ARCHITECTURAL CHANGES - 23-00732 - Good 2 Go - New Commercial Bldg
ARCHITECTURAL SUPPLEMENTARY INSTRUCTIONS Date:Dec 21,2023 ASI Number:#1 Owner changes Project Number:#22007 Project:Good 2 Go 104 Rexburg ID Client:Brad Hall &Associates The c hanges d escribed i n t his architectural supplementary instructions s hall modify t he o riginal Bid Documents d ated 10/11/23 a s noted below f or t he a bove r eferenced p roject.I nfor mation i ncluded in t his ASI s hall s upersede a ll p revious drawings a nd i nfor mation r elated t o the p roject. Acknowledge r eceipt o f t his ASI i n t he s pace provided o n t he Bid F or m.F ailure to do so may subject t he Bidder t o d isqualification. Original Sheet #Instructions: G-101 -Updated code analysis based upon increased size -Updated Occupant Load Schedule AS-101 -Location of the Trash Enclosure was shifted to the Southeast corner of the site. -Building grew to the west for larger Rusty Taco -Relabeled Tenant Suite 200 and Tenant Suite 300 AS-102 -Updated detail 1/AS-102 for Trash Enclosure size and location. -Re-organized details on sheet. FC-103 -Updated Fuel Canopy dimensions to match provided fuel canopy drawings -Updated Detail 2 &3 /FC-103 to add the roof drains per client request A-100 -Addition of a shaft in Kitchen 202,positioned between Grid E and Grid 1,to accommodate the anticipated roof drain. -Relocated the mop sink in Janitor Room 113 to the opposite corner of the room. -Moved the water heater to the opposite side of the room,positioning it above a new platform with a height of 7’-8”inches. -Addition of shaft in kitchen 104 positioned between Grid B and Grid 1, to accommodate the anticipated roof drain. 305 1ST STREET ▪IDAHO FALLS,ID 83401 ▪208.757.5700 ▪RESINARCHITECTURE.COM Page 1 of 2 A-104 -Updated the dimensions of the new platfor m for the water heater in the Janitor room to measure 3’-6”by 5’-0”. -Extended the length of the TI 200 building to 40’-10”,as per the owner's request. -Added the dimensions for the new shaft located in Grid E -Added the dimensions for the new shaft located in Grid B A-150 -Added a platform with a height of 7’-8”to support the water heater. -Updated Ceiling height is Open above in the Janitor Room. -Updated the light fixture dimensions to be 1.3’x3.8’ A-201 -Updated sliding walk up window to be 4’x4’for the TI 200 -Added control joints on the east and west sides of the building for enhanced stucco durability. -Added an additional control joint to the extended area of the building. -Showing downspout nozzles 2/A-201 for back up roof drains. A-401 -Added two interior elevations of the Janitor Room with a new platfor m for the water heater. A-403 -Updated the placement of equipment and furniture (FS25,FS23,FS24, FS22 and M30 to accommodate the roof drain shaft. A-521 -Added detail 4/A-521 for the new platfor m for the water heater.Bottom of joist to be at 6’-7”. Proposal Request It is anticipated that changes described in the document may result in an ADD/DEDUCT to the contract.Contractor shall submit documentation clarifying the amount of change to be considered as part of a change in contract. 305 1ST STREET ▪IDAHO FALLS,ID 83401 ▪208.757.5700 ▪RESINARCHITECTURE.COM Page 2 of 2 ID DATE DESCRIPTION 0002 10/11/23 12/21/23 Issue for AHJ Review ASI #1 Owner Changes STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL G-101 CIVIL 305 1st STREET, IDAHO FALLS,ID 83401 PH: 208.757.5700 22007 GOOD 2 GO 104 - REXBURG ID 1055 S 12th W REXBURG, ID 83440 FROST STRUCTURAL ENGINEERING 1020 LINCOLN RD IDAHO FALLS, ID 83401 PHONE: (208) 227-8404 Original document is on file with the date and architect signature Original documents signed by: 12/21/23 Date original documents signed: MUSGROVE ENGINEERING, P.A. 645 W. 25TH ST. IDAHO FALLS, ID 83402 PHONE: (208) 523-2862 THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. JONATHAN GALLUP MUSGROVE ENGINEERING 234 S. WHISPERWOOD WAY BOISE, ID 83709 PHONE: (208) 384-0585 CONNECT ENGINEERING 1150 HOLLIPARK DRIVE IDAHO FALLS, ID 83401 PHONE: (208) 681-8590 FIRST FLOOR LIFE SAFETY PRELIMINARY FOR REVIEW NOT FOR CONSTRUCTION Code Analysis Summary - G2G 104 Rexburg ID Building Codes:2018 International Building Code 2018 International Mechanical Code Authority Having Jurisdiction:2018 International Energy Conservation Code City of Rexburg 2017 Idaho Plumbing Code 2017 National Electrical Code (NEC) 2018 International Fire Code Property Address and Parcel Number TBD, Rexburg, ID 83440 RPRXBCA0365406 Building Occupancy Classification and Use Designation MIxed Use Building Story Use (Chapter 3)Mercantile proposed 1 M Business proposed 1 B Business proposed 1 B 303.1.1 Small buildings and tenant spaces A building or tenant space used for assembly purposes with an occupant load of less than 50 persons shall be classified as a Group B occupancy. 406.7 Motor fuel-dispensing facilities Motor fuel-dispensing facilities shall comply with the International Fire Code and Sections 406.7.1 and 406.7.2. 406.7.1 Vehicle Fueling Pad The vehicle shall be fueled on noncoated concrete or other approved paving material having a resistance not exceeding 1 megohm as determined by the methodology in EN 1081. 406.7.2 Canopies Canopies under which fuels are dispensed shall have a clear, unobstructed height of not less than 13 feet 6 inches (4115 mm) to the lowest projecting element in the vehicle drive-through area. Canopies and their supports over pumps shall be of noncombustible materials, fire-retardant-treated wood complying with Chapter 23, wood of Type IV sizes or of construction providing 1-hour fire resistance. Combustible materials used in or on a canopy shall comply with one of the following: 1. Shielded from the pumps by a noncombustible element of the canopy, or wood of Type IV sizes; 2. Plastics covered by aluminum facing having a thickness of not less than 0.010 inch (0.30 mm) or corrosion-resistant steel having a base metal thickness of not less than 0.016 inch (0.41 mm). The plastic shall have a flame spread index of 25 or less and a smoke-developed index of 450 or less when tested in the form intended for use in accordance with ASTM E84 or UL 723 and a self-ignition temperature of 650°F (343° C) or greater when tested in accordance with ASTM D1929; or 3. Panels constructed of light-transmitting plastic materials shall be permitted to be installed in canopies erected over motor vehicle fuel-dispensing station fuel dispensers, provided the panels are located not less than 10 feet (3048 mm) from any building on the same lot and face yards or streets not less than 40 feet (12 192 mm) in width on the other sides. The aggregate areas of plastics shall be not greater than 1,000 square feet (93 m2). The maximum area of any individual panel shall be not greater than 100 square feet (9.3 m2). Building Height and Area Proposed Actual Allowed by IBC Construction Type (601)VB Non-Sprinklered Allowable Building Height In Feet Above Grade Plane (Table 504.3):27'-0"40'-0"Okay Allowable Number of Stories Above Grade Plane (Table 504.4):1 1 Okay Allowable Area Factor (Table 506.2):8,293 9,000 Okay Mercantile 5,285 Business 2,176 Business 831 Required Occupancy Separation (Table 508.4)Proposed Required Mixed Use Occupancies M / B Non-Sprinklered 0h 0h Okay Fire-Resistance Rating Requirements for Building Elements (Hours) (Table 601) Construction Type VB Primary Structural Frame:0 Hour Okay Bearing Walls, Exterior:0 Hour Okay Bearing Walls, Interior:0 Hour Okay Nonbearing Walls:0 Hour Okay Floor Construction and associated secondary structural members:0 Hour Okay Roof Construction and associated secondary structural members:0 Hour Okay Fire-Resistance Rating Req. for Ext. Walls Based on Fire Separation Distance (Table 602) Exterior Walls:X >/= 30 0 Hour Fire-Resistance Rated Construction Opening Protectives (Section 716)None Required Okay Fire Walls (Section 706)None Required Okay Fire Barriers (Section 707, Table 508.4)None Required Okay Fire Partitions (Section 708, 420.2, 1018.1)None Required Okay Smoke Barriers (Section 709)None Required Okay Shaft Enclosures (Section 713)None Required Okay Table 803.11 - INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY Interior exit stairways and ramps and exit passageways Corridors and enclosure for exit access stairways and ramps Rooms and enclosed spaces Group B & M A B C Class A = Flame spread index 0-25; smoke-developed index 0-450. Class B = Flame spread index 26-75; smoke-developed index 0-450. Class C = Flame spread index 76-200; smoke-developed index 0-450. Fire Protection Systems Automatic Sprinkler Systems:None Required Okay Portable Fire Extinguishers(906):75' Max Every 75'Okay Fire Alarm and Detection System (907.2):None Required Okay Occupant Load (Table 1004.5)See Occupant Load Chart on Sheet G-101 5/31/23 - approximately 93 total Occupants Egress Capacity Required Provided Other Egress (.2”/occupant):Section 1005.3.2 32" 2 @ 72" Ea. & 2 @ 48" Ea.Okay Number of Exits Required 1 Each Side / Tenant 2 Each Side / Tenant Okay Table 1017.2: Exit Access Travel Distance 200' Max.Okay Plumbing Fixtures Required (Table 2902.1) Mercantile Occupancy 1 per #Required Provided W.C.'s 500 1 13 Okay Urinals -0 5 Okay Lavatories 750 1 8 Okay Drinking Fountain 1000 1 0 Providing Water at Sink and at Soda Fountain Machines Okay Service Sink -1 2 Okay Business Occupancy - Future Tenant Improvement 200 1 per #Required Provided W.C.'s 25 2 0 Urinals -0 0 Lavatories 40 2 0 Drinking Fountain 100 1 0 Providing Water at Soda Fountain Machines Service Sink -1 0 see future tenant improvement plans Business Occupancy - Future Tenant Improvement 300 1 per #Required Provided W.C.'s 25 2 0 Urinals -0 0 Lavatories 40 2 0 Drinking Fountain 100 1 0 Providing Water at Soda Fountain Machines Service Sink -1 0 see future tenant improvement plans Combined Occupancy Uses Totals W.C.'s -3 13 Okay Urinals -0 5 Okay Lavatories -3 8 Okay Drinking Fountain -1 0 Providing Water at Soda Fountain Machines & Sink Okay Service Sink -2 2 Okay 2303.2 Emergency Disconnect Switches An approved emergency disconnect switch shall be provided at an approved location to stop the transfer of fuel to the fuel dispensers in the event of a fuel spill or other emergency. The emergency disconnect switch for exterior fuel dispensers shall be provided with ready access and shall be located within 100 feet (30 480 mm) of, but not less than 20 feet (6096 mm) from, the fuel dispensers. For interior fuel-dispensing operations, the emergency disconnect switch shall be provided with ready access and be installed at an approvedlocation. Such devices shall be distinctly labeled as: EMERGENCY FUEL SHUTOFF. Signs shall be provided in approved locations.Okay Code Analysis Summary - G2G 104 Rexburg IDBuilding Codes:2018 International Building Code2018 International Mechanical CodeAuthority Having Jurisdiction:2018 International Energy Conservation CodeCity of Rexburg 2017 Idaho Plumbing Code2017 National Electrical Code (NEC)2018 International Fire CodeProperty Address and Parcel NumberTBD, Rexburg, ID 83440RPRXBCA0365406Building Occupancy Classification and Use DesignationMIxed Use Building StoryUse (Chapter 3)Mercantile proposed 1 MBusinessproposed1BBusinessproposed1B303.1.1 Small buildings and tenant spacesA building or tenant space used for assembly purposes with an occupant load of less than 50 persons shall be classified as a Group B occupancy. 406.7 Motor fuel-dispensing facilities Motor fuel-dispensing facilities shall comply with the International Fire Code and Sections 406.7.1 and 406.7.2. 406.7.1 Vehicle Fueling Pad The vehicle shall be fueled on noncoated concrete or other approved paving material having a resistance not exceeding 1 megohm as determined by the methodology in EN 1081. 406.7.2 Canopies Canopies under which fuels are dispensed shall have a clear, unobstructed height of not less than 13 feet 6 inches (4115 mm) to the lowest projecting element in the vehicle drive-through area. Canopies and their supports over pumps shall be of noncombustible materials, fire-retardant-treated wood complying with Chapter 23, wood of Type IV sizes or of construction providing 1-hour fire resistance. Combustible materials used in or on a canopy shall comply with one of the following: 1. Shielded from the pumps by a noncombustible element of the canopy, or wood of Type IV sizes; 2. Plastics covered by aluminum facing having a thickness of not less than 0.010 inch (0.30 mm) or corrosion-resistant steel having a base metal thickness of not less than 0.016 inch (0.41 mm). The plastic shall have a flame spread index of 25 or less and a smoke-developed index of 450 or less when tested in the form intended for use in accordance with ASTM E84 or UL 723 and a self-ignition temperature of 650°F (343° C) or greater when tested in accordance with ASTM D1929; or 3. Panels constructed of light-transmitting plastic materials shall be permitted to be installed in canopies erected over motor vehicle fuel-dispensing station fuel dispensers, provided the panels are located not less than 10 feet (3048 mm) from any building on the same lot and face yards or streets not less than 40 feet (12 192 mm) in width on the other sides. The aggregate areas of plastics shall be not greater than 1,000 square feet (93 m2). The maximum area of any individual panel shall be not greater than 100 square feet (9.3 m2). Building Height and Area Proposed Actual Allowed by IBC Construction Type (601)VB Non-Sprinklered Allowable Building Height In Feet Above Grade Plane (Table 504.3):27'-0"40'-0"Okay Allowable Number of Stories Above Grade Plane (Table 504.4):1 1 Okay Allowable Area Factor (Table 506.2):8,293 9,000 Okay Mercantile 5,285 Business 2,176 Business 831 Required Occupancy Separation (Table 508.4)Proposed Required Mixed Use Occupancies M / B Non-Sprinklered 0h 0h Okay Fire-Resistance Rating Requirements for Building Elements (Hours) (Table 601) Construction Type VB Primary Structural Frame:0 Hour Okay Bearing Walls, Exterior:0 Hour Okay Bearing Walls, Interior:0 Hour Okay Nonbearing Walls:0 Hour Okay Floor Construction and associated secondary structural members:0 Hour Okay Roof Construction and associated secondary structural members:0 Hour Okay Fire-Resistance Rating Req. for Ext. Walls Based on Fire Separation Distance (Table 602) Exterior Walls:X >/= 30 0 Hour Fire-Resistance Rated Construction Opening Protectives (Section 716)None Required Okay Fire Walls (Section 706)None Required Okay Fire Barriers (Section 707, Table 508.4)None Required Okay Fire Partitions (Section 708, 420.2, 1018.1)None Required Okay Smoke Barriers (Section 709)None Required Okay Shaft Enclosures (Section 713)None Required Okay Table 803.11 - INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY Interior exit stairways and ramps and exit passageways Corridors and enclosure for exit access stairways and ramps Rooms and enclosed spaces Group B & M A B C Class A = Flame spread index 0-25; smoke-developed index 0-450. Class B = Flame spread index 26-75; smoke-developed index 0-450. Class C = Flame spread index 76-200; smoke-developed index 0-450. Fire Protection Systems Automatic Sprinkler Systems:None Required Okay Portable Fire Extinguishers(906):75' Max Every 75'Okay Fire Alarm and Detection System (907.2):None Required Okay Occupant Load (Table 1004.5)See Occupant Load Chart on Sheet G-101 5/31/23 - approximately 93 total Occupants Egress Capacity Required Provided Other Egress (.2”/occupant):Section 1005.3.2 32" 2 @ 72" Ea. & 2 @ 48" Ea.Okay Number of Exits Required 1 Each Side / Tenant 2 Each Side / Tenant Okay Table 1017.2: Exit Access Travel Distance 200' Max.Okay Plumbing Fixtures Required (Table 2902.1) Mercantile Occupancy 1 per #Required Provided W.C.'s 500 1 13 Okay Urinals -0 5 Okay Lavatories 750 1 8 Okay Drinking Fountain 1000 1 0 Providing Water at Sink and at Soda Fountain Machines Okay Service Sink -1 2 Okay Business Occupancy - Future Tenant Improvement 200 1 per #Required Provided W.C.'s 25 2 0 Urinals -0 0 Lavatories 40 2 0 Drinking Fountain 100 1 0 Providing Water at Soda Fountain Machines Service Sink -1 0 see future tenant improvement plans Business Occupancy - Future Tenant Improvement 300 1 per #Required Provided W.C.'s 25 2 0 Urinals -0 0 Lavatories 40 2 0 Drinking Fountain 100 1 0 Providing Water at Soda Fountain Machines Service Sink -1 0 see future tenant improvement plans Combined Occupancy Uses Totals W.C.'s -3 13 Okay Urinals -0 5 Okay Lavatories -3 8 Okay Drinking Fountain -1 0 Providing Water at Soda Fountain Machines & Sink Okay Service Sink -2 2 Okay 2303.2 Emergency Disconnect Switches An approved emergency disconnect switch shall be provided at an approved location to stop the transfer of fuel to the fuel dispensers in the event of a fuel spill or other emergency. The emergency disconnect switch for exterior fuel dispensers shall be provided with ready access and shall be located within 100 feet (30 480 mm) of, but not less than 20 feet (6096 mm) from, the fuel dispensers. For interior fuel-dispensing operations, the emergency disconnect switch shall be provided with ready access and be installed at an approvedlocation. Such devices shall be distinctly labeled as: EMERGENCY FUEL SHUTOFF. Signs shall be provided in approved locations.Okay MECH. RM 102 46 SF 300 1 4' os SPACE NAME / FUNCTIONAL USE ROOM NUMBER AREA OF ROOM / SPACE OCCUPANT LOAD FACTOR CALCULATED OCCUPANCY TRANSITION POINT FOR COMMON PATH OF EGRESS TRAVEL DISTANCE EGRESS PATH PORTABLE FIRE EXTINGUISHER AND CABINET EXIT SIGN OR DIRECTIONAL EXIT SIGN PER PLANS LIFE SAFET Y PL AN LEGEND ZONE TAG SWITCH W/ OCCUPANCY SENSOR MINIMUM CLEAR SPACE/ADA ACCESSIBLILITY CLEARANCE LIFE SAFET Y GENERAL NOTES A. SEE "G" SERIES SHEETS FOR ACCESSIBILITY COMPLIANCE DETAILS PERTAINING TO DOOR SWING CLEARANCES, DRINKING FOUNTAIN AND SINK CLEAR SPACE REQUIREMENTS, ACCESSIBLE SIGNAGE, FLOOR TRANSITION DETAILS, ACCESSIBLE MOUNTING HEIGHTS, TOILET, SHOWER AND TUB REQUIREMENTS. RECESSED FIRE EXTINGUISHER 831 sq ft 5,285 sq ft 22 11 B B D D C C 33 F E E 70' 55' 25' 42' 68' A A 2,176 sq ft A6 A2 A21 A21 A2A2 E5 E5 E5 E5 A1 48' 44' FREEZER 109 100 SF 300 1 BEER 108 168 SF 300 1 DISPLAY/PALLET 107 164 SF 60 3 ELEC. 106 99 SF 300 1 PACKAGE BEV 105 344 SF 300 2 VESTIBULE 100 112 SF 0 0 JAN. 113 33 SF 300 1 WOMEN 112 404 SF 0 0 MEN 111 386 SF 0 0 OFFICE 103 58 SF 150 1 KITCHEN 104 527 SF 200 3 C-STORE 102 1,899 SF 60 32 CIRCULATION 110 331 SF 0 0 CIRCULATION 200 233 SF 0 0 DINING 201 563 SF 15 38 KITCHEN 202 1,299 SF 200 7 POS 101 201 SF 60 4 CIRCULATION 300 130 SF 0 0 KITCHEN 301 641 SF 200 4 LIFE SAFETY PLAN KEYNOTES A1 A2 A6 A21 A37 E5 RECESSED EMERGENCY KEY BOX WALL MOUNTED FIRE EXTINGUISHER RECESSED FIRE EXTINGUISHER EXIT SIGN OR DIRECTIONAL EXIT SIGN PER PLANS, PROVIDE POWER - SEE ELECTRICAL DOOR OPERATION SWITCH - SEE ELECTRICAL EMERGENCY FUEL SHUT OFF BUTTON - SEE ELECTRICAL PROJECT NARRATIVE NEW CONSTRUCTION FOR A NEW GROUND UP CONVENIENCE STORE WITH A FUEL ISLAND CANOPY. THE C-STORE WILL CONSIST OF A NEW CORE AND SHELL BUILDING THAT IS MASTER PLANNED TO HAVE (2) TWO ADDITIONAL TENANTS. THE TENANT SPACES ARE BOTH NOT PART OF THIS PLAN REVIEW. THEY WILL BE A FUTURE SEPARATE PLAN REVIEW FOR EACH INDIVIDUAL SPACE. ONE OF THE TENANT SPACES WILL HAVE A DEDICATED DRIVE THRU AND THE OTHER WILL NOT. THE OVERALL CORE BUILDING HAS BEEN MASTER PLANNED TO ACCOMMODATE THESE FUTURE SPACES SUCH AS DESIGNING THE GREASE INTERCEPTOR TO ALLOW FOR KITCHEN SPACES IN ALL THREE TENANTS, ETC. UTILITIES WILL BE STUBBED UP INTO EACH TENANT SPACE AS PART OF THIS CORE AND SHELL PLAN, HOWEVER NO FLOOR SLAB IS PLANNED TO BE POURED TO ALLOW FOR GREATER FUTURE FLEXIBILITY DEPENDING UPON WHAT TENANTS DECIDE TO OCCUPY THESE SPACES. OCCUPANCY & OCCUPANT LOAD SCHEDULE TENANT TENANT 100 TENANT 200 TENANT 300 OCCUPANCY M Mercantile M Mercantile M Mercantile M Mercantile M Mercantile M Mercantile M Mercantile M Mercantile M Mercantile M Mercantile M Mercantile M Mercantile M Mercantile M Mercantile M Mercantile B Business B Business B Business B Business B Business ZONE NUMBER 100 101 102 103 104 105 106 107 108 109 110 111 112 113 301 200 201 202 300 301 ZONE NAME VESTIBULE POS C-STORE OFFICE KITCHEN PACKAGE BEV ELEC. DISPLAY/PALLET BEER FREEZER CIRCULATION MEN WOMEN JAN. ATTIC ACCESS CIRCULATION DINING KITCHEN CIRCULATION KITCHEN MEASURED AREA 112.42 200.52 1,898.53 57.82 527.19 343.72 98.59 163.58 167.99 99.97 331.14 385.97 404.31 33.48 152.85 4,978.08 ft² 233.24 563.44 1,298.96 2,095.64 ft² 129.75 640.67 770.42 ft² 7,844.14 ft² SPACE FUNCTION Circulation Mercantile Mercantile Business Kitchens, commercial Accessory storage areas, mechanical equipment room Accessory storage areas, mechanical equipment room Mercantile Accessory storage areas, mechanical equipment room Accessory storage areas, mechanical equipment room Circulation Restrooms Restrooms Accessory storage areas, mechanical equipment room Mercantile Circulation Assembly without fixed seats Unconcentrated (tables and chairs) Kitchens, commercial Circulation Kitchens, commercial LOAD FACTOR 0 60 60 150 200 300 300 60 300 300 0 0 0 300 60 0 15 200 0 200 OCCUPANTS 0 4 32 1 3 2 1 3 1 1 0 0 0 1 3 52 0 38 7 45 0 4 4 101 02 02 SCALE: 3/32" = 1'-0" 1 FIRST FLOOR LIFE SAFETY PLAN 12/21/2023 ID DATE DESCRIPTION 000102 10/11/23 10/23/23 12/21/23 Issue for AHJ Review Response to AHJ ASI #1 Owner Changes STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL AS-101 CIVIL 305 1st STREET, IDAHO FALLS,ID 83401 PH: 208.757.5700 22007 GOOD 2 GO 104 - REXBURG ID 1055 S 12th W REXBURG, ID 83440 FROST STRUCTURAL ENGINEERING 1020 LINCOLN RD IDAHO FALLS, ID 83401 PHONE: (208) 227-8404 Original document is on file with the date and architect signature Original documents signed by: 12/21/23 Date original documents signed: MUSGROVE ENGINEERING, P.A. 645 W. 25TH ST. IDAHO FALLS, ID 83402 PHONE: (208) 523-2862 THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. JONATHAN GALLUP MUSGROVE ENGINEERING 234 S. WHISPERWOOD WAY BOISE, ID 83709 PHONE: (208) 384-0585 CONNECT ENGINEERING 1150 HOLLIPARK DRIVE IDAHO FALLS, ID 83401 PHONE: (208) 681-8590 ARCHITECTURAL SITE PLAN PRELIMINARY FOR REVIEW NOT FOR CONSTRUCTION SITE PL AN GENERAL NOTES A. FOR UTILITIES, GRADING AND DRAINAGE SITE SEE CIVIL PLANS. SITE PL AN LEGEND LANDSCAPE AREA - SEE LANDSCAPE PLANS CONCRETE - SEE CIVIL ASPHALT - SEE CIVIL GRAVEL - SEE CIVIL PROPERTY LINE SETBACKS EASEMENTS OVERHEAD POWER UNDERGROUND POWER STORM DRAIN SANITARY SEWAR WATER COMPRESSED AIR CENTER LINE ARCHITECTURAL SITE PLAN KEYNOTES A1 A8 A9 A14 A30 A32 A36 A37 C1 E1 E3 E4 E5 E7 E8 E10 E11 E14 M20 M21 M22 M24 P6 P12 P15 P17 Q4 Q5 <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> 26 00 00 Electrical 26 00 00 Electrical 26 00 00 Electrical 26 00 00 Electrical 26 00 00 Electrical 26 00 00 Electrical <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> 22 00 00 Plumbing <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> RECESSED EMERGENCY KEY BOX DUMPSTER GAS TANK FIRE HYDRANT BOLLARD GREASE INTERCEPTOR - SEE PLUMBING SHELF, PROVIDE BLOCKING - O.F.O.I DOOR OPERATION SWITCH - SEE ELECTRICAL CURB AND GUTTER - SEE CIVIL PLANS ELECTRICAL METER, SEE ELECTRICAL TRANSFORMER SWITCHBOARD EMERGENCY FUEL SHUTOFF PUMP EMERGENCY FUEL SHUT OFF BUTTON - SEE ELECTRICAL STREET LAMP PYLON SIGN DESIGNED BY OTHERS - PROVIDE POWER - SEE ELECTRICAL HIGHWAY HI-RISE SIGN, DESIGN BY OTHERS- PROVIDE POWER AND DATA SIGN - PROVIDE CONDUIT, POWER AND DATA FOR FUTURE SIGN TRANSFORMER - SEE ELECTRICAL ICE MERCHANDISER FIREWOOD DISPLAY PROPANE CAGE EXTERIOR STORAGE RACK GAS METER, SEE PLUMBING PLANS DOWNSPOT NOZZLE - SEE PLUMBING HOSEBIBB- SEE PLUMBING WATER METER - SEE PLUMBING DEF REMOTE FILL CONTAINER TIRE FILLING AIR STTION. O.F.O.I. - PROVIDE ELECTRICAL SEE ELECTRICAL 6 1211 1 25 24 23 22 21 20 19 18 17 41 40 39 38 37 36 35 34 33 32 31 30 29 N J J 2 3 4 5 7 8 9 10 13 14 15 16 5 AS-102 2 FC-102 1 FC-103 -0.000' 153.625' 60' E8 E7 E10 P15 E5 A1 E5 UNIVERSITY BLVD. MC CULLOCH RD. 2 AS-102 6 AS-102 4 AS-102 FF:4852.30 SEE CIVIL 53' 8,293 sq ft A8 A8 A14 E7 E7 E7 E7 E3 P6P6 E1 A4 E7 C1 C1 C1 E11 A32P17P17 E14 A30A30A30 P12 P12 Tenant 200 Tenant 300 BUILDING FOOTPRINT 02 02 02 SCALE: 1" = 30'1 ARCHITECTURAL SITE PLAN 12/21/2023 ID DATE DESCRIPTION 0002 10/11/23 12/21/23 Issue for AHJ Review ASI #1 Owner Changes STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL AS-102 CIVIL 305 1st STREET, IDAHO FALLS,ID 83401 PH: 208.757.5700 22007 GOOD 2 GO 104 - REXBURG ID 1055 S 12th W REXBURG, ID 83440 FROST STRUCTURAL ENGINEERING 1020 LINCOLN RD IDAHO FALLS, ID 83401 PHONE: (208) 227-8404 Original document is on file with the date and architect signature Original documents signed by: 12/21/23 Date original documents signed: MUSGROVE ENGINEERING, P.A. 645 W. 25TH ST. IDAHO FALLS, ID 83402 PHONE: (208) 523-2862 THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. JONATHAN GALLUP MUSGROVE ENGINEERING 234 S. WHISPERWOOD WAY BOISE, ID 83709 PHONE: (208) 384-0585 CONNECT ENGINEERING 1150 HOLLIPARK DRIVE IDAHO FALLS, ID 83401 PHONE: (208) 681-8590 ENLARGED SITE PLAN PRELIMINARY FOR REVIEW NOT FOR CONSTRUCTION SITE PL AN GENERAL NOTESA. FOR UTILITIES, GRADING AND DRAINAGE SITE SEE CIVIL PLANS. SITE PL AN LEGEND LANDSCAPE AREA - SEE LANDSCAPE PLANS CONCRETE - SEE CIVIL ASPHALT - SEE CIVIL GRAVEL - SEE CIVIL PROPERTY LINE SETBACKS EASEMENTS OVERHEAD POWER UNDERGROUND POWER STORM DRAIN SANITARY SEWAR WATER COMPRESSED AIR CENTER LINE ARCHITECTURAL SITE PLAN KEYNOTES A1 A8 A9 A14 A30 A32 A36 A37 C1 E1 E3 E4 E5 E7 E8 E10 E11 E14 M20 M21 M22 M24 P6 P12 P15 P17 Q4 Q5 <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> 26 00 00 Electrical 26 00 00 Electrical 26 00 00 Electrical 26 00 00 Electrical 26 00 00 Electrical 26 00 00 Electrical <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> 22 00 00 Plumbing <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> RECESSED EMERGENCY KEY BOX DUMPSTER GAS TANK FIRE HYDRANT BOLLARD GREASE INTERCEPTOR - SEE PLUMBING SHELF, PROVIDE BLOCKING - O.F.O.I DOOR OPERATION SWITCH - SEE ELECTRICAL CURB AND GUTTER - SEE CIVIL PLANS ELECTRICAL METER, SEE ELECTRICAL TRANSFORMER SWITCHBOARD EMERGENCY FUEL SHUTOFF PUMP EMERGENCY FUEL SHUT OFF BUTTON - SEE ELECTRICAL STREET LAMP PYLON SIGN DESIGNED BY OTHERS - PROVIDE POWER - SEE ELECTRICAL HIGHWAY HI-RISE SIGN, DESIGN BY OTHERS- PROVIDE POWER AND DATA SIGN - PROVIDE CONDUIT, POWER AND DATA FOR FUTURE SIGN TRANSFORMER - SEE ELECTRICAL ICE MERCHANDISER FIREWOOD DISPLAY PROPANE CAGE EXTERIOR STORAGE RACK GAS METER, SEE PLUMBING PLANS DOWNSPOT NOZZLE - SEE PLUMBING HOSEBIBB- SEE PLUMBING WATER METER - SEE PLUMBING DEF REMOTE FILL CONTAINER TIRE FILLING AIR STTION. O.F.O.I. - PROVIDE ELECTRICAL SEE ELECTRICAL 2 AS-103 11 AS-102 6" 1'-4" 6" 25'-4" A30A30 1 AS-103 1'-4" 10'-8" 1'-4" 8'-0" 12'-0" 12'-0" 12'-0" A8 A8 3 3 AS-102 7'-6" 2'-6" 3'-0" 2'-0" 6"1'-8" 3'-4" 5'-0" A30 6" 6" 6" E4 A30 Q5 P16 A30 3'-6" 1'-0" 7" SHUT OFF VALVE EMERGENCY FUEL SHUT OFF PUSH SIGN 6"X6" HSS STEEL TUBING 6"X6" STEEL TUBING, POWDER COATED 05 05 13 10"X10" STEEL PLATE BOLTED DOWN WITH ANCHOR BOLTS, PLATE POWDER COATED 05 05 13 4'-0" 3'-4" A30 A30 Q4 3 AS-103PRECAST WALL CAP EXPANSION JOINT @ COLUMNS reference detail, TYP. WALL ASSEMBLY 0'-8" Masonry - Structural Undefined COLUMN ASSEMBLY 1'-6" Masonry - Split Face 04 20 00 Unit Masonry SPLIT FACE CMU WITH 50% OF SPLIT FACE FACING OUT AND 50% OF SPLIT FACE FACING IN, RANDOM MIX TO BE PROPOSED BY MASON 2'-6" 2'-4" E.Q.E.Q. E.Q. E.Q. S-11 E4 02 SCALE: 1/8" = 1'-0"6 TRASH ENCLOSURE SCALE: 1/8" = 1'-0"2 PAD AT SHUT OFF SCALE: 1/2" = 1'-0"3 EMERGENCY SHUT OFF SCALE: 1/4" = 1'-0"5 DEF FILL STATION SCALE: 1/2" = 1'-0"1 DUMPSTER ELEVATION SCALE: 1/4" = 1'-0" 4 FUEL SHUT OFF CONCRETE PAD 12/21/2023 ID DATE DESCRIPTION 0002 10/11/23 12/21/23 Issue for AHJ Review ASI #1 Owner Changes STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL FC-103 CIVIL 305 1st STREET, IDAHO FALLS,ID 83401 PH: 208.757.5700 22007 GOOD 2 GO 104 - REXBURG ID 1055 S 12th W REXBURG, ID 83440 FROST STRUCTURAL ENGINEERING 1020 LINCOLN RD IDAHO FALLS, ID 83401 PHONE: (208) 227-8404 Original document is on file with the date and architect signature Original documents signed by: 12/21/23 Date original documents signed: MUSGROVE ENGINEERING, P.A. 645 W. 25TH ST. IDAHO FALLS, ID 83402 PHONE: (208) 523-2862 THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. JONATHAN GALLUP MUSGROVE ENGINEERING 234 S. WHISPERWOOD WAY BOISE, ID 83709 PHONE: (208) 384-0585 CONNECT ENGINEERING 1150 HOLLIPARK DRIVE IDAHO FALLS, ID 83401 PHONE: (208) 681-8590 FUEL CANOPY DETAILS PRELIMINARY FOR REVIEW NOT FOR CONSTRUCTION 2 FC-103 2 FC-103 5'-0"138'-0"5'-0" 148'-0" 8'-3" 9'-8" 9'-8" 9'-6" 9'-8" 9'-8" 3'-3" 5'-0" 59'-8" 5'-0" 64'-8" 27'-6" 11'-0"29'-0"29'-0"29'-0"11'-0"29'-0" 24'-5 17/64" 15'-0" 3 FC-103 7'-6"SQR SEE CANOPY 16'-0" CLEARANCE 2'-6" 2'-6" 7'-6"SQR SEE CANOPY 2'-6" 2'-6" 6" 4'-0" 3'-0" MIN. REINFORCING BAR DESIGN AND FOOTING DESIGN - SEE DEFERRED SUBMITALS ANCHOR BOLT BY CANOPY SOLID GROUT POSITIVE SLOPE AWAY FROM BOLLARD NOTE: BASIS OF DESIGN ONLY - SEE DEFERRED SUBMITALS FOR CANOPY AND CANOPY FOOTING DESIGN. STEEL CANOPY COLUMN - SEE CANOPY DESIGN BY OTHERS ROOF DRAIN PIPE THRU COLUMN WHERE OCCURS - COORDINATE CONNECTION WITH CIVIL CONCRETE DRIVE SLAB AT CAR CANOPY - SEE CIVIL HEAT TAPE - SEE ELECTRICAL 18" DIA CIRCULAR FOOTING 6" DIA. STD. GALV. STEEL PIPE FILLED W/ CONCRETE (APPLY TWO COATS OF PAINT, EXACT COLOR TO BE DETERMINED BY OWNER) MIN. 0.188" WALL THICKNESS 02 02 02 02 SCALE: 1/8" = 1'-0" 1 FUEL CANOPY SCALE: 1/4" = 1'-0" 2 FUEL CANOPY SCALE: 1/2" = 1'-0" 3 COLUMN DRAIN DETAIL 12/21/2023 ID DATE DESCRIPTION 0002 10/11/23 12/21/23 Issue for AHJ Review ASI #1 Owner Changes STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL A -100 CIVIL 305 1st STREET, IDAHO FALLS,ID 83401 PH: 208.757.5700 22007 GOOD 2 GO 104 - REXBURG ID 1055 S 12th W REXBURG, ID 83440 FROST STRUCTURAL ENGINEERING 1020 LINCOLN RD IDAHO FALLS, ID 83401 PHONE: (208) 227-8404 Original document is on file with the date and architect signature Original documents signed by: 12/21/23 Date original documents signed: MUSGROVE ENGINEERING, P.A. 645 W. 25TH ST. IDAHO FALLS, ID 83402 PHONE: (208) 523-2862 THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. JONATHAN GALLUP MUSGROVE ENGINEERING 234 S. WHISPERWOOD WAY BOISE, ID 83709 PHONE: (208) 384-0585 CONNECT ENGINEERING 1150 HOLLIPARK DRIVE IDAHO FALLS, ID 83401 PHONE: (208) 681-8590 FIRST FLOOR PLAN PRELIMINARY FOR REVIEW NOT FOR CONSTRUCTION FLOOR PL AN GENERAL NOTES A. ALL DIMENSIONS ARE SHOWN TO THE FACE OF WALL FRAMING UNLESS SPECIFICALLY NOTED OTHERWISE B. HINGE SIDE OF DOOR SHALL BE LOCATED 4" TO INSIDE CORNER OF INTERSECTING WALLS UNLESS SPECIFICALLY NOTED OTHERWISE C. SEE G-105 FOR TYPICAL DETAILS PERTAINING TO STANDARD, GRAB BAR BACKING, DOOR STOP BACKING, RECESSED FIRE CABINETS AND STAGGERED OUTLET DETAILS. D. ITEMS TAGGED WITH A "O", "M", "DB", "FS", AND "PB" DESIGNATION ARE DEFINED ON THE EQUIPMENT FLOOR PLAN LOCATED ON SHEET A-102. FLOOR PL AN LEGEND ROOM NAME ROOM NUMBER FLOOR PLAN KEYNOTES A1 A2 A4 A6 A37 E1 E3 E5 E15 E16 P6 P15 RECESSED EMERGENCY KEY BOX WALL MOUNTED FIRE EXTINGUISHER ROOF ACCESS LADDER WITH LOCKABLE RAIL GUARD AT BASE RECESSED FIRE EXTINGUISHER DOOR OPERATION SWITCH - SEE ELECTRICAL ELECTRICAL METER, SEE ELECTRICAL TRANSFORMER SWITCHBOARD EMERGENCY FUEL SHUT OFF BUTTON - SEE ELECTRICAL FUEL MANAGEMENT SYSTEM MONITOR- SEE ELECTRICAL TELEPHONE TERMINAL BOARD - SEE ELECTRICAL GAS METER, SEE PLUMBING PLANS HOSEBIBB- SEE PLUMBING 831 sq ft 22 11 B B D D C C 33 F E E A A N J J 1. A-401 1. A-402 1. A-403 1. A-405 1. A-405 6 A-402 B1 A-571 B1 A-571 A1 A-511 B3 A-571 B1 A-572 B1 A-511 B1 A-511 B1 A-511 B3 A-511 4 A-201 3 A-201 2 A-201 1 A-201 4 A-301 4 A-301 1 A-301 1 A-301 2 A-301 2 A-301 #DrgID #LayID 5 A-301 5 A-301 3 A-301 3 A-301 6'-4" 5'-5 5/8" 5'-0" 5'-0" 2,176 sq ft A6 A2 P6P6 E3 E3 E3 E1 A2 A1 A4 E5 E5 E5 P15 A37 A37 E15 E16 P6 A1 A-571 B1 A-572 B1 A-511 A3 A-511 B1 A-501 A B 202106 301 B 104 110 A 113 103 A 103 B 102 200 A A 100 A AA 300 C 110 B B 100 B 300 A FREEZER 109 BEER 108 DISPLAY/PALLET 107 ELEC. 106 PACKAGE BEV 105 VESTIBULE 100 JAN. 113 WOMEN 112 MEN 111 OFFICE 103 KITCHEN 104 C-STORE 102 CIRCULATION 110 CIRCULATION 200 DINING 201 KITCHEN 202 POS 101 CIRCULATION 300 KITCHEN 301 02 02 02 02 SCALE: 1/8" = 1'-0"1 FIRST FLOOR PLAN 12/21/2023 ID DATE DESCRIPTION 0002 10/11/23 12/21/23 Issue for AHJ Review ASI #1 Owner Changes STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL A -104 CIVIL 305 1st STREET, IDAHO FALLS,ID 83401 PH: 208.757.5700 22007 GOOD 2 GO 104 - REXBURG ID 1055 S 12th W REXBURG, ID 83440 FROST STRUCTURAL ENGINEERING 1020 LINCOLN RD IDAHO FALLS, ID 83401 PHONE: (208) 227-8404 Original document is on file with the date and architect signature Original documents signed by: 12/21/23 Date original documents signed: MUSGROVE ENGINEERING, P.A. 645 W. 25TH ST. IDAHO FALLS, ID 83402 PHONE: (208) 523-2862 THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. JONATHAN GALLUP MUSGROVE ENGINEERING 234 S. WHISPERWOOD WAY BOISE, ID 83709 PHONE: (208) 384-0585 CONNECT ENGINEERING 1150 HOLLIPARK DRIVE IDAHO FALLS, ID 83401 PHONE: (208) 681-8590 FIRST FLOOR DIMENSION PLAN PRELIMINARY FOR REVIEW NOT FOR CONSTRUCTION DIMENSIONED PL AN GENERAL NOTES A. ALL DIMENSIONS ARE SHOWN TO THE FACE OF WALL FRAMING UNLESS SPECIFICALLY NOTED OTHERWISE B. HINGE SIDE OF DOOR SHALL BE LOCATED 4" TO INSIDE CORNER OF INTERSECTING WALLS UNLESS SPECIFICALLY NOTED OTHERWISE C. CRITICAL DIMENSIONS ARE SHOWN. IF DIMENSIONS ARE NOT INDICATED WITHIN A STRING OF DIMENSIONS, THE MISSING DIMENSION IS THE DESIRED SEGMENT THAT CAN ALLOW FOR SLIGHT ADJUSTMENTS IN LENGTH. 831 sq ft 22 11 B B D D C C 33 E E A A 15'-0"74'-1 1/2"23'-8"40'-10" 41'-0" 12'-0" 153'-7 1/2" 8'-4 1/2" 5'-6 1/2" 24'-0 1/2" 5'-6 1/2" 9'-6" 8'-0" 30'-4 1/2" 18'-4"18'-5"12'-5 1/2"16'-6"7'-5 3/4"7'-6 1/4" 2'-0" 18'-0 7/8"12'-11" 11'-10" 6 1/2" 5'-2"4'-4"10'-8"11'-4 1/2"13'-7"31'-0"23'-10" 1'-11 1/2" 6'-10" 9'-9" 3'-6"9'-3" 6" 12'-8 1/2" 13'-0 1/2" 8'-2" 8" 8'-2" 6'-0"10'-11"6'-3 1/2" 7'-9"9'-1 1/2"8'-0"7'-11"5'-0" 1'-9" 9'-7 1/2" 1'-9 1/4" 15'-0"44'-0"15'-4 3/4" 1'-8 1/2" 7'-6" 7'-4 25/64" 2'-8 3/4" 4'-6"7'-6"7'-0"10'-0" 3'-6" 4'-9" 11'-6" 2,176 sq ft E.Q. E.Q. E.Q. E.Q. 53'-0" 5'-5 1/2" 2'-7" 15'-8 1/4" 4'-9" 6'-4 11/16" 2'-1 1/2"2'-5 1/2" 2'-3 1/2" 3'-6" 10'-4 1/2"2'-4"20'-8"16'-7" W4-Fsh CS4-P W6-TF W6-TF W6-Fsh* W4-FTsh W4-P* W4-F W4-F W6-TF W4-F CS4-P W6-P W6-TF XSH-W6-T A B 202106 301 B 104 110 A 113 103 A 103 B 102 200 A A 100 A AA 300 C 110 B B 100 B 300 A 5'-3 1/2"4'-3 1/2"5'-0"4'-0"4'-7 1/2" 5'-6 1/2" CLEAR 30'-1 1/2" 7'-7" 11'-10 1/2" CS4-P* CS4-P CS6-P CS6-P W4-TF W4-T W4-T W6-TF W4-F W4-FTsh W4-T W4-T W4-T W4-F W4-F CS4-P CS4-P W4-FTsh W6-TF W4-TF W4-T W4-F CS4-P* CS4-P* CS6-P* CS6-P CS4-P W6-Fsh CS4-P* W6-T* W4-F* W4-F XSH-W8T XSH-W6-T XSH-W6-T XSH-W6-T XSH-W6-T XSH-W6-T XSH-W6-T XSH-W6-T XSH-W6-T XSH-W6-T XSH-W6-T XSH-W6-T XSH-W6-T XSH-W6-T XSH-W8T XSH-W8T XSH-W6-T W4-F* W4-F* W4-F* W4-F* FREEZER 109 BEER 108 DISPLAY/PALLET 107 ELEC. 106 PACKAGE BEV 105 VESTIBULE 100 JAN. 113 WOMEN 112 MEN 111 OFFICE 103 KITCHEN 104 C-STORE 102 CIRCULATION 110 CIRCULATION 200 DINING 201 KITCHEN 202 POS 101 CIRCULATION 300 KITCHEN 301 X-W6F1 S3F2-S FRAMED ASSEMBLIES LEGEND PREFIX -MATERIAL THICKNESS FIRE RATING X Exterior Wall C Concrete S Steel W Wood M Masonr y E LSL F.5 0.5 hours F1 1 hours F2 2 hours F3 3 hours NOTE 1.ASSEMBLIES WITHOUT A PREFIX ARE TO BE INTERIOR WALLS. 2."THICKNESS" TO BE THE NOMINAL SIZE INDICATED IN THE ASSEMBLIES TYPE. 3. ALL WALLS ARE TO BE FULL HEIGHT UNLESS NOTED OTHERWISE 4. CS4.-P* = GYP. BD. ON FINISH SIDE OF COOLER SYSTEM WALL ASSEMBLY ONLY, BACK SIDE OF COOLER WALL SYSTEM IS GALVANIZED ALUMINUM AND BACK SIDE OF PARTIAL HEIGHT WALL ABOVE COOLER IS OPEN STUD WALL CAVITY. 5. WALL TYPE WITH "*" PREFIX WILL HAVE GYPSUM ONLY ONE SIDE. *PARTIAL HEIGHT WALL TO BE 6" ABOVE FINISHED CEILING UNLESS INDICATED OTHERWISE - SUFFIX S Sound Insulation EXAMPLES: EXTERIOR WOOD FRAMED 2X6 SHEAR WALL, 1HR FIRE RATING INTERIOR STEEL FRAMED 3.625" STUD, 2HR FIRE RATING, SOUND INSULATION T Thermal Insulation P Partial Height sh Sheathing Wood Steel 3 (2 1/2") 4 (3 1/2") 6 (5 1/2") 8 (7 1/4") 2 162 (1 5/8") 3 250 (2 1/2") 4 362 (3 5/8") C Ceilings 6 600 (6") 8 800 (8") 10 1000 (10") 10 (9 1/4") 12 (11 1/4") 2 (1 1/2") FRAMING T YPE & THIC KNESS CS=Cooler System F Full Height DIMENSION PLAN KEYNOTES 02 0202 02 SCALE: 1/8" = 1'-0" 1 FIRST FLOOR DIMENSION PLAN 12/21/2023 ID DATE DESCRIPTION 0002 10/11/23 12/21/23 Issue for AHJ Review ASI #1 Owner Changes STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL A -150 CIVIL 305 1st STREET, IDAHO FALLS,ID 83401 PH: 208.757.5700 22007 GOOD 2 GO 104 - REXBURG ID 1055 S 12th W REXBURG, ID 83440 FROST STRUCTURAL ENGINEERING 1020 LINCOLN RD IDAHO FALLS, ID 83401 PHONE: (208) 227-8404 Original document is on file with the date and architect signature Original documents signed by: 12/21/23 Date original documents signed: MUSGROVE ENGINEERING, P.A. 645 W. 25TH ST. IDAHO FALLS, ID 83402 PHONE: (208) 523-2862 THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. JONATHAN GALLUP MUSGROVE ENGINEERING 234 S. WHISPERWOOD WAY BOISE, ID 83709 PHONE: (208) 384-0585 CONNECT ENGINEERING 1150 HOLLIPARK DRIVE IDAHO FALLS, ID 83401 PHONE: (208) 681-8590 FIRST FLOOR RCP PRELIMINARY FOR REVIEW NOT FOR CONSTRUCTION OFFICE 108 95 SF CLG 10' CEILING HEIGHT SQUARE FOOTAGE ROOM NUMBER CEILING PL AN GENERAL NOTES A. SEE B2/G-105 & B1/G-105 FOR TYPICAL CEILING GRID DETAILS B. ITEMS TAGGED WITH A "M", "PB", "DB", "FS", AND "O" DESIGNATION ARE DEFINED ON THE EQUIPMENT FLOOR PLAN LOCATED ON SHEET A-102 CEILING PL AN LEGEND GYPSUM BOARD CEILING 2'X4' ACCOUSTICAL CEILING TILE SUSPENDED PENDANT, SEE ELECTRICAL EXHAUST VENT, SEE MECHANICAL SUPPLY DIFFUSER, SEE MECHANICAL RETURN VENT, SEE MECHANICAL COLD STORAGE ROOMS LINEAR SURFACE MOUNT, SEE ELECTRICAL RECESSED 2'X4' TROFFER, SEE ELECTRICAL LINEAR PENDANT, SEE ELECTRICAL ROOF TRUSS - PT-4 (REF. FINISH PL AN), SEE STRUCTURAL OPEN TO STRUCTURE ABOVE RCP KEYNOTES A20 A21 A23 A23 A35 Q1 SUNSHADE EXIT SIGN OR DIRECTIONAL EXIT SIGN PER PLANS, PROVIDE POWER - SEE ELECTRICAL SIGN PACKAGE BY OWNER SIGN PACKAGE BY OWNER SUSPENDED CEILING CABLE PENETRATION SYSTEM PLATE SPEAKER O.F.O.I - SEE ELEC FOR CONDUIT ROUGH IN E.Q. E.Q. 831 sq ft 22 11 B B D D C C 33 E E A A J J A2 A-511 4 A-201 3 A-201 2 A-201 1 A-201 4 A-301 4 A-301 1 A-301 1 A-301 2 A-301 2 A-301 5 A-301 5 A-301 3 A-301 3 A-301 B1 A-521 10'-0" E.Q. E.Q. E.Q. E.Q. E.Q. E.Q. 1'-6" 2,176 sq ft Q1 Q1 Q1 Q1 Q1 Q1 Q1 Q1Q1 A21 A23 A23A23 A23A23 A4 A21 A23 A20 A20A20A20 A21 A35 Q1 Q1 C C C C C C C B2 G-105 A2 A-521 B2 A-521 B1 A-521 A3 A-521 A4 A-521 8'-0"8'-0" 7'-0 3/4" 7'-5 1/4" 9'-3 1/2" 9'-3 1/2" 3'-6" Q1 Q1 Q1 Q1 FREEZER 109 CLG 8'-0" BEER 108 CLG 8'-0" DISPLAY/PALLET 107 CLG 8'-0" ELEC. 106 CLG OPEN PACKAGE BEV 105 CLG 8'-0" VESTIBULE 100 CLG 14'-0" JAN. 113 CLG OPEN WOMEN 112 CLG 10'-0" MEN 111 CLG 10'-0" OFFICE 103 CLG 10'-0" KITCHEN 104 CLG 10'-0" C-STORE 102 CLG OPEN CIRCULATION 110 CLG OPEN CIRCULATION 200 CLG OPEN DINING 201 CLG OPEN KITCHEN 202 CLG OPEN POS 101 CLG OPEN CIRCULATION 300 CLG OPEN KITCHEN 301 CLG OPEN 02 SCALE: 1/8" = 1'-0"1 FIRST FLOOR 12/21/2023 ID DATE DESCRIPTION 0002 10/11/23 12/21/23 Issue for AHJ Review ASI #1 Owner Changes STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL A -201 CIVIL 305 1st STREET, IDAHO FALLS,ID 83401 PH: 208.757.5700 22007 GOOD 2 GO 104 - REXBURG ID 1055 S 12th W REXBURG, ID 83440 FROST STRUCTURAL ENGINEERING 1020 LINCOLN RD IDAHO FALLS, ID 83401 PHONE: (208) 227-8404 Original document is on file with the date and architect signature Original documents signed by: 12/21/23 Date original documents signed: MUSGROVE ENGINEERING, P.A. 645 W. 25TH ST. IDAHO FALLS, ID 83402 PHONE: (208) 523-2862 THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. JONATHAN GALLUP MUSGROVE ENGINEERING 234 S. WHISPERWOOD WAY BOISE, ID 83709 PHONE: (208) 384-0585 CONNECT ENGINEERING 1150 HOLLIPARK DRIVE IDAHO FALLS, ID 83401 PHONE: (208) 681-8590 EXTERIOR ELEVATIONS PRELIMINARY FOR REVIEW NOT FOR CONSTRUCTION 1 2 3 B3 A-501 A1 A-502 4'-0" B.O. ROWLOCK SILL 17'-6" 3'-0" 0" 20'-0" 27'-9" 7'-0"7'-0" E.Q.E.Q. A20 M23 M22 M21 B B BUILDING ELEVATION LEGEND BRICK - RUNNING BOND, GENERAL SHALE OLD THUNDERCLOUD, REF. 04 26 00 VESTA STEEL PLANK SYSTEM, SINGLE 6" DUTCH LAP, 480 AUTUMN THISTLE SIDING, SEE SPECS 07 42 13 - PROVIDE AND INSTALL SOLID BACKING WHERE DISPLAY SCREEN IS MOUNTED TO BUILDING. SIDING IS CONTINUOUS BEHIND DISPLAY UNIT. WHITE STUCCO PURE WHITE, 07 24 00 PARAPET STUCCO FINISH: URBANE BRONZE SW 7048 LIGHTS, SEE ELECTRICAL BUILDING ELEVATION KEYNOTES A1 A25 A30 A31 A36 E1 E3 E5 E12 E13 M20 M21 M22 M24 P6 P12 P15 Q2 <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> 26 00 00 Electrical 26 00 00 Electrical 26 00 00 Electrical <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> <Undefined> 22 00 00 Plumbing <Undefined> <Undefined> <Undefined> RECESSED EMERGENCY KEY BOX EMERGENCY FUEL SHUT OFF SIGN, SEE DETAIL C4/G-105 BOLLARD CONTROL JOINT SHELF, PROVIDE BLOCKING - O.F.O.I ELECTRICAL METER, SEE ELECTRICAL TRANSFORMER SWITCHBOARD EMERGENCY FUEL SHUT OFF BUTTON - SEE ELECTRICAL EXTERIOR LIGHT FIXTURE TYP., SEE ELECTRICAL EXTERIOR WALL LIGHTING TYP., SEE ELECTRICAL ICE MERCHANDISER FIREWOOD DISPLAY PROPANE CAGE EXTERIOR STORAGE RACK GAS METER, SEE PLUMBING PLANS DOWNSPOT NOZZLE - SEE PLUMBING HOSEBIBB- SEE PLUMBING SIGN, PROVIDE POWER 3 2 1 B3 A-501 C3 A-501 A1 A-502 4'-0" B.O. ROWLOCK SILL 17'-6" 20'-0" 10'-5" SUNSHADE HEIGHT 27'-9" 7'-0" 10'-0"11'-0"11'-0" A20 A4 M23 B A3 A-501 B1 A-501 E D C B A B3 A-501 C3 A-501 A1 A-502 4'-0" B.O. ROWLOCK SILL 17'-6" 18'-11" T.O. PARAPET 2'-0"MIN. 2'-0"MIN. 11'-0"11'-0"11'-0"11'-0"10'-4"10'-0"10'-0"10'-0"10'-0"7'-10 1/2"10'-0"10'-0"8'-2"7'-0" 202 106 E3 P6P6 104 111 A4 E5 P15 100 C P17P17 A31 P12 P12 B3 A-501 B C D EA C4 G-105B3 A-501 A1 A-511 B1 A-501 B3 A-511C4 G-105 B3 A-501 17'-6" 4'-0" B.O. ROWLOCK SILL 3'-6" 20'-0" 22'-10" SIGN HEIGHT 13'-0" SIGN HEIGHT 6' 11" 1'-3" 12'-8"12'-8"12'-8"12'-8"12'-8" A25A1 M20M21M22 A A A A A 200 Q2 Q2 M24 E5 E5 A25 Q4 M23 M23 A30 Q4 100 B 300 A C3 A-501 B3 A-501 02 02 02 0202 SCALE: 1/8" = 1'-0"4 EAST ELEVATION SCALE: 1/8" = 1'-0"3 WEST ELEVATION SCALE: 1/8" = 1'-0"2 SOUTH ELEVATION SCALE: 1/8" = 1'-0"1 NORTH ELEVATION 12/21/2023 ID DATE DESCRIPTION 0002 10/11/23 12/21/23 Issue for AHJ Review ASI #1 Owner Changes STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL A -401 CIVIL 305 1st STREET, IDAHO FALLS,ID 83401 PH: 208.757.5700 22007 GOOD 2 GO 104 - REXBURG ID 1055 S 12th W REXBURG, ID 83440 FROST STRUCTURAL ENGINEERING 1020 LINCOLN RD IDAHO FALLS, ID 83401 PHONE: (208) 227-8404 Original document is on file with the date and architect signature Original documents signed by: 12/21/23 Date original documents signed: MUSGROVE ENGINEERING, P.A. 645 W. 25TH ST. IDAHO FALLS, ID 83402 PHONE: (208) 523-2862 THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. JONATHAN GALLUP MUSGROVE ENGINEERING 234 S. WHISPERWOOD WAY BOISE, ID 83709 PHONE: (208) 384-0585 CONNECT ENGINEERING 1150 HOLLIPARK DRIVE IDAHO FALLS, ID 83401 PHONE: (208) 681-8590 ENLARGED PLANS PRELIMINARY FOR REVIEW NOT FOR CONSTRUCTION ENLG. PL AN & INT. ELEVATION GENERAL NOTES A. TILE MOVEMENT JOINTS REQUIRED AS INDICATED BELOW INTERIOR - MAX. 25 FT EACH DIRECTION EXTERIOR - 8-12 FT EACH DIRECTION INTERIOR TILE WORK EXPOSED TO SUNLIGHT - MAX. 12 FT EACH DIRECTION ABOVE-GROUND CONCRETE SLAB SUBTRATE - MAX. 12 FT EACH DIRECTION B. TOILET ROOMS ARE REQUIRED TO HAVE A SMOOTH, HARD NONABSORBENT SURFACE THAT EXTENDS AT LEAST 4 INCHES ONTO WALLS. C. REFER TO AF-100 SERIES SHEET FOR FLOOR FINISH SCHEDULE FOR WALL, BASE, CEILING AND FLOOR FINISHES. D. CASEWORK CONFIGURATIONS ARE PER ARCHITECTURAL WOODWORK INSTITUTE (AWI). E. TILE LAYOUT SHOULD START (1) ONE FULL TILE HEIGHT ABOVE THE FLOOR, ANY CUTTING THAT NEEDS TO HAPPEN SHALL BE CUT FROM THE BOTTOM TILE COURSE. 5 3 6 4 5 A-401 7 10 9 8 7 A-401 2 2 A-401 13 12 13 A-401 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 7'-0" 1'-0" 3'-6"1'-0"3'-6" P11 P11 P11 P11 P11 P11 P11 P11 P11 P11 P11 P11 A15 A15 A15 A15 A15 A15 A15 A15 A15 A15 A15 A15 P12P12P10 P10 P10 P10 P10 A15 A17 A17 A17A17 A17 A17 A17 A17 P13P12 P9 A17A17 A24 A13 A13 A18A18 A18A18 A18A18 A18A18 P14 A26 A26 P11 P14 A16 A16 A16 A16 A16 A16 A16 A16 A24A24 A24A24 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 16" MIN 5'-6" 3'-0" 3'-0" A24 PB4 PB4 PB4 PB11 PB11 PB11 M30 A24 A24 A16 A24A24 A29 JAN. 113 WOMEN 112 MEN 111 1'-0" 5'-6" 1'-0" 6" 7'-0" 7'-0" 6" PT-2 B-1 ST-2 ST-2 DB1 14'-0" 2'-10" ALIGN TO CEILING 6'-0" A17 A18 A18 A18 A18 A17 A17A17 CT-1 PT-1 TL-1 A26 PT-1 TL-2 P14 6'-0" 2'-0" TYP. 1'-5" P10 P10 P10 P10 P10 P11 P11 P11 P11 A13 A15 A24 A15A15A15 A13 A13 A13A13A13A13 PT-1 TL-1 A24A13A24A24A24 6'-0" P11 A24 A15 A13 A26 PT-1 TL-1A24A24 6'-0" 2'-0" P10 A13 A17 A18 P14 TL-1 PT-1 CT-1 ST-2 ST-1 6'-0" A13 A15A26 TL-1 PT-1 P11 A16 A24A24A24 14'-0" 2'-10" ALIGN TO CEILING 6'-0" A17 A17 A17 A17 A18 A18A18A18 A26TL-1 PT-1 TL-2 PT-1 CT-1 P14 6'-0" P11 A17 A13 A18 PT-1 TL-1 CT-1 P14 ST-2 ST-1 6'-0" P11 P11 P11 P11 P11 P11 P11 P11 A15 A15 A15 A15 A15 A15 A15 A15 A15 A13 A13 A13 A13 A13 A13 A13 A13 TL-1 PT-1 A24 P11 A24A24A24 A24 RR KEYNOTES A13 A15 A16 A17 A18 A24 A26 A29 E20 P9 P10 P11 P12 P13 P14 10 21 13 10 28 13 10 28 13 10 28 13 <Undefined> 10 28 13 <Undefined> <Undefined> <Undefined> 22 00 00 22 00 00 22 00 00 22 00 00 22 00 00 12 36 00 TOILET PARTITION TOILET PAPER DISPENSER SANITARY NAPKIN DISPOSAL UNIT - O.F.C. PAPER TOWEL DISPENSER MIRROR VERTICAL, REAR, AND HORIZONTAL GRAB BARS BABY CHANGING STATION - O.F.O.I WALL- MOUNTED MOP / BROOM HOLDER WITH SHELF - PROVIDE AND INSTALL SOLID BLOCKING RECESSED LIGHT, SEE ELECTRICAL FLOOR SINK 2'x2', SEE PLUMBING URINAL, SEE PLUMBING TOILET, SEE PLUMBING FLOOR DRAIN - SEE PLUMBING HOT WATER BOILER - SEE PLUMBING SINK - SEE PLUMBING 10" 6'-7 3/4" WL-1 P13 WL-1 3'-5" 6'-7" WL-1 WL-1 P13 02 SCALE: 1/4" = 1'-0" 1 RR ENLARGED PLANS SCALE: 1/4" = 1'-0" 2 CIRCULATION SCALE: 1/4" = 1'-0" 3 RR MEN SCALE: 1/4" = 1'-0" 4 RR MEN SCALE: 1/4" = 1'-0" 5 RR MEN SCALE: 1/4" = 1'-0" 6 RR MEN SCALE: 1/4" = 1'-0" 7 RR WOMEN SCALE: 1/4" = 1'-0" 8 RR WOMEN SCALE: 1/4" = 1'-0" 9 RR WOMEN SCALE: 1/4" = 1'-0" 10 RR WOMEN SCALE: 1/4" = 1'-0"13 Janitor Room SCALE: 1/4" = 1'-0"12 Janitor Room 12/21/2023 ID DATE DESCRIPTION 0002 10/11/23 12/21/23 Issue for AHJ Review ASI #1 Owner Changes STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL A -403 CIVIL 305 1st STREET, IDAHO FALLS,ID 83401 PH: 208.757.5700 22007 GOOD 2 GO 104 - REXBURG ID 1055 S 12th W REXBURG, ID 83440 FROST STRUCTURAL ENGINEERING 1020 LINCOLN RD IDAHO FALLS, ID 83401 PHONE: (208) 227-8404 Original document is on file with the date and architect signature Original documents signed by: 12/21/23 Date original documents signed: MUSGROVE ENGINEERING, P.A. 645 W. 25TH ST. IDAHO FALLS, ID 83402 PHONE: (208) 523-2862 THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. JONATHAN GALLUP MUSGROVE ENGINEERING 234 S. WHISPERWOOD WAY BOISE, ID 83709 PHONE: (208) 384-0585 CONNECT ENGINEERING 1150 HOLLIPARK DRIVE IDAHO FALLS, ID 83401 PHONE: (208) 681-8590 ENLARGED PLANS PRELIMINARY FOR REVIEW NOT FOR CONSTRUCTION ENLG. PL AN & INT. ELEVATION GENERAL NOTES A. TILE MOVEMENT JOINTS REQUIRED AS INDICATED BELOW INTERIOR - MAX. 25 FT EACH DIRECTION EXTERIOR - 8-12 FT EACH DIRECTION INTERIOR TILE WORK EXPOSED TO SUNLIGHT - MAX. 12 FT EACH DIRECTION ABOVE-GROUND CONCRETE SLAB SUBTRATE - MAX. 12 FT EACH DIRECTION B. TOILET ROOMS ARE REQUIRED TO HAVE A SMOOTH, HARD NONABSORBENT SURFACE THAT EXTENDS AT LEAST 4 INCHES ONTO WALLS. C. REFER TO AF-100 SERIES SHEET FOR FLOOR FINISH SCHEDULE FOR WALL, BASE, CEILING AND FLOOR FINISHES. D. CASEWORK CONFIGURATIONS ARE PER ARCHITECTURAL WOODWORK INSTITUTE (AWI). E. TILE LAYOUT SHOULD START (1) ONE FULL TILE HEIGHT ABOVE THE FLOOR, ANY CUTTING THAT NEEDS TO HAPPEN SHALL BE CUT FROM THE BOTTOM TILE COURSE. F 6 A-402 788 A-403 4 6 5 4 A-403 322 A-403 FS22 FS25 FS27 FS23 FS24 FS25 FS24 FS26 FS29 M30 DB6 P8P7 FS20 DB5 DB5 M30 DB3 DB3 DB4 O15 O13 DB7 O11 O4 O12 P8 P7 A3 A3 A3 M30 M30 A2 FS30 P4 P7 O16 A35 A1 A-571 FS28 P8 O10 O14 OFFICE 103 KITCHEN 104 4'-3"2'-0" 2'-10" 3'-2" O14 O10O4 O13 O11 O12 PT-2 B-1 7'-0" ALIGN TO CEILING O15 O16B-1 PT-2 FS29FS28FS26 FS24 FS25 FS23 WL-1 B-2 104 WL-1 B-2 ST-2 FS25 FS24 FS23DB6FS20 A2 FS27 B-2 WL-1 M30 ST-1 102 WL-1 M30 103 B DB7 WL-1 WL-1 DB3 DB4 7'-0" P4 FS30 WL-1 B-2 CO OL ER ST-2 KITCHEN KEYNOTES A2 A3 A22 A35 DB1 DB2 DB3 DB4 DB5 DB6 DB7 FS20 FS22 FS23 FS24 FS25 FS26 FS27 FS28 FS29 FS30 M30 O4 O10 O11 O12 O13 O14 O15 O16 P4 P7 P7 <Undefined> <Undefined> <Undefined> <Undefined> - - - - - - - <Undefined> - <Undefined> - - - - <Undefined> 22 00 00 <Undefined> - - - - <Undefined> - - - <Undefined> <Undefined> <Undefined> 22 00 00 WALL MOUNTED FIRE EXTINGUISHER SELF SERVICE COUNTERTOP CASE PLASTIC CUP DISPENSER, O.F.O.I. SUSPENDED CEILING CABLE PENETRATION SYSTEM PLATE FOUNTAIN - IDC PRO FOUNTAIN - CORNELIUS 12 HEAD FOUNTAIN BIB RACK FOUNTAIN CO2 TANK ICE MAKER ICE MAKER - BULK/BAGGER WATER FILTRATION SYSTEM FREEZER - 2 DOOR REACH IN SPEED OVEN MICROWAVE PREP TABLE W/ FRIDGE UNDER STAINLESS STEEL WORK TABLE, O.F.O.I. DRYING RACK ELECTRIC DROP DOWN 3-COMPARTMENT SINK, SEE PLUMBING HAND SINK, SEE PLUMBING. MOP SINK, SEE PLUMBING STORAGE RACKS PHONE COMPUTER & MONITOR PRINTER CHAIR FILE CABINET - 2 DRAWERS SAVI TV MONITOR DATA RACK - WALL MOUNTED MUSIC AND CAMERAS WATER HEATER, SEE PLUMBING FLOOR DRAIN - SEE PLUMBING FLOOR DRAIN - SEE PLUMBING 9'-0" FS24 FS26 FS27 FS25 M30 DB2 DB2 A3 A3 A3 A3 WL-1 B-2 ST-2FS29 FS28 FS20 DB6 P4 FS30 ST-2 B-2 WL-1WL-1 DB1 DB1 DB5 DB5 A22 CT-1 DB4 DB7 DB3 DB3 M30 FS22 FS23 FS24 FS25 FS24 M30 M30 WL-1 B-2 02 SCALE: 1/4" = 1'-0" 1 KITCHEN ENLARGED PLAN SCALE: 1/4" = 1'-0" 2 OFFICE E SCALE: 1/4" = 1'-0" 3 OFFICE W SCALE: 1/4" = 1'-0" 4 KITCHEN S SCALE: 1/4" = 1'-0" 5 KITCHEN N SCALE: 1/4" = 1'-0" 6 KITCHEN W SCALE: 1/4" = 1'-0" 7 KITCHEN W SCALE: 1/4" = 1'-0" 8 KITCHEN E 12/21/2023 ID DATE DESCRIPTION 0002 10/11/23 12/21/23 Issue for AHJ Review ASI #1 Owner Changes STRUCTURAL MECHANICAL / PLUMBING ELECTRICAL CIVIL A -521 305 1st STREET, IDAHO FALLS,ID 83401 PH: 208.757.5700 22007 GOOD 2 GO 104 - REXBURG ID 1055 S 12th W REXBURG, ID 83440 FROST STRUCTURAL ENGINEERING 1020 LINCOLN RD IDAHO FALLS, ID 83401 PHONE: (208) 227-8404 Original document is on file with the date and architect signature Original documents signed by: 12/21/23 Date original documents signed: MUSGROVE ENGINEERING, P.A. 645 W. 25TH ST. IDAHO FALLS, ID 83402 PHONE: (208) 523-2862 THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. THESE PLANS, DRAWINGS, AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF RESIN ARCHITECTURE, LLC AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN CONSENT. ALL RIGHTS RESERVED © 2023 RESIN ARCHITECTURE, LLC. JONATHAN GALLUP MUSGROVE ENGINEERING 234 S. WHISPERWOOD WAY BOISE, ID 83709 PHONE: (208) 384-0585 CONNECT ENGINEERING 1150 HOLLIPARK DRIVE IDAHO FALLS, ID 83401 PHONE: (208) 681-8590 CEILING DETAILS PRELIMINARY FOR REVIEW NOT FOR CONSTRUCTION 07 46 16 Steel Siding 06 10 00 Wood Sheathing 06 10 00 & 07 21 26 Wood Framing + Insulation Wood - Structural - R-22 Min. Blow-in Insulation 09 21 16 Gypsum Board 09 21 16 Gypsum Board 06 11 00 Framing Lumber Wood - Structural 09 21 16 Gypsum Board 13 21 26 Cold Storage Rooms 06 10 00 Plywood 06 10 00 & 07 21 26 Wood Framing + Insulation Wood - Structural - Batt Insulation 2X6 Insulated Wood Framing 06 11 00 Framing Lumber Wood - Structural 09 21 16 Gypsum Board 09 21 16 Gypsum Board 06 11 00 Framing Lumber Wood - Structural 9'-0" WALL ASSEMBLY 0'-0 5/8" Gypsum Board 0'-3 1/2" Wood - Structural WALL ASSEMBLY 0'-0 1/8" 60 Mil. TPO Roofing Membrane 0'-7" R-30 Insulation - Foam Board 0'-0 3/4" Wood - OSB ROOF SHEATHING TO EXTEND FROM BOTTOM SUSPENDED WALL TO TOP OF TOP 7 CHORD OF TRUSS, SEE STRUCTURAL MDF 7'-0" <ID> Wood - Structural Gypsum Board Cold Storage Rooms Gypsum Board Wood - Structural Wood - Sheathing 6" 06 11 00 Framing Lumber Wood - Structrural Roof Structure 09 21 16 Gypsum Board09 21 16 Gypsum Board 6'-7" 3'-6" 2" MIN P13 FLOOR ASSEMBLY 0'-0 3/4" Wood - Sheathing 0'-9 1/2" Air Space 0'-0 1/2" Gypsum Board 0'-0 1/2" FRP Wall Panel Wood Structural @ 16"O.C FRP 02 SCALE: 1" = 1'-0"A1 EXT. VESTIBULE WALL @ CEILING SCALE: 1" = 1'-0" B1 GYP. @ COOLER SCALE: 1/2" = 1'-0" B2 SUSPENDED CEILING SCALE: 1/2" = 1'-0" A2 SUSPENDED WALL SCALE: 1/2" = 1'-0" A3 CEILING @ WATER HEATER SCALE: 3/4" = 1'-0" C3 SUSPENDED CEILING @ C-STORE SCALE: 1/2" = 1'-0"A4 CEILING @ JANITOR 12/21/2023