Loading...
HomeMy WebLinkAboutPLANS - 21-00546 - Costa Vida - Drive-Thru AdditionJR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com DMEKBBIF21-094 PRO F E S S I O N A L ENG I N E E R S T ATE O F I D A H O A 6/ 2 / 2 1 14 1 3 4 D VID B . P O R T E R L I C E N SED STRUCTURAL ENGINEERING GENERAL STRUCTURAL NOTES (APPLY UNLESS NOTED OTHERWISE ON PLANS/DETAILS) GENERAL REQUIREMENTS: 1.THE STRUCTURAL SYSTEMS AND MEMBERS DEPICTED HEREIN HAVE BEEN DESIGNED PRIMARILY TO SAFEGUARD AGAINST MAJOR STRUCTURAL DAMAGE AND LOSS OF LIFE, NOT TO LIMIT DAMAGE OR MAINTAIN FUNCTION (IBC SECTION 101.3). 2.THESE DRAWINGS, AND THEIR ASSOCIATED STRUCTURAL CALCULATIONS, HAVE BEEN PERFORMED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEER'S IN THIS OR SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE INTERNATIONAL BUILDING CODE CONVENTIONAL FRAMING REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR FRAMING ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3.THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION SUCH THAT DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, AND SHALL COORDINATE ALL DETAILS. 4.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. TYPICAL DETAILS AND NOTES ARE NOT NECESSARILY INDICATED ON THE PLANS, BUT SHALL APPLY NONE-THE-LESS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. 5.ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT AND STRUCTURAL ENGINEER. 6.ANY INSPECTIONS, SPECIAL (IBC CHAPTER 17) OR OTHERWISE THAT ARE REQUIRED BY THE BUILDING CODES, LOCAL BUILDING DEPARTMENTS, OR BY THESE PLANS SHALL BE DONE BY AN INDEPENDENT INSPECTION COMPANY OR THE BUILDING DEPARTMENT, SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR. 7.SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS IN ADDITION TO ITEMS REQUIRED BY ARCHITECTURAL SPECIFICATIONS, THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DRAWINGS SHALL BE FLAGGED UPON HIS REVIEW. VERIFY ALL DIMENSIONS WITH ARCHITECT. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM ORIGINAL CONTRACT DRAWINGS SHALL BE CLOUDED. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED APPROVED AFTER THE STRUCTURAL ENGINEER'S REVIEW, UNLESS NOTED ACCORDINGLY. ANY ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A STRUCTURAL ENGINEER REGISTERED IN THE APPROPRIATE STATE. THE SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL CONTRACT DRAWINGS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER ARE NOT TO BE CONSIDERED CHANGES TO ORIGINAL DRAWINGS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY THE OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ALLOW (5) WORKING DAYS FOR THE STRUCTURAL ENGINEER'S REVIEW. ONE COPY OF EACH SUBMITTAL WILL BE RETAINED FOR THE STRUCTURAL ENGINEER'S RECORDS. BASIS FOR DESIGN: 1.BUILDING CODE: 2018 EDITION OF THE IBC WITH CITY/COUNTY AMENDMENTS. RISK CATEGORY = II 4. SEISMIC DESIGN PARAMETERS: ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE IMPORTANCE FACTOR Ie = 1.00 SITE CLASS D SEISMIC DESIGN CATEGORY D MAPPED SPECTRAL RESPONSE ACCELERATIONS S1 = 0.143, SS = 0.369 DESIGN SPECTRAL RESPONSE ACCELERATIONS SD1 = 0.221, SDS = 0.370 PERCENT SNOW INCLUDED WITH SEISMIC LOADS 20 VERTICAL SHEAR TRANSFER ELEMENTS: SPECIAL MASONRY SHEARWALL(S)R = 5, CS = 0.074 5. WIND DESIGN PARAMETERS (STRENGTH): ULTIMATE WIND SPEED 115 MPH (3 SECOND GUST) WIND EXPOSURE C IMPORTANCE FACTOR Iw = 1.00 INTERNAL PRESSURE COEFFICIENT -0.18 COMPONENT AND CLADDING PRESSURE 28.3 PSF NET UPLIFT ON ROOF 21.8 PSF (ASD) 2. VERTICAL LOADS: LOCATION LIVE / SNOW LOAD DEAD LOAD ROOF 35 PSF 20 PSF 3. DEFLECTION LIMITS: ELEMENTS LIVE LOAD TOTAL LOAD ROOF JOISTS L/360 L/240 BEAMS L/360 L/240 FOUNDATION NOTES: 1.IN LIEU OF A GEOTECHNICAL REPORT: THE FOUNDATION HAS BEEN DESIGNED ACCORDING TO THE RECOMMENDATIONS OF CHAPTER 18 OF THE IBC. 2.THE SOIL DESIGN VALUES LISTED BELOW HAVE BEEN APPROVED BY THE CITY/COUNTY BUILDING DEPARTMENT, CONTINGENT THAT THE SOIL ON THE SITE PREDOMINATELY CONSISTS OF SAND AND/OR GRAVEL. SPECIFIC SOIL CLASSIFICATIONS SHOULD BE ONE OF THE FOLLOWING: SANDY GRAVEL OR GRAVEL(GW OR GP), SAND(SW AND SP), SILTY SAND(SM), CLAYEY SAND(SC), SILTY GRAVEL(GM), OR CLAYEY GRAVEL(GC). THESE SOIL CLASSIFICATIONS CAN BE FOUND IN TABLE 1806.2 OF CHAPTER 18 OF THE IBC. VERIFICATION OF SOIL CLASSIFICATION IS THE RESPONSIBILITY OF THE CONTRACTOR. 3.A ONE-THIRD INCREASE IN BEARING PRESSURES IS ALLOWED WITH SEISMIC OR WIND LOAD COMBINATIONS. LATERAL BEARING AND LATERAL SLIDING RESISTANCE MAY BE COMBINED. 4.ALL FOUNDATIONS SHALL BEAR ON COMPACTED ENGINEERED FILL OR COMPETENT NATIVE SOIL SUBBASE COMPACTED TO 95% DRY DENSITY (STANDARD PROCTOR). GRADE IS DEFINED AS LOWEST ADJACENT GRADE WITHIN 5 FEET OF THE BUILDING FOR PERIMETER FOOTINGS. WHERE EXTERIOR PAVING OR CONCRETE IS DIRECTLY ADJACENT TO BUILDING, GRADE IS DEFINED AS TOP OF EXTERIOR PAVING AT LEAST 5 FEET FROM BUILDING. CONCRETE FOOTING EXCAVATIONS SHALL BE CLEAN AND FREE OF LOOSE DEBRIS OR UN-COMPACTED MATERIAL AT TIME OF CONCRETE PLACEMENT. 5.CONCRETE SLABS ON GRADE SHALL BE SUPPORTED ON A 4 INCH (MIN) LAYER OF FREE-DRAINING GRANULAR MAT (DRAINAGE FILL COURSE). THE MAT SHOULD CONSIST OF A WELL GRADED SAND AND GRAVEL MIXTURE WITH MAXIMUM 3/4-INCH CRUSHED AGGREGATE. THE GRANULAR MAT SHOULD BE COMPACTED TO NO LESS THAN 95% OF THE MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557. 6.BACKFILL AGAINST RESTRAINED WALLS SHALL NOT BE PLACED UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION OF INTERIOR FLOOR SYSTEMS AND CONCRETE OR GROUT STRENGTH HAS REACHED THE 28 DAY STRENGTH LISTED BELOW. THE SOIL DESIGN VALUES FOR THE FOUNDATION ARE: ALLOWABLE BEARING PRESSURE 1500 PSF ALLOWABLE LATERAL BEARING PRESSURE 150 PSF/FT ALLOWABLE LATERAL SLIDING COEFFICIENT 0.25 FOUNDATION BEARING DEPTH 36" BELOW FINISHED GRADE CONCRETE: 2.ALL NORMAL WEIGHT CONCRETE SHALL BE REGULAR WEIGHT OF 150 POUNDS PER CUBIC FOOT USING HARD-ROCK AGGREGATES. AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. 3.LAP SPLICES FOR BEAMS AND FLOOR SLABS SLABS SHALL BE ACCORDING TO CHAPTER 12 OF ACI 318 OR LAP SCHEDULE ON THESE DRAWINGS. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. LATEST ACI CODE AND DETAILING MANUAL APPLY. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO CENTER OF STEEL. MINIMUM COVER FOR NON-PRESTRESSED CONCRETE REINFORCING SHALL BE AS FOLLOWS: 5.MAXIMUM SLUMP FOR ALL CONCRETE SHALL BE 6". PORTLAND CEMENT SHALL CONFORM TO ASTM C150. TYPE V CEMENT SHALL BE USED FOR CONCRETE IN CONTACT WITH ALKALINE SOIL, AND TYPE II ELSEWHERE. 6.NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY THE TESTING AGENCY. 7.CONCRETE PLACEMENT AND QUALITY SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301 AND ACI 318. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AROUND AND UNDER FLOOR DUCTS, ETC. CAST CLOSURE POUR, WHERE SHOWN ON PLANS AROUND COLUMNS AFTER COLUMN DEAD LOAD IS APPLIED. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING CONCRETE. ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING, DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY POSITIONED IN THE FORMS BEFORE PLACING THE CONCRETE. 8.ALL CONCRETE SLABS ON GRADE SHALL BE DIVIDED INTO AREAS BY CONTROL JOINTS (KEYED OR SAW CUT) SUCH THAT ONE SLAB AREA DOES NOT EXCEED A MAXIMUM LENGTH OF 24 TIMES THE SLAB THICKNESS IN BOTH DIRECTIONS (EXAMPLE: 4" SLAB = 8'-0" LENGTH). SQUARE LAYOUTS ARE PREFERRED, BUT THE SLAB GEOMETRY MAY DICTATE OTHERWISE. THE RATIO OF THE LONG TO SHORT DISTANCE SHALL NOT EXCEED 1.3. IT IS RECOMMENDED THAT SAW CUTS BE MADE WITHIN 16 HOURS OF CONCRETE BATCHING. KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. 9.HORIZONTAL PIPES AND ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE AND SLABS ON GRADE EXCEPT WHERE SPECIFICALLY APPROVED OR NOTED BY THE STRUCTURAL ENGINEER. PIPES AND CONDUITS SHALL NOT IMPAIR THE STRENGTH OF THE WORK. 10.FLY ASH MAY BE USED ONLY IF PERMITTED BY ARCHITECTURAL SPECIFICATIONS AND SHALL BE LIMITED TO 18 PERCENT OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE. 11.COLD/HOT WEATHER CONCRETE CONSTRUCTION: PROTECT CONCRETE FROM DAMAGE OR REDUCED STRENGTH IN COMPLIANCE WITH ACI 305 AND 306. 12.CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. 13.LIMIT ALKALI-SILICA REACTION (ASR) TO 0.1% EXPANSION AT 28 DAYS IN CONCRETE MIX AT ALL EXTERIOR CONCRETE AND INTERIOR CONCRETE EXPOSED TO MOISTURE. LOCATION:MINIMUM COVER TOLERANCE CAST AGAINST EARTH (FOOTINGS)3"± 3 8" SLABS ON GRADE 112"± 14" EXPOSED TO EARTH OR WEATHER - #5 AND SMALLER 112"± 3 8" EXPOSED TO EARTH OR WEATHER - #6 AND LARGER 2"± 3 8" NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND ROOF SLAB 1"18" STRUCTURAL SLABS AND WALLS 3 4"18" BEAMS AND COLUMNS (PRIMARY) REINFORCEMENT, TIES, STIRRUPS AND SPIRALS 112"3 8" 1. MINIMUM 28 DAY CONCRETE STRENGTH SHALL BE AS FOLLOWS: USE:CONCRETE STRENGTH: MAX W/C RATIO AIR ENTRAINMENT FOOTINGS 3500 PSI 0.50 5.5% ± 1% FOUNDATION WALLS 4500 PSI 0.45 5.5% ± 1% INTERIOR CONCRETE SLABS ON GRADE 3500 PSI 0.45 N/A REINFORCING STEEL: 1.ASTM A615 GRADE 60 (FY = 60 KSI) DEFORMED BARS FOR ALL BARS #4 AND LARGER. ASTM A615 GRADE 40 (FY = 40 KSI) DEFORMED BARS FOR ALL BARS #3 AND SMALLER. GRADE 60 DEFORMED BARS SHALL BE USED FOR CONCRETE WALLS, BEAMS, ELEVATED SLABS AND COLUMN REINFORCING. 2.WELDING OF REINFORCING BARS SHALL BE MADE ONLY TO ASTM A706 GRADE 60 BARS AND ONLY USING E90 SERIES RODS. WELDING OF REINFORCING BARS SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. 3.REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. DEFERRED SUBMITTAL ITEMS: PREFABRICATED STEEL ROOF JOISTS MASONRY (CONCRETE BLOCK): MINIMUM 28 DAY MASONRY STRENGTH SHALL BE 2000 PSI. MASONRY COMPRESSIVE STRENGTH: NET COMPRESSIVE STRENGTH OF THE OVERALL MASONRY SYSTEM (MORTAR, UNITS, AND GROUT) SHALL BE f'M=2,000 PSI (BY UNIT STRENGTH METHOD) 1.VERTICAL REINFORCING: #5 AT 16 INCHES ON CENTER FULL HEIGHT OF WALL, CENTERED IN GROUTED CELL AND AT ALL WALL INTERSECTIONS, CORNERS, WALL ENDS, JAMBS, OVER LINTELS, AND EACH SIDE OF CONTROL JOINTS (MINIMUM UNLESS NOTED OTHERWISE ON PLANS/DETAILS). TIE AT 8'-0" VERTICALLY, WITH SINGLE WIRE LOOP TIE OR EQUIVALENT. DOWEL ALL REINFORCING TO FOUNDATION WITH DOWELS TO MATCH AND LAP VERTICAL WALL OR COLUMN REINFORCING. 2.CONTROL JOINTS: UNLESS NOTED OTHERWISE ON THE PLANS, PLACE CONTROL JOINTS IN MASONRY WALLS SUCH THAT NO STRAIGHT RUN OF WALL EXCEEDS 24'-0". CONTROL JOINTS SHALL NOT OCCUR AT WALL CORNERS, INTERSECTIONS, ENDS, WITHIN 24" OF CONCENTRATED POINTS OF BEARING OR JAMBS, OR OVER OPENINGS UNLESS SPECIFICALLY SHOWN ON THE STRUCTURAL DRAWINGS. 3.HORIZONTAL REINFORCING: (MINIMUM UNLESS NOTED OTHERWISE ON PLANS/DETAILS) ONE #5 BAR IN CENTER OF 16 INCH DEEP MINIMUM CONTINUOUS GROUTED BOND BEAM AT ELEVATED FLOOR AND ROOF LINES. FOR 8 INCH THICK WALLS, ONE #5 BAR IN CENTER OF 8 INCH DEEP CONTINUOUS GROUTED BOND BEAM AT INTERVALS NOT TO EXCEED 48 INCHES ON CENTER AND AT TOP OF PARAPET OR FREE STANDING WALLS. FOR 12 INCH THICK WALLS, TWO #5 BARS IN CENTER OF 8 INCH DEEP CONTINUOUS GROUTED BOND BEAM AT INTERVALS NOT TO EXCEED 48 INCHES ON CENTER AND AT TOP OF PARAPET OR FREE STANDING WALLS. HORIZONTAL BARS AT TOP OF PARAPET OR FREE STANDING WALLS SHALL BE PLACED 8 INCHES DOWN FROM THE TOP IN AN UPSIDE DOWN BOND BEAM BLOCK. PLACE HORIZONTAL BARS CONTINUOUS THROUGH CONTROL JOINTS. PROVIDE BENT BARS PER TYPICAL DETAILS, TO MATCH HORIZONTAL BOND BEAM REINFORCING, AT CORNERS AND WALL INTERSECTION TO MAINTAIN BOND BEAM CONTINUITY. 4.TENSION LAP SPLICES OF REINFORCING STEEL IN MASONRY SHALL BE AS FOLLOWS: REBAR SIZE STANDARD LAP RETAINING WALLS (AT FACE OF WALL) #4 24"30" #5 30"46" #6 43"55" #7 60"64" #8 72"72" 5.REINFORCING PLACEMENT TOLERANCES: ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO CENTER OF STEEL. TOLERANCES FOR PLACEMENT OF VERTICAL REINFORCING SHALL BE (±) 12" PERPENDICULAR TO WALL AND (±) 2" ALONG THE LENGTH OF THE WALL. PROVIDE 12" CLEARANCE BETWEEN MASONRY UNITS AND REINFORCING, AND REINFORCING RUNNING IN THE SAME DIRECTION. LAPS MAY BE BESIDE OR OVER THE REINFORCING BEING SPLICED. 6.BLOCK QUALITY: CONCRETE BLOCK SHALL BE LIGHTWEIGHT LOAD-BEARING CONCRETE MASONRY UNITS CONFORMING TO ASTM 90 WITH A MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI. USE BOND BEAM UNITS AT HORIZONTAL REINFORCING. 7.MORTAR: MORTAR MIX SHALL CONFORM TO REQUIREMENTS OF THE ASTM C270 AND ASTM C780 STANDARDS, TYPE M OR S. 8.GROUT: GROUT SHALL CONFORM TO REQUIREMENTS OF ASTM C476. USE SUFFICIENT WATER FOR GROUT TO FLOW INTO ALL JOINTS OF THE MASONRY WITHOUT SEGREGATION. GROUT SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. ALL CELLS IN CONCRETE BLOCKS CONTAINING REINFORCING SHALL BE FILLED SOLID WITH GROUT. ALL MASONRY BELOW FINISHED FLOOR OR GRADE SHALL BE GROUTED SOLID. ALL GROUT SHALL BE MECHANICALLY VIBRATED. GROUT LIFTS OF 5 FEET OR LESS IS RECOMMENDED. FOR HIGHER GROUT LIFTS, CLEANOUTS (3"x3") AT THE BOTTOM OF ALL VERTICALLY REINFORCED CELLS SHALL BE PROVIDED. IN ADDITION, MECHANICAL DEVICES SHALL BE USED TO POSITION AND SECURE REINFORCING WHEN GROUT LIFTS EXCEED 5 FEET IN HEIGHT. IN SOLID GROUTED MASONRY, CLEANOUTS SHALL NOT BE SPACED MORE THAN 32" O.C. 9.BLOCK CONSTRUCTION: ALL BLOCKS SHALL BE PLACED IN RUNNING BOND CONSTRUCTION (UNLESS OTHERWISE NOTED) WITH ALL VERTICAL CELLS IN ALIGNMENT. 10.MISCELLANEOUS LINTELS: FOR MISCELLANEOUS OPENINGS (4'-8" OR LESS) NOT SHOWN ON PLANS OR IN A SCHEDULE, BUT REQUIRED BY OTHER DISCIPLINES (MECHANICAL, ELECTRICAL, PLUMBING, ETC.) THE FOLLOWING OPTIONS MAY BE USED IN 8" MASONRY WALLS. OPTION #1: GROUTED REINFORCED MASONRY LINTEL: REINFORCE WITH (2) #4 HORIZONTAL BARS IN BOTTOM OF BOND BEAM OR LINTEL BLOCK AND SHALL BE GROUTED SOLID TO A MINIMUM DEPTH OF 12 INCHES. ALL LINTEL REINFORCING AND GROUT SHALL EXTEND 16 INCHES PAST JAMBS. OPTION #2: DOUBLE ANGLE LINTELS: USE (2) L312X312X14 BACK-TO-BACK. PROVIDE 12" MINIMUM OF GROUT OVER LINTELS. BEARING FOR STEEL ANGLE LINTELS SHALL BE 4" (±) 1" AT EACH JAMB. OPTION #3: POWERS STEEL LINTEL: PS8-8. GROUT LINTEL 8" DEEP. BEARING FOR POWERS STEEL LINTELS SHALL BE 4" (±) 1" AT EACH JAMB. THESE LINTELS, OR THE OPENING THEY SPAN, SHALL NOT BE PLACED SO AS TO INTERFERE WITH THE REQUIREMENTS OF OTHER STRUCTURAL ELEMENTS (I.E. BOND BEAMS, LINTELS, CONTROL JOINTS, CONCENTRATED POINTS OF BEARING, ETC.) WITHOUT THE PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. SOLID GROUT SHALL BE PROVIDED BETWEEN WEBS AND MASONRY FACE SHELLS FOR FULL LENGTH OF ALL STEEL LINTELS. MORTAR MAY BE USED FOR GROUT FOR THIS PURPOSE ONLY. FACE UNITS, SOAPS, ROMANS, ETC., SHALL BE LAID WITH FULL HEAD AND BED JOINTS. FOR ADDITIONAL INFORMATION AT OPENINGS IN MASONRY WALLS, SEE TYPICAL DETAILS. STEEL: 1.MATERIALS: ROLLED W SHAPES, SHALL CONFORM TO ASTM A992 (FY=50 KSI). ALL OTHER STRUCTURAL STEEL SHAPES, ROLLED SECTIONS, BARS AND PLATES SHALL CONFORM TO ASTM A36 (FY = 36 KSI). ALL PIPE STEEL SHALL BE ASTM A501 (FY = 36 KSI) OR ASTM A53, TYPE E OR S, GRADE B (FY = 35 KSI). ALL TUBULAR STEEL SHALL BE ASTM A500 (FY = 46 KSI). 2.ALL BOLTS AND STUDS SHALL BE ASTM A307, UNLESS NOTED OTHERWISE. ALL EXPANSION BOLTS TO HAVE CURRENT ICC REPORT RATING FOR MATERIAL INTO WHICH INSTALLATION TAKES PLACE. HEADED STUDS SHALL CONFORM TO ALL REQUIREMENTS OF THE LATEST EDITION OF THE "RECOMMENDED PRACTICES FOR STUD WELDING" AND THE "STRUCTURAL WELDING CODE" PUBLISHED BY AWS. ALL BOLTS, ANCHOR BOLTS, EXPANSION BOLTS, ETC. SHALL BE INSTALLED WITH STEEL WASHERS AT FACE OF WOOD OR AT SLOTTED HOLES IN STEEL SECTIONS. 3.ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, LATEST EDITION. 4.WELDING SHALL BE BY WELDERS HOLDING VALID CERTIFICATES AND HAVING CURRENT EXPERIENCE IN THE TYPE OF WELD SHOWN ON THE DRAWINGS OR NOTES. ALL WELDING SHALL USE E70 SERIES LOW HYDROGEN RODS UNLESS NOTED OTHERWISE. ALL WELDING PER LATEST AMERICAN WELDING SOCIETY STANDARDS. ALL WELDS ON DRAWINGS ARE SHOWN AS SHOP WELDS. CONTRACTOR MAY SHOP WELD OR FIELD WELD AT HIS DISCRETION. ALL FULL PENETRATION WELDS SHALL BE TESTED AND CERTIFIED BY AN INDEPENDENT TESTING LABORATORY. 5.STEEL TO STEEL BOLTED CONNECTIONS: HIGH STRENGTH BOLTS SHALL BE ASTM A325N AND SHALL BE INSTALLED AS BEARING-TYPE CONNECTIONS WITH THREADS INCLUDED IN SHEAR PLANE (TYPE "N" CONNECTION UNLESS NOTED OTHERWISE). BOLTS MAY BE TIGHTENED USING ANY AISC APPROVED METHOD. 6.DRYPACK SHALL BE 5,000 PSI FIVE STAR NON-SHRINK GROUT OR EQUIVALENT. INSTALL DRYPACK UNDER BEARING PLATES BEFORE FRAMING MEMBER IS INSTALLED. AT COLUMNS, INSTALL DRYPACK UNDER BASE PLATES AFTER COLUMN HAS BEEN PLUMBED BUT PRIOR TO FLOOR OR ROOF INSTALLATION. CAST IN PLACE CENTERLINE CENTERLINE OF BEAM CENTERLINE OF COLUMN CENTERLINE OF WALL CLEAR CONCRETE CONCRETE CONTROL JOINT CONCRETE SAWCUT JOINT CONCRETE MASONRY UNIT CONNECTION CONTINUOUS DEAD LOAD DOWN DRAWING(S) EQUAL EQUIPMENT EXPANSION JOINT EACH WAY FINISHED FLOOR FACE OF STEEL FACE OF WALL GAUGE GALVANIZED GENERAL STRUCTURAL NOTES CENTERLINE OF FOOTING FACE OF MEMBER EXPANSION BOLT EDGE OF SLAB DIAMETER GALV GSN DN. DWG(S) EQ EQUIP EXP. JT (E.J.) E.W. F.F. F.O.S. F.O.W. GA F.O.M. EXP. BOLT E.O.S. Ø OR DIA. C.I.P. C L C.L.B. C.L.C. C.L.W. CLR CONC C.C.J. C.S.J. C.M.U. CONN. CONT D L C.L.F. W/WITH W/O WITHOUT T.O.P. U.N.O. W.W.F. TYP VERT T.O.S. T.O.W. T.O.D. T.O.F. T.O.L. T.O.M. STD T.O.B. T L SLH SLV SIM SQ PSF PSI REINF PREFAB OPP P.C. PLF N.T.S. O.C. O.F.W. TOP OF FOOTING UNLESS NOTED OTHERWISE WELDED WIRE FABRIC TOP OF MASONRY TOP OF PLATE TOP OF STEEL TOP OF WALL TYPICAL VERTICAL STANDARD TOP OF BEAM TOP OF DECK TOP OF LEDGER TOTAL LOAD OUTSIDE FACE OF WALL PRECAST CONCRETE POUNDS PER LINEAR FOOT POUNDS PER SQUARE INCH SHORT LEG VERTICAL SHORT LEG HORIZONTAL REINFORCING SIMILAR SQUARE NOT TO SCALE ON CENTER OPPOSITE PREFABRICATED AGGREGATE BASE COURSE AIR CONDITIONER ABOVE FINISHED FLOOR ALTERNATE ANCHOR BOLT AT (MEASUREMENT) BEAM BOTTOM OF BEAM BOTTOM OF DECK BEARING BELOW FINISHED FLOOR BOTTOM OF FOOTING A.B.C. A/C A.F.F. ALT A.B. @ BM B.O.B. B.O.D. BRG B.F.F B.O.F. ABBREVIATIONS LBS (#) MFR('S) M.C.J. MECH N/A LLV LLH HORIZ K(KIP) L L LONG LEG VERTICAL MANUFACTURER('S) MASONRY CONTROL JOINT NOT APPLICABLE LONG LEG HORIZONTAL POUNDS MECHANICAL HORIZONTAL 1000 POUNDS LIVE LOAD EXISTING(E) MIN MINIMUM MAX MAXIMUM POUNDS PER SQUARE FOOT GLUED-LAMINATED BEAMGLB PFT PREFAB FLOOR TRUSSES PRT PREFAB ROOF TRUSSES I.F.W.INSIDE FACE OF WALL PT PRESSURE TREATED CONCRETE COLUMNC.C. RME ROOF MOUNTED EQUIPMENT SHEET INDEX SHEET DESCRIPTION DETAILS S1.0 GENERAL STRUCTURAL NOTES --- S1.1 GENERAL STRUCTURAL NOTES --- S1.2 TYPICAL DETAILS T-SERIES S1.3 TYPICAL DETAILS T-SERIES S2.0 FOUNDATION AND ROOF FRAMING PLAN --- S3.0 DETAILS 100 - 200 SERIES JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com DMEKBBIF21-094 PRO F E S S I O N A L ENG I N E E R S T ATE O F I D A H O A 6/ 2 / 2 1 14 1 3 4 D VID B . P O R T E R L I C E N SED STRUCTURAL ENGINEERING GENERAL STRUCTURAL NOTES -CONTINUED - (APPLY UNLESS NOTED OTHERWISE ON PLANS/DETAILS) SPECIAL INSPECTION ITEMS: 1.THE OWNER OR THE OWNER'S AUTHORIZED AGENT, OTHER THAN THE CONTRACTOR, SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TO PROVIDE SPECIAL INSPECTIONS AND TESTS DURING CONSTRUCTION ON THE TYPES OF WORK SPECIFIED PER IBC SECTION 1705 AND IDENTIFY THE APPROVED AGENCIES TO THE BUILDING OFFICIAL. SPECIAL INSPECTIONS ARE REQUIRED AS FOLLOWS: 2.QUALITY ASSURANCE PROGRAM: A.THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED TO BE CERTAIN IT CONFORMS WITH THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. B.THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, AND TO THE STRUCTURAL ENGINEER OF RECORD. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, TO THE DESIGN AUTHORITY AND THE BUILDING OFFICIAL. OPEN-WEB STEEL JOISTS AND JOIST GIRDERS (IBC TABLE 1705.2.3) TYPE CONTINUOUS SPECIAL INSPECTION PERIODIC SPECIAL INSPECTION A. END CONNECTIONS - WELDING OR BOLTED -X B. BRIDGING - HORIZONTAL OR DIAGONAL - 1. STANDARD BRIDGING -X 2. BRIDGING THAT DIFFERS FROM THE SJI SPECIFICATIONS LISTED IN SECTION 2207.1 X 1. OPEN-WEB STEEL JOISTS AND JOIST GIRDERS. MASONRY - LEVEL B (TMS 402/ACI 530/ASCE 5 TABLE 3.1.2) VERIFICATION AND INSPECTION CONTINUOUS SPECIAL INSPECTION PERIODIC SPECIAL INSPECTION 1. VERIFY COMPLIANCE WITH THE APPROVED SUBMITTALS -X 2. AS MASONRY CONSTRUCTION BEGINS, VERIFY THAT THE FOLLOWING ARE IN COMPLIANCE: A. PROPORTIONS OF SITE-PREPARED MORTAR X B. CONSTRUCTION OF MORTAR JOINTS X C. GRADE AND SIZE OF PRESTRESSING TENDONS AND ANCHORAGES X D. LOCATION OF REINFORCEMENT, CONNECTORS, AND PRESTRESSING TENDONS AND ANCHORAGES X E. PRESTRESSING TECHNIQUE X F. PROPERTIES OF THIN-BED MORTAR FOR AAC MASONRY X X 3. PRIOR TO GROUTING, VERIFY THAT THE FOLLOWING ARE IN COMPLIANCE: A. GROUT SPACE X B. GRADE, TYPE, AND SIZE OF REINFORCEMENT AND ANCHOR BOLTS, AND PRESTRESSING TENDONS AND ANCHORAGES X C. PLACEMENT OF REINFORCEMENT, CONNECTORS, AND PRESTRESSING TENDONS AND ANCHORAGES X D. PROPORTIONS OF SITE-PREPARED GROUT AND PRESTRESSING GROUT FOR BONDED TENDONS X E. CONSTRUCTION OF MORTAR JOINTS X 4. VERIFY DURING CONSTRUCTION: A. SIZE AND LOCATION OF STRUCTURAL ELEMENTS X B. TYPE, SIZE, AND LOCATION OF ANCHORS, INCLUDING OTHER DETAILS OF ANCHORAGE OF MASONRY TO STRUCTURAL MEMBERS, FRAMES, OR OTHER CONSTRUCTION X C. WELDING OF REINFORCEMENT X D. PREPARATION, CONSTRUCTION, AND PROTECTION OF MASONRY DURING COLD WEATHER (TEMPERATURE BELOW 40°F) OR HOT WEATHER (TEMPERATURE ABOVE 90°F) X E. APPLICATION AND MEASUREMENT OF PRESTRESSING FORCE X F. PLACEMENT OF GROUT AND PRESTRESSING GROUT FOR BONDED TENDONS IS IN COMPLIANCE X G. PLACEMENT OF ACC MASONRY UNITS AND CONSTRUCTION OF THIN-BED MORTAR JOINTS X X 5. OBSERVE PREPARATION OF GROUT SPECIMENS, MORTAR SPECIMENS, AND/OR PRISMS X ANCHORAGE TO CONCRETE: ADHESIVE ANCHORS: HILTI HIT-HY 200 PER ICC ESR-3187 HILTI HIT-RE 500 V3 PER ICC ESR-3814 SIMPSON AT-XP PER IAPMO ER-263 SIMPSON SET-XP PER ICC ESR-2508 MECHANICAL ANCHORS: HILTI KWIK HUS PER ICC ESR-3027 HILTI KWIK BOLT-TZ EXPANSION ANCHORS PER ICC ESR-1917 SIMPSON TITEN HD PER ICC ESR-2713 SIMPSON STRONG BOLT-2 PER ICC ESR-3037 ADHESIVES: HILTI HIT-HY 200 PER ICC ESR-3187 HILTI HIT-RE 500 V3 PER ICC ESR-3814 SIMPSON AT-XP PER IAPMO ER-263 SIMPSON SET-XP PER ICC ESR-2508 ADHESIVE ANCHORS: HILTI HIT-HY 200 PER ICC ESR-3963 SIMPSON AT-XP PER IAPMO ER-281 SIMPSON SET PER ICC ESR-1772 MECHANICAL ANCHORS: HILTI KWIK BOLT-3 EXPANSION ANCHORS PER ICC ESR-1385 HILTI KWIK BOLT-TZ EXPANSION ANCHORS PER ICC ESR-3785 SIMPSON TITEN HD PER ICC ESR-1056 SIMPSON STRONG BOLT-2 PER IAPMO ER-240 ADHESIVE ANCHORS: HILTI HIT-HY 70 MASONRY ADHESIVE ANCHORING SYSTEM PER ICC ESR-3963 SIMPSON AT-XP PER IAPMO ER-281 SIMPSON SET PER ICC ESR-1772 2.SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO USE. CONTRACTOR SHALL PROVIDE CALCULATIONS DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERFORMANCE VALUES OF THE SPECIFIED PRODUCT. SUBSTITUTIONS WILL BE EVALUATED BY THEIR HAVING AN ICC ESR OR IAPMO ER SHOWING COMPLIANCE WITH THE RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE, INSTALLATION CATEGORY, AND AVAILABILITY OF COMPREHENSIVE INSTALLATION INSTRUCTIONS. ADHESIVE ANCHOR EVALUATION WILL ALSO CONSIDER CREEP, IN-SERVICE TEMPERATURE AND INSTALLATION TEMPERATURE. 3.INSTALL THE ANCHORS PER THE MANUFACTURER INSTRUCTIONS, AS INCLUDED IN THE ANCHOR PACKAGING. 4.THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER'S REPRESENTATIVE TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. THE STRUCTURAL ENGINEER OF RECORD MUST RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR'S PERSONNEL WHO INSTALL ANCHORS ARE TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING ANCHORS. 5.ANCHOR CAPACITY IS DEPENDANT UPON SPACING BETWEEN ADJACENT ANCHORS AND PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL ANCHORS IN ACCORDANCE WITH SPACING AND EDGE CLEARANCES INDICATED ON THE DRAWINGS. POST-INSTALLED ANCHORS: 1.EXCEPT WHERE INDICATED ON THE DRAWINGS, POST-INSTALLED ANCHORS SHALL CONSIST OF THE FOLLOWING ANCHOR TYPES. ALL ANCHORS ARE TO BE INSTALLED PER THE MANUFACTURERS RECOMMENDATIONS. VERIFICATION AND INSPECTION OF STRUCTURAL STEEL (PER AISC 360-CHAPTER N) VERIFICATION AND INSPECTION OBSERVE PERFORM 1. INSPECTION TASKS PRIOR TO WELDING (TABLE N5.4-1) A. WELDING PROCEDURE SPECIFICATIONS (WPSS) AVAILABLE X B. MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE X C. MATERIAL IDENTIFICATION (TYPE/GRADE)X D. WELDER IDENTIFICATIONS SYSTEM (THE FABRICATOR OR ERECTOR, AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY WHICH A WELDER WHO HAS WELDED A JOINT OR MEMBER CAN BE IDENTIFIED. (STAMPS, IF USED, SHALL BE THE LOW STRESS TYPE) X E. FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY), JOINT PREPARATION, DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL), CLEANLINESS (CONDITION OF STEEL SURFACES), TACKING (TACK WELD QUALITY AND LOCATION) , BACKING TYPE AND FIT (IF APPLICABLE) X F. CONFIGURATION AND FINISH OF ACCESS HOLES X G. FIT-UP OF FILLET WELDS, DIMENSIONS (ALIGNMENT, GAPS AT ROOT), CLEANLINESS (CONDITION OF STEEL SURFACES) TACKING (TACK WELD QUALITY AND LOCATION) X H. CHECK WELDING EQUIPMENT X 2. INSPECTION TASKS DURING WELDING (TABLE N5.4-2) A. USE OF QUALIFIED WELDERS X B. CONTROL AND HANDLING OF WELDING CONSUMABLES, PACKAGING, EXPOSURE CONTROL X C. NO WELDING OVER CRACKED TACK WELDS X D. ENVIRONMENTAL CONDITIONS, WIND SPEED WITHIN LIMITS, PRECIPITATION AND TEMPERATURE X E. WPS FOLLOWED, SETTINGS ON WELDING EQUIPMENT, TRAVEL SPEED, SELECTED WELDING MATERIALS, SHIELDING GAS TYPE/FLOW RATE, PREHEAT APPLIED, INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.), PROPER POSITION (F, V, H, OH) X F. WELDING TECHNIQUES, INTERPASS AND FINAL CLEANING, EACH PASS WITHIN PROFILE LIMITATIONS, EACH PASS MEETS QUALITY REQUIREMENTS X 3. INSPECTION TASKS AFTER WELDING (TABLE N5.4-3) A. WELDS CLEANED X B. SIZE LENGTH AND LOCATION OF WELDS X C. WELDS MEET VISUAL ACCEPTANCE CRITERIA, CRACK PROHIBITION, WELD/BASE-METAL FUSION, CRATER CROSS SECTION, WELD PROFILES, WELD SIZE, UNDERCUT, POROSITY X D. ARC STRIKES X E. K-AREA (WHEN WELDING OF DOUBLER PLATES, CONTINUITY PLATES OR STIFFENERS HAS BEEN, PERFORMED IN THE K-AREA, VISUALLY INSPECT THE WEB K-AREA FOR CRACKS WITHIN 3 IN. (75 MM) OF THE WELD). X F. BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED)X G. REPAIR ACTIVITIES X H. DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER X VERIFICATION AND INSPECTION OF STEEL DECK (PER SDI QA/QC) VERIFICATION AND INSPECTION OBSERVE PERFORM 1. INSPECTION OR EXECUTION TASKS PRIOR TO DECK PLACEMENT (TABLE 1.1) A. VERIFY COMPLIANCE OF MATERIALS (DECK AND ALL DECK ACCESSORIES) WITH CONSTRUCTION DOCUMENTS, INCLUDING PROFILES, MATERIAL PROPERTIES, AND BASE METAL THICKNESS X B. DOCUMENT ACCEPTANCE OR REJECTION OF DECK AND DECK ACCESSORIES X 4. INSPECTION TASKS PRIOR TO BOLTING (TABLE N5.6-1) A. MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS X B. FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS X C. PROPER FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT LENGTH IF THREADS ARE TO BE EXCLUDED FROM SHEAR PLANE) X D. PROPER BOLTING PROCEDURE SELECTED FOR JOINT DETAIL X E. CONNECTION ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE CONDITION AND HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE REQUIREMENTS X F. PRE-INSTALLED VERIFICATION TESTING BY INSTALLATION PERSONNEL OBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED X G. PROPER STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND OTHER FASTENER COMPONENTS X 5. INSPECTION TASKS DURING BOLTING (TABLE N5.6-2) A. FASTENER ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALL HOLES AND WASHERS (IF REQUIRED) ARE POSITIONED AS REQUIRED X B. JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONING OPERATION X C. FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM ROTATING X D. FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARDS THE FREE EDGES X 6. INSPECTION TASKS AFTER BOLTING (TABLE N5.6-3) A. DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS X 7. INSPECTION OF STEEL ELEMENTS OF COMPOSITE CONSTRUCTION PRIOR TO CONCRETE PLACEMENT (TABLE N6.1) A. PLACEMENT AND INSTALLATION OF STEEL DECK X B. PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORS X C. DOCUMENT ACCEPTANCE OR REJECTION OF STEEL ELEMENTS X 8. INSPECTOR SHALL BE ON PREMISES FOR INSPECTION DURING THE PLACEMENT OF ANCHOR RODS AND OTHER EMBEDMENTS SUPPORTING STRUCTURAL STEEL (SECTION N5.7) X 2. INSPECTION OR EXECUTION TASKS AFTER TO DECK PLACEMENT (TABLE 1.2) A. VERIFY COMPLIANCE OF DECK AND ALL DECK ACCESSORIES INSTALLATION WITH CONSTRUCTION DOCUMENTS X B. VERIFY DECK MATERIALS ARE REPRESENTED BY THE MILL CERTIFICATIONS THAT COMPLY WITH THE CONSTRUCTION DOCUMENTS X C. DOCUMENT ACCEPTANCE OR REJECTION OF INSTALLATION OF DECK AND DECK ACCESSORIES X 3. INSPECTION OR EXECUTION TASKS PRIOR TO WELDING, (TABLE 1.3) A. WELDING PROCEDURE SPECIFICATIONS (WPS) AVAILABLE X B. MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE X C. MATERIAL IDENTIFICATION (TYPE/GRADE)X D. CHECK WELDING EQUIPMENT X 4. INSPECTION OR EXECUTION TASKS DURING WELDING (TABLE 1.4) A. USE OF QUALIFIED WELDERS X B. CONTROL AND HANDLING OF WELDING CONSUMABLES X C. ENVIRONMENTAL CONDITIONS (WIND SPEED, MOISTURE, TEMPERATURE)X D. WPS FOLLOWED X 5. INSPECTION OR EXECUTION TASKS AFTER WELDING (TABLE 1.5) A. VERIFY SIZE AND LOCATION OF WELDS, INCLUDING SUPPORT, SIDELAP, AND PERIMETER WELDS X B. WELDS MEET VISUAL ACCEPTANCE CRITERIA X C. VERIFY REPAIR ACTIVITIES X D. DOCUMENT ACCEPTANCE OR REJECTION OF WELDS X 6. INSPECTION OR EXECUTION TASKS PRIOR TO MECHANICAL FASTENING (TABLE 1.6) A. MANUFACTURER INSTALLATION INSTRUCTIONS AVAILABLE, FOR MECHANICAL FASTENERS X B. PROPER TOOLS AVAILABLE FOR FASTENER INSTALLATION X C. PROPER STORAGE FOR MECHANICAL FASTENERS X 7. INSPECTION OR EXECUTION TASKS DURING MECHANICAL FASTENING (TABLE 1.7) A. FASTENERS ARE POSITIONED AS REQUIRED X B. FASTENERS ARE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS X 8. INSPECTION OR EXECUTION TASKS AFTER MECHANICAL FASTENING (TABLE 1.7) A. CHECK SPACING, TYPE, AND INSTALLATION OF SUPPORT FASTENERS X B. CHECK SPACING, TYPE, AND INSTALLATION OF SIDELAP FASTENERS X C. CHECK SPACING, TYPE, AND INSTALLATION OF PERIMETER FASTENERS X D. VERIFY REPAIR ACTIVITIES X E. DOCUMENT ACCEPTANCE OR REJECTION OF MECHANICAL FASTENERS X ANCHORAGE TO SOLID GROUTED MASONRY: ANCHORAGE TO HOLLOW/MULTI-WYTHE MASONRY: REBAR DOWELING TO CONCRETE: KEYNOTES: 1.FINISHED GRADE WHERE OCCURS 2.DO NOT EXCAVATE A TRENCH CLOSER THAN A 45 DEGREE ANGLE TO BELOW BOTTOM FOOTING OR FOUNDATION 3.BOTTOM OF CONCRETE FOOTING 4.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPE OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T1 TRENCH PARALLEL TO CONTINUOUS STRIP FOOTING TD01 NO SCALE 1 1 4 3 2 1 KEYNOTES: 1.CONCRETE FOOTING 2.SLEEVE - PROVIDE 12" MINIMUM CLEARANCE AROUND PIPE OR CONDUIT 3.PIPE OR CONDUIT 4.CONCRETE FILL TO BE PLACED BEFORE FOOTING IS POURED - FORM SAME AS FOOTING AND POUR FULL WIDTH OF PIPE TRENCH 5.STEM WALL NOTE: A.NO PIPE SHALL PASS THRU FOOTING OR UNDER COLUMN FOOTINGS. FOR TRENCHES GREATER THAN 3'-6" BELOW BOTTOM OF FOOTING, SEE PIPE PASSING BELOW WALL FOOTING DETAIL. T2 PIPE PASSING UNDER WALL FOOTING IN SHALLOW TRENCH TD02 NO SCALE 6" M I N 8" M I N 3' - 0 " M A X 8" MIN A SECTIONA 5 1 2 3 4 5 1 2 3 4 KEYNOTES: 1.STEM WALL 2.CONCRETE FOOTING 3.1'-6" MAXIMUM - WHERE TRENCH EXCEEDS 1'-6" NOTIFY STRUCTURAL ENGINEER PRIOR TO PLACEMENT OF FOOTINGS 4.BACKFILL AND RECOMPACT TRENCH PER SOILS REPORT AND SPECIFICATIONS 5.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPES OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 3' - 1 " O R G R E A T E R FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T3 PIPE PASSING BELOW FOOTING IN DEEP TRENCH TD03 NO SCALE 5 3 2 1 44 1 KEYNOTES: 1.SLOPED FINISH GRADE 2.MINIMUM FOOTING DEPTH PER G.S.N. - 12" MINIMUM 3.DEEPEN FOOTING AS REQUIRED TO ACCOUNT FOR SLOPED GRADE 4.CONCRETE FOOTING NOTE: A.FOR ADDITIONAL INFORMATION, SEE PLANS AND DETAILS 5'-0" T4 TYPICAL DETAIL FOR FOUNDATION EMBEDMENT TD04 NO SCALE 1 2 3 4 KEYNOTES: 1.CORNER DOWELS TO MATCH HORIZONTAL REINFORCEMENT 2.CONCRETE WALL WITH REINFORCEMENT 18" MIN LAP SPLICE (TYP) T5 TYPICAL CONCRETE CORNER TD05 NO SCALE 2 1 KEYNOTES: 1.CONCRETE SLAB ON GRADE 2.CONT KEYED JOINT 3.SAWCUT 18" WIDE x 1 4 SLAB THICKNESS IN DEPTH - CUT SHALL BE MADE SOON ENOUGH TO PREVENT SHRINKAGE CRACKING, BUT NOT SO SOON AS TO CAUSE SPALLING OF THE CONCRETE WHILE SAWING. WORK MUST BE COMPLETE WITHIN 16 HOURS OF CONCRETE PLACEMENT. NOTE: A.KEYED JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING PLACEMENT UNLESS SPECIFICALLY NOTED ON THE PLANS. B."TOOL WET JOINT", "ZIP STRIP", ETC SHALL MATCH SAWCUT REQUIREMENTS 12"6"6"12" SAWCUT JOINT KEYED JOINT T6 CONTROL JOINTS IN CONCRETE SLAB ON GRADE TD07 NO SCALE 1 3 1 2 T7 TYPICAL REINFORCING DETAILS TD10 NO SCALE 6 MIN BAR OFFSET BAR CLEARANCE SPLICE DETAIL BEND & HOOK DETAILS COLUMN TIES BEAM STIRRUPS "d" 45° "d" "d" 1 8 8 KEYNOTES: 1.LAP - SEE G.S.N. 2.MAXIMUM 15 LAP BUT NOT MORE THAN 6" 3.WIRE TIES 4.1d (1" MINIMUM) 5.RADIUS = 3d FOR BARS NOT OVER #8; 4d FOR #9, #10, AND #11 BARS; 5d FOR #14 AND #18 BARS, 5d FOR ALL GRADE 40 BARS WITH 180 DEGREE HOOK 6.4D (4" MINIMUM) 7.12d (90 DEGREE HOOK) 8.6d (4" MINIMUM) 9.135 DEGREE BEND 10.BEND AROUND 112" PIN FOR #3 BARS. BEND AROUND 2" PIN FOR #4 BARS. BEND AROUND 212" PIN FOR #5 BARS. 3 1 2 4 6 7 5 55 5 99 10 10 6 8 KEYNOTES: 1.CONCRETE FOOTING, SEE PLAN 2.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 3.#4 DOWEL TO MATCH FOOTING REINFORCEMENT 4.#4 DOWEL TO LAP AND MATCH WALL REINFORCEMENT NOTE: A.FOR ITEMS SHOWN BUT NOT KEYNOTED, SEE FOUNDATION DETAILS B.WHERE NEW FOOTING TIES INTO EXISTING FOOTING, DRILL AND EPOXY 24" LONG DOWELS INTO EXISTING, PROVIDE 4" MIN EMBEDMENT2 3" CLR 3" CL R 24" 24" 1 3 2 1 4 24" 24" T8 CONCRETE FOOTING AT CONCRETE WALL TD12 NO SCALE NOTES: 1.TOP BARS ARE ANY HORIZONTAL BARS PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. 2.UNLESS NOTED OTHERWISE, LAP SPLICES IN CONCRETE BEAMS, SLABS AND WALLS SHALL BE CLASS "B" TENSION LAP SPLICES. BAR SIZE CLASS B TENSION SPLICE LENGTHS f'c = 3,000 PSI f'c = 4,000 PSI f'c = 5,000 PSI HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HORIZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS #3 12"12"12"12"12"12" #4 19"15"17"13"15"12" #5 29"23"26"20"23"18" #6 32"25"28"21"25"19" #7 54"41"47"36"42"32" #8 70"54"61"47"54"42" #9 89"68"77"59"69"53" #10 112"87"97"75"87"67" T9 STEEL REINFORCING LAP SPLICES IN CONCRETE TD14 NO SCALE T10 PLAN - CORNER AND END REINFORCING IN MASONRY WALLS TD45 NO SCALE KEYNOTES: 1.MASONRY WALL 2.BOND BEAM REINFORCING 3.CORNER BARS SAME SIZE AND SPACING AS HORIZONTAL REINFORCING - MINIMUM LAP PER G.S.N. 4.END #4 x 38" LONG (19" EACH LEG) HAIRPIN AT SAME SPACING AS HORIZONTAL REINFORCING INTERSECTION CORNER 1 332 2 1 2 1 1 2 3 4 2 1 END WALL T11 TYPICAL MASONRY LINTEL TD48 NO SCALE KEYNOTES: 1.CONTINUE STANDARD WALL REINFORCING THROUGH THE MASONRY LINTEL 2.SOLID GROUT ALL LINTELS AND 2'-0" MIN INTO ADJACENT WALLS 3.WALL REINFORCING TO EXTEND AND HOOK BOTTOM LINTEL REINFORCEMENT 4.MASONRY LINTELS REINFORCEMENT, SEE SCHEDULE 1 LI N T E L D E P T H SE E S C H E D U L E TY P I C A L M A S O N R Y WA L L A B O V E WIDTH NOTE: A.SEE GSN FOR SPECIAL INSPECTION REQUIREMENTS OF MASONRY LINTELS B.ANY BAR SPLICES SHALL HAVE A MINIMUM LENGTH OF 72 BAR DIA. C.PROVIDE 90° STANDARD HOOK WHERE HORIZONTAL REINFORCING DOES NOT EXTEND 2'-0" BEYOND OPENING 2 3 1 4" MA X T12 POST-INSTALLED ANCHORS IN MASONRY WALLS TD49 NO SCALE KEYNOTES: 1.MASONRY WALL, SEE PLAN 2.ANCHOR INSTALLATION NOT ALLOWED IN HATCHED AREAS, TYPICAL 114" MI N 2 1 11 4" MIN T13 PLAN - TYPICAL MASONRY JAMB TD51 NO SCALE KEYNOTES: 1.VERTICAL BAR, SEE PLAN 2.#3 36" LONG (18" EACH LEG) HAIRPIN AT HORIZONTAL BAR SPACING 3.TYPICAL HORIZONTAL BAR, SEE PLAN 4.JAMB LENGTH, SEE PLAN, SOLID GROUT 5.(2) #4 HORIZONTAL BARS AT 48" O.C. W/ HOOKS EACH END 1 2 3 4 4 2 " CL R 2 3 11 TYPE "A" TYPE "B" NOTES: A.PROVIDE FOUNDATION VERTICAL DOWEL TO MATCH AND LAP W/ VERTICAL JAMB REINFORCING OPENING OPENING TYPE "C" 4 OPENING 511 11 OPENING 2 " CL R TYP 3/16 CROSS BRIDGING HORIZONTAL BRIDGING KEYNOTES: 1.MASONRY WALL, SEE PLAN 2.L3x3x1 4" ANGLE TO RECEIVE BRIDGING W/ (1) 5 8"Øx6" LONG TITEN HD 3.STEEL JOIST, SEE PLAN 3 2 1 3/16 TYP 3/16 3/16 1 3 2 T14 TYPICAL JOIST BRIDGING AT MASONRY WALL TD64 NO SCALE 3/16 TYP TYP 3/16 1/4"± KEYNOTES: 1.ROOF FRAMING MEMBER 2.ANGLE 4"x4"x14" 3.FACE OF FRAMING MEMBER 1 1 2 3 2 4' - 0 " MA X 4'-0" MAX 6' - 6 " MA X TYP 3/16 T15 PLAN - TYPICAL OPENING IN ROOF FRAMING TD65 NO SCALE OPEN PRO F E S S I O N A L ENG I N E E R S T ATE O F I D A H O A 6/ 2 / 2 1 14 1 3 4 D VID B . P O R T E R L I C E N SED STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com DMEKBBIF21-094 T16 TYPICAL MASONRY WALL REINFORCING AROUND OPENINGS - ELEVATION T66 NO SCALE KEYNOTES: 1.8" DEEP BOND BEAM W/ (1) #5 CONTINUOUS AT TOP OF PARAPET 2.ROOF LINE 3.16" DEEP BOND BEAM W/ (2) #5 CONTINUOUS AT ROOF AND FLOOR LINES 4.PROVIDE 90° STANDARD HOOK WHERE LINTEL REINFORCING EXTENDS LESS THAN 24" BEYOND OPENING 5.TYPICAL CORNER OR JAMB VERTICAL BARS 6.PROVIDE (1) #5 HORIZONTAL BAR BELOW OPENINGS 7.TYPICAL WALL REINFORCING, SEE PLAN 8.FOUNDATION VERTICAL DOWEL, MATCH ALL VERTICAL WALL REINFORCING 9.LINTEL REINFORCING, SEE PLAN 10.FULL HEIGHT VERTICAL JAMB REINFORCING, SEE PLAN 11.SEE TYPICAL MASONRY LINTEL DETAIL 12.SEE TYPICAL MASONRY JAMB DETAIL NOTE: A.GROUT ALL CELLS CONTAINING REINFORCING. SEE PLAN FOR LOCATION OF WALLS REQUIRING FULL GROUTING B.SPECIAL INSPECTION REQUIRED, SEE GSN C.SEE PLAN AND CORRESPONDING DETAILS FOR LINTEL AND JAMB REINFORCING REQUIREMENTS 24" MIN TYP 24" MIN TYP 1 10 9 4 6 2 5 8 MI N L A P 12 11 11 12 OPEN OPEN 3 T17 TYPICAL SMALL OPENING IN STEEL DECK TD_SF10 NO SCALE 1/8 OPEN WEB RIB RIB KEYNOTES: 1.STEEL DECK, SEE PLAN 2.ANGLE SUPPORT L2x2x3 16" BELOW DECK, ANGLE MAY BE PLACED ON TOP OF DECK W/ PRIOR APPROVAL OF ARCHITECT 3.WELD 2" AT EACH RIB, TYPICAL NOTE: A.AN OPENING WHICH CUTS ONE WEB (4" MAX DIMENSION PERPENDICULAR TO RIBS), MAY BE CUT IN DECK WITHOUT ANY SPECIAL REINFORCING. B.AN OPENING WHICH CUTS TWO WEBS (8" MAX DIMENSION PERPENDICULAR TO RIBS), WILL REQUIRE ANGLE SUPPORT SHOWN ABOVE. C.ANY OPENING WHICH CUTS MORE THAN TWO WEBS, FRAME OPENING W/ TYPICAL ANGLE SUPPORT FRAME, SEE TYPICAL OPENING IN STEEL DECK DETAIL. A 3 SECTIONA TYPICAL DECK SECTION 2 2 1 1 2 T18 TYPICAL PIPE SLEEVE THROUGH ROOF DECK TD_SF11 NO SCALE PLAN VIEW KEYNOTES: 1.PIPE SLEEVE 2.18 GA PLATE W/ #10 SHEET METAL SCREWS AT 6' O.C., EACH WAY 3.METAL ROOF DECK, SEE PLAN 12" SQR < 4"Ø 24" SQR < 8"Ø 36" SQR < 12"Ø 1 23 2 T19 TYPICAL SPLICE IN CONTINUOUS STEEL CHORD/EDGE ANGLE TD_SF15 NO SCALE KEYNOTES: 1.STEEL CHORD/EDGE ANGLE - FOR SIZE AND LOCATION, SEE PLAN 2.8" LONG x 2"x3 8" THICK STEEL PLATES 1/2" M A X 1/4 TYP 1 1 2 2 KEYNOTES: 1.MASONRY WALL 2.CONTROL JOINT 3.CONTROL JOINT MATERIAL PER ARCHITECTURAL DRAWINGS AND SPECIFICATIONS 4.(1) VERTICAL BAR EACH SIDE IN SOLID GROUTED CELLS TO MATCH VERTICAL WALL REINFORCING 5.#3x36" LONG (18" EACH LEG) HAIRPIN AT HORIZONTAL BAR SPACING 6.TYPICAL HORIZONTAL BAR, SEE PLAN 7.EXTERIOR GRADE SEALANT OVER BACKER ROD NOTE: A.BOND BEAM BARS AT FLOOR AND ROOF LINES SHALL RUN CONTINUOUS THROUGH CONTROL JOINT 6 4 4 5 5 6 6 A PLANA T20 CONTROL JOINT IN MASONRY WALL TD52 NO SCALE 1 3 2 7 7 PRO F E S S I O N A L ENG I N E E R S T ATE O F I D A H O A 6/ 2 / 2 1 14 1 3 4 D VID B . P O R T E R L I C E N SED STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com DMEKBBIF21-094 J2 101 4" CONCRETE SLAB ON GRADE W/ #3 AT 24" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. (SEE GSN) PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME FINISH FLOOR = 100'-0" CONCRETE SLAB ON GRADE WF18 / W1 WF18 / W1 WF 1 8 / W 1 WF 1 8 / W 1 WF 1 8 / W 1 W3 W3 W2 W2 W2 11'-4" 30 ' - 8 " 9' - 4 " 8' - 0 " 3'-0" 3'-0" (E ) L L1 L1 L2 101 202 101 201 201 203 101 101 102 1 1 J2 J1J2 1 201 1 J2 J3 J3 J1 J2 204 J2 J1 J2 J1 22 GAGE VERCO PLB-36 DECK W/ HILTI HSN-24 PINS AT 36/7/4 PATTERN AND VSC2 AT 12" O.C. SIDE LAP CONNECTION ALL DECKING SHALL BE DOUBLE SPAN MIN. 10 K S T E E L J O I S T S AT 6 ' - 0 " O . C . (3 5 0 / 2 3 0 ) J3 J3 J2 WF18 / W1 3'-4" 48 ' - 0 " W2 202 15 ' - 4 " 5' - 8 1 4" 5' - 8 1 4" 250# VERIFY W/MECHANICAL W2 750# 2'-0" CJ WEIGHT (E ) L 2 2 SCALE: FOUNDATION PLAN 1/4" = 1'-0" PRO F E S S I O N A L ENG I N E E R S T ATE O F I D A H O A 6/ 2 / 2 1 14 1 3 4 D VID B . P O R T E R L I C E N SED STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com DMEKBBIF21-094 1.EPOXY HORIZONTAL REINFORCING FOR NEW WALL INTO EXISTING WALL W/ HILTI HIT-HY 200 EPOXY AND 4" MIN. EMBEDMENT 2.PROVIDE L4x4x14 BELOW PERIMETER OF RTU AND PROVIDE ANGLES AT PENETRATIONS IN ROOF PER "TYPICAL OPENING IN ROOF FRAMING" DETAIL PLAN KEYNOTESX FOOTING SCHEDULE NOTES: 1. FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. 2. FOR MINIMUM CLEARANCE (CLR) OF REINFORCING, SEE GENERAL STRUCTURAL NOTES (GSN). MARK LENGTH WIDTH THICKN ESS FOOTING REINFORCING REMARKS WF18 CONT 18"10"(2) #4 CONT BOTTOM STRIP FOOTING WALL (W) SCHEDULE MARK THICKNESS AND TYPE VERTICAL REINFORCING HORIZONTAL REINFORCING REMARKS W1 8" CONCRETE #4 AT 18" O.C.#4 AT 12" O.C.--- W2 8" MASONRY #5 AT 32" O.C.#5 AT 48" O.C.--- W3 8" MASONRY #5 AT 32" O.C.#5 AT 24" O.C.--- SCALE: ROOF FRAMING PLAN 1/4" = 1'-0" A.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. B.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. C.THE DEPTH OF FOOTING DIMENSION INDICATED IN THE G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS. D. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. E. WALLS WITH DASHED LINES DESIGNATE EXISTING WALLS. F.WF18, WF24, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS WALL FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. G.W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. H.L1, L2, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE OR MASONRY LINTEL. SEE LINTEL SCHEDULE FOR ADDITIONAL INFORMATION. I.J1, J2, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE OR MASONRY JAMB. SEE JAMB SCHEDULE FOR ADDITIONAL INFORMATION. J.CJ- AS SHOWN ON PLAN INDICATES A CONTROL JOINT IN A CONCRETE OR MASONRY WALL. SEE GSN AND TYPICAL DETAIL. JOINTS MAY BE SHOWN, BUT NOT NOTED ON THIS PLAN. SEE FOUNDATION PLAN FOR NOTED LOCATIONS. K.FOR SIDEWALK AND LANDING LOCATIONS, SEE ARCHITECTURAL DRAWINGS. L.FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION, M.FOR CLARITY, ALL ROOF OPENINGS MAY NOT BE SHOWN ON THE ROOF FRAMING PLAN. FOR EXACT SIZE, NUMBER AND LOCATION OF OPENINGS, SEE ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS. FOR FRAMING AT OPENINGS, SEE TYPICAL DETAILS. N. INDICATES HVAC EQUIPMENT ON ROOF OR IN ATTIC SPACE. SEE TYPICAL DETAILS FOR FRAMING INFORMATION. U.N.O XXXX# AT UNITS INDICATES ADDITIONAL DEAD LOAD THAT JOIST MANUFACTURER SHALL DESIGN FOR TO SUPPORT UNITS. U.N.O PROVIDE L4x4x14 AROUND PERIMETER OF UNIT AND ATTACH IN MANNER SIMILAR TO THAT SHOWN IN "TYPICAL OPENING IN ROOF FRAMING DETAIL" VERIFY EXACT SIZE AND WEIGHT OF EQUIPMENT ON ROOF WITH MECHANICAL DRAWINGS. PLAN NOTES LINTEL (L) SCHEDULE MARK SIZE REINFORCING L1 16" DEEP (1) #4 TOP AND BOTTOM L2 16" DEEP (2) #4 TOP AND BOTTOM JAMB (J) SCHEDULE SEE TYPICAL JAMB DETAIL FOR ADDITIONAL INFORMATION MARK REBAR AND QUANTITIES TYPE LENGTH REMARKS J1 (2) #5 A 8"REBAR CENTERED J2 (2) #5 B 16"REBAR EACH FACE J3 (4) #5 C 18"REBAR EACH FACE 101 MASONRY WALL AT FOUNDATION CM_S101 NO SCALE KEYNOTES: 1.MASONRY WALL, SEE PLAN 2.DOWEL TO MATCH VERTICAL MASONRY WALL REINFORCING SIZE AND SPACING 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3" CLR 3" CL R 2' - 6 " LA P M I N 2' - 0 " LA P M I N 8 7 6 8 1 2 5 4 3 KEYNOTES: 1.WALL BEYOND, SEE PLAN 2.#4 BENT DOWEL AT 18" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3" CLR 3" CL R 18" 18" 8 7 6 8 5 4 3 1 2 102 CONCRETE SLAB AT FOUNDATION CM_S103 NO SCALE 201 STEEL JOIST AT MASONRY WALL MS-SC216 NO SCALE KEYNOTES: 1.CONT L6x4x3/8 (LLV) W/ (1) 1/2" Ø EPOXY BOLT AND 5" MIN. EMBEDMENT AT 24" O.C. USE HILTI-HY 270 EPOXY SYSTEM 2.BOUNDARY ATTACHMENT, SEE PLAN 3.STEEL DECK, SEE PLAN 4.STEEL JOIST, SEE PLAN 5.MASONRY WALL, SEE PLAN 6.16" DEEP BOND BEAM W/ (2) #5 BARS CONTINUOUS 7.8" DEEP BOND BEAM W/ (1) #5 BAR CONTINUOUS AT TOP OF PARAPET 8.L2 12x2 12x14 BETWEEN EACH JOIST 9.CONT 2x PT PLATE W/ 1/2" Ø ANCHOR BOLTS AT 32" O.C. W/ 4" MIN. EMBEDMENT 5 6 7 1 2 3 4 202 STEEL JOIST AT MASONRY WALL MS-SC216 NO SCALE KEYNOTES: 1.CONT L3x3x1/4 W/ (1) 1/2" Ø EPOXY BOLT AND 5" MIN. EMBEDMENT AT 24" O.C. USE HILTI-HY 270 EPOXY SYSTEM. 2.BOUNDARY ATTACHMENT, SEE PLAN 3.STEEL DECK, SEE PLAN 4.STEEL JOIST, SEE PLAN 5.MASONRY WALL, SEE PLAN 6.16" DEEP BOND BEAM W/ (2) #5 BARS CONTINUOUS 7.8" DEEP BOND BEAM W/ (1) #5 BAR CONTINUOUS AT TOP OF PARAPET 8.CONT 2x PT PLATE W/ 1/2" Ø ANCHOR BOLTS AT 32" O.C. W/ 4" MIN. EMBEDMENT 5 6 7 1 2 3 4 1/4 3 31/4 3/16 3-12 8 203 STEEL JOIST AT EXISTING WALL MS-SC216 NO SCALE 204 STEEL JOIST ATEXISTING WALL MS-SC216 NO SCALE KEYNOTES: 1.CONT L3x3x1/4 W/ (1) 1/2" Ø EPOXY BOLT AND 5" MIN. EMBEDMENT AT 24" O.C. USING HILTY-HY 270 EPOXY SYSTEM. (THIS APPLIES FOR A SOLID-GROUTED WALL, SEE KEYNOTE 6 IF EXISTING WALL IS NOT GROUTED) 2.BOUNDARY ATTACHMENT, SEE PLAN 3.STEEL DECK, SEE PLAN 4.STEEL JOIST, SEE PLAN 5.EXISTING WALL 6.AT EXISTING WALL, IF MASONRY IS NOT GROUTED AT LOCATION WHERE ANCHOR BOLT IS TO BE INSTALLED, BOLT SPACING MUST BE REDUCED TO 8" O.C. USE HILTI-HY 270 SCREEN TUBE EPOXY SYSTEM W/ 2-1/2" OF EMBEDMENT KEYNOTES: 1.CONT L6x4x3/8 (LLV) W/ (1) 1/2" Ø EPOXY BOLT AND 5" MIN. EMBEDMENT AT 24" O.C. USING HILTI-HY 270 EPOXY SYSTEM (THIS APPLIES FOR A SOLID-GROUTED WALL, SEE KEYNOTE 7 IF EXISTING WALL IS NOT GROUTED) 2.BOUNDARY ATTACHMENT, SEE PLAN 3.STEEL DECK, SEE PLAN 4.STEEL JOIST, SEE PLAN 5.EXISTING WALL 6.L212,212, 14 BETWEEN EACH JOIST 7.AT EXISTING WALL, IF MASONRY IS NOT GROUTED AT LOCATION WHERE ANCHOR BOLT IS TO BE INSTALLED, BOLT SPACING MUST BE REDUCED TO 8" O.C. USE HILTY-HY270 SCREEN TUBE EPOXY SYSTEM W/ 2-1/2" OF EMBEDMENT 5 1 2 3 4 5 1 2 3 4 1/4 3 31/4 3/16 3-12 6 9 112" 8 112" 112" 7 112" 6 PRO F E S S I O N A L ENG I N E E R S T ATE O F I D A H O A 6/ 2 / 2 1 14 1 3 4 D VID B . P O R T E R L I C E N SED STRUCTURAL ENGINEERING JR W & A S S O C I A T E S , P L L C . D R A W I N G S A N D D E S I G N S A R E P R O T E C T E D B Y C O P Y R I G H T A N D T H E A R C H I T E C T R E T A I N S T O T A L O W N E R S H I P A N D C O N T R O L . A N Y U N A U T H O R I Z E D U S E O F D R A W I N G S , D E S I G N S O R I D E A S W I T H O U T W R I T T E N C O N S E N T O F T H E A R C H I T E C T A R E P R O H I B I T E D PROJECT MANAGER:CAD OPERATOR:JOB NO.: Structural Engineering This drawing is the property of FROST Structural Engineering, Inc. Legally, the drawing can NOT be copied in whole or in pieces. It is only to be used for the project and site specifically identified hereon and is not to be used on any other project. Contractor shall carefully review all dimensions, details, and conditions and report at once any error, inconsistency or omission discovered before construction. The contractor assumes full liability for deviations from the intent of these plans. fax: 208.227.8405 1020 E. Lincoln Road Idaho Falls, ID 83401 phone: 208.227.8404 contact@frost-structural.com DMEKBBIF21-094 Engineered Systems Associates MECHANICAL ENGINEERING Engineered Systems Assoc. 1335 East Center Street Pocetello, Idaho 83204 Tel:(208) 233-0501 Fax:(208) 233-0529 ELECTRICAL ENGINEERING Payne Engineering INC. 1832 East Center Street Pocetello, Idaho 83201 Tel:(208) 232-4439 Fax:(208) 232-1435 Consultants: 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 FA X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: Checked By: Plot Date: Drawing Number: File: Revisions: OF 831 MAY 2021 SR DCS CO S T A V I D A RE X B U R G , ID A H O AD D I T I O N FLOOR PLAN - MECHANICAL NorthSCALE: 1/4" = 1'-0" PLAN NOTES: M1.1 ME C H A N I C A L F L O O R P L A N ELECTRONIC THERMOSTAT EQUIPMENT SYMBOLFC 1 T INSULATED FLEXIBLE DUCT RECTANGULAR SUPPLY AND RETURN AIR DUCT TAKE-OFF TURNING VANES DUCT TRANSITION MECHANICAL LEGEND DESCRIPTIONSYMBOL CEILING RETURN AIR GRILLE PROVIDE TRANSITION FROM ROOFTOP UNIT SUPPLY AND RETURN AIR DUCTWORK INLET & OUTLET TO 16x14 SUPPLY AND RETURN AIR DUCTWORK. 1 1 KH 1 EF (ON ROOF) 10"Ø EA DUCT TRT-1 1 RT D-1 400 D-1 400 D-1 400 R-1(2) REMARKSWBMBH COOLING EATLATEATCONN GAS BTU IN HEATING BTU OUTWEIGHTMCACHARH.P. BLOWER ROOF TOP HEATING & AIR CONDITIONING UNIT SCHEDULE SPESYM.CFM REQUIRED OUTSIDE AIR 1 RT 1,200 62°F36.0 80°F LENNOX LGH036H4B WITH FACTORY ROOF CURB AND ECONOMIZER104°F65°F3/4"550#28.03/40.7"450 208/60/1 81,000 65,000 CEILING SUPPLY DIFFUSER ROOF MOUNTED UP-BLAST EXHAUST FAN A-THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONNECTIONS ON THE JOB SITE. ALL WORK SHALL BE EXECUTED FROM MEASUREMENTS TAKEN AT THE SITE. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE TO INSURE PROPER CODE CLEARANCES FOR ELECTRICAL AND MECHANICAL ACCESS WHEN INSTALLING ANY EQUIPMENT SUPPLIED BY THE MECHANICAL CONTRACTOR. IT IS CRITICAL THAT THIS CONTRACTOR COORDINATE EQUIPMENT LOCATIONS WITH PIPING, DUCTWORK, ELECTRICAL CONDUIT AND BUILDING STRUCTURE TO INSURE CODE COMPLIANCE. CEILING DIFFUSERS ARE SHOWN IN APPROXIMATE LOCATIONS. REFER TO LIGHTING PLANS AND REFLECTED CEILING PLAN FOR EXACT LOCATIONS. DUCT DIMENSIONS CALLED OUT ON DRAWINGS ARE INSIDE FREE AREA DIMENSIONS. ACOUSTICAL DUCT LINER ARE TO BE ADDED TO OVERALL MEASUREMENTS. ALL DUCTWORK AND PIPING WHICH PASSES THRU FIRE RATED WALLS TO BE FIRE STOPPED WITH APPROVED FOAM OR SEALANT. REFER TO SPECIFICATIONS FOR APPROVED MANUFACTURES. F- E- D- C- B- GENERAL NOTES: R-1 D-1 CFM REMARKSFIRE DAMPERFINISHCONSTR.DAMPER BALANCINGCFM RANGESIZE THROW GRILLE AND REGISTER SCHEDULE PATTERNTYPESYM. CEILING NA NANASTEEL450-70016x16 PRICE MODEL 535 STEEL NA NACEILING12x12 PRICE MODEL SMD IN 24x24 LAY-IN MODULE300-450 WHITE WHITE IN 24x24 LAY-IN MODULE DRIVE THRU 101 PREP 102 PREP 103 (E) COSTA VIDA RESTAURANT 1 KH 10"Ø E A SCALE: 1/4" = 1'-0" KITCHEN HOOD SECTION M-1 A M-1 A 80 " TORTILLA GRIDDLE EXHAUST FAN SCHEDULE REMARKSR.P.M.WATTS CHAR.CONTROLC.F.M.TYPE S.P.E. EF 1 SYM. ROOF MOUNTED 600 0.5 1/3 H.P.120/60/1 1316 CAPTIVEAIRE MODEL DU33HFA UPBLAST FAN WITH FACTORY ROOF CURB TO MATCH ROOF SLOPE AND BACKDRAFT DAMPER.HOOD INTELOCK W/ LENGTH KH SYM. 1 WIDTH 48" KITCHEN HOOD UNIT SCHEDULE HEIGHT 24" TYPE VAPOR HOOD EXH CFM 600 FAN SYM 1 EF DUCT EXHAUSTMAKE-UP CFM 450 10"Ø WEIGHT 163 LBS48"TYPE 2 REMARKS: CAPTIVEAIRE MODEL 4824VHB S.S. HOOD WITH 24" HIGH FIELD WRAPPER ON FRONT AND LEFT. MOUNT HOOD AT 80" A.F.F TO BOTTOM OF HOOD. SCALE: 1/4" = 1'-0" KITCHEN HOOD DETAIL 4' - 0 " 4'-0" 10"Ø EXHAUST RISER 24" HIGH TEMP LIGHT FIXTURE PROVIDE STAINLESS STEEL EXTENSION FROM HOOD TO CEILING. 10"Ø EXHAUST RISER 40 " M I N 5'-0" MIN.PARAPET MOUNT FAN ON 20" HIGH ROOF CURB (E ) C O S T A V I D A R E S T A U R A N T 16 x 1 4 R A HD 10 " Ø S A HD HD FROM RT-1 16 x 1 4 S A 10"Ø SA 10"Ø SA 10"Ø SA 12"Ø RA 12"Ø RA 1 1 Engineered Systems Associates MECHANICAL ENGINEERING Engineered Systems Assoc. 1335 East Center Street Pocetello, Idaho 83204 Tel:(208) 233-0501 Fax:(208) 233-0529 ELECTRICAL ENGINEERING Payne Engineering INC. 1832 East Center Street Pocetello, Idaho 83201 Tel:(208) 232-4439 Fax:(208) 232-1435 Consultants: 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 FA X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: Checked By: Plot Date: Drawing Number: File: Revisions: OF 831 MAY 2021 SR DCS CO S T A V I D A RE X B U R G , ID A H O AD D I T I O N M2.0 ME C H A N I C A L D E T A I L S CEILING DIFFUSER DETAIL WITH FLEXIBLE DUCT NO SCALE DUCT SUPPORT 1" ACOUSTICAL DUCT LINER ON INTERIOR OF DUCT. 24" MAX TO FIRST SUPPORT RIGID SPIN- IN FITTING HAND DAMPER HANDLE ROUND RIGID DUCT. WING NUT RECTANGULAR SUPPLY DUCT GLUE FLEX DUCT TO FITTING, CLAMP DOWN WITH STRAP AND SCREW SOLID TO RIGID FITTING ATTACH TO RIGID DUCT WITH DRAW BAND OPPOSED BLADE DAMPER WHERE SPECIFIED LAY-IN DIFFUSER LAY-IN CEILING ROUND TO SQUARE TRANSITION GLUE FLEX DUCT TO ADAPTER & CLAMP DOWN WITH STRAP. ROUND FLEXIBLE SUPPLY DUCT TO CEILING DIFFUSER 8'-0" MAX. LENGTH 24" MAX TO FIRST SUPPORT DUCT SUPPORT EXTERNAL DUCT INSULATION ON ALL ROUND RIGID DUCT- WORK AND FITTINGS. REINFORCING DUCT CONSTRUCTION AND HANGER DETAIL MENDED GAGE 24 26 DRIVE RECOM- SLIP NO SCALE 19 - 30 13 - 18 UP THRU 12 LONGEST INCHES SIDE, DIMENSION NONE REQUIRED26 NONE REQUIRED 1"x1"x1/8" @ 60 IN24 24 (ALL FOUR SIDES) OF GAGE METAL SHEET BETWEEN INTERMEDIATE REINFORCING JOINTS &/OR TRANSVERSE ANGLE SIZE SPACING LONGITUDINAL AND MAXIMUM 2"2" 26 MAX. 12" OC 24 24- S SLIP RECOM- MENDED GAGE HEMMED 1" TRANSVERSE REINFORCING (1) MINIMUM AT JOINTS (1) TRANSVERSE REINFORCING SIZE IS DETERMINED BY DIMENSION OF SIDE TO WHICH ANGLE IS APPLIED. GRIP NAILS SHALL BE INSTALLED BY GRIPNAIL AIR HAMMER OR BY AUTOMATIC FASTENER EQUIP. METAL FASTENERS - OMARK INSULPINS, DURO DYNE FASTENERS OR GRIPNAILS. STRAPS TO BE TIGHT AGAINST DUCTWORK HANG DUCTS UP TO 30" WIDTH WITH 1" x 18 GAGE STRAPS AT 10'-0" MAXIMUM SPACING. SELF-TAPPING CADMIUM PLATED HEX HEAD SHEET METAL SCREW NO POP RIVETS ALLOWED HANGER STRAPS SHEET METAL DUCT NOT MORE THAN 2" FROM EDGE OF LINER ALL ENDS OF LINER TO BE COATED WITH ADHESIVE. SEE SPECIFICATIONS. 1" THICK DUCT LINER TOP AND BOTTOM SECTION OF LINER SHALL OVERLAP THE SIDES ENDS OF LINER SHALL BE BUTTED FIRMLY TOGETHER LINER TO BE ADHERED TO DUCT W/100% ADHESIVE SEE SPECIFICATIONS. UNIT ROOFTOP ROOF CURB STRIP NAILING ROOF DECK JOISTS COUNTER FLASHING PREPARED SURFACE SINGLE PLY ROOFING ROOFING MATERIAL SINGLE PLY CANT STRIP NEOPRENE WASHERS FASTENER WITH INSULATION RIGID ROOF DECK JOISTS OF HOW TRUSSES ARE RUNNING AS POSSIBLE REGARDLESS UNIT OVER AS MANY TRUSSES WEIGHT OF THE MECHANICAL MANNER AS TO SPREAD THE OVER ROOF JOISTS IN SUCH A POSITION ROOF CURB NOTE: NO SCALE TYPICAL ROOFTOP MOUNTING DETAIL FLEXIBLE DUCT SUPPORT DETAIL NO SCALE 2' - 0 " M A X I M U M FOOT OF SUPPORT SPACING. MAX. SAG 1/2" PER BAND CLAMP 1"x18 GAGE SECURE TO STRUCTURE. ROOF TOP EXHAUST FAN DETAIL NO SCALE SPUN ALUMINUM UP-BLAST ROOF EXHAUSTER ROOFING EXHAUST DUCT UP FROM BELOW, SIZE AS SHOWN ON KITCHEN HOOD DETAILS SECURE & CAULK TO CURB FACTORY HINGED CURB TO MATCH ROOF SLOPE 1 EF Engineered Systems Associates MECHANICAL ENGINEERING Engineered Systems Assoc. 1335 East Center Street Pocetello, Idaho 83204 Tel:(208) 233-0501 Fax:(208) 233-0529 ELECTRICAL ENGINEERING Payne Engineering INC. 1832 East Center Street Pocetello, Idaho 83201 Tel:(208) 232-4439 Fax:(208) 232-1435 Consultants: 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 FA X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: Checked By: Plot Date: Drawing Number: File: Revisions: OF 831 MAY 2021 SR DCS CO S T A V I D A RE X B U R G , ID A H O AD D I T I O N FLOOR PLAN - PLUMBING NorthSCALE: 1/4" = 1'-0" PLAN NOTES: P1.1 PL U M B I N G F L O O R P L A N CONNECT NEW 4" WASTE LINE TO EXISTING 4" OR LARGER SEWER. FIELD VERIFY EXACT LOCATION AND DIRECTION OF FLOW OF EXISTING SEWER MAIN. INSTALL 1/2" BACKFLOW PREVENTOR ON 1/2" CW LINE SERVING (2) ICE MAKERS. RUN DRAIN LINE TO FLOOR SINK BELOW WITH AIR GAP. SEE DETAIL ON SHEET P2.0 CONNECT NEW 3/4" CW AND 1/2" HW LINES TO EXISTING 3/4" HOT AND COLD WATER LINES AT WATER HEATER. FIELD VERIFY EXACT LOCATION OF EXISTING PIPING. RELOCATE EXISTING 4" PVC INTAKE AND CONNECT TO EXISTING INTAKE ON ROOF NEXT TO EXISTING WATER HEATER FLUE. FIELD VERIFY EXISTING CONDITIONS. CONNECT NEW 3/4" (2 PSI) GAS LINE TO EXISTING 3/4" (2 PSI) OR LARGER GAS LINE ON ROOF. FIELD VERIFY EXISTING LOCATION OF GAS LINE. INSTALL NEW GAS LINE ON ROOF ON ERICO PIPE PIER SUPPORTS OR APPROVED EQUAL AT 10'-0" ON CENTER. INSTALL 2 PSI TO OZ. GAS REGULATOR ON 3/4" GAS LINE SERVING NEW RTU SIZED FOR ACTUAL BTU LOAD OF UNIT SUPPLIED. CONNECT NEW 3/4" (OZ.) GAS LINE TO UNIT COMPLETE WITH SHUT-OFF VALVE, DIRT LEG AND FLEXIBLE CONNECTION. SEE DETAIL ON SHEET P2.0. DROP 3/4" (2 PSI) GAS LINE DOWN EXPOSED ON INTERIOR SIDE OF WALL TO SERVE GAS FIRED TORTILLA GRIDDLE. INSTALL 2 PSI TO OZ. GAS REGULATOR ON GAS LINE SIZED FOR ACTUAL BTU LOAD OF GRIDDLE SUPPLIED. CONNECT 3/4" (OZ.) GAS LINE TO GRIDDLE COMPLETE WITH SHUT-OFF VALVE, FLEXIBLE CONNECTION AND DIRT LEG. SEE DETAIL ON SHEET P2.0 DROP 3/4" (2 PSI) GAS LINE DOWN THRU ROOF TO CEILING SPACE AND RUN AS SHOWN TO SERVE TORTILLA GRIDDLE. SEAL ROOF PENETRATION WEATHERTIGHT. RELOCATE EXISTING SEWER CLEAN OUT TO GRADE TO NEW LOCATION OUTSIDE OF NEW ADDITION. FIELD VERIFY EXISTING SEWER LOCATION AND MODIFY AS REQUIRED. RUN 3/4" CONDENSATE DRAIN LINE FROM ROOFTOP UNIT TO ROOF AS SHOWN ON DETAIL ON SHEET P2.0 1 1 RT A-THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONNECTIONS ON THE JOB SITE. ALL WORK SHALL BE EXECUTED FROM MEASUREMENTS TAKEN AT THE SITE. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE TO INSURE PROPER CODE CLEARANCES FOR ELECTRICAL AND MECHANICAL ACCESS WHEN INSTALLING ANY EQUIPMENT SUPPLIED BY THE MECHANICAL CONTRACTOR. IT IS CRITICAL THAT THIS CONTRACTOR COORDINATE EQUIPMENT LOCATIONS WITH PIPING, DUCTWORK, ELECTRICAL CONDUIT AND BUILDING STRUCTURE TO INSURE CODE COMPLIANCE. CEILING DIFFUSERS ARE SHOWN IN APPROXIMATE LOCATIONS. REFER TO LIGHTING PLANS AND REFLECTED CEILING PLAN FOR EXACT LOCATIONS. DUCT DIMENSIONS CALLED OUT ON DRAWINGS ARE INSIDE FREE AREA DIMENSIONS. ACOUSTICAL DUCT LINER ARE TO BE ADDED TO OVERALL MEASUREMENTS. ALL DUCTWORK AND PIPING WHICH PASSES THRU FIRE RATED WALLS TO BE FIRE STOPPED WITH APPROVED FOAM OR SEALANT. REFER TO SPECIFICATIONS FOR APPROVED MANUFACTURES. F- E- D- C- B- GENERAL NOTES: DRIVE THRU 101 PREP 102 PREP 103 (E) COSTA VIDA RESTAURANT IB-1 IM-1 HS-1 HW-2 CW-1 FS-1 HW-1 TG-1 IM-2 FS-1 4" VTR G G G BALL TYPE ISOLATION VALVE PIPE RISE PIPE DROP SYMBOL CO WCO COTG VTR V VENT VENT THRU ROOF CLEANOUT WALL CLEANOUT CLEANOUT TO GRADE DESCRIPTION PLUMBING LEGEND SOIL OR WASTE PIPING VENT LINE PIPING DOMESTIC HOT WATER PIPING DOMESTIC SOFT COLD WATER DOMESTIC HOT WATER RECIRC. RDO RDL ROOF DRAIN PIPING ROOF OVERFLOW DRAIN PIPING NATURAL GAS PIPINGG GREASE WASTE PIPINGGW FLOOR SINK - ZURN Z-1900-KC WITH WHITE ENAMEL FINISH, DOME STRAINER AND 4" DEEP SEAL P-TRAP. PROVIDE 1/2 GRATE OVER SINK. ------4"2"FS-1 ADA WALL MOUNTED HAND WASH SINK K.E.C #16- S.S. HAND WASH SINK & FAUCET SUPPLIED BY K.E.C. PLUMBING CONTRACTOR TO INSTALL SINK & FAUCET WITH 1/2" STOPS AND 1-1/2" P-TRAP. PROVIDE INSULATING JACKET ON WATER AND WASTE PIPE. 1-1/2"1/2"1/2"1-1/2"HS-1 ROOF DRAIN - JAY R SMITH MODEL 1010 SIZE 3" WITH UNDERDECK CLAMP AND FLASHING. ------3"--- ROOF OVERFLOW DRAIN - JAY R SMITH MODEL 1080 SIZE 3" WITH 2" HIGH WATER DAM, UNDERDECK CLAMP AND FLASHING. ------3"--- RD-1 OD-1 COLD FIXTURE SCHEDULE DESCRIPTIONSYM.HOT WASTE VENT DS-1 ROOF DRAIN DOWN SPOUT - JAY R SMITH MODEL 1770 SIZE 3" WITH ROUGH BRONZE FINISH AND 3" DRAIN LINE CONNECTION. ------3"--- TG-1 GAS FIRED TORTILLA GRIDDLE K.E.C. #37- SUPPLIED BY K.E.C. PLUMBING CONTRACTOR TO CONNECT 3/4" GAS LINE COMPLETE WITH SHUT-OFF VALVE, FLEXIBLE CONNECTION AND DIRT LEG. SEE FLOOR PLANS. 50,000 BTU CAPACITY ------------ IM-1 ICE MAKER WITHOUT ICE BIN K.E.C #6 - SUPPLIED BY K.E.C. PLUMBING CONTRACTOR TO CONNECT 3/8" CW LINE TO UNIT AND 3/4" DRAIN LINE FROM UNIT TO FLOOR SINK LOCATED UNDER CABINET AND TERMINATE WITH DOWNTURNED 90° ELBOW AND AIRGAP. ---3/8"3/4"--- IB-1 ICE BIN K.E.C #7 - SUPPLIED BY K.E.C. PLUMBING CONTRACTOR TO CONNECT 1" DRAIN LINE FROM UNIT TO FLOOR SINK LOCATED UNDER CABINET AND TERMINATE WITH DOWNTURNED 90° ELBOW AND AIRGAP. ------1"--- IM-2 DRIVE THRU ICE MAKER K.E.C #41.2 - SUPPLIED BY K.E.C. PLUMBING CONTRACTOR TO CONNECT 3/8" CW LINE TO UNIT AND 1" DRAIN LINE FROM UNIT TO FLOOR SINK LOCATED UNDER CABINET AND TERMINATE WITH DOWNTURNED 90° ELBOW AND AIRGAP. ---3/8"1"--- CW-1 COLD FOOD WELL K.E.C #52 - SUPPLIED BY K.E.C. PLUMBING CONTRACTOR TO CONNECT 1" DRAIN LINE FROM UNIT TO FLOOR SINK LOCATED UNDER CABINET AND TERMINATE WITH DOWNTURNED 90° ELBOW AND AIRGAP. ------1"--- HW-1 HOT FOOD WELL K.E.C #51 - SUPPLIED BY K.E.C. PLUMBING CONTRACTOR TO CONNECT 1" DRAIN LINE FROM EACH COMPARTMENT OF UNIT TO FLOOR SINK LOCATED UNDER CABINET AND TERMINATE WITH DOWNTURNED 90° ELBOW AND AIRGAP. ------1"--- TL-1 HW-2 HOT FOOD WELL K.E.C #52 - SUPPLIED BY K.E.C. PLUMBING CONTRACTOR TO CONNECT 1" DRAIN LINE FROM UNIT TO FLOOR SINK LOCATED UNDER CABINET AND TERMINATE WITH DOWNTURNED 90° ELBOW AND AIRGAP. ------1"--- TL-1 TO GO LINE FAUCET K.E.C #49 - SUPPLIED BY K.E.C. PLUMBING CONTRACTOR TO CONNECT 1/2" HW LINE COMPLETE WITH BALL TYPE SHUT-OFF VALVE AND S.S. BRAIDED FLEXIBLE CONNECTION. 1/2"--------- 4" COTG INV. ELEV. 97'-0" 1 (E) SEWER MAIN 2" V. & WCO 2" V. & WCO 2" WCO (E) WATER HEATER (E) GAS PIPING ON ROOF 3/4" (2 PSI) ABOVE CLG. 3/4" 1/2" PENETRATE WALL & SEAL ALL AROUND 3/4" 1/2" 1/2" 1/2" 2 2 3 3 1/2" 2" 1/2" 1/2" 3/4" 2"4" 2" 2" 4" 4"4" 4" (E) SEWER COTG'S(NEW) SEWER COTG LOCATIONS (ON ROOF) 4 4 (E) C02 TANK & PIPING TO BE RELOCATED BY OTHERS 5 5 6 7 7 8 8 BALL VALVES 1" DRAIN 1" DRAIN G G G G G G 3/4" (2 PSI) ABOVE CLG. 3/4" (2 PSI) ABOVE CLG. 6 RISE OVER PARAPET 3/4" (2 PSI) ON ROOF 4 DS-1 DS-2 (+18" ABOVE GRADE)(HIGH AS POSS.) DS-2 ROOF OVERFLOW DRAIN DOWN SPOUT - JAY R SMITH MODEL 1770 SIZE 3" WITH ROUGH BRONZE FINISH AND 3" DRAIN LINE CONNECTION. ------3"--- OD-1 (ABOVE) RD-1 (ABOVE) 3"3" 9 9 10 10 10 (E) GAS PIPING ON ROOF (E) RISE OVER PARAPET 12 12 ROOF AREA 530 SQ. FT. Engineered Systems Associates MECHANICAL ENGINEERING Engineered Systems Assoc. 1335 East Center Street Pocetello, Idaho 83204 Tel:(208) 233-0501 Fax:(208) 233-0529 ELECTRICAL ENGINEERING Payne Engineering INC. 1832 East Center Street Pocetello, Idaho 83201 Tel:(208) 232-4439 Fax:(208) 232-1435 Consultants: 11 5 2 B O N D A V E N U E - S u i t e A RE X B U R G , I D A H O 8 3 4 4 0 VO I C E ( 2 0 8 ) 3 5 9 - 2 3 0 9 FA X ( 2 0 8 ) 3 5 9 - 2 2 7 1 WW W . J R W A . C O M Job Number: Date: Drawn By: Checked By: Plot Date: Drawing Number: File: Revisions: OF 831 MAY 2021 SR DCS CO S T A V I D A RE X B U R G , ID A H O AD D I T I O N P2.0 PL U M B I N G D E T A I L S CLEAN OUT DETAILS NO SCALE CLEANOUT TO GRADE (COTG) WASTE LINE FINISH GRADE 1'-0" WALL CLEANOUT (WCO) 1/8 C.I. BEND FLOOR LINE WALL BRASS CLEANOUT PLUG WITH COUNTER SUNK HEAD 16" SQUARE CONC PAD TROWEL SMOOTH 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE. CAST IRON WASTE LINE. LENGTH TO SUIT. CHROME WALL COVER AND SCREW MAY EXTEND AS A WASTE OR VENT PLUGGED TEE WITH CLEANOUT BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. 1/8 CAST IRON BEND SWIVEL GAS HOSE CONNECTOR DETAIL NO SCALE (REC . ) 36" M I N 30" M I N (REC . ) 18"M I N (REC . ) VERT I C A L HOR I Z O N T A L WALL BRACKET TYPICAL KITCHEN EQUIPMENT (SEE FLOOR PLANS) SHUT-OFF VALVE SWIVEL QUICK DISCONNECT FITTINGS AND FLEXIBLE HOSE RESTRAINING CABLE BY OTHERS EQUIPMENT REGULATOR BACKFLOW PREVENTER DETAIL NO SCALE IN OUT AIR GAP FUNNEL DRAIN 1" DRAIN LINE TO NEAREST FLOOR DRAIN OR SERVICE SINK WATTS 009 SERIES REDUCED PRESSURE BACKFLOW PREVENTER SIZE TO MATCH LINE SIZE AS SHOWN ON PLANS.TYPICAL TEST COCK SHUT-OFF VALVE SHUT-OFF VALVE UNIONUNION ICE MAKER CW LINE OVERFLOW ROOF DRAIN DETAIL OVERFLOW LINE ROOF DECK NO SCALE RDL UNDERDECK CLAMP ROOF DRAIN 36" SQUARE FLASHING UNDER SINGLE PLY ROOF MEMBRANE RIGID INSULATION 3'-0" DRAIN WATER 2" HIGH DAM NO SCALE CONDENSATE DRAIN (ROOFTOP UNIT) 4"MIN. DEEP SEAL P-TRAP ROOFTOP UNIT DRAIN CONNECTION OPEN TO ATMOSPHERE DRAIN PIPING TO BE THE SAME SIZE AS THE DRAIN PAN CONNECTION SIZE NO LESS THAN 2 TIMES THE PIPE DIAMETER DRAIN ON ROOF 6" V E R T I C A L EQUIPMENT ROOF GROUND JOINT UNION ROOF TOP GAS PRESSURE REGULATOR DETAIL NO SCALE CAPPED PRESSURE TEE GAS PRESSURE REGULATOR 2# TO 1/2# PROVIDE ESCHUCEON PLATE AROUND PIPING FLEXIBLE GAS CONNECTOR. 18" MAX. DRIP LEG SAME SIZE AS PIPE MANUAL MAIN SHUT-OFF VALVE 'PYRAMID' TYPE SUPPORTS P.E. JOB: Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 Consulting Engineers RE X B U R G , CO S T A V I D A ID A H O AD D I T I O N 831 JUNE '21 ELECTRICAL ENGINEERING ORIGINAL SIGNED BY: TODD E. PAYNE DATED ORIGINAL SIGNED: 6-24-2021 ON FILE AT: PAYNE ENGINEERING INC. EL E C T R I C A L D E T A I L S E1.0 SYMBOL SCHEDULE CONT. VOLUME CONTROL. PROVIDE AND INSTALL A 4SQ. WITH SINGLE GANG BOX WITH 3/4" CONDUIT TO ABOVE CEILING FOR VOLUME CONTROL BY OTHERS. 1.ELECTRICAL CONTRACTOR SHALL COORDINATE ALL LAMP TYPES WITH FIXTURE TYPE BEFORE ORDERING. 2.ELECTRICAL CONTRACTOR SHALL REFER TO THE MECHANICAL DRAWINGS FOR EXACT LOCATION OF ALL MECHANICAL EQUIPMENT AND ELECTRICAL CONNECTIONS. 3.ELECTRICAL CONTRACTOR SHALL PROVIDE MINIMUM WORKING CLEARANCE AS PER NEC BEFORE INSTALLING ANY ELECTRICAL PANELS FOR CABINETS. 4.INSTALL ALL LIGHT FIXTURES IN MECHANICAL ROOM AFTER THE MECHANICAL EQUIPMENT IS IN PLACE, ADJUST AS NECESSARY. PROVIDE CHAIN SUSPENSION KITS AS REQUIRED. 5.REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FIXTURE LOCATIONS, CEILING TYPES, ETC. 6.ALL FLUORESCENT FIXTURES SHALL BE SUPPLIED WITH T8 (35K) LAMPS AND ELECTRONIC BALLASTS WITH -20% THD. UNLESS INDICATED OTHERWISE. 7.ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONCRETE PADS AS REQUIRED ON ALL ELECTRICAL EQUIPMENT. 8.CONFIRM EXACT LOCATIONS OF ALL TELEPHONE / DATA OUTLETS WITH OWNER PRIOR TO ROUGH - IN. 9.ELECTRICAL CONTRACTOR SHALL MOUNT SWITCHES AT 48" AND MOUNT CONVENIENCE OUTLETS AT 18" OR AS SHOWN ON PLANS TO MEET HANDICAPPED REQUIREMENTS. 10.LOCATE SWITCHES, OUTLETS, ETC., SHOWN AT ROOM ENTRY DOORWAYS, AS CLOSE TO DOOR FRAME AS POSSIBLE, SO AS NOT TO INTERFERE WITH ROOM CABINETS, ETC. 11.SUPPORT ALL LIGHT FIXTURES INDEPENDENT OF CEILING. 12.ELECTRICAL CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS FOR THIS WORK AND PAY ASSOCIATED FEES. 13.MAINTAIN 24" MIN. CLEARANCE FROM ALL COMMUNICATIONS CABLES AND ELECTRONIC BALLASTS. 14.ALL BATTERY EXIT AND EMERGENCY LIGHTING TO BE CONNECTED TO THE UNSWITCHED LEG OF THE LIGHTING CIRCUIT IN THE AREA AS PER CODE. 15.UNLESS SPECIFICALLY INDICATED OTHERWISE, THE ELECTRICAL CONTRACTOR TO COORDINATE WITH ANY SPECIAL SYSTEMS SUPPLIER /CONTR., EX. DENTAL, MEDICAL, KITCHEN,EQUIPMENT ETC. THE EXACT ROUGH-IN REQUIREMENTS FOR THERE EQUIPMENT. ALSO UNLESS INDICATED OTHERWISE, THE ELECTRICAL CONTR. TO BE RESPONSIBLE FOR FINAL CONNECTIONS TO ALL SPECIAL EQUIPMENT. 16.ALL CONDUIT /RACEWAY /CABLES, TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. IF ANY SURFACE WORK IS NECESSARY, IT SHALL BE APPROVED BY THE ARCHITECT /ENGINEER PRIOR TO DOING ANY WORK. 17.E.C. SHALL VISIT THE SITE PRIOR TO BID AND THOROUGHLY INVESTIGATE THE EXISTING CONDITIONS, AS THEY RELATE TO THE SCOPE OF WORK DESCRIBED. MAKE NECESSARY PROVISIONS IN THE BASE BID TO ADEQUATELY ACCOMMODATE THESE CONDITIONS. 18.JUNCTION BOXES FOR LIGHTING CIRCUITING ARE NOT SHOWN FOR CLARITY. THE E.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING ALL JUNCTION BOXES REQUIRED FOR CIRCUITING OF ALL LIGHT FIXTURES THAT ARE NOT LISTED FOR "THROUGH-BRANCH CIRCUIT WIRING". PROJECT GENERAL NOTES: TO BE MOUNTED AS CLOSE TO TYPICAL DEVICE MOUNTING HEIGHTS DIAGRAM NO SCALE FINISHED FLOOR ARCHITECTURAL PLANS AND DETAILS. DOOR JAMBS AS POSSIBLE. COORDINATE ALL DEVICES WITH 18" - 24" T.V. OUTLET ALL MOUNTING HEIGHTS TYPICAL UNLESS NOTED OTHERWISE. ALL SWITCHES AND THERMOSTATS NOTES: THERMOSTAT OR MECHANICAL SWITCH LIGHT SWITCH CONVENIENCE OUTLET TELEPHONE / DATA OUTLET S T T (OR AS NOTED) 5' - 0'' 4' - 0'' 3' - 6'' 50 60 70 80 S A. COORDINATE OUTLET HEIGHTS WITH ARCHITECTS MILLWORK DWGS. TO INSURE THAT OUTLETS WILL NOT FALL BEHIND CABINETS, BACKSPLASHES, OR INTERFERE WITH WAINSCOTING, ETC. (OR AS NOTED) @ MILLWORK XX" * B. D. *COORDINATE LIGHT SWITCH & OUTLET HEIGHTS WITH ARCHITECTURAL WAINS- COTING AND OR TILE WORK SO AS NOT TO FALL MIDWAY IN THESE FINISHES. * MOUNT VERTICAL OR HORIZONTAL TO MATCH EXISTING DEVICES (TYP) VERIFY WITH MECH. MUD RING ORIENTATION. PE R N E C 3 8 4 - 4 . WA L L PLAN VIEW ELECTRICAL EQUIP. CLEARANCE DETAIL NO SCALE PER NEC 110-26. 36" ELEVATION VIEW 30" WA L L 6' - 6 " A . F . F . 66 " FINISH FLOOR 36" PANEL OR ELECTRICAL EQUIPMENT OR C E I L I N G 6' A . F . F . RECEPTACLE MOUNTING DETAIL NO SCALE TO SUIT WALL RAISED RING CONDUIT(S) ENTRANCE 4'' SQUARE BOX BACK OF COVER W/FELT-TIP MARKER TO BE AS PER SPECIFICATIONS. COVER PLATES - STYLE & COLOR CIRCUIT NUMBER TO BE WRITTEN ON NORMAL POWER COLOR - (SEE SPECS) RECEPTACLE - 20 AMP RATED - SEE SPECIFICATIONS. GROUND CONDUCTOR GREEN INSULATED POWER SUPPLY CONDUIT FOR CEILING OR WALL "J" BOX. RECESSED LIGHT FIXTURE MOUNTING DETAIL NO SCALE CEILING TILE ACOUSTIC ALL SIDES SUPPORT CLIPS TEE BAR GRID INDEPENDENT OF CEILING SYSTEM. (TYPICAL) SUPPORT WIRE BY ELECTRICAL CONTRACTOR IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PREPARE ALL REQUIRED APPLICATIONS AND INFORMATION REQUIRED TO PROVIDE THE OWNER WITH THE MAXIMUM AMOUNT OF REBATE DOLLARS FROM THE LOCAL UTILITY COMPANY. THE ELECTRICAL CONTRACTOR SHALL SUBMIT VERIFICATION OF THE UTILITY COMPANY PRE-APPLICATION APPROVAL PRIOR TO ORDERING ANY MATERIALS. SPECIAL NOTE FOR UTILITY COMPANY LIGHTING REBATES & INCENTIVES: DUPLEX RECEPTACLE WALL MOUNTED FIXTURE CEILING MOUNTED FIXTURE FLUORESCENT FIXTURE ELECTRICAL SYMBOL SCHEDULE BRANCH CIRCUIT - HOME-RUN TO PANEL BRANCH CIRCUIT - IN FLOOR OR UNDERGROUND MECHANICAL EQUIPMENT OR DETAIL SYMBOL DRAWING NOTE (ON THE SHEET WHERE SHOWN) THERMOSTAT W/ 3/4"CONDUIT W/PULL CORD TO MECH. UNIT FAN MOTOR CONNECTION POINT BRANCH CIRCUIT - CONCEALED * SEE MECHANICAL DRAWINGS FOR CONDUIT DESTINATION AND M.C. V.I.F. A.F.F. B.F.G. NL E.C. ABOVE FINISHED FLOOR BELOW FINISHED GRADE VERIFY IN FIELD NIGHT LIGHT (CONNECT TO UNSWITCHED LEG OF LTG CIRCUIT) MECHANICAL CONTRACTOR ELECTRICAL CONTRACTOR MOTOR CONNECTION POINT T EF TELEPHONE / DATA BOARD (GRND AS PER UTIL. CO) TIME CLOCK SWITCHT 1 1 A-1,3 DOUBLE DUPLEX OUTLET (4-PLEX) JUNCTION BOX BRANCH PANELBOARD J EMERGENCY WALL LIGHT WITH 90MIN. BATTERY PHOTOELECTRIC CELL/SWITCH HVAC SYSTEM SENSOR - SEE MECHANICAL E S WALL BOX DIMMER SWITCH. (SWITCH TO BE COMPAT. W/LOAD SERVED) SINGLE POLE SWITCH (SEE SUBSCRIPTS) RECESSED CAN FIXTURE MAIN/DISTRIBUTION PANELBOARD TRAC LIGHT SYSTEM * * PUSHBUTTON (AS INDICATED ON DRAWINGS) ROUGH-IN BOX MUD RING ORIENTATION. RECPT. SUB- SCRIPTS AC=ABOVE COUNTER GFI=GROUND-FAULT IG=ISOLATED GROUND S=SURGE SUPPRESSION TR=UL TAMPER RESISTANT WP=WEATHERPROOF COVER W/GFCI RECEPT. TV= RECPT. FOR TV, SEE ARCH. ELEVATION DWGS FOR MTG. HEIGHT USB=RECEPTACLE W/USB CHARGER CR=CORD REEL (SEE DETAIL) F=FUSED DISCONNECT (FUSE PER EQUIP. NAMEPLATE) DISCONNECT SWITCH (SIZE AND TYPE AS INDICATED) B=ENCLOSED CIRCUIT BREAKER CEILING MOUNTED DUPLEX RECEPTACLE FLOORBOX - POWER ONLY (1-DUPLEX RECEPTACLE) SUCH AS DUAL-LEVEL SWITCHES; IN-BOARD AND OUT-BOARD LAMPS SHALL BE SWITCHED SEPARATELY. (SUBSCRIPT APPLIES TO BOTH SWITCHES) SWITCH SUB- SCRIPTS 3 = 3-WAY 4 = 4-WAY F = EXHAUST FAN TIMER (INTERMATIC MODEL EI400 SERIES) T = THERMAL OVERLOAD SWITCH W/PILOT LIGHT P = 1-POLE SWITCH WITH PILOT LIGHT. (SEE SPECS) M = SWITCH SUPPLIED W/ EQUIPMENT (INSTALLED BY E.C.) WP = WEATHERPROOF CEILING MOUNTED OCCUPANCY SENSOR BLANK = DUAL TECH., LINE VOLTAGE [WATTSTOPPER #DT-355] L = LARGE AREA, ULTRASONIC LOW VOLTAGE [WATTSTOPPER #WT-2205] H = HALLWAY, ULTRASONIC LOW VOLTAGE [WATTSTOPPER #WT-2255] R = RESTROOM, DUAL TECH., LINE VOLTAGE, 2-POLE [SENSOR SWITCH #CMR-PDT-9-2P], (1) RELAY FOR LTG, (1) RELAY FOR EXHAUST FAN (30 MIN. DELAY) D = INTEGRAL DAYLIGHT SENSOR TO AUTOMATICALLY CONTROL FIXTURES IN DAYLIGHT ZONES W = WALL MOUNTED ON/OFF/DIM *PROVIDE LOW VOLTAGE SENSORS WITH POWER/RELAY PACK(S) AS REQUIRED FOR OPERATION. [WATTSTOPPER #BZ-50] EXIT SIGN, WALL OR CEILING MOUNT & DIRECTIONAL ARROWS AS INDICATED ON DRAWINGS. CONNECT TO UNSWITCHED LEG OF NEAREST LIGHTING CIRCUIT. EMERG. FIXTURE WITH EMERG. BATTERY PACK, CONNECTED TO UNSWITCHED LEG OF LIGHTING CIRCUIT. G.C.GENERAL CONTRACTOR N.T.S.NOT TO SCALE V=VFD (PROVIDED BY M.C. CONNECTED AND INSTALLED BY E.C.) COMBINATION STARTER & FUSED DISCONNECT SWITCH; 2-SETS OF NO/NC CONTACTS, CONTROL XFMR, FUSE PER EQUIP. NAMEPLATE CROSS LINES SHOW # OF PHASE/NEUTRAL CONDUCTORS IF MORE THAN TWO. EQUIPMENT/ISOLATED GROUNDING CONDUCTORS ARE NOT SHOWN. PROVIDE 'GREEN' EQUIP. GROUNDING CONDUCTOR FOR ALL CIRCUITS AND ADDITIONAL ISOLATED GROUND WHERE INDICATED. F M LED 0-10V: LEVITON RENOIR II #AWSMG-7D* W/MATCHING WALL PLATE OR EQUAL (* COLOR TO MATCH WIRING DEVICES)S SS S F#E NIGHT LIGHT FIXTURE, CONNECTED FIXTURE TO UNSWITCHED LEG OF LIGHTING CIRCUIT.NL S P SWITCH MOUNTED OCCUPANCY SENSOR, LINE VOLTAGE, W/ COVERPLATE, (COLOR TO MATCH WIRING DEVICES) P = PASSIVE INFRARED,1-POLE [WATTSTOPPER # PW-301] P2 = PASSIVE INFRARED,2-POLE [WATTSTOPPER # PW-302] D = DUAL TECHNOLOGY,1-POLE [WATTSTOPPER # DSW-100] D2 = DUAL TECHNOLOGY,2-POLE [WATTSTOPPER # DSW-200] S W 50A 208V 1Ø WELDER OUTLET BOTTOM HALF OF RECEPTACLE SHALL BE SWITCHED MULTI PURPOSE SCRUBWATER FLOOR BOX. FSR #FL200-4-CSK-S45MM-BKT-FL200-SCU-CBA. WITH DUPLEX RECEPTACLE. E.C. SHALL COORDINATE WITH FLOOR TYPE. HUBBELL CFB2G30/24GCCVRALU/FBNPDUP/FBNPBNK1/HBL8300GRY VOLUME CONTROL. PROVIDE AND INSTALL A 4SQ. WITH 2 GANG BOX WITH 3/4" CONDUIT TO ABOVE CEILING FOR VOLUME CONTROL BY OTHERS. 2V 4 SQUARE BOX WITH SINGLE GANG MUDRING AND 1" CONDUIT TO ABOVE ACCESSIBLE CEILING FOR CABLING BY OWNER. FIRE RATED, MULTI SERVICE POKE THRU, LEGRAND EVOLUTION 8ATC2 WITH 2 DUPLEX RECEPTACLE AND MOUNTING FRAME FOR TWO DATA JACKS. AND ONE HDMI JACK. BOX COVER 8CTC2XX, FINISH BY ARCHITECT. PROVIDE CORE DRILL. INSTALL (1) 1/4" CONDUIT TO AV BOX, (1) 1 1/4" CONDUIT TO ABOVE ACCESSIBLE CEILING AND POWER. LARGE CAPACITY 2 GANG JBOX (HUBBELL HBL260) WITH 2 GANG MUDRING AND VANCO 2 GANG CABLE EXIT BRUSH WALL PLATE (VAN 12082). INSTALL 2" CONDUIT FROM BOX DOWN THRU WALL INTO CEILING SPACE OF FLOOR BELOW FOR AV CABLING. A/V OUTLET: HUBBELL ENCLOSURE# NSAV62M (1) POWERKIT HBL #NSOKPS WITH DUPLEX RECEPTACLE, AND (1) 4-PORT DATA PLATE HBL# NSP14W. OTHER ITEMS BY E.C.: INSTALL 1 1/4"C TO FLOOR BOX WHERE APPLICABLE. CABLE BY OWNER. INSTALL 1 1/4" CONDUIT TO ABOVE ACCESSIBLE CEILING. 4 SQUARE BOX WITH 2 GANG MUDRING AND 1" CONDUIT TO ABOVE ACCESSIBLE CEILING FOR CABLING BY OWNER. 2 EXISTING MULTI METER PACK 4 NEW PANEL-"D" 3"C., 4-#250AL + GROUND 2 2 1 3 1 3 D-25 P.E. JOB: Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 Consulting Engineers RE X B U R G , CO S T A V I D A ID A H O AD D I T I O N 831 JUNE '21 ELECTRICAL ENGINEERING ORIGINAL SIGNED BY: TODD E. PAYNE DATED ORIGINAL SIGNED: 6-24-2021 ON FILE AT: PAYNE ENGINEERING INC. EL E C T R I C A L S I T E P L A N E1.1SCALE: SITE PLAN - ELECTRICAL 1" = 20' - 0"20'0"40'10' N KEY NOTES 1 DRIVE UP ORDER SPEAKER POST AND MENU BOARD. PROVIDE AND INSTALL A 1" CONDUIT WITH PULL CORD FROM POST TO POST TO DRIVE THROUGH WINDOW FOR COMMUNICATION CABLE. FIELD COORDINATE. STUB A 1" CONDUIT OUT FOR VEHICLE SENSOR LOOP. COORDINATE WITH SUPPLYING MANUFACTURER. PROVIDE 120V TO EACH POST. MAKE ALL REQUIRED CONNECTIONS. CONTROL ON/OFF WITH PILOT LIGHT SWITCH ADJACENT TO PANEL. LABEL SWITCH "PILOT LIGHT". E.C. SHALL CONNECT NEW PANEL TO EXISTING 200A 3P BREAKER AND METER SOCKET. FIELD VERIFY EXACT FEEDER ROUTING. 2 3 4 PREP 103 DRIVE THRU 101 PREP 102 3 4 3 F1 F1 F1EM F1EM F1 F1 1 F2 3 2 (TYP) PREP 103 DRIVE THRU 101 PREP 102 D-17 NEW PANEL-"D" WITH FLOOR TO CEILING SKIRTING D-19 F 1 EF 1 RT D-21 D-23 PREP 103 DRIVE THRU 101 PREP 102 6 27.1 48 33 34 36 37 40 41.2 51 55 52 60.1 73 64 P.E. JOB: Pocatello, Idaho 83201 Engineering Inc. 1823 E. Center tel (208) 232-4439 fax (208) 232-1435 Consulting Engineers RE X B U R G , CO S T A V I D A ID A H O AD D I T I O N 831 JUNE '21 ELECTRICAL ENGINEERING ORIGINAL SIGNED BY: TODD E. PAYNE DATED ORIGINAL SIGNED: 6-24-2021 ON FILE AT: PAYNE ENGINEERING INC. EL E C T R I C A L F L O O R P L A N S E2.0 KEY NOTES 1 DISCONNECT AND REMOVE EXISTING EXTERIOR WALL LIGHT IN CONFLICT WITH REMODEL. SPLICE AND EXTEND CIRCUIT. REINSTALL FIXTURE ON NEW EXTERIOR WALL. F1 SHALL BE A 2x4 FLAT PANEL 6000 LUMEN SUCH AS LITHONIA EPANL 2X4 6000LM 80CRI 40K MIN10 ZT MVOLT. PROVIDE EMERGENCY BATTERY E10WCP FOR FIXTURE DESIGNATED "EM". F2 FIXTURE SHALL BE AN EXIT SIGN WITH REMOTE EXTERIOR EGRESS LIGHT SUCH AS LITHONIA LHQM LED G HORO ELA SD QWP LO309. SCALE: MAIN PLAN - LIGHTING 1/8" = 1' - 0"16'8'0"SCALE: MAIN PLAN - POWER 1/8" = 1' - 0"16'8'0" N N SCALE: MAIN PLAN - KITCHEN EQUIPMENT 1/8" = 1' - 0"16'8'0" N 3000 SQ D NQOD 120/208V 3Ø 4W ITEM 34 (1) - 1000 20 1 3000 "D" (2) 20"x39"x5 3/4" 30 2000 1 2000 ITEM 48 (1) 225 18500 154 - 85 10200 145 17500 - DETERMINED TO BE B MAIN BRKR. AMPS LOAD/POLE MAIN LUGS ONLY 19 FEEDER CONDUCTOR SIZE: TOTAL LOAD/PHASE REMARKS: AMPS WATTS 41 29 37 39 35 33 31 27 25 21 23 CLASS LOCATION MAKE/MODEL LOAD NAME AAMPWATTSNO. 9 17 15 11 13 7 5 1 3 E BRKCIRLOAD MAIN SW. OP L 20 S.C. INT CAP/BKR. 40 CONDUIT SIZE 42 30 38 36 34 32 28 26 24 22 AMPS. NO.WATTSECAMP 10 18 16 14 12 8 6 2 4 FEED BOTTOM FEED TOP DIMENSIONS BRK AMPS LOP LOAD CIR SURFACE FLUSH LOAD NAME SUPPLY WITH INTEGRAL SPD. (1) GFCI BREAKER (2) PROVIDE WITH FLOOR TO CEILING FACTORY SKIRTING. ITEM 37 (1) ITEM 40 (1) ITEM 41.2 ITEM 52 (1) ITEM 55 ITEM 60.1 (1) ITEM 73 (1) RECEPTACLES 1000 1000 1000 1000 1000 1000 1000 1000 301 2000 ITEM 48 (1) 302 2000 ITEM 51 --2000 - 202 1000 ITEM 36 (1) --1000 - 202 1000 ITEM 33 (1) --1000 - 502 5000 ITEM 27.1 (1) --5000 - 203 1500 ITEM 6 --1500 - ---1500 KITCHEN EQUIPMENT SCHEDULE CIRCUITAMPSITEM NO.DESCRIPTION ICE MAKER W/O BIN H.P.VOLTS 12.8 208 3 - Ø 3.3 D-38 K.W.FEEDER 1/2"C., 4-#12 + GROUND NOTE 1. REMARKS 6 ICE MAKER COND.-115 1 ---1/2"C., 2-#12 + GROUND POWER FROM ICE HEAD6.2 OVEN, CONVEYOR 41.0 208 1 --D-34 3/4"C., 2-#6 + GROUND NOTE 2.27.1 ELECTRICAL AFF (IN) 72 62 PLANETARY MIXER 11.0 220 1 1.5 -D-30 NOTE 2.33 12 1/2"C., 2-#12 + GROUND DOUGH DIVIDER 8.0 120 1 -1 D-1 NOTE 2.34 12 1/2"C., 2-#12 + GROUND DOUGH PRESS 15.0 220 1 --D-26 NOTE 2.36 42 1/2"C., 2-#12 + GROUND TORTILLA GRIDDLE 10.0 120 1 --D-3 NOTE 2.37 15 1/2"C., 2-#12 + GROUND REFRIGERATOR 7.8 115 1 1/3 0.9 D-5 NOTE 2.40 16 1/2"C., 2-#12 + GROUND ICE MAKER 11.3 115 1 --D-7 -41.2 72 1/2"C., 2-#12 + GROUND PANINI GRILL 18.3 120 1 --D-2, D-4 NOTE 2.48 16 1/2"C., 2-#10+ GROUND HOT WELL 23.2 208 1 -3.6 D-22 -51 16 1/2"C., 2-#10+ GROUND COLD FOOD WELL 3.5 120 1 --D-9 NOTE 2.52 16 1/2"C., 2-#12+ GROUND HOT FOOD WELL 8.3 120 1 -1.0 D-11 -55 16 1/2"C., 2-#12+ GROUND DRINK DISPENSER 8.5 120 1 1/10 1.0 D-13 NOTE 2.60.1 44 1/2"C., 2-#12+ GROUND SODA DISPENSER 5.2 120 1 --D-15 NOTE 2.73 44 1/2"C., 2-#12+ GROUND SCHEDULE NOTES: 1. PROVIDE LOCAL DISCONNECT AND MAKE ALL CONNECTIONS. 2. PROVIDE GFCI BREAKER FOR THIS EQUIPMENT. REFRIGERATOR 2.0 115 1 1/6 0.2 D-6 NOTE 2.64 16 1/2"C., 2-#12+ GROUND 1000 MECHANICAL EQUIPMENT SCHEDULE CIRCUITMCASYMBOL EF 1 EXHAUST FAN DESCRIPTION KITCHEN HOOD H.P.VOLTS -120 1 1/3 Ø -D-37 K.W.FEEDER 1/2"C., 2-#12 + GROUND ON HOOD PROVIDE CONTROL SWITCH REMARKS RT 1 UNIT ROOF-TOP 28.0 208 1 3/4 -D-39 3/4"C., 2-#8 + GROUND AND SERVICE RECEPTACLE PROVIDE LOCAL DISCONNECT 2 3 201 1000 ITEM 64 (1) SPARE ROOF RECEPTACLE DRIVE UP MENU SPARE EF/1 RTU/1 40 2 --- 1000 200 1000 500 3000 3000 1000 1000 1000 1000 1000 1000 3000 1000 2200 1000 2000 1000 5000 1000 5000 4500 2000 4500