Loading...
HomeMy WebLinkAboutREDLINED PLANS - 22-00642 - 859 S Yellowstone Hwy Suite 2701 - Henry's Fork Plaza Office SuitesAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Don Allen Don.Allen@rexburg.org 208-372-2174 Description : RPRHNRFA010270 - Spa and Office Suites Address : RPRHNRFA010270 Application Type : Document Filename : Henry's Fork Plaza Spas and Suites.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G1.1 Free text Cody Jones : Building Open 1 Need Envelope COMM check or a prescriptive insulation formed signed. Stairways or ramps if needed will need to meet requirements of 1011, 1019 and 1012. Grading to slope 6" in first 10' from building. G1.1 Free text Cody Jones : Building Open 1 Snow loads Roof -35 Ground - 50 Wind-115 Seismic- D Risk category II G1.1 Free text Cody Jones : Building Open 1 Plan review for shell of building only. SD1.1 Free text Cody Jones : Building Open 2 As per table 602, due to separation distance to lot line a one hour wall is required for exterior walls on both sides. As per table 705.8 only 10% of wall can have openings. SD1.1 Free text Cody Jones : Building Open 2 Landings at door and cross slope of sidewalks not to exceed 2%. # 22-00642 New Commercial Building Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 08.31.2022 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A1.1 Free text Cody Jones : Building Open 3 Doors to meet egress width and requirements. A3.1 Free text Cody Jones : Building Open 6 Will need stamped engineered truss plans that are also approved by building design professional. A3.1 Free text Cody Jones : Building Open 6 All concealed spaces will need fire blocked/draft stopped per section 718. Draft stopping shall subdivide attics into areas no greater then 3000 square feet. (718.4). A3.1 Free text Cody Jones : Building Open 6 Need documentation showing anchorage to concrete as per section 1901.3 S1.1 Free text Cody Jones : Building Open 7 As per city ordinance top horizontal bar in foundation needs to be in the top 6" of wall. Report Date: 08.31.2022 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org) AREA MAP PROJECT SITE HENRY'S FORK PLAZA 859 SOUTH YELLOWSTONE REXBURG, ID 83440 LOT 27 HENRY'S FORK PLAZA S YELL O W ST O N E H W Y MI K A N D R LOT 27 DRAWING INDEX IBC 2018 ANALYSIS TYPE OF CONST. OCCUPANCY GROUP ALLOWABLE BLDG. SQFT ALLOWABLE BLDG. HT. ALLOWABLE BLDG. STORIES ACTUAL SQ FT MAIN LEVEL = ACTUAL BLDG. HT. ACTUAL BLDG. STORIES OCCUPANCY LOAD V-A 'B' NON SPRINKLED 18,000 SQFT 50' 3 3,660 SQFT NON SPRINKLED 3,660 SQFT < 18,000 = ACCEPTABLE 20' -1" 1 24 *PROVIDE DRINKIMG FOUNTAIN STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : OF 8/24/2022 11:57:20 AM S:\Drawings\923 - Stevens Const Co Spas & Suites\BIM\Spas and Suites(Recovery).rvt G1.1 CO V E R S H E E T 923 HE N R Y ' S F O R K S P A & O F F I C E S U I T E S Issue Date HJF RM RE X B U R G ID A H O REXBURG IDAHO HENRY'S FORK SPA & OFFICE SUITES G1.1 COVER SHEET SD1.1 SITE PLAN - LAYOUT A1.1 MAIN FLOOR PLAN A1.2 ROOF PLAN A2.1 EXTERIOR ELEVATIONS A3.1 BUILDING SECTIONS S1.1 FOOTING AND FOUNDATION PLAN GENERAL ARCHITECTURAL STRUCTURAL SITE Need Envelope COMM check or a prescriptive insulation formed signed. Stairways or ramps if needed will need to meet requirements of 1011, 1019 and 1012. Grading to slope 6" in first 10' from building. Snow loads Roof -35 Ground - 50 Wind-115 Seismic- D Risk category II Plan review for shell of building only. As per table 602, due to separation distance to lot line a one hour wall is required for exterior walls on both sides. As per table 705.8 only 10% of wall can have openings. Landings at door and cross slope of sidewalks not to exceed 2%. A2.1 3 A2.1 2 A2.1 4 A2.1 1 A A3.1 42 ' - 0 " 90' - 0" 30' - 0"30' - 0"30' - 0" 12 ' - 5 1 / 2 " 11 ' - 6 1 / 2 " 18 ' - 0 " 18 ' - 0 " 11 ' - 6 1 / 2 " 12 ' - 5 1 / 2 " 42 ' - 0 " 6' - 0"31' - 0"16' - 0"31' - 0"6' - 0" 6' - 2 1/2"6' - 10 1/2"3' - 10"7' - 1"13' - 0"6' - 1"3' - 10"6' - 1"13' - 0"7' - 1"3' - 10"6' - 10 1/2"6' - 2 1/2" 1 2A AA A A B A A B A A A3A A B A3.1 STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF 8/24/2022 11:57:18 AM S:\Drawings\923 - Stevens Const Co Spas & Suites\BIM\Spas and Suites(Recovery).rvt A1.1 MA I N F L O O R P L A N 923 HE N R Y ' S F O R K S P A & O F F I C E S U I T E S Issue Date HJF RM RE X B U R G ID A H O 0 SCALE:1/4" = 1'-0" MAIN FLOOR PLAN NORTH Doors to meet egress width and requirements. A2.1 3 A2.1 2 A2.1 4 A2.1 1 A A3.1 RIDGEVALLEYRI D G E RI D G ERIDGERIDGEVALLEYRI D G EVALLEYVALLEY2' - 0" 2' - 0 " 2' - 0 " 2' - 0 " 6" / 1 2 " 6" / 12" 6" / 1 2 " 6" / 12" 6" / 12" 6" / 12" 6" / 12"6" / 12" 2' - 0 " B A3.1 6' - 0 " 3' - 0" 3' - 0 " 3' - 0 " 6' - 0"3' - 0" 3' - 0 " RIDGE VENT ICE AND WATER SHIELD ASPHALT SHINGLES ASPHALT SHINGLES ASPHALT SHINGLES ASPHALT SHINGLES ICE AND WATER SHIELD STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF 8/24/2022 11:57:18 AM S:\Drawings\923 - Stevens Const Co Spas & Suites\BIM\Spas and Suites(Recovery).rvt A1.2 RO O F P L A N 923 HE N R Y ' S F O R K S P A & O F F I C E S U I T E S Issue Date HJF RM RE X B U R G ID A H O 0 SCALE:1/4" = 1'-0" ROOF PLAN NORTH GENERAL NOTES 1.ALUMINUM FASICA AND SOFFIT 2.WINDOWS TO BE VINYL LOW "E" WINDOWS 3.35 YR OR BETTER ASPHALT SHINGLE 4.GABLE VENTS elev100' -0" MAIN FLOOR PLAN elev110' -0" ROOF PLAN elev95' -9 3/4" FOOTING & FOUNDATION A A3.1 6" 12" elev120' -0 29/32" RIDGE ELEVATION 3 2 11 elev100' -0" MAIN FLOOR PLAN elev110' -0" ROOF PLAN elev95' -9 3/4" FOOTING & FOUNDATION A A3.1 STONE FINISH SIDING AS PER OWNER APPROVED 6" 12" 18' - 0 29/32" elev120' -0 29/32" RIDGE ELEVATION 4 2 3 4 11 elev100' -0" MAIN FLOOR PLAN elev110' -0" ROOF PLAN elev95' -9 3/4" FOOTING & FOUNDATION 6" 12" elev120' -0 29/32" RIDGE ELEVATION 2 3 11 elev100' -0" MAIN FLOOR PLAN elev110' -0" ROOF PLAN elev95' -9 3/4" FOOTING & FOUNDATION 6" 12" elev120' -0 29/32" RIDGE ELEVATION 2 3 11 STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF 8/24/2022 11:57:18 AM S:\Drawings\923 - Stevens Const Co Spas & Suites\BIM\Spas and Suites(Recovery).rvt A2.1 EX T E R I O R E L E V A T I O N S 923 HE N R Y ' S F O R K S P A & O F F I C E S U I T E S Issue Date HJF RM RE X B U R G ID A H O 0 SCALE:1/8" = 1'-0" NORTH SCALE:1/8" = 1'-0" SOUTH SCALE:1/8" = 1'-0" EAST SCALE:1/8" = 1'-0" WEST elev100' -0" MAIN FLOOR PLAN elev110' -0" ROOF PLAN elev95' -9 3/4" FOOTING & FOUNDATION PRE-MANUFACTURED TRUSS SYTEM R-49 BATT INSULATION R-21 BATT INSULATION MANUFACTURED STONE FINISH SIDING 6" 12" 3' - 0" CRAWL SPACE BEARING PONY WALL(S) FRAMING @ 24" O.C. (TYPICAL)11 7/8" FLOOR JOISTS TOUNGE AND GROOVE DECKING R-14 RIDGID INSULATION COMPACTED BACKFILL CONCRETE FOOTING CONCRETE FOUNDATION WALL SHEATHING 2 X 6 FRAMING AIR FILTRATION BARRIER CLASS C ASPHALT SHINGLES UNDERLAYMENT ROOF SHEATHING 2 X 8 SUB-FACIA STEEL FACIA ALUMINUM SOFFIT B A3.1 elev120' -0 29/32" RIDGE ELEVATION R-38 BATT INSULATION elev100' -0" MAIN FLOOR PLAN elev110' -0" ROOF PLAN elev95' -9 3/4" FOOTING & FOUNDATION A A3.1 elev120' -0 29/32" RIDGE ELEVATION 3' - 0" CRAWL SPACE 3' - 0" CRAWL SPACE 6" 12" PRE-MANUFACTURED WOOD TRUSS SYTEM R-49 BATT INSULATION R-21 BATT INSULATION MANUFACTURED STONE FINISH SIDING BEARING PONY WALL(S) FRAMING @ 24" O.C. (TYPICAL)11 7/8" FLOOR JOISTS TOUNGE AND GROOVE DECKING R-14 RIDGID INSULATION COMPACTED BACKFILL CONCRETE FOOTING CONCRETE FOUNDATION WALL SHEATHING 2 X 6 FRAMING AIR FILTRATION BARRIER CLASS C ASPHALT SHINGLES UNDERLAYMENT ROOF SHEATHING 2 X 8 SUB-FACIA STEEL FACIA ALUMINUM SOFFIT R-38 BATT INSULATION STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF 8/24/2022 11:57:19 AM S:\Drawings\923 - Stevens Const Co Spas & Suites\BIM\Spas and Suites(Recovery).rvt A3.1 BU I L D I N G S E C T I O N S 923 HE N R Y ' S F O R K S P A & O F F I C E S U I T E S Issue Date HJF RM RE X B U R G ID A H O 0 SCALE:1/4" = 1'-0" BUILDING SECTION SCALE:1/4" = 1'-0" SECTION Will need stamped engineered truss plans that are also approved by building design professional. All concealed spaces will need fire blocked/draft stopped per section 718. Draft stopping shall subdivide attics into areas no greater then 3000 square feet. (718.4). Need documentation showing anchorage to concrete as per section 1901.3 A2.1 3 A2.1 2 A2.1 4 A2.1 1 A A3.1 B A3.1 0' - 8" 2' - 0" 2' - 0 " 0' - 8 " 90' - 0" 91' - 4" 42 ' - 0 " 43 ' - 4 " 11' - 0"8' - 0"11' - 0"30' - 0"11' - 0"8' - 0"11' - 0" 31' - 4"28' - 8"31' - 4" EQ EQ EQ EQ EQ 1' - 6 " 2x4 PONY WALL WITH ONE SIDE 7/16" OSB 24" X 10" STRUCTURAL FOOTING FOUNDATION WALLS 1' - 6 " 0' - 6 " 18" X 10" STRUCTURAL FOOTING 18" X 10" STRUCTURAL FOOTING 4' - 0 " 2' - 0"6' - 4"2' - 0" 0' - 6" 5' - 1 1 / 4 " 4' - 0 " F1 W1 W2 F1W2 W2 W1 F2 W1 F2 W1 F1 W1 F1 W2 W2 F1 W2F1 W2 W2 F1F1 W2 F1 W3W3 F3F3 W1 F2 F1 F1 F2 F2 F1 F1 F2 F2 W1 W1 FOOTING SCHEDULE MARK F1 F2 F3 1'-6" 2'-0" 2'-6" WIDTH SIZE CONT. CONT. 2'-6" LENGTH 10" 10" 10" THICK (2) #4 CONT. (2) #4 L.W. (2) #4 L.W. BOTTOM REINF. WALL SCHEDULE MARK W1 W2 W3 0'-8" 0'-6" 2'-0" WIDTH SIZE CONT. CONT. 2'-0" LENGTH 10" THICK #4 BAR 24" O.C. #4 BAR 24" O.C. (8) #4 BAR IN CORNERS & CENTER WALL REINFORCEMENT E.W. = EACHWAY L.W. = LENGTHWISE CONT. = CONTINUOUS #4 BAR 16" O.C. #4 BAR 16" O.C. #4 RINGS & 16" O.C. VERTICAL HORIZONTAL STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF 8/24/2022 11:57:20 AM S:\Drawings\923 - Stevens Const Co Spas & Suites\BIM\Spas and Suites(Recovery).rvt S1.1 FO O T I N G A N D F O U N D A T I O N P L A N 923 HE N R Y ' S F O R K S P A & O F F I C E S U I T E S Issue Date HJF RM RE X B U R G ID A H O 0 SCALE:1/4" = 1'-0" FOOTING & FOUNDATION As per city ordinance top horizontal bar in foundation needs to be in the top 6" of wall.