HomeMy WebLinkAboutFA COMPLETION - 22-00797 - Madison Station Apartments - Bldg 3FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time or ystem acceptance and approval. /t shall be permined to modify this farm as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Attach additional sheets, data or calculations as Necessary to provide a complete record 1. PROPERTY INFORMATION Name of property: Madison station building 3 Address: 577 train Rexburg Idaho Description Ofpropmly: Aparh m Building Occupancytype: GROUP Name of property representative: Aston Oman, Address: Phone: Fax: E-mail: Authority having jurisdiction over this property: Rexburg FIRE MARSHAL Phone: Fax: E-mail: 2. INSTALLATION, SERVICE, AND TESTING CONTRACTOR INFORMATION Installation contractor for this equipment: 4Sight Security, L.L.C. Address: 6944 Big Bend, Idaho Falls, ID 83406 License or certification number: Contractor: # RCE-37051; ID ELE-SC-021298 Phone: 208-403-1434 F. E-mail: Thes,1041iiihmectartyar, Service organization for this equipment: 4Sight Security, L.L.C. Address: 6944 Big Bend, Idaho Falls, ID 834W License or certification number: Contractor :#RCE-37051; ID ELE-SC-021298 Phone: 208403-1434 To: E-mail: A contract for test and inspection in accordance with NFPAstaMards is in effect as of: Contracted testing company: 4Sight Security, L.L.C. Address: 6944 Big Bend, Idaho Falls, ID 83406 Phone: 20840&1434 Fax: E-mail: Contract expires: RENEW Contract number: N/A Frequency of routine inspections: ANNUAL 3. DESCRIPTION OF SYSTEM OR SERVICE Fire alarm system (nonvoiae) Fire alarm with in -building fun emergency voice alarm communication system (EVACS) Mass notification system (MNS) Combination system, with the following components: Fire alarm EVACS MNS Two-way, in -building, emergency communication system NFPA-_ =,g tr. ,3.L 1.1 o IDf 12, Ceg Or®1CW National Fire Pau: n dix—sbn. Iola Mrm mry b o», obr WI-s-I uvea , Nen M resela. It mry M C `eve aimmmxal eeb x dssr.lg Other (specify): 3. DESCRIPTION OF SYSTEM OR SERVICE (comet ecq NFPA 72 edition: 2017 Additional description ofsystem(s): 3.1 Control Unit Manuf a mrer. Potter Model number: AFC 1000 3.2 MNS ass Notification System This system does not incorporate an 3.2.1 System Type: In -building MNS—combination In -building MNS—smod-alone Wide -area MNS Distributed recipient MNS Other (specify): 3.2.2 System Features: Combination fire alarm/NINS MNS autonomous control unit Wide -area MNS to regional national alerting interface Local operating console (LOC) Direct recipient MNS (DRMNS) Wide -area MNS to DRMNS interface Wide -area MNS to high -power speaker array (HPSA) interface In -building MNS to wide -area MNS interface Other (specify): 3.3System Documentation An owners manual, a copy of the manufacturer's instructions, a written sequence of operation, and a copy of the numbered record drawings are stored on site. Location: FACP 3ASystem Software This system does not have alterable site -specific software. Operating system (executive) software revision level: Site -specific software revision date: Revision completed by: Trevor BLACKSURN A copy of the site -specific software is stored on site. Location: 3.5Off-Premises Signal Transmission transmission. Name of organization receiving amrm signals with phone numbers: Almon: AVANT GUARD MONITORING Supervisory: AVANT GUARD MONITORING Trouble: AVANT GUARD MONITORING Entity m which alarms are re -transmitted: Idaho Falls Fire Method ofre- DIGITAL VIA Stadink Radio transmission: This system does not have off -premises Phone: 877-2W9141 Phone: 877-206-9141 Phone: 877-206-9141 Phone: If Chapter 26, specify the means of transmission from the protected premises to the supervising station: If Chapter 27, specify the type of auxiliary alarm system: Local energy Shunt W red Wheless :°? A'2 7:,J lu 1 M 2 I o 2p1 21 Cgry 02OQ Netmal FM Praeac geeco., ThkIran may M wps] k jo,NEUeI UW o rla_ M rmnq. array rot' wpbe la ram .l valea dWaapcn. 4. CIRCUITS AND PATHWAYS 4.1 Signaling Line Pathways 4.1.1 Pathways Class Designations and Survivability Pathways class: N/A Survivability level: Quantity: (See NFPA 72, Sections 12.3 and 12.4) 4.12 Pathways Utilizing Two or More Media Quantity: 0 Description: N/A 4.1.3 Device Power Pathways No separate power pathways from the signaling line pathway Power pathways are separate but of the same pathway classification as the signaling line pathway Power pathways are separate and different classification from the signaling line pathway 4.1A Isolation Modules Quantity: 0 4.2Alam Initiating Device Pathways 41.1 Pathways Class Designations and Survivability Pathways class: C Survivability level: I Quantity: I (See NFPA 72, Sections 12.3 and 12.4) 422 Pathways Utilizing Twoor More Media Quality: I Description: ALARM INITIATING AND NAC'S RUN TOGETHER 4.2.3 Device Power Pathways No separate power pathways from the initiating device pathway Power pathways are separate but ofthe same pathway classification as the initiating device pathway Power pathways are separate and different classification from the initiating device pathway 43 Noa-Voice Audible System Pathways 43.1 Pathways Class Designations and Survivability Pathways class: B Survivability level: I Quantity: 12 (See NFPA 72, Sections 12.3 and I2,4) 432 Pathways Utilizing Two or More Media Quantity' 12 Description: ALARM INITIATING AND NAC'S RUN TOGETHER 4.3.3 Appliance Power Pathways No separate power pathways from the notification appliance pathway Power pathways are separate but of the same pathway classification m the notification appliance pathway Power pathways are separate and different classification from the notification appliance pathway ',IPA-' - '_ - - Ccgmga�e2N9 Ntlpnvl F're PmlecponAuoaNbn. ¶iie r maybap.Por uM,., we dM Um fm revab. a mry ml eemP. so a iii.sl vale p dissftion. S. ALARM INITIATING DEVICES 5.1 Manual Initiating Devices 5.1.1 Manual Fire Alarm Boxes This system does not have manual fire alarm boxes. Type and number of devices: Addressable: I Conventional: Coded: Transmitter: Other (specify): 5.12 Other Alarm Boxes This system does not have other alarm boxes. Description: Type and number of devices: Addressable: Conventional: Coded: Transmitter: Other (specify): 5.2 Automatic Initiating Devices 5.2.1 Smoke Detectors This system does not have smoke detectors. Type and number of devices: Addressable: 2 Conventional: Other(specify): Type of coverage: Complete area Partial area Norman red partial area Other(specify): Type of smoke detector sensing technology: Ionization Photoelectric Multicriteria Aspirating Beam Other(specify): &22 Duct Smoke Detectors % This system does not have alarm -causing duct smoke detectors. Type and number of devices: Addressable: Conventional: Other (specify): Type of coverage: Type of smoke detector sensing technology: Ionization Photoelectric Aspirating Beam 523 Radiant Energy (Flame) Detectors This system does not have radiant energy detectors. Type and number of devices: Addressable: Conventional: Other (specify): Type of coverage: 5.2A Gas Detectors This system does not have gas detectors. Type ofdetectons): Number of devices: Addressable: Conventional: Type of coverage: 525 Heat Detectors This system does not have heat detectors. Type and number of devices: Addressable: Conventional: Type of coverage: Complete area Partial area Nonrequired partial area Linear Spot Type of heat detector sensing technology: Fixed temperature Rate -of -rise Rate compensated 3PoY 0H Nelianal Fire PM nAaentialion.riardm mrybmpietl br MMd-1 une MMrn18iM reWe.lrmrynol pe ¢yyy rwammemel8alea tlielnWlien. 5. ALARM INITIATING DEVICES (continued) 52.6 Addressable Monitoring Modules Number of devices: 5.2.7 Watertlow Alarm Devices devices. Type and number of devices: Addressable: 1 Conventional: 5.2.8 Alarm Verification alarm verification. Number of devices subject w alarm verification: l 53.9 Presignal Number of devices subject to povditnal: Describe presignal functions: 5.2.10 Positive Alarm Sequence(PAS) Describe PAS: 6.211 Other Initiating Devices Describe: This system does not have monitoring modules. This system does have water6ow alarm Coded: Transmitter: This system does have incorporate Alarm verification set for seconds This system does not incorporate pre -signal. This system does not incorporate PAS. This system does not have other initiating devices. 6. SUPERVISORY SIGNAL -INITIATING DEVICES 61 Sprinkler System Supervisory Devices This system does not have sprinkler supervisory devices Type and number of devices:Addressable: 2 Conventional: Coded: Transmitter: Other (specify): 63 Fire Pump Descriptlon and Supervisory Devices This system does not have afire pump. Type fire pump: Electric pump Engine Type and number of devices: Addressable: Conventional: Coded: Transmitter: Other(specify): 6.2.1 Fire Pump Functions Supervised Power Running Phase reversal Selector switch not in auto Engine or control panel trouble Low fuel Other (specify): S3 Duct Smoke Detectors (DSDs) This system does not have DSOs causing supervisory signals. Type and number of devices:Addressable: 0 Conventional: Other (specify): Type of coverage: Type of smoke detector sensing technology: Ionization Photoelectric Aspirating Beam 6A Other Supervisory Devices This system does not have other supervisory devices. Describe: NFPA 72 Fig. 10. 132 I 1 p g - _ C Pgiem®20as Ne rare Prolegin Psto W_ Tho rmm roar � Id rw iMNWal a alas Ron ne r.vak. n rob ro le u W r m-messsl vak a dl&ll n. 7. MONITORED SYSTEMS 71 Engine -Driven Generator 7.1.1 Generator Functions Supervised Engine or control panel trouble Generator running Other (specify): 72 Special Hazard Suppression Systems Description of special hazard system(s): 73 Other Monitoring Systems Description of special hazard system(s): 8. ANNUNCIATORS &1 Location and Description of Annunciators Location I: Location 2: Location 3: This system does not have agenerator. Selector switch not in auto Low fuel This system does not monitor special hazard systems, This system does not monitor other systems. This system does not have annunciators. S. ALARM NOTIFICATION APPLIANCES 9.1 In -Building Fire Emergency Voice Alarm Court munication System This system does not have an EVACS. Number of single voice about channels: Number of multiple voice alarm channels: Number of speakers: Number of speaker circuits: Location of amplification and sound -processing equipment: Location of paging microphone stations: Location I: Location 2: Location 3: 92 Nnnvoee Notification Appllances Homy: 36 With visible: 48 Hells: With visible; Chimes: With visible: Visible only: Other (describe): 93 NotNkation Appliance PowerEmender Panels This system does have power maunder panels, Quantity: t Locations: flier room Ccpy40M1t 02 09 N.—I Fee Pmlectian s,eueses, n o net, mry ee tt "o ter "'Voual use ettereseas' reuN. 11 met--asrad s' rcmmesewl sab" bonbulson. 10. MASS NOTIFICATION CONTROLS, APPLIANCES,AND CIRCUITS This system does not have an MNS. 10.1 MNS Local Operating Consoles Location 1: Location 2: Location 3: 10.2 High -Power Speaker Arrays Number of HPSA speaker initiation zones: Location 1: Location 2: Location 3: 103 Mass Notification Devices Combination fire alarm/MNS visible appliances: MNS-only visible appliances: Textual signs: Other (describe): Supervision class: 10.3.1 Special Hazard Notification This system does not have special suppression predischarge notification. MNS systems DO NOT override notification appliances required m provide special suppression predischarge notification. 11. TWO-WAY EMERGENCY COMMUNICATION SYSTEMS ILI Telephone System Number of telephone jacks installed: Number of telephone handsets stored on site: Type of telephone system installed: Electrically powered This system does not have a two-way telephone system. Number of warden stations installed: Sound powered III Two -Way, Radio Communications Enhancement System This system does not have a two-way radio communications enhancement system. Percentage of area covered by two-way radio service: Criticalarem: % General building areas: % Amplification component locations: Inbound signal strength: dB. Outbound signal strength: dBm Donor antenna isolation is: dB above the signal booster gain Radio frequencies covered: Radio system monimr panel location: COPYight®3e0914Merel Fire Fm.s NuneiM. Ttls ro- mar M c ad fw"IMivnualu W aim M reaek. sm,r �cVice W ee. r_l sek usiui N n If TWO-WAY EMERGENCY COMMUNICATION SYSTEMS (continued) 113 Area of Refuge of Rescue Assistance) Emergency Communications Systems This system does not have an area of refuge (area of rescue assistance) emergency communications system. Number of stations: Location of central control point Days and hours when central control point is attended: Location of alternate control point: Days and boors when altemate control point is attended: I14 Elevator Emergency Communications Systems This System does not have an elevator emergency communications system. Number of elevators with stations: Location of central control point Days and hours when central control point is attended: Location of alternate control point: Days and hours when alternate control point is attended: 115 Other Two -Way Communication Systems Describe: 12. CONTROL FUNCTIONS This system activates the following control functions: Hold -open door releasing devices Smoke management HVAC shutdown FIS dampers Door unlocking Elevator recall Fuel source shutdown Extinguishing agent release Elevator shunt Nip Mass notification system override of foe alarm notification appliances Other (specify): 12.1 Addressable Control Module. This system does not have control modules. Number of devices: Other (specify): 13. SYSTEM POWER 13.1 Control Unit 13.1.1 Primary Power Input voltage of control panel: 120 VAC Control panel amps: 20 Overcuuent protection: Type: BREAKER Amps: 20 Location(ofprimmy supply panel board): Front riser room Disconnecting means location: ELECTRICAL PANEL, MARKED ON PANELS 13.12 Eagine-Driven Generator This system does not have agenemon. Location ofgenemtor: Location of fuel storage: Type of fuel: Ggyr.. 2009 aetMal N. or.— g .s,n,lnla loom mayNwplely IMrvNcel uee olMr Ihan Mruak.Xmayroteecapiae prmmmacal caNwEn4ibullon. 13. SYSTEM POWER (continued) 13.13 Uninterruptible Power System This system does not have a UPS. Equipment powered by a UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode (hours): In alarm mode (minutes): 13.IA Batteries Location: IN PANEL Type: LEADACID Nominal voltage: 12 Amp/bour rating: 18 VDC X 2 Calculated capacity of batteries to drive the system: In standby mode (hours): 24 In alarm mode (minutes): 5 Batteries are marked with date of manufacture Battery calculations are attached 131 In -Building Fire Emergency Voice Alarm Communication System or Mass Notification System This system does not have an EVACS or MEVS system. 131.1 Primary Power Input voltage of EVACS or NB4S panel: EVACS or MNS panel amps: Overcurrent protection: Type: Amps: Location (of primary supply panel board): Disconnecting means location: 1311 Engine -Driven Generator This system does not have a generator. Location of generator: Location of fuel storage: Type of fuel: 131.3 Uninterruptble Power System This system does not have a UPS. Equipment powered by a UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected no it: In standby mode (hours): In alarm mode (minutes): 131A Batteries Location: Type: Nominal voltage: Amp/hour rating: Calculaed capacity of batteries to drive the system: In standby mode (hours): In alarm mode (minutes): Batteries are marked with date of manufacture Battery calculations are attached CoPOONO2Ca9 Net s Fin Prmegim PssO[N�im.ltiq fwm may. wpieoar IWNW81 use NMr Dien Mrmeb. It mryM pexpieG brmmmerciel axle MtlIaNWIM. 13. SYSTEM POWER (continued) 133 Notification Appliance Power Extender Panels This system does not have power extender panels. 133.1 Primary Power Input voltage of power extender panel(s): 120 VAC Power extender panel amps: 6 Overcurrent protection: Type: BREAKER Amps: 20 Location (of primary supply panel board): Fire Front Rill ROOM Disconnecting means location: ELECTRICAL PANEL, MARKED ON FIRE PANELS 1332 Engine -Driven Generator This system does not have agenerator. Location of generator: Location of fuel storage: Type of fuel: 133.3 Uninterruptible Power System This system does not have, UPS. Equipment powered by a UPS system: Location of UPS system: Calculated capacity of UPS batteries to drive the system components connected to it: In standby mode (hours): In alarm mode (minutes): 133.4 Batteries Location: IN PANEL Type: LEAD ACID Nominal voltage: 12 g Amp/hour rating: 18 VDC X 2 Calculated capacity of batteries to drive the system: In standby mode (boors): 24 In alarm mode (minutes): 5 Batteries are marked with date of manufacture Battery calculations are attached 14. RECORD OF SYSTEM INSTALLATION Fill out after all installation is complete and wiring has been checked for opens, shorts, ground fauhs, and improper branching, but before conducting operational acceptance tests. This is a: New system Modification to an existingsystem Permit number: The system has been installed in accordance with the following requirements: (Note any or all that apply.) NFPA 72, Edition: 2019 NFPA 70, Nat onol Electrical Code, Artir le 760, Edition: 2017 Manufacturer's published instructions Other(specify): System deviations from referenced NFPA standards: NONE Signed: Printed time: Trevor Blackburn Date: 4Sght Security LLC Organization: Title: JOURNEYMAN TECHNICIAN Phone: 208-861-3510 CsMght02ees Nafv FIre Pramctim Tamculm. lltls so me, W¢ .d ix IMWdN. un a1w,an,, o., it me, n,a a a wFeau, wmmaaa eae u eno-ite_ 15. RECORD OF SYSTEM OPERATIONAL ACCEPTANCE TEST Na. system All operational features and functions of this system were tested by, or m the presence of the signer shown below, on the date shown below, andwerefound to be operatingproperly in accordance with the requirements for the following' Modifications to an existing system -411 newly modified operational features and functions ofthe system were tested by, or in the presence of the signer shown below, on the date shown below, and were found to be operanngproperly in accordance with the requirements ofthe following' NFPA 72, Edition: 2017 NFPA 70, Nafioml Electrical Code, Antic le 760, Edition: 2017 Manufacturer's published instructions Other (specify): Individual device testing documentation [Inspection and Testing Form (Figure 14.6.2.4) is attached] Signed: Printed name: Trevor Blackburn Date: 4Sight Security LLC Organization: Title: JOURNEYMAN TECHNICIAN Phone: 208A81-3510 16. CERTIFICATIONS AND APPROVALS 16.1 System Installation Contractor: This system, as specified herein, has been installed and tested according to all NFPA standards cited herein. Signed: Printed name: Trevor Blackburn Date: 4Sight Security LLC Organization: Tile: JOURNEYMAN TECHNICIAN Phone: 208.887J570 16.2 System Service Contramr: The undersigned has a service contract for this system in effect as of the data show. below. Signed: Printed name: Trevor Blackburn 4Sight Security LLC Organization: Title: JOURNEYMAN TECHNICIAN 163 Supervising Station: This system, as specified herein, will be monitored according to all NFPA standards cited herein. Signed: 4Sight Security LLC Printed time: JASON PERRON Organization: Title: JOURNEYMAN TECHNICIAN Data Phone: 208-881-3510 Date: Phone: 208-881-3510 coragisOmce Nalvsal Fire Plol.dscb Wl mp mml maY is� ow.a ruff maws. u..--I1b —I-, nmw na be Wpi¢a lo�vmmemiBl..lea EIeNWIIm. 16. CERTIFICATIONS AND APPROVALS (continued) 16A Property or Owner Representative: I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein. Signed: Printed name: Date: Organiaetion: Title: Phone: 16.5 Authority Having Jurisdiction: I have witnessed a satisfactory acceptance test of this system and find it to be installed and operating properly in accordance with its approved plans and specifications, with its approved sequence of operations, and with all NFPA standards cited herein. Signed: N` ,4 Printed name: 6 4�� 1 Date: 9/J 1 /* gan Ori.tion: cr.lyof �bt.�W[ � Title: VP� 1 T;w&cJI bI- Phone: CapyrlaMOM]9 Nalunel FIB PrdeG'pn AnaWiaOon. Thlsrdm may to wpieObr YdiviEualum alMrlM1anWReale.l�mrynd be ¢pNE lw xrtimertlel felea EbpiW11M.