Corrections in the following table need to be applied before a permit can be issued
Review Report
Approved
# 22-00642
Page Reference Annotation
Type
Author : Department Status Page Review Comments Applicant Response Comments
G1.3 Free Text Cody Jones : Building Open 1 Bart S. stated restrooms will meet ADA requirements.
G1.3 Stamp Cody Jones : Building Open 1 Approved - Building Inspector
New Commercial Building
Approval of plans does not constitute approval of variance from code
Powered by TCPDF (www.tcpdf.org)
154 SF
OFFICE
3
2
271 SF
OFFICE
4
2
149 SF
OFFICE
6
1
128 SF
OFFICE
7
1
228 SF
OFFICE
8
2
174 SF
OFFICE
9
2
177 SF
OFFICE
10
2
236 SF
OFFICE
11
2
151 SF
OFFICE
12
2
148 SF
OFFICE
13
1
280 SF
OFFICE
14
2
124 SF
OFFICE
15
1
49 SF
WAITING /
RECTEPTION
16
4
49 SF
WAITING /
RECEPTION
17
4
MAX TRAVRL DISTANCE = 38'-4"
8
77
3 3
2
22
2
2
1
2
1
1
2
1
2
MAX TRAVEL DISTANCE = 45' -3"
MAX TRAVEL DISTANCE = 42' -8"
EXIT
7 OCC.
3' -0" R
3'-0" P
EXIT
7 OCC.
3' -0" R
3'-0" P
EXIT
8 OCC.
3'-0" R
3'-0" P
EXIT
3 OCC.
3' -0" R
3'-0" P
EXIT
3 OCC.
3' -0" R
3'-0" P
MECH.
18
RESTROOM
19 STORAGE
20
RESTROOM
21
CODE REVIEW -2018 IBC
BUILDING CODE GOVERNING:
OCCUPANCY: (CHAPTER 3)
TYPE OF CONSTRUCTION:
(TABLE 601)
BUILDING HEIGHT:
(TABELS 504.3 & 504.4)
ALLOWABLE AREA:
(TABLE 506.2)
AUTOMATIC SPRINKLER SYSTEM
(SECTION 903)
FIRE ALARM DETECTION
SYSTEMS (SECTION 907,
907.2.2)
FIRE RESISTANT
CONSTRUCTION (TABLE 601)
# OF EXITS REQUIRED:
(SECTION 1004, TABLE
1004.5 & SECTION 1006)
CORRIDORS: (SECTION 1020 &
TABLE 1020.1)
CORRIDORS CONTINUED:
(SECTION 1020.2)
IBC 2018 AS ADOPTED BY THE CITY OF REXBURG
V-B NON-SPRINKLERED
OCCUPANT LOAD: BUSINESS
2 EXITS REQUIRED IF DESIGN OCCUPANT
LOAD IS >49 OR TRAVEL DISTANCE TO EXIT >75'
BUSINESS @300 = 28
TOTAL OCCUPANTS = 28
B
BUSINESS
B OCCUPANCY-40' ABOVE GRADE
PLANE & 2 STORY ALLOWED
B OCCUPANCY, 9,000 SF TABULAR
MAX ALLOWABLE, PER STORY
NOT REQUIRED IF OCCUPANT LOAD <500, <100
PERSONS ABOVE OR BELOW LEVEL OF EXIT
DISCHARGE, OR FIRE AREA CONTAINS
AMBULATORY CARE FACILITY
V-B FIRE RESISTANT RATING IS NOT
REQUIRED PER TABLE 601
NONE PROVIDED
CORRIDORS SERVING > 30 CCUPANTS
ARE REQUIRED TO BE FIRE RATED IF
BUILDING IS NON-SPRINKLERED
CORRIDOR WIDTH-44”REQUIRED 44”MINIMUM PROVIDED, TYPICAL IN
PUBLIC CORRIDORS
NO CORRIDORS SERVING >30 OCCUPANTS
OCCUPANT LOAD <500 & IS
SINGLE STORY. DETECTION NOT REQUIRED.
ACTUAL HEIGHT DOES NOT EXCEED THE
40' MAXIMUM ALLOWED BY CODE, 1
STORY
3715 SF TOTAL < 9,000
NOT REQUIRED FOR B OCCUPANCY NOT PROVIDED
ADOPTED CODES
2018 - INTERNATIONAL ENERGY CODE
2018 - INTERNATIONAL BUILDING CODEBUILDING CODE
ENERGY CODE
2017 - IDAHO STATE PLUMBING CODEPLUMBING CODE
2018 - INTERNATIONAL MECHANICAL CODEMECHANICAL CODE
2018 - INTERNATIONAL FIRE CODEFIRE CODE
2017 - NATIONAL ELECTRICAL CODE (N.E.C.)ELECTRICAL CODE
CODE ANALYSIS LEGEND
MINIMUM REQUIRED EXIT WIDTH
REQUIRED EXIT LIGHT
LOCATIONS. SEE IBC 2018
SECTION 1013. (SHOWN ON
ELECTRICAL DRAWINGS)
MAXIMUM OCCUPANT LOAD THRU EXIT
FIRE DEPARTMENT CONNECTION (FDC)
EXIT WIDTH PROVIDED
EXIT
166 OCC.
3'-0"R
4'-0"P
OCCUPANT LOAD AT OPENING
ROOMS WITH AN OCCUPANT LOAD OF 50 OR MORE
IN GROUP A OCCUPANCY SHALL HAVE TWO EXITS
(IBC 2018 SECTION 1006.1)
(LOCATION SHOWN BY LARGE ARROW)
EXIT DISCHARGE TO PUBLIC WAY - IBC 1028
ACCESSIBLE ELEMENT
NON-ACCESSIBLE ELEMENT
ONE-HOUR FIRE RATED RECESSED FIRE EXTINGUISHER
CABINET AND FIRE EXTINGUISHER FIRE EXTINGUISHER -
2A: 10BC
NON-RATED RECESSED MOUNTED FIRE EXTINGUISHER
CABINET AND FIRE EXTINGUISHER FIRE EXTINGUISHER -
2A: 10BC
FE1
FE2
PANIC HARDWARE REQUIRED
BUILDING REQUIRED EXIT
ED
COMMON PATH OF TRAVEL AS PER TABLE 1006.2.1CPT
EXIT ACCESS TRAVEL DISTANCE AS PER TABLE 1017.2
1 HOUR FIRE BARRIER OR PARTITION. SEE WALL
TYPES
ROOM/AREA REQUIRED EXIT
1234
123 SF
12
ROOM NUMBER
ROOM AREA
ROOM OCCUPANCY LOAD
#
11 CUMULATIVE OCCUPANT LOAD AT OPENING
SEE SIGNAGE SCHEDULE AND LAYOUT ON SIGNAGE SHEETS
1. ACCESSIBILITY SIGNAGE: PROVIDE SIGNAGE TO MEET THE REQUIREMENTS OF
ANSI 117.1-2009. PROVIDE SIGNAGE FOR ACCESSIBLE ENTRANCES, RESTROOMS,
ETC.
2. BUILDING ADDRESS: APPROVED NUMBERS OR ADDRESSES SHALL BE
PROVIDED IN SUCH A POSITION AS TO BE CLEARLY VISIBLE AND LEGIBLE FROM
THE STREET OR ROADWAY FRONTING THE PROPERTY IN COMPLIANCE WITH IBC
2018 SECTION 501.2.
3. EXIT SIGNS - SEE SIGNAGE SCHEDULE.
1- SEE CODE REVIEW TABLE FOR COMPLETE WRITTEN CODE ANALYSIS & REVIEW -
ALL AREAS SHOWN HERE ARE REFERENCED WITHIN CODE ANALYSIS.
2- CODE ANALYSIS BASED ON IBC 2018 REQUIREMENTS.
GENERAL NOTES SIGNAGE
STATE OF IDAHO
BRENT A. McFARLAND AR-2561
11
5
2
B
O
N
D
A
V
E
N
U
E
-
S
u
i
t
e
A
RE
X
B
U
R
G
,
I
D
A
H
O
8
3
4
4
0
VO
I
C
E
(
2
0
8
)
3
5
9
-
2
3
0
9
F
A
X
(
2
0
8
)
3
5
9
-
2
2
7
1
WW
W
.
J
R
W
A
.
C
O
M
Job Number:
Date:
Drawn By:
Checked By:
Plot Date:
Consultants:
Drawing Number:
File:
Revisions:
Pr
o
j
e
c
t
:
Dr
a
w
i
n
g
T
i
t
l
e
:
®
J
R
W
&
A
S
S
O
C
I
A
T
E
S
,
P
L
L
C
.
D
R
A
W
I
N
G
S
A
N
D
D
E
S
I
G
N
S
A
R
E
PR
O
T
E
C
T
E
D
B
Y
C
O
P
Y
R
I
G
H
T
A
N
D
T
H
E
A
R
C
H
I
T
E
C
T
R
E
T
A
I
N
S
T
O
TA
L
O
W
N
E
R
S
H
I
P
A
N
D
C
O
N
T
R
OL
.
A
N
Y
U
N
A
U
T
H
O
R
I
Z
E
D
U
S
E
O
F
D
R
A
W
I
N
G
S
,
D
E
S
I
G
N
S
O
R
I
D
EA
S
W
I
T
H
O
U
T
W
R
I
T
T
E
N
C
O
N
S
E
N
T
O
F
T
H
E
A
R
C
H
I
T
E
C
T
I
S
P
R
O
HI
B
I
T
E
D
OF
6/27/2023 3:15:24 PM
S:\Drawings\923 - Stevens Const Co Spas &
Suites\BIM\Spas and Suites.rvt
G 1.3
CO
D
E
P
L
A
N
923
SP
A
S
&
S
U
I
T
E
S
Issue Date
Author
Checker
6-27-2023
RE
X
B
U
R
G
ID
A
H
O
Bart S. stated restrooms will meet ADA requirements.