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. (User-created load combinations exist on this truss.) 4-PLY TRUSS Fastener Spacing Fasten through all plys as follows (rows staggered): TC 2x10, 3-row(s) of Simpson SDS25600 Screws @ 24.0" o.c.** BC 2x6, 2-row(s) of Simpson SDS25600 Screws @ 24.0" o.c. WB 2x4, 1-row(s) of Simpson SDS25600 Screws @ 9.0" o.c. ** Use additional fasteners of the same type (u.n.o.) within +/-12" of the location(s) indicated (except where approved hangers are used with fasteners that transfer the load to all plies): TC:18-09-08, 4, TC:24-06-08, 6 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. This truss is not symmetric - proper orientation is critical. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.10) 11-13 Vert DL L/120 L/999(-0.02) 11-13 Vert CR L/240 L/999(-0.12) 11-13 Horz LL 0.75in ( 0.03) @Jt17 Horz CR 1.25in ( 0.04) @Jt17 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-11-00 0 14-01-02 4 TC 2-00-00 14-01-02 29-02-14 8 TC 4-11-00 29-02-14 43-04-00 4 BC 8-08-00 0 43-04-00 5 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Jnt2(-00-02,-00-01), Jnt4(-00-03,01-03), Jnt7(00-02,-00-01), Jnt9(0,-00-15), Jnt17(0,-00-15) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 1 Truss: GDR2 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341938 TID:199573 Date:08 / 07 / 23 Page:2 of 2 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 Loadcase -- 99000 Load Diagram 3 Dur Factors: 1.60 1.60 Domain Type ------------Name------------ Dir plf-beg plf-end -x-beg-- -x-end-- -y-beg-- -y-end-- Top Dead ReducedTCDL Vert 12.00 12.00 0 12-10-08 6-06-01 11-04-00 Bottom Dead ReducedBCDL Vert 12.00 12.00 0 43-04-00 0 0 Top Dead ReducedTCDL Vert 12.00 12.00 12-10-08 30-05-08 11-04-00 11-04-00 Top Dead ReducedTCDL Vert 12.00 12.00 30-05-08 43-04-00 11-04-00 6-06-01 Domain Type ------------Name------------ Dir Lbs -x-loc-- -y-loc-- EQ plf sum DL plf Top Live User-Defined @ 90 Deg Vert 4000 18-08-13 10-11-06 1250.0 7.5 Top Live User-Defined @ 90 Deg Vert 4000 24-07-03 10-11-06 1250.0 7.5 Loadcase -- 99001 Load Case 4 Dur Factors: 1.60 1.60 Domain Type ------------Name------------ Dir plf-beg plf-end -x-beg-- -x-end-- -y-beg-- -y-end-- Top Dead TCDL Vert 20.00 20.00 0 12-10-08 6-06-01 11-04-00 Bottom Dead BCDL Vert 20.00 20.00 0 43-04-00 0 0 Top Dead TCDL Vert 20.00 20.00 12-10-08 30-05-08 11-04-00 11-04-00 Top Dead TCDL Vert 20.00 20.00 30-05-08 43-04-00 11-04-00 6-06-01 Domain Type ------------Name------------ Dir Lbs -x-loc-- -y-loc-- EQ plf sum DL plf Top Live Steeple @ 90 Deg Vert -5200 18-08-13 10-11-06 -1625.0 12.5 Top Live Steeple @ 90 Deg Vert 6000 24-07-03 10-11-06 1875.0 12.5 Loadcase -- 99002 Load Case 5 Dur Factors: 1.60 1.60 Domain Type ------------Name------------ Dir plf-beg plf-end -x-beg-- -x-end-- -y-beg-- -y-end-- Top Dead ReducedTCDL Vert 12.00 12.00 0 12-10-08 6-06-01 11-04-00 Bottom Dead ReducedBCDL Vert 12.00 12.00 0 43-04-00 0 0 Top Dead ReducedTCDL Vert 12.00 12.00 12-10-08 30-05-08 11-04-00 11-04-00 Top Dead ReducedTCDL Vert 12.00 12.00 30-05-08 43-04-00 11-04-00 6-06-01 Domain Type ------------Name------------ Dir Lbs -x-loc-- -y-loc-- EQ plf sum DL plf Top Live Steeple @ 90 Deg Vert -3200 18-08-13 10-11-06 -1000.0 7.5 Top Live Steeple @ 90 Deg Vert -3200 24-07-03 10-11-06 -1000.0 7.5 Loadcase -- 99005 Load Case 6 Dur Factors: 1.60 1.60 Domain Type ------------Name------------ Dir plf-beg plf-end -x-beg-- -x-end-- -y-beg-- -y-end-- Top Dead TCDL Vert 20.00 20.00 0 12-10-08 6-06-01 11-04-00 Bottom Dead BCDL Vert 20.00 20.00 0 43-04-00 0 0 Top Dead TCDL Vert 20.00 20.00 12-10-08 30-05-08 11-04-00 11-04-00 Top Dead TCDL Vert 20.00 20.00 30-05-08 43-04-00 11-04-00 6-06-01 Domain Type ------------Name------------ Dir Lbs -x-loc-- -y-loc-- EQ plf sum DL plf Top Live Steeple @ 90 Deg Vert -5200 18-08-13 10-11-06 -1625.0 12.5 Top Live Steeple @ 90 Deg Vert 6000 24-07-03 10-11-06 1875.0 12.5 Loadcase -- 99006 Load Case 7 Dur Factors: 1.60 1.60 Domain Type ------------Name------------ Dir plf-beg plf-end -x-beg-- -x-end-- -y-beg-- -y-end-- Top Dead TCDL Vert 20.00 20.00 0 12-10-08 6-06-01 11-04-00 Bottom Dead BCDL Vert 20.00 20.00 0 43-04-00 0 0 Top Dead TCDL Vert 20.00 20.00 12-10-08 30-05-08 11-04-00 11-04-00 Top Dead TCDL Vert 20.00 20.00 30-05-08 43-04-00 11-04-00 6-06-01 Domain Type ------------Name------------ Dir Lbs -x-loc-- -y-loc-- EQ plf sum DL plf Top Live Steeple @ 90 Deg Vert -5200 18-08-13 10-11-06 -1625.0 12.5 Top Live Steeple @ 90 Deg Vert 6000 24-07-03 10-11-06 1875.0 12.5 EngDrwg: 2021r5RGT_Eng 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: GDR3 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341939 TID:199573 Date:08 / 08 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 2x4 4x7 4x7 2x4 4x7 4x7 2x4 6x6 = 5x7 4x7 5x7 6x6 = 1.5x3 1.5x3 1.5x3 2x4 2x4 1.5x3 1.5x3 1.5x3 1 -0 - 4 1 -0 -4 8 4- 1 0 - 4 139- 1 5 1 12 4- 9 - 9 1810 - 9 7 2- 5 - 8 5- 8 - 3 5- 8 - 2 11 - 4 - 0 14 15 16 17 19 20 1 7-6-7 7-6-7 2 7-6-6 15-0-13 3 6-7-3 21-8-0 4 6-7-3 28-3-2 5 7-6-6 35-9-8 6 7-6-8 43-4-0 7 8 12-4-14 12-4-14 9 9-3-2 21-8-0 10 9-3-4 30-11-3 11 12-4-13 43-4-0 12 43-4-0 2-Ply 4.5/12 -4.5/12 2.5/12 -2.5/12 Truss Weight = 724.2 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 4-00-00 o.c. Plies: 2 Repetitive Member Increase: No Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 28-03-03 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL #2 2x6 DFL 1800/1.8 6-12 8-2 Member Forces Summary Max CSI in TC PANEL 2 - 3 0.66 Max CSI in BC PANEL 8 - 9 0.57 Max CSI in Web 8 - 16 0.97 ...Mem... Ten Comp .CSI. TC OH- 1 10 0 0.00 1- 2 264 701 0.63 2- 3 1169 6604 0.66 3- 4 1216 6706 0.30 4- 5 1216 6706 0.30 5- 6 1170 6603 0.65 6- 7 306 781 0.62 7-OH 10 0 0.00 BC OH- 8 3 0 0.00 8- 9 5008 960 0.57 9-10 6000 817 0.45 10-11 6001 817 0.45 11-12 5010 960 0.57 12-OH 3 0 0.00 Web 1-13 342 643 0.52 2-14 1705 19 0.18 2-16 1061 6770 0.76 3-10 1260 229 0.12 3-15 683 127 0.13 4-10 523 1412 0.20 5-10 1259 229 0.12 5-19 682 127 0.13 6-17 1027 6705 0.73 6-20 1705 20 0.18 7-18 383 797 0.47 8-13 302 573 0.52 8-16 1240 7299 0.97 9-14 1772 23 0.19 9-15 761 108 0.14 11-19 761 108 0.14 11-20 1772 24 0.19 12-17 1245 7309 0.96 12-18 299 575 0.47 13-16 575 215 0.05 14-15 14 195 0.02 17-18 665 252 0.06 19-20 14 196 0.02 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 8 01-12 5200 169 07-04 02-12 DFL 625 12 43-02-04 5199 169 07-04 02-12 DFL 625 Max Horiz = -545 / +545 at Joint 8 Max Horiz = -545 / +545 at Joint 12 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [21-08-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. 2-PLY TRUSS Fastener Spacing Fasten each ply to the adjacent ply as follows(rows staggered): TC 2x6, 2-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c. BC 2x6, 2-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c. WB 2x4, 1-row(s) of 0.131" dia. x 3.0" Nails @ 9.0" o.c. WB 2x6, 2-row(s) of 0.131" dia. x 3.0" Nails @ 9.0" o.c. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.27) 8- 9 Vert DL L/120 L/999(-0.30) 8- 9 Vert CR L/240 L/903(-0.57) 8- 9 Horz LL 0.75in ( 0.15) @Jt12 Horz CR 1.25in ( 0.22) @Jt12 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-00-00 0 14-01-02 4 TC 2-00-00 14-01-02 29-02-14 8 TC 5-00-00 29-02-14 43-04-00 4 BC 8-09-00 0 43-04-00 6 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Jnt2(-01-08,-00-09), Jnt6(01-08,-00-09), Jnt9(00-06,-01-14), Jnt11(-00-06,-01-14) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 1 Truss: GDR4 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341940 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 1.5x3 4x5 = 3x5 4x5 = 1.5x3 4x5 =8x8 =4x5 = 1758#1678#1686#1456#1476# 1- 8 - 1 3 1- 8 - 1 3 4- 8 - 1 1 3-11-0 3-11-0 2 3-11-0 7-10-0 3 3-11-0 11-9-0 4 3-11-0 15-8-0 5 6 2-9-4 2-9-4 7 5-0-12 7-10-0 8 5-0-12 12-10-12 9 2-9-4 15-8-0 10 15-8-0 2-Ply 4.5/12 -4.5/12 Truss Weight = 206.4 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 2 Repetitive Member Increase: No Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 20-00-00 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x4 DFL 1800/1.8 BC 2x8 DFL 2250/2.0 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 2 - 3 0.22 Max CSI in BC PANEL 6 - 7 0.44 Max CSI in Web 8 - 3 0.58 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 111 71 0.19 2- 3 5 4392 0.22 3- 4 5 4392 0.22 4- 5 112 71 0.19 5-OH 5 0 0.00 BC OH- 6 0 0 0.00 6- 7 3319 0 0.44 7- 8 3319 0 0.44 8- 9 3319 0 0.39 9-10 3319 0 0.39 10-OH 0 0 0.00 Web 1- 6 77 218 0.02 2- 6 9 4115 0.31 2- 8 881 11 0.19 3- 8 2645 0 0.58 4- 8 909 10 0.20 4-10 9 4115 0.31 5-10 77 217 0.02 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 6 01-12 1827 32 05-08 01-08 DFL 670 7 2-09-04 3741 0 05-08 01-12 DFL 703 9 12-10-12 2448 0 05-08 01-08 DFL 703 10 15-06-04 1937 46 05-08 01-08 DFL 670 Max Horiz = -84 / +84 at Joint 6 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [7-10-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Loads based on maximum and minimum reactions from tie-in spans Mbr Max Min Location Dir Description Transfer loads: BC 1758 9 3-04-00 Vert J22 @ -90 Deg BC 1678 24 5-04-00 Vert J23 @ -90 Deg BC 1686 32 7-04-00 Vert J24 @ -90 Deg BC 1456 55 9-04-00 Vert J25 @ -90 Deg BC 1476 62 11-04-00 Vert J26 @ -90 Deg 2-PLY TRUSS Fastener Spacing Fasten each ply to the adjacent ply as follows(rows staggered): TC 2x4, 1-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c. BC 2x8, 2-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c.** WB 2x4, 1-row(s) of 0.131" dia. x 3.0" Nails @ 9.0" o.c. ** Use additional fasteners of the same type (u.n.o.) within +/-12" of the location(s) indicated (except where approved hangers are used with fasteners that transfer the load to all plies): BC:3-04-00, 5, BC:5-04-00, 4, BC:7-04-00, 4 BC:9-04-00, 3, BC:11-04-00, 3 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Lumber and plating have been applied symmetrically. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.06) 8- 9 Vert DL L/120 L/999(-0.03) 8- 9 Vert CR L/240 L/999(-0.09) 8- 9 Horz LL 0.75in ( 0.01) @Jt10 Horz CR 1.25in ( 0.01) @Jt10 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-06-00 0 15-08-00 4 BC 7-10-00 0 15-08-00 2 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Jnt2(-00-04,-00-02), Jnt4(00-04,-00-02), Jnt8(0,-01-13) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 1 Truss: GDR5 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341941 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 1.5x3 4x5 = 3x5 4x5 = 1.5x3 4x5 =8x8 =4x5 = 1476#1456#1686#1678#1758# 1- 8 - 1 3 1- 8 - 1 3 4- 8 - 1 1 3-11-0 3-11-0 2 3-11-0 7-10-0 3 3-11-0 11-9-0 4 3-11-0 15-8-0 5 6 2-9-4 2-9-4 7 5-0-12 7-10-0 8 5-0-12 12-10-12 9 2-9-4 15-8-0 10 15-8-0 2-Ply 4.5/12 -4.5/12 Truss Weight = 206.4 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 2 Repetitive Member Increase: No Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 20-00-00 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x4 DFL 1800/1.8 BC 2x8 DFL 2250/2.0 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 3 - 4 0.22 Max CSI in BC PANEL 8 - 9 0.44 Max CSI in Web 8 - 3 0.58 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 112 71 0.19 2- 3 5 4392 0.22 3- 4 5 4392 0.22 4- 5 111 71 0.19 5-OH 5 0 0.00 BC OH- 6 0 0 0.00 6- 7 3319 0 0.39 7- 8 3319 0 0.39 8- 9 3319 0 0.44 9-10 3319 0 0.44 10-OH 0 0 0.00 Web 1- 6 77 217 0.02 2- 6 9 4115 0.31 2- 8 909 11 0.20 3- 8 2645 0 0.58 4- 8 881 10 0.19 4-10 9 4115 0.31 5-10 77 218 0.02 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 6 01-12 1937 46 05-08 01-08 DFL 670 7 2-09-04 2448 0 05-08 01-08 DFL 703 9 12-10-12 3741 0 05-08 01-12 DFL 703 10 15-06-04 1827 32 05-08 01-08 DFL 670 Max Horiz = -84 / +84 at Joint 6 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [7-10-00] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Loads based on maximum and minimum reactions from tie-in spans Mbr Max Min Location Dir Description Transfer loads: BC 1476 62 4-04-00 Vert J26 @ -90 Deg BC 1456 55 6-04-00 Vert J25 @ -90 Deg BC 1686 32 8-04-00 Vert J24 @ -90 Deg BC 1678 24 10-04-00 Vert J23 @ -90 Deg BC 1758 9 12-04-00 Vert J22 @ -90 Deg 2-PLY TRUSS Fastener Spacing Fasten each ply to the adjacent ply as follows(rows staggered): TC 2x4, 1-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c. BC 2x8, 2-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c.** WB 2x4, 1-row(s) of 0.131" dia. x 3.0" Nails @ 9.0" o.c. ** Use additional fasteners of the same type (u.n.o.) within +/-12" of the location(s) indicated (except where approved hangers are used with fasteners that transfer the load to all plies): BC:4-04-00, 3, BC:6-04-00, 3, BC:8-04-00, 4 BC:10-04-00, 4, BC:12-04-00, 5 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Lumber and plating have been applied symmetrically. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.06) 8- 9 Vert DL L/120 L/999(-0.03) 8- 9 Vert CR L/240 L/999(-0.09) 8- 9 Horz LL 0.75in ( 0.01) @Jt10 Horz CR 1.25in ( 0.01) @Jt10 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-06-00 0 15-08-00 4 BC 7-10-00 0 15-08-00 2 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Jnt2(-00-04,-00-02), Jnt4(00-04,-00-02), Jnt8(0,-01-13) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: GDR6 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341942 TID:199573 Date:08 / 07 / 23 Page:1 of 2 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x10 4x4 = 4x4 = 4x5 = 4x4 = 4x5 =5x6 = 6x8 2x4 2x6 6x10-18 3x4 =5x8-18 3x4 =4x5 =8x8 =6x8 6x10 3x4 = 2x4 1.5x3 1.5x3 1.5x4 1.5x4 1.5x3 1.5x3 1.5x4 1.5x4 1.5x3 1.5x4 3x3 = 1.5x3 3x3 = 2x4 45# 45# -15# -15# 158# 158# 262# 262#432# 432#674# 674#794# 794#914# 914#1034# 1034#1155# 1155#1275# 1275#1395# 1395#1516# 1515# 1636#1635#577# 577# 34# 34# 54# 54# 2-1-7 18 10 - 1 1 - 8 201- 7 - 1 4 9 1- 8 - 1 3 12 - 7 - 6 19 21 22 23 24 25 26 27 28 29 30 1 6-10-2 6-10-2 2 6-10-2 13-8-4 3 6-10-2 20-6-6 5 6-10-2 27-4-8 7 6-10-2 34-2-10 8 6-10-2 41-0-12 9 10 6-10-2 6-10-2 11 6-10-2 13-8-4 12 6-10-2 20-6-6 14 6-10-2 27-4-8 15 6-10-2 34-2-10 17 6-10-2 41-0-12 18 4 6 13 16 41-0-12 3-Ply 3.18/12 Truss Weight = 1299.4 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 1-00-00 o.c. Plies: 3 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x6 DFL 1800/1.8 2x4 DFL Standard 10-1 12-3 14-5 2x8 DFL 2250/2.0 1-11 30-20 2x4 DFL #2 2-12 3-14 11-2 18-9 2x4 DFL 2400/2.0 5-15 15-7 17-8 2x6 DFL 2400/2.0 28-29 SB 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 2 - 3 0.35 Max CSI in BC PANEL 12 - 13 0.64 Max CSI in Web 26 - 27 0.87 ...Mem... Ten Comp .CSI. TC OH- 1 34 0 0.03 1- 2 1772 19348 0.30 2- 3 1944 22330 0.35 3- 4 1859 21171 0.27 4- 5 1865 21126 0.27 5- 6 1570 17404 0.20 6- 7 1573 17339 0.17 7- 8 866 9394 0.09 8- 9 63 372 0.06 9-OH 0 2 0.00 BC OH-10 0 0 0.00 10-11 670 315 0.07 11-12 20162 1953 0.60 12-13 22792 2118 0.64 13-14 22792 2118 0.64 14-15 20469 1936 0.57 15-16 15857 1632 0.44 16-17 15857 1632 0.45 17-18 8798 1167 0.25 18-OH 0 0 0.00 Web 1-10 916 9312 0.37 1-19 19039 1731 0.66 2-21 342 3452 0.29 2-22 3452 220 0.39 3-23 523 640 0.14 3-24 102 1170 0.08 5-25 3278 233 0.61 5-26 337 4476 0.59 7-27 8945 636 0.85 7-28 744 9884 0.39 8-29 12597 866 0.52 8-30 1029 13600 0.68 ...Mem... Ten Comp .CSI. 9-20 73 94 0.36 11-19 20252 1952 0.68 11-21 351 3547 0.29 12-22 2864 170 0.35 12-23 100 1024 0.10 14-24 257 2837 0.12 14-25 1702 100 0.38 15-26 531 6839 0.84 15-27 4973 330 0.74 17-28 858 11494 0.54 17-29 9089 614 0.42 18-20 242 3078 0.68 18-30 1195 16528 0.85 19-21 259 1396 0.03 20-30 1132 526 0.63 21-22 326 1832 0.03 22-23 292 1524 0.27 23-24 233 1450 0.03 24-25 345 406 0.50 26-27 1509 192 0.87 28-29 1206 210 0.86 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 10 01-12 9410 922 05-08 03-06 DFL 625 18 40-11-00 17095 1200 05-08 HGR DFL 625 Max Horiz = -666 / +193 at Joint 10 Max Horiz = -666 / +193 at Joint 18 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [41-00-12] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Loads based on maximum and minimum reactions from tie-in spans Mbr Max Min Location Dir Description Transfer loads: TC 45 -27 2-04-14 Vert J01 @ 135 Deg TC 45 -27 2-04-14 Vert J01 @ -135 Deg TC 158 -28 5-02-13 Vert J02 @ 135 Deg TC 158 -28 5-02-13 Vert J02 @ -135 Deg TC 262 -50 8-00-12 Vert J03 @ 135 Deg TC 262 -50 8-00-12 Vert J03 @ -135 Deg BC 12 -15 2-04-14 Vert J01 @ 135 Deg BC 12 -15 2-04-14 Vert J01 @ -135 Deg Transfer loads: Web 34 -6 5-02-13 Vert J02 @ 90 Deg Web 34 -6 5-02-13 Vert J02 @ 90 Deg Web 54 10 8-00-12 Vert J03 @ 90 Deg Web 54 10 8-00-12 Vert J03 @ 90 Deg Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.38) 12-14 Vert DL L/120 L/999(-0.18) 12-14 Vert CR L/240 L/874(-0.56) 12-14 Horz LL 0.75in ( 0.11) @Jt18 Horz CR 1.25in ( 0.16) @Jt18 Ohng CR 2L/240 2L/999(-0.00) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-07-00 -2-01-07 41-00-12 9 BC 8-02-00 0 41-00-12 6 ------- Web Bracing -- CLR ----------- Single: 8-18 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(01-08,0), Jnt7(-00-09,-00-02), Jnt8(-01-02,-00-05), Jnt11(-01-08,0), Jnt16(0,01-04), Jnt17(-00-08,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: GDR6 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341942 TID:199573 Date:08 / 07 / 23 Page:2 of 2 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 Web 432 -42 10-10-11 Vert J04 @ 135 Deg Web 432 -42 10-10-11 Vert J04 @ -135 Deg Web 577 -46 13-10-00 Vert J05 @ 90 Deg Web 577 -46 13-10-00 Vert J05 @ 90 Deg Web 674 -58 16-06-09 Vert J06 @ 135 Deg Web 674 -58 16-06-09 Vert J06 @ -135 Deg Web 794 -66 19-04-08 Vert J07 @ 135 Deg Web 794 -66 19-04-08 Vert J07 @ -135 Deg Web 914 -74 22-02-07 Vert J08 @ 135 Deg Web 914 -74 22-02-07 Vert J08 @ -135 Deg Web 1034 -82 25-00-06 Vert J09 @ 135 Deg Web 1034 -82 25-00-06 Vert J09 @ -135 Deg Web 1155 -89 27-10-05 Vert J10 @ -135 Deg Web 1155 -89 27-10-05 Vert J10 @ 135 Deg Web 1275 -97 30-08-04 Vert J11 @ 135 Deg Web 1275 -97 30-08-04 Vert J11 @ -135 Deg Web 1395 -105 33-06-03 Vert J12 @ 135 Deg Web 1395 -105 33-06-03 Vert J12 @ -135 Deg Web 1516 -113 36-04-03 Vert J20 @ 135 Deg Web 1515 -113 36-04-03 Vert J13 @ -135 Deg Web 1636 -121 39-02-02 Vert J21 @ 135 Deg Web 1635 -121 39-02-02 Vert J14 @ -135 Deg 3-PLY TRUSS Fastener Spacing Fasten through all plys as follows (rows staggered): TC 2x6, 2-row(s) of Simpson SDS25412 Screws @ 24.0" o.c. BC 2x6, 2-row(s) of Simpson SDS25412 Screws @ 24.0" o.c. WB 2x4, 1-row(s) of Simpson SDS25412 Screws @ 9.0" o.c. WB 2x6, 2-row(s) of Simpson SDS25412 Screws @ 9.0" o.c.** WB 2x8, 2-row(s) of Simpson SDS25412 Screws @ 9.0" o.c. ** Use additional fasteners of the same type (u.n.o.) within +/-12" of the location(s) indicated (except where approved hangers are used with fasteners that transfer the load to all plies): WB:39-02-02, 1 Web members contain point loads. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Loads Summary (Continued) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: GDR7 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341943 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 4x10 4x4 = 4x4 = 4x4 = 4x5 = 4x5 = 4x6 4x4 = 4x4 = 4x5 =4x4 = 6x8 2x4 4x5 = 4x10 4x4 = 4x4 = 4x4 =4x5 = 4x5 = 4x6 4x4 = 4x4 = 5x12 1800# 1-6-0 3-0-0 4- 6 - 7 14 - 6 - 3 1- 8 - 1 3 1- 1 0 - 1 4 17 - 9 - 5 1 4-10-6 4-10-6 2 4-10-6 9-8-12 3 4-10-6 14-7-2 4 4-10-6 19-5-8 6 4-10-6 24-3-14 7 4-11-6 29-3-4 8 3-2-15 32-6-3 9 3-3-14 35-10-2 11 3-11-2 39-9-4 12 13 4-10-6 4-10-6 15 4-10-6 9-8-12 16 4-10-6 14-7-2 17 4-10-6 19-5-8 18 4-10-6 24-3-14 20 4-11-6 29-3-4 21 3-2-15 32-6-3 22 3-3-14 35-10-2 23 3-3-14 39-2-0 24 7-4 39-9-4 5 10 14 19 39-9-4 2-Ply 4.5/12 4.5/12 Truss Weight = 575.2 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 2 Repetitive Member Increase: No Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = No Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard BB 2x8 2.0E Microllam LVL Truss Chord Member Forces Summary Max CSI in TC PANEL 7 - 8 0.50 Max CSI in BC PANEL 21 - 22 0.50 Max CSI in Web 1 - 15 0.84 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.06 1- 2 1021 4170 0.14 2- 3 1454 6259 0.22 3- 4 1455 6292 0.23 4- 5 1065 4294 0.16 5- 6 1075 4204 0.15 6- 7 314 327 0.08 7- 8 5685 1341 0.50 8- 9 3531 1266 0.40 9-10 1682 1903 0.10 10-11 1699 1891 0.10 11-12 1477 2971 0.08 12-OH 0 109 0.20 BC OH-13 4 0 0.00 13-14 335 801 0.07 14-15 353 792 0.07 15-16 4102 1592 0.26 16-17 6184 1830 0.36 17-18 6229 1660 0.35 18-19 4205 1110 0.24 19-20 4232 1105 0.24 20-21 345 217 0.21 21-22 1320 5721 0.50 22-23 1827 3541 0.13 23-24 2503 1655 0.09 Web 1-13 486 1559 0.09 1-15 3839 864 0.84 2-15 332 1065 0.06 2-16 1987 354 0.44 3-16 161 491 0.03 3-17 292 279 0.06 4-17 182 0 0.04 4-18 516 1881 0.15 6-18 652 94 0.14 6-20 905 3937 0.31 7-20 1115 175 0.24 7-21 1132 5239 0.41 8-21 368 1536 0.09 8-22 2048 405 0.45 ...Mem... Ten Comp .CSI. 9-22 239 966 0.05 9-23 1890 393 0.41 11-23 211 725 0.04 11-24 1046 189 0.23 12-24 1633 422 0.36 BBK 12-24 240 2020 0.37 12-24 199 2275 0.36 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 13 01-12 1632 124 05-08 01-08 DFL 625 21 29-03-04 3431 233 05-14 01-11 DFL 667 24 39-05-10 2020 240 07-04 01-08 DFL 625 Max Horiz = -11 / +484 at Joint 13 Max Horiz = -11 / +484 at Joint 24 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [39-09-04] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Loads based on maximum and minimum reactions from tie-in spans Mbr Max Min Location Dir Description User loads: TC 1800 -59 39-08-00 Vert User @ 90 Deg 2-PLY TRUSS Fastener Spacing Fasten each ply to the adjacent ply as follows(rows staggered): TC 2x6, 2-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c.** BC 2x6, 2-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c. WB 2x4, 1-row(s) of 0.131" dia. x 3.0" Nails @ 9.0" o.c. ** Use additional fasteners of the same type (u.n.o.) within +/-12" of the location(s) indicated (except where approved hangers are used with fasteners that transfer the load to all plies): TC:39-08-00, 6 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Lateral forces from the bearing wall, if applicable, have not been considered in the design of the web(s) extended down to a bearing below the bottom chord. This condition may require additional design considerations and must be approved by the Building Designer. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.30) 16-17 Vert DL L/120 L/999(-0.15) 16-17 Vert CR L/240 L/771(-0.45) 16-17 Horz LL 0.75in ( 0.47) @Jt12 Horz CR 1.25in ( 0.48) @Jt12 Ohng CR 2L/240 2L/999(-0.00) 1- 1 Ohng CR 2L/240 2L/999(-0.03) 12-12 DPL LL L/120 L/194(-0.29) 25-25 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-10-00 -1-06-00 42-09-04 9 BC 8-04-00 0 39-02-00 6 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Jnt1(01-14,00-11), Jnt12(01-15,01-04), Jnt15(-01-03,-00-07), Jnt24(04-00,00-06) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: J01 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341944 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 1.5x3 1.5x3 1-6-0 4- 1 1 1- 8 - 1 3 1- 1 0 - 1 4 2- 3 - 9 1 1-6-1 1-6-1 2 3 1-6-1 1-6-1 4 4.5/12 4.5/12 Truss Weight = 11.2 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 1 - 1 0.11 Max CSI in BC PANEL 3 - 4 0.04 Max CSI in Web 3 - 1 0.54 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 15 62 0.10 BC OH- 3 4 0 0.00 3- 4 18 21 0.04 Web 1- 3 298 375 0.54 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 3 01-12 402 4 05-08 01-08 DFL 625 4 1-06-01 53 13 01-10 01-08 DFL 625 2 1-06-01 45 69 01-10 01-08 DFL 625 Max Horiz = -5 / +52 at Joint 3 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [1-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 3- 4 Vert DL L/120 L/999(-0.00) 3- 4 Vert CR L/240 L/999(-0.00) 3- 4 Horz LL 0.75in ( 0.01) @Jt 2 Horz CR 1.25in ( 0.01) @Jt 2 Ohng CR 2L/240 2L/999( 0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-02-00 -1-06-00 1-06-01 2 BC 1-07-00 0 1-06-01 2 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: J02 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341945 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 4x4 = 1.5x3 2x4 1-6-0 1- 1 - 1 1 1- 8 - 1 3 1- 1 0 - 1 4 3- 0 - 9 1 3-6-1 3-6-1 2 3 2-0-3 2-0-3 4 1-5-14 3-6-1 5 3-6-1 4.5/12 4.5/12 Truss Weight = 23.2 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 1 - 1 0.11 Max CSI in BC PANEL 3 - 4 0.07 Max CSI in Web 3 - 1 0.11 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 61 73 0.11 BC OH- 3 4 0 0.00 3- 4 44 192 0.07 4- 5 47 24 0.06 Web 1- 3 280 380 0.11 1- 4 190 41 0.06 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 3 01-12 417 0 05-08 01-08 DFL 625 5 3-06-01 133 5 01-10 01-08 DFL 625 2 3-06-01 174 27 01-10 01-08 DFL 625 Max Horiz = -5 / +73 at Joint 3 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [3-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 3- 4 Vert DL L/120 L/999(-0.00) 3- 4 Vert CR L/240 L/999(-0.00) 3- 4 Horz LL 0.75in ( 0.00) @Jt 2 Horz CR 1.25in ( 0.00) @Jt 2 Ohng CR 2L/240 2L/999( 0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-04-00 -1-06-00 3-06-01 2 BC 3-08-00 0 3-06-01 2 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: J03 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341946 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 4x4 = 1.5x3 2x4 1-6-0 1- 1 0 - 1 1 1- 8 - 1 3 1- 1 0 - 1 4 3- 9 - 9 1 5-6-1 5-6-1 2 3 2-0-3 2-0-3 4 3-5-14 5-6-1 5 5-6-1 4.5/12 4.5/12 Truss Weight = 31.6 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 1 - 2 0.21 Max CSI in BC PANEL 3 - 4 0.15 Max CSI in Web 3 - 1 0.10 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 91 103 0.21 BC OH- 3 4 0 0.00 3- 4 45 222 0.15 4- 5 61 20 0.15 Web 1- 3 259 464 0.10 1- 4 229 52 0.07 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 3 01-12 521 0 05-08 01-08 DFL 625 5 5-06-01 176 0 01-10 01-08 DFL 625 2 5-06-01 261 49 01-10 01-08 DFL 625 Max Horiz = -5 / +94 at Joint 3 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [5-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.01) 4- 5 Vert DL L/120 L/999(-0.01) 4- 5 Vert CR L/240 L/999(-0.02) 4- 5 Horz LL 0.75in ( 0.01) @Jt 2 Horz CR 1.25in ( 0.02) @Jt 2 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-08-00 -1-06-00 5-06-01 3 BC 5-10-00 0 5-06-01 2 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: J04 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341947 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 4x4 = 5x7 1.5x3 4x12 1-6-0 2- 1 2- 5 - 1 0 1- 8 - 1 3 1- 1 0 - 1 4 4- 6 - 9 1 7-6-1 7-6-1 2 3 7-0-9 7-0-9 4 5-8 7-6-1 7-6-1 4.5/12 4.5/12 Truss Weight = 55.1 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard BB 2x6 DFL 1800/1.8 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.35 Max CSI in BC PANEL 3 - 4 0.23 Max CSI in Web 3 - 1 0.13 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 34 329 0.35 BC OH- 3 4 0 0.00 3- 4 93 302 0.23 Web 1- 3 343 559 0.13 1- 4 201 0 0.09 2- 4 380 465 0.12 BBK 2- 4 206 396 0.02 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 3 01-12 630 43 05-08 01-08 DFL 625 4 7-05-05 431 42 01-08 HGR DFL 1750 Max Horiz = -22 / +95 at Joint 3 Max Horiz = -22 / +95 at Joint 4 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [7-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.03) 3- 4 Vert DL L/120 L/999(-0.03) 3- 4 Vert CR L/240 L/999(-0.06) 3- 4 Horz LL 0.75in ( 0.00) @Jt 2 Horz CR 1.25in ( 0.00) @Jt 2 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-09-00 -1-06-00 7-06-01 3 BC 7-06-00 0 7-00-09 2 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Jnt2(01-08,00-09), Jnt4(02-07,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: J05 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341948 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 1.5x3 4x4 = 1.5x3 4x4 = 4x4 = 1-6-0 3- 4 - 1 1 1- 8 - 1 3 1- 1 0 - 1 4 5- 3 - 9 1 4-7-3 4-7-3 2 4-10-14 9-6-1 3 4 9-6-1 9-6-1 5 4.5/12 4.5/12 Truss Weight = 60.5 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 2 - 3 0.15 Max CSI in BC PANEL 4 - 5 0.36 Max CSI in Web 4 - 2 0.48 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 95 78 0.13 2- 3 73 91 0.15 3-OH 0 12 0.00 BC OH- 4 4 0 0.00 4- 5 886 672 0.36 5-OH 0 9 0.00 Web 1- 4 239 394 0.09 2- 4 403 976 0.48 2- 5 604 802 0.33 3- 5 148 241 0.07 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 4 01-12 731 9 05-08 01-08 DFL 625 5 9-02-05 577 45 01-10 HGR DFL 625 Max Horiz = -22 / +114 at Joint 4 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [9-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.09) 4- 5 Vert DL L/120 L/999(-0.09) 4- 5 Vert CR L/240 L/612(-0.18) 4- 5 Horz LL 0.75in ( 0.01) @Jt 5 Horz CR 1.25in ( 0.01) @Jt 5 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-10-00 -1-06-00 9-06-01 3 BC 5-00-00 0 9-06-01 3 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: J06 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341949 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 4x6 4x4 = 5x7 1.5x3 4x6 4x12 1-6-0 2- 1 3- 1 1 - 1 0 1- 8 - 1 3 1- 1 0 - 1 4 6- 0 - 9 1 5-9-1 5-9-1 2 5-9-1 11-6-1 3 4 5-9-1 5-9-1 5 5-3-9 11-0-9 6 5-8 11-6-1 11-6-1 4.5/12 4.5/12 Truss Weight = 80.4 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard BB 2x6 DFL 1800/1.8 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.30 Max CSI in BC PANEL 5 - 6 0.19 Max CSI in Web 1 - 5 0.63 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 468 1606 0.30 2- 3 54 339 0.17 BC OH- 4 4 0 0.00 4- 5 118 335 0.16 5- 6 1542 697 0.19 Web 1- 4 322 791 0.12 1- 5 1432 330 0.63 2- 5 182 281 0.06 2- 6 558 1206 0.58 3- 6 143 171 0.04 BBK 3- 6 262 640 0.01 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 4 01-12 863 59 05-08 01-08 DFL 625 6 11-05-05 673 57 01-08 HGR DFL 1750 Max Horiz = -22 / +135 at Joint 4 Max Horiz = -22 / +135 at Joint 6 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [11-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.05) 5- 6 Vert DL L/120 L/999(-0.03) 4- 5 Vert CR L/240 L/999(-0.08) 4- 5 Horz LL 0.75in ( 0.01) @Jt 3 Horz CR 1.25in ( 0.01) @Jt 3 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-07-00 -1-06-00 11-06-01 4 BC 5-10-00 0 11-00-09 3 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Jnt3(01-08,00-09), Jnt6(02-07,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: J07 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341950 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 4x6 4x4 = 5x7 1.5x3 4x6 4x12 1-6-0 2- 1 4- 8 - 1 0 1- 8 - 1 3 1- 1 0 - 1 4 6- 9 - 9 1 6-9-1 6-9-1 2 6-9-1 13-6-1 3 4 6-9-1 6-9-1 5 6-3-9 13-0-9 6 5-8 13-6-1 13-6-1 4.5/12 4.5/12 Truss Weight = 92.6 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard BB 2x6 DFL 1800/1.8 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.64 Max CSI in BC PANEL 5 - 6 0.27 Max CSI in Web 1 - 5 0.88 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 620 2209 0.64 2- 3 66 432 0.24 BC OH- 4 4 0 0.00 4- 5 137 367 0.21 5- 6 2136 881 0.27 Web 1- 4 357 896 0.13 1- 5 1997 474 0.88 2- 5 218 334 0.07 2- 6 712 1700 0.36 3- 6 195 238 0.06 BBK 3- 6 293 770 0.02 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 4 01-12 981 67 05-08 01-08 DFL 625 6 13-05-05 793 65 01-08 HGR DFL 1750 Max Horiz = -22 / +156 at Joint 4 Max Horiz = -22 / +156 at Joint 6 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [13-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.10) 5- 6 Vert DL L/120 L/999(-0.05) 4- 5 Vert CR L/240 L/999(-0.15) 4- 5 Horz LL 0.75in ( 0.01) @Jt 3 Horz CR 1.25in ( 0.02) @Jt 3 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-04-00 -1-06-00 13-06-01 4 BC 6-11-00 0 13-00-09 3 ------- Web Bracing -- CLR ----------- Single: 2- 6 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt3(01-08,00-09), Jnt6(02-07,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: J08 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341951 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 4x6 4x5 = 5x7 1.5x3 5x5 = 4x12 1-6-0 2- 1 5- 5 - 1 0 1- 8 - 1 3 1- 1 0 - 1 4 7- 6 - 9 1 7-9-1 7-9-1 2 7-9-1 15-6-1 3 4 7-9-1 7-9-1 5 7-3-9 15-0-9 6 5-8 15-6-1 15-6-1 4.5/12 4.5/12 Truss Weight = 104.1 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL #2 1-5 2-6 BB 2x6 DFL 1800/1.8 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.72 Max CSI in BC PANEL 5 - 6 0.36 Max CSI in Web 2 - 6 0.55 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 771 2936 0.72 2- 3 75 530 0.29 BC OH- 4 4 0 0.00 4- 5 156 396 0.26 5- 6 2853 1060 0.36 Web 1- 4 388 1004 0.13 1- 5 2686 618 0.51 2- 5 246 385 0.08 2- 6 862 2311 0.55 3- 6 254 317 0.08 BBK 3- 6 315 901 0.03 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 4 01-12 1100 75 05-08 01-08 DFL 625 6 15-05-05 914 73 01-08 HGR DFL 1750 Max Horiz = -22 / +177 at Joint 4 Max Horiz = -22 / +177 at Joint 6 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [15-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.17) 5- 6 Vert DL L/120 L/999(-0.09) 4- 5 Vert CR L/240 L/720(-0.25) 4- 5 Horz LL 0.75in ( 0.02) @Jt 3 Horz CR 1.25in ( 0.02) @Jt 3 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-06-00 -1-06-00 15-06-01 5 BC 8-00-00 0 15-00-09 3 ------- Web Bracing -- CLR ----------- Single: 2- 6 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt3(01-08,00-09), Jnt6(02-07,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: J09 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341952 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 4x7 5x5 = 5x5 = 5x7 1.5x3 5x6 = 4x12 1-6-0 2- 1 6- 2 - 1 0 1- 8 - 1 3 1- 1 0 - 1 4 8- 3 - 9 1 8-9-1 8-9-1 2 8-9-1 17-6-1 4 5 8-9-1 8-9-1 6 8-3-9 17-0-9 7 5-8 17-6-1 3 17-6-1 4.5/12 4.5/12 Truss Weight = 118.3 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL #2 1-6 2-7 BB 2x6 DFL 1800/1.8 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.98 Max CSI in BC PANEL 6 - 7 0.48 Max CSI in Web 2 - 7 0.90 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 900 3735 0.98 2- 3 75 648 0.38 3- 4 85 435 0.28 BC OH- 5 4 0 0.00 5- 6 175 420 0.33 6- 7 3643 1213 0.48 Web 1- 5 412 1109 0.14 1- 6 3447 742 0.66 2- 6 268 438 0.08 2- 7 983 2975 0.90 4- 7 327 425 0.10 BBK 4- 7 332 1045 0.03 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 5 01-12 1219 83 05-08 01-08 DFL 625 7 17-05-05 1034 81 01-08 HGR DFL 1750 Max Horiz = -22 / +198 at Joint 5 Max Horiz = -22 / +198 at Joint 7 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [17-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/740(-0.28) 6- 7 Vert DL L/120 L/999(-0.15) 5- 6 Vert CR L/240 L/494(-0.42) 5- 6 Horz LL 0.75in ( 0.02) @Jt 4 Horz CR 1.25in ( 0.03) @Jt 4 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-03-00 -1-06-00 17-06-01 5 BC 9-01-00 0 17-00-09 3 ------- Web Bracing -- CLR ----------- Single: 2- 7 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt4(01-08,00-09), Jnt7(02-07,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: J10 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341953 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x7 8x8 = 5x7 1.5x3 10x10 = 4x12 1-6-0 2- 1 6- 1 1 - 1 0 1- 8 - 1 3 1- 1 0 - 1 4 9- 0 - 9 1 9-9-1 9-9-1 2 9-9-1 19-6-1 3 4 9-9-1 9-9-1 5 9-3-9 19-0-9 6 5-8 19-6-1 19-6-1 4.5/12 4.5/12 Truss Weight = 136.7 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL #2 1-5 2x4 DFL 1800/1.8 2-6 BB 2x6 DFL 1800/1.8 Member Forces Summary Max CSI in TC PANEL 1 - 2 1.00 Max CSI in BC PANEL 5 - 6 0.57 Max CSI in Web 2 - 6 0.94 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 1016 4652 1.00 2- 3 102 770 0.47 BC OH- 4 4 0 0.00 4- 5 194 442 0.36 5- 6 4545 1347 0.57 Web 1- 4 432 1217 0.15 1- 5 4326 855 0.83 2- 5 285 488 0.09 2- 6 1091 3749 0.94 3- 6 404 542 0.13 BBK 3- 6 339 1187 0.03 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 4 01-12 1338 91 05-08 01-08 DFL 625 6 19-05-05 1154 88 01-08 HGR DFL 1750 Max Horiz = -22 / +219 at Joint 4 Max Horiz = -22 / +219 at Joint 6 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [19-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/542(-0.43) 5- 6 Vert DL L/120 L/999(-0.22) 4- 5 Vert CR L/240 L/361(-0.64) 4- 5 Horz LL 0.75in ( 0.03) @Jt 3 Horz CR 1.25in ( 0.05) @Jt 3 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-02-00 -1-06-00 19-06-01 8 BC 6-09-00 0 19-00-09 4 ------- Web Bracing -- CLR ----------- Single: 2- 6 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt2(-00-08,01-06), Jnt3(01-08,00-09), Jnt5(00-03,-00-07), Jnt6(02-07,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: J11 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341954 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x8 4x4 = 4x6 5x7 5x7 1.5x4 6x8 5x8-18 4x4 = 4x12 1-6-0 2- 1 7- 8 - 1 0 1- 8 - 1 3 1- 1 0 - 1 4 9- 9 - 9 1 7-2-0 7-2-0 2 7-2-0 14-4-1 4 7-2-0 21-6-1 5 6 7-2-0 7-2-0 7 7-2-0 14-4-1 9 6-8-8 21-0-9 10 5-8 21-6-1 3 8 21-6-1 4.5/12 4.5/12 Truss Weight = 151.0 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL #2 1-7 2-9 BB 2x6 DFL 1800/1.8 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.98 Max CSI in BC PANEL 8 - 9 0.57 Max CSI in Web 4 - 10 0.91 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 1032 4707 0.98 2- 3 1079 4702 0.92 3- 4 1088 4525 0.80 4- 5 85 632 0.27 BC OH- 6 4 0 0.00 6- 7 199 471 0.23 7- 8 4584 1316 0.55 8- 9 4619 1307 0.57 9-10 4609 1346 0.51 Web 1- 6 445 1364 0.16 1- 7 4366 860 0.84 2- 7 277 743 0.09 2- 9 315 315 0.27 4- 9 274 0 0.11 4-10 1111 3855 0.91 5-10 232 223 0.07 BBK 5-10 377 1251 0.03 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 6 01-12 1457 99 05-08 01-09 DFL 625 10 21-05-05 1274 96 01-08 HGR DFL 1750 Max Horiz = -22 / +240 at Joint 6 Max Horiz = -22 / +240 at Joint 10 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [21-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/640(-0.40) 7- 9 Vert DL L/120 L/999(-0.20) 7- 9 Vert CR L/240 L/424(-0.60) 7- 9 Horz LL 0.75in ( 0.05) @Jt 5 Horz CR 1.25in ( 0.07) @Jt 5 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-01-00 -1-06-00 21-06-01 7 BC 7-05-00 0 21-00-09 4 ------- Web Bracing -- CLR ----------- Single: 4-10 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(00-08,0), Jnt5(01-08,00-09), Jnt7(-00-04,-00-01), Jnt10(02-07,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 4 Truss: J12 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341955 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x10 4x4 = 4x6 4x12 5x7 1.5x4 6x10 5x8-18 4x4 = 4x12 1-6-0 2- 1 8- 5 - 1 0 1- 8 - 1 3 1- 1 0 - 1 4 10 - 6 - 9 1 7-10-0 7-10-0 2 7-10-0 15-8-1 4 7-10-0 23-6-1 5 6 7-10-0 7-10-0 7 7-10-0 15-8-1 9 7-4-8 23-0-9 10 5-8 23-6-1 3 8 23-6-1 4.5/12 4.5/12 Truss Weight = 170.4 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-7 2x4 DFL #2 2-9 4-10 BB 2x6 DFL 1800/1.8 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.99 Max CSI in BC PANEL 8 - 9 0.67 Max CSI in Web 4 - 10 0.90 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 1220 5716 0.99 2- 3 1259 5624 0.88 3- 4 1265 5399 0.60 4- 5 98 718 0.32 BC OH- 6 4 0 0.00 6- 7 218 504 0.27 7- 8 5576 1532 0.61 8- 9 5620 1526 0.67 9-10 5520 1539 0.61 Web 1- 6 474 1483 0.18 1- 7 5335 1036 0.47 2- 7 300 814 0.10 2- 9 311 391 0.11 4- 9 304 0 0.12 4-10 1280 4660 0.90 5-10 276 282 0.08 BBK 5-10 396 1379 0.03 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 6 01-12 1577 107 05-08 01-11 DFL 625 10 23-05-05 1394 104 01-08 HGR DFL 1750 Max Horiz = -22 / +261 at Joint 6 Max Horiz = -22 / +261 at Joint 10 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [23-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/547(-0.51) 7- 9 Vert DL L/120 L/999(-0.26) 7- 9 Vert CR L/240 L/362(-0.77) 7- 9 Horz LL 0.75in ( 0.06) @Jt 5 Horz CR 1.25in ( 0.09) @Jt 5 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-06-00 -1-06-00 23-06-01 8 BC 8-02-00 0 23-00-09 4 ------- Web Bracing -- CLR ----------- Single: 2- 9 ------- Web Bracing -- CLR ----------- Double: 4-10 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(01-08,0), Jnt4(02-02,00-13), Jnt5(01-08,00-09), Jnt7(-01-03,-00-07), Jnt10(02-07,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J13 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341956 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 6x12 4x4 = 4x64x12 5x7 1.5x4 6x10 5x8-18 4x4 = 5x12 1-6-0 2- 1 9- 2 - 1 0 1- 8 - 1 3 1- 1 0 - 1 4 11 - 3 - 9 1 8-4-3 8-4-3 2 8-4-3 16-8-6 4 8-9-11 25-6-1 5 6 8-4-3 8-4-3 7 8-4-3 16-8-6 9 8-4-3 25-0-9 10 5-8 25-6-1 3 8 25-6-1 4.5/12 4.5/12 Truss Weight = 190.6 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-7 4-10 2x4 DFL #2 2-9 BB 2x6 DFL 1800/1.8 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.98 Max CSI in BC PANEL 8 - 9 0.77 Max CSI in Web 4 - 10 0.77 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 1393 6641 0.98 2- 3 1494 6819 0.85 3- 4 1496 6543 0.66 4- 5 106 791 0.41 BC OH- 6 4 0 0.00 6- 7 235 537 0.30 7- 8 6489 1733 0.68 8- 9 6540 1729 0.77 9-10 6711 1793 0.72 Web 1- 6 500 1595 0.19 1- 7 6221 1197 0.54 2- 7 323 900 0.11 2- 9 453 314 0.10 4- 9 321 0 0.13 4-10 1515 5767 0.77 5-10 336 347 0.10 BBK 5-10 401 1477 0.04 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 6 01-12 1696 115 05-08 01-13 DFL 625 10 25-05-05 1514 112 01-08 HGR DFL 1750 Max Horiz = -22 / +282 at Joint 6 Max Horiz = -22 / +282 at Joint 10 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [25-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/462(-0.66) 7- 9 Vert DL L/120 L/910(-0.33) 7- 9 Vert CR L/240 L/306(-0.99) 7- 9 Horz LL 0.75in ( 0.08) @Jt 5 Horz CR 1.25in ( 0.12) @Jt 5 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 2-11-00 -1-06-00 25-06-01 10 BC 8-11-00 0 25-00-09 3 ------- Web Bracing -- CLR ----------- Single: 2- 9 4-10 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(02-08,0), Jnt4(02-02,00-13), Jnt5(01-08,00-09), Jnt7(-01-03,-00-07), Jnt10(02-07,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J14 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341957 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 7x8-18= 4x4 = 5x5 = 5x12 5x7 2x4 7x8-18 = 7x8-18 = 4x4 = 5x12 1-6-0 2- 1 9- 1 1 - 1 0 1- 8 - 1 3 1- 1 0 - 1 4 12 - 0 - 9 1 9-0-3 9-0-3 2 9-0-3 18-0-6 4 9-5-11 27-6-1 5 6 9-0-3 9-0-3 7 9-0-3 18-0-6 9 9-0-3 27-0-9 10 5-8 27-6-1 3 8 27-6-1 4.5/12 4.5/12 Truss Weight = 208.4 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 2400/2.0 2x6 DFL 1800/1.8 3-5 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-7 4-10 2x4 DFL #2 2-9 SB 2x4 DFL Standard BB 2x6 DFL 1800/1.8 Member Forces Summary Max CSI in TC PANEL 1 - 2 1.00 Max CSI in BC PANEL 8 - 9 0.88 Max CSI in Web 4 - 10 0.77 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.08 1- 2 1591 7724 1.00 2- 3 1694 7918 0.86 3- 4 1701 7661 0.81 4- 5 123 893 0.48 BC OH- 6 4 0 0.00 6- 7 253 571 0.35 7- 8 7566 1959 0.83 8- 9 7613 1949 0.88 9-10 7802 2015 0.84 Web 1- 6 527 1708 0.21 1- 7 7264 1383 0.64 2- 7 345 966 0.11 2- 9 491 338 0.12 4- 9 346 0 0.14 4-10 1709 6737 0.77 5-10 390 435 0.12 BBK 5-10 419 1612 0.06 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 6 01-12 1816 123 05-08 01-15 DFL 625 10 27-05-05 1634 120 01-08 HGR DFL 1750 Max Horiz = -22 / +303 at Joint 6 Max Horiz = -22 / +303 at Joint 10 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [27-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/379(-0.86) 7- 9 Vert DL L/120 L/746(-0.44) 7- 9 Vert CR L/240 L/251(-1.30) 7- 9 Horz LL 0.75in ( 0.10) @Jt 5 Horz CR 1.25in ( 0.15) @Jt 5 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 2-11-00 -1-06-00 27-06-01 11 BC 9-07-00 0 27-00-09 4 ------- Web Bracing -- CLR ----------- Single: 2- 9 ------- Web Bracing -- CLR ----------- Double: 4-10 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(00-08,0), Jnt4(02-02,00-13), Jnt5(01-08,00-09), Jnt7(-00-04,-00-01), Jnt8(-00-04,00-11), Jnt10(02-07,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J15 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341958 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x8-18 5x5 = 4x4 = 4x8 5x5 = 5x10 1.5x3 2x4 7x8-18 = 5x5 =6x16-18S5 4x4 = 5x5 = 5x8-18 1-6-0 10 - 1 0 - 9 1- 8 - 1 3 1- 1 0 - 1 4 12 - 9 - 7 1 5-10-5 5-10-5 2 5-10-5 11-8-10 3 5-10-5 17-7-0 5 5-10-5 23-5-5 6 6-0-5 29-5-10 7 8 5-10-5 5-10-5 9 5-10-5 11-8-10 10 5-10-5 17-7-0 12 5-10-5 23-5-5 13 6-0-5 29-5-10 14 4 11 29-5-10 4.5/12 4.5/12 Truss Weight = 219.8 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-9 6-14 2x4 DFL #2 2-10 Member Forces Summary Max CSI in TC PANEL 3 - 4 1.00 Max CSI in BC PANEL 11 - 12 0.96 Max CSI in Web 2 - 10 0.52 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 1335 6137 0.53 2- 3 1832 9008 0.93 3- 4 1840 8979 1.00 4- 5 1844 8813 0.84 5- 6 1386 6169 0.56 6- 7 88 111 0.20 7-OH 0 12 0.00 BC OH- 8 4 0 0.00 8- 9 256 597 0.17 9-10 6055 1763 0.69 10-11 8882 2191 0.94 11-12 8913 2186 0.96 12-13 8906 2162 0.93 13-14 6107 1616 0.58 14-OH 0 9 0.00 Web 1- 8 532 1842 0.22 1- 9 5704 1155 0.50 2- 9 368 1277 0.15 2-10 2723 486 0.52 3-10 190 560 0.07 3-12 331 341 0.22 5-12 217 0 0.09 5-13 640 2639 0.52 6-13 759 76 0.33 6-14 1501 5739 0.47 7-14 155 284 0.06 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 8 01-12 1918 10 05-08 02-01 DFL 625 14 29-01-14 1777 123 05-14 01-14 DFL 625 Max Horiz = -22 / +323 at Joint 8 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [29-05-10] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/393(-0.88) 10-12 Vert DL L/120 L/781(-0.45) 10-12 Vert CR L/240 L/261(-1.33) 10-12 Horz LL 0.75in ( 0.11) @Jt14 Horz CR 1.25in ( 0.16) @Jt14 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 2-09-00 -1-06-00 29-05-10 13 BC 7-10-00 0 29-05-10 5 ------- Web Bracing -- CLR ----------- Single: 5-13 6-14 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(00-08,0), Jnt6(01-03,00-07), Jnt9(-00-04,-00-01), Jnt11(-00-01,00-04), Jnt14(-00-08,0) EngDrwg: 2021r5RGT_Eng 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J16 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341959 TID:199573 Date:08 / 08 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 7x8-18= 4x4 = 5x5 = 4x8 4x12 2x4 2x6 2x4 7x8-18 = 7x8-18 =4x4 = 5x5 = 4x12 2x4 1-6-0 11 - 7 - 9 1- 8 - 1 3 1- 1 0 - 1 4 13 - 6 - 7 1 7-3-9 7-3-9 2 7-3-9 14-7-2 3 7-3-9 21-10-11 5 7-4-9 29-3-4 6 2-2-6 31-5-10 7 8 7-3-9 7-3-9 9 7-3-9 14-7-2 11 7-3-9 21-10-11 12 7-4-9 29-3-4 13 2-2-6 31-5-10 14 4 10 31-5-10 4.5/12 4.5/12 Truss Weight = 226.7 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 2x6 DFL 2400/2.0 10-14 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-9 5-13 2x4 DFL #2 2-11 3-12 Member Forces Summary Max CSI in TC PANEL 2 - 3 0.96 Max CSI in BC PANEL 9 - 10 0.79 Max CSI in Web 3 - 12 0.65 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 1461 6933 0.75 2- 3 1727 8807 0.96 3- 4 1107 6042 0.62 4- 5 1127 5953 0.68 5- 6 105 150 0.62 6- 7 49 239 0.61 7-OH 0 12 0.00 BC OH- 8 4 0 0.00 8- 9 277 632 0.24 9-10 6827 1910 0.79 10-11 6839 1887 0.52 11-12 8692 2026 0.67 12-13 6005 1435 0.71 13-14 46 195 0.59 14-OH 0 9 0.00 Web 1- 8 524 1762 0.21 1- 9 6485 1268 0.57 2- 9 354 1119 0.13 2-11 1796 235 0.34 3-11 107 208 0.04 3-12 687 2620 0.65 5-12 458 0 0.20 5-13 1302 5562 0.61 6-13 456 1163 0.14 7-14 453 109 0.20 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 8 01-12 1853 0 05-08 02-00 DFL 625 13 29-03-04 3050 215 05-14 02-13 DFL 715 14 31-01-14 71 967 01-10 01-08 DFL 670 Max Horiz = -22 / +344 at Joint 8 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [31-05-10] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/400(-0.87) 9-11 Vert DL L/120 L/804(-0.43) 9-11 Vert CR L/240 L/267(-1.31) 9-11 Horz LL 0.75in ( 0.09) @Jt13 Horz CR 1.25in ( 0.13) @Jt13 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 2-08-00 -1-06-00 31-05-10 14 BC 8-04-00 0 31-05-10 5 ------- Web Bracing -- CLR ----------- Single: 3-12 5-13 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(00-08,0), Jnt5(02-02,00-13), Jnt7(0,01-01), Jnt9(-00-04,-00-01), Jnt10(-00-04,00-11), Jnt13(-02-02,-00-13) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J17 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341960 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 7x8-18= 4x4 = 4x6 4x8 4x12 2x4 2x4 2x4 7x8-18 = 8x18-18 4x6 4x12 2x4 1-6-0 12 - 4 - 9 1- 8 - 1 3 1- 1 0 - 1 4 14 - 3 - 7 1 7-3-9 7-3-9 2 7-3-9 14-7-2 3 7-3-9 21-10-11 5 7-4-9 29-3-4 6 4-2-6 33-5-10 7 8 7-3-9 7-3-9 9 7-3-9 14-7-2 10 7-3-9 21-10-11 11 7-4-9 29-3-4 12 4-2-6 33-5-10 13 4 33-5-10 4.5/12 4.5/12 Truss Weight = 242.5 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 2x6 DFL 2400/2.0 10-13 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-9 5-12 2x4 DFL #2 2-10 3-11 Member Forces Summary Max CSI in TC PANEL 2 - 3 0.98 Max CSI in BC PANEL 9 - 10 0.81 Max CSI in Web 3 - 11 0.64 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 1459 6979 0.76 2- 3 1737 8921 0.98 3- 4 1105 6182 0.63 4- 5 1125 6093 0.70 5- 6 114 159 0.57 6- 7 37 163 0.56 7-OH 0 12 0.00 BC OH- 8 4 0 0.00 8- 9 292 664 0.25 9-10 6886 1941 0.81 10-11 8770 2051 0.66 11-12 6139 1384 0.65 12-13 33 93 0.54 13-OH 0 9 0.00 Web 1- 8 523 1770 0.21 1- 9 6529 1265 0.57 2- 9 355 1123 0.13 2-10 1862 225 0.35 3-10 105 203 0.04 3-11 672 2560 0.64 5-11 467 4 0.20 5-12 1262 5710 0.63 6-12 388 936 0.12 7-13 141 143 0.06 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 8 01-12 1860 0 05-08 02-00 DFL 625 12 29-03-04 2534 182 05-14 02-06 DFL 715 13 33-01-14 101 271 01-10 01-08 DFL 670 Max Horiz = -22 / +365 at Joint 8 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [33-05-10] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/394(-0.89) 10-11 Vert DL L/120 L/789(-0.44) 9-10 Vert CR L/240 L/263(-1.33) 9-10 Horz LL 0.75in ( 0.09) @Jt12 Horz CR 1.25in ( 0.14) @Jt12 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 2-08-00 -1-06-00 33-05-10 15 BC 8-11-00 0 33-05-10 5 ------- Web Bracing -- CLR ----------- Single: 3-11 5-12 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(00-08,0), Jnt5(02-02,00-13), Jnt9(-00-04,-00-01), Jnt10(00-08,-01-06), Jnt12(-02-02,-00-13) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J18 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341961 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x10 4x4 = 5x7 5x5 = 6x10-18 2x4 4x10 2x4 2x4 6x10 4x4 = 5x8-18 5x7 8x16 8x8 = 1-6-0 13 - 1 - 9 1- 8 - 1 3 1- 1 0 - 1 4 15 - 0 - 7 1 7-3-9 7-3-9 2 7-3-9 14-7-2 3 7-3-9 21-10-11 5 7-6-5 29-5-0 6 2-10-7 32-3-77 3-2-3 35-5-108 9 7-3-9 7-3-9 10 7-3-9 14-7-2 11 7-3-9 21-10-11 13 7-4-9 29-3-4 14 6-2-6 35-5-10 15 4 12 35-5-10 4.5/12 4.5/12 Truss Weight = 263.4 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 2x6 DFL 2400/2.0 4-8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-10 5-14 2x4 DFL #2 2-11 3-13 7-15 Member Forces Summary Max CSI in TC PANEL 2 - 3 0.97 Max CSI in BC PANEL 14 - 15 0.98 Max CSI in Web 14 - 7 0.90 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 1211 5745 0.88 2- 3 1226 6419 0.97 3- 4 390 2655 0.37 4- 5 410 2566 0.32 5- 6 5584 1234 0.62 6- 7 5418 1122 0.61 7- 8 61 46 0.07 8-OH 0 12 0.00 BC OH- 9 4 0 0.00 9-10 308 697 0.22 10-11 5654 1727 0.67 11-12 6279 1594 0.71 12-13 6314 1584 0.71 13-14 2587 720 0.47 14-15 555 2867 0.98 15-OH 0 9 0.00 Web 1- 9 477 1540 0.18 1-10 5356 1030 0.47 2-10 309 902 0.11 2-11 658 111 0.12 3-11 208 12 0.08 3-13 883 3565 0.89 5-13 769 66 0.34 5-14 1646 7577 0.84 6-14 335 919 0.11 7-14 701 3288 0.90 7-15 2651 497 0.51 8-15 104 205 0.04 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 9 01-12 1629 0 05-08 01-12 DFL 625 14 29-03-04 3868 264 05-14 03-05 DFL 781 15 35-01-14 72 1081 01-10 01-08 DFL 625 Max Horiz = -22 / +386 at Joint 9 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [35-05-10] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/505(-0.69) 10-11 Vert DL L/120 L/999(-0.35) 10-11 Vert CR L/240 L/336(-1.04) 10-11 Horz LL 0.75in ( 0.07) @Jt14 Horz CR 1.25in ( 0.10) @Jt14 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-05-00 -1-06-00 35-05-10 12 BC 5-05-00 0 35-05-10 7 ------- Web Bracing -- CLR ----------- Single: 3-13 5-14 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(01-08,0), Jnt5(01-03,00-07), Jnt10(-01-03,-00-07), Jnt15(-00-08,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J19 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341962 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x10 4x4 = 5x6 = 5x5 = 6x10-18 4x7 4x12 4x5 =2x4 2x4 4x5 = 6x10 4x4 = 7x8-18 = 5x6 = 6x10-18 4x7 8x12 1-6-0 13 - 1 0 - 9 1- 8 - 1 3 1- 1 0 - 1 4 15 - 9 - 7 1 7-3-9 7-3-9 2 7-3-9 14-7-2 3 7-3-9 21-10-11 5 7-4-9 29-3-4 6 3-11-11 33-2-15 7 4-2-11 37-5-10 9 10 7-3-9 7-3-9 12 7-3-9 14-7-2 13 7-3-9 21-10-11 15 7-4-9 29-3-4 16 3-11-11 33-2-15 17 4-2-11 37-5-10 18 4 8 11 14 37-5-10 4.5/12 4.5/12 Truss Weight = 280.8 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-12 5-16 2x4 DFL #2 2-13 3-15 6-17 Member Forces Summary Max CSI in TC PANEL 2 - 3 0.96 Max CSI in BC PANEL 16 - 17 0.95 Max CSI in Web 7 - 18 0.95 ...Mem... Ten Comp .CSI. TC OH- 1 69 0 0.11 1- 2 1222 5826 0.85 2- 3 1251 6587 0.96 3- 4 423 2906 0.38 4- 5 443 2816 0.42 5- 6 5294 1184 0.83 6- 7 2322 532 0.58 7- 8 16 75 0.10 8- 9 63 57 0.09 9-OH 0 12 0.00 BC OH-10 4 0 0.00 10-11 289 729 0.18 11-12 323 719 0.22 12-13 5735 1771 0.67 13-14 6460 1651 0.72 14-15 6481 1634 0.71 15-16 2843 764 0.51 16-17 1041 5312 0.95 17-18 472 2327 0.14 18-OH 0 9 0.00 Web 1-10 479 1555 0.19 1-12 5433 1041 0.47 2-12 311 918 0.11 2-13 741 77 0.14 3-13 201 24 0.08 3-15 875 3486 0.87 5-15 740 59 0.32 5-16 1633 7546 0.83 6-16 481 1741 0.21 6-17 2749 596 0.52 7-17 286 1022 0.12 7-18 2167 423 0.95 9-18 113 216 0.05 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 10 01-12 1644 0 05-08 01-12 DFL 625 16 29-03-04 3543 243 05-14 03-09 DFL 667 18 37-01-14 37 602 01-10 01-08 DFL 625 Max Horiz = -22 / +407 at Joint 10 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [37-05-10] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/493(-0.71) 12-13 Vert DL L/120 L/984(-0.36) 12-13 Vert CR L/240 L/328(-1.06) 12-13 Horz LL 0.75in ( 0.07) @Jt16 Horz CR 1.25in ( 0.10) @Jt16 Ohng CR 2L/240 2L/999(-0.01) 1- 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-04-00 -1-06-00 37-05-10 13 BC 3-10-00 0 37-05-10 11 ------- Web Bracing -- CLR ----------- Single: 3-15 5-16 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(01-08,0), Jnt5(01-03,00-07), Jnt7(02-02,00-13), Jnt12(-01-03,-00-07), Jnt14(-00-04,00-11), Jnt16(-01-03,-00-07), Jnt18(-02-08,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J20 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341963 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 7x8-18= 4x4 = 4x64x12 5x7 1.5x4 6x10 5x8-18 4x4 = 5x12 2- 1 9- 2 - 1 0 1- 8 - 1 3 1- 1 0 - 1 4 11 - 3 - 9 1 8-4-3 8-4-3 2 8-4-3 16-8-6 4 8-9-11 25-6-1 5 6 8-4-3 8-4-3 7 8-4-3 16-8-6 9 8-4-3 25-0-9 10 5-8 25-6-1 3 8 25-6-1 4.5/12 4.5/12 Truss Weight = 187.5 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-7 4-10 2x4 DFL #2 2-9 BB 2x6 DFL 1800/1.8 Member Forces Summary Max CSI in TC PANEL 1 - 2 1.00 Max CSI in BC PANEL 8 - 9 0.77 Max CSI in Web 4 - 10 0.77 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 1517 6660 1.00 2- 3 1494 6827 0.84 3- 4 1496 6551 0.66 4- 5 106 792 0.41 BC OH- 6 4 0 0.00 6- 7 223 516 0.30 7- 8 6509 1871 0.68 8- 9 6561 1867 0.77 9-10 6719 1792 0.72 Web 1- 6 424 1433 0.17 1- 7 6241 1358 0.55 2- 7 353 903 0.11 2- 9 441 326 0.10 4- 9 323 0 0.13 4-10 1514 5773 0.77 5-10 334 347 0.10 BBK 5-10 401 1478 0.04 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 6 01-12 1535 89 05-08 01-10 DFL 625 10 25-05-05 1516 112 01-08 HGR DFL 1750 Max Horiz = -30 / +266 at Joint 6 Max Horiz = -30 / +266 at Joint 10 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [25-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/462(-0.66) 7- 9 Vert DL L/120 L/904(-0.34) 7- 9 Vert CR L/240 L/305(-0.99) 7- 9 Horz LL 0.75in ( 0.08) @Jt 5 Horz CR 1.25in ( 0.12) @Jt 5 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 2-11-00 0 25-06-01 10 BC 8-11-00 0 25-00-09 3 ------- Web Bracing -- CLR ----------- Single: 2- 9 4-10 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(00-08,0), Jnt4(02-02,00-13), Jnt5(01-08,00-09), Jnt7(-01-03,-00-07), Jnt10(02-07,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J21 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341964 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x8-18 4x6 4x4 = 4x8 6x10 5x7 1.5x4 6x10 7x8-18 = 4x6 4x4 = 4x12 2- 1 9- 1 1 - 1 0 1- 8 - 1 3 1- 1 0 - 1 4 12 - 0 - 9 1 6-9-2 6-9-2 2 6-9-2 13-6-5 3 7-1-4 20-7-9 5 6-10-8 27-6-1 6 7 6-9-2 6-9-2 8 6-9-2 13-6-5 10 6-9-2 20-3-7 11 6-9-2 27-0-9 12 5-8 27-6-1 4 9 27-6-1 4.5/12 4.5/12 Truss Weight = 200.9 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-8 5-12 BB 2x6 DFL 1800/1.8 Member Forces Summary Max CSI in TC PANEL 2 - 3 1.00 Max CSI in BC PANEL 10 - 11 0.90 Max CSI in Web 2 - 10 0.80 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 1493 6408 0.71 2- 3 1768 8362 1.00 3- 4 1460 6636 0.76 4- 5 1478 6537 0.77 5- 6 93 688 0.23 BC OH- 7 4 0 0.00 7- 8 233 546 0.23 8- 9 6304 1896 0.74 9-10 6320 1877 0.74 10-11 8264 2054 0.90 11-12 6491 1739 0.63 Web 1- 7 441 1571 0.19 1- 8 5980 1344 0.52 2- 8 384 1119 0.13 2-10 1827 328 0.80 3-10 150 291 0.04 3-11 535 1620 0.40 5-11 494 19 0.22 5-12 1479 5588 0.51 6-12 188 129 0.06 BBK 6-12 433 1543 0.05 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 7 01-12 1655 97 05-08 01-12 DFL 625 12 27-05-05 1636 120 01-08 HGR DFL 1750 Max Horiz = -30 / +287 at Joint 7 Max Horiz = -30 / +287 at Joint 12 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [27-06-01] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/434(-0.75) 8-10 Vert DL L/120 L/868(-0.38) 10-11 Vert CR L/240 L/289(-1.13) 10-11 Horz LL 0.75in ( 0.10) @Jt 6 Horz CR 1.25in ( 0.15) @Jt 6 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 2-11-00 0 27-06-01 11 BC 9-07-00 0 27-00-09 4 ------- Web Bracing -- CLR ----------- Single: 3-11 5-12 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(00-08,0), Jnt5(00-08,00-03), Jnt6(01-08,00-09), Jnt8(-01-03,-00-07), Jnt9(-00-04,00-11), Jnt12(02-07,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J22 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341965 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x8-18 5x5 = 4x4 = 5x5 =5x5 = 5x10 1.5x3 1.5x4 7x8-18 = 5x8-18 5x5 = 4x4 = 5x5 = 5x8-18 10 - 1 0 - 9 1- 8 - 1 3 1- 1 0 - 1 4 12 - 9 - 7 1 5-10-5 5-10-5 2 5-10-5 11-8-10 3 5-10-5 17-7-0 4 5-10-5 23-5-5 6 6-0-5 29-5-10 7 8 5-10-5 5-10-5 9 5-10-5 11-8-10 11 5-10-5 17-7-0 12 5-10-5 23-5-5 13 5-9-8 29-2-13 2-13 29-5-10 14 5 10 29-5-10 4.5/12 4.5/12 Truss Weight = 210.0 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-9 6-14 2x4 DFL #2 2-11 Member Forces Summary Max CSI in TC PANEL 3 - 4 1.00 Max CSI in BC PANEL 11 - 12 0.96 Max CSI in Web 4 - 13 0.52 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 1451 6157 0.54 2- 3 1943 9022 0.93 3- 4 1845 8988 1.00 4- 5 1366 6174 0.46 5- 6 1386 6137 0.56 6- 7 88 111 0.20 7-OH 0 12 0.00 BC OH- 8 4 0 0.00 8- 9 244 576 0.17 9-10 6072 1895 0.69 10-11 6078 1874 0.68 11-12 8926 2248 0.96 12-13 8915 2162 0.93 13-14 6112 1617 0.58 14-OH 0 9 0.00 Web 1- 8 457 1680 0.20 1- 9 5726 1308 0.50 2- 9 408 1283 0.15 2-11 2682 481 0.51 3-11 188 549 0.06 3-12 328 345 0.22 4-12 217 0 0.09 4-13 673 2643 0.52 6-13 760 84 0.33 6-14 1501 5744 0.47 7-14 155 284 0.06 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 8 01-12 1757 0 01-08 HGR DFL 625 14 29-01-14 1778 123 05-14 01-14 DFL 625 Max Horiz = -30 / +308 at Joint 8 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [29-05-10] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/393(-0.88) 11-12 Vert DL L/120 L/778(-0.45) 11-12 Vert CR L/240 L/261(-1.33) 11-12 Horz LL 0.75in ( 0.11) @Jt14 Horz CR 1.25in ( 0.16) @Jt14 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 2-09-00 0 29-05-10 12 BC 7-10-00 0 29-05-10 5 ------- Web Bracing -- CLR ----------- Single: 4-13 6-14 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(00-08,0), Jnt6(01-03,00-07), Jnt9(-00-04,-00-01), Jnt14(-00-08,0) EngDrwg: 2021r5RGT_Eng 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J23 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341966 TID:199573 Date:08 / 08 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 7x8-18= 4x4 = 4x6 5x7 4x12 2x4 2x4 2x4 7x8-18 = 7x8-18 =4x4 = 4x6 4x12 2x4 11 - 7 - 9 1- 8 - 1 3 1- 1 0 - 1 4 13 - 6 - 7 1 7-2-12 7-2-12 2 7-2-12 14-5-9 3 7-2-12 21-8-5 5 7-3-12 29-0-1 6 2-5-9 31-5-10 7 8 7-2-12 7-2-12 9 7-2-12 14-5-9 11 7-2-12 21-8-5 12 7-3-12 29-0-1 13 2-5-9 31-5-10 14 4 10 31-5-10 4.5/12 4.5/12 Truss Weight = 222.8 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 2x6 DFL 2400/2.0 10-14 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-9 5-13 2x4 DFL #2 2-11 3-12 Member Forces Summary Max CSI in TC PANEL 2 - 3 0.98 Max CSI in BC PANEL 9 - 10 0.78 Max CSI in Web 3 - 12 0.63 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 1563 6833 0.77 2- 3 1786 8670 0.98 3- 4 1125 5962 0.69 4- 5 1137 5815 0.65 5- 6 107 146 0.60 6- 7 41 213 0.59 7-OH 0 12 0.00 BC OH- 8 4 0 0.00 8- 9 265 610 0.23 9-10 6730 2027 0.78 10-11 6742 2004 0.51 11-12 8557 2086 0.65 12-13 5924 1407 0.68 13-14 44 167 0.57 14-OH 0 9 0.00 Web 1- 8 446 1587 0.19 1- 9 6390 1408 0.56 2- 9 385 1114 0.13 2-11 1723 221 0.33 3-11 109 197 0.05 3-12 722 2565 0.63 5-12 456 8 0.20 5-13 1277 5490 0.60 6-13 432 1085 0.13 7-14 354 80 0.15 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 8 01-12 1678 0 01-08 HGR DFL 625 13 29-00-01 2879 204 05-14 02-11 DFL 715 14 31-01-14 59 781 01-10 01-08 DFL 670 Max Horiz = -30 / +329 at Joint 8 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [31-05-10] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/411(-0.84) 9-11 Vert DL L/120 L/822(-0.42) 11-12 Vert CR L/240 L/274(-1.26) 11-12 Horz LL 0.75in ( 0.09) @Jt13 Horz CR 1.25in ( 0.13) @Jt13 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 2-09-00 0 31-05-10 13 BC 8-04-00 0 31-05-10 5 ------- Web Bracing -- CLR ----------- Single: 3-12 5-13 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(00-08,0), Jnt5(02-02,00-13), Jnt9(-00-04,-00-01), Jnt10(-00-04,00-11), Jnt13(-02-02,-00-13) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J24 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341967 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 7x8-18 = 4x4 = 4x6 5x7 4x12 2x4 2x4 2x4 7x8-18 = 4x4 = 6x16-18S5 4x6 6x10 2x4 12 - 4 - 9 1- 8 - 1 3 1- 1 0 - 1 4 14 - 3 - 7 1 7-2-12 7-2-12 2 7-2-12 14-5-9 3 7-2-12 21-8-5 5 7-3-12 29-0-1 6 4-5-9 33-5-10 7 8 7-2-12 7-2-12 9 7-2-12 14-5-9 10 7-2-12 21-8-5 12 7-3-12 29-0-1 13 4-5-9 33-5-10 14 4 11 33-5-10 4.5/12 4.5/12 Truss Weight = 235.7 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-9 5-13 2x4 DFL #2 2-10 3-12 Member Forces Summary Max CSI in TC PANEL 2 - 3 1.00 Max CSI in BC PANEL 11 - 12 0.97 Max CSI in Web 3 - 12 0.61 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 1562 6871 0.78 2- 3 1786 8748 1.00 3- 4 1133 6119 0.71 4- 5 1146 5972 0.68 5- 6 114 195 0.57 6- 7 41 161 0.56 7-OH 0 12 0.00 BC OH- 8 4 0 0.00 8- 9 280 643 0.24 9-10 6781 2060 0.78 10-11 8602 2119 0.95 11-12 8636 2109 0.97 12-13 6070 1381 0.90 13-14 32 81 0.57 14-OH 0 9 0.00 Web 1- 8 445 1594 0.19 1- 9 6427 1407 0.56 2- 9 386 1124 0.13 2-10 1759 199 0.33 3-10 105 208 0.04 3-12 714 2489 0.61 5-12 478 15 0.21 5-13 1285 5649 0.61 6-13 387 933 0.12 7-14 125 154 0.05 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 8 01-12 1686 0 01-08 HGR DFL 625 13 29-00-01 2480 179 05-14 02-08 DFL 667 14 33-01-14 128 226 01-10 01-08 DFL 625 Max Horiz = -30 / +350 at Joint 8 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [33-05-10] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/393(-0.88) 9-10 Vert DL L/120 L/786(-0.44) 10-12 Vert CR L/240 L/262(-1.32) 10-12 Horz LL 0.75in ( 0.10) @Jt13 Horz CR 1.25in ( 0.14) @Jt13 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 2-09-00 0 33-05-10 13 BC 8-11-00 0 33-05-10 5 ------- Web Bracing -- CLR ----------- Single: 3-12 5-13 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(00-08,0), Jnt5(02-02,00-13), Jnt9(-00-04,-00-01), Jnt11(-00-01,00-04), Jnt13(-01-03,-00-07) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J25 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341968 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x10 4x4 = 5x6 = 5x5 = 6x10-18 2x4 4x10 2x4 2x4 5x10 4x4 = 5x8-18 5x6 = 8x12 8x8 = 13 - 1 - 9 1- 8 - 1 3 1- 1 0 - 1 4 15 - 0 - 7 1 7-2-13 7-2-13 2 7-2-13 14-5-9 3 7-2-13 21-8-6 5 7-3-12 29-0-2 6 3-1-4 32-1-67 3-4-4 35-5-108 9 7-2-13 7-2-13 10 7-2-13 14-5-9 11 7-2-13 21-8-6 13 7-3-12 29-0-2 14 6-5-8 35-5-10 15 4 12 35-5-10 4.5/12 4.5/12 Truss Weight = 255.9 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 2x6 DFL 2400/2.0 4-8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-10 5-14 2x4 DFL #2 2-11 3-13 7-15 Member Forces Summary Max CSI in TC PANEL 2 - 3 1.00 Max CSI in BC PANEL 14 - 15 0.97 Max CSI in Web 14 - 7 0.91 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 1308 5672 0.91 2- 3 1276 6340 1.00 3- 4 402 2647 0.42 4- 5 415 2500 0.28 5- 6 5452 1261 0.62 6- 7 5296 1151 0.61 7- 8 61 48 0.07 8-OH 0 12 0.00 BC OH- 9 4 0 0.00 9-10 296 675 0.22 10-11 5584 1839 0.65 11-12 6202 1644 0.69 12-13 6237 1634 0.69 13-14 2580 719 0.46 14-15 563 2788 0.97 15-OH 0 9 0.00 Web 1- 9 397 1367 0.16 1-10 5288 1166 0.46 2-10 339 900 0.11 2-11 610 118 0.11 3-11 208 4 0.08 3-13 923 3498 0.86 5-13 761 77 0.33 5-14 1677 7444 0.81 6-14 325 895 0.11 7-14 701 3199 0.91 7-15 2572 502 0.49 8-15 106 207 0.04 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 9 01-12 1456 0 01-08 HGR DFL 625 14 29-00-02 3769 257 05-14 03-03 DFL 781 15 35-01-14 65 969 01-10 01-08 DFL 625 Max Horiz = -30 / +370 at Joint 9 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [35-05-10] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/516(-0.67) 10-11 Vert DL L/120 L/999(-0.34) 10-11 Vert CR L/240 L/343(-1.01) 10-11 Horz LL 0.75in ( 0.06) @Jt14 Horz CR 1.25in ( 0.10) @Jt14 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-06-00 0 35-05-10 11 BC 5-06-00 0 35-05-10 7 ------- Web Bracing -- CLR ----------- Single: 3-13 5-14 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(01-08,0), Jnt5(01-03,00-07), Jnt10(-01-03,-00-07), Jnt15(-00-08,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: J26 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341969 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 5x10 4x4 = 5x6 = 5x5 = 6x10-18 4x7 4x10 4x5 = 2x4 2x4 4x5 = 6x10 4x4 = 5x8-18 5x6 = 6x10-18 4x7 8x10 13 - 1 0 - 9 1- 8 - 1 3 1- 1 0 - 1 4 15 - 9 - 7 1 7-2-12 7-2-12 2 7-2-12 14-5-9 3 7-2-12 21-8-5 5 7-3-12 29-0-1 6 4-1-5 33-1-6 7 4-4-4 37-5-10 9 10 7-2-12 7-2-12 12 7-2-12 14-5-9 13 7-2-12 21-8-5 15 7-3-12 29-0-1 16 4-1-5 33-1-6 17 4-4-4 37-5-10 18 4 8 11 14 37-5-10 4.5/12 4.5/12 Truss Weight = 273.9 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x6 DFL 1800/1.8 BC 2x6 DFL 1800/1.8 Webs 2x4 DFL Standard 2x6 DFL 1800/1.8 1-12 5-16 2x4 DFL #2 2-13 3-15 6-17 Member Forces Summary Max CSI in TC PANEL 2 - 3 0.98 Max CSI in BC PANEL 16 - 17 0.96 Max CSI in Web 7 - 18 0.90 ...Mem... Ten Comp .CSI. TC OH- 1 5 0 0.00 1- 2 1319 5751 0.88 2- 3 1301 6502 0.98 3- 4 436 2894 0.43 4- 5 449 2747 0.38 5- 6 5153 1206 0.81 6- 7 2200 536 0.56 7- 8 14 78 0.11 8- 9 64 60 0.12 9-OH 0 12 0.00 BC OH-10 4 0 0.00 10-11 278 708 0.18 11-12 311 698 0.22 12-13 5663 1884 0.66 13-14 6377 1702 0.72 14-15 6397 1683 0.70 15-16 2831 760 0.51 16-17 1059 5169 0.96 17-18 472 2199 0.15 18-OH 0 9 0.00 Web 1-10 400 1382 0.17 1-12 5363 1176 0.47 2-12 341 916 0.11 2-13 688 85 0.13 3-13 200 15 0.08 3-15 914 3416 0.84 5-15 732 68 0.32 5-16 1658 7401 0.81 6-16 471 1699 0.20 6-17 2737 601 0.52 7-17 283 980 0.12 7-18 2047 423 0.90 9-18 116 219 0.05 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 10 01-12 1471 0 01-08 HGR DFL 625 16 29-00-01 3479 239 05-14 03-08 DFL 667 18 37-01-14 58 551 01-10 01-08 DFL 625 Max Horiz = -30 / +391 at Joint 10 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [37-05-10] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/505(-0.69) 12-13 Vert DL L/120 L/999(-0.34) 12-13 Vert CR L/240 L/336(-1.03) 12-13 Horz LL 0.75in ( 0.07) @Jt16 Horz CR 1.25in ( 0.10) @Jt16 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 3-05-00 0 37-05-10 12 BC 3-11-00 0 37-05-10 11 ------- Web Bracing -- CLR ----------- Single: 3-15 5-16 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Jnt1(01-08,0), Jnt5(01-03,00-07), Jnt7(01-03,00-07), Jnt12(-01-03,-00-07), Jnt16(-01-03,-00-07), Jnt18(-01-08,0) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 105 Truss: PB1 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341970 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 3x4 = 1.5x3 3x4= 1.5x3 3x4 = 1.5x3 1.5x3 1.5x3 3x3 =1.5x3 1.5x3 1.5x3 1- 9 - 8 1-9 - 8 3- 3 - 9 15 1-6-15 1-6-15 1 3-2-9 4-9-8 2 4-0-0 8-9-8 3 4-0-0 12-9-8 4 3-2-9 16-0-1 5 1-6-15 17-7-0 1-6-15 1-6-15 1 3-2-9 4-9-8 7 4-0-0 8-9-8 10 2-11-15 11-9-7 12 1-0-1 12-9-8 13 3-2-9 16-0-1 5 1-6-15 17-7-0 6 8 9 11 14 17-7-0 4.5/12 -4.5/12 Truss Weight = 60.3 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 1.0 Lum 1.15 1.60 1.15 Total 36.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 20-00-00 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 0.6 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x4 DFL 1800/1.8 BC 2x4 DFL 1800/1.8 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 1 - 2 0.28 Max CSI in BC PANEL 1 - 6 0.10 Max CSI in Web 7 - 2 0.07 ...Mem... Ten Comp .CSI. TC 1- 2 108 37 0.28 2- 3 90 101 0.27 3- 4 89 102 0.27 4- 5 106 38 0.27 BC 1- 6 70 27 0.10 5-14 71 29 0.10 6- 7 70 27 0.08 7- 9 70 27 0.02 9-10 70 27 0.01 10-11 71 29 0.00 11-12 71 29 0.02 12-13 71 29 0.02 13-14 71 29 0.08 Web 2- 7 224 597 0.07 3-15 103 372 0.07 4-13 224 597 0.07 10-15 102 371 0.07 12-15 16 18 0.00 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 7 4-09-08 560 74 17-07-00 13 12-09-08 543 73 17-07-00 Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 5 39 6 17-07-00 (reduced) Max Horiz = -54 / +54 at Joint 10 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [8-09-08] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. This truss is not symmetric - proper orientation is critical. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.01) 1- 6 Vert DL L/120 L/999(-0.00) 1- 6 Vert CR L/240 L/999(-0.01) 1- 6 Horz LL 0.75in ( 0.00) @Jt 1 Horz CR 1.25in ( 0.00) @Jt 1 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-11-00 00-11 14-01-02 4 TC 2-00-00 14-01-02 29-02-14 2 BC 7-06-00 1-02-10 16-04-06 3 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 1 Truss: PB2 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341971 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 3x4 = 1.5x3 3x4= 1.5x3 3x4 = 1.5x3 1.5x3 1.5x3 2- 5 - 1 1 1-6-15 1-6-15 1 3-0-4 4-7-3 2 2-0-0 6-7-3 3 2-0-0 8-7-3 4 3-0-4 11-7-7 5 1-6-14 13-2-5 1-6-15 1-6-15 1 3-0-4 4-7-3 7 2-0-0 6-7-3 8 2-0-0 8-7-3 9 3-0-4 11-7-7 5 1-6-14 13-2-5 6 10 13-2-5 4.5/12 -4.5/12 Truss Weight = 38.4 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 1.0 Lum 1.15 1.60 1.15 Total 36.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 20-00-00 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 0.6 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x4 DFL 1800/1.8 BC 2x4 DFL 1800/1.8 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 1 - 2 0.14 Max CSI in BC PANEL 1 - 6 0.10 Max CSI in Web 7 - 2 0.05 ...Mem... Ten Comp .CSI. TC 1- 2 135 40 0.14 2- 3 83 50 0.13 3- 4 83 50 0.13 4- 5 135 40 0.14 BC 1- 6 68 57 0.10 5-10 68 57 0.10 6- 7 68 57 0.08 7- 8 68 57 0.01 8- 9 68 57 0.01 9-10 68 57 0.08 Web 2- 7 154 411 0.05 3- 8 52 188 0.02 4- 9 154 411 0.05 Reaction Summary Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 5 101 14 13-02-05 Max Horiz = -37 / +37 at Joint 8 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [6-07-03] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.01) 10- 5 Vert DL L/120 L/999(-0.00) 10- 5 Vert CR L/240 L/999(-0.01) 10- 5 Horz LL 0.75in ( 0.00) @Jt 5 Horz CR 1.25in ( 0.00) @Jt 5 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-07-00 00-11 13-01-11 4 TC 2-00-00 14-01-02 29-02-14 0 BC 5-04-00 1-02-10 11-11-12 3 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 2 Truss: PB3 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341972 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 3x4 = 1.5x3 3x4= 1.5x3 3x4 = 1.5x3 1.5x3 1.5x3 2- 5 - 1 1 1-6-15 1-6-15 1 3-0-4 4-7-3 2 2-0-0 6-7-3 3 2-0-0 8-7-3 4 3-0-4 11-7-7 5 1-6-14 13-2-5 1-6-15 1-6-15 1 3-0-4 4-7-3 7 2-0-0 6-7-3 8 2-0-0 8-7-3 9 3-0-4 11-7-7 5 1-6-14 13-2-5 6 10 13-2-5 2-Ply 4.5/12 -4.5/12 Truss Weight = 76.8 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 1.0 Lum 1.15 1.60 1.15 Total 36.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 2 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 20-00-00 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 0.6 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x4 DFL 1800/1.8 BC 2x4 DFL 1800/1.8 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 1 - 2 0.07 Max CSI in BC PANEL 1 - 6 0.05 Max CSI in Web 7 - 2 0.02 ...Mem... Ten Comp .CSI. TC 1- 2 135 40 0.07 2- 3 83 50 0.06 3- 4 83 50 0.06 4- 5 135 40 0.07 BC 1- 6 68 57 0.05 5-10 68 57 0.05 6- 7 68 57 0.04 7- 8 68 57 0.01 8- 9 68 57 0.01 9-10 68 57 0.04 Web 2- 7 154 411 0.02 3- 8 52 188 0.01 4- 9 154 411 0.02 Reaction Summary Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 5 101 14 13-02-05 Max Horiz = -37 / +37 at Joint 8 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [6-07-03] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. 2-PLY TRUSS Fastener Spacing Fasten each ply to the adjacent ply as follows(rows staggered): TC 2x4, 1-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c. BC 2x4, 1-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c. WB 2x4, 1-row(s) of 0.131" dia. x 3.0" Nails @ 9.0" o.c. Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 10- 5 Vert DL L/120 L/999(-0.00) 10- 5 Vert CR L/240 L/999(-0.00) 10- 5 Horz LL 0.75in ( 0.00) @Jt 5 Horz CR 1.25in ( 0.00) @Jt 5 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-07-00 00-11 13-01-11 4 BC 5-04-00 1-02-10 11-11-12 3 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 1 Truss: PB4 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341973 TID:199573 Date:08 / 07 / 23 Page:1 of 2 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 4x4 = 3x10 6x12 3x10 4x4 = 3x5 1.5x3 3x5 3- 3 - 9 2-11-6 2-11-6 1 2-11-11 5-11-0 2 2-10-8 8-9-8 3 2-10-8 11-8-0 4 2-11-11 14-7-11 5 2-11-6 17-7-0 2-11-6 2-11-6 1 2-11-11 5-11-0 7 2-10-8 8-9-8 9 2-10-8 11-8-0 11 2-11-11 14-7-11 5 2-11-6 17-7-0 6 8 10 12 17-7-0 4-Ply 4.5/12 -4.5/12 Truss Weight = 359.5 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 1.0 Lum 1.15 1.60 1.15 Total 36.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 4 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No Lu(max) = 20-00-00 ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 263.4 ft B = 132.8 ft M.R.H(h) = 20.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 0.6 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 8-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x10 DFL SS BC 2x4 DFL 1800/1.8 Webs 2x4 DFL Standard Member Forces Summary Max CSI in TC PANEL 1 - 2 0.02 Max CSI in BC PANEL 1 - 6 0.01 Max CSI in Web 7 - 2 0.59 ...Mem... Ten Comp .CSI. TC 1- 2 155 103 0.02 2- 3 93 137 0.02 3- 4 93 137 0.02 4- 5 103 147 0.02 BC 1- 6 52 61 0.01 5-12 52 61 0.01 6- 7 52 61 0.00 7- 8 52 61 0.00 8- 9 52 61 0.00 9-10 52 61 0.00 10-11 52 61 0.00 11-12 52 61 0.01 Web 2- 7 7527 3855 0.59 3- 9 157 203 0.01 4-11 2966 8144 0.23 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 6 3-07-04 117 184 17-07-00 7 5-11-00 3849 7506 17-07-00 9 8-09-08 206 154 17-07-00 11 11-08-00 8128 2956 17-07-00 Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 1- 5 1 0 17-07-00 (reduced) Max Horiz = -48 / +48 at Joint 9 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [8-09-08] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. (User-created load combinations exist on this truss.) 4-PLY TRUSS Fastener Spacing Fasten through all plys as follows (rows staggered): TC 2x10, 3-row(s) of Simpson SDS25600 Screws @ 24.0" o.c.** BC 2x4, 1-row(s) of Simpson SDS25600 Screws @ 24.0" o.c. WB 2x4, 1-row(s) of Simpson SDS25600 Screws @ 9.0" o.c. ** Use additional fasteners of the same type (u.n.o.) within +/-12" of the location(s) indicated (except where approved hangers are used with fasteners that transfer the load to all plies): TC:5-11-00, 3, TC:5-11-00, 4, TC:5-11-00, 2 TC:5-11-00, 8, TC:11-08-00, 3, TC:11-08-00, 6 TC:11-08-00, 2, TC:11-08-00, 1, TC:11-08-00, 9 Notes Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Lumber and plating have been applied symmetrically. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/360 L/999(-0.00) 12- 5 Vert DL L/120 L/999(-0.00) 12- 5 Vert CR L/240 L/999(-0.00) 12- 5 Horz LL 0.75in ( 0.00) @Jt 5 Horz CR 1.25in ( 0.00) @Jt 5 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 4-07-00 00-11 17-06-05 5 BC 6-02-00 2-07-00 15-00-00 3 Web Bracing -- None Plate offsets (X, Y): (None unless indicated below) Jnt1(0,00-02), Jnt2(0,02-07), Jnt4(0,02-07), Jnt5(0,00-02), Jnt7(0,-00-09), Jnt11(0,-00-09) EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 1 Truss: PB4 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341973 TID:199573 Date:08 / 07 / 23 Page:2 of 2 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 Loadcase -- 99000 Load Case 3 Dur Factors: 1.60 1.60 Domain Type ------------Name------------ Dir plf-beg plf-end -x-beg-- -x-end-- -y-beg-- -y-end-- Top Dead TCDL Vert 20.00 20.00 0 8-09-08 0 3-03-09 Bottom Dead BCDL Vert 2.00 2.00 0 17-07-00 0 0 Top Dead TCDL Vert 20.00 20.00 8-09-08 17-07-00 3-03-09 0 Domain Type ------------Name------------ Dir Lbs -x-loc-- -y-loc-- EQ plf sum DL plf Top Live User-Defined @ 90 Deg Vert 4000 5-11-00 1-09-11 1250.0 12.5 Top Live User-Defined @ 90 Deg Vert 4000 11-08-00 1-09-11 1250.0 12.5 Loadcase -- 99005 Load Case 4 Dur Factors: 1.60 1.60 Domain Type ------------Name------------ Dir plf-beg plf-end -x-beg-- -x-end-- -y-beg-- -y-end-- Top Dead TCDL Vert 20.00 20.00 0 8-09-08 0 3-03-09 Bottom Dead BCDL Vert 2.00 2.00 0 17-07-00 0 0 Top Dead TCDL Vert 20.00 20.00 8-09-08 17-07-00 3-03-09 0 Domain Type ------------Name------------ Dir Lbs -x-loc-- -y-loc-- EQ plf sum DL plf Top Live Steeple @ 90 Deg Vert -5200 5-11-00 1-09-11 -1625.0 12.5 Top Live Steeple @ 90 Deg Vert 6000 11-08-00 1-09-11 1875.0 12.5 Loadcase -- 99006 Load Case 5 Dur Factors: 1.60 1.60 Domain Type ------------Name------------ Dir plf-beg plf-end -x-beg-- -x-end-- -y-beg-- -y-end-- Top Dead TCDL Vert 20.00 20.00 0 8-09-08 0 3-03-09 Bottom Dead BCDL Vert 2.00 2.00 0 17-07-00 0 0 Top Dead TCDL Vert 20.00 20.00 8-09-08 17-07-00 3-03-09 0 Domain Type ------------Name------------ Dir Lbs -x-loc-- -y-loc-- EQ plf sum DL plf Top Live Steeple @ 90 Deg Vert -3200 5-11-00 1-09-11 -1000.0 12.5 Top Live Steeple @ 90 Deg Vert -3200 11-08-00 1-09-11 -1000.0 12.5 Loadcase -- 99007 Load Case 6 Dur Factors: 1.60 1.60 Domain Type ------------Name------------ Dir plf-beg plf-end -x-beg-- -x-end-- -y-beg-- -y-end-- Top Dead TCDL Vert 20.00 20.00 0 8-09-08 0 3-03-09 Bottom Dead BCDL Vert 2.00 2.00 0 17-07-00 0 0 Top Dead TCDL Vert 20.00 20.00 8-09-08 17-07-00 3-03-09 0 Domain Type ------------Name------------ Dir Lbs -x-loc-- -y-loc-- EQ plf sum DL plf Top Live Steeple @ 90 Deg Vert -8000 5-11-00 1-09-11 -2500.0 12.5 Top Live Steeple @ 90 Deg Vert -2500 11-08-00 1-09-11 -781.3 12.5 Loadcase -- 99008 Load Case 7 Dur Factors: 1.60 1.60 Domain Type ------------Name------------ Dir plf-beg plf-end -x-beg-- -x-end-- -y-beg-- -y-end-- Top Dead TCDL Vert 20.00 20.00 0 8-09-08 0 3-03-09 Bottom Dead BCDL Vert 2.00 2.00 0 17-07-00 0 0 Top Dead TCDL Vert 20.00 20.00 8-09-08 17-07-00 3-03-09 0 Domain Type ------------Name------------ Dir Lbs -x-loc-- -y-loc-- EQ plf sum DL plf Top Live User-Defined @ 90 Deg Vert -2000 5-11-00 1-09-11 -625.0 12.5 Top Live User-Defined @ 90 Deg Vert 8500 11-08-00 1-09-11 2656.3 12.5 EngDrwg: 2021r5RGT_PS 2305309HWC - Rexburg 10-Ward LDS Chapel Qty: 16 Truss: TR 9 Customer: Headwaters Construction Co Truss Mfr. Contact: Michael Jackson SID:0002341974 TID:199573 Date:08 / 07 / 23 Page:1 of 1 NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. Component Solutions Truss Studio V 2023.1.0.84 Typical plate: 1.5x3 3x7 3x4 =3x4 = 1x3 1x3 1x3 1x3 2x3= 1x3 1x3 1x3 1x3 1x3 1x3 1x3 12 - 0 - 0 12 - 0 - 0 1 7-6-14 7-6-14 2 7-6-14 15-1-12 3 4 15-1-12 15-1-12 11 5 6 7 8 9 10 Truss Weight = 215.0 lb Code/Design: IBC-2018/TPI-2014 PSF Live Dead Dur Factors TC 25.0 10.0 Live Wind Snow BC 0.0 10.0 Lum 1.15 1.60 1.15 Total 45.0 Plt 1.15 1.60 1.15 Spacing: 2-00-00 o.c. Plies: 1 Repetitive Member Increase: Yes Green Lumber: No Wet Service: No Fab Tolerance: 20% Creep (Kcr) = 2.0 OH Soffit Load: 2.0 psf -----------Snow Load Specs---------- ASCE7-16 Roof Snow (Pf) = 40.0 psf Risk Cat: III Terrain Cat: C Roof Exposure: Sheltered Thermal Condition: All Others(1.0) Unobstructed Slippery Roof: No Low-Slope Minimums(Pfmin): No Unbalanced Snow Loads: Yes Rain Surcharge: No Ice Dam Chk: No ----------Wind Load Specs---------- ASCE7-16 Wind Speed(V) = 112 mph Risk Cat: III Exposure Cat: C Bldg Dims: L = 0.0 ft B = 0.0 ft M.R.H(h) = 15.0 ft Kzt = 1.0 Bldg Enclosure: Enclosed Wind DL(psf): TC = 6.0 BC = 6.0 End Vertical Exposed: L = Yes R = Yes Wind Uplift Reporting: ASCE7 MWFRS C&C End Zone: 3-00-00 -------Additional Design Checks------ 10 psf Non-Concurrent BCLL: Yes 20 psf BC Limited Storage: Yes 200 lb BC Accessible Ceiling: Yes 300 lb TC Maintenance Load: Yes 2000 lb TC Safe Load: No Unbalanced TCLL: Yes Material Summary TC 2x4 DFL 1800/1.8 BC 2x4 DFL 1800/1.8 Webs 2x4 DFL Standard 2x4 DFL 1800/1.8 2-11 4-1 4-2 2x4 DFL #2 2-7 2x6 DFL 1800/1.8 11-3 Member Forces Summary Max CSI in TC PANEL 1 - 2 0.89 Max CSI in BC PANEL 4 - 5 0.04 Max CSI in Web 4 - 1 0.83 ...Mem... Ten Comp .CSI. TC OH- 1 0 0 0.00 1- 2 0 162 0.89 2- 3 0 162 0.88 3-OH 0 0 0.00 BC OH- 4 0 0 0.00 4- 5 290 418 0.04 5- 6 290 418 0.04 6- 7 290 418 0.04 7- 8 290 416 0.04 8- 9 290 416 0.04 9-10 290 416 0.04 10-11 290 416 0.04 11-OH 0 0 0.00 Web 1- 4 157 295 0.83 2- 4 535 541 0.20 2-11 536 546 0.20 3-11 159 298 0.34 Reaction Summary --------------Reaction Summary(Lbs)---------------- Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI 4 01-12 772 302 15-01-12 11 14-11-00 782 303 15-01-12 Reactions not shown: down < 400 and up < 150 ---- Reaction Summary (plf) ----- Jnt-Jnt React -Up- --Width- 4- 11 17 0 15-01-12 (reduced) Max Horiz = -351 / +351 at Joint 7 Loads Summary This truss has been designed for the effects of an unbalanced top chord live load occurring at [7-06-14] using a 1.00 Full and 0.00 Reduced load factor. See Loadcase Report for loading combinations and additional details. Notes Gable webs are attached with min. 1x3 20 ga.plates. The max.rake overhang = 1/2 the truss spacing. If this truss is exposed to wind loads perpendicular to the plane of the truss, it must be braced according to a standard detail matching the wind criteria shown, or according to the Construction Documents and/or BCSI - B3. Plates designed for Cq at 0.80 and Rotational Tolerance of 10.0 degrees Plates located at TC pitch breaks meet the prescriptive minimum size requirement to transfer unblocked diaphragm loads across those joints. Continuous Lateral Restraint (CLR) rows require diagonal bracing per D-WEBCLRBRACE. Alternatively, see D-WEBREINFORCE. Less than 0.25/12 pitch requires adequate drainage to prevent ponding. This truss is not symmetric - proper orientation is critical. Deflection Summary TrussSpan Limit Actual(in) Location Vert LL L/240 L/999(-0.00) 4- 5 Vert DL L/120 L/999(-0.00) 4- 5 Vert CR L/180 L/999(-0.00) 4- 5 Horz LL 0.75in ( 0.00) @Jt11 Horz CR 1.25in ( 0.00) @Jt11 Bracing Data Summary ------------Bracing Data------------ Chords; Sheathing required or bracing indicated: -------------Purlins------------ ---oc--- --From-- ---To--- #Bays TC 5-00-00 0 15-01-12 4 BC 7-06-00 0 15-01-12 3 ------- Web Bracing -- CLR ----------- Single: 4- 1 11- 3 ------- Web Bracing -- CLR ----------- Double: 4- 2 2-11 Continuous Restraint Bracing Req’d See BCSI–B3 3.0 Plate offsets (X, Y): (None unless indicated below) Component Solutions™ NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawin g indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the ”Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762 . All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gaug e plate, or "S# 18", which indicates a high tension 18 gauge plate. Simpson Strong-Tie CompanyThis detail is to be used only for the application and conditions indicated herein, and its suitability for any particular truss/project shall be verified (by others). This detail is not intended to supersede any project-specific details provided in the Construction Documents. Truss configurations shown are for illustration only. Refer to the truss design drawing(s) accompanyingthis detail for specific truss design information. Simpson Strong-Tie Inc. is not responsible for any deviations from this design. Date:Rev: 1 Pg. 1 of 1 PLY-TO-PLY CLUSTER FASTENING MINIMUM SPACING REQUIREMENTS FOR SDS SCREWS (0.25" dia.) TD-FRM-0006B USA 09/22/2020 2- Ply 2x Truss 3- Ply 2x Truss 4- Ply 2x Truss Notes: 1.For additional information about fastener spacing, refer to page 44 of C-F-2019TECHSUP, Simpson's Fastening Systems Technical Guide Catalog, and ESR 2236. 2. Main member penetration shall be a minimum of 6D=1.45" into the main member. See TDD for specified screw sizes. 3. All ply-to-ply connections with Simpson SDS screws are designed assuming load is applied to the point side of the connection, U.N.O. on the TDD. 4. U.N.O., use additional fasteners as specified on TDD within +/- 12" of the location(s) indicated on the TDD. This detail provides minimum spacing requirements for SDS screws specified for ply-to-ply cluster fastening on the Truss Design Drawing (TDD). The total number of SDS screws required for any fastener cluster shall be as specified on the TDD. SDS fasteners placed in a fastener cluster shall be spaced according to Table 1 and Figure 3. Cluster fasteners shall be located within 12" on both sides of the location of the point load or hanger as shown in Figure 1. He a d s i d e Po i n t s i d e He a d s i d e Po i n t s i d e He a d s i d e Po i n t s i d e Table 1. Minimum spacing requirement of SDS screws Minimum end distance Minimum fastener spacing requirement Minimum dimensions (inches) DF, SP, SPF, HF 4 Minimum edge distance 1 1/2 Minimum spacing between staggered rows 1 1/2 Minimum spacing between non-staggered rows (perpendicular to grain)3 Minimum spacing between fasteners (parallel to grain)3 Figure 3. Spacing requirements for SDS screws 4" min. end distance 3" min. between non-staggered rows 3" min. between fasteners 1 1/2" Min. edge distance 1 1/2" min. stagger row 1 1/2" min. between staggered row 1 1/2" min. stagger row Figure 2. Load Applied to Outside Multi-Ply 2x Member Loaded on Point Side (three-ply assembly shown - other configurations similar) Load Loaded on Head Side (three-ply assembly shown - other configurations similar) Load Multi-ply member SDS screws - See fastener schedule on TDD for total number of cluster fasteners required. Simpson Hanger (HUS shown) Figure 1. Maximum Fastener spacing from Point Load 12" max. 1 1/2" min.CL Install half the total number of cluster fasteners specified on the TDD on each side of the point load location as shown. Component Solutions™ NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawin g indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the ”Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762 . All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gaug e plate, or "S# 18", which indicates a high tension 18 gauge plate. Simpson Strong-Tie CompanyThis detail is to be used only for the application and conditions indicated herein, and its suitability for any particular truss/project shall be verified (by others). This detail is not intended to supersede any project-specific details provided in the Construction Documents. Truss configurations shown are for illustration only. Refer to the truss design drawing(s) accompanyingthis detail for specific truss design information. Simpson Strong-Tie Inc. is not responsible for any deviations from this design. 15-5-12 14-0-12 12-3-8 DIAGONAL BRACING @ MID-SPAN 2 DIAGONAL BRACING @ 1/3 POINTS 2 MAXIMUM STUD LENGTH 3 WITHOUT BRACE Date:Rev:Pg. 1 of 1 GABLE STUD BRACING DETAIL - 90 MPH (NOMINAL), 115 MPH (ULTIMATE) TD-GBL-0002B 05/12/2014 B DETAIL LIMITATIONS: Max. Mean Roof Height: 30' Category: II Exposure: B or C Load Duration Factor: 1.6 Wind Speed: 90 mph Nominal Wind Speed Equivalent Nail Dimension 16d = 3.5" x 0.162" 10d = 3" x 0.148" 8d = 2.5" x 0.131" Nominal 90 mph (Ultimate) (115 mph) NOTES: 1. This detail provides bracing/reinforcement options for the gable studs to resist the out-of-plane wind loading. Refer to the individual truss design drawing for bracing/reinforcement requirements for resisting the vertical (in-plane) loads assumed in the design of the gable end frame. Additional bracing/reinforcement at the end of the building and/or at the gable end wall may be required. Refer to the Building Designer/Construction Documents for all gable end frame and roof system bracing requirements. For additional information, see BCSI-B3. 2. This detail does not apply to structural gables. 3. Connection requirements between the gable end frame and the wall to be specified by the Building Designer. 4. The gable end frame must match the profile of the adjacent trusses. Do not use a gable end frame with a flat bottom chord next to trusses with sloped bottom chords, such as scissor or vaulted trusses.GABLE END WITH STUD BRACING/REINFORCEMENT A A Diagonal Bracing @ 4'-0" O.C. Max.Gable Stud Bracing (24" O.C. Max) B B C C *Diagonal braces not shown for clarity. See Section A-A. 1. L- and Scab Reinforcements shall be minimum 2x4 stud grade and must be a minimum of 90% of the gable stud length. Fasten the reinforcement member to the gable stud with 10d nails @ 6" o.c. 2. Attach horizontal reinforcing member at mid-span (or 1/3 points as required) of the longest stud and install diagonal bracing @ 4' o.c. (max) as shown in Section A-A. 3. Tabulated maximum stud lengths are based on components and cladding wind pressures using the wind design parameters listed in the detail limitations. Gable stud deflection criteria is L/240. SECTION B-B SECTION C-C GABLE STUD 10d nails @ 6" o.c. L-REINF. GABLE STUD SCAB REINF. 10d nails @ 6" o.c. NOTE: Diagonal braces over 6'-3" require a 2x4 T-brace attached to one narrow edge. Diagonal braces over 12'-6" require 2x4s attached on both narrow edges. The braces must cover 90% of the diagonal brace and shall be fastened to the narrow edge with 10d nails at 6" o.c. (min. 3" end distance). When attached on both narrow edges, stagger the nails on each side by 3". Min. 2x6 Min. 2x4 Fasten L-reinforcement members together with 16d nails @ 6" O.C. 2x6 Diagonal Brace (Approx. 45-degrees to roof diaphragm) Gable Stud Fasten diagonal brace to gable stud with 4-16d nails 2-10d nails into top reinf. member (Typ. ea stud) 4-10d nails into bottom reinf. member (Typ. ea stud)Bracing at 1/3 points as required (See Table) SECTION A-A End Wall Roof Sheathing 5-8d nails connecting sheathing to blocking (Typ.) Min. 2x4 #2 blocking between first 2 trusses (min) as shown. Toe-nail blocking to trusses with 2-10d nails at each end. 2x6 diagonal brace at 48" O.C. (max). Attach to gable stud with 4-16d nails and to blocking with 5-10d nails. Horizontal L-reinforcement (located at mid-span or 1/3-points of longest stud as required per table.) 2-10d Toe-nails (Typ.) Trusses @ 24" O.C. Max. MINIMUM GABLE STUD SIZE, SPECIES & GRADE MAX. GABLE STUD SPACING 2X4 SPF STUD or STANDARD 12" O.C.5-1-12 9-0-12 SCAB REINFORCEMENT 1 10-3-12 10-3-12 16" O.C.4-8-4 8-3-0 9-4-8 9-4-8 24" O.C.4-1-0 7-0-0 8-2-4 8-2-4 L- REINFORCEMENT 1 Component Solutions™ NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawin g indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the ”Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762 . All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gaug e plate, or "S# 18", which indicates a high tension 18 gauge plate. Simpson Strong-Tie CompanyThis detail is to be used only for the application and conditions indicated herein, and its suitability for any particular truss/project shall be verified (by others). This detail is not intended to supersede any project-specific details provided in the Construction Documents. Truss configurations shown are for illustration only. Refer to the truss design drawing(s) accompanyingthis detail for specific truss design information. Simpson Strong-Tie Inc. is not responsible for any deviations from this design. Date:Rev:Pg. 1 of 1 INDIVIDUAL WEB REINFORCEMENT DETAIL D-WEBREINFORCE 06/11/2014 A NOTES: 1. This detail provides web reinforcement options that may be used as an alternative to continuous lateral restraint (CLR) when installing CLRs in combination with diagonal bracing is not practical or desired. 2. Refer to the truss design drawing for web lateral restraint requirements. A on the truss design drawing indicates that continuous lateral restraint is required at the locations shown (either at the midpoint or 1/3-points of the web member). Refer to the tables below for acceptable web reinforcement options that may be used in place of one or two rows of CLR. 3. This detail may not be used to substitute CLRs for T-, L-, I- or scab reinforcements that are specified on the truss design drawing. 4. T-, L-, I- and scab web reinforcements must be the same or better species and grade of the web member as indicated on the truss design drawing. 5. All reinforcements must extend to within 6'' of each end of the web member. 6. This detail does not apply to single-ply webs that exceed 14' in length. T- Reinforcement (I-Reinforcement similar) Add member to both edges for I-Reinforcement Web Member (Typ.) L- Reinforcement Scab Reinforcement 1 Row of CLR @ Web Mid-point 2 Rows of CLRs @ Web 1/3 points Nail Dimension 16d = 3.5" x 0.131" 10d = 3" x 0.120" 2x4 T-L-Scab I- Reinforcement-to-Web Connection Requirements Web Member Size WEB REINFORCEMENT OPTIONS FOR SINGLE-PLY TRUSSES 1 Specified Web Member Lateral Restraint (CLRs) Acceptable Web Reinforcement Substitutions - Type & Size 1 Row @ Mid-point 2 Row @ 1/3-points 2x4 2x4 2x4 2x4 --- 2x6 2x6 2x6 2x6 --- 2x8 2x8 2x8 2x8 ---16d gun nails @ 6" on-center 2x6 2x8 No substitutions allowed 2-2x4 2-2x6 2-2x8 2x4 T-L-Scab I- Reinforcement-to-Web Connection Requirements Web Member Size WEB REINFORCEMENT OPTIONS FOR 2-PLY TRUSSES 2 Specified Web Member Lateral Restraint (CLRs) Acceptable Web Reinforcement Substitutions - Type & Size 1 Row @ Mid-point 2 Row @ 1/3-points 2x4 2x4 2x4 --- 2x6 2x6 2x6 --- 2x8 2x8 2x8 ---16d gun nails @ 6" on-center 2x6 2x8 No substitutions allowed 2-2x4 2-2x6 2-2x8 --- --- --- 1. The maximum allowable web length for single-ply trusses is 14'. 2. For 2-ply trusses, the reinforcement must be nailed to both plies of the web with the nailing pattern specified in the table. 3. For the scab reinforcement, 2 rows of 10d gun nails @ 6" o.c may be used in place of 16d gun nails for attaching the reinforcement to the web. 4. For I-reinforcement, attach each 2x_member to opposite edges of the web using the nailing pattern specified in the table. Component Solutions™ NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawin g indicates acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the ”Important Information & General Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762 . All connector plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gaug e plate, or "S# 18", which indicates a high tension 18 gauge plate. Simpson Strong-Tie CompanyThis detail is to be used only for the application and conditions indicated herein, and its suitability for any particular truss/project shall be verified (by others). This detail is not intended to supersede any project-specific details provided in the Construction Documents. Truss configurations shown are for illustration only. Refer to the truss design drawing(s) accompanyingthis detail for specific truss design information. Simpson Strong-Tie Inc. is not responsible for any deviations from this design. Date:Rev:Pg. 1 of 1 LATERAL RESTRAINT & DIAGONAL BRACING DETAILS FOR WEB MEMBERS 05/24/2021 A WEB MEMBERS WITH LATERAL RESTRAINT 2 rows of CLR @ 1/3-points 1 row of CLR @ mid-points Note: Not all truss members shown for clarity. Overlap ends of CLRs at least one truss spacing or use splice detail (see Detail 1) Section A-A Detail 1 - CLR Splice Min. 2'-long 2x_ scab block centered over the CLR splice and web. Attach to CLR with min. 8-10d nails on each side of splice. Web CLR splice CLR Detail 3 - Diagonal Bracing for 2 Rows of CLRs For webs with 2 rows of CLRs, diagonal bracing shall be installed using Option 3A or 3B. Attach diagonal braces to each truss with min. 2-10d nails. Option 3A Option 3B < 450 < 450 Detail 2 - Diagonal Bracing for 1 Row of CLRs For webs with one row of CLRs, diagonal bracing shall be installed using Option 2A or 2B. Attach diagonal braces to each truss with min. 2-10d nails. Option 2A Option 2B <450 <450 D-WEBCLRBRACE This detail provides information for laterally restraining and bracing web members to prevent lateral buckling using continuous lateral restraints (CLRs) in combination with diagonal bracing. In addition to the CLRs indicated on the truss design drawing, diagonal bracing must be installed as indicated in this detail and BSCI-B3. See WEBREINFORCE for web reinforcement options that may be used as an alternative to this detail when installing CLRs and diagonal bracing is not practical or desired. Properly attached full-length sheathing satisfies (may replace) any bracing requirements specified for end vertical webs. Refer to the Construction Documents for additional Min. 2x4x12' CLRs installed on web members where indicated on the truss design drawing. Attach CLRs to each web with min. 2-10d nails < 20' between diagonal braces Install 2x4 diagonal bracing at each end and at every 20' along the length of the CLRs. See Diagonal Bracing Details 2 & 3. DETAIL LIMITATIONS: 1. Restraint and Bracing Material min. 2x4 stress graded lumber. 2. This detail does not address permanent building stability bracing to resist lateral forces acting on the building. 3. This detail shall not supersede any project-specific truss member permanent bracing design for the roof framing structural system. Nail Dimensions: 10d = 3" x 0.128" 4. This detail is not applicable for trusses with spacing greater than 2' o.c. bracing requirements. For trusses with spacing greater than 2' o.c., refer to BCSI-B10.