Loading...
HomeMy WebLinkAboutBYU-I MC and Kimball head relocateWA WA SM SM SM SM EXIT EXIT EX I T C C MIC SM EXIT C WA SM SM HS WA SM C SM SM SM SM SM SM C OFFICE 170A OFFICE 170B BREAK ROOM 170C UPS/STORAGE 170G CONFERENCE ROOM 170D CONFERENCE ROOM 170E OFFICE 170H OFFICE 170G CONFERENCE ROOM 170F CUBICLE STATIONS 170XX 2 3 2 8 6 5 9 11 8 8 8 8 8 8 5 2 6 3 5 6 4 5 10 5 5 5 5 5 5 5 8 3 5 5 3 8 3 3 10 5 5 2 3 LOBBY 1-F 4 4 4 4 44 4 4 4 4 4 4 4 4 4 4 4 4 4 4 HALLWAY 1-K VESTIBULE 1-H MECHANICAL ROOM 160OPERATIONS ROOM 171 4 4 44 4 4 44444 4 4 4 4 444 4 444 4 4 4 4 4 4 4 4 4 4 4 4444444 4 4 4 4 4444 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 444 4 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 55 5 5 2 5 8 83 3 2 92 2 2 2 5 11 11 11 8 7 7 7 5 5 6 5 1 1 1 HALLWAY 1-R CUBICLES 170L-170Y CUBICLES 170Z-170WW 5 11 5 11 7 77 7 11 2 5 5 5 7 7 2 35 2 11 3 9 WA5 7 7 7 7 7 5 7 7 8 9 OFFICE SUITE 170 4 4 5 4 4 4 4 5 5 10 11 12 PROJECT NAME: SHEET NAME: SHEET NUMBER: DESIGNED BY: DRAWN BY: REVISION SCHEDULE PROJECT NO: DOCUMENT STATUS STATUS DATE ©2022 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO, 83460 BID DOCUMENTS ARCHITECTURAL BYU-I ARCHITECTURE SERVICES 470 SOUTH PHYSICAL PLANT WAY REXBURG, IDAHO 83460 (208) 496-2500 (208) 390-2476 cell www.byui.edu tolmanda@byui.edu MECHANICAL ENGINEERED SYSTEMS ASSOCIATES 1355 EAST CENTER POCATELLO, IDAHO 83204 (208) 233-0501 phone (208) 233-0529 fax, (208) 221-9502 cell www.engsystems.com dcs@engsystems.com HVAC ENGINEERED SYSTEMS ASSOCIATES 1355 EAST CENTER POCATELLO, IDAHO 83204 (208) 233-0501 phone (208) 233-0529 fax, (208) 221-9502 cell www.engsystems.com dcs@engsystems.com ELECTRICAL PAYNE ENGINEERING INC. 1823 EAST CENTER ST. POCATELLO, IDAHO 83204 (208) 232-4439 phone (208) 232-1435 fax, (208) 251-4439 cell www.payneengineeringinc.com payneengineering@gmail.com BR I G H A M Y O U N G UN I V E R S I T Y - ID A H O bar20058@byui.edu 480-496-2666 8/22/2022 DE M O L I T I O N RE F L E C T E D CE I L I N G P L A N - KI M B A L L 1 7 0 CHAD ALLDREDGE alldredgec@byui.edu 208-496-2659 AD102 ELLA BARR 12364 KI M B A L L 1 7 0 , 2 4 4 & 2 5 0 IN F O R M A T I O N TE C H N O L O G Y O F F I C E RE M O D E L SYMBOL LEGEND 2X2 RECESSED LED LIGHT 2X2 RETURN AIR GRILLE 2X2 SUPPLY AIR GRILLE FIRE SPRINKLER CEILING MOUNTED MICROPHONE SMOKE DETECTOR EXIT SIGN CAMERA WIRELESS ARRAY STRUCTURAL COLUMN DIFFUSER ROOM OCCUPANCY SENSORN 1/4" = 1'-0"1 DEMOLITION REFLECTED CEILING PLAN - KIMBALL 170 GENERAL NOTES FIELD VERIFY EXISTING CONDITIONS INCLUDING BUT NOT LIMITED TO DIMENSIONS, QUANTITIES, AND MATERIALS ALL CONSTRUCTION IS EXISTING TO REMAIN UNLESS SPECIFICALLY NOTED OTHERWISE. ALL EXISTING TO REMAIN ITEMS THAT ARE DAMAGED BY DEMOLITION AND/OR CONSTRUCTION ACTIVITIES SHALL BE REPAIRED OR REPLACED TO THE OWNER'S SATISFACTION ALL REMOVED DOORS MUST HAVE HARDWARE SALVAGED AND RETURNED TO OWNER REMOVE ALL SWITCHINGS, THERMOSTATS AND OUTLETS LOCATED ON THE WALLS THAT WILL BE DEMOLISHED. COORDINATE WITH ELECTRICAL AND MECHANICAL DEMOLITION PLANS LEGALLY DISPOSE OF ALL DEMOLITION MATERIALS OFF SITE COORDINATE ALL ELECTRICAL, MECHANICAL, TELECOMMUNICATIONS, FIRE ALARM, AND FIRE SUPPRESION ITEMS WITH THE APPROPRIATE MECHANICAL AND ELECTRICAL SHEETS ALL DIMENSIONS ARE FROM FACE OF FRAMING UNLESS NOTED OTHERWISE I. II. III. IV. V. VI. VII. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. DEMOLISH SUPPLY AIR GRILL -DISPOSE OF LEGALLY OFF SITE -SEE MECHANICAL REMOVE SUPPLY AIR GRILL - SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION -SEE MECHANICAL REMOVE RETURN AIR GRILL -SALVAGE, PRESERVCE, AND PROTECT FOR REINSTALLATION -SEE MECHANICAL REMOVE N-LIGHT ENABLED 2X2 LED LAY-IN GRID LIGHT FIXTURE -SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION -SEE ELECTRICAL REMOVE SPRINKLER HEAD FOR REPLACEMENT WITH NEW RECESSED CONSEALED HEAD ON 4'-0" WHIP -MODIFY EXISTING FIRE SPINKLER PIPING AND HEADS AS REQUIRED FOR REMODEL WORK -SEE MECHANICAL REMOVE SECURITY CAMERA -SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION DEMOLISH LAY-IN ACOUSTIC CEILING TILE AND GRID SYSTEM -DISPOSE OF LEGALLY OFF SITE- SALVAGE, PESERVE AND PROTECT ALL WHOLE, UNDAMAGED CEILING TILES -RETURN TO OWNER REMOVE SMOKE DETECTOR -SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION -SEE ELECTRICAL REMOVE WIRELESS ARRAY -SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION REMOVE EXIT SIGN -SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION -SEE ELECTRICAL REMOVE ROOM OCCUPANCY SENSOR - SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION -SEE ELECTRICAL EXISTING HORN STROBE -REMOVE, AND REINSTALL AFTER DEMOLITION #REFERENCE NOTES ACOUSTIC CEILING TILE AND GRID SYSTEM NO. DESCRIPTION DATE SM EXIT C WA SM SMC EXIT SM EXIT OFFICE 250FOFFICE 250E OFFICE 250D OFFICE 250C OFFICE SUITE 244 OFFICE 244A OFFICE 244B OFFICE 250B OFFICE 250A OFFICE SUITE 250 4 4 4 4 4 4 OFFICE 240H OFFICE 240G RECEPTION 240 MEETING ROOM 240J 4 44 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 44 4 4 4 4 4 4 4 4 4 4 5 5 55 5 5 55 5 3 4 4 4 4 4 2 8 5 6 2 2 2 3 2 10 7 77 7 10 22 5 11 2 5 3 85 5 5 3 5 3 2 5 2 11 5 31 2 5 1 1 HALLWAY 2-L CLASSROOM 245 MECHANICAL ROOM 260 CONFERENCE/WORK ROOM 243 2 EDGE OF CEILING DEMOLITION 711 14 11 4 44 9 4 4 13 12HS 13 13 13 13 4 4 4 4 4 4 44 5 11 4 44 4 4 11 5 11 11 11SM8 8 4 4 WA PROJECT NAME: SHEET NAME: SHEET NUMBER: DESIGNED BY: DRAWN BY: REVISION SCHEDULE PROJECT NO: DOCUMENT STATUS STATUS DATE ©2022 BYU-IDAHO 525 SOUTH CENTER STREET REXBURG, IDAHO, 83460 BID DOCUMENTS ARCHITECTURAL BYU-I ARCHITECTURE SERVICES 470 SOUTH PHYSICAL PLANT WAY REXBURG, IDAHO 83460 (208) 496-2500 (208) 390-2476 cell www.byui.edu tolmanda@byui.edu MECHANICAL ENGINEERED SYSTEMS ASSOCIATES 1355 EAST CENTER POCATELLO, IDAHO 83204 (208) 233-0501 phone (208) 233-0529 fax, (208) 221-9502 cell www.engsystems.com dcs@engsystems.com HVAC ENGINEERED SYSTEMS ASSOCIATES 1355 EAST CENTER POCATELLO, IDAHO 83204 (208) 233-0501 phone (208) 233-0529 fax, (208) 221-9502 cell www.engsystems.com dcs@engsystems.com ELECTRICAL PAYNE ENGINEERING INC. 1823 EAST CENTER ST. POCATELLO, IDAHO 83204 (208) 232-4439 phone (208) 232-1435 fax, (208) 251-4439 cell www.payneengineeringinc.com payneengineering@gmail.com BR I G H A M Y O U N G UN I V E R S I T Y - ID A H O bar20058@byui.edu 480-496-2666 8/22/2022 DE M O L I T I O N RE F L E C T E D CE I L I N G P L A N - KI M B A L L 2 4 4 & 25 0 CHAD ALLDREDGE alldredgec@byui.edu 208-496-2659 AD104 ELLA BARR 12364 KI M B A L L 1 7 0 , 2 4 4 & 2 5 0 IN F O R M A T I O N TE C H N O L O G Y O F F I C E RE M O D E L 1/4" = 1'-0"1 DEMOLITION REFLECTED CEILING PLAN - KIMBALL 244 & 250 N SYMBOL LEGEND 2X2 RECESSED LED LIGHT 2X2 RETURN AIR GRILLE 2X2 SUPPLY AIR GRILLE FIRE SPRINKLER GENERAL NOTES SMOKE DETECTOR EXIT SIGN CAMERA WIRELESS ARRAY DIFFUSER ROOM OCCUPANCY CENTER 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. #REFERENCE NOTES FIELD VERIFY EXISTING CONDITIONS INCLUDING BUT NOT LIMITED TO DIMENSIONS, QUANTITIES, AND MATERIALS ALL CONSTRUCTION IS EXISTING TO REMAIN UNLESS SPECIFICALLY NOTED OTHERWISE. ALL EXISTING TO REMAIN ITEMS THAT ARE DAMAGED BY DEMOLITION AND/OR CONSTRUCTION ACTIVITIES SHALL BE REPAIRED OR REPLACED TO THE OWNER'S SATISFACTION ALL REMOVED DOORS MUST HAVE HARDWARE SALVAGED AND RETURNED TO OWNER REMOVE ALL SWITCHINGS, THERMOSTATS AND OUTLETS LOCATED ON THE WALLS THAT WILL BE DEMOLISHED. COORDINATE WITH ELECTRICAL AND MECHANICAL DEMOLITION PLANS LEGALLY DISPOSE OF ALL DEMOLITION MATERIALS OFF SITE COORDINATE ALL ELECTRICAL, MECHANICAL, TELECOMMUNICATIONS, FIRE ALARM, AND FIRE SUPPRESION ITEMS WITH THE APPROPRIATE MECHANICAL AND ELECTRICAL SHEETS ALL DIMENSIONS ARE FROM FACE OF FRAMING UNLESS NOTED OTHERWISE I. II. III. IV. V. VI. VII. ACOUSTIC CEILING TILE AND GRID SYSTEM DEMOLISH GYPSUM BOARD ON STEEL STUD WALL -DISPOSE OF LEGALLY OFF SITE REMOVE SUPPLY AIR GRILL - SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION -SEE MECHANICAL REMOVE RETURN AIR GRILL -SALVAGE, PRESERVCE, AND PROTECT FOR REINSTALLATION -SEE MECHANICAL REMOVE N-LIGHT ENABLED 2X2 LED LAY-IN GRID LIGHT FIXTURE -SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION -SEE ELECTRICAL REMOVE SPRINKLER HEAD FOR REPLACEMENT WITH NEW RECESSED CONSEALED HEAD - MODIFY EXISTING FIRE SPINKLER PIPING AND HEADS AS REQUIRED FOR REMODEL WORK - SEE MECHANICAL REMOVE SECURITY CAMERA -SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION DEMOLISH LAY-IN ACOUSTIC CEILING TILE AND GRID SYSTEM -DISPOSE OF LEGALLY OFF SITE- SALVAGE, PESERVE AND PROTECT ALL WHOLE, UNDAMAGED CEILING TILES TO RETURN TO OWNER REMOVE SMOKE DETECTOR -SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION REMOVE WIRELESS ARRAY -SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION REMOVE EXIT SIGN -SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION REMOVE ROOM OCCUPANCY SENSOR - SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION REMOVE HORN STROBE -SALVAGE, PRESERVE, AND PROTECT FOR REINSTALLATION -SEE ELECTRICAL DEMOLISH DUPLEX ELECTRICAL OUTLET BACK TO NEAREST JUNCTION -RETAIN CONNECTIVITY TO UP AND DOWN SYSTEM DEVICES -SEE ELECTRICAL DEMOLISH DATA BACK TO NEAREST JUNCTION - MAINTAIN CONNECTIVITY TO UP AND DOWN SYSTEM DEVICES -SEE ELECTRICAL EDGE OF CEILING DEMOLITION NO. DESCRIPTION DATE