Loading...
HomeMy WebLinkAboutREVIEW SUMMARY RESPONSE - 22-00372 - Thomson Farms the Grove - ClubhouseAuthor Name Author Email Author Phone No.: Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Alex Owens Alex.Owens@rexburg.org 208-372-2330 Cody Jones Cody.Jones@rexburg.org 208-372-2173 Don Allen Don.Allen@rexburg.org 208-372-2174 Description : Thomson Farms the Grove - Clubhouse Address : 397 Thomson Farms Rd Application Type : Document Filename : ! Thomson Farms Clubhouse - PERMIT SET - 2018.08.15.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments A0.0 Free text Cody Jones : Building Open 1 Will need engineered truss package reviewed and acknowledged by building design professional as soon as possible. A0.0 Free text Cody Jones : Building Open 1 Exit lighting and exit signs to comply with section 1008 and 1013. Need Envelope COMM check or prescriptive insulation form signed. Cross slope of sidewalks and landings not to exceed 2%. All Concealed paces will need fire blocked and draft stopping installed. A0.0 Free text Cody Jones : Building Open 1 Total occupant load? 120? A0.3 Free text Cody Jones : Building Open 4 Windows within a 24" radius from edge of door needs to be tempered. All Glass and Glazing needs to meet requirements of Chapter 24. S101 Free text Cody Jones : Building Open 27 2018 # 22-00372 New Commercial Building Report Date: 06.02.2022 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments S101 Free text Cody Jones : Building Open 27 Frost depth 36" S101 Free text Cody Jones : Building Open 27 Damp and water proofing to comply with Section 1805. Site grading will need to meet the requirements of 1804.4. S101 Free text Cody Jones : Building Open 27 Ground snow load 50 E1.0 Callout Alex Owens : Electrical Open 42 Current NEC is 2017. E1.0 Callout Alex Owens : Electrical Open 42 Current NEC accepted by Idaho is 2017. E3.0 Free text Alex Owens : Electrical Open 44 Available fault current calculation required. A1.1 Free text Kyle Baldwin : P&Z Open 5 Landscape plan and Site improvements reviewed on permit #18-00315 Report Date: 06.02.2022 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org)