HomeMy WebLinkAbout07-230523-J23012.00-ELECTRICAL-CONNECTIONS THERAPY-REXBURG, IDDESIGN CONTACTS COMMISSIONING NOTES: ’ ELECTRICAL GENERAL NOTES: ABBREVIATIONS INDEX ɸ ɸ ɸ ELECTRICAL SYMBOLS SHEET INDEX ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:03/31/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-0.1 ELECTRICAL COVER SHEET N SITE ELECTRICAL PLAN ELECTRICAL KEYED NOTES: ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:05/09/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-0.2 04/21/20231 ADDENDUM 1 05/01/20232 CITY COMMENTS 3 05/08/2023 REVISION SITE ELECTRICAL PLAN N SITE PHOTOMETRIC PLAN ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:03/31/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-0.3 SITE PHOTOMETRIC PLAN N FIRST FLOOR POWER PLAN WAITING 104 VESTIBULE 103 RECEPT. 105 KIDS 106 R.R. W/ SHOWER 117 OT / PT TESTING / TREATMENT 127 PT TREATMENT 126 ADL KITCHEN 118 ADL PANTRY 119 ADL FAMILY / LAUNDRY / BED RM. 116 CONSTRUCTION / CRAFT ZONE 115 OT / PT TREATMENT 129 I.T. 113 STAFF R.R. 131 EVENT STORAGE 137 QUIET 130 JAN. 124 TECHNOLOGY 111 TESTING 109 WOMENS 133 CONSULT 108 MENS 132 GYM 122 UNISEX R.R. 123 PT 125 STORAGE 121 SENSORY RM. 120 FIRE RISER 112 HALLWAY ? VESTIBULE 101 STAIR 134 STAIR 114 EVENT CENTER 136 FOOD PREP ROOM 139 ENTRANCE LOBBY 102 PLAYGROUND 141 OUTDOOR PATIO 140 ADMIN. STORAGE 110 JAN. / STORAGE 138 EVENT I.T. 135 ADMIN. 107 ELECTRICAL RM. 128 ELECTRICAL KEYED NOTES: ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:04/21/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-1.1 04/21/20231 ADDENDUM 1 1ST FLOOR POWER PLAN N SECOND FLOOR POWER PLAN GENERAL NOTES: STAIR 206 UNISEX 203 LOUNGE 201 MENS 209 WOMENS 208 SPEECH 2 231 SPEECH 1 233 SPEECH 8 229 SPEECH 16 214 SPEECH 4 232 SPEECH 5 230 SPEECH 6 228 SPEECH 7 226 SPEECH 9 227 SPEECH 14 217 SPEECH 13 219 SPEECH 10 225 SPEECH 11 223 SPEECH 12 222 CONSTRUCTION / CRAFT ZONE 220 OT /PT TREATMENT 218 SPEECH 17 216 OT /PT TREATMENT 213 STORAGE 211 STAIRS 224 MEZZANINE 212 STOR. 221 EVENT FAMILY 202 EVENT FAMILY 204 SPEECH 3 234 SPEECH 15 215 STAFF R.R. 210 MOTHERS RM. 207 HALLWAY 235 JAN. 205 ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:03/31/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-1.2 SECOND FLOOR POWER PLAN N THIRD FLOOR POWER PLAN GENERAL NOTES: STAIR 315 RECEPT. / WAITING 302 STORAGE / JAN. 314 ELEVATOR LOBBY 301 EX, OFFICE 306 CONNECTIONS OFFICE 330 CONNECTION OFFICE 326 CONNECTIONS OFFICE 328 CONNECTION OFFICE 323 STAIR 332 MOTHERS RM. 316 CONFERENCE 324 OFFICE 307 BKR. 312 IT / COPY / PRINT WORK 304 PANTRY / STORAGE 319 STORAGE 321 BKR 320 OUTDOOR PATIO 325 MENS 318 WOMENS 317 CONNECTION OFFICE 322 OFFICE 311 OFFICE 310 OFFICE 308 CONF. 305 OFFICE 309 HALLWAY 303 HALLWAY 331 UNISEX R.R. 327 COPY, PRINT 329 IT 313 ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:03/31/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-1.3 THIRD FLOOR POWER PLAN N ROOF POWER PLAN GENERAL NOTES: ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:03/31/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-1.4 ROOF POWER PLAN N FIRST FLOOR LIGHTING PLAN GENERAL NOTES: VESTIBULE 103 RECEPT. 105 KIDS 106 R.R. W/ SHOWER 117 OT / PT TESTING / TREATMENT 127 PT TREATMENT 126 ADL KITCHEN 118 ADL PANTRY 119 ADL FAMILY / LAUNDRY / BED RM. 116 CONSTRUCTION / CRAFT ZONE 115 OT / PT TREATMENT 129 I.T. 113 STAFF R.R. 131 EVENT STORAGE 137 QUIET 130 JAN. 124 TECHNOLOGY 111 TESTING 109 WOMENS 133 CONSULT 108 MENS 132 GYM 122 UNISEX R.R. 123 PT 125 STORAGE 121 SENSORY RM. 120 FIRE RISER 112 HALLWAY VESTIBULE 101 STAIR 134 STAIR 114 EVENT CENTER 136 FOOD PREP ROOM 139 ENTRANCE LOBBY 102 PLAYGROUND 141 OUTDOOR PATIO 140 ADMIN. STORAGE 110 JAN. / STORAGE 138 EVENT I.T. 135 ADMIN. 107 ELECTRICAL RM. 128 ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:03/31/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-1.5 FIRST FLOOR LIGHTING PLAN N SECOND FLOOR LIGHTING PLAN GENERAL NOTES: STAIR 206 UNISEX 203 LOUNGE 201 MENS 209 WOMENS 208 SPEECH 2 231 SPEECH 1 233 SPEECH 8 229 SPEECH 16 214 SPEECH 4 232 SPEECH 5 230 SPEECH 6 228 SPEECH 7 226 SPEECH 9 227 SPEECH 14 217 SPEECH 13 219 SPEECH 10 225 SPEECH 11 223 SPEECH 12 222 CONSTRUCTION / CRAFT ZONE 220 OT /PT TREATMENT 218 SPEECH 17 216 OT /PT TREATMENT 213 STORAGE 211 STAIRS 224 MEZZANINE 212 STOR. 221 EVENT FAMILY 202 EVENT FAMILY 204 SPEECH 3 234 SPEECH 15 215 STAFF R.R. 210 MOTHERS RM. 207 HALLWAY 235 JAN. 205 GYM 122 ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:03/31/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-1.6 SECOND FLOOR LIGHTING PLAN N THIRD FLOOR LIGHTING PLAN GENERAL NOTES: STAIR 315 RECEPT. / WAITING 302 STORAGE / JAN. 314 ELEVATOR LOBBY 301 EX, OFFICE 306 CONNECTIONS OFFICE 330 CONNECTION OFFICE 326 CONNECTIONS OFFICE 328 CONNECTION OFFICE 323STAIR 332 MOTHERS RM.316 CONFERENCE 324 OFFICE 307 BKR. 312 IT / COPY /PRINT WORK 304 PANTRY / STORAGE 319 STORAGE 321 BKR 320 OUTDOOR PATIO 325 MENS 318 WOMENS 317 CONNECTION OFFICE 322 OFFICE 311 OFFICE 310 OFFICE 308 CONF. 305 OFFICE 309 HALLWAY 303 HALLWAY 331 UNISEX R.R. 327 COPY, PRINT 329 IT 313 ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:03/31/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-1.7 THIRD FLOOR LIGHTING PLAN FIRE ALARM RISER DIAGRAM FACP NOTES: KEYED NOTES: 1 ALUMINUM FEEDER SCHEDULE EQUIPMENT GROUNDING CONDUCTORS SCHEDULE POWER ONE-LINE DIAGRAM2 COPPER FEEDER SCHEDULE EQUIPMENT GROUNDING CONDUCTORS SCHEDULE KEYED NOTES: ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:05/23/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-5.1 04/21/20231 ADDENDUM 1 05/01/20232 CITY COMMENTS 3 05/08/2023 REVISION 4 05/23/2023 CITY COMMENTS 2 ELECTRICAL DETAILS ENTRANC LOBBY 102 ELEVATO LOBBY 301 ENLARGED ELEVATOR PLAN ELEVATOR KEYED NOTES: ADA TWO-WAY COMMUNICATIONS SYSTEM RISER DIAGRAM KEYED NOTES: HEAT CABLE CONTROL DETAIL GENERAL NOTES: 2 4 3 VIDEO MONITOR WIRING DETAIL SECTION CUT ELEVATION GENERAL NOTE: 5 COMMUNICATIONS RISER DIAGRAM1 ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:04/21/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-5.2 04/21/20231 ADDENDUM 1 ELECTRICAL DETAILS MOTION SENSOR WITH LV SWITCH3 ELECTRIC WATER COOLER INSTALLATION DETAIL REGULAR ACCESSIBLE 4 ROUGH-IN DETAIL FOR MC CABLE KEYED NOTES: GENERAL NOTES: 6 TYPICAL RECESSED FIXTURE MOUNTING DETAIL1 DEVICE MOUNTING HEIGHTS INSTALLATION DETAIL8 KEYED NOTES: ELECTRICAL EQUIPMENT WORK SPACE CLEARANCES GENERAL NOTE: 5 DATA/VOICE JACK INSTALLATION DETAIL KEYED NOTES:GENERAL NOTES: 2 ROUGH-IN DETAIL FOR CONDUIT GENERAL NOTES: 7 ROUGH-IN DETAIL FOR MEDICAL GRADE MC CABLE KEYED NOTES: GENERAL NOTES: 9 ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:03/31/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-5.3 ELECTRICAL DETAILS SERVICE GROUNDING DETAIL KEYED NOTE:NOTE: 1 VIDEO MONITOR WIRING DETAIL SECTION CUT ELEVATION GENERAL NOTE: 7 WALL PENETRATION FLOOR PENETRATION FIRE RATED PENETRATION DETAIL9 LIGHTING CONTROL WIRING DIAGRAM KEYED NOTE: TRENCHING DETAIL2 WEATHERPROOF RECEPTACLE INSTALLATION DETAIL8 POLE BASE DETAIL POLE BASE DEPTH TABLE 3 ACCESS CONTROL RISER DIAGRAM5 ACCESS CONTROL DOOR LOCK DETAIL4 6 "LCP" ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:03/31/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-5.4 ELECTRICAL DETAILS EQUIPMENT SCHEDULE SYMBOL DESCRIPTION SERVICE DISCONNECT STARTER LOAD MOCP/ BRKR REMARKSVOLTSPHASESIZEFUSEHP/TON VA AMPS FC 1 VRF INDOOR 208 V 1Ø 2 POLE SWITCH -INTEGRAL 312 1.5A 15A FC 2 VRF INDOOR 208 V 1Ø 2 POLE SWITCH -INTEGRAL 374 1.8A 15A FC 3 VRF INDOOR 208 V 1Ø 2 POLE SWITCH -INTEGRAL 125 0.6A 15A FC 4 VRF INDOOR 208 V 1Ø 2 POLE SWITCH -INTEGRAL 707 3.4A 15A FC 5 VRF INDOOR 208 V 1Ø 2 POLE SWITCH -INTEGRAL 125 0.6A 15A FC 6 VRF INDOOR 208 V 1Ø 2 POLE SWITCH -INTEGRAL 333 1.6A 15A FC 7 VRF INDOOR 208 V 1Ø 2 POLE SWITCH -INTEGRAL 603 2.9A 15A FC 8 VRF INDOOR 208 V 1Ø 2 POLE SWITCH -INTEGRAL 312 1.5A 15A FC 9 VRF INDOOR 208 V 1Ø 2 POLE SWITCH -INTEGRAL 312 1.5A 15A FC 10 VRF INDOOR 208 V 1Ø 2 POLE SWITCH -INTEGRAL 582 2.8A 15A FC 11 VRF INDOOR 208 V 3Ø 2 POLE SWITCH -INTEGRAL 648 1.8A 15A FC 12 VRF INDOOR 208 V 3Ø 2 POLE SWITCH -INTEGRAL 1,009 2.8A 15A FC 13 VRF INDOOR 208 V 3Ø 2 POLE SWITCH -INTEGRAL 504 1.4A 15A FC 14 VRF INDOOR 208 V 3Ø 2 POLE SWITCH -INTEGRAL 648 1.8A 15A FC 15 VRF INDOOR 208 V 3Ø 2 POLE SWITCH -INTEGRAL 1,045 2.9A 15A FC 16 VRF INDOOR 208 V 3Ø 2 POLE SWITCH -INTEGRAL 648 1.8A 15A FC 17 VRF INDOOR 208 V 3Ø 2 POLE SWITCH -INTEGRAL 1,225 3.4A 15A FC 18 VRF INDOOR 208 V 3Ø 2 POLE SWITCH -INTEGRAL 216 0.6A 15A FC 19 VRF INDOOR 208 V 3Ø 2 POLE SWITCH -INTEGRAL 216 0.6A 15A FC 20 VRF INDOOR 208 V 3Ø 2 POLE SWITCH -INTEGRAL 576 1.6A 15A FC 21 VRF INDOOR 208 V 3Ø 2 POLE SWITCH -INTEGRAL 1,045 2.9A 15A FC 22 VRF INDOOR 208 V 3Ø 2 POLE SWITCH -INTEGRAL 648 1.8A 15A POWERED FROM OUTDOOR UNIT AC-1a ODU 1 VRF OUTDOOR 208 V 3Ø 60A NEMA 3R -INTEGRAL 13,150 36.5A 40A ODU 2 VRF OUTDOOR 208 V 3Ø 60A NEMA 3R -INTEGRAL 13,150 36.5A 40A ODU 3 VRF OUTDOOR 208 V 3Ø 60A NEMA 3R -INTEGRAL 13,150 36.5A 40A ERV 1 ENERGY RECOVERY VENTILATOR 208 V 3Ø 100A NEMA 3R -INTEGRAL 26,840 74.5A 100A RTU 5 ROOF TOP UNIT 208 V 3Ø 60A NEMA 3R -INTEGRAL 11,529 32.0A 45A FACTORY INSTALLED DISCONNECT AND RECEPTACLE. SAC 1 SPLIT SYSTEM COOLING INDOOR 208 V 3Ø 2 POLE SWITCH -INTEGRAL 360 1.0A -A CONNECTED TO OUTDOOR UNIT FOR POWER SCU 1 SPLIT SYSTEM COOLING OUTDOOR 208 V 1Ø 30A NEMA 3R -INTEGRAL 2,746 13.2A 20A BS 1 BRANCH CIRCUIT CONTROLLER 208 V 1Ø 2 POLE SWITCH -INTEGRAL 166 0.8A 15A BS 2 BRANCH CIRCUIT CONTROLLER 208 V 1Ø 2 POLE SWITCH -INTEGRAL 166 0.8A 15A BS 3 BRANCH CIRCUIT CONTROLLER 208 V 1Ø 2 POLE SWITCH -INTEGRAL 166 0.8A 15A EWH 1 ELECTRIC WALL HEATER 208 V 1Ø T-STAT --1,498 7.2A -A EWH 2 ELECTRIC WALL HEATER 208 V 1Ø T-STAT --1,123 5.4A -A UH 1 UNIT HEATER 120 V 1Ø T-STAT --360 3.0A -A PROVIDE 100 MA CONTROL TRANSFORMER 120 VOLT TO 24 VAC IN A JUNCTION BOX ENCLOSURE MOUNTED IN EVENT CENTER. WH 1 WATER HEATER 120 V 1Ø PLUG/ CORD --120 1.0A -A WH 2 WATER HEATER 120 V 1Ø PLUG/ CORD --120 1.0A -A CP 1 RECIRCULATION PUMP 120 V 1Ø PLUG/ CORD --FRAC 240 2.0A -A SP 1 SUMP PUMP 120 V 1Ø PLUG/ CORD --1,200 10.0A -A EL 1 ELEVATOR 208 V 3Ø 100A NEMA 1 80A -30 HP 18,013 50.0A -A PROVIDE DISCONNECT WITH SHUNT-TRIP CONTROL AND AUXILIARY CONTACT. VERIFY EQUIPMENT AND CONNECTION REQUIREMENTS WITH ELEVATOR SUBMITTALS PRIOR TO ORDERING. NOTES: 1.VERIFY ALL EQUIPMENT LOCATIONS AND CONNECTION REQUIREMENTS (i.e. VOLTAGE, PHASE, FLA, ETC.) WITH MECHANICAL DRAWINGS/SUBMITTALS BEFORE FOR ACTUAL EQUIPMENT INSTALLED. 2.ALL FUSES SHALL BE DUAL ELEMENT TIME DELAY. FINAL BREAKER/FUSE & DISCONNECT SIZE SHALL BE DETERMINED BY MANUFACTURER'S RECOMMENDATION FOR ACTUAL EQUIPMENT INSTALLED. 3.MAXIMUM VALUES INDICATED. 4.DISCONNECTING MEANS NOT REQUIRED FOR EQUIPMENT WITHIN SIGHT (AS DEFINED IN NEC) OF BRANCH PANEL SERVING EQUIPMENT. SEE NEC 422.31 (B). 5.DISCONNECTING MEANS NOT REQUIRED FOR APPLIANCES NOT OVER 300 VA. SEE NEC 422.31 (A). LIGHT FIXTURE SCHEDULE FIXTURE NUMBER FIXTURE MANUFACTURER FIXTURE CATALOG # LAMPS FIXTURE DESCRIPTION REMARKSTYPEQTY.VOLTS WATTS MOUNTING F1 METALUX LITHONIA DAY-BRITE LSI COLUMBIA ORACLE 24AC-LD4-44-UNV-L835-CD1-U 2RTL4-40L-EZ1-LP835 2DLG43L835-4-D-UNV ASC24-LED-SS-WW-UE LEPC24-35LWG-LL-EDU 24-NV-LED-4000L-DIM10-MVOLT-35K-80 LED 3500 KELVIN 3800 LUMENS 80 CRI -120 40.6 LAY-IN GRID 2X4 LED LAY-IN VOLUMETRIC F1E METALUX LITHONIA DAY-BRITE LSI COLUMBIA ORACLE 24AC-LD4-44-UNV-EL14W-L835-CD1-U 2RTL4-40L-EZ1-LP835-EL14L 2DLG43L835-4-D-UNV-EMLED ASC24-LED-SS-WW-UE-EM-1100 LEPC24-35LWG-LL-EDU-ELL14 24-NV-LED-4000L-DIM10-MVOLT-35K-80-O-EMG-LED LED 3500 KELVIN 3800 LUMENS 80 CRI -120 40.6 LAY-IN GRID 2X4 LED LAY-IN VOLUMETRIC WITH EMERGENCY BATTERY PACK F2 ELITE OLS-D1-LED-4-S-4'-U1000L-120-35K-85-WH LED 3500 KELVIN 1000 LUMENS/FT 80 CRI -120 32.8 SUSPENDED LINEAR UP/DOWN 4 FOOT SECTIONS F2A ELITE OLS-D1-LED-4-S-3'-U1000L-120-35K-85-WH LED 3500 KELVIN 1000 LUMENS/FT 80 CRI -120 32.8 SUSPENDED LINEAR UP/DOWN 3 FOOT SECTIONS F2E ELITE OLS-D1-LED-4-S-4'-U1000L-120-35K-85-WH-EM LED 3500 KELVIN 1000 LUMENS/FT 80 CRI -120 32.8 SUSPENDED LINEAR UP/DOWN EMERGENCY 4 FOOT SECTIONS F2EA ELITE OLS-D1-LED-4-S-3'-U1000L-120-35K-85-WH-EM LED 3500 KELVIN 1000 LUMENS/FT 80 CRI -120 32.8 SUSPENDED LINEAR UP/DOWN EMERGENCY 3 FOOT SECTIONS F3 METALUX HBLED-LD5-12SE-W-CL-WG-UNV-L840-CD2-U LED 4000 KELVIN 12000 LUMENS 80 CRI -120 109 PENDANT OR SURFACE LED 2X4 HIGH BAY WITH CLEAR LENS & WIREGUARD F3E METALUX HBLED-LD5-12SE-W-CL-WG-UNV-L840-CD2-U-EL14W LED 4000 KELVIN 12000 LUMENS 80 CRI -120 109 PENDANT OR SURFACE LED 2X4 HIGH BAY WITH CLEAR LENS & WIREGUARD WITH EMEGENCY BATTERY PACK F4 HALO COMMERCIAL LITHONIA LIGHTOLIER ATLANTIC PRESCOLITE MAXILUME PD610ED015/PDM6A835/61VC LDN6 35/15 LO6AR LSS MVOLT EZ1 P6RD15NZ10UVB W/P6RD835VB W/P6RDCC LED6-DLM15-35K-U-6LED10-SS LF6SL-6LFSL15L35K HH6-LED-1500L-DIM10-MVOLT-MD-35K-90/HH6-6501-CL-WH LED 3500 KELVIN 1500 LUMENS 80 CRI -120 21 RECESSED LED DOWNLIGHT WITH ALZAK TRIM F4E HALO COMMERCIAL LITHONIA LIGHTOLIER ATLANTIC PRESCOLITE MAXILUME PD610ED015IEM/PDM6A835/61VCEM LDN6 35/15 LO6AR LSS MVOLT EZ1 EL P6RD15NZ10UVBEM W/P6RD835VB W/P6RDCC LED6-DLM15-35K-U-ILEM-6LED10-SS LF6SLEM-6LFSL15L35KEM HH6-LED-1500L-DIM10-MVOLT-MD-35K-90-EMG-LED/HH6-6501-CL-WH LED 3500 KELVIN 1500 LUMENS 80 CRI -120 21 RECESSED LED DOWNLIGHT WITH ALZAK TRIM AND EMERGENCY BATTERY PACK F4E HALO COMMERCIAL LITHONIA LIGHTOLIER ATLANTIC PRESCOLITE MAXILUME PD610ED015IEM/PDM6A835/61VCEM LDN6 35/15 LO6AR LSS MVOLT EZ1 EL P6RD15NZ10UVBEM W/P6RD835VB W/P6RDCC LED6-DLM15-35K-U-ILEM-6LED10-SS LF6SLEM-6LFSL15L35KEM HH6-LED-1500L-DIM10-MVOLT-MD-35K-90-EMG-LED/HH6-6501-CL-WH LED 3500 KELVIN 1500 LUMENS 80 CRI -120 21 RECESSED LED DOWNLIGHT WITH ALZAK TRIM AND EMERGENCY BATTERY PACK F5 HALO LITHONIA LIGHTOLIER WESTINGHOUSE PRESCOLITE SATCO SMD6R6835WH FMML-7-8-30-WL S-5-R-8-35K-7 63221 LBS5LEDA6L-30K-9-WH S9331 LED 3500 KELVIN 600 LUMENS 80 CRI -120 14 RECESSED LED DOWNLIGHT SHOWER W/WHITE TRIM F6 TRULY GREEN SOLUTIONS CPMR-0636-40-BK LED 4000 KELVIN 2465 LUMENS 80 CRI -120 25 PENDANT 6" PENDANT WITH 6' CORD TO BE CUT ON JOB SITE Remarks F7 HALO COMMERCIAL HC4-07-D010 LED 3500 KELVIN 700 LUMENS 80 CRI -120 21 RECESSED 4" LED DOWNLIGHT F8 SEABLE GLASS AND HOUSING DECORATIVE PENDANT LED -120 24 PENDANT TO BE SELECTED BY THE ARCHITECT VERIFY SPECIFICATION WITH INTERIORS F9 METALUX LITHONIA DAY-BRITE LSI COLUMBIA ORACLE 4SNLED-LD4-30SL-LW-UNV-L835-CD1-U ZL1N-L48-3000LM-FST-MVOLT-35K-80CRI-WH FSS440L835-UNV-DIM SDL-4-LED-SS-WW-UE LCL4-35LW-EDU 4-OC1-LED-3000L-DIM10-MVOLT-35K-80 LED 3500 KELVIN 3000 LUMENS 80 CRI -120 29 SURFACE WALL 48" LED STRIP F10 HALO COMMERCIAL LITHONIA LIGHTOLIER ATLANTIC PRESCOLITE MAXILUME LD6B10D010/EU6B10208035/6LBSW1LI LDN6 35/10 LW6AR LSS MVOLT EZ1 P6RD10NZ10UVB W/P6RD835VB W/P6RLWCC LED6WW-DLM11-35K-U-6LED80-SS LF6SLWW-6LFSL11L35KWW HH6-LED-1200L-DIM10-MVOLT-MD-35K-90/HH6-6507-CL-WH LED 3500 KELVIN 1000 LUMENS 80 CRI -120 21 RECESSED LED WALLWASHER WITH ALZAK TRIM F11 METALUX LITHONIA DAY-BRITE LSI COLUMBIA ORACLE 2SNLED-LD4-20SL-LW-UNV-L835-CD1-U ZL1N-L24-2500LM-FST-MVOLT-35K-80CRI-WH FSS220L835-UNV-DIM SDL-2-LED-SS-WW-UE LCL2-35ML-EU 2-OC1-LED-2000L-DIM10-MVOLT-35K-80 LED 3500 KELVIN 2000 LUMENS 80 CRI -120 26 SURFACE/CHAIN 24" LED STRIP F11E METALUX LITHONIA DAY-BRITE LSI COLUMBIA ORACLE 2SNLED-LD4-20SL-LW-UNV-EL14W-L835-CD1-U ZL1N-L24-2500LM-FST-MVOLT-35K-80CRI-E7W-WH FSS220L835-UNV-DIM-EMLED SDL-2-LED-SS-WW-UE-EM LCL2-35ML-EU-ELL14 2-OC1-LED-2000L-DIM10-MVOLT-35K-80-O-EMG-LED LED 3500 KELVIN 2000 LUMENS 80 CRI -120 26 SURFACE/CHAIN 24" LED STRIP WITH EMERGENCY BATTERY PACK F12 EUREKA 7470D-5 LED 4000 KELVIN 1841 LUMENS 80+ CRI -120 20.8 PENDANT TO BE SELECTED BY THE ARCHITECT VERIFY SPECIFICATION WITH INTERIORS F13 MLAMBERT EXTERIOR STRING LIGHTS E26 BASE LED LAMPS 2700 KELVIN 80+ CRI -120 160 MOUNTING TO BE SELECTED BY THE ARCHITECT VERIFY SPECIFICATION WITH INTERIORS ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:03/31/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-6.1 ELECTRICAL SCHEDULES PANEL SCHEDULE "P1" VOLTAGE:208 Y/ 120 VOLTS BUS RATING (AMPS):225 REMARKS: MOUNTING:SURFACE PHASE:3 MAIN LUGS ONLY ENCLOSURE:NEMA 1 WIRE:4 MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLE CIRCUIT BREAKER CIRCUIT NAME FEEDER CKT. LOAD LOAD/PHASE (VA)CKT. LOAD FEEDER CIRCUIT NAME CIRCUIT BREAKER No.AMPS POLE MOD.C WIRE GRD DEMAND FACTOR WATTS ØA ØB ØC WATTS DEMAND FACTOR GRD WIRE C MOD.POLE AMPS No. 1 20 1 -IT/FIRE RISER/EXTERIOR RCPT ¾"#12 #12 1.00 720 1,260 540 1.00 #12 #12 ¾"TECHNOLOGY 111 RCPT -1 20 2 3 20 1 -TESTING 109 RCPT ¾"#12 #12 1.00 540 1,080 540 1.00 #12 #12 ¾"CONSULT 108 RCPT -1 20 4 5 20 1 -KIDS 106 RCPT ¾"#12 #12 1.00 540 1,620 1,080 1.00 #12 #12 ¾"103 & 104 RCPT -1 20 6 7 20 1 -RECEPT 105 RCPT ¾"#12 #12 1.00 720 1,620 900 1.00 #12 #12 ¾"ADMIN 107 RCPT -1 20 8 9 20 1 -HALLWAY RCPTS ¾"#12 #12 1.00 1,620 2,160 540 1.00 #12 #12 ¾"STORAGE 110 -1 20 10 11 20 1 - CRAFT ZONE 115 RCPT ¾"#12 #12 1.00 720 1,020 300 1.00 #12 #12 ¾"115 DISP GFCI 1 20 12 13 20 1 -116 RCPTS ¾"#12 #12 1.00 540 840 300 1.00 #12 #12 ¾"116 DISP GFCI 1 20 14 15 20 1 -119 & 121 RCPT ¾"#12 #12 1.00 360 1,080 720 1.00 #12 #12 ¾"SENSORY 120 RCPT -1 20 16 17 20 1 -128 & 130 RCPT ¾"#12 #12 1.00 360 900 540 1.00 #12 #12 ¾"131 & 124 & 123 RCPT -1 20 18 19 20 1 -126 RCPT ¾"#12 #12 1.00 360 900 540 1.00 #12 #12 ¾"125 RCPT -1 20 20 21 20 1 -127 & 129 RCPT ¾"#12 #12 1.00 1,080 2,700 1,620 1.00 #12 #12 ¾"EVENT CNTR 136 & 138 RCPT -1 20 22 23 20 1 -FOOD PREP 139 RCPT ¾"#12 #12 1.00 540 840 300 1.00 #12 #12 ¾"FOOD PREP 139 DISP GFCI 1 20 24 25 20 1 GFCI FOOD PREP 139 REF ¾"#12 #12 1.00 800 2,420 1,620 1.00 #12 #12 ¾"101 & 102 & 137 RCPT -1 20 26 27 20 1 -EVENT I.T. 135 ¾"#12 #12 1.00 540 900 360 1.00 #12 #12 ¾"RESTROOM 132 & 133 RCPT -1 20 28 29 20 1 -OUTDOOR PATIO 140 RCPT ¾"#12 #12 1.00 360 1,440 1,080 1.00 #12 #12 ¾"SPEECH 226 & 228 RCPT -1 20 30 31 20 1 -SPEECH 230, 232 & 234 ¾"#12 #12 1.00 1,620 2,880 1,260 1.00 #12 #12 ¾"HALLWAY 235 RCPT -1 20 32 33 20 1 -SPEECH 231 & 233 RCPT ¾"#12 #12 1.00 900 2,340 1,440 1.00 #12 #12 ¾"SPEECH 227 & 228 RCPT -1 20 34 35 20 1 -SPEECH 225 & 219 RCPT ¾"#12 #12 1.00 1,440 2,880 1,440 1.00 #12 #12 ¾"SPEECH 217 & 215 RCPT -1 20 36 37 20 1 -LOUNGE 201 RCPT ¾"#12 #12 1.00 1,080 2,340 1,260 1.00 #12 #12 ¾"EVENT FAM 202 & 204 RCPT -1 20 38 39 20 1 -218, 216 & 214 RCPT ¾"#12 #12 1.00 1,620 2,520 900 1.00 #12 #12 ¾"222 & 223 RCPT -1 20 40 41 20 1 -221, 222 & 223 RCPT ¾"#12 #12 1.00 1,080 1,440 360 1.00 #12 #12 ¾"RESTROOM 208 & 209 RCPT -1 20 42 43 20 1 -220, 213 & 212 RCPT ¾"#12 #12 1.00 1,260 2,160 900 1.00 #12 #12 ¾"BKR 312 & IT 313 RCPT -1 20 44 45 20 1 -310 & 308 RCPT ¾"#12 #12 1.00 1,080 2,340 1,260 1.00 #12 #12 ¾"306 & 305 RCPT -1 20 46 47 20 1 -OFFICE 307, 309 & 311 RCPT ¾"#12 #12 1.00 1,620 3,060 1,440 1.00 #12 #12 ¾"302, 314, 304 & 316 RCPT -1 20 48 49 20 1 -323, 322 & 331 HALLWAY RCPT ¾"#12 #12 1.00 1,080 1,620 540 1.00 #12 #12 ¾"317, 318 & HALLWAY RCPT -1 20 50 51 20 1 -OFFICE 330, 328 & 326 RCPT ¾"#12 #12 1.00 1,620 2,520 900 1.00 #12 #12 ¾"324, 325 & HALLWAY RCPT -1 20 52 53 20 1 -107 FAX/COPY MACHINE ¾"#12 #12 1.00 800 1,600 800 1.00 #12 #12 ¾"HALLWAY FAX/COPY MACHINE -1 20 54 55 20 1 -ADA DOOR OPENER LOBBY 103 ¾"#12 #12 1.00 1,600 3,200 1,600 1.00 #12 #12 ¾"ADA DOOR OPENER LOBBY 101 -1 20 56 57 20 1 -EVENT CENTER FLOOR RCPTS ¾"#12 #12 1.00 1,080 2,520 1,440 1.00 #12 #12 ¾"1ST FLOOR PAPER TOWEL DISPENSERS -1 20 58 59 20 1 -2ND FLOOR PAPER TOWEL DISPENSERS ¾"#12 #12 1.00 1,260 2,340 1,080 1.00 #12 #12 ¾"3RD FLOOR PAPER TOWEL DISPENSERS -1 20 60 61 20 1 SPARE 1.00 0 1.00 SPARE -1 20 62 63 20 1 -SPARE 1.00 0 1.00 SPARE -1 20 64 65 20 1 -SPARE 1.00 0 1.00 SPARE -1 20 66 67 -SPACE 1.00 0 1.00 SPACE -68 69 -SPACE 1.00 0 1.00 SPACE -70 71 -SPACE 1.00 0 1.00 SPACE -72 NOTES : 1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØA ØB ØC TOTALS INSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.19,240 20,160 17,140 56,540 CONNECTED LOAD (VA) 2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL 157 CONNECTED LOAD (A) ELECTRICAL CODE.0 0 0 0 DEMAND FACTOR ADJUSTMENTS (VA) 3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT 19,240 20,160 17,140 56,540 TOTAL LOAD (VA) LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL 160 168 143 TOTAL LOAD (A) READ: "DANGER: POTENTIAL ARC FLASH HAZARD"168 MAXIMUM LOAD (A) 4.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELS 34%36%30%PHASE BALANCE STATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B 5.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST. PANEL SCHEDULE "P2" VOLTAGE:208 Y/ 120 VOLTS BUS RATING (AMPS):225 REMARKS: MOUNTING:SURFACE PHASE:3 MAIN LUGS ONLY ENCLOSURE:NEMA 1 WIRE:4 MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLE CIRCUIT BREAKER CIRCUIT NAME FEEDER CKT. LOAD LOAD/PHASE (VA)CKT. LOAD FEEDER CIRCUIT NAME CIRCUIT BREAKER No.AMPS POLE MOD.C WIRE GRD DEMAND FACTOR WATTS ØA ØB ØC WATTS DEMAND FACTOR GRD WIRE C MOD.POLE AMPS No. 1 20 1 -I.T. COMMUNICATION BOARD ¾"#12 #12 1.00 360 960 600 1.00 #12 #12 ¾"FACP RED 1 20 2 3 20 1 -CARD ACCESS PANEL ¾"#12 #12 1.00 600 1,200 600 1.00 #12 #12 ¾"NAC 2ND FLR RED 1 20 4 5 20 1 -MEZZANINE 212 RCPT ¾"#12 #12 1.00 900 1,500 600 1.00 #12 #12 ¾"NAC 3RD FLR RED 1 20 6 7 20 1 -STAFF RR 210 RCPT ¾"#12 #12 1.00 180 780 600 1.00 #12 #12 ¾"SPRINKLER BELL RED 1 20 8 9 20 1 -GYM 122 RCPT ¾"#12 #12 1.00 900 1,900 1,000 1.00 #12 #12 ¾"EWC GYM GFCI 1 20 10 11 20 1 GFCI DISPOSAL 120 ¾"#12 #12 1.00 1,656 2,656 1,000 1.00 #12 #12 ¾"EWC PT GFCI 1 20 12 13 20 1 GFCI DISPOSAL 320 ¾"#12 #12 1.00 1,656 2,656 1,000 1.00 #12 #12 ¾"EWC LOBBY 301 GFCI 1 20 14 15 20 1 GFCI BKR 320 DW ¾"#12 #12 1.00 1,200 2,200 1,000 1.00 #12 #12 ¾"EWC LOUNGE 201 GFCI 1 20 16 17 20 1 GFCI SODA DISPENSER ¾"#12 #12 1.00 840 1,840 1,000 1.00 #12 #12 ¾"EWC LEVEL 2 COORIDOR GFCI 1 20 18 19 20 1 -BKR 320 RCPT ¾"#12 #12 1.00 1,440 2,440 1,000 1.00 #12 #12 ¾"EWC LOBBY 102 GFCI 1 20 20 21 20 1 GFCI BKR 320 REF 1 ¾"#12 #12 1.00 1,200 2,280 1,080 1.00 #12 #12 ¾"321, 329, 327 RCPT -1 20 22 23 20 1 GFCI BKR 320 REF 2 ¾"#12 #12 1.00 1,200 1,800 600 1.00 #12 #12 ¾"COPY/PRINT 329 -1 20 24 25 20 1 -PANTRY/STORAGE 319 RCPT ¾"#12 #12 1.00 360 2,016 1,656 1.00 #12 #12 ¾"DISPOSAL BKR 312 GFCI 1 20 26 27 20 1 -COPY/PRINT MILL HALLWAY 235 ¾"#12 #12 1.00 180 1,380 1,200 1.00 #12 #12 ¾"REF BKR 312 GFCI 1 20 28 29 20 1 -COPY/PRINT MILL HALLWAY 235 ¾"#12 #12 1.00 180 1,080 900 1.00 #12 #12 ¾"EXTERIOR RCPTS -1 20 30 31 20 1 -COPY/PRINT MILL HALLWAY 235 ¾"#12 #12 1.00 180 330 150 1.00 #12 #12 ¾"ADA COMM PANEL RED 1 20 32 33 20 1 -I.T. 313 ¾"#12 #12 1.00 360 540 180 1.00 #12 #12 ¾"ELEVATOR PIT RCPT -1 20 34 35 20 1 -ELEVATOR CAB LIGHTING ¾"#12 #12 1.25 600 700 100 1.25 #12 #12 ¾"ELEVATOR PIT LIGHTING -1 20 36 37 30 2 GFCI 116 DRYER ¾"#10 #10 1.00 2,500 2,680 180 1.00 #12 #12 ¾"ELEVATOR TOP OF SHAFT RCPT -1 20 38 39 -----#10 -1.00 2,500 2,600 100 1.25 #12 #12 ¾"ELEVATOR TOP OF SHAFT LIGHTING -1 20 40 41 20 1 -116 WASHER ¾"#12 #12 1.00 1,200 1,800 600 1.00 #12 #12 ¾"FIRE/SMOKE DOORS & DAMPERS RED 1 20 42 43 20 1 -SUMP PUMP SP-1 ¾"#12 #12 1.00 1,200 6,192 4,992 1.00 #10 #6 1"SWIM SPA GFCI 2 60 44 45 20 1 -SPARE 1.00 4,992 4,992 1.00 -#6 --GFCI --46 47 -SPACE 1.00 0 1.00 SPARE -1 20 48 49 -SPACE 1.00 0 1.00 SPARE -1 20 50 51 -SPACE 1.00 0 1.00 SPACE -52 53 -SPACE 1.00 0 1.00 SPACE -54 NOTES : 1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØA ØB ØC TOTALS INSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.18,054 17,092 11,376 46,522 CONNECTED LOAD (VA) 2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL 129 CONNECTED LOAD (A) ELECTRICAL CODE.0 25 175 200 DEMAND FACTOR ADJUSTMENTS (VA) 3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT 18,054 17,117 11,551 46,722 TOTAL LOAD (VA) LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL 150 143 96 TOTAL LOAD (A) READ: "DANGER: POTENTIAL ARC FLASH HAZARD"150 MAXIMUM LOAD (A) 4.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELS 39%37%25%PHASE BALANCE STATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B 5.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST. SITE LIGHTING FIXTURE SCHEDULE FIXT FIXTURE LAMPS POLE REMARKS#MANUFACTURER CATALOG #VOLTS #/POLE WATTS MOUNTING TYPE QTY/FIXT.MANUFACTURER HEIGHT CATALOG # SF1 MCGRAW EDISON GALN-SA1C-740-U-5MQ 120 1 59 POLE LED 1 LITHONIA GARDCO MCGRAW SPAULDING LTG CMT UNITED LSI 25'-0" SSS 25 4C SSS-25-4-11 SSS-4A25-SFXXX SSS-25-40-1-**-SCBA ZA25-4-0-HS-PC-BC RPSQ-25-4-11 4SQBX-S7G-25-X-4BC F14E RIG-A-LITE MHDA-11-L2-4-U-EM LED 4000 KELVIN 11223 LUMENS 82 CRI -120 80 MOUNTING ELEVATOR SHAFT LIGHT F15 BEGA 66 519 LED 4000 KELVIN 2465 LUMENS 80 CRI -120 25 WALL UP/DOWN WALL SCONCE Remarks F16 ORACLE OWP-FC-211-LED-O-EMG-LED LED 4000 KELVIN 3323 LUMENS 80 CRI -120 21 WALL EMERGENCY WALL PACK Remarks F17 METALUX LITHONIA LA LIGHTING XTRALIGHT COLUMBIA ORACLE 4SWLED-LD4-40SL-LW-UNV-L835-CD1-SVPD2-U WL4-40L-EZ1-LP835-NESPDT7-DIM10 3-WSE201-4K-4L-1DRDM-UNV-1/835 LST-LED-4-02-042-X-T-X-DIM-XX-RL-U-X-W-MLD LBIL4-35ML-EDU 4-OW1B-LED-4000L-DIM10-MVOLT-35K-80-MS-FM105 LED 3500 KELVIN 4000 LUMENS 80 CRI -120 53 SURFACE WALL 48" STAIRWELL LED WITH INTEGRAL OCCUPANCY SENSOR F18 TRULY GREEN SOLUTIONS CPMR-0418-40-BK LED 4000 KELVIN 2465 LUMENS 80 CRI -120 25 PENDANT 4" PENDANT Remarks F19 Q-TRAN SW24/1.5-DMP-40-CON24-CON24-XX LED 4000 KELVIN 178 LUMENS/FT 90+CRI -24 1.5W/FT SURFACE LED STRIP LIGHT WITH EXTRUSION EXTERIOR USE F20 PACE EUDC-II-UD-900-8-16W-120-277UNV LED 4000 KELVIN 2265 LUMENS 80 CRI -120 16 SURFACE LED UP/DOWN CYLINDER FINISH TO BE SELECTED BY ARCHITECT F21 OXYGEN 3-5012-XX LED 1500 LUMENS 3000 KELVIN 90 CRI -120 23 SURFACE LED VANITY LIGHT FINISH TO BE SELECTED BY ARCHITECT F22 PRUDENTIAL RDP-4-LED4-LO-NU-BK-SC-UNV-STC48-BK-X3-ND LED 325 LUMENS 4000 KELVIN 90 CRI -120 5.2 PENDANT LED PENDANT LIGHT OVER RECEPTION F23 CDS LIGHTING EXPOSE-P-BK-BK-USV E27/E26 LED LAMP 18 120 12 PENDANT CORD AND SOCKET. DECORATIVE LAMPS TO BE SELECTED BY OWNER EG1 SURELITE LITHONIA PROLITE LSI DUAL-LITE MAXILUME SELW25XX AFN-DB-EXT DBEL-ACEM-W-SDT-CW CSN-DB-CT PGZ-HTR ELM-807-BZ 6W XENON INCLUDED 2 120 12 SURFACE WALL EMERGENCY EGRESS LIGHT FINISH TO BE SELECTED BY ARCHITECT EM1 SURELITE LITHONIA LIGHTOLIER LSI DUAL-LITE MAXILUME SEL17 ELM2 E611W LTEM-WH EZ-2 ELM-LED-861 INCLUDED 2 120 5.4 SURFACE WALL 2-HEAD EM WALL PACK (SURFACE) EX1 SURELITE LITHONIA CHLORIDE LSI DUAL-LITE MAXILUME APX7G LQM-S-W-3-G-EL-N ER55L3WG EX-G-U-WB-WH EVEUGWE ELX-603-G-W INCLUDED 2 120 1.5 UNIVERSAL UNIVERSAL MOUNT WITH EXTRA FACE PLATE FOR FIELD CONVERSION 1-2 FACE NICKEL/CADMIUM BATTERY SINGLE FACE EXIT EX2 SURELITES LITHONIA LIGHTOLIER LSI MAXILUME LPX-70-DGWHDH LHQM-S-1-G-EL-N LC18NH71GW LPRX-G-U-WH-LD11 ELX-703-G-W INCLUDED 2 120 5.4 SURFACE WALL 2-HEAD EM WALL PACK (SURFACE) WITH EXIT LIGHT LIGHT FIXTURE SCHEDULE FIXTURE NUMBER FIXTURE MANUFACTURER FIXTURE CATALOG # LAMPS FIXTURE DESCRIPTION REMARKS TYPE QTY.VOLTS WATTS MOUNTING ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:04/21/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-6.2 04/21/20231 ADDENDUM 1 ELECTRICAL SCHEDULES PANEL SCHEDULE "LP" VOLTAGE:208 Y/ 120 VOLTS BUS RATING (AMPS):225 REMARKS: MOUNTING:SURFACE PHASE:3 MAIN LUGS ONLY ENCLOSURE:NEMA 1 WIRE:4 MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLE CIRCUIT BREAKER CIRCUIT NAME FEEDER CKT. LOAD LOAD/PHASE (VA)CKT. LOAD FEEDER CIRCUIT NAME CIRCUIT BREAKER No.AMPS POLE MOD.C WIRE GRD DEMAND FACTOR WATTS ØA ØB ØC WATTS DEMAND FACTOR GRD WIRE C MOD.POLE AMPS No. 1 20 1 -EVENT CENTER LTG ¾"#12 #12 1.25 1,066 1,432 365 1.25 #12 #12 ¾"RM 137,138,139 & 140 LTG -1 20 2 3 20 1 -RM 101,102,134,135 & ENTRANCE LTG ¾"#12 #12 1.25 863 3,697 2,834 1.25 #10 #10 ¾"GYM 122 LTG -1 30 4 5 20 1 -RESTROOM 131,132 & 133 LTG ¾"#12 #12 1.25 468 1,109 641 1.25 #12 #12 ¾"RM 103,104 & 105 LTG -1 20 6 7 20 1 -FIRST FLOOR HALLWAY LTG ¾"#12 #12 1.25 1,113 1,870 757 1.25 #12 #12 ¾"RM 106,107,108,109,110,111,112,113,114 LTG -1 20 8 9 20 1 -RM 115,116,117,118,119 LTG ¾"#12 #12 1.25 1,338 2,384 1,046 1.25 #12 #12 ¾"RM 120,121,123,124,125,126,127,128,129 LTG -1 20 10 11 20 1 -RM 211,213, GYM & MEZZANINE LTG ¾"#12 #12 1.25 1,022 2,760 1,738 1.25 #12 #12 ¾"2ND FLOOR HALLWAY & RM 220 LTG -1 20 12 13 20 1 -RM 221,222,223,224,219,225,227,217,215 LTG ¾"#12 #12 1.25 815 1,464 650 1.25 #12 #12 ¾"RM 226,228,229,230,231,232,233,234 LTG -1 20 14 15 20 1 -RM 218,216,214,207,208,209,210 LTG ¾"#12 #12 1.25 646 1,483 837 1.25 #12 #12 ¾"RM 201,202,203,204,205,206,215,315 LTG -1 20 16 17 20 1 -HALLWAY 317,316,318,301,302,314,319 LTG ¾"#12 #12 1.25 1,800 3,079 1,280 1.25 #12 #12 ¾"RM 303,304,305,306,307,308,309,310,311,312 LTG -1 20 18 19 30 1 -RM 329,327,320,324,326,328,330 LTG ¾"#10 #10 1.25 2,061 3,279 1,218 1.25 #12 #12 ¾"RM 312,310,308,303,311,309,307,304,305,306 LTG -1 20 20 21 20 1 -EXTERIOR BUILDING MNTD LTG ¾"#12 #12 1.25 1,578 1,650 72 1.25 #12 #12 ¾"EXTERIOR BENCH LIGHTING -1 20 22 23 20 1 -PARKING LOT POLE LTG ¾"#12 #12 1.25 295 1,295 1,000 1.25 #12 #12 ¾"SIGN LIGHTING -1 20 24 25 -SPACE 1.25 0 1.25 SPACE -26 27 -SPACE 1.25 0 1.25 SPACE -28 29 -SPACE 1.25 0 1.25 SPACE -30 31 -SPACE 1.25 0 1.25 SPACE -32 33 -SPACE 1.25 0 1.25 SPACE -34 35 -SPACE 1.25 0 1.25 SPACE -36 37 -SPACE 1.25 0 1.25 SPACE -38 39 -SPACE 1.25 0 1.25 SPACE -40 41 -SPACE 1.25 0 1.25 SPACE -42 NOTES : 1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØA ØB ØC TOTALS INSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.8,045 9,213 8,243 25,501 CONNECTED LOAD (VA) 2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL 71 CONNECTED LOAD (A) ELECTRICAL CODE.2,011 2,303 2,061 6,375 DEMAND FACTOR ADJUSTMENTS (VA) 3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT 10,056 11,517 10,304 31,877 TOTAL LOAD (VA) LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL 84 96 86 TOTAL LOAD (A) READ: "DANGER: POTENTIAL ARC FLASH HAZARD"96 MAXIMUM LOAD (A) 4.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELS 32%36%32%PHASE BALANCE STATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B 5.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST. PANEL SCHEDULE "KP" VOLTAGE:208 Y/ 120 VOLTS BUS RATING (AMPS):100 REMARKS: MOUNTING:FLUSH PHASE:3 MAIN LUGS ONLY ENCLOSURE:NEMA 1 WIRE:4 MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLE CIRCUIT BREAKER CIRCUIT NAME FEEDER CKT. LOAD LOAD/PHASE (VA)CKT. LOAD FEEDER CIRCUIT NAME CIRCUIT BREAKER No.AMPS POLE MOD.C WIRE GRD DEMAND FACTOR WATTS ØA ØB ØC WATTS DEMAND FACTOR GRD WIRE C MOD.POLE AMPS No. 1 20 1 GFCI FRIDGE ¾"#12 #12 1.00 800 1,600 800 1.00 #12 #12 ¾"FRIDGE GFCI 1 20 2 3 40 2 GFCI DOUBLE OVEN ¾"#8 #10 1.00 3,144 3,894 750 1.00 #12 #12 ¾"DISPOSAL GFCI 1 20 4 5 -----#8 -1.00 3,144 4,544 1,400 1.00 #12 #12 ¾"RANGE GFCI 2 20 6 7 50 2 GFCI RANGE ¾"#8 #10 1.00 4,000 5,400 1,400 1.00 -#12 -----8 9 -----#8 -1.00 4,000 4,720 720 1.00 #12 #12 ¾"COUNTER RCPT GFCI 1 20 10 11 20 1 GFCI COUNTER RCPT ¾"#12 #12 1.00 720 1,470 750 1.00 #12 #12 ¾"DISPOSAL GFCI 1 20 12 13 20 -SPARE 1.00 720 720 1.00 #12 #12 ¾"COUNTER RCPT GFCI 1 20 14 15 20 1 -SPARE 1.00 720 720 1.00 #12 #12 ¾"COUNTER RCPT GFCI 1 20 16 17 20 1 -SPARE 1.00 0 1.00 SPARE -1 20 18 19 20 1 -SPARE 1.00 0 1.00 SPARE -1 20 20 21 20 1 -SPARE 1.00 0 1.00 SPARE -1 20 22 23 -SPACE 1.00 0 1.00 SPACE -24 25 -SPACE 1.00 0 1.00 SPACE -26 27 -SPACE 1.00 0 1.00 SPACE -28 29 -SPACE 1.00 0 1.00 SPACE -30 31 -SPACE 1.00 0 1.00 SPACE -32 33 -SPACE 1.00 0 1.00 SPACE -34 35 -SPACE 1.00 0 1.00 SPACE -36 37 -SPACE 1.00 0 1.00 SPACE -38 39 -SPACE 1.00 0 1.00 SPACE -40 41 -SPACE 1.00 0 1.00 SPACE -42 NOTES : 1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØA ØB ØC TOTALS INSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.7,720 9,334 6,014 23,068 CONNECTED LOAD (VA) 2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL 64 CONNECTED LOAD (A) ELECTRICAL CODE.0 0 0 0 DEMAND FACTOR ADJUSTMENTS (VA) 3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT 7,720 9,334 6,014 23,068 TOTAL LOAD (VA) LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL 64 78 50 TOTAL LOAD (A) READ: "DANGER: POTENTIAL ARC FLASH HAZARD"78 MAXIMUM LOAD (A) 4.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELS 33%40%26%PHASE BALANCE STATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B 5.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST. PANEL SCHEDULE "MP" VOLTAGE:208 Y/ 120 VOLTS BUS RATING (AMPS):600 REMARKS: MOUNTING:SURFACE PHASE:3 MAIN LUGS ONLY ENCLOSURE:NEMA 1 WIRE:4 MINIMUM EQUIPMENT RATING:SEE FAULT CURRENT TABLE CIRCUIT BREAKER CIRCUIT NAME FEEDER CKT. LOAD LOAD/PHASE (VA)CKT. LOAD FEEDER CIRCUIT NAME CIRCUIT BREAKER No.AMPS POLE MOD.C WIRE GRD DEMAND FACTOR WATTS ØA ØB ØC WATTS DEMAND FACTOR GRD WIRE C MOD.POLE AMPS No. 1 100 3 -ERV-1 1¼"#3 #8 1.00 8,947 13,330 4,383 1.00 #10 #8 ¾"ODU-1 -3 40 2 3 -----#3 -1.00 8,947 13,330 4,383 1.00 -#8 -----4 5 -----#3 -1.00 8,947 13,330 4,383 1.00 -#8 -----6 7 20 2 -SCU-1 ¾"#12 #12 1.00 1,373 5,756 4,383 1.00 #10 #8 ¾"ODU-2 -3 40 8 9 -----#12 -1.00 1,373 5,756 4,383 1.00 -#8 -----10 11 20 2 -SCU-1 ¾"#12 #12 1.00 1,373 5,756 4,383 1.00 -#8 -----12 13 -----#12 -1.00 1,373 5,756 4,383 1.00 #10 #8 ¾"ODU-3 -3 40 14 15 20 1 -EQUIPMENT RCPT ROOF ¾"#12 #12 1.00 360 4,743 4,383 1.00 -#8 -----16 17 20 1 GFEP HEAT TRACE ROOF DRAINS ¾"#12 #12 1.00 1,000 5,383 4,383 1.00 -#8 -----18 19 20 1 GFEP HEAT TRACE ROOF DRAINS ¾"#12 #12 1.00 1,000 4,843 3,843 1.00 #10 #8 ¾"RTU-5 EVENT CENTER -3 50 20 21 20 2 -EWH-1 ROOF STAIR ¾"#12 #12 1.00 749 4,592 3,843 1.00 -#8 -----22 23 -----#12 -1.00 749 4,592 3,843 1.00 -#8 -----24 25 20 2 -EWH-1 STAIR 315 ¾"#12 #12 1.00 749 4,592 3,843 1.00 #10 #8 ¾"RTU-5 EVENT CENTER -3 50 26 27 -----#12 -1.00 749 4,592 3,843 1.00 -#8 -----28 29 20 2 -EWH-1 STAIR 206 ¾"#12 #12 1.00 749 4,592 3,843 1.00 -#8 -----30 31 -----#12 -1.00 749 4,592 3,843 1.00 #10 #8 ¾"RTU-5 GYM -3 50 32 33 20 2 -EWH-1 STAIR 332 ¾"#12 #12 1.00 749 4,592 3,843 1.00 -#8 -----34 35 -----#12 -1.00 749 4,592 3,843 1.00 -#8 -----36 37 20 2 -EWH-1 STAIR 224 ¾"#12 #12 1.00 749 4,592 3,843 1.00 #10 #8 ¾"RTU-5 GYM -3 50 38 39 -----#12 -1.00 749 4,592 3,843 1.00 -#8 -----40 41 20 2 -EWH-1 STAIR 114 ¾"#12 #12 1.00 749 4,592 3,843 1.00 -#8 -----42 43 -----#12 -1.00 749 1,109 360 1.00 #12 #12 ¾"WH-1 & CP-1 LEVEL 1 -1 20 44 45 20 2 -SCU-1 ¾"#12 #12 1.00 1,373 1,733 360 1.00 #12 #12 ¾"WH-2 & CP-1 LEVEL 2 -1 20 46 47 -----#12 -1.00 1,373 1,733 360 1.00 #12 #12 ¾"WH-2 & CP-1 LEVEL 3 -1 20 48 49 20 2 -EWH-1 FIRE RISER 112 ¾"#12 #12 1.00 749 949 200 1.00 #12 #12 ¾"UNIT HEATERS UH-1 -1 20 50 51 -----#12 -1.00 749 1,349 600 1.00 #12 #12 ¾"FIRE PLACE LOUNGE 201 -1 20 52 53 20 2 -EWH-2 RECPT 105 ¾"#12 #12 1.00 562 1,144 582 1.00 #12 #12 ¾"BS-2,FC-1.3,FC-2,FC-1 -2 15 54 55 -----#12 -1.00 562 1,144 582 1.00 -#12 -----56 57 20 2 -EWH-1 VESTIBULE 103 ¾"#12 #12 1.00 749 1,820 1,071 1.00 #12 #12 ¾"FC-1.3,(2)FC-2.5,FC-4 -2 15 58 59 -----#12 -1.00 749 1,820 1,071 1.00 -#12 -----60 61 20 2 -EWH-1 VESTIBULE 101 ¾"#12 #12 1.00 749 1,498 749 1.00 #12 #12 ¾"BS-1,FC-1.3,FC-1.5,FC-4 -2 15 62 63 -----#12 -1.00 749 1,498 749 1.00 -#12 -----64 65 20 1 GFEP HEAT TRACE ROOF DRAINS ¾"#12 #12 1.00 1,000 1,499 499 1.00 #12 #12 ¾"FC-2,FC-.08,FC-.06 -2 15 66 67 20 1 GFEP HEAT TRACE ROOF DRAINS ¾"#12 #12 1.00 1,000 1,499 499 1.00 -#12 -----68 69 20 1 GFEP HEAT TRACE ROOF DRAINS ¾"#12 #12 1.00 500 1,176 676 1.00 #12 #12 ¾"BS-3,FC-2,FC-0.8,FC-3,FC-1.5 -2 15 70 71 -SPACE 1.00 676 676 1.00 -#12 -----72 73 -SPACE 1.00 759 759 1.00 #12 #12 ¾"FC-0.6,FC-4,FC-2,FC-3 -2 15 74 75 -SPACE 1.00 759 759 1.00 -#12 -----76 77 -SPACE 1.00 0 1.00 SPACE -78 79 -SPACE 1.00 0 1.00 SPACE -80 81 -SPACE 1.00 0 1.00 SPACE -82 83 -SPACE 1.00 0 1.00 SPACE -84 NOTES : 1.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE.ØA ØB ØC TOTALS INSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW.50,417 50,530 49,708 150,655 CONNECTED LOAD (VA) 2.LOAD DEMANDS CALCULATED AS PER SECTIONS 210 & 220 OF THE NATIONAL 418 CONNECTED LOAD (A) ELECTRICAL CODE.0 0 0 0 DEMAND FACTOR ADJUSTMENTS (VA) 3.PANEL COVER SHALL BE FIELD MARKED FOR FLASH PROTECTION WITH A PERMANENT 50,417 50,530 49,708 150,655 TOTAL LOAD (VA) LABEL AS REQUIRED BY THE NATIONAL ELECTRICAL CODE SECTION 110. LABEL SHALL 420 421 414 TOTAL LOAD (A) READ: "DANGER: POTENTIAL ARC FLASH HAZARD"421 MAXIMUM LOAD (A) 4.FIRE ALARM SYSTEMS SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELS 33%34%33%PHASE BALANCE STATING “FIRE ALARM CIRCUIT” AS REQUIRED BY THE NATIONAL ELECTRICAL CODE ARTICLE 760.41B 5.ABBREVIATIONS: CO-CONVENIENCE OUTLET, RR-RESTROOM, (N)ORTH, (S)OUTH, (E)AST, (W)EST. LOAD CALCULATIONS GROSS BUILDING AREA:37,040 SQ. FT BUILDING VOLTAGE:208 VOLTS PHASE 3 PHASE OCCUPANCY TYPE:BUSINESS GENERAL LOADS: LIGHTING LOAD W/ 125% DEMAND: 33,520 VA RECEPTACLE LOAD: 85,898 VA FIRST 10,000 VA @ 100% 10,000 VA REMAINDER @50% 37,949 VA ADJUSTED RECEPTACLE TOTAL LOAD: 47,949 VA SMALL APPLIANCE LOAD: 6,200 VA KITCHEN EQUIPMENT 18,688 VA MISC: 4,950 VA TOTAL LOAD: 29,838 VA HVAC LOADS: COOLING/HEATING 130,364 VA RESISTANCE HEATING: 19,902 VA EXHAUST: -VA WATER HEATING: 240 VA TOTAL: 150,505 VA EQUIPMENT LOADS: MACHINERY: -VA ELEVATOR: 22,517 VA PUMPS: -VA WELDERS: -VA AIR COMPRESSORS: 26,840 VA MOTORS -VA NET COMPUTED LOAD 311,169 VA NET COMPUTED LOAD (VA ¸ VOLTS ):864 AMPS FAULT CURRENT CALCULATION TABLE MAIN UTILITY COMPANY TRANSFORMER TRANSFORMER KVA AFC AT UTILITY %Z 3Ø 120/208V -1200A PAD MOUNTED 500 65,000 A 1.24% CONFIGURATION FEEDER SYSTEM FAULT CURRENT AT EQUIPMENT FULL OR SERIES RATED MINIMUM SYMMETRICAL EQUIPMENT AIC RATING FROM TO LENGTH SOURCE FAULT CURRENT FEEDER SIZE FEEDER S PER PHASE WIRE CONSTANT LINE TO LINE VOLTS XFMR SECONDAR Y VOLTS PHASE KVA %Z MOTOR LOAD TRANSFORMER UTILITY SWITCHBOARD SES 40'-0''65,000 AIC 350 AL 5 16,812 208 V 3Ø -51,687 AIC FULL 65,000 AIC SWITCHBOARD SES PANELBOARD LP 80'-0''51,687 AIC 1 AL 1 4,678 208 V 3Ø -6,182 AIC FULL 10,000 AIC SWITCHBOARD SES PANELBOARD P1 80'-0''51,687 AIC 250 AL 1 12,862 208 V 3Ø -14,057 AIC FULL 22,000 AIC SWITCHBOARD SES PANELBOARD P2 80'-0''51,687 AIC 3/0 AL 1 9,110 208 V 3Ø -10,814 AIC FULL 22,000 AIC SWITCHBOARD SES PANELBOARD KP 70'-0''51,687 AIC 1 AL 1 4,678 208 V 3Ø -6,947 AIC FULL 10,000 AIC SWITCHBOARD SES PANELBOARD MP 120'-0''51,687 AIC 500 AL 2 21,390 208 V 3Ø -23,416 AIC FULL 42,000 AIC SWITCHBOARD SES ELEVATOR DISC 115'-0''51,687 AIC 3 CU 1 4,802 208 V 3Ø -4,571 AIC FULL 10,000 AIC NOTE: DISTANCES INDICATED ARE FOR FAULT-CURRENT ANALYSIS ONLY. CONTRACTOR SHALL USE FIELD MEASUREMENTS ESTABLISH CONDUCTOR LENGTHS FOR ORDERING PURPOSES. ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:05/23/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-6.3 04/21/20231 ADDENDUM 1 05/01/20232 CITY COMMENTS 3 05/08/2023 REVISION 4 05/23/2023 CITY COMMENTS 2 ELECTRICAL SCHEDULES ELECTRICAL SPECIFICATIONS GENERAL PROVISION A.REFERENCE 1.THE GENERAL CONDITIONS AND OTHER CONTRACT DRAWINGS AS SET FORTH IN THE FOREGOING PAGES ARE HEREBY INCORPORATED INTO AND BECOME A PART OF THE SPECIFICATIONS FOR WORK UNDER THIS TITLE, INSOFAR AS THEY APPLY HERETO. 2.ALL SPECIFICATIONS UNDER THIS DIVISION TITLE ARE DIRECTED TO AND ARE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR, UNLESS OTHER TRADES OR PERSONS ARE SPECIFICALLY MENTIONED, “ELECTRICAL CONTRACTOR” IS INFERRED AND INTENDED. B.CONTRACT DRAWINGS 1.THE DRAWINGS ACCOMPANYING THESE SPECIFICATIONS ARE COMPLEMENTARY EACH TO THE OTHER AND WHAT IS CALLED FOR BY ONE SHALL BE AS IF CALLED FOR BY BOTH. 2.CONSULT ALL CONTRACT DRAWINGS WHICH MAY AFFECT THE LOCATION OF EQUIPMENT, CONDUIT AND WIRING AND MAKE MINOR ADJUSTMENTS IN LOCATION TO SECURE COORDINATION. 3.WIRING LAYOUT IS SCHEMATIC AND EXACT LOCATIONS SHALL BE DETERMINED BY FIELD CONDITIONS. 4.OTHER THAN MINOR ADJUSTMENTS SHALL BE SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR APPROVAL BEFORE PROCEEDING WITH THE WORK. C.JOB-SITE COPY OF DOCUMENTS 1.MAINTAIN AT THE SITE, ONE COPY OF ALL DRAWINGS, SPECIFICATIONS, ADDENDA APPROVED SHOP DRAWINGS, CHANGE ORDERS AND OTHER MODIFICATIONS, IN GOOD ORDER AND MARKED TO RECORD ALL CHANGES MADE DURING CONSTRUCTION. THESE SHALL BE AVAILABLE TO THE OWNER'S REPRESENTATIVE. THE DRAWINGS MARKED TO RECORD ALL CHANGES MADE DURING CONSTRUCTION SHALL BE DELIVERED TO THE OWNER'S REPRESENTATIVE FOR THE OWNER UPON COMPLETION OF THE WORK. AN ADDITIONAL SET OF DRAWINGS WILL BE FURNISHED BY THE OWNER'S REPRESENTATIVE FOR THIS PURPOSE UPON REQUEST. D.MANUFACTURER'S DRAWINGS 1.THE CONTRACTOR SHALL SUBMIT TO THE ARCHITECT FOR REVIEW. (6) COPIES OF MANUFACTURER'S DRAWINGS AND WIRING DIAGRAMS. THE ENGINEER WILL REVIEW CONTRACTOR'S SHOP DRAWINGS AND RELATED SUBMITTALS (AS INDICATED BELOW) WITH RESPECT TO THE ABILITY OF THE DETAILED WORK, WHEN COMPLETE, TO BE A PROPERLY FUNCTIONING INTEGRAL ELEMENT OF THE OVERALL SYSTEM DESIGNED BY THE ENGINEER. BEFORE SUBMITTING A SHOP DRAWING OR ANY RELATED MATERIAL TO THE ENGINEER, CONTRACTOR SHALL: REVIEW EACH SUCH SUBMISSION FOR CONFORMANCE WITH THE MEANS, METHODS, TECHNIQUES, SEQUENCES,AND OPERATIONS OF CONSTRUCTION, AND SAFETY PRECAUTIONS AND PROGRAMS INCIDENTAL THERETO, ALL OF WHICH ARE THE SOLE RESPONSIBILITY OF CONTRACTOR: APPROVE EACH SUCH SUBMISSION BEFORE SUBMITTING IT; AND SO STAMP EACH SUCH SUBMISSION BEFORE SUBMITTING IT. THE ENGINEER SHALL ASSUME THAT NO SHOP DRAWING OR RELATED SUBMITTAL COMPRISES A VARIATION UNLESS CONTRACTOR ADVISES ENGINEER OTHERWISE VIA A WRITTEN INSTRUMENT WHICH IS ACKNOWLEDGED BY ENGINEER IN WRITING. THE ITEMS, TYPES OF SUBMITTALS AND RELATED MATERIAL (IF ANY) CALLED FOR ARE INDICATED BELOW: ITEMS TYPE SUBMITTALS REQUESTED LIGHTING AND POWER PANELS SHOP DRAWINGS LIGHTING FIXTURES CATALOG CUTS E.GUARANTEES 1.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEFECTS, REPAIRS AND REPLACEMENTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR AFTER DATE OF SUBSTANTIAL COMPLETION AS DETERMINED BY THE OWNER'S REPRESENTATIVE. PRODUCT GUARANTEES GREATER THAN ONE (1) YEAR SHALL BE PASSED ALONG TO THE OWNER FOR FULL BENEFIT OF THE MANUFACTURER'S WARRANTY. WORK INCLUDED A.INSTALLATION, MATERIALS, AND WORKMANSHIP 1.FURNISH AND INSTALL ALL NECESSARY ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS AND OTHER SIMILAR APPURTENANCES NOT INDICATED ON THE DRAWINGS BUT WHICH ARE REQUIRED FOR A COMPLETE AND PROPERLY INSTALLED SYSTEM CONSISTENT WITH THE ARCHITECTURAL TREATMENT OF THE BUILDING. 2.THE ELECTRICAL CONTRACTOR, INSOFAR AS THE WORK IS CONCERNED, SHALL AT ALL TIMES KEEP THE PREMISES IN A NEAT AND ORDERLY CONDITION. AND AT THE COMPLETION OF THE WORK, SHALL PROPERLY CLEAN UP AND CART AWAY DEBRIS AND EXCESS MATERIALS. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COST OF DUMPSTER & REFUSED DISPOSAL AS REQUIRED FOR ELECTRICAL WORK. 3.ALL MATERIALS SHALL BE NEW AND UNDETERIORATED AND OF A QUALITY NOT LESS THAN THE MINIMUM SPECIFIED. B.COORDINATION OF PLANS AND SPECIFICATIONS 1.CONTACT THE OWNER'S REPRESENTATIVE IMMEDIATELY IF THERE IS ANY QUESTIONS REGARDING THE MEANING OR INTENT OF EITHER PLANS OR SPECIFICATIONS, OR UPON NOTICING ANY DISCREPANCIES OR OMISSIONS IN EITHER PLANS OR SPECIFICATIONS. C.CUTTING AND PATCHING 1.ALL ELECTRICAL EQUIPMENT SHALL BE KEPT DRY AND CLEAN DURING THE CONSTRUCTION PERIOD. INTERIOR OF ALL ENCLOSURES SHALL BE CLEANED OF DIRT AND DEBRIS BEFORE INSTALLING TRIM OR COVERS. 2.ALL FINISHED SURFACES OF EQUIPMENT FURNISHED UNDER THIS CONTRACT SHALL BE THOROUGHLY CLEANED OF DIRT AND ALL SCRATCHED OR DAMAGED SURFACES SHALL BE TOUCHED UP WITH MATCHING MATERIALS BEFORE FINAL ACCEPTANCE OF THE WORK. 3.WHEN ALL WORK IS COMPLETED AND ALL WORK HAS BEEN SATISFACTORILY TESTED AND ACCEPTED BY THE OWNER'S REPRESENTATIVE, ALL CONDUIT AND OTHER EXPOSED SURFACES SHALL BE THOROUGHLY CLEANED. CODES AND FEES A.CODES: 1.ALL WORK PERFORMED UNDER THIS SPECIFICATION SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AS PREPARED AND PUBLISHED BY THE NATIONAL FIRE PROTECTION ASSOCIATION AND ANY APPLICABLE STATE OR LOCAL CODES. B.FEES: 1.OBTAIN AND PAY FOR ANY AND ALL PERMITS REQUIRED BY ALL LAWS AND REGULATIONS AND PUBLIC AUTHORITY HAVING SUCH JURISDICTION. TESTS AND INSPECTIONS A.OBTAIN ALL INSPECTIONS REQUIRED BY ALL LAWS, ORDINANCES, RULES, REGULATIONS OR PUBLIC AUTHORITY HAVING JURISDICTION AND OBTAIN CERTIFICATES OF SUCH INSPECTIONS AND SUBMIT SAME TO THE OWNER'S REPRESENTATIVE. PAY ALL FEES, CHARGES AND OTHER EXPENSES IN CONNECTION THEREIN. OBTAIN OCCUPANCY PERMIT AS REQUIRED BY OWNER. FINAL PAYMENT SHALL NOT BE MADE UNTIL OCCUPANCY PERMIT IS OBTAINED. B.WORK SHALL BE UNACCEPTABLE WHEN FOUND TO BE DEFECTIVE OR CONTRARY TO THE PLANS SPECIFICATIONS, CODES SPECIFIED OR ACCEPTED STANDARDS OF GOOD WORKMANSHIP. C.THE CONTRACTOR SHALL PROMPTLY CORRECT ALL WORK FOUND UNACCEPTABLE BY THE OWNER'S REPRESENTATIVE WHETHER OBSERVED BEFORE OR AFTER SUBSTANTIAL COMPLETION AND WHETHER OR NOT FABRICATED, INSTALLED OR COMPLETED. THE CONTRACTOR SHALL BEAR ALL COSTS OF CORRECTING SUCH UNACCEPTABLE WORK, INCLUDING COMPENSATION FOR THE OWNERS REPRESENTATIVE ADDITIONAL SERVICES MADE NECESSARY THEREBY. CONDUIT A.FURNISH AND INSTALL ALL CONDUITS, BOXES, FITTINGS, ETC., FOR A COMPLETE RACEWAY SYSTEM. B.ALL WIRING SHALL BE RUN IN EMT CONDUIT OR MC CABLE WITH GROUND CONDUCTOR UNLESS OTHERWISE NOTED. C.ALL CONDUIT SIZES STATED HEREIN OR MARKED ON THE DRAWINGS ARE MINIMUM SIZE AND SHALL BE NO LESS THAN 12" UNLESS OTHERWISE NOTED. D.ALL CONDUIT SHALL BE SUBSTANTIALLY SUPPORTED BY PIPE STRAPS OR SUITABLE CLAMPS OR HANGERS ATTACHED TO THE ELEMENTS OF THE BUILDING STRUCTURE TO PROVIDE RIGID INSTALLATION; IN NO CASE SHALL CONDUIT BE ATTACHED OR SUPPORTED FROM ADJOINING PIPE OR INSTALLED IN SUCH A MANNER AS TO PREVENT THE READY REMOVAL OF OTHER PIPE FOR REPAIRS. WIRE AND CABLE A.ALL CONDUCTORS SHALL BE COPPER AND OF THE AWG SIZE AND TYPE SHOWN ON THE DRAWINGS. WHERE NO SIZE OR TYPE IS SHOWN. CONDUCTORS SHALL NOT BE LESS THAN #12 TYPE XHHW, THHN, OR THWN. CONDUCTORS #8 AWG AND LARGER SHALL BE STRANDED COPPER AND HAVE 600 VOLT INSULATION; BE UL LABELED AND OF AMERICAN MANUFACTURER. B.ALL BRANCH CIRCUITS IN OFFICE AND COMMON AREAS SHALL BE MC CABLE. USE MEDICAL GRADE MC CABLE IN PATIENT CARE AREA.. C.ALL CONNECTIONS ARE TO BE MADE USING PRESSURE TYPE TERMINALS. D.THE FOLLOWING COLOR CODE SHALL BE USED: 120/240 VOLT 120/208 VOLT 277/480 VOLT PHASE A BLACK BLACK BROWN PHASE B RED RED ORANGE PHASE C BLUE YELLOW NEUTRAL WHITE WHITE WHITE GROUND GREEN GREEN GREEN E.CONDUCTORS NO. 10 AWG OR SMALLER SHALL HAVE INSULATION COLORED AS NOTED ABOVE. F.CONDUCTORS NO. 8 AWG OR LARGER SHALL HAVE INSULATION COLORED AS NOTED ABOVE OR COLORED TAPE, MINIMUM SIZE 12'', WRAPPED TWICE AROUND AT THE FOLLOWING POINTS: 1.AT EACH TERMINAL. 2.AT EACH CONDUIT ENTRANCE. 3.AT INTERVALS NOT MORE THAN 12 INCHES APART IN ALL BOXES, PANEL TUBS, SWITCHBOARDS, ETC. G.ALL BRANCH CIRCUITS SHALL BE MARKED IN THE PANEL BOARD GUTTERS. MARKERS SHALL INDICATE CORRESPONDING BRANCH--CIRCUIT NUMBERS. H.EACH BRANCH CIRCUIT REQUIRING A NEUTRAL SHALL BE FURNISHED WITH A SEPARATE INDIVIDUAL NEUTRAL CONDUCTOR. BOXES AND PLATES A.FURNISH AND INSTALL ALL OUTLET, JUNCTION, AND PULL BOXES AS INDICATED ON THE DRAWINGS AND AS NECESSARY TO INSTALL THE REQUIRED CONDUIT AND WIRING IN A NEAT AND WORKMANLIKE MANNER. B.PULL BOXES AND JUNCTION BOXES SHALL BE GALVANIZED AND OF THE CORRECT SIZE AND GAUGE, SIZED IN ACCORDANCE WITH CODE REQUIREMENTS AND SHALL BE U.L. LABELED. C.BOXES AT EXTERIOR AREAS TO BE WATERTIGHT AND DUST-TIGHT WITH CASKETED COVERS. D.ALL BOXES FOR EXPOSED WORK IN FINISHED SPACES SHALL BE ''FS'' TYPE WITH THREADED HUBS WITH RIGID CONDUIT RISER (DEEP WIRE MOLD BOXES). E.ALL BOXES SHALL BE RIGIDLY SUPPORTED INDEPENDENT OF THE CONDUIT SYSTEM. BOXES CAST INTO MASONRY OR CONCRETE ARE CONSIDERED TO BE RIGIDLY SUPPORTED. F.FLOOR BOXES: 1.DESCRIPTION: FLOOR BOXES COMPATIBLE WITH FLOOR BOX SERVICE FITTINGS PROVIDED IN ACCORDANCE WITH THE WIRING DEVICES SECTION OF THIS SPECIFICATION; WITH PARTITIONS TO SEPARATE MULTIPLE SERVICES; FURNISHED WITH ALL COMPONENTS, ADAPTERS, AND TRIMS REQUIRED FOR COMPLETE INSTALLATION. 2.USE CAST IRON OR NONMETALLIC FLOOR BOXES WITHIN SLAB ON GRADE. 3.USE SHEET-STEEL, CAST IRON, OR NONMETALLIC FLOOR BOXES WITHIN SLAB ABOVE GRADE. 4.METALLIC FLOOR BOXES: FULLY ADJUSTABLE (WITH INTEGRAL MEANS FOR LEVELING ADJUSTMENT PRIOR TO AND AFTER CONCRETE POUR). 5.MANUFACTURER: SAME AS MANUFACTURER OF FLOOR BOX SERVICE FITTINGS. G.UNDERGROUND BOXES/ENCLOSURES: 1.DESCRIPTION: IN-GROUND, OPEN BOTTOM BOXES FURNISHED WITH FLUSH, NON-SKID COVERS WITH LEGEND INDICATING TYPE OF SERVICE AND STAINLESS STEEL TAMPER RESISTANT COVER BOLTS. 2.SIZE: AS INDICATED ON DRAWINGS. 3.DEPTH: AS REQUIRED TO EXTEND BELOW FROST LINE TO PREVENT FROST UPHEAVAL, BUT NOT LESS THAN 12 INCHES. 4.APPLICATIONS: a.SIDEWALKS AND LANDSCAPED AREAS SUBJECT ONLY TO OCCASIONAL NONDELIBERATE VEHICULAR TRAFFIC: USE POLYMER CONCRETE OR COMPOSITE ENCLOSURE WITH MINIMUM SCTE 77, TIER 8 LOAD RATING. b.PARKING LOTS, IN AREAS SUBJECT ONLY TO OCCASIONAL NONDELIBERATE VEHICULAR TRAFFIC: USE POLYMER CONCRETE OR COMPOSITE ENCLOSURE WITH MINIMUM SCTE 77, TIER 15 LOAD RATING. c.DO NOT USE POLYMER CONCRETE ENCLOSURES IN AREAS SUBJECT TO DELIBERATE VEHICULAR TRAFFIC. H.COMPOSITE UNDERGROUND BOXES/ENCLOSURES: COMPLY WITH SCTE 77. WIRING DEVICES A.WIRING DEVICES SHALL BE SIMILAR TO THOSE LISTED BELOW AND OF SPECIFIED AMPERAGE. OTHER SPECIAL PURPOSE DEVICES SHALL BE AS SPECIFIED ON THE DRAWINGS. B.DUPLEX GROUNDING TYPE RECEPTACLE - 20 AMP, 125 VOLT 1.HUBBELL 5352 2.ARROW HART 5352 C.SINGLE POLE SWITCHES - 20 AMP, 120 VOLT D.WEATHERPROOF RECEPTACLES - 20 AMP, 125 VOLT - NEMA 5-20R 1.HUBBELL 5352 WITH 5205 COVER INTERMATIC GUARDIAN 2.I SERIES, NEMA 3R COVER 3.ARROW HART 5352 WITH 4500 COVER E.G.F.C.I. RECEPTACLE - 20 AMP, 125 VOLT - NEMA 5-20 R 1.HUBBELL GF 5262 WITH MATCHING NYLON COVER PLATE OR WO-26 W.P. COVER F.GROUND ALL RECEPTACLES IN ACCORDANCE WITH ARTICLE 250.146 OF NEC AND AS INDICATED IN THE GROUNDING SECTION OF THIS SPECIFICATION. IDENTIFICATION A.EACH PIECE OF SERVICE EQUIPMENT AND INDIVIDUAL SWITCHES, ALL DISCONNECTS, STARTERS, ALL EXHAUST FAN MANUAL STARTING SWITCHES. B.IDENTIFICATION SHALL BE IN THE FORM OF LAMINATED PLASTIC NAMEPLATES, BLACK RACE, WITH THE LETTERS ENGRAVED INTO THE WHITE BACKGROUND, MINIMUM ¼'' HIGH. PLATES SHALL BE DRILLED ON EACH END FOR SHEET METAL SCREW ATTACHMENT. NO “DYMO” OR SIMILAR TYPE LABELS WILL BE ALLOWED. C.PANEL BOARD DIRECTORY: A TYPED CIRCUIT DIRECTORY SHALL BE PROVIDED INDICATING LOCAL AREA SERVED AND LOCATION FOR EACH BRANCH CIRCUIT. GROUNDING A.ALL FEEDERS AND BRANCH CIRCUITS OVER 100 VOLTS SHALL INCLUDE A GROUNDING CONDUCTOR SIZED IN ACCORDANCE WITH NEC TABLE 250-122, EXCEPT NOT BE SMALLER THAN #12 FOR POWER AND LIGHTING CIRCUITS AND #14 FOR CONTROL CIRCUITS. ALL GROUND CONDUCTORS SHALL BE GREEN, OR AS SPECIFIED UNDER THE WIRE AND CABLE SECTION OF THIS SPECIFICATION. B.ALL GROUND CLAMPS SHALL BE PENN-UNION “GPL” TYPE OR SIMILAR BY O.Z. OR BURNDY. C.CONDUIT FOR SOLITARY GROUND CONDUCTORS SHALL BE RIGID SCHEDULE 40 PVC NON- METALLIC ELECTRICAL CONDUIT WITH U.L. LABEL SOLITARY GROUND CONDUCTORS SHALL NOT BE PLACED THROUGH METALLIC SLEEVES OR CONDUITS AND SHALL NOT BE COMPLETELY ENCIRCLED BY METALLIC HANGERS OR SUPPORTS. D.THE GROUND CONDUCTOR SHALL BE CONNECTED TO THE NEUTRAL IN ONLY TWO LOCATIONS -ON THE SUPPLY SIDE OF THE SERVICE DISCONNECT MEANS PER NEC--250--24 AND ON SEPARATELY DERIVED SYSTEMS PER NEC 250-30. E.AT EACH RECEPTACLE BOX, THE GROUND CONDUCTOR SHALL ENTER AND CONNECT, WITH NORMAL WIRING CONNECTOR, TO: 1) THE GROUND PIGTAIL TO RECEPTACLE: 2) THE GROUND PIGTAIL TO THE BOX GROUND SCREW; AND 3) THE OUTGOING GROUND CONDUCTOR TO NEXT DEVICE, IF NOT AT END OF RUN. METAL TO METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE. MOUNTED BOXES OR FLUSH TYPE BOXES. F.CONDUIT SYSTEM SHALL BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS SHALL CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON-CURRENT CARRYING METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. WHERE REDUCING WASHERS ARE USED AND WHERE CONCENTRIC OR ECCENTRIC KNOCKOUTS ARE NOT COMPLETELY REMOVED BONDING BUSHINGS SHALL BE REQUIRED. POWER AND LIGHTING PANELS A.FURNISH AND INSTALL, AS SCHEDULED AND SHOWN ON THE DRAWINGS, POWER PANELS FOR OPERATION ON VOLTAGES INDICATED. B.ALL TERMINATIONS SHALL BE MARKED “75°C ONLY”, “60/75° C” OR LISTED FOR USE OF 75° C INSULATED CONDUCTORS AT FULL 75° C AMPACITY. C.ALL BUS BARS SHALL BE SILVER OR TIN PLATED COPPER. D.CABINETS SHALL BE OF COMMERCIAL GALVANIZED SHEET STEEL, CODE GAUGE AND SIZE, SURFACE OR RECESSED MOUNTED AS CALLED FOR IN THE DRAWINGS. E.NEUTRAL ASSEMBLY SHALL HAVE INDIVIDUAL ANTI-TURN SOLDERLESS TERMINALS, SIMILAR TO SQUARE D TYPE PK, FOR CONNECTION OF ULTIMATE NUMBER OF NEUTRAL WIRES. SHEET METAL TERMINAL STRIPS AND CONNECTIONS WILL BE REJECTED. F.PANEL SHALL HAVE A COPPER GROUND BAR SIMILAR TO NEUTRAL BAR IN NUMBER, SIZE, AND TYPE OF ANTI-TURN SOLDERLESS LUGS. THIS GROUND BAR SHALL BE FACTORY BONDED TO THE PANEL TUB IN THE GUTTER SPACE OPPOSITE THE MAINS AND THE NEUTRAL ASSEMBLY AND SHALL HAVE THE SCREWDRIVER SLOTS FACING THE FRONT OF THE PANEL. G.QUALITY STANDARD: SQUARE D TYPE NQ. LIGHTING FIXTURES A.CONTRACTOR SHALL FURNISH AND INSTALL LIGHTING FIXTURES AS INDICATED IN FIXTURE SCHEDULE SHOWN ON DRAWINGS, AND SPECIFIED HEREIN. B.NEUTRAL ASSEMBLY SHALL HAVE INDIVIDUAL ANTI-TURN SOLDERLESS TERMINALS, SIMILAR TO SQUARE D TYPE PK, FOR CONNECTION OF ULTIMATE NUMBER OF NEUTRAL WIRES. SHEET METAL TERMINAL STRIPS AND CONNECTIONS WILL BE REJECTED. C.ALL LIGHTING FIXTURES INSTALLED BY THE ELECTRICAL CONTRACTOR SHALL BE FURNISHED COMPLETE WITH AS INDICATED ON THE FIXTURE SCHEDULE. D.ANY LIGHTING FIXTURES SCRATCHED, BENT, CRACKED OR IN ANY WAY DAMAGED BEFORE ACCEPTANCE BY OWNER SHALL BE REPLACED AT THIS CONTRACTOR'S EXPENSE. E.ALL LIGHTING FIXTURES SHALL BE IN WORKING ORDER AT THE TIME OF FINAL ACCEPTANCE OF THE WORK BY THE OWNER. F.ALL LIGHTING FIXTURES ARE TO BE GROUNDED ON THE INTERIOR OF THE FIXTURE HOUSING, ON CLEAN BARE METAL (FREE OF PAINT). BY USE OF PIGTAIL AND FASTENED BY A SCREW USED FOR NO OTHER PURPOSE. ALARM & DETECTION SYSTEMS A.SUMMARY 1.INCLUDES BUT NOT LIMITED TO: FURNISH AND INSTALL MICROPROCESSOR-CONTROLLED, INTELLIGENT REPORTING FIRE ALARM EQUIPMENT REQUIRED TO FORM A COMPLETE COORDINATED SYSTEM THAT IS READY FOR OPERATION. B.SYSTEM DESCRIPTION 1.THE FIRE ALARM SYSTEM SHALL COMPLY WITH REQUIREMENTS OF NFPA STANDARD NO. 72 FOR PROTECTED PREMISES SIGNALING SYSTEMS EXCEPT AS MODIFIED AND SUPPLEMENTED BY THIS SPECIFICATION. THE SYSTEM SHALL BE ELECTRICALLY SUPERVISED AND MONITOR THE INTEGRITY OF ALL CONDUCTORS. 2.THE SYSTEM SHALL BE AN ACTIVE/INTERROGATIVE TYPE SYSTEM WHERE EACH DEVICE IS REPETITIVELY SCANNED, CAUSING A SIGNAL TO BE TRANSMITTED TO THE MAIN FIRE ALARM CONTROL PANEL (FACP) INDICATING THAT THE ASSOCIATED INITIATING DEVICE AND NOTIFICATION APPLIANCE CIRCUIT WIRING IS FUNCTIONAL. LOSS OF SUCH A SIGNAL AT THE MAIN FACP SHALL RESULT IN A TROUBLE INDICATION AS SPECIFIED HEREINAFTER FOR THE PARTICULAR INPUT. 3.SYSTEM OPERATION: OPERATION OF MANUAL STATION OR AUTOMATIC ACTIVATION OF ANY SMOKE DETECTOR OR HEAT DETECTOR SHALL: a.CAUSE SYSTEM EVACUATION HORNS TO SOUND AND LAMPS TO FLASH. b.THE 80 CHARACTER LCD DISPLAY SHALL INDICATE ALL INFORMATION ASSOCIATED WITH THE FIRE ALARM CONDITION, INCLUDING THE TYPE OF ALARM POINT AND ITS LOCATION WITHIN THE PROTECTED PREMISES. c.INITIATE OFF-SITE ALARM NOTIFICATION. d.RELEASE MAGNETIC DOOR HOLDERS. e.INITIATE SHUT DOWN OF MECHANICAL UNITS WITH AIR FLOW IN EXCESS OF 2000CFM. f.INITIATE CLOSURE OF ALL FIRE/SMOKE DAMPERS. 4.WIRING: THE MULTIPLEX BUSS AND DATA COMMUNICATION BUS (OPTIONS BUS) SHALL BE WIRED WITH STANDARD NEC 760 COMPLIANT WIRING. ALL FACP SCREW TERMINALS SHALL BE CAPABLE OF ACCEPTING 14 AWG (1.8 MM) TO 18 AWG (1.2 MM) WIRE. ALL SYSTEM WIRING SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 70, THE NATIONAL ELECTRICAL CODE (NEC) AND ALSO COMPLY WITH ARTICLE 760 OF THE NEC. C.QUALITY ASSURANCE 1.REGULATORY REQUIREMENTS a.SYSTEM SHALL MEET APPROVAL OF AUTHORITY HAVING JURISDICTION (AHJ). CHANGES OR ADDITIONS SHALL BE MADE TO THE SYSTEM AS REQUIRED WITHOUT ADDITIONAL COST TO OWNER. b.EQUIPMENT, DEVICES, AND CABLE SHALL BE UL OR FACTORY MUTUAL LISTED FOR USE IN FIRE ALARM SYSTEMS. c.DESIGNER QUALIFICATIONS: NICET LEVEL III OR IV (3 OR 4) CERTIFIED FIRE ALARM TECHNICIAN OR REGISTERED FIRE PROTECTION ENGINEER, EMPLOYED BY FIRE ALARM CONTROL PANEL MANUFACTURER, CONTRACTOR, OR INSTALLER. d.INSTALLER QUALIFICATIONS: FIRM WITH MINIMUM 3 YEARS DOCUMENTED EXPERIENCE INSTALLING FIRE ALARM SYSTEMS OF THE SPECIFIED TYPE AND PROVIDING CONTRACT MAINTENANCE SERVICE AS A REGULAR PART OF THEIR BUSINESS. 1)AUTHORIZED REPRESENTATIVE OF CONTROL UNIT MANUFACTURER; SUBMIT MANUFACTURER'S CERTIFICATION THAT INSTALLER IS AUTHORIZED; INCLUDE NAME AND TITLE OF MANUFACTURER'S REPRESENTATIVE MAKING CERTIFICATION. 2)INSTALLER PERSONNEL: FACTORY TRAINED AND CERTIFIED WITH AT LEAST 2 YEARS OF EXPERIENCE INSTALLING FIRE ALARM SYSTEMS. 3)SUPERVISOR: NICET LEVEL III OR IV (3 OR 4) CERTIFIED FIRE ALARM TECHNICIAN; FURNISH NAME AND ADDRESS. D.FACP COMPONENTS: 1.EQUIPMENT AND ACCESSORIES FURNISHED UNDER TERMS OF THIS SPECIFICATION SHALL BE STANDARD PRODUCTS OF SINGLE MANUFACTURER, OR INCLUDE WRITTEN STATEMENT BY CONTROL PANEL MANUFACTURER CONFIRMING COMPATIBILITY OF COMPONENTS AND INCLUSION OF THESE COMPONENTS UNDER SYSTEM WARRANTY. 2.THE MAIN FACP CENTRAL CONSOLE SHALL CONTAIN A MICROPROCESSOR BASED CENTRAL PROCESSING UNIT (CPU). THE FACP SHALL COMMUNICATE WITH AND CONTROL THE FOLLOWING TYPES OF EQUIPMENT USED TO MAKE UP THE SYSTEM: ADDRESSABLE DETECTORS, ADDRESSABLE MODULES, LOCAL AND REMOTE OPERATOR TERMINALS, ANNUNCIATORS, AND OTHER SYSTEM CONTROLLED DEVICES. a.THE MAIN FACP AND CENTRAL CONSOLE SHALL PERFORM THE FOLLOWING FUNCTIONS: b.SUPERVISE AND MONITOR ALL ADDRESSABLE DETECTORS AND MONITOR MODULES CONNECTED TO THE SYSTEM FOR NORMAL, TROUBLE AND ALARM CONDITIONS. c.SUPERVISE ALL NOTIFICATION CIRCUITS THROUGHOUT THE FACILITY. d.VISUALLY AND AUDIBLY ANNUNCIATE ANY TROUBLE, SUPERVISORY OR ALARM CONDITION ON OPERATOR'S TERMINAL, PANEL DISPLAY, AND ANNUNCIATORS. 3.THE FIRE ALARM CONTROL PANEL SHALL INCLUDE A FULL FEATURED OPERATOR INTERFACE CONTROL AND ANNUNCIATION PANEL WHICH SHALL INCLUDE A BACKLIT LIQUID CRYSTAL DISPLAY, INDIVIDUAL, COLOR CODED SYSTEM STATUS LEDS, AND AN ALPHA-NUMERIC KEYPAD FOR FIELD PROGRAMMING AND CONTROL OF THE FIRE ALARM SYSTEM. 4.THE SYSTEM SHALL INCLUDE EMERGENCY EVACUATION SIGNAL UTILIZING INTELLIGENCE SUCH THAT LOSS OF OPERATION BY THE MAIN FACP WILL NOT RESULT IN THE LOSS OF EVACUATION SIGNAL THROUGHOUT THE BALANCE OF THE BUILDING. 5.THE MAIN COMMUNICATION BUS (OPTIONS BUS) SHALL BE CAPABLE OF CLASS A OR CLASS B CONFIGURATION WITH A TOTAL BUS LENGTH OF 5,900 FEET (1,798 M). 6.OFF-SITE ALARM NOTIFICATION SYSTEM a.PROVIDE TELEPHONE LINE CONNECTION FROM TELEPHONE TERMINAL BOARD TO FIRE ALARM CONTROL PANEL. b.PROVIDE DIALER DEVICE TO NOTIFY OFF-SITE PERSONNEL OF ALARM OR ABNORMAL CONDITIONS. c.CONNECT TO FIRE ALARM CONTROL PANEL SO SPECIFIED CONDITIONS INITIATE OFF-SITE CALL. USE ONE ALARM CODE FOR ALARM AND SECOND CODE FOR SUPERVISORY/TROUBLE ALARM. 7.AUDIBLE HORN ALARM ANNUNCIATION a.PROVIDE SEPARATE AND DISTINCT ALARM SIGNALS FOR ALARM AND TROUBLE CONDITIONS. b.ALARM SIGNAL SHALL ALSO OPERATE STROBE LIGHTS, IF SPECIFIED. c.PROVIDE ALARM SILENCE SWITCHES AT CONTROL PANEL. d.TROUBLE ALARM SHALL BE HORN INTEGRAL TO CONTROL PANEL. e.SUPERVISORY ALARM MAY BE SAME AUDIBLE ALARM AS TROUBLE ALARM, BUT WITH SEPARATE VISUAL ANNUNCIATION. E.FIELD MOUNTED SYSTEM COMPONENTS 1.FIRE ALARM INITIATING DEVICES a.DUCT DETECTOR HOUSING: PROVIDE SMOKE DETECTOR DUCT HOUSING ASSEMBLIES TO MOUNT AN ADDRESSABLE DETECTOR ALONG WITH A STANDARD, RELAY OR ISOLATOR DETECTOR MOUNTING BASE. THE HOUSING SHALL ALSO PROTECT THE MEASURING CHAMBER FROM DAMAGE AND INSECTS. THE HOUSING SHALL UTILIZE AN AIR EXHAUST TUBE AND AN AIR SAMPLING INLET TUBE THAT EXTENDS INTO THE DUCT AIR STREAM UP TO TEN FEET. DRILLING TEMPLATES AND GASKETS TO FACILITATE LOCATING AND MOUNTING THE HOUSING SHALL ALSO BE PROVIDED. THE HOUSING SHALL BE FINISHED IN BAKED RED ENAMEL. REMOTE ALARM LED INDICATORS AND REMOTE TEST STATIONS SHALL BE PROVIDED. b.ADDRESSABLE SMOKE DETECTORS 1)CEILING MOUNTED, ADDRESSABLE PHOTOELECTRIC 2)UL LISTED COMPATIBLE WITH THE FIRE ALARM CONTROL PANEL. 3)SHALL HAVE A FLASHING STATUS LED FOR VISUAL SUPERVISION. WHEN THE DETECTOR IS ACTUATED, THE FLASHING LED WILL LATCH ON SOLID. THE LED SHALL FLASH AT A 1/SEC RATE IF THE CHAMBER IS OUT OF CALIBRATION RANGE. THE DETECTOR MAY BE RESET BY ACTUATING THE CONTROL PANEL'S RESET SWITCH. c.SMOKE DETECTOR GUARDS 1)UNDERWRITERS LABORATORIES TESTED AND LISTED BY FOR USE WITH THE SMOKE DETECTORS THEY PROTECT. 2)GUARD DESIGN SHALL NOT AFFECT THE DETECTOR OPERATING SENSITIVITY AND SHALL NOT REDUCE THE LISTED DETECTOR SPACING. 3)CONSTRUCTED OF 16-GAUGE STEEL WITH A BAKED WHITE FINISH TO MATCH THE DETECTORS. 4)TAMPERPROOF MOUNTING HARDWARE SHALL BE PROVIDED. d.ADDRESSABLE FIXED TEMPERATURE-ROR HEAT DETECTOR 1)ADDRESSABLE COMBINATION FIXED TEMPERATURE / RATE-OF-RISE 2)NOMINAL FIXED TEMPERATURE ALARM POINT RATING OF 135°F (57°C) AND A RATE OF RISE ALARM POINT OF 15°F(9°C) PER MINUTE. 3)RATED FOR CEILING INSTALLATION AT A MINIMUM OF 70 FT (21.3M) CENTERS AND BE SUITABLE FOR WALL MOUNT APPLICATIONS. e.DETECTOR BASES: STANDARD DETECTOR MOUNTING BASES SUITABLE FOR MOUNTING ON EITHER NORTH AMERICAN 1-GANG, 3½ OR 4 INCH OCTAGON BOX AND 4 INCH SQUARE BOX, OR EUROPEAN BESA OR 1-GANG BOX. THE BASE SHALL, CONTAIN NO ELECTRONICS AND SUPPORT ALL SERIES DETECTOR TYPES. f.ADDRESSABLE MANUAL STATION 1)ADDRESSABLE DOUBLE ACTION, SINGLE STAGE 2)POLYCARBONATE CONSTRUCTION WITH INTERNAL TOGGLE SWITCH. 3)FINISHED IN RED WITH SILVER "PULL IN CASE OF FIRE" LETTERING 4)SUITABLE FOR MOUNTING ON NORTH AMERICAN 2 ½ (64MM) DEEP 1-GANG BOXES AND 1 ½ (38MM) DEEP 4 SQUARE BOXES WITH 1-GANG COVERS. 2.FIRE ALARM ACTUATING DEVICES a.DOOR HOLDING DEVICES: DOOR RELEASE UNITS SHALL BE ELECTRICALLY OPERATED MAGNETIC DEVICES WHICH HOLD DOORS OPEN UNTIL RELEASED BY THE MAIN CONTROL UNIT. PROVIDE DOOR PLATES AND COORDINATE WITH THE GENERAL CONTRACTOR TO INSURE THAT THE PLATES ARE PROPERLY MOUNTED ON THE DOORS. b.NOTIFICATION APPLIANCES 1)LOW PROFILE HORN-STROBES a)AUDIBLE OUTPUT OF 92 DBA AT 10 FT. WHEN MEASURED IN REVERBERATION ROOM PER UL-464. b)INTEGRALLY MOUNTED FLASHING LIGHT UNIT WITH BLOCK LETTERS 'FIRE'. MULTI-CANDELA WITH FIELD-SELECTABLE SETTINGS OF 15CD, 30CD, 60CD, 75CD & 110CD, AND FLASH RATE BETWEEN ONE AND THREE HERTZ. ALL UNITS SHALL FLASH IN SYNCHRONIZATION WITH EACH OTHER. c)THE HORN SHALL HAVE A SELECTABLE STEADY OR SYNCHRONIZED TEMPORAL OUTPUT. d)IN AND OUT SCREW TERMINALS SHALL BE PROVIDED FOR WIRING. e)LOW PROFILE HORN/STROBES SHALL MOUNT IN A NORTH AMERICAN 1-GANG BOX. 2)LOW PROFILE STROBES a)PROVIDE LOW PROFILE WALL MOUNTED STROBES AT THE LOCATIONS SHOWN ON THE DRAWINGS. IN AND OUT SCREW TERMINALS SHALL BE PROVIDED FOR WIRING. STROBES SHALL PROVIDE SYNCHRONIZED FLASH OUTPUTS. STROBE OUTPUT SHALL BE DETERMINED AS REQUIRED BY ITS SPECIFIC LOCATION AND APPLICATION FROM A FAMILY OF 15CD, 30CD, 60CD, 75CD, OR 110CD DEVICES. LOW PROFILE STROBES SHALL MOUNT IN A NORTH AMERICAN 1-GANG BOX. 3.INITIATION & CONTROL MODULES a.RELAY MODULE 1)PROVIDE ADDRESSABLE CONTROL RELAY CIRCUIT MODULES AS REQUIRED. THE MODULE SHALL PROVIDE ONE (1) FORM C DRY RELAY CONTACTS RATED AT 24VDC @ 2 AMPS (PILOT DUTY) TO CONTROL EXTERNAL APPLIANCES OR EQUIPMENT. THE POSITION OF THE RELAY CONTACT SHALL BE CONFIRMED BY THE SYSTEM FIRMWARE. F.BATTERIES 1.SHALL BE 12 VOLT, GELL-CELL TYPE. 2.BATTERY SHALL HAVE SUFFICIENT CAPACITY TO POWER THE FIRE ALARM SYSTEM FOR NOT LESS THAN TWENTY-FOUR HOURS PLUS 5 MINUTES OF ALARM UPON A NORMAL AC POWER FAILURE. 3.THE BATTERIES ARE TO BE COMPLETELY MAINTENANCE FREE. NO LIQUIDS ARE REQUIRED. FLUID LEVEL CHECKS REFILLING, SPILLS AND LEAKAGE SHALL NOT BE REQUIRED. G.INSTALLATION 1.INSTALL FIRE ALARM AND DETECTION SYSTEMS AS INDICATED, IN ACCORDANCE WITH EQUIPMENT MANUFACTURER'S WRITTEN INSTRUCTIONS, AND COMPLYING WITH APPLICABLE PORTIONS OF NEC, NFPA AND NECA'S "STANDARD OF INSTALLATION". 2.INSTALL WIRING, RACEWAYS, CONDUCTORS, ELECTRICAL BOXES AND FITTINGS IN ACCORDANCE WITH CONDUIT, WIRE AND CABLE, AND BOXES AND PLATES SECTION OF THIS SPECIFICATION. 3.LABEL PULL AND JUNCTION BOXES "FIRE ALARM" WITH RED INDELIBLE INK. 4.LOOP WIRES THROUGH EACH DEVICE ON ZONE FOR PROPER SUPERVISION. TEE-TAPS NOT PERMITTED. 5.PROVIDE DUST PROTECTION FOR INSTALLED SMOKE DETECTORS UNTIL FINISH WORK IS COMPLETED AND BUILDING IS READY FOR OCCUPANCY. 6.PROTECT CONDUCTORS FROM CUTS, ABRASION AND OTHER DAMAGE DURING CONSTRUCTION. 7.MINIMUM CONDUCTOR SIZE SHALL BE 14 AWG UNLESS OTHERWISE SPECIFIED. 8.DO NOT INSTALL CEILING MOUNTED DETECTORS WITHIN 3 FEET OF AIR DISCHARGE GRILLS. COORDINATE WITH OTHER TRADES AS REQUIRED. 9.POST COPY OF WIRE IDENTIFICATION LIST INSIDE FIRE ALARM PANEL DOOR OR OTHER AREA ACCESSIBLE TO FIRE ALARM SERVICE PERSONNEL. 10.PROVIDE DUCT SMOKE DETECTORS FOR ALL MECHANICAL UNITS WITH AIR FLOW IN EXCESS OF 2000 CFM AND TIE INTO FIRE ALARM CONTROL PANEL. PROVIDE FAN SHUT DOWN CIRCUIT AND ASSOCIATED CONTROL EQUIPMENT FOR ALL REQUIRED MECHANICAL UNITS. 11.INSTALL CONDUCTORS AND MAKE CONNECTIONS TO ALL, WATER FLOW SWITCHES, VALVE TAMPER SWITCHES, LOW AIR PRESSURE SWITCHES, AND DOOR HOLDING DEVICES. 12.INSTALL CONDUCTORS AND MAKE CONNECTIONS TO ALL FIRE/SMOKE DAMPERS. REFER TO MECHANICAL DRAWINGS FOR EXACT NUMBER AND LOCATIONS. H.FIELD QUALITY CONTROL 1.TEST & INSPECTION a.ALL INTELLIGENT ADDRESSABLE DEVICES SHALL BE TESTED FOR CURRENT ADDRESS AND USER DEFINED MESSAGE. b.ALL WIRING SHALL BE TESTED FOR CONTINUITY, SHORTS, AND GROUNDS BEFORE THE SYSTEM IS ACTIVATED. c.ALL TEST EQUIPMENT, INSTRUMENTS, TOOLS AND LABOR REQUIRED TO CONDUCT THE TESTS SHALL BE MADE AVAILABLE BY THE INSTALLING CONTRACTOR. d.THE SYSTEM INCLUDING ALL ITS SEQUENCE OF OPERATIONS SHALL BE DEMONSTRATED TO THE OWNER, HIS REPRESENTATIVE, AND THE LOCAL FIRE INSPECTOR. IN THE EVENT THE SYSTEM DOES NOT OPERATE PROPERLY, THE TEST SHALL BE TERMINATED. CORRECTIONS SHALL BE MADE AND THE TESTING PROCEDURE SHALL BE REPEATED UNTIL IT IS ACCEPTABLE TO THE OWNER, HIS REPRESENTATIVES AND THE FIRE INSPECTOR. e.ALL FIRE ALARM TESTING SHALL BE IN ACCORDANCE WITH NATIONAL FIRE ALARM CODE, NFPA 72. I.MANUFACTURER'S FIELD SERVICE 1.INSTRUCT OWNER'S REPRESENTATIVE IN PROPER OPERATION AND MAINTENANCE PROCEDURES. 2.PROVIDE A MINIMUM OF 4 HOURS TRAINING. TELEPHONE/DATA SYSTEMS A.SUMMARY 1.INCLUDES BUT NOT LIMITED TO a.FURNISH AND INSTALL BUILDING TELEPHONE AND COMPUTER NETWORK RACEWAY AND CABLE SYSTEM AS DESCRIBED IN CONTRACT DOCUMENTS INCLUDING, BUT NOT LIMITED TO, RACEWAY, OUTLETS, MODULAR JACKS, DEVICE PLATES, CABLES, PUNCH DOWN BLOCKS, BACKBOARDS, CABINETS, PATCH PANELS, GROUNDING AND OTHER MISCELLANEOUS ITEMS REQUIRED FOR A COMPLETE SYSTEM. b.FURNISH AND INSTALL MAIN SERVICE RACEWAY AS DESCRIBED IN CONTRACT DOCUMENTS AND TO COMPLY WITH TELEPHONE COMPANY REQUIREMENTS. B.COMPONENTS 1.TELEPHONE OUTLET BOX SHALL BE SINGLE DEVICE BOX. 2.BUILDING TELEPHONE AND COMPUTER NETWORK SYSTEM CABLE a.23 GAUGE, SOLID TINNED COPPER, FOUR TWISTED PAIRS. CATEGORY 6 b.USE PLENUM-RATED CABLE IN CEILINGS AND AREAS USED FOR PLENUM AIR RETURN 3.TELEPHONE TERMINATION BLOCKS a.UL VERIFIED CATEGORY 6. b.110 TERMINATION WITH TIN LEAD PLATED IDC 4.NETWORK PATCH PANELS a.UL VERIFIED CATEGORY 6 b.110 TERMINATION WITH TIN LEAD PLATED IDC c.19" RACK MOUNT WITH BACKBOARD MOUNTING FRAME. d.48 PORTS 5.TELEPHONE/NETWORK JACKS a.WALL JACKS 1)CAT6 - HUBBELL HXJ6 OR ALTERNATE MANUFACTURER WITH EQUIVALENT PERFORMANCE STANDARD. b.PLATES 1)HUBBELL - IFP SERIES (PORT QUANTITY AS REQUIRED, COLOR BY ARCHITECT) 6.BACKBOARDS: INTERIOR GRADE PLYWOOD WITHOUT VOIDS, 3 4 INCH THICK; UL-LABELED FIRE RETARDANT. a.SIZE: 48 INCHES WIDE 96 INCHES HIGH. b.DO NOT PAINT OVER UL LABEL. c.PROVIDE ONE 48" MULTI-OUTLET POWER STRIP WITH INTEGRAL SURGE PROTECTION AND OUTLETS AT 6" O.C. (MINIMUM 7 OUTLETS) MOUNTED AT CENTER OF TERMINAL BOARD. 7.EQUIPMENT RACKS AND CABINETS: CEA-310 STANDARD 19 INCH WIDE COMPONENT RACKS. a.FLOOR MOUNTED RACKS: 16 GAGE STEEL CONSTRUCTION WITH CORROSION RESISTANT FINISH; VERTICAL AND HORIZONTAL CABLE MANAGEMENT CHANNELS, TOP AND BOTTOM CABLE TROUGHS, AND GROUNDING LUG. 8.CONNECTOR BLOCKS FOR CATEGORY 6 AND UP CABLING: TYPE 110 INSULATION DISPLACEMENT CONNECTORS; CAPACITY SUFFICIENT FOR CABLES TO BE TERMINATED PLUS 25 PERCENT SPARE. 9.PATCH PANELS FOR COPPER CABLING: SIZED TO FIT EIA STANDARD 19 INCH WIDE EQUIPMENT RACKS; 0.09 INCH THICK ALUMINUM; CABLING TERMINATED ON TYPE 110 INSULATION DISPLACEMENT CONNECTORS; PRINTED CIRCUIT BOARD INTERFACE. a.JACKS: NON-KEYED RJ-45, SUITABLE FOR AND COMPLYING WITH SAME STANDARDS CABLE TO BE TERMINATED; MAXIMUM 48 PORTS PER STANDARD WIDTH PANEL. b.CAPACITY: PROVIDE PORTS SUFFICIENT FOR CABLES TO BE TERMINATED PLUS 25 PERCENT SPARE PLUS MOUNTING SPACE FOR ALL ACTIVE COMPONENTS/EQUIPMENT REQUIRED TO CROSS-CONNECT TO ANY/ALL MODULAR JACK PORTS ON THE PATCH PANELS. c.LABELS: FACTORY INSTALLED LAMINATED PLASTIC NAMEPLATES ABOVE EACH PORT, NUMBERED CONSECUTIVELY; COMPLY WITH TIA/EIA-606 USING ENCODED IDENTIFIERS. d.PROVIDE INCOMING CABLE STRAIN RELIEF AND ROUTING GUIDES ON BACK OF PANEL. e.PATCH CORDS: PROVIDE ONE PATCH CORD FOR EACH PAIR OF PATCH PANEL PORTS. 10.CABLE MANAGEMENT a.EQUIP EACH RACK OR CABINET WITH VERTICAL CABLE SECTION. b.EQUIP EACH RACK OR CABINET WITH HORIZONTAL CABLE MANAGERS ABOVE AND BELOW EACH PATCH SECTION. 1)7 RINGS 2)6 PASS-THROUGH HOLES 3)HINGED FRONT COVER c.USE VELCRO CABLE WRAPS ON ALL CABLE - TIE WRAPS ARE NOT ACCEPTABLE. C.INSTALLATION 1.RUN 1" CONDUIT TO ACCESSIBLE CEILING SPACE FROM EACH OUTLET. INSTALL CABLE FROM TERMINAL BOARD TO EACH TELEPHONE/NETWORK OUTLET. 2.TERMINATE CABLES AT EACH OUTLET WITH SPECIFIED MODULAR JACK ASSEMBLY. 3.TERMINATE CABLES ON PUNCH DOWN BLOCKS OR PATCH PANELS AT TERMINAL BOARD. 4.PROVIDE TYPED LABELS AT ALL JACKS CORRESPONDING TO TYPED NUMBERING SYSTEM AT PATCH PANEL OR TERMINAL STRIP. D.QUALITY ASSURANCE 1.COMPLY WITH APPLICABLE PORTIONS OF NEC ANSI/EIA/TIA 568 AS TO TYPE PRODUCTS USED AND INSTALLATION OF COMPONENTS. PROVIDE PRODUCTS AND MATERIALS WHICH HAVE BEEN UL-LISTED AND LABELED. ISSUE DATE: PROJECT NO: DRAWN BY: CHECKED BY: clarity design group architecture - planning - interiors 5525 south 900 east, ste 340 IF THESE PLANS DO NOT BEAR THE SEAL OF A REGISTRANT, THEY ARE TO BE CONSIDERED "PRELIMINARY" AND ARE NOT TO BE USED FOR CONSTRUCTION OR RECORDING. THESE PLANS ARE COPYRIGHTED UNDER SEC. 102 OF THE COPYRIGHT ACT, 17 U.S.O. AS AMENDED DECEMBER 1990 AND KNOWN AS ARCHITECTURAL WORKS COPYRIGHT PROTECTION ACT OF 1990. p. 385.247.8570 www.claritydesign.us SHEET TITLE murray, utah 84117 PROJECT CONSULTANTS Z: \ P r o j e c t s \ J 2 3 \ J 2 3 0 1 2 . 0 0 \ A r c h i t e c t u r a l \ 0 1 C o n t r a c t D o c u m e n t s \ 2 0 2 3 - 0 1 - 1 8 - R e v i t F i l e \ R e x b u r g \ R e v i t \ C o n n e c t i o n s _ R e x b u r g _ C . r v t 1/ 1 9 / 2 0 2 3 2 : 5 8 : 4 3 P M © 2023 CLARITY DESIGN GROUP 03.15.2023 PS RB 21058 CONNECTIONS LOT 13, LOT 14 450, 470 FIRST AMERICAN CIR REXBURG, ID 83440 FOR CONSTRUCTION #DATE DESCRIPTION THESE DOCUMENTS ARE INSTRUMENTS OF PROFESSIONAL SERVICE AND THE INFORMATION CONTAINED HEREIN IS INCOMPLETE UNLESS IN CONJUNCTION WITH ROYAL ENGINEERING'S INTERPRETATIONS, DECISIONS, OBSERVATIONS AND ADMINISTRATIONS. USE OR REPRODUCTION OF THESE DOCUMENTS IN WHOLE OR IN PART WITHOUT ROYAL ENGINEERING'S CONSENT IS IN VIOLATION OF COMMON LAW. COPYRIGHTS, STATUTORY AND OTHER RESERVED RIGHTS. REFER TO ACT 17 U.S.C. PAR. 511 (1991). WHICH PREEMPTS STATE AND LOCAL PUBLIC RECORD ACTS. REFER TO ACT 17 U.S.C. PAR. 301 (1991). COPYRIGHT ©JOB#DATE PLOTTED:03/31/2023 MECHANICAL PROVO, UTAH 84606 FAX: 801.375.2676 ELECTRICAL 1837 S. EAST BAY BLVD. PHONE: 801.375.2228 J23012.00 E-7.1 ELECTRICAL SPECIFICATIONS