HomeMy WebLinkAboutRiverwalk Apartments PHASE 1- ARCH & STRUCT 10-14-22 PERMIT REVISIONS-Reviewed-Corrections-RequiredAuthor Name Author Email Author Phone No.: Cody Jones Cody.Jones@rexburg.org 208-372-2173 Alex Owens Alex.Owens@rexburg.org 208-372-2172 Description : Riverwalk Apartments - 4 Plex - Bldg 1 Address : 301 E 7th N - Units 1101, 1102, 1201, 1202 Application Type : Document Filename : Riverwalk Apartments PHASE 1- ARCH & STRUCT 10-14-22 PERMIT REVISIONS.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments G1.1 Free Text Cody Jones : Building Open 1 Need COMM check or prescriptive insulation form signed. Stairs to comply with 1011. (riser, treads) Stair ways to rated on both sides. Need Engineered truss plans approve by Building Design Proffesional. G1.1 Free Text Alex Owens : Electrical Open 1 No electrical plans provided. Please provide electrical plans including service size and available fault current calculation. All electrical work to comply with 2017 NEC. # 22-00715 New Multi-Family Residence Please digitally re-submit all pages of the plan set in response to requested revisions for our next review cycle, with noted items resolved. Report Date: 10.19.2022 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) AREA MAP NORTH PROJECT SITE GENERAL NOTES 1. SITE CONCRETE FLATWORK THAT ABUTTS FOUNDATION SHALL UTILIZE 1/2" EXPANSION MATERIAL WITH CONTINUOUS SEALING ON TOP. 2. HORIZONTAL GYPSUM SHALL BE INSTALLED PERPENDICULAR TO CEILING FRAMING PER IBC 2508.5.2. 3. ELECTRICAL BOXES IN RATED ASSEMBLIES SHALL BE STEEL OR HAVE A LISTED FIRE-RATING EQUIVALENT TO THE ASSEMBLY. ANNULAR SPACE BETWEEEN THE MEMBRANE AND THE BOX SHALL NOT EXCEED 1/8" PER IBC 714.3.2. 4. RECESSED LUMINAIRES INSTALLED WITHIN THE BUILDING ENVELOPE SHALL COMPLY WITH IECC R402.4.5. FIXTURES SHALL BE IC-RATED AND SEALED AIR TIGHT. 5. WALL TILE IN SHOWER/TUB ENCLOSURES SHALL BE INSTALLED PER IBC 2509.2, WITH THE USE OF GLASS-MAT GYPSUM PANELS, ASTM C1178, FIBER-CEMENT BACKER BOARD, ASTM C1288, OR FIBER-MAT REINFORCED CEMENTITIOUS BACKER BOARD, ASTM C1325. 6. LANDINGS AT DOORS AND CROSS SLOPE OF SIDEWALKS NOT TO EXCEED 2%. 7. GRADING SLOPE TO BE 6" WITHIN FIRST 10' FROM BUILDING. CODE REVIEW APPLICABLE BUILDING CODES: 2018 IBC, IMC, IECC, NEC OCCUPANCY: R-2 CONSTRUCTION TYPE: V-B FIRE SPRINKLER: YES, 13-R STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : 1 10/3/22 REVIEW COMMENT RIVERWALK QUADPLEX OF DRAWING INDEX 10/14/2022 10:31:33 AM S:\Drawings\910-Leatham 4-plex Condos 2022\BIM\910- 4-Plex_2.0 (July 27 Review Comments).rvtG1.1 CO V E R S H E E T 910 RI V E R W A L K Q U A D P L E X SEP 2022 JRN BAM SEP 2022 RE X B U R G , ID A H O REXBURG,IDAHO G1.1 COVER SHEET G1.2 GENERAL ACCESSIBILITY REQUIREMENTS A1.1 MAIN & UPPER FLOOR PLANS A1.2 ROOF PLAN A2.1 EXTERIOR ELEVATIONS A2.2 EXTERIOR ELEVATIONS A3.1 BUILDING SECTIONS A3.2 TYPICAL ASSEMBLIES & DETAILS A4.1 INTERIOR ELEVATIONS S1.0 GENERAL STRUCTURAL NOTES S1.1 TYPICAL DETAILS S1.2 TYPICAL DETAILS S2.0 FOUNDATION PLAN S2.1 FLOOR FRAMING PLAN S2.2 ROOF FRAMING PLAN S3.0 FOUNDATION DETAILS S4.0 FRAMING DETAILS GENERAL ARCHITECTURAL 2 STRUCTURAL 1 CL LC CL LC LC LC CL LC #304 ROOM WASTE TOWELS TOWELS WASTE VEND. WASTE 48" AFF MAX 48" AFF MAX 48" AFF MAX TO O P E R A B L E CO N T R O L S T Y P TO D I S I P N S I N G OU T L E T T Y P TO D I S I P N S I N G OU T L E T T Y P 48" AFF MAX TO D I S I P N S I N G OU T L E T T Y P 48" AFF MAX TO OP E N I N G 19" AFF MIN 27" AFF MAX 19 AFF MIN 27" AFF MAX TOWEL DISPENSER & WASTE RECEPTACLE TOWEL DISPENSER HAND DRYER SANITARY PRODUCTS VENDOR WASTE RECEPTACLE TISSUE DISPENSER NAPKIN DISPOSAL NOTE: PROVIDE A MIN CLEAR FLOOR SPACE OF 30"x48" AT APPROACH ALONG AN ACCESSIBLE ROUTE. 33" MIN 36" MAX 12" MAX 3'-8" MIN 36" MAX 39" - 41" 39" - 41" 18" MAX 17" - 19" 1 1/4" TO 1 1/2" O.D. GRAB BAR (TYP) 18" MIN 36" MIN 6" MAX TOILET TOILET 1 1/2" MIN CLEAR TO WALL OR DISPENSERS TO DISP. OUTLET 48" MAX TO MIRROR 38" MAX 9" MIN MIN CLR WIDTH 2'-6" 29" MIN 34" MAX BO T T O M O F AP R O N TO P O F R I M INSULATE ALL EXPOSED PIPES NOTE: FLUSH VALVE HANDLE ON WIDE SIDE OF TOILET, 44" AFF MAX. NOTE: GRAB BARS MUST NOT ROTATE WITHIN THEIR FITTINGS. STANDARD ACCESSIBILITY: 1. ALL DOORS IN THE PUBLIC AND COMMON USE AREAS SHALL COMPLY WITH ANSI A117.1, INCLUDING NECESSARY MANEUVERING CLEARANCES AND ACCESSIBLE DOOR HARDWARE. THIS INCLUDES THE EXTERIOR SIDE OF THE MAIN ENTRY DOORS TO DWELLING UNITS. 2. ALL DOORS SHALL HAVE 32" MIN CLEAR WIDTH WHEN DOOR IS OPEN 90 DEGREES. 3. ALL PLUMBING FIXTURES AND APPLIANCES IN DWELLING UNITS SHALL HAVE MIN 30" x 48" CLEAR FLOOR SPACE AS REQUIRED BY FHA. 4. ALL PLUMBING FIXTURES, APPLIANCES, AND TELEPHONES IN PUBLIC AND COMMON USE AREAS SHALL COMPLY WITH ADA, IBC, AND ANSI 117.1. 6" MAX TOE 17" MIN 27" MIN 29" MIN BO T T O M O F AP R O N 34" MAX AF F T O T O P O F RI M 8" MIN KNEE CLEARANCE CLEARANCE 9" MIN 6" MAX 8" MIN 27" MIN OF SPOUT 36" MAX TOP 17"-19" 4'-11 127/128" AFF MOUNT SIGNS AT LATCH SIDE OF DOOR, OR NEAREST ADJACENT WALL. AT WALL 18" MIN CLR WIDTH 30" MIN TOP OF RIM 17" MAX FACE OF FINISHED WALL NOTES: 1. FLUSH VALVE HANDLE AT 44" AFF MAX. 2. 30" x 48" MIN CLR FLR SPACE AT APPROACH 3. 5 LBS MAX FORCE TO OPERATE FLUSH VALVE. 4. 14" MIN PROJECTION FROM WALL. 15" MIN 48" MAX ELEC. OUTLET SWITCHES, THERMOSTATS, ETC. LAVATORY, MIRROR, AND SOAP DISPENSER LAVATORY DRINKING FOUNTAIN PERMANENT ROOM SIGNAGE URINAL ELECTRICAL DEVICES NOTE: 18" MIN CLR FROM WALL TO OF LAVATORYLC NOTE: PROVIDE MIN CLEAR FLOOR SPACE OF 30" x 48" WITH 19" MAX EXTENDING UNDER LAV./D.F. TO INSULATED PIPING/PLUMBING. NOTE: FAUCETS MUST BE LEVER TYPE, ELECTRONICALLY ACTIVATED, OR APPROVED SELF-CLOSING VALVES (MIN 10 SEC. OPEN FLOW), AND BE OPERABLE w/ ONE HAND, NOT REQUIRING TIGHT GRASPING, PINCHING, OR TWISTING OF WRIST. 5 LBS. MAX FORCE REQUIRED TO ACTIVATE CONTROLS. FINISH FLOOR TYP.FINISH FLOOR TYP.FINISH FLOOR TYP. 9" 33" - 36"3" - 6" 1'-6" CONTROL END ELEVATION BACK WALL ELEVATION PLAN VIEW 33" - 36" 33" - 36"3" - 6" 1'-6" 1'-0" 24" MAX 24" MIN 12" MAX 4" MAX 24" MIN BACK WALL HE A D E N D W A L L CO N T R O L EN D W A L L 15" MIN 48" MAX 20" MAX 48" MAX •20"-25" 44" MAX 10" MAX 48" MAX 15" MIN 10" MAX 34" MAX 48" MAX 34" MAX 48" MAX •10"-24" 48" MIN 19" MAX 27" MIN 34" MAX 17" MIN 40" MAX 34" MAX 27" MIN 9" MIN 6" MAX8" MIN GUIDANCE FOR KNEE SPACES IN "A" BATHROOMS GUIDANCE FOR KNEE SPACES IN "B" BATHROOMS KNEE SPACE AT LAVATORIESOBSTRUCED HIGH SIDE REACHUNOBSTRUCTED SIDE REACHOBSTRUCTED HIGH FORWARD REACHUNOBSTRUCTED FORWARD REACH STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF 9/14/2022 5:00:38 PM \\dc01\JRWA\Drawings\910-Leatham 4-plex Condos 2022\BIM\910- 4-Plex_2.0 (July 27 Review Comments).rvtG1.2 GE N E R A L A C C E S S I B I L I T Y R E Q U I R E M E N T S 910 RI V E R W A L K Q U A D P L E X SEP 2022 JRN BAM SEP 2022 RE X B U R G , ID A H O 2 DWDW Dr y e r Wa s h e r Dr y e r W a s h e r UP DWDW DN Dr y e r W a s h e r 1 A3.1 3' - 0 " 3' - 2 " 14 ' - 9 " 22 ' - 9 " 3' - 0 " 3' - 2 " 14 ' - 9 " 22 ' - 9 " 4' - 6 " 15 ' - 9 " 2' - 6 " 6'-2 1/2"14'-2"3'-0"3'-0"14'-2"6'-2 1/2" 1'-4"1'-4" 46'-9" 44'-1" 5'-2"5'-6 1/2"3'-5 1/2"2'-11 1/4"3'-3 1/4" 4' - 6 " 18 ' - 3 " 13'-10 1/4"10'-10 3/4"19'-4" 3'-0 1/2"3'-6"3'-6"12'-4"4'-11 1/2"7'-7"4'-2"5'-0" 15'-7" 7' - 9 " 5'-0"2'-6"9'-6"2'-6" 9'-0" 7' - 9 " 4' - 1 1 1 / 2 " 43 ' - 8 " A4.1 A B A4.1DA4.1 D A4.1 B A Sim MASTER BEDROOM BEDROOM PANTRY BATH W.I.C. HVAC W.I.C. W.I.C. 4' - 4 1 / 2 " 5' - 1 1 1 / 2 " 16 ' - 6 1 / 2 " 2'-7"6'-5 1/2"4'-4"3'-8"6'-0" 5'-6 3/4"3'-5 3/4" 9" 10 ' - 9 " 4' - 0 " 2' - 8 " 5' - 1 0 1 / 4 " 5' - 3 1 / 4 " 2 A3.1 6'-2 1/2"3'-9"5'-3"5'-2" KITCHEN LIVING ROOM WH F.E F.E FIRE RISER 5 21068 21 0 6 8 21 0 6 8 21068 5068 26 6 8 24 6 8 4068 21068 3080 1' - 0 " 3'-0 1/4"4'-10 1/4"3'-0 1/4" 30 8 0 A4.1 E A4.1E A A3.2 C A3.2 C A3.2 C A3.2 1-hr fire rated wall any wall less than 10'-0" from adjacent structure/ property line to be 1-hr fire- rated 1 A3.1 5'-0"4'-2"7'-7"3'-0 1/2"4'-6"5'-11 1/4"3'-9 3/4"3'-6"3'-6"3'-0 1/2" 2'-3"2'-8 1/2" 2 A3.1 3'-0 1/4"4'-10 1/4"3'-0 1/4" 2' - 6 1 / 8 " 15 ' - 8 7 / 8 " 4' - 6 " 4' - 1 1 1 / 2 " 22 ' - 9 " 14 ' - 9 " 3' - 2 " 45 ' - 7 1 / 2 " 13'-10 1/4"10'-10 3/4"19'-4" 44'-1" 4' - 1 1 1 / 2 " 22 ' - 9 " 14 ' - 9 " 3' - 2 " 18 ' - 3 " 4' - 6 " 45 ' - 7 1 / 2 " 6'-2 1/2"9'-0"8'-2"8'-2"9'-0"2'-11 1/4"3'-3 1/4" 6'-2 1/2"17'-2"17'-2"6'-2 1/2" 46'-9" 13 ' - 7 1 / 2 " 2' - 5 1 / 2 " A4.1 C A Sim A4.1D A4.1 C ASim A4.1 D STAIR F.E.C 24x36 typ. attic access 24x36 typ. attic access 21068 21 0 6 8 21 0 6 8 21068 5068 24 6 8 21068 3080 ul 20 min. rated 3080 ul 20 min. rated 26 6 8 LIVING ROOM KITCHEN BATH BEDROOM MASTER BEDROOM W.I.C. W.I.C. W.I.C. 4' - 4 1 / 2 " 5' - 1 1 1 / 2 " 16 ' - 6 1 / 2 " 2'-7"6'-5 1/2"4'-4"3'-8"6'-0" 5'-6 3/4"3'-5 3/4" 9" 2' - 9 3 / 4 " 5' - 1 0 1 / 4 " 5' - 3 1 / 4 " 1'-4" PANTRY HVAC F.E F.E A4.1EA4.1 E A A3.2 C A3.2 C A3.2 C A3.2 C A3.2 STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D 1 10/3/22 REVIEW COMMENT OF 10/14/2022 10:28:23 AM S:\Drawings\910-Leatham 4-plex Condos 2022\BIM\910- 4-Plex_2.0 (July 27 Review Comments).rvt A1.1 MA I N & U P P E R F L O O R P L A N S 910 RI V E R W A L K Q U A D P L E X SEP 2022 JRN BAM SEP 2022 RE X B U R G , ID A H O 7 SCALE:1/4" = 1'-0" 1ST FLOOR NSCALE:1/4" = 1'-0" 2ND FLOOR N fire extinguishers FE: • 1A;10B;C • FIRE EXTINGUISHER. FEC: • 4A;60B;C • SURFACE MOUNTED FIRE EXTINGUISHER CABINET. FIELD VERIFY LOCATION WITH FIRE MARSHALL PRIOR TO INSTALLATION. fire blocking 1. provide fire blocking at floor and ceiling levels. 2. provide fire blocking horizontally at intervals not to exceed 10-feet. operable windows upper level operable windows with sills within 36" of the floor shall comply with astm f2090 & ibc section 1030.2 (opening control device) notes 1. dashed area represents fha clearance requirements. (Main floor only) 2. all dimension are from face of stud (U.N.O.) 3. INTERNAL DIMENSIONS ARE TYPICAL OF ALL UNITS. 4. DELETE KITCHEN WINDOW WHEN ADJACENT UNIT IS CLOSER THAN 10'-0". 5. INSTALL 2X10 BACKING IN MARKED WALLS FOR ADAPTABLE GRAB BAR. INSTALL SO THAT CENTER OF BACKING IS AT REQUIRED HEIGHT -SEE SHEET G1.2 FOR GRAB BAR LOCATIONS. accessibility all units on lower floors to be constructed as type 'b' accessible units. 1 1 1 1 1 1 1 1 1'-0" 6' - 9 " 13'-7" 1' - 0 " 14'-6" 2" 2" 1 2 3 55 5 6 6 7 6 7 A A1.2 5 T.O. PARAPET 25'-4" T.O. ROOF STRUCTURE 21'-8 1/2" 5/8" TYPE 'X' GYP. BOARD CEILING PRE-ENGINEERED ROOF TRUSS 3/4" PLYWOOD SHEATHING 6" RIGID INSULATION SINGLE PLY MEMBRANE ROOFING EIFS WALL SYSTEM CUSTOM METAL GRAVEL STOP - 1" EXTERIOR REVEAL -COLOR TO MATCH EIFS 1" 4" 18 " M I N . SINGLE PLY MEMBRANE ROOFING SYSTEM ROOF VENT SHEET METAL FLASHING -1" DOWN INTO PIPE SEALANT SINGLE PLY MEMBRANE FLASHING STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF 9/14/2022 5:00:34 PM \\dc01\JRWA\Drawings\910-Leatham 4-plex Condos 2022\BIM\910- 4-Plex_2.0 (July 27 Review Comments).rvtA1.2 RO O F P L A N 910 RI V E R W A L K Q U A D P L E X SEP 2022 JRW BAM SEP 2022 RE X B U R G , ID A H O 7 SCALE:1/4" = 1'-0" T.O. PARAPET N KEY NOTES - ROOF PLAN 1 white single ply membrane roof over 6" rigid insulation over 3/4" plywood sheathing ON engineered truss. typ. 2 white single ply membrane roof over 6" rigid insulation over 3/4" plywood sheathing oN STRUCTURE. SEE STRUCTURAL 3 white single ply membrane roof over walk-off board over 3/4" sheathing over structure. 5 PREFINISHED METAL SCUPPER LOCATION. COLOR TO MATCH EXTERIOR EIFS COLOR - SEE ELEVATIONS 6 EIFS DETAIL - SEE ELEVATIONS 7 BLACK PREFINISHED TUBE STEEL AWNING SCALE:1" = 1'-0" ROOF DETAIL @ PARAPET A A1.2SCALE:1 1/2" = 1'-0" TYP. PENETRATION THROUGH ROOF B A1.2 1ST FLOOR 0" 2ND FLOOR 10'-7 3/4" T.O. PARAPET 25'-4" 2'-6"9'-6"2'-6" 2' - 6 " 19 ' - 5 " 4' - 2 1 / 4 " 1' - 0 " 10 ' - 0 " 10 ' - 1 3 / 4 " 4'-8 3/4" 1'-0"12'-7" 1'-10 1/2" 3'-0"1'-5 3/4"3'-0"1'-10 1/2" 1' - 0 " T.O. ROOF STRUCTURE 21'-8 1/2" 1' - 0 " 21 ' - 1 1 " 16 ' - 6 " 3' - 7 " 8' - 0 " 4' - 1 1 " 1ST FLOOR HEADER 8'-0" 2ND FLOOR HEADER 18'-7 3/4" 8' - 0 " 2' - 7 3 / 4 " 8' - 0 " 1 1 2 2 3 3 34 5 6 1 7 8 2660 2660 2660 2660 2660 2660 storefront 3050 storefront 3060 3060 3060 3060 3080 ext. door to have lever hardware 1' - 0 " A A2.1 10 9 11 11 TYP. TYP. 1 1/2" eifs system prefinished j-trim to match siding mtl. siding over air infiltration barrier STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF 9/14/2022 5:00:35 PM \\dc01\JRWA\Drawings\910-Leatham 4-plex Condos 2022\BIM\910- 4-Plex_2.0 (July 27 Review Comments).rvtA2.1 EX T E R I O R E L E V A T I O N S 910 RI V E R W A L K Q U A D P L E X SEP 2022 JRN BAM SEP 2022 RE X B U R G , ID A H O 7 SCALE:1/2" = 1'-0" FRONT ELEVATION KEY NOTES - Building ELEVATIONS 1 EIFS - WHITE COLOR 2 EIFS - BLACK COLOR 3 EIFS - SAND COLOR 4 METAL SIDING - WESTERN STATES T-8 pLANKWALL IN 'WALNUT' COLOR OR SIMILAR 5 STONE VENEER 6 PREFINISHED TUBE STEEL AWNING 7 PREFINISHED METAL SCUPPER - COLOR TO MATCH EIFS 8 BUILDING ADDRESS LOCATION MAY VARY DEPENDING ON BUILDING ORIENTATION 4" MIN HEIGHT 9 6X6X1/2 STEEL PLATE, PAINT 10 1" DIA. STEEL SCH. 40, PAINT 11 TEMPERED GLAZING XXXX 1. ALL MECHANICALLY FASTENED FLASHING SHALL BE EXTENDED UP WALL A MINIMUM OF 9". 2. sELF-ADHERED FLASHING OF SELF-HEALING NATURE SHALL BE USED AT FASTENER PENETRATIONS AT ALL HEADS AND JAMBS. 3. fLASHING TO BE APPLIED OVER SOLID BACKING PER MANUFACTURER'S INSTRUCTIONS. 4. dOOR / WINDOW FRAME SHALL NOT BE USED AS CLADDING TERMINATION. INSTALL PER AAMA 2400-10, WHICH REQUIRES A 1/4" MINIMUM JOINT FOR CLADDING EXPANSION AND CONSTRACTION. FILL JOINT WITH BACKER ROD AND COMPATIBLE SEALANT PER PROCEDURE 5.5, 6.4, AND 6.5. "J" MOLD SHALL BE USED TO TERMINATE SIDING AT JAMBS AND SILLS AS REQUIRED. INSTALL PER SIDING MANUFACTURER'S WRITTEN INSTRUCTIONS. 5. AT DOOR / WINDOW HEADS, INSTALL RIGID DRIP FLASHING IN ADDITION TO MEMBRANE FLASHING. SET FLASHING IN BED OF MASTIC. NO SEALANT SHALL BE PLACED BETWEEN THE CLADDING AND DRIP EDGE. 6. PERIMETER WINDOW / DOOR VOIDS SHALL BE FILLED WITH LOW-EXPANSION URETHANE FOAM. 7. EXTERIOR WALL PENETRATIONS, SUCH AS VENTS, ELECTRICAL PANELS, UTILITY VAULTS, FIRE EXTINGUISHER CABINETS, AND SO FORTH SHALL BE FLASHED AS A DOOR / WINDOW. 8. WINDOW SILL WEEP HOLES SHALL NOT BE BLOCKED, THEY MUST BE OPEN. TYPICAL NOTES SCALE:1 1/2" = 1'-0" CLADDING TRANSITION DETAIL A A2.1 D D D D D E E EEFD 30803080 RECESS IN WALL? NO GLASS. MATCH INTERIOR DOOR STYLE 2050 FOUNDATION WATER PROOFING (ASPHALT EMULSION) ANCHOR BOLTS 1/2" x MIN. 7" EMBEDMENT x BENT AT 48" O/C 4'-0" 2" RIGID INSULATION 2" RIGID FOUNDATION INSULATION CONC. FOOTING FINISH GRADEFINISHED FLOOR ELEV.100'-0" TOP OF FOOTING ELEV.97'-0" 2x6 TREATED SEAL PLATE COMPACTED ENGINEERED FILL 4" FREE DRAINING GRAVEL UNDER SLAB VAPOR BARRIER (BELOW GRAVEL) 4" CONCRETE SLAB 8" CONC. FOUNDATION WALL 1ST FLOOR 0" 2ND FLOOR 10'-7 3/4" T.O. PARAPET 25'-4" 2 A3.1 1 2 3 4 5 7 LIVING ROOMBATH 7 8 BATH STAIR 99 13 11 11 12 1' - 0 " T.O. ROOF STRUCTURE 21'-8 1/2" 14 15 16 6 18 17 2' - 1 1 / 4 " 1ST FLOOR HEADER 8'-0" 2ND FLOOR HEADER 18'-7 3/4" A3.1 A 12 14 5 1 2 4 8" M I N 19 20 19 20 3' - 0 " 1'-0" 1ST FLOOR 0" 2ND FLOOR 10'-7 3/4" T.O. PARAPET 25'-4" 1 A3.1 8 8 9 T.O. ROOF STRUCTURE 21'-8 1/2" 11 12 11 10 14 A1.2 A 1ST FLOOR HEADER 8'-0" 2ND FLOOR HEADER 18'-7 3/4" 1 2 4 5 6 541 3 19 20 19 20 A3.1 C (3) 2x12 stringers (2) layers type 'x' gyp. board wood framed stair. tread and riser finish per owner. 19 EVEN TREADS rubber treads STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF 9/14/2022 5:00:37 PM \\dc01\JRWA\Drawings\910-Leatham 4-plex Condos 2022\BIM\910- 4-Plex_2.0 (July 27 Review Comments).rvtA3.1 BU I L D I N G S E C T I O N S 910 RI V E R W A L K Q U A D P L E X SEP 2022 JRN BAM SEP 2022 RE X B U R G , ID A H O 7 SCALE:1/4" = 1'-0" Section 1 SCALE:1/4" = 1'-0" Section 2 KEY NOTES - Building Section 1 COMPACTED ENGINEERED FILL 2 UNDER SLAB VAPOR BARRIER 3 4" FREE DRAINING GRAVEL 4 2" RIGID FOUNDATION INSULATION 5 FOUNDATION WATER PROOFING 6 4" CONCRETE SLAB ON GRADE 7 CONTINUOUS AIR INFILTRATION BARRIER ON EXTERIOR WALL SHEATHING - TYP. 8 1-HOUR FIRE RATED SOUND WALL - SEE e/a3.2 9 1-HOUR FIRE RATED SOUND FLOOR/CEILING ASSEMBLY - SEE e/a3.2 10 SOUND INSULATION 11 EXTERIOR WALL BATT INSULATION 12 6" ROOF RIGID INSULATION 13 (2) LAYERS 5/8" TYPE 'X' GYP. BOARD 14 SINGLY-PLY MEMBRANE ROOFING MATERIAL 15 PRE-FINISHED METAL SCUPPER 16 WOOD FRAMED STAIR. (3) 2X12 STRINGERS. FILL SPACE BETWEEN STEPS AND CEILING WITH SPRAY-IN FOAM INSULATION 17 1 1/2" ROUND TUBE STEEL HANDRAIL - PAINTED. ATTACH AT 6'-0" O.C. MAX ON BOTH SIDES OF STAIR. 12" EXTENSION AT TOP OF STAIR MUST RETURN TO WALL. 11" EXTENSION AT BOTTOM OF STAIR MUST DROP AND RETURN TO POST/WALL - SEE FRONT ELEVATION. 18 UNCONDITIONED SPACE 19 SET SILL PLATE ON SILL SEALER, TYP. 20 FINISH GRADE SLOPE 5% AWAY FROM BUILDING FOR 10 FEET MIN. SCALE:1" = 1'-0" DETAIL -STAIR SECTION A A3.1 • EXTERIOR WALL R21 • ROOF R38 • FOUNDATION WALL R20 • SOUND INSULATED FLOOR R11 MINIMUM INSULATION 'R' VALUES SCALE:1 1/2" = 1'-0" TYP. EXTERIOR WALL PENETRATION (DOOR / WINDOW)B A3.1 SCALE:3/4" = 1'-0" DETAIL -FOUNDATION SECTION C A3.1 CHANGE TO CONCRETE PAN W/ FULL RISERS ELIMINATE SMALL PEICE OF INSULATION 1ST FLOOR 0" 2ND FLOOR 10'-7 3/4" T.O. PARAPET 25'-4" 1 A3.1 T.O. ROOF STRUCTURE 21'-8 1/2" 3 1 2 1 6 6" 10 ' - 1 3 / 4 " 1' - 0 " 2"2" 1' - 0 " 2 1 4050 4050 4050 40505050 5050 5050 5050 3068 1ST FLOOR 0" 2ND FLOOR 10'-7 3/4" T.O. PARAPET 25'-4" 2 A3.1 T.O. ROOF STRUCTURE 21'-8 1/2" 1ST FLOOR HEADER 8'-0" 2ND FLOOR HEADER 18'-7 3/4" 6 3 2 1 1 3 1 1 7 4650 4650 6" 1' - 0 " 2 A3.1 3 6 2 1 3 2 1 4 5 7 7 1 3080 ext. door to have lever hardware 2660 4650 4650 1' - 0 " 1' - 0 " 6" STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF 9/14/2022 5:00:36 PM \\dc01\JRWA\Drawings\910-Leatham 4-plex Condos 2022\BIM\910- 4-Plex_2.0 (July 27 Review Comments).rvtA2.2 EX T E R I O R E L E V A T I O N S 910 RI V E R W A L K Q U A D P L E X SEP 2022 JRN BAM SEP 2022 RE X B U R G , ID A H O 7 KEY NOTES - Building ELEVATIONS 1 EIFS - WHITE COLOR 2 EIFS - BLACK COLOR 3 EIFS - SAND COLOR 4 METAL SIDING - WESTERN STATES T-8 pLANKWALL IN 'WALNUT' COLOR OR SIMILAR 5 STONE VENEER 6 PREFINISHED TUBE STEEL AWNING 7 PREFINISHED METAL SCUPPER - COLOR TO MATCH EIFS 8 BUILDING ADDRESS LOCATION MAY VARY DEPENDING ON BUILDING ORIENTATION 4" MIN HEIGHT 9 6X6X1/2 STEEL PLATE, PAINT 10 1" DIA. STEEL SCH. 40, PAINT 11 TEMPERED GLAZING SCALE:1/4" = 1'-0" REAR ELEVATION SCALE:1/4" = 1'-0" RIGHT ELEVATION SCALE:1/4" = 1'-0" LEFT ELEVATION 1. ALL MECHANICALLY FASTENED FLASHING SHALL BE EXTENDED UP WALL A MINIMUM F 9". 2. sELF-ADHERED FLASHING OF SELF-HEALING NATURE SHALL BE USED AT FASTENER PENETRATIONS AT ALL HEADS AND JAMBS. 3. fLASHING TO BE APPLIED OVER SOLID BACKING PER MANUFACTURER'S INSTRUCTIONS. 4. dOOR / WINDOW FRAME SHALL NOT BE USED AS CLADDING TERMINATION. INSTALL PER AAMA 2400-10, WHICH REQUIRES A 1/4" MINIMUM JOINT FOR CLADDING EXPANSION AND CONSTRACTION. FILL JOINT WITH BACKER ROD AND COMPATIBLE SEALANT PER PROCEDURE 5.5, 6.4, AND 6.5. "J" MOLD SHALL BE USED TO TERMINATE SIDING AT JAMBS AND SILLS AS REQUIRED. INSTALL PER SIDING MANUFACTURER'S WRITTEN INSTRUCTIONS. 5. AT DOOR / WINDOW HEADS, INSTALL RIGID DRIP FLASHING IN ADDITION TO MEMBRANE FLASHING. SET FLASHING IN BED OF MASTIC. NO SEALANT SHALL BE PLACED BETWEEN THE CLADDING AND DRIP EDGE. 6. VERITCAL LAPS IN WEATHER BARRIER ABOVE AND BELOW WINDOWS / DOORS AND WITHIN 16" OF JAMBS ARE PROHIBITED. 7. PERIMETER WINDOW / DOOR VOIDS SHALL BE FILLED WITH LOW-EXPANSION URETHANE FOAM. 8. EXTERIOR WALL PENETRATIONS, SUCH AS VENTS, ELECTRICAL PANELS, UTILITY VAULTS, FIRE EXTINGUISHER CABINETS, AND SO FORTH SHALL BE FLASHED AS A DOOR / WINDOW. 9. WINDOW SILL WEEP HOLES SHALL NOT BE BLOCKED, THEY MUST BE OPEN. TYPICAL NOTES A A AA B B B B C C C C D 4046 4046 4046 4046 8' HEAD 8' HEAD X36'' AFF 4646 30" NO GLASS ON DOOR. MATCH INTERIOR DOOR 1ST FLOOR 0" 2ND FLOOR 10'-7 3/4" T.O. ROOF STRUCTURE 21'-8 1/2" EXTEND WALL ASSEMBLY TO UNDER SIDE OF FLOOR SHEATHING provide 2X blocking for gyp. board provide 2X blocking for gyp. board pre-engineered floor truss pre-engineered roof truss foundation -see structural double 2x4 stud wall @ 16" o.c. -stagger stud 5/8" type 'x' gyp. board sound attenuation batt insulation. sound trans- mission class of not less than 50. SEAL ALL PENETRATIONS BY AN APPROVED MEANS TO MAINTAIN FIRE RATING 5/8" TYPE 'X' GYP. BD. EA. SIDE 2x STUD WALL @ 16" O.C. SEAL ALL PENETRATIONS BY AN APPROVED MEANS TO MAINTAIN FIRE RATING 5/8" TYPE 'X' GYP. BD. EA. SIDE 2x6 STUD WALL @ 16" O.C. SEAL ALL PENETRATIONS BY AN APPROVED MEANS TO MAINTAIN FIRE RATING SHEATHING -SEE STRUCTURAL 3-1/2" BLOWN-IN CELLULOSE INSULATION EXTERIOR WALL FINISH -SEE PLAN 2" SPRAY-IN POLYURETHANE FOAM INSULATION (2) LAYERS 5/8" TYPE 'X' GYP. BOARD SOUND ATTENUATING BATT INSULATION. sound trans-mission class of not less than 50. PRE-ENGINEERED FLOOR TRUSS 3/4" PLYWOOD SHEATHING 1" GYPCRETE OVER 6 M. VAPOR BARRIER SEAL ALL PENETRATIONS BY AN APPROVED MEANS TO MAINTAIN FIRE RATING 1/ 2 " M A X MATCH JAMB WIDTH EXTERIOR CONC. SLAB CONC. FOUNDATIO N WALL - SEE METAL THRESHOLD SET IN SEALANT DOOR INTERIOR CONC. SLAB FLOORING MATERIAL WHERE APPLICABLE MAX SLOPE: 1:12 3' - 0 " 11" 1'-0" RETURN HANDRAIL TO BE FLUSH WITH WALL. RETURN HANDRAIL TO BE FLUSH WITH WALL. STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D 1 10/3/22 REVIEW COMMENT OF 10/14/2022 10:30:55 AM S:\Drawings\910-Leatham 4-plex Condos 2022\BIM\910- 4-Plex_2.0 (July 27 Review Comments).rvt A3.2 TY P I C A L A S S E M B L I E S & D E T A I L S 910 RI V E R W A L K Q U A D P L E X SEP 2022 JRN BAM SEP 2022 RE X B U R G , ID A H O 7 SCALE:1/2" = 1'-0" 1-HR RATED COMMON WALL A A3.2 SCALE:1 1/2" = 1'-0" 1-HR RATED INTERIOR WALL B A3.2SCALE:1 1/2" = 1'-0" 1-HR RATED EXTERIOR WALL C A3.2SCALE:1 1/2" = 1'-0" 1-HR FIRE RATED FLOOR / CEILING D A3.2 SCALE: N.T.S TYP. GROUND LEVEL THRESHOLD E A3.2SCALE:3/4" = 1'-0" HANDRAIL DETAIL F A3.2 1 1 1 2"2'-0"2'-0"2'-0" 3' - 6 " 1' - 6 " 3' - 0 " 2'-3"2'-0"2'-0"2'-0"2" 4"2'-11 1/4"2'-9"1'-11 3/4"2" 3' - 0 " 8' - 0 " 1'-10"2'-9" 2' - 7 " 1'-6" 33" MINIMUM 3'-3"2'-9"1'-11 3/4"2" 3' - 0 " 8' - 0 " see note 3'-6" 3'-0" note: verify clearances with w/d manufacturer wood shelfclothes rod countertop STATE OF IDAHO BRENT A. McFARLAND AR-2561 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 F A X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: STRUCTURAL ENGINEERING Frost Structural Engineering 1020 Lincoln Road Idaho Falls, ID 83401 Tel: (208) 227-8404 Fax: (208) 227-8405 Checked By: Plot Date: Consultants: Drawing Number: File: Revisions: Pr o j e c t : Dr a w i n g T i t l e : ® J R W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E PR O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O TA L O W N E R S H I P A N D C O N T R OL . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D EA S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T I S P R O HI B I T E D OF 9/14/2022 5:00:37 PM \\dc01\JRWA\Drawings\910-Leatham 4-plex Condos 2022\BIM\910- 4-Plex_2.0 (July 27 Review Comments).rvtA4.1 IN T E R I O R E L E V A T I O N S 910 RI V E R W A L K Q U A D P L E X SEP 2022 JRN BAM SEP 2022 RE X B U R G , ID A H O 7 SCALE:1/2" = 1'-0" KITCHEN A & B -NORTH A A4.1SCALE:1/2" = 1'-0" KITCHEN A -SOUTH B A4.1SCALE:1/2" = 1'-0" BATHROOM VANITY D A4.1 SCALE:1/2" = 1'-0" KITCHEN B -SOUTH C A4.1 SCALE:1/2" = 1'-0" LAUNDRY E A4.1 34" ADA BACKSPLASH CHANGE TO 3 EVEN SIZED DRAWERS SHELF CLOTHING ROD CLOTHING ROD 24" DEEP BACKSPLASH NO BACKSPLASH 5' - 0 " 5" TALL5" TALL JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-320 PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 9/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING GENERAL STRUCTURAL NOTES (APPLY UNLESS NOTED OTHERWISE ON PLANS/DETAILS) GENERAL REQUIREMENTS: 1.THE STRUCTURAL SYSTEMS AND MEMBERS DEPICTED HEREIN HAVE BEEN DESIGNED PRIMARILY TO SAFEGUARD AGAINST MAJOR STRUCTURAL DAMAGE AND LOSS OF LIFE, NOT TO LIMIT DAMAGE OR MAINTAIN FUNCTION (IBC SECTION 101.3). 2.THESE DRAWINGS, AND THEIR ASSOCIATED STRUCTURAL CALCULATIONS, HAVE BEEN PERFORMED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEER'S IN THIS OR SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE INTERNATIONAL BUILDING CODE CONVENTIONAL FRAMING REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR FRAMING ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3.THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION SUCH THAT DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, AND SHALL COORDINATE ALL DETAILS. 4.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. TYPICAL DETAILS AND NOTES ARE NOT NECESSARILY INDICATED ON THE PLANS, BUT SHALL APPLY NONE-THE-LESS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. 5.ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT AND STRUCTURAL ENGINEER. 6.ANY INSPECTIONS, SPECIAL (IBC CHAPTER 17) OR OTHERWISE THAT ARE REQUIRED BY THE BUILDING CODES, LOCAL BUILDING DEPARTMENTS, OR BY THESE PLANS SHALL BE DONE BY AN INDEPENDENT INSPECTION COMPANY OR THE BUILDING DEPARTMENT, SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR. BASIS FOR DESIGN: 1.BUILDING CODE: 2018 EDITION OF THE IBC WITH CITY/COUNTY AMENDMENTS. RISK CATEGORY = II 4. SEISMIC DESIGN PARAMETERS: ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE IMPORTANCE FACTOR Ie = 1.00 SITE CLASS D SEISMIC DESIGN CATEGORY D MAPPED SPECTRAL RESPONSE ACCELERATIONS S1 = 0.142, SS = 0.366 DESIGN SPECTRAL RESPONSE ACCELERATIONS SD1 = 0.22, SDS = 0.368 PERCENT SNOW INCLUDED WITH SEISMIC LOADS 20 VERTICAL SHEAR TRANSFER ELEMENTS: PLYWOOD SHEARWALL(S)R = 6.5, CS = 0.066 5. WIND DESIGN PARAMETERS (STRENGTH): ULTIMATE WIND SPEED 115 MPH (3 SECOND GUST) WIND EXPOSURE C IMPORTANCE FACTOR Iw = 1.00 INTERNAL PRESSURE COEFFICIENT -0.18 COMPONENT AND CLADDING PRESSURE 30.2 PSF NET UPLIFT ON ROOF 37.3 PSF 2. VERTICAL LOADS: LOCATION LIVE / SNOW LOAD DEAD LOAD ROOF 35 PSF 18 PSF FLOOR 40 PSF 27 PSF STAIRS 100 PSF 40 PSF 3. DEFLECTION LIMITS: ELEMENTS LIVE LOAD TOTAL LOAD ROOF TRUSSES/JOISTS L/360 L/240 FLOOR TRUSSES/JOISTS L/600 L/240 BEAMS L/360 L/240 FOUNDATION NOTES: 1.IN LIEU OF A GEOTECHNICAL REPORT: THE FOUNDATION HAS BEEN DESIGNED ACCORDING TO THE RECOMMENDATIONS OF CHAPTER 18 OF THE IBC. 2.THE SOIL DESIGN VALUES LISTED BELOW HAVE BEEN APPROVED BY THE CITY/COUNTY BUILDING DEPARTMENT, CONTINGENT THAT THE SOIL ON THE SITE PREDOMINATELY CONSISTS OF SAND AND/OR GRAVEL. SPECIFIC SOIL CLASSIFICATIONS SHOULD BE ONE OF THE FOLLOWING: SANDY GRAVEL OR GRAVEL(GW OR GP), SAND(SW AND SP), SILTY SAND(SM), CLAYEY SAND(SC), SILTY GRAVEL(GM), OR CLAYEY GRAVEL(GC). THESE SOIL CLASSIFICATIONS CAN BE FOUND IN TABLE 1806.2 OF CHAPTER 18 OF THE IBC. VERIFICATION OF SOIL CLASSIFICATION IS THE RESPONSIBILITY OF THE CONTRACTOR. 3.A ONE-THIRD INCREASE IN BEARING PRESSURES IS ALLOWED WITH SEISMIC OR WIND LOAD COMBINATIONS. LATERAL BEARING AND LATERAL SLIDING RESISTANCE MAY BE COMBINED. 4.ALL FOUNDATIONS SHALL BEAR ON COMPACTED ENGINEERED FILL OR COMPETENT NATIVE SOIL SUBBASE COMPACTED TO 95% DRY DENSITY (STANDARD PROCTOR). GRADE IS DEFINED AS LOWEST ADJACENT GRADE WITHIN 5 FEET OF THE BUILDING FOR PERIMETER FOOTINGS. WHERE EXTERIOR PAVING OR CONCRETE IS DIRECTLY ADJACENT TO BUILDING, GRADE IS DEFINED AS TOP OF EXTERIOR PAVING AT LEAST 5 FEET FROM BUILDING. CONCRETE FOOTING EXCAVATIONS SHALL BE CLEAN AND FREE OF LOOSE DEBRIS OR UN-COMPACTED MATERIAL AT TIME OF CONCRETE PLACEMENT. 5.CONCRETE SLABS ON GRADE SHALL BE SUPPORTED ON A 4 INCH (MIN) LAYER OF FREE-DRAINING GRANULAR MAT (DRAINAGE FILL COURSE). THE MAT SHOULD CONSIST OF A WELL GRADED SAND AND GRAVEL MIXTURE WITH MAXIMUM 3/4-INCH CRUSHED AGGREGATE. THE GRANULAR MAT SHOULD BE COMPACTED TO NO LESS THAN 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557. 6.BACKFILL AGAINST RESTRAINED WALLS SHALL NOT BE PLACED UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION OF INTERIOR FLOOR SYSTEMS AND CONCRETE OR GROUT STRENGTH HAS REACHED THE 28 DAY STRENGTH LISTED BELOW. THE SOIL DESIGN VALUES FOR THE FOUNDATION ARE: ALLOWABLE BEARING PRESSURE 1500 PSF ALLOWABLE LATERAL BEARING PRESSURE 150 PSF/FT ALLOWABLE LATERAL SLIDING COEFFICIENT 0.25 FOUNDATION BEARING DEPTH 36" BELOW FINISHED GRADE CONCRETE: 2.ALL NORMAL WEIGHT CONCRETE SHALL BE REGULAR WEIGHT OF 150 POUNDS PER CUBIC FOOT USING HARD-ROCK AGGREGATES. AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. 3.LAP SPLICES FOR BEAMS AND FLOOR SLABS SLABS SHALL BE ACCORDING TO CHAPTER 12 OF ACI 318 OR LAP SCHEDULE ON THESE DRAWINGS. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. LATEST ACI CODE AND DETAILING MANUAL APPLY. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO CENTER OF STEEL. MINIMUM COVER FOR NON-PRESTRESSED CONCRETE REINFORCING SHALL BE AS FOLLOWS: 5.MAXIMUM SLUMP FOR ALL CONCRETE SHALL BE 6". PORTLAND CEMENT SHALL CONFORM TO ASTM C150. TYPE V CEMENT SHALL BE USED FOR CONCRETE IN CONTACT WITH ALKALINE SOIL, AND TYPE II ELSEWHERE. 6.NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY THE TESTING AGENCY. 7.CONCRETE PLACEMENT AND QUALITY SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301 AND ACI 318. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AROUND AND UNDER FLOOR DUCTS, ETC. CAST CLOSURE POUR, WHERE SHOWN ON PLANS AROUND COLUMNS AFTER COLUMN DEAD LOAD IS APPLIED. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING CONCRETE. ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING, DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY POSITIONED IN THE FORMS BEFORE PLACING THE CONCRETE. 8.ALL CONCRETE SLABS ON GRADE SHALL BE DIVIDED INTO AREAS BY CONTROL JOINTS (KEYED OR SAW CUT) SUCH THAT ONE SLAB AREA DOES NOT EXCEED A MAXIMUM LENGTH OF 24 TIMES THE SLAB THICKNESS IN BOTH DIRECTIONS (EXAMPLE: 4" SLAB = 8'-0" LENGTH). SQUARE LAYOUTS ARE PREFERRED, BUT THE SLAB GEOMETRY MAY DICTATE OTHERWISE. THE RATIO OF THE LONG TO SHORT DISTANCE SHALL NOT EXCEED 1.3. IT IS RECOMMENDED THAT SAW CUTS BE MADE WITHIN 16 HOURS OF CONCRETE BATCHING. KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. 9.HORIZONTAL PIPES AND ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE AND SLABS ON GRADE EXCEPT WHERE SPECIFICALLY APPROVED OR NOTED BY THE STRUCTURAL ENGINEER. PIPES AND CONDUITS SHALL NOT IMPAIR THE STRENGTH OF THE WORK. 10.FLY ASH MAY BE USED ONLY IF PERMITTED BY ARCHITECTURAL SPECIFICATIONS AND SHALL BE LIMITED TO 18 PERCENT OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE. 11.COLD/HOT WEATHER CONCRETE CONSTRUCTION: PROTECT CONCRETE FROM DAMAGE OR REDUCED STRENGTH IN COMPLIANCE WITH ACI 305 AND 306. 12.CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. 13.LIMIT ALKALI-SILICA REACTION (ASR) TO 0.1% EXPANSION AT 28 DAYS IN CONCRETE MIX AT ALL EXTERIOR CONCRETE AND INTERIOR CONCRETE EXPOSED TO MOISTURE. LOCATION:MINIMUM COVER TOLERANCE CAST AGAINST EARTH (FOOTINGS)3"± 3 8" SLABS ON GRADE 112"± 14" EXPOSED TO EARTH OR WEATHER - #5 AND SMALLER 112"± 3 8" EXPOSED TO EARTH OR WEATHER - #6 AND LARGER 2"± 3 8" NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND ROOF SLAB 1"18" STRUCTURAL SLABS AND WALLS 3 4"18" BEAMS AND COLUMNS (PRIMARY) REINFORCEMENT, TIES, STIRRUPS AND SPIRALS 112"3 8" 1. MINIMUM 28 DAY CONCRETE STRENGTH SHALL BE AS FOLLOWS: USE:CONCRETE STRENGTH: MAX W/C RATIO AIR ENTRAINMENT FOOTINGS 3500 PSI 0.50 5.5% ± 1% FOUNDATION WALLS 4500 PSI 0.45 5.5% ± 1% INTERIOR CONCRETE SLABS ON GRADE 3500 PSI 0.45 N/A REINFORCING STEEL: 1.ASTM A615 GRADE 60 (FY = 60 KSI) DEFORMED BARS FOR ALL BARS #4 AND LARGER. ASTM A615 GRADE 40 (FY = 40 KSI) DEFORMED BARS FOR ALL BARS #3 AND SMALLER. GRADE 60 DEFORMED BARS SHALL BE USED FOR CONCRETE WALLS, BEAMS, ELEVATED SLABS AND COLUMN REINFORCING. 2.WELDING OF REINFORCING BARS SHALL BE MADE ONLY TO ASTM A706 GRADE 60 BARS AND ONLY USING E90 SERIES RODS. WELDING OF REINFORCING BARS SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. 3.REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. WOOD: 1.GENERAL: DO NOT NOTCH OR DRILL JOISTS, BEAMS, OR LOAD BEARING STUDS WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER THROUGH THE ARCHITECT. DOUBLE UP JOISTS AND BLOCKING UNDER PARTITIONS. PROVIDE 2" (NOMINAL) SOLID BLOCKING AT SUPPORTS OF ALL JOISTS. UNLESS NOTED OTHERWISE ON PLANS/DETAILS PROVIDE 2x SOLID BLOCKING AT MID-HEIGHT OF BEARING STUD WALLS. ALL NAILING NOT NOTED SHALL BE ACCORDING TO IBC TABLE 2304.10.1. JOIST HANGERS AND OTHER MISC. FRAMING ANCHORS SHALL BE SIMPSON STRONG-TIE COMPANY, INC. OR OTHER MANUFACTURER WITH CURRENT ICC-ES APPROVAL. 2.SAWN LUMBER: FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) OR THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB). ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY. SAWN LUMBER SHALL HAVE THE FOLLOWING MINIMUM GRADE UNLESS NOTED OTHERWISE IN SCHEDULES: USE:MATERIAL: 2x4 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) 2x6 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) JOISTS, TOP PLATES AND ALL OTHER SAWN LUMBER DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) BEAMS AND POSTS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) LOCATION:NOMINAL THICKNESS: SPAN INDEX RATING: EDGE ATTACHMENT: FIELD ATTACHMENT: WALL 7 16" OR 12"24 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 7 16" OR 12"24 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 15 32" OR 12"32 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 19 32" OR 5 8"40 20 10d AT 6" O.C.10d AT 12" O.C. ROOF 23 32" OR 3 4"48 24 10d AT 6" O.C.10d AT 12" O.C. ROOF 7 8"60 32 10d AT 6" O.C.10d AT 12" O.C. FLOOR 3 4" T&G 48 24 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 7 8" T&G 60 32 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 118" T&G 60 48 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. 3.PLYWOOD: ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING CONFORMING TO STANDARD PS 1-95. LAY UP PLYWOOD WITH FACE GRAIN IN PERPENDICULAR TO SUPPORTS (ON ROOFS WHERE PLYWOOD IS LAID UP WITH FACE GRAIN PARALLEL TO SUPPORTS, USE A MINIMUM OF 5-PLY PLYWOOD, STAGGER JOINTS). ALL NAILING, COMMON NAILS. BLOCKING AT PANEL EDGES WHERE INDICATED ON PLANS. ALL PLYWOOD SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATING AND SHALL BE NAILED AS FOLLOWS UNLESS NOTED OTHERWISE ON THE PLANS: DEFERRED SUBMITTAL ITEMS: PREFABRICATED WOOD ROOF TRUSSES SHEET INDEX SHEET DESCRIPTION DETAILS S1.0 GENERAL STRUCTURAL NOTES --- S1.1 TYPICAL DETAILS T-SERIES S1.2 TYPICAL DETAILS T-SERIES S2.0 FOUNDATION PLAN --- S2.1 FLOOR FRAMING PLAN --- S2.2 ROOF FRAMING PLAN --- S3.0 FOUNDATION DETAILS 100 - SERIES S4.0 FRAMING DETAILS 200 - SERIES CAST IN PLACE CENTERLINE CENTERLINE OF BEAM CENTERLINE OF COLUMN CENTERLINE OF WALL CLEAR CONCRETE CONCRETE CONTROL JOINT CONCRETE SAWCUT JOINT CONCRETE MASONRY UNIT CONNECTION CONTINUOUS DEAD LOAD DOWN DRAWING(S) EQUAL EQUIPMENT EXPANSION JOINT EACH WAY FINISHED FLOOR FACE OF STEEL FACE OF WALL GAUGE GALVANIZED GENERAL STRUCTURAL NOTES CENTERLINE OF FOOTING FACE OF MEMBER EXPANSION BOLT EDGE OF SLAB DIAMETER GALV GSN DN. DWG(S) EQ EQUIP EXP. JT (E.J.) E.W. F.F. F.O.S. F.O.W. GA F.O.M. EXP. BOLT E.O.S. Ø OR DIA. C.I.P. C L C.L.B. C.L.C. C.L.W. CLR CONC C.C.J. C.S.J. C.M.U. CONN. CONT D L C.L.F. W/WITH W/O WITHOUT T.O.P. U.N.O. W.W.F. TYP VERT T.O.S. T.O.W. T.O.D. T.O.F. T.O.L. T.O.M. STD T.O.B. T L SLH SLV SIM SQ PSF PSI REINF PREFAB OPP P.C. PLF N.T.S. O.C. O.F.W. TOP OF FOOTING UNLESS NOTED OTHERWISE WELDED WIRE FABRIC TOP OF MASONRY TOP OF PLATE TOP OF STEEL TOP OF WALL TYPICAL VERTICAL STANDARD TOP OF BEAM TOP OF DECK TOP OF LEDGER TOTAL LOAD OUTSIDE FACE OF WALL PRECAST CONCRETE POUNDS PER LINEAR FOOT POUNDS PER SQUARE INCH SHORT LEG VERTICAL SHORT LEG HORIZONTAL REINFORCING SIMILAR SQUARE NOT TO SCALE ON CENTER OPPOSITE PREFABRICATED AGGREGATE BASE COURSE AIR CONDITIONER ABOVE FINISHED FLOOR ALTERNATE ANCHOR BOLT AT (MEASUREMENT) BEAM BOTTOM OF BEAM BOTTOM OF DECK BEARING BELOW FINISHED FLOOR BOTTOM OF FOOTING A.B.C. A/C A.F.F. ALT A.B. @ BM B.O.B. B.O.D. BRG B.F.F B.O.F. ABBREVIATIONS LBS (#) MFR('S) M.C.J. MECH N/A LLV LLH HORIZ K(KIP) L L LONG LEG VERTICAL MANUFACTURER('S) MASONRY CONTROL JOINT NOT APPLICABLE LONG LEG HORIZONTAL POUNDS MECHANICAL HORIZONTAL 1000 POUNDS LIVE LOAD EXISTING(E) MIN MINIMUM MAX MAXIMUM POUNDS PER SQUARE FOOT GLUED-LAMINATED BEAMGLB PFT PREFAB FLOOR TRUSSES PRT PREFAB ROOF TRUSSES I.F.W.INSIDE FACE OF WALL PT PRESSURE TREATED CONCRETE COLUMNC.C. RME ROOF MOUNTED EQUIPMENT SCREWS AT FLOOR SHEATHING SHALL BE #8 SCREWS AND SHALL PENETRATE AT LEAST 112" INTO THE SUPPORTING MEMBER. ALL FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING MEMBERS WITH AN APA AFG-01 QUALIFIED ADHESIVE. PLYWOOD ALTERNATE: AMERICAN PLYWOOD ASSOCIATION PERFORMANCE RATED SHEATHING MAY BE USED AS AN ALTERNATE TO PLYWOOD WITH PRIOR APPROVAL OF OWNER, ARCHITECT AND ROOFER. IT MAY NOT BE USED ON ROOFS WHERE BUILT-UP ROOF SYSTEM IS TO BE GUARANTEED BY ROOFER. RATED SHEATHING SHALL COMPLY WITH CURRENT ICC-ES REPORTS AND SHALL HAVE A SPAN RATING EQUIVALENT TO OR BETTER THAN THE PLYWOOD IT REPLACES. ATTACHMENT AND THICKNESS (WITHIN 132") SHALL BE THE SAME AS THE PLYWOOD IT REPLACES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4.NOMINAL 2x AND 3x DECKING. TONGUE AND GROOVE TYPE. MINIMUM Fb = 1,600 PSI, MINIMUM E = 1,300,000 PSI. INSTALL WITH TONGUES UP SLOPE ON PITCHED ROOFS, AND OUTWARD IN THE DIRECTION OF LAYING ON FLAT ROOFS. NAIL EACH PLANK WITH 16d TOENAIL (THRU THE TONGUE) AND 16d FACE NAIL AT EACH SUPPORT. DECK SHALL BE INSTALLED AS SIMPLE SPAN WITH ALL PLANKS BEARING ON TWO SUPPORTS. FOR REFERENCE AND/OR ADDITIONAL INFORMATION SEE AITC 117-2010. 5.GLUED-LAMINATED BEAMS (GLB): GLUED-LAMINATED BEAMS SHALL BE DOUGLAS FIR COMBINATION AT 24F-V4 AT SIMPLE SPAN BEAMS AND 24F-V8 AT MULTI-SPAN AND CANTILEVERED BEAMS WITH THE FOLLOWING MINIMUM PROPERTIES: FB = 2,400 PSI, FV = 190 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,800 KSI. ALL BEAMS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. BEAMS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. CAMBER AS SHOWN ON DRAWINGS. STANDARD CAMBER IS BASED ON A RADIUS OF CURVATURE OF 2000 FEET. 6.GLUED-LAMINATED COLUMNS: GLUED-LAMINATED COLUMNS SHALL BE DOUGLAS FIR COMBINATION 3 WITH THE FOLLOWING MINIMUM PROPERTIES: FBY = 2,100 PSI, FBX = 2000 PSI, FVY = 230 PSI, FVX = 265 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,900 KSI. ALL COLUMNS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. COLUMNS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. 7.LAMINATED VENEER LUMBER (LVL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LVLs SHALL BE: FB = 2,600 PSI, FV = 285 PSI, E = 2,000 KSI. 8.PARALLEL STRAND LUMBER (PSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR PSLs SHALL BE: FB = 2,900 PSI, FV = 290 PSI, E = 2,000 KSI. 9.LAMINATED STRAND LUMBER (LSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LSLs SHALL BE: FB = 2,325 PSI, FV = 310 PSI, E = 1,550 KSI. 10.SILL PLATES RESTING ON CONCRETE OR MASONRY SHALL BE OF TREATED FIR. SHEAR WALLS AND EXTERIOR WALL SILLS AT CONCRETE SLAB SHALL HAVE A MINIMUM OF (2) ANCHOR BOLTS PER PIECE. PROVIDE ANCHOR BOLT AT 9" MAXIMUM, 4" MINIMUM FROM THE END OF EACH PIECE AT SPLICE OR END OF WALL. MAXIMUM ANCHOR BOLT SPACING SHALL BE 72" ON CENTER UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. ALL ANCHOR BOLTS (OTHER THAN BOLTS FOR HOLDOWNS) SHALL EMBED 7" INTO CONCRETE. ANCHOR BOLTS FOR HOLDOWNS SHALL NOT BE CONSIDERED AS PART OF REQUIRED ANCHOR BOLTS ON SHEAR WALLS. ALL EXTERIOR WALLS SHALL BE SECURED WITH MINIMUM ANCHOR BOLTS. INTERIOR WALLS MAY BE SECURED TO CONCRETE WITH EITHER ANCHOR BOLTS OR POWER DRIVEN SHOT PINS UNLESS NOTED OTHERWISE ON PLANS. 11.BOLTING: ALL BOLTS IN WOOD CONNECTIONS SHALL CONFORM TO ASTM A307. BOLTS SHALL BE INSTALLED IN HOLES BORED WITH A BIT 116" LARGER THAN THE Ø (DIAMETER) OF THE BOLT. BOLTS AND NUTS SEATING ON WOOD SHALL HAVE CUT STEEL WASHERS UNDER HEADS AND NUTS. NICK THREADS TO PREVENT LOOSENING. 12.PREFABRICATED WOOD TRUSSES: PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. WHERE UNINHABITABLE ATTIC SPACE CAN BE USED FOR STORAGE, A 20 PSF LIVE LOAD ON THE BOTTOM CHORD SHALL BE INCLUDED IN THE ANALYSIS. BRIDGING SIZE AND SPACING BY TRUSS MANUFACTURER UNLESS NOTED OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER FOR REVIEW PRIOR TO MANUFACTURE FOR BOTH ROOF AND FLOOR TRUSSES WHEN USED. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICC-ES APPROVAL. ADDITIONAL TRUSSES SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. PER IBC SECTION 2303.4 AND TPI-1: EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS, THE DESIGN LOADS, AND THE TRUSS SPACING - WITHIN TWO FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD. PREFABRICATED WOOD/STEEL WEB JOIST/PURLINS (TJI/TJL SERIES OR EQUAL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST EDITION ICC-ES REPORT. CONNECTIONS AND BEARING MATERIAL TO BE DESIGNED AND FURNISHED BY JOIST FABRICATOR. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED STRUCTURAL ENGINEER FOR REVIEW PRIOR TO MANUFACTURE. ADDITIONAL JOISTS SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. KEYNOTES: 1.FINISHED GRADE WHERE OCCURS 2.DO NOT EXCAVATE A TRENCH CLOSER THAN A 45 DEGREE ANGLE TO BELOW BOTTOM FOOTING OR FOUNDATION 3.BOTTOM OF CONCRETE FOOTING 4.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPE OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 1 1 1 2 3 4 FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T1 TRENCH PARALLEL TO CONTINUOUS STRIP FOOTING TD-CF01 NO SCALE KEYNOTES: 1.CONCRETE FOOTING 2.SLEEVE - PROVIDE 1 2" MINIMUM CLEARANCE AROUND PIPE OR CONDUIT 3.PIPE OR CONDUIT 4.CONCRETE FILL TO BE PLACED BEFORE FOOTING IS POURED - FORM SAME AS FOOTING AND POUR FULL WIDTH OF PIPE TRENCH 5.STEM WALL NOTE: A.NO PIPE SHALL PASS THRU FOOTING OR UNDER COLUMN FOOTINGS. FOR TRENCHES GREATER THAN 3'-6" BELOW BOTTOM OF FOOTING, SEE PIPE PASSING BELOW WALL FOOTING DETAIL. 1 2 3 4 5 5 4 2 1 3 T2 PIPE PASSING UNDER WALL FOOTING IN SHALLOW TRENCH TD-CF02 NO SCALE 6" M I N 8" M I N 3' - 0 " M A X 8" MIN A SECTIONA KEYNOTES: 1.STEM WALL 2.CONCRETE FOOTING 3.1'-6" MAXIMUM - WHERE TRENCH EXCEEDS 1'-6" NOTIFY STRUCTURAL ENGINEER PRIOR TO PLACEMENT OF FOOTINGS 4.BACKFILL AND RECOMPACT TRENCH PER SOILS REPORT AND SPECIFICATIONS 5.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPES OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 1 5 4 3 2 3' - 1 " O R G R E A T E R FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T3 PIPE PASSING BELOW FOOTING IN DEEP TRENCH TD-CF03 NO SCALE KEYNOTES: 1.SLOPED FINISH GRADE 2.MINIMUM FOOTING DEPTH PER G.S.N. - 12" MINIMUM 3.DEEPEN FOOTING AS REQUIRED TO ACCOUNT FOR SLOPED GRADE 4.CONCRETE FOOTING NOTE: A.FOR ADDITIONAL INFORMATION, SEE PLANS AND DETAILS 1 4 3 2 5'-0" T4 TYPICAL DETAIL FOR FOUNDATION EMBEDMENT TD_CF04 NO SCALE KEYNOTES: 1.CORNER DOWELS TO MATCH HORIZONTAL REINFORCEMENT 2.CONCRETE WALL WITH REINFORCEMENT 18" MIN LAP SPLICE (TYP) T5 TYPICAL CONCRETE CORNER TD_CF05 NO SCALE 2 1 KEYNOTES: 1.CONCRETE SLAB ON GRADE 2.CONT KEYED JOINT 3.SAWCUT 18" WIDE x 14 SLAB THICKNESS IN DEPTH - CUT SHALL BE MADE SOON ENOUGH TO PREVENT SHRINKAGE CRACKING, BUT NOT SO SOON AS TO CAUSE SPALLING OF THE CONCRETE WHILE SAWING. WORK MUST BE COMPLETE WITHIN 16 HOURS OF CONCRETE PLACEMENT. NOTE: A.KEYED JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING PLACEMENT UNLESS SPECIFICALLY NOTED ON THE PLANS. B."TOOL WET JOINT", "ZIP STRIP", ETC SHALL MATCH SAWCUT REQUIREMENTS 1 2 3 1 12"6"6"12" X SAWCUT JOINT X KEYED JOINT T6 CONTROL JOINTS IN CONCRETE SLAB ON GRADE TD_CF07 NO SCALE 6 MIN BAR OFFSET BAR CLEARANCE SPLICE DETAIL BEND & HOOK DETAILS COLUMN TIES BEAM STIRRUPS "d" 45° "d" "d" 1 2 4 5 6 10 9 8 7 3 1 5 5 9 10 8 KEYNOTES: 1.LAP - SEE G.S.N. 2.MAXIMUM 15 LAP BUT NOT MORE THAN 6" 3.WIRE TIES 4.1d (1" MINIMUM) 5.RADIUS = 3d FOR BARS NOT OVER #8; 4d FOR #9, #10, AND #1 BARS; 5d FOR #14 AND #18 BARS, 5d FOR ALL GRADE 40 BARS WITH 180 DEGREE HOOK 6.4D (4" MINIMUM) 7.12d (90 DEGREE HOOK) 8.6d (4" MINIMUM) 9.135 DEGREE BEND 10.BEND AROUND 112" PIN FOR #3 BARS. BEND AROUND 2" PIN FOR #4 BARS. BEND AROUND 21 2" PIN FOR #5 BARS. T7 TYPICAL REINFORCING DETAILS TD_CF10 NO SCALE NOTES: 1.TOP BARS ARE ANY HORIZONTAL BARS PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. 2.UNLESS NOTED OTHERWISE, LAP SPLICES IN CONCRETE BEAMS, SLABS AND WALLS SHALL BE CLASS "B" TENSION LAP SPLICES. BAR SIZE CLASS B TENSION SPLICE LENGTHS f'c = 3,000 PSI f'c = 4,000 PSI f'c = 5,000 PSI HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS #3 12"12"12"12"12"12" #4 19"15"17"13"15"12" #5 29"23"26"20"23"18" #6 32"25"28"21"25"19" #7 54"41"47"36"42"32" #8 70"54"61"47"54"42" #9 89"68"77"59"69"53" #10 112"87"97"75"87"67" T8 STEEL REINFORCING LAP SPLICES IN CONCRETE TD_CF14 NO SCALE KEYNOTES: 1.NAILS BETWEEN SPLICE LOCATION PER SCHEDULE - STAGGERED 2.DBL 2x TOP PLATE 3.WOOD STUD WALL, SEE PLAN 4.SPLICE OVER STUD 5.SIMPSON ST6224 OR MSTC40 STRAP AT LOCATIONS WHERE PLATES CAN NOT BE SPLICED NOTE: A.DO NOT SPLICE TOP PLATES WITHIN 6'-0" OF ENDS OF PLYWOOD SHEARWALLS. THIS DETAIL REQUIRED AT ALL EXTERIOR WALLS AND OVER SHEARWALLS - NOT REQUIRED AT INTERIOR NON-SHEARWALLS. (30) 16d (24) 16dLESS THAN 20' OVER 20' 4'-0" 6'-0" LENGTH OF WALL (BETWEEN CORNERS)SPLICE LENGTH NAILS ALONGSPLICE LENGTH MINIMUM 1 2 4 5 3 23 SPLICE LENGTH PER SCHEDULE T9 ELEVATION - TYPICAL TOP PLATE SPLICE TD_WF01 NO SCALE KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.WOOD HEADER 3.KING STUD(S) PER PLAN 4.(2) 16d NAILS AT 2" O.C. 5.16d NAILS AT 12" O.C. 6.TRIMMER STUD(S) PER PLAN 2 6 3 1 5 4 5 T11 TYPICAL HEADER CONNECTION TD_WF02 NO SCALE KEYNOTES: 1.DBL TOP PLATE, SEE PLAN 2.WOOD STUD WALL, SEE PLAN 3.PLYWOOD SHEATHING 4.WOOD POST ABOVE 5.WOOD TRUSS OR JOIST 6.SOLID BLOCKING BETWEEN FLOORS, MATCH BEARING WITH OF POST ABOVE, MINIMUM 7.SIMPSON A35 CLIP EACH SIDE OF SOLID BLOCKING, WHERE POST ABOVE IS MORE THAN (2) STUDS, OTHERWISE ATTACH TO TOP PLATE WITH (2) 16d TOE-NAILS AT EACH BLOCK 8.WOOD POST BELOW 2 1 5 6 7 8 3 4 2 T12 SOLID BLOCKING BETWEEN FLOORS TD_WF04 NO SCALE 3 4 2 2 1 8 7 6 5 5 KEYNOTES: 1.SOLID BLOCKING TO BE TIGHT AGAINST PLYWOOD 2.PREFAB WOOD TRUSS OR WOOD JOIST 3.TOP OF WOOD PLATE OR BEAM AS OCCURS 4.PLYWOOD SHEATHING 5.EDGE NAILING NOTE: A.FOR CONSTRUCTION BELOW BLOCKING, SEE PLAN AND DETAILS. BLOCKING IS CONTINUOUS B.INDIVIDUAL SHEAR BLOCKS MAY BE OMITTED EVERY 5TH BLOCK DEPTH X 2"6" 2.5"8" 10" 12" 3" 3" X X2X X SOLID 2x BLOCKING WITH FIELD CUT VENTILATION VENTILATION OPENINGS TYPICAL SOLID BLOCKING DE P T H TYPICAL SOLID BLOCKING WITH PREFAB VENTILATION X T13 ELEVATION - TYPICAL SOLID 2x BLOCKING TD_WF08 NO SCALE 4 5 2 31 5 4 2 31 5 5 4 2 31 CONNECTION TYPE JOIST OR TRUSS BEARING ON SILL OR GIRDER BRIDGING TO JOIST SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL TOP PLATE TO STUD DOUBLE STUDS, FACE NAIL DOUBLE TOP PLATES CONTINUOUS HEADER TO STUD CEILING JOISTS, LAPS OVER PARTITIONS CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL RAFTER OR TRUSS TO PLATE BUILT-UP CORNER STUDS TOENAIL (4)-8d COMMON (2 1/2" x 0.131") NAILING (3)-8d COMMON (2 1/2" x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL EACH END(2)-3"x 0.131" NAILS (Gun Nail) (2)-3"x 14 GAUGE STAPLES 16d (3 1/2"x 0.135") AT 16" O.C. FACE NAIL 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES SOLE PLATE TO STUD END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES FACE NAIL 16d (3 1/2"x 0.135") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 8" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. FACE NAIL 16d (3 1/2"x 0.135") AT 16" O.C. 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 12" O.C. DOUBLE TOP PLATES - FACE NAIL (8)-16d COMMON (3 1/2"x 0.162") (12)-3"x 0.131" NAILS (Gun Nail) (12)-3"x 14 GAUGE STAPLES LAP SPLICE RIM JOIST TO TOP PLATE 8d (2 1/2"x 0.131") AT 6" O.C. 3"x 14 GAUGE STAPLES AT 6" O.C. 3"x 0.131" NAILS (Gun Nail) AT 6" O.C. BLOCKING BETWEEN JOISTS OR RAFTERS TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES AND TOP PLATE TOENAIL TOP PLATES, LAPS AND INTERSECTIONS FACE NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES CONTINUOUS HEADER, TWO PIECES 16d COMMON (3 1/2"x 0.162") FACE NAIL AT 16" O.C. ALONG EDGES CEILING JOISTS TO PLATE TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (5)-3"x 0.131" NAILS (Gun Nail) (5)-3"x 14 GAUGE STAPLES FACE NAIL (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES FACE NAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL TOENAIL 16d COM.(3 1/2"x 0.162") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 16" O.C. 3"x 0.131" NAILS (Gun Nail) AT 16" O.C.FACE NAIL (2)-8d COMMON (2 1/2" x 0.131") USE- SIMPSON A35 AT 48" O.C.-NA- SIMPSON A35 AT EVERY OTHER BLOCK -NA- NOTE: A.MINIMUM NAILING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES B.NAILING NOT NOTED ON THESE PLANS OR DETAILS SHALL BE PER I.B.C. TABLE 2304.10.1 T10 MINIMUM NAILING SCHEDULE - UNLESS NOTED OTHERWISE TD_WF16 NO SCALE PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 9/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-320 KEYNOTES: 1.EDGE NAILING 2.PREFAB WOOD TRUSS, TRUSS MANUFACTURER SHALL PROVIDE VERTICAL WEB TO MATCH LOCATION OF SHEAR PANEL 3.7 16" PLYWOOD SHEAR PANEL WITH 8d AT 6" O.C. AT PANEL EDGES AND 8d AT 12" O.C. AT INTERMEDIATE SUPPORTS 4.PLYWOOD SHEATHING AS OCCURS 5.2x4 AT 4-SIDES 6.TOP OF WOOD PLATE OR BEAM AS OCCURS 7.PREFAB BLOCKING PER TRUSS MANUFACTURER, IN-PLANE SHEAR CAPACITY TO BE 200# NOTE: A.FOR CONSTRUCTION BELOW PANEL, SEE PLAN AND DETAILS. BLOCKING IS CONTINUOUS B.INDIVIDUAL SHEAR PANEL BLOCKS MAY BE PENETRATED OR OMITTED FOR PASSAGE OF HVAC DUCTS PLYWOOD SHEAR PANEL ALTERNATE PREFAB BLOCKING T14 ELEVATION - TYPICAL PLYWOOD SHEAR PANEL BLOCKING TD_WF09 NO SCALE 4 11 33 55 2 4 2 11 7 26 KEYNOTES: 1.SHEATHING MATERIAL 2.DOUBLE STUDS AT EACH END OF SHEARWALL, EDGE NAIL ALONG DOUBLE STUDS 3.FULL HEIGHT WOOD STUDS 4.2ND FLOOR LINE 5.SIMPSON STRAP TYPE HOLDOWN 6.MIDHEIGHT BLOCKING AND EDGE NAILING REQUIRED AT PLYWOOD SHEET EDGES 7.SIMPSON HD TYPE HOLDOWN 8.1ST FLOOR LINE 9.BOTTOM PLATE ATTACHMENT 10.CONT 2x PT SOLE PLATE 11.SOLE PLATE ATTACHMENT 1 3 2 5 11 7 6 8 5 4 9 3 T15 ELEVATION - TYPICAL 2-STORY SHEARWALL TD_WF12 NO SCALE 10 T17 STRAP TYPE HOLDOWNS / SHEARWALL END POSTS, PLAN VIEW - HOLDOWN LOCATIONS TD_WF14 NO SCALE NOTE: A.ALL CONDITIONS MAY NOT BE SHOWN. FOR CONDITIONS NOT SHOWN, USE THESE DETAILS AS A GUIDE. B.SOME LARGER HOLDOWNS REQUIRE 6x6 POSTS, SEE PLANS AND SCHEDULES. C.WHERE MULTIPLE TRIMMER STUDS OR KING STUDS OCCUR, MAKE ADJUSTMENTS AS REQUIRED. KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.SHEARWALL SHEATHING, SEE PLAN 3.STRAP TYPE HOLDOWN 4.EDGE OF FOUNDATION 5.SHEARWALL END POST (3 STUDS) 6.SHEARWALL END POSTS (2 STUDS) 7.SHEARWALL EDGE NAILING 8.TRIMMER STUD TO SUPPORT HEADER 9.BLOCK TO SUPPORT WINDOW SILL 10.6x6 WOOD POST 11.(25) - SIMPSON SDS 1 4"x412" LONG WOOD SCREWS, STAGGERED 12.(25) - SIMPSON SDS 1 4"x6" LONG WOOD SCREWS, STAGGERED "STRAP" TYPE HOLDOWN WINDOW JAMB "STRAP" TYPE HOLDOWN DOOR JAMB OR WALL END (1) SHEARWALL (1) STRAP HOLDOWN AT EXTERIOR CORNER (2) SHEARWALLS (1) STRAP HOLDOWN AT EXTERIOR CORNER (2) SHEARWALLS (1) STRAP HOLDOWN AT RE-ENTRANT CORNER (1) SHEARWALL (1) STRAP HOLDOWN AT RE-ENTRANT CORNER WINDOW OPENING DOOR OPENING 3" 3" 3"3" 4 2 1 3 3 7 2 2 1 1 9 3 1 6 8 4 3 12 4 23 7 2 11 10 23 1 5 5 6 5 5 NOTE: A.MINIMUM STAPLING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES 8d COMMON AT 12" O.C. 16 GA STAPLE AT 12" O.C. ALTERNATE FASTENER SCHEDULE ALTERNATE FASTENERSPECIFIED FASTENER 8d COMMON AT 6" O.C. 8d COMMON AT 4" O.C. 15 GA STAPLE AT 12" O.C. 14 GA STAPLE AT 12" O.C. 13 GA STAPLE AT 12" O.C. 16 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 3" O.C. 16 GA STAPLE AT 2.5" O.C. 15 GA STAPLE AT 2" O.C. 14 GA STAPLE AT 3" O.C. 13 GA STAPLE AT 4" O.C. 8d COMMON AT 3" O.C. MATERIAL: 7/16" SHEARWALL OR ROOF SHEATHING NOTES: 1.STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7 16" INCH OUTSIDE DIMENSION. AND INSTALLED WITH CROWN PARALLEL TO THE LONG DIMENSION OF FRAMING MEMBER. 2.FRAMING SHALL BE 3x OR WIDER WHEN NAIL SPACING IS LESS THAN 3 INCHES ON CENTER. 3.ALL STAPLES SHALL HAVE 112" LONG LEGS MINIMUM. 4.STAPLE SIZES AND SPACING PER REPORT NO. ICC-ESR-1539 T18 ALTERNATE SHEATHING STAPLE OPTION TD_WF17 NO SCALE T16 TYPICAL WOOD TRUSS AT NON-BEARING WALL TD_WF23 NO SCALE KEYNOTES: 1.WOOD TRUSS 2.HTC4 CLIP AT WALL ENDS AND AT 48" O.C. (MAX) REMAINDER 3.DBL TOP PLATE AT NON-BEARING WALL NOTE: A.NAILS SHOULD NOT BE DRIVEN COMPLETELY FLUSH AGAINST THE CONNECTOR AT THE TRUSS TO ALLOW VERTICAL TRUSS MOVEMENT, ALLOW 116" GAP BETWEEN NAIL HEAD AND TRUSS CLIP B.ARCH TO PROVIDE FINISH TO ALLOW FOR 3 4" VERTICAL MOVEMENT OF TRUSS 1 2 3 3 4 " G A P M I N 5 4 KEYNOTES: 1.2x4 FRAMING AT EACH FRAMING MEMBER, POCKETED THROUGH SHEATHING AND ATTACHED W/ (4) 16d NAILS 2.CONT 2x W/ (2) 16d NAILS 3.2x4 VERTICAL W/ (3) 16d NAILS EACH END 4.WALL SHEATHING W/ 8d NAILS AT 4" O.C. AT ALL EDGES 5.2x4 W/ LUS24 HANGER 6.CONT 2x4 LEDGER W/ (2) 16d NAILS AT EACH STUD T19 TYPICAL EYEBROW FRAMING DETAIL NO SCALE 6 3 1 2 2 4 4 1'-0" MAX PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 9/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-320 45 ' - 7 1 2" 3' - 0 " 4' - 1 1 1 2" 22 ' - 9 " 14 ' - 9 " 3' - 2 " 46'-9" 6'-21 2"14'-2"6'-0"14'-2"6'-21 2" 1'-4"1'-4" 44'-1" 13'-81 4"11'-03 4"19'-4" 21'-81 2"22'-41 2" 4" CONCRETE SLAB ON GRADE W/ #3 AT 24" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = 100'-0" CONCRETE SLAB ON GRADE WF18 / W1 WF 2 4 WF18 / W1 WF18 / W1 WF18 / W1 WF18 / W1 WF18 / W1WF18 / W1 WF18 / W1 WF 1 8 / W 1 WF 1 8 / W 1 WF 1 8 / W 1 WF 1 8 / W 1 A A A A A A 102 TYP 101 TYP 101 TYP 101 TYP 101103 103 TYP 101 TYP 101102 TYP 101 TYP 101 102 WF 1 8 WF 1 8 104 104 5 5 5 6. 5 5 5 5 6.6. A A A A A A A A 102 F36 F42 WF 2 4 WF 2 4 WF 2 4 WF24 WF24 SCALE: FOUNDATION PLAN 1/4" = 1'-0" PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 9/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-320 WALL (W) SCHEDULE MARK THICKNESS AND TYPE VERTICAL REINFORCING HORIZONTAL REINFORCING REMARKS W1 8" CONCRETE #4 AT 18" O.C.#4 AT 12" O.C.--- FOOTING SCHEDULE NOTES: 1. FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. 2. FOR MINIMUM CLEARANCE (CLR) OF REINFORCING, SEE GENERAL STRUCTURAL NOTES (GSN). MARK LENGTH WIDTH THICKN ESS FOOTING REINFORCING REMARKS F36 36"36"10"(4) #4 BARS EACH WAY, BOTTOM --- F42 42"42"10"(5) #4 BARS EACH WAY, BOTTOM --- WF18 CONT 18"10"(2) #4 CONT BOTTOM WF24 CONT 24"10"(2) #4 CONT BOTTOM MONO POUR W/ SLAB STRIP FOOTING A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.THE DEPTH OF FOOTING DIMENSION INDICATED IN THE G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS. D. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. E. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. F. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. G. , , - AS SHOWN ON PLAN INDICATES A SHEARWALL HOLDOWN. SEE HOLDOWN SCHEDULES AND DETAILS FOR ADDITIONAL INFORMATION. H.W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. I.WF18, WF24, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS WALL FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. J.F36, F48, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. K.TYPICAL TOP OF CONCRETE WALL = 100'-0" L.TYPICAL TOP OF EXTERIOR FOOTING = 97'-0" M.TYPICAL TOP OF INTERIOR FOOTING = 99'-8" N.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. O.PROVIDE CONTINUOUS BEARING FOR ALL POSTS AND BUILT-UP STUDS TO THE FOUNDATION PER TYPICAL "SOLID BLOCKING BETWEEN FLOORS" DETAIL. P.ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. Q.FOR SIDEWALK AND LANDING LOCATIONS, SEE ARCHITECTURAL DRAWINGS. FOUNDATION PLAN NOTES 5 6.7 A B SHEARWALL HOLDOWN SCHEDULE MARK HOLDOWN SHEARWALL END POST UNO ON PLAN ALTERNATE HOLDOWN SIMPSON STHD10 (2) 2x STUDS N/AA SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 32" O.C. WOOD:16d STAGGERED AT 4" O.C. 5 6. B1 B2 B2 B1 B1 B3 B1 B1 B1 WJ1 7/16" APA RATED ROOF SHEATHING W/ 8d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. TYPICAL ROOF SHEATHING: TYPICAL FLOOR SHEATHING: 3/4" APA RATED FLOOR SHEATHING W/ 10d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. B4 B4 OPEN 201 201 202 202 204 206 206 202 202 18 " D E E P F L O O R T R U S S E S AT 1 6 " O . C . 18 " D E E P F L O O R T R U S S E S AT 1 6 " O . C . B3B3 5 5 5 5 5 5 5 6. 203 203 B1 B1 B1 B1 6. WJ1 B1 201 SIM 206 212 211 1 6 5 P1 P1 P2P2 P2P2 B5 6. P1 GT P1 GT 44 2 212 211 P1P1 GTGT 1 3 7 7 2 SCALE: FLOOR FRAMING PLAN 1/4" = 1'-0" PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 9/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 32" O.C. WOOD:16d STAGGERED AT 4" O.C. 5 6. BEAM (B) SCHEDULE MARK SIZE B1 (2) 2x6 OR 4x6 OR (2) 13 4x512 LVL B2 (2) 2x8 OR 4x8 OR (2) 13 4x512 LVL B3 (2) 2x10 OR 4x10 OR (2) 13 4x714 LVL B4 (3) 2x10 OR 6x10 OR (3) 13 4x714 LVL B5 (3) 13 4x912 LVL FLOOR FRAMING PLAN NOTES A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. D.TYPICAL BEARING WALL FRAMING SHALL BE 2x6 STUDS AT 16" O.C. UNO. E.PROVIDE TRIMMER STUDS (TS) AND KING STUDS (KS) AT OPENINGS AS FOLLOWS, U.N.O.: OPENINGS 6'-0" OR LESS, (1) TS & (1) KS, OPENINGS 6'-1" TO 9'-0", (1) TS & (2) KS, 9'-1" TO 12-0", (2) TS & (3) KS. FOR ATTACHMENT, SEE "TYPICAL HEADER CONNECTION" DETAIL. F. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. G. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. H. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. I.B1, B2, ETC. - AS SHOWN ON PLAN INDICATES A BEAM OR HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION. J.WJ1, WJ2, ETC. - AS SHOWN ON PLAN INDICATES A WOOD JOIST. SEE WOOD JOIST SCHEDULE FOR ADDITIONAL INFORMATION. K.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. L.PROVIDE CONTINUOUS BEARING FOR ALL POSTS AND BUILT-UP STUDS TO THE FOUNDATION PER TYPICAL "SOLID BLOCKING BETWEEN FLOORS" DETAIL. M.FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. N.ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. 5 6.7 WOOD JOIST ( ) SCHEDULE MARK JOIST FACE MOUNT HANGER TOP FLANGE HANGER WJ1 2x6 AT 16" O.C.LUS26 LB26 WJ JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-320 1.ATTACH JOISTS TO WALL WITH LEDGER AND HANGERS. LEDGER SHALL BE A CONTINUOUS 2x6 W/ (2) SDWS22400DB SCREWS AT EACH STUD 2.PRE-MANUFACTURED AWNING BY OTHERS, SEE DETAIL 206 FOR AWNING ATTACHMENT TO WALL FRAMING REQUIREMENTS 3.DOUBLE JOIST AT EDGE AND ATTACH DOUBLE JOIST TO LEDGER WITH HUC26-2 4.GIRDER TRUSS SHALL BE DESIGNED TO SUPPORT THE STAIRS. APPLY A POINT LOAD OF 1,100 LBS (ASD) TO THE GIRDER TRUSS (DL = 200 LBS, LL = 900 LBS) 5.PARTY WALL FRAME SHALL BE DOUBLE STUD WALL EACH FRAMED WITH 2x4 AT 16" O.C. 6.BEARING WALL FRAMING SHALL BE 2x4 AT 16" O.C., ALIGN A STUD W/ EACH FLOOR TRUSS 7.AT POP-OUT FRAMING, ATTACH END STUD TO MAIN WALL FRAMING WITH #10x4" LONG SCREWS AT 6" O.C.. SHEATH ENTIRE EXTERIOR OF THE POP-OUT AND PROVIDE NAILING ACCORDING TO A "6." SHEARWALL PLAN KEYNOTESX POST (P) SCHEDULE NOTES: 1. FOR CONNECTIONS AT EITHER END OF POST, SEE DETAILS. 2. UNO, SEE GENERAL STRUCTURAL NOTES (GSN) FOR LUMBER SPECIES AND GRADE. MARK SIZE SPECIES AND GRADE CONNECTION P1 (2) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS P2 (3) 2x4 DOUG FIR NO. 2 SEE TYPICAL DETAILS 17 4 ' - 1 0 " 2X6 Exterior Wall 185 LF STUDS = 184 Ea King/Trimmers = 56 EA HEADER- 244 RLLF 2x6 TOP PLATE = 402 RLLF 2x6 BOTTOM PLATE = 201 RLLF 2x6 PRESSURE TREATED Sheathing whole building ext walls = 222 Ea 7/16 RIM JOIST = 185 LF U SHAPE POPOUT = 560 LF 2X6 47 ' - 5 3 / 4 " 5' - 2 1 / 4 " 5'-3" 5' - 4 1 / 2 " 2'-7" 29 ' - 1 " 16'-1/4" 4 ' - 1 1 1 / 2 " 11'-3/4" 19/32" APA RATED ROOF SHEATHING W/ 10d COMMON NAILS AT 6" O.C. AT PANEL EDGES / BOUNDARY AND AT 12" O.C. IN THE FIELD. TYPICAL ROOF SHEATHING: 5 5 5 5 5 5 5 5 5 5 209 208 208 209 209 208 208 207 PR E F A B W O O D T R U S S AT 2 4 " O . C . P1 B1 B1 B1 B1 B2B2 B1 B1 B1 B1 B1 B1 B1 P1 210 GT P2P2 GT (2) KS(2) KS(2) KS(2) KS(2) KS(2) KS (2) KS(2) KS(2) KS(2) KS (2) KS(2) KS 2 2 1 SCALE: ROOF FRAMING PLAN 1/4" = 1'-0" PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 9/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING POST (P) SCHEDULE NOTES: 1. FOR CONNECTIONS AT EITHER END OF POST, SEE DETAILS. 2. UNO, SEE GENERAL STRUCTURAL NOTES (GSN) FOR LUMBER SPECIES AND GRADE. MARK SIZE SPECIES AND GRADE CONNECTION P1 (2) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS P2 (3) 2x4 DOUG FIR NO. 2 SEE TYPICAL DETAILS SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 4" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 24" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 32" O.C. WOOD:16d STAGGERED AT 4" O.C. 5 6. BEAM (B) SCHEDULE MARK SIZE B1 (2) 2x6 OR 4x6 OR (2) 13 4x512 LVL B2 (2) 2x8 OR 4x8 OR (2) 13 4x512 LVL B3 (2) 2x10 OR 4x10 OR (2) 13 4x714 LVL B4 (3) 2x10 OR 6x10 OR (3) 13 4x714 LVL B5 (3) 13 4x912 LVL ROOF FRAMING PLAN NOTES A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. D.TYPICAL BEARING WALL FRAMING SHALL BE 2x6 STUDS AT 16" O.C. U.N.O.. E.PROVIDE TRIMMER STUDS (TS) AND KING STUDS (KS) AT OPENINGS AS FOLLOWS, U.N.O.: OPENINGS 6'-0" OR LESS, (1) TS & (1) KS, OPENINGS 6'-1" TO 9'-0", (1) TS & (2) KS, 9'-1" TO 12-0", (2) TS & (3) KS. FOR ATTACHMENT, SEE "TYPICAL HEADER CONNECTION" DETAIL. F. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. G. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. H. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. I.B1, B2, ETC. - AS SHOWN ON PLAN INDICATES A BEAM OR HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION. J.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. K.TIE EACH ROOF TRUSS AT BEARING LOCATIONS WITH (1) H2.5A OR (1) H1 CLIP, AND EACH GIRDER TRUSS WITH (2) H2.5A CLIPS, U.N.O.. L.TIE EACH ROOF JOIST AT BEARING LOCATIONS WITH (1) H2.5A CLIP, U.N.O.. M.PROVIDE BUILT-UP 2x POSTS BELOW EACH GIRDER TRUSS, MATCH GIRDER TRUSS WIDTH, U.N.O.. N.FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. O.ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, U.N.O.. 5 6.7 JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-320 1.PARTY WALL FRAME SHALL BE DOUBLE STUD WALL EACH FRAMED WITH 2x4 AT 16" O.C. 2.ARCHITECTURAL EYEBROW, SEE TYPICAL EYEBROW FRAMING DETAIL FOR ATTACHMENT AND SEE ARCH DRAWINGS FOR DIMENSIONS PLAN KEYNOTESX 104 WOOD STUD WALL AT FOUNDATION NO SCALE KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ O.145"Ø MIN SHOT PIN AT 32" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE FOOTING, SEE PLAN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 3" CLR 3" CL R 5 1 2 4 3 3" CLR 3" CL R 5 1 2 4 3 A OPTION B OPTION 103 WOOD STUD WALL AT FOUNDATION NO SCALE 3" CLR 3" CL R 5 1 2 4 3 3" CLR. 3" CL R . 5 4 3 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ 5 8"Ø x 5" LONG TITEN HD ANCHORS AT 48" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE FOOTING, SEE PLAN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN A OPTION B OPTION 101 WOOD STUD WALL AT FOUNDATION CW_S103 NO SCALE 3" CLR 3" CL R 8 10 7 9 6 8 1 2 5 4 3 8" MI N KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x PT SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 9.EDGE NAILING, SEE SHEARWALL SCHEDULE 10.WALL SHEATHING AS OCCURS, SEE PLAN NOTES: A.WATERPROOF ANY EXTERIOR WOOD FRAMING WITHIN 8" OF GRADE PER ARCH DRAWINGS 102 CONCRETE SLAB AT FOUNDATION CW_S104 NO SCALE 3" CLR 3" CL R 8 7 6 8 5 4 3 1 2 KEYNOTES: 1.WALL BEYOND, SEE PLAN 2.#4 BENT DOWEL AT 18" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 18" 18" 1 2 1 2 1 2 PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 9/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-320 KEYNOTES: 1.WOOD TRUSS, SEE PLAN 2.2x4 x 6'-0" LONG AT 48" O.C. W/ (2) 16d NAILS AT EACH TRUSS 3.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.WOOD STUD WALL, SEE PLAN 5.WALL SHEATHING AS OCCURS, SEE PLAN 6.EDGE NAILING, SEE SHEARWALL SCHEDULE 7.WOOD TRUSS W/ 16d NAILS AT 4" O.C., SEE PLAN 8.BOUNDARY NAILING, SEE PLAN 9.CONT DBL 2x BOTTOM PLATE W/ ATTACHMENT, SEE SHEARWALL SCHEDULE 10.FLOOR SHEATHING, SEE PLAN 11.GYP-CRETE, SEE ARCH 201 WOOD TRUSS AT WOOD STUD WALL NO SCALE 1 3 4 6 5 8 7 4 9 10 A 2 6 NOTES: A.EXTEND WALL SHEATHING PAST DBL TOP PLATE NO WALL SHEATHING SPLICE BETWEEN DBL TOP PLATE AND BOTTOM PLATE 7 KEYNOTES: 1.WOOD TRUSS W/ (2) 16d NAILS, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.CONT 2x8 RIBBON BOARD TO RECEIVE EDGE NAILING 6.EDGE NAILING, SEE SHEARWALL SCHEDULE 7.BOUNDARY NAILING, SEE PLAN 8.CONT DBL 2x BOTTOM PLATE W/ ATTACHMENT, SEE SHEARWALL SCHEDULE 9.FLOOR SHEATHING, SEE PLAN 10.GYP-CRETE, SEE ARCH 202 WOOD TRUSS AT WOOD STUD WALL NO SCALE 1 2 3 6 6 4 7 5 3 9 A NOTES: A.EXTEND WALL SHEATHING PAST DBL TOP PLATE NO WALL SHEATHING SPLICE BETWEEN DBL TOP PLATE AND BOTTOM PLATE 6 KEYNOTES: 1.WOOD TRUSS W/ (2) 16d NAILS, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.GYP-CRETE, SEE ARCH 5.BOUNDARY NAILING, SEE PLAN 6.FULL-HEIGHT BLOCKING W/ A35 CLIP BETWEEN EACH TRUSS 7.FLOOR SHEATHING, SEE PLAN 203 WOOD TRUSS AT WOOD STUD WALL NO SCALE 1 3 2 6 75 204 WOOD TRUSS AT WOOD STUD WALL NO SCALE KEYNOTES: 1.WOOD TRUSS W/ (2) 16d NAILS, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.112" GYPCRETE, SEE ARCH 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.CONT RIM BOARD W/ A35 CLIP AT 16" O.C. 7.BOUNDARY NAILING, SEE PLAN 8.CONT DBL 2x BOTTOM PLATE, ATTACH PER SHEARWALL SCHEDULE 9.FLOOR SHEATHING, SEE PLAN 10.112" GYPCRETE, SEE ARCH 8 2 3 1 8 3 2 3 1 10 10 66 3 77 9 9 208 PREFAB TRUSS AT WOOD STUD WALL NO SCALE KEYNOTES: 1.WOOD TRUSS W/ CLIP, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING, SEE SHEARWALL SCHEDULE 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.2x BLOCK BETWEEN EACH TRUSS, W/ (4) 16d NAILS 7.BOUNDARY NAILING, SEE PLAN 8.ROOF SHEATHING, SEE PLAN 9.2x BLOCKING BETWEEN EACH TRUSS (2" WIDER THAN PARAPET STUD) 10.WOOD TRUSS W/ INTEGRAL PARAPET WALL FRAMING AT 24" O.C. 11.PROVIDE 2x BLOCKING AT PANEL EDGE PER SHEARWALL SCHEDULE NOTE: A.SLOPE, WATERPROOF AND DRAIN PER ARCH B.TRUSS MANUFACTURER SHALL DESIGN PARAPET FOR A WIND LOAD INDICATED IN TABLE W/ MAXIMUM DEFLECTION OF 2L/240 C.IN ADDITION TO TYPICAL TRUSS CONNECTION FORCES , TOP AND BOTTOM CHORD TO PARAPET STUD CONNECTIONS SHALL BE DESIGNED FOR THE FORCES GENERATED BY THE PARAPET WIND LOADS 1 2 3 5 4 8 7 4 5 9 6 10 "H " 4 55 11 PARAPET WIND LOAD PARAPET HEIGHT ("H") TOTAL WIND LOAD (ASD)MIN STUD SIZE UP TO 4'-6"39.8 PSF 2x6 5 2 13 9 3 3 5 4 KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.EDGE NAILING, SEE SHEARWALL SCHEDULE 4.2x8 BLOCKING BETWEEN EACH STUD 5.WOOD TRUSS, SEE PLAN 6.2x6 BLOCK AT EACH STUD W/ (4) 8d NAILS 7.(4) 16d NAILS 8.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 9.WALL SHEATHING AS OCCURS, SEE PLAN 10.BOUNDARY NAILING, SEE PLAN 11.ROOF SHEATHING, SEE PLAN 12.CONT 2x BOTTOM PLATE W/ 16d NAILS AT 4" O.C. 13.2x6 AT 16" O.C. 14.2x6 KICKER BRACE AT 32" O.C. W/ (5) 16d NAILS EACH END 15.2x BLOCK AT EACH KICKER W/ (4) 8d NAILS 209 PREFAB TRUSS AT WOOD STUD WALL NO SCALE 6 11 3' - 8 " MA X 10 7 12 8 3 33 1 14 15 1 1 9 206 PREFAB AWNING AT WOOD STUD WALL NO SCALE 6 5' - 0 " MI N 5'-0" MAX 1415 12 7 13 9 5 11 8 10 4 210 WOOD TRUSSES AT WOOD GIRDER TRUSSES NO SCALE KEYNOTES: 1.WOOD TRUSS, SEE PLAN 2.GIRDER TRUSS, SEE PLAN 3.BOUNDARY NAILING, SEE PLAN 4.ROOF SHEATHING, SEE PLAN 1 4 211 WOOD JOIST AT WOOD STUD WALL NO SCALE KEYNOTES: 1.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 2.EDGE NAILING, SEE SHEARWALL SCHEDULE 3.WALL SHEATHING AS OCCURS, SEE PLAN 4.CONT 2x LEDGER W/ (3) 16d NAILS AT EACH STUD 5.WOOD JOIST W/ HANGER, SEE PLAN 6.ROOF SHEATHING, SEE PLAN 7.BOUNDARY NAILING, SEE PLAN 8.WOOD STUD WALL, SEE PLAN 9.2x BLOCKING BETWEEN EACH STUD 10.SIMPSON H2A CLIP EVERY OTHER JOIST 4 5 2' - 0 " MA X . 3 8 2 1 7 6 2 212 WOOD JOIST AT WOOD STUD WALL NO SCALE KEYNOTES: 1.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 2.EDGE NAILING, SEE SHEARWALL SCHEDULE 3.WALL SHEATHING AS OCCURS, SEE PLAN 4.CONT 2x LEDGER W/ (2) 16d NAILS AT EACH STUD 5.WOOD JOIST, SEE PLAN 6.ROOF SHEATHING, SEE PLAN 7.BOUNDARY NAILING, SEE PLAN 8.WOOD STUD WALL, SEE PLAN 9.2x BLOCKING BETWEEN EACH STUD 10.SIMPSON H2A CLIP AT EACH BLOCK 11.2x BLOCK AT 32" O.C. W/ (4) 8d NAILS 4 5 2' - 0 " MA X 3 2 1 7 6 9 8 2 NOTES: A.SEE ARCHITECTURAL DETAILS FOR FIRE-PROOFING REQUIREMENTS 1 3 4 8 10 2 11 KEYNOTES: 1.WOOD TRUSS, SEE PLAN 2.2x4 x 6'-0" LONG AT 48" O.C. W/ (2) 16d NAILS AT EACH TRUSS 3.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 4.WOOD STUD WALL, SEE PLAN 5.WALL SHEATHING AS OCCURS, SEE PLAN 6.WOOD STUD WALL W/ DBL KING STUD EACH SIDE OF 6x12 BLOCK 7.WOOD TRUSS W/ 16d NAILS AT 4" O.C., SEE PLAN 8.BOUNDARY NAILING, SEE PLAN 9.CONT DBL 2x BOTTOM PLATE W/ ATTACHMENT, SEE SHEARWALL SCHEDULE 10.FLOOR SHEATHING, SEE PLAN 11.GYP-CRETE, SEE ARCH 12.6x12 BLOCK W/ HGA10 CLIP TOP AND BOTTOM, EACH END 13.STEEL ATTACHMENT W/ (4) 3 4"Ø LAG SCREWS W/ 4" MIN EMBEDMENT INTO BLOCK 14.CANOPY BY OTHERS, SEE ARCH DRAWINGS FOR LOCATIONS 15.(4) 3 4" Ø LAG SCREWS W/ 4" MIN EMBEDMENT INTO BLOCK 16.SOLID BLOCK BETWEEN TRUSSES TO RECEIVE AWNING FASTENERS 17.A35 CLIP AT BOTTOM OF KING STUD 16 33 22 1011 9 10 17 207 WOOD TRUSS AT WOOD STUD WALL NO SCALE NOTES: A.SEE ARCHITECTURAL DETAILS FOR FIRE-PROOFING REQUIREMENTS B.SLOPE, WATERPROOF AND DRAIN PER ARCH 1 2 3 5 4 6 3 KEYNOTES: 1.WOOD TRUSS W/ CLIP, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.2x BLOCKING BETWEEN EACH TRUSS 5.ROOF SHEATHING, SEE PLAN 6.2x BLOCK BETWEEN EACH TRUSS, W/ (4) 16d NAILS 7.BOUNDARY NAILING, SEE PLAN 6 7 4 7 1 2 5 1 PRO F E S S I O N A L EN G I N E E R S T ATE O F I D A H O A 9/ 1 4 / 2 2 14 1 3 4 D VID B . P O R T E R L I C E N SED MECHANICAL ENGINEERING ELECTRICAL ENGINEERING STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com GTCDBPIF22-320