HomeMy WebLinkAboutARCHITECTURAL PLANS 2 - 21-00694 - 240 E Moody - Wendy's - New BuildingGENERAL NOTES
A. PAY ALL FEES AND ARRANGE FOR EXECUTION OF ALL TAPS, METERS WITH REQUIRED
ENCLOSURES (IF ANY), AND APPURTENANCES INHERENT TO THE INSTALLATION OF PLUMBING
SERVICE.
B. PROVIDE ALL LABOR, EQUIPMENT, AND MATERIALS NECESSARY TO EXECUTE THE PLUMBING
WORK INDICATED ON THE DRAWINGS AS SPECIFIED, AND AS REQUIRED BY LOCAL CODES AND
ORDINANCES. PLUMBING WORK SHALL INCLUDE ALL PIPING FOR DOMESTIC HOT AND COLD
WATER LINES, VENT AND SANITARY LINES, HOOK-UP OF ALL FIXTURES SCHEDULED ON THE
DRAWINGS, AND INSULATION OF DESIGNATED PIPING. WORK SHALL ALSO INCLUDE ALL GAS
PIPING AND EQUIPMENT CONNECTIONS WHERE REQUIRED. INCLUDE ALL ITEMS SUCH AS
FITTINGS NOT MENTIONED BUT UNDERSTOOD TO BE NECESSARY TO COMPLETE THE
PLUMBING SYSTEM. COORDINATE ALL WORK WITH OTHER CONTRACTORS.
C. PROVIDE FOR DRAINING WATER SYSTEM AND CAP ALL STUBS UNTIL FINISH WORK IS
INSTALLED. INSTALL DRAIN VALVE AT WATER METER WITH 3/4" HOSE THREAD AND VACUUM
BREAKER.
D. PROVIDE VALVES ON WATER SUPPLIES TO EACH FIXTURE & EQUIPMENT. VALVES SHALL BE 1/4
TURN SHUT-OFF VALVES.
E. INSULATE ALL PIPING PER SPECIFICATIONS.
F. PLUMBING FIXTURES SHALL BE PROVIDED WHERE SHOWN ON DRAWINGS. FIXTURE FITTINGS
AND EXPOSED FIXTURE PIPING SHALL BE BRASS CHROMIUM PLATED. TRAPS SHALL BE CAST
BRASS. FIXTURES SHALL BE EQUAL IN ALL RESPECTS TO FIXTURES SPECIFIED.
G. PROVIDE ROUGH-IN AND FINAL CONNECTIONS OF REQUIRED WASTE, VENT, AND WATER
SUPPLY PIPING.
H. THIS CONTRACTOR SHALL GUARANTEE ALL WORK INSTALLED UNDER THE CONTRACT TO BE
FREE FROM DEFECTIVE WORKMANSHIP AND MATERIALS, (USUAL WEAR IS EXPECTED), AND
SHOULD DEFECTS DEVELOP WITHIN A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF THE
BUILDING BY THE OWNER, THIS CONTRACTOR SHALL REPAIR AND/OR REPLACE DEFECTIVE
ITEMS AND ALL DAMAGE RESULTING FROM FAILURE OF THESE ITEMS, AT NO EXPENSE
WHATSOEVER TO THE OWNER
I. THE DIRECTION OF THE SANITARY MAIN AND THE LOCATION OF THE GREASE INTERCEPTOR
SHALL BE COORDINATED WITH CIVIL DRAWINGS PRIOR TO ROUGH-IN.
J. PROVIDE PROVENT TRAP GUARD (OR APPROVED EQUAL) AT ALL FLOOR DRAINS. PROVIDE
TRAP PRIMERS ON FLOOR DRAINS ONLY IF REQUIRED BY AUTHORITY HAVING JURISDICTION
(AHJ). IF AHJ REQUIRES TRAP PRIMERS, LAYOUT DISTRIBUTION TO CONNECT MULTIPLE FLOOR
DRAINS TO ONE TRAP PRIMER.
K. COORDINATE LOCATION AND ROUGH-IN HEIGHT OF KITCHEN EQUIPMENT WITH OWNER AND
MILLWORK PRIOR TO ROUGH-IN.
L. PROVIDE WATER HAMMER ARRESTORS AT END RUN OF ALL WATER PIPING. SIZE AND LOCATE
AS RECOMMENDED BY PLUMBING AND DRAINAGE INSTITUTE STANDARD PDI-WH201, AND AS
RECOMMENDED BY THE MANUFACTURER.
M. ALL PIPING (GAS AND WATER) SHALL BE CONCEALED IN WALL SPACE WHEN POSSIBLE,
UNLESS NOTED OTHERWISE.
N. DAMAGES TO EXISTING WALLS, FLOORS, FINISHES ETC. BY THIS CONTRACTOR SHALL BE
REPAIRED AT THIS CONTRACTOR'S EXPENSE.
O. WATER HEATER, WATER METER AND BACKFLOW PREVENTER SHALL BE INSTALLED TO MEET
ALL STATE, COUNTY AND LOCAL JURISDICTION CODES.
P. ON ALL SYNFLEX LINE INSTALLATIONS (EXCEPT DRINK STATIONS AND COFFEE BREWER)
TRANSITION TO COPPER AT TOP OF WALL, AND ROUTE DOWN INSIDE WALL AND THEN
THROUGH WALL TO EXPOSED SHUT OFF VALVE. DRINK STATIONS WILL HAVE SYNFLEX LINES
FROM FILTER TO UNIT INSTALLED BY BEVERAGE SYSTEM INSTALLER.
Q. 3 COMP SINK, COMBI OVEN AND 2 AREA FLOOR DRAINS BETWEEN HOOD AREA SHALL BE
ROUTED TO GREASE WASTE LINE. ALL OTHER DRAINS SHALL BE ROUTED TO BUILDING
SANITARY.
R. ALL WATER SUPPLY LINES, VENT STACK LINES, SANITARY LINES, AND OTHER EXPOSED
PLUMBING LINES SHALL BE COMPLETELY SEALED AT ALL WALL PENETRATIONS. PROVIDE
CHROME ESCUTCHEON PLATE SEALED TO WALL WITH SILICONE SEALANT.
S. SEE CONNECTION SCHEDULE FOR ALL INDIVIDUAL PIPE SIZES.
WATER CALCULATION
CRITICAL ELEVATIONS AND DISTANCES: FEET
ELEVATION OF CONTROLLING FIXTURE (WATER CLOSET)4.0
ELEVATION OF FINISHED FLOOR 0.0
ELEVATION OF WATER MAIN -4.0
ELEVATION OF WATER ENTRY -4.0
VERTICAL DIST. FROM WATER MAIN TO CONTROLLING FIXTURE 8.0
SYSTEM PRESSURE REQUIREMENTS:PSI
ELEVATION (VERTICAL DISTANCE) X 0.434 PSI/FT 3.5
PRESSURE NEEDED AT CONTROLLING FIXTURE 20.0
BACKFLOW PREVENTER: 1-1/2" AT 66 GPM 8.0
WATER METER: 1-1/2" AT 66 GPM 10.0
TOTAL 41.5
PIPE RUNS:FEET
EXTERIOR, MAIN TO BUILDING ENTRY 100.0
EXTERIOR, VERTICAL RISE 0.0
INTERIOR, ENTRY TO CONTROLLING FIXTURE 60.0
INTERIOR, VERTICAL RISE 8.0
ALLOWANCE FOR FITTINGS, ETC. (LENGTH X 0.25)42.0
TOTAL 210.0
SYSTEM PRESSURE DATA: PSI
STREET PRESSURE 80.0
SYSTEM PRESSURE REQUIRED 41.5
PRESSURE AVAILABLE FOR (PIPING) FRICTION LOSS 38.5
PIPE SIZING:PSI/100'
PRESSURE AVAILABLE X 100 / (TOTAL PIPE RUN)18.3
* NOTE: ALL PIPING IS SIZED FOR 5 PSI/100' PRESSURE LOSS
REFER TO WENDY'S CONSOLIDATOR LIST
TO OBTAIN BUILDING MATERIAL QUOTES.
REFER TO WENDY'S APPROVED SUPPLIER
LIST FOR PHONE NUMBERS AND CONTACTS.
ATTENTION ALL BIDDERS
REMARKS (#)
FIXTURE & EQUIPMENT CONNECTION SCHEDULE
SY
M
B
O
L
QU
A
N
T
I
T
Y
GENERAL FIXTURE DESCRIPTION
DOMESTIC WATER SANITARY
NATURAL
GAS
US
E
D
C
O
O
K
I
N
G
O
I
L
REMARKS (#)
FI
L
T
E
R
E
D
W
A
T
E
R
-
F
C
W
1
FI
L
T
E
R
E
D
W
A
T
E
R
-
F
C
W
2
FI
L
T
E
R
E
D
W
A
T
E
R
-
F
C
W
3
FI
L
T
E
R
E
D
W
A
T
E
R
-
F
C
W
4
CO
L
D
W
A
T
E
R
HO
T
W
A
T
E
R
(
1
4
0
°
)
HO
T
W
A
T
E
R
(
1
1
0
°
)
MO
U
N
T
I
N
G
H
E
I
G
H
T
DR
A
I
N
L
I
N
E
S
I
Z
E
TR
A
P
FI
X
T
U
R
E
D
R
A
I
N
DI
R
E
C
T
/
I
N
D
I
R
E
C
T
(
D
/
I
)
SA
N
I
T
A
R
Y
/
G
R
E
A
S
E
(
S
/
G
)
VE
N
T
MO
U
N
T
I
N
G
H
E
I
G
H
T
CO
N
N
E
C
T
I
O
N
S
I
Z
E
BT
U
L
O
A
D
PLUMBING FIXTURES
WC 2 WATER CLOSET (ACCESSIBLE)114"(1)4" INT 4" D S 2" FL
(3), (6)
LAV-1 2 LAVATORY
12"12"(1)112"112"112"D S1
12"(1) (3), (6)
LAV-2 1 LAVATORY 12"12"(1)112"112"112"D S1
12"(1) (3), (6)
FPWH 2 FROST PROOF WALL HYDRANT
3 4"18"(3), (6)
PLUMBING DRAINS
FD 11 FLOOR DRAIN 3" 3" * 1
12"FL (3), (8), (9)
FS-1 4 FLOOR SINK 3" 3" * 1
12"FL (3), (8), (9)
FS-2 1 FLOOR SINK 3" 3"*112"FL (3), (8), (9)
HD 1 HUB DRAIN 3" 3" * 1
12" 12"
(3), (8), (9)
KITCHEN EQUIPMENT - FRONT COUNTER
E2302 1 BACK COUNTER HAND SINK
12"12" 14" 2" 1
12"112"D S1
12" 12"
(4), (6), (8), (9)
KITCHEN EQUIPMENT - BEVERAGE LINE
A0105 1
BEVERAGE SYSTEM (DRIVE-THRU)12"14"IS (4), (14), (15)
A0608 1 COFFEE BREWER
12"14"(4), (10), (11)
E4006 1 DRIVE-THRU HAND SINK ASSEMBLY 12"12"14" 2"112"112"D S1
12"(4), (8), (9)
KITCHEN EQUIPMENT - FRYLINE
K1401 1 COMBI OVEN 12"12" 30" 3" 3" I G 1
12"(5), (10), (11)
KITCHEN EQUIPMENT - PREP AREA / WAREWASH
A0801 1 TEA BREWER *
12"72"(4), (10), (11)
T1213 1 CHEMICAL BLEND STATION (FOR
T2011)12"12"54"(4)
T0902 1 1 COMP PREP SINK
12"12"14"(4), (6), (7), (8),
(9)
T2011 1 3 COMP SINK
12"12"14"(4), (6), (7), (8),
(9)
T2061 1 WAREWASH MACHINE
12"3 4"61.75" 3" 3"2" I G 1
12"(4), (6), (7), (8),
(9), (10)
KITCHEN EQUIPMENT - HAND SINK
T2703 1 HAND SINK
12"12" 14" 2" 1
12"112"D S1
12" 12"
(4), (6), (8), (9)
KITCHEN EQUIPMENT - DRINK EQUIPMENT
QP0909 1 ICE MAKER - KITCHEN
12" 72" 3" 3"
3 4"I S1
12"(4), (6), (7),
(10)
T2212 1 WATER TREATMENT UNIT
3 4"85"(4), (11), (13)
KITCHEN EQUIPMENT - MOP SINK / CLEANING EQUIPMENT
T0303 1
MOP SINK FAUCET (FOR T0602 -
LOWER)12"12"36"(4), (6)
T0304 1
MOP SINK FAUCET (FOR T0602 -
UPPER BLEND CENTER)12"12"54"(4), (6)
T0602 1 MOP SINK 3" 3" 3" D S 1
12"FL (4), (6)
T1212 1 CHEMICAL BLEND CENTER
12"12"54"(4)
T2213 1 REVERSE OSMOSIS SYSTEM
12"12"85"(5)
A0304 1 BAG-IN-BOX
12"85"(5), (11), (12)
KITCHEN EQUIPMENT - DRINK STAND
A0202 2 BEVERAGE SYSTEM (SELF-SERVE -
DINING ROOM)12"14"IS (4), (14), (15)
QP0222 2 ICE MAKER (CUBER) - DINING ROOM 12" 96" 3" 3"
3 4"I S1
12"(4), (6), (7),
(10)
*VERIFY QUANTITIES WITH ARCHITECTURAL EQUIPMENT PLAN AND SCHEDULE.*
1. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.
2. PLUMBING FIXTURE PROVIDED BY PLUMBING INSTALLER.
REFER TO PLUMBING FIXTURE SCHEDULE
3. EQUIPMENT FURNISHED BY OTHERS.
4. PLUMBING INSTALLER TO MAKE FINAL CONNECTIONS TO
EQUIPMENT.
5. FINAL CONNECTION TO EQUIPMENT BY OTHERS.
6. PROVIDE VALVE AT EACH CONNECTION TO EQUIPMENT.
7. PLUMBING CONTRACTOR TO PROVIDE INDIRECT DRAIN TO
FLOOR DRAIN OR SINK.
8. VERIFY DIRECT OR INDIRECT WASTE CONNECTION PER
LOCAL CODE REQUIREMENTS.
9. VERIFY SANITARY OR GREASE WASTE CONNECTION PER
LOCAL CODE REQUIREMENTS.
10. SHUTOFF VALVE AND FLEX CONNECTOR LINES TO
PRE-RINSE ARE PROVIDED WITH FIXTURE.
11. PROVIDE WITH BACKFLOW PROTECTION PER BACKFLOW
PREVENTOR SCHEDULE. COORDINATE BACKFLOW
INSTALLATION WITH KITCHEN EQUIPMENT PROVIDER AND
BEVERAGE INSTALLER.
12. PROVIDE WITH WATTS NO. SS009 BACKFLOW PREVENTER
WHEN LOCAL JURISDICTION REQUIRES A HIGHER LEVEL OF
PROTECTION THAN PROVIDED BY THE INTEGRAL ASSE 1022
DOUBLE CHECK VALVE.
13. PLUMBING INSTALLER TO RUN WATER LINE TO FILTRATION
SYSTEM WITH FINAL CONNECTIONS BY BEVERAGE
INSTALLER.
14. BEVERAGE INSTALLER TO ROUTE LINE TO POINT OF USE
AND PLUMBING INSTALLER TO MAKE FINAL CONNECTION.
15. WATER SUPPLY LINE IS PART OF THE BEVERAGE BUNDLE.
PUMP SCHEDULE
SYMBOL MANUF. MODEL GPM
HEAD
(FT)VPHA W
NOTES
(#)
RCP GRUNDFOS ALPHA2 5 12 115 1 0.65 5 - 65
(1)
NOTES:
1.RECIRCULATING PUMP: BRONZE BODY RECIRCULATING PUMP WITH "AUTOADAPT" VARIABLE
SPEED MOTOR, INSTALL NEAR WATER HEATER PER MANUFACTURER'S INSTRUCTIONS. PROVIDE
WITH ALPHA 3-PRONG PLUG AND COORDINATE CONNECTION WITH ELECTRICAL CONTRACTOR.
PROVIDE WITH HONEYWELL L6006C SURFACE MOUNT AQUASTAT SET TO 5°F BELOW WATER
HEATER OPERATING TEMPERATURE.
WSFU CALCULATIONS
FIXTURE QTY.WSFU TOTAL
WATER CLOSET (FLUSH)21020
LAVATORY 3 2 6
MOP BASIN 1 33
HAND SINK 3 2 6
1-COMP SINK 1 4 4
3-COMP SINK 1 44
WAREWASH 1 3 3
BEVERAGE STATION 3 1 3
BAG-N-BOX 1 33
ICE MAKER 3 1 3
COMBI-OVEN 1 1 1
COFFEE BREWER 1 0.5 0.5
TEA BREWER 1 0.5 0.5
HOSE BIBB 2 36.0
*WSFU VALUES GIVEN PER IPC* WSFU TOTAL 63.00
DFU CALCULATIONS
FIXTURE QTY.DFU TOTAL
WATER CLOSET (FLUSH)248
LAVATORY 3 1 3
MOP BASIN 1 2 2
HAND SINK 3 1 3
3" HUB DRAIN 1 5 5
3" FLOOR SINK 7 5 35
3" FLOOR DRAIN
(EMERGENCY)9--
*DFU VALUES GIVEN PER IPC* DFU TOTAL 56.0
EXPANSION TANK SCHEDULE
SYMBOL MANUF.MODEL GAL.
ACCEPT.
GAL.
CONN.
LOC.
CONN.
SIZE MOUNTING NOTES
(#)
ET-1 AMTROL ST-8 4.4 3.2 TOP
3 4"ABOVE WH-1 (1), (2)
NOTES:
1.EXPANSION TANK: STEEL SHELL, HEAVY DUTY BUTYL NSF/ANSI 61, FACTORY PRECHARGED TO
50 PSIG. MAX OPERATING TEMPERATURE 200°, MAX OPERATING PRESSURE 150 PSI, 1 YEAR
MANUFACTURER'S WARRANTY. INSTALL PER MANUFACTURER'S INSTRUCTIONS.
2.FIELD CHARGE EXPANSION TANK TO SYSTEM PRESSURE BEFORE CONNECTION TO DOMESTIC
WATER SYSTEM. FIELD VERIFY PRESSURE REQUIREMENTS.
GREASE INTERCEPTOR SIZING
FIXTURE QTY.FLOW RATE
(2 MIN)
FLOW RATE
(1 MIN)
FLOOR DRAIN 3 0.00 0.00
FLOOR SINK 8 0.00 0.00
MOP BASIN 1 9.35 18.70
THREE COMP SINK 1 30.00 60.00
DISHWASHER 1 5.00 10.00
TOTAL FIXTURE FLOW RATE 44.35
CALCULATED FLOW
RATE
(GPM)
PIPE SIZE FLOW RATE (4 IN)75 44.35
[(CU IN / 231) = GAL X 0.75 / 2 MIN = 2 MIN FLOW RATE]
NUMBER OF SEATS 55
GREASE PRODUCTION
(LBS OF FOG)
AVG. MEALS PER SEAT PER DAY 4 693.0
FAST FOOD - FULL PREP
(HIGH / NO FLATWARE: 0.035 LBS PER SERVING)0.035
DAYS BETWEEN PUMP OUTS 90
[SERVINGS PER DAY X GREASE PRODUCTION VALUE X DAYS BETWEEN PUMP-OUTS = GREASE
OUTPUT]
BACKFLOW PREVENTER SCHEDULE
LOCATION TAG MODEL ASSE
MAIN WATER SUPPLY RPZ WATTS LF009-QT-S 1013
CARBONATOR DCV-1 WATTS SD-3 1022
SODA DISPENSORS DCV-2 WATTS SD-2 1022
OTHER EQUIPMENT DCV-3 WATTS SERIES 7 1024
NOTE:
VERIFY BACKFLOW VALVE REQUIREMENTS AND APPROVAL FOR ALL EQUIPMENT WITH AUTHORITIES
HAVING JURISDICTION PRIOR TO INSTALLATION.
GAS FIRED WATER HEATER SCHEDULE
SYMBOL MANUF. MODEL GAL. BTU
GAS
PRESSURE
RECOVERY
(GPH/100°F)
SET POINT
(°F)
NOTES
(#)
WH-1 BRAFDORD
WHITE
EF-100T-1
99E-3N 100 199,999 7" W.C. 235 140
(1), (2)
NOTES:
1.GAS FIRED WATER HEATER: THREE YEAR TANK/PARTS WARRANTY, GLASS LINED STEEL TANK,
150 PSI WORKING PRESSURE, THERMAL EFFICIENCY OF 97% MEETING CURRENT EDITION OF
ASHRAE 90.1B AND LOCAL ENERGY CONSERVATION REQUIREMENTS. PROVIDE T&P RELIEF
VALVE.
2.FURNISH WITH EXPANSION TANK AS SPECIFIED ON PLANS.
BV BALL VALVE
GW
D
G
UCO
FW
SANITARY WASTE (SAN) - BELOW SLAB/GRADE
PLUMBING VENT (V) - BELOW SLAB/GRADE
GREASE WASTE (GW) - BELOW SLAB/GRADE
USED COOKING OIL (UCO)
PLUMBING VENT (V)
CONDENSATE LINE (D)
HOT WATER RETURN (HWR) 140°, 120°
GAS LINE (G)
NSF 61 TUBING (NSF) [BY OTHERS]
FILTERED WATER SUPPLY (FW)
HOT WATER (HW) 140°, 120°
COLD WATER (CW) - BELOW SLAB/GRADE
COLD WATER (CW)
NSF
BFP
RI
BACKFLOW PREVENTER
ROUGH-IN
AFF/AFG
FCO/ECO
VTR
IW
WCO/CO
ABOVE FINISHED FLOOR/GRADE
FLOOR/EXTERIOR CLEANOUT
WALL CLEANOUT/ CLEANOUT
VENT THRU ROOF
INDIRECT WASTE
TYPICALTYP
AHJ
UNO
AUTHORITY HAVING JURISDICTION
UNLESS NOTED OTHERWISE
ABBREVIATIONS: LINETYPES:
END CAP
SHUTOFF VALVE (BALL TYPE)
TEE TURNING UP/DOWN
PIPE TURNING UP/DOWN
CHECK VALVE
BALANCING VALVE
PIPE SYMBOLS:
WALL HYDRANT
RO REVERSE OSMOSIS WATER SUPPLY (RO)
*NOT ALL SYMBOLS OR LINETYPES ARE NECESSARILY USED*PLUMBING SYMBOLS LEGEND
GREASE INTERCEPTOR SCHEDULE
SYMBOL MANUF. MODEL
FLOW RATE
(GPM)
GREASE
CAPACITY (LBS.)
LIQUID CAPACITY
(GAL.)NOTES (#)
GI SCHIER GB-250 100
1,895 277 (1), (2), (3)
NOTES:
1. CONTRACTOR SHALL SUBMIT PROPOSED GREASE INTERCEPTOR INSTALLATION PLANS AND
SPECIFICATIONS TO LOCAL AUTHORITIES FOR THEIR APPROVAL BEFORE ACQUISITION. SEE
MANUFACTURER INSTALLATION MANUAL FOR ADDITIONAL INSTRUCTIONS.
2.PROVIDE WITH C24HP H20 LOAD RATED PICKABLE CAST IRON LIDS WITH "SAFE MANWAY" FALL
PROTECTION COVER.
3. PROVIDE WITH AK1 ANCHOR KIT.
PLUMBING FIXTURE SCHEDULE
SYMBOL FIXTURE TYPE MANUF.MODEL DESCRIPTION ACCESSORIES/OPTIONS
NOTES (#)
WC WATER CLOSET
(ACCESSIBLE)SLOAN ST-2029
(2102029)
FLOOR MOUNT, WHITE VITREOUS CHINA, 1.1-1.6 GPF
ELONGATED SIPHON JET BOWL, 1-1/2" TOP SPUD, & RIM
HEIGHT 17" A.F.F.
TOTO #TMT1LN32#CP 1.28 GPF MANUAL WATER CLOSET
FLUSH VALVE. MAINLINE #ML1055SSC00 WHITE OPEN FRONT
ELONGATED TOILET SEAT LESS COVER.
(1), (4)
LAV-1 LAVATORY
(ACCESSIBLE)
AMERICAN
STANDARD
#0356.421.020
LUCERNE WALL HUNG, 2012"x1814", WHITE VITREOUS CHINA.TOTO #TL210DD12#CP POLISHED CHROME, LAVATORY
FAUCET, 1.2 GPM FLOW RATE (1), (2), (3), (4)
LAV-2 LAVATORY
(ACCESSIBLE)DURAVIT
D17511
(#0454120060)
VERO
WALL HUNG WASHBASIN, 4714"x1812", WHITE VITREOUS
CHINA,WITH CHROME METAL CONSOLE AND NO FAUCET
HOLES, SINGLE HOLE FOR FAUCET, & BACK OVERFLOW.
ROHL A1423LMAPC-2 "ACQUI WALL MOUNT BRIDGE
FAUCET", POLISHED CHROME, 8" WALL MOUNT, 10" SWIVEL
SPOUT, 1.2 GPM AERATOR. PROVIDE WITH CROW WORKS
27" HIGH GUNMETAL SINK STAND
(1), (2), (4), (5)
WB COMBI OVEN
WATER BOX SIOUX CHIEF 696-G2403WF
WHITE ABS WATER SUPPLY BOX WITH 3/4" HOSE THREAD,
AND PEX-A F1960 CONENCTIONS.INSTALL PER "COMBI OVEN SUPPLY BOX ROUGH-IN" DETIAL.
FPWH FROST PROOF
WALL HYDRANT WOODFORD MODEL 65
ANTI-SIPHON, AUTOMATIC DRAINING, WALL HYDRANT,
NON-FREEZE INTEGRAL VACUUM BREAKER, ALL BRONZE
INTERIOR PARTS, KEY OPERATED, 3/4" SOLDER INLET.
MOUNT 18" ABOVE FINISHED GRADE. PROVIDE
APPROPRIATE MODEL FOR WALL THICKNESS AND SITE
SPECIFIC TEMPERATURE REQUIREMENTS.
(4)
FD FLOOR DRAIN SIOUX CHIEF /
ZURN
832-35D-NR /
#ZN415-B-3NH
FLOOR DRAIN WITH 5" ROUND NICKEL BRONZE ADJUSTABLE
STRAINER AND CAST IRON BODY & 3" BOTTOM OUTLET.
PROVIDE WITH ASSE 1072 APPROVED TRAP SEAL DEVICE.
TRAP SEAL DEVICE SHALL BE TRAP PROSET TRAPGUARD
OR APPROVED EQUAL. INSTALL PER MANUFACTURER'S
RECOMMENDATIONS. PROVIDE DRAINS IN CUSTOMER
AREAS WITH VANDAL RESISTANT SCREWS.
(4)
FS-1 FLOOR SINK SIOUX CHIEF /
ZURN
#861-3PN-D /
#Z1900-3NH-K-4
12" SQUARE TOP FLOOR SINK W/8" DEEP PVC/CAST IRON
BODY & 3" BOTTOM OUTLET (CAST IRON OPTIONAL)(4)
FS-2 FLOOR SINK SIOUX CHIEF /
ZURN
#861-23X-N2 /
#Z1900-3NH-2NB
12" SQUARE TOP FLOOR SINK WITH 6" DEEP ACID
RESISTANT ENAMEL CAST IRON BODY AND 3"OUTLET WITH
12 NICKEL BRONZE GRATE.
SET FLOOR SINK LEVEL WITH FINISH FLOOR.(4)
HD HUB DRAIN N/A N/A
STUB 3" WASTE LINE 12" ABOVE FINISHED FLOOR SLAB FOR
FUTURE CONNECTIONS BY OTHERS.
PROVIDE WITH ASSE 1072 APPROVED TRAP SEAL DEVICE.
TRAP SEAL DEVICE SHALL BE TRAP PROSET TRAPGUARD
OR APPROVED EQUAL. INSTALL PER MANUFACTURER'S
RECOMMENDATIONS.
(4)
MV MIXING VALVE ZURN
ZW3870XLT /
ZW1070XL
THERMOSTATIC CONTROLLER WITH INTEGRAL CHECKS, ALL
BRASS BODY WITH DUAL STAINLESS STEEL STRAINER,
VANDAL RESISTANT TEMPERATURE ADJUSTMENT HANDLE.
SET TO 105°F. MOUNT IN ACCESSIBLE LOCATION.(4)
NOTES:
1.INSTALL IN ACCORDANCE TO ADA ACCESSIBILITY REQUIREMENTS.
2.PROVIDE WITH QUARTER TURN BRASS ANGLE COMPRESSION STOPS WITH LOOSE KEY HANDLES, STAINLESS BRAIDED SUPPLIES, CHROME SUPPLY AND DRAIN ESCUTCHEONS, CHROME GRID STRAINER
DRAIN WITH TAILPIECE, CHROME PLATED CAST BODY P-TRAP WITH CLEANOUT. INSULATE WASTE AND WATER PIPING WITH TRUEBRO "LAV-GUARD2" #101-EZ.
3. FURNISH WITH ZURN #Z-1231-81 LAVATORY CARRIER.
4.REFER TO ARCHITECTURAL SUPPLIER PAGE FOR WENDY'S NATIONAL VENDOR PRICING CONTACTS. VERIFY PRIOR TO BID IF GENERAL CONTRACTOR OR OWNER WILL PROVIDE EQUIPMENT.
PLUMBING SCHEDULE
AND NOTES
P1.0
AUTHOR
CHECKER
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
V2201
EX
T
.
R
A
M
P
LCA672LCE6120
SHARED\xUS2.0-P1-1 Base.dwg
1PLUMBING PLAN - SANITARY WASTE & VENT
1/4" = 1'-0"
SEE SITE PLAN FOR
CONTINUATION
GW
UTILITY
116
1
2
3
3
T2061
QP0909
A0105
T2011
T0902
T0602
T0802
T2703
E2302
ECO
4"
ECO
FD
FCO
FD
4"
4"
3"
4"
3"
2"
FCO
FD
2
4"
4"
4"
3"
4"
FS-1
FD
FD
FCO
3
FD
WCO
3"
4"4"3"
3"
3"
3"
3"
3"
4"
2"2"
GW
GW
GW
4"
4"
4"
3"
3"
UC
O
3 4"
6
INSTALL USED OIL
SYSTEM PER VENDOR
INSTRUCTIONS.WC
WC
LAV-1
LAV-1
3
3"3"
3"
4"4"4"
3"
2"2"
2"
3"
112"
2"
2"
112"
112"
112"2"
WCO
WCO
FS-1 FS-1
WH-18
4"
QP0222
FS-1
FCO
3"
GW
9
5
1"
CO
1"
3" HD
4"
3"
A0202
4"
GI
FDFD
3"
K1401 J1004
43"VTR
FD
WC
2"
3"
2"
2"
9
3
3"
3"
4
7
MAINTAIN SEPARATION BETWEEN UCO, SANITARY
LINES, VENT LINES, AND WATER LINES IN THIS
WALL. MAINTAIN SEPARATION BETWEEN THE
USED COOKING OIL LINE, VENT LINES, AND
DOMESTIC WATER LINES. ROUTE HOSE BIBB
BELOW USED COOKING OIL LINE.
3"VTR
3"3"
3 4"
UCO FS-2
#CODED NOTES:
1. EXTEND SANITARY LINE TO MAIN. FIELD VERIFY EXACT LOCATION WITH LOCAL UTILITY
COMPANY PRIOR TO BID.
2. PROVIDE GB-250 KITCHEN GREASE INTERCEPTOR. LOCATE CLEAR OF DRIVE-THRU LANE.
REFER TO CIVIL DRAWINGS FOR FINAL LOCATION. REFER TO "GREASE INTERCEPTOR" DETAIL.
3. VENT RISER FROM UNDER FLOOR PIPING. REFER TO SANITARY ISOMETRIC FOR
CONTINUATION.
4. PROVIDE SANITARY VENT THROUGH ROOF PER "VENT THRU ROOF (VTR)" DETAIL. LOCATE
VENT MINIMUM OF 10'-0" AWAY FROM AIR INTAKES ON ROOF, UNLESS APPROVED BY ENGINEER
PRIOR TO INSTALLATION. VTR SHALL BE EXTENDED HIGHER THAN ANY AIR INTAKES. LOCATE
PER ROOF PLAN.
5. ROUTE CONDENSATE FROM FREEZER/COOLER TO FLOOR DRAIN. PROVIDE RAYCHEM
GUARDIAN GM-51-IM HEAT TRACED LINE FROM INSIDE OF COOLER TO FLOOR DRAIN.
(COORDINATE POWER FOR HEAT TRACE WITH ELECTRICAL PLANS.) REFER TO
"COOLER/FREEZER CONDENSATE" DETAIL.
6. ROUTE USED COOKING OIL LINE BEHIND EQUIPMENT. EXTEND LINE TO USED COOKING OIL
TANK AS SHOWN. REFER TO "USED OIL RECOVERY" DETAIL.
7. ROUTE USED COOKING OIL LINE MINIMUM OF 6" ABOVE CEILING FROM EQUIPMENT TO
RECOVERY TANK AS SHOWN PER PLAN. SLOPE PIPING TO BACK OF BUILDING. REFER TO
INSTALLATION MANUAL FOR EXACT PITCH. LINE CANNOT HAVE ANY TRAPS. USE ONLY BACK
TO BACK 45 DEGREE ELBOW TO CHANGE DIRECTION.
8. PROVIDE THREADED BLACK IRON PIPE DOWN WALL. COVER UCO LINE FROM WALL ENTRY TO
POINT OF CONNECTION AT TANK WITH 1" THICK FIBERGLASS PIPE INSULATION WITH ASJ.
PROVIDE EXTERIOR PIPE INSULATION WITH STAINLESS STEEL PIPE COVER THAT IS BANDED
AND SEALED THROUGHOUT WITH CLEAR UV RESISTANT SILICONE CAULK. PROVIDE WALL
PENETRATOIN WITH STAINLESS STEEL ESCUTCHEON. DO NOT RUN PIPE THROUGH
REFRIGERATED BOXES OR SERVICES SPACES. TURN INTO TANK SHED AT 89" A.F.F. STUB OUT
EXTERIOR SIDE OF WALL.
9. EMERGENCY DRAIN IN RESTROOM SHALL BE INSTALLED FLUSH TO GRADE WITH NO SLOPE.
COORDINATE INSTALLATION HEIGHT WITH GENERAL CONTRACTOR TO ENSURE PROPER
INSTALLATION.
2-WAY
GCO
2-WAY
GCO
VENT PIPING
BELOW GRADE
5'-0"
5'-0"
FD
D
VENT PIPING
BELOW GRADE
FCO
3"
1"
2"
WCO
LAV-2
VENT PIPING
BELOW GRADE
WCO
QP0222
PLUMBING PLAN -
SANITARY WASTE & VENT
P1.1
AUTHOR
CHECKER
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
1
13
13
2
2
8
66
K1401
QP0909
T0602
A0304
A0801
A0105
T0902T2011
FCW-3
1/2" CW, 1/2" HW, AND (2) 1/2" FW DROP DOWN
IN WALL AND EXTEND THRU MILLWORK TO
E4003, A0608, A0105, A0202, & (2) QP0222.
FIELD VERIFY ROUTING.
FCW-3
FCW-4
FCW-1
FCW-2
FCW-3
FPWH
FPWH
E2302
5
5
T0802
1PLUMBING PLAN - DOMESTIC WATER
1/4" = 1'-0"
WC
LAV-1
LAV-1
WC
4
4
4
MV
MV
MV
MV
RCP
T0303
T0304
WH-1
1"
112"112"
112"
112"112"
112"
12"
12"
12"
3 4"
3 4"
3 4"
1"
1"
1"
12"12"
T2213
4
T1213
ET-1
2
3
1 T2061
3 4"
1"
1"
1"
FW
RO
WB
FW
RO
FW RO
MAINTAIN SEPARATION BETWEEN UCO, SANITARY
LINES, VENT LINES, AND WATER LINES IN THIS
WALL. MAINTAIN SEPARATION BETWEEN THE
USED COOKING OIL LINE, VENT LINES, AND
DOMESTIC WATER LINES. ROUTE HOSE BIBB
BELOW USED COOKING OIL LINE.
BEVERAGE EQUIPMENT NOTES
1. BEVERAGE EQUIPMENT SUPPLIER TO RUN NSF 61 TUBING FOR SODA DISPENSOR(S) AND SELF
SERVE ICE MAKER(S).
2. GC, OR PLUMBING CONTRACTOR, TO MAKE FINAL CONNECTIONS FOR ICE MAKER(S).
2. GC, OR PLUMBING CONTRACTOR, TO PROVIDE OETIKER CLAMPS FOR CONNECTING
BEVERAGE HOSES.
3. BEVERAGE EQUIPMENT SUPPLIER TO INSTALL SODA DISPENSERS AND ANCILLARY
EQUIPMENT INCLUDING RACK, WATER BOOSTER, ETC.
4. BEVERAGE EQUIPMENT SUPPLIER TO INSTALL STAINLESS STEEL CHASE COVERS FOR NSF 61
TUBING.
5. BEVERAGE EQUIPMENT SUPPLIER TO CLEAN, SEAL, AND CAP CHASE.
6. BEVERAGE EQUIPMENT SUPPLIER TO INSTALL STAINLESS STEEL CHASE COVERS FOR NSF 61
TUBING.
#CODED NOTES:
1. CHEMICAL FEED UNITS AND INSTALLATION KITS SUPPLIED BY OWNER'S REPRESENTATIVE AND
INSTALLED BY CONTRACTOR. FEED STATION LOCATIONS ARE TO BE VERIFIED WITH OWNER.
PROVIDE BACKFLOW PROTECTION AS REQUIRED BY LOCAL CODE AND PER BACKFLOW
PREVENTER SCHEDULE. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
2. PLUMBING CONTRACTOR TO PROVIDE 1/2" INSULATED COPPER LINES IN WALL WITH BALL VALVE
AT CONNECTION LOCATION AND MALE THREAD ADAPTOR ABOVE CEILING FOR CONNECTION BY
BEVERAGE EQUIPMENT INSTALLER TO NSF 61 TUBING LINES.
3. BEVERAGE EQUIPMENT INSTALLER TO PROVIDE 1/2" NSF 61 TUBING FILTERED COLD WATER LINE
FROM WATER FILTER TO CARBONATOR. BEVERAGE EQUIPMENT INSTALLER SHALL PROVIDE
REQUIRED CODE APPROVED STAINLESS STEEL BACKFLOW PREVENTOR PRIOR TO CARBONATOR
EQUIPMENT. NO COPPER WATER LINES SHALL BE USED FOR CARBONATED WATER LINES AFTER
THE BACKFLOW PREVENTOR.
4. PROVIDE INDIVIDUAL MIXING VALVE FOR ALL HAND SINKS AND LAVATORIES IN AN ACCESSIBLE
LOCATION.
5. ROUTE PEX-A FILTERED AND REVERSE OSMOSIS WATER LINES TO SERVE THE COMBI OVEN.
6. ROUTE 1
14" COLD WATER COPPER LINE FROM ABOVE CEILING DOWN TO APPROXIMATELY 30"+/-
AFF FOR THE WATER CLOSET FLUSH VALVE. SEE RISER DIAGRAMS FOR DETAILS AND
ARCHITECTURAL SHEETS FOR MORE INFORMATION. COORDINATE EXACT LOCATION WITH THE
MANUFACTURER'S EQUIPMENT PRIOR TO ROUGH-IN.
7. EXTEND
3 4" COLD WATER LINE TO WATER FILTRATION SYSTEM IN UTILITY AREA. PROVIDE ALL
CHECK VALVES AND SHUT-OFF VALVES REQUIRED. HOOK UP AND COMMISSION WATER
FILTRATION SYSTEMS, BOOSTER PUMP, AND REVERSE OSMOSIS (RO) SYSTEM PER
MANUFACTURER'S RECOMMENDATIONS. VERIFY ALL RESPONSIBILITIES WITH OWNER AND
PLUMBING FIXTURE SCHEDULE. REFER TO "WATER FILTRATION SYSTEM" DETAIL.
8. DROP 1" HW AND CW AND
12" HWR LINES TO WATER HEATER, EXPANSION TANK, AND
RECIRCULATING PUMP. CONTRACTOR TO FURNISH AND INSTALL WATER HEATER. REFER TO
"LARGE WATER HEATER", "RECIRCULATION PUMP", AND "SMALL EXPANSION TANK" DETAILS.
DISCHARGE T&P RELIEF VALVE AND OVERFLOW TO DRAIN. PROVIDE VALVE AND UNION ON INLET
AND OUTLET. PROVIDE BALANCING VALVES AS REQUIRED FOR RECIRCULATING SYSTEM.
9. BEVERAGE EQUIPMENT SUPPLIER TO RUN 1/2" COLD WATER NSF 61 TUBING LINE ABOVE CEILING
TO DINING ROOM FOR CONNECTION TO BEVERAGE SYSTEM. PROVIDE SHUT OFF VALVES AND
BACK-FLOW PREVENTERS AS REQUIRED TO MAKE FINAL CONNECTION. COORDINATE WITH
OWNER'S REPRESENTATIVE. BEVERAGE BUNDLE WHICH INCLUDES SYRUP AND FILTERED
WATER LINES TO RUN OVERHEAD ABOVE CEILING, EXTEND FROM FILTER SYSTEM AND THRU 6"
ESCUTCHEON PLATE IN CEILING, EXTEND OVERHEAD TO DRINK UNITS THEN DOWN THRU CEILING
AND THROUGH CHASE BEHIND BEVERAGE UNIT. VERIFY RESPONSIBILITIES WITH OWNER AND
FIXTURE SCHEDULE.
10. EXTEND 3/4" HOT AND COLD WATER COPPER LINES DOWN FOR THE MOP SINK/FAUCET FROM
MAIN. MAKE ALL FINAL CONNECTIONS. COORDINATE EXACT LOCATION PRIOR TO ROUGH-IN. MOP
SINK AREA HAS 2 FAUCETS MOUNTED DIRECTLY ABOVE EACH OTHER. REFER TO CONNECTION
SCHEDULE FO0R MOUNTING HEIGHTS. MOP SINK AND HUB DRAIN PROVIDED BY KITCHEN
EQUIPMENT SUPPLIER, SEE ARCHITECTURAL DETAILS. COORDINATE WITH ARCHITECTURAL AND
KITCHEN VENDOR DRAWINGS FOR INSTALLATION INSTRUCTIONS.
11. BEVERAGE EQUIPMENT INSTALLER SHALL PROVIDE NSF 61 TUBING LINES, FOR COLD WATER
SERVING BEVERAGE EQUIPMENT. LINES ARE SHOWN ARE SHOWN FOR REFERENCE ONLY.
COORDINATE WITH OWNER'S REPRESENTATIVE.
12. ROUTE 3/4" HW TO SMALL WATER HEATER SERVING WAREWASH MACHINE. REFER TO "SMALL
WATER HEATER ON PLATFORM" AND "WAREWASH W/ WATER HEATER" DETAILS.
13. EXTEND COPPER PIPING DOWN IN WALL TO FREEZE-PROOF WALL HYDRANT-WOODFORD MODEL
65 OR EQUAL, MOUNT 18" ABOVE FINISHED GRADE. VERIFY EXACT LOCATION WITH
ARCHITECTURAL ELEVATIONS.
14. 1
12" WATER METER AT FLOOR WITH RPZ BACKFLOW PREVENTER, PIPE DISCHARGE TO FLOOR
DRAIN. EXTEND LINE TO MAIN. FIELD VERIFY EXACT LOCATION WITH WATER COMPANY.
15. PROVIDE WATER BOX FOR FILTERED AND REVERSE OSMOSIS WATER LINES SERVING THE COMBI
OVEN PER THE "COMBI OVEN WATER ROUGH-IN" DETAIL.
V2201
EX
T
.
R
A
M
P
LCA672LCE6120
15
15
4 T2703
MV
MV ABOVE
CEILING
LAV-2 4
9
9A0202
QP0222
FCW-3
FCW-1
1"
1"
1"
14
7
11
T2212
T1212
12
9QP0222 FCW-1
WH-2
12
10
PLUMBING PLAN -
DOMESTIC WATER
P1.2
AUTHOR
CHECKER
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
V2201
EX
T
.
R
A
M
P
LCA672LCE6120
SHARED\xUS2.0-P1-3 Base.dwg
1PLUMBING PLAN - NATURAL GAS
1/4" = 1'-0"
1
2WH-1
1
3
3
RTU-2
RTU-1
G G
G
G
2"
114"
1 14"
114"
112"
112"
2WH-1
#CODED NOTES:
1. GAS SERVICE AND METER SETTING SIZED PER GAS COMPANY REQUIREMENTS FOR MAX
CONNECTED LOADS AS SHOWN IN "NATURAL GAS CALCULATIONS" TABLE WITH TOTAL
DEVELOPED LENGTH, INCLUDING FITTINGS, VALVES, ETC. OF 100 LINEAR FEET AND A TOTAL
SYSTEM PRESSURE DROP OF 0.3" W.C. WITH 14" W.C. DELIVERED AT THE METER. HOLD GAS
METER AND NATURAL GAS LINES TIGHT TO BUILDING. REFER TO "GAS SERVICE" DETAIL.
2. ROUTE NATURAL GAS LINE DOWN TO WATER HEATER AS SHOWN PER PLAN. COORDINATE
EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO INSTALLATION. REFER TO
"LARGE WATER HEATER" DETAIL.
3. ROUTE NATURAL GAS UP THROUGH ROOF TO TO ROOFTOP EQUIPMENT AS SHOWN PER PLAN.
COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO INSTALLATION.
REFER TO "ROOFTOP UNIT GAS CONNECTION" DETAIL. GAS LINES ON ROOF ARE TO BE
PAINTED SAFETY YELLOW. GAS LINES MUST BE ROUTED TO ALLOW FULL ACCESS TO RTU
EQUIPMENT.
GAS LINE BEHIND EQUIPMENT
4GAS LINE AUTO
SHUT-OFF VALVE
112"112"G
5
J1004
NATURAL GAS CALCULATIONS
EQUIPMENT MBH
ROOFTOP EQUIPMENT:
RTU-1 270
RTU-2 270
WATER HEATING
WH-1 199
KITCHEN EQUIPMENT
OPEN FRYER 4 WELL 300
TOTAL GAS LOAD (MBH)1039.0
PLUMBING PLAN -
NATURAL GAS
P1.3
AUTHOR
CHECKER
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
1PLUMBING RISER - SANITARY WASTE & VENT
NTS
2PLUMBING RISER - DOMESTIC WATER
NTS
T0902
T2011
T2061
FCW-2
E2302
T0802
T2703
T0802
T2703
E2302
4"
3"
3"
FD
4"4"
4"
4"
4"
4"
4"
4"
3"
3"
3"
4"
4"
4"
4"
4"
3"
3"
3"
3"3"
3"
ECO
FCO
FCO
FCO
FCO
ECO
FS-2
FS-1
FS-1
FS-1
FD
FD
FD
FD
FD
FD
FCO
4"
3"
3"
3"
2"
2"
2"
2"
2"
2"
2"
2"
FD
WCO
WCO
WC
WC
LAV-1
LAV-1
4"
4"
4"
4"
4"4"
3"
2"
2"
2"2"
2"
2"
2"
2"
2"
2"
2"
112"
112"
112"
112"
112"
112"
112"
112"
112"
112"
112"
112"
3"
3"
M
REFER TO WATER
FILTRATION SYSTEM
DETAIL
114"
3 4"
3 4"
T1212
T0304
3 4" HW&CW
LAV-1
WC FPWH
WC
114"
FPWH
3 4"
3 4"
3 4"3 4"
12"12"
12"12"
12"
12"
12"
12"
12"
12"
3 4"
3 4"
12"
112"
FCW-3
FCW-4
K1401
MV
LAV-1
MV
MV
MV
3 4"
MV
ET-1
WH-1
QP0909 A0304
A0801
FCW-1
FCW-2
FCW-3
12"
12"
12"
12"12"
12"
3 4"
1"
12"
3 4" CW1"
1"
1"
1"
112"
112"
112"
112"
112"
112"
112"
3 4" HW
1"
1"
1"
T2213
GW
GW GW
GW
GW
GW
RCP
FD
FCO
4"
GW
GW 3"
T06024"
3"
3"
A0105
T1213
1"
WB
3 4"
12"
12"
12"
12"
12"
FW
RO
FW
RO
GI
3"
HD
A0202
QP0222
4"
4"
WCO
3"
FD
3"
FD
3"VTR
2"
2"
3"
112"2"
3"VTR
3"
3"
3"
3"3"
112"
2- WAY
FCO
2- WAY
FCO
112"
112"
3"
FS-1
112"
LAV-2
MV
112"
2"
LAV-2
WH-2
A0608
FCW-2
FCW-3
A0202
QP0222
FCW-3
FCW-1
12"
12"A0105
12"
PLUMBING RISERS
P2.0
AUTHOR
CHECKER
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
3'-9 1/2"
6'-10 3/4"
1'-6"
6'-0 1/2"
13'-3 1/2"
11
'
-
2
1
/
2
"
20
'
-
7
1
/
4
"
10
'
-
7
1
/
2
"
2'
-
7
"
13
'
-
1
1
"
12
'
-
1
0
"
17
'
-
1
0
3
/
4
"
11
'
-
5
1
/
2
"
9'
-
9
1
/
2
"
8'
-
4
3
/
4
"
9'
-
9
1
/
4
"
6'
-
4
1
/
4
"
6'
-
8
"
21'-1 1/4"
5'-11 3/4"
9'-9 1/4"
2'-2"
13'-4 1/4"
1'
-
0
1
/
2
"
8'
-
3
1
/
4
"
3'
-
5
3
/
4
"
11
'
-
5
3
/
4
"
16'-1 1/2"
3'
-
6
1
/
2
"
3'
-
5
3
/
4
"
5
1
/
2
"
12
'
-
1
0
1
/
4
"
23'-2"
24'-8 1/2"
30'-1 1/2"
31'-0 1/4"
30'-1 1/2"
30'-11 3/4"
13'-8 3/4"
11'-8 3/4"
25'-9 1/2"
1'
-
5
1
/
2
"
8'
-
2
1
/
4
"
9'
-
9
1
/
4
"
1'
-
1
0
3
/
4
"
6'
-
8
1
/
2
"
7'-2 3/4"
1PLUMBING PLAN - DIMENSION CALLOUT
1/4" = 1'-0"
DIMENSIONS ARE FOR REFERENCE ONLY.
GENERAL CONTRACTOR TO VERIFY LAYOUT
WITH WENDY'S REPRESENTATIVE.
28'-5"
0"
0"0"
0"
5'
-
4
1
/
2
"
REFERENCE POINT
OUTSIDE FACE OF
SHEATHING
15
'
-
6
1
/
2
"
1'-6 3/4"
2'-9 1/2"V2201
EX
T
.
R
A
M
P
LCA672LCE6120
15
'
-
5
"
15'-2 3/4"
8'-10 1/4"
PLUMBING DIMENSION
PLAN
P3.0
AUTHOR
CHECKER
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
BLOCKING BY GENERAL
CONTRACTOR
WOOD BLOCKING
CONTINUOUS
INSULATION
THROUGH PIPE
SUPPORT
WATER LINE INSULATION/PIPE SUPPORT
NOT TO SCALE
PIPE SUPPORT (IN-WALL)15
CW
G
VENT/INTAKE PIPE PROVIDED BY PLUMBING CONTRACTOR. PROVIDE 3" INTAKE PIPE AND 3" EXHAUST
PIPE FROM WATER HEATER TO CONCENTRIC VENT INTAKE AIR WALL TERMINATION KIT. MAKE ALL FINAL
INTAKE/ EXHAUST CONNECTIONS. COORDINATE LOCATION OF WALL OPENING WITH ARCHITECT PRIOR
TO ROUGH-IN. MAINTAIN 10' CLEARANCE FROM ALL OUTSIDE AIR INTAKES. INSTALL PER
MANUFACTURER'S RECOMMENDATION.
CHECK VALVE 1"
A.S.M.E. APPROVED
TEMPERATURE AND
PRESSURE RELIEF VALVE
SIZE GAS PER PLAN
EXTEND FULL SIZE TO
DRAIN
DRAIN VALVE
3/4"
1"
1"140° HW
THERMOMETER WITH
GAGE COCK (TYP.) -
EQUAL TO WATTS
#TB-1-1/2-1
SEE FLOOR PLAN FOR
CONTINUATION
VACUUM RELIEF VALVE
1"
1"
TO EXPANSION
TANK
3/4"TO RECIRC
PUMP
NOT TO SCALE
LARGE WATER HEATER 12
INSTALL PIPE HIGH AS POSSIBLE, ANCHORED TO WALL OF BOX WITH SUPPORTS AT MAXIMUM SIX FOOT
CENTERS. USE TYPE "M" HARD COPPER TUBE AND FITTINGS WITH LEAD-FREE SOLDER JOINTS. SLOPE
HORIZONTAL PIPE AT MINIMUM TWO PERCENT. REFER TO LOCAL CODE FOR INDIRECT DRAIN
REQUIREMENTS. ELECTRICAL AND PLUMBING CONTRACTORS TO COORDINATE WORK. ELECTRICAL
CONTRACTOR TO PROVIDE AND INSTALL HEAT TRACING.
FLOOR
1"DX COIL
CO
CO
NO INSULATION ON PIPE RISER
SEE FLOOR PLAN FOR RECEPTACLE LOCATION.
WALK-IN COOLER OR FREEZER BOX
PROVIDE TRAP AT
BOTTOM OF RISER AND
DISCHARGE INTO FLOOR
DRAIN OR FLOOR SINK
WITH AIR GAP OF TWO
PIPE DIAMETERS
SILICONE SEAL AROUND
PIPE PENETRATION
PROVIDE 1" ELASTOMERIC INSULATION OVER
FREEZE PROTECTION ON CONDENSATE LINE -
IF/WHEN FREEZER BOX ONLY - (PROVIDE
ELECTRIC HEAT TRACE CABLE PER PLAN.
COORDINATE POWER REQUIREMENTS)
PROVIDE CLEANOUT
IN TURNS AND ENDS
OF PIPE
MAKE CONNECTION TO
COIL AS REQUIRED
NOT TO SCALE
COOLER/FREEZER CONDENSATE 8
PROVIDE FIBERGLASS INSULATION WITH ALL-SERVICE JACKET WITH VAPOR BARRIER ON ALL COLD/HOT
WATER PIPING AND CONDENSATE DRAIN PIPE. REFER TO SPECIFICATIONS FOR FURTHER
INFORMATION REGARDING INSULATION. INSTALL ALL ITEMS PER SPECIFICATIONS AND
MANUFACTURERS INSTRUCTIONS. MAINTAIN VAPOR BARRIER ON COLD PIPING BY MEANS OF SEALANT
AND TAPE. FLAME-SPREAD AND SMOKE-DEVELOPED INDEXES SHALL NOT EXCEED 25/50. SEAL
EXPOSED ENDS OF FIBERGLASS INSULATION WITH ADHESIVE MASTIC.
REFER TO OTHER DETAILS
FOR TREATMENT OF
INSULATION AT PENETRATION
OF WALLS AND FIREWALLS
PROVIDE INSULATION ON DOMESTIC
HOT/COLD WATER PIPES, STORM WATER
PIPES, AND CONDENSATE DRAIN PIPING
IN WALLS AND CHASES
MITER THE INSULATION AT TEES AND
ELBOWS SO THAT THERE ARE NO GAPS
AT JOINTS. PROVIDE ONE-PIECE
PRE-MOULDED PVC FITTING COVERS
PROVIDE A ONE FOOT LENGTH OF
NON-COMPRESSIBLE INSULATION AT
HANGERS FOR ALL PIPE 2" AND
LARGER
COVER VALVE BODIES WITH INSULATION, BUT NOT UNIONS
TAPE JOINTS OF
FIBERGLASS
INSULATION
FLOOR
NOT TO SCALE
PIPE INSULATION 4
AI
R
G
A
P
2"
M
I
N
.
FINISHED
FLOOR
PVC PIPE (SIZE
WILL VARY)
3" SANITARY LINE (SEE
PLUMBING PLAN)
FLOOR SINK (BY PLUMBING
CONTRACTOR)
NOT TO SCALE
INDIRECT DRAIN 19
PROVIDE ONE PIECE SPUN ALUMINUM BASE
WITH, GRADUATED STEPPED PVC BOOT,
AND ADJUSTABLE STAINLESS STEEL
CLAMPS. SET BASE IN BED OF MASTIC
MINIMUM 12" BELOW ROOF
ROOF INSULATION
ROOF DECK
REFER TO ARCHITECT'S DRAWING
FOR APPLICATION OF VENT PIPE
BOOT INSTALLATION WITH
ROOFING MATERIAL
PROVIDE SLEEVE IF
REQUIRED BY TYPE
OF ROOF DECK
PROVIDE PIPE INCREASER
WHERE REQUIRED TO MAKE
MINIMUM 3" VENT THRU ROOF
ANCHOR PIPE TO ROOF DECK OR JOISTS
WITH U-BOLT AROUND PIPE AND ANGLE
IRON WELDED OR SCREWED TO DECK OR
JOIST
HUBLESS PIPE CONNECTORS ON CAST
IRON PIPE
REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR A MINIMUM OF 10 FEET
HORIZONTAL (UNLESS APPROVED BY ENGINEER PRIOR TO INSTALLATION) OR THREE FEET VERTICAL
ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, AND ONE FOOT FROM ANY VERTICAL SURFACE.
PROVIDE 1" FIBERGLASS INSULATION WITH ALL-SERVICE JACKET ON VENT PIPE INSIDE BUILDING
WITHIN SIX FEET OF VENT THRU ROOF LOCATION. VERIFY FLASHING AND COUNTERFLASHING WITH
ROOFING CONTRACTOR.
TERMINATE VENT FLUSH WITH
TOP OF PARAPET WALL.
NOT TO SCALE
VENT THRU ROOF (VTR)18
BALL VALVE:
BRONZE BODY,
FULL PORT,
SCREWED ENDS
(TYP)
FULL SIZED REDUCED
PRESSURE TYPE BACKFLOW
PREVENTION DEVICE
STRAINER: BRONZE BODY, STAINLESS SCREEN.
24
"
M
I
N
.
3" MIN.
6" MIN.
PRV SET AT
75PSI
SLEEVE AND CAULK
CITY WATER
METER
DETAIL SHOWS GENERAL SCHEMATIC REQUIREMENTS. PROVIDE BACKFLOW PREVENTER OF TYPE AND
MANUFACTURER APPROVED BY LOCAL AUTHORITIES. PROVIDE PRESSURE REDUCING VALVE ONLY IF
PRESSURE EXCEEDS 80 PSI - VERIFY. STRAINER AND REDUCING VALVE MAY BE INSTALLED IN VERTICAL
PIPE IF SPACE LIMITATIONS REQUIRE IT. CLEAN STRAINER BEFORE TURNING BUILDING OVER TO
OWNER. PROVIDE ANY REQUIRED CERTIFICATION OF TEST OF BACKFLOW PREVENTER TO LOCAL
AUTHORITIES.
FLOOR
TO FIXTURES
NOT TO SCALE
DOMESTIC WATER SERVICE ENTRY 14
MOP SINK
PC TO PROVIDE WATER HAMMER ARRESTERS BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS,
WATTS OR APPROVED EQUIVALENT WITH PISTON AND 0-RING CONSTRUCTION, HAVING PDI #WH-201,
ASSE #1010 OR ANSI #A112.26.1M CERTIFICATION. SIZE AND INSTALL PER PDI #WH-201 STANDARD OR
MANUFACTURER'S INSTRUCTION. THE TABLES ABOVE ARE BASED ON THE SIOUX CHIEF PRODUCT LINE.
IF PRESSURE IS IN EXCESS OF 65 PSIG THEN UPSIZE THE ARRESTER BY ONE (EXAMPLE: AN 'A'
ARRESTER WOULD BECOME A 'B' ARRESTER.)
UNIT LOAD
FIXTUREPDI
SIZE
SINGLE FIXTURE
KITCHEN SINKS
2.252.25
MULTIPLE FIXTURES
FIXTURE UNIT TABULATION
FIXTURE
3
HOT
-
3
COLD
10AA
A
B
C
D
1-3
4-11
12-32
33-60
61-113
ON HORIZONTAL BRANCH LINE LESS
THAN 20 FEET LONG, PLACE ONE WITHIN
SIX FEET OF THE LAST FIXTURE SERVED
ON BRANCH LINE GREATER THAN 20
FEET LONG, PLACE ANOTHER ARRESTER
IN THE MIDDLE, EACH IS SIZED FOR HALF
THE FIXTURE UNITS
LAVATORY
WATER CLOSET (VALVE)
HW OR
CW
ARRESTER
WITHIN SIX
FEET OF
FIXTURE
SERVED
HAND SINKS 1.51.5
WALL HYDRANT/HOSE BIB 22
1.51.5
NOT TO SCALE
WATER HAMMER ARRESTORS 6
ENTER BUILDING ABOVE GRADE WITH
SLEEVE. SEAL ENTRANCE INTO BUILDING
WEATHER-TIGHT
SIZE AS SHOWN ON PLAN - USE BLACK
STEEL PIPE
GAS METER - CFH
CAPACITY PER PLAN
SHUT-OFF
VALVE
GRADE OR
PAVEMENT
PRESSURE
REGULATOR (7"
W.C.)
EXTERIOR BUILDING WALL
BY GAS COMPANY (VERIFY)
FLOOR
BY PLUMBING CONTRACTOR
STRAINER
PRESSURE TEST COCK
PIPE INCREASER
VERIFY REQUIREMENTS FOR METERING AND PIPING WITH GAS COMPANY. GAS COMPANY SHALL
EXCAVATE, BACKFILL, AND REPAIR PAVING AND SOD FOR GAS SERVICE LINE INSTALLATION FROM MAIN
TO BUILDING. PLUMBING CONTRACTOR TO PAY ALL GAS COMPANY FEES FOR THIS INSTALLATION. USE
WELDED OR SCREWED PIPE AND FITTINGS PER SPECIFICATIONS. PAINT EXPOSED METAL GAS PIPE,
FITTINGS AND ITEMS TO MATCH BUILDING.
6" DEEP SEDIMENT TRAP
NOT TO SCALE
GAS SERVICE 2
SANITARY LINE (SEE
PLUMBING PLAN)
FINISH FLOOR
VENT LINE (SEE
PLUMBING PLAN)
3" CAPPED PVC PIPE
STUBBED 1'-0" AFF
NOT TO SCALE
HUB DRAIN 9
PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. MAKE PIPE SAME
SIZE AS TANK FITTING. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION PROCEDURE.
VERIFY PROPER OPERATION WHEN INSTALLED.
EXPANSION TANK INSTALLATION SHALL OCCUR ONLY WHEN THERE IS A BACKFLOW PREVENTION
DEVICE INSTALLED WITHIN THE BUILDING WATER SYSTEM.
WELDED STEEL
THEN OPEN VALVE
WATER PRESSURE,
PRESSURE TO MATCH
FILL TANK WITH AIR
AIR CHARGING VALVE
BUTYL DIAPHRAGM
POLYPROPYLENE LINING
EXPANSION TANK WITH
DISSIMILAR METALS
DIELECTRIC IF
TO WATER HEATER
COLD WATER SUPPLY
PIPE UNION:
NEXT TO PIPE TEE
PIPE HANGER
NOT TO SCALE
SMALL EXPANSION TANK 3
TO EXPANSION TANK IF
REQUIRED, SEE DETAIL
STRAP-ON AQUASTAT SET 5
DEGREES LOWER THAN
HEATER TEMPERATURE
H.W.
C.W.
STRAINER
RECIRCULATION PUMP
CHECK VALVE
WATER HEATER
PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. REFER TO "LARGE
WATER HEATER" DETAIL FOR MORE INFORMATION.
19RECIRCULATION PUMP
NOT TO SCALE
GB-250 - 100 GPM - 277 GALLON CAPACITY:
DETAIL SHOWS GENERAL SCHEMATIC REQUIREMENTS. CONTRACTOR SHALL SUBMIT PROPOSED
GREASE INTERCEPTOR INSTALLATION PLANS AND SPECIFICATIONS TO LOCAL AUTHORITIES FOR THEIR
APPROVAL BEFORE ACQUISITION. SEE MANUFACTURER INSTALLATION MANUAL FOR ADDITIONAL
INSTRUCTIONS.
BED OF UNDISTURBED EARTH OR COMPACTED SAND BACKFILL: 4" - 6"
24" DIAMETER HEAVY DUTY MANHOLES
4"4"
INLET DIFFUSER
OUTLET DIFFUSER
WATER LINE
NOT TO SCALE
GREASE INTERCEPTOR 15
PIPE OVER FOUR INCH
CLEVIS HANGER FOR
PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN HERE. DO NOT INSTALL HANGER
INSIDE INSULATION OR OTHERWISE PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM
ANOTHER EXCEPT IN CHASES. TRAPEZE HANGERS MAY BE USED FOR MULTIPLE PARALLEL PIPES.
HANGER SPACING FOR PIPE SIZE: COPPER: 4"=12'-0"; 3"=11'-0"; 212"=10'-0"; 2"=9'-0"; 112"=8'-0"; 114"=7'-0"; 1" &
3 4"=6'-0"; 12"=5'-0". CAST IRON: 10'-0" AND ONE NEAR ALL JOINTS. STEEL: 4"=14'-0"; 3"=12'-0"; 212"=11'-0";
2"=10'-0"; 112"=9'-0"; 1"=7'-0"; 3 4"=6'-0"; 12"=5'-0". LOCATE HANGERS AS CLOSE AS POSSIBLE TO TURNS AND
TEES OF PIPE. PROVIDE SUPPLEMENTARY STEEL STRUTS BETWEEN JOISTS IF REQUIRED. LOCATE
HANGERS TO TAKE LOAD OFF OF EQUIPMENT CONNECTIONS. ANCHOR WATER PIPE AGAINST SWAYING
DUE TO CHANGES IN WATER VELOCITY. PROVIDE SEISMIC BRACING IF/AS REQUIRED BY LOCAL
AUTHORITIES. CHAINS OR PERFORATED STRAP IRON OR STEEL IS NOT ACCEPTABLE. REFER TO
CODES FOR FURTHER INFORMATION.
PROVIDE GALVANIZED STEEL SADDLE FOR ALL INSULATED PIPE
LARGER THAN 3 4". VERIFY INSULATION THICKNESS WHEN SIZING
HANGERS.
ADJUSTABLE
BAND HANGER
FOR PIPING
FOUR INCH OR
LESS
TOP BEAM
C-CLAMP IF
STEEL BAR
JOIST
STEEL
DECK
ALL-THREAD ROD.
LENGTH AS REQ'D
FOR PIPE SLOPE
PROVIDE COPPER
OR NON-METALLIC
COATING WHERE
HANGERS CONTACT
BARE COPPER PIPE
DO NOT HANG PIPE
LARGER THAN 3" FROM
BOTTOM OF JOISTS.
NOT TO SCALE
PIPE HANGERS 5
BA
C
K
R
O
O
M
I
C
E
M
A
K
E
R
FI
L
T
E
R
BACKFLOW
PREVENTER
FC
W
-
2
FC
W
-
2
CO
F
F
E
E
TE
A
FI
L
T
E
R
FI
L
T
E
R
BOOSTER
PUMP
PRV
SCALE
STICK
3/4" CW
PR
E
S
S
U
R
E
G
A
U
G
E
P
S
B
FILTER LINES TO EQUIPMENT (BY OTHERS)
FILTER MANIFOLD MOUNTED ON WALL
NSF 61
TUBING
WATER LINE
PLAN OVERVIEW LAYOUT SEE DIAGRAM FOR COMPLETE DETAILS
MANIFOLDS ON DRINK RACK
3/4" COLD WATER LINE
F FF
AUTOMATIC
BY-PASS
MODULE
1/2" FCW-3
1/2" FCW-4
COMBI OVEN
(CLEANING CYCLE)
COMBI OVEN
(STEAM CYCLE)
RO SYSTEM
(MOUNTED AT MOP SINK)
1/
2
"
CW
FC
W
-
1
FC
W
-
1
FC
W
-
1
FC
W
-
1
FR
O
N
T
R
O
O
M
I
C
E
M
A
K
E
R
(D
I
N
I
N
G
R
O
O
M
B
E
V
E
R
A
G
E
U
N
I
T
)
FC
W
-
3
FC
W
-
3
FC
W
-
3
FC
W
-
3
1/
2
"
F
C
W
1/2"
1/2"
ICE MACHINE MANIFOLD
BEVERAGE LINE MANIFOLD
EQUIPMENT
MANIFOLD
NSF 61
TUBING
NSF 61
TUBING
BE
V
E
R
A
G
E
L
I
N
E
(D
R
I
V
E
-
T
H
R
U
)
BE
V
E
R
A
G
E
L
I
N
E
(D
I
N
I
N
G
R
O
O
M
)
CA
R
B
O
N
A
T
O
R
(U
T
I
L
I
T
Y
A
R
E
A
)
FILTER LINES
TO EQUIPMENT
(BY OTHERS)
FILTER LINES TO
EQUIPMENT (BY
OTHERS)
SP
A
R
E
24
"
A
F
F
.
OI
L
FRYERS
CAP
24"
UNION
WALL PENETRATION
3/4" USED OIL RECOVERY LINE MOUNTED TO WALL WITH
STANDOFF ANCHORS, ALL THREAD, AND SPLIT RING HANGERS.
COORDINATE WITH ARCHITECTURAL AND VENDOR DRAWINGS
FOR INSTALLATION. USED COOKING OIL LINE CANNOT
PROTRUDE MORE THAN 3" FROM THE WALL.
PITCH DOWN 1/4"
PER FOOT TO
USED COOKING
OIL TANK
3"
MAX.OIL
PROVIDE STAINLESS
STEEL ESCUTCHEON
AT WALL
7USED OIL RECOVERY LINE
NOT TO SCALE
NOT TO SCALE
WATER FILTRATION SYSTEM 1
HOT WATER TO WAREWASH AS
SHOWN ON PLANS
REFER TO SPECIFICATIONS AND
SCHEDULE
SET WATER HEATER ON PLATFORM
(BY OTHERS).
PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. REFER TO FLOOR
PLAN FOR PIPE SIZES. SET WATER HEATER THERMOSTAT AT 140° FAHRENHEIT. PROVIDE SEISMIC
STRAP OR BRACING AND FLEXIBLE CONNECTORS TO WATER AND GAS CONNECTIONS IF/AS REQUIRED
BY LOCAL AUTHORITIES.
SHUT-OFF VALVE PIPE UNIONS,
(DIELECTRIC REQUIRED FOR
DISSIMILAR METALS)
VALVE
DRAIN
PROVIDE A 210° F TEMPERATURE
AND 150 PSI PRESSURE RELIEF
VALVE WITH TEST LEVER SIZED WITH
AGA TEMPERATURE RATING 10%
OVER HEATING INPUT
HARD COPPER RELIEF DISCHARGE
LINE. FULL SIZE OF VALVE OUTLET TO
END OVER FLOOR SINK WITH 6 INCH
AIR GAP
140° FC HOT WATER SUPPLY TO
WATER HEATER
NOT TO SCALE
SMALL WATER HEATER ON PLATFORM 10
GAS
36
"
A
F
F
.
GA
S
1"
FRYERS
1-1/2"
1" NPT TO FRYER
1-1/2" GAS LINE. EXTEND THROUGH WALL TO AUTOMATIC
GAS SHUTOFF VALVE BELOW FINISHED CEILING
WALL
PENETRATIONS
3"
MAX.
QUICK DISCONNECT (TYP.)
1-1/2" GAS LINE MOUNTED TO WALL WITH STANDOFF ANCHORS,
ALL THREAD, AND SPLIT RING HANGERS. COORDINATE WITH
ARCHITECTURAL AND VENDOR DRAWINGS FOR INSTALLATION.
LINE TO EXTEND COMPLETELY THROUGH WALL AND UP TO VALVE
LOCATED BELOW CEILING. GAS LINE CANNOT PROTRUDE MORE
THAN 3" FROM THE WALL.
3" DEEP
SEDIMENT TRAP
11NATURAL GAS COOKING LINE
NOT TO SCALE
FR
O
N
T
R
O
O
M
I
C
E
M
A
K
E
R
(D
I
N
I
N
G
R
O
O
M
B
E
V
E
R
A
G
E
U
N
I
T
)
BE
V
E
R
A
G
E
L
I
N
E
(D
I
N
I
N
G
R
O
O
M
)
PLUMBING DETAILS
P4.0
AUTHOR
CHECKER
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
ANCHOR TANK LEGS TO FLOOR OR PLATFORM OR AS REQUIRED BY LOCAL CODE AUTHORITIES.
SET TANK AS CLOSE TO WALL AS POSSIBLE.
PROVIDE WOOD BLOCKS FOR SPACERS BETWEEN
WALL AND TANK IF REQUIRED. ATTACH TO WALL AS
REQUIRED (TYP FOR 2)
PROVIDE 1"x18" STEEL BAND DOWN 1/3 FROM THE
TOP, AND UP 1/3 FROM THE BOTTOM OF TANK. BEND
ENDS OF STRAP AND ANCHOR SECURELY TO WALL
AS REQUIRED. (TYP FOR 2)
WATER
HEATER
OR TANK
NOT TO SCALE
TANK SEISMIC RESTRAINT 3
SUPPLY PIPE
4" LONG
SEDIMENT TRAP
G
SHUT-OFF VALVE.PRESSURE REGULATOR AS
REQUIRED
UNION.
BLACK IRON. PAINT LINES
SAFETY YELLOW. ROUTE
LINES TO AVOID CONFLICTS ROOF
TO EQUIPMENT
NOT TO SCALE
ROOFTOP UNIT GAS CONNECTION 1
PIPE
SIZE
SPACING TRANSVERSE
BRACE
LONGITUDINAL
BRACE
BOLT
SIZE
ROD
SIZE
MAX
ROD
LENGTH
VERTICAL
BRACETR. LO.
1"-2" 20' 20' 2"X2"X18GA 2"X2"X18GA
14"3 8" 20" 2"X2"X18GA
212"-3" 40' 40' 2
12"X212"X16GA 2
12"X212"X16GA 3 8"12"25" 2"X2"X16GA
4"-5" 40' 40' 2
12"X212"X16GA 2
12"X212"X16GA 12"5 8" 31" 2"X2"X16GA
6" 40' 40' 2
12"X212"X12GA 2
12"X212"X12GA 12"3 4" 37" 2
12"X212"X16GA
8" 40' 40'212"X212"X12GA 2
12"X212"X12GA 5 8"7 8"43" 2
12"X212"X12GA
10" 20' 20' 2
12"X212"X12GA 2
12"X212"X12GA 3 4"7 8" 43" 2
12"X212"X12GA
DO NOT BRACE ANY PIPES WHERE TOP OF PIPE TO BOTTOM OF UPPER ATTACHMENT IS LESS THAN 12". BRACE GAS, OIL AND AIR PIPES 1" AND LARGER. BRACE ALL PIPES IN EQUIPMENT ROOMS 1-1/4" AND
LARGER. BRACE ALL OTHER PIPE 2-1/2" AND LARGER. BRACE HUBLESS CAST IRON PIPE ON EACH SIDE OF ANY CHANGE IN DIRECTION OF 90 DEGREES OR MORE. MAXIMUM HANGER ROD LENGTH IS 6 FEET.
WHERE LENGTH OF RUN EXCEEDS LONGITUDINAL BRACE SPACING, PROVIDE 2 FEET OFFSET IN PIPE AND LOCATE BRACE AT MID RUNS. REFER TO CURRENT EDITION OF SMACNA "SEISMIC RESTRAINT MANUAL" FOR
ALTERNATIVE ATTACHMENTS AND ADDITIONAL INFORMATION AND REQUIREMENTS. (THIS DETAIL APPLIES IN THE ABSENCE OF OTHER LOCAL CODE REQUIREMENTS.)
STANDARD STEEL PIPE CLAMP
TRANSVERSE BRACE
4" MAXIMUM TYPICAL ALL BRACES
2 MAX.
1 MIN.
1
LONGITUDINAL BRACE
1 MIN.
2 MAX.
WELD
1/8" 1"-24"
STEEL
BEAM
CONCRETE
1
WOOD BEAM
PROVIDE ROD SIZE TABULATED,
WITH VERTICAL BRACE IF ROD
LENGTH EXCEEDS TABULATION.
ANGLE IRON BRACE AND
BOLTS PER TABLE (TYP.)
STEEL JOIST
PIPE
HANGER
DRILLED IN THREADED INSERT.
DO NOT USE SHOT-IN INSERTS.
BOLT (WITH TWO
WASHERS)
BETWEEN JOIST
MEMBERS
BOLT (WITH TWO
WASHERS) NEAR
TOP OF BEAM
BOLT (WITH TWO
WASHERS) NEAR
TOP OF BEAM
UPC ZONE 3 OR
4; SMACNA
SHL-A
NOT TO SCALE
SEISMIC BRACING FOR PIPE 4
7'
-
1
1
"
12" NSF 61 TUBING
CARBONATOR
RACK
NOT TO SCALE
CARBONATOR RACK ROUGH-IN 7
3" MAX.
2'
-
0
"
3'
-
0
"
1'
-
0
"
WHEEL CHOCK (BY OTHERS)
GAS MANIFOLD
USED COOKING OIL LINE
RESTRAINING CABLE (BY OTHERS)
REFER TO HOOD DRAWINGS
9GAS FRYER INSTALLATION
NOT TO SCALE
2'
-
6
"
2'-6"
WB WATER BOX WITH CAPPED DRAIN OUTLET. MARK
SUPPLY OUTLETS WITH R.O. AND F.W. STICKERS.
12" PEX-A FW TUBING IN WALL
COMBI
OVEN
12" PEX-A RO TUBING WALL
NOT TO SCALE
COMBI OVEN WATER ROUGH-IN 6
7'
-
4
3
/
4
"
T.O.F.F.
CEILING
8'-10"
WH-2
5'
-
1
3
/
4
"
T2061
3 4"HW
3 4"HW
5WAREWASH W/ WATER HEATER
NOT TO SCALE
PLUMBING DETAILS
P4.1
AUTHOR
CHECKER
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
PLUMBING SPECIFICATIONS
20500 GENERAL PROVISIONS
A. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL A
PLUMBING SYSTEM, COMPLETE AS INDICATED ON THE DRAWINGS, AS REQUIRED BY CODE AND AS
SPECIFIED HEREIN.
B. WITHOUT RESTRICTING THE GENERALITY OF THE FIRST STATEMENT, THE WORK TO BE
PERFORMED UNDER THIS DIVISION SHALL INCLUDE, BUT IS NOT LIMITED TO, THE FOLLOWING:
1. PLUMBING WORK AS DESCRIBED IN SECTIONS 220500 THROUGH 224000.
C. THE ELECTRICAL CONTRACTOR, UNLESS OTHERWISE NOTED, IS TO PROVIDE POWER WIRING FOR
EACH ITEM OF ELECTRICAL EQUIPMENT AND MAKE FINAL CONNECTIONS TO MOTORS.
D. ALL FINISH PAINTING IS TO BE PERFORMED BY THE GENERAL CONTRACTOR, EXCEPT AS NOTED
ELSEWHERE. THIS CONTRACTOR SHALL RESTORE TO ORIGINAL CONDITION ANY PAINTING
DEFACED BY THIS CONTRACTOR AFTER ORIGINAL PAINTING.
E. ALL WORK SHALL CONFORM TO CODES, RULES, AND REGULATIONS:
1. STATE PLUMBING CODE.
2. LOCAL BUILDING CODE.
3. NATIONAL FIRE PROTECTION ASSOCIATION.
4. CERTAIN CODES AND STANDARDS AS SET UP BY VARIOUS TECHNICAL SOCIETIES SUCH AS
ASME, ASHRAE, ASTM, SMACNA, ARI, AABC, OR IEEE.
5. FEDERAL OCCUPATIONAL SAFETY AND HEALTH STANDARDS.
6. LOCAL INSPECTOR'S REQUIREMENTS.
7. STATE INDUSTRIAL COMMISSION REQUIREMENTS.
8. BUILDING INSURING AGENCY REQUIREMENTS.
F. ALL PERMITS REQUIRED BY LAWS, ORDINANCES AND BUILDING CODES HAVING JURISDICTION
SHALL BE OBTAINED AT THE PROPER TIME BY AND AT THE EXPENSE OF THIS CONTRACTOR.
G. THIS CONTRACTOR SHALL OBTAIN ALL INSPECTIONS REQUIRED BY ALL LAWS, ORDINANCES AND
PUBLIC AUTHORITY HAVING JURISDICTION AND SHALL OBTAIN CERTIFICATES OF SUCH
INSPECTIONS AND SUBMIT SAME TO THE ARCHITECT AND SHALL PAY ALL FEES, CHARGES,
ASSESSMENTS AND OTHER EXPENSES IN CONNECTION THEREWITH.
H. PIPING AND EQUIPMENT LAYOUT IS SCHEMATIC. EXACT LOCATIONS ARE DETERMINED BY
STRUCTURAL AND OTHER CONDITIONS. DESIGN OF SYSTEM MAY NOT BE CHANGED. ONLY EXACT
LOCATION OF PIPING MAY BE REVISED TO SUIT CONSTRUCTION CONDITIONS AND AID IN
COORDINATION WITH WORK OF OTHER CONTRACTORS.
I. THE MATERIALS AND EQUIPMENT INSTALLED IN THE WORK SHALL MEET THE REQUIREMENTS OF
THE CONTRACT DOCUMENTS AND NO MATERIALS OR EQUIPMENT SHALL BE ORDERED UNTIL
REVIEWED BY THE ENGINEER AND/ OR ARCHITECT.
J. THIS CONTRACTOR SHALL SUBMIT SHOP DRAWINGS PER THE DOCUMENTS PROVIDED BY THE
OWNER/ARCHITECT/CONTRACTOR.
1. EXPANSION TANK
2. DRAINS AND CLEANOUTS
3. VALVES
4. ALL PLUMBING FIXTURES, FAUCETS AND FITTINGS
5. WATER HEATER
6. PIPE INSULATION
7. GREASE INTERCEPTOR
K. CATALOG DATA FOR EQUIPMENT REVIEWED BY THE ARCHITECT SHALL NOT SUPERSEDE THE
ENGINEER'S CONTRACT DOCUMENTS. THE REVIEW OF THE ENGINEER SHALL NOT RELIEVE THE
CONTRACTOR FROM RESPONSIBILITY FOR DEVIATIONS FROM DRAWINGS OR SPECIFICATIONS,
PROVIDING PROPER CLEARANCE FABRICATION PROCESS AND COORDINATION WITH OTHER
TRADES.
L. WHEN SUBMITTED FOR THE ARCHITECT'S REVIEW, SHOP DRAWINGS SHALL BEAR THE
CONTRACTOR'S CERTIFICATION THAT THEY HAVE REVIEWED, CHECKED AND APPROVED THE SHOP
DRAWINGS, THAT THEY ARE IN HARMONY WITH THE REQUIREMENTS OF THE PROJECT AND WITH
THE PROVISIONS OF THE CONTRACT DOCUMENTS AND THAT THEY HAVE VERIFIED ALL FIELD
MEASUREMENTS AND CONSTRUCTION CRITERIA, MATERIALS, CATALOG NUMBERS AND SIMILAR
DATA. CONTRACTOR SHALL ALSO CERTIFY THAT THE WORK REPRESENTED BY THE SHOP
DRAWINGS IS RECOMMENDED BY THE CONTRACTOR AND THE CONTRACTOR'S GUARANTEE WILL
FULLY APPLY.
M. ALL CONTRACTORS SUBMITTING PROPOSALS FOR THIS WORK SHALL FIRST EXAMINE THE SITE
AND ALL CONDITIONS THEREIN. ALL PROPOSALS SHALL TAKE INTO CONSIDERATION ALL SUCH
CONDITIONS AS MAY AFFECT THE WORK UNDER THIS CONTRACT. THE SUBMITTING OF A BID
AUTOMATICALLY IMPLIES THAT THIS EXAMINATION OF SITE HAS BEEN DONE.
N. CONTRACTOR SHALL VERIFY LOCATION OF UTILITIES AND NOTE CONDITIONS WHICH WOULD
AFFECT THE WORK. ALL DISCREPANCIES SHALL THEN BE REPORTED PRIOR TO THE BID AWARD.
O. PROVIDE INSTRUCTION TO OWNER'S OPERATING PERSONNEL AS NECESSARY, SHOWING
LOCATIONS AND PROPER OPERATION OF MAJOR ITEMS OF EQUIPMENT AND SYSTEM
COMPONENTS AND REFERRING TO THE OPERATING INSTRUCTION MANUAL DESCRIBED BELOW AS
A GUIDE.
P. COMPILE A WRITTEN MANUAL OF OPERATING INSTRUCTIONS INCLUDING COPIES OF SHOP
DRAWINGS AND A LISTING OF EQUIPMENT SUPPLIERS. ASSEMBLE IN 8-1/2" X 11" HARD BACKED
INDEXED BINDER. MATERIAL SHALL BE AS FOLLOWS:
1. TITLE PAGE: TITLE OF JOB, TENANT, ADDRESS, DATE OF SUBMISSION, CONTRACTOR AND
ENGINEER.
2. INDEX.
3. ST OF MAJOR EQUIPMENT USED IN PROJECT ACCOMPANIED BY CONTRACTOR PURCHASE
ORDER NUMBERS AND SUPPLIERS NAMES AND ADDRESSES.
4. ONE COPY OF EACH SHOP DRAWING GROUPED BY TYPES OF EQUIPMENT, I.E., PLUMBING
FIXTURES, VALVES, ETC.
5. SECTION FOR EACH SYSTEM INCLUDING:
5.1. BRIEF DESCRIPTION OF SYSTEM OPERATION WITH LOCATION OF MAJOR COMPONENTS.
5.2. LIST OF ITEMS IN SYSTEM REQUIRING PERIODIC SERVICE.
Q. SUBMIT A COMPLETED COPY TITLED "PLUMBING OPERATING INSTRUCTION MANUAL" ON THE
BINDING EDGE OF BINDER TO ARCHITECT FOR APPROVAL. AFTER ARCHITECT'S REVIEW AND ANY
CORRECTIONS REQUIRED ARE COMPLETED, SUBMIT A COPY OF THE MANUAL, TO THE OWNER.
220502 FIRESTOPPING
A. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR FIRESTOPPING AROUND ALL OPENINGS FOR
PIPES, DUCTS, CONDUITS ETC., INSTALLED BY CONTRACTOR AT ALL FIRE WALLS. FIRESTOPPING
SHALL BE PERFORMED BY AN INSTALLER WHO HAS BEEN TRAINED BY THE MANUFACTURER, OR
MANUFACTURER'S REPRESENTATIVE, IN THE INSTALLATION PROCEDURES BASED ON PUBLISHED
UL TESTED FIRE STOP SYSTEMS.
B. FIRESTOPPING SHALL MEET THE REQUIREMENTS OF ASTM E-814 OR UL 1479 FIRE TESTS BY A
RECOGNIZED TESTING AGENCY. FIRESTOPPING SHALL ALSO CONFORM TO THE FOLLOWING
GOVERNING CODES: INTERNATIONAL BUILDING CODE, NFPA 101- LIFE SAFETY CODE & NFPA 70 -
NATIONAL ELECTRIC CODE.
C. PENETRATION
1. CLEAN PENETRATION HOLES OF DIRT, LOOSE MATERIALS AND FOREIGN MATTER WHICH MAY
AFFECT BOND OR INSTALLATION.
2. REMOVE COATINGS SUCH AS PAINT, CURING COMPOUNDS, WATER REPELLENT & SEALERS
AS REQUIRED.
3. INSTALL BACKING MATERIALS TO PREVENT LIQUID MATERIAL LEAKAGE.
D. APPLICATION
1. PREPARE AND APPLY PENETRATION SEALING SYSTEMS IN ACCORDANCE WITH
MANUFACTURER'S PRINTED INSTRUCTIONS.
2. EMPLOY INSTALLATION TECHNIQUES WHICH WILL ENSURE THAT FIRESTOPPING IS
DEPOSITED TO FILL AND SEAL HOLES AND OPENINGS.
3. TOOL EXPOSED SURFACES OF APPLIED SEALANT TO SMOOTH FINISH.
4. PROTECT MATERIALS FROM DAMAGE ON SURFACES SUBJECTED TO TRAFFIC.
E. PROVIDE INTUMESCENT SEALANTS AND COLLARS AT OPENINGS INVOLVING PLASTIC OR
INSULATED PIPE SIMILAR TO THE METACAULK SERIES 880 AND 950.
F. FIRESTOPPING BY DOW CORNING, 3M, HILTI OR METACAULK MAY FURNISHED AT THE
CONTRACTOR'S OPTION.
220529 PIPE ANCHORS, HANGERS AND SUPPORTS
A. ALL PIPING SHALL BE SEPARATELY HUNG AND SUPPORTED FROM APPROVED STRUCTURAL
MEMBERS OR CONCRETE OVERHEAD STRUCTURE ONLY. NO PIPE SHALL BE HUNG FROM ROOF
DECK, PIPE, DUCTS OR OTHER COMPONENTS OR EQUIPMENT OF OTHER TRADES.
B. PROVIDE LISTED/APPROVED ADJUSTABLE HANGERS, INSERTS, BRACKETS, CLAMPS,
SUPPLEMENTARY STEEL AND OTHER DEVICES REQUIRED FOR PROPER SUPPORT OF ALL PIPE
LINES.
C. HANGERS SHALL BE DESIGNED TO ALLOW FOR EXPANSION AND CONTRACTION AND TO ALLOW
INSULATION (WHERE APPLICABLE) TO RUN CONTINUOUSLY THROUGH HANGERS.
D. WIRE OR STRAP HANGERS ARE NOT PERMITTED. ADJUST HANGERS SO AS TO DISTRIBUTE WEIGHT
LOAD EQUALLY ON ATTACHMENTS.
220548 PLUMBING SYSTEM TESTING
A. SYSTEM TESTING SHALL PROVIDE FOR THE FOLLOWING:
1. TEST NEW INTERIOR DOMESTIC WATER SYSTEM.
2. TEST ALL SOIL, WASTE, AND VENT PIPING.
3. FURNISH ALL PUMPS FOR AIR AND WATER PRESSURE TESTS ALONG WITH GAUGES AND ANY
OTHER REQUIRED TEST EQUIPMENT.
4. UNDERGROUND LINES TO BE TESTED BEFORE BEING CONCEALED. CONTRACTOR SHALL
REPAIR ANY LEAKS AND ALL DAMAGE RESULTING THEREFROM.
5. CHANGES IN AMBIENT TEMPERATURE WILL BE TAKEN INTO ACCOUNT WHEN TESTING
UNDERGROUND PIPING, HOWEVER, THE VARIOUS SYSTEMS SHALL BE THOROUGHLY
INSPECTED FOR LEAKS BEFORE HYDROSTATIC PRESSURE TESTS ARE CONCLUDED.
6. INTERIOR WATER PIPING: HYDROSTATIC TEST AT 125 PSI AWWA PROCEDURES AND TO THE
SATISFACTION OF LOCAL AUTHORITY HAVING JURISDICTION.
7. SOIL, WASTE, AND VENT PIPING SHALL BE WATER AND SMOKE OR AIR TIGHT (STATE
PLUMBING CODE).
B. MEASURE LEAKAGE BY METERING WATER REQUIRED TO MAINTAIN LINE PRESSURE. REMOVE AIR
BEFORE TESTING.
C. REPAIR ANY LEAKING JOINTS AND DEMONSTRATE ACCEPTABLE LEAKAGE TO SATISFACTION OF
OWNER'S REPRESENTATIVE AND APPROVING AUTHORITY. FLUSH ALL PIPING BEFORE PLACING
INTO OPERATION.
220550 STERILIZATION
A. STERILIZE NEW DOMESTIC WATER LINES AFTER INSTALLATION.
B. FURNISH A CERTIFICATE OF STERILIZATION AND APPROVAL FOR HUMAN CONSUMPTION TO BE
SIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THIS STATE, REGULARLY EMPLOYED BY
THE TESTING LABORATORY. CERTIFICATE MUST BE GIVEN TO THE ARCHITECT AND OWNER
BEFORE FINAL PAYMENT WILL BE MADE.
C. STERILIZATION SHALL BE BY MEANS OF CHLORINE INJECTED INTO THE WATER SYSTEM NEAR THE
SOURCE AND OUTLETS THROUGHOUT THE SYSTEM SHALL BE TESTED TO PROVE PRESENCE OF
MINIMUM REQUIREMENTS. LEAVE CHLORINE IN FOR 24 HOURS AND FLUSH OUT SYSTEM UPON
COMPLETION OF WORK. STERILIZATION PROCEDURE SHALL BE WITNESSED BY THE OWNER'S
REPRESENTATIVE.
D. STERILIZATION SHALL BE PERFORMED UNDER THE IMMEDIATE SUPERVISION OF A WATER TESTING
LABORATORY REGULARLY ENGAGED IN THE SERVICE AND SHALL BE DONE ACCORDING TO THEIR
INSTRUCTIONS.
220560 IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT
A. STENCILS, LABELS, TAGS, AND COLOR CODES SHALL CONFORM TO ANSI A13.
B. PRODUCTS SHALL BE SETON. EQUAL PRODUCTS BY BRADY MAY BE FURNISHED AT
CONTRACTOR'S OPTION.
C. STENCILS FOR EQUIPMENT SHALL BE REUSABLE AND HAVE 1" HIGH CHARACTERS. CHARACTERS
SHALL BE PAINTED WHITE OVER A BLACK BACKGROUND. STENCIL ONLY AFTER FINAL PAINTING IS
COMPLETE. CHARACTERS SHALL BE LEGIBLE FROM FLOOR. APPLY CLEAR ACRYLIC, LACQUER, OR
VARNISH OVER THE FINISHED STENCIL.
D. FOR PIPING PROVIDE ANSI STANDARD COLOR FLEXIBLE VINYL LABELS WITH PERMANENT
PRESSURE SENSITIVE ADHESIVE BACK. LABEL SHALL BE OF SUFFICIENT LENGTH TO ENCIRCLE
THE PIPE (AND INSULATION WHEN APPLICABLE) AND OVERLAP ON ITSELF. EACH LABEL SHALL
HAVE AT LEAST ONE FLOW DIRECTION ARROW AND SHALL BE PERMANENTLY LABELED WITH PIPE
CONTENT.
E. SYSTEM PIPING TO LABLED SHALL INCLUDE THE FOLLOWING:
1. DOMESTIC WATER (INCLUDING COLD, HOT, RECIRCULATING, FILTERED, AND REVERSE
OSMISIS)
2. SANITARY WASTE AND VENT (ABOVE GRADE ONLY)
3. NATURAL GAS
4. USED COOKING OIL
F. DOMESTIC WATER PIPING SHALL BE LABLED ON EXTEROR OF INSULATION IN ACCORDANCE WITH
ANSI A13.
G. PIPING, VALVES, DRAINS, CONTROL PANELS AND SIMILAR EQUIPMENT SHALL BE IDENTIFIED AS TO
FUNCTION AND SYSTEM NUMBER AS DIRECTED BY THE OWNER'S REPRESENTATIVE AND AS LISTED
BELOW:
IDENTIFICATION ITEM : TYPE
PIPING : STENCIL OR PIPE LABEL
VALVES : TAG
PIPING SPECIALTY : TAG
WATER HEATER AND OTHER EQUIPMENT : STENCIL
H. IDENTIFY PIPE LINES WITH STENCIL OR PIPE LABEL WITH COLOR CODED BANDS AT THE
FOLLOWING LOCATIONS:
1. AT EQUIPMENT CONNECTION AT EACH VALVE.
2. AT BOTH SIDES OF WALLS THROUGH WHICH PIPE PASSES.
3. AT EVERY 20 FT. INTERVAL ON CONTINUOUS PIPE LINES.
4. AT EACH BRANCH CONNECTION.
5. SHOW FLOW DIRECTION ARROWS AT EACH IDENTIFICATION POINT.
220700 INSULATION
A. PIPE INSULATION AND APPURTENANCES AND COVERINGS ON PIPES USED IN CHASES, SHAFTS OR
OTHER CONCEALED SPACES IN TYPES 1 AND 2 CONSTRUCTION SHALL HAVE A FLAME SPREAD
RATING NOT EXCEEDING TWENTY-FIVE (25) AND IN TYPE 3 AND 4 CONSTRUCTION NOT EXCEEDING
SEVENTY-FIVE (75) AND A SMOKE DEVELOPED RATING NOT EXCEEDING FIFTY (50).
B. INSULATION SHALL BE RIDGE ONE-PIECE FIBERGLASS PIPE INSULATION WITH REQUIREMENTS
COMPLYING WITH ASTM C 547, SELF-SEALING ADHESIVE LAP LONGITUDINAL JOINTS AND BUTT
STRIPS FOR TRANSVERSE JOINTS. JACKETING SHALL CONFORM TO ASTM C 1136, TYPE I,
MAXIMUM VAPOR TRANSMISSION RATING OF 0.02 PERM WHEN TESTED ACCORDING TO ASTM E 96,
PROCEDURE A. (K VALVE) 0.25 BTU/IN./HR. * FT2 * °F AT 75°F MEAN TEMPERATURE WITH A MINIMUM
R-VALVE OF R4.
PROVIDE INSULATION THICKNESS AS INDICATED:
DOMESTIC COLD WATER PIPING 1" AND SMALLER: 1/2" THICKNESS
DOMESTIC COLD WATER PIPING 1-1/4" - 1-1/2": 3/4" THICKNESS
DOMESTIC COLD WATER 2" AND LARGER: 1" THICKNESS
DOMESTIC HOT WATER PIPING 3/4" AND SMALLER: 1" THICKNESS
DOMESTIC HOT WATER PIPING 1" - 1-1/2: 1-1/2" THICKNESS
PLUMBING VENT PIPING WITHIN 6 FEET OF ROOF OUTLET: 1" THICKNESS
CONDENSATE PIPING: 1/2" THICKNESS
USED COOKING OIL : 1" THICKNESS
C. GLUE IN PLACE WITH SCHULLER U-GLUE.
D. THE FITTINGS SHALL BE INSULATED WITH SCHULLER ZESTON INSULATION AND HAVE FACTORY
PREMOLDED PVC COVERS. BUTT THE JOINTS TOGETHER AND WRAP WITH 3" WIDE STRIP TAPE,
SEAL IN PLACE WITH SCHULLER U-GLUE.
E. INSULATION SHALL NOT BE APPLIED UNTIL THE GENERAL CONSTRUCTION HAS PROGRESSED
SUFFICIENTLY TO INSURE AGAINST PHYSICAL OR MOISTURE DAMAGE TO THE INSULATION. ALL
INSULATION DAMAGED THROUGH FAILURE TO OBSERVE THIS DIRECTIVE SHALL BE REPLACED AT
PLUMBING CONTRACTOR'S EXPENSE.
F. INSTALL ALL INSULATION ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.
G. INSULATION SHALL NOT BE APPLIED OVER FLANGES, JOINTS AND SEAMS IN PIPING.
H. INSULATION SHALL BE SCHULLER. EQUAL PRODUCT BY ARMSTRONG, CERTAINTEED,
OWENS-CORNING OR KNAUF MAY BE FURNISHED AT THE CONTRACTOR'S OPTION.
221113 PLUMBING BASIC MATERIALS AND METHODS
A. PROVIDE AND ERECT THE FOLLOWING PIPING AS SHOWN ON THE DRAWINGS AND/OR AS
REQUIRED.
1. SANITARY BUILDING DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON SOIL
PIPE.
2. SCHEDULE 40 PVC PIPING MAY BE USED FOR SANITARY WASTE AND VENT PIPING AT THE
CONTRACTOR'S OPTION IF CEILING SPACE IS NOT USED AS A RETURN AIR PLENUM SPACE.
3. DOMESTIC HOT AND COLD WATER USE TYPE "L" HARD COPPER PIPE.
4. CAST IRON - NON-COMBUSTIBLE PIPING REQUIRED IN WALL AT HOODS.
B. THIS CONTRACTOR IS TO BECOME INFORMED OF THE EXACT DIMENSIONS OF FINISHED WORK
WHERE PIPES ARE TO BE PLACED AND WILL ARRANGE THE WORK ACCORDINGLY, ASSUMING ALL
RESPONSIBILITY FOR PROPER LOCATION. IN THE ERECTION OF THE MAINS, SPECIAL CARE SHALL
BE USED PROVIDING SUPPORT AND PROPER ALLOWANCES SHALL BE MADE FOR EXPANSION.
C. ALL PIPE LINES MUST BE PROVIDED WITH A SUFFICIENT NUMBER OF FITTINGS OR UNIONS TO
MAKE POSSIBLE DISASSEMBLY WITHOUT BREAKAGE OF FITTINGS.
D. ALL EXPOSED PIPING SHALL BE NEAT AND CAREFULLY ALIGNED WITH THE STRUCTURAL
ELEMENTS OF THE BUILDING. NO OFFSETS OR OBLIQUE BENDS WILL BE PERMITTED. DRAWINGS
ARE DIAGRAMMATIC AND SHOULD NOT BE USED FOR LAYOUT WORK.
E. ALL LOW POINTS IN WATER PIPING TO HAVE DRAIN VALVES WITH STANDARD HOSE ATTACHMENTS.
HOT AND COLD WATER PIPING IS TO PITCH TOWARD THE NEAREST DRAIN VALVE.
F. ALL PIPES TO BE INSTALLED SHALL BE LOCATED AT SUFFICIENT DISTANCE FROM WALLS, OTHER
PIPES, CONDUIT, DUCTWORK AND OTHER OBSTACLES TO AVOID INTERFERENCE AND TO PERMIT
THE APPLICATION OF FULL THICKNESS OF INSULATION SPECIFIED.
G. MECHANICAL JOINT TYPE PIPING SHALL BE INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS. THERMOMETERS BY TRERICE, ASHCROFT, MARSHALLTOWN, AND WEISS
ARE ACCEPTABLE.
221000 PLUMBING SYSTEMS
A. SANITARY BUILDING DRAIN, SOIL, WASTE AND VENT LINES SHALL BE SERVICE WEIGHT CAST IRON
HUBLESS PIPE WITH STAINLESS STEEL AT COUPLINGS. SCHEDULE 40 PVC MAY BE USED FOR
SANITARY WASTE AND VENT PIPING IF CEILING SPACE IS NOT USED AS A RETURN AIR PLENUM.
TYPE NO. S1110-4 MAY BE USED IN LIEU OF FIELD FABRICATED FLASHINGS.
B. VENT STACKS SHALL EXTEND THROUGH THE BUILDING, TERMINATING 12" ABOVE THE ROOF.
STANDARD FLASHING SHALL BE EXTENDED 12" IN ALL DIRECTIONS FROM THE VENT TERMINAL AND
TURNED DOWN INTO VENT. FLASHING UNITS AS MADE BY STONEMAN CAULK TYPE NO. S1110-4 MAY
BE USED IN LIEU OF FIELD FABRICATED FLASHINGS.
C. HORIZONTAL RUNS SHALL BE GIVEN AS STEEP A PITCH TOWARD THE OUTLET AS CONDITIONS WILL
PERMIT BUT NOT LESS THAN 1/8" PER FOOT.
D. FULL "Y" BRANCH FITTINGS AND EXTENSION WITH BRASS NIPPLES AND FINISHED SCREW PLUGS
FOR CLEANOUTS SHALL BE PLACED IN ACCESSIBLE POSITIONS AT ENDS OF HORIZONTAL LINES OF
PIPE AND AT FOOT OF ALL VERTICAL LINES OF PIPE OR ELSEWHERE, AS MAY BE REQUIRED BY THE
CODE.
E. WHERE CLEANOUTS OCCUR IN FINISHED AREAS, THEY SHALL BE RECESSED AND COVERS TO BE
FLUSH WITH THE FLOOR OR WALL.
F. HOT AND COLD WATER PIPING SHALL BE PROVIDED AS FOLLOWS:
1. TYPE "L" HARD COPPER TUBE WITH SOLDER FITTINGS. COPPER TUBING SHALL HAVE SWEAT
JOINTS AND BE CLEAN OF SCALE AND FOREIGN MATTER BEFORE INSTALLATION. ALL ENDS
OF TUBING TO BE SWEATED SHALL BE REAMED, CLEANED AND BURNISHED TO REMOVE DIRT
AND OXIDE. HARD 95-5 LEAD-FREE SOLDER SHALL BE USED AND APPLIED TO THE JOINTS
ACCORDING TO STANDARD PRACTICE AND/OR MANUFACTURER'S RECOMMENDATIONS.
COMPRESSION STOPS AND BRAIDED SUPPLIES SHALL BE USED AT CONNECTION TO
EQUIPMENT.
2. PEX-A TUBING WITH ASTM F1960 FITTINGS. PEX TUBING SHALL BE SUPPORTED WITH
ADDITIONAL PEX-A PIPE CHANNEL PER MANUFACTURER'S RECOMENDATIONS. PEX PIPING
SHALL BE TERMINATED AT FIXTURES WITH PREMANUFACTURERED COPPER STUBOUTS.
COMPRESSION STOPS, AND BRAIDED SUPPLIES SHALL BE USED AT CONNECTION TO
EQUIPMENT. PROVIDE RED TUBING FOR HOT WATER, BLUE TUBING FOR COLD WATER, AND
WHITE/TRANSLUCENT TUBING FOR ALL OTHER DOMESTIC WATER.
G. EACH HOT AND COLD WATER BRANCH SHALL BE PROVIDED WITH A BALL VALVE SHUT-OFF.
H. GREASE INTERCEPTOR - SHALL BE AS SPECIFIED ON DRAWINGS.
221118 GAS PIPING
A. ASTM A-53 SCHEDULE 40 STEEL PIPE PAINTED WITH YELLOW ANTI-CORROSIVE PAINT, SCREWED
OR WELDED IN ACCORDANCE WITH CODE REQUIREMENT (FITTINGS FOR LINES LARGER THAN 2"
SHALL BE WELDED STEEL. FITTINGS FOR LINES 2" AND SMALLER, EXCEPT WHEN LOCATED IN AIR
PLENUMS, SHALL BE SCREWED. STANDARD WEIGHT BLACK MALLEABLE). NO VALVES ARE TO BE
LOCATED IN AIR PLENUMS.
B. GAS COCK'S 1-1/2" AND SMALLER SHALL BE ALL BRONZE, SCREWED, FLAT HEAD, BRASS PLUG AND
WASHER 200 LB. NOG. PROVIDE LINE SIZE 6" LONG DIRT LEG DOWN STREAM OF GAS COCK AT ALL
EQUIPMENT CONNECTIONS.
C. PROVIDE AND INSTALL THE NATURAL GAS MANIFOLD FOR COOKING EQUIPMENT WHEN NATURAL
GAS IS USED FOR FRYERS.
D. ALL EQUIPMENT SHALL SHALL BE CONNECTED WITH RIGID PIPING AS SPECIFIED ABOVE, FLEXIBLE
CONNECTORS ARE NOT ACCEPTABLE.
E. PROVIDE UNION AT ALL EQUIPMENT CONNECTIONS.
F. PROVIDE GAS PIPE SUPPORTS IN ACCORDANCE WITH CODE REQUIREMENTS.
221120 DRAIN PIPING
A. FURNISH AND INSTALL A GRAVITY DRAIN PIPING SYSTEM FROM WATER HEATER, TERMINATING AT
THE MOP SINK.
B. PIPING IS TO BE SCHEDULE 40 PVC WITH DRAINAGE PATTERN FITTINGS, BONDED ACCORDING TO
THE MANUFACTURERS RECOMMENDATIONS.
C. PIPING IS TO BE SECURED TO PIPE HANGERS, USING PROPER SPACING AND THE APPROPRIATE
HEIGHT TO ALLOW THE PIPE TO PITCH PROPERLY.
221140 PLUMBING PIPING SPECIALTIES - USED COOKING OIL
A. ASTM A-53 SCHEDULE 40 STEEL PIPE THRESED AND SCREWED OR WELDED WITH STANDARD
WEIGHT BLACK MALLEABLE FITTINGS.
B. PROVIDE UNION AT ALL EQUIPMENT CONNECTIONS.
C. PROVIDE PIPE SUPPORTS AND STANDOFF HANGERS IN ACCORDANCE WITH CODE
REQUIREMENTS.
D. EXTERIOR UCO PIPING WITH INSULATION TO THE EXTERIOR TANK REQUIRES A STAINLESS STEEL
INSULATION JACKET WITH ALL JOINTS AND SEAMS SEALED WATER TIGHT USING WATERPROOF UV
RESISTANT CLEAR SEALANT (3M CLEAR HYBRID 730 UV OR EQUAL RATED TO 194 DEGREE F) WITH
THE ENDS COVERED TO PREVENT WATER INTRUSION AND SEAL. PROVIDE A PIPE ESCUTCHEON AT
THE WALL.
223300 WATER HEATER
ELECTRIC WATER HEATERS:
A. PROVIDE WATER HEATER, SIZE, LOCATION AND CAPACITY AND MANUFACTURER AS INDICATED ON
THE DRAWINGS.
B. TANK TYPE ELECTRIC WATER HEATER WITH GLASS-LINED TANK RATED AT 150 PSI WORKING
PRESSURE, MAGNESIUM ANODE PROTECTION, BRONZE DRAIN VALVE, HIGH TEMPERATURE
CUT-OFF SWITCH AND IMMERSION THERMOSTAT. TANK TO HAVE A MINIMUM R-VALUE OF 10.
C. FURNISH AND INSTALL A WATTS NO. 40L, 3/4" TEMPERATURE AND PRESSURE RELIEF VALVE AND
EXTEND DISCHARGE PIPE, FULL SIZE, TO WITHIN 6" ABOVE THE MOP SINK OR FLOOR DRAIN.
D. PROVIDE AMTROL EXPANSION TANK AS SIZED ON THE DRAWINGS. EQUAL PRODUCTS BY BELL AND
GOSSETT OR ADAMSON MAY BE PROVIDED AT THE CONTRACTOR'S OPTION.
FUEL FIRED WATER HEATERS
A. FURNISH AND INSTALL HIGH EFFICIENCY, 96% THERMAL EFFICIENCY OR BETTER, GAS FIRED,
STORAGE WATER HEATER, SIZE, LOCATION AND CAPACITY AS INDICATED ON THE DRAWINGS.
B. WATER HEATER SHALL BE RHEEM RUUD WITH INTELLIGENT CONTROL SYSTEM/LCD DISPLAY.
EQUAL HEATERS BY A.O. SMITH, OR LOCHINVAR MAY BE FURNISHED AT THE CONTRACTOR'S
OPTION.
C. TANK TYPE GAS FIRED WATER HEATER WITH GLASS-LINED TANK RATED AT 150 PSI WORKING
PRESSURE, POWERED ANODES PROTECTION, BRONZE DRAIN VALVE. TANK TO HAVE A MINIMUM
R-VALUE OF 10.
D. FACTORY-INSTALLED TEMPERATURE AND PRESSURE RELIEF VALVE. EXTEND DISCHARGE PIPE,
FULL SIZE, TO WITHIN 6" ABOVE THE MOP SINK OR FLOOR DRAIN.
E. PROVIDE WATTS, POTABLE WATER EXPANSION TANK AS SIZED ON THE DRAWINGS. EQUAL
PRODUCTS BY AMTROL BELL & GOSSETT MAY BE PROVIDED AT THE CONTRACTOR'S OPTION.
224000 PLUMBING FIXTURES AND EQUIPMENT
A. WATER CLOSETS AND LAVATORIES SHALL BE VITREOUS CHINA AND SHALL ALL BE BY THE SAM
MANUFACTURER.
B. ALL WALL HUNG LAVATORIES, FLUSH VALVES, ETC., SHALL BE PER DRAWINGS AND MOUNTED AT
THE MANUFACTURER'S RECOMMENDED ROUGHING IN MEASUREMENTS, UNLESS NOTED
OTHERWISE.
C. VALVES TO BE AS FOLLOWS:
125 LB. S.W.P. GATE, GLOBE AND CHECK VALVES:
2. GATE (2-1/2" AND SMALLER) - ALL BRONZE, SCREWED, TAPERED, SOLID WEDGE DISC,
SCREWED BONNET, RISING STEM.
3. BALL (2-1/2" AND SMALLER) - ALL BRONZE, TEFLON STEM SEALS AND SEAT, 1/4 TURN
SHUT-OFF, VINYL COVERED HANDLES.
4. GLOBE (2-1/2" AND SMALLER) - ALL BRONZE, SCREWED, TAPERED, SOLID WEDGE DISC,
SCREWED BONNET, RISING STEM.
5. CHECK (2-1/2" AND SMALLER) - ALL BRONZE, SCREWED, HORIZONTAL SWING CHECK WITH
BRONZE DISC.
C. VALVES SHALL BE MILWAUKEE. EQUAL PRODUCTS BY CRANE, HAMMOND, POWELL, WALWORTH,
NORTHERN INDIANA BRASS COMPANY OR STOCKHAM MAY BE FURNISHED AT THE CONTRACTOR'S
OPTION.
D. UNIONS TO BE AS FOLLOWS:
1. UNIONS FOR COPPER PIPE TO BE 150LB., ALL BRONZE, SOLDER END TYPE BY CHASE. EQUAL
PRODUCTS BY CRANE, MUELLER OR NORTHERN INDIANA BRASS COMPANY MAY BE
FURNISHED AT THE CONTRACTOR'S OPTION.
2. DIELECTRIC UNIONS BETWEEN FERROUS AND COPPER SHALL BE INSULATED TO PREVENT
METAL-TO-METAL CONTACT AND SHALL BE MANUFACTURED BY CAPITAL MANUFACTURING
COMPANY OF COLUMBUS, OHIO. EQUAL PRODUCTS BY PATROL OR PECO SALES COMPANY.
E. CLEANOUTS TO BE AS FOLLOWS:
1. FLOOR TYPE TO BE ADJUSTABLE CAST IRON WITH NICKEL BRONZE TOP. TOP TO BE FLUSH
WITH FLOOR. SEE DRAWINGS FOR MODEL AND MANUFACTURER.
2. WALL TYPE TO BE CAST IRON TEE WITH ROUND POLISHED STAINLESS STEEL ACCESS COVER
AND THREADED PLUG. SEE DRAWINGS FOR MODEL AND MANUFACTURER.
F. FLOOR DRAINS TO BE AS FOLLOWS:
1. CAST IRON BODY SHALLOW SUMP DRAIN WITH DOUBLE DRAINAGE FLANGE AND
WEEPHOLES, FLASHING CLAMP, BOTTOM OUTLET WITH NEOPRENE GASKET INSIDE
CONNECTOR, 6" DIAMETER ADJUSTABLE GRATE. FRAME AND GRATE TO HAVE POLISHED
NICKEL-BRONZE FINISH. SEE DRAWINGS FOR MODEL AND MANUFACTURER. EQUAL PRODUCT
MAY BE SUPPLIED AT THE CONTRACTOR'S OPTION.
PLUMBING
SPECIFICATIONS
P5.0
AUTHOR
CHECKER
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
2018 INTERNATIONAL MECHANICAL CODE
2&&83$1&<&$7(*25<$5($$]
&)03(5621 &)064)7 364)7 64)7 &)0 &)0 (Y &)0 &)0
RTU-1 (Dining)
&RUULGRU
0DLQ'LQLQJ
5HVWURRPV
6<67(03238/$7,21,1&/8',1*',9(56,7<3V 0$;=S
81&255(&7('
287'225$,5
,17$.(9RX
9RX '
5S3]5D$]
6<67(0
9(17,/$7,21
()),&,(1&<
&255(&7('
287'225
$,5)/2:9RW
3529,'('
287'225
$,5)/2:
=21($,5
',675,%87,21
())(&7,9(1(66
(]
%5($7+,1*=21(
287'225$,5)/2:
9E]
9E] 5S
3]5D
$]
=21(287'225
$,5)/2:9R]
9R] 9E](]
=21(35,0$5<
$,5)/2:9S]
35,0$5<
287'225$,5
)5$&7,21=S
=S 9R]9S]
2&&83$17
',9(56,7<5$7,2
'
3(23/(
287'225$,5
5$7(5S
$5($287'225
$,55$7(5D
2&&83$1&<
'(16,7<
/$5*(67
180%(52)
3(23/(
(;3(&7('72
2&&83<7+(
=21(3]
5S
3] 5D
$]
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
HOOD DETAILS
H1.1
HALTON
HALTON
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
HOOD DETAILS
H1.2
HALTON
HALTON
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
HOOD DETAILS
H1.3
HALTON
HALTON
SP
MAXLITE
LED
MAXLITE
LED
MAXLITE
LED
EX
T
.
R
A
M
P
MA
X
L
I
T
E
LE
D
MAXLITE
LED
MA
X
L
I
T
E
LE
D
MAXLITE
LED
LCA672LCE6120
MAXLITE
LED
MAXLITE
LED
1LIGHTING PLAN
1/4" = 1'-0"
DINING
101
A- 6
A7
T2
T2
EX1B
A7
6'
P4L
P4L
EX1B
T2
T2
6'
A- 2
SWITCH E
A7
4'
T2
2'
T2
EM2B
A7
EM2B
A7
A7
8
6
2
J
J
J
#10
A7/NL
A7/NL
SWITCH C
TL1
EX1RB
T2T
T2T
T2T
T2T
T2
A7
A7 A7
A-12
SWITCH B
A6
T1 T1
P4L
P4L
SWITCH D
SWITCH C
A7/NL
T1
T1 T1
SWITCH D
K12A-2 #10
T1
A6
A-2
TL1
8
8
TL1
K12 K12
K12A-2
#10
K12K12 K12
2 A-4
J
7 A-2#10
A1
OS1 EM2WEM2W
A-17
OS1
OS OS
OS1
OS
A1
A1
A1
A1
EM2W
A1
A1
A1
A1A1
A1
5
A1/NL
A-33
SWITCH A
A1/NL
J
EM2W
4
NL
B4B4 B4
EM2W
NL
B4B4
B4
B4
EM2W
1
1
33 3
HL1HL1HL1
3
HL1
3
HL1
J
J
C-21
2
B4/NL
A-8
J
#10
NL
B4
NL
B4
NL
B4
B4
B4B4
B4
B4B4
B4
B4
OS
EM2W
A-13
B4
B4
EX1W
D
EX1RB
WP4
WB1
EX1W
OS2OS
A-11
OS2
OS
WB1
WB1
WB1
WB1
WB1
WB1
WB1WB1
K12 K12
A-2
OS2
OS
T1
T1
B4
T1
K12
A- 16
2
J
#10
EM2W
EM2W
FAMILY
103
FAMILY
102OFFICE
108
FREEZER
110
RECEIVING
112
COOLER
111
CREW
114
KITCHEN
106
DRIVE THRU
105
PAY WINDOW
113
SERVICE
104
UTILITY
116
ENTRY
100
12
/
2
2
/
2
0
1
7
4
:
0
9
:
5
0
P
M
LIGHTING PLAN
E1.1
KH
MJ
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
A-2
B1
RECESSED CAN LIGHT FIXTURE
RECESSED CAN NIGHT LIGHT FIXTURE
LED LIGHT FIXTURE
LED NIGHT LIGHT FIXTURE
HANGING LIGHT FIXTURE
MONO POINT LIGHT FIXTURE
EMERGENCY REMOTE EGRESS HEAD
CIRCUIT NUMBER
FIXTURE SYMBOL
OCCUPANCY SENSOR (WALL MOUNTED OR
CEILING MOUNTED)
SINGLE POLE WALL SWITCH AT 4'-6" A.F.F.
EMERGENCY FLOOR LIGHT (WALL MOUNTED OR
CEILING SURFACE MOUNTED)
DIMMER SWITCH, (LEVITON #IP710-DLZ-WH)
D
OS
LIGHTING LEGEND
LED TAPE LIGHT
GLOBE PENDANT LIGHT
PENDANT LIGHT
TRACK HEAD
BUILDING MOUNTED DECORATIVE LIGHT
OS
LIGHTING TRACK
A. COORDINATE WORK WITH MECHANICAL, REFRIGERATION AND EQUIPMENT CONTRACTORS,
INCLUDING COOLER/FREEZER WORK AND ICE MACHINE CONDENSING UNITS.
B. VERIFY ROUGH-IN DIMENSIONS AND POWER REQUIREMENTS WITH KITCHEN EQUIPMENT
DISTRIBUTOR PRIOR TO ROUGH-IN.
C. PROVIDE FINAL CONNECTIONS WITHIN FRONT COUNTER, COOKCENTER PANEL, REMOTE
REFRIGERATION UNITS, AND ICE MACHINE REMOTE UNIT WHEN INSTALLED BY VENDOR.
D. VERIFY AVAILABLE FAULT CURRENT AT PRIMARY SERVICE AND COMPATIBILITY WITH
MODULAR PANEL SYSTEM.
E. ENSURE ADEQUATE CONDUIT SIZE FOR ELECTRICAL AND COMMUNICATION WIRING ON SITE
AND INTO BUILDING.
F. CIRCUITS MAY BE GROUPED WITHIN COMMON CONDUITS PER NEC REQUIREMENTS UNLESS
NOTED OTHERWISE.
G. PROVIDE WALL BOX WITH 1/2" CONDUIT WITH PULLSTRING AND NYLON BUSHING STUBBED
ABOVE NEAREST ACCESSIBLE CEILING FOR THERMOSTATS, TEMPERATURE SENSORS,
CARBON DIOXIDE SENSOR, AND HUMIDISTATS UNLESS OTHERWISE NOTED.
H. WIRE ROOF TOP UNIT CONTROL CIRCUIT THROUGH AUXILIARY CONTACTS IN SMOKE
DETECTOR AND MAKE ALL FINAL CONNECTIONS. (TYPICAL OF ALL ROOF TOP UNITS)
I. COOKCENTER IS ASSEMBLED AND PREWIRED AT THE FACTORY. WIRING IS PROVIDED IN THE
PRE- INSTALLED SPLICE BOX, COILED AND TAGGED. A LENGTH OF CONDUIT WITH WIRES IS
PROVIDED FOR THE REMOTE CONDENSING ROOFTOP UNIT. RUNS POWER FROM THE SPLICE
BOX TO THE COOKCENTER PANEL.
J. ROOFTOP UNIT IS FACTORY PROVIDED WITH DISCONNECT AND UNPOWERED SERVICE
RECEPTACLE.
K. IN AREAS WITHOUT CEILINGS OR WHERE ANY CONDUITS, CONDUCTORS, FEEDERS. OR LOW-
VOLTAGE WALL EMT CONDUIT. CABLING IS VISIBLE, ALL WIRING SHALL BE IN RIGID
GALVANIZED STEEL (RGSC) OR THIN WALL EMT CONDUIT. BX, AC, AND MC CABLE ARE NOT
PERMITTED. CONDUITS ARE TO BE RUN TIGHT TO DECK EITHER PARALLEL OR
PERPENDICULAR TO BUILDING LINES AND ONLY DROP AT POINT OF CONNECTION. JUNCTION
BOXES SHALL HAVE CIRCUIT NUMBERS WRITTEN ON THE INSIDE OF THE JUNCTION BOX
COVER.
L. SEAL ROOF PENETRATIONS PER ROOFING MANUFACTURER'S INSTRUCTIONS.
M. COORDINATE WORK ABOVE THE CEILING WITH OTHER TRADES TO PROVIDE THE GREATEST
POSSIBLE CLEARANCE.CONDUITS SHALL BE ROUTED IN THE DIRECTION OF THE TRUSSES.
N. ONLY EMT CONDUITS ARE ALLOWED IN RECEIVING/DRY STORAGE.
O. DEFINITIONS: FURNISH MEANS TO SUPPLY AND DELIVER TO PROJECT SITE, READY FOR
INSTALLATION. INSTALL MEANS TO PLAN IN POSITION AND MAKE CONNECTIONS FOR SERVICE
OR USE. PROVIDE MEANS TO FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED
USE.
1. JUNCTION BOX ABOVE CEILING FOR HOOD LIGHTS AND EXHAUST HOOD.
2. PROVIDE WEATHERPROOF JUNCTION BOX AND TOGGLE TYPE 20A-1P DISCONNECT FOR
SIGNAGE. COORDINATE EXACT REQUIREMENTS WITH SIGN CONTRACTOR. VERIFY
LOCATION PRIOR TO ROUGH IN.
3. PROVIDE LAMP FOR HOOD LIGHT. SUBSTITUTION OF CFL OR INCANDESCENT LAMP IS
PROHIBITED.
4. LOCATION OF LIGHTING SWITCH BANK. REFER TO SWITCH AND HOOD SUPPRESSION
ELEVATION ON SHEET E5.2 FOR ADDITIONAL INFORMATION.
5. PROVIDE JUNCTION BOX AND SWITCH FOR ILLUMINATED MIRROR AT 4'-0" AFF AND CONNECT
TO CIRCUIT SHOWN. REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT MOUNTING
LOCATION.
6. LED TAPE LIGHTING DRIVER MUST BE INSTALLED INSIDE OF BUILDING DUE TO
TEMPERATURE RATING OF DRIVER. REFER TO LED DRIVER MOUNTING DETAIL, SHEET E5.2.
7. LIGHTS IN CANOPY PROVIDED BY CANOPY MANUFACTURER.
8. EXTERIOR LED TAPE LIGHTING 'TL1'. REFER TO ARCHITECTURAL SHEETS FOR MORE
INFORMATION. VERIFY LENGTHS AND DRIVER REQUIREMENTS PRIOR TO INSTALLATION.
REFER TO WALL PENETRATION DETAIL, SHEET E5.2.
CODED NOTES:LIGHTING GENERAL NOTES
A. CONNECT EXIT/EMERGENCY/NIGHT FIXTURES TO UNSWITCHED HOT CONDUCTOR AHEAD OF
ANY LIGHTING CONTROLS.
B. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND DETAILS FOR THE LOCATION OF
ALL LIGHTING FIXTURES AND ALL OTHER CEILING MOUNTED EQUIPMENT. VERIFY MOUNTING
HEIGHTS AND FINISHES WITH ARCHITECT PRIOR TO ROUGH-IN.
C. REFER TO THE POWER PLANS FOR LOCATION OF ELECTRICAL EQUIPMENT.
D. PROVIDE INDICATED CONDUCTOR SIZE FOR ENTIRE CIRCUIT WHERE CONDUCTOR SIZES
ARE SHOWN ON HOMERUNS.
E. PROVIDE A DEDICATED NEUTRAL WITH ALL DIMMING SYSTEM CIRCUITS. NO COMMON
NEUTRALS SHALL BE ALLOWED.
F. PROVIDE (2) ADDITIONAL #12 CONDUCTORS FOR ALL 0-10V DIMMING CIRCUITS.
1
CT CABINET
AND METER
#CODED NOTES:
1
2POWER PLAN (ENLARGED PUW)
1/2" = 1'-0"
RECEPTACLE AND COVER PLATE LEGEND
AREA RECEPTACLE
COVER RECEPTACLE USB PORTS SPECIAL NOTES
KITCHEN &
GENERAL AREA STAINLESS STEEL WHITE NO GFI AS NOTED
DEDICATED IT
CIRCUITS STAINLESS STEEL ORANGE (IG)NO CIRCUIT MARKED AS SPG OR IG
DINING ROOM BLACK BLACK YES TAMPER RESISITANT
DINING ROOM-
CUSTOMER VIEW WHITE WHITE YES TAMPER RESISITANT
JUNCTION BOX
* = A-H AS COOKLINE JUNCTION BOXES
REFER TO DETAIL #3 ON SHEET E4.2
20 AMP 120V-1PH SIMPLEX RECEPTACLE
+16" AFF OR AS NOTED
20 AMP 120V-1PH DUPLEX RECEPTACLE
+16" AFF OR AS NOTED
120V-1PH QUADRUPLEX RECEPTACLE
SPECIAL RECEPTACLE, SEE KITCHEN
EQUIPMENT SCHEDULE
20 AMP QUADRUPLEX 120V-1PH
HUBBELL # USB20X2W (QTY 2)
DISCONNECT SWITCH BY ELECTRICAL
CONTRACTOR
DATA CONNECTION
REMOTE PIEZO ALERT FROM RTU-1 &
RTU-2 SMOKE DETECTORS (96" A.F.F.)
EMERGENCY POWER KILL SWITCH (48" AFF)
120 VOLT MOMENTARY CONTACT NORMALLY
OPEN EMERGENCY OFF SWITCH, EATON
10250T WITH SHROUD. REFER SHUNT TRIP
CIRCUIT DETAIL, SHEET E3.1
REMOTE FIRE SUPPRESSION PULL STATION (48")
VOLUME CONTROL
ELECTRIC MOTOR
TELEPHONE CONNECTION
TELEPHONE/DATA CONNECTION
REMOTE TEST STATION (54")20 AMP 120V-1PH HUBBELL
#USB20X2BK RECEPTACLE PARTIAL CIRCUIT
20 AMP 120V-1PH HUBBELL #IG5362
ISOLATED GROUND RECEPTACLE
20 AMP QUAD HUBBELL #IG5362 (QTY 2)
ISOLATED GROUND RECEPTACLE
F
RT
W
VC
RT
J
THERMOSTAT, TEMPERATURE
SENSOR AND HUMIDISTAT
BY MECHANICAL CONTRACTOR
ST
S/T
ELECTRICAL LEGEND
GFI
WP
20 AMP 120V-1PH GROUND FAULT
INTERRUPTING RECEPTACLE
20 AMP 120V-1PH WEATHERPROOF
RECEPTACLE
3 15 HOME RUN TO PANEL. CIRCUIT NUMBERS,
PHASE, NEUTRAL & GROUND CONDUCTORS
INDICATED ALONG WITH ISOLATED GROUND
CONDUCTOR IF APPLICABLE.
DISCONNECT SWITCH SUPPLIED WITH
EQUIPMENT
*
R 20 AMP 120V-1PH RECESSED
RECEPTACLE
1. IN AREAS WITHOUT CEILINGS OR WHERE ANY CONDUITS, CONDUCTORS, FEEDERS.
OR LOW-VOLTAGE CABLING IS VISIBLE, ALL WRITING SHALL BE IN RIGID
GALVANIZED STEEL (RGSC) OR THIN WALL EMT CONDUIT. BX, AC, AND MC CABLE
ARE NOT PERMITTED. CONDUITS ARE TO BE RUN TIGHT TO DECK EITHER PARALLEL
OR PERPENDICULAR TO BUILDING LINES AND ONLY DROP AT POINT OF
CONNECTION. WHERE EXPOSED TO VIEW, ALL MATERIALS (CONDUITS. JUNCTION
BOXES, ETC.) SHALL BE INSTALLED IN AN ORDERLY FASHION AND SHALL BE CLEAN
AND FREE FROM ALL VISIBLE MARKING. JUNCTION BOXES SHALL HAVE CIRCUIT
NUMBERS WRITTEN ON THE INSIDE OF THE JUNCTION BOX COVER.
2. ELECTRICAL CONTRACTOR TO COORDINATE WORK WITH MECHANICAL,
REFRIGERATION AND EQUIPMENT CONTRACTORS, INCLUDING COOLER/FREEZER
WORK AND ICE MACHINE CONDENSING UNIT.
3. ELECTRICAL CONTRACTOR TO VERIFY ALL ROUGH-IN DIMENSIONS AND POWER
REQUIREMENTS WITH KITCHEN EQUIPMENT DISTRIBUTOR PRIOR TO ROUGH-IN.
4. ELECTRICAL CONTRACTOR TO HOOK UP FIELD CONNECTIONS WITHIN FRONT
COUNTER, COOKCENTER PANEL CIRCUITS, REMOTE REFRIGERATION (ON ROOF)
AND ICE MACHINE REMOTE UNIT (ON ROOF) AT TIME OF INSTALLATION.
5. GENERAL CONTRACTOR IS TO VERIFY SIZE OF FAULT CURRENT COMING OFF
PRIMARY SERVICE AND IS TO INSURE ITS COMPATIBILITY w/WENDY'S DISTRIBUTION
PANEL.
6. GENERAL CONTRACTOR IS TO INSURE ADEQUATE CONDUIT SIZE FOR ELECTRICAL
AND PHONE WIRING ON SITE AND INTO BUILDING.
7. HEIGHTS INDICATED FOR RECEPTACLES AND JUNCTION BOXES ARE MEASURED
FROM FINISH FLOOR TO THE CENTER OF THE BOX.
8. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL TELEPHONE
LINES AND TERMINATIONS. VERIFY QUANTITY AND LOCATIONS WITH OWNER PRIOR
TO BIDDING.
9. ALL CIRCUITS MAY BE CORRECTED TO THE LEAST AMOUNT OF CONDUIT RUN
UNLESS NOTED OTHERWISE.
10. ALL COVER PLATES TO BE SATIN FINISH STAINLESS STEEL IN BACK OF HOUSE
AREA. DINING AREA COVER PLATES SHALL BE WHITE UNLESS OTHERWISE NOTED.
11. ALL 120V RECEPTACLES IN KITCHEN AND RESTROOMS TO HAVE GROUND-FAULT
CIRCUIT INTERRUPTER PROTECTION PROVIDED IN ELECTRICAL PANELS.
12. COOKCENTER IS ASSEMBLED AND PREWIRED AT THE FACTORY. A LENGTH OF
CONDUIT W/WIRES IS PROVIDED FOR THE REMOTE CONDENSING ROOFTOP UNIT.
13. POWER DISCONNECT, UNPOWERED SERVICE OUTLET AND SMOKE DETECTOR ARE
PART OF ROOFTOP UNIT IF SUPPLIED BY AN APPROVED HVAC SUPPLIER.
ELECTRICIAN MUST PROVIDE WITH ALL OTHER MODELS (TYPICAL AT ALL RTU'S
UNITS).
14. THERMOSTATS, TEMPERATURE SENSORS, CARBON DIOXIDE SENSORS AND
HUMIDISTATS: UNLESS NOTED OTHERWISE, PROVIDE WALL BOX WITH 1/2"
CONDUIT STUBBED OUT TO ABOVE ACCESSIBLE CEILING WITH NYLON BUSHINGS
AND PULLSTRING.
15. MECHANICAL CONTRACTOR TO FURNISH REMOTE TEST STATION/ALARM.
ELECTRICAL CONTRACTOR TO WIRE ROOF TOP UNIT CONTROL CIRCUIT THRU
AUXILIARY CONTACTS IN SMOKE DETECTOR AND MAKE ALL FINAL CONNECTIONS.
(TYPICAL OF ALL ROOF TOP UNITS)
16. REFER TO SHEET E5.1 ELECTRICAL ELEVATIONS FOR RECEPTACLE AND COVER
PLATE LEGEND TO ENSURE PROPER RECEPTACLE TYPE, COLOR, AND COVER
PLATE.
17. ALL ROOF PENETRATIONS NEED TO BE SEALED ACCORDING TO ROOFING
MANUFACTURER'S INSTRUCTIONS.
18. COORDINATE WORK ABOVE THE CEILING WITH OTHER TRADES TO PROVIDE THE
GREATEST POSSIBLE CLEARANCE.CONDUITS SHALL BE ROUTED IN THE DIRECTION
OF THE TRUSSES.
19. ONLY EMT CONDUITS ARE ALLOWED IN RECEIVING/DRY STORAGE.
20. PROVIDE WALL BOX WITH 1/2" CONDUIT STUBBED OUT TO ABOVE ACCESSIBLE
CEILING WITH NYLON BUSHINGS AND PULLSTRING FOR ALL LOW VOLTAGE
DEVICES.
21. REFER TO SHEET E2.2 FOR DATA AND POS SYSTEM REQUIREMENTS.
GENERAL NOTES
2 E5.1 5
1
A-3
A0105
10
B-1
E5.1
A-31
N0508
16"
40"
4
16"
100"
100"
A-1
A-37
OFFICE
108
RT 15
RT
A-15
5
40"
A-35
A-21
+38"
CREW
114
B-39
14
S
+16"
+16"
13
+86"R
B-15
A-23
GFI
+60"
17
B-33
WH-1
RTU-1
WP
B-38
+16"
FAMILY
102
FAMILY
103
HALLWAY
109
UTILITY
116
+38"
A-21
+78"
C-24,26
A0801
+48"
B-23
QP0909 8"
KITCHEN
106
J
2
B-30
V0105
19
+40"
J
A-32
A-1
A-35
WPB-38
+16"
PAY
WINDOW
113
V0105
V0105
B-13
B-17
J
21
FREEZER
110
16
WPB-22
J
21
COOLER
111
RECEIVING
112
WPB-38
+16"
J
10
J
10
B-22
B-41
+72"
+38"
+38"
4
B-32
V0105
19
+40"
J
J
A-24
A-30
B-3
+36"
A-19
33"
33"
T
T
T
B-5
11
A-9
DINING
101
ENTRY
100
A-29
C-28,30
UH-1
20
J
D0201
A-3
B-24
B-21
V0105
Q0605
9
D0101
J
18
DRIVE-THRU
105
2
E2.1
D3002
K1401
C-7,9
C-1,3,5
J
C-21
J
3 L0502
L0307
5
E5.1
1
8'-9" CENTER OF GRILL RECEPTACLES.
A B E F G H
LKJ
66
54"54"
CC-25,27,29
CC-26,28,30
+65"
A-1
+65"
K0803
K0803
EP1528
D0101
C-2,4
+84"
22
J
C-6
WH-2
UTILITY
116
3
C-8,10
A0608
C-20
A1301
A-1
Q0606
B-29
A-1
B-7,9,11 Q0807
A-3
D1701
D1703
D1702
12
4
4
U0510 7
A-7
J
PAY WINDOW
A-7
J
B-31
A-3
V1503
D0101
V2201
V1801
C-39C-34
Q0608
V2201
V0702
C-36
C-37
1. MODULAR PANEL SYSTEM. SEE DETAIL #1 ON SHEET E3.1 FOR MORE INFORMATION.
2. JUNCTION BOX ABOVE CEILING FOR FOR USED COOKING OIL TANK ALARM. PROVIDE 1"
CONDUIT WITH PULL STRING FOR SUPPLIER FOR INSTALLATION OF ALARM. COORDINATE
REQUIREMENTS WITH SUPPLIER.
3. 120 VOLT NORMALLY OPEN MOMENTARY CONTACT MICROSWITCH MOUNTED IN HOOD
EXTINGUISHING SYSTEM SUCH THAT OPERATION OF EXTINGUISHING SYSTEM SHALL CAUSE
MICROSWITCH TO CLOSE (TYPICAL OF 2) REFER TO SHEET M1.1. REFER TO DETAIL 2, SHEET
E3.1.
4. RECEPTACLES PREWIRED IN MODULAR COUNTER. RUN CIRCUIT WIRING TO THE WALL AND
RUN ABOVE CEILING. COORDINATE WITH COUNTER SHOP DRAWINGS. PROVIDE 1" CONDUIT
WITH PULLSTRING FOR POS DATA BOXES.
5. PROVIDE RECEPTACLE FOR IRRIGATION SYSTEM CONTROLLER. COORDINATE REQUIREMENT
AND LOCATION WITH ARCHITECT.
6. REFER TO GRILL LINE ELEVATION DETAIL, SHEET E5.1 FOR CIRCUIT CONNECTIONS TO
PREWIRED JUNCTION BOXES IN KITCHEN EQUIPMENT SUPPLIED CHASE. REFER TO KITCHEN
EQUIPMENT CONNECTION SCHEDULE, SHEET E3.2 FOR ADDITIONAL INFORMATION.
7. PROVIDE POWER CONNECTION TO JUNCTION BOX ABOVE CEILING IN THIS AREA FOR STATIC
MENU BOARD. CONNECTION TO LED SPINNER MENU TRANSFORMER. MAKE CONNECTIONS
FROM TRANSFORMER TO (7) MENU PANELS. NO OTHER ELECTRICAL OR DATA DEVICES ARE
NEEDED FOR MENU BOARDS..
8. NOT USED.
9. ONE (1) POWER AND ONE (1) DATA 1" CONDUITS WITH PULL STRING UNDER SLAB.
COORDINATE EXACT PLACEMENT & LOCATE CONDUITS ACCORDINGLY PRIOR TO ROUGH-IN.
REFER TO ARCHITECTURAL PLANS. REFER TO DETAIL #10 ON SHEET E5.1.
10. PROVIDE POWER CONNECTION TO DOOR HEATER & EMERGENCY DOOR ALARM. REFER TO
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
11. PROVIDE RECEPTACLE FOR ICE MACHINE AND FREESTYLE MACHINE IN KITCHEN EQUIPMENT
SUPPLIED CHASE G1402. WIRE THROUGH JUNCTION BOXES SUPPLIED IN CHASE. COORDINATE
MOUNTING LOCATION WITH KITCHEN EQUIPMENT SUPPLIER.
12. MOUNT RECEPTACLE FOR BEVERAGE SCREEN IN CEILING BULKHEAD. REFER TO SERVICE
AREA ELEVATION, SHEET E5.1.
13. RECESSED RECEPTACLE FOR FLY LIGHT. COORDINATE FINAL LOCATION WITH ARCHITECT
PRIOR TO ROUGH-IN.
14. PROVIDE RECEPTACLE AT 18" AFF FOR CARBON DIOXIDE METER. PROVIDE CAT 5 CABLE BACK
TO MANAGERS OFFICE FOR REMOTE DISPLAY UNIT. COORDINATE FINAL LOCATIONS WITH
ARCHITECT. COORDINATE ALL REQUIREMENTS WITH VENDOR.
15. PROVIDE BOX AND CONDUIT RUN ABOVE CEILING FOR RTU REMOTE TEST SWITCH.
16. PROVIDE HEAT TRACE AND REQUIRED RECEPTACLE FOR CONDENSATION LINE, COORDINATE
WITH PLUMBING CONTRACTOR THE EXACT LOCATION PRIOR TO ROUGH-IN.
17. PROVIDE OUTLET FOR RE-CIRC PUMP. COORDINATE EXACT LOCATION AND REQUIREMENT
WITH PLUMBING CONTRACTOR. PLACE ON KITCHEN LIGHT CONTROL ZONE..
18. PROVIDE FLEXIBLE CONDUIT FROM FURNITURE MOUNTED POWER AND DATA OUTLET TO
JUNCTION BOX ON THE WALL FOR CUSTOMER SELF ORDER STATION, UPS AND POS.
COORDINATE EXACT LOCATION PRIOR TO ROUGH-IN..
19. MOUNT RECEPTACLE HORIZONTAL TO ENSURE CLEARANCE WITH COUNTER TOP AND BACK
SPLASH.
20. PROVIDE POWER CONNECTION TO UNIT HEATER. COORDINATE REQUIREMENTS WITH
MECHANICAL CONTRACTOR.
21. PROVIDE CONNECTION TO EVAPORATOR POWERED BY ROOF MOUNTED CONDENSER UNIT.
22. PROVIDE 60A 2-POLE 208V NON-FUSED DISCONNECT SWITCH FOR DISHWASHER WATER
HEATER. MOUNT 96" ABOVE FINISH FLOOR IN ACCESSIBLE LOCATION. COORDINATE WORK
WITH PLUMBING AND KITCHEN EQUIPMENT SUPPLIER
A- 7
8
J
DRIVE THRU
WINDOW
WF
E5.1
7
N0501
D0201
+38"
C-33
B-27
Q0406
B-35 B-37
11
D0200
E1417
Q0606
B-19
4
C-41
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
POWER PLAN
E2.1
KH
MJ
A
B
1
1IT PLAN
1/4" = 1'-0"
1. VOLUME CONTROL AT 48" A.F.F. PROVIDE 3/4" CONDUIT TO JUNCTION BOX AT MUSIC SYSTEM.
2. 2'x4'x3/4" FIRE RESISTANT PLYWOOD BACKBOARD FOR INCOMING TELEPHONE SERVICE.
3. PROVIDE (2) 1" DATA CONDUIT WITH PULL STRING TO NETWORK HUB. PROVIDE CONNECTION
TO FURNITURE MOUNTED DATA OUTLET. COORDINATE REQUIREMENT PRIOR TO ROUGH-IN.
4. ONE (1) 1" CONDUIT WITH PULL STRING IN SLAB FOR DRIVE-THRU WINDOW. COORDINATE
EXACT LOCATION PRIOR TO ROUGH-IN. REFER TO ARCHITECTURAL PLANS. REFER TO
CONDUIT IN SLAB DETAIL, SHEET E5.1.
5. ONE (1) DATA 1" CONDUITS WITH PULL STRING UNDER SLAB. COORDINATE EXACT PLACEMENT
& LOCATE CONDUITS ACCORDINGLY PRIOR TO ROUGH-IN. REFER TO ARCHITECTURAL PLANS.
REFER TO DETAIL #10 ON SHEET E5.1.
6. SOUND SPEAKER, REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHT AND
ORIENTATION. SPEAKERS CAN BE DAISY-CHAINED SPEAKER TO SPEAKER AND WIRED BACK
TO JUNCTION BOX IN MANAGER'S OFFICE.
7. RUN (1) 3/4"CONDUIT FROM SOUND SYSTEM JUNCTION BOX IN WALL IN MANAGER'S OFFICE
ABOVE CEILING TO DINING AREA (AND PATIO) FOR SPEAKERS WITH PULL STRING.
8. PROVIDE WIRING FROM TELEPHONE BOX TO DEMARCATION POINT.
9. PROVIDE CAT 5 CABLE BACK TO MANAGERS OFFICE FOR CARBON DIOXIDE METER REMOTE
DISPLAY UNIT. COORDINATE FINAL LOCATIONS WITH ARCHITECT. COORDINATE ALL
REQUIREMENTS WITH VENDOR.
10. FRONT COUNTER REGISTER DATA OUTLETS PREWIRED IN MODULAR COUNTER. PROVIDE 1"
CONDUIT WITH PULL STRING FOR POS DATA BOXES.
11. PROVIDE JUNCTION BOX WITH 1' CONDUIT WITH PULL STRING THROUGH CURB TO 2" BELOW
PAVEMENT LINE FOR CAR SENSOR DETECTOR LOOP. COORDINATE WITH CIVIL PLANS AND
COORDINATE INSTALLATION IN FIELD WITH SUPPLIER.
12. (1) 1" CONDUIT FOR DATA & (1) 1" CONDUIT FOR AUDIO AND TIMER SIGNAL UNDERGROUND TO
ORDER CONFIRMATION DISPLAY.
13. ENSURE CONDUIT STUBS ARE WITHIN THE 5"X5" OPEN AREA IN THE BOTTOM OF EACH
CANOPY SUPPORT.
14. 1" CONDUIT WITH 1-120V CIRCUIT TO PRE-SELL BOARD.
15. PROVIDE (3) 3/4" CONDUITS FOR POWER FROM ELECTRICAL PANEL (UNDERGROUND) TO MENU
BOARD WITH THREE (3) 120V CIRCUIT FOR MENUBOARD AND PRE-SELL MENUBOARD.
PROVIDE (1) 2" CONDUIT FOR DATA FROM BUILDING ABOVE CEILING TO MENUBOARD.
16. PROVIDE 1' CONDUIT WITH PULL STRING THROUGH CURB TO 2" BELOW PAVEMENT LINE FOR
DETECTOR LOOP.
17. PROVIDE 1" CONDUIT FROM ELECTRICAL PANEL A (UNDERGROUND) TO ORDER CANOPY WITH
TWO (2) 120V POWER FOR CANOPY LIGHTING AND LCD AND ONE (1) FOR OPTIONAL CANOPY
HEAT TAPE.
18.
#CODED NOTES:
A. THE CONDUITS, JUNCTION BOXES AND OUTLETS SHOWN ARE INSTALLED BY ELECTRICAL
CONTRACTOR AND ARE IN ADDITION TO THOSE INDICATED ON SHEET E2.1. ALL ITEMS SHOWN
ARE TO CLARIFY AND EMPHASIZE THE IMPORTANCE OF PROPER PLACEMENT.
B. ALL CONDUITS SHOULD BE STEEL STUBBED OUT ABOVE THE CEILING LINE AND TERMINATED
INTO A J-BOX AS NOTED AND CAPABLE OF ACCEPTING A FACEPLATE COVER.
C. ALL J-BOXES SHOULD BE INSTALLED IN SUCH A WAY THAT THEY ARE NOT BLOCKED BY OTHER
EQUIPMENT OR STRUCTURAL COMPONENTS.
D. ALL CABLE ACCESS OPENINGS THRU S/S MUST HAVE RUBBER OR PLASTIC GROMMETS
INSTALLED.
E. TELEPHONE, DATA AND CATV CABLING SHALL BE PROVIDED BY OTHERS.
F. PROVIDED NYLON BUSHINGS ON ALL CONDUITS.
G. REFER TO SHEET E1.1 FOR GENERAL ELECTRICAL NOTES.
H. MOUNT DEVICES INSTALLED ON EQUIPMENT ON NON-REMOVABLE PANEL. COORDINATE
LOCATION PRIOR TO COMMENCING ROUGH-IN WORK.
I. HEIGHTS INDICATED FOR RECEPTACLES AND JUNCTION BOXES ARE MEASURED FROM FINISH
FLOOR TO THE CENTER OF THE BOX.
LOW VOLTAGE/IT GENERAL NOTES
6
6
ENTRY
100
J
3
+65"
CHASE #3
BY KED
KITCHEN
106
DRIVE-THRU
105
E5.1
DRIVE THRU
105
J
J
11
CHASE #4
BY KED
PAY
WINDOW
113
J
+16"
11
1
N0508
E5.1 4
VC VC
40"
100"
2
8
9
+16"
100"
+16"
+16"
+16"
J
OFFICE
108
CREW
114
66
FAMILY
102
FAMILY
103
HALLWAY
109
UTILITY
116
7
10
COOLER
111
FREEZER
110
RECEIVING
112
12
14
15
16
REFER TO CIVIL
SITE SHEETS FOR
MORE INFORMATION
A-34
MENU BOARD
J
J
J
A-18
A-40
93"
D1702
D1703
D1701
D0200
D0101
+65"
+65"
5
1
3
D0201
DRIVE THRU
WINDOW
J
4
+65"
D0101
2 E5.1
5
6 E5.1
14
PRE-SELL MENU BOARD
MENU BOARD
J
J
A-14
A-42
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
LOW VOLTAGE / IT PLAN
E2.2
KH
MJ
1ROOF POWER PLAN
1/4" = 1'-0"
PHOTO CONTROLS,
MOUNT ON ROOF TO
PARAPET WALL. SEE
DETAIL 02 ON THIS
SHEET
KITCHEN ICE
MACHINE
CONDENSING
UNIT
FREESTYLE ICE
MACHINE
CONDENSING UNIT
WALK - IN COOLER
CONDENSING UNIT B-34,36
EF-3
A-26
CC-12
B-26,28
EF-2
EF-1
1
SANDWICH LINE
CONDENSING UNIT
A. REFER TO SHEET E1.1 FOR GENERAL ELECTRICAL NOTES AND SHEET E2.1 FOR ELECTRICAL
LEGEND.
B. VERIFY EXACT LOCATIONS OF HVAC AND PLUMBING EQUIPMENT, CONDUIT STUB-UPS AND
POWER CONNECTIONS PRIOR TO ROUGH-IN.
C. WIRE ROOF TOP UNIT CONTROL CIRCUIT THROUGH AUXILIARY CONTACTS IN SMOKE
DETECTOR AND MAKE ALL FINAL CONNECTIONS. (TYPICAL OF ALL ROOF TOP UNITS)
D. PROVIDE NEMA 3R DISCONNECT SWITCH IF EQUIPMENT MANUFACTURER DOES NOT PROVIDE
ONE WITH EQUIPMENT. VERIFY DISCONNECT REQUIREMENTS WITH MANUFACTURER.
E. DISCONNECTS ARE SHOWN FOR REFERENCE ONLY. ACTUAL LOCATION OF DISCONNECTS
SHALL BE COORDINATED AND VERIFIED WITH EQUIPMENT MANUFACTURER AND FINAL
ORIENTATION OF EQUIPMENT ONCE PLACED ON ROOF.
1. PROVIDE CONNECTION TO ASSOCIATED HOOD ON SWITCH. COORDINATE ALL REQUIREMENTS
WITH MECHANICAL DRAWING AND HOOD WIRING DIAGRAM PRIOR TO ROUGH-IN.
2. PROVIDE 30A 208V 3P DISCONNECT SWITCH FUSED AT 15A IN NEMA 3R ENCLOSURE. PROVIDE
(2)#10 AND (1)#10 GROUND IN 3/4" CONDUIT FROM EQUIPMENT TO REMOTE UNIT. VERIFY ALL
OTHER REQUIRED WIRING. COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER AND
MAKE ALL FINAL CONNECTIONS REQUIRED FOR PROPER OPERATION.
3. WEATHERPROOF RECEPTACLE PROVIDED WITH ROOF UNIT. PROVIDE POWER AS INDICATED.
4. PROVIDE 30A 208V 2P DISCONNECT SWITCH IN NEMA 3R ENCLOSURE FOR ICE MACHINE
CONDENSING UNITS. MAKE ALL CONNECTIONS TO ASSOCIATED UNIT PER MANUFACTURER'S
INSTRUCTIONS.
ROOF
4"
3/4" CONDUIT TO
CONTROL SECTION
OF FCLC.
SINGLE-GANG WEATHERPROOF
JUNCTION BOX MOUNTED
HORIZONTALLY WITH ROOF
SURFACE (TYPICAL).
PHOTO SENSOR PROVIDED BY FAN
CONTROL/LIGHTING CONTROL
PANEL SUPPLIER. INSTALL ON SIDE
OF PARAPET WALL FACING NORTH,
4" DOWN FROM THE TOP. INSTALL
PER MANUFACTURER'S
INSTRUCTIONS. ENSURE THAT NO
SHADOWS CAST DIRECTLY ON
PHOTOCELL.
TOP OF
PARAPET WALL
ROOF PLAN GENERAL NOTES #CODED NOTES:*HVAC MOTORS & EQUIPMENT CONNECTIONS
MARK SERVING MOCP V/P
UNIT
LOCATION
FEEDER
CO
N
D
U
C
T
O
R
S
(G
R
O
U
N
D
N
O
T
IN
C
L
U
D
E
D
)
WI
R
E
S
I
Z
E
GR
O
U
N
D
S
I
Z
E
EF-1 GRILL EXHAUST 20 208/1 ROOF 2 10 10
EF-2 FRYER EXHAUST 20 208/1 ROOF 2 10 10
EF-3 RESTROOM EXHAUST 20 120/1 ROOF
21212
DISCONNECT STARTER CONTROL
FA
C
T
O
R
Y
I
N
S
T
A
L
L
E
D
DI
S
C
O
N
N
E
C
T
WP
.
D
I
S
C
O
N
N
E
C
T
SW
I
T
C
H
ST
A
R
T
E
R
-
IN
T
E
G
R
A
L
WI
T
H
E
Q
U
I
P
M
E
N
T
LOCATION
SW
I
T
C
H
O
R
BR
E
A
K
E
R
IN
T
E
R
L
O
C
K
W/
T
H
E
R
M
O
S
T
A
T
WI
R
I
N
G
B
Y
NE
A
R
U
N
I
T
EQ
U
I
P
M
E
N
T
PA
N
E
L
RO
O
M
N
U
M
B
E
R
XEC
XEC
EC
X
X
X
CO
N
D
U
I
T
3/4"
3/4"
3/4"
X
X
X
108
108
108 X
2 PHOTOCELL CONTROL MOUNTING DETAIL
NOT TO SCALE
C-17,19 4B-14,16
4
WALK - IN FREEZER
CONDENSING UNIT
B-2,4,6
2
C- 31
RTU-1
MDP-3
RTU-2
MDP-4
WP
3
3
WP
B-8,10,12
2
TRANE - NATURAL GAS
TRANE - NATURAL GAS
80 208/3 ROOF 3 3
8
80 208/3 ROOF 3 3
8
RTU-1
RTU-2
XXX XEC
XXX XEC
1-1/4"X
X
108
1081-1/4"
WP
C- 31
3
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
ROOF POWER PLAN
E2.3
KH
MJ
NEUTRAL
SHUNT
TRIP
BREAKERS
IN 'MDP'
RED
BLACK
CIRCUIT
A-5
MICRO SWITCH
IN HOOD
POWER KILL
SWITCHES
NOT TO SCALE
SHUNT TRIP CIRCUIT DETAIL 2
SERIES RATED NOTES
MAIN BREAKERS IN MDP TO BE "FULLY" RATED TO WITHSTAND THE AVAILABLE
FAULT CURRENT AT M.D.P. OF 65,000 AMPS R.M.S.
2. THE DISTRIBUTION SYSTEM IS TO BE A "SERIES" RATED, TWO-TIER, 65/10 SYSTEM.
3. MOTOR LOAD CONTRIBUTION TO THESE PANELBOARDS SHALL NOT EXCEED 1.0%
OF THE PANELBOARD A.I.C. RATING.
4. WHERE "SERIES" RATING IS USED, PANELBOARDS AND DISTRIBUTION PANELS ARE
TO BE LEGIBLY MARKED TO INDICATE THE EQUIPMENT HAS BEEN APPLIED WITH A
"SERIES" COMBINATION RATING. LABELS CAN BE FACTORY INSTALLED OR
ENGRAVED PLASTIC-LAMINATE CARD. MARKING SHALL COMPLY WITH ARTICLE
110-22 OF N.E.C.
CONTROL ZONES
ZONE 1 KITCHEN LIGHTS & WORK LIGHTS
ZONE 2 DINING ROOM - GENERAL LIGHTS
ZONE 3 HOODS
ZONE 4 PARKING LOT LIGHTS
ZONE 5 EXTERIOR BUILDING LIGHTS/ BUILDING SIGNS/ MENU BOARDS
ZONE 6 NOT USED
ZONE 7 NOT USED
*SEE SHEET W1.1 FOR LIGHT ZONE CONTROL INFORMATION.
ARC FLASH LABELING
A. SWITCHBOARDS, PANELBOARDS AND BUSWAY SHALL HAVE A COMMERCIALLY
PRODUCED PERMANENT LABEL APPLIED, SIMILAR TO IMAGE BELOW, TO WARN OF
POTENTIAL ARC FLASH HAZARDS IN ACCORDANCE WITH NEC 110.16 AND NFPA 70E
B. LABELING MAY BE COMPLETED BY THE CONTRACTOR. THE CONTRACTOR SHALL
VERIFY THAT SWITCHBOARDS AND PANELBOARDS ARE PROPERLY LABELED IN THE
FIELD.
C. PROVIDE AND INSTALL A LABEL SIMILAR TO BELOW TO COMPLY WITH NEC 110.16
AND NFPA 70E. THE MARKING SHALL BE LOCATED SO AS TO BE CLEARLY TO
QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTMENT, SERVICING OR
MAINTENANCE OF THE EQUIPMENT. LABEL SHALL NOT BE LOCATED ON A HINGED
DOOR, OR A MOVABLE SERVICE.
PANEL
'C'
PANEL
'A'
PANEL
'B'
'COOK-
CENTER'
PANEL
PANEL
'MDP'
EXTERIOR WALL
POWER COMPANY
METER
WP C/T EQUIPMENT
CABINET
REFER TO SHEET W1.2
FOR MORE INFORMATION
ON 'FC/LC'
'LC'
LIGHTING
CONTROL
'FC'
FAN
CONTROL
CONTACT SUPPLIER FOR
SEISMIC BRACING.
SEE ARCHITECTURAL
SHEETS FOR CURB AT
SWITCHGEAR
NOTE: CONTRACTOR TO
ORDER ELECTRICAL PANEL
SYSTEM AT THE START OF
CONSTRUCTION GIVEN THE
6 WEEK LEAD TIME FOR THE
MODULAR PANEL SYSTEM.
CONTRACTOR TO PROVIDE
MECHANICAL AND
ELECTRICAL PLANS WHEN
PLACING ORDER.
SURGE PROTECTION
DEVICE
SPD
NOTE:
CONTRACTOR TO DOWNLOAD AND EXECUTE
MODULAR PANEL SYSTEM'S START UP AND
SYSTEM CHECK LIST REQUIREMENTS FROM
WENDY'S.
PANEL B OAU #1 *
208V
3PH, 3W
*SHUNT-TRIP BREAKER CONTROLLED
BY ANSUL SYSTEM. SHUTDOWN OF
POWER ON LOAD SIDE OF BREAKER
SHALL OCCUR ON ACTIVATION OF FIRE
SUPPRESSION SYSTEM OR UPON
MOMENTARY CONTACT OF
ELECTRICAL SHUT DOWN SWITCH "W"
SUB FEEDERS TO PANELS "A", "B", "C"
AND "COOKCENTER" ARE PREWIRED
AND PREINSTALLED INSIDE THE
MODULAR PANEL SYSTEM.
GND. 2/0
AWG, CU.
1
200/3
6
200/3*
SHUNT
TRIP
3
110/3*
SHUNT
TRIP
5
225/3*
SHUNT
TRIP
2/0 AWG, CU.
PANEL A
MDP
208/120V, 3 PHASE,
4 WIRE 65K AIC
PANEL
COOKCENTER*
MAIN WATER
SERVICE PIPE
REFER TO HVAC
CONNECTION
SCHEDULE IN
SHEET E3.2
C.T.
METER
800A. BUS
2
200/3
E.C. TO PROVIDE NEW WEATHERPROOF
C/T CABINET WITH 8OOA C/T IN
ACCORDANCE WITH UTILITY COMPANY
REQUIREMENTS.
60/3*
SHUNT
TRIP
PANEL C *
EC TO PROVIDE NEW 120/208V,
800A METER SOCKET IN
LANDLORD PROVIDED METER
BASE IN ACCORDANCE WITH
UTILITY COMPANY
REQUIREMENTS.
NEUT.
ISOLATED GROUND
2/0 AWG, CU.
BUILDING STEEL
2/0 AWG, CU.
#6 AWG, CU.
10'-0" COPPER
CLAD GND. ROD
G.C. AND UTILITY TO VERIFY CAPACITY OF EXISTING TRANSFORMER.
IF EXISTING TRANSFORMER ISN'T LARGE ENOUGH FOR UPGRADED
SERVICE SIZE, UTILITY TO UPGRADE TRANSFORMER.
E.C. TO PROVIDE TWO PARALLEL SETS OF
FOUR 600MCM EACH IN 4"CONDUIT
4
RTU #1 *
208V
3PH, 3W
ELECTRICAL DISTRIBUTION GENERAL NOTES
1. PANELS "A", "B" , "C" AND "COOKCENTER" SHALL BE CIRCUITED AS SHOWN.
2. THERMOSTATS TO BE PROVIDED WITH "FC/LC" FAN CONTROL/LIGHTING CONTROL PANEL ALONG WITH REMOTE SENSORS.
3. SYSTEM IS DESIGNED TO FORCE EXHAUST FANS ON WHEN ANSUL SYSTEM ACTIVATES TO MEET CODE REQUIREMENTS.
NEW PRE-PACKAGED,
PRE-WIRED
SWITCHGEAR MODULAR
PANEL SYSTEM
800/3P
MAIN CIRCUIT
BREAKER
NOT TO SCALE
ELECTRICAL ONE-LINE DIAGRAM 1NOT TO SCALE
ELECTRICAL DISTRIBUTION ELEVATION (CPI)3
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFIGFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
FI
FI
EC IS RESPONSIBLE FOR FIELD VERIFICATION OF SITE CONDITIONS AND REPORTING ANY DIFFERENCES
OR DISCREPANCIES TO ELECTRICAL ENGINEER PRIOR TO BID. NO EXTRAS OR CHANGE ORDERS SHALL BE
GIVEN FOR CONTRACTOR'S FAILURE TO VERIFY SITE CONDITIONS PRIOR TO BIDDING. UNLESS
SPECIFICALLY DETERMINED IN THE LEASE, IT IS THE RESPONSIBILITY OF THE TENANT TO INSTALL A
UTILITY OR SUB METER PER LANDLORD SPECIFICATIONS. ALL SUB METERS MUST BE FUNCTIONING
PROPERLY BEFORE TENANT OPENS FOR BUSINESS. THE TOTAL TENANT CONNECTED LOAD CANNOT
EXCEED THE LANDLORD SUPPLIED UTILITY.
ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT VOLTAGE AND
AMPERAGE REQUIREMENTS PRIOR TO FINAL CONNECTION AND REPORT ANY
DIFFERENCES TO ENGINEER. DO NOT MAKE ANY FINAL CONNECTIONS IF
VOLTAGES SHOWN ON PLANS DO NOT MATCH EQUIPMENT DELIVERED.
x ALL KITCHEN 120V, SINGLE PHASE, 15A AND 20A RECEPTACLES SHALL BE GFI TYPE PER
NEC SECTION 210.8 (B).
x ALL GFCI RECEPTACLES SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION OR A
GFCI CIRCUIT BREAKER SHALL BE USED TO FEED THE CIRCUIT NOTED.
x ALL 125V, 15A AND 20A CIRCUITS TO KITCHEN EQUIPMENT SHALL BE FED WITH A
DEDICATED NEUTRAL WIRE.
FI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
E.C. TO PROVIDE TWO PARALLEL SETS OF
FOUR 600MCM EACH IN 4"CONDUIT
FI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
GFI
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
ELECTRIC DISTRIBUTION
(GAS HEAT/GAS COOKING)
E3.1
KH
MJ
GENERAL NOTES
FIXTURE & EQUIPMENT CONNECTION SCHEDULE
SYMBOL QUANTI
TY GENERAL FIXTURE DESCRIPTION
CONNECTIONS FEEDER
REMARKS
KILOWATT
S
VOLTAGE/PHA
SE TYPE
PLUG
CORD
FURNIS
HED *
CONDU
CTORS*
*
WIRE
SIZE
GROUN
D SIZE
CONDUI
T SIZE
FRONT COUNTER - HOCKEY STICK
Q0606 1 REFRIGERATOR - FRONT COUNTER .888 120V/1PH DUPLEX RECEPTACLE ES 2 #12 #12 12"
E1417 1
FRONT COUNTER (PRE-WIRED)120V/1PH PRE-WIRED DUPLEX RECEPTACLE
BEVERAGE LINE - FREESTYLE
A0105 1
BEVERAGE SYSTEM, PUW - FREESTYLE .800 120V-1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"
A0608 1 COFFEE BREWER 2.680 120/208V-1PH L14-20R RECEPTACLE EC 3 #12 #12
12"
A1302 1 BEVERAGE DISPENSER (BUBBLER).396 120V/1PH DUPLEXRECEPTACLE EC 2 #12 #12
12"
Q0807 1 FROSTY MACHINE - DUAL HEAD 5.8A 208V/3PH L 15-30R RECEPTACLE EC 3 #8 #10 1-1/4"
(1)
SINGLE LINE COOK CENTER EP1528
E1528 1 SANDWICH STATION REFRIGERATOR .690 120V/1PH JUNCTION BOX 'A' IN CHASE #EP1528 ES 2 #12 #12
12"
E1528 1 SANDWICH STATION CONDENSING UNIT .172 120V/1PH JUNCTION BOX 'A' IN CHASE #EP1528 ES 2 #12 #12
12"
2 HMP6 WARMER .756 120V/1PH JUNCTION BOX 'B' IN CHASE #EP1528 ES 2 #12 #12
12"
V0608 1 BUN WARMER .600 120V/1PH JUNCTION BOX 'E' IN CHASE #EP1528 ES 2 #12 #12
12"
V1903 1 MPC-22 - WARMER .399 120V/1PH JUNCTION BOX 'E' IN CHASE #EP1528 ES 2 #12 #12
12"
V1902 1 MPC-1L - WARMER .110 120V/1PH JUNCTION BOX 'E' IN CHASE #EP1528 ES 2 #12 #12
12"
V0608 1 BUN WARMER .600 120V/1PH JUNCTION BOX 'E' IN CHASE #EP1528 ES 2 #12 #12
12"
D0201 1 POS TERMINAL .1 120V/1PH JUNCTION BOX 'F' IN CHASE #EP1528 ES 2 #12 #12
12"(2)
V0304 1 TOASTER 2.8 208V/1PH JUNCTION BOX 'G' IN CHASE #EP1528 ES 2 #12 #12
12"
V1902 1 MPC-1L - WARMER .110 120V/1PH JUNCTION BOX 'G' IN CHASE #EP1528 ES 2 #12 #12
12"
V1903 1 MPC-22 - WARMER .399 120V/1PH JUNCTION BOX 'G' IN CHASE #EP1528 ES 2 #12 #12
12"
V1903 1 MPC-22 - WARMER .399 120V/1PH JUNCTION BOX 'G' IN CHASE #EP1528 ES 2 #12 #12
12"
E1527 1 SALAD STATION 1.726 120V/1PH JUNCTION BOX 'H' IN CHASE #EP1528 ES 2 #12 #12
12"
K0502 1 MICROWAVE 1.726 208V/1PH JUNCTION BOX 'J' IN CHASE #EP1528 ES 2 #12 #12
12"
E1529 1 MEATWELL REFRIGERATION 1.726 120V/1PH JUNCTION BOX 'K' IN CHASE #EP1528 ES 2 #12 #12
12"
V1902 1 MPC-1L - WARMER .110 120V/1PH JUNCTION BOX 'L' IN CHASE #EP1528 ES 2 #12 #12
12"
K0803 1 GRILL - LEFT SIDE 15.9 208V/3PH SPECIAL RECEPTACLE NEMA 15-60 EC 36101 1/4"
K0803 1 GRILL - RIGHT SIDE 12.8 208V/3PH SPECIAL RECEPTACLE NEMA 15-60 EC 3 6 10 1 1/4"
K0803 1 GRILL 12.8 208V/3PH SPECIAL RECEPTACLE NEMA 15-60 EC 3 6 10 1 1/4"
KITCHEN EQUIPMENT - FRYLINE
L0502 1 EXHAUST HOOD FRYLINE 1.0 120V/1PH JUNCTION BOX MOUNTED IN THE HOOD EC 2 #12 #12
12"
J1004 1 OPEN FRYER - 4 WELL 1.0 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"
K1401 1 COMBI OVEN 6.8 208V/3PH SPECIAL RECEPTACLE NEMA 15-30 EC 3 #10 #10
3 4"
K1402 1
OVEN, HIGH SPEED 5.7 208V/1PH SPECIAL RECEPTACLE NEMA 6-30 EC 2 #10 #10
3 4"
Q0406 1 FREEZER, UPRIGHT - 1 DOOR 1.08 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"
Q0605 1 REFRIGERATOR, UNDERCOUNTER - 1
DOOR .480 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"
V0105 4 COOKER/WARMER 1.4 120V/1PH SIMPLEX RECEPTACLE EC 2 #12 #12
12"
V2201 1 FRY HOLDING MOLDULE 1.0 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"
D2201 1 FRY LINE TIMER 0.2 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"
V0702 1 FOOD WARMER, 3-LANE 0.5 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"
V1503 1 NUGGET WARMER HOLDING CABINET 1.2 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"
V1801 1 FRY STAGING WARMER 0.350 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"
Q0608 1 FREEZER, UNDERCOUNTER - 2 DOOR 0.572 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"
KITCHEN EQUIPMENT - PREP AREA / WAREWASH
A0801 1 TEA BREWER 2.704 120/208V/1PH SPECIAL RECEPTACLE L14-20P EC 3 #12 #12
12"
T2061 1 WAREWASH MACHINE 1.4 120V/1PH DUPLEX RECEPTACLE NEMA 5-20 EC 2 #12 #12
12"
WH-2 1
WATER HEATER (FOR T2061)6.0 208V/1PH WP DISCONNECT AT UNIT EC 2 #8 #10
3 4"
T2062 1 WAREWASH MACHINE W/BOOSTER 5.0 208V/1PH HARDWIRED EC 2 #10 #10
3 4"
KITCHEN EQUIPMENT - DRINK EQUIPMENT
QP0909 1 ICE MAKER WITH BIN - KITCHEN 0.4 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
3 4"
Q01##1 ICE MAKER REMOTE 1.260 208V/1PH WP DISCONNECT AT UNIT EC 3 #12 #12
3 4"
OFFICE/EMPLOYEE AND SAFETY
N0508 1 BACK OFFICE SAFE .18 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"
DINING ROOM - DRINK STAND
A0202 2 FREESTYLE BEVERAGE SYSTEM
(SELF-SERVE - DINING ROOM).800 120V/1PH DUPLEX RECEPTACLE ES 2 #12 #12
12"
QP0222 2 ICE MAKER - DINING ROOM 0.4 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
3 4"
Q01##1 ICE MAKER REMOTE 1.260 208V/1PH WP DISCONNECT AT UNIT EC 3 #12 #12
3 4"
POS SYSTEM AND KIOSK
D0101 5 POS MONITOR .1 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"(2)
D0201 4 POS MONITOR .1 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"(2)
D1701 1 CUSROMER ORDER PICK UP SCREEN .1 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"(2)
D1702 1 ORDER RUNNER SCREEN .1 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"(2)
D1703 1 BEVERAGE SCREEN .1 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"(2)
U0510 1 STATIC MENUBOARD .1 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"(2)
D1701 1 SELF ORDER STATION KIOSK .1 120V/1PH DUPLEX RECEPTACLE EC 2 #12 #12
12"(2)
A. EC - EQUIPMENT FURNISHED BY ELECTRICAL CONTRACTOR. ES - EQUIPMENT SHALL BE PREWIRED BY EQUIPMENT SUPPLIER, SUPPLIER, FIELD CONNECTIONS BY ELECTRICIAN.
B. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO KITCHEN EQUIPMENT.
C. ALL HARDWIRED CONNECTIONS TO BE MADE WITH SEAL-TIGHT FLEXIBLE METAL CONDUIT WITH INSULATED GROUND WIRE INSTALLED WITH PHASE AND NEUTRAL CONDUCTORS.
GROUND WIRE TO BE BONDED AT BOTH ENDS.
D. ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT REQUIREMENTS (INCLUDING THOSE SCHEDULED) WITH SUPPLIER PRIOR TO ROUGH-IN.
E. ALL 15A AND 20A, 120V RECEPTACLES IN KITCHEN SHALL BE GFCI PROTECTED
F. PROVIDE (2)#10 AND (1)#10 GROUND IN 3/4" CONDUIT FROM EQUIPMENT TO REMOTE UNIT. COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER AND MAKE ALL FINAL
CONNECTIONS REQUIRED FOR PROPER OPERATION.
*VERIFY QUANTITIES WITH ARCHITECTURAL EQUIPMENT PLAN AND SCHEDULE.*
REMARKS (#)
1. CORD WITH NEMA 15-30 PLUG PROVIDED BY KED.
2. DEDICATED CIRCUIT WITH ISOLATED GROUND.
3. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.
4. MOUNTING HEIGHT AS DIRECTED BY EQUIPMENT SUPPLIER.
Kitchen Equipment Schedule
E3.2
KH
MJ
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
A
B
1
'TIMELOCK' SAFE
DECAL - PART OF
MARKETING
DECALS. SUPPLIED
AND INSTALLED BY
OTHERS.
DROP BOX
N0202
SECURITY
MONITOR
'TIMELOCK'
SAFE DECAL -
PART OF
MARKETING
DECALS.
SUPPLIED AND
INSTALLED BY
OTHERS.
'TIMELOCK' SAFE DECAL -
PART OF MARKETING DECALS.
SUPPLIED AND INSTALLED BY
OTHERS.
DROP BOX
N0202
E4.1
4
'DO NOT
OPEN'
DOOR
STICKER
48" A.F.F.
(INSIDE)
E4.1
E4.1
5
2
18"
E4.1
E4.1
6
3
INSTALL NON-CONDUCTIVE 1/2"
CONDUIT WITH PULL LINE FROM
UTILITY ROOM TO J-BOX. REFER TO
DETAILS #3 & #6.
"TIMELOCK"
SAFE
DECAL
48" A.F.F.
(OUTSIDE)
SMART SAFE LOCATION
N0501
DROP BOX
N0202
OFFICE SAFE
N0508
AIM TO
VIEW
ORDERING
AREA
1SECURITY PLAN
1/4" = 1'-0"
DC
DC
DC
MD
KP
CP
AS
DB
DB
DB
OS
C1
C7
C2
C6
C5
C4
C8
WP
C11
C3
C9 C10
18"WP
MD
DR
48
"
TIME CLOCK
SECURITY
KEYPAD
48" A.F.F.
5 SECURITY KEYPAD LOCATION
NOT TO SCALE
18
"
INTERIOR ELEVATION OF COOLER/FREEZER
J-BOX WITH PULL
LINE
INTERIOR
WALL OF
WIC/WIF BOX
DOOR FROM
COOLER/FREEZER
1/2" PVC CONDUIT
NOT TO SCALE
WALK-IN PANIC BUTTON 6
INTERIOR ELEVATION
"TIMELOCK" SAFE DECAL - PART OF
MARKETING DECALS. SUPPLIED AND
INSTALLED BY OTHERS.
OF PICK-UP WINDOW
NOT TO SCALE
PUW DECALS 4
1"
COOLER CEILING
WIRING BY OTHERS
TERMINATE
CONDUIT IN J-BOX
12" CONDUIT WITH
PULL STRING
SEAL
PENETRATIONS
OF CONDUIT
WIRING BY
OTHERS
FINISHED
CEILING
GC NEED TO SEAL
INTERIOR AND EXTERIOR
CONDUIT ONCE LOW
VOLTAGE WIRING IS RUN.
NOT TO SCALE
SECURITY WIRING DETAIL 3
STOP
ALTO!
STOP
ALTO!
NO ABRIR SIN ESTAR UN GERENTE
PRESENTE Y NUNCA DESPUES
DE ANOCHECER.
DO NOT OPEN
WITHOUT MANAGER BEING
PRESENT AND NEVER AFTER DARK
5'
-
0
"
H
E
I
G
H
T
O
F
M
O
S
T
S
E
C
U
R
I
T
Y
WI
N
D
O
W
S
O
R
D
O
O
R
S
C
O
P
E
S
RED
(BACKGROUND)
WHITE (LETTERS)
DOOR CONTACTS
BACK DOOR
VIEWER
MOUNT STICKER BELOW
WINDOW OR SCOPE ON
INSIDE FACE OF REAR
DOOR EXITING STORE
NOT TO SCALE
SECURITY SIGN LOCATION 2
A. THE SAFE IS PROVIDED WITH A 3/4" DIAMETER ANCHOR HOLE IN THE BOTTOM.
ALONG WITH A LEAD SHIELD ANCHOR ASSEMBLY FOR FIELD INSTALLATION.
B. SAFE ANCHORING TO BE DONE BY LOCKSMITH.
C. THE SAFE IS TO BE ANCHORED TO THE FLOOR TO MAXIMIZE SECURITY.
D. FOR PROPER INSTALLATION FOLLOW STEPS BELOW:(ANCHOR ASSEMBLY 1/2-13
THREAD)
1. MARK THE AREA DESIRED FOR ANCHORING
2. DRILL INTO FLOOR WITH A 1" DIAMETER MASONRY BIT 1" DEEP
3. DIS-ASSEMBLE THE ANCHORING BOLT/WASHER FROM THE LEAD SHIELD
ASSEMBLY
4. TAP THE LEAD SHIELD ANCHOR IN THE FLOOR FLUSH WITH THE SURFACE
5. LOCATE AND ALIGN THE HOLE IN THE BOTTOM OF THE SAFE WITH THE LEAD
SHIELD ANCHOR IN THE FLOOR.
6. INSTALL THE FLAT WASHER/BOLT THROUGH THE BOTTOM OF THE SAFE AND
TIGHTEN SECURELY. BY DOING SO, THE SLEEVE ON THE ANCHOR ASSEMBLY
WILL SWELL, WEDGING THE ANCHOR TO THE FLOOR.
SAFE NOTES
DINING ROOM #1
FRONT COUNTER
PICK-UP WINDOW
PAY WINDOW
BACK DOOR/OFFICE
RESTROOM HALLWAY
LEVEL RECOMMENDED
LEVEL 1 THRU 3
LEVEL 2 THRU 3
LEVEL 2 & 3
LEVEL 3
LEVEL 3
CAMERAL LOCATION
C7 PATIO (IF EXISTING)
C8 EXTERIOR MENUBOARD
C9 DRIVE THRU #1
C10 DRIVE THRU #2
C11 MAIN ENTRANCE DOOR
LEVEL RECOMMENDED
LEVEL 1 THRU 3
LEVEL 1 THRU 3
LEVEL 1 THRU 3
LEVEL 1 THRU 3
LEVEL 1 THRU 3
LEVEL 1 THRU 3
CAMERAL LOCATION
C1
C2
C3
C4
C5
C6
SECURITY CAMERA LOCATION
MOUNTING NOTES
IN FRAME HEAD ON LATCH SIDE OF OPENING
CEILING MOUNT
WALL MOUNT 12" TO 18" A.F.F.
WALL MOUNT 65" A.F.F.
WALL MOUNT ABOVE DOOR
SIREN JUST ABOVE CEILING STROBE SURFACE MOUNTED ON
CEILING
SEE SAFE INSTRUCTION
BOLTED DOWN UNDER REGISTER
WALL MOUNT 8" BELOW CEILING -OR- CEILING MOUNT
POST MOUNTED TIGHT TO UNDERSIDE OF STRUCTURE
ADDITIONAL 120 VAC POWER REQUIRED
MOUNTED INSIDE UPPER CABINET IN MANAGERS
OFFICE. ADDIATIONAL 120 VAC AC POWER REQUIRED
ITEM
DOOR CONTACT
MOTION DETECTOR (360
DEGREE CEILING MOUNTED)
WALK-IN PANIC BUTTON
KEYPAD
CONTROL PANEL
SIREN / STROBE
OFFICE SAFE
DROPBOX
CAMERA
SECURITY MONITOR
DVR
MARK
BOLTED DOWN UNDER REGISTER(S)SMART SAFE
SECURITY LEGEND
DC
KP
CP
SS
OS
DB
CX
AS
MD
WP
DR
ENTRY
100
SERVICE
DINING
101
PREP. AREA
107
DRIVE THRU
105
KITCHEN
106
SERVICE
104
UTILITY
116
FAMILY
103FAMILY
102
OFFICE
108
RECEIVING
112
COOLER
111
FREEZER
110
PAY WINDOW
113
CREW
114
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
SECURITY PLAN
E4.1
KH
MJ
E FG
AB
LJK
4'
-
6
"
D0101
E1527
V1902
V1902
E1529 K0803
V1903
V0105
EP1528
NOTE:
THE COOKCENTER IS UL LISTED.
STANDARD RECEPTACLE IN COOKCENTER WITH GFI BREAKERS.
CHASES ARE PRE-WIRED. PULL WIRES TO CONNECT PANEL CIRCUITS TO
CORRESPONDING EQUIPMENT IN THE CHASE J-BOXES. REFER TO
SEPARATE FEEDS JUNCTION BOX SCHEDULE AND KITCHEN EQUIPMENT
SCHEDULE.
VERIFY CONFIGURATIONS WITH SHOP DRAWINGS.
L0307
V0608
V0403
V0601
SEPARATE FEED JUNCTIONS BOX SCHEDULE
SINGLE LINE COOK CENTER EP1528
EQ. NO.DESCRIPTION CONNECTED THROUGH CIRCUIT NO.
E1528 SANDWICH STATION REFRIGERATOR JUNCTION BOX 'A' CC-8
E1528 SANDWICH STATION CONDENSING UNIT (ROOF)JUNCTION BOX 'A' CC-12
HMP6 BUILT IN WARMER JUNCTION BOX 'B' CC-6
HMP6 BUILT IN WARMER JUNCTION BOX 'B' CC-17
V0608 BUN WARMER JUNCTION BOX 'E' CC-4
V1903 HOLDING CABINET (MPC-22)JUNCTION BOX 'E' CC-10
V1902 HOLDING CABINET (MPC-1L)JUNCTION BOX 'E' CC-22
V0608 BUN WARMER JUNCTION BOX 'E' CC-4
D0101 KITCHEN VIDEO SCREEN JUNCTION BOX 'F' A-1
V0403 TOASTER JUNCTION BOX 'G'CC-1,3
V1902 HOLDING CABINET (MPC-1L)JUNCTION BOX 'G' CC-16
V1903 HOLDING CABINET (MPC-22)JUNCTION BOX 'G' CC-18
E1527 SALAD STATION REFRIGERATION JUNCTION BOX 'H' CC-24
K0502 MICROWAVE JUNCTION BOX 'J'CC-13,15
E1529 MEATWELL REFRIGERATION JUNCTION BOX 'K' CC-2
V1902 HOLDING CABINET (MPC-1L)JUNCTION BOX 'L' CC-20
K0803 GRILL - LEFT SIDE SPECIAL RECEPTACLE NEMA 15-60 CC-25,27,29
K0803 GRILL - RIGHT SIDE SPECIAL RECEPTACLE NEMA 15-60 CC-26,28,30
5'
-
5
"
6"1'-4"3"3"
8'-9"
V1903
V1902
V1902
V1902
E1527
H
INSTALL WITH
GROUND PIN UP
K0803
6"
D0101
D0101
V1903
NOT TO SCALE
GRILL LINE ELEVATION 5
J1004
D0101
K1401
Q0406
K1402
N0501
4'
-
0
"
2'
-
6
"
1'
-
4
"
CAR DETECTOR
LOOP JUNCTION BOX
DRIVE THROUGH
POWER
6'
-
1
0
"
2'
-
3
"
A1301
A0513
A0105
Q0807
D0201
L0502
D1701
J1004
CAR DETECTOR
LOOP JUNCTION BOX
DRIVE THROUGH
POWER
1'
-
4
"
PNTITLE
SCALE
5'
-
5
"
8"8"7"8"8"
1'-2"1'-2"1'-2"2'-10"
6"
1'-4"
4"
8"
V1801
V0702
V1503
Q0608
V2201
V2201
SCALE
TITLE PN
Q0606
Q0807
D0201
D1701 D0101D1703
D1702
E1417
2'-10"
1'
-
4
"
3'
-
4
"
6'
-
1
0
"
3"
TIMER POWER
TIMER DATA
POS POWER
POS DATA
PRINTER CABLE
BOX PROVIDE 1 12"
CONDUIT TO
ABOVE CEILING.POS
DATA
POWER & DATA POS
ROUTE CIRCUIT ABOVE
CEILING
A0105
A1301
A0608
2'-8"
7'-11"
7'
-
9
"
OPEN TO
BEYOND
3'-2"1'-0"1'-9"
9'
-
3
"
7"
11"
3'-2"
4"
9'
-
0
"
3'-7"4"
OUTLET PROVIDED IN THE
MODULAR COUNTER
Q0606
1'-6"3'-2"
1" CONDUIT WITH PULL
STRING FOR DATA, AND
1" CONDUIT FOR POWER
1'
-
4
"
5'
-
5
"
11"
1'-3"
1'-7"
2'-3"
1'-11"
3'-3"
FINISH FLOOR
COORDINATOR SCREEN
POWER
COORDINATOR
SCREEN DATA
PRINTER DATA
POS POWER
POS DATA
PRINTER CABLE BOX
PROVIDE 1 12" CONDUIT
TO ABOVE CEILING.
V0105
Q0605
3'
-
6
"
PRINTER POWERD0101
2DRIVE THRU BACK COUNTER
1/2" = 1'-0"
1'
-
4
"
11"
1'-6"
2'-7"
3'-2"
4'-0"
4'-8"
3'
-
4
"
8'
-
4
"
3'-6"
11"
1'-7"
FINISH FLOOR
NETWORK HUB
DATA
SOUND SYSTEM
POWER
SOUND SYSTEM DATA
OFFICE DATA
OFFICE POWER
OFFICE DATA
OFFICE POWER
QUAD RECEPTACLE
NETWORK HUB
TELEPHONE J-BOX.
GC TO PULL TELEPHONE
WIRE FROM D-MARC TO
J-BOX.
N0508
1/2" = 1'-0"
OFFICE WALL DETAIL 4
OPEN TO
BEYOND
1'
-
4
"
8'
-
4
"
3'
-
2
"
V0105
ANSUL PULL
STATION
EMERGENCY
SHUT-FF SWITCH
USED COOKING
OIL ALARM
D0201
D0600
N0501
N0202
HEADSET HOLDER
SCALE
TITLE PN
2'-0"3'-5"1'-2"
2'-2"
1'-6"
SCALE
TITLE PN
4'
-
0
"
2'-3"
SWITCH 'E'
DIMMER SWITCH 'F'
SWITCH 'D'
UNDER HOOD
POWER KILL
BUTTON
SWITCH 'B'
SWITCH 'A'
SWITCH 'C'
SWITCH
NOTES
x ENGRAVE COVERPLATE PER
CONTROL ZONE
x DIMMER SHALL HAVE INDIVIDUAL
NEUTRAL CONDUCTOR
x DIMMER SWITCHES SHALL BE
INSTALLED PER MANUFACTURE
REQUIREMENTS
CONTROL ZONE
A SERVICE/HALLWAY
B DISPLAY LIGHTS
C TRACK LIGHTS
D MONOPOINT LIGHTS
E DINING LIGHTS
F KITCHEN LIGHTS
HOOD SYSTEM
ANSUL PULL
A0801
QP0909
3'
-
1
"
3'
-
1
"
1'
-
4
"
3'-0"2'-7"2'-1"2'-6"4'-7"
12
/
2
2
/
2
0
1
7
4
:
1
0
:
5
6
P
M
ELECTRICAL ELEVATIONS
E5.1
KH
MJ
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
EXTEND CONDUIT 6"
BEYOND FLOOR
FLOOR
SEALANT APPLIED WITHIN
ANNULUS FLUSH WITH TOP
SURFACE OF FLOOR(TYP)
1CONDUIT FLOOR PENETRATION
NOT TO SCALE
EXTEND
CONDUIT 6"
BEYOND FLOOR
FLOOR NEW CONCRETE
PATCH
NOT TO SCALE
CONDUIT IN SLAB 2
GALVANIZED
RIGID
CONDUIT
EXTEND CONDUIT
6" BEYOND WALL
CAULK AROUND BOTH END OF
SLEEVE WITH WEATHER
PROOF CAULK (TYP)
1/2" (TYP)
WALL
SEAL BOTH ENDS
OF CONDUIT ONCE
WIRE HAS BEEN
INSTALLED
3CONDUIT WALL PENETRATION
NOT TO SCALE
MOUNT LED DRIVER IN
ACCESSIBLE LOCATION AND AS
INCONSPICUOUS AS POSSIBLE
CEILING JOIST
ROOF
EXTERIOR WALL
NOT TO SCALE
LED DRIVER MOUNTING DETAIL 4
12
/
2
2
/
2
0
1
7
4
:
1
0
:
5
6
P
M
ELECTRICAL ELEVATIONS
E5.2
KH
MJ
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
260500 - COMMON WORK RESULTS FOR ELECTRICAL
A. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL NEW
COMPLETE ELECTRICAL SYSTEM AS INDICATED ON DRAWINGS, AS REQUIRED BY CODE AND AS
SPECIFIED HEREIN, IN SECTIONS 260500 THROUGH 270511.
1. TEMPORARY SERVICE AS REQUIRED.
2. PRIMARY DISTRIBUTION BY ELECTRIC COMPANY.
3. SECONDARY SERVICE AND METERING INSTALLATION BY CONTRACTOR.
4. EMERGENCY AND EXIT LIGHTING SYSTEMS.
5. TELEPHONE SYSTEM CONDUIT AND CABLES AS SHOWN ON THE DRAWINGS.
6. LIGHTING, HEATING AND POWER PANELS AND BRANCH CIRCUIT WIRING.
7. WIRING DEVICES AND PLATES.
8. INTERIOR AND EXTERIOR LIGHTING FIXTURES AND LAMPS, INSTALLATION AND WIRING.
9. LIGHTING CONTROLS.
10. CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS.
B. WORK WHICH SHALL BE PERFORMED BY OTHERS INCLUDES THE FOLLOWING:
1. FINAL CONNECTIONS OF MISCELLANEOUS EQUIPMENT BY ELECTRICAL CONTRACTOR.
2. CONTROL WIRING THAT IS FURNISHED BY OTHERS PRE-WIRED IN UNITS.
3. TELEPHONES AND FINAL CONNECTION OF WIRING THERETO.
4. INTERNAL WIRING OF EQUIPMENT FURNISHED AND PRE-WIRED BY OTHERS.
5. SECURITY SYSTEM FURNISHED AND INSTALLED BY SECURITY CONTRACTOR.
C. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY TO
INSTALL ALL OF THE 208/120 VOLT ELECTRICAL SERVICE FROM THE UTILITY COMPANY
TRANSFORMER TO THE SERVICE ENTRANCE EQUIPMENT, INCLUDING CABLES, CONDUIT, PULL
WIRE, AND GROUND ROD AND SLEEVE. CONTRACTOR SHALL COORDINATE INSTALLATION OF THE
MAIN ELECTRICAL DISCONNECT WITH THIS WORK.
D. ELECTRICAL EQUIPMENT FURNISHED BY OTHER TRADES OR BY THIS CONTRACTOR AND SPECIFIED
IN OR SHOWN ON CONTRACT DOCUMENTS SHALL BE INSTALLED AND CONNECTED BY THIS
CONTRACTOR, EXCEPT AS OTHERWISE NOTED. PROVIDE BRANCH CIRCUIT CONNECTIONS TO
ELECTRICALLY OPERATED EQUIPMENT FURNISHED BY OTHERS AS SPECIFIED IN OR SHOWN ON
THE CONTRACT DOCUMENTS. TEMPORARY WIRING FOR OTHER CONTRACTORS SHALL BE
FURNISHED AND INSTALLED BY THIS CONTRACTOR WHO SHALL BE ENTIRELY RESPONSIBLE FOR
THE SAFE AND SATISFACTORY OPERATION OF SAID TEMPORARY WIRING. COMPLY WITH LATEST
REQUIREMENTS OF OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA). PROVIDE PERSONNEL
GROUND FAULT PROTECTION ON ALL TEMPORARY POWER AND LIGHTING CIRCUITS 30 AMPERES
OR LESS. GROUND FAULT CIRCUIT INTERRUPTERS ON CONSTRUCTION CIRCUITS ARE NOT
REQUIRED WHERE CIRCUIT IS A PERMANENT CIRCUIT TO BE A PART OF THE COMPLETED
BUILDING. HOWEVER, CONTRACTOR SHALL PROVIDE APPROVED CORD SETS INCORPORATING
GFCI PROTECTION FOR PERSONNEL. REFER TO THE NEC.
E. ALL FINISH PAINTING IS TO BE PERFORMED BY GENERAL CONTRACTOR EXCEPT THAT THIS
CONTRACTOR SHALL RESTORE TO ORIGINAL CONDITION ANY PAINTING DEFACED BY THIS
CONTRACTOR AFTER ORIGINAL PAINTING.
F. ALL WORK SHALL BE DONE IN ACCORDANCE WITH:
1. NATIONAL ELECTRICAL CODE.
2. CODES: STATE, CITY AND COUNTY BUILDING CODES AND ORDINANCES.
3. NATIONAL BOARD OF FIRE UNDERWRITERS.
4. CERTAIN CODES AND STANDARDS AS SET UP BY VARIOUS TECHNICAL SOCIETIES SUCH AS
UL, NEMA, NECA, IEEE, ASTM, IES, IPCEA, AND ANSI.
5. THIS WORK SHALL BE GOVERNED ALSO BY LOCAL INSPECTOR'S REQUIREMENTS.
6. FEDERAL OCCUPATIONAL SAFETY AND HEALTH ACT STANDARDS.
7. AMERICANS WITH DISABILITIES ACT.
G. ALL PERMITS REQUIRED BY LAWS, ORDINANCES AND BUILDING CODES HAVING JURISDICTION
SHALL BE OBTAINED AT PROPER TIME BY AND AT THE EXPENSE OF THIS CONTRACTOR.
H. ALL ELECTRICAL WORK SHALL BE INSPECTED BY THE GOVERNMENTAL AGENCY HAVING
JURISDICTION, INCLUDING LOCAL INSPECTION AUTHORITIES.
I. UPON COMPLETION OF THE WORK, THIS CONTRACTOR SHALL FURNISH TO THE ARCHITECT A
CERTIFICATE OF INSPECTION AND APPROVAL FROM THE ABOVE DEPARTMENT BEFORE FINAL
PAYMENT ON CONTRACT WILL BE ALLOWED.
J. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND GROUNDING BEFORE ANY EQUIPMENT
IS CONNECTED. WHEN DIRECTED BY ARCHITECT, DEMONSTRATE BY PROPER VOLTAGE MEGGER
TEST OF INSULATION RESISTANCE OF ANY CONDUCTORS AND REPLACE ALL CONDUCTORS WHICH
FAIL SAID TESTS UNTIL ALL CONDUCTORS ARE FREE FROM INSULATION FAULTS.
K. ELECTRICAL LAYOUTS ARE SCHEMATIC. EXACT LOCATIONS ARE DETERMINED BY EXACT LOCATION
OF EQUIPMENT, ETC., AND MAY BE REVISED TO SUIT THE CONSTRUCTION CONDITIONS AND AID IN
COORDINATION WITH WORK OF OTHER CONTRACTORS.
L. ELECTRICAL DRAWINGS ARE INTENDED TO INDICATE APPROXIMATE LOCATIONS OF SWITCHES,
RECEPTACLES, LIGHTING FIXTURES AND OTHER ITEMS OF VARIOUS ELECTRICAL SYSTEMS OF
PROJECT. EXACT LOCATIONS AND ROUGH-IN DIMENSIONS FOR ALL WORK AND EQUIPMENT SHALL
BE OBTAINED FROM ARCHITECT OR OWNER AS WORK PROGRESSES. SHOULD THE ELECTRICAL
CONTRACTOR FAIL TO PROPERLY OBTAIN SUCH LOCATIONS OR DIMENSIONS, THE CONTRACTOR
SHALL REVISED THE LOCATIONS AT THE CONTRACTOR'S EXPENSE WHEN REQUESTED BY
ARCHITECT OR OWNER. ARCHITECT AND OWNER RESERVE THE RIGHT TO MAKE MINOR CHANGES
IN LOCATION OF ELECTRICAL WORK OR EQUIPMENT PRIOR TO ROUGHING IN WITH NO ADDITIONAL
COST.
M. OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ANY ITEM WHICH DO
NOT PRESENT AN ORDERLY OR REASONABLY NEAT OR WORKMANLIKE APPEARANCE, PROVIDED
THAT SUCH ITEM CAN BE PROPERLY INSTALLED IN SUCH ORDERLY WAY BY METHODS USUAL IN
SUCH WORK. ADDITIONALLY, OWNER WILL DIRECT REMOVAL AND REPLACEMENT OF ANY ITEM
WHICH DOES NOT COMPLY WITH CONTRACT DRAWINGS OR SPECIFICATIONS. SUCH REMOVALS OR
REPLACEMENTS SHALL BE AT THE SOLE DISCRETION OF THE OWNER AND SHALL BE DONE BY
CONTRACTOR, AT THE CONTRACTOR'S EXPENSE, WHEN SO DIRECTED IN WRITING BY THE OWNER.
N. THE MATERIALS AND EQUIPMENT INSTALLED IN THE WORK SHALL MEET THE REQUIREMENTS OF
THE CONTRACT DOCUMENTS AND NO MATERIALS OR EQUIPMENT SHALL BE ORDERED UNTIL
REVIEWED BY THE OWNER.
O. MANUFACTURER'S CATALOG CUTS MAY BE SUBMITTED FOR STANDARD CATALOG LIGHTING
FIXTURES AND OTHER EQUIPMENT. CATALOG CUTS MAY BE MARKED UP TO MEET THE PROJECT
SPECIFICATIONS. CUTS SHALL BE MARKED TO INDICATE MODEL NUMBER, SIZE, TYPE, COLOR,
RATING, ETC., OF THE ITEM TO BE FURNISHED.
P. PROVIDE INSTRUCTION TO OWNER'S OPERATING PERSONNEL AS NECESSARY, SHOWING
LOCATIONS AND PROPER OPERATION OF MAJOR ITEMS OF EQUIPMENT AND SYSTEM
COMPONENTS AND REFERRING TO THE OPERATING INSTRUCTION MANUAL DESCRIBED BELOW AS
A GUIDE.
Q. COMPILE TWO (2) WRITTEN MANUALS OF OPERATING INSTRUCTIONS INCLUDING COPIES OF SHOP
DRAWINGS AND A LISTING OF EQUIPMENT SUPPLIERS. ASSEMBLE IN 8-1/2" X 11" HARD BACKED
INDEXED BINDER. MATERIAL SHALL BE AS FOLLOWS:
1. TITLE PAGE: TITLE OF JOB, TENANT, ADDRESS, DATE OF SUBMISSION, CONTRACTOR, AND
ENGINEER.
2. INDEX.
3. LIST OF MAJOR EQUIPMENT USED IN PROJECT ACCOMPANIED BY CONTRACTOR PURCHASE
ORDER NUMBERS AND SUPPLIERS' NAMES AND ADDRESSES.
4. ONE COPY OF EACH SHOP DRAWING GROUPED BY TYPES OF EQUIPMENT, I.E., LIGHTING
FIXTURES, PANELBOARDS, ETC.
5. SECTION FOR EACH SYSTEM, INCLUDING:
a. BRIEF DESCRIPTION OF SYSTEM OPERATION WITH LOCATION OF MAJOR COMPONENTS.
b. LIST OF ITEMS IN SYSTEM REQUIRING PERIODIC SERVICE. REQUIRES SEPARATE SECTION
FOR EACH OF: ELECTRICAL DISTRIBUTION SYSTEM FROM THE SERVICE ENTRANCE TO
EACH LIGHTING AND POWER PANEL AND OTHER SYSTEMS (I.E. CONTROL SYSTEMS AND
ANY OTHER ELECTRICAL CONTRACTOR SYSTEM LISTED IN THESE SPECIFICATIONS.)
R. ELECTRICAL CONTRACTOR SHALL GUARANTEE HIS WORKMANSHIP AND MATERIAL FOR A PERIOD
OF ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION AND LEAVE HIS WORK IN PERFECT
ORDER AT COMPLETION.
S. SHOULD DEFECTS DEVELOP WITHIN GUARANTEE PERIOD, THIS CONTRACTOR SHALL, UPON
NOTICE OF SAME, REMEDY DEFECTS AND HAVE DAMAGES TO OTHER WORK OR FURNISHINGS
CAUSED BY DEFECTS OR WORK OR CORRECTING SAME REPAIRED AND/OR REPLACED AT HIS
EXPENSE TO CONDITION BEFORE SUCH DAMAGE.
T. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL
INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE
AS A MINIMUM THE LOCATION AND RATING OF EACH PIECE OF EQUIPMENT, GENERAL
CONFIGURATION OF WIRE AND CONDUITS INCLUDING SIZES AND ROUTING, ETC.
260519 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES
A. CONDUCTORS SHALL BE COPPER. UNLESS NOTED OTHERWISE ON THE DRAWINGS, THE MINIMUM
COPPER WIRE SIZES FOR WET AND DRY AREAS AS DEFINED BY THE NEC.
B. CONDUCTORS USED FOR EMERGENCY LIGHTING CIRCUITS SHALL BE #10 AWG, MINIMUM, AND
SHALL BE RUN IN SEPARATE CONDUIT USED FOR NO OTHER PURPOSE.
C. THE FOLLOWING COLOR CODE SHALL BE USED:
208/120 VOLT
PHASE A BLACK
PHASE B RED
PHASE C BLUE
NEUTRAL WHITE
GROUND GREEN
ISOLATED GROUND GREEN/YELLOW TRACER
260526 - GROUNDING AND BONDING
A. FURNISH AND INSTALL A COMPLETE GROUNDING SYSTEM IN COMPLIANCE WITH ALL
REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE.
B. BOND ALL STRUCTURAL STEEL TO EARTH, GROUND RODS OR PLATES, OR WATER SYSTEM AND
ISOLATED GROUND FOR IT.
C. BOND ALL ROOF MOUNTED EQUIPMENT TO NEC ACCEPTABLE GROUNDS ONLY.
D. A SEPARATE EQUIPMENT GROUNDING CONDUCTOR, MINIMUM SIZE PER NEC TABLE 250.122, SHALL
BE INSTALLED IN ALL FEEDERS, BRANCH CIRCUITS AND CONTROL CIRCUITS. CONDUCTOR
INSULATION SHALL BE GREEN.
E. CONDUIT SYSTEM SHALL BE ELECTRICALLY CONTINUOUS. ALL ENCLOSURES AND NON-CURRENT
CARRYING METALS TO BE GROUNDED. ALL LOCK NUTS MUST CUT THROUGH ENAMELED OR
PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON-CURRENT CARRYING
METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED
CLAMPS.
F. ALL RECEPTACLES SHALL BE BONDED TO A GROUND CONDUCTOR USING A #12 AWG MINIMUM
BONDING JUMPER BETWEEN RECEPTACLE TERMINAL AND GROUND CONDUCTOR.
METAL-TO-METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT
ACCEPTABLE FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES.
G. LIGHTING FIXTURES SHALL BE GROUNDED BY THE USE OF A PIGTAIL FASTENED ON BARE METAL
THAT IS FREE OF PAINT.
260533 - RACEWAY AND BOXES
A. ELECTRICAL CONDUCTORS SHALL BE ENCLOSED IN CONTINUOUS GROUNDED EMT CONDUIT
RACEWAY SYSTEM EXCEPT AS OTHERWISE NOTED.
B. RACEWAY AND ENCLOSURE SIZES SHALL BE AS SHOWN ON DRAWINGS OR, IF NOT SHOWN, SHALL
BE SIZED TO COMPLY WITH NEC FILL REQUIREMENTS FOR CONDUCTORS ENCLOSED.
C. PULL OR JUNCTION BOXES SHALL BE PROVIDED IN ALL RACEWAY SYSTEMS AT MAXIMUM OF 100
FOOT INTERVALS AND WHERE REQUIRED TO AVOID EXCESSIVE NUMBER OF BENDS, TO FACILITATE
WIRE PULLING OR TO PROVIDE ACCESS TO RACEWAY SYSTEM.
D. RACEWAYS AND ENCLOSURES SHALL BE ADEQUATELY SUPPORTED FROM BUILDING STRUCTURE
WITH APPROVED SUPPORT RODS AND/OR CLAMPS.
E. ALL CONDUIT SHALL BE RIGID HEAVYWALL GALVANIZED STEEL OR THIN WALL EMT WHERE
PERMITTED BY CODE OR AS HEREINAFTER SPECIFIED. PVC SCHEDULE 80 CONDUIT WITH RIGID
GALVANIZED STEEL ELBOWS MAY BE USED UNDER FLOOR SLAB. MINIMUM CONDUIT SIZE SHALL BE
3/4".
F. ALL CONDUIT FITTINGS SHALL BE GALVANIZED MALLEABLE IRON OR STEEL. CONNECTORS AND
COUPLINGS SHALL BE THREADED OR CUPPED SET SCREW TYPE, CONCRETE TIGHT. CONDUIT
BODIES SHALL BE MALLEABLE IRON, THREADED FOR HEAVYWALL CONDUIT AND CUPPED SET
SCREW TYPE FOR EMT, WITH CADMIUM FINISH AND CADMIUM PLATED SHEET STEEL COVERS.
SYNTHETIC RUBBER GASKETS SHALL BE USED UNDER BODY COVERS EXPOSED TO WEATHER. EMT
CONNECTORS SHALL BE INSULATED THROAT TYPE.
G. EMT THIN WALL CONDUIT MAY BE USED INSIDE HOLLOW PARTITIONS, AND ABOVE SUSPENDED
CEILINGS AND EXPOSED ABOVE 8'-0" ABOVE FINISHED FLOOR OR ABOVE PANELBOARDS. EMT
CONDUIT MAY NOT BE USED BURIED IN EARTH OR FILL, IN OR UNDER CONCRETE FLOOR OR IN
POURED CONCRETE CONSTRUCTION. PVC CONDUIT USED UNDER FLOOR SLABS SHALL HAVE
RIGID GALVANIZED STEEL ELLS AND METALLIC CONDUIT ABOVE FLOOR SLAB.
H. CONDUIT SHALL GENERALLY BE CONCEALED WHERE POSSIBLE. NO CONDUIT SHALL BE RUN IN
SLAB, EXCEPT AS REQUIRED FOR FLOOR-MOUNTED DEVICES.
I. EXPOSED CONDUIT WILL BE PERMITTED IN ELECTRIC ROOMS, AND SIMILAR UNFINISHED SPACES,
OVERHEAD IN AREAS WITHOUT CEILINGS AND ELSEWHERE AT THE DISCRETION OF THE OWNER.
J. DURING ROUGHING-IN, CAP ALL CONDUITS WHICH MAY BECOME FOULED WITH FOREIGN MATERIAL.
1. FLEXIBLE CONDUIT SHALL BE USED FOR "MAKEUP" CONNECTIONS TO VIBRATING
EQUIPMENT, MOTORS, AND AS OTHERWISE NECESSARY OR PERMITTED BY CODE. LIGHTING
FIXTURES MAY BE SUPPLIED WITH SHORT LENGTHS (MAX. 6'-0") OF FLEXIBLE CONDUIT.
GROUNDING SHALL BE GREEN GROUNDING CONDUCTOR AS SPECIFIED IN "GROUNDING".
2. FLEXIBLE CONDUIT SHALL BE UL APPROVED 1/2" MINIMUM TRADE SIZE.
3. LIQUID-TIGHT FLEXIBLE CONDUIT AND LIQUID-TIGHT FITTINGS SHALL BE USED IN AREAS
EXPOSED TO THE WEATHER OR EXCESSIVE MOISTURE.
K. NO MORE THAN FOUR (4) 90-DEGREE BENDS WILL BE ALLOWED IN ANY ONE CONDUIT RUN. WHERE
MORE BENDS ARE NECESSARY IN ANY SINGLE RUN, A PULL BOX SHALL BE INSTALLED. PULL BOXES
SHALL ALSO BE INSTALLED IN LONG RUNS AT A MAXIMUM SEPARATION OF 100'-0". ALL CONDUIT
EXCEPT IN CONCRETE SLAB OR EARTH SHALL BE ROUTED PARALLEL OR PERPENDICULAR TO THE
LINES OF THE BUILDING, AND NO OUT-OF-PLUMB OR DIAGONAL LINES WILL BE ACCEPTED.
L. OUTLETS SHALL BE PROVIDED FOR DEVICES, LIGHTING FIXTURES, MOTORS AND
EQUIPMENT CONNECTIONS, SYSTEMS EQUIPMENT CONNECTIONS, SPECIAL OUTLETS, AND
AS OTHERWISE REQUIRED.
260553 - IDENTIFICATION
A. PROVIDE NAMEPLATES ON THE FOLLOWING EQUIPMENT:
B. NAMEPLATES SHALL INDICATE FUNCTION OF EACH DEVICE. NAMEPLATES SHALL BE LAMINATED
PHENOLIC WITH A WHITE SURFACE AND BLACK CORE. USE 1/16" THICK MATERIAL FOR PLATES UP
TO 2" X 4". FOR LARGER SIZES, USE 1/8" THICK MATERIAL.
C. LETTERING SHALL BE CONDENSED GOTHIC. THE SPACE BETWEEN LINES SHALL BE EQUAL TO THE
WIDTH OF THE LETTERS. USE 1/4" MINIMUM HEIGHT LETTERS WHICH OCCUPY FOUR TO THE INCH.
INCREASE LETTER SIZE TO 3/4" ON LARGER PLATES.
D. FASTEN NAMEPLATES TO EQUIPMENT USING ADHESIVE MATERIAL THAT IS INTENDED FOR USE ON
ENAMELED SURFACES. ADHESIVE SHALL BE NON_AGING FOR AN APPLICATION AND USAGE
TEMPERATURE RANGE OF 0 TO 50 DEGREES CELSIUS.
262416 - PANELBOARDS
A. INSTALL MODULAR SWITCHGEAR WHICH INCLUDES PANELBOARDS WITH ALL CIRCUIT BREAKERS,
PLUS CONTROL SYSTEMS FOR HOODS, HVAC AND LIGHTING AS SHOWN ON THE DRAWINGS.
SUBSTITUTIONS OF LOOSE PANELS INSTEAD OF MODULAR SWITCHGEAR IS NOT ALLOWED.
MODULAR SWITCHGEAR SHALL BE LISTED/LABLED BY A RECOGNIZED TESTING LABORATORY.
B. MODULAR SWITCHGEAR SHALL BE PURCHASED FROM ONE OF THE 'SUPPLIER LIST' COMPANIES
(REFER TO ARCHITECTURAL DRAWINGS). NO SUBSTITUTIONS ARE ALLOWED. THIS CONTRACTOR
MUST VERIFY ALL REQUIREMENTS OF MODULAR SWITCHGEAR WITH SUPPLIER PRIOR TO
ORDERING. AT MINIMUM, THIS CONTRACTOR SHALL VERIFY THE FOLLOWING:
1. ANY BREAKER MODIFICATIONS (AMPACITY, NUMBER OF POLES, CONTROL, RATINGS, GFCI,
HACR, SWITCHING DUTY, SHUNT TRIP, ETC.).
2. RELOCATION OF ANY CIRCUITS.
3. AIC RATING REQUIRED, AFTER COORDINATING THIS WITH THE LOCAL UTILITY COMPANY.
4. HVAC (RTU AND HOOD FANS) CONTROL PACKAGE INCLUDED.
5. ANY OTHER SITE SPECIFIC MODIFICATIONS.
C. CIRCUIT BREAKERS SHALL BE QUICK MAKE, QUICK BREAK, BOLT ON, THERMAL MAGNETIC TRIP
(ENCLOSURE COMPENSATED), MOLDED CASE TYPE, UL LISTED. 15 AND 20 AMP SINGLE POLE
BREAKERS SHALL CARRY THE UL "SWD" MARKING.
D. REFER TO PANEL SCHEDULES ON PLANS FOR ADDITIONAL INFORMATION.
E. THIS CONTRACTOR SHALL PROVIDE A TYPED CIRCUIT DIRECTORY CARD MOUNTED IN A FRAME
WITH A CLEAR PLASTIC PROTECTIVE COVER ON INSIDE OF PANEL DOORS.
262713 - ELECTRICAL SERVICE AND METERING
A.METERING EQUIPMENT SHALL BE FURNISHED BY ELECTRICAL UTILITY COMPANY, AND INSTALLED
BY THIS CONTRACTOR. COORDINATE WITH ELECTRIC COMPANY. EQUIPMENT SHALL BE INSTALLED
AS INDICATED IN ONE-LINE DIAGRAM ON THE DRAWINGS.
262726 - WIRING DEVICES
A. FURNISH AND INSTALL WIRING DEVICES, INCLUDING SWITCHES, RECEPTACLES AND POWER
RECEPTACLES, TELEPHONE OUTLET BOXES, COVERPLATES AND BLANK OUTLET PLATES AS
SHOWN OR DESCRIBED ON DRAWINGS. WIRING DEVICES SHALL BE HUBBELL OR EQUIVALENT
PREMIUM SPECIFICATION GRADE AS MANUFACTURED BY BRYANT, EAGLE, SLATER, PASS &
SEYMOUR, OR LEVITON. COLOR SHALL BE AS DIRECTED BY ARCHITECT OR OWNER.
B. RECESSED OUTLET BOXES SHALL BE STAMPED STEEL SUITABLE FOR THE DEVICE INSTALLED.
C. SURFACE MOUNTED OUTLET BOXES SHALL BE CAST IRON SUITABLE FOR THE DEVICE INSTALLED.
D. DUPLEX RECEPTACLES SHALL BE A MINIMUM OF 20 AMPERE RATING.
E. COVERPLATES SHALL BE PLASTIC UNLESS OTHERWISE NOTED. COLOR SHALL BE AS DIRECTED BY
ARCHITECT OR OWNER.
F. COVERPLATES FOR SURFACE MOUNTED BOXES SHALL BE STAMPED STEEL SUITABLE FOR THE
PARTICULAR BOX AND DEVICE CONFIGURATION.
G. WIRING DEVICES UNLESS OTHERWISE PROPERLY AUTHORIZED, SHALL BE SAME MANUFACTURERS
ONLY; NO ADDITIONAL MANUFACTURERS SHALL BE PERMITTED UNLESS SPECIFICALLY
AUTHORIZED BY THE OWNER.
H. LOW VOLTAGE CONTROL DEVICES SHALL BE AS NOTED ON DRAWINGS OR AS REQUIRED.
I. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL MOTOR CONTROLS, INCLUDING STARTERS,
SAFETY DEVICES AND REMOTE CONTROL STATIONS, UNLESS FURNISHED BY EQUIPMENT
MANUFACTURER IN PRE-WIRED ASSEMBLIES.
J. FURNISH AND INSTALL CONTACTORS, CONTROL RELAYS, PUSHBUTTON STATIONS, SELECTOR
SWITCHES, PILOT LIGHTS, FUSES AND SIMILAR CONTROL AUXILIARIES AS SHOWN ON DRAWINGS
AND/OR REQUIRED TO PROVIDE PROPER CONTROL AND ISOLATION BETWEEN VARIOUS
AUTOMATIC CONTROLLERS AND EQUIPMENT SHOWN ON THE DRAWINGS.
K. ALL CIRCUIT BREAKERS FEEDING MOTOR LOADS SHALL BE HACR TYPE.
L. EQUIPMENT SHALL BE SAME MAKE AS MOTOR STARTERS. PUSHBUTTON STATIONS, SELECTOR
SWITCHES, PILOT LIGHTS: HEAVY DUTY, OIL TIGHT, STANDARD SIZE, WITH TRANSFORMER TYPE
PILOT LIGHTS, FLUSH MOUNTED WHERE PRACTICAL.
M. ANY ACCESS PANELS REQUIRED BUT NOT SPECIFIED OR SHOWN ON DRAWINGS SHALL BE
FURNISHED BY THIS CONTRACTOR WITH DESIGN TO BE APPROVED BY ARCHITECT BEFORE
INSTALLATION.
262813 - FUSES
A. ALL FUSES SHALL BE BUSSMANN, SIZES AS NOTED ON DRAWINGS.
B. ALL FUSES SHALL BE UL LISTED, CURRENT-LIMITING TYPE, MINIMUM 200,000 AMPS INTERRUPTING
CAPACITY.
C. FUSES 1 AMP AND ABOVE SHALL BE BUSSMANN "LOW PEAK" RK-1. 250 VOLT FUSES SHALL BE USED
ON 208/120 VOLT SYSTEMS.
D. CONTROL FUSES FOR MOTOR STARTERS, CONTACTORS, AND CONTROL PANEL TRANSFORMERS
SHALL BE BUSSMANN FNQ-R SIZED AT 500% RATED CURRENT.
E. FURNISH SPARE FUSES TO THE OWNER IN THE FOLLOWING QUANTITIES: 10% OF TOTAL PROJECT
QUANTITY (BUT NOT LESS THAN THREE (3) FOR EACH TYPE AND RATING OF FUSES).
F. TYPED LIST OF ALL SPARES SHALL ALSO BE INCLUDED.
262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS
A. DISCONNECT SWITCHES SHALL BE HEAVY-DUTY TYPE, UL LISTED.
B. ALL SWITCHES SHALL HAVE SWITCH BLADES WHICH ARE FULLY VISIBLE IN THE "OFF" POSITION
WHEN THE SWITCH DOOR IS OPEN. SWITCHES SHALL HAVE REMOVABLE ARC SUPPRESSORS
WHERE NECESSARY TO PERMIT EASY ACCESS TO LINE SIDE LUGS. LUGS SHALL BE FRONT
REMOVABLE AND UL LISTED FOR 75 DEGREES C., ALUMINUM OR COPPER WIRES.
C. SWITCHES SHALL BE QUICK-MAKE, QUICK-BREAK. THE OPERATING HANDLE SHALL BE AN INTEGRAL
PART OF THE BOX, NOT THE COVER. PROVISIONS FOR PADLOCKING THE SWITCH IN THE "OFF"
POSITION WITH AT LEAST THREE LOCKS SHALL BE PROVIDED. SWITCHES SHALL HAVE A DUAL
COVER INTERLOCK TO PREVENT UNAUTHORIZED OPENING OF THE SWITCH DOOR WHEN THE
HANDLE IS IN THE "ON" POSITION, AND TO PREVENT CLOSING OF THE SWITCH MECHANISM WITH
THE DOOR OPEN. THE HANDLE POSITION SHALL INDICATE WHETHER THE SWITCH IS "ON" OR "OFF".
D. SWITCHES SHALL BE FURNISHED IN NEMA 1 GENERAL PURPOSE ENCLOSURE EXCEPT ALL
SWITCHES LOCATED OUTDOORS SHALL BE NEMA 3R WEATHERPROOF (WP). NEMA 3R ENCLOSURE
SHALL BE MANUFACTURED FROM GALVANIZED STEEL. ENCLOSURES SHALL HAVE A GRAY BAKED
ENAMEL FINISH, ELECTRODEPOSITED, ON CLEANED, PHOSPHATIZED STEEL.
E. SWITCHES SHALL BE RATED FOR AC. FUSIBLE SWITCHES MUST ACCEPT CLASS R FUSES AND HAVE
PROVISIONS TO REJECT ALL FUSES EXCEPT CLASS R. THE UL LISTED SHORT CIRCUIT RATING OF
THE SWITCHES SHALL BE 200,000 RMS SYMMETRICAL AMPERES WHEN CLASS R FUSES ARE USED.
265100 - INTERIOR LIGHTING
A. INSTALL LIGHTING FIXTURES AS SHOWN ON THE DRAWINGS.
B. ALL FIXTURES SHALL BE LISTED AND LABELED BY UNDERWRITERS LABORATORIES AND ENERGY
STAR AND/OR DLC LISTING.
C. FIXTURES ARE TO BE PROVIDED COMPLETE WITH END AND TRIM PLATES AND ALL MOUNTING
ACCESSORIES REQUIRED FOR A COMPLETE FIXTURE INSTALLATION.
D. USE STEEL WIRE HANGERS FASTENED TO THE BUILDING STRUCTURE TO SUPPORT RECESSED
FIXTURES AT EACH CORNER. (FOUR-CORNER SUSPENDED). FIXTURES TO FIT TIGHT AGAINST
CONSTRUCTION TO ELIMINATE LIGHT LEAKS.
E. WALL-MOUNTED FIXTURES SHALL BE MOUNTED PLUMB WITH BUILDING LINES AND
INSTALLED WITH LIGHTING CONTROL PROPER BOX AND COVER HARDWARE.
F. SURFACE-MOUNTED FIXTURES SHALL COVER MOUNTING HARDWARE. USE A CANOPY THAT IS NO
LONGER THAN THE LENGTH AND WIDTH OF THE FIXTURE AND AT A HEIGHT THAT IS NO HIGHER
THAN REQUIRED TO MOUNT FIXTURE ABSOLUTELY VERTICAL. CANOPY FINISH SHALL MATCH
FIXTURE FINISH.
G. STEM-MOUNTED FIXTURES SHALL BE MOUNTED SO AS TO BE ABSOLUTELY VERTICAL AND
HORIZONTAL. INSTALL AND SUPPORT AS SHOWN ON DRAWINGS.
270510 - TELEPHONE CONDUIT SYSTEM
A. CONDUIT FOR TELEPHONE WALL OUTLETS SHALL BE A MINIMUM OF 3/4" UNLESS NOTED
OTHERWISE.
B. TELEPHONE OUTLET BOXES SHALL BE SINGLE GANG. PLATES SHALL BE FURNISHED AND
INSTALLED BY THIS CONTRACTOR.
C. FURNISH AND INSTALL A 3/4" THICK TELEPHONE BACKBOARD AT LOCATION SHOWN ON THE
DRAWINGS. THE PLYWOOD BACKBOARD SHALL BE SECURELY ATTACHED TO THE BUILDING WALLS
TO SUPPORT RELAY PANELS, TERMINAL BLOCKS AND OTHER HARDWARE WEIGHING
APPROXIMATELY 10 POUNDS PER SQUARE FOOT. PRIME AND PAINT THE BACKBOARD SIDES AND
EDGES WITH TWO COATS OF GRAY FLAMEPROOF PAINT.
D. CONDUIT SYSTEM SHALL BE CONTINUOUS FROM OUTLETS TO TELEPHONE BACKBOARD. INSTALL
PULL STRING IN EMPTY CONDUITS.
E. INSTALL #6 GROUND WIRE FROM TELEPHONE BACKBOARD TO SERVICE ENTRANCE GROUND PER
TELEPHONE COMPANY'S REQUIREMENTS.
270511 - IT INSTALLATION
A. THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING AND UNDERSTANDING WENDY'S
REQUIREMENTS AND FORMS TO ENSURE A TIMELY INSTALLATION OF IT EQUIPMENT. THE
CONTRACTOR SHALL COMPLETE, SIGN, AND RETURN THE IT READINESS FORM AS REQUIRED.
B. THE FOLLOWING ARE THE SITE READINESS MINIMUM REQUIREMENTS.
1. THE INSTALLATION OF ALL KITCHEN EQUIPMENT IS COMPLETE.
2. THE BUILDING HAS PERMANENT POWER.
3. ALL ISOLATED GROUND (IG RECEPTACLES) ARE INSTALLED AND ENERGIZED.
4. THE FRONT COUNTERS ARE COMPLETE AND ENERGIZED.
6. INTERIOR WALLS ARE COMPLETED FOR KIOSKS. ELECTRICAL EQUIP IS INSTALLED &
OPERATIONAL.
7. ELECTRICAL IS INSTALLED AND ENERGIZED & WALLS ARE COMPLETED & READY FOR
QUEUING BOARDS.
8. DRIVE THRU LOOPS ARE INSTALLED TO HME'S SPECIFICATIONS.
9. BUN WARMERS ARE INSTALLED.
10. MWS CART IS ONSITE.
11. HME LOOPS (DRIVE THRU LOOPS) ARE VISIBLE.
C. THE CONTRACTOR SHALL COORDINATE WITH WENDY'S CONSTRUCTION MANAGER, WENDY'S IT
MANAGER, AND WENDY'S IT INSTALLATION CONTRACTOR TO SCHEDULE THE INSTALLATION IN A
TIMELY MANNER.
ELECTRICAL SPECIFICATIONS
12
/
2
2
/
2
0
1
7
4
:
1
3
:
5
2
P
M
79
6
M
e
r
u
s
C
o
u
r
t
St
.
L
o
u
i
s
,
M
O
6
3
0
2
6
T
6
3
6
.
3
4
9
.
1
6
0
0
F
6
3
6
.
3
4
9
.
1
7
3
0
CE
R
T
I
F
I
C
A
T
E
O
F
A
U
T
H
O
R
I
T
Y
N
O
.
3
8
0
0
8/18/2021
SEAL
DESCRIPTIONDATEREV.
ISSUE DATE: 08/17/2021
PROJECT NUMBER: 21-008
DRAWN BY:
CHECKED BY:
SHEET NAME
SHEET NUMBER
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
ELECTRICAL
SPECIFICATIONS
E6.1
KH
MJ
DIVISION 1 - GENERAL SPECIFICATIONS
(OMITTED)
DIVISION 3 - CONCRETE
FOOTINGS
SLABS AND FOOTINGS
SIDEWALKS AND RAMPS
PAVING
CONCRETE PADS
CONCRETE PAD - WALK IN BOX - COOLER / FREEZER / DRY STORAGE
DIVISION 4 - MASONRY
GENERAL
CMU
MORTAR FOR FACE BRICK
FACE BRICK
DIVISION 6 - WOOD, PLASTICS, AND COMPOSITES
ROUGH CARPENTRY
STRUCTURAL LUMBER
FINISH CARPENTRY
SOLID SURFACING MATERIAL
BUILDING WEATHER BARRIER
DIVISION 7 - THERMAL AND MOISTURE PROTECTION
BUILDING INSULATION
ROOFING INSULATION
GENERAL ROOFING
ROOFING HANDLING
ROOFING STORAGE
ROOFING OVERNIGHT COVER
ROOFING AND SHEET METAL
ROOFING SURFACE PREPARATION
ROOFING WOOD DECKS
ROOFING MEMBRANE
FLASHING
ROOFING PERIMETER LAPS
ROOFING PROJECT / SITE CLEAN-UP
ROOFING INSPECTIONS
ROOFING CONTRACTOR QUALIFICATION ASSURANCE
ROOF METAL TRIMS
SEALANT
SEALANT MATERIALS
KNOTWOOD
DIVISION 8 - OPENINGS
ALUMINUM ENTRANCE DOORS AND STOREFRONT & CURTAINWALL
GLAZING
STEEL SERVICE DOORS AND FRAMES
PREFINISHED DOORS
PICK-UP WINDOW
ACCESS DOOR
WALL LOUVER
DIVISION 9 - FINISHES
FLOOR AND WALL TILE INSTALLATION
GYPSUM DRYWALL
SUSPENDED CEILING SYSTEM
NON-TILE FIBERGLASS REINFORCED POLYESTER (FRP) PANELS
PAINTING
PAINT SCHEDULE
PATIO CONCRETE SLAB
DIVISION 10 - SPECIALTIES
EXTERIOR TRASH ENCLOSURE
GENERAL SIGNAGE
ROOM IDENTIFICATION SIGN
RESTROOM IDENTIFICATION SIGN
PUBLIC RESTROOM ACCESSORIES
WALL DECOR
HEIGHT WARNING DEVICE
ORDER STATION CANOPY
SMOKELESS SNUFFER
STAINLESS STEEL CORNERS
KITCHEN EQUIPMENT
HOOD FIRE SUPPRESSION SYSTEM AND PORTABLE FIRE EXTINGUISHERS
FIRE EXTINGUISHER CABINETS
WALK-IN COOLER/FREEZER/DRY STORAGE (PRE-FABRICATED)
WALK-IN COOLER/FREEZER/DRY STORAGE (FIELD ERECTED)
COMMUNICATION SYSTEM
A.
B.
C.
A.
B.
C.
D.
1.
A.
B.
A.
A.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
DIVISION 3 - CONCRETE
NOTE: FURNISH LABOR, MATERIALS AND EQUIPMENT NECESSARY TO COMPLETE
CONCRETE WORK INCLUDING EXCAVATION, TRENCHING, FORM WORK, REINFORCING,
CEMENT FINISH AND PRECAST CONCRETE.
FOOTINGS
REFER TO DRAWINGS FOR SIZES, DEPTHS, AND REINFORCEMENT. EARTH TRENCH
WILL BE PERMITTED FOR FOOTINGS IF CONDITIONS ARE FAVORABLE. SIDES OF
TRENCHES SHALL BE CLEAN, EVEN, VERTICAL AND TRUE, AND BOTTOMS SHALL BE
LEVEL, CLEAN AND WITHOUT FILL.
BREINFORCING SHALL BE UNPAINTED AND UNCOATED, FREE FROM RUST OR
SCALE, AND SHALL BE CLEANED AND STRAIGHTENED BEFORE BEING SHAPED AND
PLACED IN POSITION, ACCURATELY POSITION REINFORCEMENT AND SECURED
AGAINST DISPLACEMENT, WHERE THERE IS DELAY IN POURING, RE-INSPECT
REINFORCEMENT AND CLEAN OFF ANY DRIED CEMENT, MORTAR OR RUST.
REINFORCEMENT SHALL BE OF SIZE AND SPACING AS NOTED ON THE DRAWINGS
OR AS PER LOCAL CODES.
SLABS AND FOOTINGS
REFER TO DRAWINGS FOR CONCRETE STRENGTH, THICKNESS AND REINFORCING.
1. ALTERNATE: "FIBERMESH" OR EQUAL, A 100% HOMOPOLYMER VIRGIN
POLYPROPYLENE FIBRILLATED FIBERS CONTAINING NO REPROCESSED OLEFIN
MATERIALS AND ARE SPECIFICALLY ENGINEERED AND MANUFACTURED TO AN
OPTIMUM GRADUATION FOR USE AS FIBROUS REINFORCEMENT FOR
CONCRETE.
PROVIDE CONTINUOUS 6 MIL 'VISQUEEN' VAPOR BARRIER ON LEVEL 4" GRAVEL
BASE UNDER BUILDING SLABS. LAP EDGES 6" AND SEAL (TURN UP AT WALLS).
POUR CONCRETE FLOORS LEVEL, EXCEPT WHERE FLOOR DRAINS OCCUR, IN
WHICH CASE THEY SHALL HAVE A 36" TO 48" RADIUS SLOPED TO DRAIN. TOTAL
SLOPE IS NOT TO EXCEED 3/4" BELOW FLOOR LEVEL.
SECURE AND BUILD INTO CONCRETE WORK THE FOLLOWING MATERIALS:
PLUMBING AND SYRUP LINES, ELECTRIC CONDUIT, CONCRETE INSERTS,
HANGERS, ANCHORS, FLOOR CLIPS, SLEEVES FOR PIPING, ETC., AND WHEN
REQUIRED FOR ANCHOR BOLTS, PLATES, ETC., FOR EQUIPMENT.
SIDEWALKS AND RAMPS
3,000 PSI AIR ENTRAINED CONCRETE, 4" THICK, BROOM FINISH SCORE WITH 3/4"
DEEP CONTRACTION JOINTS INTO APPROXIMATELY 4'-0" SQUARES AS SHOWN ON
DETAIL ON THE FOUNDATION PLAN.
SIDEWALKS AND RAMPS TO MEET LOCAL CODES ALONG WITH REQUIRED SLOPES
AND CROSS SLOPES IN THE AMERICANS WITH DISABILITIES ACT FOR ACCESSIBLE
DESIGN.
PAVING
SPECIFICATIONS FOR CONCRETE PAVING REQUIRED TO BE VERIFIED BY OWNER'S
CONSTRUCTION ENGINEER.
CONCRETE PADS
CONCRETE PADS AT PICK-UP WINDOW, ORDER STATION AND TRASH ENCLOSURE
(REFER TO SITE PLAN): COLOR TREATED AS NOTED IN EXTERIOR FINISHES
SCHEDULE ON DRAWINGS. A TRIAL SLAB SHALL BE MADE, USING THE SAME
MATERIALS THAT ARE TO BE USED ON THE JOB TO ASSURE OWNER ACCEPTANCE.
CONCRETE PAD - WALK IN BOX - COOLER / FREEZER / DRY STORAGE
A. A LEVEL CONCRETE PAD IS REQUIRED FOR THE WALK IN BOX. THE PAD CAN NOT
DEVIATE MORE THAN 1/4" OVER 10' IN ANY DRIECTION.
B. A SQUARE CONCRETE PAD IS REQUIRED FOR THE WALK IN BOX. THE PAD CAN NOT
DEVIATE MORE THAN 1/2" ON DIAGONAL MEASUREMENTS.
C. A MINIMUM OF 6" OF CONCRETE IS REQUIRED AROUND THE PERIMETER OF THE
WALK IN BOX. NO CONTROL JOINTS ARE ALLOWED IN THE SLAB FOR THE WALK IN
BOX.
DIVISION 4 - MASONRY
NOTE: FURNISH LABOR, MATERIALS AND EQUIPMENT NECESSARY TO COMPLETE
MASONRY WORK INCLUDING STRUCTURAL STEEL, WALL TIES, MASONRY
REINFORCING , ETC.
GENERAL
WORK TO BE LAID TRUE TO DIMENSIONS, PLUMB, SQUARE, AND IN BOND AND
PROPERLY ANCHORED. COURSES SHALL BE LEVEL WITH JOINTS OF UNIFORM
WIDTH, NO JOINTS SHALL EXCEED SPECIFIED SIZE, AND IF NECESSARY, CLIPPED
COURSES SHALL BE PROVIDED TO LEVEL OFF.
PERFORM MASONRY WORK IN ACCORDANCE WITH ESTABLISHED TRADE
PRACTICES. BRACE "GREEN" WALLS AND PROTECT MORTAR FROM "WASHING-OUT"
AT END OF DAYS WORK USING PLANKS, WEIGHTED CANVAS, OR SIMILAR MEANS TO
COVER WALL. COOPERATE WITH OTHER TRADES IN JOINTLY EXECUTED WORK AND
BUILT-IN ITEMS. PATCH OPENINGS AS REQUIRED FOR PASSAGE OF MECHANICAL
AND ELECTRICAL WORK. "UNCORED" UNITS MUST BE USED AT ALL EXPOSED AND
OR SEMI-EXPOSED CONDITIONS OF BRICK ROWLOCK CAPS, SILLS, ETC. SIZE AND
LOCATION SHOWN ON CONSTRUCTION DOCUMENTS.
LINTELS SHALL BE OF SIZE AND SHAPE AS SHOWN OR NOTED ON THE DRAWINGS
AND SHALL BE STRUCTURALLY SOUND FOR THE SPANS AND LOADS INVOLVED.
COORDINATE INSTALLATION OF OTHERS WORK ITEMS, SUCH AS ANGLES, ANCHOR
BOLTS, FLASHING, STEEL LINTELS AND FRAMING, VENTS, SLEEVES, DOOR FRAMES,
MISCELLANEOUS STEEL WORK WITH ANCHORS, ETC.
CMU TO BE LAID IN A RUNNING BOND.
CMU TO BE LAID WITH FULL MORTAR IN THE BED AND HEAD JOINTS.
1. CONCAVE TOOLED JOINT USING A TOOL OF LARGER THAN 1/2" DIAMETER..
FLASHING TO BE PLASTIC COATED ALUMINUM BY HOHMANN & BARNARD, OR THIN
COATED COPPER BY YORK FLASHING. THE FLASHING SHOULD PENETRATE THE
BRICKWORK AND BE TRIMMED AT THE COMPLETION OF THE MASONRY WORK.
CLEAN AND POINT CONCRETE BLOCK WORK AT END OF EACH WORKING DAY. AT
THE COMPLETION OF WORK AS AN ENTIRETY.
CMU: ASTM C90, MEDIMUM WEIGHT.
REFER TO STRUCTURAL DWGS. FOR MORE INFORMATION.
A.
A.
B.
C.
D.
A.
A.
A.
A.
A.
A.
B.
ROOFING INSULATION
WHERE NOTED ON PLAN, INSULATION SHALL BE INSTALLED IN THE FOLLOWING
MANNER:
1. MECHANICALLY FASTENED - THE ROOF INSULATION BOARDS SHALL BE
INSTALLED WITH FACTORY APPROVED FASTENERS AND STRESS DISTRIBUTION
PLATES. LENGTH WILL VARY TO MEET THE JOB CONDITIONS. MINIMUM
FASTENER PENETRATION THROUGH THE ROOF DECK PER MANUFACTURER'S
RECOMMENDATIONS. CUT SCREWS AND PAINT TO MATCH SURROUNDING
CONDITIONS.
2. GLUE DOWN -THE ROOF INSULATION BOARDS SHALL BE INSTALLED WITH
FACTORY APPROVED ADHESIVES. COVERAGE RATES PER MANUFACTURER'S
RECOMMENDATIONS.
GENERAL ROOFING
COMPONENTS OF THE MANUFACTURERS ROOFING SYSTEM SHALL BE PRODUCTS
OF THAT MANUFACTURER. SUBSTITUTES OF THEIR RELATED MATERIALS MUST
HAVE PRIOR ACCEPTANCE BY THE MANUFACTURER.
DEVIATION FROM MANUFACTURERS SPECIFICATIONS AND INSTALLATION
INSTRUCTIONS SHALL VOID WARRANTY ISSUANCE UNLESS THE DEVIATION IS
APPROVED BY A DULY AUTHORIZED REPRESENTATIVE OF THE MANUFACTURER IN
WRITING.
SHOP DRAWINGS ARE REQUIRED FOR ORDERING, MANUFACTURING, AND FINAL
INSPECTION OF THE ROOFING SYSTEM. SHOP DRAWINGS SHALL INCLUDE ROOF
OUTLINE, SIZE, ROOF PENETRATIONS, INSULATION TYPE AND THICKNESS, PIECE
LAYOUT AND PARAPET LOCATION. ORDERS AND SHOP DRAWINGS SHALL BE
APPROVED BY ROOFING MANUFACTURER AND ASSIGNED A MANUFACTURER
NUMBER.
WARRANTY: MANUFACTURERS STANDARD 15 YEAR, NO DOLLAR LIMIT WARRANTY.
ROOFING DELIVERY
ROOFING AND RELATED MATERIALS SHALL BE DELIVERED TO JOB SITE IN ORIGINAL
PACKAGING WITH SHIPPING LABELS INTACT. IF SHORTAGES OR DAMAGES ARE
DISCOVERED UPON DELIVERY, DO NOT ACCEPT THEM UNTIL THE FREIGHT AGENT
MAKES A DAMAGED OR SHORT NOTATION ON YOUR FREIGHT BILL. IN CASE OF
CONCEALED LOSS OR DAMAGE, IT IS NECESSARY TO NOTIFY YOUR FREIGHT
AGENT AT ONCE.
ROOFING HANDLING
THERE SHALL BE ADEQUATE PERSONNEL AND EQUIPMENT TO LIFT ROOFING
MATERIAL FOR PLACEMENT ON THE ROOF TO PREVENT DAMAGE TO MATERIAL.
THE MATERIAL SHALL BE DEPOSITED ON THE ROOF NEAR THE ENDS OF JOISTS OR
OTHER ROOF LOAD BEARING MEMBERS OF THE BUILDING FRAME AND
CONVENIENTLY LOCATED FOR FINAL PLACEMENT.
ROOFING STORAGE
ROOFING MATERIAL SHALL BE STORED IN ORIGINAL PACKAGING TO PROTECT
MEMBRANE FROM GETTING WET OR BEING DAMAGED AND SOILED. ADHESIVES
AND SEALANTS SHALL BE PROPERLY STORED AND PROTECTED AS RECOMMENDED
BY THEIR MANUFACTURERS.
ROOFING OVERNIGHT COVER
A TEMPORARY WATER SEAL SHALL BE PERFORMED EACH NIGHT TO AVOID WATER
PENETRATING UNDERNEATH THE INSTALLED MEMBRANE AND CAUSING DAMAGE
TO THE BUILDING AND THE INSULATION BEING USED.
1. INSTALLATION: WITH THE MEMBRANE EXTENDED OVER EXPOSED INSULATION
(IF USED), SET INTO A WATER RESISTANT, NON-BITUMINOUS SEALANT,
GENEROUSLY APPLIED OVER A DUST, GREASE, AND MOISTURE FREE
SUBSTRATE. FASTEN 12" ON CENTER USING TERMINATION BAR.
ROOFING AND SHEET METAL
FURNISH AND COMPLETELY INSTALL THE ROOFING SYSTEM PER OWNER'S
APPROVED SUPPLIER SPECIFICATIONS AND DIAGRAMS AS OUTLINED AND
FURNISHED BY THE SUPPLIER. THE ROOFING SYSTEM SHALL BE INSTALLED
EXCLUSIVELY BY A OWNER'S APPROVED MANUFACTURER INSTALLER. FINAL
INSPECTION PRIOR TO WARRANTY ISSUANCE SHALL BE PERFORMED BY AN
AUTHORIZED QUALITY CONTROL FIELD INSPECTOR AS PER CURRENT
SPECIFICATIONS, INSTALLATION AND INSPECTION POLICIES.
ROOFING SURFACE PREPARATION
THE ROOF SHALL HAVE AN ADEQUATELY PREPARED SURFACE TO RECEIVE THE
INSULATION, ROOFING AND FLASHING. PRIOR TO ONSET OF WORK, THE
APPLICATOR SHALL INSPECT THE ENTIRE AREA TO BE ROOFED, AND DEFECTS AND
IMPROPER CONDITIONS AFFECTING THE ROOF INSTALLATION SHALL BE
CORRECTED BEFORE APPLICATION OF THE INSULATION.
NSTALL 1/2" DENS-DECK PRIME ROOF BOARD OVER RIGID INSULATION PRIOR TO
MEMBRANE INSTALLATION.
A.
B.
C.
D.
A.
A.
A.
A.
A.
A.
B.
A.
B.
C.
D.
E.
F.
FLASHING
FLASHING ON PARAPET WALLS SHALL BE FASTENED 12" ON CENTER ALONG
BOTTOM ON MAIN DECK WITH A MINIMUM 6" LAP WELDABLE TO DECK MEMBRANE,
COVERING APPROVED FASTENERS. PARAPET WALLS SHALL BE COVERED
MINIMUM OF 12" HIGH.
PROVIDE AND INSTALL FLASHING FOR PARAPET WALLS AND WALK IN BOX. (FINISH
AS NOTED ON EXTERIOR ELEVATIONS AND SCHEDULES.)
FLASH AND COUNTER-FLASH ITEMS THAT PASS THROUGH THE ROOF PROVIDE
"PITCH POCKETS" AS REQUIRED TO FORM A COMPLETE JOB.
PROVIDE NECESSARY MOUNTING CLIPS, CLOSURES, FASTENINGS, ETC., REQUIRED
TO COMPLETE THE COUNTER-FLASHING, GRAVEL STOPS, CAPS AND COPINGS,
INDICATED ON THE DRAWINGS.
ROOFING PERIMETER LAPS
ANY TIME A ROOF EDGE DOES NOT HAVE A PARAPET WALL OR ROOF TIE-IN, (I.E.
DRIP EDGE, WATER/GRAVEL STOP, TERMINATION BAR ON EDGE, GUTTER, ETC.)
THEN THE ROOF SECTION MUST HAVE A LAP 27" IN FROM THE EDGE AND
REVERSED. THIS HELPS REDUCE WIND UP-LIFT AROUND PERIMETERS AND
REVERSING THE LAP, ALLOWS CONTRACTOR APPLICATOR TO PLACE ROOF
SECTION AWAY FROM THE EDGE.
ROOFING PROJECT/SITE CLEAN-UP
UPON COMPLETION, THE ROOFING CONTRACTOR SHALL REMOVE RUBBISH,
WASTE MATERIALS, ETC. FROM THE ROOF, LEAVING THE ROOF IN A CLEAN
CONDITION AND FURTHER REMOVING SUCH ROOFING DEBRIS FROM THE WORK
SITE. A RIGOROUS INSPECTION FOR WATERTIGHT FIELD SEAMS SHALL BE MADE
AFTER COMPLETION OF JOB.
ROOFING INSPECTIONS
UPON COMPLETION OF EACH ROOFING JOB, CONTRACTOR SHALL FILL OUT
INSPECTION CARD AND RETURN TO MANUFACTURER. EACH ROOF SHALL BE
INSPECTED BY AN AUTHORIZED QUALITY CONTROL FIELD INSPECTOR TO MAKE
SURE APPLICATION MEETS MANUFACTURERS SPECIFICATIONS, BEFORE ISSUANCE
OF WARRANTY. CONTRACTOR SHALL ACCOMPANY INSPECTOR ON INSPECTIONS
AND OBTAIN SIGNED WARRANTY FROM CUSTOMER AND RETURN TO
MANUFACTURER, WITH NO FINAL PAYMENT BEING MADE UNTIL AN OWNER'S
REPRESENTATIVE HAS WARRANTY.
ROOFING CONTRACTOR QUALIFICATION ASSURANCE
THE ROOFING CONTRACTOR SHALL BE DULY CERTIFIED BY ROOFING
MANUFACTURER FOR COMPLETE APPLICATION AND INSTALLATION OF THIS
ROOFING SYSTEM. TO MAINTAIN ROOF WARRANTY, FUTURE REPAIRS AND
ALTERATIONS SHALL BE MADE BY PERSONNEL DULY CERTIFIED BY ROOFING
MANUFACTURER.
ROOF METAL TRIMS
THIS SECTION INCLUDES METAL TRIM AT PARAPET CAPS, WALL CAPS, BREAK
METAL TRIMS, AND THE BOTTOM TRIM ON THE FASCIAS. TRIM MATERIAL SHALL
CONSIST OF PREFINISHED (REFER TO FINISH SCHEDULE FOR COLOR), .040"
ALUMINUM SHEETS OR 24 GA. GALVALUME STEEL, FORMED TO THE PROFILES
SHOWN ON THE DRAWINGS. ATTACHMENT TO THE SUB STRUCTURE SHALL BE BY
NON-FERROUS FASTENERS THAT ARE CONCEALED FROM VIEW WHERE POSSIBLE.
FASTENERS NOT CONCEALED FROM VIEW MUST MATCH THE COLOR OF THE TRIM
BEING FASTENED.
SEALANT
SURFACES TO RECEIVE SEALANT ARE TO BE DRY AND THOROUGHLY CLEANED OF
LOOSE PARTICLES OF DIRT AND DUST, OIL, GREASE, OR OTHER FOREIGN MATTER.
SEAL AT EXTERIOR DOOR FRAMES, WINDOW FRAMES, AND OPENINGS FOR
PLUMBING, ELECTRICAL REFRIGERANT AND GAS LINES IN EXTERIOR WALLS,
FLOORS AND ROOFS.
SEALANT MATERIALS
JOINT LOCATIONS AND JOINT SEALANT TYPES ARE NOTES ON DRAWINGS.
ACCEPTABLE MANUFACTURER/TYPE PER EACH JOINT TREATMENT TYPE IS AS
FOLLOWS:
(JS-1) POLYSULFIDE POLYMER BASE COMPOUND SHALL CONFORM TO AMERICAN
STANDARD SPECIFICATION A-116 , 1960 CLASS A OR B, AND EQUAL TO THAT
MANUFACTURED BY SONNEBORN OR PECORA.
(JS-2) BYTYL SEALANT SHALL BE BUTYL RUBBER BASE COMPOUND EQUAL TO THAT
MANUFACTURED BY SONNEBORN OR PECORA.
(JS-3) LATEX JOINT SEALANT. ACRYLIC LATEX OR SILICONE LATEX., ASTM C834,
TYPE OP, GRADE NF. EQUAL TO THAT MANUFACTURED BY BOSTIK, INC., PECORA
OR TREMCO.
(JS-4) SINGLE-COMPONENT, PURABLE, MOISTURE CURING POLYURETHANE JOINT
SEALANT: ASTM C920, TYPE S, GRADE P, CLASS 100/50. EQUAL TO THAT
MANUFACTURED BY PECORA, TREMCO OR GE.
(JS-5) SINGLE-COMPONENT, MILDEW RESISTANT, NEUTRAL CURING SILICONE JOINT
SEALANT: ASTM C920, TYPE S, GRADE NS, CLASS 25. EQUAL TO THAT
MANUFACTURED BY PECORA, TREMCO OR GE.
INDEX TO SPECIFICATIONS
KNOTWOOD
ALUMINUM SIDING, SOFFITS, AND ACCESSORIES
GENERAL
SECTION INCLUDES
A. ALUMINUM SIDING.
B. ALUMINUM SOFFITS.
C. ALUMINUM TRIM AND ACCESSORIES.
D. 88MM SHUTTER BLADE.
E. FIXED ROUTED LOUVER SECTIONS.
F. 65MM SLAT.
G. SMALL INFILL.
RELATED SECTIONS
A. COLD-FORMED METAL FRAMING: METAL FRAMING
FOR SUPPORT OF ALUMINUM SOFFITS.
B. ROUGH CARPENTRY: WOOD STUD FRAMING,
FURRING AND SHEATHING FOR SUPPORT OF ALUMINUM SOFFITS.
C. BUILDING INSULATION: RIGID THERMAL INSULATION
INSTALLED BEHIND SIDING.
D. FLASHING AND SHEET METAL: SHEET METAL
GUTTERS AND DOWNSPOUTS.
E. JOINT SEALANTS: SEALANTS USED IN CONJUNCTION WITH
ALUMINUM SIDING INSTALLATION.
DELIVERY, STORAGE, AND HANDLING
A. PACKAGE AND STORE PRODUCTS UNDER COVER IN MANUFACTURER'S
UNOPENED PACKAGING UNTIL READY FOR TRANSPORT AND
INSTALLATION.
B. PROTECT PANELS FROM ACCELERATED WEATHERING BY REMOVING OR
VENTING SHEET PLASTIC SHIPPING WRAP.
C. STORE PREFINISHED MATERIAL OFF GROUND PROTECTED FROM
WEATHER, TO PREVENT TWISTING, BENDING, OR ABRASION, AND PROVIDE
VENTILATION. SLOP METAL SHEETS TO ENSURE DRAINAGE.
D. PREVENT CONTACT WITH MATERIALS CAPABLE OF CAUSING
DISCOLORATION OR STAINING.
PROJECT CONDITIONS
A. MAINTAIN ENVIRONMENTAL CONDITIONS (TEMPERATURE, HUMIDITY, AND
VENTILATION) WITHIN LIMITS RECOMMENDED BY MANUFACTURER FOR
OPTIMUM RESULTS. DO NOT FABRICATE PRODUCTS UNDER
ENVIRONMENTAL CONDITIONS OUTSIDE MANUFACTURER'S ABSOLUTE
LIMITS.
COORDINATION
A. COORDINATE WORK WITH INSTALLATION OF WINDOWS, LOUVERS, AND
ADJACENT COMPONENTS OR MATERIALS.
WARRANTY
A. KNOTWOOD'S LIMITED LIFETIME WARRANTY AGAINST CRACKING, PEELING
AND GLOSS/COLOR RETENTION WITHIN THE GUIDELINES STATED BY THE
AMERICAN ALUMINUM MANUFACTURERS ASSOCIATION (AAMA).
1. STANDARD COLORS
a. DULUX DURATEC - AAMA 2604 (5 YEAR FLORIDA) 15 YEAR
MANUFACTURER'S WARRANTY.
b. DULUX FLUOROSET - AAMA 2605 (10 YEAR FLORIDA) 20 YEAR
MANUFACTURER'S WARRANTY.
2. WOOD GRAINS
a. AMMA 2064 (5 YEAR FLORIDA) 15 YEAR MANUFACTURER'S
WARRANTY.
PRODUCTS
MANUFACTURERS
A. ACCEPTABLE MANUFACTURER: KNOTWOOD LLC. , WHICH IS LOCATED AT:
10914 NE 39TH STREET SUITE B-3
VANCOUVER, WA 98682: INFO AT HYPERLINK
"MAILTO:SALES@KNOTWOOD.COM"SALES@KNOTWOOD.COM WEB:
HYPERLINK "HTTP://WWW.KNOTWOOD.COM"WWW.KNOTWOOD.COM ;
B. SUBSTITUTIONS: NOT PERMITTED
MATERIALS
A. EXTRUDED ALUMINUM SIDING AND SOFFITS: KNOTWOOD WOOD GRAIN
ALUMINUM SIDING AND SOFFITS WITH ALLUMINATE BONDED FILM
FINISH IS EXTRUDED ALUMINUM.
EXDC90- 3-3/4" X 5/8" X 18'6" CLADDING BOARD SMOOTH
EXDC100R- 4" X 5/8" X 18'6" CLADDING BOARD RIBBED
EXDC100S- 4" 5/8" X 18'6" CLADDING BOARD SMOOTH
EXDC150- 6" X 5/8" X 18'6" CLADDING BOARD SMOOTH
EXSM3816- 1-1/2" X 5/8" X 18'6" SELF MATING SLAT (2-PART)
EXSM6516- 2-1/2" X 5/8 X 18'6" SELF MATING SLAT (2-PART)
EXSM10016- 4" X 5/8" X 18'6" SELF MATING SLAT (2-PART)
ESM15016- 6" X 5/8" X 18'6" SELF MATING SLAT (2-PART)
B. EXTRUDED ALUMINUM VENTED SOFFIT: KNOTWOOD WOOD GRAIN
ALUMINUM VENTED SOFFITS WITH ALLUMINATE BONDED FILM FINISH IS
EXTRUDED ALUMINUM.
KWCV150- 6" X 5/8" X 18'6" CLADDING VENTED BOARD
C. EXTRUDED ALUMINUM ACCESSORIES AND TRIM: KNOTWOOD WOOD
GRAIN ALUMINUM TRIM AND ACCESSORIES WITH ALLUMINATE BONDED
FILM FINISH IS EXTRUDED ALUMINUM.
EXDCST- STARTER PIECE FOR CLADDING AND DECKING 18'6"
KWCFB- CLADDING FLASHING BASE 16'4" (USED WITH
KWCFTCL OR KWCFTCS)
KWCFTCL- CLADDING TOP CLIP 16'4"
KWCFTCS- CLADDING TOP BLIP SMALL 16'4"
KWCBJ- CLADDING BOTTOM JOINER 16'4" (USED WITH KWCTJ)
KWCTJ- CLADDING TOP JOINER 16'4"
KWCTF- CLADDING WINDOW AND DOOR TOP FLASHING 16'4"
KWCIEFC- CLADDING INTERNAL/EXTERNAL FEMALE CORNER 16'4"
KWCIEMC- CLADDING INTERNAL/EXTERNAL MALE CORNER 16'4"
D. EXTRUDED ALUMINUM SHUTTER BLADE, SLAT, SMALL INFILL, AND FIXED
LOUVER SECTIONS: KNOTWOOD WOOD GRAIN ALUMINUM TRIM AND
ACCESSORIES WITH ALLUMINATE BONDED FILM FINISH IS EXTRUDED
ALUMINUM.
EXS88- 3-7/16" (88MM) X 18'6" SHUTTER BLADE.
EXS6516- 2-1/2" X 5/8" X 18'6" SLAT
EXINFS- SMALL INFILL LENGTH: 18'6"
KWRF65L- ROUTERED LOUVER FRAME LEFT TO FIT 2-1/2" SLAT
LENGTH: 17'8"
KWRF65R- ROUTERED LOUVER FRAME RIGHT TO FIT 2-1/2" SLAT
LENGTH: 17'8"
KWRF65M- ROUTERED LOUVER FRAME MID-RAIL TO 2-1/2" SLAT
LENGTH: 17'8"
KWRF88L- ROUTERED LOUVER FRAME LEFT TO FIT EXS88 LENGTH: 17'8"
KWRF88R- ROUTERED LOUVER FRAME RIGHT TO FIT EXS88 LENGTH: 17'8"
KWRF88M- ROUTERED LOUVER FRAME MID-RAIL TO FIT EXS88 LENGTH:
17'8"
KWRF- ROUTERED TOP BOTTOM FRAME LENGTH: 17'8"
FINISHES
A. PRETREATMENT: E-CLPS CHROME FREE FIVE STAGER ALUMINUM
PRETREATMENT SYSTEM. COMPLIES WITH, AAMA 2604, AND AAMA 2605
SUPERIOR PERFORMANCE STANDARD AND MEETS EPA, OSHA, STATE AND
LOCAL ENVIRONMENTAL REQUIREMENTS AND CONTAINS NO CHROMATES,
CYANIDES, OR OTHER HEAVY METALS. WASTE TREATMENT IS USUALLY A
SIMPLE PH NEUTRALIZATION AND DISPOSAL TO THE SANITARY SEWER.
B. DULUX GROUP MANNEX BASE COAT AND DURATEC SERIES
ELECTROSTATIC APPLIED ARCHITECTURAL POWDER COATINGS ARE
APPROVED TO AAMA 2604 PERFORMANCE STANDARD.
1. GLOSS LEVEL: STANDARD GLOSS IS 30 PERCENT, PLUS OR MINUS 5
PERCENT.
C. SUPER DURABLE POWDER COATINGS: ALLUMINATE PREMIUM WOOD
FINISHES USE A POLYURETHANE POWDER COAT WITH INK BASED WOOD
GRAIN PATTERNS SUBLIMATED INTO THE BASE POWDER EFFECTIVELY
TATTOOING THE POWDER. THE COMBINED EFFECT CREATES ALL THE
AESTHETIC ASPECTS OF REAL WOOD WHILE OFFERING THE SAME
ENVIRONMENTAL ADVANTAGES OF POWDER COATED FINISHES.
1. WOOD GRAINED
a. LIGHT OAK
FABRICATION
A. PREPARE SURFACES, PRE-TREAT AND COAT COMPONENTS IN
ACCORDANCE WITH AAMA 2604 AND 2605 QUALITY STANDARDS AND
APPLICABLE EUROPEAN STANDARDS FOR THE COATING MATERIAL
SPECIFIED.
B. WRAP AND PACKAGE COATED COMPONENTS USING METHODS SUITABLE
FOR TRANSIT AND COVERED SITE STORAGE WITHOUT DAMAGE.
A.
B.
C.
A.
A.
B.
A.
B.
DIVISION 6 - WOOD, PLASTICS, AND COMPOSITES
FURNISH LABOR, TOOLS, EQUIPMENT AND MATERIALS TO COMPLETE WORK UNDER
THIS HEADING AS INDICATED ON THE DRAWINGS AND DESCRIBED IN THE
SPECIFICATIONS.
ROUGH CARPENTRY
PROVIDE AND MAINTAIN TEMPORARY ENCLOSURES, AND BARRICADES AS
REQUIRED BY GOVERNING LOCAL ORDINANCES.
PROVIDE TEMPORARY DOOR AND WINDOW ENCLOSURES AS REQUIRED.
HEADERS TO BE SIZED AS DETAILED IN THE STRUCTURAL DRAWINGS.
STRUCTURAL LUMBER
REFER TO STRUCTURAL DRAWINGS FOR INFORMATION ON STRUCTURAL LUMBER,
SHEATHING, PRE-FABRICATED WOOD JOISTS, FASTENING AND ATTACHMENT.
FINISH CARPENTRY
FURNISH LABOR AND MATERIALS TO COMPLETE WORK UNDER THIS SECTION AS
INDICATED ON DRAWINGS AND DESCRIBED IN THESE SPECIFICATIONS.
HARDWARE DIMENSIONS ARE TO BE NET SIZE AND NOT NOMINAL SIZE. MATERIAL
FOR INTERIOR FINISH SHALL BE AS FOLLOWS:
1. DINING ROOM TRIM - REFER TO FINISH SCHEDULE & DETAILED DRAWINGS.
2. COUNTERTOPS TO BE FURNISHED AND INSTALLED BY KITCHEN EQUIPMENT
SUPPLIER.
SOLID SURFACING MATERIAL
VANITY TOPS AND WINDOW SILLS: DUPONT CORIAN, COLORS AS NOTED ON
DRAWINGS.
PROVIDE IN THICKNESS, FINISH AND EDGE TREATMENT AS REQUIRED AND
COORDINATED WITH THE OWNER'S REPRESENTATIVE.
A.
A.
B.
ROOFING WOOD DECKS
ROOF SHALL BE CLEAN, SMOOTH AND SUITABLE FOR ACCEPTANCE OF THE
ROOFING SYSTEM. REMOVE AND REPLACE DETERIORATED WOOD NAILERS, ROOF
CURBS AND SOURED OR BADLY DETERIORATED ROOF INSULATION. JOINT OR
CRACKS GREATER THAN 1/4" SHALL BE REPAIRED.
ROOFING MEMBRANE
THE MEMBRANE MATERIAL SHALL BE IN ACCORDANCE WITH APPROVED
MANUFACTURER SPECIFICATIONS. MEMBRANE: (BASE BID) PRECISION
FABRICATED, FLEXIBLE, SINGLE-PLY,40 MIL PVC ROOFING SYSTEM. BASIS OF
DESIGN: DURO-LAST ROOFING INC. (ALTERNATE BID) SAME AS LISTED ABOVE BUT
50 MIL.
1. ALL ASHRAE ZONES: COLOR WHITE
RELATED MATERIALS:
1. DRIP EDGES, GRAVEL STOPS, COPINGS AND COUNTER FLASHINGS TO BE
COMPATIBLE AND INSTALLED ACCORDING TO ROOF MANUFACTURERS
SPECIFICATION. IF PRODUCTS USED ARE SHEET METAL, IT MUST BE A 26
GA (MIN) GALVANIZED. METAL COUNTER FLASHING, COPING, DRIP EDGES
AND GRAVEL STOPS SHALL HAVE A 3" OVERLAP FOR EXPANSION AND
CONTRACTING. CONTRACTOR TO CONSIDER UTILIZING EXCEPTIONAL
METALS PRODUCTS TO ENSURE A FULL SYSTEM WARRANTY.
2. ROOF SCUPPER LININGS: CUT ROOF SCUPPER LINING TO FIT ROOF
SCUPPERS, ALLOWING ADEQUATE MATERIAL FOR FIELD WELDING TO ROOF
COVER AND BASE FLASHING. APPLY APPROVED ADHESIVE TO SCUPPER,
INSTALL LINING IN SCUPPER AND MAKE FIELD WELDS TO ROOF COVER AND
BASE FLASHING. APPLY APPROVED SEALANT TO EXTERIOR EDGES OF
LINING ON EXTERIOR OF WALL, UNDER AND ON TOP OF THE TERMINATION
BAR SURROUNDING THE EDGES. CONTRACTOR MUST UTILIZE DURO-LAST
PREFABRICATED SCUPPER FLASHING PER DURO-LAST DETAIL 2061.
3. WOOD MEMBERS: LUMBER SHALL BE #2 SOUTHERN YELLOW PINE,
DOUGLAS FIR OR OTHER APPROVED SPECIES, AND IT SHALL BE FREE
FROM WARPING, EXCESSIVE KNOTS AND GRADE MARKED. IT SHALL BE
"WOLMANIZED" (CCA) PRESSURE-TREATED AND SHALL BEAR THE TRADE
MARK "WOLMANIZED" OR AN APPROVED EQUAL TREATMENT.
4. ROOF DRAINS AND OVERFLOW DRAINS TO BE INSTALLED ACCORDING TO
ZURN Z180 CORNICE DRAIN INSTALLATION GUIDE.
REFERENCES
A. ASTM D 958 - PRACTICE FOR DETERMINING TEMPERATURES OF STANDARD
ASTM MOLDS FOR TEST SPECIMENS OF PLASTICS.
B. AAMA 2605-05 - VOLUNTARY SPECIFICATION, PERFORMANCE REQUIREMENTS
AND TEST PROCEDURES FOR SUPERIOR PERFORMING ORGANIC COATINGS
ON ALUMINUM EXTRUSIONS AND PANELS.
C. AAMA 2604 - VOLUNTARY SPECIFICATION, PERFORMANCE REQUIREMENTS
AND TEST PROCEDURES FOR HIGH PERFORMING ORGANIC COATINGS ON
ALUMINUM EXTRUSIONS AND PANELS.
D. AAMA 2603 - VOLUNTARY SPECIFICATION, PERFORMANCE REQUIREMENTS
AND TEST PROCEDURES FOR HIGH PERFORMING ORGANIC COATINGS ON
ALUMINUM EXTRUSIONS AND PANELS.
PERFORMANCE REQUIREMENTS
A. COMPONENTS: DESIGN AND SIZE COMPONENTS TO WITHSTAND DEAD
AND LIVE LOADS CAUSED BY POSITIVE AND NEGATIVE WIND PRESSURE
ACTING NORMAL TO PLANE OF WALLS AS CALCULATED IN ACCORDANCE
WITH APPLICABLE CODE.
B. MOVEMENT: ACCOMMODATE MOVEMENT WITHIN SYSTEM WITHOUT
DAMAGE TO COMPONENTS OR MOVEMENT WITHIN SYSTEM: MOVEMENT
BETWEEN SYSTEM AND PERIMETER COMPONENTS WHEN SUBJECT TO
SEASONAL TEMPERATURE CYCLING: DYNAMIC LOADING AND RELEASE OF
LOADS: DEFLECTION OF STRUCTURAL SUPPORT FRAMING.
C. DRAINAGE: PROVIDE POSITIVE DRAINAGE TO EXTERIOR FOR MOISTURE
ENTERING OR CONDENSATION OCCURRING WITHIN PANEL SYSTEM.
SUBMITTALS
A. PRODUCT DATA: MANUFACTURER'S DATA SHEETS ON EACH PRODUCT TO
BE USED, INCLUDING:
1. PREPARATION INSTRUCTIONS AND RECOMMENDATIONS.
2. STORAGE AND HANDLING REQUIREMENTS AND RECOMMENDATIONS.
3. INSTALLATION METHODS.
B. SHOP DRAWINGS: INDICATE DIMENSIONS, LAYOUT, JOINTS, EXPANSION
JOINTS, CONSTRUCTION DETAILS, METHODS OF ANCHORAGE, AND
INTERFACE WITH ADJACENT MATERIALS.
A.
B.
C.
D.
E.
DIVISION 7 - THERMAL AND MOISTURE PROTECTION
BUILDING INSULATION
FURNISH LABOR, MATERIALS AND EQUIPMENT NECESSARY TO COMPLETE WORK
AS INDICATED ON THE CONSTRUCTION DOCUMENTS AND DESCRIBED IN THE
SPECIFICATIONS.
EXTERIOR WALL INSULATION: REFER TO INSULATION SCHEDULE ON DRAWINGS.
VAPOR BARRIER SHALL BE GRIFFOLYN T-65 BY REEF INDUSTRIES, INC. OR EQUAL.
THE MATERIAL SHALL HAVE A 3-PLY, HIGH DENSITY POLYETHYLENE AND NYLON
YARN LAMINATE. MATERIAL SHALL HAVE A REINFORCED NON-WOVEN GRID WITH A
PPT TEAR STRENGTH OF AT LEAST 15.0 LBS. VAPOR BARRIER SHALL BE APPLIED
IN THE WIDEST PRACTICAL WIDTHS. SIDE AND END JOINTS SHALL BE LAPPED AT
LEAST 6". LAPS SHALL BE SEALED USING FAB TAPE. PUNCTURES OR TEARS ARE
TO BE REPAIRED USING GRIFFOLYN'S GRIFF TAPE, FAB TAPE OR EQUAL. VAPOR
BARRIER MUST PROVIDE A COMPLETE SEAL TO PREVENT MOISTURE TRANSFER.
NOTE: FOR SOUTHERN COASTAL AREAS, THE VAPOR BARRIER SHOULD BE USED
ON THE EXTERIOR OF THE WALL. WHERE THERE IS UNCERTAINTY, FOLLOW LOCAL
PRACTICE.
RIGID ROOF INSULATION: FURNISHED AND INSTALLED BY THE ROOFING
CONTRACTOR. INSULATION TO BE MINIMUM OF (2) LAYERS OF ROOF
MANUFACTURER'S RECOMMENDED INSULATION BOARDS. INSTALL IN THICKNESS
REQUIRED TO MEET THE R-VALUES INDICATED IN THE INSULATION SCHEDULE ON
DRAWINGS. CONTRACTOR TO PROVIDE BID UTILIZING DURO-GUARD ISO II BOARDS.
'ENRGY 3' INSULATION BOARDS BY JOHNS MANVILLE ARE AN ACCEPTABLE EQUAL.
PERIMETER INSULATION: REFER TO INSULATION SCHEDULE ON DRAWINGS..
C. SELECTION SAMPLES: FOR EACH FINISH PRODUCT SPECIFIED, TWO
COMPLETE SETS OF COLOR CHIPS REPRESENTING THE
MANUFACTURER'S FULL RANGE OF AVAILABLE COLORS AND PATTERNS.
D. VERIFICATION SAMPLES: FOR EACH FINISH PRODUCT SPECIFIED, TWO
SAMPLES, MINIMUM SIZE 2 INCHES (51MM) BY 3-1/2 INCHES (89MM),
REPRESENTING ACTUAL PRODUCT, COLOR AND GLOSS.
E. MANUFACTURER'S CERTIFICATES: CERTIFY PRODUCTS MEET OR EXCEED
SPECIFIED REQUIREMENTS.
F. CLOSEOUT SUBMITTALS: PROVIDE MANUFACTURER'S MAINTENANCE
INSTRUCTIONS THAT INCLUDE RECOMMENDATIONS FOR PERIODIC
CLEANING AND MAINTENANCE OF COMPONENTS.
QUALITY ASSURANCE
A. MANUFACTURER'S QUALIFICATIONS: MINIMUM TEN YEARS' EXPERIENCE
PRODUCING ALUMINUM FINISHES OF THE TYPES SPECIFIED IN AAMA
2604 AND 2605 CERTIFIED.
B. INSTALLER: COMPANY SPECIALIZING IN PERFORMING WORK OF THIS
SECTION WITH MINIMUM THREE YEARS DOCUMENTED EXPERIENCE.
C. MOCK-UP: PROVIDE A MOCK-UP FOR EVALUATION OF SURFACE
PREPARATION TECHNIQUES AND APPLICATION WORKMANSHIP.
1. FINISH AREAS DESIGNED BY ARCHITECT.
2. DO NOT PROCEED WITH REMAINING WORK UNTIL WORKMANSHIP,
COLOR, AND GLOSS ARE APPROVED BY ARCHITECT.
REFINISH MOCK-UP AREA AS REQUIRED TO PRODUCE ACCEPTABLE
WORK.
BUILDING WEATHER BARRIER
PROVIDE WHEATHER BARRIER AS NOTED ON PLANS, SECTIONS, DETAILS, ETC.
A. FLUID APPLIED
1. ASTM E1677 : DUPONT TYVEK FLUID APPLIED WB
2. BUILDING-WRAP COMPOUND: TYVEK FLUID APPLIED FLASHING & JOINT COMPOUND
AND DUPONT SEALANT FOR TYVEK FLUID APPLIED SYSTEM.
B. BUILDING WRAP:
1. ASTM E1677: DOPONT TYVEK COMMERCIAL WRAP
2. BUILDING WRAP TAPE: PRESSURE SENSITIVE PLASTIC TAPE REMCOMENED BY
BUILDING WRAP MANUFACTURER FOR SEALING JOINTS ADN PENETRATIONS IN
BUILDING WRAP.
C. FLUID APPLIED AT E.I.F.S.
1. AS NOTED IN E.I.F.S. SECTION OF THESE SPECIFIICATIONS
12
/
2
2
/
2
0
1
7
1
2
:
3
7
:
5
9
P
M
SPECIFICATIONS
SP1
IT
EC
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
EDIN CORALIC, R.A., NCARB
2643 CAROUSEL DRIVE
ST. LOUIS, MO 63125
(314)578-4953
NO
T
U
S
E
D
NO
T
U
S
E
D
NO
T
U
S
E
D
A.
B.
C.
D.
E.
F.
A.
DIVISION 8 - OPENINGS
ALUMINUM ENTRANCE DOORS, STOREFRONT & CURTAINWALL
DOORS AND WINDOWS SHALL HAVE PRODUCT LABELS INDICATING U-VALUE, SHGC
AND AIR LEAKAGE RATE IN COMPLIANCE WITH LATEST ENERGY CODES. ALLOWED
AIR LEAKAGE SHALL NOT EXCEED 1.0 CFM/FT2 FOR GLAZED DOORS AND 0.3 CFM/FT2
FOR WINDOWS.
SYSTEMS: REFER TO EXTERIOR MATERIALS AND FINISHES SCHEDULE ON
DRAWINGS.
DOORS SHALL BE "350 MEDIUM STILE" DOOR, MANUFACTURED BY US ALUMINUM.
HARDWARE FOR ENTRANCE DOORS: SEE HARDWARE SCHEDULE ON DRAWINGS.
EXPOSED ALUMINUM MATERIAL SHALL BE CLEAR ANODIZED ALUMINUM. HARDWARE
SHALL MATCH.
MISCELLANEOUS TRIMS, SHAPES, SPACERS, AND ADAPTERS AS REQUIRED.
GLAZING
EXTERIOR GLASS SHALL BE 1" INSULATED (UNLESS NOTED OTHERWISE). SEE THE
FINISH SCHEDULE. GLAZING MUST MEET SAFETY CODES AS REQUIRED. GLASS
MUST HAVE 5-YEAR WARRANTY AGAINST SEAL FAILURE.
1. GLASS THICKNESSES: SELECT MIN. GLASS THICKNESSES PER ASTM E 1300,
PER FOLLOWING REQUIREMENTS:
a. SPECIFIED DESIGN WIND LOADS: DESIGN WIND LOADS APPLICABLE
TO PROJECT FROM BASIC WIND SPEED - IN MILES PER HOUR
(METERS PER SECOND) AT 33 FEET (10 M) ABOVE GRADE,
ACCORDING TO ASCE 7, "MINIMUM DESIGN LOADS FOR BUILDINGS
AND OTHER STRUCTURES": SECTION 6.4.2, "ANALYTIC PROCEDURE,"
BASED ON MEAN ROOF HEIGHTS ABOVE GRADE INDICATED ON
DRAWINGS.
b. PROBABILITY OF BREAKAGE FOR VERTICAL GLAZING: 8 LITES PER
1000 FOR LITES SET VERTICALLY OR NOT MORE THAN 15 DEGREES
OFF VERTICAL AND UNDER WIND ACTION.
1) LOAD DURATION: 60 SECONDS OR LESS.
c. MIN. GLASS THICKNESS FOR EXTERIOR LITES: NOT LESS THAN 6
MM.
d. THICKNESS OF TINTED AND HEAT-ABSORBING GLASS:
1) PROVIDE THE SAME THICKNESS FOR EACH TINT COLOR
INDICATED THROUGHOUT PROJECT.
B. PRODUCTS AND MANUFACTURERS
1. AVAILABLE PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS,
PRODUCTS THAT MAY BE INCORPORATED INTO THE WORK INCLUDE, BUT
ARE NOT LIMITED TO, THE PRODUCTS INDICATED IN SCHEDULES ON THE
DRAWINGS.
C. PRIMARY FLOAT GLASS
1. ASTM C 1036, TYPE I (TRANSPARENT GLASS, FLAT), QUALITY Q3 (GLAZING
SELECT); CLASS I (CLEAR).
D. HEAT-TREATED FLOAT GLASS
1. ASTM C 1048; TYPE I (TRANSPARENT GLASS, FLAT); QUALITY Q3 (GLAZING
SELECT); CLASS, KIND, AND CONDITION AS INDICATED.
A.
B.
A.
J. PREPARATION
1. CLEAN GLAZING CHANNELS AND OTHER FRAMING MEMBERS RECEIVING
GLASS IMMEDIATELY BEFORE GLAZING. REMOVE COATINGS NOT FIRMLY
BONDED TO SUBSTRATES.
K. GLAZING, GENERAL
1. COMPLY WITH COMBINED WRITTEN INSTRUCTIONS OF MANUFACTURERS OF
GLASS, SEALANTS, GASKETS, AND OTHER GLAZING MATERIALS, UNLESS
MORE STRINGENT REQUIREMENTS ARE INDICATED, INCLUDING THOSE IN
REFERENCED GLAZING PUBLICATIONS.
2. GLAZING CHANNEL DIMENSIONS, AS INDICATED ON DRAWINGS, PROVIDE
NECESSARY BITE ON GLASS, MINIMUM EDGE AND FACE CLEARANCES, AND
ADEQUATE SEALANT THICKNESSES, WITH REASONABLE TOLERANCES.
ADJUST AS REQUIRED BY PROJECT CONDITIONS DURING INSTALLATION.
3. PROTECT GLASS EDGES FROM DAMAGE DURING HANDLING AND
INSTALLATION. REMOVE DAMAGED GLASS FROM PROJECT SITE AND
LEGALLY DISPOSE OF OFF PROJECT SITE. DAMAGED GLASS IS GLASS WITH
EDGE DAMAGE OR OTHER IMPERFECTIONS THAT, WHEN INSTALLED, COULD
WEAKEN GLASS AND IMPAIR PERFORMANCE AND APPEARANCE.
4. APPLY PRIMERS TO JOINT SURFACES WHERE REQUIRED FOR ADHESION OF
SEALANTS, AS DETERMINED BY PRECONSTRUCTION SEALANT-SUBSTRATE
TESTING.
5. INSTALL SETTING BLOCKS IN SILL RABBETS, SIZED AND LOCATED TO
COMPLY WITH REFERENCED GLAZING PUBLICATIONS, UNLESS OTHERWISE
REQUIRED BY GLASS MANUFACTURER. SET BLOCKS IN THIN COURSE OF
COMPATIBLE SEALANT SUITABLE FOR HEEL BEAD.
6. DO NOT EXCEED EDGE PRESSURES PER GLASS MANUFACTURERS FOR
INSTALLING GLASS LITES.
a. PROVIDE SPACERS FOR GLASS LITES WHERE THE LENGTH PLUS
WIDTH IS LARGER THAN 50 INCHES: LOCATE SPACERS DIRECTLY
OPPOSITE EACH OTHER ON BOTH INSIDE AND OUTSIDE FACES OF
GLASS. INSTALL CORRECT SIZE AND SPACING TO PRESERVE
REQUIRED FACE CLEARANCES, UNLESS GASKETS AND GLAZING
TAPES ARE USED THAT HAVE DEMONSTRATED ABILITY TO MAINTAIN
REQUIRED FACE CLEARANCES AND TO COMPLY WITH SYSTEM
PERFORMANCE REQUIREMENTS.
b. PROVIDE 1/8-INCH (3-MM) MINIMUM BITE OF SPACERS ON GLASS AND
USE THICKNESS EQUAL TO SEALANT WIDTH. WITH GLAZING TAPE,
USE THICKNESS LESS THAN FINAL THICKNESS OF TAPE.
7. PROVIDE EDGE BLOCKING WHERE INDICATED OR NEEDED TO PREVENT
GLASS LITES FROM MOVING SIDEWAYS IN GLAZING CHANNEL, AS
RECOMMENDED IN WRITING BY GLASS MANUFACTURER AND ACCORDING TO
REQUIREMENTS IN REFERENCED GLAZING PUBLICATIONS.
8. SET GLASS LITES IN EACH SERIES WITH UNIFORM PATTERN, DRAW, BOW,
AND SIMILAR CHARACTERISTICS.
9. GLASS STOPS ARE EXTRUDED ALUMINUM SNAP-IN TYPE FOR INTERIOR
GLAZING OF GLASS OF PANELS 5/8" THICK (CUSTOM STOPS FOR
THICKNESSES UP TO AN 1" ARE AVAILABLE) AND HAVE A FIXED GASKET OF
HIGH QUALITY ELASTOMERIC MATERIAL PERIMETER WOOL PILE AND
ELASTOMERIC WEATHER-STRIP IS FACTORY APPLIED.
10. GLASS MUST HAVE (5) FIVE YEAR WARRANTY AGAINST SEAL FAILURE.
L. GLASS TYPES: REFER TO EXTERIOR MATERIALS AND FINISHES SCHEDULE ON
DRAWINGS.
STEEL SERVICE DOOR AND FRAME
STEEL DOOR FRAMES: SHALL BE 18 GUAGE STEEL WELDED VERTICAL EDGE,
MECHANICAL INTERLOCK NOT ACCEPTED, AS NOTED IN THE DOOR SCHEDULE
ON THE DRAWINGS AND AS MANUFACTURED BY BLACK MOUNTAIN,
DOOR, SERIES 400, OR EQUAL IF APPROVED BY ARCHITECT.
1. SEE THE FINISH SCHEDULE, EXTERIOR SCHEDULE AND THIS SHEET FOR
APPLICABLE PAINT.
C. STEEL HOLLOW METAL DOOR: SHALL BE 1 3/4" THICK, FLUSH TYPE, MINIMUM 18
GAUGE STEEL FACE DOOR WITH POLYSTYRENE CORE, INSULATION, ETC, AND
MANUFACTURED AS FRAMES ABOVE, REFER TO DRAWINGS.
1. SEE THE FINISH SCHEDULE, EXTERIOR SCHEDULE AND THIS SHEET FOR
APPLICABLE PAINT.
D. FINISH HARDWARE: DOORS SHALL BE PREPARED TO RECEIVE HEAVY-DUTY
HARDWARE. SEE HARDWARE SCHEDULE ON DRAWINGS FOR HARDWARE
SPECIFICATIONS.
PREFINISHED DOORS
LAMINATED DOORS: TO BE 1 3/4" SOLID CORE PRE-HUNG DOORS AS MANUFACTURED
BY MARLITE PRODUCTS. DOORS OF THIS TYPE TO BE FINISHED IN HIGH PRESSURE
LAMINATE FURNISHED COMPLETE WITH ADJUSTABLE ALUMINUM FRAME AND
HARDWARE.
1. SEE DOOR SCHEDULE FOR HARDWARE SPECIFICATIONS.
A.
A.
A.
B.
C.
D.
E.
PICK-UP WINDOW
A. ANODIZED ALUMINUM, CLEAR ANODIZED ALUMINUM FINISH.
B. VERIFY CONSTRUCTION IS READY TO RECEIVE PICK UP WINDOW. VERIFY ROUGH
OPENINGS ARE CORRECT SIZE AND IN CORRECT LOCATION. ORIENT PICK UP
WINDOW SO THAT THE OPENING MATCHES THE BUILDING ELEVATION.
EXAMINE ROUGHING-IN FOR EMBEDDED AND BUILT-IN ANCHORS TO VERIFY ACTUAL
LOCATIONS OF SECURITY WINDOW CONNECTIONS BEFORE SECURITY WINDOW
INSTALLATION. CONTRACTOR TO PROVIDE ANCHOR SCREWS.
INSPECT BUILT-IN AND CAST-IN ANCHOR INSTALLATIONS, BEFORE INSTALLING SECURITY
WINDOWS, TO VERIFY THAT ANCHOR INSTALLATIONS COMPLY WITH REQUIREMENTS.
REMOVE AND REPLACE ANCHORS WHERE INSPECTIONS INDICATE THAT THEY DO NOT
COMPLY WITH SPECIFIED REQUIREMENTS. REINSPECT AFTER REPAIRS OR
REPLACEMENTS ARE MADE.
FOR GLAZING MATERIALS WHOSE ORIENTATION IS CRITICAL FOR PERFORMANCE,
VERIFY INSTALLATION ORIENTATION. PROCEED WITH INSTALLATION ONLY AFTER
UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.
FURNISH FRAMES AND ANCHORS TO OTHER SECTIONS AS REQUIRED FOR
INSTALLATION IN SURROUNDING PARTITION AND CASEWORK CONSTRUCTION.
INSTALL PICK UP WINDOW IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
ALIGN PICK UP WINDOW PLUMB, LEVEL AND SQUARE.
RIGIDLY SECURE PICK UP WINDOW TO ADJACENT SUPPORTING CONSTRUCTION.
GLAZE WINDOWS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS
SEAL PERIMETER JOINTS
CONNECT ELECTRICAL COMPONENTS TO POWER SOURCE.
PROTECTION: WHERE DISSIMILAR METALS WILL CONTACT EACH OTHER, PROTECT
AGAINST GALVANIC ACTION BY PAINTING CONTACT SURFACES WITH PRIMER OR BY
APPLYING SEALANT OR TAPE RECOMMENDED IN WRITING BY MANUFACTURER FOR THIS
PURPOSE. WHERE ALUMINUM WILL CONTACT CONCRETE OR MASONRY, PROTECT
AGAINST CORROSION BY PAINTING CONTACT SURFACES WITH BITUMINOUS PAINT.
ACCESS DOOR
GALVANIZED STEEL, 16 GA., 24"X24" GREY ENAMEL PRIMED DOOR AND FRAME,
INSULATED DOOR; THE WILLIAMS BROS. MODEL EXT 1300 WITH CONTINUOUS HINGE,
GASKET AND KEYED CYLINDER LOCK WITH TEE HANDLE.
WALL LOUVER
STATIONARY WIND-DRIVEN RESISTANT LOUVER: RUSKIN (816-761-7476), MODEL
EME220DD, 6"X6", MILL FINISH ALUMINUM, OR APPROVED EQUAL. FIELD PAINTED AS
NOTED ON DRAWINGS.
DIVISION 9 - FINISHES
NOTE: IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE USE OF "CLASS A" OR
"CLASS C" MATERIAL.
FLOOR AND WALL TILE INSTALLATION
PROVIDE TILE WORK COMPLETE IN PLACE AS INDICATED ON DRAWINGS, SPECIFIED
HEREIN.
TILE WORK SHALL BE SUBJECT TO PERFORMANCE STANDARDS AS SET BY THE
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) SPECIFICATION A-137J-80 FOR
CERAMIC TILE OR CTI-69-5 FOR SPECIAL PURPOSE TILE AND THE TILE COUNCIL OF
AMERICA (TCA) CURRENT HANDBOOK FOR CERAMIC TILE INSTALLATION.
DELIVER MATERIAL TO THE JOB SITE AND STORE IN ORIGINAL UNOPENED CARTONS
WITH LABELS INTACT AND LEGIBLE.
TILE SHOULD BE STORED IN A DRY COVERED AREA.
TILE SHALL BE STANDARD GRADE IN ACCORDANCE WITH SPECIFICATIONS
PUBLISHED BY ANSI A-137J-80 FOR CERAMIC TILE OR CTI-69-5 FOR SPECIAL
PURPOSE TILE.
1. EXTERIOR DECORATIVE WALL TILE: SEE FINISH SCHEDULE.
2. INTERIOR FLOOR TILE: SEE FINISH SCHEDULE.
A.
B.
A.
B.
A.
B.
C.
A.
B.
A.
B.
A.
B.
C.
D.
F. TILE SETTING, GROUTING MATERIALS, AND WATERPROOFING MEMBRANE:
1. BASIS-OF-DESIGN: LATICRETE INTERNATIONAL, INC.
2. APPROVED EQUAL: MAPEI CORPORATION.
G. [MR-1] MODIFIED-PORTLAND CEMENT THIN SET MORTAR: ISO 13007: C2EP1 /
C2TES1PA AND ANSI A118.15.
1. PRODUCTS: LATICRETE: 254 PLATIUM THINSET OR MAPEI: ULTRA FLEX 2.
H. [MR-2] MEDIUM BED, MODIFIED-PORTLAND CEMENT THIN SET MORTAR: ISO 13007:
C2EP1 / C2TES1PA AND ANSI A118.15 AND CAPABLE OF BEING INSTALLED UP TO 1/4
INCH THICK.
1. PRODUCTS: LATICRETE: 4XLT OR MAPEI: ULTRA FLEX LFT.
I. [GR-1] POLYMER-MODIFIED HIGH PERFORMANCE CEMENT TILE GROUT: ISO 13007:
CG-2WAF AND ANSI A118.7.
1. PRODUCTS: FOR JOINTS 1/8-INCH OR WIDER (SANDED GROUT): LATICRETE:
PERMACOLOR: ULTRACOLOR PLUS.
2. COLORS: SEE INTERIOR AND EXTERIOR FINISH SCHEDULES..
J. [WM-1] INTERIOR WATERPROOFING MEMBRANE: COMPLY WITH ANSI A118.10.
ADJOINING FLOOR AND WALL AREAS AT MOP SINK LOCATIONS OR WHERE
INDICATED ON DRAWINGS, AND ELSEWHERE AS REQUIRED FOR WATERPROOFING
TILE ASSEMBLY AS SPECIFIED IN ANSI A108.13.
1. PRODUCTS: LATICRETE: HYDROBAN OR MAPEI: AQUA DEFENSE.
K. THRESHOLDS: PROVIDE THRESHOLDS TO ADJUST BETWEEN TILE AND OTHER
FLOOR FINISHES.
L. ACCEPTABILITY OF SURFACES: SURFACES TO BE TILED SHALL BE SMOOTH AND
LEVEL FOR MORTAR BED AT THE REQUIRED FINISH ELEVATION, AND A STEEL
TROWEL FINISH WITH A LIGHT BROOM TEXTURED FINISH WITHOUT MORE THAN THE
FOLLOWING MAXIMUM VARIATIONS:
1. PORTLAND CEMENT MORTAR: WALLS AND CEILINGS - 1/4" IN 8"; FLOORS - 1/8"
IN 10'-0".
2. DRY SET, LATEX AND CEMENT MORTARS: WALLS AND CEILINGS - 1/8" IN 8";
FLOORS - 1/8" IN 10'-0".
M. PREPARATION: PRIOR TO THE START OF LAYING TILE, SWEEP OR VACUUM AND
WASH SURFACES TO BE COVERED. SURFACE SHOULD BE FREE FROM COATING,
CURING COMPOUNDS, OIL, GREASE, WAX AND DUST.
N. JOB CONDITIONS: A MINIMUM TEMPERATURE OF 50 DEGREES F (10 DEGREES C)
SHOULD BE MAINTAINED DURING TILE WORK AND FOR SEVEN (7) DAYS
THEREAFTER. PROVIDE ADEQUATE LIGHTING FOR GOOD GROUTING AND CLEAN-
UP.
O. LAYOUT OF WORK: INTERIOR WALL AND FLOOR FINISH LAYOUTS AND PATTERNS
FOR KITCHEN, RESTROOMS AND DINING ROOM SHALL BE AS SHOWN ON INTERIOR
ELEVATIONS AND FLOOR TILE PLAN. REFER TO THE FINISH SCHEDULE. DETERMINE
LOCATIONS OF MOVEMENT (EXPANSION) JOINTS BEFORE STARTING TILE WORK.
LAYOUT TILE WORK SO AS TO MINIMIZE CUTS LESS THAN ONE HALF TILE IN SIZE.
LOCATE CUTS IN BOTH WALLS AND FLOORS SO AS TO BE LEAST CONSPICUOUS.
P. SETTING METHODS: SET TO TILE COUNCIL OF AMERICA SPECIFICATIONS WALLS
W242-98 AND FLOORS F113-98.
Q. GROUTING: FOLLOW MANUFACTURER'S RECOMMENDATIONS AS TO GROUTING
PROCEDURES AND PRECAUTIONS. REMOVE GROUT HAZE, OBSERVING GROUT
MANUFACTURER'S RECOMMENDATIONS AS TO THE USE OF VARIOUS CLEANERS.
FLOOR TILE GROUT TO BE 1/4" WIDE; WALL TILE GROUT TO BE 1/16" WIDE.
R. FINISHING: THOROUGHLY RINSE TILE WORK. USE NEUTRAL CLEANER WITH
ABRASIVE ADDITIVE (WALTER G. LEGGE'S "TEXSPAR" OR EQUAL) FOR FINAL
CLEANING. ACID CLEANERS ARE NOT RECOMMENDED EXCEPT AS NOTED.
1. USE MIXTURE OF 75% WATER AND 25% MAPEI KARACLEAN TO CLEAN TILE
SURFACE (EQUAL LATICRETE TILE CLEANER 1:3 DILUTION RATIO). APPLY AND
BUFF.
2. USE PHOSPHORIC ACID OR SULFAMIC ACID ONLY FOR REMOVAL OF GROUT
RESIDUE. DO NOT USE MURIATIC ACID.
GYPSUM DRYWALL
FURNISH MATERIAL AND LABOR NECESSARY TO PROVIDE FINISHED DRYWALL
SURFACES IN AREAS SCHEDULED TO RECEIVE THIS FINISH ON THE DRAWINGS.
TAPE, SPACKLE AND SAND SURFACES TO RECEIVE PAINT. REPEAT AS REQUIRED.
DRYWALL OVER FURRING AND WOOD STUDS SHALL BE 5/8" FIRECODE GYPSUM.
MATERIALS SHALL BE STANDARD PRODUCTS MANUFACTURED BY US GYPSUM,
NATIONAL GYPSUM OR GOLD BOND GYPSUM COMPANY.
SUSPENDED CEILING SYSTEM
FURNISH MATERIALS AND LABOR TO PROVIDE A COMPLETE SUSPENDED CEILING
INCLUDING CEILING TILE, HANGERS, GRID TEES, AND MOLDINGS.
ACOUSTICAL CEILING MATERIALS IN CORRIDOR AT RESTROOMS, RE: CT-2 ON FINISH
SCHEDULE.
C. CEILING IN THE KITCHEN, RE: CT-1 ON FINISH SCHEDULE
D. THE CEILING IN THE RESTROOMS SHALL BE SMOOTH, PAINTED GYPSUM DRYWALL.
1. COLOR: SEE THE FINISH SCHEDULE.
NON-TILE FIBERGLASS REINFORCED POLYESTER (FRP) PANELS
NON TILE WALL FINISH FRP (FOOD PREP AREA): SEE FINISH SCHEDULE.
TEXTURED FIBERGLASS REINFORCED POLYESTER (FRP) PANELS SANITARY WALL
SYSTEMS TO BE FRP PANEL. INSTALL 4'X9'X1/8 PANEL WITH HARMONIZING PVC
MOLDINGS, ADHESIVE AND SEALANTS IN STRICT ACCORDANCE WITH
MANUFACTURERS WRITTEN INSTALLATION INSTRUCTIONS.
NON-TILE WALL FINISH (DINING ROOM AREA): SEE FINISH SCHEDULE.
PAINTING
PROVIDE MATERIALS, LABOR, TOOLS AND EQUIPMENT REQUIRED TO COMPLETE THE
PAINTING OF BUILDING AS SPECIFIED.
WORKMANSHIP:
1. MATERIALS SHALL BE APPLIED FREE FROM RUNS, SAGS, WRINKLES,
STREAKS, SHINERS AND BRUSH MARKS.
2. MATERIALS SHALL BE APPLIED UNIFORMLY. IF REDUCTION OF THE COATINGS
VISCOSITY IS NECESSARY, IT SHALL BE DONE IN ACCORDANCE WITH THE
MANUFACTURER'S LABEL DIRECTIONS.
3. NEW PLASTER AND OTHER MASONRY SURFACES SHALL NOT BE PRIMED
UNTIL IT HAS BEEN DETERMINED THESE SUBSTRATES HAVE DRIED
SUFFICIENTLY TO SAFELY ACCEPT PAINT. A RELIABLE ELECTRONIC
MOISTURE METER SHOULD BE USED TO MAKE THIS DETERMINATION.
UNACCEPTABLE MOISTURE CONTENT SHOULD BE REPORTED TO THE
ARCHITECT OR HIS REPRESENTATIVE.
4. A MINIMUM INTERIOR TEMPERATURE OF 65 DEGREES F SHALL BE
MAINTAINED DURING THE ACTUAL APPLICATION AND DRYING OF THE PAINT,
AND UNTIL OCCUPANCY OF THE BUILDING OCCURS. ADEQUATE VENTILATION
SHALL BE MAINTAINED TO CONTROL EXCESSIVE HUMIDITY WHICH WILL
ADVERSELY AFFECT THE CURING OF COATINGS. THE GENERAL
CONTRACTOR IS SOLELY RESPONSIBLE FOR MAINTAINING SUITABLE
TEMPERATURES AND VENTILATION.
5. BEFORE PAINTING BEGINS, VERIFY WORK THAT CREATES DUST OR DEBRIS
HAS BEEN COMPLETED. THE ROOMS OR AREAS ARE TO BE LEFT IN BROOM
CLEAN CONDITION.
6. ENAMEL AND VARNISH UNDERCOATS ARE TO BE SANDED PRIOR TO THE
RECOATING. TOP AND BOTTOMS OF DOORS ARE TO BE FINISHED IN THE
SAME MANNER AS DOOR FACING.
7. NO EXTERIOR PAINTING SHALL BE UNDERTAKEN IF AIR OR SURFACE
TEMPERATURE IS BELOW 50 DEGREES F, NOR IMMEDIATELY FOLLOWING
RAIN OR UNTIL FROST, DEW OR CONDENSATION HAS EVAPORATED.
SURFACES SHOULD ALWAYS BE TESTED WITH MOISTURE METER BEFORE
PROCEEDING.
C. PREPARATION OF SURFACES:
1. DO NOT COMMENCE WORK UNTIL SURFACE IS IN PROPER CONDITION.
2. SURFACES ARE TO BE CLEAN. IF FOR ANY REASON THE SURFACE CANNOT
BE CLEANED, THIS CONDITION SHALL BE PROMPTLY REPORTED TO THE
GENERAL CONTRACTOR AND OWNER.
3. THE PRIME COAT SHOULD BE APPLIED SOON AFTER SURFACE PREPARATION
HAS BEEN COMPLETED, TO PREVENT CONTAMINATION OF THE SUBSTRATE.
D. INSPECTION: WORK NOT CONFORMING TO THE SPECIFICATIONS OR NOT MEETING
WITH THE APPROVAL OF THE OWNER, SHALL BE REMOVED OR CORRECTED AND/OR
REPAINTED AS APPROVED BY THE OWNER.
PAINT SCHEDULE
EXTERIOR ITEMS: REFER TO EXTERIOR FINISH SCHEDULE.
INTERIOR WOOD TRIM: REFER TO FINISH SCHEDULE
PATIO CONCRETE SLAB
CONCRETE SLAB TO BE A MINIMUM OF 5" THICK - VERIFY SLAB REQUIREMENTS WITH
GEOTECHNICAL REPORT.
BROOM FINISHED CONCRETE WITH TROWELED EDGES.
CONCRETE SEALER: 'SCOFIELD' CEMENTONE CLEAR SEALER. APPLY PER
MANUFACTURER'S RECOMMENDATIONS.
CONCRETE COLOR HARDENER: 'SCOFIELD' LITHOCHROME, A33 "CLASSIC GREY"
APPLY PER MANUFACTURER'S RECOMMENDATIONS.
EXECUTION
EXAMINATION
A. DO NOT BEGIN INSTALLATION UNTIL COLORS HAVE BEEN VERIFIED.
B. VERIFY FRAMING MEMBERS ARE READY TO RECEIVE PANEL SYSTEM.
C. IF PREPARATION IS THE RESPONSIBILITY OF ANOTHER INSTALLER, NOTIFY
ARCHITECT OF UNSATISFACTORY PREPARATION BEFORE PROCEEDING.
PREPARATION
A. CLEAN SURFACES THOROUGHLY PRIOR TO INSTALLATION.
B. PREPARE SURFACES USING METHODS RECOMMENDED BY THE
MANUFACTURER.
INSTALLATION
A. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION
INSTRUCTIONS.
B. BARRIER PROTECTION: DO NOT INSTALL OVER CEMENTITIOUS MATERIALS,
DISSIMILAR METALS OR PRESSURE TREATED MATERIAL WITHOUT
ADEQUATE BARRIER PROTECTION.
1. INSTALL BUILDING PAPER HORIZONTALLY ON WALLS TO RECEIVE
METAL SIDING.
2. WEATHER LAP EDGES 6 INCHES (150MM) AND ENDS MINIMUM 6 INCHES
(150MM).
3. STAGGER VERTICAL JOINTS F EACH LAYER.
4. SECURELY STAPLE, NAIL IN PLACE.
C. FASTEN SIDING TO STRUCTURAL SUPPORTS; ALIGNED, LEVEL, AND
PLUMB.
D. LOCATE JOINTS OVER SUPPORTS.
E. INSTALL EXPANSION CONTROL JOINTS WHERE NEEDED.
F. USE CONCEALED FASTENERS UNLESS OTHERWISE APPROVED BY
ARCHITECT.
G. INSTALL SOFFITS, AND ACCESSORIES IN ACCORDANCE WITH BEST
PRACTICE, WITH ALL JOINT MEMBERS PLUMB AND TRUE.
FIELD QUALITY CONTROL
A. AFTER INSTALLATION OF SOFFITS, CHECK ENTIRE SURFACE FOR
OBVIOUS FLAWS OR DEFECTS.
B. REPLACE AND REPAIR ANY PROBLEM AREAS, PAYING CLOSE ATTENTION
TO THE SUBSTRATE FOR CAUSES OF THE PROBLEM.
CLEANING
A. UPON COMPLETION OF SOFFIT APPLICATION, CLEAN ENTIRE AREA,
REMOVING ALL SCRAP METAL, PACKAGING AND UNUSED MATERIALS
RELATED TO THE INSTALLATION. CLEAN PANELS AS NECESSARY TO
REMOVE ALL FINGERPRINTS AND SOILED AREAS.
PROTECTION
A. PROTECT INSTALLED PRODUCTS UNTIL COMPLETION OF PROJECT
TOUCH-UP, REPAIR OR REPLACE DAMAGED PRODUCTS BEFORE
SUBSTANTIAL COMPLETION.
E. INSULATING GLASS
1. PREASSEMBLED UNITS CONSISTING OF SEALED LITES OF GLASS
SEPARATED BY A DEHYDRATED INTERSPACE, AND COMPLYING WITH ASTM E
774 FOR CLASS CBA UNITS AND WITH REQUIREMENTS SPECIFIED IN THIS
ARTICLE.
a. PROVIDE KIND HS (HEAT-STRENGTHENED) FLOAT GLASS IN PLACE OF
ANNEALED GLASS WHERE NEEDED TO RESIST THERMAL STRESSES
INDUCED BY DIFFERENTIAL SHADING OF INDIVIDUAL GLASS LITES
AND TO COMPLY WITH GLASS DESIGN REQUIREMENTS SPECIFIED IN
"PERFORMANCE REQUIREMENTS" ARTICLE. PROVIDE KIND FT (FULLY
TEMPERED) WHERE SAFETY GLASS IS INDICATED.
2. OVERALL UNIT THICKNESS AND THICKNESS OF EACH LITE: DIMENSIONS
INDICATED IN THE GLASS SCHEDULE ARE NOMINAL AND THE OVERALL
THICKNESSES OF UNITS MEASURED PERPENDICULARLY FROM OUTER
SURFACES OF GLASS LITES AT UNIT'S EDGE.
3. SEALING SYSTEM: DUAL SEAL, WITH PRIMARY AND SECONDARY SEALANTS
AS FOLLOWS:
a. RETAIN ONE SEALANT SYSTEM BELOW OR REVISE TO INSERT OTHER
COMBINATIONS; CORRELATE WITH PRODUCTS/MANUFACTURERS
SELECTED.
1) MANUFACTURER'S STANDARD SEALANTS.
4. SPACER SPECIFICATIONS: MANUFACTURER'S STANDARD SPACER MATERIAL
AND CONSTRUCTION COMPLYING WITH THE FOLLOWING REQUIREMENTS:
a. ALUMINUM WITH CLEAR ANODIZED ALUMINUM FINISH.
b. DESICCANT: MOLECULAR SIEVE OR SILICA GEL, OR BLEND OF BOTH.
c. CORNER CONSTRUCTION: MANUFACTURER'S STANDARD CORNER
CONSTRUCTION.
5. LOW E - SPUTTER-COATED FLOAT GLASS; ASTM C1376 APPLIED TO SURFACE
#2.
F. SPANDREL GLASS: REFER TO EXTERIOR MATERIALS AND FINISHES SCHEDULE ON
DRAWINGS.
G. MISCELLANEOUS GLAZING MATERIALS
1. GENERAL: PROVIDE PRODUCTS OF MATERIAL, SIZE, AND SHAPE COMPLYING
WITH REFERENCED GLAZING STANDARD, REQUIREMENTS OF
MANUFACTURERS OF GLASS AND OTHER GLAZING MATERIALS FOR
APPLICATION INDICATED, AND WITH A PROVEN RECORD OF COMPATIBILITY
WITH SURFACES CONTACTED IN INSTALLATION.
2. CLEANERS, PRIMERS, AND SEALERS: TYPES RECOMMENDED BY SEALANT
OR GASKET MANUFACTURER.
3. SETTING BLOCKS: ELASTOMERIC MATERIAL WITH A SHORE TYPE A
DUROMETER HARDNESS OF 85, +/- 5.
4. SPACERS: ELASTOMERIC BLOCKS OR CONTINUOUS EXTRUSIONS WITH A
SHORE TYPE A DUROMETER HARDNESS REQUIRED BY GLASS
MANUFACTURER TO MAINTAIN GLASS LITES IN PLACE FOR INSTALLATION
INDICATED.
5. EDGE BLOCKS: ELASTOMERIC MATERIAL OF HARDNESS NEEDED TO LIMIT
GLASS LATERAL MOVEMENT (SIDE WALKING).
H. FABRICATION OF GLASS AND OTHER GLAZING PRODUCTS
1. FABRICATE GLASS AND OTHER GLAZING PRODUCTS IN SIZES REQUIRED TO
GLAZE OPENINGS INDICATED FOR PROJECT, WITH EDGE AND FACE
CLEARANCES, EDGE AND SURFACE CONDITIONS, AND BITE COMPLYING WITH
WRITTEN INSTRUCTIONS OF PRODUCT MANUFACTURER AND REFERENCED
GLAZING STANDARD, TO COMPLY WITH SYSTEM PERFORMANCE
REQUIREMENTS.
2. GRIND SMOOTH AND POLISH EXPOSED GLASS EDGES.
I. EXAMINATION
1. EXAMINE FRAMING GLAZING, WITH INSTALLER PRESENT, FOR COMPLIANCE
WITH THE FOLLOWING:
a. MANUFACTURING AND INSTALLATION TOLERANCES, INCLUDING
THOSE FOR SIZE, SQUARENESS, AND OFFSETS AT CORNERS.
b. PRESENCE AND FUNCTIONING OF WEEP SYSTEM.
c. MINIMUM REQUIRED FACE OR EDGE CLEARANCES.
d. EFFECTIVE SEALING BETWEEN JOINTS OF GLASS-FRAMING
MEMBERS.
2. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS
HAVE BEEN CORRECTED.
KNOTWOOD (CONTINUED)
“
NO
T
U
S
E
D
12
/
2
2
/
2
0
1
7
1
2
:
3
8
:
0
9
P
M
SPECIFICATIONS
SP2
IT
EC
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
EDIN CORALIC, R.A., NCARB
2643 CAROUSEL DRIVE
ST. LOUIS, MO 63125
(314)578-4953
A.
A.
A.
B.
A.
B.
A.
A.
A.
B.
C.
A.
DIVISION 10 - SPECIALTIES
GENERAL SIGNAGE
A. FOR BUILDING, FREE-STANDING PYLON, AND GROUND AND DIRECTIONAL SIGNS:
1. NEW STORES: WHITE WENDY'S LETTERS ON RED BACKGROUND, POLES AND
HARDWARE PAINTED PPG "BRILLIANT RED."
2. REMODEL STORES: NEW SIGN FACE, BODY REPAINTED PPG "BRILLIANT
RED."
B. SIGNAGE INCLUDING MENU AND SPEAKER SIGNS SHALL BE FURNISHED BY OWNER
AND INSTALLED BY LICENSED SIGN ERECTOR. SEE APPROVED SIGN
MANUFACTURERS LIST.
C. BUILDING SIGNS:
1. COORDINATE BUILDING IDENTITY SIGNS WITH OWNERS REPRESENTATIVE.
2. SIGNS TO BE PROVIDED AND INSTALLED BY MANUFACTURER FROM
APPROVED SIGN MANUFACTURERS LIST.
D. MENU BOARDS (INTERIOR AND EXTERIOR): SEE LISTING OF APPROVED SIGN
MANUFACTURERS.
1. BUILDINGS REQUIRE:
a. ONE EXTERIOR BRONZE MENU BOARD WITH ORDER CONFIRMATION
SYSTEM WITHIN SPEAKER PEDESTAL.
ROOM IDENTIFICATION SIGN
A. SIGN IS DESIGNED WITH CONTRASTING COLORS, RAISED LETTERS, AND GRADE II
BRAILLE CONFORMING WITH THE AMERICANS WITH DISABILITIES ACT STANDARDS
FOR ACCESSIBLE DESIGN.
RESTROOM IDENTIFICATION SIGN
SIGN IS DESIGNED WITH CONTRASTING COLORS, RAISED LETTERS, AND GRADE II
BRAILLE CONFORMING WITH THE AMERICANS WITH DISABILITIES ACT STANDARDS
FOR ACCESSIBLE DESIGN. FURNISHED BY OWNER AND INSTALLED BY
CONTRACTOR. SIGN IS MOUNTED ON WALL (LATCH SIDE OF DOOR) PER THE
DRAWINGS.
PUBLIC RESTROOM ACCESSORIES
TOILET ROOM ACCESSORIES TO BE PROVIDED AND INSTALLED BY THE GENERAL
CONTRACTOR. SEE PROJECT DRAWINGS FOR ACCESSORY SPECIFICATION AND
LOCATIONS.
WALL DECOR
A. ARTWORK TO BE MOUNTED TO WALLS WITH CONCEALED SECURITY HARDWARE
SUPPLIED WITH DECOR. REFER TO "MISCELLANEOUS-FINISH SCHEDULE"
MISCELLANEOUS ITEMS: FURNISHINGS: VERIFY ALL MATERIALS AND FINISHES WITH
THE FINISH SCHEDULE AND OWNER'S REPRESENTATIVE.
HEIGHT WARNING DEVICE
HEIGHT WARNING DEVICES, IF USED ARE TO BE STEEL PIPE CONSTRUCTION WITH A
SELF RETURNING 6' MIN. LENGTH HORIZONTAL WARNING BAR MOUNTED AT A
HEIGHT AT OR BELOW THE HEIGHT OF ANY AWNINGS THEY ARE MEANT TO
PROTECT. WARNING DEVICE SHALL BE EQUIPPED WITH A SIGN INDICATING THE
SAFE VEHICLE HEIGHT.
WARNING DEVICES SHOULD BE INSTALLED WHEREVER DRIVE-THRU
AWNINGS ARE INSTALLED AND THERE IS NO OTHER MEANS OF WARNING THAT THE
VEHICLE IS IN DANGER OF CONTACTING THOSE AWNINGS. VERIFY EXACT LOCATION
OF WARNING DEVICES WITH OWNER PRIOR TO INSTALLATION.
FOR APPROVED WARNING DEVICE MANUFACTURERS: SEE APPROVED SUPPLIERS
LIST.
ORDER STATION CANOPY
THE CANOPY SUPPLIER IS RESPONSIBLE FOR THE DESIGN, CONSTRUCTION AND
MOUNTING DETAILS NECESSARY TO PROVIDE A SAFE AND STRUCTURALLY SOUND
INSTALLATION FOR THE GEOGRAPHICAL LOCATION IN WHICH THE CANOPY IS
INSTALLED. WIND LOADS SHOULD BE PER THE LOCAL BUILDING CODES. IF
REQUESTED BY THE LOCAL BUILDING AUTHORITY, THE CANOPY SUPPLIER SHALL
SHOW COMPLIANCE WITH THE BUILDING CODE BY SUPPLYING DETAILED DRAWINGS
SIGNED AND SEALED BY AN ENGINEER REGISTERED IN THE STATE IN WHICH THE
CANOPY IS BEING INSTALLED.
THE CANOPY SUPPLIER WILL PROVIDE THERMOSTATICALLY CONTROLLED HEAT
TRACE SNOW MELTING UNITS ON THE ORDER STATION CANOPY IN ASHRAE ZONES
4 AND HIGHER. SNOW HEAT TRACE UNITS ARE OPTIONAL IN ZONE 3. THE
ARCHITECT OF RECORD AND ENGINEER OF RECORD ARE RESPONSIBLE FOR
DETERMINING IF THE HEAT TRACE IS WARRANTED.
KITCHEN EQUIPMENT
KITCHEN EQUIPMENT SERVICEMAN WILL SET UP EQUIPMENT WITH GENERAL
CONTRACTOR MAKING FINAL HOOK-UPS. (THIS WILL ALSO INCLUDE PURCHASED
KITCHEN EQUIPMENT ITEMS).
HOOD FIRE SUPPRESSION SYSTEM AND PORTABLE FIRE EXTINGUISHERS
HOOD FIRE SUPPRESSION SYSTEM SHALL BE AS PER SPECIFICATIONS AND
DRAWINGS MANUFACTURED BY PYRO-CHEM OR ANSUL (NO SUBSTITUTES).
SYSTEM SHALL BE FURNISHED AND INSTALLED BY HOOD MANUFACTURER UNLESS
OTHERWISE INSTRUCTED BY OWNER (VERIFY WITH OWNER BEFORE
CONSTRUCTION). PORTABLE EXTINGUISHERS SHALL BE FURNISHED BY GC
AND SHALL BE INSTALLED AS DIRECTED BY LOCAL FIRE CONTROL
AUTHORITY.
FIRE EXTINGUISHER CABINETS
FIRE EXTINGUISHER CABINET: CONSULT BUILDING MATERIAL CONSOLIDATOR
REFER TO DRAWINGS FOR INSTALLATION LOCATION.
BLOCKING: G.C. SHALL PROVIDE IN-WALL WOOD BLOCKING AS REQUIRED FOR
INSTALLATION OF CABINET
FINISH SPECIFICATIONS:
1. DOOR STYLE: FULL GLAZING (STYLE F)
2. DOOR GLAZING: CLEAR TEMPERED GLASS.
3. CABINET FINISH: STANDARD CLEAR ANODIZED ALUMINUM
WALK-IN FREEZER/COOLER/DRY STORAGE (PRE-FABRICATED)
A. PLACEMENT OF PRE-FABRICATED, WALK-IN FREEZER/COOLER/DRY STORAGE SHALL
BE PART OF THIS CONTRACT. UNIT WILL BE SUPPLIED BY OWNER AND WILL BE
SHIPPED DIRECT TO STORE LOCATION WITH ALL UNCRATING AND ERECTION
COORDINATED BY GENERAL CONTRACTOR AND WALK-IN MANUFACTURER. UNIT
WILL BE SHIPPED COMPLETE WITH HARDWARE AND INSTRUCTIONS.
B. FLOOR IN FREEZER IS PREFABRICATED. FLOORING IN COOLER AND DRY STORAGE
IS CERAMIC TILE WITH STAINLESS STEEL COVE BASE BY GENERAL CONTRACTOR.
INSTALLATION OF REFRIGERATION TO BE COORDINATED BY GENERAL CONTRACTOR
AND WALK-IN MANUFACTURER.
C. GENERAL CONTRACTOR SCOPE OF WORK. REFER TO DRAWINGS
1. ELECTRICAL CONNECTION OF WALK IN BOX LIGHTS AND CONDENSERS.
2. INSTALL CONDENSATE DRAIN LINE FROM WALK IN BOX TO DESIGNATED FLOOR
SINK.
3. SECURITY SYSTEM CONDUITS FOR SECURITY ALARM IN COOLER / FREEZER.
4. SUPPLY AND INSTALL COUNTER FLASHING FOR WALK IN BOX / BUILDING
INTERFACE
WALK-IN FREEZER/COOLER/DRY STORAGE (FIELD ERECTED)
A. INSTALLATION OF FIELD ERECTED WALK-IN FREEZER/COOLER/DRY STORAGE IS NOT
PART OF THIS CONTRACT. UNIT WILL BE SUPPLIED BY OWNER. WALK IN BOX
SUPPLIER INSTALLS PANELS, REFRIGERATION SYSTEM, AND MEMBRANE ROOF.
B. FLOOR IN FREEZER IS INSTALLED BY WALK IN BOX SUPPLIER. FLOORING IN COOLER
AND DRY STORAGE IS CERAMIC TILE BY GENERAL CONTRACTOR. I SEE EQUIPMENT
PLAN OF THE CONSTRUCTION DOCUMENTS.
C. GENERAL CONTRACTOR SCOPE OF WORK. REFER TO DRAWINGS.
1. PROVIDE AND INSTALL CONDUITS AND WIRING FOR LIGHTS
2. CONNECT ELECTRICAL FOR REFRIGERATION SYSTEM
3. INSTALL CONDUITS FOR SECURITY ALARM IN COOLER / FREEZER
4. INSTALL CONDENSATE DRAIN LINE SYSTEM INSIDE WALK IN BOX TO DESIGNATED
FLOOR SINK.
5. SUPPLY AND INSTALL COUNTER FLASHING FOR WALK IN BOX / BUILDING
INTERFACE
COMMUNICATION SYSTEM
TOTAL COMMUNICATION SYSTEM AS INDICATED ON DRAWINGS. SYSTEM SHALL BE
AS MANUFACTURED BY H.M.E. SYSTEM SHALL BE FURNISHED AND INSTALLED BY
OWNER. CONTRACTOR TO FURNISH CONDUIT, ELECTRICAL CONNECTION AND CO-
ORDINATE INSTALLATION.
C. APPROVED CANOPY MANUFACTURES: SEE APPROVED SUPPLIERS LISTS.
12
/
2
2
/
2
0
1
7
1
2
:
3
8
:
1
5
P
M
SPECIFICATIONS
SP3
IT
EC
MO
O
D
Y
R
D
&
N
2
N
D
E
RE
X
B
U
R
G
,
I
D
8
3
4
4
0
PROJECT TYPE:
SITE NUMBER:
BUILDING TYPE:
OWNER:
BASE VERSION:
DRAWING RELEASE:
PROJECT YEAR:
ASSET TYPE:
CLASSIFICATION:
UPGRADE CLASSIFICATION:
DESIGN TYPE:
#13487
(2.0) SMART 40+
FREESTANDING
NEW
FRANCHISE
2020
NEW BUILD
2021
(2.0) UM BRITE
SUMMER
NEW
SMART 40+
EDIN CORALIC, R.A., NCARB
2643 CAROUSEL DRIVE
ST. LOUIS, MO 63125
(314)578-4953