Loading...
HomeMy WebLinkAboutConnections_Rexburg-ResponseAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Don Allen Don.Allen@rexburg.org 208-372-2174 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Connections Therapy Address : 450 First American Cir Application Type : Document Filename : Connections_Rexburg.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G002 Free Text Cody Jones : Building Open 3 Penetrations comply with IBC Section 714 for rated assemblies G002 Free Text Cody Jones : Building Open 3 Ducts and dampers meet the requirements of IBC Section 717 G002 Free Text Cody Jones : Building Open 3 Concealed spaces are fireblocked/draftstopped per Section 718 G002 Free Text Cody Jones : Building Open 3 Accessible Means of Egress complies with IBC Section 1009 G002 Note Cody Jones : Building Open 3 Recreational Facilities comply with IBC Section 1110 G002 Note Cody Jones : Building Open 3 Electrical: Exit Signs/Emergency Lighting G003 Free Text Cody Jones : Building Open 4 Fire barrier to comply with Section 707 and continuity of 707.5. A0.00 Free Text Cody Jones : Building Open 5 86 parking stalls would require 4 ADA accessible stalls with at least one of those being van accessible. 1106.1, 1106.5. A1.1 Free Text Cody Jones : Building Open 9 2 hour rated wall to have listed assembly specified. A1.1 Free Text Cody Jones : Building Open 10 Egress width 68" A5.1 Free Text Cody Jones : Building Open 42 As per section 1003.1 a barrier shall be provided where the vertical clearance above a circulation path is less than 80" high above finished floor. # 23-00172 New Commercial Building Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 04.26.2023 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A7.1 Note Cody Jones : Building Open 56 Panic Hardware shall be installed as per IBC Section 1010.1.10 A8.2 Free Text Cody Jones : Building Open 60 Suspended ceiling to be installed to manufacturers specifications. S1.0 Note Cody Jones : Building Open 62 Roof and Roof Fire Classification comply with IBC Chapter 15 S1.1 Free Text Cody Jones : Building Open 63 Special inspector needs to be identified as per Chapter 17. S1.2 Note Cody Jones : Building Open 64 Rebar: 8' Wall-Horizontal & Vertical 24" O.C. with 2 in Top 12" Rebar: 4' Wall-Horizontal & Vertical 24" O.C. with 1 in Top 6" E-5.1 Callout Alex Owens : Electrical Open 121 Available fault current calculation needed E-5.1 Callout Alex Owens : Electrical Open 121 Available fault current calculations needed for service and panels E-5.1 Callout Alex Owens : Electrical Open 121 2 runs parallel 350 aluminum conductors is not adequate feeder size for 600 amps. Report Date: 04.26.2023 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org)