HomeMy WebLinkAboutREVISIONS 2 - 21-00694 - 240 E Moody - Wendy's - New BuildingGENERAL NOTES A. PAY ALL FEES AND ARRANGE FOR EXECUTION OF ALL TAPS, METERS WITH REQUIRED ENCLOSURES (IF ANY), AND APPURTENANCES INHERENT TO THE INSTALLATION OF PLUMBING SERVICE. B. PROVIDE ALL LABOR, EQUIPMENT, AND MATERIALS NECESSARY TO EXECUTE THE PLUMBING WORK INDICATED ON THE DRAWINGS AS SPECIFIED, AND AS REQUIRED BY LOCAL CODES AND ORDINANCES. PLUMBING WORK SHALL INCLUDE ALL PIPING FOR DOMESTIC HOT AND COLD WATER LINES, VENT AND SANITARY LINES, HOOK-UP OF ALL FIXTURES SCHEDULED ON THE DRAWINGS, AND INSULATION OF DESIGNATED PIPING. WORK SHALL ALSO INCLUDE ALL GAS PIPING AND EQUIPMENT CONNECTIONS WHERE REQUIRED. INCLUDE ALL ITEMS SUCH AS FITTINGS NOT MENTIONED BUT UNDERSTOOD TO BE NECESSARY TO COMPLETE THE PLUMBING SYSTEM. COORDINATE ALL WORK WITH OTHER CONTRACTORS. C. PROVIDE FOR DRAINING WATER SYSTEM AND CAP ALL STUBS UNTIL FINISH WORK IS INSTALLED. INSTALL DRAIN VALVE AT WATER METER WITH 3/4" HOSE THREAD AND VACUUM BREAKER. D. PROVIDE VALVES ON WATER SUPPLIES TO EACH FIXTURE & EQUIPMENT. VALVES SHALL BE 1/4 TURN SHUT-OFF VALVES. E. INSULATE ALL PIPING PER SPECIFICATIONS. F. PLUMBING FIXTURES SHALL BE PROVIDED WHERE SHOWN ON DRAWINGS. FIXTURE FITTINGS AND EXPOSED FIXTURE PIPING SHALL BE BRASS CHROMIUM PLATED. TRAPS SHALL BE CAST BRASS. FIXTURES SHALL BE EQUAL IN ALL RESPECTS TO FIXTURES SPECIFIED. G. PROVIDE ROUGH-IN AND FINAL CONNECTIONS OF REQUIRED WASTE, VENT, AND WATER SUPPLY PIPING. H. THIS CONTRACTOR SHALL GUARANTEE ALL WORK INSTALLED UNDER THE CONTRACT TO BE FREE FROM DEFECTIVE WORKMANSHIP AND MATERIALS, (USUAL WEAR IS EXPECTED), AND SHOULD DEFECTS DEVELOP WITHIN A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF THE BUILDING BY THE OWNER, THIS CONTRACTOR SHALL REPAIR AND/OR REPLACE DEFECTIVE ITEMS AND ALL DAMAGE RESULTING FROM FAILURE OF THESE ITEMS, AT NO EXPENSE WHATSOEVER TO THE OWNER I. THE DIRECTION OF THE SANITARY MAIN AND THE LOCATION OF THE GREASE INTERCEPTOR SHALL BE COORDINATED WITH CIVIL DRAWINGS PRIOR TO ROUGH-IN. J. PROVIDE PROVENT TRAP GUARD (OR APPROVED EQUAL) AT ALL FLOOR DRAINS. PROVIDE TRAP PRIMERS ON FLOOR DRAINS ONLY IF REQUIRED BY AUTHORITY HAVING JURISDICTION (AHJ). IF AHJ REQUIRES TRAP PRIMERS, LAYOUT DISTRIBUTION TO CONNECT MULTIPLE FLOOR DRAINS TO ONE TRAP PRIMER. K. COORDINATE LOCATION AND ROUGH-IN HEIGHT OF KITCHEN EQUIPMENT WITH OWNER AND MILLWORK PRIOR TO ROUGH-IN. L. PROVIDE WATER HAMMER ARRESTORS AT END RUN OF ALL WATER PIPING. SIZE AND LOCATE AS RECOMMENDED BY PLUMBING AND DRAINAGE INSTITUTE STANDARD PDI-WH201, AND AS RECOMMENDED BY THE MANUFACTURER. M. ALL PIPING (GAS AND WATER) SHALL BE CONCEALED IN WALL SPACE WHEN POSSIBLE, UNLESS NOTED OTHERWISE. N. DAMAGES TO EXISTING WALLS, FLOORS, FINISHES ETC. BY THIS CONTRACTOR SHALL BE REPAIRED AT THIS CONTRACTOR'S EXPENSE. O. WATER HEATER, WATER METER AND BACKFLOW PREVENTER SHALL BE INSTALLED TO MEET ALL STATE, COUNTY AND LOCAL JURISDICTION CODES. P. ON ALL SYNFLEX LINE INSTALLATIONS (EXCEPT DRINK STATIONS AND COFFEE BREWER) TRANSITION TO COPPER AT TOP OF WALL, AND ROUTE DOWN INSIDE WALL AND THEN THROUGH WALL TO EXPOSED SHUT OFF VALVE. DRINK STATIONS WILL HAVE SYNFLEX LINES FROM FILTER TO UNIT INSTALLED BY BEVERAGE SYSTEM INSTALLER. Q. 3 COMP SINK, COMBI OVEN AND 2 AREA FLOOR DRAINS BETWEEN HOOD AREA SHALL BE ROUTED TO GREASE WASTE LINE. ALL OTHER DRAINS SHALL BE ROUTED TO BUILDING SANITARY. R. ALL WATER SUPPLY LINES, VENT STACK LINES, SANITARY LINES, AND OTHER EXPOSED PLUMBING LINES SHALL BE COMPLETELY SEALED AT ALL WALL PENETRATIONS. PROVIDE CHROME ESCUTCHEON PLATE SEALED TO WALL WITH SILICONE SEALANT. S. SEE CONNECTION SCHEDULE FOR ALL INDIVIDUAL PIPE SIZES. WATER CALCULATION CRITICAL ELEVATIONS AND DISTANCES: FEET ELEVATION OF CONTROLLING FIXTURE (WATER CLOSET)4.0 ELEVATION OF FINISHED FLOOR 0.0 ELEVATION OF WATER MAIN -4.0 ELEVATION OF WATER ENTRY -4.0 VERTICAL DIST. FROM WATER MAIN TO CONTROLLING FIXTURE 8.0 SYSTEM PRESSURE REQUIREMENTS:PSI ELEVATION (VERTICAL DISTANCE) X 0.434 PSI/FT 3.5 PRESSURE NEEDED AT CONTROLLING FIXTURE 20.0 BACKFLOW PREVENTER: 1-1/2" AT 66 GPM 8.0 WATER METER: 1-1/2" AT 66 GPM 10.0 TOTAL 41.5 PIPE RUNS:FEET EXTERIOR, MAIN TO BUILDING ENTRY 100.0 EXTERIOR, VERTICAL RISE 0.0 INTERIOR, ENTRY TO CONTROLLING FIXTURE 60.0 INTERIOR, VERTICAL RISE 8.0 ALLOWANCE FOR FITTINGS, ETC. (LENGTH X 0.25)42.0 TOTAL 210.0 SYSTEM PRESSURE DATA: PSI STREET PRESSURE 80.0 SYSTEM PRESSURE REQUIRED 41.5 PRESSURE AVAILABLE FOR (PIPING) FRICTION LOSS 38.5 PIPE SIZING:PSI/100' PRESSURE AVAILABLE X 100 / (TOTAL PIPE RUN)18.3 * NOTE: ALL PIPING IS SIZED FOR 5 PSI/100' PRESSURE LOSS REFER TO WENDY'S CONSOLIDATOR LIST TO OBTAIN BUILDING MATERIAL QUOTES. REFER TO WENDY'S APPROVED SUPPLIER LIST FOR PHONE NUMBERS AND CONTACTS. ATTENTION ALL BIDDERS REMARKS (#) FIXTURE & EQUIPMENT CONNECTION SCHEDULE SY M B O L QU A N T I T Y GENERAL FIXTURE DESCRIPTION DOMESTIC WATER SANITARY NATURAL GAS US E D C O O K I N G O I L REMARKS (#) FI L T E R E D W A T E R - F C W 1 FI L T E R E D W A T E R - F C W 2 FI L T E R E D W A T E R - F C W 3 FI L T E R E D W A T E R - F C W 4 CO L D W A T E R HO T W A T E R ( 1 4 0 ° ) HO T W A T E R ( 1 1 0 ° ) MO U N T I N G H E I G H T DR A I N L I N E S I Z E TR A P FI X T U R E D R A I N DI R E C T / I N D I R E C T ( D / I ) SA N I T A R Y / G R E A S E ( S / G ) VE N T MO U N T I N G H E I G H T CO N N E C T I O N S I Z E BT U L O A D PLUMBING FIXTURES WC 2 WATER CLOSET (ACCESSIBLE)114"(1)4" INT 4" D S 2" FL (3), (6) LAV-1 2 LAVATORY 12"12"(1)112"112"112"D S1 12"(1) (3), (6) LAV-2 1 LAVATORY 12"12"(1)112"112"112"D S1 12"(1) (3), (6) FPWH 2 FROST PROOF WALL HYDRANT 3 4"18"(3), (6) PLUMBING DRAINS FD 11 FLOOR DRAIN 3" 3" * 1 12"FL (3), (8), (9) FS-1 4 FLOOR SINK 3" 3" * 1 12"FL (3), (8), (9) FS-2 1 FLOOR SINK 3" 3"*112"FL (3), (8), (9) HD 1 HUB DRAIN 3" 3" * 1 12" 12" (3), (8), (9) KITCHEN EQUIPMENT - FRONT COUNTER E2302 1 BACK COUNTER HAND SINK 12"12"14"2"112"112"D S1 12" 12" (4), (6), (8), (9) KITCHEN EQUIPMENT - BEVERAGE LINE A0105 1 BEVERAGE SYSTEM (DRIVE-THRU)12"14"IS (4), (14), (15) A0608 1 COFFEE BREWER 12"14"(4), (10), (11) E4006 1 DRIVE-THRU HAND SINK ASSEMBLY 12"12"14" 2"112"112"D S1 12"(4), (8), (9) KITCHEN EQUIPMENT - FRYLINE K1401 1 COMBI OVEN 12"12" 30" 3" 3" I G 1 12"(5), (10), (11) KITCHEN EQUIPMENT - PREP AREA / WAREWASH A0801 1 TEA BREWER * 12" 72" (4), (10), (11) T1213 1 CHEMICAL BLEND STATION (FOR T2011)12"12"54"(4) T0902 1 1 COMP PREP SINK 12"12"14"(4), (6), (7), (8), (9) T2011 1 3 COMP SINK 12"12"14"(4), (6), (7), (8), (9) T2061 1 WAREWASH MACHINE 12"3 4"61.75" 3" 3"2" I G 1 12"(4), (6), (7), (8), (9), (10) KITCHEN EQUIPMENT - HAND SINK T2703 1 HAND SINK 12"12"14"2"112"112"D S1 12" 12" (4), (6), (8), (9) KITCHEN EQUIPMENT - DRINK EQUIPMENT QP0909 1 ICE MAKER - KITCHEN 12" 72" 3" 3" 3 4"I S1 12"(4), (6), (7), (10) T2212 1 WATER TREATMENT UNIT 3 4"85"(4), (11), (13) KITCHEN EQUIPMENT - MOP SINK / CLEANING EQUIPMENT T0303 1 MOP SINK FAUCET (FOR T0602 - LOWER)12"12"36"(4), (6) T0304 1 MOP SINK FAUCET (FOR T0602 - UPPER BLEND CENTER)12"12"54"(4), (6) T0602 1 MOP SINK 3" 3" 3" D S 1 12"FL (4), (6) T1212 1 CHEMICAL BLEND CENTER 12"12"54"(4) T2213 1 REVERSE OSMOSIS SYSTEM 12"12"85"(5) A0304 1 BAG-IN-BOX 12"85"(5), (11), (12) KITCHEN EQUIPMENT - DRINK STAND A0202 2 BEVERAGE SYSTEM (SELF-SERVE - DINING ROOM)12"14"IS (4), (14), (15) QP0222 2 ICE MAKER (CUBER) - DINING ROOM 12" 96" 3" 3" 3 4"I S1 12"(4), (6), (7), (10) *VERIFY QUANTITIES WITH ARCHITECTURAL EQUIPMENT PLAN AND SCHEDULE.* 1. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2. PLUMBING FIXTURE PROVIDED BY PLUMBING INSTALLER. REFER TO PLUMBING FIXTURE SCHEDULE 3. EQUIPMENT FURNISHED BY OTHERS. 4. PLUMBING INSTALLER TO MAKE FINAL CONNECTIONS TO EQUIPMENT. 5. FINAL CONNECTION TO EQUIPMENT BY OTHERS. 6. PROVIDE VALVE AT EACH CONNECTION TO EQUIPMENT. 7. PLUMBING CONTRACTOR TO PROVIDE INDIRECT DRAIN TO FLOOR DRAIN OR SINK. 8. VERIFY DIRECT OR INDIRECT WASTE CONNECTION PER LOCAL CODE REQUIREMENTS. 9. VERIFY SANITARY OR GREASE WASTE CONNECTION PER LOCAL CODE REQUIREMENTS. 10. SHUTOFF VALVE AND FLEX CONNECTOR LINES TO PRE-RINSE ARE PROVIDED WITH FIXTURE. 11. PROVIDE WITH BACKFLOW PROTECTION PER BACKFLOW PREVENTOR SCHEDULE. COORDINATE BACKFLOW INSTALLATION WITH KITCHEN EQUIPMENT PROVIDER AND BEVERAGE INSTALLER. 12. PROVIDE WITH WATTS NO. SS009 BACKFLOW PREVENTER WHEN LOCAL JURISDICTION REQUIRES A HIGHER LEVEL OF PROTECTION THAN PROVIDED BY THE INTEGRAL ASSE 1022 DOUBLE CHECK VALVE. 13. PLUMBING INSTALLER TO RUN WATER LINE TO FILTRATION SYSTEM WITH FINAL CONNECTIONS BY BEVERAGE INSTALLER. 14. BEVERAGE INSTALLER TO ROUTE LINE TO POINT OF USE AND PLUMBING INSTALLER TO MAKE FINAL CONNECTION. 15. WATER SUPPLY LINE IS PART OF THE BEVERAGE BUNDLE. PUMP SCHEDULE SYMBOL MANUF. MODEL GPM HEAD (FT)VPHA W NOTES (#) RCP GRUNDFOS ALPHA2 5 12 115 1 0.65 5 - 65 (1) NOTES: 1.RECIRCULATING PUMP: BRONZE BODY RECIRCULATING PUMP WITH "AUTOADAPT" VARIABLE SPEED MOTOR, INSTALL NEAR WATER HEATER PER MANUFACTURER'S INSTRUCTIONS. PROVIDE WITH ALPHA 3-PRONG PLUG AND COORDINATE CONNECTION WITH ELECTRICAL CONTRACTOR. PROVIDE WITH HONEYWELL L6006C SURFACE MOUNT AQUASTAT SET TO 5°F BELOW WATER HEATER OPERATING TEMPERATURE. WSFU CALCULATIONS FIXTURE QTY.WSFU TOTAL WATER CLOSET (FLUSH)21020 LAVATORY 3 2 6 MOP BASIN 1 33 HAND SINK 3 2 6 1-COMP SINK 1 4 4 3-COMP SINK 1 44 WAREWASH 1 3 3 BEVERAGE STATION 3 1 3 BAG-N-BOX 1 33 ICE MAKER 3 1 3 COMBI-OVEN 1 1 1 COFFEE BREWER 1 0.5 0.5 TEA BREWER 1 0.5 0.5 HOSE BIBB 2 36.0 *WSFU VALUES GIVEN PER IPC* WSFU TOTAL 63.00 DFU CALCULATIONS FIXTURE QTY.DFU TOTAL WATER CLOSET (FLUSH)248 LAVATORY 3 1 3 MOP BASIN 1 2 2 HAND SINK 3 1 3 3" HUB DRAIN 1 5 5 3" FLOOR SINK 7 5 35 3" FLOOR DRAIN (EMERGENCY)9-- *DFU VALUES GIVEN PER IPC* DFU TOTAL 56.0 EXPANSION TANK SCHEDULE SYMBOL MANUF.MODEL GAL. ACCEPT. GAL. CONN. LOC. CONN. SIZE MOUNTING NOTES (#) ET-1 AMTROL ST-8 4.4 3.2 TOP 3 4"ABOVE WH-1 (1), (2) NOTES: 1. EXPANSION TANK: STEEL SHELL, HEAVY DUTY BUTYL NSF/ANSI 61, FACTORY PRECHARGED TO 50 PSIG. MAX OPERATING TEMPERATURE 200°, MAX OPERATING PRESSURE 150 PSI, 1 YEAR MANUFACTURER'S WARRANTY. INSTALL PER MANUFACTURER'S INSTRUCTIONS. 2.FIELD CHARGE EXPANSION TANK TO SYSTEM PRESSURE BEFORE CONNECTION TO DOMESTIC WATER SYSTEM. FIELD VERIFY PRESSURE REQUIREMENTS. GREASE INTERCEPTOR SIZING FIXTURE QTY.FLOW RATE (2 MIN) FLOW RATE (1 MIN) FLOOR DRAIN 3 0.00 0.00 FLOOR SINK 8 0.00 0.00 MOP BASIN 1 9.35 18.70 THREE COMP SINK 1 30.00 60.00 DISHWASHER 1 5.00 10.00 TOTAL FIXTURE FLOW RATE 44.35 CALCULATED FLOW RATE (GPM) PIPE SIZE FLOW RATE (4 IN)75 44.35 [(CU IN / 231) = GAL X 0.75 / 2 MIN = 2 MIN FLOW RATE] NUMBER OF SEATS 55 GREASE PRODUCTION (LBS OF FOG) AVG. MEALS PER SEAT PER DAY 4 693.0 FAST FOOD - FULL PREP (HIGH / NO FLATWARE: 0.035 LBS PER SERVING)0.035 DAYS BETWEEN PUMP OUTS 90 [SERVINGS PER DAY X GREASE PRODUCTION VALUE X DAYS BETWEEN PUMP-OUTS = GREASE OUTPUT] BACKFLOW PREVENTER SCHEDULE LOCATION TAG MODEL ASSE MAIN WATER SUPPLY RPZ WATTS LF009-QT-S 1013 CARBONATOR DCV-1 WATTS SD-3 1022 SODA DISPENSORS DCV-2 WATTS SD-2 1022 OTHER EQUIPMENT DCV-3 WATTS SERIES 7 1024 NOTE: VERIFY BACKFLOW VALVE REQUIREMENTS AND APPROVAL FOR ALL EQUIPMENT WITH AUTHORITIES HAVING JURISDICTION PRIOR TO INSTALLATION. GAS FIRED WATER HEATER SCHEDULE SYMBOL MANUF. MODEL GAL. BTU GAS PRESSURE RECOVERY (GPH/100°F) SET POINT (°F) NOTES (#) WH-1 BRAFDORD WHITE EF-100T-1 99E-3N 100 199,999 7" W.C. 235 140 (1), (2) NOTES: 1.GAS FIRED WATER HEATER: THREE YEAR TANK/PARTS WARRANTY, GLASS LINED STEEL TANK, 150 PSI WORKING PRESSURE, THERMAL EFFICIENCY OF 97% MEETING CURRENT EDITION OF ASHRAE 90.1B AND LOCAL ENERGY CONSERVATION REQUIREMENTS. PROVIDE T&P RELIEF VALVE. 2.FURNISH WITH EXPANSION TANK AS SPECIFIED ON PLANS. ELECTRIC WATER HEATER SCHEDULE SYMBOL MANUF.MODEL GAL. KW V PH FLA RECOVERY (GPH/90°F) SET POINT (°F) NOTES (#) WH-2 BRADFORD WHITE LE16U3 6 6 208 1 28.8 25 140 (1), (2) NOTES: 1.ELECTRIC WATER HEATER: THREE YEAR TANK/PARTS WARRANTY, GLASS LINED STEEL TANK, 150 PSI WORKING PRESSURE, MEETING CURRENT EDITION OF ASHRAE 90.1B AND LOCAL ENERGY CONSERVATION REQUIREMENTS (SMALL TANK WATER HEATERS BELOW 20 GALLONS ARE EXEMPT FROM NAECA REQUIREMENTS AND ASHRAE 90.1). PROVIDE T&P RELIEF VALVE. 2. FURNISH WITH EXPANSION TANK AS SPECIFIED ON PLANS. BV BALL VALVE GW D G UCO FW SANITARY WASTE (SAN) - BELOW SLAB/GRADE PLUMBING VENT (V) - BELOW SLAB/GRADE GREASE WASTE (GW) - BELOW SLAB/GRADE USED COOKING OIL (UCO) PLUMBING VENT (V) CONDENSATE LINE (D) HOT WATER RETURN (HWR) 140°, 120° GAS LINE (G) NSF 61 TUBING (NSF) [BY OTHERS] FILTERED WATER SUPPLY (FW) HOT WATER (HW) 140°, 120° COLD WATER (CW) - BELOW SLAB/GRADE COLD WATER (CW) NSF BFP RI BACKFLOW PREVENTER ROUGH-IN AFF/AFG FCO/ECO VTR IW WCO/CO ABOVE FINISHED FLOOR/GRADE FLOOR/EXTERIOR CLEANOUT WALL CLEANOUT/ CLEANOUT VENT THRU ROOF INDIRECT WASTE TYPICALTYP AHJ UNO AUTHORITY HAVING JURISDICTION UNLESS NOTED OTHERWISE ABBREVIATIONS: LINETYPES: END CAP SHUTOFF VALVE (BALL TYPE) TEE TURNING UP/DOWN PIPE TURNING UP/DOWN CHECK VALVE BALANCING VALVE PIPE SYMBOLS: WALL HYDRANT RO REVERSE OSMOSIS WATER SUPPLY (RO) *NOT ALL SYMBOLS OR LINETYPES ARE NECESSARILY USED*PLUMBING SYMBOLS LEGEND GREASE INTERCEPTOR SCHEDULE SYMBOL MANUF. MODEL FLOW RATE (GPM) GREASE CAPACITY (LBS.) LIQUID CAPACITY (GAL.)NOTES (#) GI SCHIER GB-250 100 1,895 277 (1), (2), (3) NOTES: 1. CONTRACTOR SHALL SUBMIT PROPOSED GREASE INTERCEPTOR INSTALLATION PLANS AND SPECIFICATIONS TO LOCAL AUTHORITIES FOR THEIR APPROVAL BEFORE ACQUISITION. SEE MANUFACTURER INSTALLATION MANUAL FOR ADDITIONAL INSTRUCTIONS. 2.PROVIDE WITH C24HP H20 LOAD RATED PICKABLE CAST IRON LIDS WITH "SAFE MANWAY" FALL PROTECTION COVER. 3. PROVIDE WITH AK1 ANCHOR KIT. PLUMBING FIXTURE SCHEDULE SYMBOL FIXTURE TYPE MANUF.MODEL DESCRIPTION ACCESSORIES/OPTIONS NOTES (#) WC WATER CLOSET (ACCESSIBLE)SLOAN ST-2029 (2102029) FLOOR MOUNT, WHITE VITREOUS CHINA, 1.1-1.6 GPF ELONGATED SIPHON JET BOWL, 1-1/2" TOP SPUD, & RIM HEIGHT 17" A.F.F. TOTO #TMT1LN32#CP 1.28 GPF MANUAL WATER CLOSET FLUSH VALVE. MAINLINE #ML1055SSC00 WHITE OPEN FRONT ELONGATED TOILET SEAT LESS COVER. (1), (4) LAV-1 LAVATORY (ACCESSIBLE) AMERICAN STANDARD #0356.421.020 LUCERNE WALL HUNG, 2012"x1814", WHITE VITREOUS CHINA.TOTO #TL210DD12#CP POLISHED CHROME, LAVATORY FAUCET, 1.2 GPM FLOW RATE (1), (2), (3), (4) LAV-2 LAVATORY (ACCESSIBLE)DURAVIT D17511 (#0454120060) VERO WALL HUNG WASHBASIN, 4714"x1812", WHITE VITREOUS CHINA,WITH CHROME METAL CONSOLE AND NO FAUCET HOLES, SINGLE HOLE FOR FAUCET, & BACK OVERFLOW. ROHL A1423LMAPC-2 "ACQUI WALL MOUNT BRIDGE FAUCET", POLISHED CHROME, 8" WALL MOUNT, 10" SWIVEL SPOUT, 1.2 GPM AERATOR. PROVIDE WITH CROW WORKS 27" HIGH GUNMETAL SINK STAND (1), (2), (4), (5) WB COMBI OVEN WATER BOX SIOUX CHIEF 696-G2403WF WHITE ABS WATER SUPPLY BOX WITH 3/4" HOSE THREAD, AND PEX-A F1960 CONENCTIONS.INSTALL PER "COMBI OVEN SUPPLY BOX ROUGH-IN" DETIAL. FPWH FROST PROOF WALL HYDRANT WOODFORD MODEL 65 ANTI-SIPHON, AUTOMATIC DRAINING, WALL HYDRANT, NON-FREEZE INTEGRAL VACUUM BREAKER, ALL BRONZE INTERIOR PARTS, KEY OPERATED, 3/4" SOLDER INLET. MOUNT 18" ABOVE FINISHED GRADE. PROVIDE APPROPRIATE MODEL FOR WALL THICKNESS AND SITE SPECIFIC TEMPERATURE REQUIREMENTS. (4) FD FLOOR DRAIN SIOUX CHIEF / ZURN 832-35D-NR / #ZN415-B-3NH FLOOR DRAIN WITH 5" ROUND NICKEL BRONZE ADJUSTABLE STRAINER AND CAST IRON BODY & 3" BOTTOM OUTLET. PROVIDE WITH ASSE 1072 APPROVED TRAP SEAL DEVICE. TRAP SEAL DEVICE SHALL BE TRAP PROSET TRAPGUARD OR APPROVED EQUAL. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE DRAINS IN CUSTOMER AREAS WITH VANDAL RESISTANT SCREWS. (4) FS-1 FLOOR SINK SIOUX CHIEF / ZURN #861-3PN-D / #Z1900-3NH-K-4 12" SQUARE TOP FLOOR SINK W/8" DEEP PVC/CAST IRON BODY & 3" BOTTOM OUTLET (CAST IRON OPTIONAL)(4) FS-2 FLOOR SINK SIOUX CHIEF / ZURN #861-23X-N2 / #Z1900-3NH-2NB 12" SQUARE TOP FLOOR SINK WITH 6" DEEP ACID RESISTANT ENAMEL CAST IRON BODY AND 3"OUTLET WITH 12 NICKEL BRONZE GRATE. SET FLOOR SINK LEVEL WITH FINISH FLOOR.(4) HD HUB DRAIN N/A N/A STUB 3" WASTE LINE 12" ABOVE FINISHED FLOOR SLAB FOR FUTURE CONNECTIONS BY OTHERS. PROVIDE WITH ASSE 1072 APPROVED TRAP SEAL DEVICE. TRAP SEAL DEVICE SHALL BE TRAP PROSET TRAPGUARD OR APPROVED EQUAL. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. (4) MV MIXING VALVE ZURN ZW3870XLT / ZW1070XL THERMOSTATIC CONTROLLER WITH INTEGRAL CHECKS, ALL BRASS BODY WITH DUAL STAINLESS STEEL STRAINER, VANDAL RESISTANT TEMPERATURE ADJUSTMENT HANDLE. SET TO 105°F. MOUNT IN ACCESSIBLE LOCATION.(4) NOTES: 1.INSTALL IN ACCORDANCE TO ADA ACCESSIBILITY REQUIREMENTS. 2.PROVIDE WITH QUARTER TURN BRASS ANGLE COMPRESSION STOPS WITH LOOSE KEY HANDLES, STAINLESS BRAIDED SUPPLIES, CHROME SUPPLY AND DRAIN ESCUTCHEONS, CHROME GRID STRAINER DRAIN WITH TAILPIECE, CHROME PLATED CAST BODY P-TRAP WITH CLEANOUT. INSULATE WASTE AND WATER PIPING WITH TRUEBRO "LAV-GUARD2" #101-EZ. 3. FURNISH WITH ZURN #Z-1231-81 LAVATORY CARRIER. 4.REFER TO ARCHITECTURAL SUPPLIER PAGE FOR WENDY'S NATIONAL VENDOR PRICING CONTACTS. VERIFY PRIOR TO BID IF GENERAL CONTRACTOR OR OWNER WILL PROVIDE EQUIPMENT. PLUMBING SCHEDULE AND NOTES P1.0 AUTHOR CHECKER 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments EX T . R A M P LCA672LCE6120 V2201 SHARED\xUS2.0-P1-1 Base.dwg 1PLUMBING PLAN - SANITARY WASTE & VENT 1/4" = 1'-0" SEE SITE PLAN FOR CONTINUATION GW UTILITY 116 1 2 3 3 T2061 QP0909 A0105 T2011 T0902 T0602 T2703 T2703 E2302 ECO 4" ECO FD FCO FD 4" 4" 3" 4" 3" 2" FCO FD 2 4" 4" 4" 3" 4" FS-1 FD FD FCO 3 FD WCO 3" 4"4"3" 3" 3" 3" 3" 3" 4" 2"2" GW GW GW 4" 4" 4" 3" 3" UC O 3 4" 6 INSTALL USED OIL SYSTEM PER VENDOR INSTRUCTIONS.WC WC LAV-1 LAV-1 3 3"3" 3" 4"4"4" 3" 2"2" 2" 3" 112" 2" 2" 112" 112" 112"2" WCO WCO FS-1 FS-1 WH-18 4" QP0222 FS-1 FCO 3" GW 9 5 1" CO 1" 3" HD 4" 3" A0202 4" GI FDFD 3" K1401 J1004 43"VTR FD WC 2" 3" 2" 2" 9 3 3" 3" 4 7 MAINTAIN SEPARATION BETWEEN UCO, SANITARY LINES, VENT LINES, AND WATER LINES IN THIS WALL. MAINTAIN SEPARATION BETWEEN THE USED COOKING OIL LINE, VENT LINES, AND DOMESTIC WATER LINES. ROUTE HOSE BIBB BELOW USED COOKING OIL LINE. 3"VTR 3"3" 3 4" UCO FS-2 #CODED NOTES: 1. EXTEND SANITARY LINE TO MAIN. FIELD VERIFY EXACT LOCATION WITH LOCAL UTILITY COMPANY PRIOR TO BID. 2. PROVIDE GB-250 KITCHEN GREASE INTERCEPTOR. LOCATE CLEAR OF DRIVE-THRU LANE. REFER TO CIVIL DRAWINGS FOR FINAL LOCATION. REFER TO "GREASE INTERCEPTOR" DETAIL. 3. VENT RISER FROM UNDER FLOOR PIPING. REFER TO SANITARY ISOMETRIC FOR CONTINUATION. 4. PROVIDE SANITARY VENT THROUGH ROOF PER "VENT THRU ROOF (VTR)" DETAIL. LOCATE VENT MINIMUM OF 10'-0" AWAY FROM AIR INTAKES ON ROOF, UNLESS APPROVED BY ENGINEER PRIOR TO INSTALLATION. VTR SHALL BE EXTENDED HIGHER THAN ANY AIR INTAKES. LOCATE PER ROOF PLAN. 5. ROUTE CONDENSATE FROM FREEZER/COOLER TO FLOOR DRAIN. PROVIDE RAYCHEM GUARDIAN GM-51-IM HEAT TRACED LINE FROM INSIDE OF COOLER TO FLOOR DRAIN. (COORDINATE POWER FOR HEAT TRACE WITH ELECTRICAL PLANS.) REFER TO "COOLER/FREEZER CONDENSATE" DETAIL. 6. ROUTE USED COOKING OIL LINE BEHIND EQUIPMENT. EXTEND LINE TO USED COOKING OIL TANK AS SHOWN. REFER TO "USED OIL RECOVERY" DETAIL. 7. ROUTE USED COOKING OIL LINE MINIMUM OF 6" ABOVE CEILING FROM EQUIPMENT TO RECOVERY TANK AS SHOWN PER PLAN. SLOPE PIPING TO BACK OF BUILDING. REFER TO INSTALLATION MANUAL FOR EXACT PITCH. LINE CANNOT HAVE ANY TRAPS. USE ONLY BACK TO BACK 45 DEGREE ELBOW TO CHANGE DIRECTION. 8. PROVIDE THREADED BLACK IRON PIPE DOWN WALL. COVER UCO LINE FROM WALL ENTRY TO POINT OF CONNECTION AT TANK WITH 1" THICK FIBERGLASS PIPE INSULATION WITH ASJ. PROVIDE EXTERIOR PIPE INSULATION WITH STAINLESS STEEL PIPE COVER THAT IS BANDED AND SEALED THROUGHOUT WITH CLEAR UV RESISTANT SILICONE CAULK. PROVIDE WALL PENETRATOIN WITH STAINLESS STEEL ESCUTCHEON. DO NOT RUN PIPE THROUGH REFRIGERATED BOXES OR SERVICES SPACES. TURN INTO TANK SHED AT 89" A.F.F. STUB OUT EXTERIOR SIDE OF WALL. 9. EMERGENCY DRAIN IN RESTROOM SHALL BE INSTALLED FLUSH TO GRADE WITH NO SLOPE. COORDINATE INSTALLATION HEIGHT WITH GENERAL CONTRACTOR TO ENSURE PROPER INSTALLATION. 2-WAY GCO 2-WAY GCO VENT PIPING BELOW GRADE 5'-0" 5'-0" FD D VENT PIPING BELOW GRADE FCO 3" 1" 2" WCO LAV-2 VENT PIPING BELOW GRADE WCO QP0222 PLUMBING PLAN - SANITARY WASTE & VENT P1.1 AUTHOR CHECKER 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments 1 13 13 2 2 8 66 K1401 QP0909 T0602 A0304 A0801 A0105 T0902T2011 FCW-3 1/2" CW, 1/2" HW, AND (2) 1/2" FW DROP DOWN IN WALL AND EXTEND THRU MILLWORK TO E4003, A0608, A0105, A0202, & (2) QP0222. FIELD VERIFY ROUTING. FCW-3 FCW-4 FCW-1 FCW-2 FCW-3 FPWH FPWH E2302 5 5 T2703 1PLUMBING PLAN - DOMESTIC WATER 1/4" = 1'-0" WC LAV-1 LAV-1 WC 4 4 4 MV MV MV MV RCP T0303 T0304 WH-1 1" 112"112" 112" 112"112" 112" 12" 12" 12" 3 4" 3 4" 3 4" 1" 1" 1" 12"12" T2213 4 T1213 ET-1 2 3 1 T2061 3 4" 1" 1" 1" FW RO WB FW RO FW RO MAINTAIN SEPARATION BETWEEN UCO, SANITARY LINES, VENT LINES, AND WATER LINES IN THIS WALL. MAINTAIN SEPARATION BETWEEN THE USED COOKING OIL LINE, VENT LINES, AND DOMESTIC WATER LINES. ROUTE HOSE BIBB BELOW USED COOKING OIL LINE. BEVERAGE EQUIPMENT NOTES 1. BEVERAGE EQUIPMENT SUPPLIER TO RUN NSF 61 TUBING FOR SODA DISPENSOR(S) AND SELF SERVE ICE MAKER(S). 2. GC, OR PLUMBING CONTRACTOR, TO MAKE FINAL CONNECTIONS FOR ICE MAKER(S). 2. GC, OR PLUMBING CONTRACTOR, TO PROVIDE OETIKER CLAMPS FOR CONNECTING BEVERAGE HOSES. 3. BEVERAGE EQUIPMENT SUPPLIER TO INSTALL SODA DISPENSERS AND ANCILLARY EQUIPMENT INCLUDING RACK, WATER BOOSTER, ETC. 4. BEVERAGE EQUIPMENT SUPPLIER TO INSTALL STAINLESS STEEL CHASE COVERS FOR NSF 61 TUBING. 5. BEVERAGE EQUIPMENT SUPPLIER TO CLEAN, SEAL, AND CAP CHASE. 6. BEVERAGE EQUIPMENT SUPPLIER TO INSTALL STAINLESS STEEL CHASE COVERS FOR NSF 61 TUBING. #CODED NOTES: 1. CHEMICAL FEED UNITS AND INSTALLATION KITS SUPPLIED BY OWNER'S REPRESENTATIVE AND INSTALLED BY CONTRACTOR. FEED STATION LOCATIONS ARE TO BE VERIFIED WITH OWNER. PROVIDE BACKFLOW PROTECTION AS REQUIRED BY LOCAL CODE AND PER BACKFLOW PREVENTER SCHEDULE. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 2. PLUMBING CONTRACTOR TO PROVIDE 1/2" INSULATED COPPER LINES IN WALL WITH BALL VALVE AT CONNECTION LOCATION AND MALE THREAD ADAPTOR ABOVE CEILING FOR CONNECTION BY BEVERAGE EQUIPMENT INSTALLER TO NSF 61 TUBING LINES. 3. BEVERAGE EQUIPMENT INSTALLER TO PROVIDE 1/2" NSF 61 TUBING FILTERED COLD WATER LINE FROM WATER FILTER TO CARBONATOR. BEVERAGE EQUIPMENT INSTALLER SHALL PROVIDE REQUIRED CODE APPROVED STAINLESS STEEL BACKFLOW PREVENTOR PRIOR TO CARBONATOR EQUIPMENT. NO COPPER WATER LINES SHALL BE USED FOR CARBONATED WATER LINES AFTER THE BACKFLOW PREVENTOR. 4. PROVIDE INDIVIDUAL MIXING VALVE FOR ALL HAND SINKS AND LAVATORIES IN AN ACCESSIBLE LOCATION. 5. ROUTE PEX-A FILTERED AND REVERSE OSMOSIS WATER LINES TO SERVE THE COMBI OVEN. 6. ROUTE 1 14" COLD WATER COPPER LINE FROM ABOVE CEILING DOWN TO APPROXIMATELY 30"+/- AFF FOR THE WATER CLOSET FLUSH VALVE. SEE RISER DIAGRAMS FOR DETAILS AND ARCHITECTURAL SHEETS FOR MORE INFORMATION. COORDINATE EXACT LOCATION WITH THE MANUFACTURER'S EQUIPMENT PRIOR TO ROUGH-IN. 7. EXTEND 3 4" COLD WATER LINE TO WATER FILTRATION SYSTEM IN UTILITY AREA. PROVIDE ALL CHECK VALVES AND SHUT-OFF VALVES REQUIRED. HOOK UP AND COMMISSION WATER FILTRATION SYSTEMS, BOOSTER PUMP, AND REVERSE OSMOSIS (RO) SYSTEM PER MANUFACTURER'S RECOMMENDATIONS. VERIFY ALL RESPONSIBILITIES WITH OWNER AND PLUMBING FIXTURE SCHEDULE. REFER TO "WATER FILTRATION SYSTEM" DETAIL. 8. DROP 1" HW AND CW AND 12" HWR LINES TO WATER HEATER, EXPANSION TANK, AND RECIRCULATING PUMP. CONTRACTOR TO FURNISH AND INSTALL WATER HEATER. REFER TO "LARGE WATER HEATER", "RECIRCULATION PUMP", AND "SMALL EXPANSION TANK" DETAILS. DISCHARGE T&P RELIEF VALVE AND OVERFLOW TO DRAIN. PROVIDE VALVE AND UNION ON INLET AND OUTLET. PROVIDE BALANCING VALVES AS REQUIRED FOR RECIRCULATING SYSTEM. 9. BEVERAGE EQUIPMENT SUPPLIER TO RUN 1/2" COLD WATER NSF 61 TUBING LINE ABOVE CEILING TO DINING ROOM FOR CONNECTION TO BEVERAGE SYSTEM. PROVIDE SHUT OFF VALVES AND BACK-FLOW PREVENTERS AS REQUIRED TO MAKE FINAL CONNECTION. COORDINATE WITH OWNER'S REPRESENTATIVE. BEVERAGE BUNDLE WHICH INCLUDES SYRUP AND FILTERED WATER LINES TO RUN OVERHEAD ABOVE CEILING, EXTEND FROM FILTER SYSTEM AND THRU 6" ESCUTCHEON PLATE IN CEILING, EXTEND OVERHEAD TO DRINK UNITS THEN DOWN THRU CEILING AND THROUGH CHASE BEHIND BEVERAGE UNIT. VERIFY RESPONSIBILITIES WITH OWNER AND FIXTURE SCHEDULE. 10. EXTEND 3/4" HOT AND COLD WATER COPPER LINES DOWN FOR THE MOP SINK/FAUCET FROM MAIN. MAKE ALL FINAL CONNECTIONS. COORDINATE EXACT LOCATION PRIOR TO ROUGH-IN. MOP SINK AREA HAS 2 FAUCETS MOUNTED DIRECTLY ABOVE EACH OTHER. REFER TO CONNECTION SCHEDULE FO0R MOUNTING HEIGHTS. MOP SINK AND HUB DRAIN PROVIDED BY KITCHEN EQUIPMENT SUPPLIER, SEE ARCHITECTURAL DETAILS. COORDINATE WITH ARCHITECTURAL AND KITCHEN VENDOR DRAWINGS FOR INSTALLATION INSTRUCTIONS. 11. BEVERAGE EQUIPMENT INSTALLER SHALL PROVIDE NSF 61 TUBING LINES, FOR COLD WATER SERVING BEVERAGE EQUIPMENT. LINES ARE SHOWN ARE SHOWN FOR REFERENCE ONLY. COORDINATE WITH OWNER'S REPRESENTATIVE. 12. ROUTE 3/4" HW TO SMALL WATER HEATER SERVING WAREWASH MACHINE. REFER TO "SMALL WATER HEATER ON PLATFORM" AND "WAREWASH W/ WATER HEATER" DETAILS. 13. EXTEND COPPER PIPING DOWN IN WALL TO FREEZE-PROOF WALL HYDRANT-WOODFORD MODEL 65 OR EQUAL, MOUNT 18" ABOVE FINISHED GRADE. VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS. 14. 1 12" WATER METER AT FLOOR WITH RPZ BACKFLOW PREVENTER, PIPE DISCHARGE TO FLOOR DRAIN. EXTEND LINE TO MAIN. FIELD VERIFY EXACT LOCATION WITH WATER COMPANY. 15. PROVIDE WATER BOX FOR FILTERED AND REVERSE OSMOSIS WATER LINES SERVING THE COMBI OVEN PER THE "COMBI OVEN WATER ROUGH-IN" DETAIL. EX T . R A M P LCA672LCE6120 V2201 15 15 4 T2703 MV MV ABOVE CEILING LAV-2 4 9 9A0202 QP0222 FCW-3 FCW-1 1" 1" 1" 14 7 11 T2212 T1212 12 9QP0222 FCW-1 WH-2 12 10 PLUMBING PLAN - DOMESTIC WATER P1.2 AUTHOR CHECKER 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments EX T . R A M P LCA672LCE6120 V2201 SHARED\xUS2.0-P1-3 Base.dwg 1PLUMBING PLAN - NATURAL GAS 1/4" = 1'-0" 1 2WH-1 1 3 3 RTU-2 RTU-1 G G G G 2" 114" 1 14" 114" 112" 112" 2WH-1 #CODED NOTES: 1. GAS SERVICE AND METER SETTING SIZED PER GAS COMPANY REQUIREMENTS FOR MAX CONNECTED LOADS AS SHOWN IN "NATURAL GAS CALCULATIONS" TABLE WITH TOTAL DEVELOPED LENGTH, INCLUDING FITTINGS, VALVES, ETC. OF 100 LINEAR FEET AND A TOTAL SYSTEM PRESSURE DROP OF 0.3" W.C. WITH 14" W.C. DELIVERED AT THE METER. HOLD GAS METER AND NATURAL GAS LINES TIGHT TO BUILDING. REFER TO "GAS SERVICE" DETAIL. 2. ROUTE NATURAL GAS LINE DOWN TO WATER HEATER AS SHOWN PER PLAN. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO INSTALLATION. REFER TO "LARGE WATER HEATER" DETAIL. 3. ROUTE NATURAL GAS UP THROUGH ROOF TO TO ROOFTOP EQUIPMENT AS SHOWN PER PLAN. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO INSTALLATION. REFER TO "ROOFTOP UNIT GAS CONNECTION" DETAIL. GAS LINES ON ROOF ARE TO BE PAINTED SAFETY YELLOW. GAS LINES MUST BE ROUTED TO ALLOW FULL ACCESS TO RTU EQUIPMENT. GAS LINE BEHIND EQUIPMENT 4GAS LINE AUTO SHUT-OFF VALVE 112"112"G 5 J1004 NATURAL GAS CALCULATIONS EQUIPMENT MBH ROOFTOP EQUIPMENT: RTU-1 270 RTU-2 270 WATER HEATING WH-1 199 KITCHEN EQUIPMENT OPEN FRYER 4 WELL 300 TOTAL GAS LOAD (MBH)1039.0 PLUMBING PLAN - NATURAL GAS P1.3 AUTHOR CHECKER 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments 1PLUMBING RISER - SANITARY WASTE & VENT NTS 2PLUMBING RISER - DOMESTIC WATER NTS T0902 T2011 T2061 FCW-2 E2302 T2703 T2703 T2703 T2703 E2302 4" 3" 3" FD 4"4" 4" 4" 4" 4" 4" 4" 3" 3" 3" 4" 4" 4" 4" 4" 3" 3" 3" 3"3" 3" ECO FCO FCO FCO FCO ECO FS-2 FS-1 FS-1 FS-1 FD FD FD FD FD FD FCO 4" 3" 3" 3" 2" 2" 2" 2" 2" 2" 2" 2" FD WCO WCO WC WC LAV-1 LAV-1 4" 4" 4" 4" 4"4" 3" 2" 2" 2"2" 2" 2" 2" 2" 2" 2" 2" 112" 112" 112" 112" 112" 112" 112" 112" 112" 112" 112" 112" 3" 3" M REFER TO WATER FILTRATION SYSTEM DETAIL 114" 3 4" 3 4" T1212 T0304 3 4" HW&CW LAV-1 WC FPWH WC 114" FPWH 3 4" 3 4" 3 4"3 4" 12"12" 12"12" 12" 12" 12" 12" 12" 12" 3 4" 3 4" 12" 112" FCW-3 FCW-4 K1401 MV LAV-1 MV MV MV 3 4" MV ET-1 WH-1 QP0909 A0304 A0801 FCW-1 FCW-2 FCW-3 12" 12" 12" 12"12" 12" 3 4" 1" 12" 3 4" CW1" 1" 1" 1" 112" 112" 112" 112" 112" 112" 112" 3 4" HW 1" 1" 1" T2213 GW GW GW GW GW GW RCP FD FCO 4" GW GW 3" T06024" 3" 3" A0105 T1213 1" WB 3 4" 12" 12" 12" 12" 12" FW RO FW RO GI 3" HD A0202 QP0222 4" 4" WCO 3" FD 3" FD 3"VTR 2" 2" 3" 112"2" 3"VTR 3" 3" 3" 3"3" 112" 2- WAY FCO 2- WAY FCO 112" 112" 3" FS-1 112" LAV-2 MV 112" 2" LAV-2 WH-2 A0608 FCW-2 FCW-3 A0202 QP0222 FCW-3 FCW-1 12" 12"A0105 12" PLUMBING RISERS P2.0 AUTHOR CHECKER 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments 3'-9 1/2" 6'-10 3/4" 1'-6" 6'-0 1/2" 13'-3 1/2" 11 ' - 2 1 / 2 " 20 ' - 7 1 / 4 " 10 ' - 7 1 / 2 " 2' - 7 " 13 ' - 1 1 " 12 ' - 1 0 " 17 ' - 1 0 3 / 4 " 11 ' - 5 1 / 2 " 9' - 9 1 / 2 " 8' - 4 3 / 4 " 9' - 9 1 / 4 " 6' - 4 1 / 4 " 6' - 8 " 21'-1 1/4" 5'-11 3/4" 9'-9 1/4" 2'-2" 13'-4 1/4" 1' - 0 1 / 2 " 8' - 3 1 / 4 " 3' - 5 3 / 4 " 11 ' - 5 3 / 4 " 16'-1 1/2" 3' - 6 1 / 2 " 3' - 5 3 / 4 " 5 1 / 2 " 12 ' - 1 0 1 / 4 " 23'-2" 24'-8 1/2" 30'-1 1/2" 31'-0 1/4" 30'-1 1/2" 30'-11 3/4" 13'-8 3/4" 11'-8 3/4" 25'-9 1/2" 1' - 5 1 / 2 " 8' - 2 1 / 4 " 9' - 9 1 / 4 " 1' - 1 0 3 / 4 " 6' - 8 1 / 2 " 7'-2 3/4" 1PLUMBING PLAN - DIMENSION CALLOUT 1/4" = 1'-0" DIMENSIONS ARE FOR REFERENCE ONLY. GENERAL CONTRACTOR TO VERIFY LAYOUT WITH WENDY'S REPRESENTATIVE. 28'-5" 0" 0"0" 0" 5' - 4 1 / 2 " REFERENCE POINT OUTSIDE FACE OF SHEATHING 15 ' - 6 1 / 2 " 1'-6 3/4" 2'-9 1/2" EX T . R A M P LCA672LCE6120 V2201 15 ' - 5 " 15'-2 3/4" 8'-10 1/4" PLUMBING DIMENSION PLAN P3.0 AUTHOR CHECKER 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments BLOCKING BY GENERAL CONTRACTOR WOOD BLOCKING CONTINUOUS INSULATION THROUGH PIPE SUPPORT WATER LINE INSULATION/PIPE SUPPORT NOT TO SCALE PIPE SUPPORT (IN-WALL)15 CW G VENT/INTAKE PIPE PROVIDED BY PLUMBING CONTRACTOR. PROVIDE 3" INTAKE PIPE AND 3" EXHAUST PIPE FROM WATER HEATER TO CONCENTRIC VENT INTAKE AIR WALL TERMINATION KIT. MAKE ALL FINAL INTAKE/ EXHAUST CONNECTIONS. COORDINATE LOCATION OF WALL OPENING WITH ARCHITECT PRIOR TO ROUGH-IN. MAINTAIN 10' CLEARANCE FROM ALL OUTSIDE AIR INTAKES. INSTALL PER MANUFACTURER'S RECOMMENDATION. CHECK VALVE 1" A.S.M.E. APPROVED TEMPERATURE AND PRESSURE RELIEF VALVE SIZE GAS PER PLAN EXTEND FULL SIZE TO DRAIN DRAIN VALVE 3/4" 1" 1"140° HW THERMOMETER WITH GAGE COCK (TYP.) - EQUAL TO WATTS #TB-1-1/2-1 SEE FLOOR PLAN FOR CONTINUATION VACUUM RELIEF VALVE 1" 1" TO EXPANSION TANK 3/4"TO RECIRC PUMP NOT TO SCALE LARGE WATER HEATER 12 INSTALL PIPE HIGH AS POSSIBLE, ANCHORED TO WALL OF BOX WITH SUPPORTS AT MAXIMUM SIX FOOT CENTERS. USE TYPE "M" HARD COPPER TUBE AND FITTINGS WITH LEAD-FREE SOLDER JOINTS. SLOPE HORIZONTAL PIPE AT MINIMUM TWO PERCENT. REFER TO LOCAL CODE FOR INDIRECT DRAIN REQUIREMENTS. ELECTRICAL AND PLUMBING CONTRACTORS TO COORDINATE WORK. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL HEAT TRACING. FLOOR 1"DX COIL CO CO NO INSULATION ON PIPE RISER SEE FLOOR PLAN FOR RECEPTACLE LOCATION. WALK-IN COOLER OR FREEZER BOX PROVIDE TRAP AT BOTTOM OF RISER AND DISCHARGE INTO FLOOR DRAIN OR FLOOR SINK WITH AIR GAP OF TWO PIPE DIAMETERS SILICONE SEAL AROUND PIPE PENETRATION PROVIDE 1" ELASTOMERIC INSULATION OVER FREEZE PROTECTION ON CONDENSATE LINE - IF/WHEN FREEZER BOX ONLY - (PROVIDE ELECTRIC HEAT TRACE CABLE PER PLAN. COORDINATE POWER REQUIREMENTS) PROVIDE CLEANOUT IN TURNS AND ENDS OF PIPE MAKE CONNECTION TO COIL AS REQUIRED NOT TO SCALE COOLER/FREEZER CONDENSATE 8 PROVIDE FIBERGLASS INSULATION WITH ALL-SERVICE JACKET WITH VAPOR BARRIER ON ALL COLD/HOT WATER PIPING AND CONDENSATE DRAIN PIPE. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION REGARDING INSULATION. INSTALL ALL ITEMS PER SPECIFICATIONS AND MANUFACTURERS INSTRUCTIONS. MAINTAIN VAPOR BARRIER ON COLD PIPING BY MEANS OF SEALANT AND TAPE. FLAME-SPREAD AND SMOKE-DEVELOPED INDEXES SHALL NOT EXCEED 25/50. SEAL EXPOSED ENDS OF FIBERGLASS INSULATION WITH ADHESIVE MASTIC. REFER TO OTHER DETAILS FOR TREATMENT OF INSULATION AT PENETRATION OF WALLS AND FIREWALLS PROVIDE INSULATION ON DOMESTIC HOT/COLD WATER PIPES, STORM WATER PIPES, AND CONDENSATE DRAIN PIPING IN WALLS AND CHASES MITER THE INSULATION AT TEES AND ELBOWS SO THAT THERE ARE NO GAPS AT JOINTS. PROVIDE ONE-PIECE PRE-MOULDED PVC FITTING COVERS PROVIDE A ONE FOOT LENGTH OF NON-COMPRESSIBLE INSULATION AT HANGERS FOR ALL PIPE 2" AND LARGER COVER VALVE BODIES WITH INSULATION, BUT NOT UNIONS TAPE JOINTS OF FIBERGLASS INSULATION FLOOR NOT TO SCALE PIPE INSULATION 4 AI R G A P 2" M I N . FINISHED FLOOR PVC PIPE (SIZE WILL VARY) 3" SANITARY LINE (SEE PLUMBING PLAN) FLOOR SINK (BY PLUMBING CONTRACTOR) NOT TO SCALE INDIRECT DRAIN 19 PROVIDE ONE PIECE SPUN ALUMINUM BASE WITH, GRADUATED STEPPED PVC BOOT, AND ADJUSTABLE STAINLESS STEEL CLAMPS. SET BASE IN BED OF MASTIC MINIMUM 12" BELOW ROOF ROOF INSULATION ROOF DECK REFER TO ARCHITECT'S DRAWING FOR APPLICATION OF VENT PIPE BOOT INSTALLATION WITH ROOFING MATERIAL PROVIDE SLEEVE IF REQUIRED BY TYPE OF ROOF DECK PROVIDE PIPE INCREASER WHERE REQUIRED TO MAKE MINIMUM 3" VENT THRU ROOF ANCHOR PIPE TO ROOF DECK OR JOISTS WITH U-BOLT AROUND PIPE AND ANGLE IRON WELDED OR SCREWED TO DECK OR JOIST HUBLESS PIPE CONNECTORS ON CAST IRON PIPE REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR A MINIMUM OF 10 FEET HORIZONTAL (UNLESS APPROVED BY ENGINEER PRIOR TO INSTALLATION) OR THREE FEET VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, AND ONE FOOT FROM ANY VERTICAL SURFACE. PROVIDE 1" FIBERGLASS INSULATION WITH ALL-SERVICE JACKET ON VENT PIPE INSIDE BUILDING WITHIN SIX FEET OF VENT THRU ROOF LOCATION. VERIFY FLASHING AND COUNTERFLASHING WITH ROOFING CONTRACTOR. TERMINATE VENT FLUSH WITH TOP OF PARAPET WALL. NOT TO SCALE VENT THRU ROOF (VTR)18 BALL VALVE: BRONZE BODY, FULL PORT, SCREWED ENDS (TYP) FULL SIZED REDUCED PRESSURE TYPE BACKFLOW PREVENTION DEVICE STRAINER: BRONZE BODY, STAINLESS SCREEN. 24 " M I N . 3" MIN. 6" MIN. PRV SET AT 75PSI SLEEVE AND CAULK CITY WATER METER DETAIL SHOWS GENERAL SCHEMATIC REQUIREMENTS. PROVIDE BACKFLOW PREVENTER OF TYPE AND MANUFACTURER APPROVED BY LOCAL AUTHORITIES. PROVIDE PRESSURE REDUCING VALVE ONLY IF PRESSURE EXCEEDS 80 PSI - VERIFY. STRAINER AND REDUCING VALVE MAY BE INSTALLED IN VERTICAL PIPE IF SPACE LIMITATIONS REQUIRE IT. CLEAN STRAINER BEFORE TURNING BUILDING OVER TO OWNER. PROVIDE ANY REQUIRED CERTIFICATION OF TEST OF BACKFLOW PREVENTER TO LOCAL AUTHORITIES. FLOOR TO FIXTURES NOT TO SCALE DOMESTIC WATER SERVICE ENTRY 14 MOP SINK PC TO PROVIDE WATER HAMMER ARRESTERS BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON AND 0-RING CONSTRUCTION, HAVING PDI #WH-201, ASSE #1010 OR ANSI #A112.26.1M CERTIFICATION. SIZE AND INSTALL PER PDI #WH-201 STANDARD OR MANUFACTURER'S INSTRUCTION. THE TABLES ABOVE ARE BASED ON THE SIOUX CHIEF PRODUCT LINE. IF PRESSURE IS IN EXCESS OF 65 PSIG THEN UPSIZE THE ARRESTER BY ONE (EXAMPLE: AN 'A' ARRESTER WOULD BECOME A 'B' ARRESTER.) UNIT LOAD FIXTUREPDI SIZE SINGLE FIXTURE KITCHEN SINKS 2.252.25 MULTIPLE FIXTURES FIXTURE UNIT TABULATION FIXTURE 3 HOT - 3 COLD 10AA A B C D 1-3 4-11 12-32 33-60 61-113 ON HORIZONTAL BRANCH LINE LESS THAN 20 FEET LONG, PLACE ONE WITHIN SIX FEET OF THE LAST FIXTURE SERVED ON BRANCH LINE GREATER THAN 20 FEET LONG, PLACE ANOTHER ARRESTER IN THE MIDDLE, EACH IS SIZED FOR HALF THE FIXTURE UNITS LAVATORY WATER CLOSET (VALVE) HW OR CW ARRESTER WITHIN SIX FEET OF FIXTURE SERVED HAND SINKS 1.51.5 WALL HYDRANT/HOSE BIB 22 1.51.5 NOT TO SCALE WATER HAMMER ARRESTORS 6 ENTER BUILDING ABOVE GRADE WITH SLEEVE. SEAL ENTRANCE INTO BUILDING WEATHER-TIGHT SIZE AS SHOWN ON PLAN - USE BLACK STEEL PIPE GAS METER - CFH CAPACITY PER PLAN SHUT-OFF VALVE GRADE OR PAVEMENT PRESSURE REGULATOR (7" W.C.) EXTERIOR BUILDING WALL BY GAS COMPANY (VERIFY) FLOOR BY PLUMBING CONTRACTOR STRAINER PRESSURE TEST COCK PIPE INCREASER VERIFY REQUIREMENTS FOR METERING AND PIPING WITH GAS COMPANY. GAS COMPANY SHALL EXCAVATE, BACKFILL, AND REPAIR PAVING AND SOD FOR GAS SERVICE LINE INSTALLATION FROM MAIN TO BUILDING. PLUMBING CONTRACTOR TO PAY ALL GAS COMPANY FEES FOR THIS INSTALLATION. USE WELDED OR SCREWED PIPE AND FITTINGS PER SPECIFICATIONS. PAINT EXPOSED METAL GAS PIPE, FITTINGS AND ITEMS TO MATCH BUILDING. 6" DEEP SEDIMENT TRAP NOT TO SCALE GAS SERVICE 2 SANITARY LINE (SEE PLUMBING PLAN) FINISH FLOOR VENT LINE (SEE PLUMBING PLAN) 3" CAPPED PVC PIPE STUBBED 1'-0" AFF NOT TO SCALE HUB DRAIN 9 PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. MAKE PIPE SAME SIZE AS TANK FITTING. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION PROCEDURE. VERIFY PROPER OPERATION WHEN INSTALLED. EXPANSION TANK INSTALLATION SHALL OCCUR ONLY WHEN THERE IS A BACKFLOW PREVENTION DEVICE INSTALLED WITHIN THE BUILDING WATER SYSTEM. WELDED STEEL THEN OPEN VALVE WATER PRESSURE, PRESSURE TO MATCH FILL TANK WITH AIR AIR CHARGING VALVE BUTYL DIAPHRAGM POLYPROPYLENE LINING EXPANSION TANK WITH DISSIMILAR METALS DIELECTRIC IF TO WATER HEATER COLD WATER SUPPLY PIPE UNION: NEXT TO PIPE TEE PIPE HANGER NOT TO SCALE SMALL EXPANSION TANK 3 TO EXPANSION TANK IF REQUIRED, SEE DETAIL STRAP-ON AQUASTAT SET 5 DEGREES LOWER THAN HEATER TEMPERATURE H.W. C.W. STRAINER RECIRCULATION PUMP CHECK VALVE WATER HEATER PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. REFER TO "LARGE WATER HEATER" DETAIL FOR MORE INFORMATION. 19RECIRCULATION PUMP NOT TO SCALE GB-250 - 100 GPM - 277 GALLON CAPACITY: DETAIL SHOWS GENERAL SCHEMATIC REQUIREMENTS. CONTRACTOR SHALL SUBMIT PROPOSED GREASE INTERCEPTOR INSTALLATION PLANS AND SPECIFICATIONS TO LOCAL AUTHORITIES FOR THEIR APPROVAL BEFORE ACQUISITION. SEE MANUFACTURER INSTALLATION MANUAL FOR ADDITIONAL INSTRUCTIONS. BED OF UNDISTURBED EARTH OR COMPACTED SAND BACKFILL: 4" - 6" 24" DIAMETER HEAVY DUTY MANHOLES 4"4" INLET DIFFUSER OUTLET DIFFUSER WATER LINE NOT TO SCALE GREASE INTERCEPTOR 15 PIPE OVER FOUR INCH CLEVIS HANGER FOR PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER EXCEPT IN CHASES. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARALLEL PIPES. HANGER SPACING FOR PIPE SIZE: COPPER: 4"=12'-0"; 3"=11'-0"; 212"=10'-0"; 2"=9'-0"; 112"=8'-0"; 114"=7'-0"; 1" & 3 4"=6'-0"; 12"=5'-0". CAST IRON: 10'-0" AND ONE NEAR ALL JOINTS. STEEL: 4"=14'-0"; 3"=12'-0"; 212"=11'-0"; 2"=10'-0"; 112"=9'-0"; 1"=7'-0"; 3 4"=6'-0"; 12"=5'-0". LOCATE HANGERS AS CLOSE AS POSSIBLE TO TURNS AND TEES OF PIPE. PROVIDE SUPPLEMENTARY STEEL STRUTS BETWEEN JOISTS IF REQUIRED. LOCATE HANGERS TO TAKE LOAD OFF OF EQUIPMENT CONNECTIONS. ANCHOR WATER PIPE AGAINST SWAYING DUE TO CHANGES IN WATER VELOCITY. PROVIDE SEISMIC BRACING IF/AS REQUIRED BY LOCAL AUTHORITIES. CHAINS OR PERFORATED STRAP IRON OR STEEL IS NOT ACCEPTABLE. REFER TO CODES FOR FURTHER INFORMATION. PROVIDE GALVANIZED STEEL SADDLE FOR ALL INSULATED PIPE LARGER THAN 3 4". VERIFY INSULATION THICKNESS WHEN SIZING HANGERS. ADJUSTABLE BAND HANGER FOR PIPING FOUR INCH OR LESS TOP BEAM C-CLAMP IF STEEL BAR JOIST STEEL DECK ALL-THREAD ROD. LENGTH AS REQ'D FOR PIPE SLOPE PROVIDE COPPER OR NON-METALLIC COATING WHERE HANGERS CONTACT BARE COPPER PIPE DO NOT HANG PIPE LARGER THAN 3" FROM BOTTOM OF JOISTS. NOT TO SCALE PIPE HANGERS 5 BA C K R O O M I C E M A K E R FI L T E R BACKFLOW PREVENTER FC W - 2 FC W - 2 CO F F E E TE A FI L T E R FI L T E R BOOSTER PUMP PRV SCALE STICK 3/4" CW PR E S S U R E G A U G E P S B FILTER LINES TO EQUIPMENT (BY OTHERS) FILTER MANIFOLD MOUNTED ON WALL NSF 61 TUBING WATER LINE PLAN OVERVIEW LAYOUT SEE DIAGRAM FOR COMPLETE DETAILS MANIFOLDS ON DRINK RACK 3/4" COLD WATER LINE F FF AUTOMATIC BY-PASS MODULE 1/2" FCW-3 1/2" FCW-4 COMBI OVEN (CLEANING CYCLE) COMBI OVEN (STEAM CYCLE) RO SYSTEM (MOUNTED AT MOP SINK) 1/ 2 " CW FC W - 1 FC W - 1 FC W - 1 FC W - 1 FR O N T R O O M I C E M A K E R (D I N I N G R O O M B E V E R A G E U N I T ) FC W - 3 FC W - 3 FC W - 3 FC W - 3 1/ 2 " F C W 1/2" 1/2" ICE MACHINE MANIFOLD BEVERAGE LINE MANIFOLD EQUIPMENT MANIFOLD NSF 61 TUBING NSF 61 TUBING BE V E R A G E L I N E (D R I V E - T H R U ) BE V E R A G E L I N E (D I N I N G R O O M ) CA R B O N A T O R (U T I L I T Y A R E A ) FILTER LINES TO EQUIPMENT (BY OTHERS) FILTER LINES TO EQUIPMENT (BY OTHERS) SP A R E 24 " A F F . OI L FRYERS CAP 24" UNION WALL PENETRATION 3/4" USED OIL RECOVERY LINE MOUNTED TO WALL WITH STANDOFF ANCHORS, ALL THREAD, AND SPLIT RING HANGERS. COORDINATE WITH ARCHITECTURAL AND VENDOR DRAWINGS FOR INSTALLATION. USED COOKING OIL LINE CANNOT PROTRUDE MORE THAN 3" FROM THE WALL. PITCH DOWN 1/4" PER FOOT TO USED COOKING OIL TANK 3" MAX.OIL PROVIDE STAINLESS STEEL ESCUTCHEON AT WALL 7USED OIL RECOVERY LINE NOT TO SCALE NOT TO SCALE WATER FILTRATION SYSTEM 1 HOT WATER TO WAREWASH AS SHOWN ON PLANS REFER TO SPECIFICATIONS AND SCHEDULE SET WATER HEATER ON PLATFORM (BY OTHERS). PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. REFER TO FLOOR PLAN FOR PIPE SIZES. SET WATER HEATER THERMOSTAT AT 140° FAHRENHEIT. PROVIDE SEISMIC STRAP OR BRACING AND FLEXIBLE CONNECTORS TO WATER AND GAS CONNECTIONS IF/AS REQUIRED BY LOCAL AUTHORITIES. SHUT-OFF VALVE PIPE UNIONS, (DIELECTRIC REQUIRED FOR DISSIMILAR METALS) VALVE DRAIN PROVIDE A 210° F TEMPERATURE AND 150 PSI PRESSURE RELIEF VALVE WITH TEST LEVER SIZED WITH AGA TEMPERATURE RATING 10% OVER HEATING INPUT HARD COPPER RELIEF DISCHARGE LINE. FULL SIZE OF VALVE OUTLET TO END OVER FLOOR SINK WITH 6 INCH AIR GAP 140° FC HOT WATER SUPPLY TO WATER HEATER NOT TO SCALE SMALL WATER HEATER ON PLATFORM 10 GAS 36 " A F F . GA S 1" FRYERS 1-1/2" 1" NPT TO FRYER 1-1/2" GAS LINE. EXTEND THROUGH WALL TO AUTOMATIC GAS SHUTOFF VALVE BELOW FINISHED CEILING WALL PENETRATIONS 3" MAX. QUICK DISCONNECT (TYP.) 1-1/2" GAS LINE MOUNTED TO WALL WITH STANDOFF ANCHORS, ALL THREAD, AND SPLIT RING HANGERS. COORDINATE WITH ARCHITECTURAL AND VENDOR DRAWINGS FOR INSTALLATION. LINE TO EXTEND COMPLETELY THROUGH WALL AND UP TO VALVE LOCATED BELOW CEILING. GAS LINE CANNOT PROTRUDE MORE THAN 3" FROM THE WALL. 3" DEEP SEDIMENT TRAP 11NATURAL GAS COOKING LINE NOT TO SCALE FR O N T R O O M I C E M A K E R (D I N I N G R O O M B E V E R A G E U N I T ) BE V E R A G E L I N E (D I N I N G R O O M ) PLUMBING DETAILS P4.0 AUTHOR CHECKER 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments ANCHOR TANK LEGS TO FLOOR OR PLATFORM OR AS REQUIRED BY LOCAL CODE AUTHORITIES. SET TANK AS CLOSE TO WALL AS POSSIBLE. PROVIDE WOOD BLOCKS FOR SPACERS BETWEEN WALL AND TANK IF REQUIRED. ATTACH TO WALL AS REQUIRED (TYP FOR 2) PROVIDE 1"x18" STEEL BAND DOWN 1/3 FROM THE TOP, AND UP 1/3 FROM THE BOTTOM OF TANK. BEND ENDS OF STRAP AND ANCHOR SECURELY TO WALL AS REQUIRED. (TYP FOR 2) WATER HEATER OR TANK NOT TO SCALE TANK SEISMIC RESTRAINT 3 SUPPLY PIPE 4" LONG SEDIMENT TRAP G SHUT-OFF VALVE.PRESSURE REGULATOR AS REQUIRED UNION. BLACK IRON. PAINT LINES SAFETY YELLOW. ROUTE LINES TO AVOID CONFLICTS ROOF TO EQUIPMENT NOT TO SCALE ROOFTOP UNIT GAS CONNECTION 1 PIPE SIZE SPACING TRANSVERSE BRACE LONGITUDINAL BRACE BOLT SIZE ROD SIZE MAX ROD LENGTH VERTICAL BRACETR. LO. 1"-2" 20' 20' 2"X2"X18GA 2"X2"X18GA 14"3 8" 20" 2"X2"X18GA 212"-3" 40' 40' 2 12"X212"X16GA 2 12"X212"X16GA 3 8"12"25" 2"X2"X16GA 4"-5" 40' 40' 2 12"X212"X16GA 2 12"X212"X16GA 12"5 8" 31" 2"X2"X16GA 6" 40' 40' 2 12"X212"X12GA 2 12"X212"X12GA 12"3 4"37"212"X212"X16GA 8" 40' 40'212"X212"X12GA 2 12"X212"X12GA 5 8"7 8"43" 2 12"X212"X12GA 10" 20' 20' 2 12"X212"X12GA 2 12"X212"X12GA 3 4"7 8" 43" 2 12"X212"X12GA DO NOT BRACE ANY PIPES WHERE TOP OF PIPE TO BOTTOM OF UPPER ATTACHMENT IS LESS THAN 12". BRACE GAS, OIL AND AIR PIPES 1" AND LARGER. BRACE ALL PIPES IN EQUIPMENT ROOMS 1-1/4" AND LARGER. BRACE ALL OTHER PIPE 2-1/2" AND LARGER. BRACE HUBLESS CAST IRON PIPE ON EACH SIDE OF ANY CHANGE IN DIRECTION OF 90 DEGREES OR MORE. MAXIMUM HANGER ROD LENGTH IS 6 FEET. WHERE LENGTH OF RUN EXCEEDS LONGITUDINAL BRACE SPACING, PROVIDE 2 FEET OFFSET IN PIPE AND LOCATE BRACE AT MID RUNS. REFER TO CURRENT EDITION OF SMACNA "SEISMIC RESTRAINT MANUAL" FOR ALTERNATIVE ATTACHMENTS AND ADDITIONAL INFORMATION AND REQUIREMENTS. (THIS DETAIL APPLIES IN THE ABSENCE OF OTHER LOCAL CODE REQUIREMENTS.) STANDARD STEEL PIPE CLAMP TRANSVERSE BRACE 4" MAXIMUM TYPICAL ALL BRACES 2 MAX. 1 MIN. 1 LONGITUDINAL BRACE 1 MIN. 2 MAX. WELD 1/8" 1"-24" STEEL BEAM CONCRETE 1 WOOD BEAM PROVIDE ROD SIZE TABULATED, WITH VERTICAL BRACE IF ROD LENGTH EXCEEDS TABULATION. ANGLE IRON BRACE AND BOLTS PER TABLE (TYP.) STEEL JOIST PIPE HANGER DRILLED IN THREADED INSERT. DO NOT USE SHOT-IN INSERTS. BOLT (WITH TWO WASHERS) BETWEEN JOIST MEMBERS BOLT (WITH TWO WASHERS) NEAR TOP OF BEAM BOLT (WITH TWO WASHERS) NEAR TOP OF BEAM UPC ZONE 3 OR 4; SMACNA SHL-A NOT TO SCALE SEISMIC BRACING FOR PIPE 4 7' - 1 1 " 12" NSF 61 TUBING CARBONATOR RACK NOT TO SCALE CARBONATOR RACK ROUGH-IN 7 3" MAX. 2' - 0 " 3' - 0 " 1' - 0 " WHEEL CHOCK (BY OTHERS) GAS MANIFOLD USED COOKING OIL LINE RESTRAINING CABLE (BY OTHERS) REFER TO HOOD DRAWINGS 9GAS FRYER INSTALLATION NOT TO SCALE 2' - 6 " 2'-6" WB WATER BOX WITH CAPPED DRAIN OUTLET. MARK SUPPLY OUTLETS WITH R.O. AND F.W. STICKERS. 12" PEX-A FW TUBING IN WALL COMBI OVEN 12" PEX-A RO TUBING WALL NOT TO SCALE COMBI OVEN WATER ROUGH-IN 6 7' - 4 3 / 4 " T.O.F.F. CEILING 8'-10" WH-2 5' - 1 3 / 4 " T2061 3 4"HW 3 4"HW 5WAREWASH W/ WATER HEATER NOT TO SCALE PLUMBING DETAILS P4.1 AUTHOR CHECKER 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments PLUMBING SPECIFICATIONS 20500 GENERAL PROVISIONS A. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL A PLUMBING SYSTEM, COMPLETE AS INDICATED ON THE DRAWINGS, AS REQUIRED BY CODE AND AS SPECIFIED HEREIN. B. WITHOUT RESTRICTING THE GENERALITY OF THE FIRST STATEMENT, THE WORK TO BE PERFORMED UNDER THIS DIVISION SHALL INCLUDE, BUT IS NOT LIMITED TO, THE FOLLOWING: 1. PLUMBING WORK AS DESCRIBED IN SECTIONS 220500 THROUGH 224000. C. THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE NOTED, IS TO PROVIDE POWER WIRING FOR EACH ITEM OF ELECTRICAL EQUIPMENT AND MAKE FINAL CONNECTIONS TO MOTORS. D. ALL FINISH PAINTING IS TO BE PERFORMED BY THE GENERAL CONTRACTOR, EXCEPT AS NOTED ELSEWHERE. THIS CONTRACTOR SHALL RESTORE TO ORIGINAL CONDITION ANY PAINTING DEFACED BY THIS CONTRACTOR AFTER ORIGINAL PAINTING. E. ALL WORK SHALL CONFORM TO CODES, RULES, AND REGULATIONS: 1. STATE PLUMBING CODE. 2. LOCAL BUILDING CODE. 3. NATIONAL FIRE PROTECTION ASSOCIATION. 4. CERTAIN CODES AND STANDARDS AS SET UP BY VARIOUS TECHNICAL SOCIETIES SUCH AS ASME, ASHRAE, ASTM, SMACNA, ARI, AABC, OR IEEE. 5. FEDERAL OCCUPATIONAL SAFETY AND HEALTH STANDARDS. 6. LOCAL INSPECTOR'S REQUIREMENTS. 7. STATE INDUSTRIAL COMMISSION REQUIREMENTS. 8. BUILDING INSURING AGENCY REQUIREMENTS. F. ALL PERMITS REQUIRED BY LAWS, ORDINANCES AND BUILDING CODES HAVING JURISDICTION SHALL BE OBTAINED AT THE PROPER TIME BY AND AT THE EXPENSE OF THIS CONTRACTOR. G. THIS CONTRACTOR SHALL OBTAIN ALL INSPECTIONS REQUIRED BY ALL LAWS, ORDINANCES AND PUBLIC AUTHORITY HAVING JURISDICTION AND SHALL OBTAIN CERTIFICATES OF SUCH INSPECTIONS AND SUBMIT SAME TO THE ARCHITECT AND SHALL PAY ALL FEES, CHARGES, ASSESSMENTS AND OTHER EXPENSES IN CONNECTION THEREWITH. H. PIPING AND EQUIPMENT LAYOUT IS SCHEMATIC. EXACT LOCATIONS ARE DETERMINED BY STRUCTURAL AND OTHER CONDITIONS. DESIGN OF SYSTEM MAY NOT BE CHANGED. ONLY EXACT LOCATION OF PIPING MAY BE REVISED TO SUIT CONSTRUCTION CONDITIONS AND AID IN COORDINATION WITH WORK OF OTHER CONTRACTORS. I. THE MATERIALS AND EQUIPMENT INSTALLED IN THE WORK SHALL MEET THE REQUIREMENTS OF THE CONTRACT DOCUMENTS AND NO MATERIALS OR EQUIPMENT SHALL BE ORDERED UNTIL REVIEWED BY THE ENGINEER AND/ OR ARCHITECT. J. THIS CONTRACTOR SHALL SUBMIT SHOP DRAWINGS PER THE DOCUMENTS PROVIDED BY THE OWNER/ARCHITECT/CONTRACTOR. 1. EXPANSION TANK 2. DRAINS AND CLEANOUTS 3. VALVES 4. ALL PLUMBING FIXTURES, FAUCETS AND FITTINGS 5. WATER HEATER 6. PIPE INSULATION 7. GREASE INTERCEPTOR K. CATALOG DATA FOR EQUIPMENT REVIEWED BY THE ARCHITECT SHALL NOT SUPERSEDE THE ENGINEER'S CONTRACT DOCUMENTS. THE REVIEW OF THE ENGINEER SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM DRAWINGS OR SPECIFICATIONS, PROVIDING PROPER CLEARANCE FABRICATION PROCESS AND COORDINATION WITH OTHER TRADES. L. WHEN SUBMITTED FOR THE ARCHITECT'S REVIEW, SHOP DRAWINGS SHALL BEAR THE CONTRACTOR'S CERTIFICATION THAT THEY HAVE REVIEWED, CHECKED AND APPROVED THE SHOP DRAWINGS, THAT THEY ARE IN HARMONY WITH THE REQUIREMENTS OF THE PROJECT AND WITH THE PROVISIONS OF THE CONTRACT DOCUMENTS AND THAT THEY HAVE VERIFIED ALL FIELD MEASUREMENTS AND CONSTRUCTION CRITERIA, MATERIALS, CATALOG NUMBERS AND SIMILAR DATA. CONTRACTOR SHALL ALSO CERTIFY THAT THE WORK REPRESENTED BY THE SHOP DRAWINGS IS RECOMMENDED BY THE CONTRACTOR AND THE CONTRACTOR'S GUARANTEE WILL FULLY APPLY. M. ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK SHALL FIRST EXAMINE THE SITE AND ALL CONDITIONS THEREIN. ALL PROPOSALS SHALL TAKE INTO CONSIDERATION ALL SUCH CONDITIONS AS MAY AFFECT THE WORK UNDER THIS CONTRACT. THE SUBMITTING OF A BID AUTOMATICALLY IMPLIES THAT THIS EXAMINATION OF SITE HAS BEEN DONE. N. CONTRACTOR SHALL VERIFY LOCATION OF UTILITIES AND NOTE CONDITIONS WHICH WOULD AFFECT THE WORK. ALL DISCREPANCIES SHALL THEN BE REPORTED PRIOR TO THE BID AWARD. O. PROVIDE INSTRUCTION TO OWNER'S OPERATING PERSONNEL AS NECESSARY, SHOWING LOCATIONS AND PROPER OPERATION OF MAJOR ITEMS OF EQUIPMENT AND SYSTEM COMPONENTS AND REFERRING TO THE OPERATING INSTRUCTION MANUAL DESCRIBED BELOW AS A GUIDE. P. COMPILE A WRITTEN MANUAL OF OPERATING INSTRUCTIONS INCLUDING COPIES OF SHOP DRAWINGS AND A LISTING OF EQUIPMENT SUPPLIERS. ASSEMBLE IN 8-1/2" X 11" HARD BACKED INDEXED BINDER. MATERIAL SHALL BE AS FOLLOWS: 1. TITLE PAGE: TITLE OF JOB, TENANT, ADDRESS, DATE OF SUBMISSION, CONTRACTOR AND ENGINEER. 2. INDEX. 3. ST OF MAJOR EQUIPMENT USED IN PROJECT ACCOMPANIED BY CONTRACTOR PURCHASE ORDER NUMBERS AND SUPPLIERS NAMES AND ADDRESSES. 4. ONE COPY OF EACH SHOP DRAWING GROUPED BY TYPES OF EQUIPMENT, I.E., PLUMBING FIXTURES, VALVES, ETC. 5. SECTION FOR EACH SYSTEM INCLUDING: 5.1. BRIEF DESCRIPTION OF SYSTEM OPERATION WITH LOCATION OF MAJOR COMPONENTS. 5.2. LIST OF ITEMS IN SYSTEM REQUIRING PERIODIC SERVICE. Q. SUBMIT A COMPLETED COPY TITLED "PLUMBING OPERATING INSTRUCTION MANUAL" ON THE BINDING EDGE OF BINDER TO ARCHITECT FOR APPROVAL. AFTER ARCHITECT'S REVIEW AND ANY CORRECTIONS REQUIRED ARE COMPLETED, SUBMIT A COPY OF THE MANUAL, TO THE OWNER. 220502 FIRESTOPPING A. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR FIRESTOPPING AROUND ALL OPENINGS FOR PIPES, DUCTS, CONDUITS ETC., INSTALLED BY CONTRACTOR AT ALL FIRE WALLS. FIRESTOPPING SHALL BE PERFORMED BY AN INSTALLER WHO HAS BEEN TRAINED BY THE MANUFACTURER, OR MANUFACTURER'S REPRESENTATIVE, IN THE INSTALLATION PROCEDURES BASED ON PUBLISHED UL TESTED FIRE STOP SYSTEMS. B. FIRESTOPPING SHALL MEET THE REQUIREMENTS OF ASTM E-814 OR UL 1479 FIRE TESTS BY A RECOGNIZED TESTING AGENCY. FIRESTOPPING SHALL ALSO CONFORM TO THE FOLLOWING GOVERNING CODES: INTERNATIONAL BUILDING CODE, NFPA 101- LIFE SAFETY CODE & NFPA 70 - NATIONAL ELECTRIC CODE. C. PENETRATION 1. CLEAN PENETRATION HOLES OF DIRT, LOOSE MATERIALS AND FOREIGN MATTER WHICH MAY AFFECT BOND OR INSTALLATION. 2. REMOVE COATINGS SUCH AS PAINT, CURING COMPOUNDS, WATER REPELLENT & SEALERS AS REQUIRED. 3. INSTALL BACKING MATERIALS TO PREVENT LIQUID MATERIAL LEAKAGE. D. APPLICATION 1. PREPARE AND APPLY PENETRATION SEALING SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS. 2. EMPLOY INSTALLATION TECHNIQUES WHICH WILL ENSURE THAT FIRESTOPPING IS DEPOSITED TO FILL AND SEAL HOLES AND OPENINGS. 3. TOOL EXPOSED SURFACES OF APPLIED SEALANT TO SMOOTH FINISH. 4. PROTECT MATERIALS FROM DAMAGE ON SURFACES SUBJECTED TO TRAFFIC. E. PROVIDE INTUMESCENT SEALANTS AND COLLARS AT OPENINGS INVOLVING PLASTIC OR INSULATED PIPE SIMILAR TO THE METACAULK SERIES 880 AND 950. F. FIRESTOPPING BY DOW CORNING, 3M, HILTI OR METACAULK MAY FURNISHED AT THE CONTRACTOR'S OPTION. 220529 PIPE ANCHORS, HANGERS AND SUPPORTS A. ALL PIPING SHALL BE SEPARATELY HUNG AND SUPPORTED FROM APPROVED STRUCTURAL MEMBERS OR CONCRETE OVERHEAD STRUCTURE ONLY. NO PIPE SHALL BE HUNG FROM ROOF DECK, PIPE, DUCTS OR OTHER COMPONENTS OR EQUIPMENT OF OTHER TRADES. B. PROVIDE LISTED/APPROVED ADJUSTABLE HANGERS, INSERTS, BRACKETS, CLAMPS, SUPPLEMENTARY STEEL AND OTHER DEVICES REQUIRED FOR PROPER SUPPORT OF ALL PIPE LINES. C. HANGERS SHALL BE DESIGNED TO ALLOW FOR EXPANSION AND CONTRACTION AND TO ALLOW INSULATION (WHERE APPLICABLE) TO RUN CONTINUOUSLY THROUGH HANGERS. D. WIRE OR STRAP HANGERS ARE NOT PERMITTED. ADJUST HANGERS SO AS TO DISTRIBUTE WEIGHT LOAD EQUALLY ON ATTACHMENTS. 220548 PLUMBING SYSTEM TESTING A. SYSTEM TESTING SHALL PROVIDE FOR THE FOLLOWING: 1. TEST NEW INTERIOR DOMESTIC WATER SYSTEM. 2. TEST ALL SOIL, WASTE, AND VENT PIPING. 3. FURNISH ALL PUMPS FOR AIR AND WATER PRESSURE TESTS ALONG WITH GAUGES AND ANY OTHER REQUIRED TEST EQUIPMENT. 4. UNDERGROUND LINES TO BE TESTED BEFORE BEING CONCEALED. CONTRACTOR SHALL REPAIR ANY LEAKS AND ALL DAMAGE RESULTING THEREFROM. 5. CHANGES IN AMBIENT TEMPERATURE WILL BE TAKEN INTO ACCOUNT WHEN TESTING UNDERGROUND PIPING, HOWEVER, THE VARIOUS SYSTEMS SHALL BE THOROUGHLY INSPECTED FOR LEAKS BEFORE HYDROSTATIC PRESSURE TESTS ARE CONCLUDED. 6. INTERIOR WATER PIPING: HYDROSTATIC TEST AT 125 PSI AWWA PROCEDURES AND TO THE SATISFACTION OF LOCAL AUTHORITY HAVING JURISDICTION. 7. SOIL, WASTE, AND VENT PIPING SHALL BE WATER AND SMOKE OR AIR TIGHT (STATE PLUMBING CODE). B. MEASURE LEAKAGE BY METERING WATER REQUIRED TO MAINTAIN LINE PRESSURE. REMOVE AIR BEFORE TESTING. C. REPAIR ANY LEAKING JOINTS AND DEMONSTRATE ACCEPTABLE LEAKAGE TO SATISFACTION OF OWNER'S REPRESENTATIVE AND APPROVING AUTHORITY. FLUSH ALL PIPING BEFORE PLACING INTO OPERATION. 220550 STERILIZATION A. STERILIZE NEW DOMESTIC WATER LINES AFTER INSTALLATION. B. FURNISH A CERTIFICATE OF STERILIZATION AND APPROVAL FOR HUMAN CONSUMPTION TO BE SIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THIS STATE, REGULARLY EMPLOYED BY THE TESTING LABORATORY. CERTIFICATE MUST BE GIVEN TO THE ARCHITECT AND OWNER BEFORE FINAL PAYMENT WILL BE MADE. C. STERILIZATION SHALL BE BY MEANS OF CHLORINE INJECTED INTO THE WATER SYSTEM NEAR THE SOURCE AND OUTLETS THROUGHOUT THE SYSTEM SHALL BE TESTED TO PROVE PRESENCE OF MINIMUM REQUIREMENTS. LEAVE CHLORINE IN FOR 24 HOURS AND FLUSH OUT SYSTEM UPON COMPLETION OF WORK. STERILIZATION PROCEDURE SHALL BE WITNESSED BY THE OWNER'S REPRESENTATIVE. D. STERILIZATION SHALL BE PERFORMED UNDER THE IMMEDIATE SUPERVISION OF A WATER TESTING LABORATORY REGULARLY ENGAGED IN THE SERVICE AND SHALL BE DONE ACCORDING TO THEIR INSTRUCTIONS. 220560 IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT A. STENCILS, LABELS, TAGS, AND COLOR CODES SHALL CONFORM TO ANSI A13. B. PRODUCTS SHALL BE SETON. EQUAL PRODUCTS BY BRADY MAY BE FURNISHED AT CONTRACTOR'S OPTION. C. STENCILS FOR EQUIPMENT SHALL BE REUSABLE AND HAVE 1" HIGH CHARACTERS. CHARACTERS SHALL BE PAINTED WHITE OVER A BLACK BACKGROUND. STENCIL ONLY AFTER FINAL PAINTING IS COMPLETE. CHARACTERS SHALL BE LEGIBLE FROM FLOOR. APPLY CLEAR ACRYLIC, LACQUER, OR VARNISH OVER THE FINISHED STENCIL. D. FOR PIPING PROVIDE ANSI STANDARD COLOR FLEXIBLE VINYL LABELS WITH PERMANENT PRESSURE SENSITIVE ADHESIVE BACK. LABEL SHALL BE OF SUFFICIENT LENGTH TO ENCIRCLE THE PIPE (AND INSULATION WHEN APPLICABLE) AND OVERLAP ON ITSELF. EACH LABEL SHALL HAVE AT LEAST ONE FLOW DIRECTION ARROW AND SHALL BE PERMANENTLY LABELED WITH PIPE CONTENT. E. SYSTEM PIPING TO LABLED SHALL INCLUDE THE FOLLOWING: 1. DOMESTIC WATER (INCLUDING COLD, HOT, RECIRCULATING, FILTERED, AND REVERSE OSMISIS) 2. SANITARY WASTE AND VENT (ABOVE GRADE ONLY) 3. NATURAL GAS 4. USED COOKING OIL F. DOMESTIC WATER PIPING SHALL BE LABLED ON EXTEROR OF INSULATION IN ACCORDANCE WITH ANSI A13. G. PIPING, VALVES, DRAINS, CONTROL PANELS AND SIMILAR EQUIPMENT SHALL BE IDENTIFIED AS TO FUNCTION AND SYSTEM NUMBER AS DIRECTED BY THE OWNER'S REPRESENTATIVE AND AS LISTED BELOW: IDENTIFICATION ITEM : TYPE PIPING : STENCIL OR PIPE LABEL VALVES : TAG PIPING SPECIALTY : TAG WATER HEATER AND OTHER EQUIPMENT : STENCIL H. IDENTIFY PIPE LINES WITH STENCIL OR PIPE LABEL WITH COLOR CODED BANDS AT THE FOLLOWING LOCATIONS: 1. AT EQUIPMENT CONNECTION AT EACH VALVE. 2. AT BOTH SIDES OF WALLS THROUGH WHICH PIPE PASSES. 3. AT EVERY 20 FT. INTERVAL ON CONTINUOUS PIPE LINES. 4. AT EACH BRANCH CONNECTION. 5. SHOW FLOW DIRECTION ARROWS AT EACH IDENTIFICATION POINT. 220700 INSULATION A. PIPE INSULATION AND APPURTENANCES AND COVERINGS ON PIPES USED IN CHASES, SHAFTS OR OTHER CONCEALED SPACES IN TYPES 1 AND 2 CONSTRUCTION SHALL HAVE A FLAME SPREAD RATING NOT EXCEEDING TWENTY-FIVE (25) AND IN TYPE 3 AND 4 CONSTRUCTION NOT EXCEEDING SEVENTY-FIVE (75) AND A SMOKE DEVELOPED RATING NOT EXCEEDING FIFTY (50). B. INSULATION SHALL BE RIDGE ONE-PIECE FIBERGLASS PIPE INSULATION WITH REQUIREMENTS COMPLYING WITH ASTM C 547, SELF-SEALING ADHESIVE LAP LONGITUDINAL JOINTS AND BUTT STRIPS FOR TRANSVERSE JOINTS. JACKETING SHALL CONFORM TO ASTM C 1136, TYPE I, MAXIMUM VAPOR TRANSMISSION RATING OF 0.02 PERM WHEN TESTED ACCORDING TO ASTM E 96, PROCEDURE A. (K VALVE) 0.25 BTU/IN./HR. * FT2 * °F AT 75°F MEAN TEMPERATURE WITH A MINIMUM R-VALVE OF R4. PROVIDE INSULATION THICKNESS AS INDICATED: DOMESTIC COLD WATER PIPING 1" AND SMALLER: 1/2" THICKNESS DOMESTIC COLD WATER PIPING 1-1/4" - 1-1/2": 3/4" THICKNESS DOMESTIC COLD WATER 2" AND LARGER: 1" THICKNESS DOMESTIC HOT WATER PIPING 3/4" AND SMALLER: 1" THICKNESS DOMESTIC HOT WATER PIPING 1" - 1-1/2: 1-1/2" THICKNESS PLUMBING VENT PIPING WITHIN 6 FEET OF ROOF OUTLET: 1" THICKNESS CONDENSATE PIPING: 1/2" THICKNESS USED COOKING OIL : 1" THICKNESS C. GLUE IN PLACE WITH SCHULLER U-GLUE. D. THE FITTINGS SHALL BE INSULATED WITH SCHULLER ZESTON INSULATION AND HAVE FACTORY PREMOLDED PVC COVERS. BUTT THE JOINTS TOGETHER AND WRAP WITH 3" WIDE STRIP TAPE, SEAL IN PLACE WITH SCHULLER U-GLUE. E. INSULATION SHALL NOT BE APPLIED UNTIL THE GENERAL CONSTRUCTION HAS PROGRESSED SUFFICIENTLY TO INSURE AGAINST PHYSICAL OR MOISTURE DAMAGE TO THE INSULATION. ALL INSULATION DAMAGED THROUGH FAILURE TO OBSERVE THIS DIRECTIVE SHALL BE REPLACED AT PLUMBING CONTRACTOR'S EXPENSE. F. INSTALL ALL INSULATION ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. G. INSULATION SHALL NOT BE APPLIED OVER FLANGES, JOINTS AND SEAMS IN PIPING. H. INSULATION SHALL BE SCHULLER. EQUAL PRODUCT BY ARMSTRONG, CERTAINTEED, OWENS-CORNING OR KNAUF MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. 221113 PLUMBING BASIC MATERIALS AND METHODS A. PROVIDE AND ERECT THE FOLLOWING PIPING AS SHOWN ON THE DRAWINGS AND/OR AS REQUIRED. 1. SANITARY BUILDING DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE. 2. SCHEDULE 40 PVC PIPING MAY BE USED FOR SANITARY WASTE AND VENT PIPING AT THE CONTRACTOR'S OPTION IF CEILING SPACE IS NOT USED AS A RETURN AIR PLENUM SPACE. 3. DOMESTIC HOT AND COLD WATER USE TYPE "L" HARD COPPER PIPE. 4. CAST IRON - NON-COMBUSTIBLE PIPING REQUIRED IN WALL AT HOODS. B. THIS CONTRACTOR IS TO BECOME INFORMED OF THE EXACT DIMENSIONS OF FINISHED WORK WHERE PIPES ARE TO BE PLACED AND WILL ARRANGE THE WORK ACCORDINGLY, ASSUMING ALL RESPONSIBILITY FOR PROPER LOCATION. IN THE ERECTION OF THE MAINS, SPECIAL CARE SHALL BE USED PROVIDING SUPPORT AND PROPER ALLOWANCES SHALL BE MADE FOR EXPANSION. C. ALL PIPE LINES MUST BE PROVIDED WITH A SUFFICIENT NUMBER OF FITTINGS OR UNIONS TO MAKE POSSIBLE DISASSEMBLY WITHOUT BREAKAGE OF FITTINGS. D. ALL EXPOSED PIPING SHALL BE NEAT AND CAREFULLY ALIGNED WITH THE STRUCTURAL ELEMENTS OF THE BUILDING. NO OFFSETS OR OBLIQUE BENDS WILL BE PERMITTED. DRAWINGS ARE DIAGRAMMATIC AND SHOULD NOT BE USED FOR LAYOUT WORK. E. ALL LOW POINTS IN WATER PIPING TO HAVE DRAIN VALVES WITH STANDARD HOSE ATTACHMENTS. HOT AND COLD WATER PIPING IS TO PITCH TOWARD THE NEAREST DRAIN VALVE. F. ALL PIPES TO BE INSTALLED SHALL BE LOCATED AT SUFFICIENT DISTANCE FROM WALLS, OTHER PIPES, CONDUIT, DUCTWORK AND OTHER OBSTACLES TO AVOID INTERFERENCE AND TO PERMIT THE APPLICATION OF FULL THICKNESS OF INSULATION SPECIFIED. G. MECHANICAL JOINT TYPE PIPING SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. THERMOMETERS BY TRERICE, ASHCROFT, MARSHALLTOWN, AND WEISS ARE ACCEPTABLE. 221000 PLUMBING SYSTEMS A. SANITARY BUILDING DRAIN, SOIL, WASTE AND VENT LINES SHALL BE SERVICE WEIGHT CAST IRON HUBLESS PIPE WITH STAINLESS STEEL AT COUPLINGS. SCHEDULE 40 PVC MAY BE USED FOR SANITARY WASTE AND VENT PIPING IF CEILING SPACE IS NOT USED AS A RETURN AIR PLENUM. TYPE NO. S1110-4 MAY BE USED IN LIEU OF FIELD FABRICATED FLASHINGS. B. VENT STACKS SHALL EXTEND THROUGH THE BUILDING, TERMINATING 12" ABOVE THE ROOF. STANDARD FLASHING SHALL BE EXTENDED 12" IN ALL DIRECTIONS FROM THE VENT TERMINAL AND TURNED DOWN INTO VENT. FLASHING UNITS AS MADE BY STONEMAN CAULK TYPE NO. S1110-4 MAY BE USED IN LIEU OF FIELD FABRICATED FLASHINGS. C. HORIZONTAL RUNS SHALL BE GIVEN AS STEEP A PITCH TOWARD THE OUTLET AS CONDITIONS WILL PERMIT BUT NOT LESS THAN 1/8" PER FOOT. D. FULL "Y" BRANCH FITTINGS AND EXTENSION WITH BRASS NIPPLES AND FINISHED SCREW PLUGS FOR CLEANOUTS SHALL BE PLACED IN ACCESSIBLE POSITIONS AT ENDS OF HORIZONTAL LINES OF PIPE AND AT FOOT OF ALL VERTICAL LINES OF PIPE OR ELSEWHERE, AS MAY BE REQUIRED BY THE CODE. E. WHERE CLEANOUTS OCCUR IN FINISHED AREAS, THEY SHALL BE RECESSED AND COVERS TO BE FLUSH WITH THE FLOOR OR WALL. F. HOT AND COLD WATER PIPING SHALL BE PROVIDED AS FOLLOWS: 1. TYPE "L" HARD COPPER TUBE WITH SOLDER FITTINGS. COPPER TUBING SHALL HAVE SWEAT JOINTS AND BE CLEAN OF SCALE AND FOREIGN MATTER BEFORE INSTALLATION. ALL ENDS OF TUBING TO BE SWEATED SHALL BE REAMED, CLEANED AND BURNISHED TO REMOVE DIRT AND OXIDE. HARD 95-5 LEAD-FREE SOLDER SHALL BE USED AND APPLIED TO THE JOINTS ACCORDING TO STANDARD PRACTICE AND/OR MANUFACTURER'S RECOMMENDATIONS. COMPRESSION STOPS AND BRAIDED SUPPLIES SHALL BE USED AT CONNECTION TO EQUIPMENT. 2. PEX-A TUBING WITH ASTM F1960 FITTINGS. PEX TUBING SHALL BE SUPPORTED WITH ADDITIONAL PEX-A PIPE CHANNEL PER MANUFACTURER'S RECOMENDATIONS. PEX PIPING SHALL BE TERMINATED AT FIXTURES WITH PREMANUFACTURERED COPPER STUBOUTS. COMPRESSION STOPS, AND BRAIDED SUPPLIES SHALL BE USED AT CONNECTION TO EQUIPMENT. PROVIDE RED TUBING FOR HOT WATER, BLUE TUBING FOR COLD WATER, AND WHITE/TRANSLUCENT TUBING FOR ALL OTHER DOMESTIC WATER. G. EACH HOT AND COLD WATER BRANCH SHALL BE PROVIDED WITH A BALL VALVE SHUT-OFF. H. GREASE INTERCEPTOR - SHALL BE AS SPECIFIED ON DRAWINGS. 221118 GAS PIPING A. ASTM A-53 SCHEDULE 40 STEEL PIPE PAINTED WITH YELLOW ANTI-CORROSIVE PAINT, SCREWED OR WELDED IN ACCORDANCE WITH CODE REQUIREMENT (FITTINGS FOR LINES LARGER THAN 2" SHALL BE WELDED STEEL. FITTINGS FOR LINES 2" AND SMALLER, EXCEPT WHEN LOCATED IN AIR PLENUMS, SHALL BE SCREWED. STANDARD WEIGHT BLACK MALLEABLE). NO VALVES ARE TO BE LOCATED IN AIR PLENUMS. B. GAS COCK'S 1-1/2" AND SMALLER SHALL BE ALL BRONZE, SCREWED, FLAT HEAD, BRASS PLUG AND WASHER 200 LB. NOG. PROVIDE LINE SIZE 6" LONG DIRT LEG DOWN STREAM OF GAS COCK AT ALL EQUIPMENT CONNECTIONS. C. PROVIDE AND INSTALL THE NATURAL GAS MANIFOLD FOR COOKING EQUIPMENT WHEN NATURAL GAS IS USED FOR FRYERS. D. ALL EQUIPMENT SHALL SHALL BE CONNECTED WITH RIGID PIPING AS SPECIFIED ABOVE, FLEXIBLE CONNECTORS ARE NOT ACCEPTABLE. E. PROVIDE UNION AT ALL EQUIPMENT CONNECTIONS. F. PROVIDE GAS PIPE SUPPORTS IN ACCORDANCE WITH CODE REQUIREMENTS. 221120 DRAIN PIPING A. FURNISH AND INSTALL A GRAVITY DRAIN PIPING SYSTEM FROM WATER HEATER, TERMINATING AT THE MOP SINK. B. PIPING IS TO BE SCHEDULE 40 PVC WITH DRAINAGE PATTERN FITTINGS, BONDED ACCORDING TO THE MANUFACTURERS RECOMMENDATIONS. C. PIPING IS TO BE SECURED TO PIPE HANGERS, USING PROPER SPACING AND THE APPROPRIATE HEIGHT TO ALLOW THE PIPE TO PITCH PROPERLY. 221140 PLUMBING PIPING SPECIALTIES - USED COOKING OIL A. ASTM A-53 SCHEDULE 40 STEEL PIPE THRESED AND SCREWED OR WELDED WITH STANDARD WEIGHT BLACK MALLEABLE FITTINGS. B. PROVIDE UNION AT ALL EQUIPMENT CONNECTIONS. C. PROVIDE PIPE SUPPORTS AND STANDOFF HANGERS IN ACCORDANCE WITH CODE REQUIREMENTS. D. EXTERIOR UCO PIPING WITH INSULATION TO THE EXTERIOR TANK REQUIRES A STAINLESS STEEL INSULATION JACKET WITH ALL JOINTS AND SEAMS SEALED WATER TIGHT USING WATERPROOF UV RESISTANT CLEAR SEALANT (3M CLEAR HYBRID 730 UV OR EQUAL RATED TO 194 DEGREE F) WITH THE ENDS COVERED TO PREVENT WATER INTRUSION AND SEAL. PROVIDE A PIPE ESCUTCHEON AT THE WALL. 223300 WATER HEATER ELECTRIC WATER HEATERS: A. PROVIDE WATER HEATER, SIZE, LOCATION AND CAPACITY AND MANUFACTURER AS INDICATED ON THE DRAWINGS. B. TANK TYPE ELECTRIC WATER HEATER WITH GLASS-LINED TANK RATED AT 150 PSI WORKING PRESSURE, MAGNESIUM ANODE PROTECTION, BRONZE DRAIN VALVE, HIGH TEMPERATURE CUT-OFF SWITCH AND IMMERSION THERMOSTAT. TANK TO HAVE A MINIMUM R-VALUE OF 10. C. FURNISH AND INSTALL A WATTS NO. 40L, 3/4" TEMPERATURE AND PRESSURE RELIEF VALVE AND EXTEND DISCHARGE PIPE, FULL SIZE, TO WITHIN 6" ABOVE THE MOP SINK OR FLOOR DRAIN. D. PROVIDE AMTROL EXPANSION TANK AS SIZED ON THE DRAWINGS. EQUAL PRODUCTS BY BELL AND GOSSETT OR ADAMSON MAY BE PROVIDED AT THE CONTRACTOR'S OPTION. FUEL FIRED WATER HEATERS A. FURNISH AND INSTALL HIGH EFFICIENCY, 96% THERMAL EFFICIENCY OR BETTER, GAS FIRED, STORAGE WATER HEATER, SIZE, LOCATION AND CAPACITY AS INDICATED ON THE DRAWINGS. B. WATER HEATER SHALL BE RHEEM RUUD WITH INTELLIGENT CONTROL SYSTEM/LCD DISPLAY. EQUAL HEATERS BY A.O. SMITH, OR LOCHINVAR MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. C. TANK TYPE GAS FIRED WATER HEATER WITH GLASS-LINED TANK RATED AT 150 PSI WORKING PRESSURE, POWERED ANODES PROTECTION, BRONZE DRAIN VALVE. TANK TO HAVE A MINIMUM R-VALUE OF 10. D. FACTORY-INSTALLED TEMPERATURE AND PRESSURE RELIEF VALVE. EXTEND DISCHARGE PIPE, FULL SIZE, TO WITHIN 6" ABOVE THE MOP SINK OR FLOOR DRAIN. E. PROVIDE WATTS, POTABLE WATER EXPANSION TANK AS SIZED ON THE DRAWINGS. EQUAL PRODUCTS BY AMTROL BELL & GOSSETT MAY BE PROVIDED AT THE CONTRACTOR'S OPTION. 224000 PLUMBING FIXTURES AND EQUIPMENT A. WATER CLOSETS AND LAVATORIES SHALL BE VITREOUS CHINA AND SHALL ALL BE BY THE SAM MANUFACTURER. B. ALL WALL HUNG LAVATORIES, FLUSH VALVES, ETC., SHALL BE PER DRAWINGS AND MOUNTED AT THE MANUFACTURER'S RECOMMENDED ROUGHING IN MEASUREMENTS, UNLESS NOTED OTHERWISE. C. VALVES TO BE AS FOLLOWS: 125 LB. S.W.P. GATE, GLOBE AND CHECK VALVES: 2. GATE (2-1/2" AND SMALLER) - ALL BRONZE, SCREWED, TAPERED, SOLID WEDGE DISC, SCREWED BONNET, RISING STEM. 3. BALL (2-1/2" AND SMALLER) - ALL BRONZE, TEFLON STEM SEALS AND SEAT, 1/4 TURN SHUT-OFF, VINYL COVERED HANDLES. 4. GLOBE (2-1/2" AND SMALLER) - ALL BRONZE, SCREWED, TAPERED, SOLID WEDGE DISC, SCREWED BONNET, RISING STEM. 5. CHECK (2-1/2" AND SMALLER) - ALL BRONZE, SCREWED, HORIZONTAL SWING CHECK WITH BRONZE DISC. C. VALVES SHALL BE MILWAUKEE. EQUAL PRODUCTS BY CRANE, HAMMOND, POWELL, WALWORTH, NORTHERN INDIANA BRASS COMPANY OR STOCKHAM MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. D. UNIONS TO BE AS FOLLOWS: 1. UNIONS FOR COPPER PIPE TO BE 150LB., ALL BRONZE, SOLDER END TYPE BY CHASE. EQUAL PRODUCTS BY CRANE, MUELLER OR NORTHERN INDIANA BRASS COMPANY MAY BE FURNISHED AT THE CONTRACTOR'S OPTION. 2. DIELECTRIC UNIONS BETWEEN FERROUS AND COPPER SHALL BE INSULATED TO PREVENT METAL-TO-METAL CONTACT AND SHALL BE MANUFACTURED BY CAPITAL MANUFACTURING COMPANY OF COLUMBUS, OHIO. EQUAL PRODUCTS BY PATROL OR PECO SALES COMPANY. E. CLEANOUTS TO BE AS FOLLOWS: 1. FLOOR TYPE TO BE ADJUSTABLE CAST IRON WITH NICKEL BRONZE TOP. TOP TO BE FLUSH WITH FLOOR. SEE DRAWINGS FOR MODEL AND MANUFACTURER. 2. WALL TYPE TO BE CAST IRON TEE WITH ROUND POLISHED STAINLESS STEEL ACCESS COVER AND THREADED PLUG. SEE DRAWINGS FOR MODEL AND MANUFACTURER. F. FLOOR DRAINS TO BE AS FOLLOWS: 1. CAST IRON BODY SHALLOW SUMP DRAIN WITH DOUBLE DRAINAGE FLANGE AND WEEPHOLES, FLASHING CLAMP, BOTTOM OUTLET WITH NEOPRENE GASKET INSIDE CONNECTOR, 6" DIAMETER ADJUSTABLE GRATE. FRAME AND GRATE TO HAVE POLISHED NICKEL-BRONZE FINISH. SEE DRAWINGS FOR MODEL AND MANUFACTURER. EQUAL PRODUCT MAY BE SUPPLIED AT THE CONTRACTOR'S OPTION. PLUMBING SPECIFICATIONS P5.0 AUTHOR CHECKER 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments 03EXPOSED BRANCH DUCT INSTALLATION DETAIL NOT TO SCALE DIFFUSER STARTER COLLAR 90° 1.5R SPIRAL ELBOW BEADED SLEEVE JOINT (TYPICAL) SPIRAL BRANCH DUCT. SUPPORT WITH GALVANIZED STEEL STRAPS ROUND BALANCING DAMPER SPIRAL SUPPLY DUCT BALANCING HANDLE. LOCK INTO POSITION AND MARK PERMANENTLY MOUNT DIFFUSER TIGHT TO BOTTOM OF 90° ELBOW 1" DIAMETER CONDENSATE DRAIN PIPE WITH SUPPORT AT MAXIMUM 2 FOOT INTERVALS. TERMINATE AT SCUPPER. STRUCTURE BELOW SLOPES DOWN AT 1/4" PER 1'-0" 5.5" THICK R-30 ROOF INSULATION ROOF SHEATHING SINGLE PLY ROOF MEMBRANE CURB MOUNTED RTU LEVELING OF CURB BY CONTRACTOR EF-2 EF-1 RTU-1 3'-0" 3' - 0 " 3' - 0 " PROVIDE 3" DEEP WATER TRAP MINIMUM. 2X6 BLOCKING DUCT DROP INSULATION STRIP PROVIDE MANUFACTURER REQUIRED CLEARANCE FROM RTU TO FAN AND A MINIMUM OF 2'-0" BETWEEN EF-1 & EF-2 APPROX. 53" ABOVE ROOF SURFACE TO FAN DISCHARGE. DISCHARGE TO BE SLIGHTLY ABOVE THE ADJACENT PARAPET. IN ALL CASES MAINTAIN 40 INCHES ABOVE ROOF TO FAN DISCHARGE MINIMUM AND AT LEAST 18 INCHES CLEAR OF COMBUSTIBLE MATERIAL. INSTALLATION OF KITCHEN EXHAUST FANS WILL PROVIDE 18 INCHES CLEAR OF FAN AND FAN BASE TO COMBUSTIBLE MATERIALS INCLUDING ROOF MEMBRANE MATERIAL ALONG THE BASE OF THE CURB. FAN DISCHARGE ELEVATION WILL BE AT LEAST 40 INCHES ABOVE THE ADJACENT ROOF. DISCHARGE WILL BE 60 INCHES CLEAR OF THE ADJACENT PARAPET IF THE FAN DISCHARGE IS BELOW THE PARAPET HEIGHT. THE DISCHARGE SHALL BE TEN FEET FROM ANY ADJACENT BUILDING. ALL EQUIPMENT SHALL BE FASTENED AND CURBS PERMANENTLY AFFIXED. FINAL INSTALLATION SHALL BE SUITABLE FOR WIND LOADS AT THE SITE. ALL REQUIREMENTS ARE TO BE REVIEWED AND APPROVED BY A LICENSED PROFESSIONAL ENGINEER. REFER TO STRUCTURAL FRAMING DETAILS AND/OR STRUCTURAL REVIEW LETTER FOR ROOF CURB STRUCTURAL FRAMING DETAILS. 08EXHAUST FAN AND RTU CURB DETAIL 1/4" = 1'-0" 6' - 6 " CO IN A SHAFT PROVIDE CLEARANCE REDUCTION METHOD WITH A 6" MINIMUM CLEARANCE.6" KITCHEN CEILING 18" 22 GAUGE METAL COMBUSTIBLE MATERIAL 1" NON COMBUSTIBLE SPACER 1" MINERAL WOOL BATT SCREW WEATHER PROTECTED OPENING. NO 90° BENDS IN GREASE DUCT ALLOWED UNLESS RADIUS ELBOWS WITH ACCESS PANELS ARE PROVIDED WITH CONSTRUCTION MANAGER APPROVAL. CONTRACTOR TO PROVIDE AIR BALANCING IN DUCTWORK FOR ALL KITCHEN EXHAUST FANS. CURB AS SUPPLIED BY FAN MANUFACTURER LISTED ACCESS OPENING ROOF REFER TO 08/M2.0 KITCHEN HOOD DUCTWORK SHALL BE 16 GAUGE CARBON STEEL OR 18 GAUGE STAINLESS STEEL. DUCTWORK SHALL BE CONTINUOUSLY EXTERNALLY WELDED LIQUID TIGHT. ALL PORTIONS OF WELDED DUCTWORK SHALL BE SLOPED BACK TO HOOD FOR DRAINAGE WITH NO TRAPS. CONTRACTOR SHALL COORDINATE AT SITE WITH TRADES TO ENSURE THIS CAN BE DONE. OPERATION OF KITCHEN HOOD SHALL BE INTERLOCKED WITH ASSOCIATED EXHAUST FAN, MOTORIZED DAMPERS, ASSOCIATED UNITS BRINGING IN MAKE UP AIR AND ANY REMOTE APPLIANCE WHERE FLUE IS DISCHARGING INTO HOOD. UPON ACTIVATION OF FIRE SUPPRESSION SYSTEM, MAKE UP AIR SYSTEM AND ALL APPLIANCES WILL SHUT DOWN AND KITCHEN EXHAUST SYSTEM WILL CONTINUE TO OPERATE. ALL GAS PIPING SHALL FOLLOW APPLICABLE GAS CODES AND BE INSTALLED BY A LICENSED CONTRACTOR FAMILIAR WITH THESE CODES. PROVIDE AUTOMATICALLY ELECTRICALLY OPERATED GAS VALVE SERVING GAS FIRED COOKING EQUIPMENT BEING SERVED BY AUTOMATIC FIRE EXTINGUISHING SYSTEM. PROVIDE INTERLOCK SO THAT COOKING EQUIPMENT WILL SHUT-DOWN ON ACTIVATION OF FIRE SUPPRESSION SYSTEM. VALVE SHALL BE LABELED, WITH INSTRUCTIONS AND LOCATED OUTSIDE OF PROTECTED AREA. AN ADDITIONAL MANUAL SHUT-OFF VALVE SHALL BE ACCESSIBLE AND BE LOCATED IMMEDIATELY UPSTREAM OF AUTOMATIC VALVE.PROVIDE MAIN GAS VALVE TO SHUT DOWN COOK LINE. LOCATE VALVE NEAR COOK LINE SO EMPLOYEE CAN MANUALLY SHUT DOWN WITHOUT HAVING TO USE LADDER, ETC. EMERGENCY PULL STATION SHALL BE ACCESSIBLY LOCATED 42" TO 48" OFF FLOOR AT POINT OF EXIT DURING A FIRE. SEE POWER PLAN FOR LOCATION. CLEARANCE AND CLEARANCE REDUCTION METHODS NFPA 96 1-3.2 CLEARANCE NOTE: HOODS, GREASE EXTRACTORS, DUCTS, ECOLOGY UNITS, FANS SHALL HAVE A CLEARANCE OF AT LEAST: 18" TO COMBUSTIBLES 3" TO LIMITED COMBUSTIBLES, 6" IN SHAFT 0" TO NON COMBUSTIBLES, 6" IN SHAFT WHERE SPACE DOES NOT ALLOW FOR NOTED CLEARANCES AS IT PERTAINS TO THE TYPE OF CONSTRUCTION, A CLEARANCE REDUCTION METHOD MAY BE APPLIED. OPTION 1 : AS ILLUSTRATED BELOW OPTION 2 : USE LISTED 3M FIRE DUCT WRAP 615+ MANUFACTURER PREFABRICATED UL APPROVED INSULATED GREASE EXHAUST DUCT IS PERMITTED IF PROVIDED BY THE HOOD SUPPLIER AS PART OF A COMPLETE HOOD AND FAN PACKAGED SYSTEM. COMPLETE ERECTION DOCUMENTS DETAILING THE REQUIRED INSTALLATION PROCEDURES SHALL BE PROVIDED FOR THE CODE OFFICIAL AND THE INSTALLING CONTRACTOR. DUCT SHALL CONFORM TO ALL NFPA 96 REQUIREMENTS AND UL LISTING. PROVIDE ACCESSIBLE CLEANOUTS AT EVERY 90 DEGREE CHANGE IN DIRECTION AND AT THE TOP OF A VERTICAL RISER UNDER ROOF. 01MECHANICAL EXHAUST DUCT DETAIL NOT TO SCALE D (2) D D D 04RADIUS ELBOW NOT TO SCALE 8" M I N . 3 PIECE PVC DURO-LAST CHILLER STACK KIT DURO-LAST CAULK DURO-LAST PREFABRICATED VENT STACK FLASHING REFRIGERATION LINESROOF DECK ALL COUNTERFLASHING DRIP SHIELD AND EXPOSED DUCTWORK SHALL BE 18 GA. GALVANIZED SHEETMETAL ALL SOLDERED AIR-TIGHT CONSTRUCTION STAINLESS STEEL BAND POSITIONED 1/4" FROM THE TOP OF THE STACK FLASHING INSULATION MEMBRANE NOT TO SCALE GOOSENECK WEATHERHOLD ROOF PENETRATION DETAIL 09 CB FE L L WHEN SHOWNTAPS TO TRUNK ONLY ECCENTRIC TRANSITION CONCENTRIC TRANSITION RECTANGULAR TO ROUND RECTANGULAR TO ROUND RECTANGULAR TO RECTANGULAR ROUND TO ROUND 45° ROUND DUCT BRANCH DUCT MAIN DUCT AIR FLOW AIR FLOW RECTANGULAR DUCT AIR FLOW 45 RECTANGULAR DUCT CONICAL FITTING. SEAL AIRTIGHT WITH MASTIC Ø-MAX.45° DIVERGING, 60° CONVERGING Ø-MAX. Ø Ø ° NOTE: USE PLAN AS GUIDE TO FITTING TYPE. A D 02DUCT FITTING DETAILS NOT TO SCALE 1-1/2" NOTE: FOR DUCT SUPPORT AND SEISMIC REQUIREMENTS, REFER TO SMACNA GUIDELINES AND LOCAL CODE REQUIREMENTS. STRAP 1/4" BOLT STRAP 05ROUND DUCT HANGER DETAIL NOT TO SCALE METAL BAND SUPPORT NYLON DRAW BAND (TYP) SUPPLY AIR DIFFUSER WITH ROUND NECK PROVIDE 1" BLANKET INSULATION COVERING AIR DEVICE BACK FLEX DUCT WITH 2" EXTERNAL INSULATION MAX. LENGTH 6'-0" T-BAR TYPE/GYP SUSPENDED CEILING RIGID ROUND INSULATED DUCT JOINT SCREWED & SEALED INSULATED SHEETMETAL SUPPLY DUCT. SEAL PER SPECIFICATIONS TIE OFF TO ROOF STRUCTURE 06CEILING DIFFUSER DETAIL NOT TO SCALE NOTES: 1. DETAIL IS FOR CONDENSATE DRAIN CONNECTIONS LOCATED ON FAN INLET SIDE ONLY. 2. SLOPE CONDENSATE DRAIN AS MUCH AS POSSIBLE TOWARD DISCHARD POINT BUT NO LESS THAN 1/4" PER FOOT. PROVIDE CLEANOUTS AT TURNS AND WHERE INDICATED. USE SCHEDULE 40 PVC PIPE AND FITTINGS WITH PRIMED AND SOLVENT WELDED JOINTS. USE DWV FITTINGS FOR SIZES 1-1/4" DIAMETER AND LARGER PIPE. SUPPORT PIPING AT FOUR FOOT INTERVALS MAXIMUM. 3. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST AS REQUIRED TO SUIT SITE CONDITION. REFER TO LOCAL CODE REQUIREMENTS FOR INDIRECT DRAIN REQUIREMENTS. 4. PROVIDE 6" HIGH PIPE VENT OPEN TO ATMOSPHERE IF REQUIRED BY LOCAL CODES. TYPICAL ROOFTOP AIR CONDITIONING UNIT CONDENSATE CONNECTION. TRAP SIZE TO BE EQUAL TO OR LARGER THAN CONNECTION SIZE BUT NO LESS THAN 3/4" PROVIDE MIRO INDUSTRIES MODEL 3-RAH ADJUSTABLE PIPE SUPPORTS & PADS, OR EQUIVALENT. PROVIDE SUPPORTS TO PREVENT PIPE SAGGING AND ALLOW FOR SLOPE. UNION CONNECTION2" 1" ROUTE TO NEAREST SCUPPER CLEANOUT TEE WITH PLUG (TYP.) DIMENSION SHALL BE EQUAL TO OR GREATER THAN FAN INLET PRESSURE IN INCHES PLUS ONE INCH THEN DIVIDED BY TWO (MINIMUM DIMENSION IS ONE INCH). DIMENSION SHALL BE EQUAL TO OR GREATER THAN FAN INLET PRESSURE IN INCHES PLUS ONE INCH (MINIMUM DIMENSION ALLOWED IS TWO INCHES). ROOF 10ROOFTOP UNIT CONDENSATE 5" = 1'-0" 22 GAUGE GALVANIZED SHEET METAL PLENUM WITH EXTERNALLY APPLIED 2" THICK EXTERNAL DUCT WRAP PERFORATED SD-2 DIFFUSER 07DUMP BOX DETAIL NOT TO SCALE CEILING INSULATED FLEXIBLE DUCT WITH BAND FASTENER ROUND SPIN-IN DUCT COLLAR 10" 24" 16"FASTEN TO DIFFUSER IN EIGHT PLACES WITH SHEETMETAL SCREWS (TWO ON EACH CORNER SIDE OF PLENUM BOX) 2" NOTES: 1. TOP INLETS TO PLENUM BOX ARE NOT ALLOWED. 2. DOVETAIL COLLARS ARE NOT ALLOWED. 3. SEAL COLLAR WITH SEAL CLASS 'A' DUCT SEALANT. 4. DO NOT CRUSH OR MODIFY DUMP BOX SIZE TO FIT OTHER MECHANICAL EQUIPMENT IN CEILING CAVITY. SUPPORT TO STUCTURE WITH SHEETMETAL STRAPS DROP FROM HVAC EQUIPMENT RECTANGULAR TRUNK DUCT ROUND TRUNK DUCT MANUAL DAMPER (TYPICAL) 45° ENTRY FITTING (TYPICAL) FLEXIBLE DUCT NOT TO SCALE ROOFTOP EQUIPMENT DUCT DROP DETAIL 11 03EXPOSED BRANCH DUCT INSTALLATION DETAIL NOT TO SCALE DIFFUSER STARTER COLLAR 90° 1.5R SPIRAL ELBOW BEADED SLEEVE JOINT (TYPICAL) SPIRAL BRANCH DUCT. SUPPORT WITH GALVANIZED STEEL STRAPS ROUND BALANCING DAMPER SPIRAL SUPPLY DUCT BALANCING HANDLE. LOCK INTO POSITION AND MARK PERMANENTLY MOUNT DIFFUSER TIGHT TO BOTTOM OF 90° ELBOW 1" DIAMETER CONDENSATE DRAIN PIPE WITH SUPPORT AT MAXIMUM 2 FOOT INTERVALS. TERMINATE AT SCUPPER. STRUCTURE BELOW SLOPES DOWN AT 1/4" PER 1'-0" 5.5" THICK R-30 ROOF INSULATION ROOF SHEATHING SINGLE PLY ROOF MEMBRANE CURB MOUNTED RTU LEVELING OF CURB BY CONTRACTOR EF-2 EF-1 RTU-1 3'-0" 3' - 0 " 3' - 0 " PROVIDE 3" DEEP WATER TRAP MINIMUM. 2X6 BLOCKING DUCT DROP INSULATION STRIP PROVIDE MANUFACTURER REQUIRED CLEARANCE FROM RTU TO FAN AND A MINIMUM OF 2'-0" BETWEEN EF-1 & EF-2 APPROX. 53" ABOVE ROOF SURFACE TO FAN DISCHARGE. DISCHARGE TO BE SLIGHTLY ABOVE THE ADJACENT PARAPET. IN ALL CASES MAINTAIN 40 INCHES ABOVE ROOF TO FAN DISCHARGE MINIMUM AND AT LEAST 18 INCHES CLEAR OF COMBUSTIBLE MATERIAL. INSTALLATION OF KITCHEN EXHAUST FANS WILL PROVIDE 18 INCHES CLEAR OF FAN AND FAN BASE TO COMBUSTIBLE MATERIALS INCLUDING ROOF MEMBRANE MATERIAL ALONG THE BASE OF THE CURB. FAN DISCHARGE ELEVATION WILL BE AT LEAST 40 INCHES ABOVE THE ADJACENT ROOF. DISCHARGE WILL BE 60 INCHES CLEAR OF THE ADJACENT PARAPET IF THE FAN DISCHARGE IS BELOW THE PARAPET HEIGHT. THE DISCHARGE SHALL BE TEN FEET FROM ANY ADJACENT BUILDING. ALL EQUIPMENT SHALL BE FASTENED AND CURBS PERMANENTLY AFFIXED. FINAL INSTALLATION SHALL BE SUITABLE FOR WIND LOADS AT THE SITE. ALL REQUIREMENTS ARE TO BE REVIEWED AND APPROVED BY A LICENSED PROFESSIONAL ENGINEER. REFER TO STRUCTURAL FRAMING DETAILS AND/OR STRUCTURAL REVIEW LETTER FOR ROOF CURB STRUCTURAL FRAMING DETAILS.6' - 6 " CO IN A SHAFT PROVIDE CLEARANCE REDUCTION METHOD WITH A 6" MINIMUM CLEARANCE.6" KITCHEN CEILING 18" 22 GAUGE METAL COMBUSTIBLE MATERIAL 1" NON COMBUSTIBLE SPACER 1" MINERAL WOOL BATT SCREW WEATHER PROTECTED OPENING. NO 90° BENDS IN GREASE DUCT ALLOWED UNLESS RADIUS ELBOWS WITH ACCESS PANELS ARE PROVIDED WITH CONSTRUCTION MANAGER APPROVAL. CONTRACTOR TO PROVIDE AIR BALANCING IN DUCTWORK FOR ALL KITCHEN EXHAUST FANS. CURB AS SUPPLIED BY FAN MANUFACTURER LISTED ACCESS OPENING ROOF REFER TO 08/M2.0 KITCHEN HOOD DUCTWORK SHALL BE 16 GAUGE CARBON STEEL OR 18 GAUGE STAINLESS STEEL. DUCTWORK SHALL BE CONTINUOUSLY EXTERNALLY WELDED LIQUID TIGHT. ALL PORTIONS OF WELDED DUCTWORK SHALL BE SLOPED BACK TO HOOD FOR DRAINAGE WITH NO TRAPS. CONTRACTOR SHALL COORDINATE AT SITE WITH TRADES TO ENSURE THIS CAN BE DONE. OPERATION OF KITCHEN HOOD SHALL BE INTERLOCKED WITH ASSOCIATED EXHAUST FAN, MOTORIZED DAMPERS, ASSOCIATED UNITS BRINGING IN MAKE UP AIR AND ANY REMOTE APPLIANCE WHERE FLUE IS DISCHARGING INTO HOOD. UPON ACTIVATION OF FIRE SUPPRESSION SYSTEM, MAKE UP AIR SYSTEM AND ALL APPLIANCES WILL SHUT DOWN AND KITCHEN EXHAUST SYSTEM WILL CONTINUE TO OPERATE. ALL GAS PIPING SHALL FOLLOW APPLICABLE GAS CODES AND BE INSTALLED BY A LICENSED CONTRACTOR FAMILIAR WITH THESE CODES. PROVIDE AUTOMATICALLY ELECTRICALLY OPERATED GAS VALVE SERVING GAS FIRED COOKING EQUIPMENT BEING SERVED BY AUTOMATIC FIRE EXTINGUISHING SYSTEM. PROVIDE INTERLOCK SO THAT COOKING EQUIPMENT WILL SHUT-DOWN ON ACTIVATION OF FIRE SUPPRESSION SYSTEM. VALVE SHALL BE LABELED, WITH INSTRUCTIONS AND LOCATED OUTSIDE OF PROTECTED AREA. AN ADDITIONAL MANUAL SHUT-OFF VALVE SHALL BE ACCESSIBLE AND BE LOCATED IMMEDIATELY UPSTREAM OF AUTOMATIC VALVE.PROVIDE MAIN GAS VALVE TO SHUT DOWN COOK LINE. LOCATE VALVE NEAR COOK LINE SO EMPLOYEE CAN MANUALLY SHUT DOWN WITHOUT HAVING TO USE LADDER, ETC. EMERGENCY PULL STATION SHALL BE ACCESSIBLY LOCATED 42" TO 48" OFF FLOOR AT POINT OF EXIT DURING A FIRE. SEE POWER PLAN FOR LOCATION. CLEARANCE AND CLEARANCE REDUCTION METHODS NFPA 96 1-3.2 CLEARANCE NOTE: HOODS, GREASE EXTRACTORS, DUCTS, ECOLOGY UNITS, FANS SHALL HAVE A CLEARANCE OF AT LEAST: 18" TO COMBUSTIBLES 3" TO LIMITED COMBUSTIBLES, 6" IN SHAFT 0" TO NON COMBUSTIBLES, 6" IN SHAFT WHERE SPACE DOES NOT ALLOW FOR NOTED CLEARANCES AS IT PERTAINS TO THE TYPE OF CONSTRUCTION, A CLEARANCE REDUCTION METHOD MAY BE APPLIED. OPTION 1 : AS ILLUSTRATED BELOW OPTION 2 : USE LISTED 3M FIRE DUCT WRAP 615+ MANUFACTURER PREFABRICATED UL APPROVED INSULATED GREASE EXHAUST DUCT IS PERMITTED IF PROVIDED BY THE HOOD SUPPLIER AS PART OF A COMPLETE HOOD AND FAN PACKAGED SYSTEM. COMPLETE ERECTION DOCUMENTS DETAILING THE REQUIRED INSTALLATION PROCEDURES SHALL BE PROVIDED FOR THE CODE OFFICIAL AND THE INSTALLING CONTRACTOR. DUCT SHALL CONFORM TO ALL NFPA 96 REQUIREMENTS AND UL LISTING. PROVIDE ACCESSIBLE CLEANOUTS AT EVERY 90 DEGREE CHANGE IN DIRECTION AND AT THE TOP OF A VERTICAL RISER UNDER ROOF. D (2) D D D 8" M I N . 3 PIECE PVC DURO-LAST CHILLER STACK KIT DURO-LAST CAULK DURO-LAST PREFABRICATED VENT STACK FLASHING REFRIGERATION LINESROOF DECK ALL COUNTERFLASHING DRIP SHIELD AND EXPOSED DUCTWORK SHALL BE 18 GA. GALVANIZED SHEETMETAL ALL SOLDERED AIR-TIGHT CONSTRUCTION STAINLESS STEEL BAND POSITIONED 1/4" FROM THE TOP OF THE STACK FLASHING INSULATION MEMBRANE CB FE L L WHEN SHOWNTAPS TO TRUNK ONLY ECCENTRIC TRANSITION CONCENTRIC TRANSITION RECTANGULAR TO ROUND RECTANGULAR TO ROUND RECTANGULAR TO RECTANGULAR ROUND TO ROUND 45° ROUND DUCT BRANCH DUCT MAIN DUCT AIR FLOW AIR FLOW RECTANGULAR DUCT AIR FLOW 45 RECTANGULAR DUCT CONICAL FITTING. SEAL AIRTIGHT WITH MASTIC Ø-MAX.45° DIVERGING, 60° CONVERGING Ø-MAX. Ø Ø ° NOTE: USE PLAN AS GUIDE TO FITTING TYPE. A D 1-1/2" NOTE: FOR DUCT SUPPORT AND SEISMIC REQUIREMENTS, REFER TO SMACNA GUIDELINES AND LOCAL CODE REQUIREMENTS. STRAP 1/4" BOLT STRAP METAL BAND SUPPORT NYLON DRAW BAND (TYP) SUPPLY AIR DIFFUSER WITH ROUND NECK PROVIDE 1" BLANKET INSULATION COVERING AIR DEVICE BACK FLEX DUCT WITH 2" EXTERNAL INSULATION MAX. LENGTH 6'-0" T-BAR TYPE/GYP SUSPENDED CEILING RIGID ROUND INSULATED DUCT JOINT SCREWED & SEALED INSULATED SHEETMETAL SUPPLY DUCT. SEAL PER SPECIFICATIONS TIE OFF TO ROOF STRUCTURE NOTES: 1. DETAIL IS FOR CONDENSATE DRAIN CONNECTIONS LOCATED ON FAN INLET SIDE ONLY. 2. SLOPE CONDENSATE DRAIN AS MUCH AS POSSIBLE TOWARD DISCHARD POINT BUT NO LESS THAN 1/4" PER FOOT. PROVIDE CLEANOUTS AT TURNS AND WHERE INDICATED. USE SCHEDULE 40 PVC PIPE AND FITTINGS WITH PRIMED AND SOLVENT WELDED JOINTS. USE DWV FITTINGS FOR SIZES 1-1/4" DIAMETER AND LARGER PIPE. SUPPORT PIPING AT FOUR FOOT INTERVALS MAXIMUM. 3. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST AS REQUIRED TO SUIT SITE CONDITION. REFER TO LOCAL CODE REQUIREMENTS FOR INDIRECT DRAIN REQUIREMENTS. 4. PROVIDE 6" HIGH PIPE VENT OPEN TO ATMOSPHERE IF REQUIRED BY LOCAL CODES. TYPICAL ROOFTOP AIR CONDITIONING UNIT CONDENSATE CONNECTION. TRAP SIZE TO BE EQUAL TO OR LARGER THAN CONNECTION SIZE BUT NO LESS THAN 3/4" PROVIDE MIRO INDUSTRIES MODEL 3-RAH ADJUSTABLE PIPE SUPPORTS & PADS, OR EQUIVALENT. PROVIDE SUPPORTS TO PREVENT PIPE SAGGING AND ALLOW FOR SLOPE. UNION CONNECTION2" 1" ROUTE TO NEAREST SCUPPER CLEANOUT TEE WITH PLUG (TYP.) DIMENSION SHALL BE EQUAL TO OR GREATER THAN FAN INLET PRESSURE IN INCHES PLUS ONE INCH THEN DIVIDED BY TWO (MINIMUM DIMENSION IS ONE INCH). DIMENSION SHALL BE EQUAL TO OR GREATER THAN FAN INLET PRESSURE IN INCHES PLUS ONE INCH (MINIMUM DIMENSION ALLOWED IS TWO INCHES). ROOF 22 GAUGE GALVANIZED SHEET METAL PLENUM WITH EXTERNALLY APPLIED 2" THICK EXTERNAL DUCT WRAP PERFORATED SD-2 DIFFUSER 07DUMP BOX DETAIL NOT TO SCALE CEILING INSULATED FLEXIBLE DUCT WITH BAND FASTENER ROUND SPIN-IN DUCT COLLAR 10" 24" 16"FASTEN TO DIFFUSER IN EIGHT PLACES WITH SHEETMETAL SCREWS (TWO ON EACH CORNER SIDE OF PLENUM BOX) 2" NOTES: 1. TOP INLETS TO PLENUM BOX ARE NOT ALLOWED. 2. DOVETAIL COLLARS ARE NOT ALLOWED. 3. SEAL COLLAR WITH SEAL CLASS 'A' DUCT SEALANT. 4. DO NOT CRUSH OR MODIFY DUMP BOX SIZE TO FIT OTHER MECHANICAL EQUIPMENT IN CEILING CAVITY. SUPPORT TO STUCTURE WITH SHEETMETAL STRAPS DROP FROM HVAC EQUIPMENT RECTANGULAR TRUNK DUCT ROUND TRUNK DUCT MANUAL DAMPER (TYPICAL) 45° ENTRY FITTING (TYPICAL) FLEXIBLE DUCT NOT TO SCALE ROOFTOP EQUIPMENT DUCT DROP DETAIL 11 10ROOFTOP UNIT CONDENSATE 5" = 1'-0"06CEILING DIFFUSER DETAIL NOT TO SCALE 05ROUND DUCT HANGER DETAIL NOT TO SCALE 02DUCT FITTING DETAILS NOT TO SCALE NOT TO SCALE GOOSENECK WEATHERHOLD ROOF PENETRATION DETAIL 09 04RADIUS ELBOW NOT TO SCALE 01MECHANICAL EXHAUST DUCT DETAIL NOT TO SCALE08EXHAUST FAN AND RTU CURB DETAIL 1/4" = 1'-0" 03EXPOSED BRANCH DUCT INSTALLATION DETAIL NOT TO SCALE DIFFUSER STARTER COLLAR 90° 1.5R SPIRAL ELBOW BEADED SLEEVE JOINT (TYPICAL) SPIRAL BRANCH DUCT. SUPPORT WITH GALVANIZED STEEL STRAPS ROUND BALANCING DAMPER SPIRAL SUPPLY DUCT BALANCING HANDLE. LOCK INTO POSITION AND MARK PERMANENTLY MOUNT DIFFUSER TIGHT TO BOTTOM OF 90° ELBOW 1" DIAMETER CONDENSATE DRAIN PIPE WITH SUPPORT AT MAXIMUM 2 FOOT INTERVALS. TERMINATE AT SCUPPER. STRUCTURE BELOW SLOPES DOWN AT 1/4" PER 1'-0" 5.5" THICK R-30 ROOF INSULATION ROOF SHEATHING SINGLE PLY ROOF MEMBRANE CURB MOUNTED RTU LEVELING OF CURB BY CONTRACTOR EF-2 EF-1 RTU-1 3'-0" 3' - 0 " 3' - 0 " PROVIDE 3" DEEP WATER TRAP MINIMUM. 2X6 BLOCKING DUCT DROP INSULATION STRIP PROVIDE MANUFACTURER REQUIRED CLEARANCE FROM RTU TO FAN AND A MINIMUM OF 2'-0" BETWEEN EF-1 & EF-2 APPROX. 53" ABOVE ROOF SURFACE TO FAN DISCHARGE. DISCHARGE TO BE SLIGHTLY ABOVE THE ADJACENT PARAPET. IN ALL CASES MAINTAIN 40 INCHES ABOVE ROOF TO FAN DISCHARGE MINIMUM AND AT LEAST 18 INCHES CLEAR OF COMBUSTIBLE MATERIAL. INSTALLATION OF KITCHEN EXHAUST FANS WILL PROVIDE 18 INCHES CLEAR OF FAN AND FAN BASE TO COMBUSTIBLE MATERIALS INCLUDING ROOF MEMBRANE MATERIAL ALONG THE BASE OF THE CURB. FAN DISCHARGE ELEVATION WILL BE AT LEAST 40 INCHES ABOVE THE ADJACENT ROOF. DISCHARGE WILL BE 60 INCHES CLEAR OF THE ADJACENT PARAPET IF THE FAN DISCHARGE IS BELOW THE PARAPET HEIGHT. THE DISCHARGE SHALL BE TEN FEET FROM ANY ADJACENT BUILDING. ALL EQUIPMENT SHALL BE FASTENED AND CURBS PERMANENTLY AFFIXED. FINAL INSTALLATION SHALL BE SUITABLE FOR WIND LOADS AT THE SITE. ALL REQUIREMENTS ARE TO BE REVIEWED AND APPROVED BY A LICENSED PROFESSIONAL ENGINEER. REFER TO STRUCTURAL FRAMING DETAILS AND/OR STRUCTURAL REVIEW LETTER FOR ROOF CURB STRUCTURAL FRAMING DETAILS.6' - 6 " CO IN A SHAFT PROVIDE CLEARANCE REDUCTION METHOD WITH A 6" MINIMUM CLEARANCE.6" KITCHEN CEILING 18" 22 GAUGE METAL COMBUSTIBLE MATERIAL 1" NON COMBUSTIBLE SPACER 1" MINERAL WOOL BATT SCREW WEATHER PROTECTED OPENING. NO 90° BENDS IN GREASE DUCT ALLOWED UNLESS RADIUS ELBOWS WITH ACCESS PANELS ARE PROVIDED WITH CONSTRUCTION MANAGER APPROVAL. CONTRACTOR TO PROVIDE AIR BALANCING IN DUCTWORK FOR ALL KITCHEN EXHAUST FANS. CURB AS SUPPLIED BY FAN MANUFACTURER LISTED ACCESS OPENING ROOF REFER TO 08/M2.0 KITCHEN HOOD DUCTWORK SHALL BE 16 GAUGE CARBON STEEL OR 18 GAUGE STAINLESS STEEL. DUCTWORK SHALL BE CONTINUOUSLY EXTERNALLY WELDED LIQUID TIGHT. ALL PORTIONS OF WELDED DUCTWORK SHALL BE SLOPED BACK TO HOOD FOR DRAINAGE WITH NO TRAPS. CONTRACTOR SHALL COORDINATE AT SITE WITH TRADES TO ENSURE THIS CAN BE DONE. OPERATION OF KITCHEN HOOD SHALL BE INTERLOCKED WITH ASSOCIATED EXHAUST FAN, MOTORIZED DAMPERS, ASSOCIATED UNITS BRINGING IN MAKE UP AIR AND ANY REMOTE APPLIANCE WHERE FLUE IS DISCHARGING INTO HOOD. UPON ACTIVATION OF FIRE SUPPRESSION SYSTEM, MAKE UP AIR SYSTEM AND ALL APPLIANCES WILL SHUT DOWN AND KITCHEN EXHAUST SYSTEM WILL CONTINUE TO OPERATE. ALL GAS PIPING SHALL FOLLOW APPLICABLE GAS CODES AND BE INSTALLED BY A LICENSED CONTRACTOR FAMILIAR WITH THESE CODES. PROVIDE AUTOMATICALLY ELECTRICALLY OPERATED GAS VALVE SERVING GAS FIRED COOKING EQUIPMENT BEING SERVED BY AUTOMATIC FIRE EXTINGUISHING SYSTEM. PROVIDE INTERLOCK SO THAT COOKING EQUIPMENT WILL SHUT-DOWN ON ACTIVATION OF FIRE SUPPRESSION SYSTEM. VALVE SHALL BE LABELED, WITH INSTRUCTIONS AND LOCATED OUTSIDE OF PROTECTED AREA. AN ADDITIONAL MANUAL SHUT-OFF VALVE SHALL BE ACCESSIBLE AND BE LOCATED IMMEDIATELY UPSTREAM OF AUTOMATIC VALVE.PROVIDE MAIN GAS VALVE TO SHUT DOWN COOK LINE. LOCATE VALVE NEAR COOK LINE SO EMPLOYEE CAN MANUALLY SHUT DOWN WITHOUT HAVING TO USE LADDER, ETC. EMERGENCY PULL STATION SHALL BE ACCESSIBLY LOCATED 42" TO 48" OFF FLOOR AT POINT OF EXIT DURING A FIRE. SEE POWER PLAN FOR LOCATION. CLEARANCE AND CLEARANCE REDUCTION METHODS NFPA 96 1-3.2 CLEARANCE NOTE: HOODS, GREASE EXTRACTORS, DUCTS, ECOLOGY UNITS, FANS SHALL HAVE A CLEARANCE OF AT LEAST: 18" TO COMBUSTIBLES 3" TO LIMITED COMBUSTIBLES, 6" IN SHAFT 0" TO NON COMBUSTIBLES, 6" IN SHAFT WHERE SPACE DOES NOT ALLOW FOR NOTED CLEARANCES AS IT PERTAINS TO THE TYPE OF CONSTRUCTION, A CLEARANCE REDUCTION METHOD MAY BE APPLIED. OPTION 1 : AS ILLUSTRATED BELOW OPTION 2 : USE LISTED 3M FIRE DUCT WRAP 615+ MANUFACTURER PREFABRICATED UL APPROVED INSULATED GREASE EXHAUST DUCT IS PERMITTED IF PROVIDED BY THE HOOD SUPPLIER AS PART OF A COMPLETE HOOD AND FAN PACKAGED SYSTEM. COMPLETE ERECTION DOCUMENTS DETAILING THE REQUIRED INSTALLATION PROCEDURES SHALL BE PROVIDED FOR THE CODE OFFICIAL AND THE INSTALLING CONTRACTOR. DUCT SHALL CONFORM TO ALL NFPA 96 REQUIREMENTS AND UL LISTING. PROVIDE ACCESSIBLE CLEANOUTS AT EVERY 90 DEGREE CHANGE IN DIRECTION AND AT THE TOP OF A VERTICAL RISER UNDER ROOF. D (2) D D D 8" M I N . 3 PIECE PVC DURO-LAST CHILLER STACK KIT DURO-LAST CAULK DURO-LAST PREFABRICATED VENT STACK FLASHING REFRIGERATION LINESROOF DECK ALL COUNTERFLASHING DRIP SHIELD AND EXPOSED DUCTWORK SHALL BE 18 GA. GALVANIZED SHEETMETAL ALL SOLDERED AIR-TIGHT CONSTRUCTION STAINLESS STEEL BAND POSITIONED 1/4" FROM THE TOP OF THE STACK FLASHING INSULATION MEMBRANE CB FE L L WHEN SHOWNTAPS TO TRUNK ONLY ECCENTRIC TRANSITION CONCENTRIC TRANSITION RECTANGULAR TO ROUND RECTANGULAR TO ROUND RECTANGULAR TO RECTANGULAR ROUND TO ROUND 45° ROUND DUCT BRANCH DUCT MAIN DUCT AIR FLOW AIR FLOW RECTANGULAR DUCT AIR FLOW 45 RECTANGULAR DUCT CONICAL FITTING. SEAL AIRTIGHT WITH MASTIC Ø-MAX.45° DIVERGING, 60° CONVERGING Ø-MAX. Ø Ø ° NOTE: USE PLAN AS GUIDE TO FITTING TYPE. A D 1-1/2" NOTE: FOR DUCT SUPPORT AND SEISMIC REQUIREMENTS, REFER TO SMACNA GUIDELINES AND LOCAL CODE REQUIREMENTS. STRAP 1/4" BOLT STRAP METAL BAND SUPPORT NYLON DRAW BAND (TYP) SUPPLY AIR DIFFUSER WITH ROUND NECK PROVIDE 1" BLANKET INSULATION COVERING AIR DEVICE BACK FLEX DUCT WITH 2" EXTERNAL INSULATION MAX. LENGTH 6'-0" T-BAR TYPE/GYP SUSPENDED CEILING RIGID ROUND INSULATED DUCT JOINT SCREWED & SEALED INSULATED SHEETMETAL SUPPLY DUCT. SEAL PER SPECIFICATIONS TIE OFF TO ROOF STRUCTURE NOTES: 1. DETAIL IS FOR CONDENSATE DRAIN CONNECTIONS LOCATED ON FAN INLET SIDE ONLY. 2. SLOPE CONDENSATE DRAIN AS MUCH AS POSSIBLE TOWARD DISCHARD POINT BUT NO LESS THAN 1/4" PER FOOT. PROVIDE CLEANOUTS AT TURNS AND WHERE INDICATED. USE SCHEDULE 40 PVC PIPE AND FITTINGS WITH PRIMED AND SOLVENT WELDED JOINTS. USE DWV FITTINGS FOR SIZES 1-1/4" DIAMETER AND LARGER PIPE. SUPPORT PIPING AT FOUR FOOT INTERVALS MAXIMUM. 3. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST AS REQUIRED TO SUIT SITE CONDITION. REFER TO LOCAL CODE REQUIREMENTS FOR INDIRECT DRAIN REQUIREMENTS. 4. PROVIDE 6" HIGH PIPE VENT OPEN TO ATMOSPHERE IF REQUIRED BY LOCAL CODES. TYPICAL ROOFTOP AIR CONDITIONING UNIT CONDENSATE CONNECTION. TRAP SIZE TO BE EQUAL TO OR LARGER THAN CONNECTION SIZE BUT NO LESS THAN 3/4" PROVIDE MIRO INDUSTRIES MODEL 3-RAH ADJUSTABLE PIPE SUPPORTS & PADS, OR EQUIVALENT. PROVIDE SUPPORTS TO PREVENT PIPE SAGGING AND ALLOW FOR SLOPE. UNION CONNECTION2" 1" ROUTE TO NEAREST SCUPPER CLEANOUT TEE WITH PLUG (TYP.) DIMENSION SHALL BE EQUAL TO OR GREATER THAN FAN INLET PRESSURE IN INCHES PLUS ONE INCH THEN DIVIDED BY TWO (MINIMUM DIMENSION IS ONE INCH). DIMENSION SHALL BE EQUAL TO OR GREATER THAN FAN INLET PRESSURE IN INCHES PLUS ONE INCH (MINIMUM DIMENSION ALLOWED IS TWO INCHES). ROOF 22 GAUGE GALVANIZED SHEET METAL PLENUM WITH EXTERNALLY APPLIED 2" THICK EXTERNAL DUCT WRAP PERFORATED SD-2 DIFFUSER 07DUMP BOX DETAIL NOT TO SCALE CEILING INSULATED FLEXIBLE DUCT WITH BAND FASTENER ROUND SPIN-IN DUCT COLLAR 10" 24" 16"FASTEN TO DIFFUSER IN EIGHT PLACES WITH SHEETMETAL SCREWS (TWO ON EACH CORNER SIDE OF PLENUM BOX) 2" NOTES: 1. TOP INLETS TO PLENUM BOX ARE NOT ALLOWED. 2. DOVETAIL COLLARS ARE NOT ALLOWED. 3. SEAL COLLAR WITH SEAL CLASS 'A' DUCT SEALANT. 4. DO NOT CRUSH OR MODIFY DUMP BOX SIZE TO FIT OTHER MECHANICAL EQUIPMENT IN CEILING CAVITY. SUPPORT TO STUCTURE WITH SHEETMETAL STRAPS DROP FROM HVAC EQUIPMENT RECTANGULAR TRUNK DUCT ROUND TRUNK DUCT MANUAL DAMPER (TYPICAL) 45° ENTRY FITTING (TYPICAL) FLEXIBLE DUCT NOT TO SCALE ROOFTOP EQUIPMENT DUCT DROP DETAIL 11 10ROOFTOP UNIT CONDENSATE 5" = 1'-0"06CEILING DIFFUSER DETAIL NOT TO SCALE 05ROUND DUCT HANGER DETAIL NOT TO SCALE 02DUCT FITTING DETAILS NOT TO SCALE NOT TO SCALE GOOSENECK WEATHERHOLD ROOF PENETRATION DETAIL 09 04RADIUS ELBOW NOT TO SCALE 01MECHANICAL EXHAUST DUCT DETAIL NOT TO SCALE08EXHAUST FAN AND RTU CURB DETAIL 1/4" = 1'-0" 12 / 2 2 / 2 0 1 7 4 : 1 1 : 5 2 P M 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments HVAC DETAILS M2.0 OM DRC MECHANICAL SPECIFICATIONS 230500 COMMON WORK RESULTS FOR HVAC A. PROVIDE MATERIALS AND EQUIPMENT AND LABOR REQUIRED TO INSTALL HEATING, VENTILATING AND AIR CONDITIONING SYSTEM, COMPLETE AS INDICATED ON DRAWINGS, AS REQUIRED BY CODE AND AS SPECIFIED HEREIN. B. WITHOUT RESTRICTING THE GENERALITY OF THE FIRST STATEMENT, THE WORK TO BE PERFORMED UNDER THIS DIVISION SHALL INCLUDE, BUT IS NOT LIMITED TO, THE FOLLOWING: 1. HVAC WORK AS DESCRIBED IN SECTIONS 230500 THROUGH 233813. C. ELECTRICAL CONTRACTOR, UNLESS OTHERWISE NOTED, SHALL PROVIDE POWER WIRING FOR EACH ITEM OF ELECTRICAL EQUIPMENT AND MAKE FINAL CONNECTION TO MOTORS. D. FINISH PAINTING SHALL BE PERFORMED BY GENERAL CONTRACTOR, EXCEPT AS NOTED ELSEWHERE. CONTRACTOR SHALL RESTORE TO ORIGINAL CONDITION PAINTING DEFACED BY CONTRACTOR AFTER ORIGINAL PAINTING. E. ALL WORK SHALL CONFORM TO CODES, RULES, AND REGULATIONS: 1. NATIONAL ELECTRICAL CODE. 2. STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS, NFPA 90A. 3. CODE FOR SAFETY TO LIFE FROM FIRE IN BUILDINGS AND STRUCTURES, NFPA 101. 4. FEDERAL OCCUPATIONAL SAFETY AND HEALTH STANDARDS. 5. STATE MECHANICAL CODE. 6. STATE BUILDING CODE 7. STATE INDUSTRIAL COMMISSION REQUIREMENTS. 8. LOCAL BUILDING CODE REQUIREMENTS. 9. BUILDING INSURING AGENCY REQUIREMENTS. F. PERMITS REQUIRED BY LAWS, ORDINANCES AND BUILDING CODES HAVING JURISDICTION SHALL BE OBTAINED AT THE PROPER TIME BY AND AT EXPENSE OF CONTRACTOR. G. CONTRACTOR SHALL OBTAIN INSPECTIONS REQUIRED BY LAWS, ORDINANCES AND PUBLIC AUTHORITY HAVING JURISDICTION AND SHALL OBTAIN CERTIFICATES OF SUCH INSPECTIONS AND SUBMIT SAME TO ARCHITECT AND SHALL PAY FEES, CHARGES, ASSESSMENTS AND OTHER EXPENSES IN CONNECTION THEREWITH. H. PIPING AND EQUIPMENT LAYOUT ARE SCHEMATIC. EXACT LOCATIONS ARE DETERMINED BY STRUCTURAL AND OTHER CONDITIONS. DESIGN OF SYSTEM MAY NOT BE CHANGED. ONLY EXACT LOCATION OF PIPING AND DUCTS MAY BE REVISED TO SUIT CONSTRUCTION CONDITIONS AND AID IN COORDINATION WITH WORK OF OTHER CONTRACTORS. I. MATERIALS AND EQUIPMENT INSTALLED AS PART OF THE WORK SHALL MEET REQUIREMENTS OF THE CONTRACT DOCUMENTS AND NO MATERIALS OR EQUIPMENT SHALL BE ORDERED UNTIL REVIEWED BY OWNER. ARCHITECT OF RECORD IS RESPONSIBLE FOR REVIEWING AND APPROVING HVAC SUBMITTALS. HVAC UNITS SHALL NOT BE CONSIDERED AS ORDERED AND IN PROGRESS UNTIL SUBMITTALS ARE FORMALLY APPROVED AND RETURNED TO HVAC SUPPLIER. J. CATALOG DATA FOR EQUIPMENT REVIEWED BY OWNER SHALL NOT SUPERSEDE CONTRACT DOCUMENTS. REVIEW OF PRODUCTS SHALL NOT RELIEVE CONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM DRAWINGS OR SPECIFICATIONS, PROVIDING PROPER CLEARANCE, FABRICATION PROCESS AND COORDINATION WITH OTHER TRADES. K. WHEN SUBMITTED FOR REVIEW, SHOP DRAWINGS SHALL BEAR CONTRACTOR'S CERTIFICATION THAT CONTRACTOR HAS REVIEWED, CHECKED AND APPROVED SHOP DRAWINGS, THAT THEY ARE IN HARMONY WITH REQUIREMENTS OF THE PROJECT AND WITH THE PROVISIONS OF CONTRACT DOCUMENTS AND THAT CONTRACTOR HAS VERIFIED ALL FIELD MEASUREMENTS AND CONSTRUCTION CRITERIA, MATERIALS, CATALOG NUMBERS AND SIMILAR DATA. CONTRACTOR SHALL ALSO CERTIFY THAT WORK REPRESENTED BY THE SHOP DRAWINGS IS RECOMMENDED BY CONTRACTOR AND THE CONTRACTOR'S GUARANTEE WILL FULLY APPLY. L. CONTRACTOR SHALL VERIFY LOCATION OF UTILITIES AND NOTE CONDITIONS WHICH WOULD AFFECT THE WORK. DISCREPANCIES SHALL BE REPORTED PRIOR TO BID AWARD. M. PROVIDE INSTRUCTION TO OWNER'S OPERATING PERSONNEL AS NECESSARY, SHOWING LOCATIONS AND PROPER OPERATION OF MAJOR ITEMS OF EQUIPMENT AND SYSTEM COMPONENTS AND REFERRING TO OPERATING INSTRUCTION MANUAL DESCRIBED BELOW AS A GUIDE. N. COMPILE WRITTEN MANUAL OF OPERATING INSTRUCTIONS INCLUDING COPIES OF SHOP DRAWINGS AND LISTING OF EQUIPMENT SUPPLIERS. ASSEMBLE IN 8-1/2" X 11" HARD BACKED INDEXED BINDER. MATERIAL SHALL BE AS FOLLOWS: 1. TITLE PAGE: TITLE OF JOB, OWNER, ADDRESS, DATE OF SUBMISSION, CONTRACTOR AND ENGINEER. 2. INDEX. 3. LIST OF MAJOR EQUIPMENT USED IN PROJECT ACCOMPANIED BY CONTRACTOR PURCHASE ORDER NUMBERS AND SUPPLIERS NAMES AND ADDRESSES. 4. ONE COPY OF EACH SHOP DRAWING GROUPED BY TYPES OF EQUIPMENT, I.E., ROOFTOP UNITS, FANS, ETC. 5. SECTION FOR EACH SYSTEM INCLUDING: a. BRIEF DESCRIPTION OF SYSTEM OPERATION WITH LOCATION OF MAJOR COMPONENTS. b. HVAC SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS AND SCHEMATICS. O. SUBMIT A COMPLETED COPY TITLED "HVAC OPERATING INSTRUCTION MANUAL" ON BINDING EDGE OF BINDER TO ARCHITECT FOR APPROVAL. AFTER ARCHITECT'S REVIEW AND ANY CORRECTIONS REQUIRED ARE COMPLETED, SUBMIT A COPY OF THE MANUAL TO OWNER. P. WITHIN 90 DAYS AFTER DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF ACTUAL INSTALLATION SHALL BE PROVIDED TO BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AT A MINIMUM LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT DISTRIBUTION SYSTEM INCLUDING SIZES, AND AIR DESIGN FLOW RATES. Q. CONTRACTOR IS TO BECOME INFORMED OF EXACT DIMENSIONS OF FINISHED WORK WHERE PIPES, DUCTS AND EQUIPMENT ARE TO BE PLACED AND WILL ARRANGE THE WORK ACCORDINGLY, ASSUMING ALL RESPONSIBILITY FOR PROPER LOCATION AND COORDINATION OF THE WORK. R. IN ERECTION OF DUCTWORK, SPECIAL CARE SHALL BE USED PROVIDING SUPPORT. S. DUCTWORK SHALL BE PLACED SO AS TO AVOID INTERFERENCES WITH PLUMBING PIPES, ELECTRIC CONDUITS OR PIPES OF OTHER CONTRACTORS. T. DUCTWORK SHALL BE PROVIDED WITH SUFFICIENT DISTANCE FROM WALLS, PIPES, AND OTHER OBSTACLES TO PERMIT APPLICATION OF FULL THICKNESS OF INSULATION SPECIFIED. 230593 TESTING, ADJUSTING, & BALANCING HVAC A. CONTRACTOR SHALL COMPLETE INSTALLATION OF HOOD SYSTEM, ROOFTOP EQUIPMENT, AND CONTROL SYSTEM IN ACCORDANCE WITH DRAWINGS PRIOR TO PERFORMING TAB. CONTRACTOR SHALL PROGRAM THERMOSTATS IN ACCORDANCE WITH REQUIREMENTS LISTED AND FOLLOWING STATUS AS INDICATED IN TAB CONFIRMATION FORM. CONTRACTOR SHALL UTILIZE PERSONNEL AND SUBCONTRACTORS THAT ARE FULLY TRAINED AND CERTIFIED BY MANUFACTURER FOR EQUIPMENT BEING INSTALLED. B. CONTRACTOR SHALL COMPLETE CALIBRATIONS AND TESTS OUTLINED IN WENDY'S TEST PROTOCOLS AND DOCUMENT RESULTS ON DESIGNATED FORMS. COPIES OF FORMS ARE AVAILABLE ONLINE: HTTP://WWW.IGNITORLABS.COM/WRVT-DOC-HOME/ C. CONTRACTORS WORKING ON PROJECT ARE REQUIRED TO HAVE COMPLETED WENDY'S RESTAURANT VENTILATION COURSE FROM IGNITOR LABS WITHIN PAST 12 MONTHS: HTTPS://PORTAL.IGNITORLABS.COM A COMPLETION CERTIFICATE FROM IGNITOR LABS WITH A SCORE OF 80% OR HIGHER IS REQUIRED. CONTRACTOR IS RESPONSIBLE FOR THE NOMINAL COSTS REQUIRED FOR PROJECT PERSONNEL TO TAKE THE COURSE. D. PROCEDURES/CHECKLISTS: CHECKLIST PROCEDURE TROUBLESHOOTING BREAKER PANELS WESCO RQC-2017-013 RQC-2017-014 RQC-2017-015 CPI RQC-2017-043 RQC-2017-044 RQC-2017-045 ROOFTOP UNITS AAON RQC-2020-075 RQC-2020-076 RQC-2020-077 TRANE RQC-2020-025 RQC-2020-026 RQC-2020-027 YORK/CAPTIVE-AIR RQC-2020-105 RQC-2020-106 RQC-2020-107 HOOD SYSTEM HALTON (CAPTUREJET) RQC-2020-052 RQC-2020-053 HALTON (STANDARD FILTER HOOD) RQC-2020-054 RQC-2020-055 CAPTIVE-AIRE RQC-2020-062 RQC-2020-063 E. QUALIFICATIONS: 1. BALANCER SHALL BE A MEMBER IN GOOD STANDING AND CERTIFIED WITH THE ASSOCIATED AIR BALANCE COUNCIL (AABC), OR THE NATIONAL ENVIRONMENTAL BALANCING BUREAU (NEBB). BALANCER SHALL BE TOTALLY INDEPENDENT, HAVING NO AFFILIATION WITH ANY PROJECT CONTRACTOR, DESIGN PROFESSIONAL, EQUIPMENT MANUFACTURER OR SUPPLIER OF HVAC RELATED EQUIPMENT. BALANCER SHALL HAVE BEEN REGULARLY ENGAGED IN TAB OF HEATING, VENTILATING, AND AIR CONDITIONING SYSTEMS FOR RESTAURANTS. BALANCER SHALL PROVIDE PROOF THAT PERSONNEL PERFORMING WORK HAVE SUCCESSFULLY COMPLETED AT LEAST FIVE RESTAURANT PROJECTS OF SIMILAR SIZE AND SCOPE. A COMPLETE LIST OF REFERENCE PROJECTS, INCLUDING NAME AND PHONE NUMBER OF CONFIRMING CONTACTS, SHALL BE SUBMITTED WITH QUOTE, IF REQUESTED. 2. INSTRUMENTS USED FOR TAB SHALL BE ACCURATELY CALIBRATED WITHIN TWELVE (12) MONTHS OF BALANCING AND MAINTAINED IN GOOD WORKING ORDER. PROVIDE RECORDS OF LAST CALIBRATION (AS REQUESTED) AND INCLUDE THIS SUMMARY IN THE FINAL TAB REPORT. ENGINEER OF RECORD, OR THEIR REPRESENTATIVE, MAY OBSERVE TAB ACTIVITIES. 3. UNLESS OTHERWISE NOTED RESTAURATEUR SHALL PROCURE SERVICES OF AND CONTRACT DIRECTLY WITH AN INDEPENDENT TAB CONTRACTOR (BALANCER) MEETING QUALIFICATIONS OF THIS SECTION. BALANCER SHALL TEST, BALANCE, AND ADJUST ALL AIR MOVING EQUIPMENT (RTUS AND FANS), AIR DISTRIBUTION DUCTS AND AIR DEVICES, EXHAUST SYSTEMS, AND TEMPERATURE CONTROL SYSTEMS. 4. IF CONTRACTOR IS REQUIRED TO PROCURE TAB SERVICES DIRECTLY, CONTRACTOR SHALL PROVIDE QUALIFICATIONS OF BALANCER TO RESTAURATEUR OR THEIR REPRESENTATIVE FOR APPROVAL. CONTRACTOR SHALL CONTRACT BALANCER AS SOON AS POSSIBLE AFTER CONSTRUCTION START TO COORDINATE THEIR WORK WITH OTHER TRADES, WHILE MEETING COMPLETION DATE. CONTRACTOR SHALL PREPARE A CRITICAL PATH SCHEDULE, COORDINATED WITH SUBCONTRACTORS, TO ACCOMPLISH ALL TASKS REQUIRED OF BALANCER. 5. CONTRACTORS SHALL COOPERATE AND ASSIST BALANCER AS REQUIRED. BALANCER SHALL INSPECT MECHANICAL, EXHAUST, AND CONTROL SYSTEM WORK. ANY DEVIATIONS FROM PLANS AND SPECIFICATIONS THAT MAY AFFECT PERFORMANCE OF THE SYSTEM SHALL BE REPORTED IN WRITING TO CONTRACTOR, ARCHITECT OF RECORD, ENGINEER AND RESTAURATEUR. F. CONTRACTOR SHALL COMPLETE THE FOLLOWING PRIOR TO TAB: PERMANENT POWER SHALL BE PROVIDED, ROOFTOP UNIT FULL INSTALLED AND STARTED, HOOD SYSTEMS AND FANS STARTED, COMPLETE CONTROLS OPERATIONAL AND PROGRAMMED, DUCTWORK, DIFFUSER AND CEILING INSTALLATION COMPLETED. ADDITIONAL TAB COSTS ARE THE CONTRACTOR'S RESPONSIBILITY IF REQUIRED ITEMS ARE NOT COMPLETE AT START OF TAB PROCEDURES. G. DESIGN BALANCE DEVIATION TOLERANCES: 1. KITCHEN HOODS ARE UL LISTED AND SHALL BE BALANCED FROM 100% TO 105% OF DESIGN AIRFLOW. DO NOT SET EXHAUST RATE BELOW THAT SCHEDULED. INCREASE RTU AIRFLOW AS NEEDED TO ACHIEVE POSITIVE PRESSURE IN THE RESTAURANT. 2. TOTAL OF ALL AIR DISTRIBUTION DEVICES ON SAME ROOFTOP UNIT DUCT SYSTEM SHALL BE BALANCED TO 100% TO 105% OF DESIGN. 3. ROOFTOP UNITS SHALL PROVIDE OUTDOOR AIR CFM BETWEEN 100% TO 105% OF DESIGN FOR ALL SUPPLY FAN SPEEDS DURING REGULAR HOURS AND SHALL BE SET TO TRACK AIR VOLUME WITH THE SUPPLY FAN FOR THE FAN SPEED PROVIDED BY THE UNITS. 4. ECONOMIZERS SHALL PROVIDE REQUIRED OUTDOOR AIR WHEN CLOSED FOR BUSINESS (MINIMUM ONLY). 5. OVERALL SYSTEM SHALL BE BALANCED TO POSITIVE CFM AS SHOWN ON THE VENTILATION SCHEDULE WITH SUPPLY AND EXHAUST FANS IN OPERATION. 6. CONTACT RTU MANUFACTURER TO RESOLVE AIRFLOW DELIVERY IF ROOFTOP UNIT AIRFLOWS ARE BELOW DESIGN. THIS INCLUDES VERIFICATION OF DUCTWORK STATIC PRESSURE, ADJUSTMENT OF FAN RPM, REPLACEMENT OF DRIVES, ETC. RESTAURANT SHALL BE LEFT IN A POSITIVE AIR PRESSURE STATE. H. PLAN REVIEW: PROVIDE WRITTEN TESTING AND BALANCING PLAN REVIEW WITHIN FIVE (5) BUSINESS DAYS UPON RECEIPT OF CONTRACT. PLAN REVIEW SHALL INCLUDE RECOMMENDATIONS TO IMPROVE TESTING AND BALANCING. TRANSMIT THESE COMMENTS DIRECTLY TO CONTRACTOR. REVIEW WENDY'S RESTAURANT VENTILATION EQUIPMENT PRE-START AND START-UP FORMS. I. EQUIPMENT SUBMITTAL DATA: CONTRACTOR SHALL PROVIDE RESTAURANT EQUIPMENT SUBMITTAL DATA TO BALANCER. COMPLETED EQUIPMENT STARTUP AND CALIBRATION FORMS SHALL BE PROVIDED TO BALANCER PRIOR TO PERFORMING TAB. J. UPDATED DESIGN REQUIREMENTS: IF ANY, SHALL BE PROVIDED TO BALANCER PRIOR TO TAB. DESIGN REQUIREMENT CHANGES SHALL INCLUDE DATE OF THE CHANGE AND REFERENCES TO THE CONTRACT DOCUMENTS (ADDENDA, CHANGE ORDER, OR CONSTRUCTION CHANGE DIRECTIVE), WHICH DIRECTED THE CHANGE. CHANGES MADE WITHOUT RESTAURATEUR WRITTEN APPROVAL ARE INVALID. K. BALANCER TEST AND BALANCE REPORT: 1. PERFORM TAB WORK ASSOCIATED WITH THE RESTAURANT VENTILATION SYSTEM PER DESIGN DOCUMENTS. SUBMIT AN ELECTRONIC PDF COPY OF TABULATED REPORTS IN NEATLY ORGANIZED TYPED FORMS (WITH NUMBERED PAGES) WITH AABC OR NEBB FULLY COMPLETED, STAMPED AND SEALED REPORTS. REPORT SHALL BE PROVIDED WITHIN SEVEN (7) DAYS OF COMPLETION OF TESTS TO ARCHITECT OF RECORD, ENGINEER, CONTRACTOR AND RESTAURATEUR. REPORT SHALL INCLUDE START-UP CHECKLIST FORMS AND REPORTS PROVIDED TO BALANCER BY CONTRACTOR, EQUIPMENT TEST DATA AND DRAWINGS TO COINCIDE WITH TEST REPORT. IN ADDITION, REPORTS SHALL INCORPORATE: 2. A SUMMARY THAT SHALL INCLUDE A GENERAL DESCRIPTION OF PROJECT (BUILDING TYPE, SYSTEM TYPE, AND EQUIPMENT DESCRIPTION). 3. A DESCRIPTIVE LIST OF ALL EQUIPMENT AND TEST RESULTS THAT DO NOT MEET PLANS AND SPECIFICATIONS (INCLUDE PHOTOGRAPHS). 4. COPIES OF REDUCED PLAN DRAWINGS THAT UNIQUELY IDENTIFY AND CROSS REFERENCE AIR DEVICES AND HVAC EQUIPMENT. 5. PROVIDE BUILDING PRESSURE TABLES THAT INDICATE DESIGN AND ACTUAL RESULTS. 6. REPORTS THAT ARCHITECT AND/OR ENGINEER DETERMINES IS INACCURATE, OR INCOMPLETE, SHALL BE RETURNED FOR CORRECTION, COMPLETION, OR RE-TESTING AT BALANCERS COST. REVISED REPORTS SHALL BE SUBMITTED IN THEIR ENTIRETY. EACH REVISION SHALL BE HIGHLIGHTED AND SHALL INDICATE REVISION DATE. COVER PAGE SHALL INDICATE DATE OF FIRST EDITION AND REVISION DATE. L. TEST & BALANCE CONFIRMATION FORM: BALANCER SHALL COMPLETE A WENDY'S TEST & BALANCE CONFIRMATION FORM WHILE PERFORMING SYSTEM TESTING. IT SHALL BE SIGNED OFF WHEN TAB IS COMPLETE AND INCLUDED AT THE END OF THE TEST AND BALANCE REPORT. A DIGITAL VERSION OF THIS FORM CAN BE FOUND UNDER TEST AND BALANCE REPORTS AT: HTTP://WWW.IGNITORLABS.COM/WRVT-DOC-HOME/ M. CONTRACTOR'S RESPONSIBILITIES FOR TAB: 1. CONTRACTOR SHALL BE COMPLETELY FAMILIAR WITH ALL PROVISIONS AND RESPONSIBILITIES OF BALANCER AND SHALL PROVIDE COOPERATION AND SUPPORT REQUIRED. 2. CONTRACTOR SHALL CORRECT OR REPAIR DEFICIENCIES NOTED BY BALANCER IMMEDIATELY. IF DEFICIENCIES ARE NOT CORRECTED WHILE BALANCER IS ON SITE, AND DEFICIENCIES PREVENT COMPLETION OF TAB WORK, CONTRACTOR SHALL ASSUME COSTS FOR EXTENDING TAB, OR FOR FOLLOW UP TAB VISITS. 3. CONTRACTOR SHALL PROVIDE DOCUMENTATION OF CORRECTION OF ANY OPEN ISSUES PRIOR TO SUBMISSION OF FINAL REPORT. SHOULD ANY OPEN HVAC SYSTEM ITEMS BE INCAPABLE OF CORRECTION WITHIN SEVEN DAY PERIOD FOR THE FINAL BALANCING REPORT, CONTRACTOR SHALL INFORM BALANCER AND OWNER IMMEDIATELY AND CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS, DELAYS, AND RESCHEDULING REQUIRED. 4. CONTRACTOR IS RESPONSIBLE FOR CORRECTION OF IDENTIFIED ITEMS AND FOR SUBSEQUENT TESTS IN EVENT OF THE FOLLOWING: a. NO PERMANENT POWER FOR THE RESTAURANT. b. DIFFUSERS NOT INSTALLED FOR TEST. c. CEILING TILES NOT INSTALLED. d. PASSWORD FOR RTU THERMOSTATS NOT PROVIDED. e. INOPERABLE EQUIPMENT. f. THERMOSTATS NOT PROGRAMMED. 5. ADDITIONAL RESPONSIBILITIES INCLUDE; PROVIDE REQUIRED SHOP DRAWINGS AND EQUIPMENT DATA INCLUDING ANY APPROVALS OF DESIGN MODIFICATIONS, PROVIDE SAFE AND CLEAR ACCESS TO ALL HVAC SYSTEMS AS NEEDED TO PERFORM TAB WORK (LADDERS, LIFTS, ROOF ACCESS, ACCESS PANELS AND THE LIKE), PROVIDE TEST OPENINGS AS REQUIRED FOR TESTING AND BALANCING HVAC SYSTEMS, PROVIDE UPDATED JOB SCHEDULE AND TIMELY NOTICE PRIOR TO SCHEDULED EVENTS. MAKE TESTS AND CALIBRATION TO ESTABLISH ADEQUACY, QUALITY, SAFETY, COMPLETED STATUS, AND SATISFACTORY OPERATION OF HVAC SYSTEMS AND COMPONENTS. 6. DURING TAB PERIOD, OPERATE HVAC EQUIPMENT AS NECESSARY TO PERMIT SYSTEMS TO BE TESTED AND BALANCED AS FULLY OPERATING FUNCTIONAL SYSTEMS. WORK HARMONIOUSLY WITH BALANCER TO EXPEDITE THE WORK. REMOVE AND REPLACE CEILINGS AS NECESSARY TO PERMIT TAB OPERATIONS. REMOVE AND REPLACE EQUIPMENT, LIGHTS, OR OTHER ITEMS WHICH OBSTRUCT TESTING AND BALANCING OPERATIONS (WHERE EQUIPMENT, LIGHTS, OR OTHER ITEMS INTERFERE WITH FUTURE ADJUSTMENTS OF HVAC SYSTEM. SUCH EQUIPMENT, LIGHTS, OR OTHER ITEMS SHALL BE RELOCATED BY CONTRACTOR AS DIRECTED BY ENGINEER OF RECORD. 7. REPLACE BELTS AND DRIVES AS REQUIRED FOR PROPER BALANCING - DRIVES SHALL BE ADJUSTED AND ALIGNED BY CONTRACTOR TO PREVENT ABNORMAL BELT WEAR AND VIBRATION. ADJUST FAN SPEED AS REQUIRED NOT TO EXCEED MOTOR CAPACITY. CONTRACTOR SHALL ADJUST DAMPERS FOR THE BALANCER DURING TAB WORK. IDENTIFY CONCEALED DAMPER LOCATIONS WITH ORANGE TAPE. MANUALLY OPEN AND TEST DAMPERS FOR SMOOTH VIBRATION-FREE OPERATION AND TIGHTEN PRIOR TO COMMENCEMENT OF TAB WORK. VERIFY THAT ALL CONTROLS ARE INSTALLED AND OPERATING AS REQUIRED IN BOTH STORE OPEN AND CLOSED MODES. BEFORE REQUESTING FINAL TESTING AND BALANCING, SUBMIT SIGNED STATEMENT THAT HVAC SYSTEMS ARE INSTALLED, ADJUSTED, SERVICED, OPERATING SATISFACTORILY, AND ARE READY FOR USE. N. SYSTEM READY NOTICE: ALLOW ADEQUATE TIME TO PERFORM TESTING AND BALANCING WORK. TAB IS REQUIRED TO BE PERFORMED PRIOR TO RESTAURANT OPENING. NOTIFY BALANCER UPON COMMENCEMENT OF WORK RELATED TO HVAC SYSTEM AND COORDINATE PROPER TIME FOR NOTICE TO SCHEDULE TRAVEL AND PROVIDE THE DURATION REQUIRED FOR TEST AND BALANCING AND FOR ANY POSSIBLE CORRECTIONS. O. BALANCER RESPONSIBILITIES: 1. RECORD DATA REQUIRED BY AABC OR NEBB FORMS. TEST AND ADJUST SYSTEMS FOR DESIGN CFM OF SUPPLY, OUTSIDE AIR (IN MULTIPLE FAN SPEEDS), AND EXHAUST AIR. KITCHEN APPLIANCES SHOULD BE OPERATIONAL WHILE MAKING ADJUSTMENTS. HOOD SIDE SKIRTS SHALL BE IN PLACE ON THE CORRECT ENDS OF HOODS (FRY HOOD DUMP SKIRT HAS A CUT OUT). TEST AND RECORD SYSTEM STATIC PRESSURE PROFILES. ADJUST SUPPLY AND RETURN DUCTS TO DESIGN AIRFLOW. TEST AND ADJUST FANS. ADJUST ALL DIFFUSERS, GRILLES, AND REGISTERS TO MINIMIZE DRAFTS. PROVIDE BUILDING DIFFERENTIAL PRESSURE (INSIDE TO OUTSIDE) AT ALL OPERATIONAL CONDITIONS AND INCLUDE IN THE FINAL REPORT. 2. PROVIDE TABLE IN THE REPORT THAT ITEMIZES ALL SUPPLY AND EXHAUST AIR CFM (SPECIFIED AND ACTUAL) TO SHOW THAT BUILDING SHOULD BE UNDER POSITIVE PRESSURE. SIZE, Ak CATALOG FACTORS OF DIFFUSERS, GRILLES, REGISTERS, AND ALL TESTED EQUIPMENT SHALL BE IDENTIFIED AND LISTED. READINGS AND TEST OF DIFFUSERS, GRILLES, AND REGISTERS SHALL INCLUDE REQUIRED VELOCITY (FPM), REQUIRED CFM, AND RESULTANT CFM. WHEN DIRECT CFM MEASURING INSTRUMENTS ARE USED, VELOCITIES ARE NOT REQUIRED. 3. BALANCER SHALL COMPLETE A WENDY'S TEST & BALANCE CONFIRMATION FORM WHILE PERFORMING SYSTEM TESTING. FORM SHALL BE SIGNED OFF WHEN TAB IS COMPLETE AND INCLUDED AT THE END OF TAB REPORT. 230700 HVAC INSULATION A. DUCT INSULATION AND APPURTENANCES SHALL HAVE FLAME SPREAD RATING NOT EXCEEDING TWENTY-FIVE (25) AND SMOKE DEVELOPED RATING NOT EXCEEDING FIFTY (50). DUCT INSULATION SHALL HAVE AN INSTALLED R-VALUE OF 6. B. CONCEALED SUPPLY DUCTWORK SHALL HAVE FLEXIBLE FIBERGLASS DUCT WRAP LAMINATED TO FOIL REINFORCED KRAFT VAPOR BARRIER FACING WITH 2" STAPLING FLANGE OF SUFFICIENT DENSITY AND THICKNESS TO MEET LOCAL CODE REQUIREMENTS. ONLY COMMERCIAL GRADE INSULATION PRODUCTS MAY BE USED. C. INSULATION SHALL NOT BE APPLIED UNTIL CONSTRUCTION HAS PROGRESSED SUFFICIENTLY TO ENSURE AGAINST PHYSICAL OR MOISTURE DAMAGE TO INSULATION. INSULATION DAMAGED THROUGH FAILURE TO OBSERVE THIS DIRECTIVE SHALL BE REPLACED AT THIS CONTRACTOR'S EXPENSE. D. HANGER RODS SHALL BE PERPENDICULAR TO DUCTWORK BEFORE INSULATION IS INSTALLED. E. INSTALL INSULATION ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. F. INSULATION SHALL BE APPLIED OVER FLANGES, JOINTS AND SEAMS IN PIPING AND DUCTWORK. G. JOINTS AND SEAMS IN INSULATION SHALL BE PROPERLY SEALED TO MAINTAIN VAPOR BARRIER. H. INSULATION SHALL BE OWENS-CORNING. EQUAL PRODUCT BY ARMSTRONG, CERTAINTEED, SCHULLER OR KNAUF MAY BE PROVIDED AT CONTRACTOR'S OPTION. 230800 COMMISSIONING OF HVAC A. THIS CONTRACTOR SHALL COORDINATE COMMISSIONING OF HVAC SYSTEMS AND SHALL ASSIST OWNERS TAB CONTRACTOR TO COMPLETION. CONTRACTOR IS RESPONSIBLE FOR CORRECTING DEFICIENCIES NOTED IN THE TAB REPORT. C. CONTRACTOR SHALL PROVIDE DOCUMENTATION OF TESTING AND COMMISSIONING TO BE INCLUDED IN OPERATING INSTRUCTIONS MANUAL (SEE GENERAL REQUIREMENTS). DOCUMENTATION SHALL INCLUDE: 1. CONSTRUCTION AND SYSTEM CHECKLISTS. 2. CERTIFICATE OF READINESS. 3. INTERIM AND FINAL TEST AND INSPECTION REPORTS AND CERTIFICATES. 4. APPROVED SUBMITTALS. 5. CERTIFICATE OF COMPLETION. 6. AS-BUILT DOCUMENTATION. 233133 METAL DUCTS A. THIS SECTION INCLUDES SPECIFICATIONS FOR DUCTWORK EXCEPT 'GREASE DUCT' (EXHAUST DUCT CONNECTED TO TYPE I HOODS WHERE GREASE LADEN VAPORS MAY BE PRESENT). REFER TO PLANS AND DETAILS FOR INFORMATION ON 'GREASE DUCT'. B. CONTRACTOR SHALL PROVIDE COMPLETE DUCT SYSTEM CONSISTING OF DUCTWORK, PLENUMS, FITTINGS AND CONNECTORS OF SIZE AND LOCATION AS INDICATED ON DRAWINGS. C. ALL PORTIONS OF DUCT SYSTEM SHALL BE DESIGNED, FABRICATED AND INSTALLED PER THE FOLLOWING REQUIREMENTS: 1. LATEST EDITION OF SMACNA “HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE”. 2. RIGID GALVANIZED SHEET METAL OF THICKNESS AND WITH STIFFENERS AS INDICATED IN SMACNA PER 2” WATER COLUMN CHART. 3. AIR VELOCITIES NO MORE THAN 2000 FPM AND STATIC PRESSURE IN DUCT OF 2” OR LESS. 4. SEALING PER SMACNA 'CLASS B' OR AS REQUIRED TO MEET AIR BALANCE. 5. CROSS-BREAKING, STIFFENING, BRACES, TOES, ANGLES AND OTHER BRACING AND SUPPORT REQUIRED TO MAINTAIN DUCT CONFORMITY (TRUE TO SHAPE, PREVENT BUCKLING OR CAVITATION). 6. ALL VERTICAL DUCTS SHALL BE ABLE TO CARRY AN ADDITIONAL 100 LBS. SUSPENDED LOAD FROM HANGERS WITHOUT BUCKLING. 7. SEAMS OF ALL DUCTS AND JOINTS SHALL BE HAMMERED TO A SMOOTH SURFACE ON THE INSIDE. D. FLEXIBLE CONNECTIONS SHALL BE INSTALLED AT ROOFTOP UNIT SUPPLY AND RETURN AIR CONNECTIONS. CONNECTIONS SHALL BE AT LEAST 6" LONG, MADE OF NFPA 90A APPROVED FLAMEPROOF FABRIC. E. INSTALL HANGERS AND SUPPORTS WITHIN 24 INCHES OF EACH ELBOW AND WITHIN 48 INCHES OF EVERY BRANCH CONNECTION. HANGERS EXPOSED TO VEIW SHALL BE THREADED ROD AND ANGLE OR CHANNEL SUPPORTS. F. ROUND SHEET METAL DUCT: PROVIDE SPIRAL SEAM (ALL SIZES) OR SNAP LOCK (DUCT CONCEALED ABOVE CEILINGS SIZES UP TO 10") GALVANIZED STEEL COMPLYING WITH SMACNA STANDARDS. SPIRAL SEAM DUCTWORK SHALL HAVE SMACNA SEAM TYPE RL-1. ROUND EXPOSED DUCTWORK SHALL BE SPIRAL SEAM (ALL SIZES). G. EXPOSED DUCTWORK: EXPOSED DUCTWORK SHALL BE CLEANED OF DEBRIS AND OIL, THEN WIPED DOWN WITH VINEGAR OR OTHER SURFACE PREPARING CHEMICAL TO PREPARE DUCT FOR PAINT. H. PROVIDE VOLUME CONTROLLER AND EXTRACTOR AT BRANCH TAKEOFFS IN SUPPLY AND RETURN AND AT OTHER LOCATIONS IN SUPPLY AND RETURN MAIN DUCTS AS REQUIRED TO PROPERLY BALANCE SYSTEMS. DAMPER SHALL BE AS SPECIFIED IN SECTION 233300. I. PROVIDE TURNING VANES IN ELBOWS OF RECTANGULAR SUPPLY DUCTS. BLADES SHALL BE HOLLOW-FORMED DOUBLE THICKNESS VANES. J. PROVIDE SUPPLY, RETURN, AND EXHAUST REGISTERS, GRILLES AND DIFFUSERS AS INDICATED ON DRAWINGS AND/OR SCHEDULES. VERIFY AIR DEVICE REQUIREMENTS WITH GENERAL CONTRACTOR PRIOR TO ORDERING. K. PROVIDE FLEXIBLE SUPPLY AIR DUCTWORK UL 181, CLASS 1, TWO-PLY VINYL FILM SUPPORTED BY HELICALLY WOUND SPRING-STEEL WIRE, R-6 FIBERGLASS BLANKET INSULATION WITH METALIZED FILM VAPOR BARRIER OUTER JACKET IN LENGTHS THAT DO NOT EXCEED SIX FEET, AT AIR DEVICE CONNECTIONS (GRILLES, REGISTERS AND DIFFUSERS). 233300 DAMPERS A. CONTRACTOR SHALL PROVIDE RECTANGULAR AND ROUND GALVANIZED STEEL MANUAL AND/OR MOTORIZED VOLUME CONTROL DAMPERS THAT SHALL BE: 1. NO MORE THAN 6" IN ONE DIMENSION (LARGER DAMPERS SHALL BE OPPOSED-BLADE WITH EACH BLADE BEING NO MORE THAN 6”), 2. MINIMUM OF 16 GAUGE AND AT LEAST 2 GAUGES HEAVIER THAN DUCT INSTALLED IN, 3. CHANNEL FRAME WITH BRACED CORNERS, CONCEALED LINKAGE, TEFLON FILLED BEARINGS, BLADE STOPS 4. REPLACEABLE BUTYL RUBBER SEALS INSTALLED ALONG TOP, BOTTOM AND SIDES OF FRAME AS WELL AS ALONG ALL SIDES OF EACH BLADE 5. 6" LONG CONTROL SHAFT WITH INSULATION STAND-OFF, 6. LOCKING QUADRANT MANUAL HANDLES OR MOTORIZED OPERATORS COMPATIBLE WITH CONTROL SYSTEM, 7. OPERATE FROM FULL OPEN TO FULL CLOSED. B. PROVIDE ACCESS AND PROPER CLEARANCES AS REQUIRED TO OPERATE DAMPERS. C. CHECK DAMPERS FOR PROPER OPERATION BEFORE AND AFTER INSTALLATION. D. INSTALL BALANCE DAMPERS WHERE INDICATED ON DRAWINGS AND ELSEWHERE AS NECESSARY TO OBTAIN PROPER SYSTEM BALANCE. 233418 ROOF EXHAUST FAN A. ROOF MOUNTED UP BLAST EXHAUST FAN SHALL BE CENTRIFUGAL DIRECT DRIVE TYPE. FAN SHALL BE CONSTRUCTED OF SPUN ALUMINUM WITH STRUCTURAL ELEMENTS OF MINIMUM 16 GAUGE MARINE ALLOY ALUMINUM. B. INTEGRAL MOTOR SHALL BE HEAVY DUTY TYPE WITH PERMANENTLY LUBRICATED SEALED BEARINGS ENCLOSED IN WEATHER-TIGHT COMPARTMENT AND SEPARATED FROM THE EXHAUST AIR STREAM. C. THE WHEEL SHALL BE CENTRIFUGAL BACKWARD INCLINED TYPE WITH COMPLETELY ALUMINUM CONSTRUCTION WITH CONE INLET AND DYNAMICALLY BALANCED TO MINIMIZE VIBRATION. D. FANS SHALL BEAR THE AMCA CERTIFIED RATINGS SEAL FOR SOUND AND AIR PERFORMANCE AND SHALL BE UL LISTED AND CSA APPROVED. CAPACITIES AS SHOWN ON THE DRAWINGS. E. WIRING SHALL BE BY ELECTRICAL CONTRACTOR. F. VERIFY MANUFACTURER MAKE AND MODEL OF EXHAUST FANS WITH HOOD DRAWINGS. 233713 AIR DISTRIBUTION DEVICES A. DIFFUSERS, REGISTERS AND GRILLES SHALL BE PROVIDED BY CONTRACTOR. B. COORDINATE AIR DISTRIBUTION DEVICE LOCATIONS WITH AFFECTED CONTRACTORS BEFORE INSTALLING DUCTWORK. CHANGES IN LOCATION FROM THE DRAWINGS MUST BE APPROVED BY OWNER BEFORE INSTALLATION. C. SUSPEND CEILING AIR DEVICES FROM STRUCTURE ON WIRE HANGERS OR FROM RIGID DUCTWORK. CEILING MUST NOT BE USED TO SUPPORT AIR DISTRIBUTION DEVICES. D. SECURELY FASTEN SIDE WALL AIR DEVICES TO RIGID DUCTWORK OR STRUCTURE. 233813 - COMMERCIAL-KITCHEN HOODS A. PROVIDE SUBMITTALS ON TYPE I HOODS, FILTERS AND BAFFLES, AND LIGHTING FIXTURES. B. COORDINATE WITH KITCHEN EQUIPMENT LAYOUT, LIGHTING FIXTURES, HVAC EQUIPMENT, PLUMBING, SPRINKLER SYSTEM, AND FIRE-SUPPRESSION SYSTEM COMPONENTS. C. TYPE I HOOD SHALL BE MANUFACTURED OF STAINLESS STEEL ASTM A 666, TYPE 304 STEEL WITH MINIMUM THICKNESS OF 0.050". D. TYPE I HOODS SHALL BE WELDED AT ALL JOINTS EXPOSED TO GREASE WITH CONTINUOUS WELDS, HAVE EASILY ACCESSIBLE FILTERS/BAFFLES, AND MAKE-UP AIR DIFFUSERS EASILY ACCESSIBLE FOR CLEANING. HOODS SHALL BE FABRICATED ACCORDING TO FSF2 AND UL 710 LISTED AND LABELED. E. PROVIDE ACCESS PANELS FOR FIRE DAMPERS AND FUSIBLE LINKS. F. DUCT-COLLAR FIRE DAMPERS - COLLAR AND DAMPER SHALL COMPLY WITH UL 710 TESTING AND LISTING REQUIRED FOR THE ENTIRE HOOD. G. LIGHTING FIXTURES - LIGHTING FIXTURES ARE PROVIDED IN THE LIGHTING PACKAGE. LED HEAT RATED LAMPS AT 3500K ARE REQUIRED. SUBSTITUTION OF CFL OR INCANDESCENT LAMPS IS NOT AUTHORIZED. H. HOOD CONTROLS - HOOD CONTROLS SHALL BE ENCLOSED WITHIN A WALL MOUNTED CONTROL PANEL, FACTORY WIRED AND FABRICATED OF STAINLESS STEEL. ON-OFF SWITCHES SHALL START AND STOP THE EXHAUST FAN WITH AN INTERLOCK FOR THE SUPPLY FAN TO OPERATE SIMULTANEOUSLY. INTERLOCK EXHAUST FAN WITH FIRE-SUPPRESSION SYSTEM TO OPERATE FAN DURING FIRE-SUPPESSION-AGENT RELEASE AND TO REMAIN IN OPERATION UNTIL MANUALLY STOPPED. 12 / 2 2 / 2 0 1 7 4 : 1 3 : 4 7 P M 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments MECHANICAL SPECIFICATIONS M4.0 OM DRC TOTAL EXH. CFM = 20" 11"L0502 EO 1500 1 5 - 13" 13"KSA EXPO 18 GA. 430 S.S. 48612" 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments HOOD DETAILS H1.1 HALTON HALTON TOTAL EXH. CFM = 20" 11"L0307 EO 1100 - - 1 3 - 13" 13"KSA EXPO 18 GA. 430 S.S. 38512" 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments HOOD DETAILS H1.2 HALTON HALTON 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments HOOD DETAILS H1.3 HALTON HALTON SP MAXLITE LED MAXLITE LED MAXLITE LED EX T . R A M P MA X L I T E LE D MAXLITE LED MA X L I T E LE D MAXLITE LED LCA672LCE6120 MAXLITE LED MAXLITE LED 1LIGHTING PLAN 1/4" = 1'-0" DINING 101 A- 6 A7 T2 T2 EX1B A7 6' P4L P4L EX1B T2 T2 6' A- 2 SWITCH E A7 4' T2 2' T2 EM2B A7 EM2B A7 A7 8 6 2 J J J #10 A7/NL A7/NL SWITCH C TL1 EX1RB T2T T2T T2T T2T T2 A7 A7 A7 A-12 SWITCH B A6 T1 T1 P4L P4L SWITCH D SWITCH C A7/NL T1 T1 T1 SWITCH D K12A-2 #10 T1 A6 A-2 TL1 8 8 TL1 K12 K12 K12A-2 #10 K12K12 K12 2 A-4 J 7 A-2#10 A1 OS1 EM2WEM2W A-17 OS1 OS OS OS1 OS A1 A1 A1 A1 EM2W A1 A1 A1 A1A1 A1 5 A1/NL A-33 SWITCH A A1/NL J EM2W 4 NL B4B4 B4 EM2W NL B4B4 B4 B4 EM2W 1 1 33 3 HL1HL1HL1 3 HL1 3 HL1 J J C-21 2 B4/NL A-8 J #10 NL B4 NL B4 NL B4 B4 B4B4 B4 B4B4 B4 B4 OS EM2W A-13 B4 B4 EX1W D EX1RB WP4 WB1 EX1W OS2OS A-11 OS2 OS WB1 WB1 WB1 WB1 WB1 WB1 WB1WB1 K12 K12 A-2 OS2 OS T1 T1 B4 T1 K12 A- 16 2 J #10 EM2W EM2W FAMILY 103 FAMILY 102OFFICE 108 FREEZER 110 RECEIVING 112 COOLER 111 CREW 114 KITCHEN 106 DRIVE THRU 105 PAY WINDOW 113 SERVICE 104 UTILITY 116 ENTRY 100 12 / 2 2 / 2 0 1 7 4 : 0 9 : 5 0 P M LIGHTING PLAN E1.1 KH MJ 79 6 M e r u s C o u r t St . L o u i s , M O 6 3 0 2 6 T 6 3 6 . 3 4 9 . 1 6 0 0 F 6 3 6 . 3 4 9 . 1 7 3 0 CE R T I F I C A T E O F A U T H O R I T Y N O . 3 8 0 0 8/18/2021 SEAL DESCRIPTIONDATEREV. ISSUE DATE: 08/17/2021 PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ 1 10/20/2021 City Comments A-2 B1 RECESSED CAN LIGHT FIXTURE RECESSED CAN NIGHT LIGHT FIXTURE LED LIGHT FIXTURE LED NIGHT LIGHT FIXTURE HANGING LIGHT FIXTURE MONO POINT LIGHT FIXTURE EMERGENCY REMOTE EGRESS HEAD CIRCUIT NUMBER FIXTURE SYMBOL OCCUPANCY SENSOR (WALL MOUNTED OR CEILING MOUNTED) SINGLE POLE WALL SWITCH AT 4'-6" A.F.F. EMERGENCY FLOOR LIGHT (WALL MOUNTED OR CEILING SURFACE MOUNTED) DIMMER SWITCH, (LEVITON #IP710-DLZ-WH)D OS LIGHTING LEGEND LED TAPE LIGHT GLOBE PENDANT LIGHT PENDANT LIGHT TRACK HEAD BUILDING MOUNTED DECORATIVE LIGHT OS LIGHTING TRACK A. COORDINATE WORK WITH MECHANICAL, REFRIGERATION AND EQUIPMENT CONTRACTORS, INCLUDING COOLER/FREEZER WORK AND ICE MACHINE CONDENSING UNITS. B. VERIFY ROUGH-IN DIMENSIONS AND POWER REQUIREMENTS WITH KITCHEN EQUIPMENT DISTRIBUTOR PRIOR TO ROUGH-IN. C. PROVIDE FINAL CONNECTIONS WITHIN FRONT COUNTER, COOKCENTER PANEL, REMOTE REFRIGERATION UNITS, AND ICE MACHINE REMOTE UNIT WHEN INSTALLED BY VENDOR. D. VERIFY AVAILABLE FAULT CURRENT AT PRIMARY SERVICE AND COMPATIBILITY WITH MODULAR PANEL SYSTEM. E. ENSURE ADEQUATE CONDUIT SIZE FOR ELECTRICAL AND COMMUNICATION WIRING ON SITE AND INTO BUILDING. F. CIRCUITS MAY BE GROUPED WITHIN COMMON CONDUITS PER NEC REQUIREMENTS UNLESS NOTED OTHERWISE. G. PROVIDE WALL BOX WITH 1/2" CONDUIT WITH PULLSTRING AND NYLON BUSHING STUBBED ABOVE NEAREST ACCESSIBLE CEILING FOR THERMOSTATS, TEMPERATURE SENSORS, CARBON DIOXIDE SENSOR, AND HUMIDISTATS UNLESS OTHERWISE NOTED. H. WIRE ROOF TOP UNIT CONTROL CIRCUIT THROUGH AUXILIARY CONTACTS IN SMOKE DETECTOR AND MAKE ALL FINAL CONNECTIONS. (TYPICAL OF ALL ROOF TOP UNITS) I. COOKCENTER IS ASSEMBLED AND PREWIRED AT THE FACTORY. WIRING IS PROVIDED IN THE PRE- INSTALLED SPLICE BOX, COILED AND TAGGED. A LENGTH OF CONDUIT WITH WIRES IS PROVIDED FOR THE REMOTE CONDENSING ROOFTOP UNIT. RUNS POWER FROM THE SPLICE BOX TO THE COOKCENTER PANEL. J. ROOFTOP UNIT IS FACTORY PROVIDED WITH DISCONNECT AND UNPOWERED SERVICE RECEPTACLE. K. IN AREAS WITHOUT CEILINGS OR WHERE ANY CONDUITS, CONDUCTORS, FEEDERS. OR LOW- VOLTAGE WALL EMT CONDUIT. CABLING IS VISIBLE, ALL WIRING SHALL BE IN RIGID GALVANIZED STEEL (RGSC) OR THIN WALL EMT CONDUIT. BX, AC, AND MC CABLE ARE NOT PERMITTED. CONDUITS ARE TO BE RUN TIGHT TO DECK EITHER PARALLEL OR PERPENDICULAR TO BUILDING LINES AND ONLY DROP AT POINT OF CONNECTION. JUNCTION BOXES SHALL HAVE CIRCUIT NUMBERS WRITTEN ON THE INSIDE OF THE JUNCTION BOX COVER. L. SEAL ROOF PENETRATIONS PER ROOFING MANUFACTURER'S INSTRUCTIONS. M. COORDINATE WORK ABOVE THE CEILING WITH OTHER TRADES TO PROVIDE THE GREATEST POSSIBLE CLEARANCE.CONDUITS SHALL BE ROUTED IN THE DIRECTION OF THE TRUSSES. N. ONLY EMT CONDUITS ARE ALLOWED IN RECEIVING/DRY STORAGE. O. DEFINITIONS: FURNISH MEANS TO SUPPLY AND DELIVER TO PROJECT SITE, READY FOR INSTALLATION. INSTALL MEANS TO PLAN IN POSITION AND MAKE CONNECTIONS FOR SERVICE OR USE. PROVIDE MEANS TO FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED USE. 1. JUNCTION BOX ABOVE CEILING FOR HOOD LIGHTS AND EXHAUST HOOD. 2. PROVIDE WEATHERPROOF JUNCTION BOX AND TOGGLE TYPE 20A-1P DISCONNECT FOR SIGNAGE. COORDINATE EXACT REQUIREMENTS WITH SIGN CONTRACTOR. VERIFY LOCATION PRIOR TO ROUGH IN. 3. PROVIDE LAMP FOR HOOD LIGHT. SUBSTITUTION OF CFL OR INCANDESCENT LAMP IS PROHIBITED. 4. LOCATION OF LIGHTING SWITCH BANK. REFER TO SWITCH AND HOOD SUPPRESSION ELEVATION ON SHEET E5.2 FOR ADDITIONAL INFORMATION. 5. PROVIDE JUNCTION BOX AND SWITCH FOR ILLUMINATED MIRROR AT 4'-0" AFF AND CONNECT TO CIRCUIT SHOWN. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT MOUNTING LOCATION. 6. LED TAPE LIGHTING DRIVER MUST BE INSTALLED INSIDE OF BUILDING DUE TO TEMPERATURE RATING OF DRIVER. REFER TO LED DRIVER MOUNTING DETAIL, SHEET E5.2. 7. LIGHTS IN CANOPY PROVIDED BY CANOPY MANUFACTURER. 8. EXTERIOR LED TAPE LIGHTING 'TL1'. REFER TO ARCHITECTURAL SHEETS FOR MORE INFORMATION. VERIFY LENGTHS AND DRIVER REQUIREMENTS PRIOR TO INSTALLATION. REFER TO WALL PENETRATION DETAIL, SHEET E5.2. CODED NOTES:LIGHTING GENERAL NOTES A. CONNECT EXIT/EMERGENCY/NIGHT FIXTURES TO UNSWITCHED HOT CONDUCTOR AHEAD OF ANY LIGHTING CONTROLS. B. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND DETAILS FOR THE LOCATION OF ALL LIGHTING FIXTURES AND ALL OTHER CEILING MOUNTED EQUIPMENT. VERIFY MOUNTING HEIGHTS AND FINISHES WITH ARCHITECT PRIOR TO ROUGH-IN. C. REFER TO THE POWER PLANS FOR LOCATION OF ELECTRICAL EQUIPMENT. D. PROVIDE INDICATED CONDUCTOR SIZE FOR ENTIRE CIRCUIT WHERE CONDUCTOR SIZES ARE SHOWN ON HOMERUNS. E. PROVIDE A DEDICATED NEUTRAL WITH ALL DIMMING SYSTEM CIRCUITS. NO COMMON NEUTRALS SHALL BE ALLOWED. F. PROVIDE (2) ADDITIONAL #12 CONDUCTORS FOR ALL 0-10V DIMMING CIRCUITS.