HomeMy WebLinkAboutSTRUCTURAL LETTER - 22-00568 - Richard Wadholm6949 S High Tech Drive Suite 200 Midvale, UT 84047 P (801) 352-0075 F (801) 352-7989 August 2, 2022 Energy Savers 245 E 2150 N Layton, Utah 84041 Re: Richard Wadholm Residence: 1211 North 2700 West, Rexburg, ID 83440 We have been retained to review the feasibility of adding solar panels to the above referenced site. We have reviewed the solar panel installation site plan and conclude that the panels will not negatively affect the structure at the site mentioned above. The solar panels and their respective design, attachments, and connections shall be per the responsibility of the manufacturer/installer and shall be installed and designed in accordance with the 2018 IBC and ASCE 7-16. The structure is adequate to take on the additional lateral loads due to the solar panels for the following reasons: Any increase in wind loads is negligible due to the mounting pattern of the panels being flush with the existing roof. The solar panels weigh 2.5 psf. Per the IEBC section 503.4, the lateral force resisting system need not be adjusted for less than a 10% change in seismic loads. Since the roof dead load is 15 psf, and the solar panels that weigh 2.5 psf affect less than 50% of the roof structure, the increase in seismic lateral loads is less than 9%. The structure is also adequate to resist the gravity loads due to the solar panels for the following reasons: The existing roof framing consists of 2x8 rafters @ 24” on center. The attached calculations show that the 2x8 rafters are adequate to support the existing dead loads, added solar panel dead loads, and anticipated roof snow loads for the distance that the rafters span between supporting beams. See the attached calculations for further clarification. All attachments of the solar panels to the roof structure shall be staggered and spaced on various rafters/truss top chords per the rail system manufacturer in order to have the loads shared by multiple roof structural elements. Focus Engineering & Surveying is not responsible for any problems produced due to improper installation. Focus Engineering & Surveying also assumes the structure is in good condition and was adequately designed by the original design professional and assumes no liability for problems existing due to improper original design. Sincerely, Lynn Gray Focus Engineering & Surveying Reviewed By: Matthew S. Hakes, P.E. Project Engineer Focus Engineering & Surveying 08/02/2022 Job No: Designer: Checker: Notes:Date: Page:1 Load Roofing Material 1.2 psf Sheathing 15/32 in.1.5 psf Framing @ 24 in.1.3 psf Insulation 0 psf Ceiling Material 2.2 psf User Input 5.7 psf Miscellaneous 3.1 psf 15 psf 50 psf 1 ASCE 7 Ch. 7 1 ASCE 7 Ch. 7 1 ASCE 7 Ch. 1 35.0 psf ASCE 7 Ch. 7 17.8 degrees 0.803 ASCE 7 Figure 7.4-1 28.1 psf ASCE 7 Ch. 7 Dead Load Spreadsheet 22-7901 MH MH ROOF DEAD LOAD Thickness/Spacing Rafter Roof Component Metal Roofing 26 Gage Oriented Strand Board (OSB) 2x8 None ROOF SNOW LOAD Ground Snow Load, Pg 1/2" Gypsum Wallboard Exposure Factor, Ce Total Roof Dead Load Spray Foam Insulation + Solar Panels Slippery Surface Sloped Roof Factor, Cs Thermal Factor, Ct Importance Factor, Is Flat Roof Snow Load, Pf = 0.7CeCtIsPg Roof Slope Sloped Roof Snow Load, Pf = CsPf Page 1 of 1 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)586 @ 2 1/2"3281 (3.50")Passed (18%)--1.0 D + 1.0 S (All Spans) Shear (lbs)499 @ 10 3/8"1501 Passed (33%)1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-lbs)1572 @ 5' 9 1/4"1564 Passed (101%)1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in)0.352 @ 5' 9 1/4"0.586 Passed (L/400)--1.0 D + 1.0 S (All Spans) Total Load Defl. (in)0.511 @ 5' 9 1/4"0.782 Passed (L/276)--1.0 D + 1.0 S (All Spans) System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 4/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Snow Factored Accessories 1 - Beveled Plate - DF 3.50"3.50"1.50"182 404 586 Blocking 2 - Beveled Plate - DF 3.50"3.50"1.50"182 404 586 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)6" o/c Bottom Edge (Lu)12' 2" o/c Dead Snow Vertical Load Location (Side)Spacing (0.90)(1.15)Comments 1 - Uniform (PSF)0 to 11' 6 1/2"24"15.0 35.0 Default Load Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator Weyerhaeuser Notes All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.Member Length : 12' 4 7/16" MEMBER REPORT PASSED Level, 2x8 @ 24" o.c. 1 piece(s) 2 x 8 DF No.2 @ 24" OC ForteWEB Software Operator Job Notes 8/2/2022 6:30:55 PM UTCMatthew S. Hakes, P.E. Focus Engineering & Surveying (801) 352-0075 mhakes@focusutah.com ForteWEB v3.4, Engine: V8.2.2.122, Data: V8.1.2.2 File Name: 22-7901 ES Solar Page 1 / 1 UtahEnergySavers.com ESSolar.net Layton, UT 801-614-0606 WADHOLM RESIDENCE 1211 NORTH 2700 W REXBURG, IDAHO 83440 Sheet 1 of 9 PLANT LOCATION Scale NTS PLANT LOCATION: WADHOLM RESIDENCE 1211 NORTH 2700 W REXBURG, IDAHO 83440 SOLAR EDGE SE7600H-US INVERTER 25 HANWHA Q.PEAK BLK-G4.1 295 PV PANELS SOLAR EDGE SE7600HUB-US INVERTER 31 SOLARIA POWERXT-400R-PM PANELS SOLAR EDGE SE5000H-US INVERTER 17 LG LG335N1C-A5 335 PV PANELS (2) SOLAR EDGE SE7600H-US INVERTER 47 HANWHA Q.PEAK DUO BLK-G5 310 PV PANELS SOLAR EDGE SE7600H-US INVERTER 25 JA JAM60S03-310/PR PV PANELS SOLAR EDGE SE3800H-US INVERTER 14 PANASONIC VBHN320KA03 320 PV PANELS SOLAR EDGE SE7600HUB-US INVERTER 34 VIKRAM SOMERA VSMHBB.60.365 SOLAR EDGE SE7600HUB-US INVERTER 25 S ENERGY SL40-60MBI-360V PANELS REVISION 1: SOLAR EDGE SE7600HUB-US INVERTER 25 VIKRAM SOMERA VSMHBB.60.365 PLAN BY: BRYCE PETERSON 7.6 KW AC PHOTOVOLTAIC SYSTEM UtahEnergySavers.com ESSolar.net Layton, UT 801-614-0606 INSTALL SITE Scale NTSLIMITS OF CONSTRUCTION CONCRETE DRIVEWAY SOLADECK JUNCTION BOX (S) SOLAR EDGE SE7600HUB-US INVERTER (LOCATED NEXT TO SERVICE) EXISTING 200A SERVICE ENTRANCE PANELBOARD Sheet 2 of 9 PHOTOVOLTAIC SYSTEM COMBINER PANEL 100A, 120/240 VAC LOAD CENTER DEDICATED PHOTOVOLTAIC SYSTEM AC DISCONNECT BATTERY (LOCATED INSIDE GARAGE ON SIDEWALL) DEDICATED BATTERY SYSTEM AC DISCONNECT (LOCATED IN SIGHT OF BATTERY) BATTERY UTILITY LOW VOLTAGE DISCONNECT (LOCATED NEXT TO SERVICE) SOLAR BOM NEW SOLADECK JUNCTION BOX (SOLTECTION RJ-1) _1_ QTY NEW JUNCTION BOX (SOLTECTION RU-2LP) _1_ QTY RAIL (SNAPNRACK SERIES 100)= _20_ (14 FT LENGTH) QTY SPLICES (SNAPNRACK SERIES 100)= _16_ QTY MID CLAMP (SNAPNRACK SERIES 100) = 64 QTY END CLAMP (SNAPNRACK SERIES 100) = 8 QTY STANDOFFS FEET AND LAGS (SNAPNRACK SERIES 100) = 68 QTY EACH Portrait = 4 panels per 14’ rail Landscape = 2 panels per 14” rail Portrait = 1 rail to 2 panels (360W/400W = 2 rails to 3 panels) Landscape = 1 rail to 1 panel Splices = 2 for every consecutive 4 panels portrait (3 panels for 360W/400W)/ 2 panels landscape End Clamps = 2 on every end Mid Clamps = 2 on every joint between panel 7.6 KW AC / 12.4 KW DC PHOTOVOLTAIC SYSTEM DEDICATED PHOTOVOLTAIC SYSTEM AC DISCONNECT (LOCATED NEXT TO SERVICE) SOLAREDGE BI-EUSGN-01 BACKUP INTERFACE (LOCATED NEXT TO SERVICE) SOLAREDGE BI-EUSGN-01 BACKUP INTERFACE GENERAL NOTES: ALL CONSTRUCTION / INSTALLATION SHALL COMPLY WITH: 2020 NATIONAL ELECTRICAL CODE (NEC) 2018 INTERNATIONAL FIRE CODE (IFC) 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) ALL DIMENSIONS SHOWN ARE APPROXIMATE UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PV SYSTEM COMPONENTS LOCATED AT SERVICE ENTRANCE ALL CONDUITS ON ROOF SHALL BE A MINIMUM OF ½” OFF ROOF CONSTRUCTION LIMITS: ALL IMPROVEMENTS AND ACCESS SHALL OCCUR WITHIN PLANT PROPERTY LINES EXISTING 200A INTERIOR LOADS PANEL LOCATED IN BASEMENT SOLADECK JUNCTION BOX (S) ONE PER ARRAY G*-SolarEdge Energy Bank 10kWh Battery DS-000026-NAM APPROX. 40' DC RUN (IN ATTIC WHERE AVAILABLE) SOLADECK JUNCTION BOX (S) ONE PER ARRAY WADHOLM RESIDENCE 1211 NORTH 2700 W REXBURG, IDAHO 83440 SOLAR EDGE SE7600HUB-US INVERTER 34 VIKRAM SOMERA VSMHBB.60.365 UtahEnergySavers.com ESSolar.net Layton, UT 801-614-0606 Scale NTS UtahEnergySavers.com ESSolar.net Layton, UT 801-614-0606 Temperature Correction for Largest String (Per NEC Article 690.7): Voc = 41.0 Vdc Temperature Coefficient(Voc) = -0.27%/ CVmax = Voc + [(Tlow** - 25 C) x (-0.27% x Voc)]Vmax = 41.0 Vdc + [(-16 C - 25 C) x (-0.27% x 41.0 Vdc)]Vmax = 45.5 Vdc (<48 Vdc) Maximum Input DC Voltage for SolarEdge S440 = 60.0 V dc **Solarabcs.org extreme low temperature for Ogden Total Array Specs: 34 panels: Power =12410 Watts dc SUBARRAY #1: Maximum System Voltage (Vmax) Inverter Maximum Voltage Rating = 500 Vdc Rated Maximum Power Point Voltage (Vmpp) For 240 Vac grid connection = 350 Vdc Maximum Circuit Current (Imax) Maximum Input Rating of the Inverter = 15 Adc/string For 3 string system = 45 Adc Rated Maximum Circuit Current (Impp) The Lower Value of the following: 1) System power (STC)/Vmp =12410 W / 382.8 Vdc = 32.42 A 2) Inverter Maximum Output Current = 32A at 240 Vac ARRAY WIRING Sheet 3 of 8 12410 DC WATT PHOTOVOLTAIC ARRAY REFER TO THREE LINE WIRING DIAGRAM FOR CONTINUATION WIRE COLORS DC: NEGATIVE - BLACK POSITIVE - RED WIRE COLORS AC: HOT - BLACK and RED NEUTRAL - WHITE GROUND: - GREEN OR BARE 2 #10 THWN-2 CU PV WIRE PER STRING 1 #6 AWG BARE CU GND (EGC) BONDED TO RAIL WITH WEEBL 6.7 LUG AND CLIP ASSEMBLIES. REMAINDER OF ARRAY GROUNDED PER MANUFACTURER'S SPECIFICATIONS. NEC.690.43 SOLAR EDGE POWER OPTIMIZERS TO BE GROUNDED WITH SST STAR WASHER PER MANUFACTURER'S SPECIFICATIONS ONE- LINE ARRAY DIAGRAMEach DC Panel: JAJAM60S03-310/PR Source Circuit: 11 Panels: VIKRAM SOMERA VSMHBB.60.365 With S440 Power Optimizers Power=4015 Watts dc Vmp= 382.8 Vdc Imp= 10.53 Adc 11 Panels: VIKRAM SOMERA VSMHBB.60.365 With S440 Power Optimizers Power=4015 Watts dc Vmp= 382.8 Vdc Imp= 10.53 Adc 12 Panels: VIKRAM SOMERA VSMHBB.60.365 With S440 Power Optimizers Power=4380 Watts dc Vmp= 417.6 Vdc Imp= 10.53 Adc SE3000H-US 12.5 SE3800H-US 16 SE5000H-US 21 SE6000H-US 25 SE7600H-US 32 SE10000H-US 42 SE11400A-US 47.5 Each DC Panel: VIKRAM SOMERA VSMHBB.60.365 7.6 KW AC / 12.4 KW DC PHOTOVOLTAIC SYSTEM WADHOLM RESIDENCE 1211 NORTH 2700 W REXBURG, IDAHO 83440 SOLAR EDGE SE7600HUB-US INVERTER 34 VIKRAM SOMERA VSMHBB.60.365 LOCATED IN GARAGE (UNLESS OTHERWISE SPECIFIED) (2)#8 AWG CU (1)#8 AWG NEUTRAL CU (1)#10 AWG EGC CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR SOLAREDGE BACKUP INTERFACE C* 200A MAIN40A SOLAR BREAKER 200A AUTOMATIC TRANSFER SWITCH EXISTING 200A SERVICE PANEL A* (3)#10 THWN-2-CU BLACK (3)#10 THWN-2-CU RED (1)#10 THWN-2-CU GREEN ¾”EMT CONDUIT AND/OR ¾” SEALTITE FLEXIBLE CONDUIT, TO BE GROUNDED AT EVERY NON METALLIC JUNCTION WITH GROUND BUSHINGS UtahEnergySavers.com
 ESSolar.net
 Layton, UT 801-614-0606
 Scale
 NTS
Sheet 4 of 9
 AC ONE LINE DIAGRAM
 
 E*-30A/2P DISCONNECT (EATON DG221URB)(6)#14 AWG CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR NEW INTERCONNECTED HEAT/SMOKE DETECTOR H* 30A/2P DISCONNECT LOW VOLTAGE EMERGENCY STOP TRIGGER (LOCATED WITHIN 3’ OF SERVICE)B* A*-EXISTING MAIN SERVICE (METER-HEAD ONLY) B*-30A/2P DISCONNECT (EATON DG221URB) C*-SOLAREDGE BACKUP INTERFACE (BI-EUSGN-01) D*-EXISTING SUBPANEL (SQUARE D 200A) E*-60A/2P DISCONNECT (EATON DG222URB) F*-SOLAREDGE 7600W HUB INVERTER (SE7600HUB-US) G*-SOLAREDGE ENERGY BANK 10KWH BATTERY (BAT-10K1P) H*-HEAT/SMOKE DETECTOR (DEPENDANT ON AVAILABILITY) LOCATED IN CEILING ABOVE ESS SHIELDED CAT 5 COMMUNICATIONS GROUNDED ON ONE END 10KWH SOLAREDGE BATTERY G* 7.6KW SOLAR INVERTER F* DC SOLAR CIRCUITS CONTINUE ON PAGE 5 (2)3/0 AWG CU / 4/0 AWG AL (1)3/0 AWG NEUTRAL CU / 4/0 AWG AL (1)#6 AWG EGC CU / #4 AWG AL 2” EMT MIN. W/ THWN-2 /SER CABLE (2)#14 AWG CU (24V EMERGENCY STOP CIRCUIT) ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR DEDICATED PV METER I* EXISTING 200A SUBPANEL (LOCATED IN INTERIOR) *THERE IS ALREADY A 200A MAIN BREAKER IN THE INTERIOR LOADS PANEL PROTECTING THE EXISTING HOUSE FEEDER WIRES IN COMPLIANCE WITH NEC 705.12(B)(1)(B) D* 200A/2P 40A/2P OTHER LOADS (2)#6 AWG CU (1)#6 AWG NEUTRAL CU (1)#6 AWG EGC CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR (2)#8 AWG CU (1)#8 AWG NEUTRAL CU (1)#8 AWG EGC CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR (2)#10 AWG CU (1)#10 AWG NEUTRAL CU (1)#10 AWG EGC CU ¾” EMT MIN. W/ THWN-2 OUTDOOR / NM CABLE INDOOR RMP 1 BATTERY SUB-PANEL MAIN BREAKER 60A/2P VISIBLY OPEN DISCONNECT (LOCATED WITHIN 3’ OF SERVICE) E* (1)#10 THWN-2-CU BLACK (1)#10 THWN-2-CU RED (1)#10 THWN-2-CU GREEN ¾”EMT CONDUIT AND/OR ¾” SEALTITE FLEXIBLE CONDUIT, TO BE GROUNDED AT EVERY NON METALLIC JUNCTION WITH GROUND BUSHINGS I*-SOLAREDGE ENERGY BANK 10KWH BATTERY (BAT-10K1P) J*-SOLAREDGE ENERGY BANK 10KWH BATTERY (BAT-10K1P) G*-SolarEdge Energy Bank 10kWh Battery DS-000026-NAM B*-NEW 125A SUBPANEL (EATON BR816L125RP) 10KWH SOLAREDGE BATTERY G* *DUE TO SUPPLY LIMITATIONS WE WILL BE INSTALLING A 7.6KW HUB INVERTER AND SET THE POWER CONTROL SYSTEM / ENERGY MANAGEMENT SYSTEM TO ONLY ALLOW BACKFEED OF UP TO 5KVA (20A) (NEC 705.13 AND NEC 750) (2)3/0 AWG CU / 4/0 AWG AL (1)3/0 AWG NEUTRAL CU / 4/0 AWG AL (1)#6 AWG EGC CU / #4 AWG AL 2” EMT MIN. W/ THWN-2 /SER CABLE (2)1/0 AWG CU / 2/0 AWG AL (1)1/0 AWG NEUTRAL CU / 2/0 AWG AL (1)#6 AWG EGC CU / # 4 AWG AL 1 ½ ” EMT MIN. W/ THWN-2 OUTDOOR / SER CABLE INDOOR (2)#1 AWG CU / 1/0 AWG AL (1)#1 AWG NEUTRAL CU / 1/0 AWG AL (1)#6 AWG EGC CU / #4 AWG AL 1 ½ ” EMT MIN. W/ THWN-2 OUTDOOR / SER CABLE INDOOR (2)#2 AWG CU / #2 AWG AL (1)#2 AWG NEUTRAL CU / #2 AWG AL (1)#8 AWG EGC CU / #6 AWG AL 1 ½ ” EMT MIN. W/ THWN-2 OUTDOOR / SER CABLE INDOOR 7.6 KW AC / 12.4 KW DC PHOTOVOLTAIC SYSTEM WADHOLM RESIDENCE 1211 NORTH 2700 W REXBURG, IDAHO 83440 SOLAR EDGE SE7600HUB-US INVERTER 34 VIKRAM SOMERA VSMHBB.60.365 NEW JUNCTION BOX (SOLTECTION RU-2LP) G POS NEG G POS NEG UtahEnergySavers.com
 ESSolar.net
 Layton, UT 801-614-0606
 Scale
 NTS
 13 *5
 *5
 *5
 *5
 *5
 *5
 *5
 *5
 *4
*3
 *1
 EXISTING 200A
 MAIN SERVICE PANEL
 TRANSITION BOX 
SOLADECK JUNCTION BOXES
 IN ATTIC
 (EXTERIOR *7,*12)
 (NEXT TO SOLAR BREAKER
 *2,*6)
 AC INPUT 2
 UTILITY AC INPUT 1
 AC I N P U T 3 
 AC OUTPUT
 DC INPUT
 CRITICAL LOADS
 B
 THIS IS NOT A PARALLEL GENERATION SYSTEM
 MAIN SERVICE PANEL
4 #10 THWN-2 CU PV WIRE1 #10 THWN-2 CU GND3/4" EMT CONDUITSOLADECK JUNCTION BOX TRANSITION BOX 1 DC 11 DC DC DC DC DC 1 DC DC DC 11 12410 DC WATT PHOTOVOLTAIC ARRAY 1 2 #10 AGW 600V PV / USE-2 PER STRING- BLACK and RED 1 #6 AWG BARE CU GND (EGC) BONDED TO RAIL WITH WEEBL 6.7 LUG AND CLIP ASSEMBLIES. REMAINDER OF ARRAY GROUNDED PER MANUFACTURER'S SPECIFICATIONS. NEC.690.43 SOLAR EDGE S440 POWER OPTIMIZERS TO BE GROUNDED WITH SST STAR WASHER PER MANUFACTURER'S SPECIFICATIONS DC THREE LINE DIAGRAM
 
 G POS NEG G POS NEG G POS NEG G POS NEG POS NEG G POS NEG POS NEG NEW SOLADECK JUNCTION BOX (SOLTECTION RJ-1) 3- #10 THWN-2-CU BLACK 3- #10 THWN-2-CU RED 1- #10 THWN-2-CU GREEN ¾”EMT CONDUIT AND/OR ¾” SEALTITE FLEXIBLE CONDUIT, TO BE GROUNDED AT EVERY NON METALLIC JUNCTION WITH GROUND BUSHINGS 1 DC 12 DC DC DC G POS NEG G POS NEG G POS NEG Sheet 5 of 9 1/2" MC CABLE 2 #10 MC CABLE 1 #10 CU GND IN ATTIC SECURED ACCORDING TO NEC 690.31 (D)(1) AND TO BE GROUNDED AT EVERY NON METALLIC JUNCTION WITH GROUND BUSHINGS CONTINUATION ON PAGE 4 TO INVERTER *SOLAR EDGE S440 OPTIMIZERS FOR EACH PANEL 7.6 KW AC / 12.4 KW DC PHOTOVOLTAIC SYSTEM WADHOLM RESIDENCE 1211 NORTH 2700 W REXBURG, IDAHO 83440 SOLAR EDGE SE7600HUB-US INVERTER 34 VIKRAM SOMERA VSMHBB.60.365 ARRAY SELF WEIGHT 34 S ENERGY 365W PANELS 18.7 kg = 41.2 LBS/PANEL + snap-n-rack RACKING MOUNTING HARDWARE:34 X 41.888 = 1425 A = L x W (PANEL): 39.44” X 65.55 = 17.95 SQ FT X 34 = 611 TOTAL SQ FT OF PLANE VIEW ROOF AREA = 5550 PERCENTAGE OF ROOF AREA COVERED IN SOLAR PANELS = 11.01% (IFC 1204.2.1.2) ARRAY: 1425 LBS / 611 SQ FT = 2.3 PSF MAX WEIGHT PER ANCHOR = 44.6 LBS (FOR 4’0” SPANS) PULL OUT STRENGTH CONNECTOR 5/16 LAG BOLT 68 STANDOFFS (68 LAGS) 68 x 3” EMBED x 210 LBS = 42840 LBS WEATHER LOADING GROUND SNOW: 50PSF WIND SPEED: 160MPH EXPOSURE CATEGORY: B LIMITS OF CONSTRUCTION UtahEnergySavers.com ESSolar.net Layton, UT 801-614-0606 MOUNTING AND WEIGHT LOAD Scale NTS MEETS OR EXCEEDS 2018 IBC IRC CONSTRUCTION STANDARDS CASE 1 Load Calculations 2X4 construction, 24" on center trusses ROOF LOAD BEARING ______ LBS / ___ STANDOFFS = _____LBS TOTAL WEIGHT = PANELS + HARDWARE 1412.5 LBS 1412.5 LBS / 460.75 SQ FT= 3.065 PSF DEDICATED PHOTOVOLTAIC SYSTEM AC DISCONNECT Sheet 6 of 9 TIMES PANELS BY 630 ALL ROOF PENETRATIONS MUST BE PROPERLY FLASHED. IRC M2302.2.2. THIS INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS SPECIFIED IN SECTION 1204 OF THE 2018 INTERNATIONAL FIRE CODE. ROOF RACKING SUPPORT SPACING NOT TO EXCEED 4’ SPACING. ALL SUPPORTS MUST BE STAGGERED FROM ONE ROW OF RACKING TO THE NEXT SO NOT ALL SUPPORTS ARE BEARING ON THE SAME TRUSSES SOLAR PV MODULES CANNOT BE INSTALLED OVER OR BLOCK ANY ATTIC VENTS, PLUMBING VENTS, FURNACES OR WATER HEATER VENTS, ETC ALL WIRING MUST BE SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE AND WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE. 36 INCH FIRE DEPARTMENT SETBACK 36” PATHWAYS TO RIDGE WE WILL BE OBSERVING IFC 1204.2 EXCEPTION 1TO BE USED WHEN USING A BARN OR NON INHABITED SPACE FOR ROOF TOP INSTALL THIS INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS SPECIFIED IN THE UTAH AMENDED SECTIONS OF THE 2018 IRC THAT PERTAIN TO ENERGY STORAGE SYSTEMS INCLUDING SHEET ROCK AND AN INTERCONNECTED FIRE ALARM IN THE ROOM OF THE ENERGY STORAGE SYSTEM FOR GRANTSVILLE: WEATHER LOADING GROUND SNOW: 30PSF WIND SPEED: 115MPH EXPOSURE CATEGORY: C FOR BINGHAM COUNTY IDAHO: WEATHER LOADING GROUND SNOW: 42PSF WIND SPEED: 115MPH EXPOSURE CATEGORY: C 7.6 KW AC / 12.4 KW DC PHOTOVOLTAIC SYSTEM WADHOLM RESIDENCE 1211 NORTH 2700 W REXBURG, IDAHO 83440 SOLAR EDGE SE7600HUB-US INVERTER 34 VIKRAM SOMERA VSMHBB.60.365 UtahEnergySavers.com ESSolar.net Layton, UT 801-614-0606 SIGNAGE Scale NTS 1 DUAL INPUT SOURCE SECOND SOURCE IS SOLAR PV SYSTEM ALL SIGNAGE MUST BE PERMANENTLY ATTACHED AND NOT HAND-WRITTEN. NEC 110.21(B) SIGN LOCATED AT POINT OF INTERCONNECTION. NEC 690.56(B) AND 705.10 AND 712.10 2 WARNING:SOLAR POWER SOURCE OUTPUT CONNECTION, DO NOT RELOCATE THIS OVERCURRENT DEVICE SIGN LOCATED NEXT TO SOLAR BACKFEED BREAKERS AT SERVICE PANEL. IF BREAKER FEED AND UTILIZING THE 120% RULE NEC 705.12(B)(2)(3)(b) 3 RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM SIGN LOCATED NEXT TO THE SOLAR AC OR DC DISCONNECT THAT ACTIVATES RAPID SHUTDOWN. NEC 690.56 (C) (3) OR NEXT TO MAIN SERVICE DISCONNECT OR NEXT TO A RSD RELAY SIGNAL BUTTON 5 PHOTOVOLTAIC POWER SOURCE THIS SIGN IS LOCATED ON THE OUTSIDE OF ANY CONDUITS, ENCLOSURES, OR MC CABLE THAT CONTAINS DC CIRCUITS. The markings shall be reflective and be provided at every enclosure, every 10’ along conduit or MC cable, and at each side of where the conduit or cable passes through a wall, floor, or any other partition. NEC 690.31(G)(3-4) and IFC 605.11.1.2 8 4 PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH MAX SYSTEM VOLTAGE= 480 VDC MAX CIRCUIT CURRENT= 15 ADC MAX CURRENT FOR POWER OPTIMISERS= 15 ADC THIS SIGN IS LOCATED ON THE OUTSIDE OF EACH DC DISCONNECT. NEC 690.53 and 690.13(B) 7 PV SYSTEM BACKFEEDING THROUGH THIS PANEL AC OUTPUT CURRENT= 32 AAC AC VOLTAGE=240 VAC THIS SIGN IS LOCATED AT THE BACKFEED PANEL BOARD NEC 690.54 Sheet 7 of 9 11PHOTOVOLTAIC SYSTEM DEDICATED KWH METER THIS SIGN IS LOCATED AT THE DEDICATED KWH METER 6 NOTICE: PV SYSTEM COMBINER PANEL DO NOT ADD LOADS TO THIS PANEL THIS SIGN IS LOCATED AT THE COMBINER PANEL PHOTOVOLTAIC SYSTEM AC DISCONNECT THIS SIGN IS LOCATED AT THE AC PV SYSTEM DISCONNECT 690.13 (B) THIS SIGN IS LOCATED ON OR WITHIN 3’ FEET OF THE SERVICE METER PANELBOARD AND ON ANY AC DISCONNECT SWITCH ON THE OUTSIDE OF THE BUILDINGS NEC 690.56(C)(1) / IFC 1204.5.1 9 SE3000H-US 12.5 SE3800H-US 16 SE5000H-US 21 SE6000H-US 25 SE7600H-US 32 SE10000H-US 42 SE11400A-US 47.5 9 CAUTION: MULTIPLE SOURCES OF POWER POWER TO THIS SERVICE IS ALSO SUPPLIED FROM A PV SYSTEM CONNECTED TO THE AC SERVICE PANEL. LITHIUM BATTERY IS LOCATED IN GARAGE. SIGN LOCATED AT ALL POINTS OF INTERCONNECTION. NEC 690.56(B) AND 705.10 AND 706.11(A) AND 712.10 Ansi z535.4 color specific ENERGY STORAGE SYSTEM DISCONNECT NOMINAL AC VOLTAGE=__N/A__VAC MAX DC VOLTAGE=__520__VDC AVAILABLE FAULT CURRENT=_18.9_ADC DATE CALCULATIONS PERFORMED SIGN LOCATED AT ENERGY STORAGE SYSTEM DISCONNECTS NEC 706.15(C) 10 7.6 KW AC / 12.4 KW DC PHOTOVOLTAIC SYSTEM WADHOLM RESIDENCE 1211 NORTH 2700 W REXBURG, IDAHO 83440 SOLAR EDGE SE7600HUB-US INVERTER 34 VIKRAM SOMERA VSMHBB.60.365 UtahEnergySavers.com ESSolar.net Layton, UT 801-614-0606 PLACARDS Scale NTS ALL SIGNAGE MUST BE PERMANENTLY ATTACHED AND NOT HAND-WRITTEN. NEC 110.21(B) Sheet 8 of 9 11 PARALLEL GENERATION ON SITE THIS PLACARD IS LOCATED NEXT TO METER SOCKET. 2”X4” ENGRAVED METAL OR RED AND WHITE HARD PLASTIC ⅜” OR LARGER LETTERS MANUAL DISCONNECT FOR PARALLEL GENERATION AND BATTERY THIS PLACARD IS LOCATED AT THE ESS SYSTEM DISCONNECT. 2”X4” ENGRAVED METAL OR RED AND WHITE HARD PLASTIC ⅜” OR LARGER LETTERS 12 N WARNING: MULTIPLE SOURCES OF POWER. A PV SYSTEM IS PRESENT. DISCONNECT ALL POWER SOURCES BEFORE SERVICING. FOR ST GEORGE POWER 7.6 KW AC / 12.4 KW DC PHOTOVOLTAIC SYSTEM WADHOLM RESIDENCE 1211 NORTH 2700 W REXBURG, IDAHO 83440 SOLAR EDGE SE7600HUB-US INVERTER 34 VIKRAM SOMERA VSMHBB.60.365 Scale NTS SIGNAGE LOCATION Sheet 9 of 9 13 *5 *5 *5 *5 *5 *5 *5 *4 *1 EXISTING 200A MAIN SERVICE PANEL SOLAREDGE SE7600HUB-US INVERTER TRANSITION BOX SOLADECK JUNCTION BOXES IN ATTIC (EXTERIOR *7) (NEXT TO SOLAR BREAKER *2,*6) *3 200A SOLAREDGE BACKUP INTERFACE *1, *2, *6, *8, *9 *11, *12 * NOT REFLECTIVE OF ACTUAL EQUIPMENT LOCATION DEDICATED PV METER IN GARAGE 10KWH SOLAREDGE BATTERY *10
 *3, *10, *12 LOCKABLE VISIBLY OPEN DISCONNECT * FOR SIGNAGE AND PLACARDS SEE PAGES 7 AND 8 *ONLY APPLICABLE STICKER WILL BE SHOWN ON PAGES 7 AND 8 AND INSTALLED ON SITE. VISIBLY OPEN DISCONNECT *1,*8,*3 TO EXISTING INTERIOR LOADS PANEL 10KWH SOLAREDGE BATTERY UtahEnergySavers.com ESSolar.net Layton, UT 801-614-0606 7.6 KW AC / 12.4 KW DC PHOTOVOLTAIC SYSTEM WADHOLM RESIDENCE 1211 NORTH 2700 W REXBURG, IDAHO 83440 SOLAR EDGE SE7600HUB-US INVERTER 34 VIKRAM SOMERA VSMHBB.60.365