HomeMy WebLinkAboutLETTER - 22-00034 - Nitro Car WashPAVING TYPE:
ASPHALT
CONCRETE
CONCRETE W/ ICE MELT
GEODETIC DATUM = TBD
1
2
A4.1
1
A0.2
C2
6
1
10
5
7
LANE 2
LANE 1
4
10
3
4,593 SF CAR WASH
BUILDING
120' CONVEYOR
15 VACUUM STALLS
MOODY ROAD
N
2
N
D
E
18 VEHICLE
STACKING
PR
I
V
A
T
E
A
C
C
E
S
S
R
O
A
D
10
10
10 10
4' - 0" 6' - 0" 2' - 9" 12' - 6" 12' - 6" 12' - 6" 12' - 6" 12' - 6" 12' - 6" 12' - 6" 12' - 6" 12' - 6" 12' - 6" 2' - 9"2' - 0" 12' - 6" 12' - 6" 12' - 6" 12' - 6" 12' - 6" 2' - 0"6' - 0"
4 PARKING STALLS
3' - 9" 9' - 0" 3' - 6" 9' - 0" 3' - 6" 9' - 0" 3' - 6" 9' - 0" 3' - 6" 9' - 0" 3' - 9" 8' - 0" 14' - 0" 10' - 0" 4' - 6"
15
'
-
0
"
9' - 0"
8' - 0"
6' - 6"
9' - 0"9' - 0"9' - 0"
10' - 0"
2
10' - 0"
7'
-
0
"
7
'
-
0
"
24
'
-
0
"
9
'
-
0
"
3
0
'
-
0
"
2
0
'
-
0
"
7
'
-
0
"
12
'
-
0
"
12
'
-
0
"
20' - 0"
9'
-
0
"
4
'
-
0
"
9
'
-
0
"
12' - 0"
14
'
-
0
"
12' - 0"
29
'
-
9
"
20
'
-
0
"
30
'
-
0
"
14' - 0"
15
'
-
0
"
6' - 0"
3' - 6"
5' - 0"
5'
-
1
"
5' - 1"
47' - 6"125' - 0"55' - 6"
20
'
-
0
"
15
'
-
0
"
7'
-
0
"
7
'
-
0
"
32 17 23.13
32
1
7
2
3
.
1
3
32 17 23.13
8'
-
6
"
7'
-
0
"
8'
-
6
"
14
'
-
0
"
6'
-
0
"
1
4
'
-
0
"
8
9
1:12
5' - 0"
6' - 0"
5' - 0" 9' - 6"
6'
-
0
"
12' - 0"
32 39 13
3' - 6"
TYPICAL
9' - 0" 3' - 6"
32 39 13
32 39 13
8"
D
2
4"
D
4
18
"
18
"
36
"
6"
R
W
2
4"
R
W
3
4' - 6"
ICE MELT
AREA
921 SF
11
22 14 26.19
6"
D
3
?
A7.1
2
33 36 61 12
32' - 2 1/2"
STAMP:
THESE DOCUMENTS HAVE BEEN PRODUCED AS AN
INSTRUMENT OF SERVICE AND ARE INTENDED SOLELY
FOR THE PURPOSE OF CONSTRUCTING, USING AND
MAINTAINING THE PROJECT. SPOTLESS WASH
SOLUTIONS USA INC, AS THE ARCHITECT OF RECORD
FOR THE PROJECT RETAINS OWNERSHIP OF THESE
DOCUMENTS.
ANY USE OF THESE DOCUMENTS OR USE OF THIS
DESIGN, IDEAS OR CONCEPTS DESCRIBED HEREIN IN
WHOLE OR PART BY ANY MEANS WHATSOEVER IS
STRICTLY PROHIBITED EXCEPT BY WRITTEN CONSENT
OF SPOTLESS WASH SOLUTIONS USA INC.
REPRODUCTION OF THIS DOCUMENT IS STRICTLY
PROHIBITED EXCEPT BY WRITTEN CONSENT OF
SPOTLESS WASH SOLUTIONS USA INC.
COPYRIGHT 2022
SPOTLESS WASH SOLUTIONS USA INC.
CHECKED:
DATE:
JOB NUMBER:
ISSUED FOR:
SHEET NUMBER:
SP
O
T
L
E
S
S
W
A
S
H
S
O
L
U
T
I
O
N
S
PO
B
O
X
5
4
5
6
TW
I
N
F
A
L
L
S
,
I
D
A
H
O
8
3
3
0
3
PH
.
(
2
0
8
)
8
4
1
-
4
5
2
4
DRAWN:
BI
N
D
I
N
G
02/15/2022
PERMIT REVIEW SET
NOT FOR CONSTRUCTION
JH
21005
ASI-01
A0.1
SITE PLAN
AS
NI
T
R
O
C
A
R
W
A
S
H
RE
X
B
U
R
G
,
I
D
13
7
1
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
8
6/30/22
SITE PLAN NOTES
A. DRAWINGS & SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF THE CONTRACT
DOCUMENTS, REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE COMPLETE SCOPE OF
WORK. NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION IF INCONSISTENCIES,
CONTRADICTIONS OR OMISSIONS ARE DISCOVERED.
B. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT FOUND,
NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION.
C. UNLESS NOTED OTHERWISE SLOPE GRADE MAXIMUM 2% WITHIN 10' OF BUILDING, THEN
MAXIMUM 5% TO MATCH EXISTING GRADE ELEVATIONS. SLOPE ALL WALKING SURFACES
MAXIMUM 5% IN THE DIRECTION OF TRAVEL AND MAXIMUM 2% AT LANDING, CHANGE OF
DIRECTION, AND PERPENDICULAR TO DIRECTION OF TRAVEL.
D. UNLESS NOTED OTHERWISE FOR ALL EXTERIOR CONCRETE PAVEMENT PROVIDE MINIMUM 6"
TYPE II, COMPACTED 95%.
E. SEE LANDSCAPE PLANS FOR PLANTING AND IRRIGATION INFORMATION.
F. SEE CIVIL DRAWINGS FOR GRADING, DRAINAGE AND UTILITIES.
G. ALL WORKS TAKES PLACE DURING A SINGLE AND ONLY PHASE OF THE PROJECT.
H. NOT ALL UNDERGROUND PIPING AND CONDUITS FROM BUILDING TO RECLAIM TANKS IS
IDENTIFIED ON THIS SHEET. SEE A1.3 AND A7.1 FOR ADDITIONAL REQUIREMENTS.
I. REFER TO SHEET C.3.1 OVERALL SITE PLAN FOR SNOW STORAGE LOCATIONS.
1/16" = 1'-0"
SITE PLAN1
SHEET NOTES
1 PROPERTY LINE
2 BUILDING SETBACK
3 VACUUM PRODUCER PAD
4 TRASH ENCLOSURE
5 STAINLESS STEEL ISLAND FORM, FILL WITH CONCRETE
6 ESCAPE LANE
7 TRANSFORMER PAD, SEE CIVIL/ELECTRICAL
8 RECLAIM OUTLET TO SANITARY SEWER, SEE CIVIL
9 SANITARY SEWER CLEANOUT, SEE RECLAIM A7.1
10 SIGN, POST, "DO NOT ENTER"
11 VAN ACCESSIBLE PARKING STALL & SIGN. REFER TO C.3.1 CIVIL SITE PLAN & 4/C.3.2 TYPICAL
HANDICAP SIGN DETAIL
12 LIFT STATION
KEYNOTES
MARK:DESCRIPTION:
22 14 26.19 PRESLOPED TRENCH DRAIN, ACO S200K WITH SLOTTED IRON 8" LOAD CLASS F GRATE
(OR APPROVED EQUAL)
32 17 23.13 PAINTED PAVEMENT MARKING, WHITE
32 39 13 METAL BOLLARDS
33 36 61 UNDERGROUND REINFORCED CONCRETE WASTEWATER RECLAIM TANKS
0'16'8'32'
NORTH
SITE ANALYSIS
ADDRESS : 1371 N 2ND E
REXBURG, ID
ZONING : COMMERCIAL
SITE AREA : 51,817 SF
BUILDING AREA:4,593 SF
BUILDING HEIGHT:28'
COMMERCIAL ZONE C:
SETBACKS:
-FRONT / SIDE: 10' (ABUTTING PUBLIC THOROUGHFARE)
-BACK: 0'' (NO DEDICATED ALLEY OR PUBLIC WAY)
-SIDES: 0' (ADJACENT COMMERCIAL OR INDUSTRIAL)
PARKING : USE -OTHER
1 SPACE PER 1,000 SF OF FLOOR AREA (4,593sf)
REQUIRED PROVIDED
5 19
MINIMUM 1 ADA VAN ACCESSIBLE SPACE PER SECTION 1106.1 & 1106.5
CITY OF REXBURG, ID DEVELOPMENT CODE
REVISIONS
#DATE
1 5/4/22
2 6/30/22
STAMP:
THESE DOCUMENTS HAVE BEEN PRODUCED AS AN
INSTRUMENT OF SERVICE AND ARE INTENDED SOLELY
FOR THE PURPOSE OF CONSTRUCTING, USING AND
MAINTAINING THE PROJECT. SPOTLESS WASH
SOLUTIONS USA INC, AS THE ARCHITECT OF RECORD
FOR THE PROJECT RETAINS OWNERSHIP OF THESE
DOCUMENTS.
ANY USE OF THESE DOCUMENTS OR USE OF THIS
DESIGN, IDEAS OR CONCEPTS DESCRIBED HEREIN IN
WHOLE OR PART BY ANY MEANS WHATSOEVER IS
STRICTLY PROHIBITED EXCEPT BY WRITTEN CONSENT
OF SPOTLESS WASH SOLUTIONS USA INC.
REPRODUCTION OF THIS DOCUMENT IS STRICTLY
PROHIBITED EXCEPT BY WRITTEN CONSENT OF
SPOTLESS WASH SOLUTIONS USA INC.
COPYRIGHT 2022
SPOTLESS WASH SOLUTIONS USA INC.
CHECKED:
DATE:
JOB NUMBER:
ISSUED FOR:
SHEET NUMBER:
SP
O
T
L
E
S
S
W
A
S
H
S
O
L
U
T
I
O
N
S
PO
B
O
X
5
4
5
6
TW
I
N
F
A
L
L
S
,
I
D
A
H
O
8
3
3
0
3
PH
.
(
2
0
8
)
8
4
1
-
4
5
2
4
DRAWN:
BI
N
D
I
N
G
02/15/2022
PERMIT REVIEW SET
NOT FOR CONSTRUCTION
21005
ASI-01
A1.6a
EQUIPMENT
SCHEDULE
AS
NI
T
R
O
C
A
R
W
A
S
H
RE
X
B
U
R
G
,
I
D
13
7
1
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
8
6/30/22
E100 PUMPS AND MOTORS
ITEM DESCRIPTION UNLOADED FURNISHED
SET IN
PLACE INSTALLED
CONDUIT
OH / UG
POWER
VOLTAGE (V)
CONTROL
VOLTAGE
TUNNEL
CONTROL
FUNCTION
CONTROL WIRE
SPECIFICATION
CONTROL WIRE QUANTITY/
TYPE
CONTROL CONNECTION
TYPE
CONTROL FED FROM/ FEEDS
TO POWER FEED FROM/FEEDS TO HARDWIRE
PROVIDE
CONDUIT(S)
PROVIDE
VALVES PLUMBING IN
PLUMBING IN
PIPE SIZE
PLUMBING
OUT
PLUMBING
OUT PIPE SIZE
STARTUP
TEST
BALANCE MOUNTING COMMENTS
E101 PUMP HFX; HSW PUMP 1;GC O O O UG 480VAC - 0 PREWIRED PREWIRED PREWIRED PREWIRED HA/ UNIT VFD/ MOTOR GC GC O 2" O 2" O FRAME/ SLAB GRUNDFOS CRE10-10 N-GJ-A-E-HQQE
E101a PRESSURE TRANSDUCER - O - GC UG - 24VDC 0 SOUTHWIRE
MCTC-18-3S-1
1/SENSOR CABLE TERMINAL BLOCK MCC/ TRANSDUCER - GC GC - - -- - - -
E102 PUMP HFX; HSW PUMP 2;GC O O O UG 480VAC 0 PREWIRED PREWIRED PREWIRED PREWIRED HA/ UNIT VFD/ MOTOR GC GC O 2" O 2" O FRAME/ SLAB GRUNDFOS CRE10-10 N-GJ-A-E-HQQE
E102a PRESSURE TRANSDUCER - O - GC UG - 24VDC 0 SOUTHWIRE
MCTC-18-3S-1
1/SENSOR CABLE TERMINAL BLOCK MCC/ TRANSDUCER - GC GC - - -- - - - -
E103 BACK-UP PUMP; (FUTURE) NO CONNECTIONS - O O O - - - 0 - - - - - - - - - - - - - - -
E103a PRESSURE TRANSDUCER O - GC UG - 24VDC 0 SOUTHWIRE
MCTC-18-3S-1
1/SENSOR CABLE TERMINAL BLOCK MCC/ TRANSDUCER - GC GC - - -- - - - -
E104 PUMP; SUMP RECLAIM; MAIN SUPPLY GC O GC GC UG 480VAC - 0 PREWIRED PREWIRED PREWIRED PREWIRED CWMS VFD/ MOTOR GC GC - - - GC 6" O TANK MAKE SURE PUMP MOTOR ROTATES IN CORRECT DIRECTION
E104dd PRESSURE TRANSDUCER O - GC UG - 24VDC 1/SENSOR CABLE TERMINAL BLOCK MCC/ TRANSDUCER - GC GC - - -- - - RECLAIM MAIN
E104ee PRESSURE TRANSDUCER O - GC UG - 24VDC 1/SENSOR CABLE TERMINAL BLOCK MCC/ TRANSDUCER - GC GC - - -- - - RECLAIM NIGHT
E104s MOTOR HEAT SENSOR ON PUMP - O - - UG - - 0 - - - - - GC GC - - - - - - TANK
E104y LOW LEVEL FLOAT; SUMP RECLAIM O O GC GC UG - 4-20mA 0 SOUTHWIRE
MCTC-18-3S-1
1/SENSOR CABLE TERMINAL BLOCK MCC TC CWMS/ METER GC GC - -- - - - TANK
E105 PUMP; SUMP RECLAIM; AT NIGHT TRENCH FLUSH GC O GC GC UG 480VAC - 0 PREWIRED PREWIRED PREWIRED PREWIRED CWMS STARTER/ MOTOR GC GC - - - GC 4" O TANK
E106 PUMP; RECLAIM HIGH PRESSURE GC O GC O UG 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED VFD/ MOTOR GC GC 3" GC (2) 1.5" GC 1" SS O SLAB
E107 PUMP; RECLAIM HIGH PRESSURE GC O GC O UG 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED VFD/ MOTOR GC GC 3" GC (2) 1.5" GC 1" SS O SLAB
E108 PUMP; MUD BLAST GC O GC O UG 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC VFD/ MOTOR GC GC 3" GC 3" GC 1.25" SS O SLAB GRUNDFOS CR 45-5-2 A-G-A-E-HQQE
E108a PRESSURE TRANSDUCER GC O - GC UG - 24VDC 0 SOUTHWIRE
MCTC-18-3S-1
1/SENSOR CABLE TERMINAL BLOCK MCC/ TRANSDUCER - GC GC - - -- - - PUMP
E109 PUMP; RO PRODUCTION - O - O UG 480VAC - 0 - - PREWIRED - - GC GC - - - - - - SKID
E109a LOW/HIGH LEVEL FLOAT - O - O OH 480VAC - 0 - - - - - - GC - - - - - - TANK
E110 PUMP; RO DELIVERY - O - O UG 480VAC - 1 - - PREWIRED - - GC GC - - - - - - SKID
E111 PUMP; RO REJECT RECOVERY - O - O UG 480VAC - 0 - - - - - GC GC - - - - - - SLAB
E111a LOW LEVEL FLOAT; RO REJECT RECOVERY - O - O OH - - 0 - - - - - - GC - - - - - - TANK
E112 PUMP; PRESSURE WASHER W/ WALL BRACKET GC O GC O UG 480VAC - 0 - - - - HA/ UNIT STARTER GC GC 1.5" HSW GC 1" TYPE K O 0.5" SS O WALL (BRACKET) AALADIN 443-SS W/ SOAP CONTAINER AND CLUTCH
E121 MOTOR, TOP BRUSH GC O O O OH 480VAC 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC1 VFD/ MOTOR GC GC - - - - - O ARCH PECO ELECTRIC MOTOR IN TUNNEL
E122a MOTOR, WRAPS 1 DS GC O O O UG 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC1 VFD/ MOTOR GC GC - - - - - O ARCH PECO ELECTRIC MOTOR IN TUNNEL
E122b MOTOR, WRAPS 1 PS GC O O O UG 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC1 VFD/ MOTOR GC GC - - - - - O ARCH PECO ELECTRIC MOTOR IN TUNNEL
E123a MOTOR, ROCKER 1 PS GC O O O UG 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC1 VFD/ MOTOR GC GC - - - - - O PEDESTAL PECO ELECTRIC MOTOR IN TUNNEL
E123b MOTOR, ROCKER 1 DS GC O O O UG 480 - 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC1 VFD/ MOTOR GC GC - - - O PEDESTAL PECO ELECTRIC MOTOR IN TUNNEL
E124a MOTOR, ROCKER 2 PS GC O O O UG 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC1 VFD/ MOTOR GC GC - - - - - O PEDESTAL PECO ELECTRIC MOTOR IN TUNNEL
E124b MOTOR, ROCKER 2 DS GC O O O UG 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC1 VFD/ MOTOR GC GC - - - - - O PEDESTAL PECO ELECTRIC MOTOR IN TUNNEL
E125 MOTOR, TOP BRUSH 2 GC O O O OH 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC1 VFD/ MOTOR GC GC - - - - - O ARCH PECO ELECTRIC MOTOR IN TUNNEL
E126a MOTOR, WRAPS 2 DS GC O O O OH 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC1 VFD/ MOTOR GC GC - - - - - O ARCH PECO ELECTRIC MOTOR IN TUNNEL
E126b MOTOR, WRAPS 2 PS GC O O O OH 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC1 VFD/ MOTOR GC GC - - - - - O ARCH PECO ELECTRIC MOTOR IN TUNNEL
E127a MOTOR, TIRE SHINE DS GC O O O UG 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC1 VFD/ MOTOR GC GC - - - - - O EQUIP PECO ELECTRIC MOTOR IN TUNNEL
E127b MOTOR, TIRE SHINE PS GC O O O UG 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC1 VFD/ MOTOR GC GC - - - - - O EQUIP PECO ELECTRIC MOTOR IN TUNNEL
E130 MOTOR; SPEED DOOR & CONTROL BOX; EXIT GC O O O UG 480VAC 1 14/3 SHIELDED 3 CONDUCTOR SHIELDED x2 MCC1 TC/ UNIT CONTROLLER HA/ UNIT VFD/ MOTOR GC GC - - - - - O WALL RYTEC PREDADOOR; VFD ON WALL NEXT TO DOOR
E000 WATER PROCESSING / BOILER SYSTEMS
ITEM DESCRIPTION UNLOADED FURNISHED
SET IN
PLACE INSTALLED
CONDUIT
OH / UG
POWER
VOLTAGE (V)
CONTROL
VOLTAGE HARDWIRE
WIRE DEVICE TO
CONTROLLER
PROVIDE
CONDUIT(S)PLUMBING IN
PLUMBING IN
PIPE SIZE
PLUMBING
OUT
PLUMBING
OUT PIPE SIZE
STARTUP
TEST
BALANCE MOUNTING COMMENTS
E001a BACKFLOW PREVENTER; 3" (PROCESS WATER) - GC GC GC -- - - - - GC 3" GC 3" - - INSTALL RPBP'S IN PARALLEL
E001b BACKFLOW PREVENTER; 1 1/2" (DOMESTIC) - GC GC GC - -- - - - GC 1.5" GC 1.5" - - INSTALL RPBP'S IN PARALLEL
E002 WATER SOFTENER SYSTEM; DU-PLEX GC O GC GC UG (2) 120VAC - GC PREWIRED GC GC 2" GC 2" GC SLAB VWW VS2-2000-210 - SKID MOUNTED
E003a BOILER: UHE; ICE MELT GC O GC GC UG 120VAC - GC PREWIRED GC GC 1.5" GC 1.5" GC SLAB 400,000 BTU
E003b ICE MELT MANIFOLDS; MULTIPLE - SEE PLAN - O - - - - -- - - - - - - - SLAB SEE VENDORS DESIGN
E003c ICE MELT SENSOR - O - - UG - 4-20mA GC GC GC - - - - - PAVING SEE VENDORS DESIGN
E003d THERMOSTAT SENSOR - O GC GC OH - 4-20mA GC GC GC - - - - - PAVING SEE VENDORS DESIGN
E004 BOILER; UHE; WATER GC O GC GC UG 120VAC - GC GC GC GC 2" GC 2" GC SLAB 400,000 BTU
E010 TRENCH TRASH COLLECTION DRAIN; SWIRLY GC O GC GC - - -- - - GC - GC 10" - TRENCH FORM IN AND POUR IN PLACE WITH TUNNEL
CONVEYOR TRENCH CONCRETE
E011 TANK 1; RECLAIM; 3,000 GA GC GC GC GC - - - - - - GC 12" GC 8" - GROUND SEE SHEET A7.1
E012 TANK 2; RECLAIM; 3,000 GA GC GC GC GC - - - - - - GC 8" GC 8" - GROUND SEE SHEET A7.1
E013 TANK 3; RECLAIM; 3,000 GA GC GC GC GC - - - - - - GC 8" GC 8" - GROUND SEE SHEET A7.1
E014 TANK 4; SAND/OIL INTERCEPTOR; 3,000 GA GC GC GC GC -- - - - - GC 8" GC 8" - GROUND SEE SHEET A7.1
E015 TANK 5; LIFT STATION; 1,500 GA GC GC GC GC - - - - - - GC 8" GC 8" - GROUND SEE SHEET A7.1
E020 RECLAIM FILTER, 115VAC; 60HZ GC O GC O UG 120VAC - GC - GC GC 6" GC 6" - SLAB NETAFIM; APOLLO, 5 UNIT TWIN, 4" WASTE
E030 RO UNIT SKID; 14,400 GPD GC O GC O UG - 4-20mA - - - GC 1" GC 1" SLAB -
E030a RO CARBON FILTER (GAC)- O O O UG - - - - - - - - - - SKID -
E030b RO PREFILTER - O O O - - - - - - - - - - - SKID -
E030c RO STORAGE TANK 1; 1,500 GA GC O O O - - - - - - GC GC - SLAB -
E030d RO REJECT TANK 2; 1,500 GA GC O O O - - - - - - GC GC - SLAB -
E200 HYDRAULICS
ITEM DESCRIPTION UNLOADED FURNISHED
SET IN
PLACE INSTALLED
CONDUIT
OH / UG
POWER VOLTAGE
(V)
CONTROL
VOLTAGE
TUNNEL
CONTROL
FUNCTION CONTROL WIRE SIZE/ TYPE
CONTROL WIRE QUANTITY/
TYPE CONTROL CONNECTION TYPE
CONTROL FED FROM/ FEEDS
TO POWER FEED FROM/FEEDS TO HARDWIRE
WIRE DEVICE TO
CONTROLLER
PROVIDE
CONDUIT(S)PLUMBING IN
PLUMBING
OUT
STARTUP
TEST
BALANCE MOUNTING COMMENTS
E201 PUMP, HYDRAULIC, CONVEYOR GC O GC O UG 480VAC - 1 PREWIRED PREWIRED PREWIRED PREWIRED MCC VFD/ MOTOR GC GC GC O O O SLAB
E201a LOW OIL SENSOR - O - O UG - 24VAC 1 SOUTHWIRE MCTC-18-3S-1 1/SENSOR CABLE CEE CONDUIT BODY/FLEXIBLE
CONDUIT/JBOX
TC/ JBOX-CONDULET MCC CONTROLLER/ UNIT GC GC GC - - - NEEDS A SEPARATE CONDUIT TO MCC ; MULTIPLE LOW OIL LINES CAN SHARE
CONDUIT WHEN EQUIPMENT IS ADJACENT TO ONE-ANOTHER.
E300 AIR MOVEMENT
ITEM DESCRIPTION UNLOADED FURNISHED
SET IN
PLACE INSTALLED
CONDUIT OH /
UG
POWER
VOLTAGE (V)
CONTROL
VOLTAGE
TUNNEL
CONTROL
FUNCTION CONTROL WIRE SIZE/ TYPE
CONTROL WIRE QUANTITY/
TYPE CONTROL CONNECTION TYPE
CONTROL FED FROM/ FEEDS
TO POWER FEED FROM/FEEDS TO HARDWIRE
WIRE DEVICE TO
CONTROLLER
PROVIDE
CONDUIT(S) PROVIDE VALVES PLUMBING IN
PLUMBING
OUT
STARTUP
TEST
BALANCE MOUNTING COMMENTS
E301 AIR COMPRESSOR 1 GC O GC O UG 480VAC 0 - - - - HA/ UNIT STARTER GC - GC O O O O SLAB CONNECT BOTH COMPRESSORS FROM 3/4" HOSE INTO SINGLE 1" LINE
E302 AIR COMPRESSOR 2 GC O GC O UG 480VAC 0 - - - - HA/ UNIT STARTER GC - GC O O O O SLAB CONNECT BOTH COMPRESSORS FROM 3/4" HOSE INTO SINGLE 1" LINE
E303a BLOWER 1 GC O O O OH 480VAC 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303b BLOWER 2 GC O O O OH 480VAC 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303c BLOWER 3 GC O O O OH 480VAC 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303d BLOWER 4 GC O O O OH 480VAC 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303e BLOWER 5 GC O O O OH 480VAC - 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303f BLOWER 6 GC O O O OH 480VAC - 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303g BLOWER 7 GC O O O OH 480VAC 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303h BLOWER 8 GC O O O OH 480VAC 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303i BLOWER 9 GC O O O OH 480VAC - 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303j BLOWER 10 GC O O O OH 480VAC - 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303k BLOWER 11 GC O O O OH 480VAC - 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303l BLOWER 12 GC O O O OH 480VAC - 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303m BLOWER 13 GC O O O OH 480VAC - 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303n BLOWER 14 GC O O O OH 480VAC - 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303o BLOWER 15 GC O O O OH 480VAC - 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303p BLOWER 16 GC O O O OH 480VAC - 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E303q BLOWER 17 GC O O O OH 480VAC - 1 MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC PREWIRED MCC/ MOTOR GC - GC O - - - BEAM HEAD SYSTEMS
E304 VAC PRODUCER GC O GC O UG 480VAC - 0 BELDEN 8618 1/BELDEN WEATHERBOX VFD/TRANSDUCER MDP/VFD; VFD/MOTOR GC - GC - O O O PAD WIRE VFD IN VACUUM ROOM;SEE VACUTECH DRAWINGS
E304a PRESSURE TRANSDUCER - O - GC UG - 24VDC 0 SOUTHWIRE MCTC-18-3S-1 1/SENSOR CABLE TERMINAL BLOCK MCC/ TRANSDUCER - GC - GC - - - - - -
E305 VAC PRODUCER GC O GC O UG 480VAC - 0 BELDEN 8618 1/BELDEN WEATHERBOX VFD/TRANSDUCER MDP/VFD; VFD/MOTOR GC - GC - O O O PAD WIRE VFD IN VACUUM ROOM;SEE VACUTECH DRAWINGS
E305A PRESSURE TRANSDUCER - O - GC UG - 24VDC 0 SOUTHWIRE MCTC-18-3S-1 1/SENSOR CABLE TERMINAL BLOCK MCC/ TRANSDUCER - GC - GC - - - - - -
SCHEDULE KEY
B- BOBRICK ACCESSORY CATOLOGUE NUMBERS
GC GENERAL CONTRACTOR
O OWNER
OC OWNERS CONSTRUCTION FORCES
NA NOT APPLICABLE
/ R RECESSED APPLICATION
V VARIES
GREY COLOR INDICATES NOT APPLICABLE
EXXX HAVE CUT SHEET(S) FOR THESE ITEMS
DEFINITIONS
FURNISHED
SET IN PLACE
INSTALLED
HARDWIRE
PROVIDE CONDUIT
PROVIDE VALVES
PLUMBING CONNECTION
SUPPLIED TO SITE AT OWNERS OR GENERAL CONTRACTORS CHOSEN LOCATION
MOVED FROM ANY LOCATION ON PROPERTY AND SET IN APPROPRIATE PLACE. THIS LOCATION
SHALL BE CONFIRMED BY THE OWNER OR OWNER'S REPRESENTATIVE
EQUIPMENT TO BE FASTENED, MOUNTED OR SECURED IN PLACE
CONNECT CONDUCTORS FROM SOURCE TO EQUIPMENT; THIS INCLUDES BOTH POWER AND
CONTROL CONDUCTORS
EXTEND APPROPRIATE CONDUIT FROM SOURCE TO EQUIPMENT AND PROVIDE BOX AS
NECESSARY. SEE SCHEDULE FOR ROUTING OVERHEAD OR UNDERGROUND RECESSED
APPLICATION
THIS INCLUDES VALVES AND ALL NECESSARY PLUMBING FITTINGS FOR COMPLETE, CODE
COMPLIANT INSTALLATION. ALL CODE REQUIRED VALVES MAY NOT BE SHOWN. IT IS THE
GENERAL CONTRACTORS
PROVIDE PIPING AND FITTINGS REQUIRED AND MAKE FINAL CONNECTION TO EQUIPMENT FOR
ALL WATER, SEWER, GAS, AND COMPRESSED AIR SYSTEMS
REVISIONS
#DATE
1 6/30/22
T/O FLOOR
100' -0"
3
A7.1
D2
4b4a
SAND / OIL INTERCEPTOR
3
THIRD SETTLING TANK
2
SECOND SETTLING TANK
1
FIRST SETTLING TANK
68
7
DIRECTION OF FLOW
4
11
1110
1110
5
5
5
3
7
7
10
3
33
12 12 12 12
RW
2
RW
3
SL
3
SL
3
SL
3
RW5 RW5 RW5
93.26 (4872.76) IE
LIFT STATION
92.60 IE 92.60 IE 92.27 IE
92.27 IE
C5
a
C5
b
C5
c
C5
d
D3
93.26 IE 91.93 (4871.43) IE
91.75 (4871.25) IE
E105 E104
4"
4"
4"
92.93 IE
2'
-
0
"
92.43 IE92.43 IE
92.93 IE
91.58 (4871.08) IE
91.58 (4871.08) IE
91.42 (4870.92) IE
E011 E012 E013 E014 E015
1
A7.1
3
A7.1
SL
3
SL
3
D2
12
3
4b4a
4
SAND/OIL INTERCEPTOR
2
3
5
1110
3
THIRD SETTLING TANK
7
12
3
5
1110
2
SECOND SETTLING TANK
12
5
1
FIRST SETTLING TANK
68
7
7 1110
DIRECTION OF FLOW
3
1
SL
3
13' - 0"3' - 4"13' - 0"3' - 4"13' - 0"3' - 4"13' - 0"
D3
LIFT STATION
RW
3
RW
2
E105 E104
E014 E015
1 1
12
12
12
RW5 RW5RW5
E013E012E011
T/O FLOOR
100' -0"
T/O FOOTING
97' -10"
B C D
95.56 B.T.
94.00 BP
TRASH PIT CONVEYOR
TRENCH
106
EQUIPMENT
109
WASH
TUNNEL
05 53 00
05 53 00
1FIRST SETTLING
TANK
A7.1
4
A1.2
3
95.52 IE
1/4" / 12"
95.35 IE
8" D2
8" D2
10" D1
93.96 IE
1
A7.1
93.26 IE
1/4" / 12"
T/O FLOOR
100' -0"
93.96 IE
95.35 IE
05 53 00
05 53 00
95.01 TG
03 15 13
10" INLET FROM
TRENCH
8" OUTLET TO
RECLAIM TANK
94.00 BP
A1.2
4
A1.2
4
A1.2
6
A1.2
6
05 53 00.1 05 53 00.1
STAMP:
THESE DOCUMENTS HAVE BEEN PRODUCED AS AN
INSTRUMENT OF SERVICE AND ARE INTENDED SOLELY
FOR THE PURPOSE OF CONSTRUCTING, USING AND
MAINTAINING THE PROJECT. SPOTLESS WASH
SOLUTIONS USA INC, AS THE ARCHITECT OF RECORD
FOR THE PROJECT RETAINS OWNERSHIP OF THESE
DOCUMENTS.
ANY USE OF THESE DOCUMENTS OR USE OF THIS
DESIGN, IDEAS OR CONCEPTS DESCRIBED HEREIN IN
WHOLE OR PART BY ANY MEANS WHATSOEVER IS
STRICTLY PROHIBITED EXCEPT BY WRITTEN CONSENT
OF SPOTLESS WASH SOLUTIONS USA INC.
REPRODUCTION OF THIS DOCUMENT IS STRICTLY
PROHIBITED EXCEPT BY WRITTEN CONSENT OF
SPOTLESS WASH SOLUTIONS USA INC.
COPYRIGHT 2022
SPOTLESS WASH SOLUTIONS USA INC.
CHECKED:
DATE:
JOB NUMBER:
ISSUED FOR:
SHEET NUMBER:
SP
O
T
L
E
S
S
W
A
S
H
S
O
L
U
T
I
O
N
S
PO
B
O
X
5
4
5
6
TW
I
N
F
A
L
L
S
,
I
D
A
H
O
8
3
3
0
3
PH
.
(
2
0
8
)
8
4
1
-
4
5
2
4
DRAWN:
BI
N
D
I
N
G
02/15/2022
PERMIT REVIEW SET
NOT FOR CONSTRUCTION
JH
21005
ASI-01
A7.1
RECLAIM SYSTEM
DETAILS
AS
NI
T
R
O
C
A
R
W
A
S
H
RE
X
B
U
R
G
,
I
D
13
7
1
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
8
6/30/22
SHEET NOTES
1 24" CONTINUOUS PRECAST MANHOLE, LID AND FRAME, TYPICAL.
2 30" CONTINUOUS PRECAST MANHOLE, LID AND FRAME, TYPICAL.
3 FIXED LADDER PROVIDED BY TANK MANUFACTURER, TYPICAL. FIRST LADDER RUNG SHALL BEGIN NO MORE
THAN 12" ABOVE BOTTOM OF TANK AND EXTEND UP INTO TANK GOOSENECK WITH THE HIGHEST
LADDER RUNG NO MORE THAN 12" BELOW MANHOLE RIM ELEVATION.
4 PROVIDE PIPING AT INTERIOR AND EXTERIOR OF GREASE INTERCEPTOR TO MEET LOCALLY ADOPTED
CODES AND STANDARDS. SUBMIT RFI IF DESIGN DOES NOT CONFORM TO LOCAL JURISDICTIONAL
REQUIREMENTS. CONTRACTOR SHALL REVIEW REQUIREMENTS WITH PLUMBING INSPECTOR PRIOR TO
FABRICATION.
5 ALL PIPES TO TANKS AND BETWEEN TANKS ARE 8" SCH40 PVC UNLESS INDICATED OTHERWISE.
6 8" SCH40 PVC WITH CAST IRON GCO - GRADE CLEAN-OUT. COVER TO BE INSCRIBED "SANITARY SEWER
CLEANOUT".
7 EXTEND PIPE DOWN WALL TO HEIGHT INDICATED AND ATTACH WITH P1000-ST 316 STAINLESS STEEL
UNISTRUT PARALLEL TO PIPE WITH SS CUSH-A-CLAMP CONNECTOS. ANCHOR UNISTRUT TO TANK WITH SS
WEDGE ANCHORS AT 12" O.C.
8 3" SCH-40 PVC VENT TO EXTEND TO INSIDE STUD WALL CAVITY AND VTR WITH TERMINATION. ROUTING PER
GC.
10 1 1/2" SCH80 PVC AT LID FOR AIR, SECURE TO WALL TO 3' ABOVE BOTTOM OF TANK WITH SS UNISTRUT, SEE
SHEET A1.2 FOR TERMINATION AT BUILDING.
11 1" SCH80 PVC AT LID FOR OZONE,
SECURE TO WALL TO 3' ABOVE BOTTOM OF TANK WITH SS UNISTRUT.
12 SEE CIVIL FOR CONTINUATION.
GENERAL NOTES
A. TANKS: STRUCTURAL ENGINEERING DESIGN OF TANKS IS RESPONSIBILITY OF THE
CONTRACTOR. PROVIDE STAMPED AND SEALED SHOP DRAWING SUBMITTAL FOR
ARCHITECT'S REVIEW. DESIGN SHALL ASSUME VEHICLE LIVE LOAD FOR (HL-93 DESIGN
TRUCK) = 32 KIP (SINGLE AXLE).
B. THE CIVIL ENGINEER WILL PROVIDE MANHOLE RIM ELEVATIONS. IT IS CONTRACTOR'S
RESPONSIBILITY TO REQUEST / VERIFY RIM ELEVATIONS WITH CIVIL ENGINEER.
C. TANKS: IF TANKS ARE MANUFACTURED WITH MULTIPLE SECTIONS, PROVIDE (2)
CONTINUOUS VOLCLAY WATER STOP STRIPS OR WATERPROOFING MEASURE
RECOMMENDED BY TANK MANUFACTURER AT EACH JOINT.
D. TANKS: MODIFY MANUFACTURER'S STANDARD PRECAST TANK SPECIFICATIONS TO MATCH
REQUIREMENTS INDICATED.
E. TANKS: ALL HOLES FOR INLET / OUTLET PIPES SHALL BE CORE DRILLED. PROVIDE A WATER
TIGHT SEAL (KOR-N-SEAL I OR LINK-SEAL CONNECTORS). GROUTED CONNECTIONS ARE
NOT PERMITTED.
F. TANKS: TANK WATERTIGHTNESS IS RESPONSIBILITY OF THE CONTRACTOR. FILL TANKS
AND TEST WATERTIGHTNESS PRIOR TO BACKFILLING.
G. MANHOLE COVERS AND FRAMES: PROVIDE RECESSED FLUSH HEAVY DUTY TRAFFIC RATED
ASTM A48 FIBERGLASS BOLT DOWN MANHOLE COVER. PROVIDE 32mm (1-1/4") MINIMUM
LETTERS INDICATING "RECLAIM". LABELING AT MANHOLE COVERS WITH LADDERS TO READ
"LADDER".
H. MANHOLE: PRECAST MANHOLE TO EXTEND FROM TOP OF TANK TO UNDERSIDE OF
MANHOLE LID. SET LID PER MANUFACTURER'S INSTRUCTIONS.
I. TANKS: IT IS CONTRACTOR'S RESPONSIBILITY TO REQUEST / VERIFY RIM ELEVATIONS WITH
GRADING PLAN DESIGNER WHEN NOT ILLUSTRATED ON GRADING PLAN.
J. TANKS: SEE EQUIPMENT SCHEDULE FOR TANK RESPONSIBILITY MATRIX.
K. PIPING: ALL PIPING TO TANKS, BETWEEN TANKS, INSIDE OF TANKS AND BACK TO BUILDING
IS RESPONSIBILITY OF THE CONTRACTOR. TERMINATE PIPING A MINIMUM OF 203mm (8")
PAST INSIDE OF TANK. A SINGLE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PIPING
INCLUDING WHERE THE PIPES STUB UP INSIDE THE BUILDING AT THE EQUIPMENT ROOM.
L. PIPING: ALL PIPES TO, BETWEEN AND INSIDE OF TANKS ARE 300mm (12") SCH40 PVC UNLESS
INDICATED OTHERWISE. TERMINATE PVC PIPING A MINIMUM OF 200mm (8") PAST INSIDE
FACE OF TANK WALL.
M. PROTECT EXISTING AND NEW TANKS AND PIPING DURING CONSTRUCTION ACTIVITIES. IT IS
RESPONSIBILITY OF CONTRACTOR FOR CONSTRUCTION DAMAGE TO EXISTING AND NEW
TANK ASSEMBLIES AND PIPING.
N. LADDERS: EXTEND FROM BOTTOM OF TANK TO TOP OF MANHOLE LID. MAXIMUM RISER
FROM TANK BOTTOM TO GRADE AT LID TO BE 305mm (12"). USE BASIS-OF-DESIGN LADDER
OR MANUFACTURED STEP PER LANE POLYPROPYLENE P-10938 OR EQUAL.
O. INSTALL XYPEX WATERPROOFING AT CONCRETE TANK WALLS, TRASH PIT WALLS, PUMP PIT
WALLS, CONVEYOR TRENCH WALLS.
P. ABBREVIATIONS:
a. BP = BOTTOM OF PIT
b. BT = BOTTOM OF TRENCH
c. IE = INVERT ELEVATION AT PIPE
d. TG = TOP OF GRATING
RECLAIM PIPE SCHEDULE
#DESCRIPTION
RW1 6" SCH80 PVC RECLAIM WATER HEADER PIPING FROM FILTER TO PUMPS AND TRENCH FLUSH
RW2 6" SCH80 PVC RECLAIM WATER FROM SUMP PUMP TO FILTER
RW3 4" SCH80 PVC RECLAIM WATER FROM NIGHT TIME SUMP PUMP. STUB UP AT EQUIPMENT ROOM AND
CONNECT TO VERTICAL LEG OF RW4 PUMBING WITH WYE FITTING ARRANGED FOR DOWNWARD FLOW AT
12" ABOVE SLAB
RW4 6" SCH40 PVC RECLAIM WATER TRENCH FLUSH PIPE ASSEMBLY. PROVIDE CONSTANT DOWNWARD
SLOPE EACH DIRECTION FROM WYE FITTING AS ILLUSTRATED TO SIDEWALL OF TRENCH. PIPE INVERT AT
TRENCH TO BE 3" ABOVE GUTTER FLOOR OF TRENCH TO ACCOMMODATE WATERSTOP ASSEMBLIES.
RW5 8" SCH40 PVC RECLAIM WATER SANITARY TEE BETWEEN TANKS. PIPE INVERT AT EACH TANK TO BE SAME
ELEVATION AS INLET PIPE RW1
RECLAIM CONDUIT SCHEDULE
#DESCRIPTION
C5a CONDUIT TO MCC FOR SUMP PUMP VFD CABLES. SEE SHEET A1.2b FOR CONDUIT RUNS AND STUB-UP
LOCATIONS
C5b CONDUIT TO MCC FOR SUMP PUMP VFD CABLES. SEE SHEET A1.2b FOR CONDUIT RUNS AND STUB-UP
LOCATIONS
C5c 1" PVC CONDUIT TO TC FOR FLOAT CONDUCTORS
C5d 1" PVC CONDUIT TO TC FOR HEAT SENSOR CONDUCTORS
1/4" = 1'-0"
RECLAIM SYSTEM SECTION1
1/4" = 1'-0"
RECLAIM SYSTEM PLAN VIEW2
NORTH
0'4'2'8'
1/4" = 1'-0"
RECLAIM / TRASH PIT / TRENCH SECTION3 3/4" = 1'-0"
TRASH PIT4
KEYNOTES
MARK:DESCRIPTION:
03 15 13 WATERSTOP, SERRATED
05 53 00 METAL GRATING, OWNER PROVIDED, AMD 1.5x1.5x1.5 MOLDED PROFILE NUMBER 14, YELLOW, OR
APPROVED EQUAL
05 53 00.1 1.75" x 1.75" x 1/4" FEMALE EMBED ANGLE AT PERIMETER OF SLAB OPENING FOR OWNER
PROVIDED GRATING. PROVIDE 1/4" x 2" NELSON STUDS AT 12" O.C.
REVISIONS
#DATE
1 6/30/22
fl
fl
fl
fl
fl
fl
fl
fl
fl
toe toe toe toe toe toe toe toe
toetoetoetoetoetoetoetoetoe
toe
toetoetoe
eee
eee
pp
sd
sd
pp
to
b
t
o
b
to
b
t
o
b
to
b
tobtobtobtobtobtobtobtobtobtob
tob tob tob tob tob tob tob tob tob
tob
to
b
to
b
to
b
to
b
to
b
to
b
to
b
to
b
t
o
b
to
b
to
b
to
b
to
b
to
b
to
b
to
b
tob
to
b
14'' w 14'' w 14'' w 14'' w 14'' w
s
s
s
IR
R
IR
R
IR
R
IR
R
IR
R
IR
R
16'' W16'' W16'' W16'' W16'' W16'' W16'' W16'' W16'' W16'' W16'' W16'' W16'' W16'' W
SS
SD SD
SD
8'
'
W
8'
'
W
8'
'
W
8'
'
W
8'
'
W
8'
'
W
8'
'
W
8'
'
W
S s
S
s
sssssssssss
S
SSSSSSSS S
SS
SS
SS
EX-SSMH - 1
100LF 4" WATER SERVICE
49LF 4" WATER SERVICE
8LF 4"
WATER SERVICE
4878
48
7
8
4
8
7
8
4878
4
8
7
8
4878
4878
48784878
4879
4879
STRUCTURE - (22)
RIM: 4868.10
INV: 4872.02 4" (N)
SS LIFT STATION
RIM: 4879.00
INV IN: 4870.59 8" (S)
INV IN: 4871.08 8" (W)
INV OUT: 4871.08 8" (N)
INV OUT: 4871.25 4" (E)
REC TANK 2
RIM: 4878.24
INV IN: 4872.43 8" (W)
INV OUT: 4872.10 8" (E)
REC TANK 1
RIM: 4878.19
INV IN: 4872.76 8" (N)
INV OUT: 4872.43 8" (E)
SSMH 5
RIM: 4878.03
INV IN: 4858.00 12" (E)
INV IN: 4858.23 8" (S)
INV OUT: 4857.90 12" (W)
SS PLUG - 2
INV OUT: 4873.50 8" (S)
SS PLUG - 1
INV OUT: 4873.50 4" (S)
INV: 4872.93 4" (E)
SSMH 3
RIM: 4872.37
INV IN: 4872.00 4" (W)
SSMH 4
RIM: 4878.63
INV OUT: 4870.86 8" (N)
40LF OF 4" SS @ 1.41%
91LF OF 4" SS @ 1.00%
68LF OF 8" SS @ 0.40%
15
0
L
F
O
F
8
"
S
S
@
8
.
5
8
%
121LF OF PRESSURIZED SS
36LF OF 8" SS @ 0.97%
GI 1
RIM: 4878.47
INV IN: 4871.93 4" (N)
INV IN: 4871.77 8" (W)
INV IN: 4871.93 4" (S)
INV OUT: 4871.43 8" (E)
9LF OF 4" SS @ 1.00%
REC TANK 3
RIM: 4878.32
INV IN: 4872.10 8" (W)
INV OUT: 4871.77 8" (E)
28LF OF 8" SS @ 2.62%
4
8
7
8
48
7
8
48
7
8
8" SS PIPE TO SURFACE - SEE ARCHITECTURAL PLANS FOR DETAILS
3" SS PIPE TO SURFACE - SEE ARCHITECTURAL PLANS FOR DETAILS
1 5
RE
V
I
S
I
O
N
S
RE
V
#
DA
T
E
DR
A
W
I
N
G
I
N
F
O
DA
T
E
DE
S
I
G
N
E
D
DR
A
W
N
*S
E
E
G
E
N
E
R
A
L
N
O
T
E
S
S
H
E
E
T
WA
R
N
I
N
G
0
1
2
IF
T
H
I
S
B
A
R
D
O
E
S
N
O
T
ME
A
S
U
R
E
2
"
T
H
E
N
DR
A
W
I
N
G
I
S
N
O
T
T
O
S
C
A
L
E
CI
T
Y
R
E
V
I
E
W
S
E
T
ww
w
.
h
o
r
r
o
c
k
s
.
c
o
m
PAGE
C
PR
O
J
E
C
T
CH
E
C
K
E
D
D
B
A
#
2 3 4
21
9
4
S
n
a
k
e
R
i
v
e
r
P
k
w
y
.
,
S
u
i
t
e
2
0
5
Id
a
h
o
F
a
l
l
s
,
I
D
8
3
4
0
2
(2
0
8
)
5
2
2
-
1
2
2
3
PRELIMINARY
NOT FOR
CONSTRUCTION
H
O R R O
C
K
S
E
N
G I N E E R
S
0 30'60'
SCALE: 1" = 30'
N
ID
-
L
D
-
4
0
7
0
-
2
1
CJ
F
TL
M
JB
F
05
/
0
3
/
2
0
2
2
OV
E
R
A
L
L
U
T
I
L
I
T
Y
P
L
A
N
RE
X
B
U
R
G
N
O
R
T
H
N
I
T
R
O
C
A
R
W
A
S
H
10
0
E
M
O
D
D
Y
R
D
,
RE
X
B
U
R
G
,
I
D
A
H
O
10
C.5.0
SHEET C.7.0
SH
E
E
T
C
.
7
.
2
SH
E
E
T
C
.
7
.
1
MOODY ST
NO
R
T
H
2
N
D
E
A
S
T
WATER KEYNOTES
TIE INTO EXISTING 8" WATER MAIN
INSTALL 8" DUCTILE IRON PIPE (PER CITY OF CITY OF REXBURG
STANDARD), LENGTH PER PLANS, MUST MAINTAIN 5' COVER
INSTALL FIRE HYDRANT PER ISPWC SD-404. FIRE HYDRANT TO MEET
CITY OF REXBURG STANDARDS.
INSTALL 6" X 8" TEE WITH GATE VALVE PER CITY OF REXBURG
STANDARDS.
INSTALL 4" WATER SERVICE STUB PER ISPWC SD-402. STUBS PER
CITY OF REXBURG STANDARD. INCLUDE PLUG, SEE ARCHITECTS
PLANS FOR CONTINUATION
INSTALL 8" PLUG
POTABLE & NON-POTABLE VERTICAL LINE CROSSING PER ISPWC
SD-407, MINIMUM 1.5' VERTICAL SEPARATION
INSTALL 8" X 8" TEE
INSTALL 8" GATE VALVE
INSTALL 16" X 4" TEE
36
37
38
39
40
41
42
43
44
45
SEWER KEYNOTES
INSTALL RECLAIM TANKS AND RECLAIM SYSTEM PER
ARCHITECTURAL PLANS
INSTALL 4" SANITARY SEWER SERVICE LINE (LENGTH PER PLANS),
INCLUDE PLUG, SEE ARCHITECTS PLANS FOR CONTINUATION
INSTALL 6" SANITARY SEWER SERVICE LINE (LENGTH PER PLANS),
INCLUDE PLUG, SEE ARCHITECTS PLANS FOR CONTINUATION
INSTALL 8" SANITARY SEWER SERVICE LINE (LENGTH PER PLANS),
INCLUDE PLUG, SEE ARCHITECTS PLANS FOR CONTINUATION
INSTALL SEWER CLEANOUT WITH TRAFFIC RATED LID PER ISPWC
SD-506
INSTALL SANITARY SEWER MAIN LINE (SIZE, LENGTH, AND SLOPE
PER PLANS)
INSTALL 1500 GALLON GREASE INTERCEPTOR PER ARCHITECTURAL
PLANS
INSTALL SANITARY SEWER MANHOLE PER ISPWC SD-501A, SIZE PER
PLAN
INSTALL GREASE INTERCEPTOR SAMPLING PORT
1500 GALLON CONCRETE VAULT FOR LIFT STATION
51
52
53
54
55
56
57
58
59
60
40
51
51
52
52
54
56
56
56
56
59
52 60
58
58
TIE INTO EXISTING SS MANHOLE
CONTRACTOR TO FIELD VERIFY LOCATION
45
42
42
53
40 LF
52 LF
35 LF
57
40 LF
INSTALL SS RECLAIM TANK SERVICES
PER ARCHITECTURAL PLANS
PROPOSED BUILDING
FFE = 4879.50'
ARCH PLAN 100
TIE IN TO EXISTING
SS, CONTRACTOR TO
FIELD VERIFY DEPTH
AND LOCATION
1.LIFT STATION TO BE DESIGNED BY OTHERS
2.RECLAIM SYSTEM TO BE DESIGNED BY ARCHITECT.
SHEET NOTE
55