Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT SPECS - 21-00358 - Madison Memorial Hospital Behavioral Health
Features Individually addressable manual fire alarm stations with: Power and data supplied via IDNet or MAPNET II addressable communications using a single wire pair Operation that complies with ADA requirements Visible LED indicator that flashes during communications and is on steady when the station has been activated The NO GRIP Single Action Station and Retrofit Kit are available with a more easily operated pull lever for applications where anticipated users may find the standard station lever difficult to activate Pull lever that protrudes when alarmed Break-rod supplied (use is optional) Models are available with single or double action (breakglass or push) operation UL listed to Standard 38 Compatible with the following Simplex® control panels: Model Series 4007ES, 4008, 4010, 4010ES, 4100ES, 4100U, 4020, 4100, and 4120 fire alarm control panels equipped with either IDNet or MAPNET II communications Model Series 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications Compact construction: Electronics module enclosure minimizes dust infiltration Allows mounting in standard electrical boxes Screw terminals for wiring connections Tamper resistant reset key lock (keyed same as Simplex fire alarm cabinets) Multiple mounting options: Surface or semi-flush with standard boxes or matching Simplex boxes Flush mount adapter kit Adapters are available for retrofitting to commonly available existing boxes Description The Simplex addressable manual station combines the familiar Simplex manual station housing with a compact communication module that is easily installed to satisfy demanding applications. Its integral individual addressable module (IAM) constantly monitors status and communicates changes to the connected control panel via IDNet or MAPNET II communications wiring. * Refer to page 2 for specific model listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7150-0026:224 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4099-9004 Single action 4099-9021 NO GRIP Single action 4099-9805 NO GRIP Retrofit kit ALARMFIRE PULL DOWN PUSH ALARMFIRE KEY OPERATED ONLY ALARMFIRE KEY OPERATED ONLY 4099-9005 Breakglass 4099-9006 Push With 2099-9828 Institutional Cover kit Operation Activation of the 4099-9004 single action manual station requires a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break-rod (visible below the pull lever, use is optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication. Single Action NO GRIP Station 4099-9021. For applications such as California Building Code, Title 24, which requires “Controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist” the model 4099-9021 station provides a more easily operated pull lever compared to standard stations. Retrofit of existing stations is available using the 4099-9805 Retrofit kit. Double Action Stations (Breakglass) require the operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station. Double Action Stations (Push Type) require that a spring loaded interference plate (marked PUSH) be pushed back to access the pull lever of the single action station. Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. (If the break- rod is used, it must be replaced.) Station testing is performed by physical activation of the pull lever. Electrical testing can be also performed by unlocking the station housing to activate the alarm switch. Multi-Application Peripherals UL, ULC, CSFM Listed; IDNet or MAPNET II Communicating Devices FM Approved * Addressable Manual Stations S4099-0005 10/2014 2 S4099-0005 10/2014 Addressable Manual Stations, Red Housing with White Letters and White Pull Lever Model Description Housing Pull Lever Listings 4099-9004 Single Action, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM 4099-9004CB Single Action, Bilingual English and French FEU FIRE TIREZ PULL ULC 4099-9004CF Single Action, French ALARME FEU ABAISSEZ 4099-9004PO Single Action, Portuguese FOGO ALARME PUXE UL, FM 4099-9004SP Single Action, Spanish ALARMA FUEGO JALE 4099-9005 Double Action, Breakglass operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM 4099-9005PO Double Action, Breakglass operation, Portuguese FOGO ALARME PUXE UL, FM 4099-9005SP Double Action, Breakglass operation, Spanish ALARMA FUEGO JALE 4099-9006 Double Action, Push operation, English FIRE ALARM PUSH PULL DOWN UL, ULC, FM, CSFM 4099-9006PO Double Action, Push operation, Portuguese FOGO ALARME EMPURRE PUXE UL, FM 4099-9006SP Double Action, Push operation, Spanish ALARMA FUEGO EMPUJE JALE 4099-9021 Single Action NO GRIP operation, English FIRE ALARM PULL DOWN UL, ULC, FM, CSFM Accessories (refer to pages 3 and 4 for details) Model Description Model Description 2975-9022 Cast aluminum surface mount box, red 2099-9803 Replacement breakglass 2975-9178 Surface mount steel box, red 2099-9804 Replacement break-rod 2099-9813 Semi-flush trim plate for double gang switch box, red 2099-9828 Institutional cover kit for field installation on 4099-9004; Note: Covers LED indicator 2099-9819 Flush mount adapter kit, black 2099-9814 Surface trim plate for Wiremold box V5744-2, red 2099-9820 Flush mount adapter kit, beige 4099-9805 Retrofit Kit for field conversion of a single action station to a NO GRIP station; refer to Installation Instructions 579-1007 for details Power and Communications IDNet or MAPNET II communications, 1 address per station Address Means DIP switch, 8 position Wire Connections Screw terminal for in/out wiring, for 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2) UL Listed Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan polycarbonate or equal Pull Lever Color White with red raised lettering Housing Dimensions 5” H x 3 ¾” W x 1” D (127 mm x 95 mm x 25 mm) Single gang cover plate, 3/4" (19 mm) extension, RACO #773 or equal (supplied by others) Station side view Wall surface Single gang box outline 4" Square box with cover plate Semi-Flush Mount Side View Single Gang Box Mount Single gang box, 2 1/2" deep (64 mm), RACO #500 or equal (supplied by others) Mount flush or with 1/16" (2 mm) maximum extension DO NOT RECESS ALARMFIRE PULL DOWN LED Indicator 4" Square Box Mount 4" (102 mm) square box, 2 1/8" (54 mm) minimum depth, RACO #231 or equal (supplied by others) Addressable Manual Station Semi-Flush Mounting Specifications (refer to Installation Instructions 579-1135 for additional information) Addressable Manual Station Product Selection Preferred Mounting. For surface mounting of these addressable manual stations, the preferred electrical boxes are shown in the illustration to the right. Additional Mounting Reference. Refer to page 4 for Wiremold box mounting compatibility. 3 S4099-0005 10/2014 Application Reference Refer to NFPA 72, the National Fire Alarm and Signaling Code, and all applicable local codes for complete requirements for manual stations. The following summarizes the basic requirements. 1. Stations shall be located in the normal path of exit and distributed in the protected area such that they are unobstructed and readily accessible. 2. Mounting shall be with the operable part not less than 42 in (1.07 m) and not more than 48 in (1.22 m) above floor level. 3. At least one station shall be provided on each floor. Additional stations shall be provided to obtain a travel distance not more than 200 ft (61 m) to the nearest station from any point in the building. 4. When manual station coverage appears limited in any way, additional stations should be installed. 2975-9178 Box 5-3/16" H x 4" W x 2-3/16" D (132 mm x 102 mm x 56 mm) (ordered separately) Knockouts located top and bottom 2975-9022 Cast Box 5" H x 3-7/8" W x 2-3/16" D (127 mm x 98 mm x 56 mm) (ordered separately) Access for 3/4" threaded conduit located top and bottom5" (127 mm) FIR E ALARMFIRE PULL DOWN 4099 Series Addressable Manual Station 1" (25.4 mm) 3-3/4" (95 mm) Station cover hinges open for installation access Simplex 2975-9178 box (shown for reference) Address setting under resealable label (accessible with cover open) Switch wiring (prewired) Field wiring (shown for reference) 1-1/4" (32 mm) 2-5/8" (67 mm) Addressable Manual Stations Surface Mounting Surface Mount Side View with Internal Detail For retrofit and new installations, additional compatible mounting boxes and the required adapter plates are shown in the illustration to the right. TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). Lexan is a trademark of the General Electric Co. Wiremold is a trademark of the Wiremold Company. 8" (203 mm) 6" (152 mm) 4-3/4" (121 mm) 6-3/4" (171 mm) Front View Flush mount adapter kit 2099-9819, Black 2099-9820, Beige Wall surface 4-11/16" (119 mm) square box, 2-1/8" (54 mm) minimum depth (by others) Side View Box must be recessed into wall 1" to 1-1/8" (25.4 mm to 29 mm) Hole cutout must be a minimum of 6" H by 5" W (152 mm by 127 mm) 2099-9814 Surface trim for Wiremold box 5-1/8" H x 5" W (130 mm x 127 mm) Addressable station Two gang switch box, each 3" H x 2" W x 2-3/4" D (76 mm x 51 mm x 70 mm) (supplied by others) 2099-9813 Semi-flush trim for 2 gang switch box, 6" H x 4-1/2" W (152 mm x 114 mm) Wiremold receptacle box model V5744-2 (supplied by others) Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S4099-0005 10/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Addressable Manual Station, Additional Mounting Information Addressable Manual Station, Flush Mounting Information Features TrueAlarm analog sensing provides: Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications For use with the following Simplex® products: 4100ES, 4100U, 4010ES, and 4010 Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details) 4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control panel provides: Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide: Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3) Heat sensors provide: Fixed temperature sensing Rate-of-rise temperature sensing Utility temperature sensing Listed to UL 521 and ULC-S530 General features: Listed to UL 268 and ULC-S529 Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted Designed for EMI compatibility Magnetic test feature is provided Optional accessories include remote LED alarm indicator and output relays Additional base reference: For isolator bases, refer to data sheet S4098-0025 For sounder bases, refer to data sheet S4098-0028 For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. Accepted for use – City of New York Department of Buildings – MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor’s present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor’s average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base’s LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base’s LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors – Photoelectric MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories S4098-0019-16 10/2013 Sensor Base Features Base mounted address selection: Address remains with its programmed location Accessible from front (DIP switch under sensor) General features: Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design mounts on standard outlet box Magnetically operated functional test Sensor Bases 4098-9792, Standard sensor base 4098-9789, Sensor base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (unsupervised) 4098-9791, Sensor base with supervised relay driver output (not compatible with 2120 CDT): Relay operation is programmable and can be manually operated from control panel Use with remote mount 2098-9737 relay Also includes wired connections for remote LED alarm indicator or 4098-9822 relay Sensor Base Options 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4” square electrical box and for surface mounting to 4” octagonal box Can be used for cosmetic retrofitting to existing 6-3/8” diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box (shown in illustration to right) Description TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor’s output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. Mounting Reference Electrical Box Requirements: (boxes are by others) Without relay: 4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep With relay : 4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring TrueAlarm Bases 4098-9789, -9791, & -9792 4-7/8" (124 mm) 15/16" (24 mm) 6-3/8" (162 mm) 1/4" (6.4 mm) 4098-9832 Adapter Plate, required for mounting to surface mounted boxes and 4" square flush box Surface mount reference 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess 2098-9737 Relay (mounts in base electrical box or remotely) 4098-9822 Relay (mounts in base electrical box) Relay Size: 2-1/2" X 1-1/2" X 1" (3.75 cubic inches) (64 mm X 38 mm X 25.4 mm) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. 1-1/2" (38 mm) minimum box depth 2 S4098-0019-16 10/2013 TrueAlarm Sensor Bases and Accessories ALARM TrueAlarm Sensors Features Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Rated spacing distance between sensors: Fixed Temp. Setting UL & ULC Spacing FM Spacing, Either Fixed Temperature Setting 135° F (57.2° C) 60 ft x 60 ft (18.3 m) 20 ft x 20 ft (6.1 m) for fixed temperature only; RTI = Quick 50 ft x 50 ft (15.2 m) for fixed temperature with either rate-of-rise selection; RTI = Ultra Fast 155° F (68° C) 40 ft x 40 ft (12.2 m) Smoke Sensors: Photoelectric technology sensing 360° smoke entry for optimum response Built-in insect screens 4098-9714 Photoelectric Sensor TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, and 3.7%. Sensitivity is selected and monitored at the fire alarm control panel.* The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 2-1/8" (54 mm) LED status indicator 4-7/8" (124 mm) 4098-9714 Photoelectric Sensor with Base 4098-9733 Heat Sensor TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° C). In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° C). This feature can provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. 2-3/8" (60 mm) LED status indicator 4-7/8" (124 mm) 4098-9733 Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. Application Reference Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0019-16 10/2013 TrueAlarm Sensor Bases (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model Description Compatibility Mounting Requirements 4098-9792 Standard Sensor Base, no options Sensors 4098-9714 and 4098-9733 4” octagonal or 4” square box, 1-1/2” min. depth; or single gang box, 2” min. depth 4098-9789 Sensor Base with connections for Remote LED Alarm Indicator or Unsupervised Relay Sensors 4098-9714 and 4098-9733 4” octagonal or 4” square box Note: Box depth requirements depend on total wire count and wire size, refer to accessories list below for reference. ** NOTE: 4098-9791 is NOT compatible with the 2120 CDT 2098-9808 remote LED alarm indicator or 4098-9822 relay 4098-9791** Sensor Base with connections for Supervised Remote Relay and connections for Remote Alarm Indicator or Unsupervised Relay Sensors 4098-9714 and 4098-9733 2098-9737 remote relay (supervised) 2098-9808 remote alarm indicator or 4098-9822 relay (unsupervised) TrueAlarm Sensors Model Description Compatibility Mounting Requirements 4098-9714 Photoelectric Smoke Sensor Bases 4098-9792, 4098-9789, and 4098-9791 Refer to base requirements 4098-9733 Heat Sensor TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements 2098-9737 Supervised Relay, mounts remote or in base electrical box For use with 4098-9791 base Remote Mounting requires 4” octagonal or 4” square box, 1-1/2” minimum depth Base Mounting requires 4” octagonal box, 2-1/8” deep with 1-1/2” extension ring 2098-9808 Remote Red LED Alarm Indicator on single gang stainless steel plate Bases 4098-9789 and 4098-9791 Single gang box, 1-1/2” minimum depth 4098-9822 Relay, tracks base LED status (unsupervised, mounts only in base electrical box) 4” octagonal box, 2-1/8” deep with 1-1/2” extension ring 4098-9832 Adapter Plate Bases 4098-9792, -9789, & -9791 Required for surface or semi-flush mounted 4” square box and for surface mounted 4” octagonal box TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). Tyco Fire Protection Products • Westminster, MA • 01441-0001 • USA S4098-0019-16 10/2013 www.simplexgrinnell.com © 2013 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. General Operating Specifications Communications and Sensor Supervisory Power MAPNET II or IDNet, auto-select, 24-40 VDC w/data, 400 A typical, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Temperature Range 32° to 100° F (0° to 38° C) Operating Temperature Range with 4098 -9733 32° to 122° F (0° to 50° C) with 4098-9714 15° to 122° F (-9° to 50° C) Storage Temperature Range 0° to 140° F (-18° to 60° C) Humidity Range 10 to 95% RH Smoke Sensor Ambient Ratings 4098-9714, Photoelectric Sensor Air velocity = 0-4000 ft/min (0-1220 m/min) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 A, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789 and 4098-9791 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TrueAlarm Analog Sensing Product Selection Chart Specifications Description The Wheelock patented RSS Strobe appliances and RSSP Strobe Plates by Eaton have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options include the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock’s synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4” square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65” of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4” backboxes or for surface mount use with the Wheelock SBL2 surface backbox. Wheelock RSS and RSSP Strobes and Strobe Plates Technical Data TD450040EN Effective July 2016 Supersedes July 2011 2 Technical Data TD450040EN Effective July 2016 Wheelock RSS and RSSP Strobes and Strobe Plates EATON www.eaton.com Features • Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM),and Chicago (BFP) See approvals by model in Specifications and Ordering information • ADA/NFPA/UFC/ANSI compliant. Meets OSHA 29 Part 1910.16 • Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. • Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd. • Strobes produce 1 flash per second over the regulated voltage range • 12 and 24 VDC models with wide UL “Regulated Voltage” using filtered (DC) or unfiltered VRMS input voltage • Synchronize using the Wheelock sync modules or panels with built-in Wheelock Patented Sync Protocol • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire Note:N All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. WARNING PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.EATON.COM/MASSNOTIFICATION OR CONTACT EATON FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6/G10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 Drawings Figure 1. RSS wall strobe - Front & Side Views General Notes • Strobes are designed to flash at 1 flash per second minimum over their “Regulated Voltage Range.” Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. Product Series Audibles/Speakers for RSSP 3 Technical Data TD450040EN Effective July 2016 Wheelock RSS and RSSP Strobes and Strobe Plates EATON www.eaton.com RSS/RSSP Strobes UL/ULC MAX CURRENT a 24VDC Model Regulated Voltage Range VDC 1575 15cd 30cd 75cd 95cd 110cd 115cd 135cd 177cd 185cd 121575W 16.0-33.0 0.255 24MCW 16.0-33.0 0.060 0.092 0.165 0.220 24MCWH 16.0-33.0 0.300 0.420 24MCC 16.0-33.0 0.065 0.105 0.189 0.249 24MCCH 16.0-33.0 0.300 0.420 Table 2. Specification & Ordering Information Agency Approvals Model Order #Strobe Candela Red White Wall Ceiling Non-Sync MountingOptions b Squareor Round UL MEA CSFM FM BFP RSS-24MCW-FR RSS-24MCW-FW RSS-24MCW-AR RSS-121575W-FR RSS-121575W-FW RSS-24MCC-FW RSS-24MCC-FR RSS-24MCCH-FW RSS-24MCWH-FR RSS-24MCWH-FW 9400 9401 9773 7476 7468 3158 3157 3461 3465 3464 15/30/75/110 15/30/75/110 15/30/75/110 15 (75 on Axis) 15 (75 on Axis) 15/30/75/95 15/30/75/95 115/177 135/185 135/185 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X B,D,E,F,G,H,J,N,O,R,X B,D,E,F,G,H,J,N,O,R,X B,D,E,F,G,H,J,N,O,R,X B,D,E,F,G,H,J,N,O,R,X B,D,E,F,G,H,J,N,O,R,X B,D,E,F,G,H,J,N,O,R,X B,D,E,F,G,H,J,N,O,R,X B,D,E,F,G,H,J,N,O,R,X B,D,E,F,G,H,J,N,O,R,X B,D,E,F,G,H,J,N,O,R,X square square square square square square square square square square X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X RSSWP-2475W-FR RSSWP-2475W-FW RSSP-121575W-FR RSSP-24MCW-FR RSSP-24MCWH-FR 9013 3034 7798 9402 9482 180@ 77F 75@-31F 180@ 77 F 75@-31 F 15 (75 on Axis) 15/30/75/110 135/185 X X X X X X X X X X X X X X X B,D,E,F,G,H,J,NO,R,X B,D,E,F,G,H,J,N,O,R,X D,E,Z D,E,Z B,D,E,F,G,H,J,N,O,R,X square square square square square X X X X X X X X X X X X X X X X X X X X Table 3. Specifications Physical Material Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 UL flammability rating. Weight RSS Strobe: 0.40 lbs (0.181 kg) Lens GE Lexan 943A Dimensions RSS Strobe: 4.75” W x 4.75” H x 2.58”D Operating Temperature Indoor: 33.8°F to 120.2°F (0°C to 49°C) and maximum humidity of 93% Wire Connections #12 through #18 AWG Power & General Operating voltage 25/70 VRMS Strobe Output Rating UL 1971 Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock’s DSM Sync Modules, Power Supplies or SAFEPATH products, using Wheelock patented sync protocol a RMS current ratings are per UL maximum RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. b For information on mounting options, refer to specification sheet TD450028EN. Table 1. Maximum RMS Current Eaton is a registered trademark. All other trademarks are property of their respective owners. Wheelock RSS and RSSP Strobes and Strobe Plates Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 www.eaton.com/massnotification © 2016 Eaton All Rights Reserved Printed in USA Publication No. TD450040EN July 2016 Technical Data TD450040EN Effective July 2016 The visual notification appliances shall be Wheelock RSS Strobe appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing- Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The RSS Strobe shall be of low current design. Where Multi- Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. When synchronization is required, the appliance shall be compatible with Wheelock’s DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any- time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The RSS Strobe appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single gang, double-gang, 4-inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. UL, MEA, CSFM, BFP, FM Note:N Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc., dba Eaton standard terms and conditions. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Architects and Engineers Specifications Description The Wheelock Series CH Chimes and Chime Strobes minimize alarm system power supply requirements and wiring costs with a low current draw and a patented chime mounting plate for fast, easy installation. Each model has a built-in level adjustment feature and an aesthetic two (2) screw grille cover. These unique solid-state chime appliances provide field selectable single-stroke or vibrating operation with Anechoic sound levels adjustable up to 83 dB and tone adjustable from 800 to 1200 Hz. Strobe options for wall mount models include 1575cd or Wheelock patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/110cd or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models are available in Wheelock patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The strobe portion of all Series CH Chime Strobes may be synchronized when used in conjunction with the Wheelock, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. Wheelock’s synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72 and UFC. The Series CH Chime Strobes are UL Listed for indoor, wall or ceiling mount applications under Standard 1971 for Signaling Devices for the Hearing-Impaired and under Standard 464 for Private Mode Audible Signal Appliances. They are available in two attractive package styles for flush mounting to standard electrical boxes or convenient surface mounting. All models include IN/OUT wiring terminations that accept two #12 to #18 AWG wires at each terminal. Inputs are polarized for compatibility with industry standard reverse polarity supervision. Features • Approvals include: UL Standard 1971, UL Standard 464, New York City (MEA), and California State Fire Marshal (CSFM) and Chicago (BFP) See approvals by model in Specifications and Ordering Information • ADA/NFPA/UFC/ANSI compliant • Complies with OSHA 29 Part 1910.165 • Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (Multi-Candela models) or 1575cd (single candela model) • Ceiling mount models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd (Multi-candela models) • Low current draw with temperature compensation to reduce power consumption and wiring costs • Strobes produce 1 flash per second over the regulated voltage range • 24 VDC with wide UL “Regulated Voltage” using filtered DC or unfiltered VRMS input voltage • Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol • Adjustable Volume and Tone Control • Single Stroke or Vibrating Operation • Fast Installation with IN/OUT screw terminals using #12 to #18 AWG wires SERIES CH70 CHIME STROBE SERIES CH90 CHIME Series CH Chimes and Chime Strobes THE CITY OF NEW YORK DEPA RTMENT OF BUILDINGS UL® 151-92-ES5391 7125-0785:151 7135-0785:109 (Chime Only) SERIES CH90 CHIME STROBE SERIES CH70 CHIME Notification Application 1. The chimes are factory set in single stroke (SS) mode. They can be changed to vibrating (VIB) mode with jumper on PC Board. SINGLE STROKE OPERATION: The minimum input pulse duration must be at least 160 ms “on” time and 160 ms “off” time. The chime will only operate once each time it is pulsed. This mode is recommended for coded systems. VIBRATING OPERATION: Continuous input voltage applied to the chime will activate the chime at one-second intervals. 2. The volume and tone controls have been adjusted at the factory to insure maximum dBA output. However, once the mode is selected, the installer may want to fine-tune the signal to better suit the application. 3. Anechoic dBA is measured in an anechoic chamber with peak meter response. Reverberant dBA is rated per UL Standard 464. 4. Chime inrush current is 0.100 amps maximum with filtered DC input (0.140 amps with VRMS input voltage) with a time duration of 100 milliseconds. Table 2: Chime dBA ratings CH70/CH90 sound level Peak dBA @ 10 ft. anechoic dBA @ 10 ft reverberant Min Max 83 52 58 * RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Table 1: Average RMS Current CH70/ CH90 Chimes Chime current CH70 Strobe current - Wall Mount CH90 Strobe current - Ceiling Mount 241575W 24MCW 24MCWH 24MCC 24MCCH 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24 vdc 0.022 0.060 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270 UL max*0.022 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 NOTE: All CAUTIONS and WARNINGS are identified by the symbol . All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their “Regulated Voltage Range”. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • “Regulated Voltage Range” is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology “Listed Voltage Range”. TO NEXT APPLIANCE OR EOLR FROM PRECEDING APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP TO NEXT STROBE OR EOLR CHIMESTROBE (OPTIONAL) +COM-+ + - - -+ + + - FROM PRECEDING APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP F A C P DSM #3 Strobe NAC Cir. DSM #2 DSM #1 Strobe NAC Cir. Strobe NAC Cir. Sync Sync Sync + -+ +- - DSM Interconnecting wiring shown. Maximum of twenty (20) CH CH CH CH CH CH Series PS Power Supplies Series PS Power Supplies EOLR F A C P OUTPUTS 1-4 4-CLASS "B" OR 2-CLASS "A" CH CH CH ST ST ST Wiring Diagrams# For wiring information on the Wheelock Power Supplies, please refer to Data Sheet #9100. SERIES CH CHIME & STROBE OPERATE INDEPEN- DANTLY (NON-SYNC OR SYNC) SERIES CH CHIME STROBES SYNCHRONIZED W/ MULTIPLE DSM MODULES SERIES CH CHIME STROBE APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE “CLASS A” SERIES CH CHIME STROBE APPLIANCES & ST STROBES SYNCHRONIZED WITH WHEELOCK POWER SUPPLIES Note: Figure shows intercon- nection to strobe through sync module. Chime portion requires 2 separate conduc- tors to FACP. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. Model Number Order Code Wall Mount Ceiling Mount Strobe Sync w/ DSM or Wheelock Power Sup- plies Strobe Candela 24 VDC Model Color RED Model Color White Mounting Options Agency Approvals UL MEA CSFM BFP CH70-24MCW-FR 9018 X X 15/30/75/110 X X -L,O,P,Q,R,U,Y X X X X CH70-24MCW-FW 9019 X -X 15/30/75/110 X -X L,O,P,Q,R,U,Y X X X X CH70-24MCWH-FR 9083 X -X 135/185 X X -L,O,P,Q,R,U,Y X X X - CH70-24MCWH-FW 9084 X -X 135/185 X -X L,O,P,Q,R,U,Y X X X - CH70-241575W-FR 7830 X -X 15 (75 on Axis)X X -L,O,P,Q,R,U,Y X X X X CH90-24MCC-FW 3168 -X X 15/30/75/95 X -X Q,U,V X X X - CH90-24MCC-FR 3167 -X X 15/30/75/95 X X -Q,U,V X X X - CH90-24MCCH-FW 3110 -X X 115/177 X -X Q,U,V X X X - CH70-24-R 7825 X X --X X -L,O,P,Q,R,U,Y X X X X CH70-24-W 7827 X X --X -X L,O,P,Q,R,U,Y X X X X CH90-24-W 7826 X X --X -X Q,U,V X X X X CH90-24-R 7828 X X --X X -Q,U,V X X X X Models are available in either Red or White. Call Customer Service for Order Code & Delivery. Specifications and Ordering Information Architects and Engineers Specifications S0710 CH 06/11 The chime appliances shall be Wheelock Series CH Chimes and the chime strobe appliances shall be Wheelock Series CH Chime Strobes or approved equals. The chime shall be UL Listed under Standard 464 for Audible Signal Appliances and chimes equipped with strobes shall be listed under UL Standard 1971 for Emergency Devices for the Hearing-Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class B and shall incorporate low temperature compensation to ensure the lowest possible current consumption. All chimes shall use solid state components and shall provide field selectable single stroke or vibrating operation with volume control and tone control. All models shall have a peak Anechoic sound output of 83 dB at 10 feet and an adjustable frequency range of 800 to 1200 Hz. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The strobe shall be of low current design. Where Multi-Candela Chime Strobes are specified, the strobe intensity shall have a minimum of four (4) field selectable settings and shall be rated per UL Standard 1971 at: 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant and not accessible from the front of the appliance. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required, the strobe portion of the appliance shall be compatible with Wheelock DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of syn- chronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The chime and the chime strobe appliances shall be designed for indoor surface or flush mounting. The chime and chime strobe shall incorporate a chime mounting plate with a grille cover which is secured with two screws for a level, aesthetic finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. All chime and chime strobe appliances shall be backward compatible. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY NotificationCooper Notification is NJ Location 273 Branchport Ave. Long Branch, NJ 07740 P: 800-631-2148 F: 732-222-8707 www.coopernotification.com