Loading...
HomeMy WebLinkAboutINFRASTRUCTURE - 21-00094 - 681 W Main St - New Twinhome Bldg A2H MAIN TOWNHOMES REXBURG, IDAHO PROJECT NO. 23154 CIVIL SITEWORK FOR: A PORTION OF THE NE 1/4 OF SECTION 25, T. 6N., R. 39 E.B.M., MADISON COUNTY, IDAHO APPROVED BY: REXBURG - CITY ENGINEERING DEPARTMENT Designed By: EAGLE ROCK NGINEERING CIVIL PLANNING SURVEYING IDAHO FALLS (208) 542-2665 REXBURG (208) 359-2665 January, 2024 G1 LOCATION, VICINTY MAP G2 NOTES/INDEX/ABBREVIATIONS/CONTACTS/DETAILS C1 UTILITY PLAN PLAN PP-1 PLAN AND PROFILE PROJECT LOCATIONW MAIN ST LODGEPOLE ST AI R P O R T R D W 1ST N S 5 t h W CITY OF REXBURGPI O N E E R R D GEMINI DR N 5 t h W VICINITY MAP INDEX NO SCALE IDAHO FALLS REXBURG BLACKFOOT CHUBBUCK TWIN FALLS SUN VALLEY CASCADE McCALL BOISE MOSCOW COUER d' ALENE RUPERT SALMON AMMON ST.ANTHONY ISLAND PARK POCATELLO MOUNTAIN HOME RIGBY IONA SHELLEY PROJECT LOCATION Fi l e L o c a t i o n : \\ 1 9 2 . 1 6 8 . 1 . 5 0 \ e a g l e r o c k e n g i n e e r i n g \ p r o j e c t s \ 2 0 2 3 \ 2 3 1 5 4 2 h m a i n t o w n h o m e s \ 3 . 0 d e s i g n \ 3 . 1 c a d \ 3 . 1 3 f i n a l \ 2 3 1 5 4 c o v e r . d w g Pl o t t e d B y : ma t t p Da t e P l o t t e d : Th u r s d a y , J a n u a r y 2 5 2 0 2 4 a t 0 3 : 3 5 P M 1 G- 2 CO V E R AG L E R O C K N G I N E E R I N G SU R V E Y E D B Y : DR A W N B Y : PR O J E C T N O . AP P R O V E D B Y : DE S C R I P T I O N DA T E RE V I S I O N S 1 2 3 4 5 6 AT T E N T I O N Th i s d o c u m e n t o r a n y p a r t t h e r e o f i n d e t a i l o r d e s i g n c o n c e p t is t h e p r o p e r t y o f E a g l e R o c k E n g i n e e r i n g a n d s h a l l n o t b e co p i e d i n a n y f o r m w i t h o u t t h e w r i t t e n a u t h o r i z a t i o n o f E a g l e Ro c k E n g i n e e r i n g . E SH E E T N O . SH E E T N A M E CI V I L P L A N N I N G S U R V E Y I N G ID A H O F A L L S ( 2 0 8 ) 5 4 2 - 2 6 6 5 RE X B U R G ( 2 0 8 ) 3 5 9 - 2 6 6 5 PR E P A R E D F O R : RE X B U R G M A I N S T R E E T D E S I G N , L L C 2H M A I N T O W N H O M E S AD A M S N A R R MA T T P A T Z E R PA U L S N A R R 23 1 5 4 EL.ELEVATION FF FINISHED FLOOR INV INVERT O.C.ON CENTER REQ'D REQUIRED STD STANDARD TEMP TEMPORARY TYP TYPICAL TBC TOP BACK OF CURB DWG DRAWING FL FLOW LINE OF CURB TFW TOP FRONT OF SIDEWALK TBW TOP BACK OF SIDEWALK X EXISTING BLDG BUILDING GB GRADE BREAK SSMH SANITARY SEWER MANHOLE CB CATCH BASIN MH MANHOLE SD STORM DRAIN CITY OF REXBURG ENGINEERING DEPARTMENT KEITH DAVIDSON (208) 372-2320 DEQ (208) 528-2650 DIGLINE (CALL BEFORE YOU DIG)(811) OR (800) 342-1585 EAGLE ROCK ENGINEERING PROJECT ENGINEER PAUL SNARR (208) 542-2665 PROJECT MANAGER KURT ROLAND (208) 542-2665 ABBREVIATIONS PROJECT CONTACTS ARTCO BASE = 4876.02 X=758847.98 Y=796540.22 PROJECT BENCHMARK Fi l e L o c a t i o n : \\ 1 9 2 . 1 6 8 . 1 . 5 0 \ e a g l e r o c k e n g i n e e r i n g \ p r o j e c t s \ 2 0 2 3 \ 2 3 1 5 4 2 h m a i n t o w n h o m e s \ 3 . 0 d e s i g n \ 3 . 1 c a d \ 3 . 1 3 f i n a l \ 2 3 1 5 4 n o t e s a n d d e t a i l s . d w g Pl o t t e d B y : ma t t p Da t e P l o t t e d : Th u r s d a y , J a n u a r y 2 5 2 0 2 4 a t 0 3 : 3 5 P M 2 G- 2 GE N E R A L N O T E S AG L E R O C K N G I N E E R I N G SU R V E Y E D B Y : DR A W N B Y : PR O J E C T N O . AP P R O V E D B Y : DE S C R I P T I O N DA T E RE V I S I O N S 1 2 3 4 5 6 AT T E N T I O N Th i s d o c u m e n t o r a n y p a r t t h e r e o f i n d e t a i l o r d e s i g n c o n c e p t is t h e p r o p e r t y o f E a g l e R o c k E n g i n e e r i n g a n d s h a l l n o t b e co p i e d i n a n y f o r m w i t h o u t t h e w r i t t e n a u t h o r i z a t i o n o f E a g l e Ro c k E n g i n e e r i n g . E SH E E T N O . SH E E T N A M E CI V I L P L A N N I N G S U R V E Y I N G ID A H O F A L L S ( 2 0 8 ) 5 4 2 - 2 6 6 5 RE X B U R G ( 2 0 8 ) 3 5 9 - 2 6 6 5 PR E P A R E D F O R : RE X B U R G M A I N S T R E E T D E S I G N , L L C 2H M A I N T O W N H O M E S AD A M S N A R R MA T T P A T Z E R PA U L S N A R R 23 1 5 4 ELECTRICAL NOTES: 1.ALL TRAFFIC SIGNING SHALL BE DESIGNED, CONSTRUCTED AND PLACED IN ACCORDANCE WITH THE CURRENT MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) WITH THE FOLLOWING EXCEPTIONS: 2.ALL STOP AND YIELD SIGNS USED IN ANY SUBDIVISION SHALL BE A MINIMUM 30”X 30”. ENGINEER GRADE SHEETING SHALL NOT BE ALLOWED. 3.ALL ROAD NAME AND STREET SIGNS SHALL HAVE A MINIMUM 4” LEGEND. BOTH BACKGROUND AND LEGEND SHALL BE REFLECTIVE STANDARD COLORS WITH WHITE LEGEND AND GREEN BACKGROUND EXCEPT PRIVATE ROADS, WHICH WILL HAVE A BLUE BACKGROUND. 4.SUBSTRATE MATERIAL SHALL BE ALUMINUM; NO FIBERGLASS OR PLASTIC WILL BE ACCEPTED. 5.THE MINIMUM SIZE FOR SPEED LIMIT SIGNS SHALL BE 24”W X 30”L WITH BLACK LEGEND ON WHITE BACKGROUND. 6.POSTS SHALL BE METAL AND SHALL BE ANCHORED WITH A “SOIL TYPE” ANCHOR. NO CONCRETE SHALL BE USED AS AN ANCHOR. POSTS SHALL BE 2”X 2” SQUARE AND SHALL MEET BREAK-A-WAY STANDARDS OF THE STATE OF IDAHO. NO U-CHANNEL SHALL BE USED. 7.THE MINIMUM HEIGHT OF SIGNS SHALL BE 6' FROM THE ROAD SURFACE TO THE BOTTOM OF THE SIGN. 8.MAINTENANCE OF ALL STREET AND TRAFFIC SIGNS WILL BE THE RESPONSIBILITY OF THE DEVELOPER UNTIL THE STREETS ARE OFFICIALLY ACCEPTED FOR MAINTENANCE BY THE CITY OF REXBURG. SIGNING NOTES: GENERAL NOTES: 1.ALL NEW ELECTRICAL FACILITIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CURRENT ROCKY MOUNTAIN POWER SERVICE POLICY. 2.DEVELOPER SHALL COORDINATE WITH UTILITY COMPANIES TO RELOCATE AND/OR REMOVE EXISTING FACILITIES WITHIN THE PROJECT LIMITS MEETING UTILITY DESIGN AND STANDARDS. 3.ALL PVC ELECTRIC CONDUITS SHALL BE PVC SCHEDULE 40. ALL FIBERGLASS CONDUITS SHALL MEET ROCKY MOUNTAIN POWER'S MARKING AND STRENGTH RATING REQUIREMENTS. CONDUIT DIAMETERS SHALL MEET ROCKY MOUNTAIN POWER'S DESIGN. ALL ELBOWS SWEEP RADII SHALL BE 36”, 48” OR 60” DEPENDING ON ROCKY MOUNTAIN POWER'S DESIGN. 4.ALL PRIMARY AND SECONDARY CONDUITS SHALL BE PROVIDED AND INSTALLED BY THE DEVELOPER. 5.TRENCH EXCAVATION AND CONDUIT PLACEMENT SHALL BE IN ACCORDANCE WITH ROCKY MOUNTAIN POWER SERVICE POLICY SPECIFICATIONS AND IN ACCORDANCE WITH OSHA STANDARDS. CONDUIT TRENCH DEPTHS SHALL BE BETWEEN 36” AND 48” (NOT TO EXCEED 60”) AND INCLUDE THE REQUIRED SAND PLACEMENT BELOW AND ABOVE THE PLACED CONDUIT. 6.THE ENGINEER SHALL PROVIDE ALL STAKING AND LAYOUT OF NEW ELECTRICAL FACILITIES INCLUDING POWER POLES. 7.THE CONTACTOR SHALL RETAIN AND PROTECT ALL EXISTING POWER POLES AND ELECTRICAL FACILITIES DURING CONSTRUCTION. 8.THE DEVELOPER SHALL COORDINATE ALL ELECTRICAL CONSTRUCTION WITH ROCKY MOUNTAIN POWER. 9.CLEARANCE BETWEEN OVERHEAD POWER AND NEW BUILDING STRUCTURES SHALL BE MAINTAINED MEETING THE CURRENT ROCKY MOUNTAIN POWER SERVICE POLICY. 10.SEE ROCKY MOUNTAIN POWER ELECTRICAL SITE PLAN FOR OFF-SITE AND ON-SITE ELECTRICAL LAYOUT AND INSTALLATION DETAILS. IN THE EVENT THE FIBER OPTIC UTILITY ELECTS TO USE THE SAME TRENCH, THEY MUST MEET NESC UNDERGROUND UTILITY CLEARANCES. 11.A 15 FOOT WIDE PUBLIC UTILITY EASEMENT IS PERPETUALLY RESERVED WITHIN EACH LOT ALONG ALL ROAD FRONTAGES FOR THE USE OF PUBLIC UTILITIES WITHIN THIS SUBDIVISION. NO PERMANENT STRUCTURES, SIDEWALKS, AND DRIVEWAYS SHALL BE CONSTRUCTED OVER SAID EASEMENT (OTHER THAN CROSSINGS) IN ORDER FOR THE UTILITY COMPANIES TO MAINTAIN. FIRE DEPARTMENT NOTES: 1.TURNING RADIUS (CUL-DE-SACS/HAMMERHEADS) SHALL MEET IFC D103.4. DEAD ENDS SHALL REQUIRE A 96' DIAMETER CUL-DE-SAC FOR TURNING EMERGENCY VEHICLES. THE CUL-DE-SAC DESIGN FOR THIS SUBDIVISION IS DESIGNED WITH A 98' DIAMETER TURNAROUND FROM BACK OF CURBS (96' TURNING WIDTH). 2.FIRE CODE SIGNAGE SHALL BE DETERMINED BY THE FIRE CODE OFFICIAL. WHEN REQUIRED, SIGNS MEETING IFC D103.6 SHALL BE INSTALLED (REQUIRED UPON OFFICIAL OR WHEN STREETS COMING INTO DEAD ENDS ARE LESS THAN 26' IN WIDTH AND THE TURNING RADIUS DOES NOT MEET 96' DIAMETER). 1.UNLESS OTHERWISE SHOWN ON THESE PLANS ALL WORK IS TO BE PERFORMED IN ACCORDANCE TO CITY OF REXBURG STANDARD DRAWINGS AND SPECIFICATIONS. THE CONTRACTOR IS REQUIRED TO MAINTAIN A COMPLETE COPY ON SITE AT ALL TIMES (RESOLUTION 2016-15). 2.ALL DISTANCES AND DATA SHALL BE CHECKED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. IN CASE OF CONFLICT THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY SO THAT CLARIFICATION MAY BE MADE PRIOR TO THE START OF WORK. 3.BASIS OF BEARINGS ARE 2004 CITY GRID. 4.ELEVATIONS SHOWN ARE NAVD 88 DATUM TO FINISHED SURFACE OR PIPE INVERT UNLESS OTHERWISE NOTED. 5.GENERAL LOCATIONS AND SIZES OF UTILITIES ARE SHOWN ON THE PLANS. THEY ARE TO BE USED FOR GENERAL INFORMATION ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY THE APPROPRIATE UTILITY COMPANIES WHEN CONSTRUCTION MIGHT INTERFERE WITH NORMAL OPERATIONS OF ANY UTILITIES. IT SHALL ALSO BE THE CONTRACTORS RESPONSIBILITY TO HAVE THE APPROPRIATE UTILITY COMPANY FIELD-LOCATE ANY UTILITY INSTALLATIONS WHICH MIGHT BE AFFECTED BY CONSTRUCTION PRIOR TO BEGINNING WORK IN THAT AREA. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING SERVICE OF EXISTING UTILITIES AND FOR RESTORING ANY UTILITIES DAMAGED DUE TO CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER. 6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING SOURCES FOR GRANULAR MATERIAL, DISPOSAL SITES, AND ANY ADDITIONAL MATERIAL THAT MAY BE NECESSARY FOR PROPER CONSTRUCTION OF THIS PROJECT. 7.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE ARRANGEMENTS FOR WATER REQUIRED FOR TESTING, COMPACTION AND DUST CONTROL MEASURES. 8.ROCK EXCAVATION MAY BE ENCOUNTERED DURING UTILITY CONSTRUCTION. EVERY EFFORT WAS MADE TO REDUCE UTILITY DEPTH WHILE STILL MEETING REGULATORY REQUIREMENTS. FOR BIDDING PURPOSES CONTACT OWNER FOR TEST HOLE DEPTH OF ROCK. 9.LITTLE DEMOLITION IS REQUIRED ON THIS PROJECT PRIOR TO JOB START. CONTRACTOR/BIDDER TO WALK JOB AND IDENTIFY MINOR DEMOLITION WORK PRIOR TO BIDDING. 10.ALL UTILITY MAIN LINES (WATER, SANITARY SEWER AND STORM DRAINAGE) WITHIN PUBLIC STREETS WILL BE OWNED AND MAINTAINED BY THE CITY AND CONSTRUCTED TO CURRENT CITY OF REXBURG STANDARD DRAWINGS AND SPECIFICATIONS; INSPECTED AND CERTIFIED BY AN ENGINEER, LICENSED IN THE STATE OF IDAHO; AND HAVE “AS-BUILT” DRAWINGS PROVIDED TO THE CITY ENGINEER. FAILURE TO COMPLY WITH THE REQUIREMENTS OF THIS PLAN MAY RESULT IN THE CITY'S WITHHOLDING OF BUILDING PERMITS, CERTIFICATE OF OCCUPANCY, AND WATER OR ELECTRICAL SERVICE. 11.LANDSCAPING SIGNS NOT TO EXCEED 3 FEET IN HEIGHT IN THE CLEAR SIGHT TRIANGLE. 12.THERE SHALL BE A 15-FOOT WIDE PUBLIC UTILITY EASEMENT WITHIN EACH LOT ALONG ALL ROAD/STREET FRONTAGES FOR POWER, PHONE, CABLE, GAS, ETC. (GAS REQUIRES SEPARATE TRENCH). THE EXACT LOCATION OF TRANSFORMERS AND PHONE BOXES WILL BE FIELD DETERMINED BY EACH UTILITY COMPANY AFTER ROADS/STREETS HAVE BEEN CONSTRUCTED TO SUBGRADE AND SIDE SLOPES HAVE BEEN COMPLETED. 13.ALL FRONTAGE PUBLIC UTILITY EASEMENTS (PUE) SHALL BE 15 FEET FROM BACK OF SIDEWALK UNLESS NOTED OTHERWISE. 14.LUMEN/CENTURY LINK/SPARKLIGHT USES THE SAME TRENCH AS ROCKY MOUNTAIN POWER AND REQUIRES CONDUITS (CONTRACTOR SHALL NOTIFY ALL FOR SCHEDULING). POWER DESIGN SHOWN IS PRELIMINARY AND ANY CONSTRUCTION STAKING OF POWER SHALL BE CONFIRMED WITH ROCKY MOUNTAIN POWER FOR FINAL LAYOUT. VERIFY CONDUIT SIZE MEETING ROCKY MOUNTAIN POWER DESIGN PRIOR TO CONSTRUCTION. 15.ALL UTILITIES INCLUDING POWER, PHONE, CABLE, ETC. EXCEPT NATURAL GAS MAY BE IN THE SAME TRENCH. NATURAL GAS MUST BE IN A SEPARATE TRENCH. 16.A 12” SPACING SHALL BE REQUIRED BETWEEN DIFFERENT UTILITIES IN THE SAME TRENCH. 17.CONTRACTOR SHALL CONTACT DIG-LINE AT 811, (800) 342-1585 OR (208) 342-1585 PRIOR TO ANY UTILITY CONSTRUCTION. WATER NOTES: 1.ALL WATER MAINS, SERVICES, AND ALL APPURTENANCES SHALL MEET CURRENT CITY OF REXBURG STANDARD DRAWINGS AND SPECIFICATIONS. THIS SHALL INCLUDE ALL MATERIALS, LABOR, AND INSTALLATION INCLUDING VERTICAL AND HORIZONTAL SEPARATION DISTANCES AND SLOPE REQUIREMENTS. 2.ALL WATER MAIN LINE SHALL BE CLASS 50 DUCTILE IRON MEETING AWWA C-151. 3.MINIMUM COVER OVER ALL WATER LINES SHALL BE 6 FEET. 4.WATER LINE SHALL HAVE A MINIMUM SEPARATION DISTANCE OF TEN (10) FEET FROM ANY SANITARY SEWER OR STORM SEWER MEASURED FROM THE OUTSIDE OF EACH PIPE AS OUTLINED IN THE ISPWC 2020 STANDARD DRAWING SD-407. CROSS AT APPROXIMATELY RIGHT ANGLES WITH FULL PIPE SECTIONS AND MINIMUM OF 1.5 FEET OF VERTICAL SEPARATION. 5.THRUST BLOCKS SHALL BE PLACED AT ALL DIRECTION CHANGES FOR PRESSURE PIPE. 6.FIRE HYDRANTS SHALL HAVE TWO 2-1/2” DIAMETER HOSE NOZZLES AND ONE 4-1/2” DIAMETER HOSE NOZZLE PER CITY STANDARDS. 7.WATER AND SEWER SERVICE LINES ARE SHOWN AT APPROXIMATE LOCATIONS. CONTRACTOR TO CONTACT DIG LINE PRIOR TO ALL EXCAVATION AND FIELD VERIFY LOCATION AND WITH ARCHITECTURAL DRAWINGS (IF APPLICABLE) FOR ANY ADDITIONAL SERVICES REQUIRED. 8.WATER METERS AND PRESSURE REDUCING VALVES - SEE PLUMBING DRAWINGS FOR DETAILS. ALL PLUMBING SHALL MEET THE STATE OF IDAHO PLUMBING CODE. COMMERCIAL BUILDINGS SHALL REQUIRE THE WATER METERS TO BE INSTALLED ON THE INTERIOR AND MOUNTED IN A HORIZONTAL POSITION WITHIN A HEATED MECHANICAL ROOM. 9.CONTRACTOR SHALL INSTALL FIRE LINES/SPRINKLERS MEETING THE CURRENT VERSION OF THE INTERNATIONAL FIRE CODE AND SHALL INCLUDE ALL APPURTENANCES (IF APPLICABLE). 10.IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE AND INSTALL ALL REQUIRED BACKFLOW PREVENTION DEVICES ON WATER SERVICES. 11.ALL WATER MAINS AND APPURTENANCES SHALL BE TESTED FOR PRESSURE, LEAKAGE, AND BACTERIA MEETING CITY AND AWWA STANDARDS AND SHALL BE CLEANED AND DISINFECTED PRIOR TO ACCEPTANCE BY THE CITY FOR DOMESTIC USE. TESTING AND DISINFECTION OF WATER MAINS AND APPURTENANCES SHALL BE IN ACCORDANCE WITH AWWA C651 STANDARDS. AWWA STANDARDS REQUIRE EACH STREET TO BE TESTED INDIVIDUALLY FOR PRESSURE, LEAKAGE, AND BACTERIA. STORM SEWER NOTES: 1.ALL STORM SEWER SHALL MEET CURRENT CITY OF REXBURG STANDARD DRAWINGS AND SPECIFICATIONS. THIS SHALL INCLUDE ALL MATERIALS, LABOR, AND INSTALLATION INCLUDING VERTICAL AND HORIZONTAL SEPARATION DISTANCES AND SLOPE REQUIREMENTS. 2.SEPARATION REQUIREMENTS: WATER LINE SHALL HAVE A MINIMUM SEPARATION DISTANCE OF TEN (10) FEET FROM ANY SANITARY SEWER OR STORM SEWER MEASURED FROM THE OUTSIDE OF EACH PIPE AS OUTLINED IN THE ISPWC 2020 STANDARD DRAWING SD-407. CROSS AT APPROXIMATELY RIGHT ANGLES WITH FULL PIPE SECTIONS AND MINIMUM OF 1.5 FEET OF VERTICAL SEPARATION. 3.STORM DRAIN PIPE SHALL MEET ONE OF THE FOLLOWING: PVC SDR 26 MEETING THE REQUIREMENTS OF ASTM D 3034 FOR DIAMETERS 18” OR LESS, ASTM F 679 FOR DIAMETERS 18” OR GREATER, PVC RIBBED PIPE MEETING THE REQUIREMENTS OF ASTM F 794 MEETING THE CURRENT CITY OF REXBURG STANDARD SPECIFICATIONS AND DRAWINGS. 4.CONTRACTOR SHALL PERFORM TESTING AND CLEANING OF SEWER MAINS MEETING CITY STANDARDS. SANITARY SEWER NOTES: 1.ALL SEWER MAIN SHALL BE PVC SDR 35 IN ACCORDANCE WITH ASTMD3034 AND SERVICE SHALL MEET CURRENT CITY OF REXBURG STANDARD DRAWINGS AND SPECIFICATIONS. THIS SHALL INCLUDE ALL MATERIALS, LABOR, AND INSTALLATION INCLUDING VERTICAL AND HORIZONTAL SEPARATION DISTANCES AND SLOPE REQUIREMENTS. 2.SEPARATION REQUIREMENTS: WATER LINE SHALL HAVE A MINIMUM SEPARATION DISTANCE OF TEN (10) FEET FROM ANY SANITARY SEWER OR STORM SEWER MEASURED FROM THE OUTSIDE OF EACH PIPE AS OUTLINED IN THE ISPWC 2020 STANDARD DRAWING SD-407. CROSS AT APPROXIMATELY RIGHT ANGLES WITH FULL PIPE SECTIONS AND MINIMUM OF 1.5 FEET OF VERTICAL SEPARATION. 3.CONTRACTOR SHALL PERFORM TESTING AND CLEANING OF SEWER MAINS MEETING CITY STANDARDS. SHEET INDEX SHEET #SHEET NAME SHEET TITLE 1 C-2 COVER 2 G-2 GENERAL NOTES 3 C-1 OVERALL SHEET AND DETAILS 4 PP-1 PLAN AND PROFILE 5 D-1 DETAIL X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXXX 6''SS6''SS6''SS6''SS 6''SS 6''SS 6''SS 6''SS 6''SS OHOHOHOHOHOHOHOHOHOHOHOHOH 24''SS24''SS24''SS24''SS24''SS24''SS24''SS24''SS24''SS EO EOEO E O EO EO EO EO EO 6''W 6''W 6''W 6''W 6 ' ' W 6''W 6''W 24 ' ' S S EO EO SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W (8''S S (8 ' ' S S (8 ' ' S S (8 ' ' S S (8 ' ' S S (8 ' ' S S (8''SS (8''SS (8''SS LOT 7 0.11 ACRES LOT 6 0.10 ACRES LOT 5 0.09 ACRESLOT 4 0.08 ACRES 6''W W W W W W W W NELSON LOIS #382169 ALLEN DON INSTRUMENT NO. 403120 WEST MAIN STREET 132.00' INSTALL SSMH #1 EXISTING SSMH RIM=4959.92 INV W IN = 4844.22 INV E IN = 4844.22 (NEW CONNECTION) INV N OUT= 4844.12 SS SS SS SS SS SS 0+ 0 0 1+ 0 0 2+ 0 0 2+ 5 0 0+00 1+00 1+75 INSTALL SSMH #2 INSTALL SSMH #3 SS SS SS SS SS SS SS SS SS SS SS 0+ 0 0 1+ 0 0 2+ 0 0 2+ 5 0 1+750+00 1+00 EVERGREEN SUBDIVISION LOT 10, BLOCK 3 INSTRUMENT NO. #279946 MARQUEX INSTRUMENT NO. 199726 SETBACK LINESETBACK LINE 10" 11' PEDESTRIAN AND UTILITY EASEMENT 20' STARLITE ADDITION BLOCK 1, LOT 2 INSTRUMENT NO. 137316 132.00'132.00' 1187.78' 1320.28' FGF: 4860.50 FGF: 4860.50 FGF: 4860.50 FGF: 4860.50 EO: 4859.70 EO: 4859.70 EO: 4859.50 EO: 4859.50 EO: 4859.50 EO: 4859.75 EO: 4859.90 EO: 4860.00 EO: 4859.50 EO: 4859.45 EO: 4860.00 EO: 4860.00 EO: 4859.50 EO: 4860.00 EO: 4859.50 EO: 4859.40 FL VG: 4858.85 FL VG: 4859.10 FL VG: 4859.50 LOT 4 LOT 5 LOT 6 LOT 7 EO: 4859.25 FOUND CITY BRASS CAP NORTH 1 4 CORNER SECTION 25 T.6N., R.39, E.B.M., CPF #393351 HAMMERHEAD TURN-AROUND NEW HYDRANT PRIVATE ROAD PR I V A T E R O A D 20 ' 2 8 ' R 28'R 1" WATER METER PIT (TYP) LANDSCAPE AREA (TYP) FOUND R/R SPIKE NORTHEAST CORNER SECTION 25 T.6N., R.39, E.B.M., CPF #265165 UTILITY EASEMENT Fi l e L o c a t i o n : \\ 1 9 2 . 1 6 8 . 1 . 5 0 \ e a g l e r o c k e n g i n e e r i n g \ p r o j e c t s \ 2 0 2 3 \ 2 3 1 5 4 2 h m a i n t o w n h o m e s \ 3 . 0 d e s i g n \ 3 . 1 c a d \ 3 . 1 3 f i n a l \ 2 3 1 5 4 o v e r a l l s i t e p l a n . d w g Pl o t t e d B y : ma t t p Da t e P l o t t e d : Th u r s d a y , J a n u a r y 2 5 2 0 2 4 a t 0 3 : 3 6 P M 3 C- 1 OV E R A L L S H E E T A N D D E T A I L S AG L E R O C K N G I N E E R I N G SU R V E Y E D B Y : DR A W N B Y : PR O J E C T N O . AP P R O V E D B Y : DE S C R I P T I O N DA T E RE V I S I O N S 1 2 3 4 5 6 AT T E N T I O N Th i s d o c u m e n t o r a n y p a r t t h e r e o f i n d e t a i l o r d e s i g n c o n c e p t is t h e p r o p e r t y o f E a g l e R o c k E n g i n e e r i n g a n d s h a l l n o t b e co p i e d i n a n y f o r m w i t h o u t t h e w r i t t e n a u t h o r i z a t i o n o f E a g l e Ro c k E n g i n e e r i n g . E SH E E T N O . SH E E T N A M E CI V I L P L A N N I N G S U R V E Y I N G ID A H O F A L L S ( 2 0 8 ) 5 4 2 - 2 6 6 5 RE X B U R G ( 2 0 8 ) 3 5 9 - 2 6 6 5 PR E P A R E D F O R : RE X B U R G M A I N S T R E E T D E S I G N , L L C 2H M A I N T O W N H O M E S AD A M S N A R R MA T T P A T Z E R PA U L S N A R R 23 1 5 4 MATCH ELEVATION MATCH ELEVATION EXISTING WATER PIPE (CONTRACTOR TO VERIFY) W E S N 020'20'10' SCALE: 1" = 20' LEGEND EXISTING WATER LINE EXISTING SEWER LINE EXISTING STORM DRAIN LINE 6''W 6''SS SD SD SD OHP OHP EXISTING ELECTRIC OVERHEAD SECTION LINE PROPERTY LINE ACCESS AND UTILITY EASEMENT LOT LINE 10' UTILITY EASEMENT FRONT OF GARAGE FLOOR UGP UGP EXISTING ELECTRIC UNDERGROUND G G G EXISTING GAS LINE UGTV UGTV EXISTING CATV LINE OHT OHT EXISTING TELE LINE FO FO EXISTING FIBER OPTIC LINE R/W R/W RIGHT-OF-WAY ADJOINING LOT LINE 11' PEDESTRIAN AND UTILITY EASEMENT FGF X X X X X EXISTING FENCE MISC GIRR GIRR EXISTING IRRIGATION LINE LINE DESCRIPTIONLINETYPE, WEIGHT AND COLOR 5' SETBACK EXISTING BUILDING 6' ' S S 6' ' S S 6' ' S S OH OH OH E O EO EO E O SSSSSSSSSSSS SSSSSSSSSS (8 ' ' S S (8''SS (8''SS (8''SS (8''SS (8''SS (8 ' ' S S 6' ' W WWW WWWW 1+00 2+00 2+50 0+ 0 0 1+ 0 0 SSSSSSSSSSSS SSSSSSSSSS 1+00 2+00 2+50 0+ 0 0 1+ 0 0 EO MATCH EO: 4859.50 EO: 4859.50 MATCH MATCH FL VG: 4859.50 EO MATCH EO: 4859.50 FL VG: 4858.86 EO: 4860.00 EO: 4859.40 EO: 4859.50 EO: 4859.50 EO: 4860.00 EO: 4859.25EO: 4859.50 EO: 4859.40 FL VG: 4859.10 EO: 4860.00 45 LF OF 8" PVC @ 0.40% X X X X X X X X X X X X X X X X X X X X X X X OHOHOHOHOHOHOHOH 6''W 6''W 6''W SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W (8 ' ' S S (8 ' ' S S (8''SS (8''SS (8''SS 6''W W W W W SS SS SS SS SS SS 2+ 0 0 1+00 1+75 SS SS SS SS SS SS SS SS 2+ 0 0 1+751+00 EO: 4859.50 EO: 4859.50 EO: 4859.70 EO: 4859.70 EO: 4859.50 FL VG: 4858.86 EO: 4859.40 EO: 4859.50 EO: 4859.50 EO: 4859.25 EO: 4859.50 EO: 4859.40 FL VG: 4859.10 10 LF OF 12" PVC @ 0.22%10 LF OF 12" PVC @ 0.22%10 LF OF 12" PVC @ 0.22%10 LF OF 12" PVC @ 0.22%10 LF OF 12" PVC @ 0.22% 30 LF OF 24" PERFORATED PIPE 4842 4844 4846 4848 4850 4852 4854 4856 4858 4860 4862 4864 4842 4844 4846 4848 4850 4852 4854 4856 4858 4860 4862 4864 0+00 1+00 2+00 2+50 INSTALL SSMH #2 STA:1+88.01 RIM=4858.70 E INV IN=4852.10 N INV OUT=4852.00 146 LF OF 12" PVC @ 0.40% 45 LF OF 8" PVC @ 0.40% (INSTALL DROP CONNECTION INTO EXISTING SSMH) INSATALL SSMH #1 STA:0+41.59 RIM=4859.80 S INV IN=4851.42 NW INV OUT=4851.32 ST A : 0 + 5 4 . 2 8 FL V G E L E V : 4 8 5 9 . 5 0 ' ST A : 1 + 8 3 . 0 1 FL V G E L E V : 4 8 5 8 . 8 5 ' ST A : 2 + 2 0 . 9 6 FL V G E L E V : 4 8 5 9 . 1 0 ' ST A : 2 + 4 3 . 0 1 F0 E L E V : 4 8 6 0 . 0 0 ' 0.66%-0.50%4.08% 12" SW INV OUT=4854.75 CB-1 STA=1+83.01, 0.00' R GRATE=4858.75 12" NE INV IN=4854.73 24" S INV OUT=4853.63 SDMH-1 STA=1+92.18, 3.99' R RIM=4858.80 SUMP: 4852.80 30 LF OF 24" PERFORATED PIPE 10 LF OF 12" PVC @ 0.22% 4842 4844 4846 4848 4850 4852 4854 4856 4858 4860 4862 4864 0+00 1+00 2+00 INSTALL SSMH #2 STA:0+52.52 RIM=4858.70 E INV IN=4852.10 N INV OUT=4852.00 INSTALL SSMH #3 STA:1+51.91 RIM=4859.30 W INV OUT=4852.50 98 LF OF 12" PVC @ 0.40% ST A : 0 + 4 9 . 9 9 FL V G E L E V : 4 8 5 8 . 8 5 ' ST A : 1 + 7 0 . 5 0 EL E V : 4 8 5 9 . 5 0 ' 0.54% EXISTING 6" WATER LINE INSTALL 6" TEE WITH THRUST BLOCK 6' M I N BU R Y INSTALL END CAP AND THRUST BLOCK W E S N SCALE: 1" = 20.0' 20'0 20' W E SN SCALE: 1" = 20.0' 20'0 20' EXISTING SSMH (CONVERSION TO DROP MH) RIM=4959.92 E INV IN = 4844.22 SE INV IN = 4851.14 (NEW DROP MH CONNECTION) N INV OUT= 4844.12 EXISTING GRADE ASPHALT PAVING. SEE DETAIL 1 ON SHEET G-1. SAWCUT AND ASPHALT REPLACEMENT. SEE DETAIL 2 ON SHEET G-1 CONSTRUCTION ITEMS 1 2 SEWER MANHOLE. SEE DETAIL 3 ON SHEET G-13 1 1 2 3 3 3 3 PRIVATE ROAD PRIVATE ROAD NEW FH FIRE HYDRANT.4 4 1" WATER SERVICE (TYP) SEWER SERVICE (TYP) Fi l e L o c a t i o n : \\ 1 9 2 . 1 6 8 . 1 . 5 0 \ e a g l e r o c k e n g i n e e r i n g \ p r o j e c t s \ 2 0 2 3 \ 2 3 1 5 4 2 h m a i n t o w n h o m e s \ 3 . 0 d e s i g n \ 3 . 1 c a d \ 3 . 1 3 f i n a l \ 2 3 1 5 4 p l a n a n d p r o f i l e . d w g Pl o t t e d B y : ma t t p Da t e P l o t t e d : Th u r s d a y , J a n u a r y 2 5 2 0 2 4 a t 0 3 : 3 7 P M 4 PP - 1 PL A N A N D P R O F I L E AG L E R O C K N G I N E E R I N G SU R V E Y E D B Y : DR A W N B Y : PR O J E C T N O . AP P R O V E D B Y : DE S C R I P T I O N DA T E RE V I S I O N S 1 2 3 4 5 6 AT T E N T I O N Th i s d o c u m e n t o r a n y p a r t t h e r e o f i n d e t a i l o r d e s i g n c o n c e p t is t h e p r o p e r t y o f E a g l e R o c k E n g i n e e r i n g a n d s h a l l n o t b e co p i e d i n a n y f o r m w i t h o u t t h e w r i t t e n a u t h o r i z a t i o n o f E a g l e Ro c k E n g i n e e r i n g . E SH E E T N O . SH E E T N A M E CI V I L P L A N N I N G S U R V E Y I N G ID A H O F A L L S ( 2 0 8 ) 5 4 2 - 2 6 6 5 RE X B U R G ( 2 0 8 ) 3 5 9 - 2 6 6 5 PR E P A R E D F O R : RE X B U R G M A I N S T R E E T D E S I G N , L L C 2H M A I N T O W N H O M E S AD A M S N A R R MA T T P A T Z E R PA U L S N A R R 23 1 5 4 EXISTING GRADE END CAP AND THRUST BLOCK Fi l e L o c a t i o n : \\ 1 9 2 . 1 6 8 . 1 . 5 0 \ e a g l e r o c k e n g i n e e r i n g \ p r o j e c t s \ 2 0 2 3 \ 2 3 1 5 4 2 h m a i n t o w n h o m e s \ 3 . 0 d e s i g n \ 3 . 1 c a d \ 3 . 1 3 f i n a l \ 2 3 1 5 4 d e t a i l s . d w g Pl o t t e d B y : ma t t p Da t e P l o t t e d : Th u r s d a y , J a n u a r y 2 5 2 0 2 4 a t 0 3 : 3 7 P M 5 D- 1 DE T A I L AG L E R O C K N G I N E E R I N G SU R V E Y E D B Y : DR A W N B Y : PR O J E C T N O . AP P R O V E D B Y : DE S C R I P T I O N DA T E RE V I S I O N S 1 2 3 4 5 6 AT T E N T I O N Th i s d o c u m e n t o r a n y p a r t t h e r e o f i n d e t a i l o r d e s i g n c o n c e p t is t h e p r o p e r t y o f E a g l e R o c k E n g i n e e r i n g a n d s h a l l n o t b e co p i e d i n a n y f o r m w i t h o u t t h e w r i t t e n a u t h o r i z a t i o n o f E a g l e Ro c k E n g i n e e r i n g . E SH E E T N O . SH E E T N A M E CI V I L P L A N N I N G S U R V E Y I N G ID A H O F A L L S ( 2 0 8 ) 5 4 2 - 2 6 6 5 RE X B U R G ( 2 0 8 ) 3 5 9 - 2 6 6 5 PR E P A R E D F O R : RE X B U R G M A I N S T R E E T D E S I G N , L L C 2H M A I N T O W N H O M E S AD A M S N A R R MA T T P A T Z E R PA U L S N A R R 23 1 5 4 TYPICAL ROAD WAY SECTION1NOT TO SCALE UNDISTURBED EARTH 4" OF 3/4" GRAVEL ROADBASE 2" OF PLANT MIX PAVEMENT SEAL COAT GASKET ALL JOINTS CONCRETE COLLAR FINISHED GRADE FRAME & COVER FL O W SHE L F SH E L F SHE L F PLAN DETAIL SEWER MANHOLE SECTION MANHOLE NOTES: 2. 1. FLEXIBLE RUBBER GASKET PRECAST MONOLITHIC CONCENTRIC CONE SECTION PRECAST CONCRETE MANHOLE-BARREL SECTIONS AS REQ'D PREFABRICATED BASE. UNDISTURBED EARTH 3. - A BE D D I N G RUBBER BOOT PLACE VERTICAL WALL ON UPSTREAM SIDE OF MANHOLE, ROTATED 45 DEGREES. WHERE PVC PIPE IS UTILIZED, INSTALL A RUBBER RING OR GASKET COLLAR WHERE THE PIPE IS IN CONTACT WITH MANHOLE BASE AND/OR MANHOLE CHANNEL, IN ORDER TO INSURE A WATERTIGHT SEAL. UNLESS OTHERWISE SHOWN, MANHOLES SHALL HAVE 0.1 FALL FROM UPSTREAM INVERT TO DOWNSTREAM INVERT. FOR PIPE SLOPES GREATER THAN 2.5% SLOPE, SEE PLAN & PROFILE. INSTALL #4 REBAR IN THE CONCRETE COLLARS MEETING ISPWC STANDARD DRAWING SD-508 3 STANDARD BACKFILL TRENCH & RESURFACING 2 NOT TO SCALE TYP. VALLEY GUTTER4 LEGEND: 1 6" OF 3/4" MINUS CRUSHED CONCRETE.2 AGGREGATE BASE MINIMUM. 4'-0" 2'-0"2'-0" 8" 1 1/2" 8" 2 1 NOT TO SCALE 9" OF PIT RUN INFILTRATION DETAILS5NOT TO SCALE 1' 6' - 6 " ( T Y P . ) 24 " MI N . 36" TYP. BACKFILL WITH NATIVE TOPSOIL COMPACT TO 95% OF STANDARD PROCTOR 24" DIA. PERFORATED CORRUGATED EXTERIOR, SMOOTH INTERIOR HDPE WITH PERFORATIONS 4" O.C. 1" DIAMETER COURSE DRAIN ROCK BACKFILL 2" MIN. - 6" MAX. MEETING CITY OF AMMON STANDARDS CLEAN SAND AND GRAVEL OVER EXCAVATE TO FREE DRAINING MATERIAL SEAL END CAP OR CONCRETE (TYP.) SECTION A-A N.T.S. 36 " MI N . 3.0' TYP.10 ' VARIES 36 " MI N . AA 12" PIPE FROM CATCH BASIN MIN. SLOPE 0.22% SEE CATCH BASIN DETAIL 3 PLAN VIEW N.T.S. 5' 48" MANHOLE IN COMPLIANCE WITH CITY OF AMMON STANDARDS *ALL DRAIN ROCK SHALL BE ENCASED IN SEPARATION FABRIC PERFORATE BOTTOM 2' OF ALL INFILTRATION MANHOLES (ENSURE 2' OF DRAIN ROCK IS INSTALLED AROUND PERIMETER OF MANHOLE) INSTALL MIRAFI 160N NON WOVEN FABRIC (OR EQUAL) SEPARATING DRAIN ROCK AND SOIL MEETING CITY OF AMMON STANDARDS COARSE DRAIN ROCK COARSE DRAIN ROCK COARSE DRAIN ROCK COARSE DRAIN ROCK GENERAL NOTES: 1.SEE DETAIL 7A SHEET D-1 FOR WATER SERVICE AT INFILTRATION BED CROSSING.