HomeMy WebLinkAboutMETAL BUILDING-FOR PERMIT-22.09.21 (1)-Reviewed-Corrections-RequiredAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Description : 9770 Rustlers Trl - Shop Address : 9770 Rustlers Trl Application Type : Document Filename : METAL BUILDING-FOR PERMIT-22.09.21 (1).pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments GN001 Free text Cody Jones : Building Open 2 36" GN001 Free text Cody Jones : Building Open 2 Roof snow load 35 Ground snow load 50 GN001 Free text Cody Jones : Building Open 2 Need architectural drawings and design criteria plans showing: Use classification. Type of construction Occupant load Exits, Travel distance Sprinkled? (Please contact Stan C. with Fire Department) Site plan Special Inspector needs to be identified Etc... # 22-00722 Madison County - Commercial Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 10.03.2022 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 A B C D E F G H I J K L A B C D E F G H I J K L TH E S E P L A N S , D R A W I N G S A N D D E S I G N S A R E T H E E X C L U S I V E P R O P E R T Y O F D O M E T E C H N O L O G Y . A N D S H A L L N O T B E R E P R OD U C E D I N A N Y F O R M W I T H OU T W R I T T E N C O N S E N T . A L L R I G H T S A R E R E S E R V E D . C O P YR I G H T 2 0 1 9 D O M E T E C H N O L O G Y . 4946 North 2900 East, Idaho Falls, ID 83401 tel: (208) 529-0833 fax: (208) 529-0854 DOME TECHNOLOGY 14 REVISION DESCRIPTION REV. SHEET TITLE: REF NUMBER DESIGNED DRAWN CHECKED APPROVED SEAL START DATE: PROJECT NUMBER: SCALE: SHEET NIMBER: PR I N T E D : PROJECT: LOCATION: SITE LOCATION MAP CONTACT INFORMATION OWNER: LOCATION: PROJECT: DRAWING INDEX GENERAL NOTES CODE INFORMATION 9750PROFESSIONALE N GIN E E R I D A HO OF S T ATE REGISTER ED J ASON S O U T H STRUCTURAL ENGINEER: C:\Users\samuel.zapata\Desktop\STEEL BUILDING CONCRETE SLAB.rvt 0 1" = 1'-0" 9/ 2 1 / 2 0 2 2 4 : 4 8 : 1 6 P M METAL BUILDING FOUNDATION FOR AARON SHEPPARD MENAN, ID COVER SHEET JS SZ JS JS GN000 70XX 70XX -GN000 -REV 0 -22.09.21 METAL BUILDING FOUNDATION FOR AARON SHEPPARD MENAN, ID NUMBER DESCRIPTION REVISION DATE SC101 FOUNDATION PLAN 0 22.09.21 SC501 FOUNDATION DETAILS 0 22.09.21 GN001 GENERAL STRUCTURAL NOTES 0 22.09.21 GN000 COVER SHEET 0 22.09.21 SC502 TYPICAL DETAILS 0 22.09.21 DOME TECHNOLOGY 4946 North 29th East Idaho Falls, ID 83401 United States of America +1 (208) 529 0833 AARON SHEPPARD MENAN, IDAHO 1. THE CONTRACT DOCUMENTS FOR THIS PROJECT CONSIST OF DRAWINGS PREPARED BY DOME TECHNOLOGY 2. ALL WORK SHALL COMPLY WITH THE APPLICABLE LOCAL CODES, AND ALL MUNICIPAL AMENDMENTS. 3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE WORK SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION. 4. ALL WORK SHALL CONFORM TO ALL INDUSTRY AND MANUFACTURER'S PUBLISHED STANDARDS AND THE BUILDING OWNER'S REQUIREMENTS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS ALL REQUIREMENTS IN THESE DRAWINGS AND SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE TO BECOME FAMILIAR AND COMPLY WITH THE BUILDING OWNER'S STANDARD DETAILS OF CONSTRUCTION. ANY CONFLICTING REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO THE METAL BUILDING FABRICATOR ATTENTION PRIOR TO PROCEEDING WITH WORK. 5. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL BASE BUILDING "CONTRACT DOCUMENTS", "SHOP DRAWINGS", "AS BUILT DRAWINGS", AND ANY OTHER INFORMATION OF THE BASE BUILDING IN ORDER TO COORDINATE ALL TENANT WORK WITH THE BASE BUILDING IN ORDER TO COORDINATE ALL TENANT WORK WITH THE BASE BUILDING CONDITIONS. 6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS, BONDS, AND FEES. ALL NECESSARY PERMITS, LICENSES, TESTS, CERTIFICATES, ETC. SHALL BE PAID FOR BY THE CONTRACTOR AND REIMBURSED BY THE OWNER. 7. NO SUBSTITUTIONS FOR ITEMS SPECIFIED WILL BE ACCEPTED WITHOUT PRIOR WRITTEN APPROVAL FROM THE ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR SUPPLYING THE ENGINEER OF RECORD WITH ALL SAMPLES AND COMPARATIVE PRODUCT DATA REQUIRED TO EVALUATE PROPOSED SUBSTITUTIONS, IN A TIMELY MANNER SO AS NOT TO PRECLUDE PROCUREMENT OF THE PRODUCT ORIGINALLY SPECIFIED OR ANY PROPOSED SUBSTITUTE. 8. THE GENERAL CONTRACTOR SHALL PROTECT EXISTING CONDITIONS OR WORK BY OTHER CONTRACTORS. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO ALL EXISTING CONDITIONS OR WORK BY OTHERS INCURRED WHILE FULFILLING THE OBLIGATIONS OF THIS CONTRACT. 9. ALL WORK NOTED "BY OTHERS" OR "N.I.C." (NOT IN CONTRACT) IS TO BE THE RESPONSIBILITY OF THE OWNER AND IS NOT TO BE PART OF THE CONSTRUCTION AGREEMENT. THE GENERAL CONTRACTOR SHALL COOPERATE WITH THE OWNER AND THE OWNER'S OUTSIDE CONTRACTORS AS REQUIRED. 10. THE GENERAL CONTRACTOR SHALL COORDINATE THE REMOVAL AND LEGAL DISPOSAL OF MATERIALS AND RUBBISH WITH THE BUILDING MANAGEMENT. 11. THE GENERAL CONTRACTOR SHALL PROTECT AND SECURE THE PROJECT SITE AS REQUIRED, IN CONFORMANCE WITH ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES AND REGULATIONS. 12. ALL WORK SHALL BE OF FIRST CLASS WORKMANSHIP AND GUARANTEED BY THE CONTRACTOR AGAINST DEFECTS AND POOR WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM SUBSTANTIAL COMPLETION. 13. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR BLOCKING AND ELECTRICAL CONNECTIONS. PROVIDE ADEQUATE CONCEALED BLOCKING AND BRACING FOR ALL MILLWORK HUNG FROM CEILING AND /OR PARTITIONS; FIRE TREATED WOOD OR SHEET METAL IS ACCEPTABLE. ALL WOODWORK, BLOCKING, GROUNDS, ETC. SHALL BE FIRE TREATED IN ACCORDANCE WITH ALL APPLICABLE CODES. 14. THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE BEFORE FABRICATING ANY MATERIAL AND REPORT ANY DISCREPANCIES TO THE ENGINEER OF RECORD. 15. PATCH AND REPAIR SHALL FIREPROOFING, IF ANY, DAMAGED OR REMOVED BY TENANT CONSTRUCTION. 16. ALL OPENINGS IN WALLS AND SLABS, INCLUDING THOSE FOR DUCTS, CONDUIT, PIPING, ETC. (EXCEPT WHEN COMPLETELY ENCLOSED BY FIRE-RESISTIVE SHAFT CONSTRUCTION) MUST BE SLEEVED OR OTHERWISE SEALED AT THEIR PERIMETER WITH APPROVED METHODS TO MAINTAIN THE FIRE-RATING CONTINUITY OF THE CONSTRUCTION. 17. WALL AND/OR CEILING ASSEMBLIES THAT ARE IDENTIFIED WITH A FIRE RESISTIVE RATING SHALL BE CONSTRUCTED PER MANUFACTURER'S SPECIFICATIONS AND THE REQUIREMENTS OF ALL APPLICABLE CURRENT CODES AND GOVERNING BODIES. 18. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED FROM EACH OTHER TO AVOID MOLECULAR BREAKDOWN. 19. DO NOT SCALE DRAWINGS UNLESS NOTED OTHERWISE; DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. ALL LOCATIONS ARE FINAL PER METAL BUILDING FABRICATOR DRAWINGS. 20. JUNCTURES OF NEW AND EXISTING OR OTHER WORK SHALL BE REPAIRED AND PATCHED TO MATCH ADJACENT EXISTING SURFACES. EXISTING WALLS REQUIRING MODIFICATIONS OF ANY KIND SHALL BE REFINISHED TO THE NEAREST OUTSIDE OR INSIDE CORNER. 21. CONTRACTOR SHALL REVIEW AND APPROVE ALL SHOP DRAWINGS AND EQUIPMENT CUTS PRIOR TO SUBMITTAL TO ENGINEER OF RECORD. CONTRACTOR SHALL SUBMIT ALL APPROVED SHOP DRAWINGS AND EQUIPMENT CUTS TO ENGINEER OF RECORD. FOR REVIEW PRIOR TO FABRICATION. 22. DEVIATION FROM THE DESIGN OF TESTED RATED ASSEMBLY'S SHALL NOT BE ALLOWED. REV. REVISION NOTE DATE YY.MM.DD DT 1 A ISSUED FOR PERMIT 22.09.21 2018 IBC WITH IDAHO AMMANDEMENTS REV REVISION NOTE DATE YY.MM.DD DT 0 ISSUED FOR PERMIT 22.09.21 DATE 22.09.21 GE ERA STRUCTURA TES GE ERA REQUIRE E TS F U DATI DOME TECHNOLOGY RECOMMENDS THAT A GEOTECHNICAL REPORT BE COMPLETE PRIOR TO CONSTRUCTION. IN THE EVENT THAT A GEOTECHNICAL REPORT IS NOT PROVIDED, DOME TECHNOLOGY ASSUMES NO LIABILITY FOR THE ENGINEERING EXPERTISE NORMALLY PROVIDED BY A REPUTABLE GEOTECHNICAL ENGINEER. DOME TECHNOLOGY ASSUMES NO LIABILITY FOR GROUNDWATER OR OTHER MEANS OF FLOODING. GE TECH ICA REP RT REI F RCI G STEE (C T) ALL BARS SHALL BE DETAILED AND PLACED PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERT REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. P ACE A D DETAI GOVERNING BUILDING CODE.................................................................................................................2018 IBC OCCUPANCY CATEGORY.....................................................................................................................................II DESIG ADS BASIS F R DESIG DESIG ADS ROOF DEAD.....................................................................................SELF WIGHT + 180 PSF (OVER BORDEN) LIVE................................................................................................................................................30 PSF SNOW.............................................................................................................................................28 PSF IS (SNOW LOAD IMPORTANCE FACTOR)...........................................................................................1.0 DRIFTING PER IBC CHAPTER 16 DEF ECTI I ITS ROOF ELEMENTS TOTAL LOAD......................................................................................................................................L/240 LIVE LOAD..........................................................................................................................................L/360 FLOOR ELEMENTS TOTAL LOAD......................................................................................................................................L/240 LIVE LOAD..........................................................................................................................................L/360 WALL GIRT DEFLECTION...............................................................................................................................L/120 WI D ADS (STRE GTH ADS) WIND DESIGN CODE.............................................................................................................................ASCE 7-16 BASIC WIND SPEED..................................................................................................................................115 MPH WIND IMPORTANCE FACTOR (lw).....................................................................................................................1.0 WIND EXPOSURE CLASS.....................................................................................................................................C INTERNAL PRESSURE COEFFICIENT (GCpi)...............................................................................................±0.18 SEIS IC ADS SEISMIC IMPORTANCE FACTOR (le)................................................................................................................1.0 SEISMIC DESIGN CATEGORY..............................................................................................................................D SRFS.............................................................................ORDINARY REINFORCED CONCRETE SHEAR WALLS RESPONSE MODIFICATION FACTOR (R).........................................................................................................4.0 ANALYSIS PROCEDURE....................................................................................EQUIVALENT LATERAL FORCE MAPPED SPECTRAL RESPONSE COEFFICIENTS SS.......................................................................................................................................................0.330g S1.......................................................................................................................................................0.130g SPECTRAL RESPONSE COEFFICIENTS SSD.....................................................................................................................................................0.338g SD1......................................................................................................................................................0.207g S I S SOIL BEARING PRESSURE.....................................................................................................................2500 PSF MINIMUM EMBEDMENT DEPTH...........................................................................................................30 INCHES AS A MINIMUM THE EXISTING SUB-BASE SHALL BE FREE OF COBBLES LARGER THAN 12" IN DIAMETER AND SILT OR CLAY DEPOSITS. EXISTING SUB-BASE SHALL BE SCARIFIED FOR 12" DEPTH AND COMPACTED (95% DRY DENSITY), AND 8" OF WELL-GRADED 3" MINUS GRANULAR MATERIAL BE PLACED ON EXISTING COMPACTED SUB-BASE AND COMPACTED (95% DRY DENSITY). F U DATI PREPARATI INTERIOR FOOTINGS: TOP OF SLAB PERIMETER FOOTINGS: PAD GRADE OR NATURAL GRADE BEFORE LANDSCAPING. EXTERIOR FOOTINGS: TOP OF PERMANENT EXTERIOR PAVING OR CONCRETE AT LEAST 5 FEET WIDE STARTING AT THE BUILDING PERIMETER. GRADE IS DEFI ED AS F WS SUPPORT BY 6" OF 3" MINUS MATERIAL COMPACTED TO 95% DRY DENSITY FOLLOW ACI 302.1 RECOMMENDATIONS FOR PLACING CONCRETE, CURING, AND QUALITY CONTROL. S AB GRADE BACKFILL SHALL NOT BE PLACED AGAINST EXTERIOR WALLS UNTIL THE INTERIOR FLOOR SYSTEM CAN ADEQUATELY BRACE THE WALL. BACKFILL AND RECOMPACT ALL TRENCHES. (MIN 90% DRY DENSITY) BAC FI PROVIDE ADEQUATE DRAINAGE AWAY FROM THE STRUCTURE. DRAI AGE REI F RCI G STEE ALL REINFORCING BARS SHALL BE DEFORMED BARS, EXCEPT AS NOTED IN ACI 301. GRADE TYPE ALL WELDED BARS #4 OR LARGER #3 OR SMALLER WELDED WIRE FABRIC GRADE 60 60 40 60 AST STD A706 A615 A615 A185 ALL DIMENSIONS NOT NOTED AS "CLR" ARE TO THE CENTER OF THE BAR. MIN COVER FOR NON-PRESTRESSED STEEL (U.N.O.) C EAR C VER STRUCTURA E E E T FOOTINGS AND SLAB ON GRADE WALLS (#5 OR SMALLER) WALLS (#6 OR LARGER) ELEVATED SLABS, BEAMS AND COLUMNS C VER 3" 1 1/2" 2" 1 1/2" T ERA CE 3/8" 3/8" 1/2" 3/8" LENGTHS SHALL BE PROVIDED PER THE FOLLOWING TABLE. (U.N.O TACK WELDING OF REINFORCING BARS NOT ALLOWED.) SPLICES MAY BE CONTACT OR NON CONTACT. AP SP ICES BAR #3 #4 #5 #6 #7 #8 #9 #10 #11 (a) AP 18" 18" 23" 28" 36" 47" 59" 75" 92" T ERA CE 31" 31" 39" 48" 62" 80" 101" 128" 157" REBAR AP SCHEDU E (a.) WHERE SPLICES ARE STAGGERED AT LEAST ONE LAP LENGTH USE THERE LAP LENGTHS (b.) WHERE MORE THAN 1/3 OF BARS ARE SPLICED AT ONE LOCATION USE THERE LAP LENGTHS DBA's BAR SI E #3 #4 #5 #6 #7 #8 WE D SI E 1/4" 5/16" 3/8" 7/16" 1/2" 9/16" DBA WE D SCHEDU E 1. ALL DBA'S SHALL BE A706 60 GRADE 2. ALL WELDING SHALL BE PERFORMED W/ E70 ELECTRODE TES DBA FILLET WELD ALL REINFORCING AND DBA'S (DEFORMED BAR ANCHORS) TO BE WELDED SHALL BE A706. WELDING OF REINFORCING BARS, METAL INSERTS, AND CONNECTIONS SHALL CONFORM WITH AWS D1.4, AND SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. WE DI G BENDING SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. ALL REINFORCING SHALL BE BENT COLD. BARS SHALL NOT BE UN-BENT AND RE-BENT. #6 BAR AND SMALLER MAY BE COLD FIELD BENT. #7 BAR AND LARGER SHALL NOT BE FIELD BENT WITH OUT PRIOR APPROVAL FROM ENGINEER OF RECORD. BE DI G MECHANICAL SPLICE COUPLERS SHALL HAVE CURRENT ICC-ES OR IAP MD-ES APPROVAL AND SHALL BE CAPABLE OF DEVELOPING 125% OF THE STRENGTH OF THE BAR. ECHA ICA C UP ERS REINFORCEMENT SUPPORTS SHALL BE PROVIDED TO MAINTAIN "CLR" DISTANCES SHOWN ON PLANS, AND SHALL CONFORM TO ACI 301. REI F RCE E T SUPP RTS EP XY A CH RAGE EPOXY GROUTED DOWELS SHALL BE INSTALLED USING: SIMPSON STRONG-TIE SET XP ADHESIVE ANCHOR SYSTEM HILTI HIT-RE 500 ADHESIVE ANCHOR SYSTEM INSTALL THE ABOVE SYSTEMS PER THE ICC REPORT AND MFR'S RECOMMENDATIONS. ALTERNATE EPOXY GROUT SYSTEMS WITH CURRENT ICC-ES OR IAP MD-ES APPROVAL MAY BE SUBMITTED BY THE CONTRACTOR FOR APPROVAL. D WE S C CRETE SHALL BE AS FOLLOWS: MINIMUM 28 DAY COMPRESSIVE STRENGTH SHOTCRETE................................................................................................................................ 4000 PSI CAST-IN-PLACE & PRECAST CONCRETE................................................................................ 4000 PSI LEAN FILL..................................................................................................................................... 1500 PSI PROPORTIONING CEMENT TYPE......................................................................................................................................... II MAX W/C RATIO.................................................................................................................................. 0.45 AIR ENTRAINMENT MEASURED PRIOR TO PUMPING.........................................N/A (INSIDE DOME) 6% ± 1.5% (OUTSIDE DOME) COARSE AGGREGATE SHOTCRETE................................................................................................................................3/8" MAX SLAB ON GRADE......................................................................................................................1 1/2" MAX SHOTCRETE................................................................................................................................3/4" MAX ALL CONCRETE SHALL BE NORMAL WEIGHT USING HARD ROCK AGGREGATES CONFORMING TO ASTM C33. ATERIA BATCHING, MIXING, AND TRANSPORTING CONCRETE SHALL BE PER ACI 301. CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE ENGINEER OF RECORD. PORTLAND CEMENT SHALL CONFORM TO ACI 301. WATER SHALL NOT BE ADDED AT THE JOB SITE SUCH THAT THE APPROVED MIX DESIGN W/C RATIO IS EXCEEDED. BATCHI G! IXI G! A D TRA SP RTI G FORM WORK SHALL BE PER ACI 301 F R W R PLACING OF CONCRETE SHALL BE PER ACI 301. PLACING OF CONCRETE BY MEANS OF PUMPING SHALL BE PER ACI 301. WHERE THERE IS A RISK OF PREMATURE DRYING SUCH AS IN HOT OR WINDY WEATHER CURING MEASURES SHALL BE IMPLEMENTED PER THE RECOMMENDATIONS OF ACI 301. P ACI G CONSOLIDATION OF CONCRETE SHALL BE PER ACI 301 C S IDATI EMBEDDED ITEMS SHALL BE PLACED PER ACI 301. CONDUITS AND PIPES SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OF RECORD. EMBEDDED CONDUITS, PIPES, AND SLEEVES SHALL NOT BE LARGER IN DIAMETER THAN 1/3 THE OVERALL THICKNESS OF THE SLAB, BEAM, OR WALL IN WHICH THEY ARE EMBEDDED AND SHALL NOT BE SPACED CLOSER THAN 3 DIAMETERS OR ELEMENT WIDTHS ON CENTER. NO ALUMINUM EMBEDS SHALL BE IN DIRECT CONTACT WITH CONCRETE. E BEDDED ITE S WHEN THE AIR TEMPERATURE IS BELOW 40° F COLD WEATHER CONCRETE PROCEDURES SHALL BE USED, PER 301. A CONSTRUCTION PLAN SHALL BE SUBMITTED TO THE ENGINEER DETAILING THE PROTECTION PROCEDURES PRIOR TO PLACEMENT OF CONCRETE. C D WEATHER C CRETI G CONTRACTOR SHALL FOLLOW ACI 301 AGGREGATE SPECIFICATION INCLUDING #8 AND #4 AGGREGATES TO PROVIDE A WELL GRADED AGGREGATE MIX. CONTRACTOR SHALL PROVIDE CONTROL JOINTS AT 2 TO 3 TIME THE SLAB THICKNESS IN FEET O.C. EACH WAY (IE) 4" SLAB=8' TO 12' JOINT SPACING S AB GRADE DEFERRED SUB ITTA S ALL ITEMS CONSIDERED IN THESE DESIGN DOCUMENTS AS BY OTHERS ARE NOTED AS DEFERRED SUBMITTALS THAT WILL INCLUDE BUT NOT BE LIMITED TO: CONCRETE MIX DESIGN PRIOR TO SUBMITTAL OF DEFERRED ITEMS TO PLAN REVIEW , THEY SHALL BE SUBMITTED TO OUR OFFICE FOR REVIEW. DEFERRED SUB ITTA S GE ERA REQUIRE E TS DRAWINGS THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEERS IN THIS OR SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKERS WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. MISCELLANEOUS ITEMS CALCULATION AND DESIGN OF MISCELLANEOUS NON-STRUCTURAL ITEMS, SUCH AS STAIRS, RAILINGS, NON-STRUCTURAL WALLS AND PREFABRICATED STRUCTURAL ITEMS, SUCH AS FLOOR AND ROOF TRUSSES, ARE NOT INCLUDED AND ARE TO BE PROVIDED BY OTHERS UNLESS SPECIFICALLY NOTED ON THESE DRAWINGS. CONSTRUCTION MEANS AND METHODS THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DESIGN AND PROVIDE ADEQUATE SHORING, BRACING, FORM-WORK, ETC... AS REQUIRED FOR THE PROTECTION OF LIFE AND PROPERTY (INCLUDING UTILITIES) DURING CONSTRUCTION. CONSTRUCTION MATERIALS SHALL BE PLACED ON THE STRUCTURE SUCH THAT THE DESIGN LOADS AS STATED HEREIN ARE NOT EXCEEDED. DIMENSIONS, INSERTS AND OPENINGS THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS, CONDITIONS AND ELEVATIONS WITH CIVIL DRAWINGS PRIOR TO START OF CONSTRUCTION. THE CONTRACTOR SHALL INFORM THE CIVIL ENGINEER IN WRITING OF ANY DISCREPANCIES OR OMISSIONS NOTED ON THE DRAWINGS. ANY SUCH DISCREPANCY, OMISSION, OR VARIATION NOT REPORTED BEFORE START OF CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. WHERE DISCREPANCIES OCCUR IN THESE DRAWINGS, NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. CONTRACTOR SHALL ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. STANDARDS WHERE REFERENCE IS MADE TO VARIOUS TEST STANDARDS FOR MATERIALS, SUCH STANDARDS SHALL BE THE EDITION REFERENCED IN THE GOVERNING BUILDING CODE. TYPICAL DETAILS AND NOTES TYPICAL DETAILS AND NOTES SHALL APPLY, THOUGH NOT NECESSARILY INDICATED AT A SPECIFIC LOCATION ON PLANS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. SHOP DRAWINGS SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS. SHOP DRAWINGS ARE REVIEWED ONLY FOR GENERAL COMPLIANCE WITH THE STRUCTURAL DRAWINGS. REVIEW DOES NOT INDICATE THAT THE SHOP DRAWINGS ARE CORRECT OR COMPLETE. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM CONTRACT DRAWINGS SHALL BE CLOUDED. ANY OF THE AFOREMENTIONED SHALL NOT BE CONSIDERED APPROVED AFTER ENGINEER'S REVIEW UNLESS SPECIFICALLY NOTED ACCORDINGLY. THE SHOP DRAWINGS DO NOT SUPERSEDE OR REPLACE THE ORIGINAL CONTRACT DRAWINGS. ANY ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SHALL BEAR THE SEAL OF AN APPROPRIATELY REGISTERED ENGINEER. DOME TECHNOLOGY SHALL NOT BE RESPONSIBLE FOR THE ADEQUACY OF ENGINEERING DESIGNS PERFORMED BY OTHERS. FIVE WORKING DAYS SHALL BE ALLOWED FOR THE ENGINEER'S REVIEW. CONTRACTOR SHALL PROVIDE A COPY OF EACH SUBMITTAL FOR DOME TECHNOLOGY' RECORDS. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 A B C D E F G H I J K L A B C D E F G H I J K L TH E S E P L A N S , D R A W I N G S A N D D E S I G N S A R E T H E E X C L U S I V E P R O P E R T Y O F D O M E T E C H N O L O G Y . A N D S H A L L N O T B E R E P R OD U C E D I N A N Y F O R M W I T H OU T W R I T T E N C O N S E N T . A L L R I G H T S A R E R E S E R V E D . C O P YR I G H T 2 0 1 9 D O M E T E C H N O L O G Y . 4946 North 2900 East, Idaho Falls, ID 83401 tel: (208) 529-0833 fax: (208) 529-0854 DOME TECHNOLOGY 14 REVISION DESCRIPTION REV. SHEET TITLE: REF NUMBER DESIGNED DRAWN CHECKED APPROVED SEAL START DATE: PROJECT NUMBER: SCALE: SHEET NIMBER: PR I N T E D : PROJECT: LOCATION: 9750PROFESSIONALE N GIN E E R I D A HO OF S T ATE REGISTER ED J ASON S O U T H C:\Users\samuel.zapata\Desktop\STEEL BUILDING CONCRETE SLAB.rvt 0 1 1/2" = 1'-0" 9/ 2 1 / 2 0 2 2 4 : 4 8 : 1 6 P M METAL BUILDING FOUNDATION FOR AARON SHEPPARD MENAN, ID GENERAL STRUCTURAL NOTES JS SZ JS JS GN001 70XX 70XX -GN001 -REV 0 -22.09.21 REV REVISION NOTE DATE YY.MM.DD DT 0 ISSUED FOR PERMIT 22.09.21 DATE 22.09.21 Roof snow load 35 Ground snow load 50 Need architectural drawings and design criteria plans showing: Use classification. Type of construction Occupant load Exits, Travel distance Sprinkled? (Please contact Stan C. with Fire Department) Site plan Special Inspector needs to be identified Etc... 36" 1 1 2 2 3 3 4 4 5 5 6 6 7 7 25' - 0"25' - 0"25' - 0"25' - 0"25' - 0"25' - 0" A A B B C C D D E E F F 15 ' - 0 " 15 ' - 0 " 15 ' - 0 " 15 ' - 0 " 15 ' - 0 " 1 SC501 2 SC501 WF30 WF 2 4 4,000 PSI 6" CONCRETE SLAB W #5 AT 18" O.C. EACH WAY OVER COMPACTED FILL T.O. SLAB = 100'-0" WF 2 4 WF 2 4 WF 2 4 WF30 WF30 WF30 DIMENSIONS PER HERITAGE BUILDING SYSTEMS DRAWINGS REV 0 DATED 8/23/22 (3) #6 AT 3" O.C. HAIR PIN W STD BEND (TYP) TYP 60.00° TYP10' - 0" COLUMN AND A.B. PER METAL BUILDING DRAWINGS PROVIDE 90° HORIZONTAL REBAR DOWEL AT ALL CORNERS TO PROVIDE CONTINOUS REINFORCING AT EDGES F U DATI P A TES A. "WF24", "WF30"... INDICATE CONTINUOUS WALL FOOTINGS, SEE FOOTING SCHEDULE THIS SHEET. SCHEDU ES A. PROVIDE CONTROL JOINTS IN CONCRETE SLAB ON GRADE PER DETAIL AND THE GN001 C CRETE A. CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. RESOLVE ANY DISCREPANCIES W/ METAL BUILDING FABRICATOR. B. SEE STEEL BUILDING PLAN FOR ALL ELEVATIONS. CONTRACTOR TO VERIFY ALL DIMENSIONS, PRIOR TO CONSTRUCTION. RESOLVE ANY DISCREPANCIES W/ METAL BUILDING FABRICATOR. C. SEE METAL BUILDING DRAWINGS FOR ALL DIMENSIONS NOT SHOWN HERE, INCLUDING LOCATION OF WALLS AND OPENINGS. ISC SC5023 / DE P T H WIDTH 2" CLR 2" CLR 4" C L R FOOTING REINFORCING SLAB REINFORCING SC5011 / SC5012 / 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 A B C D E F G H I J K L A B C D E F G H I J K L TH E S E P L A N S , D R A W I N G S A N D D E S I G N S A R E T H E E X C L U S I V E P R O P E R T Y O F D O M E T E C H N O L O G Y . A N D S H A L L N O T B E R E P R OD U C E D I N A N Y F O R M W I T H OU T W R I T T E N C O N S E N T . A L L R I G H T S A R E R E S E R V E D . C O P YR I G H T 2 0 1 9 D O M E T E C H N O L O G Y . 4946 North 2900 East, Idaho Falls, ID 83401 tel: (208) 529-0833 fax: (208) 529-0854 DOME TECHNOLOGY 14 REVISION DESCRIPTION REV. SHEET TITLE: REF NUMBER DESIGNED DRAWN CHECKED APPROVED SEAL START DATE: PROJECT NUMBER: SCALE: SHEET NIMBER: PR I N T E D : PROJECT: LOCATION: 9750PROFESSIONALE N GIN E E R I D A HO OF S T ATE REGISTER ED J ASON S O U T H C:\Users\samuel.zapata\Desktop\STEEL BUILDING CONCRETE SLAB.rvt 0 As indicated 9/ 2 1 / 2 0 2 2 4 : 4 8 : 1 6 P M METAL BUILDING FOUNDATION FOR AARON SHEPPARD MENAN, ID FOUNDATION PLAN JS SZ JS JS SC101 70XX 70XX -SC101 -REV 0 -22.09.21 1" = 10'-0"1 T.O.CONCRETE SLAB REV REVISION NOTE DATE YY.MM.DD DT 0 ISSUED FOR PERMIT 22.09.21 FOOTING SCHEDULE MARK DIMENSIONS FOOTING REINFORCING DEPTH WIDTH LENGTH WF24 30"24"CONTINUOS PER DETAIL WF30 30"30"CONTINUOS PER DETAIL DATE 22.09.21 T.O.CONCRETE SLAB 100' -0" 30 " 6" 3" C L R (4) #6 CONTINUOS TIE #5 AT 18" O.C. SLAB REINFORCING PER SC1011 / 30" PER STEEL BUILDING DWGS HAIR PIN PER SC1011 / ANCHOR BOLTS PER STEEL BUILDING DWS 2" CLR2" CLR (3) #5 CONTINUOS T.O.CONCRETE SLAB 100' -0" 6" 30 " (4) #5 CONTINUOS TIE #5 AT 18" O.C. SLAB REINFORCING PER SC1011 / 24" (3) #5 CONTINUOS PER STEEL BUILDING DWGS ANCHOR BOLTS PER STEEL BUILDING DWS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 A B C D E F G H I J K L A B C D E F G H I J K L TH E S E P L A N S , D R A W I N G S A N D D E S I G N S A R E T H E E X C L U S I V E P R O P E R T Y O F D O M E T E C H N O L O G Y . A N D S H A L L N O T B E R E P R OD U C E D I N A N Y F O R M W I T H OU T W R I T T E N C O N S E N T . A L L R I G H T S A R E R E S E R V E D . C O P YR I G H T 2 0 1 9 D O M E T E C H N O L O G Y . 4946 North 2900 East, Idaho Falls, ID 83401 tel: (208) 529-0833 fax: (208) 529-0854 DOME TECHNOLOGY 14 REVISION DESCRIPTION REV. SHEET TITLE: REF NUMBER DESIGNED DRAWN CHECKED APPROVED SEAL START DATE: PROJECT NUMBER: SCALE: SHEET NIMBER: PR I N T E D : PROJECT: LOCATION: 9750PROFESSIONALE N GIN E E R I D A HO OF S T ATE REGISTER ED J ASON S O U T H C:\Users\samuel.zapata\Desktop\STEEL BUILDING CONCRETE SLAB.rvt 0 3/4" = 1'-0" 9/ 2 1 / 2 0 2 2 4 : 4 8 : 1 6 P M METAL BUILDING FOUNDATION FOR AARON SHEPPARD MENAN, ID FOUNDATION DETAILS JS SZ JS JS SC501 70XX 70XX -SC501 -REV 0 -22.09.21 3/4" = 1'-0"1 WF30 DETAIL 3/4" = 1'-0"2 WF24 DETAIL REV REVISION NOTE DATE YY.MM.DD DT 0 ISSUED FOR PERMIT 22.09.21 DATE 22.09.21 SHA W TRE CH BE W F TI G DEEP TRE CH BE W F TI G 1 1 2' - 0" MIN TRE CH PARA E T F TI G UTILITY PIPE BOTTOM OF TRENCH PARALLEL TO FOUNDATION SHALL NOT BE CLOSER THAN 1 TO 1.5 SLOPE FROM BOTTOM EDGE OF FOOTING UTILITY PIPE 1.5 1 BOTTOM OF CONCRETE FOOTING OF FOUNDATION SLEEVE SIZE PER CIVIL DRAWING. IF CIVIL SHCEDULE NOT PROVIDED, USE SCHEDULE 40 PIPE. PROVIDE 1/2" MIN CLEARANCE AROUND UTILITY PIPIE LEAN CONCRETE FILL PLACE PRIOR TO FOOTING PLACEMENTE, FORM SAME WIDTH AS FOOTING . . CLEARANCE EQUAL TO SLEEVE DIA (6" MIN) 3' - 0 " M I N . BOTTOM OF CONCRETE FOOTING OF FOUNDATION UTILITY PIPE BACKFILL AND RECOMPACT TRENCH PER SOIL REPORT AND SPECIFICATIONS . CLEARANCE EQUAL TO SLEEVE DIA (6" MIN) 3'-0" MAX WIDTH. WHERE TRENCH WDTH EXCEEDS 3'-0" NOTIFY STRUCTURAL ENGINEER PRIOR TO PLACEMENT OF FOOTING TYP (1)1.MINUMUM FINISHED BEND DIA 6d FOR #3 THRU #8 8d FOR #9, #10 AND #11 10d FOR #14 AND #18 2.EXTENSION FOR STIRRUPS AND TIES ONLY: 90°: 6d FOR #5 AND SMALLER, 12d FOR #6 THRU #8 (3" MIN) 135°: 6d (3" MIN) 180°: 4d (2 1/2" MIN) 3.MINIMUM FINISHED BEND DIA FOR STIRRUPS AND TIES ONLY 4d FOR #5 AND SMALLER 6d FOR #6 THRU #8 4d TYP (1) TY P (1 ) d MIN 2 1/2" _____ d 12 d TYP (3) (2 ) d (2) (3) 1 3 5 .0 0 ° EY TES A. d = BAR DIA B. ALL REINFORCEMENT SHALL BE BENT COLD UNLESS NOTED OTHERWISE ON PLAN OR DETAILS C. REINFORCEMENT SHALL NOT BE UN-BENT AND RE-BENT U.N.O. TES 6 1 STIRRUP A D THE H S FFSET BAR A THER REI F RCI G SAWCUT JOINT DPETH EQUAL TO 1/4 SLAB THICKNESS COMPACTED SUBGRADE PER GSN CL R 0' - 1 " 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 A B C D E F G H I J K L A B C D E F G H I J K L TH E S E P L A N S , D R A W I N G S A N D D E S I G N S A R E T H E E X C L U S I V E P R O P E R T Y O F D O M E T E C H N O L O G Y . A N D S H A L L N O T B E R E P R OD U C E D I N A N Y F O R M W I T H OU T W R I T T E N C O N S E N T . A L L R I G H T S A R E R E S E R V E D . C O P YR I G H T 2 0 1 9 D O M E T E C H N O L O G Y . 4946 North 2900 East, Idaho Falls, ID 83401 tel: (208) 529-0833 fax: (208) 529-0854 DOME TECHNOLOGY 14 REVISION DESCRIPTION REV. SHEET TITLE: REF NUMBER DESIGNED DRAWN CHECKED APPROVED SEAL START DATE: PROJECT NUMBER: SCALE: SHEET NIMBER: PR I N T E D : PROJECT: LOCATION: 9750PROFESSIONALE N GIN E E R I D A HO OF S T ATE REGISTER ED J ASON S O U T H C:\Users\samuel.zapata\Desktop\STEEL BUILDING CONCRETE SLAB.rvt 0 1" = 1'-0" 9/ 2 1 / 2 0 2 2 4 : 4 8 : 1 6 P M METAL BUILDING FOUNDATION FOR AARON SHEPPARD MENAN, ID TYPICAL DETAILS JS SZ JS JS SC502 70XX 70XX -SC502 -REV 0 -22.09.21 1" = 1'-0"1 TYPICAL UTILITY TRENCH AT CONTINUOUS FOOTING 1" = 1'-0"2 STANDARD REBAR BENDING DETAILS 1" = 1'-0"3 SAW CUT JOINT IN CONCRETE SLAB ON GRADE REV REVISION NOTE DATE YY.MM.DD DT 0 ISSUED FOR PERMIT 22.09.21 DATE 22.09.21