HomeMy WebLinkAboutPLANS 2 - 21-00358 - Madison Memorial Hospital Behavioral HealthSHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l ERICA R ANENSON NICET LEVEL III #135963 EXISTING SYSTEM SEQUENCE OF OPERATIONS PROJECT DIRECTORY APPLICABLE CODES & STANDARDS ABBREVIATIONS LEGEND GENERAL NOTES LEGENDSDRAWING INDEX DEVICE TAG LEGEND SCOPE OF WORK FIRE ALARM SYSTEM BEHAVIORAL HEALTH-TI MADISON MEMORIAL HOSPITAL ·FA: = FACP (NON-NETWORK) ·#: = NODE NUMBER ·T#: = TRANSPONDER NUMBER ·#:T# = NODE:TRANSPONDER NUMBER ·N#: = NAC EXTENDER NUMBER DEVICE NUMBER ·D# = DOOR HOLDER CIRCUIT NUMBER ·F# = FIRE PHONE CIRCUIT ·H# = AUDIBLE (HORN) CIRCUIT NUMBER ·M# = IDNET LOOP NUMBER ·P# = POWER CIRCUIT NUMBER ·S# = SPEAKER CIRCUIT NUMBER ·V# = VISUAL CIRCUIT NUMBER ·Z# = ZONE NUMBER ·(L#) = IDNET ISOLATED LOOP NUMBER BRANCH / ISOLATED LOOP DESIGNATOR: CIRCUIT DESIGNATOR PANEL DESIGNATOR 1:T2:V12-1(L1) 1.THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS IS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 2.SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO AS NOT TO IMPAIR THE CONSTRUCTION SCHEDULE. 3.CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. 4.A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION. 5.THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. 6.UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO JOHNSON CONTROLS NO LATER THAN 7 DAYS AFTER FINAL TEST. 7.THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER. 8.DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL REPRESENTATIVE. 9.ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 10.THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. 11.INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND APPLICABLE ELECTRICAL CODES. REFER TO 'APPLICABLE CODES & STANDARDS' FOR SPECIFIC CODE REFERENCES. 12.ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES. 13.FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIRE ALARM WIRES IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP. 15.FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. 16.FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS. 17.FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE APPLICABLE ELECTRICAL CODES, WHERE APPLICABLE. 18.ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. 19.ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. 20.ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 21.120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 22.MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS. 23.EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY; HOWEVER, ANY EXISTING CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. JOHNSON CONTROLS MAKES NO STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. PHONE: Sales Representative PETER PETRONI PETER.PETRONI@JCI.COM 208-914-2099 PHONE: Project Manager SHANE LESTEBERG SHANE.LESTEBERG@JCI.COM 208-914-2112 PHONE: Drawings Prepared By ERICA ANENSON ERICA.RAE.ANENSON@JCI.COM PHONE: Drawings Reviewed By KENNETH DEITRICH KENNETH.REID.DEITRICH@JCI.COM 702-408-5898 Site MADISON MEMORIAL HOSPITAL 450 E. MAIN ST. REXBURG, ID 83440-2013 Johnson Controls District - 444 8783 WEST HACKAMORE DRIVE BOISE, ID 83709 PHONE: 208-376-2111 FAX: 208-376-2192 SERVICE: 208-376-2111 MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDING NEW DEVICES, RELOCATE AND DEMO EXISTING DEVICES AS SHOWN ON DRAWINGS. ALL NEW WIRING TO BE CLASS A. THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. OCCUPANCY TYPE(S):SPRINKLER PROTECTION: I-2 INSTITUTIONAL GROUP BUILDING IS FULLY SPRINKLERED JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECK WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. International Fire Code (IFC), 2015 Edition National Fire Alarm Code (NFPA 72), 2016 Edition National Electric Code (NFPA 70), 2017 Edition International Building Code (IBC), 2015 Edition ANSI/ASME A17.1 2010 Elevator Code with State exceptionsFACP NAC1 S F # # WP # AIM S VS C # FIRE ALARM SYMBOL LEGEND SYMBOL DESCRIPTION BRAND MODEL BACKBOX WIRE TYPE PANELS 4100ES FIRE ALARM CONTROL PANEL, 120 VAC SIMPLEX 4100-9111 SIMPLEX CABINET N/A POWERPATH 8AMP NAC EXTENDER W/CLASS A EXPANSION MODULE WHEELOCK PS-8 N/A INITIATING DEVICES ADDRESSABLE PHOTOELECTRIC SMOKE SENSOR W/ STANDARD BASE SIMPLEX 4098-9714 HEAD 4" OCT, 1-1/2" D M 4098-9792 BASE ADDRESSABLE SINGLE ACTION MANUAL PULL STATION SIMPLEX 4099-9004 4" SQ, 2-1/8" D W/ SINGLE GANG COVER M INSTITUTIONAL COVER KIT SIMPLEX 2099-9828 ADDRESSABLE DUCT SMOKE DETECTOR SIMPLEX 4098-9755 MOUNTS TO DUCTWORK M MODULES AND RELAYS INDIVIDUAL ADDRESSABLE MODULE SIMPLEX 4090-9001 SINGLE GANG 2-1/2" D W/COVER M Z NOTIFICATION APPLIANCES CONVENTIONAL STROBE ,CEILING MOUNT, WHITE, CLEAR LENS, FIRE WHEELOCK RSS-24MCC-FW 4" SQ. 1-1/2" D V CONVENTIONAL MULTI-CANDELA CHIME/STROBE ,CEILING MOUNT, WHITE, CLEAR LENS, FIRE WHEELOCK CH90-24MCC-FW 4" SQ. 1-1/2" D W/ 1-1/2" EXT RING V CONVENTIONAL MULTI-CANDELA WEATHERPROOF HORN/STROBE ,WALL MOUNT, RED, CLEAR LENS, FIRE WHEELOCK ASWP-2475W-FR MFG V CONVENTIONAL MULTI-CANDELA HORN/STROBE ,WALL MOUNT, RED, CLEAR LENS, FIRE WHEELOCK MT-24MCW-FR 4" SQ. 2-1/8" D - FLUSH V MISCELLANEOUS DEVICES TAMPER SWITCH BY OTHERS BY OTHERS Z REMOTE TEST STATION SIMPLEX 2098-9806 SINGLE GANG 2"D K ACCEPTABLE CABLE TYPES FIRE ALARM WIRE LEGEND FP L R FP L P TH H N TF F N OU T D O O R * * C. I .CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES B RUI + COMMUNICATION UTP SOLID 18 AWG 58pf/ft. MAX CAPACITANCE, 35.5 Ω TOTAL LINE RESISTANCE X X M IDNET UTP SOLID 18 AWG 60µF MAX TOTAL LINE CAPACITANCE X X P POWER 2 COND. SOLID 14 AWG X X X X V VISUAL 2 COND. SOLID 14 AWG X X CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA 1/2"0.122 SQ. INCH*1-1/4"0.598 SQ INCH* 3/4"0.213 SQ INCH*1-1/2"0.814 SQ INCH* 1"0.346 SQ INCH*2"1.342 SQ INCH* * 40% CONDUIT FILL PER N.E.C.STP = SHIELDED TWISTED PAIR ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST. AC =ABOVE CEILING AFF =ABOVE FINISHED FLOOR AHJ =AUTHORITY HAVING JURISDICTION ALM =ALARM ANN =ANNUNCIATOR BMS =BUILDING MANAGEMENT SYSTEM C =CEILING MOUNTED CD =CANDELA RATING DET =DETECTOR DGP =DATA GATHERING PANEL E =EXISTING TO REMAIN EOL =END OF LINE EPO =EMERGENCY POWER OFF ER =ELEVATOR RECALL FAA =FIRE ALARM ANNUNCIATOR FACP =FIRE ALARM CONTROL PANEL FATC =FIRE ALARM TERMINAL CABINET FBO =FURNISHED BY OTHERS FCC =FIRE COMMAND CENTER FSD =FIRE SMOKE DAMPER FTR =FIRE ALARM TRANSPONDER H =HIGH HUMIDITY HT =HEIGHT HVAC =HEATING VENTILATION & AIR CONDITIONING IMS =INFORMATION MANAGEMENT SYSTEM MAX =MAXIMUM MIN =MINIMUM N/A =NOT APPLICABLE NAC =NOTIFICATION APPLIANCE CIRCUIT NDU =NETWORK DISPLAY UNIT NEC =NATIONAL ELECTRIC CODE NFPA =NATIONAL FIRE PROTECTION ASSOCIATION NIC =NOT IN CONTRACT NPU =NETWORK PROCESSING UNIT NTS =NOT TO SCALE PAP =PRE-ACTION PANEL RC =EXISTING TO REMOVE AND COVER RD =EXISTING DEVICE TO BE RELOCATED RL =RELOCATED DEVICE RR =REMOVE EXISTING & REPLACE WITH NEW SCC =STATUS COMMAND CENTER SLC =SIGNALING LINE CIRCUIT SMK =SMOKE SUPV =SUPERVISORY TAC =TRUEALERT ADDRESSABLE CONTROLLER TOS =TOP OF SHAFT TRBL =TROUBLE TS =TAMPER SWITCH TYP =TYPICAL UON =UNLESS OTHERWISE NOTED VCC =VOICE COMMAND CENTER VT =VALVE TAMPER W =WATTAGE W/=WITH W/O =WITHOUT WF =WATERFLOW WG =WIRE GUARD WP =WEATHERPROOF XP =EXPLOSION PROOF JOHNSON CONTROLS CONTACTS LA S T P R I N T E D : LA S T S A V E D B Y : FI L E P A T H : C: \ U s e r s \ j a n e n s e \ D e s k t o p \ 1 _ O t h e r D i s t r i c t P r o j e c t s \ _ B o i s e J o b s \ M a d i s o n M e m o r i a l \ M M H _ B e h a v i o r a l H e a l t h T I _ 6 5 0 0 4 6 9 7 7 \ F i r e \ F A - 0 0 1 . d w g 4/ 2 0 / 2 0 2 1 1 1 : 5 4 : 4 8 A M JA N E N S E 444:650046977 E.ANENSON DN 3/18/21 FIRE ALARM SYSTEM MA D I S O N M E M O R I A L H O S P I T A L 45 0 E . M A I N S T . RE X B U R G , I D 8 3 4 4 0 - 2 0 1 3 87 8 3 W E S T H A C K A M O R E D R I V E BO I S E , I D 8 3 7 0 9 PH O N E : 2 0 8 - 3 7 6 - 2 1 1 1 SE R V I C E : 2 0 8 - 3 7 6 - 2 1 1 1 FA X : 2 0 8 - 3 7 6 - 2 1 9 2 444046977 DI S T R I C T - 44 4 FA-001 COVER SHEET JOHNSON CONTROLS © 2021 MA D I S O N M E M O R I A L H O S P I T A L BE H A V I O R A L H E A L T H - T I © Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited. IMPORTANT NOTICE TO USER: This information may not be sold or transferred to any third party, used on other projects or additions to the project for which it was prepared, or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use or reuse of altered files by the user or any third party and such use will be a user's sole risk. User shall, to the fullest extent permitted by law, defend, indemnify, and hold Johnson Controls harmless from any and all claims for loss, damage or injury arising directly or indirectly from any such unauthorized use. N VICINITY MAP SCOPE OF WORK Sheet Number Sheet Title General Information (FA-000 Series) FA-001 COVER SHEET Floorplans (FA-100 Series) FA-101 DEVICE PLACEMENT PLAN Risers & Calculations (FA-200 Series) FA-201 RISER DIAGRAM & BATTERY CALCUALTIONS Typical Details (FA-700 Series) FA-701 WIRING TYPICALS B BUSINESS GROUP S-1 STORAGE GROUP SY S T E M O U T P U T S AC T U A T E C O M M O N A L A R M S I G N A L I N D I C A T O R AC T U A T E A U D I B L E A L A R M S I G N A L AC T U A T E C O M M O N S U P E R V I S O R Y S I G N A L I N D I C A T O R AC T U A T E A U D I B L E S U P E R V I S O R Y S I G N A L AC T U A T E C O M M O N T R O U B L E S I G N A L I N D I C A T O R AC T U A T E A U D I B L E T R O U B L E S I G N A L AC T U A T E A P P R O P R I A T E L O C A T I O N I N D I C A T O R AC T U A T E A L L A U D I B L E E V A C U A T I O N S I G N A L S AC T U A T E A L L V I S I B L E E V A C U A T I O N S I G N A L S UN U S E D DI S P L A Y C H A N G E O F S T A T U S TR A N S M I T A L A R M S I G N A L T O S U P E R V I S I N G S T A T I O N TR A N S M I T S U P E R V I S O R Y S I G N A L T O S U P E R V I S I N G S T A T I O N TR A N S M I T T R O U B L E S I G N A L T O S U P E R V I S I N G S T A T I O N UN L O C K S E C U R I T Y D O O R S RE L E A S E E L E V A T O R F I R E D O O R S MA I N F L O O R E L E V A T O R R E C A L L AL T E R N A T E F L O O R E L E V A T O R R E C A L L EL E V A T O R H A T F L A S H EL E V A T O R S H U N T T R I P RE L E A S E M A G N E T I C A L L Y H E L D S M O K E D O O R S FA N S H U T D O W N DA M P E R S H U T D O W N RE M O T E L Y D I S P L A Y A C T I V E S T A T U S CTRL UNIT ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL SYSTEM INPUTS A B C D E F G H I J K L M N O P Q R S T U V W X 1 SMOKE SENSOR/DETECTOR X X X X X X X X X X X X 2 MANUAL PULL STATION X X X X X X X X 3 DUCT SENSOR/DETECTOR - SUPERVISORY X X X X X X X 4 MAIN FLR. ELEV. LOBBY SMOKE DETECTOR X X X X X X X X X X X X X X 5 ELEVATOR LOBBY SMOKE DETECTORS (EXC. MAIN FLR)X X X X X X X X X X X X X X 6 ELEVATOR MECH. ROOM HEAT DETECTOR X X X X X X X X X 7 ELEVATOR MECH. ROOM SMOKE DETECTOR X X X X X X X X X X X X X X 8 ELEVATOR SHAFT HEAT DETECTOR X X X X X X X X X 9 ELEVATOR SHAFT SMOKE DETECTOR X X X X X X X X X X X X X X 10 ELEVATOR POWER MONITOR X X X X X X 11 WATERFLOW SWITCH X X X X X X X X X X 12 TAMPER SWITCH X X X X X X 13 GENERATOR RUNNING X X X X X X 14 GENERATOR FAULT X X X X X X 15 FIRE ALARM AC POWER FAILURE X X X X X 16 FIRE ALARM SYSTEM LOW BATTERY X X X X X 17 OPEN CIRCUIT OR GROUND FAULT X X X X X 18 CLASS A NOTIFICATION CIRCUIT (NAC) - SHORT X X X X X 1 04 / 2 0 / 2 1 DN ER A CH A N G E S P E R C U S T O M E R R E Q U E S T 1 1 1 TABLETABLE TABLETABLE 2697 Suppression Fire 2680A Office 2681 Room Break 2679 Workroom Biomed. Tech. 2673 Office I.S. 2671 Office I.S. Office RT 2653 Expansion Pharmacy 2666 Hallway 2660 Corridor 2670 Room Data 2668 Office I.S. 2667 Office I.S. 2659 Workroom I.S. IT02 IT Room 2654 Pharmacy 2647 Corridor 2656 Storage 2658 Office 2652 Pharmacy Expansion 2657 Toilet 2655 Office 2649 Corridor 2664 Hold Soiled 2662 Dryers 2661 Clean Laundry 2699 Office Housekeeping 2696 Office 2695 Corridor 2698 Corridor 2704 Mechanical Electrical/ 2702 Storage 2703 Storage 2700 Storage 2701 Storage H002 Elevator 201 RECEPTION STAIR TEAM ROOM 236 CORRIDOR 239 221 220 212 CORRIDOR DAY ROOM 206 T.R. 219 T.R. 2627 213 THERAPY 207 SECLUSION 204 234 STORAGE232 T.R.231 T.R. 2250 Pool Equip. 2251 Exam2254 Men's Toilet 2255 Toilet Women's 2252 Whirlpool2253 Whirlpool 2256 Open Storage 2249 P.T. Room Meeting Storage 2257 Office P.T. 2263 Storage Education 2258 O2 Fill Gas 2240 Toilet O.T. 2241 O.T.Exam 2259 Exam 2260 Exam 2261 Exam 2245 Area Equipment P.T Open 2228 Corridor 2057 Chiller 2056 Boiler Mechanical/ SMOKE ZONE 2-5 IT01 Meeting 210 NURSE STATION 218 T.R. DUAL OCCUPANT PATIENT ROOM 217 DUAL OCCUPANT PATIENT ROOM DIRECTOR'S OFFICE 211 GROUP THERAPY/DINING 212 CORRIDOR 208 OBSERVATION/SECURITY VEST. 203 VISITING 200 EXISTING CORRIDOR SHARED DOCTOR'S OFFICE 202 SECURITY VESTIBULE235 MEDIA CENTER 233 DUAL OCCUPANT PATIENT ROOM 230 DUAL OCCUPANT PATIENT ROOM 228 T.R.229 SINGLE OCCUPANT PATIENT ROOM 225 T.R. 224 T.R. 226 SINGLE OCCUPANT PATIENT ROOM 223 DUAL OCCUPANT PATIENT ROOM 222 SECURITY VESTIBULE 227 CORRIDOR 216 CORRIDOR 248 EVS 241 STAFF T.R. 240 NURSE STATION 242 237 NURSES WORKROOM 238 MED STORAGE/ DISPENSARY 215 EXAM EXISTING STAIR SA NAC20:V1-1 NAC20 S1:M1-5 S 1:M1-6 S 1:M1-1 FACP F A T C NAC1 NAC3 NAC2 NAC4 15 15 30 NAC2:V3-2 75 NAC20:V1-215 NAC2:V3-10 15 NAC2:V3-11 15 NAC2:V3-9 15 NAC2:V3-7 15 NAC2:V3-4 15 NAC2:V3-6 15 NAC2:V3-5 15 NAC2:V3-3 15 15 15 15 15 AOM 1:M1-7 EX. P S1:M1-8 S1:M1-16 S1:M1-17 F A T C 15 FACP S 1:M3-89 1:M3-90 EX. AOM P 1: M 3 - 8 4 EX. AOM P 1: M 3 - 8 7 EX. AOM P 1: M 3 - 8 8 EX. S 1:M1-5 S 1:M1-11 S 1:M1-12 75 N7:V1-7 15 N7:V1-8 DH DH 15 15 S 1:M1-4 S 1:M1-2 1:M1-1 EX. M,P TO NAC2:V3 V V V V V V V V V V S 1:M1-1 JB MM M,P M,P M,P 75 NAC2:V3-1 V TO NAC2:V3 JB V V V TO NAC20 LOCATED BY IT ROOM 110 N7:V1-5 75 N7:V1-6 1:M1-21 10K S 2:M1-9 S 2:M1-10 P 10K 2K K R M,P M,P S 2:M1-14 S 2:M1-17 S R2:M1-16 S R 2:M1-15 R R S R 2:M1-13 R R M,PM,PM,PM,PM,PM,P M,P M,P M,P F 1:M5-81 NAC1:V1-9 15 NAC1:V1-11 15 NAC3:V3-4 15 NAC1:V1-2 30 S 1:M5-88 S 1:M5-87 S 1:M5-84 S 1:M5-86 S 1:M5-82 S 1:M5-83 S 1:M5-80 S 1:M5-79 S 1:M5-89 75 WP NAC1:V3-2 S 1:M5-91 30 NAC1:V3-3 75 NAC1:V3-1 FAA M,P M,P M,P M,P M,P M,P M,P M,P M,P M,P M,P V V V V FEED FROM NAC1:V3 RETURN TO NAC1:V3 V FEED FROM NAC1:V1 V FEED FROM NAC3:V3 RETURN TO NAC3:V3 RETURN TO NAC1:V1 V V V V V V V V V V V V V V V V V V V V V V V M,P EXISTING FEED FROM 1:M5 CKT TIE INTO EXISTING 1:M5 CKT K S 1:M5-85 AIM 1:M5-77 VS M,P M,P F 1:M5-90 C NAC3:V3-5 15 C NAC3:V3-6 15 C NAC3:V3-7 15 C NAC3:V3-8 15 C NAC3:V3-9 15 C NAC3:V3-2 15 C NAC3:V3-3 15 C NAC1:V1-3 15 C NAC1:V1-4 15 C NAC1:V1-5 15 C NAC1:V1-6 30 C NAC1:V1-7 75 C NAC1:V1-8 30 C NAC1:V1-10 15 NIC 1 1 22 4 5 3 3 2 2 6 6 SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l ERICA R ANENSON NICET LEVEL III #135963 0 SCALE:IN FEET1/8" = 1'-0" 4'8'16' N SCALE:1/8" = 1'-0" DEVICE PLACEMENT PLAN LA S T P R I N T E D : LA S T S A V E D B Y : FI L E P A T H : C: \ U s e r s \ j a n e n s e \ D e s k t o p \ 1 _ O t h e r D i s t r i c t P r o j e c t s \ _ B o i s e J o b s \ M a d i s o n M e m o r i a l \ M M H _ B e h a v i o r a l H e a l t h T I _ 6 5 0 0 4 6 9 7 7 \ F i r e \ F A - 1 0 1 . d w g 4/ 2 0 / 2 0 2 1 1 1 : 5 4 : 5 3 A M JA N E N S E 444:650046977 E.ANENSON DN 3/18/21 FIRE ALARM SYSTEM MA D I S O N M E M O R I A L H O S P I T A L 45 0 E . M A I N S T . RE X B U R G , I D 8 3 4 4 0 - 2 0 1 3 87 8 3 W E S T H A C K A M O R E D R I V E BO I S E , I D 8 3 7 0 9 PH O N E : 2 0 8 - 3 7 6 - 2 1 1 1 SE R V I C E : 2 0 8 - 3 7 6 - 2 1 1 1 FA X : 2 0 8 - 3 7 6 - 2 1 9 2 444046977 DI S T R I C T - 44 4 FA-101 DEVICE PLACEMENT PLAN JOHNSON CONTROLS © 2021 MA D I S O N M E M O R I A L H O S P I T A L BE H A V I O R A L H E A L T H - T I © Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited. FACP NAC1 S F # # WP # AIM S VS C # FIRE ALARM SYMBOL LEGEND SYMBOL DESCRIPTION BRAND MODEL BACKBOX WIRE TYPE PANELS 4100ES FIRE ALARM CONTROL PANEL, 120 VAC SIMPLEX 4100-9111 SIMPLEX CABINET N/A POWERPATH 8AMP NAC EXTENDER W/CLASS A EXPANSION MODULE WHEELOCK PS-8 N/A INITIATING DEVICES ADDRESSABLE PHOTOELECTRIC SMOKE SENSOR W/ STANDARD BASE SIMPLEX 4098-9714 HEAD 4" OCT, 1-1/2" D M 4098-9792 BASE ADDRESSABLE SINGLE ACTION MANUAL PULL STATION SIMPLEX 4099-9004 4" SQ, 2-1/8" D W/ SINGLE GANG COVER M INSTITUTIONAL COVER KIT SIMPLEX 2099-9828 ADDRESSABLE DUCT SMOKE DETECTOR SIMPLEX 4098-9755 MOUNTS TO DUCTWORK M MODULES AND RELAYS INDIVIDUAL ADDRESSABLE MODULE SIMPLEX 4090-9001 SINGLE GANG 2-1/2" D W/COVER M Z NOTIFICATION APPLIANCES CONVENTIONAL STROBE ,CEILING MOUNT, WHITE, CLEAR LENS, FIRE WHEELOCK RSS-24MCC-FW 4" SQ. 1-1/2" D V CONVENTIONAL MULTI-CANDELA CHIME/STROBE ,CEILING MOUNT, WHITE, CLEAR LENS, FIRE WHEELOCK CH90-24MCC-FW 4" SQ. 1-1/2" D W/ 1-1/2" EXT RING V CONVENTIONAL MULTI-CANDELA WEATHERPROOF HORN/STROBE ,WALL MOUNT, RED, CLEAR LENS, FIRE WHEELOCK ASWP-2475W-FR MFG V CONVENTIONAL MULTI-CANDELA HORN/STROBE ,WALL MOUNT, RED, CLEAR LENS, FIRE WHEELOCK MT-24MCW-FR 4" SQ. 2-1/8" D - FLUSH V MISCELLANEOUS DEVICES TAMPER SWITCH BY OTHERS BY OTHERS Z REMOTE TEST STATION SIMPLEX 2098-9806 SINGLE GANG 2"D K ACCEPTABLE CABLE TYPES FIRE ALARM WIRE LEGEND FP L R FP L P TH H N TF F N OU T D O O R * * C. I .CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES B RUI + COMMUNICATION UTP SOLID 18 AWG 58pf/ft. MAX CAPACITANCE, 35.5 Ω TOTAL LINE RESISTANCE X X M IDNET UTP SOLID 18 AWG 60µF MAX TOTAL LINE CAPACITANCE X X P POWER 2 COND. SOLID 14 AWG X X X X V VISUAL 2 COND. SOLID 14 AWG X X CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA 1/2"0.122 SQ. INCH*1-1/4"0.598 SQ INCH* 3/4"0.213 SQ INCH*1-1/2"0.814 SQ INCH* 1"0.346 SQ INCH*2"1.342 SQ INCH* * 40% CONDUIT FILL PER N.E.C.STP = SHIELDED TWISTED PAIR ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST. GENERAL NOTES: 1.ALL CEILINGS ARE ASSUMED TO BE 10' A.F.F., SMOOTH CONSTRUCTION UNLESS NOTED OTHERWISE. 2.THE DEVICE ADDRESSES INDICATED ON THESE DRAWINGS ARE AN ALPHANUMERIC DESCRIPTION OF WHICH CIRCUIT THE DEVICE IS LOCATED ON. DEVICES MAY BE ASSIGNED A DIFFERENT NUMBER WITHIN THE PANEL PROGRAM. CONSULT WITH A JOHNSON CONTROLS TECHNICIAN BEFORE APPLYING A PHYSICAL LABEL TO ANY DEVICES. 3.ALL EXISTING CIRCUITING WITHIN THE SCOPE OF WORK AREA WILL BE REMOVED DURING DEMO AND NEW WIRING WILL BE INSTALLED FOR CIRCUITS. 4.EXISTING EQUIPMENT, DEVICES AND WIRING ARE REPRESENTED IN A LIGHTER COLOR (GRAY) AND ARE TO REMAIN AS-IS UNLESS OTHERWISE NOTED. 5.NEW EQUIPMENT, DEVICES AND WIRING ARE REPRESENTED IN A BOLD COLOR (BLACK) AND ARE TO BE INSTALLED AS DIRECTED ON PLANS KEYNOTES: TIE SLC CIRCUITS INTO CLOSEST EXISTING 1:M5 DEVICE. CIRCUIT INTEGRITY TO BE KEPT FOR CIRCUITING. ALSO TIE INTO EXISTING POWER CIRCUITING IF NECESSARY. EXISTING CIRCUITING REMOVED FROM DEMO. NEW CIRCUITING TO BE HOMERUN TO/FROM NAC1 (WHEELOCK PS-8) FOR EXISTING WHEELOCK NOTIFICATION DEVICES. EXISTING CIRCUITING REMOVED FROM DEMO. NEW CIRCUITING TO BE HOMERUN TO/FROM NAC3 (WHEELOCK PS-8) FOR EXISTING WHEELOCK NOTIFICATION DEVICES. CURRENT LOCATION OF NODE1, NAC1 & NAC3 PANELS. RELOCATE EXISTING NURSE STATION FAA TO THIS LOCATION. KEEP EXISTING RUI & POWER CIRCUITS AS-IS. EXISTING DEVICE TO REMAIN. WIRE INTO IDNET 1:M5 CIRCUIT. 1 2 3 4 5 6 SCALE: KEY PLAN NTS SCOPE OF WORK AREA N 1 04 / 2 0 / 2 1 DN ER A CH A N G E S P E R C U S T O M E R R E Q U E S T 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LEVEL 1 LEVEL 1 IDNet - 1:M5 S 1: M 5 - 7 9 F 1: M 5 - 8 1 S 1: M 5 - 8 0 S 1: M 5 - 8 2 S 1: M 5 - 8 3 S 1: M 5 - 8 4 S 1: M 5 - 8 5 S 1: M 5 - 8 7 S 1: M 5 - 8 8 S 1: M 5 - 8 9 NAC1:V175 NAC 1 : V 3 - 1 75 WP NAC 1 : V 3 - 2 30 NAC 1 : V 3 - 3 NAC1:V2 NAC 1 : V 1 - 2 30 NAC 1 : V 1 - 9 15 NAC 1 : V 1 - 1 1 15 NAC3:V3 NA C 3 : V 3 - 4 15 M 1 SS P 4100ES EXISTING NODE 1 FACP 120 VOLT AC EXISTING 1:M5 DEVICES EXISTING 1:M5 DEVICES M M 1 SS P 120 VOLT AC PS-8 EXISTING WHEELOCK PS1 LOCATED IN 1ST FLOOR MECH CORR LOCATED IN 1ST FLOOR MECH CORR V V V V V V S 1: M 5 - 9 1 K S 1: M 5 - 8 6 AIM 1: M 5 - 7 7 VS Z 6.8K 1 SS P 120 VOLT AC PS-8 EXISTING WHEELOCK PS3 LOCATED IN 1ST FLOOR MECH CORR F 1: M 5 - 9 0 C NA C 3 : V 3 - 9 30 C NA C 3 : V 3 - 8 75 C NA C 3 : V 3 - 7 15 C NA C 3 : V 3 - 6 15 C NA C 3 : V 3 - 5 15 C NA C 3 : V 3 - 3 15 C NA C 3 : V 3 - 2 15 C NAC 1 : V 1 - 1 0 15 C NAC 1 : V 1 - 8 30 C NAC 1 : V 1 - 7 75 C NAC 1 : V 1 - 6 30 C NAC 1 : V 1 - 5 15 C NAC 1 : V 1 - 4 15 C NAC 1 : V 1 - 3 15 SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l ERICA R ANENSON NICET LEVEL III #135963 SCALE: RISER DIAGRAM N.T.S. LA S T P R I N T E D : LA S T S A V E D B Y : FI L E P A T H : C: \ U s e r s \ j a n e n s e \ D e s k t o p \ 1 _ O t h e r D i s t r i c t P r o j e c t s \ _ B o i s e J o b s \ M a d i s o n M e m o r i a l \ M M H _ B e h a v i o r a l H e a l t h T I _ 6 5 0 0 4 6 9 7 7 \ F i r e \ F A - 2 0 1 . d w g 4/ 2 0 / 2 0 2 1 1 1 : 5 4 : 5 5 A M JA N E N S E 444:650046977 E.ANENSON DN 3/18/21 FIRE ALARM SYSTEM MA D I S O N M E M O R I A L H O S P I T A L 45 0 E . M A I N S T . RE X B U R G , I D 8 3 4 4 0 - 2 0 1 3 87 8 3 W E S T H A C K A M O R E D R I V E BO I S E , I D 8 3 7 0 9 PH O N E : 2 0 8 - 3 7 6 - 2 1 1 1 SE R V I C E : 2 0 8 - 3 7 6 - 2 1 1 1 FA X : 2 0 8 - 3 7 6 - 2 1 9 2 444046977 DI S T R I C T - 44 4 FA-201 RISER DIAGRAM & BATTERY CALCUALTIONS JOHNSON CONTROLS © 2021 MA D I S O N M E M O R I A L H O S P I T A L BE H A V I O R A L H E A L T H - T I © Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited. RISER NOTES: 1.RISER IS A DIAGRAMMATICAL REPRESENTATION OF THE SYSTEM ARCHITECTURE IN BUILDING CROSS SECTION. IT IS NOT INTENDED TO REPRESENT ACTUAL WIRE RUNS, PANEL CONFIGURATIONS OR PENETRATIONS. REFER TO FLOOR PLANS AND PANEL DETAILS FOR CIRCUIT ROUTING AND CONFIGURATION INFORMATION. 2.ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICAL CODES. REFER TO 'APPLICABLE CODES & STANDARDS' ON SHEET FA-001 FOR SPECIFIC CODE REFERENCES. KEYED NOTES: 120VAC PRIMARY POWER SOURCE SHALL BE A MECHANICALLY PROTECTED BRANCH CIRCUIT. THE CIRCUIT DISCONNECTING MEANS SHALL HAVE A RED MARKING, AND BE IDENTIFIED AS "FIRE ALARM CIRCUIT" 1 FACP NAC1 S F # # WP # AIM S VS C # FIRE ALARM SYMBOL LEGEND SYMBOL DESCRIPTION BRAND MODEL BACKBOX WIRE TYPE PANELS 4100ES FIRE ALARM CONTROL PANEL, 120 VAC SIMPLEX 4100-9111 SIMPLEX CABINET N/A POWERPATH 8AMP NAC EXTENDER W/CLASS A EXPANSION MODULE WHEELOCK PS-8 N/A INITIATING DEVICES ADDRESSABLE PHOTOELECTRIC SMOKE SENSOR W/ STANDARD BASE SIMPLEX 4098-9714 HEAD 4" OCT, 1-1/2" D M 4098-9792 BASE ADDRESSABLE SINGLE ACTION MANUAL PULL STATION SIMPLEX 4099-9004 4" SQ, 2-1/8" D W/ SINGLE GANG COVER M INSTITUTIONAL COVER KIT SIMPLEX 2099-9828 ADDRESSABLE DUCT SMOKE DETECTOR SIMPLEX 4098-9755 MOUNTS TO DUCTWORK M MODULES AND RELAYS INDIVIDUAL ADDRESSABLE MODULE SIMPLEX 4090-9001 SINGLE GANG 2-1/2" D W/COVER M Z NOTIFICATION APPLIANCES CONVENTIONAL STROBE ,CEILING MOUNT, WHITE, CLEAR LENS, FIRE WHEELOCK RSS-24MCC-FW 4" SQ. 1-1/2" D V CONVENTIONAL MULTI-CANDELA CHIME/STROBE ,CEILING MOUNT, WHITE, CLEAR LENS, FIRE WHEELOCK CH90-24MCC-FW 4" SQ. 1-1/2" D W/ 1-1/2" EXT RING V CONVENTIONAL MULTI-CANDELA WEATHERPROOF HORN/STROBE ,WALL MOUNT, RED, CLEAR LENS, FIRE WHEELOCK ASWP-2475W-FR MFG V CONVENTIONAL MULTI-CANDELA HORN/STROBE ,WALL MOUNT, RED, CLEAR LENS, FIRE WHEELOCK MT-24MCW-FR 4" SQ. 2-1/8" D - FLUSH V MISCELLANEOUS DEVICES TAMPER SWITCH BY OTHERS BY OTHERS Z REMOTE TEST STATION SIMPLEX 2098-9806 SINGLE GANG 2"D K ACCEPTABLE CABLE TYPES FIRE ALARM WIRE LEGEND FP L R FP L P TH H N TF F N OU T D O O R * * C. I .CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES B RUI + COMMUNICATION UTP SOLID 18 AWG 58pf/ft. MAX CAPACITANCE, 35.5 Ω TOTAL LINE RESISTANCE X X M IDNET UTP SOLID 18 AWG 60µF MAX TOTAL LINE CAPACITANCE X X P POWER 2 COND. SOLID 14 AWG X X X X V VISUAL 2 COND. SOLID 14 AWG X X CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA 1/2"0.122 SQ. INCH*1-1/4"0.598 SQ INCH* 3/4"0.213 SQ INCH*1-1/2"0.814 SQ INCH* 1"0.346 SQ INCH*2"1.342 SQ INCH* * 40% CONDUIT FILL PER N.E.C.STP = SHIELDED TWISTED PAIR ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST. MADISON MEMORIAL HOSPITAL - NAC1 1ST FLR PS-8 NAC EXTENDER Standby Total Alarm Total Module Qty Description Current Standby Current Alarm Panel Equipment PS-8 1 POWERPATH 8-AMP NAC EXTENDER 0.1290 0.1290 0.1290 0.1290 PS-EXP 1 CLASS A EXPANSION MODULE 0.0000 0.0000 0.0000 0.0000 Panel Totals 0.1290 0.1290 Notification Appliances Setting ASWP-2475W-FR 1 WP HORN STROBE 75CD, 24VDC WALL, RED WP75 0.0000 0.0000 0.1680 0.1680 CH90-24MCC-FW 4 MULTI-CD CHIME STROBE, CEILING, WHITE 15 0.0000 0.0000 0.0870 0.3480 CH90-24MCC-FW 2 MULTI-CD CHIME STROBE, CEILING, WHITE 30 0.0000 0.0000 0.1270 0.2540 CH90-24MCC-FW 1 MULTI-CD CHIME STROBE, CEILING, WHITE 75 0.0000 0.0000 0.2110 0.2110 MT-24MCW-FR 1 MULTI TONE, MCD HORN/STROBE, WALL, RED 30 0.0000 0.0000 0.0920 0.0920 MT-24MCW-FR 1 MULTI TONE, MCD HORN/STROBE, WALL, RED 75 0.0000 0.0000 0.1650 0.1650 RSS-24MCC-FW 2 MULTI CD STROBE, CEILING, WHITE 15 0.0000 0.0000 0.0650 0.1300 RSS-24MCC-FW 1 MULTI CD STROBE, CEILING, WHITE 30 0.0000 0.0000 0.1050 0.1050 Peripheral Totals 0.0000 1.4730 Added Current for EPS Conversion of 24 to 29 Volt IDNac Devices 0.0000 0.0000 RUI Totals 0 0.0000 0.0000 Address Totals 0 Addresses 0.0000 0.0000 System Totals*:Standby 0.1290 Alarm 1.6020 Standby Standby Alarm Alarm Battery Set #1 (Cabinet/Charger #1)Current Total Current Total Select ALL Power Supplies on this battery set: PS-8 0.1290 1.6020 Sub Total 0.1290 1.6020 Total 0.1290 1.6020 Standby Time =24 Hrs x 0.1290 = 3.0960 Standby Ah Alarm Time =5 Min 0.08333 x 1.602 = 0.1335 Alarm Ah 3.2295 Additional Spare Battery Capacity =0%+0.0000 3.2295 Battery Discharge Factor =20%+0.6459 Minimum Battery Required 2081-9272 6.2AH (2x)3.8754 Battery Supplied 2081-9274 10AH (2x) * System Totals represent total system current requirements. Those currents may be distributed between multiple battery sets or power supplies as shown above. MADISON MEMORIAL HOSPITAL - NAC1 1ST FLR PS-8 NAC EXTENDER VOLTAGE DROPS PID CH90-24MCC-FW CH90-24MCC-FW CH90-24MCC-FW RSS-24MCC-FW RSS-24MCC-FW ASWP-2475W-FR MT-24MCW-FR MT-24MCW-FR Setting 15cd 30cd 75cd 15cd 30cd WP75 30cd 75cd WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED STRANDED COPPER WIRE) @ 75 Celsius Device Type MC CEIL A/V MC CEIL A/V MC CEIL A/V MC CEIL V/O MC CEIL V/O A/V MC A/V MC A/V Supv. Current 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Alarm Current 0.0870 0.1270 0.2110 0.0650 0.1050 0.1680 0.0920 0.1650 Alarm Current @ 23 Volts 0.0870 0.1270 0.2110 0.0650 0.1050 0.1680 0.0920 0.1650 Power Panel Plan Dist. (D)Wire Wire Res.Total V. Drop Volt % Volt Min Device Max NOTIFICATION CIRCUIT DESCRIPTION Supply Circuit Ckt.Feet Gauge / Ft. (R)Alarm (A)(A*2D*R)@ End Drop Voltage Distance BEHAVIORAL HEALTH CKT 1 PS-8 SIG1 SIG3 425 14ga 0.0031 1.048 2.797 16.703 14.34%16vdc 532 Ft.4 2 1 2 1 UNKNOWN EXISTING PS-8 SIG2 SIG4 14ga 0.0031 0.000 0.000 19.500 0.00%16vdc 0 Ft. EXISTING WHEELOCK BH CKT PS-8 SIG3 SIG5 375 14ga 0.0031 0.425 1.001 18.499 5.13%16vdc 1311 Ft.1 1 1 UNKNOWN EXISTING PS-8 SIG4 SIG6 14ga 0.0031 0.000 0.000 19.500 0.00%16vdc 0 Ft. NOTE: LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN OF SAFETY, TAKING INTO CONSIDERATION THAT THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT LENGTH, CONTACT YOUR LOCAL JOHNSON CONTROLS DISTRICT OFFICE. SCALE: NAC 1 BATTTERY CALCULATIONS N.T.S. MADISON MEMORIAL HOSPITAL - NAC3 1ST FLR PS-8 NAC EXTENDER Standby Total Alarm Total Module Qty Description Current Standby Current Alarm Panel Equipment PS-8 1 POWERPATH 8-AMP NAC EXTENDER 0.1290 0.1290 0.1290 0.1290 PS-EXP 1 CLASS A EXPANSION MODULE 0.0000 0.0000 0.0000 0.0000 Panel Totals 0.1290 0.1290 Notification Appliances Setting CH90-24MCC-FW 5 MULTI-CD CHIME STROBE, CEILING, WHITE 15 0.0000 0.0000 0.0870 0.4350 CH90-24MCC-FW 1 MULTI-CD CHIME STROBE, CEILING, WHITE 30 0.0000 0.0000 0.1270 0.1270 CH90-24MCC-FW 1 MULTI-CD CHIME STROBE, CEILING, WHITE 75 0.0000 0.0000 0.2110 0.2110 RSS-24MCC-FW 1 MULTI CD STROBE, CEILING, WHITE 15 0.0000 0.0000 0.0650 0.0650 Peripheral Totals 0.0000 0.8380 Added Current for EPS Conversion of 24 to 29 Volt IDNac Devices 0.0000 0.0000 RUI Totals 0 0.0000 0.0000 Address Totals 0 Addresses 0.0000 0.0000 System Totals*:Standby 0.1290 Alarm 0.9670 Standby Standby Alarm Alarm Battery Set #1 (Cabinet/Charger #1)Current Total Current Total Select ALL Power Supplies on this battery set: PS-8 0.1290 0.9670 Sub Total 0.1290 0.9670 Total 0.1290 0.9670 Standby Time =24 Hrs x 0.1290 = 3.0960 Standby Ah Alarm Time =5 Min 0.08333 x 0.967 = 0.0806 Alarm Ah 3.1766 Additional Spare Battery Capacity =0%+0.0000 3.1766 Battery Discharge Factor =20%+0.6353 Minimum Battery Required 2081-9272 6.2AH (2x)3.8119 Battery Supplied 2081-9274 10AH (2x) * System Totals represent total system current requirements. Those currents may be distributed between multiple battery sets or power supplies as shown above. MADISON MEMORIAL HOSPITAL - NAC3 1ST FLR PS-8 NAC EXTENDER VOLTAGE DROPS PID CH90-24MCC-FW CH90-24MCC-FW CH90-24MCC-FW RSS-24MCC-FW Setting 15cd 30cd 75cd 15cd WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED STRANDED COPPER WIRE) @ 75 Celsius Device Type MC CEIL A/V MC CEIL A/V MC CEIL A/V MC CEIL V/O Supv. Current 0.0000 0.0000 0.0000 0.0000 Alarm Current 0.0870 0.1270 0.2110 0.0650 Alarm Current @ 23 Volts 0.0870 0.1270 0.2110 0.0650 Power Panel Plan Dist. (D)Wire Wire Res.Total V. Drop Volt % Volt Min Device Max NOTIFICATION CIRCUIT DESCRIPTION Supply Circuit Ckt.Feet Gauge / Ft. (R)Alarm (A)(A*2D*R)@ End Drop Voltage Distance UNKNOWN EXISTING PS-8 SIG1 SIG3 14ga 0.0031 0.000 0.000 19.500 0.00%16vdc 0 Ft. UNKNOWN EXISTING PS-8 SIG2 SIG4 14ga 0.0031 0.000 0.000 19.500 0.00%16vdc 0 Ft. BEHAVIORAL HEALTH CKT 2 PS-8 SIG3 SIG5 400 14ga 0.0031 0.838 2.105 17.395 10.80%16vdc 665 Ft.5 1 1 1 UNKNOWN EXISTING PS-8 SIG4 SIG6 14ga 0.0031 0.000 0.000 19.500 0.00%16vdc 0 Ft. NOTE: LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN OF SAFETY, TAKING INTO CONSIDERATION THAT THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT LENGTH, CONTACT YOUR LOCAL JOHNSON CONTROLS DISTRICT OFFICE. SCALE: NAC 3 BATTTERY CALCULATIONS N.T.S. Madison Memorial Hospital - NODE 1 4100es FACP Standby Total Alarm Total Module Qty Description Current Standby Current Alarm Panel Equipment 4100-9111 1 4100 CONFIG. DOMESTIC 120V *0.3730 0.3730 0.4700 0.4700 4100-6014 1 NETWORK IF CARD, WIRED 0.0460 0.0460 0.0460 0.0460 4100-6038 1 DUAL RS-232 IF CARD 0.1320 0.1320 0.1320 0.1320 4100-1291 2 REMOTE UNIT INTERFACE 0.0850 0.1700 0.0850 0.1700 4100-3206 3 8 RELAYS - 3 AMP 0.0150 0.0450 0.1900 0.5700 4100-6052 1 EVENT REPORTING DACT 0.0300 0.0300 0.0400 0.0400 4100-3102 4 MAPNET MODULE, UP TO 127 PTS *0.2550 1.0200 0.2750 1.1000 4100-6005 1 MASTER CONTROLLER POWER SUPPLY 0.0000 0.0000 0.0000 0.0000 4100-3203 1 8 RELAYS, 3 AMP CONTACTS 0.0250 0.0250 0.2800 0.2800 4100-3103 2 MAPNET ISOLATOR MODULE *0.0500 0.1000 0.0500 0.1000 4100-5125 1 REMOTE POWER SUPPLY W/CHARGER - 120VAC 0.1500 0.1500 0.1850 0.1850 4100-5005 1 ZONE MODULE, 8 IDC, CLASS B 0.0750 0.0750 0.1950 0.1950 4100-5101 2 EXPANSION PWR SUPPLY (XPS) - 120VAC 60HZ 0.0500 0.1000 0.0500 0.1000 4100-5116 1 EXPANSION AUDIO SIGNAL CARD 0.0180 0.0180 0.0800 0.0800 4100-0620 1 TRANSPONDER INTERFACE MODULE 0.0870 0.0870 0.0870 0.0870 Panel Totals 2.3710 3.5550 IDNet Addressable Devices (SLC) 4099-9006 7 ADDRESSABLE DOUBLE ACTION MANUAL STATION, PUSH * Constant current draw of .8mA standby and 1mA alarm per address used. Devices requiring additional current are accounted for in the section labeled "Miscellaneous Peripheral Devices Requiring Additional System Power". 4090-9001 7 IDNET SUPERVISED IAM * 4098-9714 42 TRUEALARM PHOTO SMOKE SENSOR 4098-9733 2 TRUEALARM HEAT SENSOR * 4098-9756 5 TRUEALARM DUCT SMOKE SENSOR W/ RELAY OUTPUT * 4098-9792 40 TRUEALARM SENSOR BASE * 4098-9780 4 TRUEALARM 2 WIRE RELAY SENSOR BASE * Mapnet Addressable Devices (SLC) 2190-9172 2 MAPNET SUPERVISED IAM * 2099-9795 19 MAPNET SINGLE ACTION PULL STATION * 4098-9714 133 TRUEALARM PHOTO SMOKE SENSOR 4098-9733 12 TRUEALARM HEAT SENSOR * 4098-9792 145 TRUEALARM SENSOR BASE * 2190-9170 12 MAPNET ISOLATOR MODULE * Miscellaneous Peripheral Devices That Require (Additional) System Power 4098-9843 5 ENCAPSULATED RELAY PAM-SD 0.0000 0.0000 0.0150 0.0750 4098-9756 5 TRUEALARM DUCT SMOKE SENSOR W/ RELAY OUTPUT 0.0030 0.0150 0.0150 0.0750 4098-9860 4 2-WIRE RELAY FOR USE WITH 4098-9780 SENSOR BASE 0.0000 0.0000 0.0000 0.0000 Peripheral Totals 0.0150 0.1500 Added Current for EPS Conversion of 24 to 29 Volt IDNac Devices 0.0000 0.0000 RUI Totals 0 0.0000 0.0000 Address Totals 234 Addresses 0.3375 0.3509 * Device Address current draw included below (See Additional Current Draws):System Totals*:Standby 2.7235 Alarm 4.0559 1. 2-wire detector alarm current is included in the alarm current of the Initiating Device Circuit. 2. Backup Amplifier assumes Main Amplifier alarm current on failure. Standby Standby Alarm Alarm Battery Set #1 (Cabinet/Charger #1)Current Total Current Total Select ALL Power Supplies on this battery set: SPS-1 2.1360 3.4200 XPS-2 0.0500 0.0500 XPS-3 0.0500 0.0500 RPS-4 0.1500 0.1850 Sub Total 2.3860 3.7050 Additional Current Draws: MAPNET/IDNet Device Address Communication Current 234 x 0.001442 = 0.3375 x 0.001500 = 0.3509 Sub Total 2.7235 4.0559 Spare addressable point capacity 0%0 x 0.001442 = 0.0000 x 0.0015 = 0.0000 Total 2.7235 4.0559 Standby Time =24 Hrs x 2.7235 = 65.3640 Standby Ah Alarm Time =5 Min 0.08333 x 4.0559 = 0.3380 Alarm Ah 65.7020 Additional Spare Battery Capacity =0%+0.0000 65.7020 Battery Discharge Factor =20%+13.1404 Minimum Battery Required 2081-9279 110AH (2x)78.8424 Battery Supplied 2081-9279 110AH (2x) * System Totals represent total system current requirements. Those currents may be distributed between multiple battery sets or power supplies as shown above. IDNET CHANNEL N1:M5 ADDRESSES IN USE: 67 (26.8%) | SPARE ADDRESSES: 183 (73.2%) SWITCH SETTINGS Address Device Type Point Type Location Description 1 2 3 4 5 6 7 8 9 N1:M5-79 PHOTO SMOKE NICU SECURITY VESTIBULE N1:5-79 X X X X X ON N1:M5-80 RPHOTO SMOKE NICU CORRIDOR 236 N1:5-80 X X ON N1:M5-81 ADRPUL PULL NICU BY NURSES STATION N1:5-81 X X X ON N1:M5-82 PHOTO SMOKE NICU CORRDOR 212 N1:5-82 X X X ON N1:M5-83 PHOTO SMOKE NICU DAY ROOM 210 N1:5-83 X X X X ON N1:M5-84 PHOTO SMOKE NICU CORRIDOR 212 N1:5-84 X X X ON N1:M5-85 RPHOTO DUCT NICU DINING DUCT DETECTOR N1:5-85 X X X X ON N1:M5-86 PHOTO SMOKE NICU CORRIDOR 212 N1:5-86 X X X X ON N1:M5-87 PHOTO SMOKE NICU CORRIDOR 216 N1:5-87 X X X X X ON N1:M5-88 PHOTO SMOKE NICU CORRIDOR 227 N1:5-88 X X X ON N1:M5-89 PHOTO SMOKE NICU CORRIDOR 227 N1:5-89 X X X X ON N1:M5-90 ADRPUL PULL AHU HALL BY BACK EXIT N1:5-90 X X X X ON N1:M5-91 PHOTO SMOKE NICU CORRIDOR 236 N1:5-91 X X X X X ON N1:M5-92 REMOVE FROM PROGRAM N1:5-92 X X X X ON N1:M5-93 REMOVE FROM PROGRAM N1:5-93 X X X X X ON N1:M5-94 REMOVE FROM PROGRAM N1:5-94 X X X X X ON SCALE: NODE 1 BATTTERY CALCULATIONS N.T.S. DEVICES AFFECTED IN SCOPE OF WORK AREA. (EXISTING M5-85 & M5-90 DEVICES THAT ARE TO REMAIN WILL KEEP THEIR EXISTING ADDRESSES) 1 1 1 1 1 1 1 1 1 04 / 2 0 / 2 1 DN ER A CH A N G E S P E R C U S T O M E R R E Q U E S T 1 1 SHEET: DRAWN BY: CHECKED BY: JOB #: PROJECT #: DE S C R I P T I O N CA D DA T E MA R K SYSTEM: CH K ISSUE DATE: 30 " x 4 2 " - A r c h E 1 S i z e IS S U E L O G : Re v i s i o n s s h o w n w i t h # s y m b o l ERICA R ANENSON NICET LEVEL III #135963 LA S T P R I N T E D : LA S T S A V E D B Y : FI L E P A T H : C: \ U s e r s \ j a n e n s e \ D e s k t o p \ 1 _ O t h e r D i s t r i c t P r o j e c t s \ _ B o i s e J o b s \ M a d i s o n M e m o r i a l \ M M H _ B e h a v i o r a l H e a l t h T I _ 6 5 0 0 4 6 9 7 7 \ F i r e \ F A - 7 0 1 . d w g 4/ 2 0 / 2 0 2 1 1 1 : 5 5 : 0 1 A M JA N E N S E 444:650046977 E.ANENSON DN 3/18/21 FIRE ALARM SYSTEM MA D I S O N M E M O R I A L H O S P I T A L 45 0 E . M A I N S T . RE X B U R G , I D 8 3 4 4 0 - 2 0 1 3 87 8 3 W E S T H A C K A M O R E D R I V E BO I S E , I D 8 3 7 0 9 PH O N E : 2 0 8 - 3 7 6 - 2 1 1 1 SE R V I C E : 2 0 8 - 3 7 6 - 2 1 1 1 FA X : 2 0 8 - 3 7 6 - 2 1 9 2 444046977 DI S T R I C T - 44 4 FA-701 WIRING TYPICALS JOHNSON CONTROLS © 2021 MA D I S O N M E M O R I A L H O S P I T A L BE H A V I O R A L H E A L T H - T I © Johnson Controls 2021. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited. DEVICE MOUNTING HEIGHT REFERENCE PER NFPA 72 SIDE WALL CEILING VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS 1.MIN DISTANCE IN SLEEPING ROOMS IS 24" (610mm) FROM CEILING TO TOP OF LENS FOR 110CD STROBES WITHIN 16' OF THE PILLOW 2.177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24" (610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. AUDIBLE ONLYAUDIBLE/VISUAL & VISUAL ONLY APPLIANCES SYNCHRONIZE MORE THAN TWO APPLIANCES IN ANY FIELD OF VIEW. NOTE: REFER TO THE PROPER DEVICE INSTALLATION INSTRUCTIONS FOR BACKBOX MOUNTING HEIGHT. NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST EDGE OF THE DETECTOR. THE 4" REQUIREMENT FOR SMOKE DETECTORS HAS BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 CEILING MOUNTED SMOKE/HEAT DETECTOR ACCEPTED HERE HEAT DETECTORS NEVER HERE WALL MOUNTED SMOKE/HEAT DETECTOR 4" (102mm) 4" (102mm)3' (914mm) MINIMUM A/C SUPPLY OR RETURN DIFFUSER FINISHED FLOOR F I R E MAGNETIC DOOR HOLDER FIRE PHONE JACK FOR CEILING HEIGHTS LESS THAN 86" (2180mm), THE VISUAL LENS MOUNTING HEIGHT SHALL BE WITHIN 6" (150mm) OF THE CEILING. 96" MAX (ADA, IBC, NFPA) (2440mm MAX) ABOVE FINISHED FLOOR TO TOP OF LENS 48" MAX (ADA) (1219mm) 48" MAX (NFPA, ADA) (1219mm MAX) 42" MIN (NFPA) (1067mm MIN) MEASUREMENTS SHOWN ARE TO TOP OF PULL HANDLE MANUAL PULL STATION TO EXIT DOOR 5' (MAX.) (1524mm) DOOR WIDTH LESS 3" (76mm) 5" (127mm)90" MIN (2286mm MIN) ABOVE FINISHED FLOOR (OTHER MOUNTING HEIGHTS SHALL BE PERMITTED BY THE AHJ PROVIDING IT MEETS THE SOUND LEVEL OUTPUT REQUIRED.) NFPA 72 AUDIBLE APPLIANCE 6" MIN (152.4mm MIN) BELOW FINISHED CEILING F I R E FINISHED WALL 12" (305mm) MAXIMUM TO TOP OF SENSOR 80" MIN (ADA, IBC, NFPA) (2032mm MIN) ABOVE FINISHED FLOOR TO BOTTOM OF LENS 0=OFF1=ON 241 242 244 245 243 240 247 248 250 251 249 253 254 255 252 246 193 194 196 197 195 209 210 211 212 213 192 208 145 146 148 149 147 161 162 163 164 165 144 160 176 177 178 179 180 181 199 200 202 203 201 215 216 217 218 219 205 206 207 221 222 223 204 220 151 152 154 155 153 167 168 169 170 171 157 158 159 173 174 175 156 172 183 184 185 186 187 188 189 190 191 150 166 182 198 214 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 1286432 7 86 842 423 5 16 ADDRESS SHOWN ABOVE IS 120 1 ON 1OFF 129 130 132 133 131 97 98 100 101 99 113 114 115 116 117 96 112 128 81 82 84 85 83 49 50 52 53 51 65 66 67 68 69 48 64 80 135 136 139 138 137 103 104 106 107 105 119 120 121 122 123 142 141 143 109 110 111 125 126 127 108 124 140 87 88 91 90 89 55 56 58 59 57 71 72 73 74 75 94 93 95 61 62 63 77 78 79 60 76 92 54 70 86 102 118 134 33 34 36 37 35 1 2 4 5 3 17 18 19 20 21 0 16 32 39 40 43 42 41 7 8 10 11 9 23 24 25 26 27 46 45 47 13 14 15 29 30 31 12 28 44 6 22 38 DIP SWITCHES 5 THRU 8 DO NOT USE ADDRESS 0 FOR AN IDNET ADDRESS 9 NOTE: THE 4098-9771, -9794, -9795, -9798 SOUNDER BASES HAVE A 9-POSITION DIP SWITCH. THE FIRST EIGHT DIP SWITCHES SET THE SOUNDER BASE ADDRESS. DIP SWITCH POSITION 9 IS SET TO OFF OR ON DEPENDING UPON THE SOUNDER BASE POWER SOURCE. WHEN THE SOUNDER BASE IS CONNECTED TO A 24 VDC POWER SOURCE, DIP SWITCH POSITION 9 IS SET TO “OFF” AND THE 24 VDC POWER IS SUPERVISED BY THE SOUNDER BASE. WHEN THE SOUNDER BASE IS POWERED BY THE PANEL’S NOTIFICATION APPLIANCE CIRCUIT (NAC), DIP SWITCH POSITION 9 IS SET TO “ON” AND THE POWER IS SUPERVISED BY THE NAC AND NOT THE SOUNDER BASE. THE 4098-9770 AND -9797 BASES HAVE THE SAME LAYOUT, BUT DOESN’T OFFER SOUNDER FUNCTIONALITY. THEY USE AN 8-WAY DIP SWITCH ONLY. SEE NOTE DIP SWITCHES 1 THRU 4 DIP SWITCH SETTINGS - INITIATING SIMPLEX IDNet 0=OFF BA U D 64 87 16 8 4 534 2 1ON 1 2 ADDRESS SHOWN ABOVE IS 56 6 32 DO NOT USE ADDRESS 0 FOR A RUI ADDRESS 114 113 117 116 115 112 119 118 81 82 84 85 83 66 65 69 68 67 8064 49 50 33 34 52 53 36 37 35 51 18 17 21 20 19 3216 48 87 88 91 90 89 72 71 75 74 73 94 93 95 78 77 79 9276 55 56 39 40 59 58 43 42 41 57 24 23 27 26 25 62 61 46 45 6347 30 29 31 4428 60 3822 867054 DIP SWITCHES 1 THRU 4 102 108 111 110 109 105 107 106 104 103 96 99 101 100 98 971 2 4 5 3 0 7 8 11 10 9 14 13 15 12 6 OFF 1=ON DIP SWITCHES 5 THRU 8 COMMUNICATIONS DIP SWITCH SETTINGS SIMPLEX RUI (REMOTE UNIT INTERFACE) 1.MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. 2.ALWAYS CUT CONDUCTORS AND SECURE UNDER TERMINALS. NEVER LOOP WIRES UNDER TERMINALS. 3.ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJ APPROVED METHODS. WIRING NOTES TOP OF PULL HANDLE TO BE MOUNTED AT 42" - 48" A.F.F. 1.FOR ADDITIONAL MOUNTING OPTIONS, DOWNLOAD DATA SHEET 4099-0005 FROM HTTP://WWW.SIMPLEX-FIRE.COM ALARMFIRE PULL DOWN 12 34 IDNet SLC (-) (+) IDNet SLC (RETURN) (-) (+) ADDRESSABLE PULL STATIONS 12 34 CLASS A WIRING TERMINATION VIEW: DEVICE REAR PUSH 4099-9005 BREAKGLASS 4099-9006 PUSH WITH 2099-9828 INSTITUTIONAL COVER KIT 4099-9004 SINGLE ACTION 4099-9021 NO GRIP SINGLE ACTION 4099-9805 NO GRIP RETROFIT KIT MOUNTING OPTION "B" SIMPLEX 4099 SERIES MOUNTING OPTIONS OPTION 1 DESCRIPTION NOTE A SINGLE GANG BOX, 2-1/2" (64mm) DEEP BY OTHERS B 4" (102mm) SQUARE BOX, 2-1/8" DEEP (MIN) W/ SINGLE GANG COVER PLATE 3/4" (19mm) EXTENSION BY OTHERS C SIMPLEX 2975-9022 - 5H x 3-7/8"W x 2-3/16"D (127mm x 98mm x 56mm)ORDERED SEPARATELY D SIMPLEX 2975-9178 - 5-3/4"H x 3-7/8"W x 2-3/16"D (132mm x 102mm x 56mm)ORDERED SEPARATELY KEY OPERATED ONLY 1.MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. 2.ALWAYS CUT CONDUCTORS AND SECURE UNDER TERMINALS. NEVER LOOP WIRES UNDER TERMINALS. 3.ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJ APPROVED METHODS. WIRING NOTES 1.FOR ADDITIONAL MOUNTING OPTIONS, SEE MANUFACTURER DATA SHEET. CLASS A WIRING - 2 WIRE CONFIGURATION MOUNTING OPTION "A" TERMINATION VIEW: SPEAKER MOUNTING PLATE (+) (-) (+) (-) (-)(+) VIS (-)(+) VIS TO NEXT DEVICE OR RETURN TO FACP MOUNTING OPTION "B" CONVENTIONAL NOTIFICATION APPLIANCES WHEELOCK MT-24MCW SERIES WALL MOUNTED HORN/STROBE (-)(+) AUD (-)(+) AUD WHEELOCK IOB-R (2)WOOD SCREWS (4)#8-18X1" SCREWS (4)SCREW COVERS MOUNTING OPTIONS OPTION1 DESCRIPTION NOTE A 4" (102mm) SQUARE BOX, 2-1/8" (54mm) DEEP - FLUSH MOUNTING BY OTHERS B WHEELOCK IOB-R SURFACE MOUNT BOX2 MANUFACTURER ELECTRICAL BOX (2)#8-18X1" SCREWS (4)SCREW COVERS NAC CIRCUIT 1.MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. 2.ALWAYS CUT CONDUCTORS AND SECURE UNDER TERMINALS. NEVER LOOP WIRES UNDER TERMINALS. 3.ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJ APPROVED METHODS. WIRING NOTES IDNet SLC (-) (+) (-) (+) STANDARD SENSOR BASE TERMINATION VIEW: DEVICE REAR CLASS A WIRING SENSOR IDNet SLC (RETURN) 3' (941mm) MIN.4" (102mm) CEILING MOUNTED SENSOR HEAT SENSORS NEVER HERE 12"(305mm) MAXIMUM TO TOP OF SENSOR FINISHED WALL WALL MOUNTED SENSOR MOUNTING OPTION "A" SIMPLEX 4098-9792 1.FOR ADDITIONAL MOUNTING OPTIONS, DOWNLOAD DATA SHEET 4098-0019 FROM HTTP://WWW.SIMPLEX-FIRE.COM MOUNTING OPTIONS OPTION 1 DESCRIPTION NOTE A SINGLE GANG BOX, 2-1/8" (54mm) DEEP - FLUSH MOUNT BY OTHERS B 4" (102mm) OCTAGONAL BOX, 1-1/2" (38mm) DEEP, MINIMUM - FLUSH MOUNT BY OTHERS C 4" (102mm) SQUARE BOX, 1-1/2" DEEP (MIN) W/ SIMPLEX 4098-9832 ADAPTER KIT BOX BY OTHERS, 4098-9832 ORDERED SEPARATELY D 4" (102mm) SQUARE BOX, 1-1/2" DEEP (MIN) W/ SINGLE GANG COVER PLATE 3/4" (19mm) EXTENSION BY OTHERS BASE ELECTRICAL BOX #6-32 SCREW WITH WASHER (NOT SUPPLIED) #8-32 x 1-1/4" PANHEAD MACHINE SCREW (TIGHTEN TO 4-6 in.-lbs.) MOUNTING OPTION "B" 1.MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. 2.ALWAYS CUT CONDUCTORS AND SECURE UNDER TERMINALS. NEVER LOOP WIRES UNDER TERMINALS. 3.ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJ APPROVED METHODS. WIRING NOTES 1.FOR ADDITIONAL MOUNTING OPTIONS, DOWNLOAD DATA SHEET P83911 FROM HTTP://WWW.COOPERINDUSTRIES.COM STROBE CIRCUIT (+) (-) (+) (-) CONVENTIONAL NOTIFICATION APPLIANCES TERMINATION VIEW: REAR OF DEVICE CLASS A WIRING STROBE CIRCUIT (RETURN) MOUNTING OPTION "A" STROBE INTENSITY SETTING VIEWABLE THROUGH THE LENS ELECTRICAL BOX PROVIDED BY ELECTRICAL CONTRACTOR.STROBE MOUNTING PLATE (SMP) #8-32 X 3/4" SCREWS BEAUTY PLATE (SUPPLIED) WHEELOCK RSS SERIES WALL AND CEILING MOUNTED VISUAL MOUNTING OPTIONS OPTION1 DESCRIPTION NOTE A 4" (102mm) SQUARE BOX, 1-1/2" (38mm) DEEP - FLUSH MOUNTING BY OTHERS B WHEELOCK SHBB SURFACE MOUNT BOX MANUFACTURER 1 1 04 / 2 0 / 2 1 DN ER A CH A N G E S P E R C U S T O M E R R E Q U E S T 1 1.MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. 2.ALWAYS CUT CONDUCTORS AND SECURE UNDER TERMINALS. NEVER LOOP WIRES UNDER TERMINALS. 3.ANY WIRE SPLICES TO BE MADE BY LISTED AND AHJ APPROVED METHODS. WIRING NOTES 1.FOR ADDITIONAL MOUNTING OPTIONS, SEE MANUFACTURER DATA SHEET. 2.BACKBOX IS COMPATIBLE WITH WIREMOLD AND CONDUIT. CLASS B WIRING MOUNTING OPTION "A" STROBE CIRCUIT (-) (+) (-) TERMINATION VIEW: DEVICE MOUNTING PLATE AUDIO CIRCUIT (+) (-) (+) (-) (-)(+)(+)(-) AUD STRB (-)(+)(+)(-) AUD STRB TO NEXT DEVICE OR 10K EOL MOUNTING OPTION "B" CONVENTIONAL NOTIFICATION APPLIANCES WHEELOCK HS4 SERIES (4-WIRE) WALL & CEILING MOUNTED AUDIBLE / VISUAL (4) SCREW COVERS (2) #8-18x1" SCREWS SCREWS (4) #8-18x1" (4) SCREW COVERS WHEELOCK IOB-R SCREWS (2) WOOD MOUNTING OPTIONS OPTION1 DESCRIPTION NOTE A 4" (102mm) SQUARE BOX, 2-1/8" (54mm) DEEP, WITH 1-1/2" (38mm) EXTENSION RING - FLUSH MOUNTING BY OTHERS B WHEELOCK IOB SURFACE MOUNT BOX2 MANUFACTURER ELECTRICAL BOX