Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUBMITTAL - 22-00306 - Yellowstone Heights - Fire Alarm
Page 1 of 1 Idaho Owned and Operated FAX # 1-208-232-0449 FIRE ALARM MATERIAL SUBMITTALS for the YELLOWSTONE HEIGHTS Apartments DN-60959:C • 7/16/2018 — Page 1 of 4 NFW-100X Intelligent Addressable FACP with Communicator General The FireWarden-100X (NFW-100X) is the latest intelligent address- able Fire Alarm Control Panel (FACP) within the FireWarden Series and is a direct replacement for the FireWarden-100 (NFW-100). The NFW-100X comes with a pre-installed communicator and supports up to 198 addressable devices (99 detectors and 99 modules). With an extensive list of powerful features, the NFW-100X programs just like FireWarden-100 products, yet fits into applications previously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator’s internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-N. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel’s USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTM). Features • Listed to UL Standard 864, 10th edition • Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator over AlarmNet • Optional CELL-MOD or CELL-CAB-N GSM Central Station Com- municator over AlarmNet® • Automated activation of the NFC-50/100 Emergency Command Center • NFC-FFT Firefighter Telephone option • Compatible with SWIFT® wireless devices • Auto-programming (learn mode) reduces installation time. Reports two devices set to the same address • Four built-in, independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices • Notification Appliance Circuit End of Line resistor matching • Four programmable function keys for ease of maintenance • Two programmable relays and one fixed trouble relay • Built-in Programmer • Integral 80-character LCD display with backlighting • Real-time clock/calendar with automatic daylight savings control • History file with 1,000 event capacity • Addressable sounder base compatibility • Control module delay timer • Automatic detector sensitivity testing (NFPA 72 compliant) • Automatic device type-code verification • Point trouble identification • Waterflow selection per module point • Alarm verification selection per detector point • Maintenance alert warns when smoke detector dust accumula- tion is excessive • One-person audible or silent walk test with walk-test log and printout • System alarm verification selection per detector point • PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant) • Up to 16 ANN-BUS annunciators- 8 per each ANN-Bus • Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator • Upload/Download of program and data via USB with optional FS- Tools Programming Utility SLC COMMUNICATION LOOP • Supports FlashScan® and CLIP protocols • SLC operates up to 10,000 ft. (3,000 m) in FlashScan mode with twisted, unshielded wire • Single addressable SLC loop which meets NFPA Class B and Class A requirements • 198 addressable device capacity (99 addressable detectors and 99 modules) • Compatible with NOTIFIER FireWarden and ONYX Series addressable devices (refer to the FireWarden SLC Wiring Man- ual) NOTIFICATION APPLIANCE CIRCUITS (NACS) • Four independently programmable output circuits. Circuits can be configured for the following outputs: –Style Y (Class B) –Style Z (Class A) • Silence Inhibit and Autosilence timer options • Continuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capability • Selectable strobe synchronization per NAC • 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A Page 2 of 4 — DN-60959:C • 7/16/2018 PROGRAMMING AND SOFTWARE • Autoprogramming (learn mode) reduces installation time • Custom English labels (per point) may be manually entered or selected from an internal library file • Two programmable Form-C relay outputs • 99 software zones • Continuous fire protection during online programming • Program Check automatically catches common errors not linked to any zone or input point •OFFLINE PROGRAMMING: Create the entire program in your office using FS-Tools, a Windows®-based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS-Tools is available on www.notifier.com. User interface LED INDICATORS KEYPAD PRODUCT LINE INFORMATION NFW-100X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display chassis with trans- former, backbox with door, plastic bag containing screws, cables, key, etc. FS-Tools: Programming software for Windows®-based PC com- puter. Available for download at www.notifier.com. CELL-CAB-N/CELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP-ES-R: Optional dress panel for the NFW-100X (red). DP-ES-B: Optional dress panel for NFW-100X (black). TR-CE-B: Optional trim ring for semi-flush mounting. (Black. For red, order TR-CE.) BB-XP: Optional cabinet for one or two modules. BB-25: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG- 75. NFS-LBB: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-25 cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120: Remote battery charging system for lead-acid batteries with a rating of 55 to 120 AH. Requires additional NFS-LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than 18AH. BAT Series: Batteries, see data sheet DN-6933. PRN Series: UL listed compatible event printer. Uses tractor-fed paper. OPTIONAL MODULES 4XTM Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. PWRMOD24 Power Expander Module: Optional power module. Increases alarm power output to 6 amps. COMPATIBLE ANNUNCIATORS N-ANN-80: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. (Basic model is black; order -W for white; see DN-7114.) N-ANN-100R: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. (Basic model is black; order R for red.) N-ANN-I/O: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DN-7105.) N-ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DN-60242.) N-ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DN-60242.) N-ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DN-7107.) N-ANN-S/PG: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DN-7103.) ADDRESSABLE DEVICES FSP-951: Addressable low-profile photoelectric smoke detector. FlashScan only. FSP-951-IV: Addressable low-profile photoelectric smoke detector. Ivory. FlashScan and CLIP mode. NP-200: Addressable low-profile photoelectric smoke detector. B300-6 base included, FlashScan only. NP-200-IV: Addressable low-profile photoelectric smoke detector. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951T: Addressable low-profile photoelectric smoke detector with thermal sensor. FlashScan only. FSP-951T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory. FlashScan and CLIP mode. NP-200T: Addressable low-profile photoelectric smoke detector with thermal sensor. B300-6 base included. FlashScan only. NP-200T-IV: Addressable low-profile photoelectric smoke detector with thermal sensor. Ivory, B300-6-IV base included. FlashScan and CLIP mode. FSP-951R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. FSP-951R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. FlashScan and CLIP mode. NP-200R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FlashScan only. NP-200R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory, FlashS- can and CLIP mode. FST-951: Low-profile 135°F fixed thermal sensor. FlashScan only. FST-951-IV: Low-profile 135°F fixed thermal sensor. Ivory. FlashS- can and CLIP mode. NH-200: Low-profile 135°F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200-IV: Low-profile 135°F fixed thermal sensor. Ivory. B300-6-IV base included, FlashScan and CLIP mode. FST-951R: Low-profile, intelligent, rate-of-rise thermal sensor. FlashScan only. FST-951R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. FlashScan and CLIP mode. • Fire Alarm (red) • CO Alarm (red) • AC Power (green) • Supervisory (yellow) • Trouble (yellow) • Ground fault (yellow) • Battery fault (yellow) • Disabled (yellow) • Maintenance (yellow) • Communication (yellow) • Alarm Silenced (yellow) • F1-F4 Programmable Function Keys (yellow) • 16 key alpha-numeric pad • Acknowledge • Alarm Silence • Drill (Manual Evacuate) • Four (4) programmable function keys • Reset (lamp test) DN-60959:C • 7/16/2018 — Page 3 of 4 NH-200R: Low-profile 135°F fixed thermal sensor. B300-6 base included, FlashScan only. NH-200R-IV: Low-profile 135°F fixed thermal sensor. Ivory. B300-6- IV base included, FlashScan and CLIP mode. FST-951H: Low-profile intelligent 190°F/88°C fixed thermal sensor. FlashScan only. FST-951H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- sor. Ivory. FlashScan and CLIP mode. NH-200H: Low-profile intelligent 190°F/88°C fixed thermal sensor. B300-6 base included, FlashScan only. NH-200H-IV: Low-profile intelligent 190°F/88°C fixed thermal sen- sor. Ivory. B300-6-IV base included, FlashScan and CLIP mode. Legacy Devices FSI-851: Addressable low-profile ionization smoke detector. NI-100: Addressable low-profile ionization smoke detector. FSP-851: Addressable low-profile photoelectric smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. FSP-851T: Addressable low-profile photoelectric smoke detector with thermal sensor. NP-100T: Addressable low-profile photoelectric smoke detector with thermal sensor. FSP-851R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. NP-100R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. FST-851: Fast-response, low-profile heat detector. NH-100: Fast-response, low-profile heat detector. FST-851R: Fast-response, low-profile heat detector with rate-of-rise option. NH-100R: Fast-response, low-profile heat detector with rate-of-rise option. FST-851H: Fast-response, low-profile heat detector that activates at 190°F/88°C. NH-100H: Fast-response, low-profile heat detector that activates at 190°F/88°C. FAPT-851: Addressable low-profile multi-sensor detector. NP-A100: Addressable low-profile multi-sensor detector. B200S: Programmable, addressable sounder base. B200SR: Addressable sounder base. DNR: InnovairFlex low-flow non-relay duct-detector housing. (Order FSP-851R, FSP-951R, or NP-100R separately.) DNRW: InnovairFlex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order FSP-851R, FSP-951R, or NP-100R separately.) Addressable Modules FMM-1: Addressable Monitor Module for one zone of normally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NMM-100: Addressable Monitor Module for one zone of normally- open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. FDM-1: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only IDCs. NDM-100: Dual Monitor Module. Same as NMM-100 except it pro- vides two Style B (Class B) only IDCs. FMM-101: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. FZM-1: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. NZM-100: Similar to NMM-100. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. FCM-1: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. FRM-1: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NBG-12LX: Addressable manual pull station with interface module mounted inside. NOT-BG12LX: Addressable manual pull station with interface mod- ule mounted inside. ISO-X: Fault Isolator Module. N100-ISO: Fault Isolator Module. ISO-6: Six-fault isolator module. Mount one or two modules in a BB- XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SMB500: Used to mount all modules except the FMM-101/NMM- 100P. NMM-100-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NZM-100-6: Six-zone interface module. Mount one or two modules in a BB-XP cabinet (optional). Mount up to six modules on a CHS-6 chassis in a CAB-3/CAB-4 series cabinet. SWIFT Wireless Devices FWSG: Wireless Gateway FWD-200P: intelligent, wireless photo detector. FWH-200ROR135: LiteSpeed intelligent wireless rate of rise (135°) heat detector. FWD-200ACCLIMATE: Wireless Acclimate Detector FWH-200FIX135: intelligent wireless fixed-temperature (135°) heat detector. FW-MM: Intelligent wireless monitor module. FW-RM: Intelligent wireless relay module. NBG-12LW: Intelligent wireless pull station. WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: Intelligent AV bases. W-USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the FireWarden-100X, see the following data sheets (document numbers): NP-200 Series (DN-60979), NH-200 Series (DN-60980), FSP-851 Series (DN-6935), FSP-951 Series (DN-60977), FST-851 Series (DN-6936), FST-951 Series (DN-60975), FAPT-851 (DN-6937), N100-ISO (DN-6994), NP-100 series (DN-6995), NH-100/NH-100R (DN- 6997), DNR/InnovairFlex (DN-60424, DN-60429), NP-A100 (DN-6998), NMM-100/NMM-100P/NDM-100/NZM-100 (DN-6999), NC-100 (DN- 7000), NC-100R (DN-60383), NMM-100-10 (DN-6990), MM-1/FDM-1/ FZM-1/FMM-101 (DN-6720), FCM-1/FRM-1 (DN-6724), NOT-BG12LX (DN-7001), NBG-12LX (DN-6726), and FireWarden SLC Manual (52304). AlarmNet®, NOTIFIER®, FireWarden®, SWIFT®, and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of Origin: USA NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com SPECIFICATIONS System Capacity • Intelligent Signaling Line Circuits................................................1 • Addressable device capacity..................................................198 • Programmable software zones.................................................99 • Annunciators.............................................................................16 Electrical Specifications AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, auto-sensing- no switch required. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Capacity: 7-18 AH (FireWarden-100X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides connec- tions for four NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA regulated. End-of-Line Resistor: 4.7k ohm, ½ watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 kΩ - 22 kΩ ELR range. Refer to the NOTIFIER Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, non-power-limited, non-supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE/B): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00” (50.80 cm.) high x 22.5” (57.15 cm.) wide x 8.5” (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 – 49°C/32 – 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 – 27°C/60 – 80°F. Addressable Device Accessories End-of-Line Resistor Assembly (R-47K and R-3.9K): The 47k ohm assembly supervises the NMM-100-10, NDM-100, NMM- 100P, and NC-100 module circuits. The 3.9k ohm assembly super- vises the NZM-100-6 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. NFPA Standards The FireWarden-100X complies with the following NFPA 72 Fire Alarm Systems requirements: – LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). – AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). – REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) – PROPRIETARY (Automatic, Manual and Waterflow). – CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). –OT, PSDN (Other Technologies, Packet-switched Data Net- work) – IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). – CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic FireWarden- 100X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL: S635 •CSFM: 7165-0028:0505 •FDNY: COA #6268 Commercial Fire Alarm Cellular &/or IP Fire Alarm LTE Communicators COMMERCIAL FIRE CELLULAR & IP • Sole Path Cellular and Dual Path Cellular &/or IP Models • Choice of plans (varies by model) - check-ins from 200 seconds, to 5-minutes to 1 hour, Verizon LTE Network • Patented Signal Boost™ and Dual Diversity Antennae for maximum signal acquisition & null avoidance, receiving signals simultaneously on both antennae • Money-saving Tradeup incentive credit • Bonus: Full High-Speed Napco Panel remote uploading/ downloading • COMPLIANCES: NFPA72 Editions: 2016, 2013, 2010, 2007; UL 864, 9th Ed., UL1610, UL985, UL1023, NYCFD; CSFM; LAFD Napco StarLink Universal Fire Alarm Communicators • Universal full event sole & dual path cellular &/or IP commercial fire alarm reporting from any panel brand, virtually anywhere • Code-compliant, replaces 2POTs lines per FACP saves thousands of dollars per year over the leased landlines • Supports 12V-24 control panels and FACPs that communicate using Contact ID and 4/2 (such as on legacy panels), as primary or backup • Full data Reporting to any Central Station nationwide, via Verizon® LTE Network, “The Nations largest and most reliable LTE network. Rated #1 overall network, proven to deliver consistently fast speeds ad i more places than any other network” ‡ • Communicate critical life and safety alarm reports on LTE (Long Term Evolution) 10+ year life, cyber-protected multi-billion dollar cellular network, for maximum life safety & liability protection • Easiest installation, powered by panel, NO extra power supply, NO conduit, self supervised on 4 wires • Over-the-Air Upgradeable Communicator Firmware. Remote ability for critical/mandatory updates, without a truck-roll • Cost-saving models and plans for any code requirement. Substantial savings over monthly dedicated landline charges. And, $100 saving incentive for system upgrades from old radios (all makes) and old POTs landlines, as well as new installations Code-compliant standard or mercantile metal models (right and left, respectively) . UL and NFPA 72 Fire Code-Compliant, the StarLink Series Wireless Commercial Fire Alarm Sole Path & Dual Path Communicators provide universal support for any brand 12V to 24V fire alarm control panel, reporting in Contact ID and 4/2. With broadest Verizon LTE coverage footprint available, via most extensively deployed LTE CAT1, using proven StarLink circuitry , they are also available in mercantile locking metal models. All provide the most economical solution for easy, versatile installation. Also regional compliances, i.e., CSFM, NYCFD, LAFD and more. Easy, Universal Installation at Every Application; Panel- Powered Technology™. StarLink Fire Communications are easily connected to any panel or Fire Alarm Control Panel (FACP) standardly operating between 12V and 24V. Flexible in any application, StarLink Fire also comes in standard, or Mercantile Models in metal housings, with code-compliant supervision, and choice of power options, Panel-Powered Technology™ (powered by the panel), or direct-connect 120VAC models. Signal Boost circuitry & dual diversity antennae for maximum signal acquisition & null avoidance, receiving signals simultaneously on both antennae. Flexible Performance & Reporting Options. StarLink Fire provides full data reporting, in sole and dual path, as a primary or backup, to any central station of your choice, without requiring any special equipment on premises. Ultra-affordable plans are available to meet various codes and requirements, with supervisory check-ins from 200 seconds, to 5 minutes, to an hour. The units are very easily activated, plans and options are selected, and 24/7 account management is provided all through www.napcocomnet.com. Commercial Fire Alarm Cellular &/or IP Fire Alarm LTE Communicators COMMERCIAL FIRE CELLULAR & IP StarLink Fire Specifications STANDARD MODELS: • Advanced LTE Dual Diversity Antennae for optimized performance • Durable ABS plastic housing includes three keyhole slots for mounting (for commercial application, aligns with triple gang boxes ) • Panel Powered Technology™ (powered by panel), Low current draw, 71mA standby, 200mA transmit • Dimensions: 5-3/8”x 7-7/8”x 1-7/8” (HxWxD) • Weight: 13.5 oz • 3 LED Indicators - Green, Signal Strength; Amber- Busy/ Activation; Red-Trouble • Patented Signal Boost™ signal amplification circuit and high- gain performance antennae • Operating Environment: 0 to 49º C (32-120ºF), up to 93% humidity (non-condensing) • 12V - 24V Universal FACP Support, auto-current sensing. Support all brands communicating in Contact ID and 4/2 MERCANTILE MODELS (similar to above, with): • Locking Metal Enclosure with Hinged door & 2 key-slots for wall mounting (LED indicators, inside) • Dimensions: 9-5/8”x 11-3/4” x 3-3/8”D (HxWxD) • Weight: 8 lbs (max., power supply models) • Electrical Ratings for 120VAC, 60Hz • For Models with Power Supply: • Input Voltage: 120VAC Nominal • Input Current: 400mA maximum • Maximum Charging Current: 200mA • Electrical Ratings for +12V • For Models without Power Supply: • Input Voltage: 11-15VDC (power-limited output from listed control panel) • Input Current: 71mA with peak RF transmission current of 200mA • Electrical Ratings for the IN 1 Burg/Fire Input: • Input Voltage: 9-15VDC • Maximum Input Current: Up to 2mA from FACP NAC circuit • Electrical Ratings for IN 2 and IN 3: • Maximum Loop Voltage: 15VDC • Maximum Loop Current: 1.2mA • Electrical Ratings for 3 PGM Outputs: • Open Collector Outputs: Maximum voltage 3V when active; 15V maximum when not active • Maximum PGM Sink Current: 50mA mount • Operating Environment 0 to 49º C (32-120ºF), up to 93% humidity (non-condensing) • 12V - 24V Universal FACP Support, auto-current sensing. Support all brands communicating in Contact ID and 4/2 Ordering Information COMMERCIAL FIRE SOLE PATH CELLULAR & DUAL PATH CELLULAR &/OR IP (“I” MODELS):* SLE-LTEVI-FIRE Dual Path Communicator, Cellular &/or IP, connected by Verizon LTE™, ABS. Low current draw, panel- powered technology™ (powered by control panel) SLE-LTEV-FIRE as above, but sole path cellular model SLELTEVI-CFB Commercial Fire Dual Path Mercantile model in red metal housing on LTE, Verizon LTE Network, powered directly from control panel SLETEVI-CFB-PS Commercial Fire Dual Path Mercantile model in red metal housing, LTE, Verizon LTE Network. Direct 120VAC Powered (w/ provisions for backup battery/charger). Or, Optional TRF12 plug-in transformer may be used, where codes permit ACCESSORIES: Free Commercial Fire Tradeup Trifold Brochures / Mailers/Stuffers (A720) for new and existing fire accounts SLE-ANTEXT75 Optional extended antenna with 75’ cable (new conical shape) SLE-ANTEXT50 As above, with 50’ cable SLE-ANTEXT30 As above, with 30’ cable SLE-DLEXT Optional, as above, for downloading, extends distance to Napco panel up to 100’ TRF12 Optional Plug in AC Transformer, 16.5V / 20VA (use is subject to local code compliance) SLE-DLCBL Optional High-Speed Napco Panel Up/download cable 333 Bayview Ave., Amityville, NY 11701 USA 1-800-645-9445 • Fax: 1-631-789-9292 www.napcosecurity.com StarLink, StarLink Fire, FireLink, SignalBoost, Panel-Powered Technology, Gemini & Gemini Commercial are trademarks of Napco. Verizon, LTE, etc. are trademarks of their respective companies. * StarLink offers full data coverage in US from virtually all panel brands reporting in Contact ID or 4/2. For full details on the StarLink tradeup incentive see online under http://www.napcosecurity.com/starlink/starlink4gupgrade/ †Promo subject to change w/o prior notice. LTE lifespan claims are based on those of carriers. ‡Verizon® rankings based on the RootMetrics US National RootScore® Report: 1H 2017. ©NAPCO, NAPCO Security Technologies Inc. (NASDAQ:NSSC) A734 2018.9 COMMERCIAL FIRE CELLULAR & IP Award Winning FL-FACP-LTEVS Firewolf 8 Zone 24V Conventional Commercial Fire Alarm Control Panel with onboard StarLink Fire® Sole Path, Verizon LTE Cellular Alarm Communicator and integral menu-driven LCD annunciator, w/ 4amp, 24V power supply. Optionally expandable up to 32 points/zones via commercial addressable, wireless or conventional fire devices (2 onboard NACs providing up to 4A notification power). Locking, mercantile red enclosure,(surface or flush mount*) removable 16”x17” door with 14.25”x16” base. Houses 16Ah battery backup New! FireLink™ Integrated Fire Alarm Control Panel w/ StarLink Fire LTE Built In DF-61093:C • 3/10/2021 — Page 1 of 2 FL-PS6(C) & FL-PS10(C) 6 Amp and 10 Amp, 24 Volt Remote Power Supplies Power Supplies/Accessories DF-61093:C • D-60 General The PS Series is a remote power supply line from Fire•Lite Alarms and is a direct replacement for the FCPS-24FS6/8 Series. The FL- PS6(C) is a 6 amp and the FL-PS10(C) is a 10 amp, remote power supply with battery charger that may be connected to any 12 or 24 volt fire alarm control panel (FACP) or used as a standalone power supply. The PS Series provides 24 VDC power for NACs (notifica- tion appliance circuits) configured as either Class B or Class A (requires the ZNAC-PS option card) with multiple sync protocol options. The PS Series also provides auxiliary power, constant or resettable, suited for detectors, annunciators, door holders, and other fire alarm system peripherals. The PS Series cabinet can hold two 7 AH or 18 AH batteries and can charge up to 33 AH batteries in a separate cabinet. Features • Up to five (6 amp model) or seven (10 amp model) inde- pendently-configurable, power-limited output circuits for: –Class B and/or Class A NACs –Class B and/or Class A resettable or non-resettable 24V auxil- iary power –door holder power • Converts from Class B to Class A wiring without losing any out- puts using the ZNAC-PS converter card (sold separately) • Optimal for powering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated power • Configurable for ANSI® Temporal 3 or Temporal 4 coded output • UL-Listed NAC synchronization using System Sensor®, Whee- lock®, Gentex®, or AMSECO® appliances • Synchronization can be triggered from FACP NAC/remote sync outputs, cascaded power supply, or a control module, single or multi, which may be housed within the power supply cabinet • Ability to cascade up to four power supplies • Two (6 amp model) or three (10 amp model) fully-isolated input/ control circuits which can be programmed to any output • Two Form C normally-closed trouble relays for AC Trouble and General Trouble, Ground Fault relay available on Canadian mod- els only • 6 or 10 amp full load output, respectively, with 3 A maximum/cir- cuit • Individual NAC power and trouble LEDs for diagnostic efficiency • Trouble history modes for diagnostic support • Wide range end-of-line supervision value (normal: 2K-27K ohms) • Selectable earth fault detection (enable or disable) • AC trouble report delay timer • Completely configurable via onboard DIP switches, no extra soft- ware required • Self-contained in compact, locking cabinet constructed of heavy gauge steel with a corrosion-resistant powder coat chip and scratch-resistant finish • Cabinet designed with ten double knockouts and a removable door for ease of installation and wiring • Includes integral battery charger capable of charging up to 33 AH batteries • Cabinet can house two 7 AH or 18 AH batteries • Battery charger may be disabled via DIP switch for applications requiring larger batteries and external battery charger • Removable terminal blocks accommodate up to 12 AWG (3.1mm2) wire • Works with any UL 864 FACP which utilizes an industry-standard reverse-polarity notification circuit • Optional devices include addressable control, monitor, and relay modules and power-supervision relay (EOLR-1) Standards and Codes The FL-PS Series comply with the following standards: •NFPA 72 National Fire Alarm Code •UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode), 10th Edition •UL 1481 Power Supplies for Fire Alarm Systems •IBC 2009 (when using SEISKIT-MULTI-1) •CBC 2007 (when using SEISKIT-MULTI-1) Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. •UL Listed: S2424 •ULC Listed: S2424 (FL-PS6/10C) •CSFM Approved: 7315-0075:0510 •FDNY Approved •FM Approved Fire•Lite® Alarms and System Sensor® are registered trademarks of Honeywell International, Inc. Wheelock® is a registered trademark of Cooper Technologies Company. Gentex® is a registered trademark of Gentex Corporation. AMSECO® is a registered trademark of Potter Electric Signal Company, LLC. ANSI® is a registered trademark of the American National Standards Institute, Inc. ©2020 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Page 2 of 2 — DF-61093:C • 3/10/2021 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Country of Origin: USA SYSTEM SPECIFICATIONS Primary (AC) Power: •FL-PS6(C): 120 VAC, 50/60 Hz, 5.0A maximum •FL-PS10(C): 120VAC, 50/60 Hz, 6.2 A maximum •Wire Size: #12-14 AWG with 600 V insulation Command Input Circuit: •Trigger Input Voltage: 9 to 32 VDC •Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 - 16 V) Trouble Contact Rating: 4 A at 24 VDC Output Circuits: • 24 VDC filtered, regulated • FL-PS6: TB8-TB9 – 1A Regulated, 3A special applications; TB10-TB12 – 0.3A Regulated, 3A special applications • FL-PS10: TB8-TB11 – 1.5A Regulated, 3A special applications; TB12-TB14 – 0.3A Regulated, 3A special applications • 6.0 A (FL-PS6) or 10.0 A (FL-PS10) maximum total continuous current for all outputs Secondary Power (Battery) Charging Circuit: • Supports lead-acid batteries only • Float-charge voltage: 27.6 VDC • Maximum current charge: 1.5 A • Maximum battery capacity: 18 AH (inside cabinet) • Maximum battery charging capacity: 33 AH (external cabinet) Physical: •Dimensions: 20.0”H x 14.5”W x 3.5”D (cm: 50.8H x 36.83W x 8.9D) •Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two 18 AH batteries is 39 pounds (17.7 kg) Ordering Information FL-PS6: 6.0 A, 120 VAC remote charger power supply in a lock- able, metal enclosure FL-PS6C: Same as above, ULC-listed model FL-PS10: 10.0 A, 120 VAC remote charger power supply in a lock- able, metal enclosure FL-PS10C: Same as above, ULC-listed model ZNAC-PS: Optional Class A output converter module CMF-300: Addressable Control Module for one Class B or Class A zone of supervised, polarized Notification Appliances. Notification Appliance Circuit option requires external 24 VDC to power notifica- tion appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch MMF-300: Addressable Monitor Module for one zone of normally open dry-contact initiating devices. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Class B or Class A IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- vides two inputs for Class B wiring only CDRM-300: Provides two monitored inputs and two Form-C relays. Functions in Class B wiring only. CMF-300-6: Six-circuit supervised control module CRF-300-6: Six Form-C relay control module EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270-BP: Battery, 12 volt, 7.0 AH, 5-pack (two required). BAT-12180-BP: Battery, 12 volt, 18AH, 2-pack BAT-12330: Battery, 12 volt, 33AH SEISKIT-MULTI-1: Seismic kit for the FL-PS Series. Includes bracket and hardware for two 7AH or two 18AH batteries. DN-60977:A • 4/17/18 — Page 1 of 3 FSP-951 Series Intelligent Plug-In Photoelectric Smoke Detectors Intelligent/Addressable Devices DN-60977:A FSP-951 in B300-6 Base General The NOTIFIER FSP-951 Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combus- tion sources in accordance with more stringent code standards. The FSP-951 Series detector sensitivity can be programmed in the con- trol panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the FSP-951T. The FSP-951R is a remote test capable detector for use with DNR Series duct detector housings. FSP-951 series detec- tors are available for both FlashScan® and CLIP applications as designated. Features • New modern profile for improved aesthetics. • Designed to meet UL268 7th Edition. • Stable communication technique with noise immunity. • Low standby current. • Two-wire SLC connection. • Compatible with FlashScan® and CLIP protocol systems. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). • Optional remote, single-gang LED accessory. • Dual LED design provides 360° viewing angle. • Visible bi-color LEDs blink green every time the detector is addressed, and illuminate steady red on alarm (FlashScan sys- tems only). • Remote test feature from the panel. • Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-1(FlashScan systems only). • Built-in functional test switch activated by external magnet. • Built-in tamper-resistant feature. • Sealed against back pressure. • Expanded color options. • SEMS screws for wiring of the separate base. • Optional relay, isolator, and sounder bases. Specifications Sensitivity: • UL Applications: 0.5% to 4.0% per foot obscuration. • ULC Applications: 0.5% to 3.5% per foot obscuration. Size: 2.0" (5.3 cm) high; base determines diameter. –B300-6: 6.1" (15.6 cm) diameter. –B501: 4" (10.2 cm) diameter. For a complete list of detector bases see DN-60981. Shipping weight: 3.4oz (96.4g) Operating Temperature range: • FSP-951, 0°C to 50°C (32°F to 122°F). • FSP-951T, 0°C to 38°C (32°F to 100°F). • FSP-951R installed in a DNR/DNRW, -20°C to 70°C (-4°F to 158°F). UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts. Relative Humidity: 10%-93% noncondensing. Thermal Ratings: Fixed-temperature setpoint 135°F (57°C). DETECTOR SPACING AND APPLICATIONS NOTIFIER recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at systemsensor.com ELECTRICAL SPECIFICATIONS Voltage Range: 15-32 volts DC peak. Standby Current (max. avg.): 200μA @ 24VDC (one communica- tion every five seconds with LED enabled). LED Current (max.): 4.5mA @ 24 VDC (“ON”). Installation FSP-951 series plug-in detectors use a separate base to simplify installation, service, and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60981. NOTE: 1) Because of inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Style 4 (Class “B”) wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet I56-1380 for device limita- tions between isolator modules and isolator bases. Page 2 of 3 — DN-60977:A • 4/17/18 Agency Listings and Approvals These listings and approvals apply to the detectors specified in this document. In some cases, certain detectors or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC Listed: S911 • FM Approved • CSFM: 7272-0028:0503 Product Line Information NOTE: • Detectors must be mounted to one of the Intelligent Bases listed below. • “A” suffix indicates ULC Listed model. • “IV” suffix indicates FlashScan® and CLIP device. FSP-951: White, low-profile intelligent photoelectric sensor, FlashS- can only. FSP-951A: Same as FSP-951 but with ULC listing. FSP-951-IV: Ivory, low-profile intelligent photoelectric sensor. FSP-951A-IV: Same as FSP-951-IV but with ULC listing. FSP-951T: White, same as FSP-951 but includes a built-in 135°F (57°C) fixed-temperature thermal device. FlashScan only. FSP-951TA: Same as FSP-951T but with ULC listing. FSP-951T-IV: Ivory, same as FSP-951T but includes a built-in 135°F (57°C) fixed-temperature thermal device. FSP-951TA-IV: Same as FSP-951T-IV but with ULC listing. FSP-951R: White, low-profile intelligent photoelectric sensor, remote test capable. For use with DNR/DNRW. FlashScan only. FSP-951RA: Same as FSP-951R but with ULC listing. For use with DNRA. FSP-951R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable. For use with DNR/DNRW. FSP-951RA-IV: Same as FSP-951R-IV but with ULC listing. For use with DNRA. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981 B300-6: White, 6” base, standard flanged low-profile mounting base. B300-6-IV: Ivory,6” base, standard flanged low-profile mounting base. B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6” standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4” standard European flangeless mounting base. UL/ULC listed. B501-BL: Black, 4” standard European flangeless mounting base. UL/ULC listed. B501-IV: Ivory color, 4” standard European flangeless mounting base. UL/ULC listed. B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224BI-WH: White, isolator detector base. B224BI-IV: Ivory isolator detector base. B224BIA-WH: White, isolator detector base, ULC listing. B224BIA-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B210LP(A) base. TR300-IV: Ivory, replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B300(A)- 6. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Page 3 of 3 — DN-60977:A • 4/17/18 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203) 484-7118. www.notifier.com DN-6726:D • 4/13/2012 — Page 1 of 2 NBG-12LX Addressable Manual Pull Station Intelligent/Addressable Devices DN-6726:D • H-240 The NBG-12LX Addressable Manual Pull Station 6 6 4 3 c o v 1 . j p g ‘General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word “ACTIVATED” appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm² wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. • Attractive shape and textured finish. • Key reset. • Includes Braille text on station handle. • Optional trim ring (BG12TR). • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Up to 99 NBG-12LX stations per loop on CLIP protocol loops. • Up to 159 NBG-12LX stations per loop on FlashScan® pro- tocol loops. • Dual-color LED blinks green to indicate normal on FlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications •Shipping Weight: 9.6 oz. (272.15 g) •Normal operating voltage: 24 VDC. •Maximum SLC loop voltage: 28.0 VDC. •Maximum SLC standby current: 375 μA. •Maximum SLC alarm current: 5 mA. •Temperature Range: 32°F to 120°F (0°C to 49°C) •Relative Humidity: 10% to 93% (noncondensing) •For use indoors in a dry location Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word “ACTI- VATED” (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 – 159 on FlashScan® systems, 1 – 99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or Page 2 of 2 — DN-6726:D • 4/13/2012 NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. •UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). •MEA: 67-02-E. •CSFM: 7150-0028:0199. •FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). •BSMI: CI313066760047. • U.S. Coast Guard. • Lloyd’s Register. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. DN-6720:C • 10/06/2010 — Page 1 of 4 FMM-1(A), FMM-101(A), FZM-1(A) & FDM-1(A) Monitor Modules with FlashScan® Intelligent/Addressable Devices DN-6720:C • H-220 General Four different monitor modules are available for Notifier’s intel- ligent control panels for a variety of applications. Monitor mod- ules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1(A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and super- vises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that moni- tors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelli- gent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. FMM-1(A) Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry of address: 01 – 159 on FlashScan loops; 01 – 99 on CLIP loops. • LED flashes green during normal operation (this is a pro- grammable option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 350 μA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FMM-1(A) (Type H) 69 9 9 c o v . j p g Page 2 of 4 — DN-6720:C • 10/06/2010 FMM-101(A) Mini Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the panel. • Powered directly by two-wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • Tinned, stripped leads for ease of wiring. • Direct-dial entry of address: 01 – 159 on FlashScan loops; 01 – 99 on CLIP loops. The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 μA, 1 communication every 5 seconds, 47k EOL; 600 μA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 μA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM-1(A) Interface Module • Supports compatible two-wire smoke detectors. • Supervises IDC wiring and connection of external power source. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct-dial entry of address: 01 – 159 on FlashScan loops, 01 – 99 on CLIP loops. • LED flashes during normal operation; this is a programma- ble option. • LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing sys- tems. FZM-1(A) APPLICATIONS Use the FZM-1(A) to monitor a zone of two-wire smoke detec- tors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resis- tance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms. Average operating current: 300 μA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. 67 2 0 m 1 0 1 . w m f DN-6720:C • 10/06/2010 — Page 3 of 4 FDM1(A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 μA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 μA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm) deep. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two addressable points, starting with the original address. For example, if the FDM-1(A) is set to address “26”, then it will automatically assign itself to addresses “26” and “27”. NOTE: “Ones” addresses on the FDM-1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 sur- face-mount box. Mounting hardware and installation instruc- tions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. •UL: S635 •ULC: S635 • FM Approved •CSFM: 7300-0028:0219 •MEA: 457-99-E •U.S. Coast Guard: –161.002/23/3 (AFP-200: FMM-1/-101, FZM-1) –161.002/42/1 (NFS-640: FMM-1/-101) •Lloyd’s Register: –03/60011/E1 (FMM-1/-101, FZM-1) –94/60004/E2 (AFP-200: except FDM-1) –02/60007 (NFS-640: FDM-1) •FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058 (NFS2-3030) Product Line Information NOTE: “A” suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-101(A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B cir- cuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. !CAUTION: Avoid duplicating addresses on the system. Page 4 of 4 — DN-6720:C • 10/06/2010 FlashScan® and NOTIFIER® are registered trademarks and FireWatch™ is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. L-SERIES LOW FREQUENCY Indoor Selectable Low Frequency Sounders and Sounder Strobes The L-Series offers the most versatile and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry. With white and red plastic housings, listed for wall and ceiling mounting, L-Series Low Frequency can meet virtually any application requirement. The low frequency sounder and low frequency sounder strobes were designed to address the NFPA 72 sleeping space requirements that require a low frequency notification appliance that operates within frequency range of 520 Hz ± 10% and is of a square wave tone. Like the entire L-Series product line they include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, L-Series uses a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, 24-volt operation, and a rotary switch for 520 Hz low frequency sounder tones. Low-frequency models include: • Wall-mount sounder strobes: P2RL-LF, P2WL-LF • Wall-mount sounders: HRL-LF, HWL-LF • Ceiling-mount sounders: HCRL-LF, HCWL-LF • Compact ceiling-mount sounders: HGRL-LF, HGWL-LF FEATURES AND BENEFITS • 520 Hz ± 10% square wave tone, NFPA compliance • Full candela range plus High/Low tone options to optimize current draw for a wide variety of applications • Compact, standard, and round ceiling options • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Rotary switch for High and Low, Temp 3 and Temp 4 settings • Plug-in design with minimal intrusion into the back box • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices, and provides a direct replacement for HW/R-LF and P2R/WH-LF • Compatible with MDL3 sync module • Sounders listed for ceiling and wall mounting • Sounder Strobe listed for wall mounting • Updated modern aesthetics L-Series audible visible notification products have features to maximize profits with lower current draw and modern aesthetics. Page 2 of 4 — 9021-62013:B • 10/2/2019 ARCHITECT/ENGINEER SPECIFICATIONS General L-Series low frequency sounder and low frequency sounder strobes shall mount to a standard 4 × 4 × 1.5-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17/8-inch back box. A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit. Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 24-volt- rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, 185. The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone and have a permanent marking on the housing that reads “low frequency sounder”. Low Frequency Sounder The low frequency sounder shall be a System Sensor L-Series Model _______ listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync•Circuit. MDL3 Module accessory, if used, shall be powered from a notification appliance circuit output and shall operate on a nominal 24 volts (includes fire alarm panels with built in sync). When used with the Sync•Circuit Module MDL3, 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three or temporal four pattern, non-temporal (continuous) pattern and coded supply within the frequency range of 520Hz ± 10% square wave tone. The low frequency sounder shall operate on a coded or non-coded power supply with high and low volume settings. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three or temporal four pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply with high and low volume settings. The field selectable tones will sound within the frequency range of 520 Hz ± 10% square wave tone. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes, the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 411/16 × 411/16 × 21/8-inch back box. The module shall also control two Class B circuits or one Class A circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAL/ELECTRICAL SPECIFICATIONS • Standard Operating Temperature: 32°F to 120°F (0°C to 49°C) • Humidity Range: 10 to 93% non-condensing •Frequency Range: 520 Hz ± 10% • Strobe Flash Rate: 1 flash per second • Nominal Voltage Low Frequency Sounder: Regulated 24 DC/FWR1 • Nominal Voltage Range Low Frequency Sounder Strobe: Regulated 24 VDC/FWR1 • Operating Voltage Range: 16 to 33 V (24 V nominal) • Operating Voltage Range MDL3 Sync Module: 16.5 to 33 V (24 V nominal) • Input Terminal Wire Gauge: 12 to 18 AWG Dimensions • Wall Sounder Strobe Dimensions (including lens): 5.6" L x 4.7" W x 1.9" D (142 mm L x 119 mm W x 49 mm D) • Standard Wall Sounder Dimensions: 5.6" L × 4.7" W × 1.5" D (142 mm L × 119 mm W × 38 mm D) • Compact Wall Sounder Dimensions: 5.25" L x 3.46" W x 1.5" D (133mm L x 88mm W x 38mm D) • Ceiling Sounder Dimensions: 6.8" diameter x 1.4" high (173mm diameter x 36mm high) • Standard Wall Sounder with SBBRL/SBBWL Surface Mount Back Box: 5.7" L x 4.8" W x 3.3" D (145 mm L x 120 mm W x 87 mm D) • Compact Wall Sounder with SBBGRL/SBBGWL Surface Mount Back Box: 5.4" L x 3.6" W x 3.0" D (137 mmL x 91mm W x 76 mm D) • Low Frequency Ceiling Sounder with SBBCRL/SBBCWL Surface Mount Back Box: 6.9" diameter x 3.9" high (175mm diameter x 99mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time- varying power source that is used on some power supply and panel outputs. Page 3 of 4 — 9021-62013:B • 10/2/2019 UL CURRENT DRAW AND SOUND OUTPUT DATA Low Frequency Wall Sounder Strobe Current Draw (mA) and Sound Output (dBA) Pos Tone Volume Setting Current Draw (mA) Sound Output (dBA) 16-33 VDC 16-33 FWR 16-33 V 15cd 30cd 75cd 95cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd DC FWR 1 Temporal 3 High 98 115 158 173 182 212 266 136 153 188 206 228 258 304 80 80 2 Temporal 3 Low 98 102 141 162 173 202 255 150 150 176 194 216 242 280 76 76 3 Temporal 4 High 98 108 137 151 178 202 252 200 198 169 188 212 242 290 80 80 4 Temporal 4 Low 102 104 122 136 163 187 237 176 174 154 173 197 227 275 76 76 5 Continuous High 141 158 198 216 234 264 305 190 207 249 268 289 321 368 80 80 6 Continuous Low 120 128 179 196 215 244 285 165 182 226 244 266 297 342 76 76 UL Max. Low Frequency Sounder Current Draw (mA RMS) Pos Tone Volume Setting Current Draw (mA) Sound Output (dBA) Reverberant 16–33 Volts 16–33 Volts DC FWR DC FWR 1 Temporal 3 High 108 150 80 80 2 Temporal 3 Low 78 76 76 76 3 Temporal 4 High 111 151 80 80 4 Temporal 4 Low 80 76 76 76 5 Continuous High 111 151 80 80 6 Continuous Low 80 76 76 76 7 Coded High 111 151 80 80 8Coded Low 80 76 76 76 *NOTE: For coded tones, temporal coding must be provided by the NAC. If the NAC voltage is held constant, the sounder output will remain constantly on. Coded ratings provided are for continuous voltage. 9021-62013 | B | 10/19 ©2019 Honeywell International Inc. Honeywell Gamewell-FCI 12 Clintonville Road Northford, CT 06472-1610 203.484.7161 www.gamewell-fci.com Gamewell®, Velociti®, and System Sensor® are registered trademarks of and Sync•Circuit™ is a trademark of Honeywell International Inc. ©2019 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of origin: Mexico AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. UL Listed: S4011 FM Approved: PR452768 CSFM: —Horns only: 7135-1653:0516 —Horn/Strobes: 7125-1653:0517 ORDERING INFORMATION P2RL-LF: Low-frequency sounder strobe, wall, red P2WL-LF: Low frequency sounder strobe, wall, white HRL-LF†: Low frequency sounder, wall, red HWL-LF†: Low frequency sounder, wall, white HGRL-LF†: Compact low frequency sounder, wall, red HGWL-LF†: Compact low frequency sounder, wall, white HCRL-LF: Low frequency sounder, ceiling, red HCWL-LF: Low frequency sounder, ceiling, white †Add -BP10 to order bulk pack of 10 units Accessories SBBRL: Surface mount back box, wall, red SBBWL: Surface mount back box, wall, white SBBCRL: Surface mount back box, ceiling, red SBBCWL: Surface mount back box, ceiling, white SBBGRL: Compact surface mount back box, wall, red SBBGWL: Compact surface mount back box, wall, white Agency Listings Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field-selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from –40°F to 151°F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Listed for ceiling or wall mounting SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from −40°F to 151°F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field-selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in-and- out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill holes for screw-in mounting. Plastic and metal weatherproof back boxes come with ¾-inch top and bottom conduit entries and ¾-inch knock-outs at the back. A screw-in NPT plug with an O-ring gasket for a watertight seal is included with each back box. Outdoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. MEA452-05-E3023572 7300-1653:187 (outdoor strobes) 7125-1653:188 (horn strobes, chime strobes) 7135-1653:189 (horns, chimes) S4011 (chimes, horn strobes, horns) S3593 (outdoor and alert strobes) AVDS01201 SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between −40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options shall be set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non-coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature –40°F to 151°F (–40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens)5.6˝ L × 4.7˝ W × 2.5˝ D (142 mm L × 119 mm W × 64 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.3˝ D (142 mm L × 119 mm W × 33 mm D) Wall-Mount Weatherproof Back Box Dimensions (SA-WBB)5.7˝ L × 5.1˝ W × 2.0˝ D (145 mm L × 130 mm W × 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn strobe. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-Temporal High 57 56 69 75 Non-Temporal Medium 42 50 60 69 Non-Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data Horn Tones and Sound Output DataCandela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 Do not use below 32°F15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2012 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS01201 • 3/12 SpectrAlert Advance Diagrams Model Description Wall Horn Strobes P2RK*†2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK*†2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK*†2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK*†2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RK†4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK*†Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK*†Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK*†Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*†Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRK†Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box SpectrAlert Advance Ordering Information Notes: * Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2RK-P. † Add “-R” to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. “Standard cd” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd” refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. 4.7˝ 5.6˝ 6.8˝ Dia. 2.5˝ 2.5˝ Wall-Mount Horn Strobes Wall Plastic Weatherproof Back Box Wall-Mount Horn Strobe with Plastic Weatherproof Back Box