Loading...
HomeMy WebLinkAboutNWFCS Rexburg FATOILET 108 OFFICE 111 OFFICE 110 TOILET 109 FEC HALL 112 MECH 2 JAN/ 107 VEST. 113 114 OFFICE 115 HALL 116 HALL 117 WORK 106 LARGE CONF. 103 COFFEE HALL 122 ELECT PANEL OFFICE 118 OFFICE 119 SERVER RACK DATA/ELEC. 120 CONF. SMALL 121 OFFICE 101 RECEPT 102 104 MKTG STOR MECH 1/ 105 ELECT PANEL +54" USB VEST. 100 N FIRE ALARM STILLNESSBRASSFAUCETK-942-4 FE C FA C P H L1•D012 135° H L1•D011 135° H L1•D015 135° H L1•D014 135° S L1•D001 S L1•D003 S L1•D004 S L1•D005 S L1•D007 S L1•D008 S L1•D009 S L1•D010 S L1•D013 S L1•D016 S L1•D022 S L1•D020 S L1•D017 S L1•D018 S L1•D019 F L1•M006 F L1•M021 FAA ANN AOM L1•M002 RM N1•01 115cd WP N1•04 15cd C N2•02 15cd C N2•01 15cd C N2•03 15cd C N2•05 EOL 4.7k 15cd CN1•02 30cd C N1•05 EOL 4.7k 30cd C N2•04 30cd C 1 D 1 D 1 V SCALE: 1/4" = 1'-0" 1 D CABLE AND WIRE LEGEND LABEL PART NO AW G RESISTANCE (Ω/KFT)DESCRIPTION TOTAL LENGTH D 18/4 UNS FPLP RED 18 7.77 4 COND. SOLID COPPER FPLP UNS 304' SBUS 18/4 FPLP/R (SBUS)18 7.77 4 COND. SOLID COPPER FPLP/R ANALOG UNSHIELDED 24' V 14/2 FPLP/R (NAC)14 3.07 2 COND. SOLID COPPER FPLP/R ANALOG UNSHIELDED 229' CE L L APPROX. 3,400 SQUARE FEET OCCUPANCY TYPE: B, NON-SPRINKLERED SCOPE OF WORK: TO INSTALL AND TEST NEW, FULL COVERAGE FIRE ALARM SYSTEM. DE S C R I P T I O N Nu m b e r AP P R . De s i g n e d b y : Dr a w n b y : Ap p r o v e d B y : Pr o j e c t N u m b e r : Da t e : DA T E : RE V I S I O N 1 A 2345 B C D Sc a l e : Dr a w i n g C o d e : SHEET REFERENCE NUMBER: IN T E G R I T Y F I R E & SE C U R I T Y 80 0 7 E . 1 2 9 N . Id a h o F a l l s I D . 8 3 4 0 1 20 8 - 5 1 6 - 8 6 4 3 Ch r i s @ I n t e g r i t y F i r e . c o m 7/ 9 / 2 0 2 2 1. 0 FA - 1 . 0 NI C E T I V # 1 6 5 3 5 1 Ch r i s S c h m i d t Cr e d i t S e r v i c e s No r t h w e s t F a r m 1/ 4 " = 1 ' FA-1.0 7/ 9 / 2 0 2 2 10 3 6 E r i k s o n D r . Re x b u r g , I D . 8 3 4 4 0 C:\Users\candr\OneDrive\Documents\FireCAD Projects\NWFCS Rexburg.dwg, 8/30/2022 2:08:13 PM N1 POINT-TO-POINT REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:0.24 Min. Operational Voltage:16 End Of Line Voltage:20.16 Max. Circuit Current (A):2.5 Voltage Drop Percent:1.17 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.54 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):139 Spare Current (A):1.96 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):0.85509 Spare Current (A) Percent:78.40 % Device Label Part No.Description Device Current (A)Remaining Current (A)Dist. From Previous (Ft)Resistance From Previous (Ω) Voltage Drop From Previous Voltage At Device Total Voltage Drop Voltage Drop Percent N1•01 P2WK 2-Wire Horn Strobe, Standard cd, Outdoor 115cd 0.218 0.54 14 0.088172 0.05 20.35 0.05 0.23 % N1•02 PC2WL 2-Wire, Horn Strobe, White 30cd 0.09 0.322 46 0.282879 0.09 20.26 0.14 0.68 % N1•03 SCW Strobe, White 15cd 0.071 0.232 60 0.366524 0.09 20.18 0.22 1.10 % N1•04 SCW Strobe, White 15cd 0.071 0.161 8 0.049145 0.01 20.17 0.23 1.14 % N1•05 EOL 4.7k PC2WL 2-Wire, Horn Strobe, White 30cd 0.09 0.09 11 0.06837 0.01 20.16 0.24 1.17 % Calculation Methods: Resistance From Previous (Ω) = Wire Resistance (Ω/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (Ω) x Remaining Current (A) N2 POINT-TO-POINT REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:0.11 Min. Operational Voltage:16 End Of Line Voltage:20.29 Max. Circuit Current (A):2.5 Voltage Drop Percent:0.55 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.374 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):90 Spare Current (A):2.126 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):0.549669 Spare Current (A) Percent:85.04 % Device Label Part No.Description Device Current (A)Remaining Current (A)Dist. From Previous (Ft)Resistance From Previous (Ω) Voltage Drop From Previous Voltage At Device Total Voltage Drop Voltage Drop Percent N2•01 SCW Strobe, White 15cd 0.071 0.374 5 0.030612 0.01 20.39 0.01 0.06 % N2•02 SCW Strobe, White 15cd 0.071 0.303 19 0.118036 0.04 20.35 0.05 0.23 % N2•03 SCW Strobe, White 15cd 0.071 0.232 26 0.16038 0.04 20.32 0.08 0.41 % N2•04 PC2WL 2-Wire, Horn Strobe, White 30cd 0.09 0.161 18 0.111322 0.02 20.3 0.1 0.50 % N2•05 EOL 4.7k SCW Strobe, White 15cd 0.071 0.071 21 0.129319 0.01 20.29 0.11 0.55 % Calculation Methods: Resistance From Previous (Ω) = Wire Resistance (Ω/Ft) x 2 x Dist. From Previous (Ft) Voltage Drop From Previous = Resistance From Previous (Ω) x Remaining Current (A) DEDICATED 120V 20 AMP CIRCUIT H N G FIRE ALARM CONTROL UNIT S L1•D001 AOM L1•M002 RM S L1•D003 S L1•D004 S L1•D005 F L1•M006 S L1•D007 S L1•D008 S L1•D009 S L1•D010 H L1•D011 135° H L1•D012 135° S L1•D013 H L1•D014 135° H L1•D015 135° S L1•D016 S L1•D017 S L1•D018 S L1•D019 S L1•D020 F L1•M021 S L1•D022 N2•01 15cd C N2•02 15cd C N2•03 15cd C N2•04 30cd C N2•05 EOL 4.7k 15cd C N1•01 115cd WP N1•02 30cd C N1•03 15cd C N1•04 15cd C N1•05 EOL 4.7k 30cd C ANNUNCIATOR ANN-BUS PRI•1 CELLULAR COMM DE S C R I P T I O N Nu m b e r AP P R . De s i g n e d b y : Dr a w n b y : Ap p r o v e d B y : Pr o j e c t N u m b e r : Da t e : DA T E : RE V I S I O N 1 A 2345 B C D Sc a l e : Dr a w i n g C o d e : SHEET REFERENCE NUMBER: IN T E G R I T Y F I R E & SE C U R I T Y 80 0 7 E . 1 2 9 N . Id a h o F a l l s I D . 8 3 4 0 1 20 8 - 5 1 6 - 8 6 4 3 Ch r i s @ I n t e g r i t y F i r e . c o m 7/ 9 / 2 0 2 2 1. 0 FA 1 . 1 NI C E T I V # 1 6 5 3 5 1 Ch r i s S c h m i d t Cr e d i t S e r v i c e s No r t h w e s t F a r m 1/ 4 " = 1 ' FA-1.1 7/ 9 / 2 0 2 2 10 3 6 E r i k s o n D r Re x b u r g , I D . 8 3 4 4 0 C:\Users\candr\OneDrive\Documents\FireCAD Projects\NWFCS Rexburg.dwg, 8/30/2022 2:08:16 PM N1 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:0.46 Min. Operational Voltage:16 End Of Line Voltage:19.94 Max. Circuit Current (A):2.5 Voltage Drop Percent:2.26 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.54 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):139 Spare Current (A):1.96 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):0.85509 Spare Current (A) Percent:78.40 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SCW Strobe, White 15cd 2 0.071 0.142 PC2WL 2-Wire, Horn Strobe, White 30cd 2 0.09 0.18 P2WK 2-Wire Horn Strobe, Standard cd, Outdoor 115cd 1 0.218 0.218 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) C C WP N2 LUMP SUM REPORT CIRCUIT SETTINGS TOTALS Starting Calculation Voltage:20.4 Max. Voltage Drop:0.21 Min. Operational Voltage:16 End Of Line Voltage:20.19 Max. Circuit Current (A):2.5 Voltage Drop Percent:1.01 % Wire Resistance (Ω/kFt):3.07 Total Circuit Current (A):0.374 Circuit Wiring Properties: 'V' 14/2 FPLP/R (NAC) 14 AWG, 2 Cond. Solid Copper FPLP/R Analog Unshielded Total Circuit Length (Ft):90 Spare Current (A):2.126 Distance measured using drawn segment lengths with 10.00 % additional length calculated Total Circuit Resistance (Ω):0.549669 Spare Current (A) Percent:85.04 % DEVICE TOTALS Symbol Part No.Description Qty.Device Current (A)Total Current (A) SCW Strobe, White 15cd 4 0.071 0.284 PC2WL 2-Wire, Horn Strobe, White 30cd 1 0.09 0.09 Calculation Methods: Total Resistance (Ω) = Wire Resistance (Ω/Ft) x 2 x Total Circuit Length (Ft) Total Voltage Drop = Total Resistance (Ω) x Total Circuit Current (A) C C PANEL LOAD SUMMARY STANDBY CURRENT (AMPS)ALARM CURRENT (AMPS) SUMMARY REPORT PANEL POWER SUPPLY MAX CURRENT = 2.7A TOTAL USED CAPACITY = 1.53A (56.67 %) PANEL COMPONENT SUMMARY QTY PART NO DESCRIPTION CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL 1 ES-50X Main Board Main Board for ES-50X Fire Alarm Control Panel 1 x 0.141 = 0.141 1 x 0.257 = 0.257 1 IPOTS-COM Dual technology (POTS and IP) communicator(replacement board) for the Endurance Series panels 1 x 0.04 = 0.04 1 x 0.257 = 0.257 CIRCUIT SUMMARY CIRCUIT ANN-BUS PRI 1 x 0 = 0 1 x 0 = 0 L1 1 x 0.004805 = 0.004805 1 x 0.102 = 0.102 N1 1 x 0 = 0 1 x 0.54 = 0.54 N2 1 x 0 = 0 1 x 0.374 = 0.374 TOTAL STANDBY CURRENT 0.185805 TOTAL ALARM CURRENT 1.53 CIRCUIT DETAILS AND CALCULATIONS STANDBY CURRENT ALARM CURRENT POINT-TO-POINT VOLTAGE DROP CALCULATION SUMMARY SPEAKER POWER/DB LOSS CALCULATIONS SOURCE MAX CAPACITY TOTAL USED CAPACITY AVAILABLE CAPACITY CIRCUIT AWG SYMBOL QTY PART NO DEVICE SETTING CIRCUIT LENGTH CIRCUIT RESISTANCE (Ω/ft) CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL (A) STARTING CALCULATION VOLTAGE END OF LINE VOLTAGE VOLTAGE DROP TOTAL USED WATTS STARTING CALCULATION VOLTAGE END OF LINE VOLTAGE POWER LOSS PERCENT TOTAL DB LOSS ES-50X Main Board L1 18 2 BG-12LX 304'0.00777 2 x 0.000375 = 0.00075 2 x 0.005 = 0.01 1 CRF-300 1 x 0.000255 = 0.000255 1 x 0.0065 = 0.0065 4 H365 w/B300-6 4 x 0.0002 = 0.0008 4 x 0.0045 = 0.018 15 SD365 w/B300-6 15 x 0.0002 = 0.003 15 x 0.0045 = 0.0675 N1 14 1 P2WK 115cd 139'0.00307 1 x 0 = 0 1 x 0.218 = 0.218 20.4v 20.16v 0.24v2PC2WL30cd2 x 0 = 0 2 x 0.09 = 0.18 2 SCW 15cd 2 x 0 = 0 2 x 0.071 = 0.142 N2 14 1 PC2WL 30cd 90'0.00307 1 x 0 = 0 1 x 0.09 = 0.09 20.4v 20.29v 0.11v 4 SCW 15cd 4 x 0 = 0 4 x 0.071 = 0.284 SECONDARY POWER SOURCE REQUIREMENTS REQUIRED STANDBY TIME = 24 HOURS PROVIDE (2) 12V 7AH BATTERIES @ 24VDC REQUIRED ALARM TIME = 5 MINUTES SECONDARY STANDBY LOAD 0.185805 x 24 = 4.46 AH SECONDARY ALARM LOAD 1.53 x 0.08 = 0.13 AH STANDBY AND ALARM LOAD SUBTOTAL 4.59 AH DERATING FACTOR x 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS)5.5 AH F AOM RM H 135° S WP C C BATTERY CALCULATION (SECONDARY POWER SOURCE REQUIREMENTS) PANEL POWER SUPPLY MAX CURRENT = 2.7A TOTAL USED CAPACITY (IN ALARM) = 1.53A (56.67 %) STANDBY CURRENT (AMPS)SECONDARY ALARM CURRENT (AMPS) PANEL COMPONENTS QTY PART NO.DESCRIPTION CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL 1 ES-50X Main Board Main Board for ES-50X Fire Alarm Control Panel 0.141 0.141 0.257 0.257 1 IPOTS-COM Dual technology (POTS and IP) communicator(replacement board) for the Endurance Series panels 0.04 0.04 0.257 0.257 CIRCUIT SYMBOL QTY PART NO DESCRIPTION CURRENT DRAW (A)TOTAL (A)CURRENT DRAW (A)TOTAL (A) ANN-BUS PRI 1 ANN-80 Red 80 character LCD Annunciator 0 0 0 0 L1 2 BG-12LX Addressable manual pull station with interface module mounted inside 0.000375 0.00075 0.005 0.01 1 CRF-300 Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. 0.000255 0.000255 0.0065 0.0065 4 H365 w/B300-6 White, Low-profile 135°F fixed thermal sensor, Standard Base 0.0002 0.0008 0.0045 0.018 15 SD365 w/B300-6 White, Addressable photoelectric detector, Standard Base 0.0002 0.003 0.0045 0.0675 N1 1 P2WK 2-Wire Horn Strobe, Standard cd, Outdoor 115cd 0 0 0.218 0.218 2 PC2WL 2-Wire, Horn Strobe, White 30cd 0 0 0.09 0.18 2 SCW Strobe, White 15cd 0 0 0.071 0.142 N2 1 PC2WL 2-Wire, Horn Strobe, White 30cd 0 0 0.09 0.09 4 SCW Strobe, White 15cd 0 0 0.071 0.284 TOTAL STANDBY (A)0.185805 TOTAL ALARM (A)1.53 REQUIRED STANDBY TIME = 24 HOURS REQUIRED ALARM TIME = 5 MINUTES SECONDARY STANDBY LOAD (A)0.185805 24 4.46 SECONDARY ALARM LOAD (A)1.53 0.08 0.13 STANDBY AND ALARM SUBTOTAL (AMP HOURS)4.59 DERATING FACTOR 1.2 SECONDARY LOAD REQUIREMENTS (AMP HOURS)5.5 PROVIDE (2) 12V 7AH BATTERIES @ 24VDC FAA F AOM RM H 135° S WP C C C C DE S C R I P T I O N Nu m b e r AP P R . De s i g n e d b y : Dr a w n b y : Ap p r o v e d B y : Pr o j e c t N u m b e r : Da t e : DA T E : RE V I S I O N 1 A 2345 B C D Sc a l e : Dr a w i n g C o d e : SHEET REFERENCE NUMBER: IN T E G R I T Y F I R E & SE C U R I T Y 80 0 7 E . 1 2 9 N . Id a h o F a l l s I D . 8 3 4 0 1 20 8 - 5 1 6 - 8 6 4 3 Ch r i s @ I n t e g r i t y F i r e . c o m 7/ 9 / 2 0 2 2 1. 0 FA - 1 . 2 NI C E T I V # 1 6 5 3 5 1 Ch r i s S c h m i d t Cr e d i t S e r v i c e s No r t h w e s t F a r m 1/ 4 " = 1 ' FA-1.2 7/ 9 / 2 0 2 2 10 3 6 E r i k s o n D r Re x b u r g , I D . 8 3 4 4 0 C:\Users\candr\OneDrive\Documents\FireCAD Projects\NWFCS Rexburg.dwg, 8/30/2022 2:08:21 PM