HomeMy WebLinkAboutCIVIL (6-23-22) - 22-00449 - Friendship EstatesFi l e L o c a t i o n : z: \ p r o j e c t s \ 2 0 2 2 \ 2 2 0 4 6 b r a n t l e y b r o o k s s u b d i v i s i o n \ 3 . 0 d e s i g n \ 3 . 1 c a d \ 3 . 1 3 f i n a l \ 2 2 0 4 6 s p c o v e r . d w g Pl o t t e d B y : ru s s e l l Da t e P l o t t e d : Th u r s d a y , J u n e 2 3 2 0 2 2 a t 0 9 : 0 3 A M 1 G- 1 CO V E R IDAHO FALLS REXBURG BLACKFOOT CHUBBUCK TWIN FALLS SUN VALLEY CASCADE McCALL BOISE MOSCOW COUER d' ALENE RUPERT SALMON AMMON ST.ANTHONY ISLAND PARK POCATELLO MOUNTAIN HOME RIGBY IONA SHELLEY CIVIL SITEWORK FOR: PART OF THE EAST 1/2 OF THE SOUTHWEST 1/4 OF SECTION 20, TOWNSHIP 6 NORTH, RANGE 40 EAST, BOISE MERIDIAN, CITY OF REXBURG, MADISON COUNTY, IDAHO APPROVED BY: CITY OF REXBURG ENGINEERING DEPARTMENT APPROVED BY: ROCKY MOUNTAIN POWER APPROVED BY: CITY OF REXBURG FIRE DEPARTMENT APPROVED BY: CENTURY LINK APPROVED BY: INTERMOUNTAIN GAS FRIENDSHIP ESTATES N 4 T H E MA D I S O N A V E N 3 R D E E 1ST N E 2ND N REE D S T AG L E R O C K N G I N E E R I N G SU R V E Y E D B Y : DR A W N B Y : PR O J E C T N O . AP P R O V E D B Y : DE S C R I P T I O N DA T E RE V I S I O N S 1 2 3 4 5 6 AT T E N T I O N Th i s d o c u m e n t o r a n y p a r t t h e r e o f i n d e t a i l o r d e s i g n c o n c e p t is t h e p r o p e r t y o f E a g l e R o c k E n g i n e e r i n g a n d s h a l l n o t b e co p i e d i n a n y f o r m w i t h o u t t h e w r i t t e n a u t h o r i z a t i o n o f E a g l e Ro c k E n g i n e e r i n g . E SH E E T N O . SH E E T N A M E CI V I L P L A N N I N G S U R V E Y I N G ID A H O F A L L S ( 2 0 8 ) 5 4 2 - 2 6 6 5 RE X B U R G ( 2 0 8 ) 3 5 9 - 2 6 6 5 PR E P A R E D F O R : BR A N T L E Y B R O O K S FR I E N D S H I P E S T A T E S S I T E P L A N A. S N A R R R. J O R D A N P. S N A R R 22 0 4 6 P R E L I M I N A R Y N O T A P P R O V E D F O R C O N S T R U C T I O N 16 4 1 0 BTM BOTTOM CB CATCH BASIN CO CLEAN-OUT CONC CONCRETE DIA DIAMETER ELEV ELEVATION EO EDGE OF OIL FL FLOW LINE FW FACE OF WALK HORZ HORIZONTAL IFS CITY OF REXBURG STANDARDS INV INVERT LF LINEAR FEET MAX MAXIMUM MH MANHOLE MIN MINIMUM MX MATCH EXISTING OSHA OCCUPATIONAL SAFETY & HEALTH ADMINISTRATION PC POINT OF CURVATURE PT POINT OF TANGENT P.U.E.PUBLIC UTILITY EASEMENT PVC POLYVINYL CHLORIDE REQ'D REQUIRED MH MANHOLE SD STORM DRAIN SSMH SANITARY SEWER MANHOLE STA STATIONING TBC TOP BACK OF CURB TYP TYPICAL VERT VERTICAL VG VALLEY GUTTER X EXISTING XG EXISTING GROUND ABBREVIATIONS: DESCRIPTION PRESSURE LINE (WATER LINE) SANITARY SEWER MAIN LINETYPE FENCE LINE OHP OVERHEAD POWER LINE PROPOSED/EXISTING ELEVATION PROPOSED/EXISTING FIRE HYDRANT PROPOSED/EXISTING VALVE PROPOSED/EXISTING CURB AND GUTTER PROPOSED/EXISTING STREET LIGHT PROPOSED/EXISTING POWER POLE EXIST.PRO.DESCRIPTION PROPOSED/EXISTING MANHOLE PROPOSED/EXISTING STORM DRAIN INLET PROPOSED ASPHALT DRAINAGE FLOW ARROW LEGEND 0.75% BOUNDARY LINE CENTERLINE SECTION LINE CONCRETE EXISTING GROUND CONTOUR4727 8" W ( 8" SS TBC 72.1 0 XG = 7 2 . 1 0 PUBLIC UTILITY EASEMENT STORM DRAIN MAIN SD GENERAL NOTES: 1.UNLESS OTHERWISE SHOWN ON THESE PLANS ALL WORK IS TO BE PERFORMED IN ACCORDANCE TO CURRENT CITY OF REXBURG STANDARD DRAWINGS AND SPECIFICATIONS. THE CONTRACTOR IS REQUIRED TO MAINTAIN A COMPLETE COPY ON SITE AT ALL TIMES (RESOLUTION 2016-15). 2.ALL DISTANCES AND DATA SHALL BE CHECKED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. IN CASE OF CONFLICT THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY SO THAT CLARIFICATION MAY BE MADE PRIOR TO THE START OF WORK. 3.BASIS OF BEARINGS ARE 2004 CITY GRID. 4.ELEVATIONS SHOWN ARE NAVD 88 DATUM TO FINISHED SURFACE OR PIPE INVERT UNLESS OTHERWISE NOTED. 5.GENERAL LOCATIONS AND SIZES OF UTILITIES ARE SHOWN ON THE PLANS. THEY ARE TO BE USED FOR GENERAL INFORMATION ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE APPROPRIATE UTILITY COMPANIES WHEN CONSTRUCTION MIGHT INTERFERE WITH NORMAL OPERATIONS OF ANY UTILITIES. IT SHALL ALSO BE THE CONTRACTORS RESPONSIBILITY TO HAVE THE APPROPRIATE UTILITY COMPANY FIELD-LOCATE ANY UTILITY INSTALLATIONS WHICH MIGHT BE AFFECTED BY CONSTRUCTION PRIOR TO BEGINNING WORK IN THAT AREA. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING SERVICE OF EXISTING UTILITIES AND FOR RESTORING ANY UTILITIES DAMAGED DUE TO CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER. 6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING SOURCES FOR GRANULAR MATERIAL, DISPOSAL SITES, AND ANY ADDITIONAL MATERIAL THAT MAY BE NECESSARY FOR PROPER CONSTRUCTION OF THIS PROJECT. 7.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE ARRANGEMENTS FOR WATER REQUIRED FOR TESTING, COMPACTION AND DUST CONTROL MEASURES. 8.ROCK EXCAVATION MAY BE ENCOUNTERED DURING UTILITY CONSTRUCTION. EVERY EFFORT WAS MADE TO REDUCE UTILITY DEPTH WHILE STILL MEETING REGULATORY REQUIREMENTS. FOR BIDDING PURPOSES CONTACT OWNER FOR TEST HOLE DEPTH OF ROCK. 9.LITTLE DEMOLITION IS REQUIRED ON THIS PROJECT PRIOR TO JOB START. CONTRACTOR/BIDDER TO WALK JOB AND IDENTIFY MINOR DEMOLITION WORK PRIOR TO BIDDING. 10.ALL UTILITY MAIN LINES (WATER, SANITARY SEWER AND STORM DRAINAGE) WITHIN PUBLIC STREETS WILL BE OWNED AND MAINTAINED BY THE CITY AND CONSTRUCTED TO CURRENT CITY OF REXBURG STANDARD DRAWINGS AND SPECIFICATIONS; INSPECTED AND CERTIFIED BY AN ENGINEER, LICENSED IN THE STATE OF IDAHO; AND HAVE “AS-BUILT” DRAWINGS PROVIDED TO THE CITY ENGINEER. FAILURE TO COMPLY WITH THE REQUIREMENTS OF THIS PLAN MAY RESULT IN THE CITY'S WITHHOLDING OF BUILDING PERMITS, CERTIFICATE OF OCCUPANCY, AND WATER OR ELECTRICAL SERVICE. 11.LANDSCAPING SIGNS NOT TO EXCEED 3 FEET IN HEIGHT IN THE CLEAR SIGHT TRIANGLE. 12.THERE SHALL BE A 15-FOOT WIDE PUBLIC UTILITY EASEMENT WITHIN EACH LOT ALONG ALL ROAD/STREET FRONTAGES FOR POWER, PHONE, CABLE, GAS, ETC. (GAS REQUIRES SEPARATE TRENCH). THE EXACT LOCATION OF TRANSFORMERS AND PHONE BOXES WILL BE FIELD DETERMINED BY EACH UTILITY COMPANY AFTER ROADS/STREETS HAVE BEEN CONSTRUCTED TO SUBGRADE AND SIDE SLOPES HAVE BEEN COMPLETED. 13.LUMEN/CENTURY LINK/SPARKLIGHT USES THE SAME TRENCH AS ROCKY MOUNTAIN POWER AND REQUIRES CONDUITS (CONTRACTOR SHALL NOTIFY ALL FOR SCHEDULING). POWER DESIGN SHOWN IS PRELIMINARY AND ANY CONSTRUCTION STAKING OF POWER SHALL BE CONFIRMED WITH ROCKY MOUNTAIN POWER FOR FINAL LAYOUT. VERIFY CONDUIT SIZE MEETING ROCKY MOUNTAIN POWER DESIGN PRIOR TO CONSTRUCTION. 14.ALL UTILITIES INCLUDING POWER, PHONE, CABLE, ETC. EXCEPT NATURAL GAS MAY BE IN THE SAME TRENCH. NATURAL GAS MUST BE IN A SEPARATE TRENCH. 15.A 12” SPACING SHALL BE REQUIRED BETWEEN DIFFERENT UTILITIES IN THE SAME TRENCH. 16.CONTRACTOR SHALL CONTACT DIG-LINE AT 811, (800) 342-1585 OR (208) 342-1585 PRIOR TO ANY UTILITY CONSTRUCTION. WATER NOTES: 1.ALL WATER MAINS, SERVICES, AND ALL APPURTENANCES SHALL MEET CURRENT CITY OF REXBURG STANDARD DRAWINGS AND SPECIFICATIONS. THIS SHALL INCLUDE ALL MATERIALS, LABOR, AND INSTALLATION INCLUDING VERTICAL AND HORIZONTAL SEPARATION DISTANCES AND SLOPE REQUIREMENTS. 2.ALL WATER MAIN LINE SHALL BE CLASS 50 DUCTILE IRON MEETING AWWA C-151. 3.MINIMUM COVER OVER ALL WATER LINES SHALL BE 6 FEET. 4.WATER LINE SHALL HAVE A MINIMUM SEPARATION DISTANCE OF TEN (10) FEET FROM ANY SANITARY SEWER OR STORM SEWER MEASURED FROM THE OUTSIDE OF EACH PIPE AS OUTLINED IN THE ISPWC 2020 STANDARD DRAWING SD-407. CROSS AT APPROXIMATELY RIGHT ANGLES WITH FULL PIPE SECTIONS AND MINIMUM OF 1.5 FEET OF VERTICAL SEPARATION. 5.THRUST BLOCKS SHALL BE PLACED AT ALL DIRECTION CHANGES FOR PRESSURE PIPE. 6.FIRE HYDRANTS SHALL HAVE TWO 2-1/2” DIAMETER HOSE NOZZLES AND ONE 4-1/2” DIAMETER HOSE NOZZLE PER CITY STANDARDS. 7.WATER AND SEWER SERVICE LINES ARE SHOWN AT APPROXIMATE LOCATIONS. CONTRACTOR TO CONTACT DIG LINE PRIOR TO ALL EXCAVATION AND FIELD VERIFY LOCATION AND WITH ARCHITECTURAL DRAWINGS (IF APPLICABLE) FOR ANY ADDITIONAL SERVICES REQUIRED. 8.WATER METERS AND PRESSURE REDUCING VALVES - SEE PLUMBING DRAWINGS FOR DETAILS. ALL PLUMBING SHALL MEET THE STATE OF IDAHO PLUMBING CODE. COMMERCIAL BUILDINGS SHALL REQUIRE THE WATER METERS TO BE INSTALLED ON THE INTERIOR AND MOUNTED IN A HORIZONTAL POSITION WITHIN A HEATED MECHANICAL ROOM. 9.CONTRACTOR SHALL INSTALL FIRE LINES/SPRINKLERS MEETING THE CURRENT VERSION OF THE INTERNATIONAL FIRE CODE AND SHALL INCLUDE ALL APPURTENANCES (IF APPLICABLE). 10.IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE AND INSTALL ALL REQUIRED BACKFLOW PREVENTION DEVICES ON WATER SERVICES. 11.ALL WATER MAINS AND APPURTENANCES SHALL BE TESTED FOR PRESSURE, LEAKAGE, AND BACTERIA MEETING CITY AND AWWA STANDARDS AND SHALL BE CLEANED AND DISINFECTED PRIOR TO ACCEPTANCE BY THE CITY FOR DOMESTIC USE. TESTING AND DISINFECTION OF WATER MAINS AND APPURTENANCES SHALL BE IN ACCORDANCE WITH AWWA C651 STANDARDS. AWWA STANDARDS REQUIRE EACH STREET TO BE TESTED INDIVIDUALLY FOR PRESSURE, LEAKAGE, AND BACTERIA. SANITARY SEWER NOTES: 1.ALL SEWER MAIN SHALL BE PVC SDR 35 IN ACCORDANCE WITH ASTMD3034 WATER MAIN AND SERVICE SHALL MEET CURRENT CITY OF REXBURG STANDARD DRAWINGS AND SPECIFICATIONS. THIS SHALL INCLUDE ALL MATERIALS, LABOR, AND INSTALLATION INCLUDING VERTICAL AND HORIZONTAL SEPARATION DISTANCES AND SLOPE REQUIREMENTS. 2.SEPARATION REQUIREMENTS: WATER LINE SHALL HAVE A MINIMUM SEPARATION DISTANCE OF TEN (10) FEET FROM ANY SANITARY SEWER OR STORM SEWER MEASURED FROM THE OUTSIDE OF EACH PIPE AS OUTLINED IN THE ISPWC 2020 STANDARD DRAWING SD-407. CROSS AT APPROXIMATELY RIGHT ANGLES WITH FULL PIPE SECTIONS AND MINIMUM OF 1.5 FEET OF VERTICAL SEPARATION. 3.CONTRACTOR SHALL PERFORM TESTING AND CLEANING OF SEWER MAINS MEETING CITY STANDARDS. SHEET INDEX SHEET No.SHEET DESCRIPTION SHEET TITLE 1 G-1 COVER 2 C-1 OVERALL SITE PLAN June 2022 VICINITY MAP ELECTRICAL NOTES: 1.ALL NEW ELECTRICAL FACILITIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENT ROCKY MOUNTAIN POWER SERVICE POLICY. 2.DEVELOPER SHALL BEAR ALL COSTS TO RELOCATE OR REMOVE EXISTING POWER POLES, LIGHT POLES, ANCHOR GUYS AND MISCELLANEOUS ELECTRICAL FACILITIES. 3.ALL PVC ELECTRIC CONDUITS SHALL BE PVC SCHEDULE 40. ALL FIBERGLASS CONDUITS SHALL MEET ROCKY MOUNTAIN POWER'S MARKING AND STRENGTH RATING REQUIREMENTS. CONDUIT DIAMETERS SHALL MEET ROCKY MOUNTAIN POWER'S DESIGN. ALL ELBOWS SWEEP RADII SHALL BE 36”, 48” OR 60” DEPENDING ON ROCKY MOUNTAIN POWER'S DESIGN. 4.ALL PRIMARY AND SECONDARY CONDUITS SHALL BE PROVIDED AND INSTALLED BY THE DEVELOPER. 5.TRENCH EXCAVATION AND CONDUIT PLACEMENT SHALL BE IN ACCORDANCE WITH ROCKY MOUNTAIN POWER SERVICE POLICY SPECIFICATIONS AND IN ACCORDANCE WITH OSHA STANDARDS. CONDUIT TRENCH DEPTHS SHALL BE BETWEEN 36” AND 48” (NOT TO EXCEED 60”) AND INCLUDE THE REQUIRED SAND PLACEMENT BELOW AND ABOVE THE PLACED CONDUIT. 6.THE ENGINEER SHALL PROVIDE ALL STAKING AND LAYOUT OF NEW ELECTRICAL FACILITIES INCLUDING POWER POLES. 7.THE CONTRACTOR SHALL RETAIN AND PROTECT ALL EXISTING POWER POLES AND ELECTRICAL FACILITIES DURING CONSTRUCTION. 8.THE DEVELOPER SHALL COORDINATE ALL ELECTRICAL CONSTRUCTION WITH ROCKY MOUNTAIN POWER. 9.CLEARANCE BETWEEN OVERHEAD POWER AND NEW BUILDING STRUCTURES SHALL BE MAINTAINED MEETING THE CURRENT ROCKY MOUNTAIN POWER SERVICE POLICY. 10.SEE ROCKY MOUNTAIN POWER ELECTRICAL SITE PLAN FOR OFF-SITE AND ON-SITE ELECTRICAL LAYOUT AND INSTALLATION DETAILS. IN THE EVENT THE FIBER OPTIC UTILITY ELECTS TO USE THE SAME TRENCH, THEY MUST MEET NESC UNDERGROUND UTILITY CLEARANCES. 11.A 15 FOOT WIDE PUBLIC UTILITY EASEMENT IS PERPETUALLY RESERVED WITHIN EACH LOT ALONG ALL ROAD FRONTAGES FOR THE USE OF PUBLIC UTILITIES WITHIN THIS SUBDIVISION. NO PERMANENT STRUCTURES, SIDEWALKS, AND DRIVEWAYS SHALL BE CONSTRUCTED OVER SAID EASEMENT (OTHER THAN CROSSINGS) IN ORDER FOR THE UTILITY COMPANIES TO MAINTAIN. EAST 2ND NORTH NO R T H 4 T H E A S T HOUSE C O R P O F T H E P R E S I D I N G I N S T R U M E N T N o . 1 3 6 3 7 3 S89°44'58"W 230.00' N89°44'58"E 230.00' N0 ° 1 5 ' 0 2 " W 1 3 0 . 4 3 ' 1 5000 SF 0.115 AC. 6 5000 SF 0.115 AC. 5 5000 SF 0.115 AC. 4 5000 SF 0.115 AC. 3 5000 SF 0.115 AC. 2 5000 SF 0.115 AC. S0 ° 1 5 ' 0 2 " E 1 3 0 . 4 3 ' 20 ' P . U . E . F O R SE W E R L I N E SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD OHPOHPOHPOHPOHPOHPOHP OHP SS SS SS SS SS X X X X X X X X X X X X X X X X X X X X X X X WWWWWWWWWWWWWWWWWWWWWW W W W W W W W W W W W W W W W W W (8''SS (8''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 6''SS 4' ' S S 4' ' S S 4' ' S S 4' ' S S 4' ' S S 4 8 7 3 4874 4873 487 2 48 7 2 4872 4 8 7 2 48 7 4 4 8 7 3 0+00 1+00 2+00 3+003+00 1 1 1 1 1 1 2 2 2 2 2 2 TREE LINE (TYP.) REMOVE TREES AS NECESSARY FOR SS INSTALLATION 1 TIE NEW SIDEWALK ONTO EXISTING (MATCH EXISTING GRADE) 1 7' 3 3 3 3 3 4" SS SERVICE LINE TO LOT 1 3 4864 4866 4868 4870 4872 4864 4866 4868 4870 4872 0+00 1+00 2+00 3+003+00 8" E INV IN=4865.85 8" S INV OUT=4865.75 EX. SSMH STA=0+15.45, 6.75' R RIM=4873.00 6" E INV IN=4866.23 8" W INV OUT=4866.06 SSMH 1 STA=0+67.76, 0.00' RIM=4873.18 6" E INV IN=4867.23 6" W INV OUT=4867.23 CLEAN-OUT 2 STA=1+68.10, 0.00' R RIM=4872.93 6" W INV OUT=4868.22 CLEAN-OUT STA=2+67.76, 0.00' RIM=4872.37 53-LF OF 8" PVC @ 0.40% 50-LF OF 6" PVC @ 1. 0 0 % 23-LF OF 6" PVC @ 1.00% SSMH 1 END OF PUBLIC SS PRIVATE 6" SS 6" E INV IN=4866.73 6" W INV OUT=4866.73 CLEAN-OUT 1 STA=1+18.10, 0.00' R RIM=4873.33 6" E INV IN=4867.61 6" W INV OUT=4867.61 CLEAN-OUT 3 STA=2+06.43, 0.00' R RIM=4872.78 6" E INV IN=4867.99 6" W INV OUT=4867.99 CLEAN-OUT 4 STA=2+44.76, 0.00' R RIM=4872.5450-LF OF 6" PVC @ 1. 0 0 % 38-LF OF 6" PVC @ 1. 0 0 % 38-LF OF 6" PVC @ 1 . 0 0 % Fi l e L o c a t i o n : z: \ p r o j e c t s \ 2 0 2 2 \ 2 2 0 4 6 b r a n t l e y b r o o k s s u b d i v i s i o n \ 3 . 0 d e s i g n \ 3 . 1 c a d \ 3 . 1 3 f i n a l \ 2 2 0 4 6 s p o v e r a l l s i t e p l a n . d w g Pl o t t e d B y : ru s s e l l Da t e P l o t t e d : Th u r s d a y , J u n e 2 3 2 0 2 2 a t 0 9 : 0 4 A M W E S N 020'20'10' SCALE: 1" = 20' 2 C- 1 OV E R A L L S I T E P L A N AG L E R O C K N G I N E E R I N G SU R V E Y E D B Y : DR A W N B Y : PR O J E C T N O . AP P R O V E D B Y : DE S C R I P T I O N DA T E RE V I S I O N S 1 2 3 4 5 6 AT T E N T I O N Th i s d o c u m e n t o r a n y p a r t t h e r e o f i n d e t a i l o r d e s i g n c o n c e p t is t h e p r o p e r t y o f E a g l e R o c k E n g i n e e r i n g a n d s h a l l n o t b e co p i e d i n a n y f o r m w i t h o u t t h e w r i t t e n a u t h o r i z a t i o n o f E a g l e Ro c k E n g i n e e r i n g . E SH E E T N O . SH E E T N A M E CI V I L P L A N N I N G S U R V E Y I N G ID A H O F A L L S ( 2 0 8 ) 5 4 2 - 2 6 6 5 RE X B U R G ( 2 0 8 ) 3 5 9 - 2 6 6 5 PR E P A R E D F O R : BR A N T L E Y B R O O K S FR I E N D S H I P E S T A T E S S I T E P L A N A. S N A R R R. J O R D A N P. S N A R R 22 0 4 6 P R E L I M I N A R Y N O T A P P R O V E D F O R C O N S T R U C T I O N 16 4 1 0 15' P.U.E. (TYP.) GASKET ALL JOINTS CONCRETE COLLAR FINISHED GRADEFRAME & COVER 45° FL O W SH E L F SHE L F SHE L F MANHOLE NOTES: 5" FLEXIBLE RUBBER GASKET PRECAST MONOLITHIC CONCENTRIC CONE SECTION PRECAST CONCRETE MANHOLE-BARREL SECTIONS AS REQ'D PREFABRICATED BASE. UNDISTURBED EARTH A 4 A P P R O V E D BE D D I N G 6" MIN31 " 48" DIA 9 M I N RUBBER BOOT .7 5 X D i P I P E 1.PLACE VERTICAL WALL ON UPSTREAM SIDE OF MANHOLE, ROTATED 45 DEGREES. 2.WHERE PVC PIPE IS UTILIZED, INSTALL A RUBBER RING OR GASKET COLLAR WHERE THE PIPE IS IN CONTACT WITH MANHOLE BASE AND/OR MANHOLE CHANNEL, IN ORDER TO INSURE A WATERTIGHT SEAL. 3.UNLESS OTHERWISE SHOWN, MANHOLES SHALL HAVE 0.1 FALL FROM UPSTREAM INVERT TO DOWNSTREAM INVERT. FOR PIPE SLOPES GREATER THAN 2.5% SLOPE, SEE PLAN & PROFILE. PLAN DETAIL NOT TO SCALE SEWER MANHOLE SECTION1 NOT TO SCALE TYPICAL SEWER TRENCH DETAIL2 12" (MIN.) UNDISTURBED EARTH (TYP.) EXISTING BASE FOUNDATION STABILIZATION TYPE I BEDDING MATERIAL PIPE TRENCH BACK SLOPE PER O.S.H.A. OR SUITABLE SHORING. UPPER & LOWER BACKFILL ZONE MATERIAL & COMPACTION TO MATCH REQUIREMENTS OF STORM DRAIN TRENCH SECTION (DETAIL 1/SD-1). LOWER BACKFILL ZONE. MATERIAL & COMPACTION TO MATCH REQUIREMENTS OF LOWER BACKFILL ZONE OF STORM DRAIN PIPE SECTION. DETAIL (1/SD-1). FINISH GRADE SURFACE REPAIR WIDTH OR LOCAL CUT BACK REQUIREMENTS TYPICAL BOTH SIDES. EXISTING SURFACENEW PAVEMENT SECTION Do+24" SE E N O T E 2 VA R I E S P E R PI P E S I Z E 2' - 6 " VA R I E S 0. 3 5 ' M I N 0. 5 4 ' M I N Do SUBGRADE OR NATURAL GROUND LID & COVER 1.GALVANIZED STAND PIPE 32 INCHES WRAPPED WITH TAPE. 2.ALL SERVICE LINES SHALL BE BORED UNDER EXISTING ASPHALT PAVING. NO ASPHALT PAVING SHALL BE CUT FOR SERVICE LINE INSTALLATION. 3.ALL SUPPLIES PROVIDED BY CITY EXCEPT CORPORATION CURB STOP, METER SUPPORT, SUPPLY LINES IN & OUT. GENERAL NOTES:4" LAWN LEVEL METER TOUCH READ BUTTON SERVICE LINE METER SUPPORT STRAP SERVICE LINE TO METER SUPPORT 2" MIN HOUSE SIDE GALVANIZED PIPE, CONNECT TO METER & ANGLE METER VALVE W/APPROXIMATE FITTINGS SEE NOTE 1 20" X 48" POLY BARREL 20" RING AND COVER W/ TOUCH READ HOLE BALL TYPE CORPORATION AND CURB STOP ADAPTER, POLY-BY-FEMALE METAL PIPE RATED AT 300 PSI MINIMUM WORKING PRESSURE. NOT TO SCALE 1 1/2" METER AND METER SETTING DETAIL3 SEWER MANHOLE SEE STANDARD MANHOLE DETAIL 1. COVER MUST SAY "CITY OF REXBURG AND CONFINED SPACE ENTRY" 4" SANITARY SEWER SERVICE GENERAL NOTES SEWER CONSTRUCTION NOTES 1 2 WATER CONSTRUCTION NOTES 1 INSTALL 1" WATER SERVICE PER LATEST REVISION OF ISPWC STANDARD DETAIL DRAWINGS SD-401 (TYP) SANITARY SEWER PROFILE OVERALL SITE INSTALL 5' SIDEWALK PER CITY OF REXBURG STANDARDS. (4" THICK WITH A 6" BASE COARSE MINIMUM)1 INSTALL SANITARY SEWER CLEAN-OUT3