Loading...
HomeMy WebLinkAboutPLANS - 22-00340 - Jody Rawling Meter 2COVER SHEET PHOTOVOLTAIC ROOF MOUNT SYSTEM 217 N 2ND E, REXBURG, ID 83440 USA REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-0 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SYSTEM SUMMARY: ROOF TYPE: - COMP SHINGLE ROOF FRAME: - 2"X4" TRUSSES @ 24" O.C. NUMBER OF LAYERS: - 01 STORY: - ONE STORY SNOW LOAD : - 50 PSF WIND SPEED :- 105 MPH WIND EXPOSURE:- B EXPOSURE CATEGORY:- II DESIGN CRITERIA: PROJECT SITE 2 VICINITY MAP SCALE: NTSPV-0 1 AERIAL PHOTO SCALE: NTSPV-0 ARRAY LOCATIONS PV-0 COVER SHEET PV-1 SITE PLAN WITH ROOF PLAN PV-2 ROOF PLAN WITH MODULES PV-3 ATTACHMENT DETAILS PV-4 BRANCH LAYOUT PV-5 ELECTRICAL LINE DIAGRAM PV-6 ELECTRICAL CALCULATION PV-7 PLACARDS & WARNING LABELS PV-8 ADDITIONAL NOTES PV-9+EQUIPMENT SPEC SHEETS SHEET INDEX (N) 12 - HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES (N) 12 - ENPHASE ENERGY IQ7A-72-2-US MICRO-INVERTERS (N) JUNCTION BOX (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (N) 30A NON-FUSED AC DISCONNECT (N) PRODUCTION METER (N) ENPHASE IQ COMBINER BOX 3 12 MODULES-ROOF MOUNTED - 4.80 kWDC, 3.48 kWAC GENERAL NOTES ·THE CONTRACTOR/INSTALLER OF THE SOLAR PV SYSTEM OVER EXISTING ROOF SHALL CONFORM TO OSHA REQUIREMENTS DURING THE CONSTRUCTION PHASE. JOB SAFETY AND CONSTRUCTION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR/INSTALLER. ·REFER TO ELECTRICAL DRAWING PV-5 FOR PANEL DETAILED INFORMATION. ·IN CASE OF CONFLICT BETWEEN STRUCTURAL DRAWINGS AND ELECTRICAL DRAWINGS, THE MOST RIGID REQUIREMENTS SHALL GOVERN. ·THE CONTRACTOR/INSTALLER SHALL VERIFY ALL EXISTING BUILDING INFORMATION SHOWN (DIMENSIONS, ROOF TOP PROJECTIONS, ETC.) AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO INSTALLATIONS OF PV SYSTEM. ·THE CONTRACTOR/INSTALLER SHALL VERIFY AND COORDINATE EXISTING OPENINGS, ROOF TOP UNITS, VENT PIPES, ETC. SHOWN ON DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE CONTRACTORS/INSTALLER'S RESPONSIBILITY TO NOTIFY ENGINEER PRIOR TO PERFORMING THE WORK. ·ALL CONSTRUCTION IS TO BE PERFORMED IN STRICT CONFORMANCE WITH ALL APPLICABLE TOWN, COUNTY & STATE REGULATIONS AND/OR ANY OTHER GOVERNING BODIES. · DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS. CONTRACTOR MUST CONDUCT ROOF SURVEY TO VERIFY DIMENSIONS SHOWN ON PLAN PRIOR TO INSTALLATION. IF THERE IS A DISCREPANCY IT IS CONTRACTOR/INSTALLER'S RESPONSIBILITY TO NOTIFY THE ENGINEER IMMEDIATELY. ·LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. ·LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. ·DISCONNECT MEANS MUST HAVE DEDICATED CLEAR UNOBSTRUCTED WORKING SPACE NOT LESS THAN 3' DEEP BY 2.5' WIDE TO NOT LESS THAN 6.5' ABOVE WALKABLE SURFACES IN FRONT OF DISTRIBUTION PANEL. ·ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS TO BE BONDED. ·PV ARRAY NOT TO EXCEED HIGHEST POINT OF THE ROOF. ·RAPID SHUTDOWN IS ACTIVED AT THE INVERTER BY THE AC DISCONNECT. GOVERNING CODES: 2017 NATIONAL ELECTRICAL CODE (NEC) 2018 INTERNATIONAL BUILDING CODE (IBC) 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) 2018 INTERNATIONAL FIRE CODE (IFC) 2018 INTERNATIONAL MECHANICAL CODE (IMC) 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) MSP UMACDPVMCB JB ~1 7 2 . 3 7 ' ~111.85' ~1 8 5 . 2 1 ' ~99.01'~20 . 1 6 ' 19'-0"21 ' - 0 " 10 1 ' - 1 1 " 25'-0"MSP UMACDPVMCB JB SITE PLAN WITH ROOF PLAN REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-1 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SITE PLAN WITH ROOF PLAN 1 SCALE: 1/32" = 1'-0" ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ENLARGE VIEW1ASCALE: 1/32" = 1'-0" (N) 3/4" OR GREATER EMT CONDUIT RUN( 7/8" THROUGH THE ATTIC) (N) JUNCTION BOX (E) UTILITY METER (N) PRODUCTION METER (N) 30A NON-FUSED AC DISCONNECT (N) ENPHASE IQ COMBINER BOX 3 (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER ENLARGE VIEW 1A PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E PROPERTY LINE (E) TREES (TYP.)ONE- STORY HOUSE EXISTING DRIVEWAY N 2ND E ROOF #1 (12) HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES ROOF ACCESS POINT EXISTING PARKING MSP UMACDPVMCB JB 14 ' - 0 " 6' - 2 " 11 ' - 4 " 7'-11"42'-0"26'-4" REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-2 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com ROOF PLAN WITH MODULES ROOF PLAN WITH MODULES SCALE: 3/32" = 1'-0"1 74.0" 41 . 1 " PHOTOVOLTAIC MODULES HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 12 MODULES MODULE TYPE = HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES MODULE WEIGHT = 48.5 LBS / 22.0 KG. MODULE DIMENSIONS = 74.0"X 41.1" = 21.12 SF UNIT WEIGHT OF ARRAY = 2.30 PSF · PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED. ALL ELECTRICAL EQUIPMENT, INVERTERS, DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL NOT BE INSTALLED WITHIN 3’ OF THE GAS METERS SUPPLY OR DEMAND PIPING. NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS LEGEND - UTILITY METER MSP - MAIN SERVICE PANEL - AC DISCONNECT - JUNCTION BOX - ENPHASE IQ COMBINER BOX 3 - VENT, ATTIC FAN (ROOF OBSTRUCTION) - ROOF ATTACHMENT - TRUSSES - CONDUIT - FIRE PATHWAY - CHIMNEY - PRODUCTION METER UM ACD CB JB PVM (E) COMP SHINGLE ROOF (TYP.) (N) (23) IRONRIDGE FLASHFOOT2 ATTACHMENTS SPACED AT 48" O.C. (E) UTILITY METER (N) PRODUCTION METER (N) 30A NON-FUSED AC DISCONNECT (N) ENPHASE IQ COMBINER BOX 3 (E) CHIMNEY (TYP.) (N) JUNCTION BOX (N) 3/4" OR GREATER EMT CONDUIT RUN( 7/8" ABOVE THE ROOF) ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 12 253.45 2256.32 11.23 ROOF DESCRIPTION ROOF TYPE COMP SHINGLE ROOF ROOF ROOF TILT AZIMUTH TRUSSES SIZE TRUSSES SPACING #1 20°180°2"x4"24" O.C. ROOF #1 (12) HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES N 2ND E FRONT YARD REAR YARD ROOF #1 TILT - 20° AZIMUTH - 180° 18" FIRE PATHWAY 18" FIRE PATHWAY 36 " F I R E P A T H W A Y 36 " F I R E P A T H W A Y (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (N) IRONRIDGE XR 100 RAIL (E) 2"X4" TRUSSES @ 24" O.C. (TYP.) BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION RAIL 06 IRONRIDGE XR 100 RAIL SPLICE 04 XR-BONDED SPLICE MID CLAMP 22 IRONRIDGE MID CLAMP-UFO END CLAMP 04 IRONRIDGE END CLAMP-STOPPER SLEEVES ATTACHMENT 23 IRONRIDGE FLASHFOOT2 GROUNDING LUG 1 XR-LUG REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-3 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com ATTACHMENT DETAIL ATTACHMENT DETAIL SCALE: NTS1 ATTACHMENT DETAIL (ENLARGED VIEW) SCALE: NTS2 NOTE: ACTUAL ROOF CONDITIONS AND TRUSSES (OR SEAM) LOCATIONS MAY VARY. INSTALL PER MANUFACTURER(S) INSTALLATION GUIDELINES AND ENGINEERED SPANS FOR ATTACHMENTS ENLARGED VIEW PV MODULE 2"x4" TRUSS E S @ 24" O.C (E) COMP SHINGLE ROOF IRONRIDGE INTEGRATED GOUNDING & END/MID CLAMP ALUMN. "L" BRACKET W/3/8" SS BOLT & NUT IRONRIDGE FLASHFOOT2 ATTACHMENTS (E) 2"x4" TRUSSES @ 24" O.C 5/16"x3.5" SS LAG BOLT WITH MIN 212" THREAD EMBEDMENT, SEALED PENETRATION PV MODULES (E) COMP SHINGLE ROOF IRONRIDGE XR 100 RAIL 2.5" MI N . EMBED M E N T ROOF / DECK MEMBRANE REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-4 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com BRANCH LAYOUT SCALE: 1/8" = 1'-0"1 BRANCH LAYOUT (12) HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES (12) ENPHASE ENERGY IQ7A-72-2-US MICRO-INVERTERS (02) BRANCHES OF 06 MODULES CONNECTED IN PARALLEL 3' - 0 " 36" FIRE PATHWAY 18 " 18" FIRE PATHWAY 36 " F I R E P A T H W A Y 36 " F I R E P A T H W A Y 18" FIRE PATHWAY 18" FIRE PATHWAY ROOF #1 (12) HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES (12) ENPHASE ENERGY IQ7A-72-2-US MICRO-INVERTERS BRANCH #2 N 2ND E FRONT YARD REAR YARD BRANCH #1 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-5 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com ELECTRICAL LINE DIAGRAM ELECTRICAL LINE DIAGRAM SCALE: NTS1 UTILITY PROVIDER: MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN CIRCUIT BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: PACIFICCORP. 240V GENERAL ELECTRIC (E) 200 A (E) 200 A NORTH SERVICE INFO. OVERHEAD BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 12 HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES INVERTER 12 ENPHASE ENERGY IQ7A-72-2-US MICRO-INVERTERS JUNCTION BOX 1 600V, 55A MAX, 4 INPUTS, MOUNTED ON ROOF FOR WIRE & CONDUIT TRANSITION COMBINER BOX 1 ENPHASE IQ COMBINER 3, X-IQ-AM1-240-3 AC DISCONNECT 1 30A NON-FUSED, AC DISCONNECT 240VAC, NEMA 3R, UL LISTED PV METER 1 PRODUCTION METER (E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (TOP FED)L EXISTING GROUNDING SYSTEM 200A BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V, 60Hz 12 MODULES X 1.45A= 17.40 A 17.40A X 1.25 = 21.75 A (3) #10 AWG THWN (1) #8 AWG THWN GND IN 3/4" EMT CONDUIT RUN G (N) AC DISCONNECT 30A NON-FUSED, 240 VAC (12) HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES (12) ENPHASE ENERGY IQ7A-72-2-US MICRO-INVERTERS (02) BRANCHES OF 06 MODULES CONNECTED IN PARALLEL SYSTEM SIZE:- 12 x 400W = 4.80 kWDC SYSTEM SIZE:- 12 x 290W = 3.48 kWAC M (N) PV METER (N) 30A PV BREAKER 30A INTERCONNECTION 120% RULE - NEC 705.12(B)(2)(3)(b) UTILITY FEED + SOLAR BACKFEED 200A + 30A = 230A BUSS RATING x 120% 200A x 120% = 240A NOTE: TANDEM EXISTING BREAKERS TO MAKE ROOM FOR NEW PV BREAKER TERMINATOR CAP ON LAST CABLE CONNECTOR AC TRUNK CABLE (TYP) 06 MICRO-INVERTERS IN BRANCH CIRCUIT #2 06 MICRO-INVERTERS IN BRANCH CIRCUIT #1 G (4) #10 AWG THWN-2 (1) #8 AWG THWN-2 GND IN 3/4" EMT CONDUIT RUN JUNCTION BOX G ENVOY MICRO-INVERTER 20A 10A 20A (2) Q-CABLE (1) #6 BARE CU GND (N) ENPHASE IQ COMBINER 3, X-IQ-AM1-240-3 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-6 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com ELECTRICAL CALCULATION SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES VMP 37.13 IMP 10.77 VOC 45.20 ISC 11.14 MODULE DIMENSION 74.0"L x 41.1"W x 1.57"D (In Inch) INVERTER SPECIFICATIONS MANUFACTURER / MODEL #ENPHASE ENERGY IQ7A-72-2-US NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 1.45A AMBIENT TEMPERATURE SPECS WEATHER STATION: IDAHO FALLS FANNING FIELD RECORD LOW TEMP -26° AMBIENT TEMP (HIGH TEMP 2%)33° CONDUIT HEIGHT 0.9" ROOF TOP TEMP 33° CONDUCTOR TEMPERATURE RATE (ON ROOF)90° CONDUCTOR TEMPERATURE RATE (OFF ROOF)75° MODULE TEMPERATURE COEFFICIENT OF Voc -0.29%/°C PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT .80 4-6 .70 7-9 .50 10-20 ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 & 75 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE AC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO COMBINER BOX: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT EXPECTED WIRE TEMP (°C): 33° TEMP CORRECTION PER TABLE 310.15(B)(2)(a): 0.96 # OF CURRENT CARRYING CONDUCTORS: 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(3)(a): 0.8 CIRCUIT CONDUCTOR SIZE: 10 AWG CIRCUIT CONDUCTOR AMPACITY: 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B): 1.25 X # MICRO-INVERTERS (MAX. BRANCH LENGTH) X MAX OUTPUT CURRENT 1.25 X 06 X 1.45A = 10.88A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.15(B)(2)(a) TEMP CORR. PER NEC TABLE 310.15(B)(2)(a) X CONDUIT FILL CORR. PER NEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY = 0.96 X0.8X 40 = 30.72A AC CONDUCTOR AMPACITY CALCULATIONS: FROM COMBINER BOX TO INTERCONNECTION: # OF INVERTERS: 12 EXPECTED WIRE TEMP (°C): 33° TEMP CORRECTION PER TABLE 310.15(B)(2)(a): 0.94 # OF CURRENT CARRYING CONDUCTORS: 3 CONDUIT FILL PER NEC 310.15(B)(3)(a): 1.0 CIRCUIT CONDUCTOR SIZE:10 AWG CIRCUIT CONDUCTOR AMPACITY: 35 A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): 1.25 X # MICRO-INVERTERS X MAX OUTPUT CURRENT = 1.25 X 1.45 X 12 = 21.75A DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.16: TEMP CORR. PER NEC TABLE 310.15(B)(2)(a) X CONDUIT FILL CORR. PER NEC 310.15(B)(3)(a) X CIRCUIT CONDUCTOR AMPACITY = 0.94 X 1.0 X 35= 32.9A RESULT SHOULD BE GREATER THAN (10.88A) OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY RESULT SHOULD BE GREATER THAN (21.75A) OTHERWISE LESS THE ENTRY FOR CIRCUIT CONDUCTOR SIZE AND AMPACITY ELECTRICAL CALCULATION SCALE: NTS1 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-7 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com WARNING LABELS & PLACARD CAUTION ! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AT:MAIN SERVICE PANEL & UTILITY METER, AC DISCONNECT & COMBINER BOX, PRODUCTION METER (N) PV MODULES WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: AC DISCONNECT & INVERTER (PER CODE: NEC690.54) PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 17.4 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS LABEL LOCATION: SERVICE PANEL IF SUM OF BREAKERS EXCEEDS PANEL RATING (PER CODE: NEC 705.12 (B)(2)(3)(b) LABEL LOCATION: AC & DC DISCONNECT AND SUB PANEL (PER CODE: NEC 690.13(B)) WARNING:PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: EMT / CONDUIT RACEWAYS (PER CODE: NEC 690.31(G)(3) TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING ELECTRIC SHOCK HAZARD ! LABEL LOCATION: MAIN SERVICE PANEL & NET METER (PER CODE: NEC 705.12(D)(3), NEC 705.12(B)(3-4) & NEC 690.59) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: MAIN SERVICE DISCONNECT / UTILITY METER (PER CODE: NEC 690.13(B)) LABEL LOCATION: AC DISCONNECT, DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: 605.11.3.1(1) & 690.56(C)(1)(a)) WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM ! SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT NEC 690.13(B) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: RAPID SHUTDOWN (PER CODE: NEC 690.56(C)(3) ! (N) PRODUCTION METER (E) UTILITY METER (N) AC NON-FUSED DISCONNECT(E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER (N) COMBINER BOX 3 217 N 2ND E SOLAR METER PARALLEL GENERATION ON SITE LOCATION: NEXT TO AC DISCONNECT 3" 4.5" MANUAL DISCONNECT FOR PARALLEL GENERATION 4" 2" LOCATION: NEXT TO METER REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-8 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com ADDITIONAL NOTES 1.EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER MANUFACTURER'S REQUIREMENTS. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS ARE TO BE BONDED. IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 2.ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL ELECTRICAL CODE. LABEL SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED IN A CONTRASTING COLOR TO THE PLAQUE. PLAQUE SHALL BE UV RESISTANT IF EXPOSED TO SUNLIGHT. 3.AC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION AC CIRCUIT" OR EQUIV. EVERY 5 FT. 4.EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A). 5.CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER. VERIFY SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. 6.OUTDOOR EQUIPMENT SHALL BE NEMA-3R RATED OR BETTER. 7.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC. 8.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE, AND FOR ROOF-MOUNTED SYSTEMS, WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. NEC 110.2 - 110.4 / 300.4 REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-9 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SPEC SHEETS REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-10 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SPEC SHEETS REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-11 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SPEC SHEETS REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-12 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SPEC SHEETS REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-13 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SPEC SHEETS REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-14 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SPEC SHEETS REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-15 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SPEC SHEETS REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-16 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SPEC SHEETS REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-17 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SPEC SHEETS REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-18 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SPEC SHEETS REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-19 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SPEC SHEETS REV SHEET NAME SHEET NUMBER DATEDESCRIPTION VERSION PV-20 PROJECT NAME UR05/08/2022INITIAL RELEASE JO D Y R A W L I N G S 21 7 N 2 N D E , RE X B U R G , ID 8 3 4 4 0 U S A AP N # RP R R X B 1 0 1 2 4 3 3 1 UT I L I T Y : PA C I F I C C O R P . AH J : CI T Y O F R E X B U R G SHEET SIZE ANSI B 11" X 17" HORIZON PWR SC LLC 237 N 2ND E SUITE 202 , REXBURG ID,83440 USA CSLB # :RCE-56878 TEL: (888) 468-7180 Email: permitting@horizonpwr.com SPEC SHEETS