HomeMy WebLinkAboutPLANS - 21-00892 - 3448 N 125 E - New Commercial Shop (2)GENERAL NOTES: BUILDING INFORMATION 1, MATERIAI S ASTM DESCRIPTION STRUCTURAL STEEL PLATE A529 A572 A1011 HOT ROLLED MILL SHAPES A36 A529 A500 HHS ROUND A500 HHS RECTANGULAR A500 COLD FORM SHAPES A653 / A1011 ROOF AND WALL SHEETING A653 / A792 BOLTS A307 / A325 / A490 CABLE A475 RODS A529 / A572 4 SHOP COAT PRIMER IS INTENDED TO PROTECT THE STEEL FRAMING FOR A SHORT PERIOD OF TIME. STORAGE IN EXTREME COLD TEMPERATURES OR WINTER SNOW CONDITIONS, INCLUDING TRANSPORTATION ON SALTED OR CHEMICALLY TREATED ROADS WILL ADVERSELY AFFECT THE DURABILITY AND LONGEVITY OF THE PRIMER. THE COAT OF SHOP PRIMER DOES NOT PROVIDE THE UNIFORMITY OF APPEARANCE, OR THE DURABILITY AND CORROSION RESISTANCE OF A FIELD APPLIED FINISH COAT OF PAINT OVER A SHOP PRIMER. MINOR ABRASIONS TO THE SHOP COAT PRIMER CAUSED BY HANDLING, LOADING, SHIPPING, UNLOADING AND ERECTION ARE UNAVOIDABLE AND ARE NOT THE RESPONSIBILITY OF THE METAL BUILDING MANUFACTURER. METAL BUILDING MANUFACTURER IS NOT RESPONSIBLE FOR THE DETERIORATION OF THE PRIMER OR CORROSION THAT MAY RESULT FROM ATMOSPHERIC AND ENVIRONMENTAL CONDITIONS NOR THE COMPATIBILITY OF THE PRIMER TO ANY FIELD APPLIED COATING. 3. BUILDING ERECTION NOTES: THE GENERAL CONTRACTOR AND/OR ERECTOR IS RESPONSIBLE TO SAFELY AND PROPERLY ERECT THE METAL BUILDING SYSTEM IN CONFORMANCE WITH THESE DRAWINGS, OSHA REQUIREMENTS, AND EITHER MBMA OR CSA S16 STANDARDS PERTAINING TO PROPER ERECTION. TEMPORARY SUPPORTS SUCH AS GUYS, BRACES, FALSEWORK, CRIBBING OR OTHER ELEMENTS FOR ERECTION ARE TO BE DETERMINED, FURNISHED AND INSTALLED BY THE ERECTOR. THESE SUPPORTS MUST SECURE THE STEEL FRAMING, OR PARTLY ASSEMBLED STEEL FRAMING, AGAINST LOADS COMPARABLE IN INTENSITY TO THOSE FOR WHICH THE STRUCTURE WAS DESIGNED IN ADDITION TO LOADS RESULTING FROM THE ERECTION OPERATION. SECONDARY WALL AND ROOF FRAMING PURLINS, GIRTS AND/OR JOIST) ARE NOT DESIGNED TO FUNCTION AS A WORKING PLATFORM OR TO PROVIDE AS AN ANCHORAGE POINT FOR A FALL ARREST /SAFETY TIE OFF. 4. SPECIAL INSPECTION: SPECIAL INSPECTIONS AND TESTING THAT MAY BE REQUIRED BY GOVERNMENTAL OR OTHER AUTHORITY DURING CONSTRUCTION AND/OR STEEL FABRICATION (COLLECTIVELY, INSPECTIONS ARE NOT THE RESPONSIBILITY OF THE PEMB MANUFACTURER, AND TO THE EXTENT REQUIRED IT SHALL BE THE RESPONSIBILITY OF THE OWNER AND/OR THE OWNER'S REPRESENTITIVE. IN THE EVENT INSPECTIONS ARE REQUIRED, THE OWNER AND/OR THE OWNER'S REPRESENTITIVE SHALL EMPLOY A THIRD PARTY QUALITY ASSURANCE TESTING AGENCY APPROVED BY THE RELEVANT AUTHORITY. IF SUCH REQUIREMENTS ARE NOT SPECIFICALLY INCLUDED IN THE PEMB MANUFACTURER'S SALES DOCUMENTS, NO INSPECTIONS BY THE PEMB MANUFACTURER OR AT THE PEMB MANUFACTURER'S FACILITY SHALL BE MADE. THE PEMB MANUFACTURER'S FACILITIES ARE ACCREDITED BY IAS AC472. 5. A325 & A490 BOLT TIGHTENING REQUIREMENTS: IT IS THE RESPONSIBILITY OF THE ERECTOR TO ENSURE PROPER BOLT TIGHTNESS IN ACCORDANCE WITH APPLICABLE REGULATIONS. FOR PROJECTS IN THE UNITED STATES, SEE THE RCSC SPECIFICATION FOR STRUCTURAL JOINTS USING A325 OR A490 BOLTS OR FOR PROJECTS IN CANADA, SEE THE CAN/CSA S16 LIMIT STATES DESIGN OF STEEL STRUCTURES FOR MORE INFORMATION. THE FOLLOWING CRITERIA MAY BE USED TO DETERMINE THE BOLT TIGHTNESS (I.E., SNUG -TIGHT" OR "FULLY-PRETENSIONED"), UNLESS REQUIRED OTHERWISE BY LOCAL JURISDICTION OR CONTRACT REQUIREMENTS: A ALL A490 BOLTS SHALL BE "FULLY-PRETENSIONED". B ALL A325 BOLTS IN PRIMARY FRAMING (RIGID FRAMES AND BRACING) MAY BE "SNUG -TIGHT", EXCEPT AS FOLLOWS: "FULLY -PRETENSION" A325 BOLTS IF: a) BUILDING SUPPORTS A CRANE SYSTEM WITH A CAPACITY GREATER THAN 5 TONS. b) BUILDING SUPPORTS MACHINERY THAT CREATES VIBRATION, IMPACT, OR STRESS -REVERSALS ON THE CONNECTIONS. THE ENGINEER -OF -RECORD FOR THE PROJECT SHOULD BE CONSULTED TO EVALUATE FOR THIS CONDITION. c) THE PROJECT SITE IS LOCATED IN A HIGH SEISMIC AREA. FOR IBC -BASED CODES, "HIGH SEISMIC AREA" IS DEFINED AS "SEISMIC DESIGN CATEGORY" OF 'D', E', OR 'F'. SEE THE "BUILDING LOADS" SECTION ON THIS PAGE FOR THE DEFINED SEISMIC DESIGN CATEGORY FOR THIS PROJECT. d) ANY CONNECTION DESIGNATED IN THESE DRAWINGS AS "A325-SC". "SLIP -CRITICAL (SC)" CONNECTIONS MUST BE FREE OF PAINT, OIL, OR OTHER MATERIALS THAT REDUCE FRICTION AT CONTACT SURFACES. GALVANIZED OR LIGHTLY -RUSTED SURFACES ARE ACCEPTABLE. C IN CANADA, ALL A325 AND A490 BOLTS SHALL BE "FULLY-PRETENSIONED", EXCEPT FOR SECONDARY MEMBERS (PURLINS, GIRTS, OPENING FRAMING, ETC.) AND FLANGE BRACES. SECONDARY MEMBERS (PURLINS, GIRTS, OPENING FRAMING, ETC.) AND FLANGE BRACE CONNECTIONS MAY ALWAYS BE SNUG -TIGHT', UNLESS INDICATED OTHERWISE IN THESE DRAWINGS. 6.GENERAL DESIGN NOTES: 1) ALL STRUCTURAL STEEL SECTIONS AND WELDED PLATE MEMBERS ARE DESIGNED IN ACCORDANCE WITH ANSI/AISC 360 "SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS" OR THE CAN CSA S16 "LIMIT STATES DESIGN OF STEEL STRUCTURES", AS REQUIRED BY THE SPECIFIED BUILDING CODE. 2) ALL WELDING OF STRUCTURAL STEEL IS BASED ON EITHER AWS D1.1 "STRUCTURAL WELDING CODE - STEEL" OR CAN/CSA W59 "WELDED STEEL CONSTRUCTION (METAL BUILDING 3) ALL COLD WELDINGFORMEDREQUIRED MEMBERS ARE THE ESIGNEDI ED IN ACCORDANCEOE. WITH ANSI/AISI S100 OR CAN CSA S136 SPECIFICATIONS FOR THE DESIGN OF COLD FORMED STE L STRUCTURAL MEMBERS", AS REQUIRED BY THE SPECIFIED BUILDING CODE. 4) ALL WELDING OF COLD FORMED STEEL IS BASED ON AWS D1.3 "STRUCTURAL WELDING CODE - SHEET STEEL" OR CAN CSA W59 "WELDED STEEL CONSTRUCTION (METAL ARC WELDING)", AS REQUIRED BY THE SPECIFIED BUILDING CODE. 5) ALL NUCOR BUILDING GROUP FACILITIES ARE [AS AC-472 ACCREDITED FOR DESIGN AND FABRICATION OF METAL BUILDING SYSTEMS. FOR PROJECTS IN CANADA, DESIGN AND FABRICATION ARE DONE ONLY IN FACILITIES THAT ARE ALSO CAN/CSA A660 AND W47.1 CERTIFIED. 6) IF JOISTS ARE INCLUDED WITH THIS PROJECT, THEY ARE SUPPLIED AS A PART OF THE SYSTEMS ENGINEERED METAL BUILDING AND ARE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1926.758 OF THE OSHA SAFETY STANDARDS FOR STEEL ERECTION, DATED JANUARY 18, 2001. 7) COLUMN BASE PLATES ARE DESIGNED NOT TO EXCEED THE ALLOWABLE BEARING STRESS OF CONCRETE THAT HAS A MINIMUM COMPRESSIVE STRENGTH OF 3000 P.S.I. AT 28 DAYS. PRIMER COLORS PRIMARY PRIMER COLOR: GRAY SECONDARY PRIMER COLOR: GRAY ROOF SHEETING TYPE: CR GAUGE: 26 FINISH: Galvalume Plus CLIP TYPE: N/A THERMAL BLOCKS: No EPS FOAM SPACER: No ROOF LINE TRIM, PAINTED: Aztec Blue SP YES❑ NOX DOWNSPOUTS PAINTED: GUTTERS PAINTED: YESX NOD INSULATION 3.751NCH (NOT BY MBS) YES❑ NOX PIPE JACKS, SIZE: QUANTITY: YES❑ NOX RIDGE VENTS, 10'-0" LONG X 9" THROAT. QUANTITY: YES❑ NOX ROOF FRAMED OPENINGS, SEE ROOF FRAMING PLAN FOR SIZES YES❑ NOX COMPOSITE CFR DECK, TYPE: N/A GAUGE: FINISH: WALL SHEETING TYPE: CW GAUGE: 26 FINISH: Fox Gray SP CORNER TRIM, PAINTED: Aztec Blue SP BASE TRIM, PAINTED: Fox Gray SP YESX NOD WALKDOORS, QUANTITY: (3) 3070 PAINTED: WHITE YES❑ NOX WINDOWS, QUANTITY: PAINTED: YESX NOD INSULATION 6 INCH (NOT BY MBS) WALL FRAMED OPENINGS YESX NO❑ FRAMED OPENING TRIM, PAINTED: Aztec Blue SP r 0ow ..U=C.17q ANUI LD/NS SYSTEMS A DMSION OF NUCOR CORPORATION MBMA M E M B E R SIZES: FSW: (2) 6'-0" x 3'-0", sill at 11'-6" SSW: (1) 4'-0" x 4'-0", sill at 3'-0" LEW: (1) 4'-0" x 4'-0", sill at 3'-0"; (1) 1W-0" x 14'-0" REW: none BUILDING OPTIONS YES( No❑ LINER PANELS FRAMED OPENING TRIM, PAINTED: Polar White SP WALL• TYPE: CL GAUGE: 26 FINISH: Polar White SP WALL TRIM, PAINTED: Polar White SP CEILING: TYPE: GAUGE: FINISH: YES❑ NOX TRANSLUCENT PANELS WALL: ROOF: INSULATED PANELS? YES❑ NO❑ YES❑ NOX EAVE EXTENSION PROJ: TYPE: GAUGE: FINISH: SOFFIT TRIM AT BUILDING LINE PAINTED: YES[-] NOX RAKE EXTENSION PROJ: TYPE: GAUGE: FINISH: SOFFIT TRIM AT BUILDING LINE PAINTED: YES[-] NOX CANOPY AT EAVE LINE ❑ BELOW EAVE ❑ PROJECTION: CLEAR UNDER CANOPY BEAM: ROOF PANEL: TYPE: _GAUGE, FINISH: SOFFIT PANEL: TYPE: _GAUGE, FINISH: SOFFIT TRIM AT BUILDING LINE PAINTED: YES❑ NOX PARTITION WALLS WALL PANEL: TYPE: _GAUGE, FINISH: TRIM PAINTED: YES❑ NOX WAINSCOT WALL PANEL, TYPE: _GAUGE, FINISH: BASE TRIM PAINTED: JAMB TRIM PAINTED: TRANSITION TRIM PAINTED: YES[-] NOX FASCIA PROJ: TOP OF FASCIA HEIGHT: FACE PANEL, TYPE: _GAUGE, FINISH: CAP TRIM PAINTED: BACK PANEL, TYPE: _GAUGE, FINISH: BASE TRIM PAINTED: ❑ CLOSED SYSTEM, CLEAR UNDER SOFFIT TRIM: SOFFIT PANEL, TYPE: _GAUGE, FINISH: SOFFIT TRIM AT BUILDING LINE PAINTED: ❑ OPEN SYSTEM, (NO SOFFIT PANEL PROVIDED) CLEAR UNDER SOFFIT TRIM: YES❑ NOX PARAPET ❑ STRUCTURAL PARAPET ❑ NON-STRUCTURAL PARAPET TOP OF PARAPET HEIGHT: BACK PANEL, TYPE: _GAUGE, FINISH: YES❑ NOX CRANES (SEE CRANE PLAN FOR ADDITIONAL INFORMATION) YES❑ NOX MEZZANINE (SEE MEZZANINE PLAN FOR ADDITIONAL INFORMATION) Digitally signed by Kevin THE DRAWINGS AND THE METAL BUILDING THEY REPRESENT ARE THE PRODUCT OF THE METAL BUILDING MANUFACTURER. THE REGISTERED PROFESSIONAL ENGINEER'S SEAL PERTAINS ONLY TO THE REQUIREMENTS LISTED HEREIN FOR THE MATERIALS DESIGNED AND SUPPLIED BY THE METAL BUILDING MANUFACTURER. THE REGISTERED PROFESSIONAL ENGINEER WHOSE SEAL APPEARS ON THESE DRAWINGS IS EMPLOYED OR ENGAGED BY THE METAL BUILDING MANUFACTURER AND DOES NOT SERVE AS OR REPRESENT THE PROJECT ENGINEER OF RECORD AND SHALL NOT BE CONSTRUED AS SUCH. 7.GLOSSARY OF ABBREVIATIONS: A.B. = ANCHOR BOLTS MAX = MAXIMUM REQ'D = REQUIRED BS = BOTH SIDES M.B. = MACHINE BOLTS REV. = REVISION B.U. = BUILT-UP MBS = METAL BUILDING SUPPLIER SIM = SIMILAR DIA = DIAMETER TBD = TO BE DETERMINED SL = STEEL LINE FLG = FLANGE N/A = NOT APPLICABLE N.S. = NEAR SIDE F.S = FAR SIDE NIC = NOT IN CONTRACT MIN = MINIMUM GA. = GAUGE SLV = SHORT LEG VERTICAL TYP = TYPICAL H.S.B. = HIGH STRENGTH BOLTS O.A.L. = OVERALL LENGTH PL = PLATE HT. = HEIGHT O.C. = ON CENTER LLV = LONG LEG VERTICAL U.N.O. = UNLESS NOTED OTHERWISE PEMB = PRE-ENGINEERED METAL BUILDING MANUFACTURER ?? = PART MARK TO BE DETERMINED AND WILL BE UPDATED ON CONSTRUCTION DRAWINGS Miketta DN: C=US, E= Kev i n. M i ketta @ n b s u t. co m, }+ O=Nucor, OU=NBGUT, Kevin M l ketta CN=Kevin Miketta Reason: I have reviewed this document Date: 2021.12.10 11:33:26-07'00' ACCREDITED" III �;ng Sistars BUILDING LOADS DESIGN CODE: IBC 18 ROOF LIVE LOAD: 20.00 PSF MBMA OCC. CLASS: II LIVE LOAD REDUCIBLE No GROUND SNOW LOAD: 50.0 PSF SNOW EXP. FACTOR, Ce:1.0000 SNOW IMPORTANCE FACTOR, Is: 1.00 100 YEAR RAINFALL INTENSITY (IN/HR): 4.00 WIND: 115 / 89 MPH ELEVATION: 4,500 FT (Vult) / (Vaed) C & C PRESSURES (PSF): 27 / -36 EXPOSURE: C UL 90 NO Classic Roof-Const. No.161 ; Classlc Roof w/ Translucent Panel-Const. No.167 CFR Roof-Const. No.552 ; CFR Roof w/ Translucent Panel-Const. No.590 Composite CFR Roof-Const. No.552A ; VR18 II Roof-Const. No.332 . SEISMIC INFORMATION Ss:0.365 S1:0.143 Design Sds/Sd1: 0.367 / 0.221 Site Class: D Seismic Imp. Factor: 1.00 Seismic Design Category: D Analysis Procedure: Equivalent Lateral Force Method Basic SFRS: Ordinary Steel Moment Frames do Ordinary Steel Conn - Braced Frames NOTES: 1) COLLATERAL DEAD LOADS, UNLESS OTHERWISE NOTED, ARE ASSUMED TO BE UNIFORMLY DISTRIBUTED. WHEN SUSPENDED SPRINKLER SYSTEMS, UGHnNG, HVAC EQUIPMENT, CEILINGS, ETC., ARE SUSPENDED FROM ROOF MEMBERS, CONSULT THE M.B.S. IF THESE CONCENTRATED LOADS EXCEED 500 POUNDS (USING THE WEB MOUNT DETAIL) OR 200 POUNDS (USING THE FLANGE MOUNT DETAIL), OR IF INDIVIDUAL MEMBERS ARE LOADED SIGNIFICANTLY MORE THAN OTHERS. 2) THE DESIGN OF STRUCTURAL MEMBERS SUPPORTING GRAVITY LOADS IS CONTROLLED BY THE MORE CRITICAL EFFECT OF ROOF LIVE LOAD OR ROOF SNOW LOAD, AS DETERMINED BY THE APPUCABLE CODE. 3) Pm IS BASED ON THE MINIMUM ROOF SNOW LOAD CALCULATED PER BUILDING CODE OR THE CONTRACT SPECIFIED SNOW LOAD, WHICHEVER IS GREATER. THIS VALUE, Pm, IS ONLY APPLIED IN COMBINATION WITH THE DEAD AND COLLATERAL LOADS. ROOF SNOW IN OTHER LOADING CONDITIONS IS DETERMINED PER THE SPECIFIED BUILDING CODE. BUILDING ROOF DEAD (PSF): 3.00 ROOF SNOW Pm (PSF): 20.00 PRI. COL (PSF): 1.00 WIND ENCLOSURE: Closed SEC. COL (PSF): 1.00 GC is ".18 SNOW Ct: 1.00 SEISMIC R: 3.25 SNOW Cs: 1.00 SEISMIC Cs: 0.113 ROOF SNOW Ps (PSF)- 35.00 BASE SHEAR (KIPS): 7.71 ERECTION MANUALS REQUIRED (ERECTION MANUALS ARE SHIPPED IN A WAREHOUSE PACKING CRATE) ❑ CFR ROOF ❑ H9700 OR ❑ H8260 10 SINGLE CURB (H9850) ® CLASSIC ROOF ® H9420 OR ❑ H8201 I0 DOUBLE CURB (H9800) ❑ VR16 II H9925 TRADEMARK 1998, NUCOR BUILDING SYSTEMS DRAWING INDEX COVERSHEET C1, C2. C3 ANCHOR BOLT DRAWINGS F1, F2 COLUMN BASE REACTIONS F2 STRUCTURAL/SHEETING DRAWINGS E7 - E7 DETAILS N 0 U n §a 0- 0 C) U) Z W 07 X W Of ~ Z (Y O w c � W Z� U C1) w �W a Z _O H W J W w w J W LLJ U) Q Q � M w �LU Z� Z) o - tam x - - - sM - O _�Em3 o- =Etc U m. E m rnu�or� RUILO/NQ SYSTEMS A DIVISION OF NUCOR CORPORATION m8mR M E M B E R ACCREDITED' YeEd Bi3p =/ehme � {72 STRUCTURAL OBSERVATIONS, TESTS, AND INSPECTION: 1) WHEN STRUCTURAL OBSERVATIONS ARE REQUIRED AS PER IBC 1704.6, OBSERVATIONS SHALL BE PERFORMED BY AN INDEPENDENT ENGINEERING AGENCY EMPLOYED BY THE ARCHITECT OR OWNER. 2) THE SPECIAL INSPECTOR'S DUTIES ARE AS DESCRIBED IN SPECIAL INSPECTION. THE SPECIAL INSPECTOR'S DUTIES ARE AS DESCRIBED IN IBC 1704.3 AND 3) ALL TESTS AND INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT TESTING AND INSPECTION AGENCY EMPLOYED BY THE OWNER OR ARCHITECT. 4) THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING THE TEST AND INSPECTION FIRM WITH A SCHEDULE TO FACILITATE THE PROPER COORDINATION OF 5) PORTIONS OF WORK REQUIRING SPECIAL INSPECTION: AGENCY RESPONSIBLE FOR INSPECTION AND TESTING TO BE NAMED BY OWNER LATER. A. STRUCTURAL STEEL: f Zsilltlel•7 WORK. YES NO N/A 1. MILL REPORTS AND IDENTIFICATION OF STEEL (AFFIDAVIT OF COMPLIANCE)................................................................................................................................ ❑ 0 ❑ 2. SAMPLING AND TESTING OF SPECIMENS........................................................................................................................................................................................ ❑ 0 ❑ B. WELDING: 1. ALL STRUCTURAL WELDING (INCLUDES DECKING AND WELDED STUDS), EXCEPT WELDING IN APPROVED SHOPS PER IBC 1704.2.2....................................... 0 El El ULTRASONIC TESTING OF FULL PENETRATION WELD CONNECTIONS AT MOMENT FRAMES, BRACED FRAMES, BEAM SPLICES, AND FIELD WELDS . .................... E]■ E]3. STRUCTURAL LIGHT GAGE METAL FRAME WELDING......................................................................................................................................................................... E]■ E]C. BOLTING: 1. HIGH STRENGTH BOLT A325SC AND A490SC (PRETENSION VERIFICATION)......................................................................................................................................... ■ ❑ ❑ 2. HIGH STRENGTH BOLT A325N AND A49OX (PER COVER SHEET NOTES)....................................................................................................................................... 0 ❑ ❑ 3. EXPANSION/ADHESIVE ANCHORS IN CONCRETE OR MASONRY...................................................................................................................................................... 0 ❑ ❑ FOR OCCUPANCY (RISK) CATEGORY I OR II, IBC PROVISIONS INDICATE THAT SINGLE -STORY BUILDINGS SHALL HAVE "NO DRIFT LIMTI PROVIDED THAT INTERIOR WALLS, PARTITIONS, CEILINGS, AND EXTERIOR WALL SYSTEMS HAVE BEEN DESIGNED TO ACCOMMODATE THE SEISMIC STORY DRIFTS. INTERIOR WALLS, PARTITIONS, CEILINGS, OR EXTERIOR WALL SYSTEMS NOT PROVIDED BY THE METAL BUILDING MANUFACTURER SHALL BE DESIGNED AND DETAILED BY OTHERS TO ACCOMMODATE THE SEISMIC STORY DRIFTS. SEISMIC DRIFT VALUES MAY BE OBTAINED FROM THE METAL BUILDING MANUFACTURER. ACCESSORIES (DOORS, WINDOWS, ETC.) NOT PROVIDED BY THE METAL BUILDING MANUFACTURER MUST BE DESIGNED AS "COMPONENTS AND CLADDING" IN ACCORDANCE WITH THE SPECIFI C WIND PROVISIONS OF THE REFERENCED BUILDING CODE DISPLAYED ON THE COVER PAGE OF THIS DRAWING PACKET. FRAMED OPENINGS HAVE BEEN DESIGNED TO SUPPORT WIND 81 LOAD NORMAL TO THE WALL BASED ON THE STANDARD BUILDING CODE CRITERIA. FRAMED OPENINGS HAVE NOT BEEN DESIGNED FOR ANY ADDITIONAL MOMENT OR CATENARY FORCES FROM THE DOOR. ANY CHANGE TO THE INFORMATION SHOWN HERE WILL REQUIRE AN ENGINEERING INVESTIGATION AND POSSIBLE BUILDING REINFORCEMENT. CWB CSSBI `+wB CERTIFIED CSA A660 U 0- 0 0 U) (D Z W U) co W 0� ~ Z O O w c M W z U W o W a F- U Z Z _O U W CC W J W W W Q J Z) w d w - tam x lH N m'UEmm`mam' ENLARGED DETAIL EAVE STIFFENER REFERENCE EAVE STIFFENER DETAIL FOR WELDS FG-5 �W SEE DETAIL A, FG-5 1SWOS 3SWS W#: RANGES FROM EWES TO EWES PER ENS. WP##: WELD SIZE PER ENG. FULL LENGTH FILLET NEAR SIDE OF WEB WITH 3" OF FILLET PAST INNER MOST HOLE IN FROM EACH FROM FLANGE ALONG THE OPPOSITE SIDE OF WEB. * THIS WELD TYPICAL FOR ALL FLANGE TO ENDPLATE WELDS SHOWN. i STANDARD WELDS AND LEGEND Thickest Mat. Joined Weld Thickest Mat. Joined Weld 7 FWS$- FI LLET WELD, ONE SI DE <1/2" FW3 <1/2" FW3 FILLET LEG NEAR SIDE WELD: FAR SIDE WELD: FWS$ <-3/4" FW-4 <3/4" FW-4 3 T� I I ` a t%6, FWS$ > 3/4" FW 5 > 3/4" FW 5 FG-5 5 s/1s" $FILLET "$FILLET FG-5 FWSd DETAIL "A" Perpendicular Knee Column See Weld Standard sheet for WPS description FG-5 PS9 Knee FG-5 WPS/ DETAIL "A" Typical Column See Weld Standard sheet for WPS description *WPS9 CJPI F.S. EE DETAIL - *FG 5 FWD# p- TVD CIVCI'1 BASE DETAIL See Weld Standard sheet for WPS description Base plate extension and anchor gists may vary. FG-5 > FWS4 FG-5 FWR# TVD r3IAIAIE:n See Weld Standard sheet for WPS descrption Thickest Mat. Joined Weld < 112" FW 3 <3/4" FW 4 > 3/4" FW 5 FG-5 FWS3 0 Typ. Flange Brace Clip F( FG-5 >1/4 4"-12" 1 /4 4" -12' Runway Beam Interior Wide Flange Fixed Base Plate Crane Stop F FWD4 G-5 FG-5 FWD4 Runway End SPECIAL DETAILS See Weld Standard sheet for WPS description TvD Stiffener Detail Section A -A Structural Column 2FR FWS4 W PS4 21"R FWS4 FG-5 FWS4 Pipe or Tube Column Structural Details See Weld Standard sheet for WPS description FWD$ -FILLET WELD, BOTH SIDES FILLET LEG 3 3/16" FWD$ a va" FwD$ oR � 5 5/16" FWD$ $ FILLET $ $FILLET FWR -Full length fillet on near side with *(Max. D/5 or 3") fillet return at both ends on opposite side of plate. 3 FIL3E 6' FWR$ $ 41 1/4" OR � $ 5 5/16" *(M-13/5 or3) J WP1$ - Full length fillet on near side of web with 3" of fillet past inner most hole in from each flange along the opposite side of web. FILLET LEG yypl$ $ ORa 1/a" W%P1$ $5 5/16" 'no°� INFRom--LGE33/16" 1.0 CJP1 - COMPLETE JOINT PENETRATION, SINGLE BEVEL WELD NEAR SIDE WELD: FAR SIDE WELD: CJPI or /'<BACK GOUGE CJPI CJP2 GRoovOivEi� soueaE --BACK GOUGE (GRIND FwsH-mP 0 45° BEVEL SIDE caoov BEVEL PURLIN / GIRT / CHANNEL EAVE STRUT QTY SHAPE OTY SHAPE SLOPE �(2 08C060 (2) 8E2075 Y THICKNESS Y THICKNESS i X J X SIZE 1000 SIZE 1000 X X XXXX X X X X X X X X X X X I X I X X1Xj X 1XIX X I X 1XI X X I X 1XI X X I X o U U CID X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X J C Z X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X ZD X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X R,- - - F 4. " E�E 0 0 0 0 id. I RI 16 16I l6 16^I I 76 n6^I 21 76^I o 0 0 0 _ II 11 TY - iy _ _ - Sy - iy _ _ - - it N N 0 0 U' ¢ 0 U' Q U LL N LL N U' LL m F F IV Q IV CE IV CE IV Tr IV Tr IV Fr IV IV CE IN M IV CE IN Q IV CE O CE O M �F O G= LL LL 0 S 0 S O S O S O S O S O S O S O S O S O S O S Preq OL 0- 0 DIDU) L, L,Lu V) ao= 0-0= a0-Q 0-0= ao= OQ OL ao= aa0-o= Q a 0- 0 U LU Lu Z W DAD W w C/) X J EIE Z W Li LL1 Of - cr- Z c Q $ 3 o W U Ln Cn Cl) o_ _ it m a a a a >' _- ao 3 m - y u u 3 A .� 3 8 o 8 a w (� ¢ z W S Q z c CO (� o' uv - 8 DID- 3 no - 3 - o a u d d i° V U V_ " 8 - S -_ m m U" w 10�t o w G_ O I— W � 3= d an as �- n ¢° �� �� o m a_ E LL z a¢ _. 3 3 3 3 $ $ o W u~i _J of z N DO ED. F- 0 3:0 a a a a Ills a a a a a a a a a a a a a a s a a a a a a s a a a s a a or m m -o r"n 3 3 3 3. ^-' n = 3 O O O O a O O N -aN -pN Or, i >i -O N G, N N N.L.. NS > c �C O- mREo o > aoro> ED n NL o_' n mt o= n om �s o; so ms o= a m°o 3�� ro°o 3��N 0 o s E D. EN m N o a ro cN cAl -a cn1N '� o 3 a_I sa 3. U _ m m `� w co w o m m `o� m o om 0 `o in N o `oo n a ° 0 ro m 0 in `o l� m o `oo n E ro m �'o 3�m �'O ° um 3o�m m N ro E ro� N ro > N Eor E o LL d - 3 aN> N mmm 30 o 0 m o> oro N oro o" N m oro> o -- ro� ro - ro o ° uo $o $o �o �o o�m Qo LL LL a o E E �_ m .0 �r mt'o' Mo -ary a a a o. n a �- �- ro 0 3 o a+.. ro 3 o m� 0 N > -o -o O c) -LLo ti cYi ._ E� E E a E p ED E p -o O E - E oAl E$'Z�pa m m m o ¢° a a `m m' mm N-`o '� 0 0 - i� = E o o 0 oy o" 0 a s�i;��oazd� - » $ M E 0 0 �� -0 O -b 0 -o 0 -o o 0.- -o o o.- a aN o om ---25 =�8m (O 0 co Cn 0 � 7 V Do GO r W CS) T — ,� N N M A � V L9 Do � Crop 11 fro a Ec Nm CE, P3��F'a"o Ed m Amy oa$r3�y Na U cD o LL m Cn o n D_ cn a n d n a (n p- o- aa. cis a cn a cn a ch a ch a. 0 a. cn weal d w� W °=oos w L.L C7 C7 N C7 M N (7 u7 u) Cn N Cn c•J N N LL �i � � � � � 2 2- 2rnRe � � � � r E -0" -0" O Diu- 3/4" \rJ 0f1'—f1" NR 7PLNR AC aTm 5 High E. 2 3 4 22'-6" 22'-6" 22•-6" 22'-6" 3'-0" 4'-0" 15'-6" X-Bracing rr, i e o e o o e Sri-102'—o• ro7, 1 U n rH, B L° J Ekh-102'-0- L-3 EMi-,02'-0- r yI BLHJ n role ol,B 0.Y-102'-0- L J 0 0 CT o I C I o o I Eki-102'-0• o 0 LHJ Eh-102'-0- L: j X-Bracing 22'-6" 22'-6" 22'-6" 22'-6" CDI CDI 6 T PLAN Nd1ANCHOR Pkdu o for -W (U.N.) C1 bLow Eaw i A E I ANCHOR BOLT SUMMARY Qty Locate (in) Type p(in) 028 Endwall 3/4" F7554 3.00 024 Frame 3/4" F1554 3.00 ANCHOR BOLT PLAN GENERAL NOTES THE SPECIFIED ANCHOR ROD DIAMETER ASSUMES F1554 GRADE 55 UNLESS NOTED OTHERWISE. ANCHOR ROD MATERIAL OF EQUAL DIAMETER MEETING OR EXCEEDING THE STRENGTH REQUIREMENTS SET FORTH ON THESE DRAWINGS MAY BE UTILIZED AT THE DISCRETION OF THE FOUNDATION DESIGN ENGINEER. ANCHOR ROD EMBED- MENT LENGTH SHALL BE DETERMINED BY THE FOUNDATION DESIGN ENGINEER. 2. METAL BUILDING MANUFACTURER IS NOT RESPONSIBLE FOR PROJECT FOUNDATION DESIGN. THE FOUNDATION DESIGN IS THE RESPONSIBILITY OF A REGISTERED PROFESSIONAL ENGINEER, FAMILIAR WITH LOCAL SITE CONDITIONS. 3. ANCHOR RODS, NUTS, FLAT WASHERS FOR ANCHOR RODS, EXPANSION BOLTS, AND CONCRETE/MASONRY EMBEDMENT PLATES ARE NOT BY METAL BUILDING MANUFACTURER. 4. THE ANCHOR ROD LOCATIONS PROVIDED BY METAL BUILDING MANUFACTURER SATISFY PERTINENT REQUIREMENTS FOR THE DESIGN OF THE MATERIALS SUPPLIED BY THE METAL BUILDING MANUFACTURER. IT IS THE RESPONSIBILITY OF THE FOUNDATION ENGINEER TO MAKE CERTAIN THAT SUFFICIENT EDGE DISTANCE IS PROVIDED FOR ALL ANCHOR RODS IN THE DETAILS OF THE FOUNDATION DESIGN. 5. DRAWINGS ARE NOT TO SCALE. SEE DETAILS FOR COLUMN ORIENTATION. 6. THE ANCHOR ROD PLAN INDICATES WHERE THE ANCHOR RODS ARE TO BE PLACED AS WELL AS THE FOOTPRINT OF THE METAL BUILDING. IT IS ESSENTIAL THAT THESE ANCHOR ROD PATTERNS BE FOLLOWED. IF THESE SETTINGS DIFFER FROM THE ARCHITECTURAL FOUNDATION PLANS, THE METAL BUILDING MANUFACTURER MUST BE CONTACTED IMMEDIATELY - BEFORE CONCRETE IS PLACED. 7. "SINGLE" CEE COLUMNS SHALL BE ORIENTED WITH THE "TOES" TOWARD THE LOW EAVE UNLESS NOTED OTHERWISE. 8. ALL DIMENSIONS ARE OUT TO OUT OF STEEL. IF CONCRETE NOTCH IS REQUIRED THEN THE REQUIRED DIMENSION SHOULD BE ADDED TO OBTAIN THE OUT TO OUT OF CONTRETE DIMENSIONS. 9. FINISHED FLOOR ELEVATION = 100'-0" BOTTOM OF BASE PLATE = 100•-0" UNLESS NOTED OTHERWISE. N C O U 0- 0 Oo H OfU J W r Z W pp W w Z W LLI Z — Lo w Ln w >- c') Q Q coz W w w�X m� w o W o LWL J m N d w tam x E�oo t.5- to -a3o- -Et 0 Ed _a�H3�rn Nv LL E. -T- Olr@ 9� 4 OIO I 3" 00 0 10 3 1/2" 1" L 1 1/2 1 1/2" 1r-4 DETAIL A Base EL. 102'-0" Oda 010 1 3» a0 010 1" 1 1/2" 1 1/2" See Plan DETAIL B Base EL. 102'-0" 010 0 1 3" 010 3 1/2„ 1 1/2L 1 1/2"1 $ See Plan DETAIL C -T- 00 010 o 1 3" 010 - 1 - 3 1/2" 1 J-4 1 /2" $ See Plan DETAIL D EWI F401 LINE RIGID FRAME: mom emus s ow mA m Frm Col Anc._Bolt Base -Plate (in) Elev. Line Line City Dia Width Length "thick (in) 2* A 4 0.750 8.000 12.63 0.375 0.0 2* E 4 0.750 8.000 12.56 0.375 0.0 2* Frame lines: 2 3 4 ENDWALL COLUMN: ANCHOR Balls s al►9E nam Frm Col Anc._Bolt Base -Plate (in l Elev. Line Line City ViaWidth length "Thick (in) 1 A 4 0.750 8.000 8.250 0.375 24.0 1 B 4 0.750 8.000 8.250 0.375 24.0 1 D 4 0.750 8.000 8.250 0.375 24.0 1 E 4 0.750 8.000 8.250 0.375 24.0 5 E 4 0.750 8.000 8.250 0.375 24.0 5 C 4 0.750 8.000 8.250 0.375 24.0 5 A 4 0.750 8.000 8.250 0.375 24.0 GENERAL NOTES 1 REACTIONSGCONDITIONS ARE AND THE CORRESPONDINGD. THE VERTICAL MAXIMUM) OR HORIZONTAL4HORIZONTAL(H) REACTIONS ARENVERTICAL (V) REPORTED. 2. REACTIONS ARE PROVIDED BY LOAD CASE IN ORDER TO AID THE FOUNDATION ENGINEER IN DETERMINING THE APPROPRIATE LOAD FACTORS AND COMBINATIONS TO BE USED WTIH EITHER WORKING STRESS OR ULTIMATE STRENGTH DESIGN METHODS. WIND LOAD CASES ARE GIVEN FOR EACH PRIMARY WIND DIRECTION. 3. FOR ASCE7-10 AND LATER BASED BUILDING CODES, THE UNFACTORED LOAD CASE REACTIONS DUE TO WIND ARE GENERATED USING THE ULTIMATE DESIGN WIND SPEED (Vult). 4. POSITIVE (+) REACTIONS ARE AS SHOWN ABOVE. FOUNDATION LOADS ARE IN OPPOSITE DIRECTIONS. 5. BRACING REACTIONS ARE IN THE PLANE OF THE BRACE FROM THE BRACED BAY AND THE VERTICAL REACTION () L REACTION (H) ACTING AWAY ACTING DOWNWARD. ****** RIGID FRAME LOAD CASE ABBREVIATIONS: ****** Wind_Ll/Wind_R1: LATERAL WIND FROM THE LEFFTRIGHT, CASE 1 Wind_L2/Wind_R2: LATERAL WIND FROM THE LEFFTT/RIGHT, CASE 2 Wind_Lnl/Wind_Ln2: LONGITUDINAL WIND, CASE 1 2 Seismic _L Seismic R: LATERAL SEISMIC LOAD FR M LEFT/RIGHT LWIND#_L E/LWIND _R#E: LONGITUDINAL WIND EDGE ZONES Fi�UNB_SLL F#UN _SLR: UNBALANCED ROOF SNOW WITH WIND FROM LEFT/RIGHT F PAT_LL #//F AT_SL #: PARTIAL LIVE/SNOW LOADING FOR CONTINUOUS BEAM SYSTEMS ****** ENDWALL COLUMN LOAD CASE ABBREVIATIONS: ****** Collat: COLLATERAL LOAD Rafter Wind_L/Rafter Wind_R: LATERAL WIND FROM THE LEFT/RIGHT Brace Wind_L/Brace Wind_R: LATERAL WIND FROM THE LEFT/RIGHT Wind_P/Wind_S: LONGITUDINAL WIND PRESSURE/SUCTION ON COLUMNS Wind_Ln: LONGITUDINAL WIND SUCTION ON ROOF Seis_L/Seis_R: LATERAL SEISMIC LOAD FROM LEFT/RIGHT E UNB_SL_L/E UNB_SLR: UNBALANCED ROOF SNOW WITH WIND FROM LEFT/RIGHT E PAT_LL #/E PAT_SL #: PARTIAL LIVE/SNOW LOADING FOR CONTINUOUS BEAM SYSTEMS TYPICAL COLUMN BASE PLATE DETAIL O 2 COLUMN FINISH FLOOR ANCHOR BOLT TYPICAL COLUMN BASE PLATE DETAIL RIGID FRAME: a11w coluuw LiEAC110N8 pk ) Frame Column -----Dead-----Collateral- ----- Live --------- Snow-----Wind_Leftl- -Wind-Rightl- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 2* A 0.9 2.6 0.2 0.6 4.7 11.4 8.2 20.0 -7.1 -9.5 1.2 -8.2 2* E -0.9 2.4 -0.2 0.6 -4.7 11.3 -8.2 19.7 -3.2 -3.8 8.8 -12.8 Frame Column--Wind-Left2- -Wind- --Wind-LLon- --Wind_Long2- -Seismic eft Seismic -Right line line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 2* A -6.9 -5.1 1.0 -3.9 0.0 -6.6 -1.9 -10.7 -2.3 -1.9 2.3 1.9 2* E -3.5 0.5 9.1 -8.4 0.2 -6.7 1.4 -10.3 -2.8 1.9 2.8 -1.9 Frame Column-MIN_SNOW-- Line Line Horiz Vert 2* A 4.7 11.4 2* E -4.7 11.3 2* Frame lines: 2 3 4 ENDWALL COLUMN: am omww RIaIam (k ) Wind Wind Wind Wind Wind Wind Wind Wind Frm Col Dead Collat Live Snow Leftl Rightt Left2 Right2 Press Suct Long1 Long2 Line Line Vert Vert Vert Vert Vert Vert Vert Vert Harz Harz Vert Vert 1 A 0.4 0.1 1.2 2.2 -1.0 -1.5 -0.6 -1.1 -1.3 1.4 -0.7 -1.4 1 B 1.1 0.2 4.5 8.0 -3.2 -5.5 -1.4 -3.7 -2.7 2.9 -3.2 -5.5 1 D 1.0 0.2 4.5 8.0 -3.2 -5.5 -1.5 -3.8 -2.4 2.6 -3.2 -5.5 1 E 0.4 0.1 1.2 2.1 -0.7 -1.4 -0.2 -0.8 -1.0 1.1 -0.9 -1.5 Seis Seis Frm Col Left Right -MIN_SNOW-- E1 PAT_SL_t - Et PAT_SL_2- Et PAT_SL_3- E1 PAT_SL_4- Line Line Vert Vert Harz Vert Harz Vert Harz Vert Harz Vert Harz Vert 1 A 0.0 -0.1 0.0 1.2 0.0 1.4 0.0 0.0 0.0 1.0 0.0 -0.3 1 B 0.0 0.0 0.0 4.6 0.0 1.7 0.0 -0.2 0.0 4.2 0.0 2.3 1 D 0.0 0.0 0.0 4.6 0.0 -0.2 0.0 1.7 0.0 2.3 0.0 4.2 1 E 0.1 0.0 0.0 1.2 0.0 0.0 0.0 1.4 0.0 -0.3 0.0 1.0 Wind Wind Wind Wind Wind Wind Wind Wind Fnm Col Dead Collat Live Snow Left1 Rightl Left2 Right2 Press Suct Long1 Long2 Line Line Vert Vert Vert Vert Vert Vert Vert Vert Horz Harz Vert Vert 5 E 0.6 0.1 2.3 3.9 -2.6 -1.5 -1.7 -0.5 -1.6 1.8 -1.7 -2.8 5 C 1.6 0.4 7.0 12.3 -8.7 -5.0 -6.0 -2.3 -3.5 3.8 -5.0 -8.5 5 A 0.7 0.1 2.3 4.0 -2.6 -1.6 -1.8 -0.9 -2.1 2.3 -1.5 -2.6 Seis Sets Frm Col Left Right -MIN_SNOW--E2PAT_SL_1- E2PAT_SL_2- Line Line Vert Vert Horz Vert Harz Vert Harz Vert 5 E 0.0 0.1 0.0 2.3 0.0 2.3 0.0 -0.3 5 C 0.0 -0.1 0.0 7.0 0.0 3.1 0.0 3.1 5 A 0.0 0.0 0.0 2.2 0.0 -0.3 0.0 2.3 BUILDING BRACING REACTIONS f Reactions k ) Panel Shear -Wall - Col -Wind - - eismic- (lb]ft) Lac Line Line Harz Vert Harz Vert Wind Seis Note L_Ew 1 ------ (-) F_SW E 2,3 3.7 2.5 4.0 2.6 R_EW 5 EC 2.9 1.9 1.2 0.8 B_SW A 3,2 4.0 3.4 4.1 3.4 (i)Bracing in roof to rigid frame FOUNDATION DESIGN NOTES: 1. THE ORIENTATION OF THE ANCHOR BOLT DETAILS SHOWN ON THIS PAGE MAY NOT COINCIDE WITH THE ACTUAL COLUMN ORIENTATION SHOWN ON THE ANCHOR BOLT DRAWING. PLEASE REFERENCE THE SIDEWALL (SW) AND ENDWALL (EW) STEEL LINES SHOWN ON THE ANCHOR BOLT DETAILS WITH THE ANCHOR BOLT PLAN DURING LAYOUT OF COLUMN AND ANCHOR BOLT LOCATIONS. 2. COLUMN BASE PLATES MAY HAVE MORE HOLES THAN ARE REQUIRED DUE TO PRODUCTION LIMITATIONS. PLEASE FOLLOW ANCHOR BOLT DETAILS FOR QUANTITY OF ANCHOR BOLTS REQUIRED. EXTRA BASE PLATE HOLES DO NOT NEED INFILLED PER THE MBS DESIGN SPECIFICATIONS. A 2" CLR. OPENING ,�-i VARIES: 2}"-3j" (USE 2) 1/2" DIA EXPANSION OLTS PER COLUMN) GIRT DEPTH + 2" (RECOMMENDED) TYPICAL OVERHEAD DOOR FRAMED OPENING N C U 2A§& 3LL>3�� O Q _0 U J Of LU Z W LU IYi LU w Z LU W LU Of UJ Z LfD w � Q' In w M Q Q co z LLI w w�Lo LU o LLLU J m N d r U '_ N =�3V m - �F - - 0 !E -Etc 11 _a�H3�rn Nv LL -2 m3a 8m'UEm I 4 I 4 O K N O N I 4 PURLIN LAP go'-o" our -TO -Our OF SrE>EL P-1 P-2 P-3 T RF1-2 P-4 T c ER-1 �6 `s F1-2 RF1-2 ER-4 RF1-3 ER-2 RF1-3 RF1-3 ER-3 t-1 Kr t-Z 3f 3 -0' Kr t-Z 1� �7 1-7- ROOF FRAMING PLAN Kr 1-* t-) 3'f 3 -0' MEMBER TABLE ROOF PLAN MARK PART I LENGTH P-1 95ZO67 305.750 P-2 95ZO67 325.000 P-3 95ZO67 325.000 P-4 95ZO67 305.750 E-1 95EO60 269.625 E-2 95EO60 269.750 E-3 95EO60 269.625 E-4 95HE060 269.625 E-5 95HE060 269.750 E-6 95HE060 269.625 CB-5 RD05— 308.000 CB-6 RD05— 314.000 CB-7 RD05— 298.000 I W N 0 U U Z Z N O Q Mc = U U) (D Lu Z W Of Lu Lu pp w Z Lu LJLI Lu Of LU 0 W z c ROOF FRAMING PLAN C5 w(D Lo w Lm Ea" ROOF GENERAL NOTES z>_ w a 00 w SHEETING PANELS: 20 Gm CR 1. PLACE TAGGED END OF RAFTERS TOWARDS THE LOW EAVE. w o Lu o Lu J z fl GalMduro PIw 2. STD. ROD/CABLE SIZES PER PART PREFIX ARE: a Z) o ROD CABLE RD05- = 5/8" ROD CA02- = 1/4" CABLE RD06- = 3/4" ROD CA03- = 3/8" CABLE RD07- = 7/8" ROD CA04- = 1/2" CABLE RD08- = 1" ROD RD09- = 1 1/8" ROD RD10- = 1 1/4" ROD 3. PURLIN AND EAVE STRUT CONNECTIONS UTILIZE BOTH A307 AND A325 BOLTS. REFER TO THE DETAILS FOR SPECIFIC USAGE REQUIREMENTS. 4. THIS DRAWING IS NOT TO SCALE. = t m = E�oo -- - n O a�H3�rn Nv w -_=n�vE �3aoagiy m'UEmm `mam'm�m N M N M N N 33 U U N CONNECTION PLATES 0 w d ❑ ID Mark Part o 1 FBL&N01 0 t 4'-7" 289.00" 22 0 � v OFF cLi d� m' 4'-9" 300.25" 4" 7 8 ® 4'-10" 'j1/j i bS W FBC38A 2 4'-9" 1 � 12 z� '�' �n5•. -®() FBC32A(1) h FBC32A(l) FBC32A(1) ®� FBC®(1) PA < 8 ^ 1118 FBC34A(2 )a ur N RF1-2 di 8 c W ilO = �� gam' N a RF1-3 N N �® to ®� M N7 U m O pUp li I N o O I � C IIN fl .-. I rn+ n O ® � m i� �U N I m cow m 16 Z Z O Oo � � w J Z r w m w w Z LLI LL] LLI � L1J " 2'-4 5/8" 42'-0 13/16" 2'-2 9/16" Z 0 CLEAR + - w w c') z LLI Q Q M w w�X m� 48'-0" OUT -TO -OUT OF STEEL Lc o LI vo~ J Z d U A E RIGID FRAME ELEVATION: FRAME LINE 2 3 4 GENERAL NOTES 1. � INDICATES FLANGE BRACING LOCATIONS. (1) = ONE SIDE; (2) = TWO SIDES. 2. IF FLANGE BRACING IS REQUIRED ON BOTH SIDES OF AN EXPANDABLE RIGID FRAME, THE OPPOSITE SIDE FLANGE BRACES WILL HAVE TO BE INSTALLED AT THE TIME OF FUTURE EXPANSION. THESE FLANGE BRACES HAVE BEEN PROVIDED, AS REQUIRED, FOR THIS FUTURE CONDITION. 3. RIGID FRAMES SHALL HAVE 50% OF THEIR BOLTS INSTALLED AND TIGHTENED ON BOTH _ w SIDES OF THE WEB ADJACENT TO EACH FLANGE BEFORE THE HOISTING EQUIPMENT IS = .15 m« E �6adv�oo�� w to RELEASED. - ���d�z oso ti 4. INTERIOR COLUMN METAL TAG IS ORIENTED TOWARD THE LOW EAVE OF THE BUILDING. 04 -_=n�vE �3aoagiy m'UEmm `mam'm�m SPLICE PLATE & BOLT TABLE Qty Mark To Bot Int Type Dia Length Width Thick Length SP-1 4 4 0 A325 0.750 3.00 8" 5/8 2-11 3/4;; SP-2 4 4 0 A325 0.625 2.25 5" 3/8 1'- 10 1 4 SP-3 6 6 0 A325 0.750 3.00 8" 5/8" 2'-5 3 4" MEMBER TABLE Web De th Web Plate Outside Flange Inside Flange Mark W x Thk x Len th W x Thk x Len th Start End Thick Length RF1-1 12.0 28.0 0.135 206.7 5 x 1/4" x 241.0 5 x 3/8" x 207.3 28.0/28.0 0.220 34.3 8 x 3/8" x 36.1 RF1-2 28.0/16.0 0.135 105.5 5 x 5/16" x 105.5 5 x 5/16" x 103.9 16.0/16.0 0.135 287.6 5 x 3/8' x 287.6 5 x 1/4 x 287.E RF1-3 16.0/22.0 0.135 1 12.7 5 x 5/16" x 1 10.8 5 x 5/16" x 1 12.8 RF1-4 26.0/26.0 0.220 25.9 8 x 3/8" x 34.1 5 x 5/16" x 171.3 26.0 12.0 0.135 170.7 5 x 1 4" x 194.4 co 0 co 90'-0" our-i0-our of srm _ -1 _ G-10 DH -1 0 n G-7 G-8 G-8 171 G-11 21 10: �s a --- — EC-4 RF1-4 RF1-4 RF1-4 EC-5 �- 8'-3" I 6 -0" I 8 -3" I 8 -3" 6'-0" GIRT t+ , V7,3 t'-3 LAPS 1 -3 '_3- 1-3' SIDEWALL FRAMING: FRAME LINE E I T T I s p a 00 s u s — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1 — — — — — — — — — — — — — — — — — — — — —9 — t t 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 SIDEWALL SHEETING & TRIM: FRAME UNE E PANELS: 26 ft CW - Foot 0rcV SIR TRIM FRAME TABLE LINE E *ID PART LENGTH DETAIL 1 OCA01 242.000 TRIM_? 2 MFB01 121.000 TRIM-7 3 BSC01 122.000 TRIM_722 4 SET01 121.000 TRIM_850 5 CTA03 121.000 TRIM_850 6 H4000 5.000 7 ERA01 8.060 8 RCA01 9.250 9 RCA02 9.250 10 CCA121 121.000 TRIM_19 11 JTA087 87.000 TRIM_99 12 CCA121 Use Drop TRIM_19 14 HTA080 80.000 TRIM_99 15 STA076 76.000 TRIM_99 MEMBER TABLE FRAME LINE E MARK PART LENGTH DJ-3 J08CO60 103.000 DH-1 J08CO60 72.000 DS-2 J08CO60 72.000 E-1 95EO60 269.625 E-2 95EO60 269.750 E-3 95EO60 269.625 G-7 08ZO54 284.750 G-8 08ZO54 300.000 G-9 08ZO54 111.000 G-10 08ZO54 111.000 G-11 08ZO54 284.750 CB-3 I RD05— 333.000 CONNECTION PLATES FRAME LINE E ❑ID MARK PART 1 1 JCE01 2 GCC03 SIDEWALL FRAMING PLAN GENERAL NOTES 1. STD. ROD/CABLE SIZES PER PART PREFIX ARE: ROD CABLE RD05- = 5/8" ROD CA02- = 1/4" CABLE RD06- = 3/4" ROD CA03- = 3/8" CABLE RD07- = 7/8" ROD CA04- = 1/2" CABLE RD08- = 1" ROD RD09- = 1 1/8" ROD RD10- = 1 1/4" ROD 2. ROD/CABLE BRACING THAT OCCURS IN FLUSH OR INSET GIRT CONDITIONS WILL REQUIRE FIELD SLOTTING OF GIRT WEBS TO ALLOW FOR BRACING. 3. FRAMED OPENINGS WHICH ARE FIELD LOCATED WILL REQUIRE FIELD CUTTING OF GIRTS AND SHEETING. 4. THIS DRAWING IS NOT TO SCALE. N 0 U 0- 0 Q U J U) � w r Z Of W W 00 Lu w Z Lu LJLI 0)w-a w c') Q Q M z LLI w r- �� w� �oH LLI oWL d w - tam x O a�H3�rn Nv LLI �3amdym'UEmm`mam' 90'-0" our-70-our OF SMM J8 G-7 G-8 G-8 G-11 LL G-8 XG-8 G-11 G-7 G-8 - 3 a — — — — — — — — — — — — — — — — — I — — — — — — — — — — — — — — — — — — — — 3 -0" — rl- L— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J H 2 2 2 ] C H EC-7 RF1-1 RF1-1 RF1-1 EC-1 15'-6" 4'-0" 3'-0"_� GIRT LAPS SIDEWALL FRAMING: FRAME LINE A I I I I I o ° g 0 0 0 0 0 o c o 0 0 0 0 0 o c o 0 0 0 0 0 o c o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N 1 1 1 1 , s L3------------------------------------------------------J SIDEWALL SHEETING & TRIM: FRAME UNE A PMa& 28 Gm OW - Foot GnoDr SP TRIM FRAME TABLE LINE A *ID PART LENGTH DETAIL 1 OCAO1 242.000 TRIM_? 2 MFBO1 121.000 TRIM-7 3 BSCO1 122.000 TRIM_722 4 HEAO2 242.000 TRIM-6 5 H4OOO 5.000 6 CCA121 121.000 TRIM-19 10 CCA121 Use Drop TRIM-19 11 JTAO87 87.000 TRIM_99 12 CCEO52 52.000 TRIM_19 13 HTAO8O 80.000 TRIM_99 14 STAO76 76.000 TRIM 99 MEMBER TABLE FRAME LINE A MARK PART LENGTH DJ-1 JO8CO6O 66.000 DS-1 JO8CO6O 48.000 E-4 95HEO6O 269.625 E-5 95HEO6O 269.750 E-6 95HEO6O 269.625 G-7 O8ZO54 284.750 G-8 O8ZO54 300.000 G-11 O8ZO54 284.750 CB-4 RDOS— 361.000 CONNECTION PLATES FRAME LINE A ❑ID I MARK PART 1 1 GCCO SIDEWALL FRAMING PLAN GENERAL NOTES 1. STD. ROD/CABLE SIZES PER PART PREFIX ARE: ROD CABLE RD05- = 5/8" ROD CA02- = 1/4" CABLE RD06- = 3/4" ROD CA03- = 3/8" CABLE RD07- = 7/8" ROD CA04- = 1/2" CABLE RD08- = 1" ROD RD09- = 1 1/8" ROD RD10- = 1 1/4" ROD 2. ROD/CABLE BRACING THAT OCCURS IN FLUSH OR INSET GIRT CONDITIONS WILL REQUIRE FIELD SLOTTING OF GIRT WEBS TO ALLOW FOR BRACING. 3. FRAMED OPENINGS WHICH ARE FIELD LOCATED WILL REQUIRE FIELD CUTTING OF GIRTS AND SHEETING. 4. THIS DRAWING IS NOT TO SCALE. N U 00 0 U J U) (D Lu r Z W m LLI w Z Lu LJLI �Z Tn- 0�wLuo w c') Q Q M Z Ltd w r- �� w�X m� w� �oH LLI oLWL d r U d w - tam x O a�H3�rn Nv LLI -_=n�vE �3amdy m'UEmm`mam' N M N M N N 33 A E 48'-o"our-lo-air of srm g g U U B D m m 14'-0" 20'-0" 14'-0" 1 "� o d MAR01 0 — — ED 1 } tL — — — — � 0 m -- a -- rn �ER-2 -- -- G-1 JB-1 d` m' 0 N JB_2 I I M I 2 G-3 1'-6" — • • — LI— 1'-6" a N O W o I N I Ir Isto a I� � � ca n [�I G-1 N O N• G-1 L P o o �g�dc G Nut" N N I WDS-1 ^ @— _g �— ------- I — — — — — — — — — --------- 7 C I 7 C I ---_ EC-1 EC-2 EC-3 EC-4 ]2,1 4'-6" 4'-0" 5'-6" 2'—Ol 16'-0" ENDWALL FRAMING: FRAME LINE 1 1 z 12 _ CONNECTION PLATES O — — — FRAME LINE 1 O Q — — _ ❑ID MARK PART = � 0 o b o — — — 1 GCCO Z Of LU 0 N LO L 0 2 JCS01 w= w w o to c6 M LO m � w NLO O Z W W W Of W 1 1 z 7 iD n O O ,� z O N cn � 0 2 ENDWALL FRAMING PLAN C M N N N N 1 1 0 w ¢ Q<� z (6 1 ao GENERAL NOTES W F m w �_ X w m 1. STD. ROD/CABLE SIZES PER PART PREFIX ARE: o Lu W m CV s ROD CABLE RD05— = 5/8" ROD CA02— = 1/4" CABLE s $ RD06— = 3/4" ROD CA03— = 3/8" CABLE e RD07— = 7/8" ROD CA04— = 1/2" CABLE RD08— = 1" ROD Li s RDO9— = 1 1/8" ROD — — — — — RD10— = 1 1/4" ROD ENDWALL SHEETING & TRIM: FRAME LINE 1 2. ROD/CABLE BRACING THAT OCCURS IN FLUSH OR PANELS: 28 Gm CYI — FaX � SP INSET GIRT CONDITIONS WILL REQUIRE FIELD SLOTTING OF GIRT WEBS TO ALLOW FOR BRACING. 3. FRAMED OPENINGS WHICH ARE FIELD LOCATED WILL REQUIRE FIELD CUTTING OF GIRTS AND SHEETING. E� 7S -- - n 4. THIS DRAWING IS NOT TO SCALE. O LO W �3aoagiy m'UEmm `mam'm�m BOLT TABLE FRAME LINE 1 LOCATION UAN TYPE DIA LENGTH ER-1/ER-2 4 A325 1/2" 2 Columns Raf 4 A325 1 2" 2" TRIM FRAME TABLE LINE 1 *ID PART LENGTH DETAIL 1 OCA01 242.000 2 MF601 121.000 TRIM_? 3 BSC01 122.000 TRIM_722 4 RTA01 121.000 TRIM-2 5 RTA02 242.000 TRIM-2 6 CCA121 121.000 TRIM_19 7 JTA087 87.000 TRIM_99 8 CCA121 Use Drop TRIM-1 9 CCE052 52.000 TRIM_19 10 HTA080 80.000 TRIM_99 11 STA076 76.000 TRIM_99 12 CCA145 145.000 TRIM_19 13 JTA145 145.000 TRIM_98 14 CCA193 193.000 TRIM-1 15 HTA196 196.000 TRIM 98 MEMBER TABLE FRAME LINE 1 MARK PART LENGTH EC-1 W8x 10 209.375 EC-2 W8x10 196.688 EC-3 W8x10 176.688 EC-4 W8x10 164.063 ER-1 W8x10 223.313 ER-2 W8x10 353.563 DJ-1 J08C060 66.000 DJ-2 J08C060 144.000 DS-1 J08C060 48.000 G-1 08Z054 139.000 G-2 08Z054 14.500 G-3 08C060 227.000 JB-1 J08C060 46.250 JB-2 J08C060 30.250 FLANGE BRACE TABLE FRAME LINE 1 � ID SIDES MARK CLIP 1 1 FBC30 FBL&N01 N N M M N N 33 E A 48'-o"our-lo-air of srm g g U U c CD m 24'-0" 24'-0" U 121" w d s MpR01 ERI4 a Fa_ — — — m ERI3 — — — — — 14'-9 9/16" o rn C �o m 9 9 16" G-6 �_ 3'-8 7/16" _6il�W m� - 1^"s� o `Xa In I In N `316i �3 0 _ _� $ I � �1 � 5 Nut coI a _ VIE -------------- --- CONNECTION PLATES FRAME LINE 5 2— — — — — — — — — — — z — I� DID MARK PART EC-5 EC-6 EC-7 1 GCCO ENDWALL FRAMING: FRAME LINE 5 12 U 4 5 z _ z _ — — 0 0 U J 07 IY W r Z W Lu o0 W w Z W LJLJ 0 0 o o � O Z lo 0 0 n u� (n _ 2 u7 � 7 � N N N CD w W CD Li o K6 ci � N N N N N N ENDWALL FRAMING PLAN w co Q~ co ro m m W z Q m w GENERAL NOTES X m w o W 1. STD. ROD/CABLE SIZES PER PART PREFIX ARE: o W v~ J Q' z m CV ROD CABLE ~ _' Z) o RD05- = 5/8" ROD CA02- = 1/4" CABLE RD06- = 3/4" ROD CA03- = 3/8" CABLE RD07- = 7/8" ROD CA04- = 1/2" CABLE RD08- = 1" ROD a RD09- = 1 1/8" ROD RD10- = 1 1/4" ROD ENDWALL SHEETING & TRIM: FRAME LINE 5 2. ROD/CABLE BRACING THAT OCCURS IN FLUSH OR PANELS: 28 Gch CW — FOX � SP INSET GIRT CONDITIONS WILL REQUIRE FIELD SLOTTING OF GIRT WEBS TO ALLOW FOR BRACING. 3. FRAMED OPENINGS WHICH ARE FIELD LOCATED WILL REQUIRE FIELD CUTTING OF GIRTS AND SHEETING. E�oo -- - n 4. THIS DRAWING IS NOT TO SCALE. O W -_=Ii2 lip lipaoagiy m'UEmm `mam'm�m BOLT TABLE FRAME LINE 5 LOCATION QUAN TYPE DIA LENGTH ER-3/ER-4 4 A325 1/2" 2 Columns Raf 4 A325 1 2" 2" TRIM FRAME TABLE LINE 5 OID PART LENGTH DETAIL 1 OCA01 242.000 2 MFB01 121.000 TRIM_? 3 BSC01 122.000 TRIM_722 4 RTA01 121.000 TRIM-2 5 RTA02 242.000 TRIM-2 MEMBER TABLE FRAME LINE 5 MARK PART LENGTH EC-5 W8x10 160.000 EC-6 W8x10 182.688 EC-7 W8x10 205.375 ER-3 W12x14 225.563 ER-4 W12x14 350.938 G-4 08Z060 259.000 G-5 08Z067 259.000 G-6 08Z054 259.000 CB-1 RD05- 329.000 CB-2 RD05- 318.000 FLANGE BRACE TABLE FRAME 5 � ID SIDES MARK CLIP 1 1 FBC30 FBL&N01 Q 1" 12 _JX Panel Start/Finish ENDWALL LINER SHEETING & TRIM: FRAME LINE 1 PANELS: 26 Go. CL — Polar White SP (As Viewed From Inside Of Building) r T ENDWALL LINER SHEETING & TRIM: FRAME PANELS: 26 Ga. CL — Polar White SP (As Viewed From Inside Of Building) LINE 5 IT TRIM FRAME TABLE LINE 1 E 5 A OID PART LENGTH DETAIL 1 HTD194 194.000 TRIM_23 2 HTD194 194.000 TRIM-26 3 FSA04 121.000 TRIM-26 4 HTD096 96.000 TRIM-23 5 HTD096 96.000 TRIM-27 6 HTD096 96.000 TRIM_32 7 HTD121 121.000 TRIM_32 8 HTD194 194.000 TRIM_32 9 MAR02 242.000 TRIM-38 10 HTD096 96.000 TRIM-29 11 HTD121 121.000 TRIM-29 12 CTA02 121.000 TRIM_40 13 HTD121 121.000 TRIM_44 14 HTD096 96.000 TRIM_28 15 HTD121 121.000 TRIM-48 I I I I I 5 5 r r 4 4 4 4 1 1 s a a s TT L------------------ — — — 9 — — —------------------- SIDEWALL LINER SHEETING & TRIM: FRAME LINE E PANELS: 26 Go. CL — Polar White SP (As Viewed From Inside Of Building) SIDEWALL LINER SHEETING & TRIM: FRAME PANELS: 26 Go. CL — Polar White SP (As Viewed From Inside Of Building) IN Panel Start/Finish�� LINE A GENERAL NOTES: 1. FIELD WORK OF THE LINER PANELS AT THE FLANGE BRACE LOCATIONS MAY BE REQUIRED. ERECTOR NOTE: THE ERECTION OF THE LINER PANEL MUST BE COORDINATED PROPERLY WITH THE BRACING AND BRACE STRUTS TO ENSURE PROPER FIT —UP. IT IS THE ERECTOR'S RESPONSIBILITY TO ENSURE THAT THE STRUCTURE IS ADEQUATELY BRACED DURING THE ERECTION PROCESS. TEMPORARY REMOVAL OF BRACING AND BRACE STRUTS IS ACCEPTABLE FOR LINER PANEL ERECTION, PROVIDED ADEQUATE TEMPORARY BRACING IS USED. zr" 1060 FASTENERS 4T 30" O.C. AXIMUM BETWEEN UPPORTS) ;IRT TYPICAL) .INER 'ANEL LASE FASTENER CHART +STITCH FASTENER H1060 STRUCTURAL FASTENER H1040 AT "CLASSIC" WALL *STRUCTURAL FASTENER H1040 AT "REVERSE CLASSIC" H1040 AT "ACCENT" WALL NBS LINER PANEL ERECTION NOTES s (PANELS 36" NET LAY) N U 0- 0 Q OfU J LIJ r W p=p W w Zw w w LO w co Q Q co z W w r- �� w�X m2 w o W 3LWL d r U d w - tam x E� 7S -- - n W -_=n�vE �3aoagiy m'UEmm`mam' RAKE ANGLE (L.L.V.) HOT —ROLLED SIDEWALL MK. MAR01 BUILT-UP (4) 1/2"� x 2" BOLTS - TYP. CLIP MK. GCC03 M M FASTENER MK. H1020 RAFTER A325 BOLTS H0603 / NUTS H0300 CLIP COLUMN SHOP WELDED N N AT EACH SUPPORT PURLIN SHOP WELDED 1n cn CLIP TO COLUMN `' w COLUMN rL OF 4" RAFTER VARIES 4" 6" 3 3 �_ VARIES � N N m N m A 1 1/2" 4 110 � O 00 00 4" VARIES I? 2 " VARIES ERECTOR NOTE: CLIP IS SHOP WELDED L U 0 3 IN PLACE. HOT -ROLLED or BUILT-UP o a 1'-4" 6 1/2" 3 4" a RAFTER ENDWALL COLUMN c1�tL 3" 6 1 2" 6 1 2" 3 4" GIRT ANGLE MK. MAG02 ENDWALL 0 t SECTION A GIRT ANGLE MK. MAG02 W/(3) H1020 m W/(2) H1020 WELDED CLIP 0 ENDWALL RAFTER ENDWALL COLUMN TO RAFTER INSET GIRT AT INTERIOR BAY COLUMN INSET ENDWALL GIRTS AT CORNER 0 USE (4) 1/2" x 1 1/4" A307 o BOLTS H0500 � NUTS H0400 �� 0 HOT -ROLLED or BUILT-UP COLUMN to RAFTER o REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS B3 JO EN c USE (4) 1/2" x 1 1/4" A307 BOLTS H0500 / NUTS H0400 REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS C4 USE (4) 1/2" x 1 1/4" A307 BOLTS HO500 / NUTS H0400 REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS D4 m REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS m ENDWALL ERECTOR NOTE: AT EACH LAPPED GIRT CONNECTION, (1) 1/2" X 1 1/4" THIN LL>3 - a? g RAFTER PURLIN LAP PURLIN LAP HEAD BOLT H0510/NUT H0400 MUST BE USED TO ATTACH THE FIRST GIRT TO THE GIRT CLIP. THE BOLT/NUT ASSEMBLY MUSTS 8$8 zu,•:�: ••at SEE PLAN SEE PLAN BE WRENCH TIGHT PRIOR TO THE LAPPED GIRT BEING INSTALLED. aW �,. 1 1 2" REFERENCE THE STANDARD "LAPPED GIRT DETAIL" FOR MORE •I W $ ® ® ® ® INFORMATION. 3 g W CLIP COLUMN 1E �g�I= ��" SHOP WELDED TO JAMB SHOP PURLIN SHOP WELDED WELDED CLIP GIRT CLEAR OPENING 1 IIIIIIII -W- CLIP CV STEEL LINE SEE BOLT TABLE ON LO ENDWALL FRAMING DRAWING FOR BOLT SIZE AND QTY. 1 0 0 0 DOOR JAMB RAFTER 2 3 4" or[CHANNEL 3 s B FLANGE 01 GIRT LAP GIRT LAP z SEE ELEVATION SEE ELEVATION Z JAMB TO FINISHED FLOOR ENDWALL RAFTER SPLICE PURLIN TO INTERIOR FRAME RAFTER GIRT TO COLUMN o o = w � () W F "ATTACHMENT TO SLAB BY OTHERS** E9 0 BUILT-UP OR HOT -ROLLED RAFTER � v REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS F9 o USE (8) 1/2" x 1 1/4" A307 o BOLTS H0500 / NUTS H0400 m REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS G2 USE (7) 1/2" x 1 1/4" A307 N BOLTS H0500 / NUTS H0400 Qo REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS H2 a m U Z W m w W w BOLTS REQUIRED AS SHOWN, Z W W Of LD W BOLTS REQ'D ONLY AS SHOWN Z (j ROOF LINE PLATE WASHER MK. ESWOI (2) o Ln w a w< z W CD H of a m Lan L0 w w w o X W m a �wJO' mN ofI— U� SECTION "A" ,Sn 3" CAP PLATE/ RAFTER E�oov.�oo� w g w PLATE WASHER MK. ESWO1 (2) EW RAFTER/CAP PLATE SEC. "A" SHOP —WELDED SHELF _ - _ O =22 aav`s EAVE STRUT TO ENDWALL RAFTER HIGH EAVE VERTICAL EAVE STRUT -T TndN�y= 0 USE (4) 1/2" x 2" A325 BOLTS H0603 / NUTS H0300 USE (4) 1/2" x 2" A325 BOLT H0603/NUT H0300 oQ REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS IC7 REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS 117 m m m'UEm BOLTS CAP PLATEI SHOP WELDED SHELF LOW EAVE EAVE STRUT AT BYPASS GIRTS N USE (4) 1/2" x 2" A325 BOLTS H0603 / NUTS H0300 J r� L $� REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS ERECTOR NOTES: -IF THE T-CLIP IS LOCATED IN THE SAME LOCATION AS NESTED GIRT BOLTS, THE NESTED GIRT BOLTS CAN BE REMOVED. -PRE-DRILL HOLES AT NESTED ZEE GIRTS AND DOUBLE CEE GIRTS AS REQUIRED. 4 1/4" <I-- I �-'ZEE GIRT 4 1/4- SHOP- WELDED CLIP JAMB EXTENSION (IF REQ'D) MK. JB- (TEK 3 SHOP SCREWS H10201 I �CLIPDED 4 1/4" <I-- 1—ji �l�CEE GIRT SHOP WELDED CLIP (6) TEK 3 SCREWS H1020 FRAMED OPENING DOOR JAMB TO GIRT REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS L9 alll Tc AT=(1'T1 11All V AC Cwr)wki ROOF LINE VASHER V01 (2) SECTION "A" :AP PLATE/ 4FTER OLD . n HIGH SAVE VERTICAL SAVE STRUT USE (4) 1/2" x 2" A325 BOLTS H0603 / NUTS H0300 REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS J8 8 I 2 1/4' T-( MK. JCE w/ (6) MK. H11 I1TOTel: JAMB TO EAVE STRUT * - DO NOT ALIGN SCREWS WITH HOLES IN CUP USE (2) 1/2" x 1 1/4" A307 BOLTS HO500 / NUTS H0400 L4 REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS IERECTOR NOTE: PRE -DRILL HOLES ® NESTED ZEE GIRTS & DOUBLE CEE GIRTS IF REQUIRED. (6) TEK 3 r GIRT SCREWS H1020 CLIP SHOP WELDED DOOR JAMB DOOR JAMB TO GIRT L8 HOLDBACK CLIP VARIES DIMENSION • • CLEAR OPENING DOOR JAMB • S_84 GIRT (10 Typl 3/4 i TO Ii- OF FIRST SET OF HOLES .3/4" UNPUNCHED SHORT GIRT DETAIL FIELD CUT TO LENGTH AND FASTEN �� WITH (3) H1020 AT EACH END LEFT HAND DET"" ­. RIGHT HAND OF A ��sAS611121 NERS SECTION "A" JAMB TO GIRT CONNECTION L5 CLIP SHOP WELDED TO JAMB GIRT GIRT TO JAMB USE (2) 1/2" x 1 1/4" A307 BOLTS HO500 / NUTS H0400 K3 REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS CUP MK./ JCS— (4) 12-24 x 1 1 L TEK 5 / H1070 I L (2) 1/2"0 x 1 1, BOLTS H05DO/NU (HAND TIGHTEN & BURR THREADS I' 1 L CLEAR OPENING •- JAMB J SECTION A -A 0 0 JAMB TO RAFTER CONNECTION JAMB AT FLUSH OR INSET POST & BEAM ENDW2 L 6 REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS N C O U r. OC) O I= OfU J Lu r Z W W Tb W w Z W LJLI �Z Fn— LLo Ln w c') Q Q co z W w w�X m� w L� o W d Lu U m O _ t w - tam ESoa -- - n - 0 -aEm3oH.— -N,�3�h Nv Q m'UEm CLIP SHOP WELDED 1 ILr 1\1 JI HEADER/SILL TO JAMB USE (2) 1/2" x 1 1/4" A307 BOLTS H0500 / NUTS H0400 M3 REFERENCE ERECTOR NOTE FOR TYPICAL WASHER REQUIREMENTS PURUN 3'-6' 01 W/ H0603 BOLTS H0300 NUTS H0200 WASHERS I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I II II II II II II II II IIII II I I I FBLO1 W H0603 "BASKET -TYPE" INSULATION RAFTER J �� FLANGE BRACE MARK FB ENOE: 2" A325 BOLTS ARE REQ'D LTING FLANGE BRACES. H0603 BOLT TYP FBNOt PRIOR TO INSTALUNG H0300 NUT IDE FABRIC, VAPOR BARRIER H0200 WASHERSR. 0 n? FLANGE BRACE 0 PURLIN & RAFTER a WITH THE USE OF "BASKET -TYPE' INSULATION NOTES: SEE PLANS AND ELEVATIONS FOR FLANGE BRACE PART MARKS LKLU I UK NU I t: UNLESS SPECIFICALLY NOTED OTHERWISE, STANDARD ZEE GIRT ORIENTATION IS TO HAVE THE GIRT TOED DOWN AT THE STEEL LINE AS SHOWN IN THE DETAIL BELOW. UNLESS SPECIFICALLY NOTED OTHERWISE, STANDARD CEE GIRT ORIENTATION IS TO HAVE THE GIRT TOED UP AS SHOWN IN THE DETAIL BELOW. STANDARD CLIP ATTACHMENT IS BELOW THE GIRT, HOWEVER SOME DETAILS REQUIRE THAT THE CLIP BE ABOVE THE GIRT. (REFER TO THE GIRT DETAILS ON THE ERECTION DRAWINGS FOR REQUIREMENTS) BOTH CLIP ATTACHMENTS ARE SHOWN IN THE DETAIL BELOW. COLUMN i -OPTIONAL CLIP CONNECTION ZEE GIRT COLUMN II CEE GIRT w z STANDARD CLIP GIRT CLIP J CONNECTION Lij CLIP II N ZEE GIRT ORIENTATION CEE GIRT ORIENTATION STANDARD GIRT ORIENTATION DETAIL 8 NOTE: BYPASS GIRT CONDITION IS SHOWN FOR REFERENCE 18 ONLY. YOUR PROJECT MAY HAVE FLUSH OR INSET GIRTS. H1020 FASTENER (12" O.C.) SECTION „W N — HEADER WRAP DETAIL 0 VI16 401 PRIOR TO INSTALLING UNDERSIDE VAPOR BARRIER, OR LINER PANEL. H0603 BOLT H0300 NUT H0200 WASHER FLANGE BRAG MK.FB_ (2) H0603 BOLTS 2 H0300 NUTS 200 WASHERS NOTE: X2Y X Y A325 BOLA ARE REWD R BOUND FUWOE BRACES. VOLP) WALL GIRT TYP FLANGE BRACE AT BUILT—UP COLUMN & GIRT SEE PLANS AND ELEVATIONS FOR FLANGE BRACE PART MARKS FIELD CUT AND FLATTEN PANEL RIB IF INTERFERENCE WITH FLANGE BRACE OCCURS. STD. 1/2" A307 BOLTS MK. H0500 (NO WASHERS REQUIRED OUTSIDE FLANGE � I —VIA" / / GIRT LAP BOLTS'XR SHOWN FOR CLAREFERENCE THEECOND LAPPED GIRT DEIRT LAPPED FOR THOSEREQUIREMENTS. OLTED OR THIN HEAD 1/2"ELDED GIRT MK. H0510**UP (NO WASHER REFIRST LAPPED GTD. 1/2" A307 UTS MK. H0400 LAPPED GIRT DETAIL O LAPPED GIRTS 0 INTERIOR BAY COLUMNS U ** THE THIN HEAD 1/2" A307 BOLT MUST BE INSTALLED INTO THE FIRST GIRT AND CUP OF A LAPPED CONDITION. THE BOLT/NUT ASSEMBLY MUST BE WRENCH TIGHT PRIOR TO THE SECOND LAPPED ROD DIAMETER MARK NUMBER HILLSIDE WASHERS FLAT WASHERS A307 A325 NUTS COUPLING NUTS 5/8" 0 RD05-- (2) H0930 (2) H0210 (2) H0310 H0810 3/4" 0 RD06-- (2) H0930 (2) H0220 (2) H0320 H0820 7/8" 0 RD07-- (2) H0930 (2) H0230 (2) H0325 H0830 1" 0 RD08-- (2) H0960 (2) H0240 (2) H0330 H0840 1 1/8" 0 RD09 — (2) H0960 (2) H0250 (2) H0450 H0850 1 1/4" 0 RD10 — (2) H0960 (2) H0260 (2) H0340 H0860 WEB OF -_-44 COLUMN OR RAFTER COUPLING NUT (QUANTITY VARIES) SEE PLANS AND ELEVATIONS FOR BRACING MARK NUMBERS ROD ASSEMBLY MK. RD__ HILLSIDE WASHER, FLAT WASHER, AND \NUT ROD BRACE ° WEB TO WEB Q3 FABRIC, VAPOR BARRIER, OR LINER PANEL. NOTE: 1 2"f X 2" A325 BOL1S ARE REQ'D FLANGE BRACE MARK FI3 . IND FIANOE BRACES. CF COLUMN--,7 rFBL01 US) I FBN01 W (2) H0603 BON (2) H0300 NUTS 200 WASHERS 'ED FROM BOTTOM 2'-5 1/4" or 3'-5 1/4" WALL GIRT WP FLANGE BRACE 0 COLD —FORMED COLUMN & GIRT SEE PLANS AND ELEVATIONS FOR FLANGE BRACE PART MARKS FIELD CUT AND FLATTEN PANEL RIB IF INTERFERENCE WITH FLANGE BRACE CUP OCCURS. FBC__ VINDICATES LENGTH OF FLANGE BRACE IN INCHES BLANK LENGIH---, FBH- COUNTER (1-999) SPECIAL LENGTH FLANGE BRACE FBE__ COUNTER (01-07) FBJ- COUNTER (1-999) COPED FLANGE BRACE SPECIAL LENGTH COPED FLANGE BRACE FBF- COUNTER (1-999) FBK__ 3" X 3" 1/4" BRACE ANGLE VINDICATES LENGTH OF FLANGE BRACE IN INCHES BLANK LENGM" BLANK LENGTH FLANGE BRACE MARK NUMBERS NAG0003 1 1/2" MIN. 2 1 /2" (MAX. WIDTH) 1 1/2" MIN. 1 -0" (MAX. LENGTH) GIRT SECTION 'A' e1,' , . ' GIRT (SHOWN) JAMB (SIMILAR) ROD OR CABLE BRACING, SEE STRUCTURAL ELEVATIONS FOR SIZE AND LOCATIONS GUIDELINES FOR FIELD SLOTTING SECONDARY e WEBS AT INSET/FLUSH CONDITIONS FIELD SLOT N U D- Oo w0 z 5 W 07 X z LU LU 0� ~ Z 00 w M UJ Z� rn U w FLU a z 0 H w J r F LU L w ___1 LU LU � 0 C/) Q Lu L0 Q co w� �LU Z� Z o � o t w =t a E§zii --8. - to CD -Et= O -aEm3o- v3�h - -a Nv Q m'UEm TYPICAL FIELD WELD COLLATERAL DEAD LOADS, UNLESS OTHERWISE NOTED, ARE ASSUMED TO BE REQUIREMENTS ERECTOR NOTE: UNIFORMLY D. WHENSREPENDED KLER ROOFMM, LIGHTING, UNLESS NOTED OTHERWISE ON DRAWINGS HVAC EQUIPM N , CEILINGS, ETC. SUSPENDEDNFROM EMBERS, CONSULT ENGINEER OF RECORD IF THESE CONCENTRATED LOADS EXCEED 500 IMPORTANT ERECTOR NOTE: N N POUNDS (USING THE WEB MOUNT DETAIL) OR 200 POUNDS (USING THE FLANGE MOUNT DETAIL), OR IF INDIVIDUAL MEMBERS ARE LOADED SIGNIFICANTLY MORE ALL FIELD WELDING MUST BE PERFORMED BY AWS/CWB CERTIFIED WELDERS THAN OTHERS. WHO RE QUALIFIED FOR THE WELDING PROCESSES AND POSITIONS INDICATED. PLEASE REFER TO THE SHEETING ERECTION MANUALS F 0 R m m ALL WORK MUST BE COMPLETED AND INSPECTED IN ACCORDANCE WITH THE PURLIN FLANGE APPLICABLE AWS/CWB SPECIFICATIONS. PURLIN STIFFENING UP FURTHER ASSEMBLY INSTRUCTIONS U U m m WELD ELECTRODES USED FOR THE SMAW (OR STICK) WELD PROCESS PURLIN WEB MUST BE 70 KSI/483 MPa MATERIAL AND LOW HYDROGEN CONTENT. GENERAL RESTRICTION: GALVANIZED STEEL FIELD WELDING UNDER NO CIRCUMSTANCES CAN THE PURLIN STIFFENING LIP ONLINE VIDEO AND MANURES ARE ALSO AVA I LAB E E q RECOMMENDATIONS BE FIELD MODIFIED FROM THE FACTORY SUPPLIED CONDITION. ALSO DO NOT HANG ANYTHING FROM PURLIN STIFFENING LIP. . w d PREPARATION OF WELD AREA PRIOR TO STARTING THE SHEETING PLEASE VISIT: AWS D-19.0, WELDING ZINC COATED STEEL, CALLS FOR WELDS TO BE m MADE ON STEEL THAT IS FREE OF ZINC IN THE AREA TO BE WELDED. FOR GALVANIZED STRUCTURAL COMPONENTS, THE ZINC COATING SHOULD BE OPTIONS FOR SUPPORT ATTACHMENTS OPTION A OPTION B https://www.nucorbuildingsystems.com/resources/manuals/ t REMOVED AT LEAST ONE TO FOUR INCHES (2.5-10 cm) FROM EITHER SIDE (200 LBS MAX) (500 LBS MAXI M OF THE INTENDED WELD ZONE AND ON BOTH SIDES OF THE WORKPIECE. DRILL SUPPORT SUPPORT ANGLE OR SOME GRINDING BACK THE ZINC COATING IS THE PREFERRED AND MOST COMMON THROUGH THE OTHER TYPE OF METHOD; BURNING THE ZINC AWAY OR PUSHING BACK THE MOLTEN ZINC BOTTOM FLANGE OF BRACKET. (NOT BY NBS) >S� FROM THE WELD AREA ARE ALSO EFFECTIVE. THE PURUN. SUPPORT THROUGH PURLIN WEB. a 0 93N , TOUCH—UP OF WELD AREA 1/2"0 MAXIMUM BOLT INSTALLATION INSTRUCTIONS SEAMING MANUALS : i bilef 8 Gh WELDING ON GALVANIZED SURFACES DESTROYS THE ZINC COATING ON AND ROUND THE WELD AREA. RESTORATION OF THE AREA WILL BE (NOT BY MBS) ANGLE SUPPORT a 5^ PERFORMED IN ACCORDANCE WITH ASTM A 780, STANDARD PRACTICE FOR REPAIR OF DAMAGED AND UNCOATED AREAS OF HOT —DIP GALVANIZED (NOT BY MBS) CFR Standing Seam Installation CFR Standing Seam r3LL>� < g g COATINGS, WHICH SPECIFIES THE USE OF PAINTS CONTAINING ZINC DUST, ZINC —BASED SOLDERS OR SPRAYED ZINC. ALL TOUCHUP AND REPAIR 1" MAXIMUM FROM MAXIMUM FROM CFR Installation Videos SR2 Insulated Standing Seam •" W§W METHODS ARE CAPABLE OF BUILDING A PROTECTIVE LAYER TO THE WEB TO CENTERLINE OF WEB TO CENTERLINE OF SUPPORT SUPPORT g r $ W THICKNESS REQUIRED BY ASTM A 780. Video de Instalacion de cubierta tipo VR16 II Vertical Rib ,W SAFETY &HEALTH = �� � g � � � WHEN WELDING DIRECTLY ON GALVANIZED STEEL IS UNAVOIDABLE, OSHA CIgSSIC Roof Installation PERMISSIBLE EXPOSURE LIMITS (PELS) MAY BE EXCEEDED AND EVERY OPTION C: PRECAUTION, INCLUDING HIGH —VELOCITY CIRCULATING FANS WITH FILTERS, 200 LBS MAX ±1" AIR RESPIRATORS AND FUME —EXTRACTION SYSTEMS SUGGESTED BY AWS, IF PURUN FLANGE VR16 II Vertical Rib Installation SHOULD BE EMPLOYED. FUMES FROM WELDING GALVANIZED STEEL CAN SUPPORT CLAMPS 'X" = TOTAL PROJECTED CONTAIN ZINC, IRON, AND LEAD. FUME COMPOSITION TYPICALLY DEPENDS ARE USED. DISTANCE FROM THE CENTERUNE OF THE SPECS & OTHER GUIDES HR3 Insulated Roof Installation ON THE COMPOSITION OF THE MATERIALS USED, AS WELL AS THE HEAT PURUN WEB TO THE END APPLIED BY THE PARTICULAR WELDING PROCESS. IN ANY EVENT, GOOD OF THE END OF STIFFENER VENTILATION MINIMIZES THE AMOUNT OF EXPOSURE TO FUMES. LIP. (= 3 5/8" +/— 1/16") SR2 Insulated Standing Seam Master Spec 13 34 19 PRIOR TO WELDING ON ANY METAL, CONSULT ANSI/ASC Z-49.1, CLAMP 1" MAXIMUM NOTE: SAFETY IN WELDING, CUTTING AND ALLIED PROCESSES, WHICH CONTAINS INFORMATION ON THE PROTECTION OF PERSONNEL AND THE GENERAL (NOT BY NBS) THE CENTERUNE OF THE SUPPORT MUST BE WITHIN 1" FROM Insulated Wall Sheeting NBS Specification Guide CENTERUNE OF THE PURLIN WEB. U AREA, VENTILATION AND FIRE PREVENTION. z INFORMATION COURTESY OF AMERICAN GALVANIZERS ASSOCIATION CENTERUNE OF SUPPORT CENTERUNE OF PURLIN PURLIN SUPPORT METHODS Single Curb Installation Preventative Maintenance Manual Double Curb Installation o o = z _o ~ U TYPICAL FIELD WELD REQUIREMENTS o NM0040 LU BOLT HEAD SLOT SLOT TO SLOT CONNECTIONS WASHER BOLT/NUT ASSEMBLY WASHERS ARE REQUIRED ON REQUIRED AT LAPPED BOTH SIDES OF MATERIAL IF Z w UJ � w W 0 ZEE MEMBERS. (NO NUTWASH!!! SLOTS ARE USED ON BOTH WASHERS REQUIRED NUT SLOT SIDES NOTE LAPPED ZEE ) m Z o LO — U Q � MEMBEREXCEPTION). BOLT HEAD SLOT SLOT TO HOLE CONNECTIONS y "A" w Z LU w 2 m w WASHER ONE WASHER REQUIRED ON SECTION SLOTTED SIDE ONLY. C\I o NUT _ HOLE LAPPED ZEE BOLT HEAD HOLE HOLE TO HOLE CONNECTIONS MEMBERS, NO WASHERS ARE REQUIRED GURTS OR WHEN SLOTS ARE NOT USED. LAPPED NESTED REGION NUT-74iHOLE •Q WASHER PART NUMBERS W H0200 — 1/2:: FLAT WASHER H0240 — 1" FLAT WASHER N H0210 — 5/8„ FLAT WASHER H0250 — 1 1/8" FLAT WASHER d w H0220 — 3/4 FLAT WASHER H0260 — 1 1/4 FLAT WASHER H0230 — 7/8" FLAT WASHER tmm= Eaoad4;„ao t� W y=did_= �m a a�INz��o@Qo ono O TYPICAL WASHER REQUIREMENTS ERECTOR NOTE NO WASHERS REQUIRED AT BOLTS USED IN mnEF�� dnE-q � Q (UNLESS NOTED OTHERWISE ON DRAWINGS) THE LAPPED REGIONS OF ZEE MEMBERS. IKE E3a NAA0030 SECTION "B" m'UEm 0 a 0 INSULATION (BY OTHERS) GIRT AT 7'-6" A.F.F. H1040 EA. END — EXTERIOR WALL PANEL ITT — PANEL SIC WALL" SHOWN) DOOR TRIM ELEVATION WALKDOOR FLOOR ERECTION DETAILS USE ONLY WHERE STANDARD NUCOR DOORS ARE REQUIRED. SEE COVERSHEET (SHEET Cl) FOR STANDARD DOOR REQUIREMENTS. LINER PANEL (IF REQ'D.) --\ LINER HEAD COVER AT 8" GIRTS 3070 DOOR MK. HTB01 6070 DOOR MK. HTB02 AT 10" GIRTS 3070 DOOR MK. HTC01 6070 DOOR MK. HTCO2 AT 12" GIRTS 3070 DOOR MK. HTC11 6070 DOOR MK. HTC12 (FIELD CUT AS REQUIRED) LINER CAP TRIM MK HTD121 BUILDING GIRT AT 7'-6" ELEV.— DOOR HEADER FACTORY INSTALLED DOOR JAMB 00'0" _jI � FACTORY INSTALLED ZDOOR� SUBJAMB, FACTORY INSTALLED ON DOOR (3) SELF -DRILLING SCREWS (PROVIDED IN HARDWARE KIT) CLIP - FACTORY ATTACHED TO JAMB (ADJUST AS REQ'D) DOOR FRAME INSTALLATION AT TOP STAND FRAME & ADJUST CLIP AT JAMB AS REQUIRED. �iULWPIAtj to SCREWS EWS(PROVIDED IN HARDWARE KIT) CLIP - FACTORY ATTACHED TO JAMB (ADJUST AS REQ'D) (2) 1 /2" 0 EXPANSION BOLTS (PROVIDED IN HARDWARE KIT) DOOR FRAME INSTALLATION AT BASE STAND FRAME & ADJUST CLIP AT JAMB AS REQUIRED. ATTACH CLIP TO GIRT WITH (4) SELF -DRILLING SCREWS. LINER (IF REQ'D.) ELEV.= (REQ'D. AT LINER ONLY) CAP TRIM MK. HTD121 AT "ACCENT" AND "CLASSIC" SUBJAMB HEAD TRIM PANEL. JTDO87 AT MK. HTA044 AT 3070 DOOR "REVERSE CLASSIC" PANEL. MK. HTA080 AT 6070 DOOR (AT LINER ONLY) DOOR JAMB JAMB COVER MK. JTB01 AT 8" GIRTS DOOR 1 AT 10" GRTS MK. JTCJTC�2 AT 12" GIRTS (REQ'D. AT LINER ONLY) (FIELD CUT AS REQUIRED) C 7(5) H1040 EQUALLY SPACED HEAD TRIM DETAIL - SECTION B GIRT (BELOW 7'-6" ELEV.) SUBJAMB DOOR JAMB FACTORY SUPPLIED CLIP WITH (4) SELF -DRILLING SCREWS (PROVIDED IN HARDWARE KIT) DOOR GIRT TO SUBJAMB DETAIL USE (2) 1/2" X 1 1/4" A307 BOLTS H0500/NUTS H0400 FIELD CUT GIRT TO LENGTH AS REQUIRED. FIELD WORK HOLES IN GIRT TO ACCEPT CLIP AS REQUIRED. REFERENCE STANDARD WASHER DETAIL FOR TYPICAL WASHER REQUIREMENTS 1 SULATION BY OTHERS) CAP TRIM MK. JTDO87 AT "REVERSE CLASSIC" PANEL (REQ'D. AT LINER ONLY) CAP TRIM MK. HTD121 AT AT ACCENT AND "CLASSIC" PANEL (REQ'D. AT LINER ONLY) JAMB COVER MK. JTBO1 AT 8" GIRTS MK. JTC01 AT 10" GIRTS MK. JTC12 AT 12" GIRTS (REQ'D. AT LINER ONLY) (FIELD CUT AS REQ'D) DOOR JAMB fV N 1 fV 7" N N N N 7" 1 N lV N fV 7" N HIGH EAVE, RIDGE, & END LAP 12" 12" 12" N N N "1 9 1 2" c4i 9 1 2" -1 9 1 2" INTERMEDIATE PURLINS N N N M N N M N N N M NI N N M N N N N M N N M N I SEE THE CLASSIC ROOF SIDE LAP FASTENER SPACING DETAIL FOR SIDE LAP FASTENER SPACING END LAP IF REQUIRED STRUCTURAL FASTENER MK. H1030� LOW EAVE END OF PANEL RIDGE OR HGH EAVE PURLIN — PURLIN END LAP PURLIN (IF END LAP IS REQUIRED) \ EAVE MEMBER (VARIES), EAVE INTERMEDIATE LOW EAVE STRUT SHOWN FOR REFERENCE PURLIN CLASSIC ROOF STRUCTURAL FASTENER SPACING (STANDARDZ 6. SEE DETAILS BELOW LEFT FOR SIDE LAP FASTENER g" 6" 0•C SPACING AT THE REMAINDER OF THE PANEL RUN g" MAX 6" 6" O.C. 6" SIDE LAP FASTENERS MK. H1050 AT EACH SUPPORT AND 6" ON CENTER B EEN SUPPORTS AT THE FIRST TWO LOW EAVE PURLIN SPANS ROOF PANEL EAVE MEMBER URLI TYPICAL SIDE LAP VARIES, EAVE HOW SEE THE CLASSIC ROOF STRUCTURAL STRUT SHOW FASTENER SPACING DETAIL FOR STRUCTURAL FASTENER SPACING FIRST TWO LOW EAVE SPANS (EACH SUPPORT AND 6" ON CENTER BETWEEN SUPPORTS) EQUAL EQUAL EQUAL ROOF PANEL URLI SPANS > OR = TO 5'-0" (EACH SUPPORT AND 1/3 POINTS BETWEEN SUPPORTS) SECOND PURLIN UPSLOPE FROM EAVE * EQUAL* nrtai rvrtLan EQUAL UPSLOPE FROM EAVE EAVE MEMBER (VARIES), EAVE STRUT SHOWN FOR REFERENCE ROOF PANEL 3/32" x 1/2" TAPE URLI MASTIC MK. H3010 SPANS LESS THAN 5'-0" NON-UL 901 EACH SUPPORT AND MIDPOINT BETWEEN SUPPORTS. UL 90 EACH SUPPORT AND SPACED EQUALLY BETWEEN SIDE LAP MASTIC DETAIL SUPPORTS. NOT TO EXCEED 20" (1'-8"). (AT FULL LENGTH OF ALL SIDE LAPS) CLASSIC ROOF SIDE LAP FASTENER SPACING (STANDARD) —DOOR STANDARD FASTENER SCHEDULE JAMB TRIM MK. JTA087 H1000 SELF -TAPPING SCREW SELF -DRILLING SCREW H1070 SELF-DRIWI GOOF SCR H 1042 12-14 x 7" x 8 12-24 1 1 AT "ACCENT AND ( H "CLASSIC" WALL PANEL 7-14 x 1 1/4" TCP3 W/O WASHER w/ WITH WASHER 5/ LONG LIFE FASTENER 1/2• EXTERIOR I JAMB TRIM MK. ITDO87 WALL PANEL AT "REVERSE CLASSIC" WALL PANEL JAMB TRIM DETAIL - SECTION C 3/8" HEAD 1/4-14 x 1 1/4" W/0 WA 56" 3/16/1" THK DRILLING CAP 11030 SELF -DRILLING S, 12-14 x 1 fm TCP2 WITH WA LONG LIFE FAST 5/16" 11035 SELF -DRILLING S, 12-14 x 1 TCP2 WITH WA LONG LIFE FAST H1040 SELF -DRILLING I 12-14 x 1 bill"" TCP2 W/0 W I-II���� 5/16"0 H1041 SELF -DRILLING 12-14 x 1 TCP2 FLA WALKDOOR 5�18 5/16" HEAD H1045 SELF -DRILLING SCREW 12-14 x 2" A=M�16' TCP3 W/O WASHER HEAD H1047 SELF -DRILLING SCREW 12-14 x 2" TCP3 FLAT TOP dfit WITH WASHER 5/16"0 HEAD 1/4-14 x WT1 qF1LONG LIFE 1060 SELF -DRILLING S 1/4-14 x 7/8" W/0 W 5/16" 1061. SELF -DRILLING E 1/4-14 x TCP7 FLA WITH W 5/16"0 1/8" x STAINLESS BLIND POP H 1 1 10 3/8.0 STAINLE GROMMET FASTEN H1220 SELF -DRILLING SCRI 12-14 x 1" TO W/O WASH PHIWPS HE PRE -DRILL DIAMETER 3/16"0 FOR: H1020, H1070 5/32"0 FOR: H1030, H1035, H1040, H1041, H1042, H1045, H1047, H1220 1/8"0 FOR: H1050, H1060, H1061 N 0 U U 1 Z Z 0-O D I.- c) N = 0 07 U W zLI w LLLI m w Z W LL] L w � Lo w M Q Q D co Z w� w� �e w C w�X o m� LLI w m L� d r U Z) 0 - t6m x gym_ =Eta 3-A -aE- Lo m'UEm THIS BUILDING IS DESIGNED, MANUFACTURED, AND DELIVERED IN ACCORDANCE WITH MOST RECENT ADDITION OF THE M.B.M.A. METAL BUILDING SYSTEMS MANUAL. CONSULT THE INFORMATION IN THE "COMMON INDUSTRY PRACTICES" SECTION. CHECK SHIPMENT AGAINST DELIVERY TICKETS DURING UNLOADING. NOTE ANY DAMAGE OR DISCREPANCIES ON THE DELIVERY TICKETS BEFORE SIGNING AS RECEIVER. METAL BUILDING SUPPLIER IS NOT RESPONSIBLE FOR CARRIER DAMAGE OR DISCREPANCIES NOT NOTED ON THE DELIVERY TICKETS. THE CUSTOMER ASSUMES FULL RESPONSIBILITY FOR THE CONDITION OF THIS MATERIAL AFTER DE VERY BY THE TRUCKING COMPANY. METAL BUILDING SUPPUER IS NOT RESPONSIBLE FOR ITEMS ACCEPTED IN QUESTIONABLE CONDITION. UPON ACCEPTANCE OF SHIPMENT(S), THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER STORAGE AND HANDLING OF MATERIALS AS DESCRIBED IN METAL BUILDING SUPPLIER'S DOCUMENTATION. METAL BUILDING SUPPUER IS NOT RESPONSIBLE FOR INJURY, DAMAGE, OR LOSS AS A RESULT OF IMPROPER STORAGE AND/OR HANDLING. ALL CLAIMS MUST BE FILED WITH METAL BUILDING SUPPUEWS QUALITY SERVICES REPRESENTATIVE PRIOR TO ANY FIELD MODIFICATIONS OR PURCHASES THAT MAY RESULT IN A CHARGE TO METAL BUILDING SUPPLIER. WALL PANELS ARE ROLLED AND BANDED, WITH A COVER PANEL PLACED TOP AND BOTTOM. PANEL BUNDLE WEIGHT CAN BE FOUND ON I.D. TAG AT LOW END OF EACH BUNDLE. MAXIMUM WEIGHT IS 4,300 POUNDS. BUNDLES UP TO 25 FEET CAN BE HANDLED USING A FORKLIFT. FORKS MUST BE SPACED A MINIMUM OF FIVE FEET APART. BUNDLES OVER 25 FEET SHOULD BE HANDLED WITH A CRANE USING A SPREADER BAR AND NYLON SONGS. LIFTING SHOULD OCCUR AT CENTER OF GRAVITY. LOCATE SLINGS AT 1/4 OF THE LENGTH OF THE PANEL FROM EACH END OF THE BUNDLE. TRIM CRATES/BOXES ARE TO BE HANDLED THE SAME AS PANEL BUNDLES. PANEL AND TRIM BUNDLES / CRATES SHOULD BE BLOCKED 12 INCHES ABOVE GRADE AND ELEVATE ONE END TO ALLOW MOISTURE TO DRAIN. IF THE PANELS ARE WET, THE BUNDLES SHOULD BE OPENED AND THEN THE PANELS SHOULD BE DRIED AND RE -STACKED TO PREVENT DAMAGE. LOOSELY COVER WITH WATERPROOF TARP TO ALLOW PROPER AIR CIRCULATION. INSPECT DAILY AND DRY IF NECESSARY. ACCESSORIES MUST BE KEPT DRY AND FREE OF CONTAMINATION. STORE INDOORS IF POSSIBLE IMPORTANT NOTE: THE FINISH ON THESE PANELS MAY NOT PERFORM AS INTENDED IF NOT ERECTED WITHIN DAYS FROM RECEIPT AT THE JOB SITE THE FINISH IS ALSO SUBJECT TO SEVERE DAMAGE IF MOISTURE, DEBRIS, OR DUST IS ALLOWED TO GET BETWEEN THE PANELS, THEREFORE, PANELS MUST BE STORM UNDER COVER WITH ONE END ELEVATED TO ALLOW FOR DRAINAGE AND PROTECTION AGAINST MOISTURE, DUST, OR DEBRIS UNTIL ERECTED. THE MANUFACTURER WILL NOT ACCEPT CLAIMS FOR NON -PERFORMING PANELS IF NOT PROPERLY STORED AT THE JOBSTTE. THE CUSTOMER ASSUMES FULL RESPONSIBILITY FOR THE CONDITION OF THIS MATERIAL AFTER DELIVERY BY THE TRUCKING COMPANY. BUILDING & PANEL PREPARATION sQUARE SQUARE STEP 1: PLUMB AND SQUARE THE FIRST STEP IN THE SUCCESSFUL INSTALLATION OF WALL PANELS IS TO HAVE THE PRIMARY FRAMING PLUMB AND SQUARE. FOR BEST RESULTS, IT IS RECOMMENDED THAT A TRANSIT BE USED WHEN ERECTING THE STRUCTURAL STEEL MAKE SURE THAT THE FOUNDATION AND BUILDING STRUCTURE IS SQUARE, LEVEL. AND CORRECT TO THE OUT -TO -OUT STEEL LINE DIMENSIONS. SEE FIGURE A' FIGURE "A" STEP 2: GIRT BLOCKING BLOCK GIRTS TO •LEVEL• POSITION BEFORE STARTING THE WALL SHEEITNG OR INSULATION. CHECK TO BE SURE THAT EAVE MEMBER THE EAVE STRUT AND GIRTS ARE STRAIGHT AND PLUMB. TO ALIGN THE GIRTS, CUT TEMPORARY WOOD BLOCKING TO THE FRAME PROPER LENGTH AND INSTALL BETWEEN THE LINES OF GIRTS. THIS BLACKING CAN BE MOVED FROM BAY TO BAY WHICH WILL REDUCE THE NUMBER OF PIECES REQUIRED. NORMALLY, ONE LINE OF BLOCKING PER BAY WILL BE GIRT SUFFICIENT BUT WIDER BAYS MAY REWIRE MORE. IT IS FOUNDATION RECOMMENDED TO BLACK AT LEAST TWO HAYS AND LEAP FROG THE BLOCKING AS A BAY IS SHEETED. BLOCKING BLOCKING (NOT BY SHOULD NOT BE REMOVED UNTIL THE FULL BAY HAS BEEN METAL BUILDING SHEETED. - SUPPUER) SEE FIGURE "S' FIGURE "B" STEP 3: PRE -DRILL PANEL LAP STACK PANELS WITH ENDS FLUSH ON A LEVEL PLACE ON THE DRILL GROUND IN PILES NOT EXCEEDING 10 PANELS. THEN PLACE TOP SMALL WOODEN BLOCKS UNDER SIDE LAPPING EDGE OF STACK OF PANELS TO HOLD THEM AT CORRECT HEIGHT AND POSITION WHILE DRILLING FASTENER HOLES. HOLD PANELS TIGHTLY TOGETHER AT EACH END WITH CLAMPING PUARS. CAREFULLY MARK POSITIONS FOR SIDELAP FASTENERS ON TOP OF HIGH RIB. FASTENERS SHOULD BE LOCATED 'ON CENTER' OF HIGH RIB. DRILL HOLES FOR 'STITCH' FASTENERM WOOD BLOCK (USE #1,-7/32" - 15/64' DRILL -BIT) ON TOP SHEET OF 3'-0' PANEL COVERAGE SIDELAP. BE SURE PANELS ARE WELL NESTED BEFORE DRILLING. SEE FIGURE "c" FIGURE "C" BR LAP PRE-DRILIFD TOP PANEL H1060 STITCH FASTENER H1040 STRUCTURAL FASTENER �I�IIAI�11 n R;1 H7060 AT EACH END AND AT 30" D.C. MAX BETWEEN SUPPORTS BASE MEMBER FIGURE "E" I WALL PANEL ERECTION DETAIL IL WHEN FIELD CUTTING OR MITERING WALL PANELS, NON-ABRASIVE CUTTING TOOLS SUCH AS NIBBLERS OR STEP 1: INSTALL FlRSf PANEL TIN -SNIPS SHALL BE USED. ABRASIVE CUTTING TOOLS SUCH AS MECHANICAL GRINDERS OR POWER SAWS INSTALL THE FIRST WALL PANEL AT THE BUILDING CORNER AND ALIGN THE PANEL RIB WITH THE STEEL LINE AS SHOWN CAN DAMAGE THE MATERIAL FINISH AND CREATE EXCESS METAL SHAVINGS THAT CAN CORRODE THE PANELS. IN THE CORNER DETAILS USING THE STARE/FINISH DIMENSION SHOWN ON THE PLAN. IT IS EXTREMELY IMPORTANT THE USE OF NON -APPROVED CUTTING DEVICES MAY VOID THE FACTORY WARRANTY. THAT THE FIRST WALL PANEL IS INSTALLED PLUMB AND SQUARE. USE A LEVEL OR A TRANSIT TO AID IN THIS PROCESS. ANY METAL SHAVINGS THAT ARE CREATED NEED TO BE CLEANED FROM THE PANEL TO PREVENT SCRATCHING PLACE A 1/8' SHIM ON THE BASE TRIM UNDER THE PANEL TO HOLD THE PANEL OFF THE BASE TRIM. ENSURE THAT THE AND/OR CORROSION. THE MANUFACTURER WILL NOT ACCEPT CLAIMS FOR DAMAGE/DETERIOPATION DUE TO USE WEIGHT OF THE PANEL DOES NOT FORCE BASE TRIM TO EXCESSIVELY BEND DOWN. BASE TRIM SHOULD HAVE A SLIGHT OF UNAPPROVED TOOLS. SLOPE TO ALLOW WATER TO RUN OUT AND NOT SIT ON BASE TRIM. SEE FIGURE 'D" - TO RIGHT FASTENER INSTALLATION 4 AMP OR HIGHER RATED TOOLS (DO NOT USE IMPACTING TOOLS) 2000 - 2500 RPM SCREW GUN WITH TORQUE ADJUSTABLE CLUTCH MANUAL OR ELECTRIC RIVET TOOL DO NOT USE IMPACTING TOOLS TO ASSURE PROPER VOLTAGE TO THE TOOL, EXTENSION CORDS SHOULD BE CHECKED FOR PROPER WIRE SIZE/CORD LENGTH. 16 GAGE WIRE, MAXIMUM CORD LENGTH 100' 14 GAGE WIRE, MAXIMUM CORD LENGTH 200' 12 GAGE WIRE, MAXIMUM CORD LENGTH = 300' DRIVING TIPS: SET THE NUF DRIVER AS DESCRIBED BELOW PRIOR TO INSTALLING FASTENERS TO PREVENT FASTENER WOBBLE. COMPRESS THE INSULATION AT FASTENER LOCATION WITH ONE HAND WHILE DRIVING THE FASTENER WITH THE OTHER. THIS WILL HELP KEEP THE PANEL FLAT AND PREVENT THE FASTENER FROM ?WALKING?. DRIVE FASTENERS PERPENDICULAR TO PANEL SURFACE EXCESSIVE PRESSURE CAN CAUSE DRILL POINT FAILURE. LEI THE FASTENER DO THE WORK. DO NOT OVER TIGHTEN FASTENERS AS THIS WILL LEAD TO PANEL DIMPLING AND DISTORTION. wm 1. PUT THE TOP OF THE FASTENER INTO THE NUT DRIVER. M1 FOR PAINTED FASTENERS, PLACE A SINGLE OR DOUBLED LAYER OF PLASTIC BETWEEN THE FASTENER HEAD AND THE NUT DRIVER. 3. THE BASE OF THE NUT DRIVER SHOULD NOW BE CONTACTING THE TOP OF THE HEAD OF THE FASTENER WITH NO GAPS. 2. PUCE THE POINT OF THE FASTENER ONTO A HARD SURFACE AND FIRMLY HIT THE TOP OF THE NUT DRIVER 2-3 TIMES. 4. BAD SET VS. GOOD SET. NO GAP WHEN INSTALLING THE PANEL, APPLY PRESSURE EVENLY TO AVOID DISTORTING THE PANEL AND CAUSING OIL CANNING. SEE FIGURE 'E' - ABOVE RECOMMENDED PANEL FASTENING SEQUENCE IS SHOWN TO THE RIGHT. THIS PATTERN AIDS IN PLUMBING AS WELL AS MAINTAINING PANEL COVERAGE / MODULARTY. SOME APPUCATIONS MAY REQUIRE MODIFIED SEQUENCE AND WILL BE BEST DETERMINED IN THE FIELD. F THE INSTALL THE SECOND PANEL BY LAYING THE LAP EDGE OVER THE BEARING RIB OF THE FIRST PANEL SEE BELOW FOR PROPER ALIGNMENT AT SIDELAP. CHECK PANEL PLUMBNESS AND FASTEN PANEL IN THE SAME SEQUENCE STARTING WITH THE STRUCTURAL FASTENERS ALONG THE LAP TO ENSURE A TIGHT SIDELAP. CONTINUE FOR THE REMAINDER OF THE WALL, CUTTING PANELS AROUND FRAMED OPENINGS AS REQUIRED. (TRIM SHOULD BE INSTALLED AROUND OPENINGS PRIOR TO INSTALLING PANEL) RECOMMENDED TPS� WALL PANELS CAN BE INSTALLED LEFT TO RIGHT OR RIGHT TO LEFT. IT IS RECOMMENDED TO INSTALL SHEETS STARTING OPPOSITE THE PREVAILING VIEW / WIND SO THAT THE SIDELAP SEAM IS AWAY AND LESS NOTICEABLE `YN�HG AA� L' Y BASE TRIM (TRIM PROFILE VARIES PER PROJECT) ATTACHMENT TO FOUNDATION IS NOT BY METAL BUILDING SUPPLIER SIDE LAP WITH STITCH FASTENERS (SEE WALL PANEL ERECTION DETAIL FOR MARK NUMBER AND SPACING) SAVE FLASH NOT SHOWN FOR CLARITY. (SEE ERECTION DRAWING LAW EAVE DETAIL FOR FASTENER REQUIREMENTS AND PART NUMBERS) STRUT N 0 U n §a z"� p -GIRT (SPACING] .. VARIES PER PROJECT)it s Zs �{Sg GIRT BLOCKING AS 4 ffi DESCRIBED IN BUILDING SSS g AND PANEL PREPARATION STEP 2 (NOT BY METAL BUILDING SUPPLIER) CORRECT OVERBENT UNDERBENT SHOWS GAP O HIGH RIBS HOLDS WATER NOTE: BASE TRIM PROFILES ARE MANUFACTURED WITH A 5' SLOPE TO PROMOTE WATER SHED. ENSURE SLOPE IS PRESENT TO PREVENT HOLDING WATER. DO NOT ALLOW WEIGHT OF PANEL TO OVERSEND TRIMCREATING LARGER GAP AT RIB OF PANEL FIGURE "D" PANEL ORIENTATION AND ALIGNMENT BASE TRIM LAP SEALANT NOTE THE ORIENTATION OF THE PROFILE AND BEARING LEG FOR THE LEADING EDGE OF THE PANEL PANELS AT BASE TRIM LAPS, APPLY A BEAD OF POLYURETHANE TUBE CAULK (H3152) TO ALL ADJOINING SHOULD BE INSTALLED AS SHOWN BELOW TO HELP MAINTAIN PANEL MODULARITY / COVERAGE FOR THE SURFACES AND LAP 1". SEE BASE TRIM DETAIL FOR THE SPECIFIC TRIM FOR YOUR PROJECT. LENGTH OF THE WALL. PANEL ERECTION ABC - LONGSPAN III LAP LEG CBC - R-PANEL KBS - KIRBYRIB II TUBS -CLASSIC WALL STEEL LINE BEARING LEG MAY VARY TUCK PANEL TIGHT TO THIS CORNER ABC - ARCHITECTURAL V LAP LEG CBC - A -PANEL KBS - KIRBYWALL TUBS -ACCENT PANEL STEEL LINE BEARING LEG MAY VARY TUCK PANEL TIGHT TO THIS CORNER ABC - ARCHITECTURAL III LAP LEG CDC - REVERSE R-PANEL KBS - KIROY REVERSED ROLL NBS - REVERSE CLASSIC WALL STEEL UNE BEARING LEG IF JOB HAS OPTIONAL FOAM PANEL CLOSURES ORDERED AT BASE, ATTACH TO INSIDE OF WALL PANEL AT BASE AND FASTEN THROUGH PANEL AND CLOSURE, INTO BASE TRIM. FASTENING PATTERN WILL VAR! PER WALL PANEL TYPE. REFER TO THE WALL PANEL ERECTION DETAIL FOR MORE FASTENING INFO. USE SUPPLIED BASE CORNER PIECES OR FIELD MITRE BASE TRIM AT CORNERS. INSULATION HINT: AT THE BASE, FOLD THE INSULATION VAPOR BARRIER OVER THE FIBER TO HELP PREVENT WATER FROM WICKING. IT IS RECOMMEND THAT THE EXPOSED EDGE OF THE TRIM UPS BE CAULKED IN ORDER TO HELP PREVENT RUSTING. FIELD NOTCH THE BASE TRII (NO FASTENET REQ'D AT LAP POLYUREIHAI TUBE CAULK (rep) *BACK* VERTICAL LEG OF THE BASE BASE TRIM 1' AT ALL TRIM I LAPS TUBE CAULK - (APPLY TO ALL (4) ADJOINING SURFACES) O g _0 U J Of w r Z W Lu m Lu w z Lu w z Lu Of LLJ Tn Lfi w of Ln w>_ c') Q Q D co z LLI w r- w X m wlY LLT)o� W o Lu J m N d r U - rKm x E§oo v-- - to %m_ O Co �;a m'UEm + START (SEE ROOF PLAN) ��E RIB CRIB 0" START FSNOT NOTED z FIELD CUT CRIB AS REVD. H1050 (4" O.C.) 2 1/4" TAPE MASTIC D_ (BETWEEN TRIM AND PANEL) RAKE TRIM MK. H3020 o MK. RTA D- R) _n" Tn -V" ROOF PANEL �\ w rOUTSIDE AT EACH SUPPORTzz RAKE ANGLE (L.L.V.) o_MK. MAR01 o H10603 (12" O.C.) PURLIN D- Rl WALL PANEL PANEL CLOSURE ( FOR SLOPES <\= 141:12 )E* MK. H3400 0 "CLASSIC PANEL MK. H3420 0 "ACCENT PANEL" MK. H3410 0 REV. "CLASSIC PANEL" SCULPTURED RAKE AT "CLASSIC" ROOF SEE WALL SHEETING ERECTION NOTES FOR FASTENER LOCATIONS FOR SLOPES GREATER THAN 1 1/2:12, REFER TO TRIM-2 DETAIL MWrKL.= FOR CLOSURE PARE NUMBERS. HIGH EAVE TRIM Qw MK. HEA_� W O a O J 2" w I Q a o H1060 o_ (12" O.C.) of WALL PANEL H1030 FASTENER (SEE THE END OF CLASSIC ROOF STRUCTURAL PANEL FASTENER SPACING DETAIL) H1050 (12" O.C.) OUTSIDE PANEL CLOSURE APE MASTIC )1TH /T ( 3000)TOPAND BOTTOM "CLASSIC ROOF" EAVE STRUT H1030 FASTENER (SEE THE CLASSIC ROOF STRUCTURAL FASTENER SPACING DETAIL) OUTSIDE PANEL CLOSURE MK. H3400 0 "CLASSIC PANEL" MK. H3420 0 "ACCENT PANEL" MK. H3410 0 "REV CLASSIC PANEL" SCULPTURED EAVE DETAIL WITH CLASSIC ROOF SHEETING SEE WALL SHEETING ERECTION NOTES FOR FASTENER LOCATIONS TRIM-6 H1040 FASTENERS AT 12" O.C. ALTERNATE DETAIL AS REQUIRED NOTE: DOOR EXTERI FOR DOOR RAIL BY WALL RAIL TITHFRC PANEL GIRT JAMB DOOR OR WINDOW OPENING CAP TRIM MK. HTD_ H1040 FASTENERS AT 12" O.C. "CLASSIC" WALL LINER "CLASSIC" LINER PANEL AT JAMB SEE WALL SHEETING ERECTION NOTES FOR FASTENER LOCATIONS TRIM_23 GIRT CAP TRIM MK. HTD__ H1040 FASTENERS AT 12" O.C. "CLASSIC" WALL LINER "CLASSIC" LINER PANEL TERMINATION TRIM_29 LINER PANEL H1040 FASTENERS AT 12" O.C. CAP TRIM HTD__ =LAT STOCK N� _INER MK. z �� =SA01 or FSA04 3 3 -ASTENERS \T 12" O.C. ih o I I M N HEADER O LINER HEADER TRIM w/ FLATSTOCK AT OVERHEAD DOOR TRIM_26 'CLASSIC WALL' H1060 12" 0. OUTSIDE CORNER MK. OCA01— NOTE 1 FILLER TRIM MK. MFB01 (SHOWN) IS NUREQUIRED WHERE START/FlNISH DIMENSION IS LESS THAN OR EQUAL TO 3 1/2". SEE ELEVATIONS GIRTS START FINIS DIMENSION SEE PLAN € � RIB WALL" SUPPORT OUTSIDE CORNER AT "CLASSIC" WALL TRIM-7 LINER PANEL H1040 FASTENERS AT 12" O.C. TRIM HTD__ CD z HEADER OZ w W D- O O 0 Y O 0 LINER HEADER TRIM AT WALKDOOR OR WINDOW OPENINGS TRIM_27 0_ 0 Fw W COVER TRIM CCq_ TSE AT 8 C CCB_ USE AT 10' CET' CDC_ USE AT 12' CEE' CCD_ USE AT 9 1/Y CEE) CS4_ USE AT 8 SIRIICIURAL CSC_ SE AT 12' 51 WMRAL CCD_ USE AT 9 1 2' STRUCTURAL C CCE— USE AT 8" HEADER WRAP CCF_ AT 10' HEADER WRAP CCG_ SE AT 10 HEADER WRAP CCH_ USE EAD AT 9 1 Y HER FOR LINER PANEL, REFERENCE HEAD, SILL OR JAMB DETAILS FOR TYPICAL TRIM PARTS AND USE ATTACHMENT "I ERECTOR ZCS— ERECTOR NOTE: IF LINER PANEL IS NOT IREQUIRED, ATTACH COVER TRIM WITH H1040 12" O.C. CC TRIM TRIM -FORMED CEE CCA_, CCB_, CCC_, OR CCD_ TRIMS) 'TURAL CEE CSA— , CSC_, OR CCD_ TRIMS) SILL SHOWN, HEADER AND JAMBS SIMILAR OR CCH_ TRIMS) TRIM_19 SILL CHANNEL SILL TRIM MK. HTD_ H1040 FASTENERS AT 12" O.C. LINER PANEL 0 U n §a U z z SILL TRIM AT LINER PANEL o o U TRIM_28 z w W p=p W w z W LJLI Z LLJ C/) — � LfLLu n w z M Q Q coW w w�X m� w� U) W oWL _j W mN d r U _ t w - tam E§oo --8. 2 - n ,u gy m_ =- -Et= O -aEm3o- h1 r Nv vEo3v Q - - m'UEm BUILT UP COLUMN (FLANGE EXTENDS PAST INSIDE FACE OF GIRT) BUILT UP COLUMN (FLANGE INSET TO INSIDE FACE OF GIRT) BUILT UP COLUMN (FLANGE EXTENDS PAST INSIDE FACE OF GIRT) BUILT UP COLUMN OR RAFTER (GIRT OR PURUN BYPASSES FRAME) SINGLE OR DOUBLE CEE COLUMN I SINGLE OR DOUBLE CEE COLUMN (FLANGE INSET TO INSIDE FACE OF GIRT) (FLANGE FLUSH TO INSIDE FACE OF GIRT) SINGLE OR DOUBLE CEE COLUMN (FLANGE EXTENDS PAST INSIDE FACE OF GIRT) SINGLE CEE COLUMN (GIRT BYPASSES FRAME) BUILT UP COLUMN (FLANGE FLUSH TO INSIDE FACE OF GIRT) PARTS LEGEND MAG01 GIRT ANGLE WITH (2) H 1020 FASTENERS MAG02 GIRT ANGLE WITH (2) H 1020 FASTENERS HTD__ H1040 EACH SUPPORT, H1060 12" O.C. BETWEE SINGLE —DOUBLE 12" CEE COLUMN (FLANGE EXTENDS PAST INSIDE FACE OF GIRT) "CLASSIC" LINER TERMINATION DETAILS AT INTERMEDIATE COLUMNS H1030 STRUCTUPi FASTENERS. SEE "CLASSIC ROOF ERECTION NOTES" DETAIL FOR SPACI APE MASTIC 3000) )LAPS STANDARD "CLASSIC" ROOF LAP TRIM_171 EXTERIOR PANEL FOUNDATION WALL BY OTHERS — LINER PANEL BASE ANGLE MK. MAR02 (S.L.V.) WHEN BASE CHANNEL IS NOT UTILIZED. H1040 FASTENERS AT 12" O.C. POWDER —ACTUATED PIN, CONCRETE NAIL, OR EQUIVALENT AT 3'-0" O.0 (NOT INCLUDED) v ERECTOR NOTE: WHEN FLANGE THICKNESS EXCEEDS 1/2', A 5/32' PILOT HOLE IS REQUIRED AT RAKE ANGLE TO RAFTER ATTACHMENT. ENDWALL VARIES CENTERLINE OF RAFTER 0 0 Z K o' 0 m a 1/2" MIN. - 3 1/2" MAX. PURUN w ENDWALL RAFTERf—H1060 FASTENERS AT 36" O.C. 0 RAKE ANGLE CAP FLASH MK. CTA02 o_MK. MAL01 (S.L.V.)FASTENER MK.H1040 FASTENERS H1070 ® 60" O.C.AT 12" O.C. (SEE ERECTOR NOTE) ENDWALL J GIRT Il II I�LINE j GIRT DEPTH LINER U I (HOLD) U LINER PANEL BASE LINER PANEL AT POST & BEAM ENDWALL I =_ TRIM_38 0 '"S� G"� TRIM_40 STEEL LINE I (HOLD) EAVE STRUT ------- SHOWN, MEMBER VARIES.(REFERENCE THE SECONDARY LOW EAVE MEMBER OPTION DETAIL FOR ALTERNATIVE MEMBERS) H1020 FASTENERS AT 60" O.C. — EAVE ANGLE (S.L.V.) MK. MAL01 AT 8", 9.5" OR 10" GIRTS MK. MAL15 AT 12" GIRTS STEEL LINE CAP TRIM MK. HTD121 (ERECT PRIOR TO LINER PANEL) EAVE STRUT {1) H1040 FASTENER H1020 FASTENERS L AT EACH END OF CAP AT 60" O.C. TRIM (1) H1040 FASTENER -H1040 FASTENERS AT EACH END OF AT 12" O.C. THE CAP TRIM EAVE ANGLE MK. MAF01 0 S 1:12 AND 8", 9.5" or 10" GIRTS MK. TXP_ 0 > 1:12 —WALL LINER OR 12" GIRTS GIRT (HOLD) PURLIN CAP TRIM MK. HTD121 (ERECT PRIOR TO LINER PANEL) H1040 FASTENERS AT 12" O.C. WALL LINER LINER PANEL ® LOW EAVE LINER PANEL AT HIGH EAVE TRIM_32 a 1:12 ROOF SLOPE TRIM_44 0 �- 1:12 ROOF SLOPES TRIM_48 W Oo coo zOf W= 07 X ZW W ~ Z 0 0 W c M W z U � W W L r a rL Z 0 I= w J W w W J � W W � 0 cLID Q Q co 00 r- H Waf z � O _ d w - tam x E§oo -- - n =Eta O -aEm3o- h _ Nv Q - - _vE rn3ao m'UEm 1/4" L� WIDE MAX. 0 SLIT FLAT OF JAMB TRIM PANEL SLIT STEP 3 SLIT PANEL 2" AND SLIDE ONTO HEAD TRIM (SEE ABOVE) STEP 3 0 GIRT ��a,e FASTENER KEY STITCH FASTENER = H106_ DOOR / WINDOW "ACCENT PANEL" OPENING STRUCTURAL FASTENER = H104_ WITH COLD -FORM STRUCTURAL FASTENER = H1070 WITH HOT -ROLLED JAMB TRIM MK. JTA STRUCTURAL FASTENER GIRT JAMB 12" O.C. GIRT JAMB DOOR / WINDOW " REVERSE _"CLASSIC WALL" PANEL DOOR WINDOW CLASSIC WALL" OPENING 17 OPENING STRUCTURAL FASTENER) \—JAMB TRIM 12" O.C. MK. JTD NOTE: FIELD TRIM LEG AS REQUIRED ALTERNATE DETAIL 1 WALL PANEL CAULK FROM EDGE OF TRIM TO FIRST MAJOR RIB MK. H3152 STEP 4 HEAD TRIM. MK. HTA_ STEP 1 JAMB TRIM MK. JT T__�FSTEP 2 DOOR FRAMED OPENING TRIM DETAIL o o FOR ALL ANDARD WALL PANEL TYPES co LEFT HAND TSHOWN, RIGHT HAND SIMILAR TRIM 98 END CLOSURE DETAIL OUTSIDE CORNER TRIM INSIDE CORNER TRIM END CLOSURE MK. H4220 MK. H4200 MK. H4210 (POLAR WHITE). APPLY TUBE CAULK (H3152) ALL AROUND AND INSERT INTO END OF BSCOI TRIM AT FRAMED OPENINGS, WALKDOORS, AND _ EXISTING BUILDINGS. ERECTOR NOTE: UNTIL WALL PANELS ARE INSTALLED, (3) H1040 SCREWS ARE TO BE USED FOR TEMPORARY INSTALLATION OF THE BASE TRIM. INSIDE PANEL CLOSURE MK. H3410 0 "CLASSIC PANEL" WALL PANEL MK. H3430 0 "ACCENT PANEL" MK. H3400 0 REV" CLASSIC PANEL" BASE MEMBER: ANGLE, CHANNEL z OR OTHER. 0 0 (SEE ELEVATIONS) w SEALANT o a (NOT BY METAL BUILDING SUPPLIER) W-i = k BASE ANGLE 3 in TRIM MK. BSC01 BASE TRIM AT WALL DELETION SEE WALL SHEENNG ERECTION NOTES FOR FASTENER SPACING TRIM_722 rrr HI STRUCTURAL FASTENERS JAMB TRIM 12" O.C. MK. JTA JAMB TRIM STEP 2 NOTE: FIELD CUT PANELS AS REQUIRED TRIM OVERHANG nrrmv 1 JAMB TRIM — Lj INSIDE PANEL CLOSURE MK. H3410 0 "CLASSIC PANEL" MK. H3430 0 "ACCENT PANEL" MK. H3400 0 REV" CLASSIC PANEL" STRUCTURAL FASTENER 12" O.C. 0 "ACCENT" 12" O.C. 0 "REV. CLASSIC" 6" O.C. 0 "CLASSIC" HEAD TRIM MK. HTA_ HEAD TRIM STEP 1 1/4" o WIDE MAX. SLR FLAT OF ieuo Tow PANEL SLIT STEP 4 HEADER AND SILL SHOWN SLIT PANEL 2" AT HEAD AND SILL TRIM AND SLIDE ON (SEE ABOVE) STEP 4 0 PANEL GIRT /-UAMB FASTENER KEY STITCH FASTENER = H106_ "ACCENT PANEL" DOOR / WINDOW STRUCTURAL FASTENER = H104_ OPENING WITH COLD -FORM STRUCTURAL FASTENER = H1070 WITH HOT -ROLLED lz rl JAMB TRIM U U MK. JTA STRUCTURAL FASTENER GIRT JAMB m m 12" O.C. GIRT JAMB DOOR / WINDOW OPENING REVERSE "CLASSIC WALL" PANEL "CLASSIC WALL" w DOOR WINDOW s OPENING o m a m m STRUCTURAL FASTENER J \-JAMB TRIM 12" O.C. MK. JTD NOTE: FIELD TRIM LEG AS REQUIRED ALTERNATE DETAIL 1 WALL PANEL CAULK FROM EDGE OF TRIM TO FIRST MAJOR RIB MK. H3152 STEP 5 HEAD TRIM. MK. HTA_ STEP 1 'JAMB TRIM MK. JT STEP 3 0 `SILL TRIM MK. STA.— SEE PREP SKETCH TO THE RIGHT STEP 2 CAULK SLIT LINE, MK. H3152 STEP 5 WINDOW FRAMED OPENING TRIM DETAIL o FOR ALL STD WALL PANEL TYPES. TYPICAL INSTALL TRIM 99 C9 LEFT HAND SHOWN, RIGHT HAND SIMILAR STRUCTURAL FASTENER JAMB TRIM `c o 12" O.C. MK. JTA cLCi Q m JAMB TRIM STEP 3 NOTE: FIELD CUT PANELS AS REQUIRED HEAD TRIM � TRIM OVERHANG WALL PANEL HEADER JAMB TRIM — " `INSIDE PANEL CLOSURE MK. H3410 0 "CLASSIC PANEL" /MK. H3430 0 "ACCENT PANEL" MK. H3400 0 REV" CLASSIC PANEL" STRUCTURAL FASTENER 12" O.C. "ACCENT" 12" O.C. "REV. CLASSIC" 6" O.C. "CLASSIC" HEAD TRIM z z MK. HTA_ V 0o HEAD TRIM STEP 1 z o Oo O H JAMB TRIM INDICATED BY DASHED 2 U LINE. THE SILL TRIM EXTENDS 2" (A LLI PAST EACH SIDE OF THE OPENING. ~ THE JAMB TRIM THEN RESTS ON W = m W ~ w z TAB UP THE SILL TRIM. TAB LEG OF SILL x TRIM BEHIND THE JAMB TRIM TO z LLI W o HELP SHED WATER. W Of W SILL TRIM MK. STA _ Z W SfTTCH FASTENERS 12" O.C. Lo ? w i coLo SILL CHANNEL STRUCTURAL FASTENERS "ACCENT" Z W m X w 12" O.C. — ~ W WALL PANEL 12" O.C. "REV. CLASSIC" Lc.)of oLU T-�J D_ z 6" O.C. "CLASSIC" a o CUT OFF EXTRA1„ TOP VIEW Q 1 3/8" FRONT TOP FRONT f d w rKm x NA -- - n _O SILL TRIM-=�3-��@a- 4-- CLEAR O OPENING -�Er ody== rn _ a�H3w SILL TRIM-1 REP STEP 2 Mi E1 E 3` m'UEm J w z LL J J w 0 w 0 1- LOW EAVE STEEL LINE INSIDE PANEL CLOSURE MK. H3410 WITH 3/4" TAPE MASTIC END OF PANEL 7 1 4" (MK. H3000) TOP AND BOTTOM CAP TRIM MK. "CLASSIC" ROOF PANEL CTA03 FASTEN INSULATION WITH H1020 3/4" TAPE FASTENER & H2200 INSULATION MASTIC MK. WASHER 12" O.C. (AT HIGH RIB) H3000 H1030 FASTENER (SEE THE CLASSIC ROOF STRUCTURAL FASTENER SPACING DETAIL) H1060 (1) H1020 FASTENER AT EACH FASTENERS END OF THE CTA03 TRIM AT 12" O.C. EAVE STRUT SHOWN, MEMBER VARIES (REFERENCE THE SECONDARY LOW SCULPTURED EAVE MEMBER OPTION DETAIL FOR EAVE TRIM ALTERNATE MEMBERS) MK. SET01 MK. H10FASTENERS OUTSIDE PANEL CLOSURE "CLASSIC MK. H3400 @ PANEL" FA FA MK. H3420 @ "ACCENT PANEL" AT 12" O.C. MK. H3410 @ REV" CLASSIC PANEL" SECTION VIEW WALL PANEL 3" AT 1 /2:12 ROOF SLOPE 3 1/2" AT 1:12 ROOF SLOPE �k 4 1 /8" AT 2:12 ROOF SLOPE 4 5/8" AT 3:12 ROOF SLOPE 5 1 /8" AT 4:12 ROOF SLOPE 'E MASTIC )0 I MK. CTA03 BUT SHOWN, VARIES RED EAVE SET01 3W ROOF RAKE MK. R WALL CORN[ CORN[ MK. H-rvvv SCULPTURED EAVE TRIM SPLICE APPLY A CONTINUOUS BEAD OF TUBE CAULK (MK. H3152) TO THE END OF THE ADJOINING TRIM PIECE AND LAP 1". FASTEN WITH (4) COLORED POP RIVETS (MK. H1100) AS SHOWN. FOLLOW THE CLASSIC ROOF ERECTION MANUAL WITH THE FOLLOWING EXCEPTIONS AT SCULPTURED EAVE TRIM APPLICATIONS: 1) THE CTA03 CAP TRIM ON THE EAVE STRUT MUST BE m ERECTED PRIOR TO INSTALLING THE ROOF PANEL AND THE e e SCULPTURED EAVE TRIM. (SEE THE CLASSIC ROOF ERECTION m MANUAL). N 0 2) INSULATION MUST BE INSTALLED PRIOR TO INSTALLING o THE ROOF PANELS. INSULATION IS NOT SHOWN IN THIS DETAIL FOR CLARITY. (SEE THE CLASSIC ROOF ERECTION o MANUAL FOR PROPER INSTALLATION OF THE INSULATION) m C L � 4C1 _ Q G] 3) INSTALL 3/4" TAPE MASTIC (MK. H3000) TO THE SHORT VERTICAL LEG OF THE CTA03 CAP TRIM. EXTEND THE SCULPTURED EAVE TRIM SET01, 2 1 /4" PAST THE s ENDWALL STEEL LINE (1" PAST THE EDGE OF THE WALL CORNER TRIM). COPE THE BOTTOM VERTICAL LEG FLUSH WITH THE EDGE OF THE CORNER TRIM. INSTALL OUTSIDE$ CLOSURE AS SHOWN (IF REQUIRED) THEN FASTEN THE TRIM TO THE WALL PANEL AND CAP TRIM WITH H1060 s s FASTENERS AT 12" O.C. =5 4) APPLY A CONTINUOUS BEAD OF TUBE CAULK (MK. 3.42 s H3152) AROUND THE PERIMETER OF THE RCA__ CORNER = ld'i CAP, CLOSE TO THE INSIDE EDGE OF THE CAP. 5) INSERT THE CORNER CAP INTO THE SCULPTURED RAKE TRIM, LEAVING 1/2" EXPOSURE ALL AROUND. FASTEN WITH (3) H1100 COLORED POP RIVETS AT FRONT ONLY. CAP TRIM MK. CTA03 6) INSTALL THE RAKE CAP AT THE RAKE EDGE OF THE 0 SCULPTURED EAVE TRIM & 1/2" FROM THE FIRST VERTICAL z FACE OF THE SCULPTURED EAVE (AS SHOWN AT LEFT). UTILIZE TUBE CAULK (MK. H3152) AROUND THE PERIMETER 0-zz 0- p OF EDGE OF THE RAKE CAP. = H U cD w 3/4" TAPE MASTIC z cw X W w MK. H3000 7) APPLY A BEAD OF TUBE CAULK (MK. H3152) 1 1/2" Lu jjj FROM THE FACE OF THE EAVE TRIM ALONG THE RAKE SIDE w z w p OF THE CORNER CAP. THIS BEAD SHOULD INCLUDE BOTH cn SCULPTURED EAVE THE TOP & BOTTOM EDGES OF THE CORNER CAP. � w TRIM MK. SET01 w co w Z ` ¢ m coQ�� w� w�Lo w�X mg FIELD CUT PANEL 8) INSTALL THE RAKE TRIM RTA__ PER THE CLASSIC ROOFLu o ERECTION MANUAL, 1/2" FROM THE FACE OF THE SCULPTURED EAVE TRIM. RAKE CAP MK. RCA01 (LEFT AS SHOWN) 9) FASTEN THE CORNER CAP AND THE RAKE CAP, AS MK. RCA02 (RIGHT) SHOWN AT LEFT, WITH (15) COLORED POP RIVETS (MK. H 1100). ISOMETRIC VIEW AT LOW EAVE ISOMETRIC VIEW AT CORNER o POP RIVET 0 SCULPTURED EAVE TRIM w/ CLASSIC ROOF U SEE WALL SHEETING ERECTION NOTES 0 FOR WALL PANEL FASTENER LOCATIONS TRIM_850 _ w tFm = E 3'm lH -v m�im � _Et= 0 - -.E� -