HomeMy WebLinkAboutPLANS - 22-00161 - Muir Home22" LAP (Typ) 22 " L A P (T Y P ) Span (See Table) Span (See table) Le n g t h ( A s p e r A r c h D r a w i n g s 3' - 0 " Ma x . #4 @ 2'-0" O.C. E. W. 23/32 APA Rated Sheathing W/ Tar Paper Between Sheathing and Concrete Tar Paper 2x Pressure Treated Rim (Match Floor Joist Depth) #4 @ 2'-0" O.C. 24 2x4 Pressure Treated Sill Plate W/1/2" Dia. Anchor Bolts @ 4'-0" O.C. Wall Framing (By Others) Floor Framing (By Others) 1 1/4" (Min.) Eng Rim Joist Foundation Wall (By Others) Floor Joist (See Table) 2x Ledger W/Simpson 1/4" SDS Screws (Match Floor Joist Depth) (See Table) Simpson LUS Joist Hanger W/ SD Screws @ Each Joist Slope Cold Storage Detail Scale: 1/4"=1'-0" UNO D Size Paper Scale: 1/8"=1'-0" UNO B Size Paper Grade (2) #4 Rebar Horiz. Cont. 16x8 Cont. Footing 6" Conc. FDN Wall 2x4 Pony Wall 11 7/8" Eng. Floor Joist to be Sunken with Hanger or Pony Wall Support Wall Tile Recessed Floor Drain Detail (APA) 2x Wall 5/8" Gypsum Board 3/4" APA Rated Floor Sheathing Tile Backer Board Over 6mm Vapor Barrier Floor Tile Sloped Grout Bed 3/4" APA Rated Floor Sheathing 11 7/8" LVL Floor Joist 9 1/2" TJI Floor Joist Rim Down Joist Detail (USE IF APPLICABLE)(USE IF APPLICABLE) Day Light Basement 3' Foundation Wall with earth backfill @ 2'-6" 2' 6' 3' 8' - 1 1 / 2 " B-B 1' - 0 1 / 2 " 5' - 9 1 / 2 " 3' - 4 " 8" A-A 1' - 0 1 / 2 " A A B B 2' - 6 " 6 " M i n A-A B-B Stepping Conc. Daylight Stepping and Walkout Foundation (USE IF APPLICABLE) Fasten sheathing to header w 8d common or gal. box nails in 3" grid pattern as shown Header to jack-stud strap per table R602.10.6.4 on both sides of opening opposite side of sheathing Min. Length of panel per Table R602.10.5 Min. double 2x4 framing covered w min.7/16" thick wood structual panel sheathing w 8d common or gal. box nails at 3" o.c. in framing (studs and sills) as shown. typ. Min. (2) 3500 LB Tie-Down Device (Embedded into Concrete and Nailed into Framing) Min.(1)5/8" ∅ Anchor Bolts R403.1.6 with 2"x2"x3/16" plate washer Min. Double 2x4 Post Typical Portal Frame Construction If needed, panel splice edges shall occur over & be nailed to common blocking w/in middle 24" of wall mid-height. One row of 3" o.c. nailing is req. in ea. panel edge Min. 1000LB Tie down Device (H1) Extent of Header Single Portal Frame (One Braced Wall Panel) Extent of Header Double Portal Frame (Two Braced Wall Panels) Ma x H e i g h t 1 0 ' - 0 " Alternate Braced Wall Panel Garage Portal Design PFH Figure R602.10.6.2 Min. 3"x11 1/4" net header (Steel header prohibited) Ma x T o t a l W a l l H e i g h t 1 2 ' - 0 " Table R602.10.5 MIN. LENGTH OF BRACED WALL PANELS Min. reinforcing of foundation, (1) #4 bar top & bottom of footing. Lap bars 15" min. Min. Footing under opening is 12"x12" 2'-18" finished width for single or double portal Wall height 8ft 9ft 10ft 11ft 12ft 16" 18" 20" 22"* 24"*CS - P F Pony Wall Height Tension Strap per Table 602.10.6.4 (On opposite side of Sheathing) Fasten Top Plate to header w/2 Rows of 16d sinker nails at 3" O.C. TYP Min.3_ 8" Wood Structural Panel Sheating MIN. WIDTHS AND TIE-DOWN FORCES OF ALTERNATE BRACED WALL PANELS Table R602.10.6.1 Seismic Design Category and Windspeed Tie-Down Force (lb.) 8 ft. 2'-4" 9 ft. 2'-8" 10 ft. 2'-8" 11 ft. 3'-2" 12 ft. 3'-6" SDC A,B, and C Windspeed <110 MPH R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 1800 3000 1800 3000 2000 3300 2200 3600 SDC D,D, and D Windspeed <110 MPH R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 1800 3000 1800 3000 - - 0 1 2 2'-8" 2'-8" 2'-8" Note a Note a - - Height of Braced Wall Panel Sheathed Width Sheathed Width Table R602.10.5 MIN. LENGTH OF BRACED WALL PANELS Wall height 8ft 9ft 10ft 11ft 12ft 16" 16" 16" 18* 20*PF H *=10' is the max wall height allowed but a pony wall attached up to 12' *=10' is the max wall height allowed but a pony wall attached up to 12' Min. (2)1_ 2" Dia. Anchor Bolts installed per R403.1.6 with 2"x2"x3__ 16" Plate Washers All information remains the same except the Tie Down Anchor Bolt and single plate for CS-PF (Same on both sides of opening) Alternate Braced Wall Panel Garage Portal Design CS-PF Figure R602.10.6.4 (1) #4 Rebar Horiz. Cont. Gravel Undisturbed Soil Wood Foundation Heated Room Garage Mono Pour for Inside Garage 2' - 6 " 10"1' - 4 " Brick Detail at Garage THRU JOIST & POST P O S T C A P P E R P L A N P .T . D E C K J O I S T P E R P L A N CARRAGE BOLTS 2X P.T. (2) 1/2"x5 1/2" AN CONNECTION PER PLAN P.T. BLOCKING PER PLAN P.T. BEAM P.T. POST OR WALL 2X6 P.T. TOP RAIL @ 5 3/8"O.C. 2X2 P.T. PICKETS 1X4 P.T. EACH SIDE 4 X 4 P .T . P O S T 2 X 4 P .T . S P A C E D D E C K I N G36 " M I N . 4" MA X . INTO RIM JST. @ 16" O.C. THROUGH P.T. LEDGER 5/8"x5" LAG SCREWS 1 X 4 P .T . E A C H S I D E (2) #4 Rebar Horiz. Cont. 8" 4' Concrete Slab Concrete Slab Concrete Slab Perimeter Slab Insulation Detail (2) #4 Rebar Horiz. Cont. Concrete Slab Rigid Insulation Flashing R-10 Insulation 11" Min Run on Conc. Step into house Max Rise 7 3/4" Concrete Steps into House OR Deck Detail (USE IF APPLICABLE) (USE IF APPLICABLE) (USE IF APPLICABLE)(USE IF APPLICABLE) (USE IF APPLICABLE) 2' - 6 " 8"1' - 4 " Rock Detail at Garage (USE IF APPLICABLE) Nailing or Screws 7" O.C. Max Horiz. & Vert. Blocks at Drywall Joints for 7" O.C. Screws of Nails Drywall is shown cutaway Overlapped Double Plate 2x6 Exterior wall @16"O.C. with 7/16" Waferboar d Drywall & Waterboard not Shown for clarity2x4 Interior Wall @16" O.C. 4'x8' Shear Panel on Both Sides 4 ' 8'x8' Shear Panel on Single Side IBWP 3 Interior Braced Wall Panel IBWP 2018 IRC Section 602.10.1 BWP 3-Interior Braced Wall Method 3 (IRC R602.10) 2x4 Studs @ 16" O.C. w/7/16" OSB Nailed 5" O.C. and 10" Field IBWP 5-Interior Braced Wall Method 5 1/2" min. Gypsum board 48" length applied to both sides OR 96" to one side covering 3 studs spaced 16" or 2 studs spaced 24" apart, blocked Screwed @7"/7" w/1" Drywall Screws All Vert Joints occur over stud All Hori. Joints blocked w/2x4 blocking Braced Wall Panel BWP 3' Braced Walls at each strap with 7/16" OSB one side, blocked in all joints Nailed @ 6"/12" w/ 8d or Stapled @ 4"/8" w 16 ga. All joints must occur over raming member 6" at edge 12" in field 8d @ 12" O.C. in field 8d Nails @ 6" O.C. @ edge Braced Wall Panel Detail BWP IBWP 5 All exterior wall are braced walls. 48 . 5 " t o c n t r 4 ' - 0 " 3 ' - 1 1 1 /2 " 4' - 0" Su n d a n c e dr a f t i n g & de s i g n 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 NNNN EE D EE D EE D EE D AH AHAHAH OU S E OU S E OU S E OU S E PPPP LA N . C O M LA N . C O M LA N . C O M LA N . C O M PAGE LAYOUT GN-General Notes & Codes A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan TO T A L S Q . F T G . = 5 3 5 5 MA I N F L O O R = 2 6 8 5 / 2 4 3 4 I N T E R I O R BA S E M E N T = 2 6 7 0 / 2 3 7 6 I N T E R I O R GA R A G E = 1 0 2 1 Start Date Bid Set Drawn by: Reviewed by: Co p y r i g h t S u n d a n c e D r a f t i n g a n d D e s i g n 2 0 2 2 Sheet: Scale: D Size Paper B Size Paper of A5 Rev. Permit Set Rev. 04-26-2021 Mu i r Jo e & B a r b R e s i d e n c e Rev. 01-21-2022 02-16-2022 GN T. Stoddart 1/8"=1'-0" UNO 1/4"=1'-0" UNO A. Serrano Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout 3' Hallway Clearance 2018 IRC, Section R106 and R311.6 Saftey Glazing 2018 IRC, Sections R106 and R308.4.5 Header Notes:Header Notes:Header Notes:Header Notes: Width x Height (ex. 3050 is 3'0" wide by 5'0" Tall) Door same SH-is Single Hung DH is Double Hung SV is Side Vent F is Fixed or Picture T or Temp is Tempered Safety Glass Tra is Transom OBS Obscured Window Callouts:Window Callouts:Window Callouts:Window Callouts: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Exhaust and Ventilation:Exhaust and Ventilation:Exhaust and Ventilation:Exhaust and Ventilation: 2018 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms Smoke Alarms:Smoke Alarms:Smoke Alarms:Smoke Alarms:S 2018 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly Carbon Monoxide Alarms:Carbon Monoxide Alarms:Carbon Monoxide Alarms:Carbon Monoxide Alarms:CM Location of furnace and water heater 2018 IRC, Section R106, and M1305 Elevate all sources of ignition in the garage a min. of 18" above the floor 2018 IRC, Sections R106, and M1307.3 Provide a protection post in the garage to prevent vehicle damage to furnace and water heater. 2018 IRC, Section R106, M1307.3.1 Furnace:Furnace:Furnace:Furnace: Alternate Braced Wall Panel Garage Portal Design CS-PF See Figure R602.10.6.4 on Sheet A4 Garage Portals:Garage Portals:Garage Portals:Garage Portals:CS-PF Alternate Braced Wall Panel Garage Portal Design PFH See Figure R602.10.6.2 on Sheet A4 Garage Portals:Garage Portals:Garage Portals:Garage Portals:PFH The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. Ventilation R408.1Ventilation R408.1Ventilation R408.1Ventilation R408.1 Through Floor min 18"x24" or through perimeter wall min 16"x24" required crawl space opening. If applicable, refer to mechanical code for access requirements where mechanical equipment is located under floors. 2018 IRC, Section R106, R408.4 M1305.1.4 Crawl Space:Crawl Space:Crawl Space:Crawl Space: (*USE IN SEISMIC D ZONE-BONNEVILLE COUNTY) 2x6 Treated Sill Plate over Foam Sill Sealer with 1/2" Anchor Bolts @ 72" (*32") O.C. 10" Long, 7" Embedded Max. 12" from all Corners or Splices Concrete Wall Greater than 9' need to have an Architects or Engineer Seal 8' & under (1) Horiz. Bar in top 12" and one at mid-height 8'-1" to 9' (1) Horiz. Bar in top 12" & one bar at each third point Min. (2) Anchor Bolts per Sill Plate w/ nut & ROUND plate Washer 2 1/2 ∅ x1/4" Min. For each Bolt (*3"x3"x1/4" SQUARE) over Concrete Foundation wall Consistent w/ 2018 IRC R401-403 With Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/ 2018 IRC Section R106.1 over Undisturbed Soil Foundation Wall System:Foundation Wall System:Foundation Wall System:Foundation Wall System:G 2018 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. One egress ladder shall be provided within a window well of an unfinished basement Window Well System:Window Well System:Window Well System:Window Well System:J 2018 IRC Code Section R402.1.1 Fastner for Preservative treated wood shall be of hot dipped zinc- coated galvanized steel, stainless steel, silicon bronze or copper. Exceptions: 1. One-half inch (12.7mm) diameter or greater steel bolts. 2. Fasteners other than nail & timber rivets shall be permitted to be of mechanical deposited zinc coated steel with coating weights in accordance with ASTM B695 class 55 min. Fasteners for Preservative Fasteners for Preservative Fasteners for Preservative Fasteners for Preservative Treated WoodTreated WoodTreated WoodTreated Wood Except where otherwise protected from frost, foundation walls, piers and other permanent supports of buildings and structures shall be protected from frost by one or more of the following methods: 1. Extended below the frost line specified in Table R301.2 2. Construct in accordance with Section 403.3 3. Construct in accordance with ASCE 32 or 4. Erected on Solid Rock Exceptions: -Protection of freestanding accessory structures with an area of 400 of 600 square feet or less, of light frame construction with an eve height of 10' of less shall not be required. -Decks not supported by a dwelling need not be provided with footings that extend below the frost line. -Footings shall not bear on frozen soil unless the frozen condition is permanent. Frost Protection 403.1.4.1Frost Protection 403.1.4.1Frost Protection 403.1.4.1Frost Protection 403.1.4.1 GENERAL STRUCTURAL NOTES A. CODES AND SPECIFICATIONS 1. International Building Code (IRC) - 2012 Edition 2. ACI 318-11 Building Code Requirements for Reinforced Concrete 3. ANSI/AF&PA National Design Specifications (NDS) & Suppl. for Wood Const. -2012 Edition 4. ASCE 7-10 Min. Design Loads for Buildings and other Structures B DESIGN LOADS UNIFORM (PSF) 1. Floor Loads Uniform a. Deck Live = 100 C MATERIALS 1. Dimensional Lumber #2 Douglas Fir 2. Concrete fc Slab 4000 PSi 3. Reinforcing Steel ASTM A615 - Grade 60 4. Anchor Bolts A36/F1554 GRADE 36 4" Concrete Desk Table Span 4'-0" 6'-0" 8'-0" Joist Size 2x4 2x6 2x8 Joist Spacing 16" O.C. 16" O.C. 16" O.C. SDS 1/4 x 3 1/2 Screw Spacing 8" O.C. 5" O.C. 4" O.C. 6" Concrete Desk Table Span 4'-0" 6'-0" 8'-0" Joist Size 2x4 2x6 2x8 Joist Spacing 16" O.C. 16" O.C. 12" O.C. SDS 1/4 x 3 1/2 Screw Spacing 7" O.C. 4 1/2" O.C. 3" O.C. REQUIRED BY CITY OF AMMON (If Applicable) IBWP 5-Interior Braced Wall Method 5 IBWP 5(Length?) 1/2" min. Gypsum See plan for length 2 studs spaced 24" apart, blocked Screwed @7"/7" w/1" Drywall Screws All Vert Joints occur over stud All Hori. Joints blocked w/2x4 blocking Above each IBWP3 a 2x4 Truss block is required as well at each corner, not over window ALL EXTERIOR WALLS ARE BRACED WALLS APA Simplified Wall BracingAPA Simplified Wall BracingAPA Simplified Wall BracingAPA Simplified Wall Bracing These Plans follow the 2018 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. We will have email confirmation at the end of permit stage-finals that the client/contractor has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct. General Notes:General Notes:General Notes:General Notes: Copyright Sundance Drafting & Design 2021 All Right Reserved General Notes & 2018 IRC Codes Sundance drafting & design 208.524.2880208.524.2880208.524.2880208.524.2880 NNNN EEDEEDEEDEED AHAHAHAH OUSEOUSEOUSEOUSE PPPP LAN.COMLAN.COMLAN.COMLAN.COMMuir Residence 8 12 8 12 8 12 11 ' - 0 " 8 12 8 12 8 12 9' - 0 " 9' - 0 " Rock Vertical Siding Asphalt Shingles 8 12 8 12 Stucco Shakes 8 12 Su n d a n c e dr a f t i n g & de s i g n 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 NNNN EE D EE D EE D EE D AH AHAHAH OU S E OU S E OU S E OU S E PPPP LA N . C O M LA N . C O M LA N . C O M LA N . C O M PAGE LAYOUT GN-General Notes & Codes A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan TO T A L S Q . F T G . = 5 3 5 5 MA I N F L O O R = 2 6 8 5 / 2 4 3 4 I N T E R I O R BA S E M E N T = 2 6 7 0 / 2 3 7 6 I N T E R I O R GA R A G E = 1 0 2 1 Start Date Bid Set Drawn by: Reviewed by: Co p y r i g h t S u n d a n c e D r a f t i n g a n d D e s i g n 2 0 2 2 Sheet: Scale: D Size Paper B Size Paper of A5 Rev. Permit Set Rev. 04-26-2021 Mu i r Jo e & B a r b R e s i d e n c e Rev. 01-21-2022 02-16-2022 A1 T. Stoddart 1/8"=1'-0" UNO 1/4"=1'-0" UNO A. Serrano 8:12 Roof Pitch 9' & 11'-Main Walls 9'-Basement Walls 30" Min. Frost Depth Footing Garage to Match TYP Front Elevation Left Elevation Back Elevation Right Elevation Scale: 1/8" & 1/16"=1'-0" on 17" x 11" Paper Scale: 1/4" & 1/8" =1'-0" on 36" x 24" Paper Foundation Permit Set DW Cut 18' for Garage Door opening with Req. Blocking Cut 9' for Garage Door opening with Req. Blocking 9' - 6 " 1 2' - 1 0 " 1 4' - 0 " 4' - 9 1 /2 " 16 ' - 7 " 27 ' - 6 " 13 ' - 0 " 13 ' - 8 " 13 ' - 1 0 " 6' - 4 " 6' - 8 " 14' - 8 1/2"8' - 11"9' - 3 1/2"14' - 4"21' - 7"20' - 0" 7' - 7 " 4' - 0 " 2' - 4 " 6' - 2 1 / 2 " 3' - 8 " 8' - 7 " 5' - 7 " 5' - 6 " 7' - 1 0 " 10 ' - 7 " 9' - 5 " 16 ' - 7 "Bath50 CFMBedroom 3 15'-5" x 14'-0" 10 CFM Fresh Air Smoke Detector Family Room 43'-9" x 18'-11" 10 CFM Fresh Air Storage Mech. 3' Clearance in front of Furnace Seismic Straps around WH Cut 3' for Passage Opening with Req. Blocking Cold Storage 3068 Bedroom 4 16'-8" x 11'-10" 10 CFM Fresh Air Smoke Detector Deck Above 5040-SV 4030-SV 2' - 4 " 12 ' - 8 " 12' - 11 " 10' - 9" 5' - 2" 3068 6x6 Post 16x16x8 Footer TYP.Desk5040-SV 4040-SV 4040-SV 4040-SV J J2x6 Wall2' - 0 " 5' - 0 " 3' - 8 " 4' - 0 " 1 6' - 1 0 "266826682668Bedroom 5 18'-5" x 11'-10" 10 CFM Fresh Air Smoke Detector2468 2468 24682468De s k 3' - 5 " 2468 WIC WIC WIC24682468 24682' - 6 "LNFloating Staircase Kitchenette 12'-0" x 9'-4" 100 CFM Fresh Air Beam Sized By Others 9' - 6 " 3' - 0 " 3' - 0"6' - 6 1/2"3' - 0"4' - 4 1/2"12' - 1 1/2"12' - 1 1/2"12' - 1 1/2"12' - 1 1/2" 6' - 6 " 2 8' - 1 0 " 14' - 0"7' - 7" 27 ' - 1 0 " 7' - 3"9' - 0"4' - 1"23' - 6"5' - 7"7' - 0"5' - 10" 10 ' - 6 " 2' - 7 " 9' Basement F. Walls 3' - 1 0 " 7' - 9 1 / 2 " 5' - 8 1/2"7' - 1"10' - 0"27' - 9" 1 2' - 4 " 8' - 0 " 1' - 9" 2' - 4" 1 0' - 8 "LN2-2668-Gls 6' - 6 " 1 4' - 1 " 9' - 6 1 / 2 " 6' - 9 1 / 2 " 18' - 5"2' - 0"7' - 4"2' - 0"16' - 3"27' - 7" 3' - 8"3' - 8" 2' - 0 " 2' - 0 " 7' - 8 " 20 ' - 2 " Center of Footing 15' - 7" 50 CFM 50 CFM 5' - 4 " 7' - 4 " 1' - 4 " 3' - 1 1 " 5' - 0 " 3' - 1 1 " 1' - 0 " 8' - 6 " 6' - 6 " 6' - 1 0 " 1 2' - 2 " 8' - 6 " 7' - 3 " 9 " 7' - 2 " 7' - 4 " 5' - 4 " 5' - 1" 11 ' - 7 " 3' - 5 " Center of BeamBeam Sized By Others Furnace WHWS Duct Chase 7' - 1" 6' - 1 0 " Fl o o r J o i s t D i r e c t i o n Fl o o r J o i s t D i r e c t i o nFloor Joist DirectionFloor Joist DirectionFloor Joist Direction16 15 14 13 12 Up Beam Sized By Others 16x16x8 Footer or Similar 2' - 6" 1' - 10" 6' - 4" 1' - 10" 3' - 1" 10' - 2" 8' - 6 " 7' - 2" (See GN for Detail) TRIPLE CAR GARAGE 4" CONCRETE SLAB SLOPE CONC. FLOOR TO DRAIN TO GARAGE DOOR H1 SIMPSON STRONG TIE STHD14-INSTALLED & NAILED AS PER MANUFACTURERS RECOMMENDATIONS CONCRETE TO WOOD CONNECTION HOLDDOWN: 15 ' - 0 " (10)16x16x8 Footer or Similar 16 ' - 4 1 / 2 " 50 CFM 1 3 5 ° 135° 2' - 1 0 "2' - 1 0" Su n d a n c e dr a f t i n g & de s i g n 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 NNNN EE D EE D EE D EE D AH AHAHAH OU S E OU S E OU S E OU S E PPPP LA N . C O M LA N . C O M LA N . C O M LA N . C O M PAGE LAYOUT GN-General Notes & Codes A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan TO T A L S Q . F T G . = 5 3 5 5 MA I N F L O O R = 2 6 8 5 / 2 4 3 4 I N T E R I O R BA S E M E N T = 2 6 7 0 / 2 3 7 6 I N T E R I O R GA R A G E = 1 0 2 1 Start Date Bid Set Drawn by: Reviewed by: Co p y r i g h t S u n d a n c e D r a f t i n g a n d D e s i g n 2 0 2 2 Sheet: Scale: D Size Paper B Size Paper of A5 Rev. Permit Set Rev. 04-26-2021 Mu i r Jo e & B a r b R e s i d e n c e Rev. 01-21-2022 02-16-2022 A2 T. Stoddart 1/8"=1'-0" UNO 1/4"=1'-0" UNO A. Serrano 1/4"=1'-0" UNO D Size Sheet 1/8"=1'-0" UNO B Size Sheet 1/4"=1'-0" UNO D Size Sheet Foundation 9' & 11'-Main Walls 9'-Basement Walls 30" Min. Frost Depth Footing Garage to Match TYP Permit Set W D 15' - 7"7' - 2"10' - 2"14' - 4"21' - 5"20' - 0" 10 ' - 6 " 8' - 6 " 5' - 7 " 5' - 6 " 4' - 3 " 9' - 6 " 1 2' - 1 0 " 1 4' - 0 " 6' - 6" 20' - 5"9' - 4"16' - 3" 3080 6' - 0" 3' - 6" 8' - 1" 4' - 9" 6' - 6" 3080-w/-18"-SLS 3' - 0"3' - 0"2' - 6" 3080 13 ' - 3 " 2' - 8 " 5' - 0 " 1' - 4 " 2-2668Stacked W/D6060-F 3' - 2" 3' - 9" 3' - 9" 3' - 5" 73' - 5" 2-2680-Gls 3' - 7"3' - 7"5' - 8"4' - 6"4' - 2"3' - 0"3' - 0"4' - 2"7' - 5"3' - 0"3' - 0"8' - 0"10' - 0"10' - 0" 4040-SV 3 Car Garage 1014 Square Feet 7' - 1"13' - 3"23' - 4" 8' HH 3' - 1"5' - 0"5' - 0"5' - 4" 5080-Op 5080-Op 90 6 8 - O p Bath 50 CFM Bedroom 2 12'-6" x 12'-4" 10 CFM Fresh Air 9' Flat Ceiling Smoke Detector Entry 11' Ceiling Family Room 21'-0" x 12'-2" 10 CFM Fresh Air 11' Coffered Ceiling Dining Room 11'-10" x 14'-6" 10 CFM Fresh Air 9' Flat Ceiling Kitchen 14'-6" x 14'-0" 100 CFM Fresh Air 9' Flat Ceiling Living Room 14'-0" x 14'-4" 10 CFM Fresh Air 11' Flat Ceiling Master Bath 50 CFM Master Bedroom/1 13'-8" x 17'-11" 10 CFM Fresh Air 9' Flat Ceiling w/ Box Tray Smoke Detector Office 13'-0" x 12'-6" 10 CFM Fresh Air 9' Flat Ceiling Pantry Utility 50 CFM 80 WHF WIC Deck Hall 11' Ceiling 18 x 9 - O H - G a r a g e - D o o r 2' - 6 " 13 ' - 0 " 27 ' - 4 " 16 ' - 7 " 9x 9 - O H - G a r a g e - D o o r 30 6 8 30 8 0 30 8 0 4' - 8 " 18 ' - 0 " 4' - 8 " 2' - 0 " 9' - 0 " 2' - 0 " 6' - 1 1 " 5' - 8 " 15 ' - 3 " 3080-Op 3' - 6 " 3' - 0 " 3' - 6 " 2' - 0 " 11' - 10"9' - 0"3' - 6"2' - 0" 30 8 0 Built Ins 3' - 1 1 " 8' - 1 1 " 8' HH REF2-2680-Gls2050-F30804060-F 4060-F 4060-F 8' HH 8' HH 2x6 Wall 5060-F2060-F2' - 6" 1' - 10" 6' - 4" 1' - 10" 3' - 1" 3' - 2"3' - 2" 5016-Tra2016-Tra3046-Case2046-F 2046-F 5050-F 2050-F 2050-F 3' - 0"7' - 0"3' - 0"3' - 11"48' - 11 1/2" (2 TYP) 8x8 Post w/ Stone Wrap Dn 2' - 6 " 12 ' - 6 " 3' - 5 " 4' - 9 " 6' - 9 1 / 2 " 14' - 1" 10 ' - 5 " 13 ' - 5 " 14' - 0" 27 ' - 1 0 "2x6 WallDO DW 2' - 0 " 3' - 8"3' - 8" 1' - 1 0 "3080-Op8' - 0 "306824682-2468T 2040-SHT 2040-SH3' - 3" 3' - 3"3050-SV2060-F2016-Tra4020-F2-30803060-SH 3060-SH3060-SH2' - 0 " 13 ' - 5 " 7' - 4 1 / 2 " 11 ' - 6 1 / 2 " 5' - 0" 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 Bu i l t I n s 5' - 0 " 7' - 9 " 6' - 3 " 6' - 6" 28' - 10 "2046-F3046-Case2046-FOC G a s F P 15 ' - 0 " Solar Tube Solar Tube Solar Tube 3' - 0 " 4' - 1 0 " 4' - 1 1 / 2 " 5' - 10" 3' - 0 " 9' - 6 " 4' - 3 " 4' - 3"2680Bath50 CFM3080-Op3080-P5' - 1 " 1' - 1 0 " 11 " M i n . 1' - 5" 5' - 0" 3' - 2" 12' - 10 " 5' - 11" 7' - 10" 10' - 10 " 4' - 5 " 3' - 6 " 6' - 0 " 7' - 1 0 " 14' - 7"2x6 Wall7' - 3" 2' - 4" 2' - 6 " 3' - 8 1 /2" 4' - 1 1 /2" 4' - 1 1 /2" 3' - 3 1/ 2" 14' - 11 1 / 2 " 2' - 8 " 4' - 0 " 3' - 2" 6' - 4" 4' - 4" 8' - 6" 2' - 5" 14' - 7" 19' - 4" 5' - 1"1' - 8"4' - 4"3' - 8"9' - 9" 2' - 7 " 8' - 11"9' - 3 1/2" 10 1/2" 8' - 6"4' - 2"3' - 10 1/2" 1' - 0" 1' - 3 1/2" 3' - 6"9' - 2"3' - 0"11' - 7" 15 ' - 7 " 5' - 2 " Contractor to locate exact location of req'd 22" x 30" Attic Access Point Min. 30" Vert. Head Room Clearance (2009-R807.1)20 m i n F i r e R a t e d 1- 3 / 8 " S o l i d D o o r or E q u a l , S e l f C l o s e S CM S CM 8' HH 8' HH 8' HH 8' HH8' HH8' HH8' HH8' HH8' HH8' HH8' HH8' HH8' HH8' HH8' HH2060-F8' HH2060-F1' - 7 " 1' - 3 " 1' - 3" 1' - 7" 8' HH 6616-Tra 12' - 10 " 3' - 0" 3' - 0" 6' - 8 1/ 2" 3' - 3 1/ 2" Duct Chase 9' C e i l i n g 11 ' C e i l i n g OC G a s F P 11' Ceiling Covered Porch 11' Cap Su n d a n c e dr a f t i n g & de s i g n 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 NNNN EE D EE D EE D EE D AH AHAHAH OU S E OU S E OU S E OU S E PPPP LA N . C O M LA N . C O M LA N . C O M LA N . C O M PAGE LAYOUT GN-General Notes & Codes A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan TO T A L S Q . F T G . = 5 3 5 5 MA I N F L O O R = 2 6 8 5 / 2 4 3 4 I N T E R I O R BA S E M E N T = 2 6 7 0 / 2 3 7 6 I N T E R I O R GA R A G E = 1 0 2 1 Start Date Bid Set Drawn by: Reviewed by: Co p y r i g h t S u n d a n c e D r a f t i n g a n d D e s i g n 2 0 2 2 Sheet: Scale: D Size Paper B Size Paper of A5 Rev. Permit Set Rev. 04-26-2021 Mu i r Jo e & B a r b R e s i d e n c e Rev. 01-21-2022 02-16-2022 A3 T. Stoddart 1/8"=1'-0" UNO 1/4"=1'-0" UNO A. Serrano 1/4"=1'-0" UNO D Size Sheet 1/8"=1'-0" UNO B Size Sheet 1/4"=1'-0" UNO D Size Sheet Main Floor 9' & 11'-Main Walls 9'-Basement Walls 30" Min. Frost Depth Footing Garage to Match TYP Permit Set 11" Min Run on Conc. Step into house Max Rise 7 3/4" Concrete Steps into House 3' - 0 " 6' - 8 " H a n d r a il H e i g h t H e a d r o o m H e i g h t 7 1 / 2 " 10 1/2" Great Room Entry Stair Well Family Room Coffered Ceiling Beam Sized By Others A 8 12 B C D E G (2) #4 Rebar Horiz. Cont. (2) #4 Rebar Horiz. Cont. Deck 11 ' - 8 " 11 ' - 0 " 1' - 2 " 9' - 0 " 8" 22 ' - 8 " 23 ' - 1 0 " 32 ' - 1 0 " 33 ' - 6 " 9' - 0 " 2' - 6 " 9' - 0 " Su n d a n c e dr a f t i n g & de s i g n 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 NNNN EE D EE D EE D EE D AH AHAHAH OU S E OU S E OU S E OU S E PPPP LA N . C O M LA N . C O M LA N . C O M LA N . C O M PAGE LAYOUT GN-General Notes & Codes A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan TO T A L S Q . F T G . = 5 3 5 5 MA I N F L O O R = 2 6 8 5 / 2 4 3 4 I N T E R I O R BA S E M E N T = 2 6 7 0 / 2 3 7 6 I N T E R I O R GA R A G E = 1 0 2 1 Start Date Bid Set Drawn by: Reviewed by: Co p y r i g h t S u n d a n c e D r a f t i n g a n d D e s i g n 2 0 2 2 Sheet: Scale: D Size Paper B Size Paper of A5 Rev. Permit Set Rev. 04-26-2021 Mu i r Jo e & B a r b R e s i d e n c e Rev. 01-21-2022 02-16-2022 A4 T. Stoddart 1/8"=1'-0" UNO 1/4"=1'-0" UNO A. Serrano Alternate Reinforcing Bar Size and Spacing Vertical Rebar Only 8" nominal wall thickness 72" Max rebar spacing #4 @ 15" is equal to #5 @ 23" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 36" Table R403.1 Min. Width of Conc. or Masonry Footings (inches) Load-Bearing Value of Soil (psf) 1500 2000 3000 Conventional Light-frame Construction 1-story 12 12 12 2-story 15 12 12 3-story 23 17 12 4" Brick Veneer over light frame 1-story 12 12 12 2-story 21 16 12 3-story 32 24 16 Table R404.1.2 (3) Reinforced Concrete Foundation Walls GM, GC, SM, SM-SC and ML Soils 45 Min. Vertical Reiforcement Size & Spacing Max. Wall Height 8' 9' Max. Unbalanced Backfill Height 5' or less 6' 7' 5' or less 6' 7' 8' 8" Conc. Walls Not Required Not Required #6 at 36" O.C. Not Required Not Required #6 at 35" O.C. #6 at 32" O.C. Concrete Wall Greater than 9' need to have an Architects or Engineers Seal 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8'-1" to 9' (1) Horizontal Rebar in top 12" and one bar at each third point U s e t h i s t a b l e u n l e s s a s o il t e s t i s d o n e 1/4"=1'-0" UNO D Size Sheet 1/8"=1'-0" UNO B Size Sheet 2018 IRC Code Section R801, R901 Architectural Grade, 25 year Asphalt Shingles R905 over #15 building felt over 7/16" Ext. OSB roof sheeting w/Clips & nailed 6" O.C.-Edges, 10" O.C.-field over 5:12 Pitch Engineered Trusses @ 24" O.C. (Framed According to Engineered Truss Layout) with R-49 Blown in Attic Insulation with 5/8" Sheet Rock on Interior Side Taped Prep'd for Interior Finishes Contractor to indicate 22"x30" Attic Access Location 2018 IRC Ice Protection Ice Barrier consisting of 2 layers of cemented under-layment and extend from the eave's edge 24" min. from inside exterior wall Roof System:Roof System:Roof System:Roof System: 2018 IRC Code 2x6 Fascia Board with style "D" Metal Drip Edge with 3/8" Soffit Sheeting with 3" Continuous Soffit Venting with add'l 2x4 Support as Required Soffit System:Soffit System:Soffit System:Soffit System: R404.1 Foundation Walls & R611 Exterior Concrete Walls 6" & 8" Concrete wall w/ 2 1/2" Insulation Both Sides Exterior Walls:Exterior Walls:Exterior Walls:Exterior Walls: 2018 IRC Code 2x4 Stud framed @ 24" O.C. with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with 1/2" Sheetrock Both Sides Taped Prep'd for Interior Finishes Interior Walls:Interior Walls:Interior Walls:Interior Walls: 2018 IRC Code Section R502, R503, R504 3/4" T&G OSB Sub-floor Glued & Nailed over 11-7/8 TJI Engineered Floor Joist Series, Placement, & O.C. Spacing as determined & indicated on TJXpert Layout. (Version 6.0 or later) connected to Rim Joist, spliced using gal. metal ties not less than .058" x 1.5" wide fastened w/6 16d nails ea. side over 1/2" Sheetrock on Ceiling Side Taped and Prep'd for Interior Finishes Floor System:Floor System:Floor System:Floor System: (*USE IN SEISMIC D ZONE-BONNEVILLE COUNTY) 2x6 Treated Sill Plate over Foam Sill Sealer with 1/2" Anchor Bolts @ 72" (*32") O.C. 10" Long, 7" Embedded Max. 12" from all Corners or Splices Concrete Wall Greater than 9' need to have an Architects or Engineer Seal 8' & under (1) Horiz. Bar in top 12" and one at mid-height 8'-1" to 9' (1) Horiz. Bar in top 12" & one bar at each third point Min. (2) Anchor Bolts per Sill Plate w/ nut & ROUND plate Washer 2 1/2 ∅ x1/4" Min. For each Bolt (*3"x3"x1/4" SQUARE) over Concrete Foundation wall Consistent w/ 2018 IRC R401-403 With Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/ 2018 IRC Section R106.1 over Undisturbed Soil Foundation Wall System:Foundation Wall System:Foundation Wall System:Foundation Wall System: 2018 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. One egress ladder shall be provided within a window well of an unfinished basement Window Well System:Window Well System:Window Well System:Window Well System: A B C D E G J Cross Section Permit Set 2018 IRC R302.7, 311.7.2, R311.7 R312.1.3 Eq. Stair Risers 7 3/4" Max. height, Eq. Stair Treads 10" Min. depth over (3) 11.5" MIN. Stair Stringers bolted at bottom with P.T. 2x4 -3 places with 3" x 1/2" ∅ bolt and top securely mounted to framing with Simpson A35 Connector at Stairs Stringer to Ledger or alternate approved connection. with Cont. Handrail System mounted 36"above stair plane. with Handrail return to wall. with a Min. 6'-8" Head Clearance above stair plane. with all other Railing System to be min. 42" above FFL & meet current building codes for vert. and horiz. loading. Slate Spacing to no more than 4" sphere to pass thru. 1/2" Gypsum Board under stairs 2% Slope Max 1 to 48 Stair System:Stair System:Stair System:Stair System:H 16' - 9"27' - 5"13' - 0"2' - 5" 45' - 7 1/2"59' - 7"255' - 7 1/2" 20 ' - 6 " 14 ' - 8 1 / 2 " 8' - 1 1 " 9' - 3 1 / 2 " 14 ' - 4 " 21 ' - 7 " 20 ' - 0 " 70 ' - 7 " 10 9 ' - 4 " 70 ' - 7 " 7' - 11"5' - 7"20' - 4 1/2"25' - 8 1/2" 255' - 7 1/2"59' - 7"59' - 0"2' - 3 " 9' - 1 " 14 ' - 6 " 9' - 1 1 1 / 2 " 46 ' - 0 " 27 ' - 7 " 70 ' - 7 " 10 9 ' - 4 " 70 ' - 7 " 18 ' - 5 " 2' - 0 " 7' - 4 " 2' - 0 " 16 ' - 3 " 15' - 0"27' - 10"2' - 0" 10' - 6" 15 ' - 7 " 7' - 2 " 10 ' - 2 " 8' - 6"2' - 7" 5' - 7"5' - 6" 1 2 4 ' - 6 " 124' - 6" 30 ' - 0 " 30 ' - 0 " 5 0 ' - 0 " R u s t l e r ' s T r a i l 80' - 0" 1 2 0 ' - 2 " 5 9 ' - 7 1 /2 " 75' - 2 1/2" 1 0 8' - 6" 6' - 6 " 6' - 6 " Line of Required Setbacks Line of Required Setbacks 352.90' S 61° 41' 56" E 25 0 . 4 9 ' N 2 8 ° 1 8 ' 0 4 " E 397.62' N 61° 41' 56" W 4 1 . 3 5 ' S 0 8 ° 0 7 ' 5 5 " W R =2 30 .00 ' L =5 5 .0 4 ' 1 5 9 . 1 1 ' S 2 1 ° 5 2 ' 3 7 " W 265' - 2 1/2" Su n d a n c e dr a f t i n g & de s i g n 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 20 8 . 5 2 4 . 2 8 8 0 NNNN EE D EE D EE D EE D AH AHAHAH OU S E OU S E OU S E OU S E PPPP LA N . C O M LA N . C O M LA N . C O M LA N . C O M PAGE LAYOUT GN-General Notes & Codes A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan TO T A L S Q . F T G . = 5 3 5 5 MA I N F L O O R = 2 6 8 5 / 2 4 3 4 I N T E R I O R BA S E M E N T = 2 6 7 0 / 2 3 7 6 I N T E R I O R GA R A G E = 1 0 2 1 Start Date Bid Set Drawn by: Reviewed by: Co p y r i g h t S u n d a n c e D r a f t i n g a n d D e s i g n 2 0 2 2 Sheet: Scale: D Size Paper B Size Paper of A5 Rev. Permit Set Rev. 04-26-2021 Mu i r Jo e & B a r b R e s i d e n c e Rev. 01-21-2022 02-16-2022 A5 T. Stoddart 1/8"=1'-0" UNO 1/4"=1'-0" UNO A. Serrano Rustler Hideout Subdivision Div. 1, Block 1, Lot 6 Madison County, Idaho N O R T H Plot Plan Pe r m i t S e t 1/4"=1'-0" UNO D Size Sheet 1/32"=1'-0" UNO B Size Sheet 1/16"=1'-0" UNO D Size Sheet