Loading...
HomeMy WebLinkAboutREDLINED CIVIL PLANS - 21-00694 - 240 E Moody - Wendy's - New BuildingAuthor Name Author Email Author Phone No.: Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Tawnya Grover Tawnya.Grover@rexburg.org 208-372-2167 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Joel Gray Joel.Gray@rexburg.org 208-372-2331 Description : RPR6N40E173010 - Wendy's - New Building Address : RPR6N40E173010 Application Type : Document Filename : Wendys_Rexburg ID_Civil Plans.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments C1.0 Comment Kyle Baldwin : P&Z Open 1 Please remember to include Central Features and Community Spaces requirement See Section 6.00.040 C1.0 Callout Joel Gray : PW Open 1 How is this accessed? C1.0 Free text Joel Gray : PW Open 1 DEQ Approval required. Water rights transferred to City. Streetlight required. Location to be determined. C1.0 Callout Joel Gray : PW Open 1 Gates must open 180 degrees. Right side pickup. C1.0 Callout Joel Gray : PW Open 1 Sidewalk must be completed to 2nd East. C1.0 Callout Joel Gray : PW Open 1 Will stubs be capped? C1.0 Callout Joel Gray : PW Open 1 Owner to make sure parking stalls are empty on pickup day. C3.0 Callout Joel Gray : PW Open 3 What are inverts South and east? # 21-00694 New Commercial Building Report Date: 09.20.2021 Approval of plans does not constitute approval of variance from code Page 1 of 1 Powered by TCPDF (www.tcpdf.org) FUTURE BEE HIVE CREDIT UNION SEAL DESCRIPTIONDATEREV. ISSUE DATE: **/**/**** PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ GREBEIFRFF J E E R E E N I G NEONALSI E S ROF P  01 EXIST. SANITARY SEWER 02 EXIST. 16" WATER LINE 03 EXIST. FIRE HYDRANT 04 EXIST. WATER VALVE 05 EXIST. POWER POLE 06 EXIST. CURB & GUTTER, RETAIN & PROTECT 07 16" x 8" HOT TAP WITH 8" GATE VALVE (SEE SHEET 4) 08 8" CLASS 50 DUCTILE IRON WATER LINE (SEE SHEET 3.0) 09 20' - 8" CLASS 50 D.I. WATER LINE STUB 10 8" GATE VALVE 11 STD. FIRE HYDRANT RE: ISPWC SD-404 12 1 12" WATER SERVICE CONNECTION RE: CITY OF REXBURG STD. DWG. 402 13 1 12" INTERIOR WATER METER RE: CITY OF REXBURG STD. DWG. 402 14 1 12" HDPE WATER SERVICE LINE 15 1 12" HDPE LANDSCAPE WATER LINE 16 CITY APPROVED BACKFLOW PREVENTOR 17 4" x 8" SANITARY SEWER TEE 18 8" PVC SANITARY SEWER LINE (SEE SHEET C3.0) 19 SANITARY SEWER MANHOLE (SEE SHEET C3.0) 20 20' - 8" PVC SANITARY SEWER STUB @0.40% 21 4" PVC SDR35 SANITARY SEWER SERVICE LINE 22 1500 GALLON TRAFFIC RATED GREASE TRAP 23 4" TRAFFIC RATED CLEAN-OUT RE: ISPWC SD-506A 24 RMP TRANSFORMER RE: ELECTRICAL SITE PLAN 25 UNDERGROUND ELECTRICAL CONDUIT RE: ELECTRICAL SITE PLAN 26 GAS LINE - TRENCH BY SITE CONTRACTOR, GAS LINE AND METER BY IMG. 27 DELIVERY ACCESS RAMP 28 ADA RAMP; RE: B2 / C4.0 29 4" YELLOW PAVEMENT MARKING 30 WHITE PAVEMENT MARKING WHERE SHOWN 31 ADA PARKING PAVEMENT MARKINGS WITH RESERVED PARKING SIGN 32 4' WIDE TRUNCATED DOME PANEL 33 WHITE PAINTED CROSSWALK 34 4" WIDE YELLOW PARKING STRIPE 35 DUMPSTER ENCLOSURE RE: ARCHITECTURAL PLANS 36 PEDESTAL SIGN RE: ELECTRICAL SITE PLAN 37 SITE LIGHTING RE: ELECTRICAL SITE PLAN 38 PRE-SELL BOARD 39 ORDER STATION 40 2" CALIPER DECIDUOUS TREES @ 30' O.C. (5 EACH) 41 TURF SEEDING / SOD 42 LARGE SHRUB / SCREENING SHRUB 43 SMALL SHRUB 44 4" GREASE LINE 45 4" WASTE LINE 46 8" THICK CONCRETE PAD 47 FUTURE BEEHIVE CREDIT UNION SERVICE LINES 48 SNOW STORAGE 49 SAFETY RAILING RE: 9/C5.3 50 STEEL BOLLARDS RE: 12/C5.3 # SITE/UTILITY PLAN 01 02 03 0405 06 07 08 10 09 11 12 13 14 15 17 18 18 19 19 19 20 20 21 22 23 24 25 26 27 28 08 2930 31 32 33 34 29 2929 34 35 36 37 38 38 39 39 40 41 41 42 42 43 43 43 43 44 45 46 47 SITE INFORMATION SNOW STORAGE SURFACE AREA - 14,350 SQ. FT. STORAGE AREA REQUIRED - 1,435 SQ. FT. STORAGE AREA PROVIDED - 2,492 SQ. FT. SNOW STORAGE FOR PRIVATE ROAD WILL BE ALONG THE EAST AND SOUTH SIDE RESPECTIVELY LANDSCAPE LOT AREA - 29,666 SQ. FT. LANDSCAPE REQUIRED - 2,967 SQ. FT. (10%) LANDSCAPE PROVIDED - 5,020 SQ. FT. 48 48 48 48 48 48 49 50 50 How is this accessed? DEQ Approval required. Water rights transferred to City. Streetlight required. Location to be determined. Gates must open 180 degrees. Right side pickup. Sidewalk must be completed to 2nd East. Will stubs be capped? Owner to make sure parking stalls are empty on pickup day. 4860 4870 4880 4860 4870 4880 4850 4850 SEAL DESCRIPTIONDATEREV. ISSUE DATE: **/**/**** PROJECT NUMBER: 21-008 DRAWN BY: CHECKED BY: SHEET NAME SHEET NUMBER MO O D Y R D & N 2 N D E RE X B U R G , I D 8 3 4 4 0 PROJECT TYPE: SITE NUMBER: BUILDING TYPE: OWNER: BASE VERSION: DRAWING RELEASE: PROJECT YEAR: ASSET TYPE: CLASSIFICATION: UPGRADE CLASSIFICATION: DESIGN TYPE: #13487 (2.0) SMART 40+ FREESTANDING NEW FRANCHISE 2020 NEW BUILD 2021 (2.0) UM BRITE SUMMER NEW SMART 40+ GREBEIFRFF J E E R E E N I G NEONALSI E S ROF P  PRIVATE DRIVE PROFILE 01 STANDARD MANHOLE TYPE A RE: ISPWC SD 501 02 8" PVC SDR35 SANITARY SEWER MAIN LINE 03 CONNECT EXISTING SEWER LINE TO NEW MANHOLE 04 8" CLASS 50 DUCTILE IRON WATER LINE (6' MIN. BURY) 05 GATE VALVE (SEE SHT. C1.0 FOR OTHER LOCATIONS) 06 16" x 8" HOT TAP WITH 8" GATE VALVE 07 CAP WITH THRUST BLOCK # 01 0101 01 02 03 04 05 06 07 What are inverts South and east?