HomeMy WebLinkAboutNick Emery _ 2 Bay Combined For Construction Set _ 9-25-2020GSPublisherVersion 1148.0.46.46 DE T A I L E D DR A F T I N G & DE S I G N Sheet #: DRAWN BY: DCB 435-592-4287 C1.0 Revisions: Dr a w i n g Da t e : 9/25 /20 2 0 Sc a l e : As No t e d Sh e e t Co n t e n t s : CO V E R SH E E T DE T A I L E D DR A F T I N G & DE S I G N EX P R E S S L Y RE S E R V E S IT S CO M M O N LA W CO P Y R I G H T AN D OT H E R PR O P E R T Y RI G H T S IN H E R E N T IN TH E S E PL A N S . AL L DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S AR E IN S T R U M E N T S OF SE R V I C E AN D AR E TH E PR O P E R T Y OF DE T A I L E D DR A F T I N G & DE S I G N AL L IN F O R M A T I O N CO N T A I N E D IN TH E S E S DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S IS PR O J E C T SP E C I F I C AN D SH A L L NO T BE RE P R O D U C E D , DI S C L O S E D , CH A N G E D , OR CO P I E D WI T H O U T FI R S T OB T A I N I N G TH E EX P R E S S WR I T T E N PE R M I S S I O N AN D CO N S E N T OF DE T A I L E D DR A F T I N G & DE S I G N PR E L I M I N A R Y - NO T FO R CO N S T R U C T I O N 55 N 60 0 E, ST GE O R G E , UT 84 7 7 0 WW W .DE T A I L E D D R A F T I N G .CO M NI C K & JE N N A EM E R Y LO T 38 IN TH E PR E S E R V E RE X B U R G , ID A H O NE W 2 BA Y GA R A G E FO R GARAGE 1,582 Sq Ft SQUARE FOOTAGEINDEX OF DRAWINGS SHEET # C1.0 TITLE ROOF & SITE PLAN BUILDING SECTIONS C1.1 C1.2 COVER SHEET IRC SPECS & METHODS IRC SPECS & METHODS A3.0 FLOOR PLAN A1.2 A2.0 EXTERIOR ELEVATIONS A1.0 ELECTRICAL PLANA4.0 SPACES PROVIDED 1BOAT GARAGE SHOP 1 RV GARAGE 1 GSPublisherVersion 1148.0.46.46 DE T A I L E D DR A F T I N G & DE S I G N Sheet #: DRAWN BY: DCB 435-592-4287 C1.1 Revisions: Dr a w i n g Da t e : 9/25 /20 2 0 Sc a l e : As No t e d Sh e e t Co n t e n t s : IR C SP E C S & ME T H O D S DE T A I L E D DR A F T I N G & DE S I G N EX P R E S S L Y RE S E R V E S IT S CO M M O N LA W CO P Y R I G H T AN D OT H E R PR O P E R T Y RI G H T S IN H E R E N T IN TH E S E PL A N S . AL L DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S AR E IN S T R U M E N T S OF SE R V I C E AN D AR E TH E PR O P E R T Y OF DE T A I L E D DR A F T I N G & DE S I G N AL L IN F O R M A T I O N CO N T A I N E D IN TH E S E S DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S IS PR O J E C T SP E C I F I C AN D SH A L L NO T BE RE P R O D U C E D , DI S C L O S E D , CH A N G E D , OR CO P I E D WI T H O U T FI R S T OB T A I N I N G TH E EX P R E S S WR I T T E N PE R M I S S I O N AN D CO N S E N T OF DE T A I L E D DR A F T I N G & DE S I G N PR E L I M I N A R Y - NO T FO R CO N S T R U C T I O N 55 N 60 0 E, ST GE O R G E , UT 84 7 7 0 WW W .DE T A I L E D D R A F T I N G .CO M NI C K & JE N N A EM E R Y LO T 38 IN TH E PR E S E R V E RE X B U R G , ID A H O NE W 2 BA Y GA R A G E FO R IMPORTANT DISCLAIMER IMPORTANT NOTE : THESE NOTES AND SPECIFICATIONS ARE PROVIDED BY THE DESIGNER AS A SERVICE TO THEIR CUSTOMERS TO PROVIDE THE MOST POPULAR CODE TOPICS. THE INFORMATION AND METHODOLOGIES PREPARED HEREIN ARE IN ACCORDANCE TO AND REFERENCED TO THE 2015 INTERNATIONAL RESIDENTIAL CODE . THE INFORMATION IS ALSO A GENERAL SUMMARIZATION OF THE CODE AND IT IS RECOMMENDED THAT YOU BECOME FAMILIAR WITH THE FULL EXTENT OF THE ACTUAL CODE. THE NOTES AND SPECIFICATIONS MAY HAVE TO BE AMENDED DUE TO VARIATIONS IN LOCAL CODES AND GEOLOGICAL CONDITIONS . IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND/OR HOMEOWNER TO MAKE THE NECESSARY MODIFICATIONS TO ENSURE CODE COMPLIANCE AND STRUCTURAL INTEGRITY . IT IS RECOMMENDED THAT YOU CONSULT A LOCAL ARCHITECT OR ENGINEER OF YOUR CHOICE AND CHECK WITH LOCAL BUILDING OFFICIALS PRIOR TO THE START OF ACTUAL CONSTRUCTION . SPECIAL ENGINEERING MAY REQUIRE THAT THESE SPECIFICATIONS BE CHANGED OR AMENDED TO COMPLY WITH SEISMIC, WIND, OR OTHER SPECIAL CONDITIONS AS REQUIRED BY LOCAL CONSTRUCTION METHODOLOGIES AND LOCAL CODES. THE ENCLOSED INFORMATION IS INTENDED TO ASSIST AND INFORM YOU THROUGH THE CONSTRUCTION OF YOUR HOME. YOUR CONSTRUCTION PLANS HAVE BEEN DRAWN TO PRESCRIBE TO INDUSTRY STANDARDS. THESE PROFESSIONAL STANDARDS DETERMINE HOW CONSTRUCTION PLANS ARE DRAWN AND WHAT INFORMATION THEY INCLUDE . CONSTRUCTION PLANS ARE INTENDED AS A TECHNICAL GUIDE TO PROFESSIONAL CONTRACTORS AND ARE NOT INTENDED TO BE A SET OF STEP-BY-STEP INSTRUCTIONS. THEREFORE, IF YOU ARE PLANNING TO BUILD TO YOUR HOME WITHOUT THE SERVICES OF PROFESSIONAL BUILDER. WE SUGGEST THAT YOU BECOME THOROUGHLY FAMILIAR WITH READING CONSTRUCTION PLANS OR CONSIDER CONSULTING A CONSTRUCTION SPECIALIST. GREAT CARE AND EFFORT GOES INTO THE CREATION OF THE DESIGN AND DRAFTING OF YOUR CONSTRUCTION PLANS. HOWEVER, BECAUSE OF THE IMPOSSIBILITY OF PROVIDING ANY PERSONAL AND/OR "ON-SITE" CONSULTATION, SUPERVISION, CONTROL OVER THE ACTUAL CONSTRUCTION, AND BECAUSE OF THE GREAT VARIANCES IN LOCAL BUILDING CODE REQUIREMENTS AND OTHER LOCAL BUILDING AND WEATHER CONDITIONS , OUR COMPANY NOR THEIR AGENTS OR EMPLOYEES, ASSUMES NO RESPONSIBILITY FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO, ANY DEFICIENCIES, OMISSIONS, OR ERRORS IN THE DESIGN. IN THE DIMENSION, AND/OR DRAWINGS CONTAINED IN THE CONTRACTION. PROCEEDING WITH CONSTRUCTION CONSTITUTES THE ACCEPTANCE OF THE CONSTRUCTION DOCUMENTS AS "AS IS" AND ANY DISCREPANCIES, ERRORS AND/OR OMISSIONS BECOME THE SOLE RESPONSIBILITY OF THE PURCHASER. IF ANY ERRORS ARE DISCOVERED PRIOR TO CONSTRUCTION, THE DESIGNER WILL BE GIVEN FULL OPPORTUNITY TO CORRECT ANY ERRORS AND/OR OMISSIONS TO THE CONSTRUCTION PLANS. IN ANY OR ALL CIRCUMSTANCES. THE MAXIMUM FINANCIAL LIABILITY TO THE DESIGNER CAN NOT EXCEED THE TOTAL PLAN PURCHASE. PROFESSIONAL SEAL THOUGH EVERY EFFORT WAS MADE TO MAKE THE CONSTRUCTION DOCUMENTS FOLLOW THE CURRENT I.R.C NATIONAL CODE METHODOLOGIES, A FEW STATES AND CITIES HAVE PASSED BI- LAWS REGARDING CONSTRUCTION PLANS THAT WOULD BE SUBMITTED TO YOUR LOCAL MUNICIPALITY AND USED FOR THE CONSTRUCTION OF YOUR HOME. THESE BI-LAWS REQUIRE THE CONSTRUCTION PLANS BE REVIEWED AND/OR PREPARED, INSPECTED, AND SEALED (OR STAMPED) BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT IN YOUR STATE. IT IS ADVISED THAT YOU CONTACT YOUR MUNICIPALITY'S BUILDING DEPARTMENT FOR INSTRUCTIONS TO COMPLY WITH THEIR CONSTRUCTION PLAN REVIEW PROCESS. COPYRIGHTS REPRODUCTION OF THESE CONSTRUCTION PLANS, EITHER IN WHOLE OR IN PART, INCLUDING ANY FORM OF COPYING AND/OR PREPARATION OF A DERIVATIVE WORKS THEREOF , FOR ANY REASON IS STRICTLY PROHIBITED . THE PURCHASE OF A SET OF CONSTRUCTION PLANS IN NO WAY TRANSFERS ANY COPYRIGHT OR OTHER OWNERSHIP INTEREST IN IT TO THE PURCHASER EXCEPT FOR A LIMITED LICENSING RELEASE TO USE THE SAID PLAN SET FOR PURPOSE OF CONSTRUCTING ONE, AND ONLY ONE, DWELLING UNIT. THE PURCHASE OF ADDITIONAL SETS OF THE SAID PLANS AT A REDUCED PRICE FROM THE ORIGINAL SET OR AS PART OF A MULTIPLE SET PACKAGE DOES NOT CONVEY TO THE PURCHASER A LICENSE TO CONSTRUCT MORE THAN ONE DWELLING. SIMILARLY, THE PURCHASE OF REPRODUCIBLE CONSTRUCTION PLANS (A.K.A. SEPIAS, MYLARS, OR VELLUMS) CARRIES THE SAME COPYRIGHT PROTECTION AS MENTIONED ABOVE. IT IS GENERALLY ALLOWED TO MAKE ADDITIONAL COPIES FOR THE CONSTRUCTION OF A SINGLE DWELLING ONLY. TO USE ANY PLAN MORE THAN ONCE. AND TO AVOID ANY COPYRIGHT / LICENSE INFRINGEMENT, IT IS NECESSARY TO CONTACT PLAN SOURCE TO RECEIVE A RELEASE AND LICENSE FOR ANY EXTENDED USAGE. WHEREAS A PURCHASER OF REPRODUCIBLE'S IS GRANTED A LICENSE TO MAKE COPIES, IT SHOULD BE NOTED THAT AS COPYRIGHTED MATERIALS, MAKING PHOTOCOPIES FROM CONSTRUCTION PLANS IS ILLEGAL. COPYRIGHT AND LICENSING OF CONSTRUCTION PLANS EXIST TO PROTECT ALL PARTIES. IT RESPECTS AND SUPPORTS THE INTELLECTUAL PROPERTY OF THE ORIGINAL ARCHITECT AND DESIGNER, THEREBY KEEPING IT POSSIBLE TO OFFER PREDRAWN PLANS AT AFFORDABLE PRICES . COPYRIGHT LAW FOR PREDRAWN CONSTRUCTION PLANS IS NOW BEING VIGOROUSLY ENFORCED. GENERAL SITE NOTES 1. CONTRACTOR TO VERIFY LOCATIONS OF SITE UTILITIES , REQUIREMENTS AND CONNECTIONS FEES. OWNER, CONTRACTOR, AND SUB-CONTRACTORS TO PAY ALL THEIR RELATED CONSTRUCTION PERMIT FEES AS AGREED UPON BETWEEN THE OWNER AND CONTRACTOR. 2. BEFORE EXCAVATION, THE CONTRACTOR SHALL EXAMINE ALL DRAWINGS, MAPS, AND BUILDING SITE OF EXISTING FACILITY TO DETERMINE THE ROUTES OF ALL UNDERGROUND UTILITIES. BEFORE DIGGING COMMENCES IT IS ADVISED THAT THE OWNER OR CONTRACTOR CALLS THEIR STATES UTILITY LOCATER FACILITATOR. 3. IT IS RECOMMENDED THAT THE SITES SOIL BE TESTED FOR COMPRESSION RATING TO DETERMINE FOUNDATION AND FOOTING DESIGN. CONCRETE FOUNDATIONS AND FOOTING DESIGN SHALL BE ACCORDANCE TO CHAPTER 4 OF THE I.R.C CODE. SEE FOUNDATION SECTION ON THIS PAGE FOR MORE DETAIL. 4. CONSULT A LOCAL CIVIL ENGINEER FOR SITE PLANS AND SURVEYS OF EXISTING PROPERTY. A LANDSCAPE ARCHITECT SHOULD BE CONSULTED FOR MORE EXTENSIVE SITE LANDSCAPE DESIGNS. I.R.C BUILDING PLANNING - CHAPTER 3 GLAZING R308 R308.4 HAZARDOUS LOCATIONS GLAZING IN THE FOLLOWING LOCATIONS SHALL BE OF SAFETY GLAZING CONFORMING TO THE HUMAN IMPACT LOADS OF SECTION R308.3 (SEE EXCEPTIONS). 1. SWINGING DOORS EXCEPT JALOUSIES. 2. FIXED AND OPERABLE PANELS OF SWINGING , SLIDING AND BIFOLD DOOR ASSEMBLIES 3. STORM DOORS 4. UNFRAMED SWINGING DOORS 5. DOORS AND ENCLOSURES FOR HOT TUB, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS AND IN ANY PORTION OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 6. FIXED OR OPERABLE VERTICAL PANELS ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN A 24-INCH ARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE. 7. INDIVIDUAL FIXED OR OPERABLE PANEL, OTHER THAN THOSE DESCRIBED IN ITEMS 5 AND 6 ABOVE. THAT MEET ALL OF THE FOLLOWING CONDITIONS : 8. RAILING REGARDLESS OF AREA OR HEIGHT ABOVE A WALKING SURFACE INCLUDING STRUCTURED BALUSTER PANELS AND NONSTRUCTURAL IN-FILL PANELS. 9. WALLS AND FENCES USED AS THE BARRIER FOR INDOOR AND OUTDOOR SWIMMING POOLS ,HOT TUBS AND SPAS WHEN : 60 INCHES ABOVE A WALKING SURFACE AND 60 INCHES HORIZONTALLY OF THE WATER'S EDGE.(THIS SHALL APPLY TO SINGLE GLAZING AND ALL PANELS IN MULTIPLE GLAZING) 10. GLAZING ADJACENT TO STAIRWAYS,LANDINGS, AND APPROVED RAMPS WITHIN 36 INCHES HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. 11. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES ABOVE THE NOSE OF THE TREAD. MISC. A.I SKYLIGHT AND SLOPED GLAZING SHALL COMPLY WITH SECTION R308.6 B.I SITE BUILT WINDOWS SHALL COMPLY WITH SECTION R308.5 C.I EXTERIOR WINDOWS AND GLASS DOORS SHALL CONFORM TO THE PROVISIONS OF SECTION R 613 AND THE FOLLOWING : RESIST THE DESIGN WIND LOADS SPECIFIED IN TABLE R301.2(2) AND ADJUSTED FOR HEIGHT AND EXPOSURE PER TABLE R301.2(3) (SECTION R613.2) D.I WINDOWS AND GLASS DOORS SHALL BE ANCHORED IN ACCORDANCE WITH THE PUBLISHED MANUFACTURER'S RECOMMENDATIONS. (SECTION R613.5.1) H.I ANCHORAGE OF EXTERIOR WINDOWS SHALL CONFORM TO SECTION R613.5.2 EMERGENCY ESCAPE AND RESCUE OPENING R310 R310 EMERGENCY ESCAPE RESCUE OPENINGS BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY AND RESCUE OPENING. SUCH OPENING SHALL OPEN DIRECTLY INTO A PUBLIC STREET, PUBLIC ALLEY, YARD OR COURT . WHERE BASEMENTS CONTAIN ONE OR MORE SLEEPING ROOMS, EMERGENCY EGRESS AND RESCUE OPENINGS SHALL BE REQUIRED IN EACH SLEEPING ROOM. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES ABOVE THE FLOOR. WHERE A DOOR OPENING HAVING A THRESHOLD BELOW THE ADJACENT GROUND ELEVATION SERVES AS AN EMERGENCY ESCAPE AND RESCUE OPENING AND IS PROVIDED WITH A BULKHEAD ENCLOSURE, THE BULKHEAD ENCLOSURE SHALL COMPLY WITH SECTION R310.3. THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENINGS FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED SILL HEIGHT BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION R310.2. EMERGENCY ESCAPE AND RESCUE SHALL OPEN DIRECTLY INTO A PUBLIC WAY. OR TO A YARD OR COURT THAT OPENS TO A PUBLIC WAY. MEANS OF EGRESS 311 R311 MEANS OF EGRESS STAIRWAYS, RAMPS, EXTERIOR EXIT BALCONIES, HALLWAYS AND DOORS SHALL COMPLY WITH SECTION R311: 1. STAIRWAY WIDTH SHALL NOT BE LESS THAN 36" IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT AND BELOW THE REQUIRED HEADROOM HEIGHT. (R311.7.1) 2. THE MINIMUM HEADROOM IN ALL PARTS OF THE STAIRWAY SHALL NOT BE LESS THAN 6'-8". (R311.7.2) 3. THE MAXIMUM RISER HEIGHT SHALL BE 7 3 /4 ". (R311.7.5.1) 4. THE MINIMUM TREAD DEPTH SHALL BE 10". WINDER TREADS SHALL HAVE A MINIMUM TREAD DEPTH OF 6". (R311.7.5.2) SMOKE ALARMS R314 R314.3 LOCATION SINGLE- AND MULTIPLE-STATION SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: 1. EACH SLEEPING ROOM R314.3 LOCATION - CONTINUED 2. OUTSIDE OF EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS 3. ON EACH ADDITIONAL STORY OF THE DWELLING , INCLUDING BASEMENTS, CELLARS AND HABITABLE ATTICS BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN THE ADJACENT LEVELS. A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL STORY BELOW THE UPPER LEVEL. WHEN ONE OR MORE SMOKE ALARMS IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. BUILDINGS AND STRUCTURES CONSTRUCTED IN WHOLE OR IN PART IN FLOOD HAZARD AREAS (INCLUDING A OR V ZONES) AS ESTABLISHED IN TABLE R301.2 (1) SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS CONTAINED IN THIS SECTION R322.1 GENERAL R322.1.2 STRUCTURAL SYSTEMS ALL STRUCTURAL SYSTEMS OF ALL BUILDING AND STRUCTURES SHALL BE DESIGNED, CONNECTED AND ANCHORED TO RESIST FLOTATION, COLLAPSE, OR PERMANENT LATERAL MOVEMENT DUE TO STRUCTURAL LOADS AND STRESSES FROM FLOODING EQUAL TO THE DESIGN FLOOD ELEVATION. R322.1.4 ESTABLISHING THE DESIGN FLOOD ELEVATION THE DESIGN FLOOD ELEVATION SHALL BE USED TO DEFINE AREAS PRONE TO FLOODING, AND SHALL DESCRIBE. AT A MINIMUM . THE BASE FLOOD ELEVATION AT THE DEPTH OF PEAK ELEVATION OF FLOODING (INCLUDING WAVE HEIGHT ) WHICH HAS A 1 PERCENT OR GREATER CHANCE OF BEING EQUALED TO EXCEEDED IN ANY GIVEN YEAR. FOR DETERMINING DESIGN FLOOD ELEVATIONS AND IMPACTS REFER TO SECTION R322.1.4.1 AND R322.1.4.2 R322.1.6 PROTECTION OF MECHANICAL AND ELECTRICAL SYSTEMS ELECTRICAL SYSTEMS. EQUIPMENT AND COMPONENTS, AND HEATING, VENTILATING, AIR CONDITIONING, AND PLUMBING APPLICATIONS. PLUMBING FIXTURES, DUCT SYSTEMS, AND OTHER SERVICE EQUIPMENT SHALL BE LOCATED AT OR ABOVE THE DESIGN FLOOD ELEVATION. REVIEW EXCEPTIONS R322.1.6 ENCLOSED AREAS, INCLUDING CRAWL SPACES, THAT ARE BELOW THE DESIGN FLOOD ELEVATION SHALL: 1. BE USED SOLELY FOR PARKING OF VEHICLES , BUILDING ACCESS OR STORAGE. 2. BE PROVIDED WITHFLOOD OPENING THAT MEET THE FOLLOWING CRITERIA: R322.2.2 ENCLOSED AREA BELOW DESIGN FLOOD ELEVATION A. THERE SHALL BE A MINIMUM OF TWO OPENINGS ON DIFFERENT SIDES OF EACH ENCLOSED AREA: IF ANY BUILDING HAS MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOOD ELEVATION, EACH AREA SHALL HAVE OPENINGS ON EXTERIOR WALLS. B. THE TOTAL NET AREA OF ALL OPENINGS SHALL BE AT LEAST 1 SQUARE INCH FOR EACH SQUARE FOOT OF ENCLOSED AREA, OR THE OPENINGS SHALL BE DESIGNED AND THE CONSTRUCTION DOCUMENTERS SHALL INCLUDE A STATEMENT THAT THE DESIGN AND INSTALLATION WILL PROVIDE FOR EQUALIZATION OF HYDROSTATIC FLOOD FORCES ON EXTERIOR WALLS BY ALLOWING FOR AUTOMATIC ENTRY AND EXIT OF FLOODWATERS. C. THE BOTTOM OF EACH OPENING SHALL BE 1 FOOT OR LESS ABOVE THE ADJACENT GROUND LEVEL. D. OPENING SHALL BEAT LEAST 3 INCHES IN DIAMETER. E. ANY LOVERS, SCREENS, OR OTHER OPENING COVERS SHALL ALLOW THE AUTOMATIC FLOW OF FLOOD WATERS INTO AND OUT OF THE ENCLOSED AREA. F. OPENINGS INSTALLED IN DOORS AND WINDOWS , THAT MEET REQUIREMENTS A-E ARE ACCEPTABLE; HOWEVER, DOORS AND WINDOWS WITHOUT INSTALLED OPENINGS DO NOT MEET THE REQUIREMENTS OF THE SECTION. I.R.C. FOUNDATION - CHAPTER 4 GENERAL R401 R401 .2 REQUIREMENTS FOUNDATION CONSTRUCTION SHALL BE CAPABLE OF ACCOMMODATING ALL LOADS ACCORDING TO SECTION R301 AND OF TRANSMITTING THE RESULTING LOADS TO THE SUPPORTING SOIL. FILL SOILS THAT SUPPORT FOOTINGS AND FOUNDATIONS SHALL BE DESIGNED. INSTALLED, AND TESTED IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICES. GRAVEL FILL USED AS FOOTINGS FOR WOOD AND PRECAST FOUNDATIONS SHALL COMPLY WITH SECTION R403. R401 .3 DRAINAGE SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 INCHES WITHIN THE FIRST 10 FEET. R401.4 SOIL TESTS IN AREAS LIKELY TO HAVE EXPANSIVE. COMPRESSIBLE, SHIFTING OR OTHER UNKNOWN SOIL CHARACTERISTICS. THE BUILDING OFFICIAL SHALL DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE THE SOILS CHARACTERISTIC AT A PARTICULAR LOCATION. THIS TEST SHALL BE MADE BY AN APPROVED AGENCY USING AN APPROVED METHOD. CONTRACTOR TO REFER TO TABLE R401.14.1 FOR PRESUMPTIVE LOAD - BEARING VALVES OF FOUNDATION MATERIALS. MATERIALS R402 R402.1. WOOD FOUNDATIONSS WOOD FOUNDATION SYSTEMS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE PROVISION OF THIS CODE. R402.1.1 FASTENERS FASTENERS USED BELOW APPROXIMATE GRADE (OR USED IN KNEE WALL CONSTRUCTION) SHALL BE OF TYPE 304 OR 316 STAINLESS STEEL. FASTENERS USED ABOVE APPROXIMATE GRADE SHALL BE OF TYPE 304 OR 316 STAINLESS STEEL , SILICON BRONZE, COPPER, HOT-DIPPED GALVANIZED (ZINC COATED) STEEL NAILS. OR HOT TUMBLED GALVANIZED (ZINC COATED) STEEL NAILS. ELECTROGALVANIZED STEEL NAILS AND GALVANIZED (ZINC COATED) STEEL STAPLES SHALL NOT BE PERMITTED. R402.1.2 WOOD TREATMENT ALL LUMBER AND PLYWOOD SHALL BE TREATED IN ACCORDANCE WITH AWPA U1 AND BEAR THE LABEL OF AN ACCREDITED AGENCY. R402.2 CONCRETE CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH AS SHOWN IN TABLE R402.2 (SECTION R402.2) CONCRETE SUBJECT TO WEATHERING (TABLE R301.2(1) SHALL BE AIR ENTRAINED AS SPECIFIED IN TABLE R402.2 (SECTION R402.2) CONCRETE MIXTURES FOR GARAGE AND SUPPORT SLABS AND EXTERIOR LOCATIONS THAT WILL BE EXPOSED TO DEICING CHEMICALS SHALL NOT HAVE MAXIMUM WEIGHT OF FLY ASH, SILICA FUME, SLAG OR OTHER POZZOLANS THAT EXCEED THE PERCENTAGE OF TOTAL WEIGHT OF CEMENTITIOUS MATERIALS SPECIFIED IN SECTION 4.2.3. OF ACI 318. MATERIALS USED TO PRODUCE CONCRETE AND TESTING THEREOF SHALL COMPLY WITH THE APPLICABLE STANDARDS LISTED IN CHAPTER 3 OF ACI 318. FOOTINGS R403 ALL EXTERIOR WALLS SHALL BE SUPPORTED ON CONTINUOUS SOLID OR FULLY GROUTED MASONRY OR CONCRETE FOOTINGS , CRUSHED STONE FOOTINGS, WOOD FOUNDATIONS OR OTHER APPROVED STRUCTURAL SYSTEMS. R403.1.1 MINIMUM SIZE MINIMUM SIZE FOR CONCRETE AND MASONRY FOOTINGS SHALL BE AS SET FORTH IN TABLE R403.1 AND FIGURE R403.1(1) SPREAD FOOTING SHALL BE AT LEAST 6 INCHES IN THICKNESS. FOOTING PROJECTIONS SHALL BE AT LEAST 2 INCHES AND SHALL NOT EXCEED THE THICKNESS OF THE FOOTINGS. THE SIZE OF THE FOOTINGS SUPPORTING PIERS AND COLUMNS SHALL BE IN ACCORDANCE WITH TABLE R401.4.1 FOOTINGS FOR WOOD FOUNDATIONS SHALL BE IN ACCORDANCE WITH THE DETAILS SET FORTH IN SECTION R403.2 AND FIGURES R403.1(2) AND R403.1(3). R403.1.2 CONTINUOUS FOOTING IN SEISMIC DESIGN CATEGORIES D0. D1. AND D2 THE BRACED WALL PANELS AT EXTERIOR WALLS OF ALL BUILDINGS AND ALL REQUIRED INTERIOR BRACED WALL PANELS IN BUILDINGS WITH PLAN DIMENSIONS GREATER THAN 50 FEET IN SEISMIC DESIGN CATEGORIES D0, D1, AND D2 SHALL BE SUPPORTED BY CONTINUOUS FOOTINGS. R403.1.3 SEISMIC REINFORCING CONCRETE FOOTINGS LOCATED IN SEISMIC DESIGN CATEGORIES D0,D1,AND D2 AS ESTABLISHED IN TABLE R301.2(1) SHALL HAVE MINIMUM REINFORCEMENT SET FORTH IN THIS SECTION FOR CONSTRUCTION JOINTS CREATED BETWEEN A CONCRETE FOOTING AND A STEM WALL, WHERE A GROUTED MASONRY STEM WALL IS SUPPORTED ON A CONCRETE FOOTING AND STEM WALL. AND WHEN MASONRY STEM WALLS WITHOUT SOLID GROUT AND VERTICAL REINFORCEMENT ARE NOT PERMITTED R403.1.4 MINIMUM DEPTH ALL EXTERIOR FOUNDATIONS SHALL BE PLACED AT LEAST 12 INCHES BELOW UNDISTURBED GROUND. WHERE APPLICABLE, THE DEPTH OF FOOTINGS SHALL ALSO CONFORM TO SECTIONS R403.1.4.1 THROUGH R403.1.4.2. EXCEPT FOR FROST- PROTECTED FOOTINGS, PERMANENT SUPPORT SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION R403.3. INSEISMIC DESIGN CATEGORIES D0,D1 AND D2, INTERIOR FOOTINGS SUPPORTING BEARING OR BRACING WALLS AND CAST MONOLITHICALLY WITH A SLAB ON APPROXIMATE GRADE SHALL EXTEND TO A DEPTH OF NOT LESS THAN 12 INCHES BELOW THE TOP OF THE SLAB-SECTION R403.1.4.2 R403.1.5 SLOPE FOOTINGS SHALL BE STEPPED WHERE IT IS NECESSARY TO CHANGE THE ELEVATION OF THE TOP SURFACE OF THE FOOTINGS OR WHERE THE SLOPE OF THE BOTTOM SURFACE OF THE FOOTING EXCEEDS ONE UNIT VERTICAL IN TEN UNITS HORIZONTAL (10-PERCENT SLOPE) R403.1.6 FOUNDATION ANCHORAGE THE WOOD SOLE PLATE AT EXTERIOR WALLS ON MONOLITHIC SLABS AND WOOD SILL PLATE SHALL BE ANCHORED TO THE FOUNDATION WITH ANCHOR BOLTS SPACED A MAX. OF 6 FEET ON CENTER. THERE SHALL BE A MINIMUM OF TWO BOLTS PER PLATE SECTION. IN SEISMIC DESIGN CATEGORIES D0,D1,AND D2. ANCHOR BOLTS SHALL BE SPACED 6 FEET ON CENTER AND LOCATED WITHIN 12 INCHES OF THE ENDS OF EACH PLATE 2015 INTERNATIONAL RESIDENTIAL CODE CONSTRUCTION SPECIFICATIONS AND METHODOLOGIES 3.5PER SECTION R324.3.5 ENCLOSED AREAS BELOW THE DESIGN FLOOD ELEVATION SHALL BE USED SOLELY FOR PARKING OR VEHICLES, BUILDING ACCESS OR STORAGE. R403.1 GENERAL FLOOD-RESISTANT CONSTRUCTION R322 GSPublisherVersion 1148.0.46.46 DE T A I L E D DR A F T I N G & DE S I G N Sheet #: DRAWN BY: DCB 435-592-4287 C1.2 Revisions: Dr a w i n g Da t e : 9/25 /20 2 0 Sc a l e : As No t e d Sh e e t Co n t e n t s : IR C SP E C S & ME T H O D S DE T A I L E D DR A F T I N G & DE S I G N EX P R E S S L Y RE S E R V E S IT S CO M M O N LA W CO P Y R I G H T AN D OT H E R PR O P E R T Y RI G H T S IN H E R E N T IN TH E S E PL A N S . AL L DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S AR E IN S T R U M E N T S OF SE R V I C E AN D AR E TH E PR O P E R T Y OF DE T A I L E D DR A F T I N G & DE S I G N AL L IN F O R M A T I O N CO N T A I N E D IN TH E S E S DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S IS PR O J E C T SP E C I F I C AN D SH A L L NO T BE RE P R O D U C E D , DI S C L O S E D , CH A N G E D , OR CO P I E D WI T H O U T FI R S T OB T A I N I N G TH E EX P R E S S WR I T T E N PE R M I S S I O N AN D CO N S E N T OF DE T A I L E D DR A F T I N G & DE S I G N PR E L I M I N A R Y - NO T FO R CO N S T R U C T I O N 55 N 60 0 E, ST GE O R G E , UT 84 7 7 0 WW W .DE T A I L E D D R A F T I N G .CO M NI C K & JE N N A EM E R Y LO T 38 IN TH E PR E S E R V E RE X B U R G , ID A H O NE W 2 BA Y GA R A G E FO R SECTION AT INTERIOR BRACED WALL LINES WHEN REQUIRED BY SECTION R602.10.9 TO BE SUPPORTED ON A CONTINUOUS FOUNDATION. BOLTS SHALL BE AT LEAST 1/2 INCH IN DIAMETER AND SHALL EXTEND A MINIMUM OF 7 INCHES IN TO MASONRY OR CONCRETE. INTERIOR BEARING WALL SOLE PLATES ON MONOLITHIC SLAB FOUNDATION SHALL BE POSITIVELY ANCHORED WITH APPROVED FASTENERS A NOT AND WASHER SHALL BE TIGHTENED ON EACH BOLT OF THE PLATE. SILLS AND SOLE PLATES SHALL BE PROTECTED AGAINST DECAY AND TERMITES WHERE REQUIRED BY SECTION R317 AND R318. COLD-FORMED STEEL FRAMING SYSTEMS SHALL BE FASTENED TO THE WOOD SILL PLATES OR ANCHORED DIRECTLY TO THE FOUNDATION AS REQUIRED IN SECTION R505.3.1 OR R603.3.1. NOTE: CONSULT SECTION R403.1.6 FOR EXCEPTIONS AND SECTION R403.1.6.1 ANCHORAGE METHODOLOGIES IN SEISMIC DESIGN CATEGORIES C (LIGHT- FRAME TOWNHOUSES. D0. D1. AND D2. R403.1.6 FOUNDATION ANCHORAGE - CONTINUE R403.1.7 FOOTINGS ON OR ADJACENT TO SLOPES THE PLACEMENT OF BUILDINGS AND STRUCTURES ON OR ADJACENT TO SLOPES STEEPER THAN I UNIT VERTICAL IN 3 UNITS HORIZONTAL (33.3 PERCENT SLOPE) SHALL CONFORM TO SECTIONS R403.1.7.1 THROUGH R403.1.7.4. R403.1.8 FOUNDATIONS ON EXPANSIVE SOILS FOUNDATIONS AND FLOOR SLABS FOR BUILDINGS LOCATED ON EXPANSIVE SOILS SHALL BE DESIGNED IN ACCORDANCE WITH SECTION 1808.6 OF THE INTERNATIONAL BUILDING CODE. EXCEPTIONS: SLAB-ON-GROUND AND OTHER FOUNDATIONS SYSTEMS WHICH HAVE PERFORMED ADEQUATELY IN SOIL CONDITIONS SIMILAR TO THOSE ENCOUNTERED AT THE BUILDING SITE ARE PERMITTED SUBJECT TO THE APPROVAL OF THE BUILDING OFFICIAL. EXPANSIVE SOILS SHALL BE DETERMINED PER SECTION R403.1.8.1 R403.2 FOOTINGS FOR WOOD FOUNDATIONS FOOTINGS FOR WOOD FOUNDATIONS SHALL BE IN ACCORDANCE WITH FIGURES R403.1(2) AND R403.1(3) AND HAVE A BASE AS DESCRIBED IN THIS SECTION. R404.1 CONCRETE AND MASONRY FOUNDATION WALLS FOR BUILDINGS WHERE THE MONTHLY MEAN TEMPERATURE OF THE BUILDING IS MAINTAINED AT A MINIMUM OF 64 DEG. FOOTINGS ARE NOT REQUIRED TO EXTEND BELOW THE FROST LINE WHEN PROTECTED FROM FROST BY INSULATION IN ACCORDANCE WITH FIGURE R403.3(1) AND TABLE R403.3(1). FOUNDATIONS PROTECTED FROM FROST IN ACCORDANCE TO SAID FIGURES AND TABLES SHALL NOT BE USED FOR UNHEATED SPACES SUCH AS PORCHES . UTILITY ROOM. GARAGES. AND CARPORTS. AND SHALL NOT BE ATTACHED TO BASEMENTS OR CRAWL SPACES THAT ARE NOT MAINTAINED AT A MINIMUM MONTHLY MEAN TEMPERATURE OF 64 DEGREES FAHRENHEIT. FOUNDATION AND RETAINING WALLS R404 R403.3 FROST PROTECTED SHALLOW FOUNDATIONS FOUNDATION DRAINAGE R405 R405.1 CONCRETE OR MASONRY FOUNDATIONS DRAINS SHALL BE PROVIDED AROUND ALL CONCRETE OR MASONRY FOUNDATIONS THAT RETAIN EARTH AND ENCLOSE HABITABLE OR USABLE SPACES LOCATED BELOW GRADE. DRAINAGE TILES, GRAVEL OR CRUSHED STONE DRAINS. PERFORATED PIPE OR OTHER APPROVED SYSTEMS OR MATERIALS SHALL BE INSTALLED AT OR BELOW THE AREA TO BE PROTECTED AND SHALL DISCHARGE BY GRAVITY OR MECHANICAL MEANS INTO AN APPROVED DRAINAGE SYSTEM GRAVEL OR CRUSHED STONE- R405.1 CONCRETE OR MASONRY FOUNDATIONS- CONTINUE DRAINS SHALL EXTEND AT LEAST I FOOT BEYOND THE OUTSIDE EDGE OF THE FOOTING AND 6 INCHES ABOVE THE TOP OF THE FOOTING AND BE COVERED WITH AN APPROVED FILTER MEMBRANE MATERIAL. THE TOP OF THE OPEN JOINTS OF DRAIN TILES SHALL BE PROTECTED WITH STRIPS OF BUILDING PAPER. DRAINAGE TILES OR PERFORATED PIPE SHALL BE PLACED ON A MINIMUM OF 2 INCHES OF WASHED GRAVEL OR CRUSHED ROCK AT LEAST ONE SIEVE SIZE LARGER THAN THE TILE JOINT OPENING OR PERFORATION AND COVERED NOT LESS THAN 6 INCHES OF THE SAME MATERIAL. OTHER THAN GROUP I SOILS, A SUMP SHALL BE PROVIDED TO DRAIN THE POROUS LAYER AND FOOTINGS . AND SHALL COMPLY WITH SECTION R405.2.3. FOUNDATION WATERPROOFING AND DAMPPROOFING R406 R406.2 CONCRETE OR MASONRY FOUNDATION WATERPROOFING 1. FOUNDATION WALL WATERPROOFING SHALL BE WITH A MEMBRANE EXTENDING FROM THE TOP OF THE FOOTING TO THE FINISHED GRADE, WITH MATERIALS AS SPECIFIED IN SECTION R406.2. EXCEPT WHERE REQUIRED TO BE WATERPROOFED. FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE HABITABLE OR USABLE SPACES LOCATED BELOW APPROXIMATE GRADE SHALL BE DAMPPROOFED . 2. IN AREAS WHERE HIGH WATER TABLE OR OTHER SEVERE SOIL- WATER CONDITIONS ARE KNOWN TO EXIST. EXTERIOR FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE HABITABLE OR USABLE SPACE LOCATED BELOW APPROXIMATE GRADE SHALL BE WATERPROOFED PER SECTION R406.2. 3. DAMPPROOFING, WHERE REQUIRED, SHALL BE INSTALLED WITH MATERIALS AND AS REQUIRED IN SECTION R406.1. UNDER-FLOOR SPACE R408 R408.1 VENTILATION R408.2 OPENINGS FOR UNDER-FLOOR VENTILATION VENTILATION OPENINGS SHALL BE COVERED FOR THE HEIGHT AND WIDTH WITH AN APPROVED MATERIAL LISTED IN THIS SECTION. R408.4 ACCESS AN ACCESS OPENING 18 INCHES BY 24 INCHES SHALL BE PROVIDED TO THE UNDER FLOOR SPACE. ACCESS OPENINGS TO UNDERFLOOR SPACES WHERE MECHANICAL EQUIPMENT IS LOCATED SHALL BE PROVIDED IN ACCORDANCE WITH SECTION MI305.1.4. R408.7 FLOOD RESISTANCE FOR BUILDINGS LOCATED IN FLOOD HAZARD AREAS AS ESTABLISHED IN TABLE R301.2(1) 1. WALLS ENCLOSING THE UNDER - FLOOR SPACE SHALL BE PROVIDED WITH FLOOD OPENINGS IN ACCORDANCE WITH SECTION R322.2.2. 2. THE FINISHED GROUND LEVEL OF THE UNDER-FLOOR SPACE SHALL BE EQUAL TO OR HIGHER THAN THE OUTSIDE FINISHED GROUND LEVEL. EXCEPTIONS: UNDER-FLOOR SPACES THAT MEET THE REQUIREMENTS OF FEMA/FIA TB 11-1. I.R.C. FLOORS - CHAPTER 5 R501.2 REQUIREMENTS GENERAL R501 FLOOR CONSTRUCTION SHALL BE CAPABLE OF ACCOMMODATING ALL LOADS ACCORDING TO SECTION R301 AND OF TRANSMITTING THE RESULTING LOADS TO THE SUPPORTING STRUCTURAL ELEMENTS. R502.2 DESIGN AND CONSTRUCTION WOOD FLOOR FRAMING R502 FLOORS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF THIS CHAPTER. FIGURE R502.2 AND SECTIONS R317 AND R318 OR IN ACCORDANCE WITH AF&PA/ NDS. R502.2.1 FRAMING AT BRACED WALL LINES A LOAD PATH FOR LATERAL FORCES SHALL BE PROVIDED BETWEEN FLOOR FRAMING AND BRACED WALL PANELS LOCATED ABOVE OR BELOW A FLOOR AS SPECIFIED IN SECTION R602.10.8 R502.3 ALLOWABLE JOIST SPANS SPANS FOR FLOOR JOISTS SHALL BE IN ACCORDANCE WITH TABLES R502.3.1(1) AND R502.3.1(2). R502.4 JOISTS UNDER BEARING PARTITIONS JOISTS UNDER PARALLEL BEARING PARTITIONS SHALL BE OF ADEQUATE SIZE TO SUPPORT THE LOAD. DOUBLE JOISTS. SIZED TO ADEQUATELY SUPPORT THE LOAD. THAT AREA SEPARATED TO PERMIT THE INSTALLATION OF PIPING OR VENTS SHALL BE FULL DEPTH SOLID BLOCKED WITH LUMBER NOT LESS THAN 2 INCHES IN NOMINAL THICKNESS SPACED NOT MORE THAN 4 FEET ON CENTER. BEARING PARTITIONS PERPENDICULAR TO JOISTS SHALL NOT BE OFFSET FROM THE SUPPORTING GIRDERS, WALLS, OR PARTITIONS MORE THAN THE JOIST DEPTH UNLESS SUCH JOISTS ARE OF SUFFICIENT SIZE TO CARRY THE ADDITIONAL LOAD. CONCRETE AND MASONRY FOUNDATION WALLS SHALL BE SELECTED AND CONSTRUCTED IN ACCORDANCE WITH PROVISIONS OF SECTION R404 OR IN ACCORDANCE WITH ACI 318. ACI 332. NCMA TR68-A OR ACI 530/ASCE 5/TMS 402 OR OTHER APPROVED STRUCTURAL STANDARDS. WHEN ACI 318. ACI 332 OR ACI 530/ASCE 5/TMS 402 OR THE PROVISION OF SECTION R404 IF THE IRC CODE ARE USED TO DESIGN CONCRETE OR MASONRY FOUNDATION WALLS. PROJECT DRAWINGS. TYPICAL DETAILS AND SPECIFICATIONS ARE NOT REQUIRED TO BEAR THE SEAL OF AN ARCHITECT OR ENGINEER. UNLESS OTHERWISE REQUIRED BY THE STATE LAW OF THE JURISDICTION HAVING AUTHORITY. FOUNDATION WALLS THAT MEET ALL OF THE FIVE PROVISIONS IN SECTION R404.1 SHALL BE CONSIDERED LATERALLY SUPPORTED . 1. CONCRETE, CONCRETE MASONRY AND CLAY MASONRY FOUNDATION WALLS SHALL COMPLY WITH SECTION R404.1.1. 2. CONCRETE, CONCRETE MASONRY AND CLAY MASONRY FOUNDATION WALLS IN SEISMIC DESIGN CATEGORIES D0, D1, AND D2 SHALL COMPLY WITH SECTION R404.1.4.1. 3. A DESIGN IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE SHALL BE PROVIDED FOR CONCRETE OR MASONRY FOUNDATION WALLS WHEN SUCH WALLS ARE SUBJECT TO HYDROSTATIC PRESSURE FROM GROUND WATER, OR SUPPORTING MORE THAN 48 INCHES OF UNBALANCED BACKFILL THAT DO NOT HAVE PERMANENT LATERAL SUPPORT AT THE TOP AND BOTTOM AS PER SECTION R404.1.3 4. PLAN CONCRETE AND PLAN MASONRY FOUNDATION WALLS LOCATED IN SEISMIC DESIGN CATEGORIES D0, D1, AND D2 SHALL BE IN ACCORDANCE WITH SECTION R404.1.4. 5. FOUNDATION WALL THICKNESS BASED ON WALLS SUPPORTED SHALL BE IN ACCORDANCE WITH SECTION R404.1.5. 6. FOUNDATION WALLS SHALL EXTEND ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION A MINIMUM OF 4 INCHES WHERE MASONRY VENEER IS USED AND A MINIMUM OF 6 INCHES ELSEWHERE AS PER SECTION R404.1.6 THE UNDER-FLOOR SPACE BETWEEN THE BOTTOM OF THE FLOOR JOISTS AND THE EARTH UNDER ANY BUILDING (EXCEPT SPACE OCCUPIED BY A BASEMENT) SHALL HAVE VENTILATION OPENINGS THROUGH FOUNDATION WALLS OR EXTERIOR WALLS. THE MINIMUM NET AREA OF VENTILATION OPENINGS SHALL NOT BE LESS THAN I SQUARE FOOT FOR EACH 150 SQUARE FEET OF UNDER FLOOR SPACE AREA. ONE SUCH VENTILATION OPENING SHALL BE WITHIN 3 FEET OF EACH CORNER OF THE BUILDING. R502.8 CUTTING, DRILLING AND NOTCHING STRUCTURAL FLOOR MEMBERS SHALL NOT BE CUT, BORED, OR NOTCHED IN EXCESS OF THE LIMITATIONS SPECIFIED IN THIS SECTION. SEE FIGURE R502.8. I.R.C. WALL CONSTRUCTION - CHAPTER 6 WOOD WALL FRAMING R602 R602.10 WALL BRACING BUILDINGS SHALL BE BRACED IN ACCORDANCE WITH THIS SECTION OR, WHEN APPLICABLE, SECTION R602.12. WHERE A BUILDING DOES NOT COMPLY WITH ONE OR MORE OF THE BRACING REQUIREMENTS IN THIS SECTION, THOSE PORTIONS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH SECTION R301.1. BRACED WALL PANEL CONSTRUCTION METHODS SHALL BE IN ACCORDANCE TO R602.10.2. ALTERNATE BRACED WALL PANELS SHALL BE IN ACCORDANCE TO R602.10.2. I.R.C. WALL COVERINGS - CHAPTER 7 R703.2 WATER-RESISTIVE BARRIER EXTERIOR COVERING R703 ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM HOLES AND BREAKS, COMPLYING WITH ASTM D 226 FOR TYPE I FELT OR OTHER APPROVED WATER-RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL EXTERIOR WALLS. SUCH FELT OR MATERIAL SHALL BE APPLIED HORIZONTALLY, WITH THE UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 INCHES. THE FELT OR APPROVED MATERIAL SHALL BE CONTINUOUS TO THE TOP OF THE WALLS AND TERMINATE AT PENETRATIONS AND THE BUILDING APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL ENVELOPE AS DESCRIBED IN SECTION R703.1. R703.7. EXTERIOR PLASTER INSTALLATION OF THESE MATERIALS SHALL BE IN COMPLIANCE WITH ASTM C926 AND ASTM C 1063 AND THE PROVISIONS OF THIS CODE. R703.7.1 LATH ALL LATH AND LATH ATTACHMENTS SHALL BE OF CORROSION - RESISTANT MATERIALS. EXPANDED METAL OR WOVEN WIRE LATH SHALL BE ATTACHED WITH 1 1/2 -INCH-LONG, 11 GAUGE NAILS, HAVING A 7/16-INCH HEAD, OR 7/8-INCH-LONG, 16-GAUGE STAPLES, SPACED NOT MORE THAN 6 INCHES, OR AS OTHERWISE APPROVED. R703.7.2 PLASTER PLASTERING WITH PORTLAND CEMENT PLASTER SHALL BE NOT LESS THAN THREE COATS WHEN APPLIED OVER METAL LATH OR WIRE LATH AND SHALL BE NOT LESS THAN TWO COATS WHEN APPLIED OVER MASONRY, CONCRETE. PRESSURE-PRESERVATIVE TREATED WOOD OR DECAY RESISTANT WOOD AS SPECIFIED IN SECTION R317.1 OR GYPSUM BACKING. IF THE PLASTER SURFACE IS COMPLETELY CONCEALED. PLASTER APPLICATION NEED BE ONLY TWO COATS, PROVIDED THE TOTAL THICKNESS IS SET FOURTH IN TABLE R702.1(1). ON WOOD-FRAME CONSTRUCTION WITH AN ON-GRADE FLOOR SLAB SYSTEM, EXTERIOR PLASTER SHALL BE APPLIED TO COVER, BUT NOT EXTEND BELOW, LATH, PAPER AND SCREED . THE PROPORTION OF AGGREGATE TO CEMENTITIOUS MATERIALS SHALL BE SET FOURTH IN TABLE R702.1(3). R703.7.2.1 WEEP SCREEDS A MINIMUM 0.019-INCH (No.26 GALVANIZED SHEET GAUGE). CORROSION-RESISTANT WEEP SCREED OR PLASTIC WEEP SCREED, WITH A MINIMUM VERTICAL ATTACHMENT FLANGE OF 3 1/2 INCHES SHALL BE PROVIDED AT OR BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS IN ACCORDANCE WITH ASTM C 926. THE WEEP SCREED SHALL BE PLACED A MINIMUM OF 4 INCHES ABOVE THE EARTH OR 2 INCHES ABOVE THE PAVED AREAS AND SHALL BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. THE WEATHER-RESISTANT BARRIER SHALL LAP THE ATTACHMENT FLANGE. THE EXTERIOR LATH SHALL COVER THE TERMINATE ON THE ATTACHMENT FLANGE OF THE WEEP SCREED. R703.7.3 WATER-RESISTIVE BARRIERS WATER-RESISTIVE BARRIERS SHALL BE INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD-BASED SHEATHING SHALL INCLUDE A WATER-RESISTIVE VAPOR- PERMEABLE BARRIER WITH THE PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. R703.8.3 LINTELS-STONE VENEER R703.8.4 ANCHORAGE-STONE VENEER MASONRY VENEER SHALL BE ANCHORED TO THE SUPPORTING WALL WITH CORROSION -RESISTANT METAL TIES WHERE VENEER IS ANCHORED TO WOOD BACKINGS BY CORRUGATED SHEET METAL TIES, THE DISTANCE SEPARATING THE VENEER FROM THE SHEATHING MATERIAL SHALL BE A MAXIMUM OF A NOMINAL I INCH. WHERE THE VENEER IS ANCHORED TO WOOD BACKINGS USING METAL STRAND WIRE TIES, THE DISTANCE SEPARATING THE VENEER FROM THE SHEATHING MATERIAL SHALL BE A MAXIMUM OF 4 1/2 INCHES EACH TIE SHALL BE SPACED NOT MORE THAN 24" ON CENTER HORIZONTALLY AND VERTICALLY AND SHALL SUPPORT NOT MORE THAN 2.67 SQUARE FEET OF WALL AREA AS PER SECTION R703.7.4.1 I.R.C. ROOF-CLNG CONSTRUCTION CHAPTER 8 GENERAL R801 R801.2 REQUIREMENTS ROOF AND CEILING CONSTRUCTION SHALL BE CAPABLE OF ACCOMMODATING ALL LOADS IMPOSED ACCORDING TO SECTION R301 AND OF TRANSMITTING THE RESULTING LOADS TO THE SUPPORTING STRUCTURAL ELEMENTS. WOOD ROOF FRAMING R802 R802.3 FRAMING DETAILS RAFTERS SHALL BE FRAMED TO RIDGE BOARD OR TO EACH OTHER WITH A GUSSET PLATE AS A TIE . RIDGE BOARD SHALL BE AT LEAST I-INCH NOMINAL THICKNESS AND NOT LESS IN DEPTH THAN THE CUT END OF THE RAFTER. AT ALL VALLEYS AND HIPS THERE SHALL BE A VALLEY OR HIP RAFTER NOT LESS THAN 2-INCH NOMINAL THICKNESS AND NOT LESS IN DEPTH THAN THE CUT END OF THE RAFTER. HIP AND VALLEY RAFTERS SHALL BE SUPPORTED AT THE RIDGE BY A BRACE TO A BEARING PARTITION OR BE DESIGNED TO CARRY AND DISTRIBUTE THE SPECIFIC LOAD AT THAT POINT. WHERE ROOF PITCH IS LESS THAN 3 UNITS VERTICAL IN 12 UNITS HORIZONTAL. STRUCTURAL MEMBERS THAT SUPPORT RAFTERS AND CEILING JOISTS, SUCH AS RIDGE BEAMS, HIP AND VALLEYS. SHALL BE DESIGNED AS BEAMS. CEILING JOISTS AND RAFTER CONNECTORS AND LAPS SHALL BE IN ACCORDANCE TO SECTION R802.3.1 AND R802.3.2. R802.4 ALLOWABLE CEILING JOIST SPANS SPANS FOR CEILING JOISTS SHALL BE IN ACCORDANCE WITH TABLES R802.4(1) AND R802.4 (2). FOR OTHER GRADES AND SPECIES AND FOR OTHER LOADING CONDITIONS. REFER TO AF&PA SPAN TABLES FOR JOISTS AND RAFTERS . R802.5 ALLOWABLE RAFTER SPANS SPANS FOR RAFTERS SHALL BE IN ACCORDANCE WITH TABLES R802.5(1) AND R802.5.1(8). FOR OTHER GRADES AND SPECIES AND FOR OTHER LOADING CONDITIONS. REFER TO AF&PA SPAN TABLES FOR JOISTS AND RAFTERS. THE SPAN OF EACH RAFTER SHALL BE MEASURED ALONG THE HORIZONTAL PROJECTION OF THE RAFTER. R802.5.1 PURLINS INSTALLATION OF PURLINS TO REDUCE THE SPAN OF RAFTERS IS PERMITTED AS SHOWN IN FIGURE R802.5.1. PURLINS SHALL BE SIZED NO LESS THAN THE REQUIRED SIZE OF THE RAFTERS THAT THEY SUPPORT. PURLINS SHALL BE CONTINUOUS AND SHALL BE SUPPORTED BY 2-INCH BY 4-INCH BRACES INSTALLED TO BEARING WALLS AT A SLOPE NO MORE THAN 45 DEGREES FROM THE HORIZONTAL. THE BRACES SHALL BE SPACED NOT MORE THAN 4 FEET ON CENTREX AND THE UNBRACED LENGTH OF BRACES SHALL NOT EXCEED 8 FEET. ROOF VENTILATION R806 R806.1 VENTILATION REQUIRED ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILING ARE APPLIED DIRECTLY TO THE UNDERSIDE OF THE ROOF RAFTER SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. VENTILATING OPENINGS SHALL BE PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WITH 1/16 INCH MINIMUM TO 1/4 INCH MAXIMUM OPENINGS. R806.2 MINIMUM VENT AREA THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OF THE AREA OF THE SPACE VENTILATED, EXCEPT THAT REDUCTION OF THE TOTAL AREA TO 1/300 IS PERMITTED PROVIDED THAT AT LEAST 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE MEASURED VERTICALLY. R806.3 VENT AND INSULATION CLEARANCE WHERE EAVE OR CORNICE VENTS ARE INSTALLED, INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. A MINIMUM OF A I- INCH SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING AND AT THE LOCATION OF THE VENT. ATTIC ACCESS R807 BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF CONSTRUCTION SHALL HAVE AN ATTIC ACCESS OPENING TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET AND HAVE A VERTICAL HEIGHT OF 30 INCHES OR MORE. THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22 INCHES BY 30 INCHES AND SHALL BE LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION. A 30 INCH MINIMUM UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT SOME POINT ABOVE THE ACCESS OPENING. SEE SECTION M1305.1.3 FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS LOCATED IN ATTICS. R807.1 ATTIC ACCESS MASONRY VENEER SHALL NOT SUPPORT ANY VERTICAL LOAD OTHER THAN THE DEAD LOAD OF THE VENEER ABOVE. VENEER ABOVE OPENINGS SHALL BE SUPPORTED ON LINTELS OF NONCOMBUSTIBLE MATERIALS AND THE ALLOWABLE SPAN SHALL NOT EXCEED THE VALUE SET FOURTH IN TABLE R703.7.3.1. THE LINTELS SHALL HAVE A LENGTH OF BEARING NOT LESS THAN 4 INCHES. R502.3.3 FLOOR CANTILEVERS FLOOR CANTILEVER SPANS SHALL NOT EXCEED THE NOMINAL DEPTH OF THE WOOD FLOOR JOIST. FLOOR CANTILEVERS CONSTRUCTED IN ACCORDANCE WITH TABLE R502.3.3(1) SHALL BE PERMITTED WHEN SUPPORTING A LIGHT-FRAME BEARING WALL OR ROOF ONLY. R602.10.1 BRACED WALL LINES FOR THE PURPOSE OF DETERMINING THE AMOUNT AND LOCATION OF BRACING REQUIRED IN EACH STORY LEVEL OF A BUILDING, BRACED WALL LINES SHALL BE DESIGNATED AS STRAIGHT LINES IN THE BUILDING PLACED IN ACCORDANCE WITH THIS SECTION. THE PROVISIONS OF THIS SECTION SHALL CONTROL THE CONSTRUCTION OF EXTERIOR STRUCTURAL INSULATED PANEL (SIP) WALLS AND INTERIOR LOAD-BEARING SIP WALLS FOR BUILDINGS NOT GREATER THAN 60 FEET IN LENGTH PERPENDICULAR TO THE JOIST OR TRUSS SPAN, NOT GREATER THAN 40 FEET IN WIDTH PARALLEL TO THE JOIST OR TRUSS SPAN AND NOT GREATER THAN TWO STORIES IN HEIGHT WITH EACH WALL NOT GREATER THAN 10 FEET HIGH. STRUCTURAL INSULATED PANEL WALL CONSTRUCTION R610 R610.2 APPLICABILITY LIMITS SIPS SHALL COMPLY WITH FIGURE R610.4 AND SHALL HAVE MINIMUM PANEL THICKNESS IN ACCORDANCE WITH TABLES R610.5(1) AND R610.5(2) FOR ABOVE-GRADE WALLS. ALL SIPS SHALL BE IDENTIFIED BY GRADE MARK OR CERTIFICATE OF INSPECTION ISSUED BY AN APPROVED AGENCY. R610.4 SIP WALL PANELS GSPublisherVersion 1148.0.46.46 DE T A I L E D DR A F T I N G & DE S I G N Sheet #: DRAWN BY: DCB 435-592-4287 A1.0 Revisions: Dr a w i n g Da t e : 9/25 /20 2 0 Sc a l e : As No t e d Sh e e t Co n t e n t s : MA I N FL O O R PL A N DE T A I L E D DR A F T I N G & DE S I G N EX P R E S S L Y RE S E R V E S IT S CO M M O N LA W CO P Y R I G H T AN D OT H E R PR O P E R T Y RI G H T S IN H E R E N T IN TH E S E PL A N S . AL L DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S AR E IN S T R U M E N T S OF SE R V I C E AN D AR E TH E PR O P E R T Y OF DE T A I L E D DR A F T I N G & DE S I G N AL L IN F O R M A T I O N CO N T A I N E D IN TH E S E S DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S IS PR O J E C T SP E C I F I C AN D SH A L L NO T BE RE P R O D U C E D , DI S C L O S E D , CH A N G E D , OR CO P I E D WI T H O U T FI R S T OB T A I N I N G TH E EX P R E S S WR I T T E N PE R M I S S I O N AN D CO N S E N T OF DE T A I L E D DR A F T I N G & DE S I G N PR E L I M I N A R Y - NO T FO R CO N S T R U C T I O N 55 N 60 0 E, ST GE O R G E , UT 84 7 7 0 WW W .DE T A I L E D D R A F T I N G .CO M NI C K & JE N N A EM E R Y LO T 38 IN TH E PR E S E R V E RE X B U R G , ID A H O NE W 2 BA Y GA R A G E FO R 12-0X14-0 - OVERHEAD9-0X9-0 - OVERHEAD 2'-0" 5'-0" 2'-0" 5'-0" 2'-0" 5'-0" 2'-0" 5'-0" 3'-0" 8'-0" 8-0X8-0 - OVERHEAD 5'-0" 3'-0" 5'-0" 3'-0" 5'-0" 3'-0" 5'-0" 3'-0" 2'-8" 5'-0" 2'-8" 5'-0" 6'-8" 3'-0" SHOP13'-6" x 22'-6"13'-6" x 22'-6"10'-0 Clg. Hgt. 50 ' - 2 " 8" 6' - 0 " 12 ' - 2 " 12 ' - 2 " 12 ' - 2 " 7' - 0 " 14'-0"18'-0" 32'-0" 3'-0"8'-0"3'-0"7'-8"2'-8"7'-8" 49 ' - 2 " 8" 25 ' - 0 " 23 ' - 6 " 6' - 0 " 12 ' - 2 " 4' - 1 0 " 2' - 0 " 5' - 4 " 12 ' - 2 " 6' - 0 " 14'-0"18'-0" 32'-0" 2'-6"9'-0"2'-6"2'-0"1'-0"12'-0"1'-0"2'-0" 2 A3.0 2 A3.0 1 A3.0 1 A3.0 STRUCTURAL ENGINEER SHOULD BE CONSULTED PRIOR TO CONSTRUCTION . GENERAL STRUCTURAL NOTES 1. OWNER IS RESPONSIBLE TO VERIFY THIS HOUSE IS BUILT IN COMPLIANCE WITH ALL LOCAL ORDINANCES. DESIGNER IS NOT RESPONSIBLE FOR SITE CONDITIONS AND/OR THE USE OF THE DRAWINGS DURING CONSTRUCTION. 2. BUILDER MUST VERIFY ALL STRUCTURAL ELEMENTS FOR DESIGN AND SIZE WITH A LOCAL ENGINEER AND BUILDING OFFICIALS. 3. EXACT SPECIFICATION FOR ALL CONCRETE FOUNDATIONS (i.e. SIZE & REINFORCEMENT MUST BE DETERMINED BY LOCAL SOIL CONDITIONS AND ALL CODES THAT APPLY LOCALLY. VERIFY STRUCTURAL DESIGN WITH LOCAL ENGINEER. 4. STRUCTURAL LIABILITY: THE STRUCTURAL FRAMING SYSTEMS (STRUCTURAL ELEMENTS SUCH AS BUT NOT LIMITED TO FOOTINGS , FOUNDATION WALLS, REINFORCED CONCRETE, FRAMING WALLS, STRUCTURALLY INSULATED PANEL WALLS & ROOF BEAMS, CONNECTIONS, HEADERS, JOISTS, RAFTERS AND TRUSSES), FOR THIS HOUSE IS FOR REFERENCE PURPOSE ONLY. A LOCAL GARAGE 1,582 Sq Ft SQUARE FOOTAGE SCALE: 1/4" = 1'-0"1 MAIN FLOOR PLAN GSPublisherVersion 1148.0.46.46 DE T A I L E D DR A F T I N G & DE S I G N Sheet #: DRAWN BY: DCB 435-592-4287 A1.1 Revisions: Dr a w i n g Da t e : 9/25 /20 2 0 Sc a l e : As No t e d Sh e e t Co n t e n t s : RO O F & SI T E PL A N DE T A I L E D DR A F T I N G & DE S I G N EX P R E S S L Y RE S E R V E S IT S CO M M O N LA W CO P Y R I G H T AN D OT H E R PR O P E R T Y RI G H T S IN H E R E N T IN TH E S E PL A N S . AL L DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S AR E IN S T R U M E N T S OF SE R V I C E AN D AR E TH E PR O P E R T Y OF DE T A I L E D DR A F T I N G & DE S I G N AL L IN F O R M A T I O N CO N T A I N E D IN TH E S E S DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S IS PR O J E C T SP E C I F I C AN D SH A L L NO T BE RE P R O D U C E D , DI S C L O S E D , CH A N G E D , OR CO P I E D WI T H O U T FI R S T OB T A I N I N G TH E EX P R E S S WR I T T E N PE R M I S S I O N AN D CO N S E N T OF DE T A I L E D DR A F T I N G & DE S I G N PR E L I M I N A R Y - NO T FO R CO N S T R U C T I O N 55 N 60 0 E, ST GE O R G E , UT 84 7 7 0 WW W .DE T A I L E D D R A F T I N G .CO M NI C K & JE N N A EM E R Y LO T 38 IN TH E PR E S E R V E RE X B U R G , ID A H O NE W 2 BA Y GA R A G E FO R 3:12 12:12 12:12 32 ' - 6 3/ 4 " 48 ' - 6 " 33'-0"25'-0" 16 1 '-0" 30 ' SETBACK LINE 2 5 ' S E T B A C K L I N E 10 ' SETBACK LINE 10 ' SE T B A C K LI N E 296 '-5 " 253 '-0 " 1 2 1 ' - 6 " R=20'-0" L=31'-0"HENRY 'S FORK WAY Y O S E M I T E C I R . WA T E R WE L L AP P R O X . LO C A T I O N EXI S T I N G HO M E SCALE: 1" = 10'1 ROOF & SITE PLAN GSPublisherVersion 1148.0.46.46 DE T A I L E D DR A F T I N G & DE S I G N Sheet #: DRAWN BY: DCB 435-592-4287 A2.0 Revisions: Dr a w i n g Da t e : 9/25 /20 2 0 Sc a l e : As No t e d Sh e e t Co n t e n t s : EX T E R I O R EL E V A T I O N S DE T A I L E D DR A F T I N G & DE S I G N EX P R E S S L Y RE S E R V E S IT S CO M M O N LA W CO P Y R I G H T AN D OT H E R PR O P E R T Y RI G H T S IN H E R E N T IN TH E S E PL A N S . AL L DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S AR E IN S T R U M E N T S OF SE R V I C E AN D AR E TH E PR O P E R T Y OF DE T A I L E D DR A F T I N G & DE S I G N AL L IN F O R M A T I O N CO N T A I N E D IN TH E S E S DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S IS PR O J E C T SP E C I F I C AN D SH A L L NO T BE RE P R O D U C E D , DI S C L O S E D , CH A N G E D , OR CO P I E D WI T H O U T FI R S T OB T A I N I N G TH E EX P R E S S WR I T T E N PE R M I S S I O N AN D CO N S E N T OF DE T A I L E D DR A F T I N G & DE S I G N PR E L I M I N A R Y - NO T FO R CO N S T R U C T I O N 55 N 60 0 E, ST GE O R G E , UT 84 7 7 0 WW W .DE T A I L E D D R A F T I N G .CO M NI C K & JE N N A EM E R Y LO T 38 IN TH E PR E S E R V E RE X B U R G , ID A H O NE W 2 BA Y GA R A G E FO R SCALE: 1/4" = 1'-0"1 FRONT ELEVATION SCALE: 1/4" = 1'-0"2 RIGHT ELEVATION SCALE: 1/4" = 1'-0"3 LEFT ELEVATION SCALE: 1/4" = 1'-0"4 REAR ELEVATION GSPublisherVersion 1148.0.46.46 DE T A I L E D DR A F T I N G & DE S I G N Sheet #: DRAWN BY: DCB 435-592-4287 A3.0 Revisions: Dr a w i n g Da t e : 9/25 /20 2 0 Sc a l e : As No t e d Sh e e t Co n t e n t s : BU I L D I N G SE C T I O N S DE T A I L E D DR A F T I N G & DE S I G N EX P R E S S L Y RE S E R V E S IT S CO M M O N LA W CO P Y R I G H T AN D OT H E R PR O P E R T Y RI G H T S IN H E R E N T IN TH E S E PL A N S . AL L DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S AR E IN S T R U M E N T S OF SE R V I C E AN D AR E TH E PR O P E R T Y OF DE T A I L E D DR A F T I N G & DE S I G N AL L IN F O R M A T I O N CO N T A I N E D IN TH E S E S DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S IS PR O J E C T SP E C I F I C AN D SH A L L NO T BE RE P R O D U C E D , DI S C L O S E D , CH A N G E D , OR CO P I E D WI T H O U T FI R S T OB T A I N I N G TH E EX P R E S S WR I T T E N PE R M I S S I O N AN D CO N S E N T OF DE T A I L E D DR A F T I N G & DE S I G N PR E L I M I N A R Y - NO T FO R CO N S T R U C T I O N 55 N 60 0 E, ST GE O R G E , UT 84 7 7 0 WW W .DE T A I L E D D R A F T I N G .CO M NI C K & JE N N A EM E R Y LO T 38 IN TH E PR E S E R V E RE X B U R G , ID A H O NE W 2 BA Y GA R A G E FO R FLOOR BEARING RIDGE FLOOR BEARING RIDGE 16 ' - 6 " VA R I E S 16 ' - 6 " VA R I E S RV GARAGE FLOOR BEARING BEARING RIDGE FLOOR BEARING RIDGE 10 ' - 0 " 6' - 6 " 9' - 1 0 " 16 ' - 6 " 9' - 1 0 " RV GARAGE BOAT GARAGE 1" AIR SPACE MIN. 2X FACIA ALUMINUM SOFFIT CDX PLYWOOD SHEATHING 2X FRAMED WALL STUCCO OR SIDING EXTERIOR FINISH DRYWALLDRYWALL PRE-ENGINEERED ROOF TRUSS ATTIC INSULATION CDX PLYWOOD ROOF SHEATING FIBERGALLS COMP. SHINGLES OR METAL ROOFING 2x BLOCKING INSULATION BAFFLE FOOTING BELOW FROST DEPTH GRADE - SLOPE 5% TO 10'-0" AWAY FROM BLDG. SLAB-ON-GRADE P.T. PLATE W/ ANCHOR BOLT AS REQ'D J-METAL WEEP SCREED WALL INSULATION SCALE: 1/4" = 1'-0"2 BUILDING SECTION #2 SCALE: 1/4" = 1'-0"1 BUILDING SECTION #1 SCALE: 1/2" = 1'-0"3 TYPICAL WALL SECTION GSPublisherVersion 1148.0.46.46 DE T A I L E D DR A F T I N G & DE S I G N Sheet #: DRAWN BY: DCB 435-592-4287 A4.0 Revisions: Dr a w i n g Da t e : 9/25 /20 2 0 Sc a l e : As No t e d Sh e e t Co n t e n t s : MA I N FL O O R EL E C T R I C A L DE T A I L E D DR A F T I N G & DE S I G N EX P R E S S L Y RE S E R V E S IT S CO M M O N LA W CO P Y R I G H T AN D OT H E R PR O P E R T Y RI G H T S IN H E R E N T IN TH E S E PL A N S . AL L DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S AR E IN S T R U M E N T S OF SE R V I C E AN D AR E TH E PR O P E R T Y OF DE T A I L E D DR A F T I N G & DE S I G N AL L IN F O R M A T I O N CO N T A I N E D IN TH E S E S DR A W I N G S , EL E C T R O N I C FI L E S , FI E L D NO T E S AN D AS S O C I A T E D DO C U M E N T S IS PR O J E C T SP E C I F I C AN D SH A L L NO T BE RE P R O D U C E D , DI S C L O S E D , CH A N G E D , OR CO P I E D WI T H O U T FI R S T OB T A I N I N G TH E EX P R E S S WR I T T E N PE R M I S S I O N AN D CO N S E N T OF DE T A I L E D DR A F T I N G & DE S I G N PR E L I M I N A R Y - NO T FO R CO N S T R U C T I O N 55 N 60 0 E, ST GE O R G E , UT 84 7 7 0 WW W .DE T A I L E D D R A F T I N G .CO M NI C K & JE N N A EM E R Y LO T 38 IN TH E PR E S E R V E RE X B U R G , ID A H O NE W 2 BA Y GA R A G E FO R S S GF I SS S GFI GF I GF I GFI GF I GF I RV GF I 2. A. Refrigerator F. Kitchen Hood K.Dryer B. Ovens G. Cooktop C. Garbage Disposal H. Furnace D. Dishwasher I. Spa Equipment E. Microwave J. Washing Machine 1. ELECTRICAL 3. 4. 5. 6. 7. 8. 9. 10. ELECTRICAL INFORMATION PROVIDED ON THESE PLANS ARE FOR DESIGN PURPOSES ONLY. FOR POWER AND CABLING DISTRIBUTION, CIRCUITING AND CIRCUIT LOADS AND ALL RELATED INFORMATION CONCERNING ELECTRICAL WORK REFER TO ELECTRICAL SUB-CONTRACTORS. ELECTRICAL WORK TO CONFORM TO ALL LOCAL AND STATE LAWS AND TO BE PERFORMED BY A LICENSED ELECTRICIAN . ALL LIGHTING CIRCUITS SHALL BE CIRCUITS DEDICATED TO LIGHTING ONLY. SMOKE DETECTORS SHALL BE CONNECTED TO A LIGHTING CIRCUIT. TO BE 110V WITH BATTERY BACKUP AND ARE AUDIBLE IN ALL SLEEPING AREAS. AT ALL BATHROOMS ONE 20 AMP BRANCH CIRCUIT SHALL SUPPLY ALL BATHROOM WALL OR COUNTER -TOP OUTLETS ONLY. PROVIDE TWO 20 AMP BRANCH CIRCUITS TO THE KITCHEN. THESE CIRCUITS SHALL BE LIMITED TO SUPPLYING WALL AND COUNTER SPACE OUTLETS WITHIN THE KITCHEN. THESE CIRCUITS SHALL NOT BE USED FOR LARGE APPLIANCES. ALL BEDROOM ELECTRICAL RECEPTACLES SHALL BE OF THE ARC-FAULT CIRCUIT INTERRUPTER TYPE, TYP. THE FOLLOWING APPLIANCES SHALL BE ON A DEDICATED CIRCUIT : A SEPARATE DEDICATED 20 AMP BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY LAUNDRY RECEPTACLE OUTLET . LIGHT FIXTURES IN TUB OR SHOWER ENCLOSURES SHALL HAVE "SUITABLE FOR DAMP LOCATIONS" LABEL. IF IN COMBINATION WITH EXHAUST FAN FIXTURE, EXHAUST FAN MUST PROVIDE MINIMUM OF 5 AIR CHANGES PER HOUR. ELECTRICAL GROUNDING SYSTEM SHALL BE PER ALL APPLICABLE CODES. CONTRACTOR AND/OR ELECTRICAL SUB-CONTRACTOR SHALL SELECT GROUNDING METHOD MOST COMPATIBLE WITH FOUNDATION SYSTEM . FLOOD LIGHT W.P. S.D. DUPLEX OUTLET EXHAUST FAN INCANDESCENT LIGHT EMERGENCY LIGHT GROUND FAULT INTERRUPT HANGING LIGHT UNDER CABINET LIGHT 4 BULB 4' FLOURESCENT LIGHT FLOOR DUPLEX OUTLET SWITCHED DUPLEX OUTLET SMOKE & C.O. DETECTORC.O. 8' FLOURESCENT LIGHT S WALL MOUNT INCANDESCENT LIGHT PLANTER FLOOD SMOKE DETECTOR PHOTO CELL E PH.C. TELEVISIONTV PHONE DUPLEX OUTLET -GFI DUPLEX OUTLET - S.D. 220 OUTLET SWITCH C CEILING FAN W/LIGHT KIT CEILING FAN COMPUTER OUTLET ELECTRICAL KEY PENDENT INCANDESCENT LIGHT WEATHER PROTECTED HEAT-LIGHT/FAN EYEBALL RECESSED PH. VANITY LIGHT 2 BULB 4' FLOURESCENT LIGHT RECESSED INCANDESCENT SCALE: 1/4" = 1'-0"1 MAIN FLOOR ELECTRICAL GENERAL STRUCTURAL NOTES GENERAL 1. Construction documents are valid for a single use at the project location and shall not be reused, copied, or reproduced without written approval of the registered design professional in responsible charge. 2. General notes and typical details are provided as a supplement to the construction documents and apply where specific notes and details are not available. Specific notes and structural details shall take precedence over general notes and typical details. Structural requirements shown in the framing plans and in structural details shall take precedence over structural notes indicated in architectural sections. 3. Printed dimensions shall take precedence over scales shown on construction documents. The registered design professional in responsible charge does not warrant the accuracy of scaled dimensions. 4. Approval by the inspector does not imply approval by the registered design professional in responsible charge. Structural specifications that are unclear or ambiguous shall be referred to the registered design professional in responsible charge for interpretation or clarification. 5. The registered design professional in responsible charge assumes no liability for the accuracy, completeness, or code compliance of architectural, electrical, mechanical, drainage, or other non-structural specifications. 6. Omissions in and conflicts between the various elements of the construction documents shall be brought to the immediate attention of the registered design professional in responsible charge and shall be resolved by the same before proceeding with any work involved. 7. Requests for substitutions shall be submitted in writing to the registered design professional in responsible charge and shall include the reasons for the request and any cost differentials. Substitutions are not allowed unless approved in writing by the registered design professional in responsible charge. 8. The contractor shall become familiar with all portions of the construction documents and shall ensure that all subcontractors are familiar with those portions pertaining to their area of work. The contractor shall verify all site conditions, dimensions, elevations, coordinate all doors, windows, non-bearing interior and exterior walls, elevations, slopes, stairs, curbs, drains, recesses, depressions, railings, waterproofing, finishes, chamfer, kerfs, and so forth, and immediately notify the registered design professional in responsible charge regarding actual conditions which are not in agreement with the construction documents. 9. The contractor is responsible for the method, means, and sequence of all structural erection except when specifically noted otherwise in the construction documents. The contractor shall provide temporary shoring and bracing, providing adequate vertical and lateral support during erection. Shoring and bracing shall remain in place until all permanent members are placed and all final connections are completed. 10.The contractor is responsible for standard connections, unless noted otherwise. The contractor shall obtain additional assistance from the registered design professional in responsible charge for non-standard connections. SOIL AND FOUNDATIONS 1. Geotechnical investigations shall conform to 2018 IBC 1803. Excavation, grading and fill shall conform to 2018 IBC 1804. Footings and foundations shall be constructed in accordance with 2018 IBC 1807 through 1810. 2. Where required, the owner shall submit a geotechnical investigation report to the building official in accordance with 2018 IBC 1803. The contractor shall inform the registered design professional in responsible charge if the soil conditions are not consistent with the investigation report and the foundation design data. 3. Excavations for any purpose shall not remove lateral support from any footing or foundation without first underpinning or protecting the footing or foundation against settlement or lateral translation (2018 IBC 1804.1). 4. Excavation outside the foundation shall be backfilled with soil that is free of organic material, construction debris, cobbles and boulders or with a controlled low-strength material (CLSM). The backfill shall be placed in lifts and compacted, in a manner that does not damage the foundation or the waterproofing or dampproofing material (2018 IBC 1804.3). 5. The ground immediately adjacent to the foundation shall have a 5-percent slope away from the building for a minimum distance of 10 feet measured perpendicular to the face of the foundation wall. If physical obstructions or lot lines prohibit 10 feet of horizontal distance, a 5-percent slope shall be provided to an approved alternative method of diverting water away from the foundation. Impervious surfaces within 10 feet of the building foundation shall have a minimum 2-percent slope (2018 IBC 1804.4). 6. Footings and foundations shall be built on undisturbed soil, compacted fill material or CLSM. Compacted fill material and CLSM shall conform to 2018 IBC 1804.6 and 2018 IBC 1804.7, respectively (2018 IBC 1809.2). 7. The top surface of the footings shall be level. The bottom surface of footings is permitted to have a maximum 10-percent slope. Footings shall be stepped where it is necessary to change the elevation of the top surface of the footing or where the surface of the ground has more than a 10-percent slope (2018 IBC 1809.3). 8. The minimum depth of footings below the undisturbed ground surface shall be 12 inches (2018 IBC 1809.4). Foundation walls, piers and other permanent supports shall be extended below the frost line, except where otherwise protected from frost (2018 IBC 1809.5). 9. The placement of footings on or adjacent to 33-percent slopes and steeper shall conform to 2018 IBC 1808.7. 10.Floors of basements shall be placed over base course not less than 4 inches in thickness and a drain shall be installed around the foundation perimeter that consists of gravel or crushed stone containing not more than 10-percent material that passes through a No. 4 sieve (2018 IBC 1805.4.1, 1805.4.2). 11.Backfill shall not be placed against a foundation wall until the wall has sufficient strength and is anchored to the floor above, or is sufficiently braced to prevent damage by the backfill, except bracing is not required for walls supporting less than 4 feet of unbalanced backfill (R404.1.7). CONCRETE 1. Concrete materials, quality control, and construction shall comply with 2018 IBC Chapter 19 and ACI 318-14. 2. Compressive strength (minimum specified at 28 days) 2.1. Footings: 3,000 psi (2018 IBC 1808.8.1) (2,500 psi used in design) 2.2. Interior floor slabs on grade: 4,000 psi 2.3. Exterior floor slabs on grade: 4,000 psi 2.4. Suspended slabs: 4,000 psi 2.5. Walls: 3,000 psi (2018 IBC 1904.1) for R-2, R-3 occupancies and appurtenances 4,000 psi for other occupancies 3. Materials 3.1. Cements (ASTM C 150). Concrete exposed to freezing and thawing or deicing chemicals shall conform to the maximum water-cementitious material ratios and minimum compressive strength requirements of ACI 318-14 table 19.3.1.1 & 19.3.2.1 3.2. Aggregates (ASTM C 33): nominal maximum size of coarse aggregate shall not be larger than 1/5 the narrowest dimension between forms, nor 1/3 the depth of slabs, nor 3/4 the minimum clear spacing between reinforcing bars or wires, tendons, or ducts (ACI 318-14 26.4.2.1). 3.3. Water used in mixing concrete shall be potable, clean and free from injurious amounts of oils, acids, alkalis, salts, organic materials, or other substances deleterious to concrete or reinforcement (ACI 318-14 26.4.1.3.1.b). 3.4. Admixtures shall be subject to prior approval by the registered design professional in responsible charge (ACI 318-14 26.4.1.4.1.b). 3.5. Concrete exposed to freezing and thawing or deicing chemicals shall be air-entrained with air content indicated in ACI 318-14 Table 19.3.3.1. Tolerance on air content as delivered shall be plus/minus 1.5 percent (ACI 318-14 R26.4.2.1(a)(5)). 4. Steel Reinforcement 4.1. Deformed bars: fy = 60 ksi (ASTM A615) 4.2. Welded plain wire: fy = 60 ksi (ASTM A1064) 4.3. Deformed Bar Anchors (DBA) (ASTM A1064) 4.4. Headed Stud Anchors (HSA) (ASTM A108) 4.5. At the time concrete is placed, reinforcement shall be free from ice, mud, oil, or other nonmetallic coatings that decrease bond (ACI 318-14 26.6.1.2). 4.6. Reinforcement shall be accurately placed and adequately supported before concrete is placed, and shall be secured against displacement (ACI 318-14 26.6.2.2). 4.7. Details of reinforcement shall conform to ACI 318-14 Chapter 25. 5. Minimum concrete cover (ACI 318-14 Table 20.6.1.3.1) 5.1. Concrete cast against and exposed to earth: 3 inches 5.2. Concrete exposed to earth or weather: 5.2.1. No. 6 through No. 18 bars: 2 inches 5.2.2. No. 5 bar, W31 wire, and smaller: 1.5 inches 5.3. Concrete not exposed to earth or weather: 5.3.1. Slabs, walls, joists No. 11 bar and smaller: 0.75 inches 5.3.2. Beams, columns primary reinf., ties, stirrups: 1.5 inches 6. Formwork shall conform to ACI 318-14 Sections 26.11 and 26.12 and ACI 347. Forms shall be removed in a manner as not to impair safety and serviceability of the structure. Concrete exposed by form removal shall have sufficient strength not to be damaged by removal operation (ACI 318-14 26.11.2). 7. Conduits, pipes, and sleeves of any material not harmful to concrete and within the limitations of ACI 318-14 20.7 shall be approved by the registered design professional in responsible charge (ACI 318-14 20.7). 8. Construction joints shall be so made and located as not to impair the strength of the structure (ACI 318-14 18.10.9). 9. The thickness of concrete floor slabs on grade shall not be less than 3.5 inches. A 6-mil polyethylene vapor retarder with joints lapped not less than 6 inches (or an equivalent material) shall be placed between the base course or subgrade and the concrete floor slab, except a vapor retarder is not required in detached utility buildings or other unheated facilities (2018 IBC 1907). MASONRY 1. Masonry materials, construction, and quality shall conform to 2018 IBC 2103-2105, TMS 402/602-16 1.1. Compressive strength: f'c = 2,000 psi (TMS 602-16 1.4B.2 TABLE 2) 2. Concrete masonry units (CMU) (ASTM C 90) 2.1. Grade N 2.2. Compressive strength: f'm = 2,000 psi (TMS 602-16 1.4B.2 TABLE 2) 3. Mortar (ASTM C 270) 3.1. Type S Portland cement (TMS 402-16 7.4.4.2.2) 3.2. Compressive strength: f'c = 2,000 psi (TMS 602-16 1.4B.2 TABLE 2) 4. Grout (ASTM C 476) 4.1. Type: fine or coarse (2018 IBC 2103.3) 4.2. Compressive strength (minimum specified at 28 days): f'c = 2,000 psi (ASTM C 1019) 5. Steel reinforcement 5.1. Deformed bars: fy = 60 ksi (ASTM A 615 Gr. 60) 5.2. Deformed Bar Anchors (DBA) (ASTM A1064) 5.3. Headed Stud Anchors (HSA) (ASTM A108) 6. Bed joint thickness shall be 5/8 inch maximum (TMS 602-16 1.4B.2) 7. Grout shall have an 8”-11” slump using a 3/8” maximum aggregate. Grout lifts shall not exceed 5 feet in height unless noted otherwise. Consolidate by mechanical vibration pours that exceed 12 inches in height. 8. The clear distance between parallel bars shall not be less than the nominal diameter of the bars, nor less than 1 inch (TMS 402-16 6.1.3). Joint reinforcement shall have cover not less than 5/8". (TMS 402-16 6.1.4.2) 9. The diameter of bend measured on the inside of reinforcing bars, other than for stirrups and ties, shall not be less than specified in table 6.1.8 (TMS 402-16 6.1.8.2) 10.All masonry below grade shall be solid grouted. 11.Control joint spacing not to exceed 30'-0". See Architectural for locations. MASONRY AND STONE VENEER 1. Masonry veneer materials, construction, and quality shall conform to 2018 IBC 2103-2105 and TMS 402-16 Chap. 6. 2. Lintels 2.1. Veneer shall not support any vertical load other than the dead load of the veneer above. Veneer above openings shall be supported on lintels of noncombustible materials. Lintels shall have 1 inch of bearing for each 1 foot of span, but not less than 4 inches of bearing. 3. Anchorage 3.1. Veneer shall be anchored to the supporting wall framing with hot-dipped galvanized metal ties. (Strand wire or corrugated sheet metal) 3.2. Engage all anchor ties with a No. 9 gage wire in the center of the veneer and embedded in the mortar joint. (R703.8.4.1) 3.3. Each tie shall be spaced not more than 16 inches on center horizontally and vertically and shall support not more than 2 square feet of wall area. Additional metal ties shall be provided around all wall openings greater than 16 inches in either dimension. (R703.8.4.1) WOOD 1. Wood materials, quality, and construction shall conform to 2018 IBC Chapter 23 and Table 2304.10. 2. Structural lumber (2018 IBC 2303.1.1-9, 2018 NDS) 2.1. Bearing walls: Douglas-Fir Larch (DF) Stud (ASTM D 1990, DOC PS 20) 2.2. Posts: Douglas-Fir Larch (DF) Stud (ASTM D 1990, DOC PS 20) 2.3. Beams and headers: Douglas-Fir Larch (DF) No. 2 (ASTM D 1990, DOC PS 20) 2.4. Heavy timber: Douglas-Fir Larch (DF) No. 1 (ASTM D 1990, DOC PS 20) 2.5. Sill plates: Preservative-treated wood, redwood (AWPA U1 M4) 2.6. Naturally durable or preservative-treated wood shall be used where structural lumber is 18 inches or closer to exposed ground; where structural lumber is in contact with exterior masonry or concrete walls below grade; where sleepers, sills, posts, and columns are on a concrete or masonry slab or footing that is in direct contact with earth; and where structural lumber is attached directly to exterior masonry or concrete walls, unless a 0.5 inch air space on top, sides, and end is provided (2018 IBC 2304.12). 3. Structural logs (ASTM D 3957) - ICC - 400 standard for the design and construction of log structures 4. Structural glued-laminated timber (2018 IBC 2303.1.3, 2018 NDS 5.1.1) 4.1. Single span: 24F-1.8E (24F-V4) (ASTM D 3737, ANSI/AITC A190.1) 4.2. Multiple span: 24F-1.8E Balanced layup (24F-V8) (ASTM D 3737, ANSI/AITC A190.1) 4.3. Cantilever span: 24F-1.8E Balanced layup (24F-V8) (ASTM D 3737, ANSI/AITC A190.1) 5. Structural composite lumber and engineered wood (2018 IBC 2303.1.10, 2018 NDS 8.1.1) 5.1. Laminated strand lumber (LSL) 5.1.1. Ex = 1.3E (ASTM D 5456) 5.1.2. Ex = 1.5E (ASTM D 5456) 5.1.3. Ex = 1.55E (ASTM D 5456) 5.1.4. 1.125 inch APA Performance-Rated (or equivalent) rim board - (2018 IBC 2303.1.13, ASTM 7672, ANSI/APA PRR410) 5.2. Laminated veneer lumber (LVL) 5.2.1. Ex = 2.0E (ASTM D 5456) 5.3. Parallel strand lumber (PSL) 5.3.1. Ex = 2.0E (beams) (ASTM D 5456) 5.3.2. Ex = 1.8E (columns) (ASTM D 5456) 5.4. Prefabricated wood I-joist (2018 IBC 2303.1.2, 2018 NDS 7.1.1) (ASTM D 5055) 6. Wood structural panels (2018 IBC 2304.8, 2018 NDS 9.1.3) 6.1. Roof, floor, and wall sheathing: oriented strand board (OSB) (DOC PS 1,2). 6.2. Sheathing shall be manufactured with exterior glue and not less than 4X8 feet, except at boundaries and at changes in framing (2018 IBC 2305.1, AWC SDPWS-2015). 6.3. Wall sheathing 6.3.1. Oriented strand board (OSB) (DOC PS 1,2) 6.3.2. All panel joints in walls shall occur over studs or blocking using a minimum of 8d common nails spaced a maximum of 6 inches at panel edges and 12 inches at intermediate framing (2018 IBC 2306.3). 6.4. Roof and floor sheathing shall be placed perpendicular to supporting framing. Stagger sheathing joints. 7. Fasteners 7.1. Nails (2018 IBC 2303.6, 2018 NDS Table L4) (ASTM F 1667) Pennyweight Common Box Sinker 7.1.1. 8d = 0.131" X 2.5" 0.113" X 2.5" 0.113" X 2.375" 7.1.2. 10d = 0.148" X 3.0" 0.128" X 3.0" 0.120" X 2.875" 7.1.3. 16d = 0.162" X 3.5" 0.135" X 3.5" 0.148" X 3.250" 7.1.4. 20d = 0.192" X 4.0" 0.148" X 4.0" 0.177" X 3.750" 7.1.5. 30d = 0.207" X 4.5" 0.148" X 4.5" 0.192" X 4.250" 7.2. Staples (2018 IBC 2303.6) 7.2.1. 16 gage = 1.5X0.4375 inch crown (ASTM F 1667) 7.3. Bolts (2018 NDS 12.1.3, Table L1) 7.3.1. Connector bolts (A307) 7.3.2. Anchor bolts (A307) with a 3X3X0.229 inch washer (2018 IBC 2308.3.1) and 7" min embedment. 7.3.3. Bolt holes shall be drilled with a bit 1/32 inch to 1/16 inch larger than the nominal bolt diameter. 7.4. Lag Screws (2018 NDS 12.1.4, Table L2) (A307) 7.4.1. Lag screws shall be inserted in a drilled pilot hole that is 60%-75% of the shank diameter by turning with a wrench. Do not drive screws with a hammer. Lag screws shall be provided with an oversized washer . 7.5. Fasteners in preservative-treated and fire-retardant-treated wood shall be of hot dipped zinc-coated galvanized steel, silicon bronze or copper (2018 IBC 2304.10.5). 7.6. Sheathing fasteners shall be driven so the head or crown is flush with the sheathing surface (2018 IBC 2304.10.2). 8. Joist hangers and connectors (2018 IBC 2303.5) 8.1. Hanger hardware and other wood connections shall be designed to carry the capacity of the supporting members. 9. Floor framing (2018 IBC 2308.4.2) 9.1. Joists shall not have less than 1.5 inches of bearing on wood or metal, or less than 3 inches on masonry (2018 IBC 2308.4.2.2). Pre-fabricated wood I-joists shall have minimum bearing according to the manufacturer's recommendations and specifications. 9.2. Joists shall be supported laterally at the ends and at each support by full-depth solid blocking, except where nailed to a header or band or rim joist. Solid blocking shall not be less than 2 inches thick (2018 IBC 2308.4.2.3). 9.3. Where the nominal depth-to-thickness ratio of the framing member exceeds 6:1, there shall be one line of bridging for each 8 feet of span. Bridging shall consist of not less than 1X3 inch lumber, metal bracing, or full-depth solid blocking (2018 IBC 2308.4.6). 9.4. Notches on the ends of joists shall not exceed one-fourth the joist depth. Holes bored in joists shall not be within 2 inches of the top or bottom of the joist. Notches in the top or bottom of joists shall not exceed one-sixth the depth and shall not be located in the middle third of the span (2018 IBC 2308.4.2.4). 9.5. The diameter of holes bored or cut into structural floor members shall not exceed one-third the depth of the member. Holes shall not be closer than 2 inches to the top or bottom of the member, or to any other hole located in the member. Where the member is also notched, the hole shall not be closer than 2 inches to the notch (R502.8.1). 10.Wall construction (2018 IBC 2308.5) 10.1.Studs shall be placed with their wide dimension perpendicular to the wall. Not less than three studs shall be installed at each corner of an exterior wall (2018 IBC 2308.5.2). 10.2.Bearing and exterior wall studs shall be capped with 2-inch thick nominal double top plates, have a width at least equal to the width of the studs, and shall be installed to provide overlapping at corners and intersections with other partitions. End joints in partitions shall be offset at least 48 inches, and shall be nailed with not less than eight 16d common face nails on each side of the joint. (2018 IBC 2308.5.3.2). 10.3.In nonbearing walls and partitions studs shall be capped with no less than a single top plate installed to provide overlapping at corners and at intersections with other walls and partitions. The plate shall be continuously tied at joints by solid blocking at least 16 inches in length and equal in size to the plate or metal ties with spliced sections fastened on each side of the joint (2018 IBC 2308.5.4). 10.4.Studs shall have full bearing on a 2-inch thick nominal (or larger) bottom plate or sill having a width at least equal to the width of the stud (2018 IBC 2308.5.3.1). 10.5.Bearing partitions parallel to joists shall be supported on beams, girders, doubled joists, walls or other bearing partitions. Bearing partitions perpendicular to joists shall not be offset from supporting girders, walls or partitions more than the joist depth unless noted otherwise (2018 IBC 2308.4.5). 10.6.In exterior walls and bearing partitions, any wood stud is permitted to be cut or notched to a depth not exceeding 25 percent of its width. In nonbearing partitions, cutting or notching of studs to a depth of not greater than 40 percent of the width is permitted (2018 IBC 2308.5.9). 10.7.A hole with a diameter not greater than 40 percent of the stud width is permitted to be bored in any wood stud. In no case shall the edge of the bored hole be nearer than 0.625 inches to the edge of the stud. Bored holes shall not be located at the same section of stud as a cut or notch (2018 IBC 2308.5.10). 10.8.Bearing walls without wood sheathing or gypsum wall board on either side shall have blocking between wall studs at mid-height. 10.9.Studs shall be spaced at 16 inches on center for exterior walls, interior bearing walls, and shear walls, unless noted otherwise on the plans. 11.Posts and columns 11.1.Columns shall be as wide as the member they support, laterally supported at all floor levels, and extend down through the structure to the foundation. Provide squash blocking at rim joist below all columns, trimmers, and posts. 11.2.Wood columns and posts shall be framed to provide full end bearing (2018 IBC 2304.10.7). 11.3.Posts and columns shall be supported by concrete piers or metal pedestals projecting above concrete or masonry floors or decks exposed to weather or water splash, or in basements, and which support permanent structures, unless naturally durable or preservative-treated wood is used. The pedestal shall project at least 6 inches above exposed earth and at least 1 inch above floors. 12.Roof and ceiling framing (2018 IBC 2308.7). 12.1.Roof rafters and ceiling joists shall be supported laterally to prevent rotation and lateral displacement in accordance with 2018 IBC 2308.7.8. 12.2.Rafters and joists over three feet long shall be supported using hanger hardware if not supported by bearing. PREFABRICATED METAL PLATE WOOD TRUSSES 1. Prefabricated metal plate wood trusses shall be designed in accordance with 2018 IBC 2303.4 and shall conform to the structural specifications and design criteria. 2. The truss designer shall provide a truss package that includes the following items: 2.1. Design drawings of each individual truss (2018 IBC 2303.4.3). 2.2. Truss placement diagram for the project (2018 IBC 2303.4.2). 2.3. Truss member permanent bracing specification (2018 IBC 2303.4.1.2). 3. Transfer of loads and anchorage of each truss to the supporting structure shall be approved by the registered design professional in responsible charge (2018 IBC 2303.4.4). 4. Truss members and components shall not be cut, notched, drilled, spliced or otherwise altered in any way without written concurrence and approval of the registered design professional in responsible charge. Alterations resulting in the addition of loads to any member (e.g. HVAC equipment) shall not be permitted without verification that the truss is capable of supporting such additional loading (2018 IBC 2303.4.5). STEEL 1. Structural steel work shall conform to 2018 IBC 2205, AISC 341-16, AISC 358-16, and AISC 360-16. 2. Structural shapes 2.1. W: fy = 50 ksi (ASTM A992) 2.2. M,S,C,MC, and L: fy = 36 ksi (ASTM A36) 2.3. HP: fy = 50 ksi (ASTM A572 Gr. 50) 2.4. HSS Rectangular: fy = 46 ksi (ASTM A500 Gr.B) 2.5. HSS Round: fy = 42 ksi (ASTM A500 Gr.B) 2.6. Pipe: fy = 35 ksi (ASTM A53 Gr.B) 2.7. All structural steel shall be properly primed and painted. 3. Plates and bars: fy = 36 ksi (ASTM A36) 4. Structural fasteners 4.1. High-strength bolts: fu = 120-150 ksi (ASTM F3125) 4.2. Common bolts: fu = 60 ksi (ASTM A307 Gr. A) 4.2.1. Nuts (ASTM A563) 4.2.2. Washers (ASTM F436) 4.2.3. Steel to steel bolted connections shall be made with high strength-bolts, unless noted otherwise. Bolts shall carry the identifying mark of three radial lines. All other bolted connections shall be made with bolts and nuts conforming to ASTM A307 unless note otherwise. Bolted connections shall be tightened and shall have washers as required by AISC unless noted otherwise. Enlarging holes shall be accomplished by means of reaming. Do not use a torch on any bolt holes. 4.3. Shear studs: fu = 65 ksi (ASTM A108) 4.4. Threaded rods: fy = 36 ksi (ASTM A36) 4.5. Anchor rods: fy = 36 ksi (ASTM F1554 Gr. 36) 5. Steel deck fy = 36 ksi (ASTM A1008) 6. Welding fu = 70 ksi. 6.1. Welding work shall comply with the American Welding Society (AWS) “Structural Welding Code,” excluding items conflicting with AISC requirements. POST-INSTALLED ANCHORS 1. Epoxy adhesive anchoring systems: 1.1. Concrete: Hilti HIT-RE 500 V3 (ICC ES ESR-3814) or Simpson SET-XP (ICC ES ESR-2508) or USP/Mitek CIA-GEL 7000-C (IAMPO ER-473) 1.2. Masonry (grouted): Hilti HIT RE100 (ICC ES ESR-3829) or Simpson SET (ICC ES ESR-1772) or USP/Mitek CIA-GEL 7000 (ICC ES ESR-1702) 1.3. The calculated strength of anchorage assumes the following conditions for installation: 21 day minimum age of concrete, maximum short term concrete temperature= 150° F, maximum long term concrete temperature= 110° F, dry concrete surface, and normal weight concrete. See adhesive manufacturer notes for minimum temperature requirements. If conditions are otherwise, contact engineer for anchor specifications. 1.4. Steel reinforcement and rods shall be embedded 10 bar diameters unless noted otherwise in the structural drawings and details. Where 10 bar diameters exceeds the member thickness minus minimum cover, steel reinforcement shall be embedded the member thickness minus minimum cover with a standard hook. 1.5. Embedded portions of steel reinforcement and rods shall be clean, straight, and free of mill scale, rust and other coatings that impair the bond with the adhesive. Reinforcement must not be bent after installation (ICC ES ESR-3829). 1.6. Installation of adhesive anchors shall be performed by personnel trained to install adhesive anchors. 2. Mechanical expansion anchors: 2.1. Concrete: Hilti KWIK BOLT TZ (ICC ES ESR-1917) 2.2. Masonry: Hilti KWIK BOLT 3 (ICC ES ESR-1385) 2.3. Expansion anchors shall not be used in tensile load applications (e.g. hold-downs, moment frames). 3. Post-installed anchoring systems shall be installed according to the Manufacturer’s Printed Installation Instructions (MPII). Hole cleaning method shall be based on drilling method and borehole conditions and shall conform to the manufacturer’s instructions. STRUCTURAL OBSERVATIONS 1. Where required by the Provisions of Section 1704.6.1 or 1704.6.2, the owner shall employ a registered design professional to perform structural observations as defined in 2018 IBC 202. Prior to the commencement of observations, the structural observer shall submit to the building official a written statement identifying the frequency and extent of the structural observations. At the conclusion of the work, the structural observer shall submit to the building official a written statement that the site visits have been made and identify any reported deficiencies which have not been resolved (2018 IBC 1704.6). DESIGN CRITERIA Detailed Drafting Emery Garage (Rexburg) 4421020 1. Building code: Idaho Administrative Code (IDAPA) 07.03.01.004 1.1 Model building code: 2012 IRC 1.2 Use and occupancy classification: R (Residential - 1-unit dwelling) 1.3 Risk Category: II (Not occupancy categories I, III, IV) 2. Dead loads 2.1 Roof = 15 psf (10 psf top chord, 5 psf bottom chord) 2.2 Floor = 12 psf 2.3 Walls = 10 psf (interior walls), 12 psf (exterior walls) 3. Live loads -- Roofs (ordinary construction) = 20 psf (or 300 lb point load) -- Residential (1-2 unit dwelling) = 40 psf -- Stairs and exits (residential 1-2 unit dwelling) = 40 psf (or 300 lb point load) 4. Rain load 4.1 Median 15-minute duration rainfall intensity = in/hr 4.2 Median 60-minute duration rainfall intensity = in/hr 5. Snow load 5.1 Ground snow load, Pg = 49 psf (elevation 4836 ft) 5.2 Exposure factor, Ce = 1 5.3 Thermal factor, Ct = 1 5.4 Snow importance factor, Is = 1 5.5 Flat roof snow load, Pf = 34 psf 5.6 Roof slope factor, Cs = 0.63 6. Earthquake design data 6.1 Mapped acceleration parameters 6.1.1 Latitude, Longitude: 43.879, -111.852 6.1.2 MCE short period Ss = 0.35 SDS = 0.35 6.1.3 MCE 1.0 sec. period S1 = 0.14 SD1 = 0.21 6.2 Seismic design category: C 6.3 Seismic importance factor, Ie = 1 6.4 Basic structural system: Bearing wall systems 6.5 Seismic force-resisting system: Light-frame wood walls (wood sheathing) 6.5.1 Response modification factor R = 6.5 6.5.2 System overstrength factor Omega = 3 6.5.3 Deflection amplification factor Cd = 4 6.6 Equivalent Lateral Force Procedure 6.6.1 Seismic response coefficient Cs = 0.05 6.6.2 Seismic base shear (LRFD) V = 2702 lb 7. Wind design data 7.1 Exposure category: C 7.2 Basic design wind speed, V = 105 mph 7.3 Components and cladding pressure = 25 psf (end), 21 psf (interior) 7.4 Internal pressure coeff., Gcpi = 0.18 8. Geotechnical design basis: - Presumptive values, 2018 IBC Table 1806.2 8.2 Site class = D-Default 8.3 Soil notes: None 8.4 Lateral earth pressure 8.4.1 Active = 30 psf/ft 8.4.2 At-rest = 60 psf/ft 8.5 Allowable foundation parameters 8.5.1 Allowable soil bearing, Qa = 1500 psf 8.5.2 Allowable lateral bearing = 150 psf/ft 8.5.3 Coefficient of friction = 0.25 8.6 Minimum frost cover = 36 in. DEFERRED SUBMITTALS 1. The following items are to submitted subsequent to the time of application (deferred submittals): -- Prefabricated metal plate wood trusses - roof (truss manufacturer) 2. Deferred submittals shall have the prior approval of the building official (2018 IBC 107.3.4.1). 3. Deferred submittal documents shall be submitted to the registered design professional in responsible charge who shall review and forward them to the building official with a notation indicating that the documents have been reviewed and found to be in general conformance to the design of the building (2018 IBC 107.3.4.1). 4. Deferred submittal items shall not be installed until the design and submittal documents have been approved by the building official (2018 IBC 107.3.4.1). 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS DE T A I L E D D R A F T I N G E M E R Y G A R A G E ( R E X B U R G ) -- - -- - -- -- 21 OCT 2020 4421020 JMW MCW - - - - - -- - GE N E R A L S T R U C T U R A L N O T E S NTS SN1 P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/21/2020 SIMPSON STRONG WALL WSW24X17 WITH 1" STANDARD STRENGTH BOLTS PER DETAILS 1 & 2 ON SHEET WSW1. EXTEND ANCHORS 11" INTO FOOTING PER DETAIL 1 ON SHEET WSW1. INSTALL (2) #3 HAIRPINS PER DETAIL 5 ON SHEET WSW1. FW3 FT20 TYP. FOR ALL FOUNDATION WALLS (U.N.O.) TYP. FOR ALL FOOTINGS BELOW FOUNDATION WALLS (U.N.O.) FT 1 8 FT18 FT18 SF 4 8 CW TYP. S TYP. V TYP. SIMPSON STRONG WALL WSW24X17 WITH 1" STANDARD STRENGTH BOLTS PER DETAILS 1 & 2 ON SHEET WSW1. EXTEND ANCHORS 11" INTO FOOTING PER DETAIL 1 ON SHEET WSW1. INSTALL (2) #3 HAIRPINS PER DETAIL 5 ON SHEET WSW1. SF54X36SF54X36 FOOTING SCHEDULE MARK WIDTH LENGTH THICKNESS REINFORCEMENT TRANSVERSE LENGTHWISE FT18 18 " CONT. 10 " - (2) #4 FT20 20 " CONT. 10 " - (2) #4 SF48 48 " 48 "12 "(6) #4 (6) #4 SF36X54 36 " 54 " 18 " (9) #4 (6) #4 1. CONTINUOUS FOOTINGS SHALL BE CENTERED UNDER WALLS AND SPOT FOOTINGS SHALL BE CENTERED UNDER COLUMNS UNLESS NOTED OTHERWISE. 2. FOOTINGS AND FOUNDATIONS, EXCAVATIONS, GRADING, AND FILL SHALL COMPLY WITH THE PROVISIONS OF THE GEOTECHNICAL REPORT (SEE GSN) FOUNDATION WALL SCHEDULE MARK HEIGHT WIDTH REINFORCEMENT VERTICAL HORIZONTAL PLACEMENT FW3 3' 8" #4 @ 18" (3) #4 CENTER 1. DOWEL VERTICAL BARS INTO FOOTING. 2. PLACE TOP AND BOTTOM BARS WITHIN 4" OF TOP AND BOTTOM OF WALL. 3. PLACE REINFORCEMENT IN CENTER OF WALL OR NEAR EACH FACE, AS NOTED. 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS DE T A I L E D D R A F T I N G E M E R Y G A R A G E ( R E X B U R G ) -- - -- - -- -- 21 OCT 2020 4421020 JMW MCW - - - - - -- - FO O T I N G A N D F O U N D A T I O N P L A N 1/4" = 1'-0" S0-0FOOTING AND FOUNDATION PLAN 1/4" = 1'-0" P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/21/2020 SIMPSON STRONG WALL WSW24X17. BASE CONNECTION PER DETAIL 4 AND TOP CONNECTION PER DETAIL 6 OR 7 ON SHEET WSW2. SEE FOUNDATION PLAN FOR ANCHORAGE. SW 1 NO H O L D - D O W N S R E Q U I R E D SW 1 SW1 B FH SW2 AA FH A A C C CJ C C CJ GTTYP. ADTYP. BSTYP. CI SHORT WALL BETWEEN TRUSSESY Y B SIMPSON STRONG WALL WSW24X17. BASE CONNECTION PER DETAIL 4 AND TOP CONNECTION PER DETAIL 6 OR 7 ON SHEET WSW2. SEE FOUNDATION PLAN FOR ANCHORAGE. SHEAR WALL SCHEDULE MARK SHEATHING EDGE NAILING ABUTTING PANEL EDGE FRAMING ANCHORAGE SOLE PLATE SILL PLATE SW1 7/16" 8d @ 6"2X 10d @ 12"1/2" A.B. @ 32" SW2 7/16" 8d @ 4"2X 10d @ 12" 1/2" A.B. @ 32" 1. SHEATHING SHALL CONSIST OF WOOD STRUCTURAL PANELS (SEE GSN). 2. UNLESS NOTED ON DRAWINGS, EXTERIOR STUDS SHALL BE SPACED AT 16" O.C. 3. SHEATHING NAILS SHALL BE COMMON OR GALVANIZED BOX NAILS. - FIELD NAIL SPACING SHALL BE 12" FOR STUDS SPACED 16" O.C. OR LESS AND 6" O.C. FOR STUDS SPACED AT 24" O.C. 4. FOR SW1 ONLY, EDGE NAILS MAY BE SUBSTITUTED WITH 1-1/2" 16 GAGE STAPLES SPACED AT 3" O.C. AND FIELD NAILS MAY BE SUBSTITUTED WITH 16 GAGE STAPLES AT 12" O.C. 5. ANCHORAGE NAILS SHALL BE COMMON NAILS. 6. ANCHOR BOLTS SHALL HAVE A 3X3X0.229" WASHER AND 7" MIN EMBEDMENT. THE WASHER SHALL EXTEND TO WITHIN 1/2" FROM THE SHEATHING. HOLD-DOWN SCHEDULE MARK HOLD-DOWN MINIMUM FASTENERS ANCHOR POST A LSTHD8 10d X 2-1/2" (.148 X 2-1/2")STRAP 8" EMBED.(2) 2X POST B STHD10 10d X 2-1/2" (.148 X 2-1/2")STRAP 10" EMBED.(2) 2X POST C STHD14 10d X 2-1/2" (.148 X 2-1/2")STRAP 14" EMBED.(2) 2X POST 1. HOLD-DOWNS SHALL BE SIMPSON STRONG-TIE OR EQUIVALENT. 2. SHEAR WALL EDGE NAILING SHALL BE TO HOLD-DOWN POST. 3. STHD STRAPS SHALL BE "RJ" TYPE AT RIM JOIST LOCATIONS. 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS DE T A I L E D D R A F T I N G E M E R Y G A R A G E ( R E X B U R G ) -- - -- - -- -- 21 OCT 2020 4421020 JMW MCW - - - - - -- - SH E A R W A L L P L A N 1/4" = 1'-0" S0-1SHEAR WALL PLAN 1/4" = 1'-0" P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/21/2020 EXTEND HEADER - SEE DETAIL "CJ" FOR CORRECT HEADER INSTALLATION. RB 0 1 RB 0 1 RB 0 1 RB 0 1 RB 0 1 RB 0 1 RB 0 1 RB 0 1 RB 0 2 RB 0 2 RB 03 RB 03 RB 05RB 04 RB 0 6 P 04 P 04 SP ZA (B O T T O M F L U S H ) GUTYP. IA TYP. AP TYP. Q TYP. XH TYP. BE A R I N G W A L L T 15 T 1 5 WOOD TRUSS LOADS GROUND SNOW LOAD, Pg = 49 PSF FLAT ROOF SNOW LOAD = 34 PSF TOP CHORD DEAD LOAD = 10 PSF BOTTOM CHORD DEAD LOAD = 5 PSF 1. DESIGN SNOW LOADS SHALL BE IN ACCORDANCE WITH ASCE 7-16 CHAP.7 (2018 IBC 1608.1) SHEATHING SCHEDULE TYPE THICKNESS FLOOR 3/4" OSB (48/24 SPAN RATING) ROOF 7/16" OSB (24/16 SPAN RATING) 1. SHEATHING PERPENDICULAR TO SUPPORTS. 2. FLOOR SHEATHING NAILED & GLUED TO SUPPORT 3. 8d COMMON NAILS 6" O.C. (EDGES) 12" O.C. (FIELD) 4. NAILING NO CLOSER THAN 3/8" FROM PANEL EDGE POST SCHEDULE MARK TYPE P 04 (4) 2X POST T 15 (1) TRIM (3) KING 1. PARALLEL STRAND LUMBER (PSL) 1.8E 2. STEEL PIPE (PIPE STD) A53 3. STEEL HOLLOW SECTION (HSS) A500 4. STEEL COLUMNS REQUIRE BEARING PLATES 5. CONTINUE POSTS TO FDN / STRUCT MEMBER BEAM SCHEDULE MARK TYPE RB 01 (3) 2 X 6 RB 02 (2) 2 X 6 RB 03 (2) 2 X 6 RB 04 (2) 1-3/4 X 11-7/8 LVL RB 05 (3) 2 X 8 RB 06 5-1/8 X 30 GLB 1. DIMENSIONAL LUMBER DF #2 U.N.O. 2. LAMINATED VENEER LUMBER (LVL) 2.0E 3. GLUED-LAMINATED TIMBER (GLB) 24F-1.8E 4. STEEL W-SHAPES A992-50 5. SUFFIXES (A, B, ETC.) DENOTE ALTERNATIVES FOR THE SPECIFIED BEAM 6. ALL HEADERS IN BEARING WALLS TO HAVE MIN. (1) TRIMMER & (1) KING STUD U.N.O. ALL OTHER BEAMS AND GIRDER TRUSSES TO HAVE MIN. (2) 2X SUPPORTS U.N.O. 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS DE T A I L E D D R A F T I N G E M E R Y G A R A G E ( R E X B U R G ) -- - -- - -- -- 21 OCT 2020 4421020 JMW MCW - - - - - -- - RO O F F R A M I N G P L A N 1/4" = 1'-0" S1-0ROOF FRAMING PLAN 1/4" = 1'-0" P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/21/2020 TRUSSES A35 CLIPS WALL SHEATHING 2X BLOCKING (A35 AND 2X BLOCKING NOT REQUIRED WHERE HANGER ATTACHES TO RIM BOARD OR 2X MEMBER) 2X WALL STUD 2X STUD WALL (2) A35 CLIPS 2X BLOCKING (NOT REQUIRED WHERE HANGER ATTACHES TO BEAM OR RIM BOARD) TRUSS HANGER (SEE MANUFACTURER) TRUSS BOTTOM CHORD 2X BLOCKING BETWEEN TRUSSES ROOF SHEATHING (SEE STRUCTURAL) TRUSS TOP CHORD WOOD TRUSS - WALL/BEAM NO SCALEZA PLAN VIEW SECTION ROOF RAFTER WOOD TRUSS H2.5A AT EACH RAFTER BEARING ROOF RAFTER (SEE STRUCTURAL) DIAPHRAGM BOUNDARY NAILING FULL-HEIGHT SOLID BLOCKING (EVERY THIRD BLOCK MAY BE TURNED FLATWISE FOR VENTILATION) NO SCALE ROOF FRAMING - BLOCKING (150 PLF UNIT SHEAR)Q MULTI-PLY TRUSS TO TOP PLATE CONNECTION TRUSS UPLIFT TIE-DOWN <520 LB (2) H2.5A <650 LB SDWC15600 SCREW <1040 LB H10A OR H10A-2 <1310 LB HTS16 UPLIFTS TO BE PROVIDED BY TRUSS MANUFACTURER UPLIFT CAPACITIES ARE BASED ON DOUGLAS FIR H1 OR SDWC15600 AT EACH SINGLE TRUSS BEARING (SEE TABLE FOR MULTI-PLY TRUSSES.) WOOD TRUSS DIAPHRAGM BOUNDARY NAILING 10dx3" @ 6" O.C. FULL-HEIGHT SOLID BLOCKING OR PREFABRICATED TRUSS BLOCKING (FOR SOLID BLOCKS, EVERY THIRD BLOCK MAY BE TURNED FLATWISE FOR VENTILATION) VPA CONNECTOR OR ATTACH RAFTER TO BEVELED PLATE WITH (3) 10d NAILS AT EACH RAFTER (BEVELED PLATE TO TOP PLATE NAILING TO MATCH DOUBLE TOP PLATE NAILING) WEB STIFFENERS REQUIRED FOR I-JOIST RAFTERS A35 OR RBC CLIP AT EACH BLOCK NO SCALES FOUNDATION WALL CORNER DOWELS TYP. @ FOOTINGS & FOUNDATION CORNER INTERSECTION REQUIRED LAP LENGTH CONCRETE 12 BAR DIA. 40 BAR DIA. HORIZONTAL REINFORCING AS CALLED OUT IN GENERAL STRUCTURAL NOTES OR STRUCTURAL DRAWINGS HOOK TYPE SPLICE HO O K 12" 24" MASONRY 20 BAR DIA. 48 BAR DIA. MIN. SPLICE FOUNDATION WALL - CORNER & INTERSECTION REINFORCING SE E G E N E R A L S T R U C T U R A L N O T E S MI N . F R O S T D E P T H 3" C L R . 3" 2X STUD WALL ANCHOR BOLT (SEE SHEAR WALL SCHEDULE FOR SPACING) WITH 3X3X0.229" PL WASHER CONCRETE SLAB ROUGHENED SURFACE WITH 1/4" MIN. IRREGULARITIES DOWELS TO MATCH VERTICAL WALL REINFORCING CONCRETE FOOTING (SEE STRUCTURAL) SHEATHING (SEE SHEAR WALL SCHEDULE) 2X TREATED SILL PLATE FOUNDATION WALL - SLAB ON GRADE NO SCALEV CONCRETE FOUNDATION WALL (SEE STRUCTURAL) HOLD-DOWN (SEE STRUCTURAL) SEE SHEAR WALL SCHEDULE FOR ANCHOR BOLTS SIZE AND SPACING ADDITIONAL STRAPPING AND BLOCKING AROUND OPENINGS ARE NOT REQUIRED. WINDOW OPENING (WHERE OCCURS) DOOR OPENING (WHERE OCCURS) PROVIDE EDGE NAILING ALONG FULL HEIGHT OF HOLD-DOWN POST SEE STRUCTURAL PLAN FOR SHEAR WALL EXTENT AND REQUIREMENTS SHEAR WALL - PERFORATED NO SCALEY POST (SEE HOLD-DOWN SCHEDULE) EMBEDDED FOUNDATION STRAP (SEE HOLD-DOWN SCHEDULE) RIM BOARD WHERE OCCURS CL E A R S P A N 17 " M A X I M U M NA I L E D P O R T I O N HORIZONTAL REINFORCEMENT AT TOP OF FOUNDATION (SEE FOUNDATION WALL SCHEDULE) 1/2" MIN. FROM CORNER HOLD-DOWN - FOUNDATION STRAP NO SCALEAD 4" TYP. 1" T Y P . 4'-0" MINIMUM BETWEEN SPLICES TOP PLATE TO LOWER PLATE: 12 - 16d NAILS (2 ROWS OF 6) LOWER PLATE TO TOP OF STUDS: 2 - 16d NAILS AT EACH STUD 8'-0" MINIMUM TO NEXT LAP NOTE: WHERE DOUBLE TOP PLATE IS CUT DUE TO INTERSECTING BEAMS, WALLS, ETC. PROVIDE (2) CS16 STRAPS ACROSS CUT WITH 12" END LENGTHS DIAPHRAGM - TOP PLATE SPLICE NO SCALEAP LE N G T H 8" MIN. MINIMUM EDGE DISTANCE HOLD-DOWN (MAY BE PLACED ABOVE FLOOR JOISTS USING COUPLER NUT AND EXTENSION ROD) DRILL AND EPOXY A36 THREADED ROD (SEE TABLE FOR DIAMETER, EMBEDMENT LENGTH AND MINIMUM EDGE DISTANCE) FOUNDATION WALL NOTES: 1. EPOXY SHALL BE SIMPSON SET-XP OR EQUIVALENT. SEE MANUFACTURER FOR INSTALLATION REQUIREMENTS. 2. ALL PRODUCTS ARE SIMPSON DESIGNATIONS, EQUIVALENT ANCHORS AND HOLD-DOWNS ARE PERMITTED. EPOXY RETROFIT FOR MISPLACED STHD REPLACEMENT EPOXY ANCHORREPLACEMENT HOLD-DOWN SPECIFIED STRAP DIA. LENGTH MIN. EDGE DIST. HDU2 5/8" 8" 1-3/4"LSTHD8 HDU4 5/8" 12" 1-3/4"STHD10 HDU5 5/8" 16" 1-3/4"STHD14 NO SCALEBSRETROFIT EPOXY ANCHOR IN FOUNDATION WALL 8d @ 4" O.C. BLOCKING BETWEEN TRUSSES MONO TRUSSES SET-BACK GABLE TRUSS PROVIDE 2X BLOCKING IN TRUSS 10d @ 4" O.C. FLOOR SYSTEM (SEE STRUCTURAL) 8d @ 4" O.C. BLOCKING OR LEDGER REQUIRED MONO TRUSSES OR RAFTERS 2X STUD WALL BLOCKING REQUIRED BETWEEN STUDS FLOOR SHEATHING CONTINUOUS SHEATHING REQUIRED 10d @ 4" O.C. NO SCALECISHEAR TRANSFER - SET-BACK WALL/GABLE - LOWER ROOF SET-BACK WALL SET-BACK GABLE EXTENT OF HEADER 10 ' - M A X H E I G H T (2) ROWS 16d SINKER NAILS @ 3" O.C. 3/8" MIN. THICKNESS WOOD STRUCTURAL PANEL SHEATHING HOLD-DOWN (SEE STRUCTURAL) SHEATHING FILLER IF NEEDED 2' TO 18' (CLEAR SPAN) (2) CS16 OR (1) MST27 STRAPS OPPOSITE SHEATHING IF PANEL SPLICE IS NEEDED IT SHALL OCCUR WITHIN 24" OF MID-HEIGHT, 2X BLOCKING REQUIRED. (2) 2X MIN. MIN. 3"X3"X0.229" PLATE WASHER(S) (2) 1/2" ANCHOR BOLTS OR (1) 5/8" ANCHOR BOLT WITH 7" MIN. EMBED. HOLD-DOWNS (SEE STRUCTURAL) ATTACH SHEATHING TO TOP PLATE WITH 8d NAILS AT 4" O.C. STAGGERED 3" X 11-1/4" MIN. HEADER (SEE STRUCTURAL)2' - M A X P O N Y WA L L H E I G H T 12 ' - M A X T O T A L W A L L H E I G H T FASTEN SHEATHING TO HEADER WITH 8d COMMON NAILS IN 3" GRID PATTERN AS SHOWN AND 3" O.C. IN ALL FRAMING (STUDS AND SILLS) TYP. FULL-HEIGHT STUD APA PORTAL FRAME - CONCRETE FOUNDATION NO SCALECJ OUTSIDE ELEVATION SECTION FO O T I N G D E P T H (S E E S T R U C T U R A L ) 4" FOOTING WIDTH (SEE STRUCTURAL) 3" 3" 3" 3" NOTE: FASTENERS IN PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED WOOD SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE, OR COPPER. LENGTHWISE REINFORCEMENT (SEE STRUCTURAL) CONCRETE NAILS @ 16" O.C. (ANCHOR BOLTS REQUIRED AT SHEAR WALLS PER SHEAR WALL SCHEDULE) 2X STUD WALL CONCRETE SLAB (WHERE OCCURS) 1 1 AT OPTIONAL MONOLITHIC FOOTING NO SCALECWBEARING WALL - INTERIOR FOOTING SEE STRUCTURAL PLAN FOR SHEAR WALL EXTENT AND REQUIREMENTS SEE SHEAR WALL SCHEDULE FOR ANCHOR BOLTS SIZE AND SPACING HOLD-DOWN IF REQUIRED (SEE STRUCTURAL) WINDOW OPENING (WHERE OCCURS) DOOR OPENING (WHERE OCCURS) CS16 (32" LONG) WITH SOLID BLOCKING AT TOP OF OPENING CS16 (32" LONG) WITH SOLID BLOCKING AT BOTTOM OF OPENING CS16 (32" LONG) WITH SOLID BLOCKING AT TOP OF OPENING PROVIDE EDGE NAILING ALONG FULL HEIGHT OF HOLD-DOWN POST SHEAR WALL - FORCE TRANSFER AROUND OPENINGS NO SCALEFH SHEAR WALL - ROOF DIAPHRAGM CONNECTION NO SCALEGT E.N. = EDGE NAILING REQUIRED WOOD STRUCTURAL PANELS (SEE SCHEDULE) 2X WALL DOUBLE TOP PLATE ABUTTING PANEL EDGE FRAMING MEMBER (SEE SCHEDULE FOR SIZE) 2X BLOCKING REQUIRED AT ALL PANEL SPLICES FIELD NAILING AT ALL INTERMEDIATE WALL STUDS (SEE SCHEDULE) EDGE NAILING AT ALL PANEL EDGES (SEE SCHEDULE) NAILS SHALL BE LOCATED AT LEAST 3/8" FROM PANEL EDGE 2X WALL SILL/SOLE PLATE (SEE SCHEDULE FOR ANCHORAGE) PROVIDE STAGGERED EDGE NAILING AT DOUBLE TOP PLATE REGARDLESS OF PANEL EDGE LOCATION ROOF OR FLOOR FRAMING CONTINUOUS PANEL JOINT EDGE NAILING AT PANEL EDGES (SEE SHEATHING SCHEDULE) DIAPHRAGM BOUNDARY NAILING (MATCH PANEL EDGE NAILING) 4'X8' WOOD STRUCTURAL PANEL (SEE SHEATHING SCHEDULE) FIELD NAILING AT INTERMEDIATE FRAMING (SEE SHEATHING SCHEDULE) WOOD STRUCTURAL PANEL DIAPHRAGM - UNBLOCKED NO SCALEGU HEADER (SEE STRUCTURAL) TWO PLIES: 10d COMMON (0.148X3") NAILS @ 24" O.C. THREE OR MORE PLIES: FACE NAILING 10d COMMON (0.148X3") NAILS @ 6" O.C. STAGGERED KING STUD MIN. (1) PLY U.N.O. TRIMMER(S) (SEE STRUCTURAL) (4)16d END NAILS OR (4) 8d TOE NAILS WOOD BEAM - WALL HEADER FRAMING NO SCALEIA BEAM OR GIRDER TRUSS (SEE STRUCTURAL PLANS) BEAM OR GIRDER TRUSS (SEE STRUCTURAL PLANS) DOUBLE TOP PLATE DOUBLE TOP PLATE DOUBLE TOP PLATE (2) CS16 STRAPS 24" LONG (2) CS16 STRAPS 24" LONG SLIDE STRAP BETWEEN BEAM AND WALL BEAM OR GIRDER TRUSS (SEE STRUCTURAL PLANS) (2) CS16 STRAPS (10) -10d NAILS EACH END OF EACH CS16 (CUT TO REQUIRED LENGTH) OR DSC OR EQUIVALENT DIAPHRAGM - CHORD / COLLECTOR STRAP NO SCALELF FLUSH DROPPED OFFSET 2X STUD WALL SOLE PLATE FLOOR SHEATHING (SEE STRUCTURAL) FLOOR SYSTEM (SEE STRUCTURAL)JOIST HANGER 2X BLOCKING BETWEEN JOISTS WITH (2) ROWS OF 10d COMMON NAILS @ 8" O.C. DIAPHRAGM BOUNDARY NAILING CONTINUOUS SHEAR WALL SHEATHING TO BOTTOM OF BEAM (SEE STRUCTURAL FOR SHEAR WALL SHEATHING AND NAILING) 2X STUD WALL SOLE PLATE FLOOR SHEATHING (SEE STRUCTURAL) FLOOR SYSTEM (SEE STRUCTURAL) BEAM (SEE STRUCTURAL) DIAPHRAGM BOUNDARY NAILING CONTINUOUS SHEAR WALL SHEATHING TO BOTTOM OF BEAM (SEE STRUCTURAL FOR SHEAR WALL SHEATHING AND NAILING) BEAM (SEE STRUCTURAL) SHEAR WALL EDGE NAILING PER SHEAR WALL REQUIREMENTS SHEAR WALL EDGE NAILING PER SHEAR WALL REQUIREMENTS BEAM UPSET IN WALL NO SCALESP 2X LEDGER WITH (2) ROWS OF 10d COMMON NAILS @ 8" O.C. SHEATHING CONTINUOUS ACROSS JOINT OR ATTACH GABLE END TRUSS TO TOP PLATE WITH 10dX3" @ 6" O.C. TOE NAILING END WALL 2X6 BRACE @ 48" O.C. WOOD TRUSS ROOF SHEATHING GABLE END WOOD TRUSS ATTACH BRACE TO BLOCKING WITH (5) 10d NAILS 2X4 BLOCKING WITH (2) 10d NAILS @ EACH END 8d NAILS @ 6" O.C. WOOD TRUSS - WOOD WALL GABLE END BRACING NO SCALEXH 1 (MAX.) 1 (2) A34 OR (2) GBC @ EACH BRACE 2X BLOCKING FOR TWO BAYS AT TOP OF DIAGONAL BRACE 801.224.0050 801.229.9020 info@acuteengineering.com 744 S 400 E Orem, UT 84097 Phone Fax ORIGINAL PROJECT # DRAWN BY: CHECKED BY: SCALE: DATE: THESE STRUCTURAL DRAWINGS ARE BASED ON ARCHITECTURAL DRAWINGS. SEE CURRENT ISSUE OR REVISION DATE. DIMENSIONS AND ELEVATIONS ARE SUPPLIED BY THE ARCHITECT. THEY MAY BE PROVIDED ON THE STRUCTURAL PLANS AND DETAILS FOR THE CONVENIENCE OF THE CONTRACTOR. VERIFY DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL DRAWINGS. ISSUES / REVISIONS DE T A I L E D D R A F T I N G E M E R Y G A R A G E ( R E X B U R G ) -- - -- - -- -- 21 OCT 2020 4421020 JMW MCW - - - - - -- - ST R U C T U R A L D E T A I L S NTS SD1 P R O F E S S I O N A L E N G I N E E RLICENSED S T A T E O F I D A H O B R A NDON T O D D D E C KER 19632 10/21/2020 5 STRONG-WALL ® WSW ANCHORAGE - TYPICAL SECTIONS 218" TOP OF CONCRETE 218" 2x2 112" (2) 7/8" WSW-AB for WSW12 and WSW18 (2) 1" WSW-AB for WSW24 (2) 7/8" WSW-AB for WSW12 and WSW18 (2) 1" WSW-AB for WSW24 (2) 7/8" WSW-AB for WSW12 and WSW18 (2) 1" WSW-AB for WSW24 (2) 7/8" WSW-AB for WSW12 and WSW18 (2) 1" WSW-AB for WSW24 WSW-RT EXTERIOR INSTALLATION WSW-RTPF PANEL FORM INSTALLATION WSW-RT INTERIOR INSTALLATION WSW-RTBL BRICK LEDGE INSTALLATION CURB OR STEMWALL FOUNDATION SLAB ON GRADE FOUNDATION 218" de INTERIOR FOUNDATION NOTES: 1. SEE 2/WSW1 FOR DIMENSIONS AND ADDITIONAL NOTES. 2. SEE 5/WSW1 FOR SHEAR REINFORCEMENT WHEN REQUIRED. 3. MAXIMUM H = l e - de. SEE 3/WSW1 AND 4/WSW1 FOR l e. W 218" de H 218" de H 218" de BRICK LEDGE FOUNDATION WSW-AB SHEAR REINFORCEMENT PER 5/WSW1 WHEN REQUIRED. MINIMUM CURB/STEMWALL WIDTH PER 5/WSW1. WSW-AB SHEAR REINFORCEMENT PER 5/WSW1 WHEN REQUIRED. MINIMUM CURB/STEMWALL WIDTH PER 5/WSW1. WSW-AB SHEAR REINFORCEMENT PER 5/WSW1 WHEN REQUIRED. WSW-AB REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. 1/2 W 1/2 W W 1/2 W 1/2 W W 1/2 W 1/2 W W 1/2 W 1/2 W WSW ANCHORAGE SOLUTIONS FOR 2500 PSI CONCRETE DESIGN CRITERIA CONCRETE CONDITION ANCHOR STRENGTH WSW-AB7/8 ANCHOR BOLT WSW-AB1 ANCHOR BOLT ASD ALLOWABLE TENSION (lb.) W (in.) de (in.) ASD ALLOWABLE TENSION (lb.) W (in.) de (in.) SEISMIC CRACKED STANDARD 11,900 27 9 16,100 33 11 13,100 29 10 17,100 35 12 HIGH STRENGTH 24,900 43 15 33,000 51 17 27,100 46 16 35,300 54 18 UNCRACKED STANDARD 12,500 24 8 15,700 28 10 13,100 25 9 17,100 30 10 HIGH STRENGTH 25,300 38 13 32,300 44 15 27,100 40 14 35,300 47 16 WIND CRACKED STANDARD 5,100 14 6 6,200 16 6 8,700 20 7 11,400 24 8 13,100 27 9 17,100 32 11 HIGH STRENGTH 15,900 30 10 21,100 36 12 18,400 33 11 27,300 42 14 23,100 38 13 31,800 46 16 27,100 42 14 35,300 50 17 UNCRACKED STANDARD 5,000 12 6 6,400 14 6 9,300 18 6 12,500 22 8 13,100 23 8 17,100 28 10 HIGH STRENGTH 15,200 25 9 21,900 32 11 19,900 30 10 26,400 36 12 24,000 34 12 31,500 40 14 27,100 37 13 35,300 43 15 24 7/8" OR 1" HIGH STRENGTH ROD HEAVY HEX NUT FIXED IN PLACE ON ALL WSW ANCHOR BOLTS HX HX ON EXTENSION KIT TOP OF CONCRETE WSW-HSR HIGH STRENGTH COUPLER NUT WSW-AB CUT TO LENGTH AS NECESSARY WSW-HSR AND WSW-AB ASSEMBLY 1 WSW-HSR_KT HIGH STRENGTH COUPLER NUT TOP OF CONCRETE LENGTH 218" 218" ASSEMBLY l e = WSW-AB le + WSW-HSR l e + 218" WSW PANEL MODEL MODEL NO. DIAMETER LENGTH le WSW12 AND WSW18 WSW-HSR7/8x24KT 7/8"24" 22" WSW-HSR7/8x36KT 7/8" 36" 34" WSW24 WSW-HSR1x24KT 1" 24" 22" WSW-HSR1x36KT 1" 36" 34" le 36 HEAVY HEX NUT HEAVY HEX NUT FIXED IN PLACE ON ALL WSW-AB ANCHOR BOLTS HS HS ON HIGH STRENGTH MODELS 1 LENGTH 218" LENGTH DIAMETER HEAVY HEX NUT PLATE WASHER WSW PANEL MODEL MODEL NO. DIAMETER LENGTH le WSW12 AND WSW18 WSW-AB7/8x24 7/8" 24" 20" WSW-AB7/8x24HS 7/8" 24" 20" WSW-AB7/8x30 7/8"30" 26" WSW-AB7/8x30HS 7/8"30" 26" WSW-AB7/8x36HS 7/8" 36" 32" WSW24 WSW-AB1x24 1" 24" 20" WSW-AB1x24HS 1" 24"20" WSW-AB1x30 1"30" 26" WSW-AB1x30HS 1" 30" 26" WSW-AB1x36HS 1" 36" 32" le STRONG-WALL ® WOOD SHEARWALL SHEAR ANCHORAGE MODEL Lt OR Lh (in.) SEISMIC 3 WIND 4 SHEAR REINFORCEMENT MINIMUM CURB/ STEMWALL WIDTH (in.) SHEAR REINFORCEMENT MINIMUM CURB/ STEMWALL WIDTH (in.) ASD ALLOWABLE SHEAR LOAD, V (lb.) 6 UNCRACKED CRACKED WSW12 1014 (1) #3 HAIRPIN 85 SEE NOTE 6 6 1,035 740 WSW18 15 (1) #3 HAIRPIN 85 (1) #3 HAIRPIN 6 HAIRPIN REINFORCEMENT ACHIEVES MAXIMUM ALLOWABLE SHEAR LOAD OF THE WSWWSW24 19 (2) #3 HAIRPINS 85 (1) #3 HAIRPIN 6 NOTES: 1. SHEAR ANCHORAGE DESIGNS CONFORM TO ACI 318-11 AND ACI 318-14 AND ASSUME MINIMUM 2,500 PSI CONCRETE. 2. SHEAR REINFORCEMENT IS NOT REQUIRED FOR INTERIOR FOUNDATION APPLICATIONS (PANEL INSTALLED AWAY FROM EDGE OF CONCRETE), OR BRACED WALL PANEL APPLICATIONS. 3. SEISMIC INDICATES SEISMIC DESIGN CATEGORY C THROUGH F. DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C MAY USE WIND ANCHORAGE SOLUTIONS. 4. WIND INCLUDES SEISMIC DESIGN CATEGORY A AND B AND DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C. 5. WHERE NOTED, MINIMUM CURB/STEMWALL WIDTH IS 6 INCHES WHEN STANDARD STRENGTH ANCHOR BOLT IS USED. 6. USE (1) #3 TIE FOR WSW12 WHEN PANEL DESIGN SHEAR FORCE EXCEEDS TABULATED ANCHORAGE ALLOWABLE SHEAR LOAD. 7. #4 GRADE 40 SHEAR REINFORCEMENT MAY BE SUBSTITUTED FOR WSW SHEAR ANCHORAGE SOLUTIONS. 5" MIN. FOR WSW-AB7/8 6" MIN FOR WSW-AB1 5" MIN. FOR WSW-AB7/8 6" MIN FOR WSW-AB1 5" MIN. FOR WSW-AB7/8 6" MIN FOR WSW-AB1 5" MIN. FOR WSW-AB7/8 6" MIN FOR WSW-AB1 NOTES: 1. ANCHORAGE DESIGNS CONFORM TO ACI 318-11 APPENDIX D AND ACI 318-14 WITH NO SUPPLEMENTARY REINFORCEMENT FOR CRACKED OR UNCRACKED CONCRETE AS NOTED. 2. ANCHOR STRENGTH INDICATES REQUIRED GRADE OF WSW-AB ANCHOR BOLT. STANDARD (ASTM F1554 GRADE 36) OR HIGH STRENGTH (HS) (ASTM A449). 3. SEISMIC INDICATES SEISMIC DESIGN CATEGORY C - F. DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C MAY USE WIND ANCHORAGE SOLUTIONS. SEISMIC ANCHORAGE DESIGNS CONFORM TO ACI 318-11 SECTION D.3.3.4.3 AND ACI 318-14 SECTION 17.2.3.4.3. 4. WIND INCLUDES SEISMIC DESIGN CATEGORY A AND B AND DETACHED 1 AND 2 FAMILY DWELLINGS IN SDC C. 5. FOUNDATION DIMENSIONS ARE FOR ANCHORAGE ONLY. FOUNDATION DESIGN (SIZE AND REINFORCEMENT) BY OTHERS. THE REGISTERED DESIGN PROFESSIONAL MAY SPECIFY ALTERNATE EMBEDMENT, FOOTING SIZE OR ANCHOR BOLT. 6. REFER TO 1/WSW1 FOR d e. WSW ANCHORAGE SOLUTIONS FOR 3000 PSI CONCRETE DESIGN CRITERIA CONCRETE CONDITION ANCHOR STRENGTH WSW-AB7/8 ANCHOR BOLT WSW-AB1 ANCHOR BOLT ASD ALLOWABLE TENSION (lb.) W (in.) de (in.) ASD ALLOWABLE TENSION (lb.) W (in.) de (in.) SEISMIC CRACKED STANDARD 12,300 26 9 16,000 31 11 13,100 28 10 17,100 33 11 HIGH STRENGTH 25,200 41 14 32,700 48 16 27,100 43 15 35,300 51 17 UNCRACKED STANDARD 12,000 22 8 16,300 27 9 13,100 24 8 17,100 28 10 HIGH STRENGTH 25,300 36 12 32,700 42 14 27,100 38 13 35,300 44 15 WIND CRACKED STANDARD 5,000 13 6 5,600 14 6 8,800 19 7 10,200 21 7 13,100 25 9 17,100 30 10 HIGH STRENGTH 15,700 28 10 20,100 33 11 19,200 32 11 25,300 38 13 23,200 36 12 32,300 44 15 27,100 40 14 35,300 47 16 UNCRACKED STANDARD 5,500 12 6 6,200 13 6 8,500 16 6 12,800 21 7 13,100 22 8 17,100 26 9 HIGH STRENGTH 16,600 25 9 21,800 30 10 19,700 28 10 25,200 33 11 24,000 32 11 31,700 38 13 27,100 35 12 35,300 41 14 WSW ANCHORAGE SOLUTIONS FOR 4500 PSI CONCRETE DESIGN CRITERIA CONCRETE CONDITION ANCHOR STRENGTH WSW-AB7/8 ANCHOR BOLT WSW-AB1 ANCHOR BOLT ASD ALLOWABLE TENSION (lb.) W (in.) de (in.) ASD ALLOWABLE TENSION (lb.) W (in.) de (in.) SEISMIC CRACKED STANDARD 12,600 23 8 16,000 27 9 13,100 24 8 17,100 29 10 HIGH STRENGTH 24,800 36 12 32,100 42 14 27,100 38 13 35,300 45 15 UNCRACKED STANDARD 12,700 20 7 15,700 23 8 13,100 21 7 17,100 25 9 HIGH STRENGTH 24,600 31 11 32,500 37 13 27,100 34 12 35,300 39 13 WIND CRACKED STANDARD 5,400 12 6 6,800 14 6 8,300 16 6 11,600 20 7 13,100 22 8 17,100 26 9 HIGH STRENGTH 15,300 24 8 21,400 30 10 19,300 28 10 25,800 34 12 23,600 32 11 31,000 38 13 27,100 36 12 35,300 42 14 UNCRACKED STANDARD 6,800 12 6 6,800 12 6 9,400 15 6 12,400 18 6 13,100 19 7 17,100 23 8 HIGH STRENGTH 16,800 22 8 21,600 26 9 20,300 25 9 26,700 30 10 24,100 28 10 32,200 34 12 27,100 31 11 35,300 36 12 1/2 W 1/2 W W STRONG-WALL ® WOOD SHEARWALL WSW-AB SLAB OR CURB AND SURROUNDING FOUNDATION NOT SHOWN FOR CLARITY HAIRPIN INSTALLATION (GARAGE CURB SHOWN. OTHER FOOTING TYPES SIMILAR.) ANCHOR BOLT #3 HAIRPIN (#3 TIE SIMILAR). SEE TABLE FOR REQUIRED QUANTITY. ANCHOR BOLT #3 HAIRPIN (#3 TIE SIMILAR). SEE TABLE FOR REQUIRED QUANTITY. 112" CLR A A 4" MIN 3" LtLh MIN 3" FIELD TIE AND SECURE DURING CONCRETE PLACEMENT. OVERLAP VARIES WITH BOLT SPACING. #3 HAIRPIN, GRADE 60 REBAR (MIN.) ANCHOR BOLT 112" CLR FIELD TIE AND SECURE DURING CONCRETE PLACEMENT. #3 TIE, GRADE 60 REBAR (MIN.) ANCHOR BOLT HAIRPIN SHEAR REINFORCEMENT TIE SHEAR REINFORCEMENT SECTION A-A REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. 1 3 4 6 2 WSW ANCHOR BOLTS WSW ANCHOR BOLT EXTENSION WSW ANCHOR BOLT TEMPLATES STRONG-WALL® WSW SHEAR ANCHORAGE SCHEDULE AND DETAILSSTRONG-WALL ® WOOD SHEARWALL TENSION ANCHORAGE SCHEDULE 2,500, 3,000 AND 4,500 PSI FOUNDATION PLAN VIEW 1/2 W1/2 W STRONG-WALL ® WOOD SHEARWALL TOP PLATES RIM JOIST, BEAM, OR BLOCKING IF APPLICABLE HEX NUT AND STRUCTURAL WASHER WSW HOLDOWN SEE 10/WSW2 FOR ALLOWABLE EDGE AND FACE DRILL ZONES WSW DESIGNED TO PROVIDE 18" GAP BETWEEN LSL AT BASE OF WSW AND CONCRETE. ENSURE CONCRETE IS LEVEL AND SMOOTH BENEATH PANEL. GRIND OR FILL AS NECESSARY. REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. OR6 7 OR4 5 ALTERNATE 7 8" MAXIMUM WOOD SHIM. FOR SHIMS GREATER THAN 7 8", SEE 9/WSW2. WSW-TOW SHEAR TRANSFER PLATE ALTERNATE WSW GARAGE FRONT OPTIONS MODEL NO.W (in.) H (in.) ANCHOR BOLTS TOTAL WALL WEIGHT (lb.)QUANTITY DIA. (in.) WSW12x7 12 78 2 7/8 100 WSW18x7 18 78 2 7/8 145 WSW12x7.5 12 85 1/2 2 7/8 110 WSW18x7.5 18 85 1/2 2 7/8 155 WSW12x8 12 93 1/4 2 7/8 115 WSW18x8 18 93 1/4 2 7/8 165 WSW24x8 24 93 1/4 2 1 225 WSW12x9 12 105 1/4 2 7/8 130 WSW18x9 18 105 1/4 2 7/8 185 WSW24x9 24 105 1/4 2 1 245 WSW12x10 12 117 1/4 2 7/8 140 WSW18x10 18 117 1/4 2 7/8 205 WSW24x10 24 117 1/4 2 1 270 WSW12x11 12 129 1/4 2 7/8 150 WSW18x11 18 129 1/4 2 7/8 220 WSW24x11 24 129 1/4 2 1 295 WSW12x12 12 141 1/4 2 7/8 165 WSW18x12 18 141 1/4 2 7/8 240 WSW24x12 24 141 1/4 2 1 320 WSW18x13 18 153 1/4 2 7/8 255 WSW24x13 24 153 1/4 2 1 345 WSW24x14 24 168 2 1 375 WSW24x16 24 192 2 1 425 WSW18x20 18 240 2 7/8 385 WSW24x20 24 240 2 1 520 NOTES: 1. FOR HEIGHTS NOT LISTED, ORDER THE NEXT TALLEST PANEL AND TRIM TO FIT. MINIMUM TRIMMED HEIGHT FOR ALL PANELS IS 74½". 2. ALL PANELS COME WITH TWO PRE-ATTACHED HOLDOWNS, TWO STANDARD HEX NUTS, TWO STRUCTURAL WASHERS, TWO WSW-TOW PLATES AND INSTALLATION INSTRUCTIONS. 3. ALL PANELS ARE 3½" THICK. STRONG-WALL ®WOOD SHEARWALL MODELS SEE SHEETS WSW1 AND WSW1.1 FOR ANCHORAGE SOLUTIONS HEX NUT AND STRUCTURAL WASHER PLACE STRONG-WALL ® WOOD SHEARWALL OVER THE ANCHOR BOLTS AND SECURE WITH WASHER AND HEX NUTS (PROVIDED). SNUG TIGHT FIT REQUIRED; DO NOT USE AN IMPACT WRENCH. •USE 15 16" WRENCH FOR 7 8" NUT •USE 112" WRENCH FOR 1" NUT SEE SHEETS WSW1 AND WSW1.1 FOR ANCHORAGE SOLUTIONS STRONG-WALL ® WOOD SHEARWALL STRONG-WALL ® WOOD SHEARWALL STRONG-WALL ® WOOD SHEARWALL JOIST HANGER (IF REQUIRED) FRAMING BY OTHERS (TYPICAL) SILL PLATE ANCHORAGE BY OTHERS STRONG-WALL ®WOOD SHEARWALL HEIGHT TO INCLUDE THE DEPTH OF THE FLOOR SYSTEM AND SHALL BE INSTALLED DIRECTLY ON THE FOUNDATION. SPECIFY PANEL HEIGHT FROM TOP OF FOUNDATION TO UNDERSIDE OF TOP PLATES OR BEAM. TOP PLATES 7 8" MAXIMUM WOOD SHIM. FOR SHIMS GREATER THAN 7 8", SEE 9/WSW2. ATTACH WSW-TOW PLATES (PROVIDED) TO FRAMING AND WSW PANEL BOTH SIDES USING 10d x 212" NAILS MIN. FOR ALTERNATE CONNECTION SEE 7/WSW2. 4 OR6 7 ALTERNATE 4 REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. ROUGH OPENING HEIGHT H CURB SHEAR TRANSFER DESIGN AND DETAILS BY OTHERS POST AND CONNECTION DETAILS BY OTHERS 318" MIN. WIDTH BY 9 14" MIN. DEPTH HEADER BY OTHERS. FOR WSW AND HEADER FURRING REQUIREMENTS, WHEN APPLICABLE, SEE DETAILS 4/WSW4 AND 5/WSW4. GARAGE HEADER ROUGH OPENING HEIGHT MODEL NO. H CURB ROUGH OPENING HEIGHT WSW12x7 WSW18x7 WSW24x7 512" 6'-11 12" 6" 7'-0" WSW12x7.5 WSW18x7.5 WSW24x7.5 0"7'-112" WSW12x8 WSW18x8 WSW24x8 512" 8'-2 3 4" 6" 8'-3 14" NOTES: 1. IF REQUIRED ROUGH OPENING HEIGHT EXCEEDS TABLE VALUE, SPECIFY NEXT TALLER PANEL AND TRIM AS NECESSARY. THE STRONG-WALL ® WOOD SHEARWALL MAY BE TRIMMED TO A MINIMUM HEIGHT OF 74 12". 2. FURRING DOWN GARAGE HEADER MAY BE REQUIRED FOR CORRECT ROUGH OPENING HEIGHT. FOR GARAGE WALL OPTION 2, REGISTERED DESIGN PROFESSIONAL SHALL DESIGN AND DETAIL FOR : 1. SHEAR TRANSFER 2. OUT-OF-PLANE LOADING EFFECT 3. INCREASED OVERTURNING AND DRIFT DUE TO ADDITIONAL HEIGHT ALIGN WSW-TOW NOTCHES WITH BOTTOM OF TOP PLATES 4x FRAMING FOR 518"–512" FRAMING, ATTACH DFL, SP OR SCL WOOD FURRING BLOCK BETWEEN WSW PANEL AND WSW-TOW WITH SDS 14" x 312" SCREWS (MIN.) OR 16d COMMON NAILS (8 TOTAL FASTENERS FOR WSW12, 10 FOR WSW18 AND 14 FOR WSW24). MINIMUM BLOCK SIZE IS 1 3 4" x 117 8" x WSW PANEL WIDTH. 2" MIN. 3" MIN. 3" MIN. 2" MIN. DFL, SP OR SCL WOOD FURRING BLOCK (REQUIRED FOR 518"–512" FRAMING MEMBERS) TOP PLATES 7 8" MAXIMUM WOOD SHIM. FOR SHIMS GREATER THAN 7 8", SEE 9/WSW2. ATTACH WSW-TOW PLATE (PROVIDED) ON ONE SIDE ONLY WITH A COMBINATION OF SDS 14" x 6" AND SD #10 x 1 12" CONNECTOR SCREWS (ORDER SEPARATELY AS WSW-TOW__KT) ALIGN WSW-TOW NOTCHES WITH BOTTOM OF TOP PLATES SIMPSON STRONG-TIE ® A35 FRAMING ANCHORS DOUBLE TOP PLATES OPTIONAL 1" DIAMETER BY 14" DEEP COUNTERBORE WSW-TOW ALTERNATE CONNECTION KIT MODEL NO. FASTENER QUANTITY SD #10 x 112" SDS 14" x 6" WSW-TOW12KT 20 2 WSW-TOW18KT 28 4 WSW-TOW24KT 40 8 FURRING NOT REQUIRED FOR ALTERNATE TOP CONNECTION EXCEPT AS REQUIRED FOR FINISH MATERIAL ATTACHMENT B W L L= W(MIN.) NOTES: 1. MAINTAIN END DISTANCES TO PREVENT SCREWS FROM PENETRATING THROUGH THE OUTER EDGES. 2. INSTALL SCREWS PERPENDICULAR TO THE TOP PLATE. 3. EDGE DISTANCES ASSUME DOUBLE TOP PLATE. 2X6 OR WIDER FRAMING A INSTALLATION NOTES : 1. ACTUAL CUT LENGTH (L) MUST BE GREATER THAN OR EQUAL TO PANEL WIDTH (W). 2. THIS DETAIL APPLICABLE FOR SLOPES UP TO 12:12. 3. PANELS TALLER THAN 12' MUST BE DESIGNED FOR THE APPLICATION. EDGE DISTANCE FOR SCREWS SLOPE A (in.) B (in.) 0:12-4:12 2 3 5:12-8:12 1 1/2 4 1/2 9:12-12:12 1/2 5 1/2 (4) SIMPSON STRONG-TIE ® LTP4 OR A35 FRAMING ANGLES. MAY BE USED IN COMBINATION (2 PER SIDE). NO HOLES IN HATCHED REGION. END OF PANEL TO NEAREST SCREW (SEE TABLE) INSTALL SDS 1 4" x 6" SCREWS (ORDER SEPARATELY). INSTALL IN 2 ROWS AS SHOWN AND COUNTERSINK AS REQUIRED. SIMPSON STRONG-TIE ® LTP4 FRAMING ANCHORS STRONG-WALL ® WOOD SHEARWALL SDS SCREW SPACING 13 8" O.C. MIN.12" MIN. SDS TIP TO CHASE QTY. OF SDS1 4" x 6" SCREWS REQ'D. WSW12 4 WSW18 8 WSW24 12 12" MIN. AT EDGE 1" MIN. FROM EDGE W 114" MIN. ROW SPACING SECTION ATTACH SIMPSON STRONG-TIE ® CS16 STRAPS AT EDGE OF WSW PANEL (EACH SIDE) USING 10d x 1½" NAILS •8 NAILS INTO BLOCK •8 NAILS INTO WSW PANEL •10 NAILS INTO BLOCK •10 NAILS INTO WSW PANEL REGISTERED DESIGN PROFESSIONAL SHALL DESIGN AND DETAIL FOR : 1. SHEAR TRANSFER 2. OUT-OF-PLANE LOADING EFFECT 3. INCREASED OVERTURNING AND DRIFT DUE TO ADDITIONAL HEIGHT 41 8" TO 12" SHIM BLOCK 1" TO 4" SHIM BLOCK CRIPPLE WALL INSTALL SDS 14" x 6" SCREWS (MIN.) FROM THE TOP SIDE OF THE PLATES PER QTY. AND SPACING REQUIREMENTS DETAILED IN 8/WSW2. STRONG-WALL ® WOOD SHEARWALL FULL-HEIGHT ADJACENT FRAMING BY OTHERS LTP4 SPACING BY OTHERS 4x SHIM BLOCK FULL-HEIGHT ADJACENT FRAMING BY OTHERS SEE 6 & 7/WSW2 FOR TOP CONNECTION CRIPPLE SHEARWALL, BLOCKING AND STRAP BY OTHERS NO HOLES ALLOWED IN TOP 8" OF PANEL CENTER 45 8" OF PANEL FACE AS SHOWN ALTERNATE FRAMING BY OTHERS (NOT SHOWN FOR CLARITY) 1. STRONG-WALL WOOD SHEARWALL IS MANUFACTURED AND TRADEMARKED BY "SIMPSON STRONG-TIE COMPANY INC."HOME OFFICE: 5956 W. LAS POSITAS BLVD. , PLEASANTON, CA 94588 TEL: (800) 999-5099, FAX: (925) 847-1597. "SIMPSON STRONG-TIE COMPANY INC." IS AN ISO 9001-2008 REGISTERED COMPANY. 2. USE OF THIS PRODUCT IS SUBJECT TO THE APPROVAL OF THE LOCAL BUILDING DEPARTMENT. 3. THIS PRODUCT IS PART OF THE OVERALL LATERAL FORCE RESISTING SYSTEM OF THE STRUCTURE. DESIGN OF THE BUILDING'S LATERAL FORCE RESISTING SYSTEM, INCLUDING THE LOAD PATH TO TRANSFER LATERAL FORCES FROM THE STRUCTURE TO THE GROUND, IS THE RESPONSIBILITY OF THE DESIGNER. 4. ENGINEER OF RECORD IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. 5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ELEVATIONS, ETC. PRIOR TO INSTALLATION OF ANY COMPONENTS FOR THE STRONG-WALL SB SYSTEM. IF ANY DISCREPANCIES ARE FOUND, THEY SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER FOR CLARIFICATION PRIOR TO CONSTRUCTION. 6. INSTALLATION OF PRODUCT SHALL BE DONE IN CONFORMANCE TO THESE DRAWINGS. THE PERFORMANCE OF MODIFIED PRODUCTS OR ALTERED INSTALLATION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE DESIGNER. 7. SIMPSON STRONG-TIE COMPANY INC. RESERVES THE RIGHT TO CHANGE SPECIFICATIONS, DESIGNS, AND MODELS WITHOUT NOTICE OR LIABILITY FOR SUCH CHANGES. 8. ALL HARDWARE CALLED OUT IS SIMPSON STRONG-TIE. 9. SEE ICC-ES ESR-2652 OR CITY OF LOS ANGELES RR25730 AS APPLICABLE FOR ADDITIONAL INFORMATION. 6 1" DIAMETER BY 14" DEEP COUNTERBORE STRONG-WALL ® WOOD SHEARWALL 6x FRAMING INSTALL SDS 14" x 6" SCREWS AT AN ANGLE THAT PREVENTS THEM FROM EXITING SIDE OF FRAMING; APPROX. 30 DEGREES (TYP.) INSTALL WSW-TOW ON EXTERIOR FACE REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. FACE AND EDGE DRILL ZONES IN ADDITION TO ALLOWABLE SMALL HOLES STRONG-WALL ® WOOD SHEARWALL STRONG-WALL ® WOOD SHEARWALL SDS14" x 312" SD #10 x 112" 4x SHIM BLOCK STRONG-WALL ® WOOD SHEARWALL SEE 6 & 7/WSW2 FOR TOP CONNECTION OR6 7 WHEN WSW-PS STRAPS OMITTED, ALLOWABLE SHEAR VALUES FOR STANDARD PANEL APPLY. NAILING BY OTHERS FRAMING BY OTHERS 94 75 1 2 3 8 STANDARD INSTALLATION BASE CONNECTION STANDARD TOP CONNECTION TOP OF WALL HEIGHT ADJUSTMENTS TRIM ZONE AND ALLOWABLE HOLESALTERNATE TOP CONNECTIONWOOD FLOOR SYSTEM BASE CONNECTIONSINGLE STORY WSW ON CONCRETE RAKE WALL NOTES STRONG-WALL ® WSW MODELS 10 11 HOLES FOR •MAX. OF ONE 4 5 8" x 6" HOLE •8" FROM TOP OF PANEL, MIN. NO EDGE HOLES ALLOWED IN LOWER 26" OF PANEL NO FACE HOLES ALLOWED IN LOWER 40" OF PANEL •MAX. THREE HOLES IN FACE AND THREE IN EDGE. •3 4"-DIAMETER HOLES, MAX. •6" O.C., MIN. MAINTAIN 112" MIN. EDGE DISTANCE FROM CHASE AND OUTSIDE EDGE, TYPICAL. NO HOLES ALLOWED IN TOP 8" OF PANEL MIDDLE 13 OF PANEL THICKNESS 2418" 16" 12" ABOVE EXISTING HOLE, MIN. 4" MIN. CLEARANCE REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. PLACE STRONG-WALL ® WOOD SHEARWALL OVER THE ANCHOR BOLTS AND SECURE WITH WASHER AND HEX NUTS (PROVIDED). SNUG TIGHT FIT REQUIRED; DO NOT USE AN IMPACT WRENCH. •USE 15 16" WRENCH FOR 7 8" NUT •USE 112" WRENCH FOR 1" NUT REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. STRONG-WALL ® WOOD SHEARWALL 4x FRAMING 6x FRAMING REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. •45 8"-DIA. HOLES, MAX. •MAX. OF TWO 4 5 8"-DIA. HOLES OR ONE 414" x 12" HOLE. •NO MINIMUM ON-CENTER SPACING REQUIRED.