Loading...
HomeMy WebLinkAboutPLAN - 21-00137 - Walmart RemodelGC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC 2 GC2GC2 B1B1B1 OG P 2 OG P 2 D6 OG P 2 D6 OG P 2 D6 OG P 2 D6 OG P 2 D6 OG P 2 D6 OG P 2 D6 CL OG P 2 O OG P 2 D6 OG P 2 D8 OG P 2 D6 OG P 2 D6 OG P 2 D6 O O O DDDD DD DD DD DD DD DD DD DD DD OG P 2 D8 OG P 2 D8 OG P 2 D8 OG P 2 D8 OG P 2 D8 OG P 2 D8 OG P 2 D8 OG P 2 D8 OG P 2 D6 OG P 2 D8 OG P 2 D8 OG P 2 D6 OG P 2 D8 OGP2 D8 OG P 2 D6 DD GM 1 GM 1 GM 1 GM 1 GR 1 GR 1 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G H J K M1.1 1 M1.1 2 M1.1 3 1 1/2" G ETR 3/4" G NEW 3/4" GAS GAS REGULATOR ON ROOF ROUTE 3/4" GAS THRU WALL AT STRUCTURE AND DOWN OUTSIDE OF WALL TO ROOF OF EXPANSION. 4 M1.1 5 M1.1 3/4" G ON ROOF 1 34 5 R I V E R V I E W , W I C H I T A , K S 6 7 2 0 3 T 3 1 6 . 2 6 8 . 0 2 3 0 F 3 1 6 . 2 6 8 . 0 2 0 5 Ar c h i t e c t u r e , I n c . © LK SHEET: DRAWN BY: CHECKED BY: PROTO CYCLE: DOCUMENT DATE: CO N S U L T A N T S ST I P U L A T I O N F O R R E U S E PR O T O : JO B N U M B E R : TH I S D R A W I N G W A S P R E P A R E D F O R US E O N A S P E C I F I C S I T E A T : CO N T E M P O R A N E O U S L Y W I T H I T S I S S U E DA T E O N A N D I T I S N O T SU I T A B L E F O R U S E O N A D I F F E R E N T PR O J E C T S I T E O R A T A L A T E R T I M E . U S E OF T H I S D R A W I N G F O R R E F E R E N C E O R EX A M P L E O N A N O T H E R P R O J E C T RE Q U I R E S T H E S E R V I C E S O F P R O P E R L Y LI C E N S E D A R C H I T E C T S A N D E N G I N E E R S . RE P R O D U C T I O N O F T H I S D R A W I N G F O R RE U S E O N A N O T H E R P R O J E C T I S N O T AU T H O R I Z E D A N D M A Y B E C O N T R A R Y T O TH E L A W . IMPORTANT NOTICE: THIS DRAWING SHALL NOT BE USED FOR CONSTRUCTION UNLESS SEALED, SIGNED AND DATED BY THE LICENSEE IN RESPONSIBLE CHARGE (AOR/EOR). EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. 1/ 1 1 / 2 0 2 1 1 : 1 6 : 4 9 P M M1 OVERALL MECHANICAL PLAN MLB 20 2 9 6 RE X B U R G , I D 12 / 0 4 / 2 0 12/04/20 ST O R E N O : 1 8 7 8 . 2 4 8 18 2 10/30/20 RE X B U R G , I D SEB 14 5 0 N O R T H 2 N D E A S T 1/32" = 1'-0" 1 OVERALL MECHANICAL PLAN 1.GENERAL NOTES ARE APPLICABLE TO ALL MECHANICAL DRAWINGS. 2.PROVIDE ALL MATERIALS FOR A COMPLETE INSTALLATION IN ALL RESPECTS AND READY FOR INTENDED USE AND IN STRICT ACCORDANCE WITH STATE AND LOCAL CODES AND MANUFACTURERS RECOMMENDATIONS. 3.STORE MUST BE KEPT IN OPERATION.ARRANGE ALL WORK TO KEEP DISRUPTIONS TO STORE OPERATIONS TO A MINIMUM. COORDINATE WITH EXISTING AND NEW CONSTRUCTION. PAY ALL NECESSARY FEES AND PERMITS. 4.IF NEW CONSTRUCTION DISRUPTS EXISTING UNDERGROUND SERVICES (GAS, SEWER, DOMESTIC WATER, FIRE SPRINKLER, ETC.), PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO MAINTAIN THEIR PROPER OPERATION. 5.CONTRACTOR IS RESPONSIBLE FOR UTILIZING OWNER APPROVED ROOFING CONTRACTORS FOR CUTTING AND PATCHING ROOF. 6.CONTRACTOR SHALL FURNISH AND INSTALL EXHAUST FANS AND EXHAUST FAN CURBS. CONTRACTOR SHALL INSTALL ALL STRUCTURAL SUPPORTS FOR FANS. REFERENCE ARCHITECTURAL/STRUCTURAL SHEETS FOR DETAILS. 7.IF APPLICABLE, COORDINATE ALL NEW GAS PIPING AND ROOF EQUIPMENT WITH EXISTING GAS PIPING, SKYLIGHTS, AND ROOF EQUIPMENT. FIELD VERIFY EXISTING CONDITIONS. 8.ROOFTOP UNITS BEING ADDED TO EXISTING ROOF STRUCTURE SHALL BE INSTALLED WHEN THE UNITS ARRIVE AT THE JOB SITE. REFERENCE ARCHITECTURAL/STRUCTURAL SHEETS FOR DETAILS. 9.INSTALL VTR'S A MINIMUM OF 24" AND FLUES A MINIMUM OF 36" FROM ROOF EDGE AND/OR PARAPET WALLS. INSTALL VTR'S, FLUES AND EXHAUST FANS A MINIMUM OF 10 FT FROM OUTSIDE AIR INTAKE OF ROOF TOP UNITS. INSTALL EXHAUST FANS AND ROOF TOP UNITS A MINIMUM OF 10 FT FROM ROOF EDGE OR A MINIMUM OF 60" FROM PARAPET WALLS THAT ARE AT LEAST 42" HIGH. 10.COORDINATE LOCATION OF DUCTWORK AND DIFFUSERS WITH LIGHT FIXTURES TO PREVENT EXCESSIVE SHADOWING OF THE SALES OR STOCK FLOORS. LIGHT FIXTURE LOCATIONS TAKE PRECEDENCE. FIELD VERIFY STRUCTURAL CONDITIONS BEFORE FABRICATION OF DUCTWORK. 11.FLEXIBLE DUCT CONNECTIONS TO NEW OR RELOCATED DIFFUSERS AND GRILLES ARE PROHIBITED. INSPECT CONDITION OF EXISTING DUCT AND REPLACE DAMAGED DUCT WITH EQUIVALENT TYPE OF DUCT AS REQUIRED. 12.DUCT SIZES SHOWN ON DRAWINGS ARE NET FREE AREA. CONTRACTOR'S OPTION, ROUND DUCTWORK OF EQUIVALENT FREE AREA MAY BE USED IN LIEU OF RECTANGULAR. INCREASE RECTANGULAR SHEET METAL SIZE AS REQUIRED FOR LINER. REFER TO SPECIFICATIONS FOR THE INSULATION THICKNESS. 13.DUCT SUPPORT AND GRILLE DETAIL IS APPLICABLE THROUGHOUT THE STORE. DO NOT USE FASTENERS THAT PENETRATE ROOF DECK. 14.TYPICAL BRANCH DUCT FITTING DETAIL IS APPLICABLE THROUGHOUT THE STORE. 15.PROVIDE SEISMIC BRACING BASED ON APPROPRIATE SEISMIC ZONE REQUIREMENTS PER SMACNA PUBLISHED SEISMIC DETAILS, LOCAL AND NATIONAL CODES. CONTRACTOR'S RESPONSIBILITY INCLUDES STRUCTURAL ENGINEER'S CERTIFICATION ON DETAILS SUBMITTED FOR PERMITTING. 16.BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK SHALL BE SECURED TO PREVENT FALLING, LOOSENING, OR CREATING DAMAGE OF ANY KIND IN THE FUTURE. 17.COMPLETE ASSET TAGGING PROCESS FOR ALL NEW RTU'S AND AHU'S. REFER TO SPECIFICATIONS. GENERAL NOTESMECHANICAL SYMBOLS RECTANGULAR DUCT 18" WIDE BY 12" DEEP RETURN OR EXHAUST DUCT IN SECTION SUPPLY AIR DIFFUSER WITH ROUND SUPPLY DUCT RETURN OR EXHAUST AIR DIFFUSER WITH ROUND DUCT 12" DIAMETER ROUND DUCT SUPPLY DUCT IN SECTION ELBOW WITH TURNING VANES TEE WITH TURNING VANES ROUND (OR OVAL) ELBOW BRANCH DUCT AND/OR NECK SIZE DIFFUSER OR GRILLE TYPE CFM THERMOSTAT TIMER 12" Ø 18"x12" VOLUME/BALANCE DAMPER TEMP SENSOR CONNECT TO EXISTING EXISTING TO REMAINETR FIRE DAMPERFD CD 24"x24" 450 S-X S T REFER TO SEISMIC RESTRAINT SHEET SR1 FOR INSTALLATION DETAILS. REFER TO THE SPECIFICATIONS FOR FURTHER INFORMATION. SEISMIC NOTES 24 HOURS PRIOR TO SHUTTING DOWN ANY REFRIGERATION SYSTEMS, HVAC SYSTEMS, OR ENERGY MANAGEMENT CONTROLS SYSTEMS, SEND E-MAIL TO NSRM@WALMART.COM. THE E- MAIL SHALL STATE WHAT, WHY, AND WHEN IT IS BEING SHUT DOWN AND HOW LONG IT IS ANTICIPATED TO BE DOWN. THEN SEND A FOLLOW UP E-MAIL TO NSRM@WALMART.COM AFTER THE WORK IS COMPLETE AND THE SYSTEM IS BACK UP AND RUNNING. ALL HVAC WORK ON THIS PROJECT IS TO BE COMPLETED BY A WALMART APPROVED CONTRACTOR. ISSUE BLOCK 1 ADD #1 01/11/21