Loading...
HomeMy WebLinkAboutINFRASTRUCTURE PLANS 6.21.2021 - 21-00446 - Abi Apartments-Reviewed-Corrections-RequiredAuthor Name Author Email Author Phone No.: Stan Crittenden Stan.Crittenden@rexburg.org 208-372-2314 Tawnya Grover Tawnya.Grover@rexburg.org 208-372-2167 Kyle Baldwin Kyle.Baldwin@rexburg.org 208-372-2164 Joel Gray Joel.Gray@rexburg.org 208-372-2331 Description : Abi Apartments - 4Plex - Bldg 1 Address : RPR4GVR000001B Application Type : Document Filename : INFRASTRUCTURE PLANS 6.21.2021 - 21-00446 - Abi Apartments.pdf Array Comment Author Contact Information: Corrections in the following table need to be applied before a permit can be issued Review Report Revisions Required Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments SD1.1 Callout Stan Crittenden : Fire Open 1 Over 30 units requires a second access point. IFC Appendix D:D107.1 SD1.1 Free text Stan Crittenden : Fire Open 1 Fire Department Notes: - Need to have a fire hydrant within 150 ft. of all FDC. - Fire Access roads need proper signage and curbs painted red. SD1.3 Callout Stan Crittenden : Fire Open 3 hydrant to close to the building. SD1.1 Comment Kyle Baldwin : P&Z Open 1 Please show areas designated as snow storage locations SD1.1 Free text Joel Gray : PW Open 1 Street lights are required on both streets. SD1.1 Callout Joel Gray : PW Open 1 ADA Ramps required. SD1.1 Free text Joel Gray : PW Open 1 What is happening with the ditch? SD1.2 Callout Joel Gray : PW Open 2 Appears to be a ROW disparity on the width. # 21-00446 New Multi-Family Residence Report Date: 07.21.2021 Approval of plans does not constitute approval of variance from code Page 1 of 2 Page Reference Annotation Type Author : Department Status Page Review Comments Applicant Response Comments SD1.2 Free text Joel Gray : PW Open 2 Development agreement needs signed. Water rights transferred to City. SD1.3 Callout Joel Gray : PW Open 3 Must tie in prior to manhole. Typ SD1.3 Callout Joel Gray : PW Open 3 Must have exterior valve on culinary if meter is in building. Typ SD1.3 Callout Joel Gray : PW Open 3 5 dumpsters are required. SD1.3 Callout Joel Gray : PW Open 3 Curb and gutter required. SD1.3 Free text Joel Gray : PW Open 3 Water line in street must be Class 50 DI pipe. Report Date: 07.21.2021 Approval of plans does not constitute approval of variance from code Page 2 of 2 Powered by TCPDF (www.tcpdf.org) PROJECT LOCATED ON EAST HALF OF LOT 5 GROVER SUBDIVISION; DIVISION NO. 1, 1ST AMENDED PLAT, MADISON COUNTY IDAHO 323.80 ft 22 6 . 4 9 f t 12 . 0 1 f t 6.01 ft Street lights are required on both streets. ADA Ramps required. Over 30 units requires a second access point. IFC Appendix D:D107.1 Fire Department Notes: - Need to have a fire hydrant within 150 ft. of all FDC. - Fire Access roads need proper signage and curbs painted red. What is happening with the ditch? PROJECT LOCATED ON EAST HALF OF LOT 5 GROVER SUBDIVISION; DIVISION NO. 1, 1ST AMENDED PLAT, MADISON COUNTY IDAHO Appears to be a ROW disparity on the width. Development agreement needs signed. Water rights transferred to City. PROJECT LOCATED ON EAST HALF OF LOT 5 GROVER SUBDIVISION; DIVISION NO. 1, 1ST AMENDED PLAT, MADISON COUNTY IDAHO Must tie in prior to manhole. Typ Must have exterior valve on culinary if meter is in building. Typ 5 dumpsters are required. Curb and gutter required. Water line in street must be Class 50 DI pipe. hydrant to close to the building.